Sample records for sealant package insert

  1. Glass ionomer ART sealants in Chinese school children-6-year results.

    PubMed

    Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu

    2013-09-01

    To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. 40 CFR 63.5110 - What special definitions are used in this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... include, but are not limited to, paints, varnishes, sealants, inks, adhesives, maskants, and temporary..., including properties that are separated only by a road or other public right-of-way. Flexible packaging...

  3. 40 CFR 63.5110 - What special definitions are used in this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... include, but are not limited to, paints, varnishes, sealants, inks, adhesives, maskants, and temporary..., including properties that are separated only by a road or other public right-of-way. Flexible packaging...

  4. 40 CFR 63.5110 - What special definitions are used in this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... include, but are not limited to, paints, varnishes, sealants, inks, adhesives, maskants, and temporary..., including properties that are separated only by a road or other public right-of-way. Flexible packaging...

  5. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for estrogens. 310.515... package inserts for estrogens. (a) Requirement for a patient package insert. FDA concludes that the safe... patient package insert containing information concerning the drug's benefits and risks. An estrogen drug...

  6. [The development and operation of a package inserts service system for electronic medical records].

    PubMed

    Yamada, Hidetoshi; Nishimura, Sachiho; Shimamori, Yoshimitsu; Sato, Seiji; Hayase, Yukitoshi

    2003-03-01

    To promote the appropriate use of pharmaceuticals and to prevent side effects, physicians need package inserts on medicinal drugs as soon as possible. A medicinal drug information service system was established for electronic medical records to speed up and increase the efficiency of package insert communications within a medical institution. Development of this system facilitates access to package inserts by, for example, physicians. The time required to maintain files of package inserts was shortened, and the efficiency of the drug information service increased. As a source of package inserts for this system, package inserts using a standard generalized markup language (SGML) form were used, which are accessible to the public on the homepage of the Organization for Pharmaceutical Safety and Research (OPSR). This study found that a delay occurred in communicating revised package inserts from pharmaceutical companies to the OPSR. Therefore a pharmaceutical department page was set up as part of the homepage of the medical institution for electronic medical records to shorten the delay in the revision of package inserts posted on the medicinal drug information service homepage of the OPSR. The usefulness of this package insert service system for electronic medical records is clear. For more effective use of this system based on the OPSR homepage pharmaceutical companies have been requested to provide quicker updating of package inserts.

  7. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    PubMed

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (p<0.05) between the readability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  8. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  9. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  10. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Patient package inserts for oral contraceptives... Patient package inserts for oral contraceptives. (a) Requirement for a patient package insert. The safe and effective use of oral contraceptive drug products requires that patients be fully informed of the...

  11. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    NASA Astrophysics Data System (ADS)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  12. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].

    PubMed

    Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao

    2016-06-01

    To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P<0.05). No significant difference was found between C1 and C2 groups (P>0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P<0.05). The caries rate in A1and A2, B1 and B2, C1 and C2 group had no significant difference during different follow-up time (P>0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.

  13. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    PubMed

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  14. Use of a vessel sealant device for cystic duct ligation in the dog.

    PubMed

    Marvel, Sarah; Monnet, Eric

    2014-11-01

    To compare a vessel sealant device to hemostatic clips for cystic duct ligation in a canine cadaveric model. Experimental. Hepatobiliary systems were collected from normal dogs. A microtip pressure transducer was inserted into the common bile duct and a 20-24 g intravenous catheter was placed in a hepatic duct. The cystic duct was ligated with 1 of 3 techniques: vessel sealant device (VSD), 10 mm medium Endoclips™, or 10 mm large Endoclips™ with 6 specimens in each group. Methylene blue was infused until failure, which was recorded as seal/clip failure or retrograde movement of methylene blue into the liver. Mean failure pressure of the medium endoclip group was significantly lower than the large endoclip group (P = .014). There was no difference between the failure pressure of the VSD group and the medium and large endoclip groups (P = .097, P = .34, respectively). Failure by leakage at the cut surface of the cystic duct occurred in 2 specimens in the medium endoclip group while all others failed by retrograde flow of the methylene blue through the hepatic ducts. The vessel sealant device appears comparable to large endoclips for closure of the cystic duct in an acute cadaveric model, while medium endoclips may not fully compress or span the diameter of a cystic duct in large breed dogs and leak at lower pressures. © Copyright 2014 by The American College of Veterinary Surgeons.

  15. [A research of letter color visibility in package insert information using simulator].

    PubMed

    Kamimura, Naoki; Kinoshita, Noriyuki; Onaga, Midori; Watanabe, Yurika; Ijuin, Kazushige; Shikamura, Yoshiaki; Negishi, Kenichi; Kaiho, Fusao; Ohta, Takafumi

    2012-01-01

    Package insert of pharmaceutical drug is one of the most prioritized information for pharmacists to secure safety of patients. However, the color of character, size, font and so on are various company by company product to product from a viewpoint of visibility. It may be cause a serious accident in case visibility is unclear, although it is the most important information. Moreover, package insert with high visibility is required for color vision defectives from a viewpoint of a universal design. Then, the authors selected the package insert which has the boxed warning in the ethical pharmaceutical currently stored mostly in the present health insurance pharmacy and quantified the red color using the color meter. We advocate the state of a suitable package insert from a viewpoint of a universal design, whether the red color is high visible or not for color vision defectives using simulator.

  16. [Research on Insufficient Information for Pharmaceutical Products].

    PubMed

    Tomita, Takashi

    2017-01-01

     Several issues concerning medicines remain unclear, including the availability of known, but not easily recognizable information. This review evaluates the mechanisms of side effects and the various risk indications included in package inserts. The results can be summarized as follows. 1) Short-term exposure to gatifloxacin significantly induced insulin secretion and increased the cytosolic Ca 2+ concentration of islet cells by augmenting extracellular Ca 2+ influx and its release from the endoplasmic reticulum. Alternatively, there was a decline in the cellular insulin level and reactivity to sulfonylurea after prolonged exposure. The insulin depletion was greater than that produced by other fluoroquinolones. 2) The elution of di(2-ethylhexyl)phthalate (DEHP) from the infusion set could be associated with the solubilizers in the injection medicines. The package inserts of several products containing polysorbate or ethanol had no warning about DEHP. Although there was a slight correlation between polysorbate content and descriptions on package inserts, the use of DEHP-containing devices was prohibited for some products, even with limited amounts of polysorbate. Therefore, the package insert statements should be reviewed to reflect appropriately the extent of DEHP elution. 3) Risk management plan consists of strategies to minimize the potential risks of medicines. One approach could be to introduce reminders on package inserts; however, of 268 potential risks associated with 81 products, 56 were not mentioned in package inserts. Because most postmarketing pharmacovigilance plans depend on spontaneous reporting by healthcare personnel, the descriptions on package inserts should be reexamined.

  17. Painless treatment of hydrocele: EMLA cream anaesthesia and fibrin adhesive sclerotherapy.

    PubMed

    Cecchi, M; Sepich, C A; Pagni, G; Ippolito, C; Minervini, R; Fiorentini, L

    1997-01-01

    Sclerotherapy for hydroceles was performed in 18 patients. Cutaneous anaesthesia was induced with an anaesthetic cream (lidocaine and prilocaine, EMLA cream) and a fibrin sealant (Tissucol) was injected into the sac after fluid aspiration. Patients experienced no pain during needle insertion and sclerosant procedure; 2 recurrences were observed during follow-up. EMLA cream anaesthesia and fibrin adhesive sclerotherapy represent a useful alternative to surgical treatment of hydroceles.

  18. Development of low cost, high reliability sealing techniques for hybrid microcircuit packages. Phase 2, supplement 1: Moisture permeation of adhesive-sealed hybrid microcircuit packages

    NASA Technical Reports Server (NTRS)

    Perkins, K. L.; Licari, J. J.

    1978-01-01

    The susceptibility of adhesive-sealed ceramic packages to moisture permeation was investigated. The two adhesives, Ablebond 789-1 and Epo-Tek H77, were evaluated as package sealants. These adhesives were previously selected as the most promising candidates for this application from a group of ten adhesives. Ceramic packages sealed with these adhesives were exposed to temperature-humidity conditions of 25 C/98 percent RH, 50 C/60 percent RH, 50 C/98 percent RH, and 85 C/85 percent RH and their moisture contents using were monitored solid state moisture sensors sealed inside them. Five packages were tested at each of these exposures - two ceramic packages sealed with each of the two adhesives and one seam-sealed gold-plated Kovar package. This latter package was included to serve as a control. The results showed that the adhesive-sealed packages were not hermetic to moisture. The rates at which moisture entered the packages increased with the severity of the exposure environments (i.e., higher temperatures and higher moisture vapor pressures) with greater dependence on temperature than on moisture vapor pressure.

  19. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  20. Seal welded cast iron nuclear waste container

    DOEpatents

    Filippi, Arthur M.; Sprecace, Richard P.

    1987-01-01

    This invention identifies methods and articles designed to circumvent metallurgical problems associated with hermetically closing an all cast iron nuclear waste package by welding. It involves welding nickel-carbon alloy inserts which are bonded to the mating plug and main body components of the package. The welding inserts might be bonded in place during casting of the package components. When the waste package closure weld is made, the most severe thermal effects of the process are restricted to the nickel-carbon insert material which is far better able to accommodate them than is cast iron. Use of nickel-carbon weld inserts should eliminate any need for pre-weld and post-weld heat treatments which are a problem to apply to nuclear waste packages. Although the waste package closure weld approach described results in a dissimilar metal combination, the relative surface area of nickel-to-iron, their electrochemical relationship, and the presence of graphite in both materials will act to prevent any galvanic corrosion problem.

  1. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay; Ensor, Joe E.

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if themore » absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.« less

  2. Battery with modular air cathode and anode cage

    DOEpatents

    Niksa, Marilyn J.; Pohto, Gerald R.; Lakatos, Leslie K.; Wheeler, Douglas J.; Niksa, Andrew J.; Schue, Thomas J.

    1987-01-01

    A battery assembly of the consumable metal anode type has now been constructed for ready assembly as well as disassembly. In a non-conductive and at least substantially inert cell body, space is provided for receiving an open-structured, non-consumable anode cage. The cage has an open top for facilitating insertion of an anode. A modular cathode is used, comprising a peripheral current conductor frame clamped about a grid reinforced air cathode in sheet form. The air cathode may be double gridded. The cathode frame can be sealed, during assembly, with electrolyte-resistant-sealant as well as with adhesive. The resulting cathode module can be assembled outside the cell body and readily inserted therein, or can later be easily removed therefrom.

  3. Battery with modular air cathode and anode cage

    DOEpatents

    Niksa, Marilyn J.; Pohto, Gerald R.; Lakatos, Leslie K.; Wheeler, Douglas J.; Niksa, Andrew J.; Schue, Thomas J.; Turk, Thomas R.

    1988-01-01

    A battery assembly of the consumable metal anode type has now been constructed for ready assembly as well as disassembly. In a non-conductive and at least substantially inert cell body, space is provided for receiving an open-structured, non-consumable anode cage. The cage has an open top for facilitating insertion of an anode. A modular cathode is used, comprising a peripheral current conductor frame clamped about a grid reinforced air cathode in sheet form. The air cathode may be double gridded. The cathode frame can be sealed, during assembly, with electrolyte-resistant-sealant as well as with adhesive. The resulting cathode module can be assembled outside the cell body and readily inserted therein, or can later be easily removed therefrom.

  4. Method of making a unitized electrode assembly

    DOEpatents

    Niksa, Marilyn J.; Pohto, Gerald R.; Lakatos, Leslie K.; Wheeler, Douglas J.; Solomon, Frank; Niksa, Andrew J.; Schue, Thomas J.; Genodman, Yury; Turk, Thomas R.; Hagel, Daniel P.

    1988-01-01

    A battery assembly of the consumable metal anode type has now been constructed for ready assembly as well as disassembly. In a non-conductive and at least substantially inert cell body, space is provided for receiving an open-structured, non-consumable anode cage. The cage has an open top for facilitating insertion of an anode. A modular cathode is used, comprising a peripheral current conductor frame clamped about a grid reinforced air cathode in sheet form. The air cathode may be double gridded. The cathode frame can be sealed, during assembly, with electrolyte-resistant-sealant as well as with adhesive. The resulting cathode module can be assembled outside the cell body and readily inserted therein, or can later be easily removed therefrom.

  5. Method of making a unitized electrode assembly

    DOEpatents

    Niksa, M.J.; Pohto, G.R.; Lakatos, L.K.; Wheeler, D.J.; Solomon, F.; Niksa, A.J.; Schue, T.J.; Genodman, Y.; Turk, T.R.; Hagel, D.P.

    1988-12-06

    A battery assembly of the consumable metal anode type has now been constructed for ready assembly as well as disassembly. In a non-conductive and at least substantially inert cell body, space is provided for receiving an open-structured, non-consumable anode cage. The cage has an open top for facilitating insertion of an anode. A modular cathode is used, comprising a peripheral current conductor frame clamped about a grid reinforced air cathode in sheet form. The air cathode may be double gridded. The cathode frame can be sealed, during assembly, with electrolyte-resistant-sealant as well as with adhesive. The resulting cathode module can be assembled outside the cell body and readily inserted therein, or can later be easily removed therefrom. 6 figs.

  6. The Use of Cigarette Package Inserts to Supplement Pictorial Health Warnings: An Evaluation of the Canadian Policy.

    PubMed

    Thrasher, James F; Osman, Amira; Abad-Vivero, Erika N; Hammond, David; Bansal-Travers, Maansi; Cummings, K Michael; Hardin, James W; Moodie, Crawford

    2015-07-01

    Canada is the first country in the world to require cigarette manufacturers to enclose package inserts to supplement the exterior pictorial health warning label (HWL). In June 2012, Canada implemented new HWL package inserts that include cessation tips accompanied by a pictorial image. This study aims to assess the extent to which adult smokers report reading the newly mandated HWL inserts and to see whether reading them is associated with making a quit attempt. Data were analyzed from an online consumer panel of Canadian adult smokers, aged 18-64 years. Five waves of data were collected between September 2012 and January 2014, separated by 4-months intervals (n = 1,000 at each wave). Logistic generalized estimating equation (GEE) models were estimated to assess correlates of reading inserts and whether doing so is associated with making a quit attempt by the subsequent wave. At each wave, between 26% and 31% of the sample reported having read HWL package inserts at least once in the prior month. Smokers who read them were more likely to be younger, female, have higher income, intend to quit, have recently tried to quit, and thought more frequently about health risks because of warning labels. In models that adjusted for these and other potential confounders, smokers who read the inserts a few times or more in the past month were more likely to make a quit attempt at the subsequent wave compared to smokers who did not read the inserts. HWL package inserts with cessation-related tips and messages appear to increase quit attempts made by smokers. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    PubMed

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  8. Deficiencies of product labeling directions for the preparation of radiopharmaceuticals.

    PubMed

    Hung, Joseph C; Ponto, James A; Gadient, Katie R; Frie, Julia A; Aksamit, Carolyn M; Enquist, Cassandra L; Carrels, Katie E

    2004-01-01

    To identify potential deficiencies in product labeling (package insert) instructions for the preparation of radiopharmaceuticals. Preparation instructions, which include both reconstitution and quality control (QC) directions, as stated in the package inserts were evaluated for all commercially available reconstituted radiopharmaceuticals. Reviews of the package inserts were initially performed by each author, and then all identified deficiencies were compiled and evaluated by all authors. The preparation scenario for each package insert evaluated was based on a centralized nuclear pharmacy operation assuming typical support personnel, standard operating equipment, and workload. The instructions as stated in each package insert for the preparation (including QC) were rated as inadequate if a satisfactory preparation could not be prepared by a nuclear pharmacist or physician when instructions were followed exactly. Identified deficiencies in package insert instructions for the preparation of radiopharmaceuticals fell into the following five categories: (1) absent or incomplete directions (especially with regard to QC procedures); (2) restrictive directions (e.g., specific requirement to use designated needles, chromatography solvents, counting devices), (3) inconsistent directions (e.g., different reconstituted volumes for the same final drug product, unworkable expiration times); (4) impractical directions (e.g., unrealistically low reconstituted activity limits, dangerously high number of radiolabeled particles); and (5) vague directions (e.g., use of the words "should," "may," "recommend"). Manufacturers' directions for the preparation of radiopharmaceuticals often contain deficiencies and should be viewed as standard guidance rather than as requirements. Just as physicians are permitted to use U.S. Food and Drug Administration (FDA)-approved drugs for off-label indications, nuclear pharmacists should be allowed to use alternative methods for preparing radiopharmaceuticals, provided those methods have been validated to be as good as the stated directions and that the nuclear pharmacists do not engage in activities that fall outside the normal practice of pharmacy. Manufacturers, FDA, nuclear pharmacists, and nuclear physicians should work together to address identified deficiencies in package insert directions.

  9. Dental sealants

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  10. [A comparative analysis of inner wrapping and package inserts for medicines containing Panax ginseng C. A. Meyer].

    PubMed

    Auricchio, Mariangela Tirico; Batistic-Longatto, Mônica Arcon; Nicoletti, Maria Aparecida

    2007-10-01

    The information provided on package inserts and inner wrapping of eight products containing Panax ginseng from different manufacturers was compared internally and checked against data from the scientific literature. The inserts included extensive text, containing abundant information on indications for use, but no scientific evidence in humans. All the inserts lacked information on potential adverse effects and drug interaction. There was no standardization as to dose regimens, particularly in relation to the dried extract and ginsenoside concentration. The eight inserts thus showed no concern over standardization, indication for usage, or possible side effects and drug interactions.

  11. Factors associated with sealant outcome in 2 pediatric dental clinics: a multivariate hierarchical analysis.

    PubMed

    West, Nathan G; Ilief-Ala, Melina A; Douglass, Joanna M; Hagadorn, James I

    2011-01-01

    This study's purpose was to determine whether one-time sealants placed by pediatric dental residents vs dental students have different outcomes. The effect of isolation technique, behavior, duration of follow-up, and caries history was also examined. Records from 2 inner-city pediatric dental clinics were audited for 6- to 10-year-old patients with a permanent first molar sealant with at least 2 years of follow-up. A successful sealant was a one-time sealant that received no further treatment and was sealed or unsealed but not carious or restored at the final audit. Charts from 203 children with 481 sealants were audited. Of these, 281 sealants were failures. Univariate analysis revealed longer follow-up and younger age were associated with sealant failure. Operator type, child behavior, and isolation technique were not associated with sealant failure. After adjusting for follow-up duration, increased age at treatment reduced the odds of sealant failure while a history of caries reduced the protective effect of increased age. After adjusting for these factors, practitioner type, behavior, and type of isolation were not associated with sealant outcome in multivariate analysis. Age at sealant placement, history of caries prior to placement, and longer duration of follow-up are associated with sealant failure.

  12. Sensitivity for Diagnosing Group A Streptococcal Pharyngitis from Manufacturers is 10% Higher than Reported in Peer-Reviewed Publications.

    PubMed

    Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A

    2017-01-01

    Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.

  13. Chemical research projects office fuel tank sealants review. [flight testing of fluorosilicone sealants

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.; Parker, J. A.

    1974-01-01

    The status of high-temperature fuel tank sealants for military and potentially commercial supersonic aircraft is examined. The interrelationships of NASA's sealants program comprise synthesis and development of new fluoroether elastomers, sealant prediction studies, flight simulation and actual flight testing of best state-of-the-art fluorosilicone sealants. The technical accomplishments of these projects are reviewed.

  14. Sealant Microleakage After Using Nano-Filled Bonding Agents on Saliva-Contaminated Enamel

    PubMed Central

    Paryab, Mehrsa

    2013-01-01

    Objective: The efficacy of correctly applied fissure sealants has been revealed in the prevention of caries. Saliva and moisture contamination of the etched enamel surface before sealant placement can decrease the bonding strength of the sealant to the enamel. The aim of this study was to test the new bonding agents containing nano-fillers in order to reduce the negative effect of saliva contamination on the sealant micro leakage. Materials and Methods: Seventy five sound human premolars were randomly assigned to five equal groups as follows: Group A: etching, sealant; Group B: etching, saliva contamination, sealant; Group C: etching, saliva contamination, Single bond, sealant; Group D: etching, saliva contamination, Adper Single bond 2, sealant; Group E: etching, saliva contamination, N Bond, sealant. The samples were thermo-cycled and immersed in basic fuchsine 0.5% by weight. Then, the teeth were sectioned bucco-lingually and parallel to the long axis into two segments. Finally, the length of dye penetration at the sealant-tooth interface was scored according to a four-point scale. Results: Micro-leakage was higher in group B compared to the other groups, while there were no differences among the evaluated dentin adhesives. Conclusion: The use of nano-filled bonding agents as an intermediate layer between the etched enamel and the sealant can reduce sealant micro-leakage after saliva contamination at the level of the uncontaminated enamel. PMID:25512749

  15. Laser fluorescence of dentin caries covered with a novel nano-filled sealant.

    PubMed

    Braun, Andreas; Beisel, Christian; Brede, Olivier; Krause, Felix

    2013-01-01

    The aim of the present study was to assess the possibility to measure caries-induced laser fluorescence underneath a novel nano-filled fissure sealant. Sixty freshly extracted human teeth with occlusal dentine carious lesions were horizontally divided, exposing the respective lesion. Teeth were randomly assigned to three groups: (I) white fissure sealant with filler particles (Fissurit F, Voco), (II) clear fissure sealant without filler particles (Fissurit, Voco) and (III) novel experimental fissure sealant with nano-filler particles (Voco). Starting with a sealant thickness of 3 mm, laser fluorescence measurements (DIAGNOdent, KaVo) were performed after finishing the sealant surfaces with polishing papers, reducing the material at intervals of 0.5 mm until the sealant was removed completely. Evaluating a thickness of 0.5 mm, both the clear (83 % of the baseline fluorescence after fine grit polishing) and the white sealant (25 %) did not allow to measure baseline fluorescence (p < 0.05) with no fluorescence reduction in the experimental sealant group (p > 0.05). With increasing sealer thickness, fluorescence was influenced even by the experimental material (89 % of the baseline value at 1 mm). However, by using the experimental material, statistically significant higher fluorescence values than those for the other materials under study (p < 0.05) were obtained. Thicker sealant layers and coarse grit polishing caused a decrease of laser fluorescence in all groups (p < 0.05). Employing the experimental nano-filled sealant, laser fluorescence measurements for caries detection can be performed through thicker sealant layers compared to conventional sealant materials. Thus, it might be possible to use this material to assess a caries progression underneath the sealant and administer an appropriate therapy in due time.

  16. Effect of a surface sealant on the color stability of composite resins after immersion in staining solution.

    PubMed

    Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão

    2016-01-01

    This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.

  17. Glass ionomer ART sealant and fluoride-releasing resin sealant in fissure caries prevention – results from a randomized clinical trial

    PubMed Central

    2014-01-01

    Background The relative performance of ART sealant and fluoride-releasing resin sealant in preventing fissure caries in permanent molars was compared in a randomized clinical trial conducted in southern China (ClinicalTrials.gov NCT01829334). Methods After obtaining ethical approval, healthy schoolchildren who had permanent first molars with occlusal fissures which were sound but deep or presented with only incipient caries were recruited for the study. Included molars were randomly allocated into one of four parallel study groups in units of left/right teeth per mouth. Two of the four groups adopted the methods of ART or fluoride-releasing resin sealant placement while the other two groups adopted the topical fluoride application methods. Fissure status of the molars in each group was evaluated every 6 months. Development of dentine caries and sealant retention over 24 months in the molars in the two sealant-using groups was compared in this report. Outcome on cost-effectiveness of all four groups over 36 months will be reported elsewhere. Results At baseline, a total of 280 children (383 molars) with mean age 7.8 years were involved for the two sealant groups. After 24 months, 261 children (357 molars) were followed. Proportions of molars with dentine caries were 7.3% and 3.9% in the ART sealant and fluoride-releasing resin sealant groups, respectively (chi-square test, p = 0.171). Life-table survival analysis showed that sealant retention (full and partial) rate over 24 months for the resin sealant (73%) was significantly higher than that (50%) for the ART sealant (p < 0.001). Molar survival (no development of dentine caries) rates in the ART sealant (93%) and fluoride-releasing resin sealant (96%) groups were not significantly different (p = 0.169). Multilevel logistic regression (GEE modeling) accounting for the effects of data clustering and confounding factors confirmed this finding. Conclusions Though the retention of fluoride-releasing resin sealant was better than that of the ART sealant, their effectiveness in preventing fissure caries in permanent molars did not differ significantly over 24 months. ART sealants could be a good alternative when and where resources for resin sealant placement are not readily available. PMID:24886444

  18. 21 CFR 310.515 - Patient package inserts for estrogens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for estrogens. 310.515 Section 310.515 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE NEW DRUGS Requirements for Specific New Drugs or Devices § 310.515 Patient...

  19. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Patient package inserts for oral contraceptives. 310.501 Section 310.501 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the requirements of this section is misbranded under section 502 of the Federal Food, Drug, and...

  20. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Patient package inserts for oral contraceptives. 310.501 Section 310.501 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the requirements of this section is misbranded under section 502 of the Federal Food, Drug, and...

  1. New Joint Sealants. Criteria, Design and Materials.

    ERIC Educational Resources Information Center

    Building Research Inst., Inc., Washington, DC.

    Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…

  2. Bond strength of Bis-GMA and glass ionomer pit and fissure sealants using cyclic fatigue.

    PubMed

    Dewji, H R; Drummond, J L; Fadavi, S; Punwani, I

    1998-02-01

    The aim of the study was to determine the bond strength of glass ionomer and resin-modified glass ionomer sealants compared to Bis-GMA sealants using both static and cyclic fatigue shear testing. Four materials were evaluated: D, a Bis-GMA sealant with 10% phosphoric acid etchant; FC, a resin-modified glass ionomer sealant with 20% polyacrylic acid etchant; FD, a resin-modified glass ionomer sealant with 10% polyacrylic acid etchant; and FSC, a self-cured glass ionomer sealant with no etchant. Gelatin capsules filled with the sealant material were bonded to the enamel surfaces of bovine teeth after appropriate surface conditioning and then tested in shear static and cyclic fatigue. Static and cyclic shear bond strengths, respectively, for each group were (MPa): FC: 21.1+/-2.8 and 17.1+/-3.1; FD: 14.6+/-5.9 and 8.5+/-3.1; D: 10.8+/-4.9 and 4.7+/-2.6; FSC: 8.7 (1.0 and 2.9+/-0.6. The resin-modified glass ionomer sealants had better fatigue bond strength than both Bis-GMA and self-cured glass ionomer sealants with the surface conditioning affecting the bond strength of the resin-modified glass ionomer sealants.

  3. Reimbursement rates and policies for primary molar pit-and-fissure sealants across state Medicaid programs.

    PubMed

    Chi, Donald L; Singh, Jennifer

    2013-11-01

    Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.

  4. Ability Of Optical Coherence Tomography To Detect Caries Beneath Commonly Used Dental Sealants

    PubMed Central

    Osann, Kathryn; Pharar, Jessica; Lee, Kenneth; Ahn, Yeh-chan; Tucker, Travis; Sabet, Sharareh; Chen, Zhongping; Gukasyan, Ripsik; Wilder-Smith, Petra

    2010-01-01

    Background and Objective The onset and progression of early tooth decay is often preventable with dental sealants. However, occasionally decay progresses underneath the sealant. Current technology does not permit monitoring of potential lesion progression or arrest. Dental sealants themselves mask the visual cues that identify early tooth decay, and radiographs are not sufficiently sensitive. Therefore clinicians can be reluctant to use dental sealant. The objective of this ex vivo study was to evaluate the ability of dentists to detect decay beneath commonly used dental sealants using Optical Coherence Tomography (OCT) imaging. Study Designs/Materials/Methods Forty extracted teeth were divided into equal groups of carious and non-carious teeth, as determined by visual inspection. After radiographs and OCT imaging, teeth were randomly assigned for sealant placement with one of four commonly purchased dental sealants: Clinpro™, Fuji Triage™, Embrace Wet Bond™, and Delton™. Following sealant placement, teeth were radiographed, imaged with OCT, sectioned, examined histologically, and scored as healthy/not healthy. OCT and radiographic images were scored separately. The gold standard was histopathological diagnosis from the serial sections. Cohen’s Kappa, sensitivity, negative predictive value and positive predictive value were computed for all measures. Results After 90 mins training, pre-standardized dentists were able to detect tooth decay more accurately using OCT than with visual or radiographic examination. Detection using OCT was somewhat better prior to sealant placement than afterwards. This effect varied in size depending on the type of sealant used. Radiographic diagnosis was also less accurate after sealant placement. Of the four dental sealants, Delton provided excellent positive predictive value and the best post-sealant negative predictive values. Conclusion In this ex vivo study, dentists were able to detect tooth decay beneath four commonly used dental sealants based on OCT images. Clinical investigations are now underway to determine the usefulness of this approach in vivo. PMID:20848554

  5. Microleakage of self-etching sealant on noncontaminated and saliva-contaminated enamel.

    PubMed

    2011-01-01

    The purpose of this study was to compare the microleakage of a self-etching sealant with a traditional phosphoric acid-etched sealant under noncontaminated and saliva-contaminated conditions. Fifty-two sound extracted human molars were randomly divided into 4 groups (N=13). Teeth in Groups 1 and 2 were cleaned with pumice, etched with phosphoric acid, rinsed, coated with a drying agent, placed with sealants (UltraSeal XT Plus), and light cured. Teeth in Groups 3 and 4 were cleaned with a proprietary flour pumice and rinsed prior to being sealed with a self-etching sealant (Enamel Loc). Teeth in Groups 2 and 4 were contaminated with saliva and thoroughly air-dried prior to the sealant placement. All teeth were subjected to a thermocycling process, stained with silver nitrate, and sectioned, and images of the sealant on the occlusal surface were recorded. Microleakage distance was measured in millimeters and subjected to a 2-way analysis of variance. Significantly larger microleakage distances were found for the self-etching sealant vs the traditional sealant (P<.001). Saliva contamination did not significantly affect the microleakage distance (P<.17). Under the conditions used in this in vitro study, the self-etching sealant, regardless of contamination condition, had extensive microleakage distances vs. little microleakage in the traditional phosphoric acid-etched sealant.

  6. Dental Sealants Prevent Cavities

    MedlinePlus

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  7. Evaluating Documents: The Case of Patient Package Inserts. Technical Report No. 2.

    ERIC Educational Resources Information Center

    Krug, Robert E.

    To illustrate the types of factors that must be considered in evaluating public documents, this paper analyzes a number of possible outcomes resulting from one type of document, the patient package insert (PPI) designed to provide consumers of prescription drugs with information about the drugs. It first outlines the intended sequence for a PPI:…

  8. A cost-effective analysis of fibrin sealants versus no sealant following open right hemihepatectomy for colorectal liver metastases.

    PubMed

    Pandanaboyana, Sanjay; Bell, Richard; Shah, Nehal; Lodge, J Peter A; Hidalgo, Ernest; Toogood, Giles J; Prasad, K Raj

    2017-06-01

    There is paucity of data regarding the cost-effectiveness of fibrin sealants during liver surgery. This study aimed to assess the cost-effectiveness of fibrin sealants following right hemihepatectomy for colorectal liver metastases. A prospectively maintained database between 2004 and 2013 was reviewed to identify patients who underwent a right hemihepatectomy with and without fibrin sealant application. Perioperative and post-operative outcomes were analysed to assess its cost-effectiveness. One hundred and sixty-three right hemihepatectomies were performed, of which 79 were in the fibrin sealant treatment group and 84 were in the no sealant group. No difference was seen between fibrin sealant and no sealant with regard to bile leak (P = 0.366), intra-abdominal collections (P = 0.200) and overall post-operative complications (P = 0.480). Operating costs were significantly cheaper in the no sealant group (P = 0.010). There was no difference seen in median post-operative stay between fibrin sealant versus no treatment (8 versus 9 days, P = 0.327), median total bed cost (£3900 versus £4300, P = 0.400), mean transfusion cost per patient (P = 0.201) and overall cost (£6706.15 versus £6555.80, P = 0.792). Fibrin sealant application to cut surface during liver surgery confers no cost benefit and their routine use may not be recommended. © 2014 Royal Australasian College of Surgeons.

  9. Pit and fissure sealants for preventing dental decay in permanent teeth.

    PubMed

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya; Nordblad, Anne; Mäkelä, Marjukka; Worthington, Helen V

    2017-07-31

    Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries in children and adolescents compared to no sealants. Effectiveness may, however, be related to caries incidence level of the population. This is an update of a review published in 2004, 2008 and 2013. To compare the effects of different types of fissure sealants in preventing caries in occlusal surfaces of permanent teeth in children and adolescents. Cochrane Oral Health's Information Specialist searched: Cochrane Oral Health's Trials Register (to 3 August 2016), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2016, Issue 7), MEDLINE Ovid (1946 to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Randomised controlled trials (RCTs) comparing sealants with no sealant or a different type of sealant material for preventing caries of occlusal surfaces of premolar or molar teeth in children and adolescents aged up to 20 years. Studies required at least 12 months follow-up. We excluded studies that compared compomers to resins/composites. Two review authors independently screened search results, extracted data and assessed risk of bias of included studies. We presented outcomes for caries or no caries on occlusal surfaces of permanent molar teeth as odds ratio (OR) or risk ratio (RR). We used mean difference (MD) for mean caries increment. All measures were presented with 95% confidence intervals (CI). We conducted meta-analyses using a random-effects model for comparisons where there were more than three trials; otherwise we used the fixed-effect model. We used GRADE methods to assess evidence quality. We included 38 trials that involved a total of 7924 children; seven trials were new for this update (1693 participants). Fifteen trials evaluated the effects of resin-based sealant versus no sealant (3620 participants in 14 studies plus 575 tooth pairs in one study); three trials with evaluated glass ionomer sealant versus no sealant (905 participants); and 24 trials evaluated one type of sealant versus another (4146 participants). Children were aged from 5 to 16 years. Trials rarely reported background exposure to fluoride of trial participants or baseline caries prevalence. Resin-based sealant versus no sealant: second-, third- and fourth-generation resin-based sealants prevented caries in first permanent molars in children aged 5 to 10 years (at 24 months follow-up: OR 0.12, 95% CI 0.08 to 0.19, 7 trials (5 published in the 1970s; 2 in the 2010s), 1548 children randomised, 1322 children evaluated; moderate-quality evidence). If we were to assume that 16% of the control tooth surfaces were decayed during 24 months of follow-up (160 carious teeth per 1000), then applying a resin-based sealant would reduce the proportion of carious surfaces to 5.2% (95% CI 3.13% to 7.37%). Similarly, assuming that 40% of control tooth surfaces were decayed (400 carious teeth per 1000), then applying a resin-based sealant would reduce the proportion of carious surfaces to 6.25% (95% CI 3.84% to 9.63%). If 70% of control tooth surfaces were decayed, there would be 19% decayed surfaces in the sealant group (95% CI 12.3% to 27.2%). This caries-preventive effect was maintained at longer follow-up but evidence quality and quantity was reduced (e.g. at 48 to 54 months of follow-up: OR 0.21, 95% CI 0.16 to 0.28, 4 trials, 482 children evaluated; RR 0.24, 95% CI 0.12 to 0.45, 203 children evaluated). Although studies were generally well conducted, we assessed blinding of outcome assessment for caries at high risk of bias for all trials (blinding of outcome assessment is not possible in sealant studies because outcome assessors can see and identify sealant). Glass ionomer sealant versus no sealant: was evaluated by three studies. Results at 24 months were inconclusive (very low-quality evidence). One sealant versus another sealant: the relative effectiveness of different types of sealants is unknown (very low-quality evidence). We included 24 trials that directly compared two different sealant materials. Comparisons varied in terms of types of sealant assessed, outcome measures chosen and duration of follow-up. Adverse events: only four trials assessed adverse events. No adverse events were reported. Resin-based sealants applied on occlusal surfaces of permanent molars are effective for preventing caries in children and adolescents. Our review found moderate-quality evidence that resin-based sealants reduced caries by between 11% and 51% compared to no sealant, when measured at 24 months. Similar benefit was seen at timepoints up to 48 months; after longer follow-up, the quantity and quality of evidence was reduced. There was insufficient evidence to judge the effectiveness of glass ionomer sealant or the relative effectiveness of different types of sealants. Information on adverse effects was limited but none occurred where this was reported. Further research with long follow-up is needed.

  10. Pit and fissure sealants in dental public health – application criteria and general policy in Finland

    PubMed Central

    Kervanto-Seppälä, Sari; Pietilä, Ilpo; Meurman, Jukka H; Kerosuo, Eero

    2009-01-01

    Background Pit and fissure sealants (sealants) are widely used as a non-operative preventive method in public dental health in Finland. Most children under 19 years of age attend the community-organized dental health services free of charge. The aims of this study were to find out to what extent sealants were applied, what the attitudes of dental professionals towards sealant application were, and whether any existing sealant policies could be detected among the health centres or among the respondents in general. The study evaluated changes that had taken place in the policies used during a ten year period (1991–2001). Methods A questionnaire was mailed to each chief dental officer (CDO) of the 265 public dental health centres in Finland, and to a group of general dentists (GDP) applying sealants in these health centres, giving a total of 434 questionnaires with 22 questions. The response rate was 80% (N = 342). Results A majority of the respondents reported to application of sealants on a systematic basis for children with increased caries risk. The criteria for applying sealants and the actual strategies seemed to vary locally between the dentists within the health centres and between the health centres nationwide. The majority of respondents believed sealants had short- and long-term effects. The overall use of sealants decreased towards the end of the ten year period. The health centres (N = 28) choosing criteria to seal over detected or suspected enamel caries lesion had a DMFT value of 1.0 (SD ± 0.49) at age 12 (year 2000) compared to a value of 1.2 (SD ± 0.47) for those health centres (N = 177) applying sealants by alternative criteria (t-test, p < 0.05). Conclusion There seems to be a need for defined guidelines for sealant application criteria and policy both locally and nationwide. Occlusal caries management may be improved by shifting the sealant policy from the traditional approach of prevention to interception, i.e. applying the sealants over detected or suspected enamel caries lesions instead of sealing sound teeth. PMID:19193239

  11. Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.

    PubMed

    Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena

    2016-10-21

    Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at p<0.05. From 1999-2004 to 2011-2014, among low- and higher-income children, sealant use prevalence increased by 16.2 and 8.8 percentage points to 38.7% and 47.8%, respectively. Among low-income children aged 7-11 years, the mean DFFM was almost three times higher among children without sealants (0.82) than among children with sealants. Approximately 6.5 million low-income children could potentially benefit from the delivery of sealants through SBSP. The prevalence of dental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.

  12. Effect of type and content of tackifier on adhesion of natural rubber and reclaimed natural rubber based sealant

    NASA Astrophysics Data System (ADS)

    Raethong, P.; Boonkerd, K.

    2017-07-01

    Adhesion property of natural rubber (NR) and reclaimed natural rubber (RNR) based sealant with concrete was studied here. The effect of tackifier type and loading on the tensile properties of the rubber based sealant sandwished between two flat cements was evaluated. There are three different tackifiers including Coumarone-indene resin (CI), petro resin (PE) and gum rosin (GR). The result initially showed that at the 20 phr of tackifier both NR and RNR sealant mixed with CI consumed the highest force to separate the rubber based sealant from the concrete. This might be due to the highest compatiblility between CI and rubber. Regardless of the tackifier type, all NR based sealants showed the cohesive failure while all RNR based sealants only showed the adhesive failure. Moreover, the NR based sealant seemed to be stronger than the RNR based one. When considering the effect of CI loading on the adhesion, it was shown that for both NR and RNR based sealents, the highest stress was observed when the rubber based sealant loaded with the 20 phr of CI.

  13. Developing a test method to investigate water susceptibility of joint and crack sealants.

    DOT National Transportation Integrated Search

    2016-10-31

    Sealants are commonly used to insulate cracks and joints preventing water from entering the underlying structure. However, extended exposure of sealants to water has shown to negatively impact sealants properties causing gradual degradation of sealan...

  14. Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive—a Laboratory and Clinical Perspective

    PubMed Central

    Spotnitz, William D.

    2014-01-01

    Background. Fibrin sealant became the first modern era material approved as a hemostat in the United States in 1998. It is the only agent presently approved as a hemostat, sealant, and adhesive by the Food and Drug Administration (FDA). The product is now supplied as patches in addition to the original liquid formulations. Both laboratory and clinical uses of fibrin sealant continue to grow. The new literature on this material also continues to proliferate rapidly (approximately 200 papers/year). Methods. An overview of current fibrin sealant products and their approved uses and a comprehensive PubMed based review of the recent literature (February 2012, through March 2013) on the laboratory and clinical use of fibrin sealant are provided. Product information is organized into sections based on a classification system for commercially available materials. Publications are presented in sections based on both laboratory research and clinical topics are listed in order of decreasing frequency. Results. Fibrin sealant remains useful hemostat, sealant, and adhesive. New formulations and applications continue to be developed. Conclusions. This agent remains clinically important with the recent introduction of new commercially available products. Fibrin sealant has multiple new uses that should result in further improvements in patient care. PMID:24729902

  15. Systematic review on the use of matrix-bound sealants in pancreatic resection.

    PubMed

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-11-01

    Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.

  16. 48 CFR 552.211-75 - Preservation, Packaging and Packing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Preservation, Packaging....211-75 Preservation, Packaging and Packing. As prescribed in 511.204(b)(2), insert the following clause: Preservation, Packaging, and Packing (FEB 1996) Unless otherwise specified, all items shall be...

  17. 48 CFR 852.214-73 - Alternate packaging and packing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Alternate packaging and....214-73 Alternate packaging and packing. As prescribed in 814.201-6(b)(3), insert the following provision: Alternate Packaging and Packing (JAN 2008) The bidder's offer must clearly indicate the quantity...

  18. A comparison of the effects of toothbrushing and handpiece prophylaxis on retention of sealants.

    PubMed

    Kolavic Gray, Shellie; Griffin, Susan O; Malvitz, Dolores M; Gooch, Barbara F

    2009-01-01

    Tooth surface cleaning before acid etching is considered to be an important step in the retention of resin-based pit-and-fissure sealants. The authors reviewed and summarized instructions for cleaning tooth surfaces from five manufacturers of 10 unfilled resin-based sealants marketed in the United States. The authors also searched electronic databases for studies that directly compared the effects of different surface-cleaning methods on sealant retention and for systematic reviews of the effectiveness of sealants. They explored the association between surface-cleaning methods and sealant retention in the studies included in the systematic reviews. They calculated the summary weighted retention rates for studies that used either a handpiece or toothbrush prophylaxis. All of the sealant manufacturers' instructions for use (IFU) recommended cleaning the tooth before acid etching. None of the IFU directly stated that a handpiece was required to perform the cleaning, but five IFU implied the use of handpiece prophylaxis. None of the IFU recommended surface-altering procedures in caries-free teeth. Direct evidence from two clinical trials showed no difference in complete sealant retention between surfaces cleaned mechanically with pumice or prophylaxis paste and those cleaned with air-water syringe or dry toothbrushing. Indirect evidence from 10 studies found that weighted summary retention by year after sealant placement in studies that used toothbrush prophylaxis was greater than or equivalent to values for studies that used handpiece prophylaxis. Levels of sealant retention after surface cleaning with toothbrush prophylaxis were at least as high as those associated with hand-piece prophylaxis. This finding may translate into lower resource costs for sealant placement.

  19. Systematic review on the use of matrix-bound sealants in pancreatic resection

    PubMed Central

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-01-01

    Background Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. Methods A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Results Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). Conclusions The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. PMID:26292846

  20. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    PubMed

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  1. Caries-preventive effect of fissure sealant containing surface reaction-type pre-reacted glass ionomer filler and bonded by self-etching primer.

    PubMed

    Shimazu, Kisaki; Ogata, Kiyokazu; Karibe, Hiroyuki

    2012-01-01

    We aimed to evaluate the caries-preventive effect of a fissure sealant containing surface reaction-type pre-reacted glass ionomer (S-PRG) filler and bonded by self-etching primer versus those of 2 conventional resin-based sealants bonded by acid etching in terms of its impact on enamel demineralization and remineralization, enamel bond strength, and integrity of debonded enamel surfaces. Demineralization, remineralization, and bond strength on untreated enamel and enamel subsurface lesions of bovine incisors were assessed among the sealants by polarizing microscopy and microradiography; debonded enamel surfaces were examined by scanning electron microscopy. The conventional resin-based sealants bonded by acid etching caused surface defects on the enamel subsurface lesions and significantly increased the lesion depth (p = 0.014), indicative of enamel demineralization. However the S-PRG filler-containing sealant bonded by self-etching primer maintained the enamel surface integrity and inhibited enamel demineralization. No difference in bond strength on both untreated enamel and enamel subsurface lesions was noted among the sealants. An S-PRG filler-containing fissure sealant bonded by self-etching primer can prevent enamel demineralization, microleakage, and gaps without the tags created by acid etching regardless of the enamel condition. Such sealants are suitable for protecting the pits and fissures of immature permanent teeth.

  2. Microleakage and penetration of a hydrophilic sealant and a conventional resin-based sealant as a function of preparation techniques: a laboratory study.

    PubMed

    Khogli, Ahmed Eltigani; Cauwels, Rita; Vercruysse, Chris; Verbeeck, Ronald; Martens, Luc

    2013-01-01

    Optimal pit and fissure sealing is determined by surface preparation techniques and choice of materials. This study aimed (i) to compare the microleakage and penetration depth of a hydrophilic sealant and a conventional resin-based sealant using one of the following preparation techniques: acid etching (AE) only, a diamond bur + AE, and Er:YAG laser combined with AE, and (ii) to evaluate the microleakage and penetration depth of the hydrophilic pit and fissure sealant on different surface conditions. Eighty recently extracted 3rd molars were randomly assigned to eight groups of ten teeth according to the material, preparation technique, and surface condition. For saliva contamination, 0.1 mL of fresh whole human saliva was used. All samples were submitted to 1000 thermal cycles and immersed in 2% methylene blue dye for 4 h. Sections were examined by a light microscope and analysed using image analysis software (Sigmascan(®)). The combination of Er:YAG + AE + conventional sealant showed the least microleakage. The sealing ability of the hydrophilic sealant was influenced by the surface condition. Er:YAG ablation significantly decreased the microleakage at the tooth-sealant interface compared to the non-invasive technique. The hydrophilic sealant applied on different surface conditions showed comparable result to the conventional resin-based sealant. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  3. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    PubMed Central

    Cha, Han Gyu; Shin, Ho Seong; Kang, Moon Seok; Nam, Seung Min

    2012-01-01

    Background The most common complication of latissimus dorsi myocutaneous flap in breast reconstruction is seroma formation in the back. Many clinical studies have shown that fibrin sealant reduces seroma formation. We investigated any statistically significant differences in postoperative drainage and seroma formation when utilizing the fibrin sealant on the site of the latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction after skin-sparing partial mastectomy. Methods A total of 46 patients underwent immediate breast reconstruction utilizing a latissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedure without fibrin sealant and the other 23 were administered the fibrin sealant. All flaps were elevated with manual dissection by the same surgeon and were analyzed to evaluate the potential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U test were used for analyzing the drainage volume according to age, weight of the breast specimen, and body mass index. Results Although not statistically significant, the cumulative drainage fluid volume was higher in the control group until postoperative day 2 (530.1 mL compared to 502.3 mL), but the fibrin sealant group showed more drainage beginning on postoperative day 3. The donor site comparisons showed the fibrin sealant group had more drainage beginning on postoperative day 3 and the drain was removed 1 day earlier in the control group. Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Because the benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussed with patients before its use as a part of informed consent. PMID:23094246

  4. Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.

    PubMed

    Kim, Jeong Tae; Kim, Youn Hwan; Kim, Sang Wha

    2017-07-01

    Fibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant. Between 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles. Among the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65). Fibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017. © 2016 Wiley Periodicals, Inc.

  5. Adherence and efficacy of an external teat sealant to prevent new intramammary infections in the dry period.

    PubMed

    Lim, G H; Leslie, K E; Kelton, D F; Duffield, T F; Timms, L L; Dingwell, R T

    2007-03-01

    The efficacy and adherence of an external teat sealant applied at drying off was evaluated in 2 studies between 1997 and 1999. At drying off, 2 quarters were randomized to receive intramammary dry-cow antibiotic therapy, and the remaining 2 quarters were treated with either a single or double application of external teat sealant. Approximately 3 d before calving, all teats that had been dipped at drying off were redipped in a single coating of teat sealant. Adherence of the teat sealant was scored for the first 2 wk after drying off, and physical traits of the teat skin and teat ends were recorded. Quarter milk samples were collected 1 wk before drying off, at drying off, 0 to 7 d, and 14 to 21 d postcalving. Somatic cell counts were determined from quarter samples taken at d 7 and 14 to 21 d after calving. Data were analyzed from 172 dry periods of 162 cows. The mean time of sealant adherence following drying off application was 3 +/- 0.13 d. Double sealant application significantly increased the duration of adherence by 0.67 d. Teats that had teat sealant applied twice at drying off and that had up to 3 d of adherence had the lowest linear score (LS) at 14 to 21 d (1.89 +/- 0.31) of all quarters. The LS of quarters that received antibiotic therapy only was 2.27 +/- 0.19. The majority of intramammary infections identified at drying off were caused by the minor pathogens, coagulase-negative staphylococci and Corynebacterium bovis (51 and 23%, respectively). The results from this study indicate that duration of sealant adherence to the teat-end should be considered when evaluating the impact of teat sealant treatment at drying off on the level of infection after calving. Double sealant application, cooler seasons, and longer teat lengths were associated with a significant increase in the duration of sealant adherence to the teat-end.

  6. A One-Year Evaluation of a Free Fissure Sealant Program

    PubMed Central

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-01-01

    Statement of Problem: Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran’s oral health reform plan is not clear. Objectives: To evaluate the longevity of different fissure sealant applied in Iran’s oral health reform plan in Fars Province (south of Iran) after one year. Materials and Methods: Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Results: Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant (p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child’s gender, age, and being caries-free. Conclusions: Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application. PMID:28959758

  7. A One-Year Evaluation of a Free Fissure Sealant Program.

    PubMed

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-12-01

    Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran's oral health reform plan is not clear. To evaluate the longevity of different fissure sealant applied in Iran's oral health reform plan in Fars Province (south of Iran) after one year. Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant ( p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child's gender, age, and being caries-free. Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application.

  8. Watermarking spot colors in packaging

    NASA Astrophysics Data System (ADS)

    Reed, Alastair; Filler, TomáÅ.¡; Falkenstern, Kristyn; Bai, Yang

    2015-03-01

    In January 2014, Digimarc announced Digimarc® Barcode for the packaging industry to improve the check-out efficiency and customer experience for retailers. Digimarc Barcode is a machine readable code that carries the same information as a traditional Universal Product Code (UPC) and is introduced by adding a robust digital watermark to the package design. It is imperceptible to the human eye but can be read by a modern barcode scanner at the Point of Sale (POS) station. Compared to a traditional linear barcode, Digimarc Barcode covers the whole package with minimal impact on the graphic design. This significantly improves the Items per Minute (IPM) metric, which retailers use to track the checkout efficiency since it closely relates to their profitability. Increasing IPM by a few percent could lead to potential savings of millions of dollars for retailers, giving them a strong incentive to add the Digimarc Barcode to their packages. Testing performed by Digimarc showed increases in IPM of at least 33% using the Digimarc Barcode, compared to using a traditional barcode. A method of watermarking print ready image data used in the commercial packaging industry is described. A significant proportion of packages are printed using spot colors, therefore spot colors needs to be supported by an embedder for Digimarc Barcode. Digimarc Barcode supports the PANTONE spot color system, which is commonly used in the packaging industry. The Digimarc Barcode embedder allows a user to insert the UPC code in an image while minimizing perceptibility to the Human Visual System (HVS). The Digimarc Barcode is inserted in the printing ink domain, using an Adobe Photoshop plug-in as the last step before printing. Since Photoshop is an industry standard widely used by pre-press shops in the packaging industry, a Digimarc Barcode can be easily inserted and proofed.

  9. The retention of pit and fissure sealants placed in primary school children by Dental Health Services, Victoria.

    PubMed

    Messer, L B; Calache, H; Morgan, M V

    1997-08-01

    The benefit of a public sector sealant programme for children in Australia is yet to be established. This study evaluated sealants placed by therapists of the School Dental Service in Victoria, between 1989 and 1994, on permanent teeth of children in 15 primary schools in Melbourne. Seven hundred and seventy four children aged 6-12 years were examined in school dental clinics by six calibrated examiners. A total of 5363 sealants placed on 2875 permanent teeth (including 2616 first molars, 91 per cent of sample) up to four and a half years previously was examined. Values for complete and partial sealant retention were highest for premolars (86 per cent, 9 per cent respectively, total 95 per cent); similar for occlusal surfaces of maxillary and mandibular first molars (63 per cent, 30 per cent; 62 per cent, 32 per cent respectively) and buccal pits of mandibular molars (66 per cent); and low for pits/fissures of Carabelli's cusps of maxillary molars (44 per cent). Cross-sectional examination up to 24 months for both maxillary and mandibular first molars indicated average values of 67 per cent complete retention, 27 per cent partial retention, 6 per cent missing; thereafter complete retention decreased and partial retention increased. Sealant failures in the six months post-placement were attributed to technique failure. Regardless of sealant retention, caries experience was low under partially retained or missing sealants (4.5 per cent) and completely retained sealants (0.4 per cent). It is concluded that the SDS sealant programme is a sound preventive dental public health approach.

  10. Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  11. Evidence-practice gap for dental sealant application: results from a dental practice-based research network in Japan.

    PubMed

    Yokoyama, Yoko; Kakudate, Naoki; Sumida, Futoshi; Matsumoto, Yuki; Gilbert, Gregg H; Gordan, Valeria V

    2016-12-01

    The study aims were: (i) to examine dentist practice patterns regarding treatment recommendations for dental sealants; and (ii) to identify characteristics associated with this recommendation. The study was performed using a cross-sectional questionnaire survey (Clinicaltrials.gov registration number NCT01680848). Participants were Japanese dentists (n = 282) recruited from the Dental Practice-based Research Network Japan. Three clinical photographs of the occlusal surface of a mandibular first molar were presented, portraying increasing depths of cavitation in a 12-year-old patient with high caries risk. Sealants would be an appropriate treatment in all three scenarios. We asked about the treatment decision for each case. We then performed multiple logistic regression analyses to evaluate associations between the decision to recommend sealants, and dentist, patient and practice characteristics. Responses were obtained from 189 dentists (response rate = 67%). In the hypothetical scenarios, dentists' recommendations for sealants for the 12-year-old patient varied from 16% to 26% across the three hypothetical clinical scenarios. Multiple logistic regression analysis indicated that dentist agreement with the efficacy of assessment for caries risk showed a significant association with the percentages of patients receiving sealants. Dentist practice patterns for sealant treatment recommendation show changes that are dependent on caries severity. The dentists' recommendations for sealants for the 12-year-old patient were low for all three selected scenarios, based on indications for sealants in the American Dental Association guidelines. Recommending a sealant showed a significant relationship with the dentist having a higher agreement with efficacy of caries risk assessment. © 2016 FDI World Dental Federation.

  12. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEPT 2005) (a) The Contractor shall...

  13. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  14. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  15. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEP 2005) (a) The Contractor shall...

  16. 21 CFR 516.165 - Records and reports.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within 60 days thereafter. The report must contain data and information for the full reporting period..., include a summary of those changes and the holder's and distributor's current package labeling, including any package inserts. For large-size package labeling or large shipping cartons, submit a...

  17. 21 CFR 516.165 - Records and reports.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within 60 days thereafter. The report must contain data and information for the full reporting period..., include a summary of those changes and the holder's and distributor's current package labeling, including any package inserts. For large-size package labeling or large shipping cartons, submit a...

  18. An investigation into sealant restoration usage in general dental practice in England.

    PubMed

    Hassall, D C; Mellor, A C

    2001-10-13

    A study was undertaken to investigate attitudes to sealant restorations and their usage in general dental practice in England. Seventy three dentists in three areas (Doncaster, Hereford/Worcester and Wycombe) provided retrospective details of treatment provided over a one year period for 4,250 6-12 and 13-15 year old subjects. Fifty nine of these dentists then completed a telephone questionnaire relating to their treatment patterns and attitudes to sealant restorations. The treatment data indicated that only 59 of the 4,250 children received a sealant restoration during the study period. Of the 44 dentists who claimed in the questionnaire to be using sealant restorations, only 28 had placed them in their selected patients. Positive attitudes to sealant restorations were expressed but also concerns that may be prejudicing usage.

  19. Analysis of the hemostatic potential of modern topical sealants on arterial and venous anastomoses: an experimental porcine study.

    PubMed

    Fonouni, Hamidreza; Kashfi, Arash; Majlesara, Ali; Stahlheber, Oliver; Konstantinidis, Lukas; Kraus, Thomas W; Mehrabi, Arianeb; Oweira, Hani

    2017-09-01

    One of the widely accepted adjunctive agents in the variety of surgical modalities are sealants. Our study aim was to compare four commonly used modern sealants in a standardized experimental setting to assess their feasibility, and hemostatic efficacy in vascular anastomosis. Forty landrace pigs (weight: 24.7 ± 3.8 kg) were randomized into the control (n = 8) and four sealant groups; TachoSil® (n = 8), Tissucol Duo® (n = 8), Coseal® (n = 8), and FloSeal® (n = 8). After doing a portal vein end-to-end anastomosis as well as stitches of aortic incision, the sealants were applied on anastomotic site. The control group was left intact. In portal vein anastomosis, the sealants led to a complete hemostasis significantly better than control group. The mean of blood loss was also significantly reduced. In successful subgroups, there was a difference in the mean-time to reach complete hemostasis ranging from 15 s in Coseal® to 76 s in FloSeal® group (p  < 0.05). In aortotomy experiments, except Tissucol Due®, which had insufficient hemostasis, other sealants led to a complete hemostasis. The mean blood loss was significantly reduced in sealants groups as well. The four sealants are effective in reducing the suture-hole bleeding in portal vein anastomosis. However, the hemostatic potential is heterogeneous among sealants. This means that "one-size-fits-all" approach is not appropriate for application of sealants in diversity of vascular surgery and it should be based on the type and the severity of injury and the structure of tissue. Comparison of hemostasis efficacy of four modern sealants (TachoSil®, Tissucol Duo®, Coseal®, and FloSeal®) in vascular anastomosis in porcine model. The figures below show the total blood loss (g) in the control and sealant groups after aortotomy (left) and portal vein anastomosis (right). The mean of blood loss decreased significantly by the usage of sealants in both experiment groups as compared to control group (*: p < 0.05; sealant groups vs. control group). 1. The right column shows the mean of blood loss (g) in all experiments in each group. 2. The middle column presents the subgroup with unsuccessful hemostasis at the end of observation time (Tmax = 20 sec. for aortotmy and 300 sec. for portal vein anastomosis). 3. The left column shows mean of total blood loss in subgroups with successful hemostasis during observation time (20 sec for aortotomy and 300 sec for portal vein).

  20. Urethral Foreign Bodies: Clinical Presentation and Management.

    PubMed

    Palmer, Cristina J; Houlihan, Matthew; Psutka, Sarah P; Ellis, K Alexandria; Vidal, Patricia; Hollowell, Courtney M P

    2016-11-01

    To review a single institution's 15-year experience with urethral foreign bodies, including evaluation, clinical findings, and treatment. In total, 27 patients comprising 35 episodes of inserted urethral foreign bodies were reviewed at Cook County Hospital between 2000 and 2015. Retrospective chart review was performed to describe the clinical presentation, rationale for insertion, management, recidivism, and sequelae. Median patient age was 26 (range 12-60). Twenty-six patients (97 %) were male, 1 was female (3%). Items inserted included pieces of plastic forks, spoons, metal screws and aluminum, pieces of cardboard or paper, staples, writing utensils such as pens and pencils, as well as coaxial cable and spray foam sealant. Reported reasons for insertion were self-stimulation, erectile enhancement, and attention seeking. Presenting symptoms included dysuria, gross hematuria, urinary retention, urinary tract infection, and penile discharge. The most common technique for removal was manual extraction with extrinsic pressure (n = 19, 54%). Other methods include endoscopic retrieval (n = 8, 23%), open cystotomy (n = 1, 3%), and voiding to expel the foreign body (n = 7, 20%). Postremoval complications included urinary tract infection (n = 7), sepsis (n = 4), urethral false passage (n = 5), laceration (n = 5), and stricture (n = 1). We present the largest single-institutional series of urethral foreign bodies to date. Urethral foreign body insertion is a relatively rare occurrence and, commonly, is a recurrent behavior. Urethral trauma related to foreign body insertion is associated with significant risk of infection and urethral injury with long-term sequelae. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Monitoring Sealant Durability during Instrumented Outdoor Exposure with Variation in Prestrain

    Treesearch

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt

    2015-01-01

    Sealants are a vital part of a building’s environmental barrier envelope. Their ability to bond to numerous dissimilar substrates and form cure-in-place seals results in their widespread use throughout single story and high rise buildings. A typical 40 story concrete and glass facade building can have 70 miles of sealant bonds. Failure of sealants can lead to energy...

  2. Ion release and in vitro enamel fluoride uptake associated with pit and fissure sealants containing microencapsulated remineralizing agents.

    PubMed

    Burbank, Brant D; Cooper, Ryan L; Kava, Alyssa; Hartjes, Jennifer M; McHale, William A; Latta, Mark A; Gross, Stephen M

    2017-04-01

    To determine if pit-and-fissure sealants with microencapsulated remineralizing agents with sustained release of fluoride, calcium and phosphate ions could promote enamel fluoride uptake by demineralized tooth structure. Sealants that contained 5 w/w% microcapsules with aqueous solutions of 5M Ca(NO3)2 or 0.8M NaF or 6.0M K2HPO4 or a mixture of all three were prepared. Ion release profiles were measured as a function of time. Enamel fluoride uptake by demineralized tooth structure was determined. Sustained release of fluoride, calcium and phosphate ions from a sealant was demonstrated. Fluoride uptake by demineralized enamel was significantly increased compared to a control sealant manufactured without microcapsules (P< 0.01). Bovine enamel that contained 2.2±2.1 µg F/g of enamel prior to exposure to a sealant without microcapsules had 2.3±0.5 after 90 days. Enamel exposed to sealant with 5w/% NaF microcapsules went from 3.5±3.5 µg F/g of enamel prior to exposure to 148±76 after 90 days. Enamel exposed to sealant with 2 w/w% NaF, 2 w/w% Ca(NO3)2 and 1 w/w% K2HPO4 microcapsules went from 1.7±0.7 µg F/g of enamel prior to exposure to 190±137 after 90 days. Sealants with encapsulated remineralizing agents were capable of releasing biologically available fluoride, calcium, and phosphate ions. Incorporation of these microcapsules in pit and fissure sealants is a promising method for remineralization determined by enamel fluoride uptake measurements.

  3. Polyethylene glycol hydrogel polymer sealant for vitrectomy surgery: an in vitro study of sutureless vitrectomy incision closure.

    PubMed

    Hariprasad, Seenu M; Singh, Ajay

    2011-03-01

    To test a novel hydrogel sealant to secure sutureless sclerotomies under variable intraocular pressure conditions. In cadaver eyes, 23- and 20-gauge (G) sclerotomies were constructed. Sixteen 23-G beveled sclerotomies were constructed in 4 eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were left bare. All sclerotomies were monitored for leaks while the intraocular pressure was elevated. The pressure on incision leakage was recorded as the leak pressure (maximum tested = 140 mm Hg). Additionally, sixteen 20-G sclerotomies were constructed in 4 other eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were sutured. These incisions were similarly pressure tested. Among the 23-G incisions, hydrogel sealant application to the incisions significantly increased the leak pressure relative to bare incisions: mean (SE), 131.8 (8.2) vs 39.5 (5.2) mm Hg, respectively (P < .001). Only 1 of the 8 sealant-treated 23-G incisions leaked below 140 mm Hg, compared with all of the 8 bare incisions. Among the 20-G incisions, there was no difference in leak pressure among sealant-treated and sutured incisions: mean (SE), 140.0 (0.0) vs 136.3 (3.8) mm Hg, respectively (P = .35). None of the 8 sealant-treated 20-G incisions leaked below 140 mm Hg, compared with 1 of the 8 sutured incisions. Hydrogel sealant significantly increased the leak pressure among 23-G incisions relative to 23-G bare incisions and was equivalent to suturing among 20-G incisions. Hydrogel sealants effectively close vitrectomy incisions and may decrease the incidence of postoperative endophthalmitis and hypotony.

  4. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    PubMed

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p<0.001). Also both groups revealed a decreasing retention rate over the 4-year period (p<0.001). There was no difference in dental caries increment rate and enamel breakdowns at the end of the study (p>0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  5. Resealing concrete pavement joints

    DOT National Transportation Integrated Search

    1999-07-01

    The primary objective of this study was to evaluate the relative performance of the selected joint sealant materials. Other objectives were to determine the effect of selected sealant configurations and installation methods, and to identify sealant m...

  6. Sealant retention is better assessed through colour photographs than through the replica and the visual examination methods.

    PubMed

    Hu, Xuan; Fan, Mingwan; Rong, Wensheng; Lo, Edward C M; Bronkhorst, Ewald; Frencken, Jo E

    2014-08-01

    The aim of this study was to test the hypothesis that the colour photograph method has a higher level of validity for assessing sealant retention than the visual clinical examination and replica methods. Sealed molars were assessed by two evaluators. The scores for the three methods were compared against consensus scores derived through assessing retention from scanning electron microscopy images (reference standard). The presence/absence (survival) of retained sealants on occlusal surfaces was determined according to the traditional and modified categorizations of retention. Sensitivity, specificity, and Youden-index scores were calculated. Sealant retention assessment scores for visual clinical examinations and for colour photographs were compared with those of the reference standard on 95 surfaces, and sealant retention assessment scores for replicas were compared with those of the reference standard on 33 surfaces. The highest mean Youden-index score for the presence/absence of sealant material was observed for the colour photograph method, followed by that for the replica method; the visual clinical examination method scored lowest. The mean Youden-index score for the survival of retained sealants was highest for the colour photograph method for both the traditional (0.882) and the modified (0.768) categories of sealant retention, whilst the visual clinical examination method had the lowest Youden-index score for these categories (0.745 and 0.063, respectively). The colour photograph method had a higher validity than the replica and the visual examination methods for assessing sealant retention. © 2014 Eur J Oral Sci.

  7. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    PubMed

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  8. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Conlin, Francis; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  9. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  10. Retention of Moisture-tolerant and Conventional Resin-based Sealant in Six- to Nine-year-old Children.

    PubMed

    Khatri, Sachin G; Samuel, Srinivasan Raj; Acharya, Shashidhar; Patil, Snehal; Madan, Kavita

    2015-01-01

    The purpose of this study was to evaluate and compare the retention rates and development of caries in permanent molars in children sealed with moisture-tolerant, resin-based (Embrace WetBond), and conventional resin-based (Helioseal) sealant over a period of one year. This was a double blind, split-mouth, randomized controlled trial among six- to nine-year-olds. Sixty-eight permanent mandibular first molars in 34 children were randomly assigned to be sealed with Embrace WetBond or Helioseal sealant. The final sample was 32 children with 64 teeth. At 12 months, 23 of 32 (72 percent) sealants were completely retained in Embrace WetBond, whereas only 16 of 32 (50 percent) were retained in the Helioseal group. There was a statistically significant difference in retention rates of Embrace WetBond and Helioseal sealants at 12 months (P<.05). At 12 months follow-up, only two teeth developed caries in Embrace WetBond; in the Helioseal group, five teeth developed caries (two initial and three enamel caries). Embrace WetBond was superior to Helioseal sealant, as Embrace exhibited higher retention and lower caries scores. Embrace WetBond can be preferred over conventional resin-based sealants for community and outreach sealant programs where use of rubber dam for moisture control is difficult to practice.

  11. [Development of elastameric sealant designed for arterial field].

    PubMed

    Matsuda, Takehisa; Nakajima, Nobuyuki

    2013-04-01

    The development of a reliable surgical sealant specific for arterial tissues has been long awaited. In this article, first the "ideal" adhesion mechanism formulated from biomechanical concept is proposed for ensured hemostasis in dissected arteries with pulsatile flow. An urethane prepolymer prepared along the design criteria is viscous liquid. Due to its high water absorbility and high reactivity with water, the sealant applied to vascular tissues becomes an elastomer within several minutes. When the sealant was applied to dissected canine abdominal arteries with 3 stay sutures, followed by declamping 5 minutes, neither bleeding nor detrimental effect on tissue morphogenesis was observed. This sealant is being ready to the market.

  12. Microtensile Bond Strength of Embrace Wetbond Hydrophilic Sealant in Different Moisture Contamination: An In-Vitro Study.

    PubMed

    Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti

    2015-07-01

    Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.

  13. Self-Healable and Reprocessable Polysulfide Sealants Prepared from Liquid Polysulfide Oligomer and Epoxy Resin.

    PubMed

    Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu

    2017-05-10

    Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.

  14. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    PubMed

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  15. Fibrin Sealants in Dura Sealing: A Systematic Literature Review

    PubMed Central

    2016-01-01

    Background Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. Methods A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. Results A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. Conclusions A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety. PMID:27119993

  16. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    PubMed

    Esposito, Felice; Angileri, Filippo Flavio; Kruse, Peter; Cavallo, Luigi Maria; Solari, Domenico; Esposito, Vincenzo; Tomasello, Francesco; Cappabianca, Paolo

    2016-01-01

    Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety.

  17. The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2007-01-01

    This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments

  18. Use of occlusal sealant in a community program and caries incidence in high- and low-risk children.

    PubMed

    Baldini, Vânia; Tagliaferro, Elaine Pereira da Silva; Ambrosano, Gláucia Maria Bovi; Meneghim, Marcelo de Castro; Pereira, Antonio Carlos

    2011-08-01

    The aims of this study were to investigate the effectiveness of sealant placement under the guidelines of the Oral Health Promotion Program for Children and Adolescents (Portugal), and to test the influence of clinical and socioeconomic variables on the DMFT increment in 277 children, born in 1997. A dental hygienist performed the initial examinations and sealant placement (Helioseal, Vivadent) on the permanent first molars in 2005. These activities were registered in dental records that were assessed in 2007. Children were classified according to caries risk at baseline [high (HR: DMFT+dmft>0); low (LR: DMFT+dmft=0) risk] and sealant placement as follows: HR-S and LR-S Groups (with sealant placement); HR-NS and LR-NS Groups (without sealant placement). A calibrated dentist performed the final examination in 2007 at school, based on the World Health Organization recommendations. The variables collected were: dental caries, visible dental plaque, malocclusions, and socioeconomic level (questionnaire sent to children's parents). For univariate (Chi-square or Fisher tests) and multivariate (Multiple logistic regression) analyses the DMFT increment >0 was selected as dependent variable. Approximately 17.0% of the children showed DMFT increment>0 (mean=0.25). High-risk children presented a significant increase in the number of decayed and/or filled teeth. These children had 7.94 more chance of developing caries. Children who did not receive sealant were 1.8 more prone to have DMFT increment >0. It appears that sealant placement was effective in preventing dental caries development. Moreover, the variables "risk" and "sealant placement" were predictors for DMFT increment in the studied children.

  19. The prevalence of dental caries and fissure sealants in 12 year old children by disadvantaged status in Dublin (Ireland).

    PubMed

    Sagheri, D; McLoughlin, J; Clarkson, J J

    2009-03-01

    The aim was to record dental caries levels and the presence of fissure sealants in 12-year-old schoolchildren whose domestic water supply had been fluoridated since birth in Dublin (Ireland). Cross-sectional study. Participants A representative, random sample of 12-year-old schoolchildren in north-west Dublin. Dental caries levels were recorded using WHO criteria and fissure sealant was recorded when sealant was detectable on a permanent molar tooth. Medical card ownership, as a surrogate for disadvantage, was recorded by use of a questionnaire. Three-hundred and thirty-two (332) children were examined. The mean DMFT was 0.80 (SD 1.24). Analysis (Mann-Whitney U test) based on stratification of the sample according to medical-card status revealed no statistically significant difference between DMFT median scores of children of medical-card holders (i.e., social disadvantage background) and non medical-card holders (p-value = 0.23). However, the data revealed a social gradient in the presence of at least one fissure sealant. Approximately 10% more children in the group of medical-card holders had no fissure sealants present. Fisher's exact test was used to examine the association between the absence of fissure sealants and at least one fissure sealant between the two groups and was considered to be statistically significant (p-value = 0.04). This study demonstrated a social gradient in the presence of fissure sealants, but no such gradient in dental caries levels. This demonstrates the importance of population-based measures in the prevention of dental caries, such as water fluoridation, in reducing oral health inequalities.

  20. Product evaluation : Ruscoe 983 joint sealant

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...

  1. Development of the crack sealant adhesion test.

    DOT National Transportation Integrated Search

    2009-04-01

    Crack sealants are widely used in Texas to prevent water from entering into lower structural layers thereby : extending pavement life. However, most current crack sealants have been reported to have a very short life mainly due : to adhesive failures...

  2. PCC/AC shoulder joint seal evaluation

    DOT National Transportation Integrated Search

    1999-05-07

    This report presents the findings on the evaluation of Crafco Incorporated Roadsaver 903 SL Silicone Sealant and Dow Corning 890 SL Silicone Sealant. The Research Technical Panel had proposed to use the two self-leveling silicone joint sealants in te...

  3. Replacement Non-Toxic Sealants for Standard Chromated Sealants

    DTIC Science & Technology

    2005-02-01

    material’s mechanical or physical properties and resistance to degradation. As sealant formulations for the Class B-2 worklife were developed by PRC...results ofthis testing, Class B-1I2 and C-12 worklife materials were formulated and are being tested. In addition to the testing that UDRI conducted, two...successfully accomplished in this program. An optimized Class B-2 worklife of the sealant compound designated RW3758-71, Lot no. RT0946, completed

  4. A randomized controlled trial of cluster audit and feedback on the quality of dental sealant for rural schoolchildren.

    PubMed

    Tianviwat, S; Hintao, J; Chongsuvivatwong, V; Thitasomakul, S

    2016-03-01

    To examine whether audit and feedback could improve the quality of the application of dental sealant in rural Thai school children. A single blind, cluster randomized controlled trial was conducted. Hospital-based and school-based school sealant applied by dental nurses in Southern province of Thailand. Dental nurses and school children who received dental sealant were involved. The intervention consisted of confidential feedback of data and tailor-made problem-solving workshops. Sealant quality was measured by sealant retention and caries on sealed surfaces at six-month after sealing. The teeth examinations were done among different groups of children prior and after the intervention. After the intervention, the sealant retention rate increased dramatically in the intervention group, whereas in the control group the rate was similar to that found at baseline. The rate of caries after the intervention was stable in the intervention group and increased slightly in the control group. At the beginning of the study, the adjusted odds ratio of complete sealant retention between the intervention and control group was 0.47 which increased to 1.99 at the end of the study. However, no effect on caries on sealed surfaces was observed. The intensive focus on actual problems during the audit and feedback improved the dental nurses' performance and the quality of the dental service, although it had no statistical impact on the incidence of caries.

  5. Parametric Study of Sealant Nozzle

    NASA Astrophysics Data System (ADS)

    Yamamoto, Yoshimi

    It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.

  6. ProtSqueeze: simple and effective automated tool for setting up membrane protein simulations.

    PubMed

    Yesylevskyy, Semen O

    2007-01-01

    The major challenge in setting up membrane protein simulations is embedding the protein into the pre-equilibrated lipid bilayer. Several techniques were proposed to achieve optimal packing of the lipid molecules around the protein. However, all of them possess serious disadvantages, which limit their applicability and discourage the users of simulation packages from using them. In the present work, we analyzed existing approaches and proposed a new procedure of protein insertion into the lipid bilayer, which is implemented in the ProtSqueeze software. The advantages of ProtSqueeze are as follows: (1) the insertion algorithm is simple, understandable, and controllable; (2) the software can work with virtually any simulation package on virtually any platform; (3) no modification of the source code of the simulation package is needed; (4) the procedure of insertion is as automated as possible; (5) ProtSqueeze is distributed for free under a general public license. In this work, we present the architecture and the algorithm of ProtSqueeze and demonstrate its usage in case studies.

  7. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  8. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  9. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  10. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  11. 48 CFR 552.211-89 - Non-manufactured wood packaging material for export.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Non-manufactured wood... and Clauses 552.211-89 Non-manufactured wood packaging material for export. As prescribed in 511.204(b)(4), insert the following clause: Non-Manufactured Wood Packaging Material for Export (JAN 2010) (a...

  12. ReSure Sealant for Pars Plana Vitrectomy Wound Closure.

    PubMed

    Ho, Vincent Y; Shah, Gaurav K; Liu, Enchun M

    2015-01-01

    ReSure Sealant (Ocular Therapeutix, Bedford, MA) is an ocular sealant that demonstrated both safety and effectiveness in a prospective, randomized clinical trial for sealing clear corneal incisions following cataract surgery and intraocular lens placement in adults.1 PATIENTS AND METHODS: This is the first literature report of ReSure Sealant used for the closure of 23-gauge (G) pars plana vitrectomy (PPV) sclerotomies. A 70-year-old pseudophakic female with a history of epiretinal membrane and branch retinal vein occlusion of the right eye underwent 23-G PPV, membrane peel, and air-fluid exchange and was found to have leaking subconjunctival air at the end of the case. A linear conjunctival incision was performed to access the sclerotomy site. The incisions were then carefully dried before the sealant was applied to seal both the sclera and conjunctiva. After polymerization, the sealant formed a polyethylene glycol (PEG) hydrogel that was 89% water and 9.44% PEG. PEG is a synthetic material that is non-toxic and inert and, thus, suitable for use in medical products. ReSure Sealant may be a safe, quick method to close sclerotomy wounds in select cases. [ Copyright 2015, SLACK Incorporated.

  13. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    PubMed

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  14. [Incremental effect and mechanism of cyclosporine on blood concentration of statins and statin package insert information in Japan].

    PubMed

    Hirata-Koizumi, Mutsuko; Saito, Mitsuo; Miyake, Shinji; Hasegawa, Ryuichi

    2005-01-01

    Cyclosporine is an indispensable immunosuppressant used in organ transplant patients, who frequently manifest hyperlipidemia. Statins, which are cholesterol-lowering agents, are often combined with cyclosporine in the treatment of hyperlipidemia of organ transplant patients. Since cyclosporine is a substrate and inhibitor of CYP3A4, researchers suspect that the immunosuppressant inhibits CYP3A4-mediated metabolism of statins, leading to an increase in statin plasma concentration and infrequently resulting in rhabdomyolysis. However, a number of clinical trials have shown cyclosporine to increase the plasma concentration of all developed statins, including those not metabolized by CYP3A4. Furthemore, recent mechanistic studies have shown organic anion transporting peptides (OATP) C to mediate the uptake of some statins and cyclosporine has been shown to inhibit the uptake via OATP-C in cultured cells. Therefore, the inhibition of hepatic uptake of statins is considered to be one of the mechanisms by which cyclosporine incrementally increases statin blood concentration. However, most current Japanese package inserts of statins give no information on change in pharmacokinetic parameters such as AUC and Cmax in the combined medication with cyclosporine. Furthermore, in the Japanese package inserts, it is either stated that cyclosporine inhibits CYP3A4-mediated metabolism or no comment is made on the mechanism. The package insert should properly provide available quantitative information on the change of pharmacokinetic parameters and the probable mechanism of action.

  15. CAUSES OF POOR SEALANT PERFORMANCE IN SOIL-GAS- RESISTANT FOUNDATIONS

    EPA Science Inventory

    The paper discusses causes of poor sealant performance in soil-gas-resistant foundations. ealants for radon-resistant foundation construction must seal the gap between concrete sections. odern sealants have such low permeability that seal performance depends only on the permeabil...

  16. Performance of concrete joint sealants in hot climates

    DOT National Transportation Integrated Search

    1987-11-01

    A research project was initiated in 1979 on project IR-17-1(126) to compare and evaluate several joint sealants. In 1982 another test section on project F 028-1-506 was established to evaluate several other sealants. This report documents the placeme...

  17. High performance channel injection sealant invention abstract

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.; Basiulis, D. I.; Salisbury, D. P. (Inventor)

    1982-01-01

    High performance channel sealant is based on NASA patented cyano and diamidoximine-terminated perfluoroalkylene ether prepolymers that are thermally condensed and cross linked. The sealant contains asbestos and, in its preferred embodiments, Lithofrax, to lower its thermal expansion coefficient and a phenolic metal deactivator. Extensive evaluation shows the sealant is extremely resistant to thermal degradation with an onset point of 280 C. The materials have a volatile content of 0.18%, excellent flexibility, and adherence properties, and fuel resistance. No corrosibility to aluminum or titanium was observed.

  18. Relation Between PAHs and Coal-Tar-Based Pavement Sealant in Urban Environments (Invited)

    NASA Astrophysics Data System (ADS)

    Mahler, B. J.; van Metre, P. C.

    2010-12-01

    Since 2003, coal-tar-based sealant products have come under increased scrutiny as a source of PAHs in urban environments. Sealant (or sealcoat) is the black, shiny substance often applied to asphalt pavement, in particular parking lots and driveways, for esthetic and maintenance purposes. Coal-tar-based sealant, one of the two primary pavement sealant types on the market, typically is 20-35 percent coal-tar pitch, a known carcinogen that is more than 50 percent polycyclic aromatic hydrocarbons (PAHs). The PAH content of the coal-tar-based sealant product is about 1,000 times that of a similar, asphalt-based product, on average. This difference is reflected in regional differences in sealant use and PAH concentrations in pavement dust. In the central and eastern U.S., where the coal-tar-based formulation is prevalent, ΣPAH in mobile particles from sealed pavement have been shown to be about 1,000 times higher than in the western U.S., where the asphalt-based formulation is prevalent (the median ΣPAH concentrations are 2,200 mg/kg in the central and eastern U.S. and 2.1 mg/kg in the western U.S.). Source apportionment modeling indicates that, in the central and eastern U.S., particles from sealed pavement are contributing the majority of the PAHs in recently deposited (post-1990) lake sediment, with implications for ecological health, and that coal-tar-based sealant is the primary cause of upward trends in PAHs in U.S. urban lakes. From the standpoint of human health, research indicates that mobile particles from parking lots with coal-tar-based sealant are tracked indoors, resulting in elevated PAH concentrations in house dust. Coal-tar-based sealcoat being applied to an asphalt parking lot at the University of Texas Pickle Research Center.

  19. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents.

    PubMed

    Ahovuo-Saloranta, A; Hiiri, A; Nordblad, A; Worthington, H; Mäkelä, M

    2004-01-01

    Fissure sealants used on occlusal tooth surfaces were introduced in the 1960s for protecting pits and fissures from dental caries. Although sealants have demonstrated to be effective in preventing caries, their efficacy may be related to the background caries prevalence in the population. The primary objective of this review was to evaluate the caries prevention of resin based pit and fissure sealants and glass ionomer cements or sealants in children and adolescents. We searched the Cochrane Oral Health Group's Trials Register (last update December 2002), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 4, 2002), MEDLINE via OVID (1966 to December 2002), EMBASE (1974 to February 2002), SCISEARCH, SIGLE, CAplus, INSPEC, JICST-EPLUS, NTIS, PASCAL (February 2002) and DARE, NHS EED, HTA (March 2002). Reference lists from included articles and review articles were searched for additional relevant articles. All relevant studies in most languages were considered and translated. Randomised or quasi-randomised controlled trials of at least 12 months in duration in which sealants were used for preventing caries in children and adolescents under 20 years of age were included. The primary outcome was the increment in the numbers of carious occlusal surfaces of premolars and molars. In the first phase, two reviewers independently examined whether a given study was likely to be relevant on the basis of the title, key words and abstract. In the second phase, four of the reviewers independently classified studies to be included in final analyses. Study authors were contacted for additional information. In the split-mouth studies relative risk ratios were calculated for the paired differences of tooth surfaces being carious or not. In studies comparing resin based sealant with no treatment, fixed effect meta-analyses were used to combine the estimates of relative risk ratios. In one parallel group study, the mean DFS data as continuous data, the effect estimate being the difference in mean DFS, was calculated from data of occlusal surfaces of teeth included in the test and control groups. Eight trials were included in this review of which seven trials were split-mouth studies and one a parallel group study. Six studies provided data for comparing sealant with no treatment and three studies for comparing glass ionomers with resin based sealants. The overall effectiveness of resin based sealants in preventing dental decay on first molars was high. Based on five split-mouth studies with 5 to 10 year old children there were significant differences in favour of the second-generation resin sealant compared with no treatment with pooled relative risk values of 0.14, 0.24, 0.30, 0.43 at 12, 24, 36 and 48 to 54 months respectively. The reductions in caries therefore ranged from 86% at 12 months to 57% at 48 to 54 months. The 24 month parallel group study comparing second-generation resin sealant with control in 12 to 13 year old children found also significantly more caries in the control group children with DFS = 0.65 (95% CI 0.47 to 0.83). Allocation concealment was classified adequate in three of these six studies. However the information on background levels of caries in the population was insufficient to conduct further analyses to estimate the effectiveness of resin based sealants related to baseline caries prevalence. Only one study provided data for the comparison between glass ionomer sealant and control. Based on this, there is not enough information to say whether ionomer sealants are effective, or not. The results of three studies comparing resin sealants with glass ionomer sealants were conflicting and the meta-analyses were not carried out. Sealing with resin based sealants is a recommended procedure to prevent caries of the occlusal surfaces of permanent molars. However, we recommend that the caries prevalence level of both individuals and the population should be taken into account. In practice, the benefit of sealing should be considered locally and specified guidelines for clinicians should be used. The methodological quality of published studies concerning pit and fissure sealants was poorer than expected.

  20. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation.

    PubMed

    Borges, Boniek Castillo Dutra; Pereira, Fabrício Lopes da Rocha; Alonso, Roberta Caroline Bruschi; Braz, Rodivan; Montes, Marcos Antônio Japiassú Resende; Pinheiro, Isauremi Vieira de Assunção; Santos, Alex José Souza dos

    2012-01-01

    We evaluated the influence of photoactivation method and hydrophobic resin (HR) application on the marginal and internal adaptation, hardness (KHN), and crosslink density (CLD) of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10) and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL), no adhesive system + photoactivation of the sealant using the soft-start method (SS), HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  1. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT andmore » BHA were detected in 39–67% of samples, at concentration ranges of« less

  2. Low-profile fiber connector for co-packaged optics

    NASA Astrophysics Data System (ADS)

    Brusberg, Lars; DeJong, Michael; Butler, Douglas L.; Clark, Jeffrey S.; Sutton, Clifford G.

    2018-02-01

    We developed a small form factor connector that can be assembled on all four sides of a high-data switch package for fiber connectivity. This paper discusses a novel connector approach that has the potential to meet all co-packaging requirements including solder-reflow-compatibility, de-mateability, low insertion loss and state-of-the art FAU attach. The connector was attached to the PIC for performance evaluation. The average insertion loss across all eight fibers of the assembly was 1.77 dB, including the three optical interfaces: (1) MT-to-MT between connector and receptacle, (2) receptacle-to-PLC and (3) PIC-to-FAU. Also included is the propagation loss of the PIC waveguide. Optical return loss was measured to be -55 dB or lower.

  3. Investigating crack sealant performance and causes of bumps in new hot mix asphalt overlays over crack sealants.

    DOT National Transportation Integrated Search

    2011-07-01

    This final report is intended to provide information regarding the performance of crack sealants supplied and installed by : three manufacturers for experimental use in a three-year evaluation of in-service pavements on three Colorado highways. : In ...

  4. Short-term crack sealant performance and reducing bumps and transverse cracking in new hot mix asphalt overlays over crack sealants.

    DOT National Transportation Integrated Search

    2009-11-01

    This interim report is intended to provide preliminary information regarding the performance of crack sealants produced by three : manufacturers during a two-year period in service in three pavements in Colorado. In addition, preliminary conclusions ...

  5. Construction and monitoring of thin overlay and crack sealant test sections at the Pecos test track.

    DOT National Transportation Integrated Search

    2014-10-01

    In this project, several crack sealant sections were constructed at the Pecos RTC. Six different sealants were : applied in routed and non-routed configurations on both older and newer pavement. The following summer, : the sections were revaluated in...

  6. Evidence-based clinical practice guideline for the use of pit-and-fissure sealants: A report of the American Dental Association and the American Academy of Pediatric Dentistry.

    PubMed

    Wright, John T; Crall, James J; Fontana, Margherita; Gillette, E Jane; Nový, Brian B; Dhar, Vineet; Donly, Kevin; Hewlett, Edmond R; Quinonez, Rocio B; Chaffin, Jeffrey; Crespin, Matt; Iafolla, Timothy; Siegal, Mark D; Tampi, Malavika P; Graham, Laurel; Estrich, Cameron; Carrasco-Labra, Alonso

    2016-08-01

    This article presents evidence-based clinical recommendations for the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. A guideline panel convened by the American Dental Association (ADA) Council on Scientific Affairs and the American Academy of Pediatric Dentistry conducted a systematic review and formulated recommendations to address clinical questions in relation to the efficacy, retention, and potential side effects of sealants to prevent dental caries; their efficacy compared with fluoride varnishes; and a head-to-head comparison of the different types of sealant material used to prevent caries on pits and fissures of occlusal surfaces. This is an update of the ADA 2008 recommendations on the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars. The authors conducted a systematic search in MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and other sources to identify randomized controlled trials reporting on the effect of sealants (available on the US market) when applied to the occlusal surfaces of primary and permanent molars. The authors used the Grading of Recommendations Assessment, Development, and Evaluation approach to assess the quality of the evidence and to move from the evidence to the decisions. The guideline panel formulated 3 main recommendations. They concluded that sealants are effective in preventing and arresting pit-and-fissure occlusal carious lesions of primary and permanent molars in children and adolescents compared with the nonuse of sealants or use of fluoride varnishes. They also concluded that sealants could minimize the progression of noncavitated occlusal carious lesions (also referred to as initial lesions) that receive a sealant. Finally, based on the available limited evidence, the panel was unable to provide specific recommendations on the relative merits of 1 type of sealant material over the others. These recommendations are designed to inform practitioners during the clinical decision-making process in relation to the prevention of occlusal carious lesions in children and adolescents. Clinicians are encouraged to discuss the information in this guideline with patients or the parents of patients. The authors recommend that clinicians reorient their efforts toward increasing the use of sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. Copyright © 2016 American Academy of Pediatric Dentistry and American Dental Association. Published by Elsevier Inc. All rights reserved.

  7. Cigarette package inserts can promote efficacy beliefs and sustained smoking cessation attempts: A longitudinal assessment of an innovative policy in Canada

    PubMed Central

    Thrasher, James F.; Swayampakala, Kamala; Cummings, K. Michael; Hammond, David; Anshari, Dien; Krugman, Dean M.; Hardin, James W.

    2016-01-01

    Background In June 2012, Canada implemented new pictorial warnings on cigarette packages, along with package inserts with messages to promote response efficacy (i.e., perceived quitting benefits) and self-efficacy (i.e., confidence to quit). This study assessed smokers’ attention towards warnings and inserts and its relationship with efficacy beliefs, risk perceptions and cessation at follow-up. Methods Data were analysed in 2015 from a prospective online consumer panel of adult Canadian smokers surveyed every four months between September 2012 and September 2014. Generalized Estimating Equation models assessed associations between reading inserts, reading warnings and efficacy beliefs (self-efficacy, response efficacy), risk perceptions, quit attempts of any length, and sustained quit attempts (i.e., 30 days or more) at follow-up. Models adjusted for socio-demographics, smoking-related variables, and time-in-sample effects. Results Over the study period, reading warnings significantly decreased (p<0.0001) while reading inserts increased (p=0.004). More frequent reading of warnings was associated independently with stronger response efficacy (Boften/very often vs never=0.28, 95% CI: 0.11–0.46) and risk perceptions at follow-up (Boften/very often vs never=0.31, 95% CI: 0.06–0.56). More frequent reading of inserts was associated independently with stronger self-efficacy to quit at follow-up (Btwice or more vs none=0.30, 95% CI: 0.14–0.47), quit attempts (ORtwice or more vs none= 1.68, 95% CI: 1.28–2.19), and quit attempts lasting 30 days or longer (ORtwice or more vs none=1.48, 95% CI: 1.01 – 2.17). Conclusions More frequent reading of inserts was associated with self-efficacy to quit, quit attempts, and sustained quitting at follow-up, suggesting that inserts complement pictorial HWLs. PMID:26970037

  8. Durability of building joint sealants

    Treesearch

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  9. The Maine Sealant Manual for School-Based and School-Linked Dental Sealant Programs.

    ERIC Educational Resources Information Center

    Hayward, Kneka, Ed.

    This manual is designed for use by school personnel and dental personnel to aid in the development and maintenance of school-based or school-linked dental sealant programs. The sections include (1) "Introduction"; (2) "Guidelines" (school selection, school contacts, dental providers, target grades, and tooth selection…

  10. Light weight phosphate cements

    DOEpatents

    Wagh, Arun S.; Natarajan, Ramkumar,; Kahn, David

    2010-03-09

    A sealant having a specific gravity in the range of from about 0.7 to about 1.6 for heavy oil and/or coal bed methane fields is disclosed. The sealant has a binder including an oxide or hydroxide of Al or of Fe and a phosphoric acid solution. The binder may have MgO or an oxide of Fe and/or an acid phosphate. The binder is present from about 20 to about 50% by weight of the sealant with a lightweight additive present in the range of from about 1 to about 10% by weight of said sealant, a filler, and water sufficient to provide chemically bound water present in the range of from about 9 to about 36% by weight of the sealant when set. A porous ceramic is also disclosed.

  11. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  12. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  13. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  14. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  15. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  16. Conformity of package inserts information to regulatory requirements among selected branded and generic medicinal products circulating on the East African market.

    PubMed

    Sillo, Hiiti B; Masota, Nelson E; Kisoma, Sunday; Rago, Lembit; Mgoyela, Veronica; Kaale, Eliangiringa A

    2018-01-01

    Availability of correct and adequate information about medicines is an important aspect in ensuring rational use of medicines and hence facilitating safety and expected efficacy of medicines during therapy. Package inserts have proven to be a good source of information to the prescribers and patients whereby they have been useful in highlighting important information pertaining proper use and handling of the medicines. The present study was aimed at establishing the extent to which package inserts of medicines circulating on the markets of the East African Community (EAC) Partner States conform to medicines information requirements as established in the harmonized guidelines as well as national guidelines. A total of 99 package inserts from six (6) types of medicines namely Albendazole, Artemether/Lumefantrine (ALu), Ciprofloxacin, Paracetamol, Amoxicillin and Metronidazole were purposefully collected from three EAC Partner States: Kenya, Tanzania and Uganda. The medicines were selected based on their indications as first line treatments, high rates of utilization within the medicines supply system and their positions in treatment of diseases of public importance across EAC Partner States. The inserts were evaluated on the availability of information regarding fifteen (15) parameters as extracted from the EAC harmonized guidelines for registration of medicines. Moreover, comparisons were made between the percentage conformity of the branded versus generic products, markets from which the samples were collected, origin of the manufacturer and type of medicine. Majority (93.9-100%) of the medicines' package inserts highly conformed to the inclusion of the information regarding the description and composition of the medications, indications, dosage and methods of administration, warnings and precautions, contraindications and storage conditions. However, the information on handling and disposal, container package description, excipients used, clinical pharmacology of the medicines, and directions regarding overdose ranked the least in conformance with conformity ranging from 13.1-52.5%. The parameter with the lowest observed percentage conformity among the branded products scored 50% as compared to 10.8% among the generic products. Moreover, there was no significant difference (P<0.05) in the percentage conformity of the package inserts collected from each of the three Partner States as compared to the average from studied medicines. A generally good conformity was observed among medicines manufactured by European based manufacturers as compared to those based in Asia and EAC Partner States. In addition, PIs of Albendazole, Ciprofloxacin, Amoxicillin and Artemether/Lumefantrine did show overall high conformity across most of the product information requirements. Our study revealed the existence of a significant number of medicinal products circulating on the markets of EAC Partner States without necessary compliance with all product information requirements. We therefore recommend that NMRAs ensure thorough pre-market assessment of product information as well as strengthening their post marketing surveillance to ensure that medicines circulating on the market comply to medicines information requirements at all times. Emphasis should also be given to manufacturers on the importance of inclusion of appropriate and adequate product information for the safety of patients, including advocating for inclusion of patient-friendly and easy to understand medicines information.

  17. Sealants in dentistry: a systematic review of the literature.

    PubMed

    Condò, R; Cioffi, A; Riccio, A; Totino, M; Condò, S G; Cerroni, L

    2013-03-01

    The occlusal surface is the most affected area by dental caries and the sealing of the pits and of the fissures has been found, in time, the preventive method most effective trying to counteract the onset. Currently, the WHO considers it as a primary preventive measure, in other words one of the most effective and least invasive available to ensure the complete protection and the total preservation of the occlusal carious by the phenomenon. THE AIM OF THIS WORK HAS BEEN TO PERFORM A SYSTEMATIC REVIEW OF THE LITERATURE ON CLINICAL TRIALS OF DIFFERENT SEALING MATERIALS, IN ORDER TO: compare their individual characteristics, highlight the reliability and the long-term efficacy and identify the most significant variables, both technological and clinics, in order to declare whether or not the success of this method prior. The research has been carried out in the MEDLINE database by choosing keywords as "sealants" and "follow up". Only studies published in the last thirteen years have been considered and have been evaluated only types of scientific articles that fall within the definition of Anglo-Saxon "Clinical Trial" and "Controlled Clinical Trial", excluding all experimental works in vitro, case-reports, meta-analyzes and literature reviews. Have been also considered only scientific papers on patients between the ages of 0 and 18 years. Out of 29 studies, evaluating a total of 2900 individuals (aged between 2.5 and 17 years), 7411 seals made by using resin-based sealants (RB Sealants), modified glass ionomer sealants (RMGI) and compomer sealants have been analyzed. The best retention capacity of the material in time has been obtained from the use of RB Sealants compared to RMGI, demonstrating retention values much lower with partial loss of material at a distance of one year from the clinic. The compomers demonstrate retention values intermediates. The incidence of caries in a year is negligible for all sealants application. In terms of retention, resin-based sealants (RB Sealants) are the materials that give more guarantees of success at 12 months, while in the same period there haven't been significant differences in caries prevention of disease among the various classes sealing materials analyzed.

  18. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts.

    PubMed

    Gillet, Philippe; Maltha, Jessica; Hermans, Veerle; Ravinetto, Raffaella; Bruggeman, Cathrien; Jacobs, Jan

    2011-02-13

    The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n=40) and (ii) ambiguous labelling of the reading window (n=6). Buffer vial labels were lacking essential information (n=24) or were of poor quality (n=16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1-12.9) and user-unfriendly typography (median font size 8, range 5-10). Inadequacies included (i) no referral to biosafety (n=18), (ii) critical differences between depicted and real devices (n=8), (iii) figures with unrealistic colours (n=4), (iv) incomplete information about RDT line interpretations (n=31) and no data on test characteristics (n=8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n=4), (ii) not stating the identity of the pan-species antigen (n=2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.

  19. First Permanent Molar Restoration Differences between Those with or without Dental Sealants.

    ERIC Educational Resources Information Center

    Kuthy, Raymond A.; And Others

    1990-01-01

    The study examined differences in the number of restorations in permanent, posterior teeth for those children receiving dental sealants with cost sharing when compared to children who do not receive sealants. Results indicated a 51 percent reduction in restoration rates for each quadrant sealed. Findings have implications for cost savings and…

  20. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  1. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  2. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and...

  3. 48 CFR 52.247-65 - F.o.b. Origin, Prepaid Freight-Small Package Shipments.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false F.o.b. Origin, Prepaid... Text of Provisions and Clauses 52.247-65 F.o.b. Origin, Prepaid Freight—Small Package Shipments. As prescribed in 47.303-17(f), insert the following clause: F.o.b. Origin Prepaid Freight—Small Package...

  4. The economics of pit and fissure sealants in preventive dentistry: a review.

    PubMed

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  5. Packaging double-helical DNA into viral capsids.

    PubMed

    LaMarque, Jaclyn C; Le, Thuc-Vy L; Harvey, Stephen C

    2004-02-15

    DNA packaging in bacteriophage P4 has been examined using a molecular mechanics model with a reduced representation containing one pseudoatom per turn of the double helix. The model is a discretized version of an elastic continuum model. The DNA is inserted piecewise into the model capsid, with the structure being reoptimized after each piece is inserted. Various optimization protocols were investigated, and it was found that molecular dynamics at a very low temperature (0.3 K) produces the optimal packaged structure. This structure is a concentric spool, rather than the coaxial spool that has been commonly accepted for so many years. This geometry, which was originally suggested by Hall and Schellman in 1982 (Biopolymers Vol. 21, pp. 2011-2031), produces a lower overall elastic energy than coaxial spooling. Copyright 2003 Wiley Periodicals, Inc.

  6. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    PubMed

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p <0.05), as well as deduction (a scale score of the HSRT; r=0.26, p <0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students.

  7. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    PubMed Central

    Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students’ scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman’s rho correlation test was performed. Results. A very weak but significant positive correlation was found between students’ grades on the assignment and their overall HSRT score (r=0.19, p<0.05), as well as deduction (a scale score of the HSRT; r=0.26, p<0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students. PMID:28381884

  8. Influence of etching time and bonding strategies on the microshear bond strength of self- and light-cured pit-and-fissure sealants.

    PubMed

    Souza-Junior, Eduardo José; Borges, Boniek Castillo Dutra; Montes, Marcos Antônio Japiassú Resende; Alonso, Roberta Caroline Bruschi; Ambrosano, Glaucia Maria Bovi; Sinhoreti, Mário Alexandre Coelho

    2012-01-01

    This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.

  9. A highly adhesive and naturally derived sealant.

    PubMed

    Assmann, Alexander; Vegh, Andrea; Ghasemi-Rad, Mohammad; Bagherifard, Sara; Cheng, George; Sani, Ehsan Shirzaei; Ruiz-Esparza, Guillermo U; Noshadi, Iman; Lassaletta, Antonio D; Gangadharan, Sidhu; Tamayol, Ali; Khademhosseini, Ali; Annabi, Nasim

    2017-09-01

    Conventional surgical techniques to seal and repair defects in highly stressed elastic tissues are insufficient. Therefore, this study aimed to engineer an inexpensive, highly adhesive, biocompatible, and biodegradable sealant based on a modified and naturally derived biopolymer, gelatin methacryloyl (GelMA). We tuned the degree of gelatin modification, prepolymer concentration, photoinitiator concentration, and crosslinking conditions to optimize the physical properties and adhesion of the photocrosslinked GelMA sealants. Following ASTM standard tests that target wound closure strength, shear resistance, and burst pressure, GelMA sealant was shown to exhibit adhesive properties that were superior to clinically used fibrin- and poly(ethylene glycol)-based glues. Chronic in vivo experiments in small as well as translational large animal models proved GelMA to effectively seal large lung leakages without the need for sutures or staples, presenting improved performance as compared to fibrin glue, poly(ethylene glycol) glue and sutures only. Furthermore, high biocompatibility of GelMA sealant was observed, as evidenced by a low inflammatory host response and fast in vivo degradation while allowing for adequate wound healing at the same time. Combining these results with the low costs, ease of synthesis and application of the material, GelMA sealant is envisioned to be commercialized not only as a sealant to stop air leakages, but also as a biocompatible and biodegradable hydrogel to support lung tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Evaluation of a hydrophilic gingival dental sealant in beagle dogs.

    PubMed

    Sitzman, Clarence

    2013-01-01

    A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p < 0.05) reduced on the side receiving the sealant by 30.0% and 50.5% (average = 40.3%) in groups 1 and 2, respectively. Calculus was significantly (p < 0.05) reduced on the side receiving the sealant by 27.2% and 20.0% (average = 23.6%) in groups 1 and 2, respectively. Gingival inflammation was monitored to assess product safety. Sides receiving sealant showed no statistically significant differences in gingival index score. No adverse events were observed in the study. This study demonstrates that this gingival sealant can be used as another valuable tool for aiding in the prevention of periodontal disease in dogs.

  11. Systematic review and meta-analysis of fibrin sealants for patients undergoing pancreatic resection

    PubMed Central

    Orci, Lorenzo A; Oldani, Graziano; Berney, Thierry; Andres, Axel; Mentha, Gilles; Morel, Philippe; Toso, Christian

    2014-01-01

    Introduction Post-operative pancreatic fistula (POPF) is a common complication after partial pancreatic resection, and is associated with increased rates of sepsis, mortality and costs. The role of fibrin sealants in decreasing the risk of POPF remains debatable. The aim of this study was to evaluate the literature regarding the effectiveness of fibrin sealants in pancreatic surgery. Methods A comprehensive database search was conducted. Only randomized controlled trials comparing fibrin sealants with standard care were included. A meta-analysis regarding POPF, intra-abdominal collections, post-operative haemorrhage, pancreatitis and wound infections was performed according to the recommendations of the Cochrane collaboration. Results Seven studies were included, accounting for 897 patients. Compared with controls, patients receiving fibrin sealants had a pooled odds ratio (OR) of developing a POPF of 0.83 [95% confidence interval (CI): 0.6–1.14], P = 0.245. There was a trend towards a reduction in post-operative haemorrhage (OR = 0.43 (95%CI: 0.18–1.0), P = 0.05) and intra-abdominal collections (OR = 0.52 (95%CI: 0.25–1.06), P = 0.073) in those patients receiving fibrin sealants. No difference was observed in terms of mortality, wound infections, re-interventions or hospital stay. Conclusion On the basis of these results, fibrin sealants cannot be recommended for routine clinical use in the setting of pancreatic resection. PMID:23461684

  12. Cotton roll isolation versus Vac-Ejector isolation.

    PubMed

    Wood, A J; Saravia, M E; Farrington, F H

    1989-01-01

    A visible-light-cured, white pit-and-fissure sealant was applied to 523 teeth in school children using either cotton rolls or a VacEjector for isolation. After a minimum of six months, the patients were recalled and the retention of the sealants was evaluated. No significant difference in sealant retention was found between the two isolation methods.

  13. Adhesion mechanisms of bituminous crack sealant to aggregate and laboratory test development

    NASA Astrophysics Data System (ADS)

    Hajialiakbari Fini, Elham

    Crack sealing is a common pavement maintenance treatment because it extends pavement service life. However, crack sealant often fails prematurely due to a loss of adhesion. Since current test methods are mostly empirical and only provide a qualitative measure of bond strength, they cannot predict sealant adhesive failure accurately. Hence, there is an urgent need for test methods based on bituminous sealant rheology that can better predict sealant field performance. This study introduces three laboratory tests aimed to assess the bond property of hot-poured crack sealant to pavement crack walls. The three tests are designed to serve the respective needs of producers, engineers, and researchers. The first test implements the principle of surface energy to measure the thermodynamic work of adhesion, which is the energy spent in separating the two materials at the interface. The work of adhesion is reported as a measure of material compatibility at an interface. The second test is a direct adhesion test, a mechanical test which is designed to closely resemble both the installation process and the crack expansion due to thermal loading. This test uses the Direct Tension Test (DTT) device. The principle of the test is to apply a tensile force to detach the sealant from its aggregate counterpart. The maximum load, Pmax, and the energy to separation, E, are calculated and reported to indicate interface bonding. The third test implements the principles of fracture mechanics in a pressurized circular blister test. The apparatus is specifically designed to conduct the test for bituminous crack sealant, asphalt binder, or other bitumen-based materials. In this test, a fluid is injected at a constant rate at the interface between the substrate (aggregate or a standard material) and the adhesive (crack sealant) to create a blister. The fluid pressure and blister height are measured as functions of time; the data is used to calculate Interfacial Fracture Energy (IFE), which is a fundamental property that can be used to predict adhesion. The stable interface debonding process makes this test attractive. This test also may be used to estimate the optimum annealing time, and to quantify other interface characteristics, such as the moisture susceptibility of a bond. In addition, the elastic modulus of the sealant and its residual stresses can be determined analytically. While the direct adhesion test is proposed as part of newly-developed performance-based guidelines for the selection of hot-poured crack sealant, the blister test may be used to estimate the optimum annealing time, in addition to IFE determination.

  14. Caries preventive efficacy of silver diammine fluoride (SDF) and ART sealants in a school-based daily fluoride toothbrushing program in the Philippines.

    PubMed

    Monse, Bella; Heinrich-Weltzien, Roswitha; Mulder, Jan; Holmgren, Christopher; van Palenstein Helderman, Wim H

    2012-11-21

    Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries.The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard ratios reached statistical significance for the non-treated children (HR 0.43; 0.21-0.87) and the sealant-treated children (HR 0.15; 0.03-0.072). A one-time application of 38% SDF on the occlusal surfaces of permanent first molars of six- to eight-year-old children is not an effective method to prevent dentinal (D3) caries lesions. ART sealants significantly reduced the onset of caries over a period of 18 months. German Clinical Trial Register DRKS00003427.

  15. Caries preventive efficacy of silver diammine fluoride (SDF) and ART sealants in a school-based daily fluoride toothbrushing program in the Philippines

    PubMed Central

    2012-01-01

    Background Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries. The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. Methods The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. Results In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard ratios reached statistical significance for the non-treated children (HR 0.43; 0.21-0.87) and the sealant-treated children (HR 0.15; 0.03-0.072). Conclusions A one-time application of 38% SDF on the occlusal surfaces of permanent first molars of six- to eight-year-old children is not an effective method to prevent dentinal (D3) caries lesions. ART sealants significantly reduced the onset of caries over a period of 18 months. Trial registration number German Clinical Trial Register DRKS00003427 PMID:23171244

  16. Withstand pressure of a simple fibrin glue sealant: experimental study of mimicked sellar reconstruction in extended transsphenoidal surgery.

    PubMed

    Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki

    2010-06-01

    To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. Selective removal of composite sealants with near-UV laser pulses

    NASA Astrophysics Data System (ADS)

    Louie, Tiffany M.; Jones, Robert S.; Sarma, Anupama V.; Fried, Daniel

    2004-05-01

    It is often necessary to replace pit and fissure sealants and composite restorations. This task is complicated by the necessity for complete removal of the remaining composite to enable suitable adhesion of new composite. Previous studies have shown that lasers pulses from a frequency-tripled Nd:YAG laser (355-nm) can selectively remove residual composite after orthodontic bracket removal on enamel surfaces. UV laser light is preferentially absorbed by polymeric resins and the organic content of the tooth enamel. The objective of this study was to determine if such laser pulses are suitable for selective removal of the old composite from pit and fissure sealants and restorations without damaging surrounding sound tissues. Optical coherence tomography was used to acquire optical cross sections of the occlusal topography and peripheral tooth structure non-destructively before application of the sealants, after sealant application, and after sealant removal with 355-nm laser pulses with intensities ranging from 0-10 J/cm2. Thermocouples were used to monitor the temperature in the pulp chamber during composite removal under clinically relevant ablation rates, i.e., 30 Hz and 30 mJ per laser pulse. At an irradiation intensity of 1.3 J/cm2 pit and fissure sealants were completely removed without visible damage to the underlying enamel. At intensities above 1.5 J/cm2, the laser removes the resin layer while at the same time preferentially etching the surface of the enamel. Temperature excursions in the pulp chamber of extracted teeth was limited to less than 5°C if air-cooling was used during the rapid removal (1-2 min) of sealants, water-cooling was not needed. This is the first presentation of a method for the selective removal of composite restorative materials without damage to the underlying sound tooth structure.

  18. Sealing occlusal caries lesions in adults referred for restorative treatment: 2-3 years of follow-up.

    PubMed

    Bakhshandeh, Azam; Qvist, Vibeke; Ekstrand, Kim R

    2012-04-01

    The aim of this study was to assess the possibility to arrest occlusal caries lesions in adults by sealant as well as to assess the presence of radiographic progression, arrest, and regression of the sealed lesions. Seventy-two occlusal caries lesions in 52 adult patients referred to restorative treatment by senior lecturers at School of Dentistry, Copenhagen, Denmark were included. In case the patient had more than one occlusal caries lesion, randomization between sealing and restoration was made; otherwise, the lesion was sealed. In total, 60 resin sealants and 12 composite restorations were made. Follow-up period was 25-38 months (mean = 33 months). Data were analyzed using non-parametric statistics including kappa statistics. After 2-3 years, the dropout rate was 15%; two patients did not show up for control and nine previously sealed lesions were restored by the patients' general practitioners. All 12 restorations and 39 of the remaining 49 sealants were well functioning, seven (14%) sealants were repaired/replaced due to failure, and three (6%) sealed lesions were restored due to caries progression (p > 0.05). The radiographic assessment showed caries progression beneath five (10%) sealants, caries regression beneath one (2%) sealant, and unchanged depth beneath 43 (88%) sealants and all restorations (p > 0.05). The majority of the referred lesions were successfully arrested by sealants, indicating the possibility for extending the criteria for sealing occlusal caries lesions in adults. However, a longer observation period is needed for final conclusion. Extending the criteria of therapeutic sealing of occlusal caries lesions in adults will lead to increased dental health.

  19. Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.

    PubMed

    Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C

    2013-07-01

    Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.

  20. Design, development, and testing of a hybrid in situ testing device for building joint sealant

    Treesearch

    C. White; N. Embree; C. Buch; R.S. Williams

    2005-01-01

    The testing of sealant samples has been restricted to devices that either focus on fatiguing multiple samples or quantifying the mechanical properties of a single sample. This manuscript describes a device that combines these two instrumental designs: the ability to both fatigue and characterize multiple sealant samples at the same time. This device employs precise...

  1. Primary care research: difficulties recruiting preschool children to clinical trials.

    PubMed

    Chadwick, B L; Treasure, E T

    2005-05-01

    The aims of the present study were to report difficulties experienced recruiting preschool children to a clinical trial and to report the acceptability of a dental intervention to their parents. The study was a randomized controlled trial (RCT). The study took place in community dental clinics, health centres and patient homes. Health visitors were used to recruit 508 children aged between 18 and 30 months from high caries areas of South Wales. Children with caries-free first primary molars were entered into a placebo-controlled individual RCT of fissure sealants. All children received a standard package of dental health education. Children in the test group had their first primary molars sealed with glass ionomer. All children were reviewed once. Families were asked to rate the acceptability of procedures. Health visitors referred 1228 children for screening, but only 547 were seen (44.5%) and 508 subjects were recruited to the trial. Of these, 449 (88.4%) were seen at follow-up. Some 667 children missed 1610 visits at baseline, and 373 of those recruited missed an appointment. At follow-up, 1056 appointments were staffed to review 449 children. Three-quarters of parents reported the examination to be very easy. Preschool children are difficult to access for community trials. Dental examinations and sealant placement were acceptable to the majority of families who were seen.

  2. Systematic review and meta-analysis of haemostatic and biliostatic efficacy of fibrin sealants in elective liver surgery.

    PubMed

    Sanjay, Pandanaboyana; Watt, David G; Wigmore, Stephen J

    2013-04-01

    Fibrin sealants are frequently used in liver surgery to achieve intraoperative haemostasis and reduce post-operative haemorrhage and bile leak. This meta-analysis aimed to review the haemostatic and biliostatic capacity of fibrin sealants in elective liver surgery. An electronic search was performed on the MEDLINE, Embase and PubMed databases using both subject headings and truncated word searches to identify all published articles that are related to this topic. Pooled risk ratios were calculated for categorical outcomes, and mean differences for secondary continuous outcomes, using the fixed-effects and random-effects models for meta-analysis. Ten randomised controlled trials encompassing 1,225 patients were analysed to achieve a summated outcome. Pooled data analysis showed the use of fibrin sealants resulted in reduced time to haemostasis (mean difference -3.45 min [-3.78, -3.13] (P < 0.00001)) and increased numbers of patients with complete haemostasis (risk ratio 1.56, 95 % confidence interval 1.04-2.34, p = 0.03) when compared to controls. The use of fibrin sealants did not influence perioperative blood transfusion requirements, bile leak rates, post-operative haemorrhage, intra-abdominal collections and overall morbidity and mortality compared with controls. There is no solid evidence that the routine use of fibrin sealants reduces the incidence of post-operative haemorrhage or bile leak compared with other treatments. The use of fibrin sealants may reduce the time to haemostasis, but this does not translate to improved perioperative outcomes.

  3. Dental sealants and flowable composite restorations and psychosocial, neuropsychological, and physical development in children.

    PubMed

    Maserejian, Nancy N; Shrader, Peter; Trachtenberg, Felicia L; Hauser, Russ; Bellinger, David C; Tavares, Mary

    2014-01-01

    Dental sealant materials may intraorally release their components, including bisphenol-A (BPA), but long-term health effects are uncertain. The New England Children's Amalgam Trial (NECAT) found that composite restorations were associated with psychosocial, but not neuropsychological or physical, outcomes. The previous analysis did not consider sealants and preventive resin restorations (PRRs), which were routinely placed. The purpose of this analysis was to examine sealant/PRR exposure in association with psychosocial and other health outcomes. NECAT recruited 534 six- to 10-year-olds and provided dental care during a five-year follow-up. Annually, examiners conducted psychosocial and neuropsychological tests and measured body mass index (BMI) and fat percentage (BF%). Associations between surface years (SY) of sealants/PRRs and outcomes were tested using multivariable models. Cumulative exposure level to sealants and/or PRRs was not associated with psychosocial assessments (eg, total problems: Child Behavior Checklist, 10-SY β=-0.2 ± 0.3, P=.60) or neuropsychological tests (eg, full-scale IQ, 10-SY β=0.1 ± 0.2, P=.60). There were no associations for changes in BMI-for-age z-score (P=.40), BF% (girls 10-SY β=-0.2 ± 0.3; boys 10-SY β=-0.1 ± 0.3), or menarche (10-SY hazard ratio=0.91, 95% confidence interval=0.83-1.01, P=.08). This study showed no associations between exposure level of dental sealants or PRRs and behavioral, neuropsychological, or physical development in children over 5-years.

  4. Tensile strength of biological fibrin sealants: a comparative study.

    PubMed

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Pilot Fullerton uses water dispenser kit gun to rehydrate food package

    NASA Image and Video Library

    1982-03-30

    STS003-26-254 (30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (ASSY) mini-headset (HDST), inserts the JSC water dispenser kit water gun in rehydratable plastic food (cereal) package to fill it with hot water. Photo credit: NASA

  6. Transparent and robust siloxane-based hybrid lamella film as a water vapor barrier coating.

    PubMed

    Tokudome, Yasuaki; Hara, Takaaki; Abe, Risa; Takahashi, Masahide

    2014-11-12

    Water vapor barriers are important in various application fields, such as food packaging and sealants in electronic devices. Polymer/clay composites are well-studied water vapor barrier materials, but their transparency and mechanical strength degrade with increasing clay loading. Herein, we demonstrate films with good water vapor barrier properties, high transparency, and mechanical/thermal stability. Water vapor barrier films were prepared by the solution crystallization of siloxane hybrid lamellae. The films consist of highly crystallized organic/inorganic hybrid lamellae, which provide high transparency, hardness, and thermal stability and inhibit the permeation of water vapor. The water permeability of a 6 μm thick hybrid film is comparable to that of a 200 μm thick silicon rubber film.

  7. Health Instruction Packages: Specific Nursing Skills.

    ERIC Educational Resources Information Center

    Bates, Clarice; And Others

    Text, illustrations, and exercises are utilized in a set of five learning modules designed to instruct nursing students in a variety of clinical skills. The first module, "Down the Tube: Insertion of a Nasogastric Tube" by Clarice Bates, describes materials and procedures used to insert a nasogastric tube through the nose and esophagus…

  8. Pneumostasis of experimental air leaks with a new photopolymerized synthetic tissue sealant.

    PubMed

    Ranger, W R; Halpin, D; Sawhney, A S; Lyman, M; Locicero, J

    1997-09-01

    Air leak is a major contributor to increased length of stay and postoperative morbidity following pulmonary surgery. The effectiveness of a new photopolymerized synthetic hydrogel (FocalSeal, Focal, Inc., Lexington, MA) as a sealant for pulmonary air leaks was determined in 10 mongrel dogs (20-35 kg). The animals were anesthetized and underwent left-sided anterolateral thoracotomy with amputation of a 2 x 3-cm segment of the lung apex. Hemostasis was achieved and terminal bronchial openings of 1.5 to 3 mm with vigorous air leaks were identified. After successful injury, the dogs were randomly assigned to sealant (n = 5) or control (n = 5) groups. In treated animals, the sealant was applied by brushing the solution to the cut parenchymal surface and solidified while briefly interrupting ventilation (40-60 seconds) using visible illumination (450-550 nm) from a xenon light source. Controls received no sealant. A single chest tube was maintained at the injury site with a continuous negative pressure of 20 cm of water. All dogs were extubated and allowed to breathe spontaneously under sedation for 24 hours. Chest radiographs were taken postsurgery and presacrifice. All control animals (n = 5) showed persistent vigorous air leak for the duration of the 24-hour observation period. All treated air leaks resolved immediately, and four of five remained sealed throughout the observation period. One leak reappeared after 17 hours due to inadequate sealant thickness over a 3-mm terminal bronchus. Gross evaluation of the treatment group at the end of 24 hours demonstrated intact sealant well adherent to the parenchyma. No evidence of atelectasis or excessive edema was seen, and no sealant-related complications or toxic effects were noted. Radiologically, lungs were fully inflated. Histologic evaluation at 24 hours revealed no evidence of a strong cellular response to the synthetic sealant, and no fibrosis or adhesions were seen, the onset of the healing process was favorable, indicating good biocompatability. In conclusion, this material was found to be an effective means for sealing bronchial and parenchymal air leaks in this model and warrants clinical evaluation.

  9. In-vivo durability of a fluoride-releasing sealant (OpalSeal) for protection against white-spot lesion formation in orthodontic patients.

    PubMed

    Knösel, Michael; Ellenberger, David; Göldner, Yvonne; Sandoval, Paulo; Wiechmann, Dirk

    2015-04-15

    Sealant application during fixed appliances orthodontic treatment for enamel protection is common, however, reliable data on its durability in vivo are rare. This study aims at assessing the durability of a sealant (OpalSeal, Ultradent) for protection against white-spot lesion formation in orthodontic patients over 26 weeks in vivo, taking into account the provision or absence of an adequate oral hygiene. We tested the null hypothesis of (1) no significant abatement of the sealant after 26 weeks in fixed orthodontic treatment compared to baseline, and (2) no significant influence of the factor of brushing and oral hygiene (as screened by approximal plaque index, API) on the abatement of the sealant. Integrity and abatement of OpalSeal applicated directly following bracketing was assessed in thirty-six consecutive patients (n(teeth) = 796) undergoing orthodontic treatment with fixed appliances (male/female 12/24; mean age/SD 14.4/1.33 Y). Assessment of the fluorescing sealant preservation was by a black-light lamp, using a classification that was concepted in analogy to the ARI index: (3, sealant completely preserved; 2= > 50% preserved; 1 = <50%; 0 = no sealant observable) immediately following application (Baseline, T0), after 2 (T1), 8 (T2), 14 (T3), 20 (T4) and 26 weeks (T5). API was assessed at T0 and T1. Statistical analysis was by non-parametric repeated measures ANOVA (α = 5%, power >80%). At baseline, 43.4% of teeth had a positive API. Oral hygiene deteriorated after bracketing (T1, 53%) significantly. Null hypothesis (1) was rejected, while (2) was accepted: Mean values of both the well brushed and non-brushed anterior teeth undercut the score "1" at T3 (week 14). Despite a slightly better preservation of the sealer before and after T3 in not-sufficiently brushed (API-positive) teeth, this finding was statistically not significant. One single application of OpalSeal is unlikely to last throughout the entire fixed appliance treatment stage. On average, re-application of the sealant can be expected to be necessary after 3.5 months (week 14) in treatment.

  10. Estimating emissions from adhesives and sealants uses and manufacturing for environmental risk assessments.

    PubMed

    Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten

    2016-01-01

    Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry (FEICA) SPERCs are available in several exposure assessment tools that are used under REACH. Given the limited regional variation in the manufacturing and use processes of adhesives and sealants, the SPERCs may be applicable for emission estimation not only in the EU but also in other regions. © 2015 SETAC.

  11. Dual Use of Packaging on the Moon: Logistics-2-Living

    NASA Technical Reports Server (NTRS)

    Howe, A. Scott; Howard, Robert

    2010-01-01

    This paper describes a modular packaging system for logistics that can be reconfigured into internal outfitting for a lunar outpost, including desks, chairs, partitions, cabinets, and radiation shielding. Logistics include clothes, equipment, food, and other consumables needed to sustain the crew for the duration of the mission. A significant mass penalty is required for the packaging and handling of logistics for re-supply of short to long-term space missions that must be brought out of the gravity well on a launch vehicle. Once the supplies have been exhausted, the packaging material is typically of no further use and is discarded. If a scheme can be developed that reuses the logistics packaging, the mass penalty can be reduced. In this research, a modular packaging system has been devised as a kit-of-parts that can be used for both handling logistics supplies, and then reconfigured into desks, chairs, partitions, cabinets, and radiation shielding. The system is derived from a standard International Space Station (ISS)-type Cargo Transfer Bag (CTB), using soft, unfoldable box-like containers with stiff metal inserts. The empty hydrogen-impregnated CTBs can be used as-is for cabinets, opened up for use as partitions, or draped over the habitat as layers of radiation shielding. Stiff metal inserts can be reconfigured into desks and other useful outfitting.

  12. The effect of internal teat sealant products (Teatseal and Orbeseal) on intramammary infection, clinical mastitis, and somatic cell counts in lactating dairy cows: a meta-analysis.

    PubMed

    Rabiee, A R; Lean, I J

    2013-01-01

    The objective of this study was to assess the efficacy of internal teat sealant products containing bismuth subnitrate (Teatseal and Orbeseal; Pfizer Animal Health, West Ryde, Australia) when used alone, or in the presence of antibiotic dry cow therapy (ADCT), before or at drying off on the incidence of new intramammary infections (IMI), clinical mastitis, and milk somatic cell count (SCC) during lactation. The literature search identified 18 English-language publications on the use of Teatseal in dairy cattle. A total of 12 studies with 17 subtrials or comparisons including 13 positive control subtrials (internal teat sealant and ADCT vs. ADCT) and 4 negative control subtrials (internal teat sealant vs. untreated) examining IMI were included in the analysis. Internal teat sealants, alone or in the presence of ADCT, reduced the risk of acquiring new IMI after calving by 25% [risk ratio (RR)=0.75; 95% confidence interval (CI): 0.67 to 0.83]. Internal teat sealants reduced the risk of IMI by 73% compared with untreated cows (RR=0.27; 95% CI: 0.13 to 0.55). The results of both meta-analyses of IMI, with positive and negative controls, were heterogeneous [I(2) (a statistic that describes the proportion of total variation in study effect estimates that is due to heterogeneity)=65.4 and 92.1%]. No farm or cow factors studied significantly contributed to the heterogeneity of the results. A total of 16 studies (21 subtrials), including 14 positive control subtrials and 7 negative control subtrials, examining clinical mastitis were included in the analysis. Internal teat sealants alone and in the presence of ADCT reduced the risk of clinical mastitis after calving in lactating cows by 29% (RR=0.71; 95% CI: 0.62 to 0.82), and 48% (RR=0.52; 95% CI: 0.37 to 0.75), respectively. The results of the meta-analysis on clinical mastitis with positive controls were homogeneous (I(2)=33.6%), whereas the results of studies with negative controls were heterogeneous (I(2)=60.4%). No farm or cow factors studied that had sufficient data to evaluate significantly contributed to the heterogeneity of the results. The estimated linear score (LS) of milk SCC after calving in published studies (n=3) and for studies that provided raw data (n=2), was significantly lower for cattle treated with internal teat sealants and ADCT in 3 studies than for cattle treated with internal teat sealants only. The estimated LS of pooled raw data of 3 studies from 32 herds showed that the LS of cows treated with internal teat sealant and ADCT was not significantly different than those treated with ADCT only. This study found that the application of internal teat sealants in the presence of ADCT or the use of internal teat sealants alone at dry off significantly reduced the incidence of IMI and clinical mastitis in lactating dairy cows compared with respective control groups. Further studies are needed to investigate the effect of internal teat sealants on postpartum milk SCC in lactating dairy cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

    NASA Astrophysics Data System (ADS)

    Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward

    1993-08-01

    A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

  14. Current oral contraceptive use instructions: an analysis of patient package inserts.

    PubMed

    Williams-Deane, M; Potter, L S

    1992-01-01

    Oral contraceptive use instructions contained in manufacturers' patient package inserts (PPIs) are often inconsistent or conflicting, both among manufacturers and among different brands and regimens from the same manufacturer. Instructions on what to do about missed pills are often incomplete or inadequate, as are instructions on backup contraceptive use when pills are missed. The format of many PPIs is confusing and makes instructions difficult to find and read. Comprehending the PPIs requires the user to read at a 10th-12th-grade level, far higher than the generally accepted 5th-6th grade level considered standard for health education materials.

  15. Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

    NASA Technical Reports Server (NTRS)

    Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward

    1993-01-01

    A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

  16. Microleakage and penetration depth of different fissure sealant materials after cyclic thermo-mechanic and brushing simulation.

    PubMed

    Hatirli, Hüseyin; Yasa, Bilal; Yasa, Elif

    2018-01-30

    The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.

  17. Recalcitrant Epithelial Ingrowth After SMILE Treated With a Hydrogel Ocular Sealant.

    PubMed

    Thulasi, Praneetha; Kim, Sang Woo; Shetty, Rohit; Randleman, J Bradley

    2015-12-01

    To report a case of recalcitrant epithelial ingrowth after small incision lenticule extraction (SMILE) treated successfully with a novel hydrogel ocular sealant. Case report and literature review. A 32-year-old man who underwent small incision lenticule extraction (SMILE) complicated by difficult lenticule extraction developed visually significant epithelial ingrowth. He then underwent two flap lifts and epithelial scrapings and flap edge suturing with recurrence of epithelial ingrowth despite these interventions. He subsequently underwent repeat scraping, followed by hydrogel ocular sealant placement (ReSure Sealant; Ocular Therapeutix, Inc., Bedford, MA), which prevented recurrence of epithelial ingrowth and reduced corneal haze. The patient was also found to have undiagnosed diabetes, suggesting that just as in LASIK, diabetes may be a risk factor for epithelial ingrowth after SMILE. Interface epithelial ingrowth is a potential complication after SMILE and diabetes may be a risk factor for this complication. Hydrogel ocular sealant may be effective after SMILE to prevent epithelial ingrowth into the interface. Copyright 2015, SLACK Incorporated.

  18. Evaluation of Solubility and Microleakage of Glass Carbomer Sealant.

    PubMed

    Subramaniam, P; Girish Babu, K L; Jayasurya, S

    2015-01-01

    This study was carried out to evaluate and compare solubility and microleakage of the newly introduced moisture tolerant glass carbomer sealant. For evaluation of solubility, 20 specimens of glass carbomer and conventional glass ionomer were prepared and immersed in artificial saliva of pH 4 and 6 for seven days. The difference between initial and final weight was calculated. For evaluation of microleakage, glass carbomer was compared with a conventional resin sealant. 20 premolar teeth indicated for orthodontic extraction were collected and divided into two groups and the respective sealants were applied. It was subjected to thermocycling and then kept immersed in methylene blue for 24 hours. Dye penetration was scored. The glass carbomer specimens were less soluble than the conventional glass ionomer at both pH values. There was no significant difference in the microleakage. Being moisture resistant, glass carbomer can be used as an alternative fissure sealant material; especially in young children with partially erupted teeth and where obtaining moisture control is difficult.

  19. Near-infrared imaging of demineralization under sealants

    NASA Astrophysics Data System (ADS)

    Tom, Henry; Simon, Jacob C.; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel

    2014-07-01

    Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.

  20. Near-infrared imaging of demineralization under sealants.

    PubMed

    Tom, Henry; Simon, Jacob C; Chan, Kenneth H; Darling, Cynthia L; Fried, Daniel

    2014-01-01

    Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.

  1. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    PubMed Central

    2011-01-01

    Background The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Methods Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Results Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. Conclusion Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information. PMID:21314992

  2. Marginal microleakage of triage sealant under different moisture contamination.

    PubMed

    Peng, Yawen; Stark, Paul C; Rich, Alfred; Loo, Cheen Y

    2011-01-01

    Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

  3. Influence of Delivery Method on Neuroprotection by Bone Marrow Mononuclear Cell Therapy following Ventral Root Reimplantation with Fibrin Sealant

    PubMed Central

    Barbizan, Roberta; Castro, Mateus V.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2014-01-01

    The present work compared the local injection of mononuclear cells to the spinal cord lateral funiculus with the alternative approach of local delivery with fibrin sealant after ventral root avulsion (VRA) and reimplantation. For that, female adult Lewis rats were divided into the following groups: avulsion only, reimplantation with fibrin sealant; root repair with fibrin sealant associated with mononuclear cells; and repair with fibrin sealant and injected mononuclear cells. Cell therapy resulted in greater survival of spinal motoneurons up to four weeks post-surgery, especially when mononuclear cells were added to the fibrin glue. Injection of mononuclear cells to the lateral funiculus yield similar results to the reimplantation alone. Additionally, mononuclear cells added to the fibrin glue increased neurotrophic factor gene transcript levels in the spinal cord ventral horn. Regarding the motor recovery, evaluated by the functional peroneal index, as well as the paw print pressure, cell treated rats performed equally well as compared to reimplanted only animals, and significantly better than the avulsion only subjects. The results herein demonstrate that mononuclear cells therapy is neuroprotective by increasing levels of brain derived neurotrophic factor (BDNF) and glial derived neurotrophic factor (GDNF). Moreover, the use of fibrin sealant mononuclear cells delivery approach gave the best and more long lasting results. PMID:25157845

  4. Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.

    PubMed

    Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E

    2012-03-01

    The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p < 0.05). No differences were observed in μTBS of Helioseal F and Helioseal Clear (p > 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p < 0.05). However, no significant differences were found between the μTBS values of the adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.

  5. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    PubMed

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  6. A Chitosan-Based Sinus Sealant for Reduction of Adhesion Formation in Rabbit and Sheep Models

    PubMed Central

    Medina, Jennifer G.; Steinke, John W.; Das, Subinoy

    2013-01-01

    Objective Chronic sinusitis is the most prevalent chronic disease in the United States in adults aged 18 to 44 years, with approximately 250,000 operations performed annually. Although often successful, sinus surgery fails in greater than 15% of patients. Adhesion formation is a common complication and cause for subsequent revision surgery. Here, the authors evaluate a sprayable chitosan/starch-based sinus sealant and demonstrate its ability to reduce adhesion formation both in vitro and in 2 animal models. Study Design Randomized, controlled, animal trials. Setting Academic medical center (fibroblast experiments) and animal laboratories (sheep and rabbit studies). Subjects and Methods This sinus sealant was applied to human cultured fibroblasts obtained from surgically removed polyps to examine its ability to inhibit fibroblast migration and proliferation. The sinus sealant was applied to New Zealand White rabbits (n = 20) in an established cecal-sidewall abrasion model and to sheep (n = 10) in a sinus surgical adhesion model to examine its ability to reduce adhesion formation. Results This sinus sealant inhibited migration and proliferation of human cultured fibroblasts and reduced the total adhesion score from 4.9 to 0.3 for a total reduction of 94% (95th percentile confidence interval [CI], 78%, 100%; P < .001) in a well-established rabbit cecal-sidewall model commonly used for adhesion testing. Moreover, this sealant reduced adhesion formation from 80% to 10% for a total reduction of 70% (95th percentile CI, 57%, 93%; P = .003) in a sheep sinus adhesion surgical model. Conclusion This chitosan-based sealant demonstrates promise for reducing adhesion formation in sinus surgery. PMID:22492298

  7. Effect of intracameral injection of fibrin tissue sealant on the rabbit anterior segment

    PubMed Central

    Chew, Annabel C.Y.; Tan, Donald T.H.; Poh, Rebekah; HM, Htoon; Beuerman, Roger W.

    2010-01-01

    Purpose To investigate the effect of intracameral injection of fibrin tissue sealant on the anterior segment structures in a rabbit model. Methods One eye of 10 rabbits received an intracameral injection of fibrin tissue sealant with a thrombin concentration of 500 IU (TISSEEL), and the fellow eye received an intracameral injection of balanced salt solution as a control. The rabbits were followed up with serial slit-lamp examinations, photography, high resolution anterior segment optical coherence tomography scans with pachymetry measurement, and intraocular pressure (IOP) monitoring until complete dissolution of the fibrin sealant. Corneal endothelial cell viability was evaluated using live/dead cell assays. Apoptosis of the cornea and trabecular meshwork were evaluated using TUNEL assays. Ultra-structural examinations of the cornea and trabecular meshwork were performed using electron microscopy. Histology of the trabecular meshwork and iris were analyzed using light microscopy. Results The quantity of the intracameral fibrin sealant was shown to be significantly correlated with increased IOP and pachymetry post-operatively. Complete dissolution of the fibrin sealant occurred between 15 and 30 days. Live/dead cell assays showed no decrease in viability of the corneal endothelium, and TUNEL assays showed no increase in apoptosis of the corneal epithelium, stroma, endothelium, or trabecular meshwork in the eyes with the fibrin sealant. Light and electron microscopy of the anterior segment structures were unremarkable. Conclusion The intracameral use of fibrin glue was associated with a transient increase in IOP and pachymetry. However, there was no evidence of toxicity or structural damage to the corneal endothelium, trabecular meshwork, or iris. PMID:20596250

  8. Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study.

    PubMed

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S; Jorgensen, L N; Rosenberg, J

    2013-08-01

    Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown. We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up. Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009). Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.

  9. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    PubMed

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  10. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak

    PubMed Central

    Erşen, Ezel; Demirkaya, Ahmet; Kara, H. Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-01-01

    Background Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. Methods A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Results Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Conclusions Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery. PMID:29221263

  11. Effect of dry period length on the effect of an intramammary teat sealant on the risk of mastitis in cattle treated with antibiotics at drying off.

    PubMed

    Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E

    2014-07-01

    The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole herd antibiotic treatment at drying off. Teat sealant reduced risk of clinical mastitis in cattle with dry periods substantially longer than 100 days, and there was no evidence that this effect changed as dry period length increased.

  12. Experimental Investigation of Bio-Sealants Used for Pavement Preservation and Development of a New Strength Test for Asphalt Binders at Low Temperature

    NASA Astrophysics Data System (ADS)

    Ghosh, Debaroti

    Surface treatment using sealants as a mean of pavement preservation is an important tool for cost-effectively extending service life of pavement. Sealants have become an important tool for cost-effectively extending the service life pavements. Due to the combined negative effects of asphalt aging and thermal cracking, it is always more challenging to choose an appropriate preservation technique for pavements built in cold-regions. Asphalt aging and thermal cracking negatively affect pavements built in cold climates. Therefore, it is important to evaluate the effects of sealants in laboratory conditions before application in the field to ensure effective performance. However, preservation activities cannot effectively address major distresses, such as low-temperature cracking, that can occur when the pavement was built from the very beginning with less durable materials. Therefore, an essential requirement to mitigate low-temperature cracking of pavements for asphalt materials used in the construction of pavement built in cold- regions is ensuring proper fracture properties of the asphalt materials used in construction. This study has two parts. In the first part, a laboratory evaluation of the effects of adding bio-sealants to both asphalt binder and mixture is performed. The goal is to obtain relevant properties of treated asphalt materials to understand the mechanism by which sealants improve pavement performance. For asphalt binders, a dynamic shear rheometer and a bending beam rheometer were used to obtain rheological properties of treated and untreated asphalt binders. For asphalt mixtures, field cores from both untreated and treated sections were collected and thin beam specimens were prepared from the cores to compare the creep and strength properties of the field-treated and laboratory-treated mixture. It is observed that the oil-based sealants have a significant softening effect on the control binder compared to the water-based sealant and traditional emulsion. Oil-based sealants increased rutting and fatigue potential of the binder and helped the low-temperature cracking resistance. For asphalt mixtures, different trends are observed for the field samples compared to the laboratory prepared samples. Similar to binder results, significant differences are observed between the asphalt mixtures treated with oil-based and water-based sealants, respectively. Additional analyses were performed to better understand the sealant effects. Fourier transform infrared spectroscopy (FTIR) analysis showed that the sealant products could not be detected in mixture samples collected from the surface of the treated section. Semi-empirical Hirsch model was able to predict asphalt mixture creep stiffness from binder stiffness. The results of a distress survey of the test sections correlated well with the laboratory findings. In the second part, a news binder strength testing method is proposed with the goal to provide an effective tool for selecting asphalt binders that are crack resistant. A modified Bending Beam Rheometer (BBR) is used to perform three-point bending strength tests, at constant loading rate, on asphalt binder beams at low temperature. Based on the results, a protocol for selecting the most crack resistant material from binders with similar rheological properties is proposed.

  13. Packaging of microwave integrated circuits operating beyond 100 GHz

    NASA Technical Reports Server (NTRS)

    Samoska, L.; Daniel, E.; Sokolov, V.; Sommerfeldt, S.; Bublitz, J.; Olson, K.; Gilbert, B.; Chow, D.

    2002-01-01

    Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.

  14. Biodegradable-Polymer-Blend-Based Surgical Sealant with Body-Temperature-Mediated Adhesion.

    PubMed

    Behrens, Adam M; Lee, Nora G; Casey, Brendan J; Srinivasan, Priya; Sikorski, Michael J; Daristotle, John L; Sandler, Anthony D; Kofinas, Peter

    2015-12-22

    The development of practical and efficient surgical sealants has the propensity to improve operational outcomes. A biodegradable polymer blend is fabricated as a nonwoven fiber mat in situ. After direct deposition onto the tissue of interest, the material transitions from a fiber mat to a film. This transition promotes polymer-substrate interfacial interactions leading to improved adhesion and surgical sealant performance. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Interactions between F-111 Fuselage Fuel Tank Sealants. Part I. Characterisation of Polyester Sealants and their Hydrolytic Degradation Products,

    DTIC Science & Technology

    1983-12-01

    maleic acid , adipic acid , azelaic acid and suberic acid . To ensure complete esterification during the exhaustive degradation reactions, an...spectroscopic techniques. Major components were shown to be sebacic acid and neopentyl glycol. The most significant difference between the two polyester...and acid equivalent weights of the prepolymers, their hydrolysis products and hydrolysed cured sealants were determined to assess extent of degradation

  16. Fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery.

    PubMed

    Cheng, Yao; Ye, Mingxin; Xiong, Xianze; Peng, Su; Wu, Hong Mei; Cheng, Nansheng; Gong, Jianping

    2016-02-15

    Postoperative pancreatic fistula is one of the most frequent and potentially life-threatening complications following pancreatic resections. Fibrin sealants are introduced to reduce postoperative pancreatic fistula by some surgeons. However, the use of fibrin sealants during pancreatic surgery is controversial. To assess the safety, effectiveness, and potential adverse effects of fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery. We searched The Cochrane Library (2015, Issue 7), MEDLINE (1946 to 26 August 2015), EMBASE (1980 to 26 August 2015), Science Citation Index Expanded (1900 to 26 August 2015), and Chinese Biomedical Literature Database (CBM) (1978 to 26 August 2015). We included all randomized controlled trials that compared fibrin sealant group (fibrin glue or fibrin sealant patch) versus control group (no fibrin sealant or placebo) in people undergoing pancreatic surgery. Two review authors independently identified the trials for inclusion, collected the data, and assessed the risk of bias. We performed the meta-analyses using Review Manager 5. We calculated the risk ratio (RR) for dichotomous outcomes (or a Peto odds ratio for very rare outcomes), and the mean difference (MD) for continuous outcomes with 95% confidence intervals (CI). We included nine trials involving 1095 participants who were randomized to the fibrin sealant group (N = 550) and the control group (N = 545) after pancreatic surgery. All of the trials were at high risk of bias. There was no evidence of differences in overall postoperative pancreatic fistula (fibrin sealant 29.6%; control 31.0%; RR 0.93, 95% CI 0.71 to 1.21; P = 0.58; nine studies; low-quality evidence), postoperative mortality (3.1% versus 2.1%; Peto OR 1.29, 95% CI 0.59 to 2.82; P = 0.53; eight studies; very low-quality evidence), overall postoperative morbidity (29.6% versus 28.9%; RR 1.04, 95% CI 0.82 to 1.32; P = 0.77; five studies), reoperation rate (8.7% versus 10.7%; RR 0.80, 95% CI 0.53 to 1.21; P = 0.29; five studies), or length of hospital stay (12.9 days versus 13.1 days; MD -0.73 days, 95% CI -2.20 to 0.74; P = 0.331; six studies) between the groups. The proportion of postoperative pancreatic fistula that was clinically significant was not mentioned in most trials. On inclusion of trials that clearly distinguished clinically significant fistulas, there was inadequate evidence to establish the effect of fibrin sealants on clinically significant postoperative pancreatic fistula (9.4% versus 13.4%; RR 0.72, 95% CI 0.42 to 1.21; P = 0.21; three studies). Quality of life and cost effectiveness were not reported in any of the trials. Based on the current available evidence, fibrin sealants do not seem to prevent postoperative pancreatic fistula in people undergoing pancreatic surgery.

  17. Enamel Surface with Pit and Fissure Sealant Containing 45S5 Bioactive Glass.

    PubMed

    Yang, S-Y; Kwon, J-S; Kim, K-N; Kim, K-M

    2016-05-01

    Enamel demineralization adjacent to pit and fissure sealants leads to the formation of marginal caries, which can necessitate the replacement of existing sealants. Dental materials with bioactive glass, which releases ions that inhibit dental caries, have been studied. The purpose of this study was to evaluate the enamel surface adjacent to sealants containing 45S5 bioactive glass (BAG) under simulated microleakage between the material and the tooth in a cariogenic environment. Sealants containing 45S5BAG filler were prepared as follows: 0% 45S5BAG + 50.0% glass (BAG0 group), 12.5% 45S5BAG + 37.5% glass (BAG12.5 group), 25.0% 45S5BAG + 25.0% glass (BAG25.0 group), 37.5% 45S5BAG + 12.5% glass (BAG37.5 group), and 50.0% 45S5BAG + 0% glass (BAG50.0 group). A cured sealant disk was placed over a flat bovine enamel disk, separated by a 60-µm gap, and immersed in lactic acid solution (pH 4.0) at 37 °C for 15, 30, and 45 d. After the storage period, each enamel disk was separated from the cured sealant disk, and the enamel surface was examined with optical 3-dimensional surface profilometer, microhardness tester, and scanning electron microscopy. The results showed a significant increase in roughness and a decrease in microhardness of the enamel surface as the proportion of 45S5BAG decreased (P< 0.05). In the scanning electron microscopy images, enamel surfaces with BAG50.0 showed a smooth surface, similar to those in the control group with distilled water, even after prolonged acid storage. Additionally, an etched pattern was observed on the surface of the demineralized enamel with a decreasing proportion of 45S5BAG. Increasing the 45S5BAG filler contents of the sealants had a significant impact in preventing the demineralization of the enamel surface within microgaps between the material and the tooth when exposed to a cariogenic environment. Therefore, despite some marginal leakage, these novel sealants may be effective preventive dental materials for inhibiting secondary caries at the margins. © International & American Associations for Dental Research 2016.

  18. Method of fabricating a microelectronic device package with an integral window

    DOEpatents

    Peterson, Kenneth A.; Watson, Robert D.

    2003-01-01

    A method of fabricating a microelectronic device package with an integral window for providing optical access through an aperture in the package. The package is made of a multilayered insulating material, e.g., a low-temperature cofired ceramic (LTCC) or high-temperature cofired ceramic (HTCC). The window is inserted in-between personalized layers of ceramic green tape during stackup and registration. Then, during baking and firing, the integral window is simultaneously bonded to the sintered ceramic layers of the densified package. Next, the microelectronic device is flip-chip bonded to cofired thick-film metallized traces on the package, where the light-sensitive side is optically accessible through the window. Finally, a cover lid is attached to the opposite side of the package. The result is a compact, low-profile package, flip-chip bonded, hermetically-sealed package having an integral window.

  19. Efficacy of a new sealant to prevent white spot lesions during fixed orthodontic treatment : A 12-month, single-center, randomized controlled clinical trial.

    PubMed

    Hammad, Shaza M; Knösel, Michael

    2016-11-01

    White spot lesions (WSLs) are an undesirable side effect of fixed orthodontic appliance therapy and are reported to occur in 2-96 % of orthodontic patients. In this study, the efficacy of a new sealant to prevent WSLs during fixed orthodontic treatment was compared to a control group that did not receive sealant. For this 2-arm parallel-group randomized trial, 50 subjects aged 12-18 years (mean age 14.57 ± 2.04 years) were recruited from the orthodontics department at Mansoura University, Egypt. Eligibility criteria were no restorations, no active WSLs or caries, and adequate oral hygiene. Subjects were randomized in a 1:1 ratio to one of the two arms prior to undergoing fixed orthodontic treatment, namely a single application of SeLECT Defense™ sealant during the bracketing appointment or no sealant (control arm). Instructions and dentifrices for local home fluoridation regimen were identical in both groups. Oral hygiene was assessed using the Approximal Plaque Index (API) at specified time intervals. Dental photographs were taken for blinded WSLs assessment; inter- and intra-operator error were also calculated. Categorical data were tested using the χ 2 test, and a logistic regression model was adopted to detect associations between decalcification (WSLs), sealant application, and oral hygiene status. Only excellent or good oral hygiene were independent prognostic factors for preventing severe WSLs (p = 0.035). No significant effect on caries incidence was observed for the sealant. In combination with adequate oral hygiene SeLECT Defense™ helps to reduced the frequency of WSLs. However, the sealat showed no significant effect as sole preventive strategy.

  20. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    DTIC Science & Technology

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  1. Overview of CO2 Leakage Problems and Sealants for CO2 Leakage Remediation

    NASA Astrophysics Data System (ADS)

    Peng, Shudai

    Excessive Carbon Dioxide (CO2) emission has become a serious issue and caused lots of environmental problems. Carbon Capture and Storage (CCS) program has been developed to reduce the CO2 content in the atmosphere. CO2 storage has been targeted mainly on depleted oil or gas reservoirs and deep saline aquifers. However, leakage could occur through wellbores, cap rocks, formation faults, and fractures during and after CO2 injection. To minimize the risk, different types of sealants have been investigated to prevent CO2 leaks. The aim of this thesis is to provide a comprehensive review of the materials which could be used as CO2 sealants. Based on the difference of materials components, this research has classified the sealants into seven types, including cements, geopolymers, foams, gel systems, resin systems, biofilm barriers, and nanoparticles. For each type of sealants, its chemical components, physical properties, stabilities, impact factors, applied environments, advantages and limitations were summarized. The most commonly used sealant for CO2 leakage control from wellbore is still cement, and the aluminate-calcium based cement has the best properties. It is very challenging to seal the fractures and faults, far from wellbore due to the difficulty to deliver plugging materials into the in-depth of a reservoir. The thermo-stability is also a great challenge for most materials and should be evaluated under supercritical CO2 condition.

  2. Comparison between self-assembling peptide nanofiber scaffold (SAPNS) and fibrin sealant in neurosurgical hemostasis.

    PubMed

    Xu, Fei-Fan; Wang, Yue-Chun; Sun, Stella; Ho, Amy S W; Lee, Derek; Kiang, Karrie M Y; Zhang, Xiao-Qin; Lui, Wai-Man; Liu, Bai-Yun; Wu, Wu-Tian; Leung, Gilberto K K

    2015-10-01

    RADA16-I is a synthetic type I self-assembling peptide nanofiber scaffold (SAPNS) which may serve as a novel biocompatible hemostatic agent. Its application in neurosurgical hemostasis, however, has not been explored. Although RADA16-I is nontoxic and nonimmunogenic, its intrinsic acidity may potentially provoke inflammation in the surgically injured brain. We conducted an animal study to compare RADA16-I with fibrin sealant, a commonly used agent, with the hypothesis that the former would be a comparable alternative. Using a standardized surgical brain injury model, 30 Sprague-Dawley rats were randomized into three treatment groups: RADA16-I, fibrin sealant or gelatin sponge (control). Animals were sacrificed on day 3 and 42. Astrocytic and microglial infiltrations within the cerebral parenchyma adjacent to the operative site were significantly lower in the RADA16-I and fibrin sealant groups than control. RADA16-I did not cause more cellular inflammatory response despite its acidity when compared with fibrin sealant. Immunohistochemical studies showed infiltration by astrocytes and microglia into the fibrin sealant and RADA16-I grafts, suggesting their potential uses as tissue scaffolds. RADA16-I is a promising candidate for further translational and clinical studies that focus on its applications as a safe and effective hemostat, proregenerative nanofiber scaffold as well as drug and cell carrier. © 2015 Wiley Periodicals, Inc.

  3. A new fibrin sealant as a three-dimensional scaffold candidate for mesenchymal stem cells

    PubMed Central

    2014-01-01

    Introduction The optimization of an organic scaffold for specific types of applications and cells is vital to successful tissue engineering. In this study, we investigated the effects of a new fibrin sealant derived from snake venom as a scaffold for mesenchymal stem cells, to demonstrate the ability of cells to affect and detect the biological microenvironment. Methods The characterization of CD34, CD44 and CD90 expression on mesenchymal stem cells was performed by flow cytometry. In vitro growth and cell viability were evaluated by light and electron microscopy. Differentiation into osteogenic, adipogenic and chondrogenic lineages was induced. Results The fibrin sealant did not affect cell adhesion, proliferation or differentiation and allowed the adherence and growth of mesenchymal stem cells on its surface. Hoechst 33342 and propidium iodide staining demonstrated the viability of mesenchymal stem cells in contact with the fibrin sealant and the ability of the biomaterial to maintain cell survival. Conclusions The new fibrin sealant is a three-dimensional scaffolding candidate that is capable of maintaining cell survival without interfering with differentiation, and might also be useful in drug delivery. Fibrin sealant has a low production cost, does not transmit infectious diseases from human blood and has properties of a suitable scaffold for stem cells because it permits the preparation of differentiated scaffolds that are suitable for every need. PMID:24916098

  4. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.

    PubMed

    Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L

    2010-05-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.

  5. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases.

    PubMed

    Siman, Homayoun; Techy, Fernando

    2016-02-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.

  6. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases

    PubMed Central

    Siman, Homayoun; Techy, Fernando

    2015-01-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT. PMID:26835216

  7. Testing Cessation Messages for Cigarette Package Inserts: Findings from a Best/Worst Discrete Choice Experiment

    PubMed Central

    Thrasher, James F.; Davis, Rachel E.; Popova, Lucy; Cho, Yoo Jin; Salloum, Ramzi G.; Louviere, Jordan; Hammond, David

    2018-01-01

    This study assessed smokers’ responses to different smoking cessation topics and imagery for cigarette package inserts. Adult smokers from Canada (n = 1000) participated in three discrete choice experiments (DCEs): DCE 1 assessed five cessation benefit topics and five imagery types; DCE 2 assessed five messages with tips to improve cessation success and five imagery types; DCE 3 assessed four reproductive health benefits of cessation topics and four imagery types. In each DCE, participants evaluated four or five sets of four inserts, selecting the most and least motivating (DCEs 1 & 3) or helpful (DCE 2) for quitting. Linear mixed models regressed choices on insert and smoker characteristics. For DCE 1, the most motivating messages involved novel disease topics and imagery of younger women. For DCE 2, topics of social support, stress reduction and nicotine replacement therapy were selected as most helpful, with no differences by imagery type. For DCE 3, imagery influenced choices more than topic, with imagery of a family or a mom and baby selected as most motivating. Statistically significant interactions for all three experiments indicated that the influence of imagery type on choices depended on the message topic. Messages to promote smoking cessation through cigarette pack inserts should consider specific combinations of message topic and imagery. PMID:29415523

  8. Coal-tar-based pavement sealants—a potent source of PAHs

    USGS Publications Warehouse

    Mahler, Barbara J.; Van Metre, Peter C.

    2017-01-01

    P avement sealants are applied to the asphalt pavement of many parking lots, driveways, and even playgrounds in North America (Figure 1), where, when first applied, they render the pavement glossy black and looking like new. Sealant products used commercially in the central, eastern, and northern United States typically are coal-tarbased, whereas those used in the western United States typically are asphalt-based. Although the products look similar, they are chemically different. Coal-tarbased pavement sealants typically are 25-35 percent (by weight) coal tar or coal-tar pitch, materials that are known human carcinogens and that contain high concentrations of polycyclic aromatic hydrocarbons (PAHs) and related chemicals (unless otherwise noted, all Figure 1. Pavement sealant is commonly used to seal parking lots, playgrounds, and driveways throughout the United States. Sealants used in the central, northern, eastern, and southern United States typically contain coal tar or coal-tar pitch, both of which are known human carcinogens. Photos by the U.S. Geological Survey. data in this article are from Mahler et al. 2012 and references therein).

  9. Estrogenicity of resin-based composites and sealants used in dentistry.

    PubMed Central

    Olea, N; Pulgar, R; Pérez, P; Olea-Serrano, F; Rivas, A; Novillo-Fertrell, A; Pedraza, V; Soto, A M; Sonnenschein, C

    1996-01-01

    We tested some resin-based composites used in dentistry for their estrogenic activity. A sealant based on bisphenol-A diglycidylether methacrylate (bis-GMA) increased cell yields, progesterone receptor expression, and pS2 secretion in human estrogen-target, serum-sensitive MCF7 breast cancer cells. Estrogenicity was due to bisphenol-A and bisphenol-A dimethacrylate, monomers found in the base paste of the dental sealant and identified by mass spectrometry. Samples of saliva from 18 subjects treated with 50 mg of a bis-GMA-based sealant applied on their molars were collected 1 hr before and after treatment. Bisphenol-A (range 90-931 micrograms) was identified only in saliva collected during a 1-hr period after treatment. The use of bis-GMA-based resins in dentistry, and particularly the use of sealants in children, appears to contribute to human exposure to xenoestrogens. Images Figure 1. A Figure 1. B Figure 2. Figure 3. A Figure 3. B Figure 4. A Figure 4. B Figure 5. A Figure 5. B Figure 6. A Figure 6. B Figure 7. A Figure 7. B Figure 8. Figure 9. Figure 10. PMID:8919768

  10. Minimally Invasive Pterygium Surgery: Sutureless Excision with Amniotic Membrane and Hydrogel Sealant.

    PubMed

    Bondalapati, Sailaja; Ambati, Balamurali

    2016-01-01

    To describe a novel technique for sutureless pterygium surgery using ReSure(®) tissue sealant. In this retrospective observational case series, we describe a modified procedure for pterygium excision followed by amniotic membrane transplant (AMT) adhered to the corneal and conjunctival defects using ReSure tissue sealant. Nine eyes of seven patients (age range: 28-80 years, 4 females and 3 males) underwent pterygium removal with AMT followed by adherence of tissue to the conjunctival edges with ReSure. No issues with transplant dislocation or failure and no intra- or postoperative complications were noted. No recurrences were noted during the follow-up period. ReSure may be considered as a potential sealant to adhere AMT to defective corneal and conjunctival tissues in sutureless pterygium surgery.

  11. A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.

    PubMed

    Holman, Benjamin; Kerry, Joseph P; Hopkins, David L

    2017-10-31

    Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Fate and Transport of Chemical Warfare Agents VX and HD ...

    EPA Pesticide Factsheets

    Report The intent of this investigation was to study the fate and transport of CWA applied to painted/sealed materials including the potential partitioning of CWA into permeable paints/sealants and subsequently into underlying porous materials. Based on the results obtained from this investigation, VX and sulfur mustard (HD) have the ability to permeate into paints and sealants, including in some cases the underlying porous materials. It is likely that other permeable materials besides paints and sealants may also show similar behavior.

  13. Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Leeper, William R., E-mail: rob.leeper@jhmi.edu; Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu

    2015-08-15

    Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    "rsed" is an R package that contains tools for stream editing: manipulating text files by making insertions, replacements, deletions, substitutions, or commenting. It hails from the powerful Unix command, "sed". While the "rsed" package is not nearly as powerful as "see", it is much simpler to use. R programmers often write scripts that may require simple manipulation of text files. "rsed" addresses that need.

  15. Microstructure-Evolution and Reliability Assessment Tool for Lead-Free Component Insertion in Army Electronics

    DTIC Science & Technology

    2008-10-01

    provide adequate means for thermal heat dissipation and cooling. Thus electronic packaging has four main functions [1]: • Signal distribution which... dissipation , involving structural and materials consideration. • Mechanical, chemical and electromagnetic protection of components and... nature when compared to phenomenological models. Microelectronic packaging industry spends typically several months building and reliability

  16. Fibrin sealant use for minimising peri-operative allogeneic blood transfusion

    PubMed Central

    Carless, Paul A; Henry, David A; Anthony, Danielle M

    2014-01-01

    Background Fibrin sealants (also referred to as biological glue or fibrin tissue adhesives) have gained increasing popularity as interventions to improve peri-operative (intra- and post-operative) haemostasis and diminish the need for allogeneic red cell transfusion (blood from an unrelated donor). Objectives To examine the efficacy of fibrin sealants in reducing peri-operative blood loss and allogeneic red blood cell (RBC) transfusion. Search methods We identified studies by searching CENTRAL (The Cochrane Library 2007, Issue 3), MEDLINE (1950 to 2008), EMBASE (1980 to 2008), manufacturer web sites (to March 2008), and bibliographies of relevant published articles. Selection criteria Controlled trials in which adult patients scheduled for elective surgery were randomised to fibrin sealant treatment or to a control group which did not receive fibrin sealant treatment. Trials were eligible if they reported data on the number of patients exposed to allogeneic red cell transfusion, the volume of blood transfused, or blood loss (assessed objectively). Data collection and analysis The primary outcomes measured were the: number of patients exposed to allogeneic red cells, amount of blood transfused, and blood loss. Other outcomes measured were: re-operation due to bleeding, infection, mortality, thrombotic events, and length of hospital stay. Treatment effects were pooled using a random-effects model. Main results Eighteen trials that included a total of 1406 patients reported data on peri-operative exposure to allogeneic RBC transfusion. Fibrin sealant treatment, on average, reduced the rate of exposure to allogeneic RBC transfusion by a relative 37% (relative risk (RR) 0.63, 95% confidence interval (CI) 0.45 to 0.88) and 7% in absolute terms (95% CI 2% to 13%). Fourteen trials, including a total of 853 patients, provided data for post-operative blood loss. In aggregate, fibrin sealant treatment reduced blood loss on average by around 161 ml per patient (95% CI 98.25 to 224.53 ml). In the context of orthopaedic surgery, fibrin sealant treatment reduced post-operative blood loss on average by around 223 ml per patient (95% CI 119.85 to 325.18 ml) and reduced the risk of exposure to allogeneic RBC transfusion by 32% (RR 0.68, 95% CI 0.51 to 0.89). Fibrin sealant treatment was not associated with an increased risk of wound infection (RR 0.61, 95% CI 0.24 to 1.58), any infection (RR 0.93, 95% CI 0.44 to 1.94), haematoma formation (RR 0.46, 95% CI 0.18 to 1.18), or death (RR 0.85, 95% CI 0.38 to 1.89). Hospital length of stay was not reduced in patients treated with fibrin sealant (weighted mean difference (WMD) −0.21 days, 95% CI −0.42 to 0.01 days). Authors’ conclusions Overall, the results suggest that fibrin sealants are efficacious in reducing both post-operative blood loss and peri-operative exposure to allogeneic RBC transfusion. Although treatment-effect heterogeneity was observed for these primary efficacy outcomes, heterogeneity was generally in terms of the size of effect rather than the direction of effect. Fibrin sealants appeared to demonstrate their greatest beneficial effects in the context of orthopaedic surgery, where blood loss is often substantial. Trials not involving orthopaedic surgery generally showed a trend toward decreased post-operative blood loss but the observed reductions were not clinically significant. The majority of trials included in this review were small, which raises concerns about the potential effects of publication bias. Funnel plot assessment indicates that there is some evidence of publication bias in the form of a missing population of small negative trials. We believe that large, methodologically rigorous, randomised controlled trials of fibrin sealants are needed. PMID:12804501

  17. Do package inserts reflect symptoms experienced in practice?: assessment using an automated phone pharmacovigilance system with varenicline and zolpidem in a primary care setting.

    PubMed

    Haas, Jennifer S; Amato, Mary; Marinacci, Lucas; Orav, E John; Schiff, Gordon D; Bates, David W

    2012-08-01

    While the US FDA maintains a voluntary reporting system, postmarketing adverse drug events (ADEs) are underreported, and this case report-based system does not allow accurate determination of incidence. The aim of the study was to assess the usefulness of an automated phone pharmacovigilance system for ambulatory patients by comparing systematically collected, patient-reported symptoms to reflect possible ADEs with those reported on the package inserts of two drugs with postmarketing safety concerns, varenicline and zolpidem. English-speaking adults who received a prescription for zolpidem (n = 370) or varenicline (n = 107) from a primary care physician at one of 11 participating clinics, and who participated in the pharmacovigilance system during 2008-2010, were included in the study. Patients were called approximately 4 weeks following their visit and asked to complete a standard script that asked about adherence and pre-specified symptoms. The main outcome measures were elicited rates of pre-specified symptoms or possible ADEs. Compared with the package insert, patients taking zolpidem were significantly (p < 0.001) more likely to report fatigue (9.0% vs 1.0%), itching (4.5% vs 1.0%) and muscle aches (5.6% vs 1.0%). Elicited rates of depression and hallucination were similar to those reported in the package insert. Patients taking varenicline were significantly more likely to report confusion (1.7% vs 0.1%), depression (3.4% vs 0.1%), fatigue (6.0% vs 1.0%), hallucinations (1.7% vs 0.1%), muscle aches (6.0% vs 1.0%) and sexual dysfunction (4.3% vs 0.1%). Automated phone pharmacovigilance can provide estimates of possible ADEs in clinical practice. In the case of varenicline, these data support some of the safety concerns that have come to light postmarketing, while others such as depression and hallucination related to zolpidem were not detected. These data highlight the potential value of, and innovative ways of collecting, information about possible ADEs directly from patients.

  18. Technical Note: Computer-Manufactured Inserts for Prosthetic Sockets

    PubMed Central

    Sanders, Joan E.; McLean, Jake B.; Cagle, John C.; Gardner, David W.; Allyn, Katheryn J.

    2016-01-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant’s test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11 mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03 mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. PMID:27212209

  19. Joint sealant materials for concrete pavement repairs.

    DOT National Transportation Integrated Search

    1991-01-01

    This report on joint sealant materials for concrete pavement repairs is based on conversations with specialists from several states, the Federal Highway Administration, the Portland Cement Association, and the American Concrete Pavement Association, ...

  20. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  1. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  2. Knowledge, value, opinion and practice about usage of pit and fissure sealant among dental professionals in Chennai, Tamil Nadu, India.

    PubMed

    Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil

    2015-12-01

    A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for <5 years, 35.4% for 5-10 years, and 13.5% for >15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.

  3. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    PubMed

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  4. Evaluation of the remineralization potential of amorphous calcium phosphate and fluoride containing pit and fissure sealants using scanning electron microscopy.

    PubMed

    Choudhary, Prashant; Tandon, Shobha; Ganesh, M; Mehra, Anshul

    2012-01-01

    To evaluate the remineralization potential of Amorphous Calcium Phosphate (ACP) and Fluoride containing pit and Fissure Sealants using Scanning Electron Microscopy. Thirty maxillary first premolars were divided into three groups of ten each and were randomly selected for ACP containing (Aegis- Opaque White, Bosworth Co. Ltd.), Fluoride containing (Teethmate F1 Natural Clear, Kuraray Co. Ltd.), resin based (Concise- Opaque White, 3M ESPE Co. Ltd.) pit and fissure sealant applications. The Concise group served as a control. The teeth weresubjected to the pH-cycling regimen for a period of two weeks. After two weeks, the teeth were sectioned bucco-lingually into 4mm sections and were observed under Scanning Electron Microscope at 50X, 250X, 500X, 1000X and 1500X magnifications. The qualitative changes at the tooth surface and sealant interface were examined and presence of white zone at the interface was considered positive for remineralization. Both ACP containing (Aegis) and Fluoride containing (Teethmate F1) group showed white zone at the tooth surface-sealant interface. The resin based group (Concise) showed regular interface between the sealant and the tooth structure, but no clear cut white zone was observed. Both, Aegis and Teethmate F1 have the potential to remineralize. Release of Amorphous Calcium Phosphate molecules in Aegis group and formation of Fluoroapetite in Teethmate F1 group, were probably responsible for the remineralization.

  5. In vitro comparison of two widely used surgical sealants for treating alveolar air leak.

    PubMed

    Zhang, Ruoyu; Bures, Maximilian; Höffler, Klaus; Jonigk, Danny; Haverich, Axel; Krueger, Marcus

    2014-12-01

    Controversies surrounding the efficacy of sealants against alveolar air leak (AAL) are abundant in the literature. We sought to test the widely used sealants, TachoSil (Takeda Pharmaceutical Company Limited, Osaka, Japan) and BioGlue (CryoLife Europa Ltd., Surrey, United Kingdom) in an in vitro model. Materials and After creation of a focal superficial defect (40 × 25 mm) in swine lungs (n=40), AAL was assessed with increasing inspired tidal volume (TVi). Upon sealant application in a randomized order, AAL was assessed in the same way until sealant burst. At TVi =400, 500, 600, and 700 mL, BioGlue achieved sealing in 19, 19, 16, and 14 tests, while TachoSil sealed in 19, 14, 4, and no test, respectively. The maximally tolerated pressure of BioGlue was higher than TachoSil (40.3 ± 3.0 vs. 36.0 ± 4.9 cm H2O, p=0.003). Cohesive and adhesive failures were found in 10 and 1 tests of BioGlue, respectively, while all burst failures of TachoSil were adhesive. Concerning elasticity, TachoSil allowed more expansion of the covered defect than BioGlue (6.3 ± 3.9 vs. 1.4 ± 1.0 mm, p<0.001). The tested sealants demonstrated high sealing efficacy. While BioGlue was superior in resisting higher ventilation pressure, TachoSil possessed better elasticity. Georg Thieme Verlag KG Stuttgart · New York.

  6. Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery.

    PubMed

    Masket, Samuel; Hovanesian, John A; Levenson, Jeffrey; Tyson, Farrell; Flynn, William; Endl, Michael; Majmudar, Parag A; Modi, Satish; Chu, Ralph; Raizman, Michael B; Lane, Stephen S; Kim, Terry

    2014-12-01

    To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. Twenty-four ophthalmic clinical practices in the United States. Prospective randomized parallel-arm controlled multicenter subject-masked study. Healthy patients having uneventful clear corneal incision (CCI) cataract surgery were eligible for the study. Spontaneous and provoked fluid egress from wounds was evaluated at the time of surgery using a calibrated force gauge. Eyes with leakage were randomized to receive a hydrogel sealant (Resure) or a nylon suture at the main incision site. Incision leakage was reevaluated 1, 3, 7, and 28 days postoperatively. Of 500 eyes, 488 had leakage at the time of cataract surgery. The leak was spontaneous in 244 cases (48.8%), and 488 (97.6%) of all incisions leaked with 1.0 ounce or less of applied force. After randomization, 12 (4.1%) of 295 eyes in the sealant group and 60 (34.1%) of 176 eyes in the suture group had wound leakage with provocation (P<.0001). The overall incidence of adverse ocular events was statistically significantly lower in the sealant group than in the suture group (P<.05). In this study, 97.6% of CCIs leaked after cataract surgery. The hydrogel sealant was safe and effective and better than a suture for the intraoperative management of CCIs with leakage as seen on Seidel testing and for the prevention of postoperative fluid egress. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    PubMed

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  8. Clinical performance of a glass ionomer sealant protected with two different resin-based agents over a 2-year follow-up period.

    PubMed

    Ulusoy, A T; Tunc, E S; Bayrak, Ş

    2017-03-01

    To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.

  9. Design, fabrication, and implementation of thermally driven outdoor testing devices for building joint sealants.

    PubMed

    White, C C; Tan, K T; O'Brien, E P; Hunston, D L; Chin, J W; Williams, R S

    2011-02-01

    The paper describes the development, implementation, and testing of two thermally driven outdoor exposure instruments. These devices are unique in their ability to impose field generated thermally induced strain on sealant specimens while monitoring their resulting load and displacement. The instruments combine a fixed wood and steel supporting frame with a moving polyvinyl chloride frame, and employ differences in the coefficients of thermal expansion between the supporting frame and moving frame to induce strain on the sealant specimens. Two different kinds of instruments have been fabricated, "winter/tension" and "winter/compression" designs. In the winter/tension design, the thermally induced dimensional change is directly transferred to the specimens; while in the winter/compression design, the samples are loaded in an opposite direction with the dimensional change. Both designs are instrumented to monitor load and displacement and are built so that the strain on the specimen does not exceed ±25% over the range of temperatures expected in Gaithersburg, MD. Additionally, a weather station is colocated with the device to record environmental conditions in 1 min intervals. This combination of weather information with mechanical property data enables a direct link between environmental conditions and the corresponding sealant response. The reliability and effectiveness of these instruments are demonstrated with a typical sealant material. The results show that the instruments work according to the design criteria and provide a meaningful quantitative platform to monitor the mechanical response of sealant exposed to outdoor weathering.

  10. Efficacy of quilting sutures and fibrin sealant together for prevention of seroma in extended latissimus dorsi flap donor sites.

    PubMed

    Shin, In Soo; Lee, Dong Won; Lew, Dae Hyun

    2012-09-01

    The extended latissimus dorsi flap is important for breast reconstruction. Unfortunately, donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. Although using fibrin sealant in the donor site reduces the rate of seroma formation, donor site seroma remains a troublesome complication. The purpose of this study was to analyze the effectiveness of the combination of quilting sutures and fibrin sealant in the latissimus dorsi donor site for the prevention of seroma. Forty-six patients who underwent breast reconstruction with extended latissimus flap were enrolled in the study. The patients received either fibrin sealant (group 1, n=25) or a combination of fibrin sealant and quilting sutures (group 2, n=21) in the extended latissimus dorsi donor site. Outcome measures were obtained from the incidence, volume of postoperative seroma, total drainage amount, indwelling period of drainage, and duration of hospital stay. The incidence of seroma was 76% in group 1 and 42.9% in group 2 (P=0.022). We also found significant reductions in seroma volume (P=0.043), total drainage amount (P=0.002), indwelling period of drainage (P=0.01), and frequency of aspiration (P=0.043). The quilting sutures did not affect the rate of drainage, tube reinsertion, or hospital stay. The use of quilting sutures combined with fibrin sealant on the latissimus dorsi flap donor site is helpful for reducing the overall seroma volume, frequency of aspiration, and total drainage amount.

  11. Reading about over-the-counter medications.

    PubMed

    Nabors, Laura A; Lehmkuhl, Heather D; Parkins, Irina S; Drury, Anna M

    2004-01-01

    Many adolescents and young adults purchase and use over-the-counter (OTC) medications, and some may take these medications without reading about how to use them. Most do read package inserts and labels to learn about the medication, but studies examining what influences label reading for youth are needed. This study assessed factors related to label reading for young people, including demographic variables (gender, health status) and the types of information they were seeking about the medication. Eight hundred and seventy-six high school and college students participated, and most reported reading labels or package inserts to learn about medications. Participants experiencing pain were more likely to read labels, except for those experiencing headaches who reported being less likely to read labels. When reading labels, participants were interested in information about side effects, ingredients, dosage instructions, and symptoms treated by the medication. Future research should examine whether youth take medications as directed and what factors make labels and inserts easier to read and understand.

  12. Jig Aligns Shadow Mask On CCD

    NASA Technical Reports Server (NTRS)

    Matus, Carlos V.

    1989-01-01

    Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

  13. Construction Productivity Advancement Research (CPAR) Program: Improved Materials and Processes for Sealing and Resealing Joints in Portland Cement Concrete Pavements - Field Evaluation

    DTIC Science & Technology

    1993-10-01

    sealant was determined by noting the type and number of defects each sealant incurred. Figure 4 provides a sample evaluation sheet used dur- ing the field...was conducted by visually inspect- ing the mater~al for defects . If any defects were noted, the type of defect was described and the quant~ty of that... defect was measured. The quantity of the defect was dividted by the total quantity of sealant and the result reported as percent defect . Adhesion and

  14. Fibrin sealant for closure of mucosal penetration at the cardia during peroral endoscopic myotomy: A retrospective study at a single center

    PubMed Central

    Zhang, Wen-Gang; Linghu, En-Qiang; Li, Hui-Kai

    2017-01-01

    AIM To assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia during peroral endoscopic myotomy (POEM). METHODS Twenty-four patients who underwent POEM and experienced mucosal injury of the cardia during the procedure were retrospectively identified. Of the 24 patients, 21 had mucosal penetration and 3 had only slight mucosal damage without penetration. The 21 patients with mucosal penetration received fibrin sealant for closure at the site of penetration. Penetration-related characteristics, treatment, and recovery were reviewed for all 21 patients to assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia. Clinical data, including general characteristics, procedure-related parameters, Eckardt scores, lower esophageal sphincter pressures (LESP), and esophagogastroduodenoscopy (EGD) results, were analyzed to determine their influence on treatment success after mucosal penetration during POEM. RESULTS All 21 patients had a solitary mucosal penetration in the cardia (12 in esophageal region of the cardia, 9 in the stomach region of the cardia, and 1 in both the esophageal and stomach regions). Twelve had a hole-like penetration and 9 had a linear penetration. For those with a hole-like penetration, the mean size was 0.14 cm2 (0.02-0.32 cm2). For those with a linear penetration, the median size was 0.37 cm (0.10-1.00 cm). Closure of the mucosal penetration using fibrin sealant was performed successfully in all 21 patients (two patients required 5 mL fibrin sealant, and the remaining 19 patients required 2.5 mL). Two patients had a nasogastric tube placed for five days after POEM; the remaining 19 patients were kept fasting for 3 d. All 21 patients were discharged after a median of 5 d (range: 5-7 d) postoperatively. During a median 42 mo (range: 9-62 mo) follow-up, all 21 patients with a mucosal penetration successfully healed without the occurrence of infection, ulcer, or esophagitis. Furthermore, the median LESP decreased from 31.9 mmHg (range: 21.9-67.1 mmHg) preoperatively to 20.3 mmHg (range: 6.0-41.0 mmHg) postoperatively (P < 0.05). The median preoperative and postoperative Eckardt scores were 5.0 (range; 4-10) and 1.0 (range: 0-4), respectively (P < 0.05). Of the 21 patients with mucosal penetration, symptom remission, which is defined as a postoperative Eckardt score ≤ 3, was achieved in 20 patients (95.2%) indicating that mucosal penetration did not influence the success of POEM treatment if closed successfully using fibrin sealant. CONCLUSION Fibrin sealant is safe and effective for closure of mucosal penetration during POEM. Mucosal penetrations do not appear to influence the treatment success of POEM if closed successfully using fibrin sealant. Additional studies regarding the feasibility, efficacy, and safety of fibrin sealant for closure of larger mucosal penetrations is warranted. PMID:28321165

  15. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    PubMed

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  16. PAH volatilization following application of coal-tar-based pavement sealant

    USGS Publications Warehouse

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.

  17. Validation of hot-poured crack sealant performance-based guidelines.

    DOT National Transportation Integrated Search

    2017-06-01

    This report summarizes a comprehensive research effort to validate thresholds for performance-based guidelines and : grading system for hot-poured asphalt crack sealants. A series of performance tests were established in earlier research and : includ...

  18. Adhesion testing procedure for hot-poured crack sealants.

    DOT National Transportation Integrated Search

    2008-11-01

    Crack sealing is a common pavement maintenance treatment because it extends pavement service life significantly. : However, crack sealant often fails prematurely due to a loss of adhesion. Because current test methods are mostly : empirical and only ...

  19. Field manual for crack sealing in asphalt pavements.

    DOT National Transportation Integrated Search

    2006-01-01

    This field manual was developed as a product of research project 4061 Comparison of Hot Poured Crack Sealant to Emulsified Asphalt Crack Sealant conducted by The University of Texas at Austin Center for Transportation Research (CTR). Organizati...

  20. Development of new photopolymerizable dental sealants.

    PubMed

    Davidenko, N; Cohen, M E; Diaz, J M; Sastre, R

    1998-01-01

    This paper describes the results obtained in the optimization of the composition of dental sealants in relation to the nature and proportions of monomer mixtures and photoinitiating system employed. The quantification and variation of certain parameters which determine the quality of a dental sealant (such as viscosity and penetrating power, residual double bonds, solubility and absorption, volume shrinkage and certain specific mechanical properties) have resulted in the development of new formulations. The composition which has achieved the best results of all the above properties was that corresponding to the monomer mixture bis-GMA/tri(ethylene glycol) dimethacrylate (TEGDMA) 40/60 wt%, and the photoinitiating system camphorquinone (CQ) with co-initiators N,N,3,5-tetramethyaniline (TMA) or N,N-dimethyl-p-toluidine (DMPT) in the ratio 1:1. The final properties and characteristics of the obtained formulations are superior to those of commercial dental sealants currently in use.

  1. An in-vitro evaluation of mechanical and esthetic properties of orthodontic sealants

    PubMed Central

    Premaraj, Thyagaseely Sheela; Rohani, Nima; Covey, David; Premaraj, Sundaralingam; Hua, Yi; Watanabe, Hidehiko

    2014-01-01

    Objective: To evaluate mechanical and esthetic Properties of two commercially available orthodontic sealants: Opal®Seal (OS) and L.E.D. Pro Seal (PS). Materials and Methods: Discs of each sealant were prepared to test the following properties: Micro hardness, wear resistance and color stability. Samples were randomly selected after the wear test for SEM imaging to analyze surface morphology. Results: OS was significantly harder than PS (P < 0.001). PS was significantly more wear resistant than OS (P < 0.05). PS showed a greater ∆E*ab (increased staining) when placed in wine or coffee showing a significant difference (P < 0.05). SEM showed particle size, shape and distribution were different for PS and OS reflecting the pattern seen on wear surfaces. Conclusion: Both orthodontic sealants are beneficial for protecting enamel. However with better wear properties PS was superior in resisting mechanical stresses. OS was more color stable. PMID:25512729

  2. Application of a hydrogel ocular sealant to avoid recurrence of epithelial ingrowth after LASIK enhancement.

    PubMed

    Yesilirmak, Nilufer; Diakonis, Vasilios F; Battle, Juan F; Yoo, Sonia H

    2015-04-01

    To report a case of clinically significant epithelial ingrowth after LASIK that was successfully treated with a hydrogel ocular sealant in combination with flap lifting and scraping technique. Case report. A 56-year-old woman underwent LASIK and a LASIK enhancement procedure in 2002 and 2012, respectively. Six months after the enhancement, visually significant epithelial ingrowth developed in both of her eyes. The left eye was treated with flap lifting, scraping, and suturing, and the right eye was treated with a hydrogel ocular sealant in combination with flap lifting and scraping. No recurrence was evident during a 6-month follow-up period and visual acuity improved in both eyes. No adverse effects were noticed. Recurrent epithelial ingrowth may be successfully avoided with the intraoperative use of a hydrogel ocular sealant combined with flap lifting and scraping. This approach could be used as an alternative to LASIK flap suturing. Copyright 2015, SLACK Incorporated.

  3. Fibrin sealant: past, present, and future: a brief review.

    PubMed

    Spotnitz, William D

    2010-04-01

    Fibrin sealant is a two-component topical hemostat, sealant, and tissue adhesive consisting of fibrinogen and thrombin that has been used in the United States as a blood bank- or laboratory-derived product since the 1980s and has been commercially available since 1998. Initially, surgeons employed hospital-based materials because of the lack of availability of a commercially produced agent. At present, there are five U.S. Food and Drug Administration (FDA)-approved forms including products derived from pooled or autologous human plasma as well as bovine plasma. On-label indications include hemostasis, colonic sealing, and skin graft attachment. Recent clinical and experimental uses include tissue or mesh attachment, fistula closure, lymphatic sealing, adhesion prevention, drug delivery, and tissue engineering. The modern literature on fibrin sealant now exceeds 3000 articles and continues to expand. This brief review presents the history of this material, its present clinical use, and its future applications.

  4. Using PATIMDB to Create Bacterial Transposon Insertion Mutant Libraries

    PubMed Central

    Urbach, Jonathan M.; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M.

    2015-01-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software. PMID:19343706

  5. Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair.

    PubMed

    Schwab, R; Schumacher, O; Junge, K; Binnebösel, M; Klinge, U; Becker, H P; Schumpelick, V

    2008-03-01

    Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP. Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation. Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg. To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.

  6. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    PubMed

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  7. A Pre- and Post-Evaluation of Integrating Sustainability Curriculum by Inserting Okala Modules into an Interior Design Materials and Methods Course

    ERIC Educational Resources Information Center

    Schneiderman, Deborah; Freihoefer, Kara

    2012-01-01

    Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…

  8. Development of apparent viscosity test for hot-poured crack sealants.

    DOT National Transportation Integrated Search

    2008-11-01

    Current crack sealant specifications focuses on utilizing simple empirical tests such as penetration, : resilience, flow, and bonding to cement concrete briquettes (ASTM D3405) to measure the ability of the material : to resist cohesive and adhesion ...

  9. Evaluation of joint sealant materials : final report.

    DOT National Transportation Integrated Search

    1977-05-01

    In May, 1968, the Department's Research and Development Section initiated a project to evaluate joint sealants being marketed for use on roads and bridges. In the study, representatives of 31 companies installed 40 products primarily on one road and ...

  10. Reflectivity of crack sealant.

    DOT National Transportation Integrated Search

    2002-01-01

    Crack sealing is used in road maintenance but presents a problem when crack seal material visually pops out on the roadway, making it difficult to see lane stripes. This problem will increase as New Mexico increases its use of crack sealants. This su...

  11. Field evaluation of three joint sealants.

    DOT National Transportation Integrated Search

    1987-01-01

    The purpose of the study reported here was to evaluate the performance of three joint sealants compartmented (A) and closed cellular (B) preformed neoprene, and a two-component cold-mixed polysulfide (C)-- that were used in the interchanges for Inter...

  12. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    PubMed

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that sensory function improved when transgenic hESCs were used. The regeneration of sensory fibers indeed led to increased reflexes, upon stimulation of the paw ipsilateral to the lesion, as seen by von-Frey evaluation, which was supported by immunohistochemistry. Overall, the present data demonstrated that transgenic embryonic stem cells, engineered to overexpress FGF-2 in an inducible fashion, could be employed to support regeneration aiming at the recovery of both motor and sensory functions.

  13. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    PubMed Central

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs <12th grade = 43.3, p = 0.001), gender (male = 27.3 vs female = 19.6, p = 0.04), age (≤15 years = 27.1 vs <15 years = 18.5, p = 0.02), presence of fissure sealants (yes = 30.6 vs no = 13.5, p = 0.001) and experience of dental pain (no = 25.4 vs yes = 16.8, p = 0.02). When analyzing the prevalence of fissure sealants, we verified that 58.8% of adolescents had at least one fissure sealant applied. Significant statistical differences were found when analyzing the presence of fissure sealants related with parents´educational level (<9th grade, OR = 1.56 CI95% = 1.05–2.54), gender (female, OR = 1.86 CI95% = 1.19–2.98), experience of dental pain (yes, OR = 0.62 CI95% = 0.39–0.97) and presence of dental caries (yes, OR = 0.35 CI95% = 0.19–0.65). Conclusions The moderate level of caries prevalence reveals the need of improvement of primary prevention interventions among Portuguese adolescents. The establishment of a more targeted preventive program with better and more effective oral health education is essential, having into account socio-demographic aspects. PMID:25803849

  14. Mental models in risk assessment: informing people about drugs.

    PubMed

    Jungermann, H; Schütz, H; Thüring, M

    1988-03-01

    One way to communicate about the risks of drugs is through the use of package inserts. The problems associated with this medium of informing patients have been investigated by several researchers who found that people require information about drugs they are using, including extensive risk information, and that they are willing to take this information into account in their usage of drugs. But empirical results also show that people easily misinterpret the information given. A conceptual framework is proposed that might be used for better understanding the cognitive processes involved in such a type of risk assessment and communication. It is based on the idea that people develop, through experience, a mental model of how a drug works, which effects it might produce, that contraindications have to be considered, etc. This mental model is "run" when a specific package insert has been read and a specific question arises such as, for example, whether certain symptoms can be explained as normal or whether they require special attention and action. We argue that the mental model approach offers a useful perspective for examining how people understand package inserts, and consequently for improving their content and design. The approach promises to be equally useful for other aspects of risk analysis that are dependent upon human judgment and decision making, e.g., threat diagnosis and human reliability analysis.

  15. Technical note: Computer-manufactured inserts for prosthetic sockets.

    PubMed

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. 75 FR 76036 - Bostik, Inc. Formerly Known as ATO Findley Marshall, MI; Amended Certification Regarding...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ... firm. The workers are engaged in the production of adhesives and sealants. New information shows that... were adversely affected by a shift in the production of adhesives and sealants to the United Kingdom...

  17. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    PubMed

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  18. Exploring the determinants of secular decreases in dental caries among Korean children.

    PubMed

    Lee, Hye-Ju; Han, Dong-Hun

    2015-08-01

    The aim of this study was to determine the contributions of sealant and water fluoridation to the time trends in dental caries from 2003 to 2010. Data were from three waves of the Korean National Oral Health Surveys between 2003 and 2010, including a total of 23 059 children (11 889 boys and 11 170 girls) aged 8, 10, and 12 years. The impacts of sealant and water fluoridation on dental caries were obtained by logistic regression for each age group of children. The contributions of sealant and water fluoridation to the time trends in the prevalence of dental caries were examined by a series of logistic regression models, and changes in the adjusted odds ratios for each survey year were also calculated. Over the past 7 years, the prevalence of dental caries decreased dramatically. Although sealant had a significant impact on dental caries in each survey year, remarkable decreases in dental caries from 2003 to 2010 were not explained by the secular changes in the dental sealant or water fluoridation factor. We observed important population declines in dental caries in Korea in children aged 8-12 years; however, the likely causes for these secular trends remain to be determined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    PubMed Central

    Ferreira Junior, Rui Seabra

    2016-01-01

    Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA) without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS) at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons. PMID:27446617

  20. The utilization of dental hygiene students in school-based dental sealant programs.

    PubMed

    Miller, Faith Y

    2005-01-01

    Early detection of childhood caries is important to childrens' overall health. Untreated childhood caries can lead to pain, as in abscesses from prolonged neglect; altered dietary intake; and delays in the development of the permanent teeth if the primary teeth are prematurely lost. In the summer of 2000, funds were provided to various oral health care provider organizations by the Illinois Department of Public Health, Division of Oral Health, to purchase portable equipment to deliver preventive services (i.e., exams, sealants, and oral hygiene education) to second-grade and sixth-grade children who qualified for Medicaid and/or free and reduced-cost lunch programs. The Dental Sealant Grant Program at Southern Illinois University in Carbondale was a unique program that utilized dental hygiene students as the primary human resource. Within the state, the Dental Sealant Grant Program was, at the time of this report, the only grantee sponsored by a stand-alone dental hygiene program (not affiliated with a dental school). Other positive aspects of the dental hygiene-sponsored sealant program were that the supervising dentist was the primary Medicaid provider and a member of the dental hygiene faculty; dental hygiene faculty participated actively as site coordinators and clinicians; and dental hygiene students were given the opportunity to volunteer for the program as a service-learning option.

  1. Effect of application of an external teat sealant and/or oral treatment with a monensin capsule pre-calving on the prevalence and incidence of subclinical and clinical mastitis in dairy heifers.

    PubMed

    McDougall, S; Parker, K I; Weir, A M; Compton, C W R

    2008-06-01

    To assess the effect of applying an external teat sealant or a slow-release intraruminal monensin capsule pre-calving on the prevalence and incidence of subclinical or clinical mastitis in dairy heifers post-calving. The studies were undertaken in 13 herds. In two herds application of an external teat sealant was compared with a negative control; in nine herds treatment with monensin was compared with controls, and in two herds treatments were applied in a 2 x 2 factorial design. Heifers were randomly assigned within herd to be treated with a slow-release intraruminal device containing 32 g monensin (n=383), or left as untreated controls (n=389), approximately 30 days before the start of the spring calving period; or to be treated with a latex external teat sealant (n=206) when calving was impending, or be left as untreated controls (n=205). Milk samples were collected from each gland between 0 and 5 days after calving and from any gland diagnosed with clinical mastitis. The effect of the treatments on the prevalence of intramammary infection (IMI), i.e. subclinical mastitis, and clinical mastitis were initially analysed at the univariate level, with associated variables (p<0.2) being used in construction of multivariable models. The prevalence of IMI was 18.4% at the gland level, and coagulase-negative staphylococci followed by Streptococcus uberis were the most common isolates. Treatment with an external teat sealant reduced the prevalence, compared with controls, of any IMI (12.1 (SE 1.7)% vs 16.5 (SE 2.1)%, respectively; p=0.05) or IMI caused by a major pathogen (3.8 (SE 0.8)% vs 6.0 (SE 1.1)%, respectively; p=0.05). Monensin treatment did not affect the prevalence of any IMI (p=0.68) or IMI due to a major pathogen (p=0.11). The cumulative incidence of clinical mastitis was 14.2%. Neither monensin treatment (p=0.47) nor application of an external teat sealant (p=0.71) altered the risk of clinical mastitis. There was no interaction between the monensin and external teat sealant in the two herds where the treatments were applied in a 2 x 2 factorial design. Application of an external teat sealant resulted in a lower prevalence of any IMI and of an IMI caused by a major pathogen. Despite monensin reducing the mobilisation of body tissue and the risk of subclinical ketosis, it had no effect on the prevalence or incidence of IMI or clinical mastitis. Application of an external teat sealant is an option for reducing the prevalence of IMI in pasture fed dairy heifers.

  2. Young adult smokers' perceptions of plain packs, numbered packs and pack inserts in Turkey: a focus group study.

    PubMed

    Mucan, Burcu; Moodie, Crawford

    2017-11-09

    The Turkish Government's 'National Tobacco Control Program 2015-2018' included plans to introduce plain packaging and also a ban on brand names on cigarette packs, allowing only assigned numbers on packs. We explored perceptions of these proposed measures, and also pack inserts with cessation messages, another novel way of using the packaging to communicate with consumers. Eight focus groups were conducted with 47 young adult smokers in Manisa and Kutahya (Turkey) in December 2016. Participants were shown three straight-edged plain cigarette packs, as required in Australia, and then three bevelled-edged plain packs, as permitted in the UK. They were then shown plain packs with numbers rather than brand names, and finally three pack inserts with messages encouraging quitting or offering tips on how to do so. Participants were asked about their perceptions of each. Plain packs were considered unappealing and off-putting, although the bevelled-edged packs were viewed more favourably than the straight-edged packs. Numbered packs were thought by some to diminish the appeal created by the brand name and potentially decrease interest among never smokers and newer smokers. Pack inserts were thought to have less of an impact than the on-pack warnings, but could potentially help discourage initiation and encourage cessation. That bevelled-edged plain packs were perceived more positively than straight-edged plain packs is relevant to countries planning to introduce plain packaging. The study provides a first insight into smokers' perceptions of a ban on brand names, which was perceived to reduce appeal among young people. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Evaluation of strategies to communicate harmful and potentially harmful constituent (HPHC) information through cigarette package inserts: a discrete choice experiment.

    PubMed

    Salloum, Ramzi G; Louviere, Jordan J; Getz, Kayla R; Islam, Farahnaz; Anshari, Dien; Cho, Yoojin; O'Connor, Richard J; Hammond, David; Thrasher, James F

    2017-07-13

    The US Food and Drug Administration (FDA) has regulatory authority to use inserts to communicate with consumers about harmful and potentially harmful constituents (HPHCs) in tobacco products; however, little is known about the most effective manner for presenting HPHC information. In a discrete choice experiment, participants evaluated eight choice sets, each of which showed two cigarette packages from four different brands and tar levels (high vs low), accompanied by an insert that included between-subject manipulations (ie, listing of HPHCs vs grouping by disease outcome and numeric values ascribed to HPHCs vs no numbers) and within-subject manipulations (ie, 1 of 4 warning topics; statement linking an HPHC with disease vs statement with no HPHC link). For each choice set, participants were asked: (1) which package is more harmful and (2) which motivates them to not smoke; each with a 'no difference' option. Alternative-specific logit models regressed choice on attribute levels. 1212 participants were recruited from an online consumer panel (725 18-29-year-old smokers and susceptible non-smokers and 487 30-64-year-old smokers). Participants were more likely to endorse high-tar products as more harmful than low-tar products, with a greater effect when numeric HPHC information was present. Compared with a simple warning statement, the statement linking HPHCs with disease encouraged quit motivation. Numeric HPHC information on inserts appears to produce misunderstandings that some cigarettes are less harmful than others. Furthermore, brief narratives that link HPHCs to smoking-related disease may promote cessation versus communications that do not explicitly link HPHCs to disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Developing targets for radiation transport experiments at the Omega laser facility

    DOE PAGES

    Capelli, Deanna; Charsley-Groffman, C. A.; Randolph, Randall Blaine; ...

    2017-07-13

    Targets have been developed to measure supersonic radiation transport in aerogel foams using absorption spectroscopy. The target consists of an aerogel foam uniformly doped with either titanium or scandium inserted into an undoped aerogel foam package. This creates a localized doped foam region to provide spatial resolution for the measurement. Development and characterization of the foams is a key challenge in addition to machining and assembling the two foams so they mate without gaps. The foam package is inserted into a beryllium sleeve and mounted on a gold hohlraum. The target is mounted to a holder created using additive manufacturingmore » and mounted on a stalk. As a result, the manufacturing of the components, along with assembly and metrology of the target are described here.« less

  5. Developing targets for radiation transport experiments at the Omega laser facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Capelli, Deanna; Charsley-Groffman, C. A.; Randolph, Randall Blaine

    Targets have been developed to measure supersonic radiation transport in aerogel foams using absorption spectroscopy. The target consists of an aerogel foam uniformly doped with either titanium or scandium inserted into an undoped aerogel foam package. This creates a localized doped foam region to provide spatial resolution for the measurement. Development and characterization of the foams is a key challenge in addition to machining and assembling the two foams so they mate without gaps. The foam package is inserted into a beryllium sleeve and mounted on a gold hohlraum. The target is mounted to a holder created using additive manufacturingmore » and mounted on a stalk. As a result, the manufacturing of the components, along with assembly and metrology of the target are described here.« less

  6. 29 CFR 1910.103 - Hydrogen.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., threaded, socket, or compression fittings. Gaskets and thread sealants shall be suitable for hydrogen... closures. (v) Piping, tubing, and fittings. (a) Piping, tubing, and fittings and gasket and thread sealants... including process or analytical equipment. (c) Be located 25 feet from concentrations of people. (d) Be...

  7. Characterization of low temperature creep properties of crack sealants using bending beam rehometry.

    DOT National Transportation Integrated Search

    2009-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...

  8. Characterization of low temperature mechanical properties of crack sealants utilizing direct tension test.

    DOT National Transportation Integrated Search

    2008-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper : installation, crack sealants can extend pavement service life by three to five years. However, current : specifications for the selection of crack s...

  9. ART restorations and sealants placed in Chinese school children--results after three years.

    PubMed

    Holmgren, C J; Lo, E C; Hu, D; Wan, H

    2000-08-01

    These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.

  10. Effect of enamel sealants on tooth bleaching and on the color stability of the result.

    PubMed

    Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S

    2017-04-01

    The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.

  11. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel

    PubMed Central

    Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and Methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p<0.05. Results There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. Conclusions The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words:Pit and fissure sealant, Universal adhesive, Saliva. PMID:29670708

  12. Source apportionment and distribution of polycyclic aromatic hydrocarbons, risk considerations, and management implications for urban stormwater pond sediments in Minnesota, USA.

    PubMed

    Crane, Judy L

    2014-02-01

    High concentrations of polycyclic aromatic hydrocarbons (PAHs) are accumulating in many urban stormwater ponds in Minnesota, resulting in either expensive disposal of the excavated sediment or deferred maintenance by economically challenged municipalities. Fifteen stormwater ponds in the Minneapolis-St. Paul, MN, metropolitan area were studied to determine sources of PAHs to bed sediments through the application of several environmental forensic techniques, including a contaminant mass balance receptor model. The model results were quite robust and indicated that coal tar-based sealant (CT-sealant) particulate washoff and dust sources were the most important sources of PAHs (67.1%), followed by vehicle-related sources (29.5%), and pine wood combustion particles (3.4%). The distribution of 34 parent and alkylated PAHs was also evaluated regarding ancillary measurements of black carbon, total organic carbon, and particle size classes. None of these parameters were significantly different based on major land-use classifications (i.e., residential, commercial, and industrial) for pond watersheds. PAH contamination in three stormwater ponds was high enough to present a risk to benthic invertebrates, whereas nine ponds exceeded human health risk-based benchmarks that would prompt more expensive disposal of dredged sediment. The State of Minnesota has been addressing the broader issue of PAH-contaminated stormwater ponds by encouraging local municipalities to ban CT-sealants (29 in all) and to promote pollution prevention alternatives to businesses and homeowners, such as switching to asphalt-based sealants. A statewide CT-sealant ban was recently enacted. Other local and regional jurisdictions may benefit from using Minnesota's approach where CT-sealants are still used.

  13. Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.

    PubMed

    Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S

    2007-01-01

    This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.

  14. Survival of atraumatic restorative treatment (ART) sealants and restorations: a meta-analysis.

    PubMed

    de Amorim, Rodrigo G; Leal, Soraya C; Frencken, Jo E

    2012-04-01

    The purpose of this study is to perform a systematic investigation plus meta-analysis into survival of atraumatic restorative treatment (ART) sealants and restorations using high-viscosity glass ionomers and to compare the results with those from the 2005 ART meta-analysis. Until February 2010, four databases were searched. Two hundred four publications were found, and 66 reported on ART restorations or sealant survival. Based on five exclusion criteria, two independent reviewers selected the 29 publications that accounted for the meta-analysis. Confidence intervals (CI) and or standard errors were calculated and the heterogeneity variance of the survival rates was estimated. Location (school/clinic) was an independent variable. The survival rates of single-surface and multiple-surface ART restorations in primary teeth over the first 2 years were 93% (CI, 91-94%) and 62% (CI, 51-73%), respectively; for single-surface ART restorations in permanent teeth over the first 3 and 5 years it was 85% (CI, 77-91%) and 80% (CI, 76-83%), respectively and for multiple-surface ART restorations in permanent teeth over 1 year it was 86% (CI, 59-98%). The mean annual dentine lesion incidence rate, in pits and fissures previously sealed using ART, over the first 3 years was 1%. No location effect and no differences between the 2005 and 2010 survival rates of ART restorations and sealants were observed. The short-term survival rates of single-surface ART restorations in primary and permanent teeth, and the caries-preventive effect of ART sealants were high. ART can safely be used in single-surface cavities in both primary and permanent teeth. ART sealants have a high caries preventive effect.

  15. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    PubMed

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p <0.05. There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  16. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations

    PubMed Central

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Objective: Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Materials and Methods: Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5–55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal–Wallis and Bonferroni–Dunn test. Results: The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni–Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). Conclusion: The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition. PMID:27095890

  17. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS

    EPA Science Inventory

    The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...

  18. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    PubMed

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  19. Fabrication of gas impervious edge seal for a bipolar gas distribution assembly for use in a fuel cell

    DOEpatents

    Kaufman, Arthur; Werth, John

    1986-01-01

    A bipolar gas reactant distribution assembly for use in a fuel cell is disclosed, the assembly having a solid edge seal to prevent leakage of gaseous reactants wherein a pair of porous plates are provided with peripheral slits generally parallel to, and spaced apart from two edges of the plate, the slit being filled with a solid, fusible, gas impervious edge sealing compound. The plates are assembled with opposite faces adjacent one another with a layer of a fusible sealant material therebetween the slits in the individual plates being approximately perpendicular to one another. The plates are bonded to each other by the simultaneous application of heat and pressure to cause a redistribution of the sealant into the pores of the adjacent plate surfaces and to cause the edge sealing compound to flow and impregnate the region of the plates adjacent the slits and comingle with the sealant layer material to form a continuous layer of sealant along the edges of the assembled plates.

  20. Effectiveness of a new gelatin sealant system for dural closure.

    PubMed

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  1. Measuring quality of dental care: Caries prevention services for children.

    PubMed

    Herndon, Jill Boylston; Tomar, Scott L; Catalanotto, Frank A; Rudner, Nancy; Huang, I-Chan; Aravamudhan, Krishna; Shenkman, Elizabeth A; Crall, James J

    2015-08-01

    The authors conducted a study to validate the following 3 evidence-based, process-of-care quality measures focused on dental caries prevention for children with an elevated risk of experiencing caries: sealants for 6- to 9-year-olds, sealants for 10- to 14-year-olds, and topical fluoride. Using evidence-based guidelines, the Dental Quality Alliance developed measures for implementation with administrative data at the plan and program levels. To validate the measures, the authors used data from the Florida and Texas Medicaid programs and Children's Health Insurance Programs and from national commercial dental benefit plans. Data were extracted from 414 randomly selected dental office records to validate the use of administrative data to accurately calculate the measures. The authors also assessed statistically significant variations in overall measure performance. Agreement between administrative data and dental records was 95% for sealants (κ = 0.82) and 90% for topical fluoride (κ = 0.78). Sensitivity and specificity were 90.7% and 88.5% for topical fluoride and 77.8% and 98.8% for sealants, respectively. Variation in overall measure performance was greatest for topical fluoride (χ(2) = 5,887.1; P < .01); 18% to 37% of children with an elevated risk of experiencing caries received at least 2 topical fluoride applications during the reporting year. Although there was greater variation in performance for sealants for 6- to 9-year-olds (range, 21.0-31.3%; χ(2) = 548.6; P < .01) compared with sealants for 10- to 14-year-olds (range, 8.4-11.1%; χ(2) = 22.7; P < .01), overall sealant placement rates were lower for 10- to 14-year-olds. These evidence-based, caries prevention process-of-care quality measures can be implemented feasibly and validly using administrative claims data. The measures can be used to assess, monitor, and improve the proportion of children with an elevated risk of experiencing dental caries who receive evidence-based caries prevention services. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  2. TRICARE; Revision of Nonparticipating Providers Reimbursement Rate; Removal of Cost Share for Dental Sealants; TRICARE Dental Program. Final rule.

    PubMed

    2016-03-07

    This final rule revises the benefit payment provision for nonparticipating providers to more closely mirror industry practices by requiring TDP nonparticipating providers to be reimbursed (minus the appropriate cost-share) at the lesser of billed charges or the network maximum allowable charge for similar services in that same locality (region) or state. This rule also updates the regulatory provisions regarding dental sealants to clearly categorize them as a preventive service and, consequently, eliminate the current 20 percent cost-share applicable to sealants to conform with the language in the regulation to the statute.

  3. Development of performance-based guidelines for selection of bituminous-based hot-poured pavement crack sealant : an executive summary report.

    DOT National Transportation Integrated Search

    2009-01-01

    This report summarizes research presented in separate technical reports, papers, and journal articles that collectively document the development of a systematic process to aid in the selection of appropriate bituminous hot-poured sealants for pavemen...

  4. 78 FR 76984 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that exists in the window's extruded sections. This AD was prompted by jettison tests during routine maintenance inspections that showed the windows failed to jettison. The actions of this AD are intended to...

  5. 78 FR 37156 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that exists in the window's extruded sections. This proposed AD is prompted by jettison tests during routine maintenance inspections that showed the windows failed to jettison. The proposed actions are intended to...

  6. Dental Pit and Fissure Sealants: Implications for School Health Personnel.

    ERIC Educational Resources Information Center

    McCormack-Brown, K. R.; And Others

    1989-01-01

    To promote good personal hygiene practices in students, school health personnel must be informed about dental pit and fissure sealants and related programs. Adoption and maintenance of such programs may depend on the success of school health personnel in educating administrators and policymakers. (SM)

  7. 76 FR 53369 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... Implementation Plan (SIP) revision submitted by the Commonwealth of Pennsylvania. The SIP revision pertains to... volatile organic compounds (VOC) from the manufacture, sale, use, or application of adhesives, sealants...

  8. Is fibrin sealant effective and safe in total knee arthroplasty? A meta-analysis of randomized trials

    PubMed Central

    2014-01-01

    The objective of this study was to evaluate the efficacy and safety of fibrin sealant in patients following total knee arthroplasty (TKA). A comprehensive literature search of the electronic databases PubMed, MEDLINE, Web of Science, and Cochrane Library for published randomized controlled trials (RCTs) was undertaken. The evidence base was critically appraised using a tool from the Cochrane Bone, Joint and Muscle Trauma Group. Eight RCTs involving 641 patients were included. The use of fibrin sealant significantly reduced postoperative drainage (weighted mean difference (WMD) −346, 95% confidence interval (CI) −496.29 to −197.54, P < 0.00001) and blood transfusions (risk ratio (RR) 0.47, 95% CI 0.35 to 0.63, P < 0.00001) and led to a significant improvement in the range of motion (WMD 16.59, 95% CI 6.92 to 26.25, P = 0.0008). However, using fibrin sealant did not significantly reduced total blood loss (WMD −305.25, 95% CI −679.44 to 68.95, P = 0.11). Regarding complications, there were no significant differences in any adverse events, fever, infection, or hematoma among the study groups. In conclusion, the present meta-analysis indicates that the use of fibrin sealant was effective and safe as a hemostatic therapy for patients with TKA. PMID:24884626

  9. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...

  10. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2002-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  11. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2004-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  12. Copolymer sealant compositions and method for making

    NASA Technical Reports Server (NTRS)

    Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)

    2003-01-01

    Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.

  13. EVALUATING THE POTENTIAL EFFICACY OF AN ANTIMICROBIAL-CONTAINING SEALANT ON DUCT LINER AND GALVANIZED STEEL

    EPA Science Inventory

    The article gives results of an evaluation of the potential efficacy of an antimicrobial-containing sealant on fibrous-glass duct liner (FGDL) and galvanized steel (GS) as used in heating, ventilating, and air-conditioning (HVAC) systems. HVAC systems become dirty to various degr...

  14. 75 FR 80340 - Approval and Promulgation of Implementation Plans; New Jersey; 8-Hour Ozone Control Measures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ..., ``Prevention of Air Pollution From Adhesives, Sealants, Adhesive Primers and Sealant Primers,'' and Subchapter... revisions to Subchapter 23, ``Prevention of Air Pollution From Architectural Coatings,'' Subchapter 24, ``Prevention of Air Pollution From Consumer Products,'' and Subchapter 25, ``Control and Prohibition of Air...

  15. 75 FR 53277 - Notice of Intent To Terminate Selected National Voluntary Laboratory Accreditation Program (NVLAP...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    ... coatings, paper and related products, building seals and sealants, plastics, plumbing, roofing, and... products, building seals and sealants, plastics, plumbing, roofing, and mattresses. The purpose of this... plumbing laboratories are also accredited for plastic and paint testing in support of plumbing testing...

  16. Pilot Fullerton prepares meal on middeck

    NASA Image and Video Library

    1982-03-30

    STS003-26-253 (30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communications kit assembly (assy) mini-headset (HDST), prepares meal on middeck. Fullerton clips corner of rehydratable food (cereal) package with scissors. The opening will allow Fullerton to insert JSC water dispenser kit water gun in order to heat contents with hot water. Meal tray assembly is secured to forward middeck locker and holds additional food packages and beverage containers. Photo credit: NASA

  17. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    PubMed Central

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  18. Determining ultra-low moisture permeation measurement for sealants on OLED encapsulation

    NASA Astrophysics Data System (ADS)

    Choi, Byung Il; Woo, Sang Bong; Kim, Jong Chul; Kim, Seung Hun; Seo, Sang Joon

    2012-12-01

    As the next-generation flexible display elements are very vulnerable to moisture, securing proper encapsulation is a decisive factor in enabling a long working life. Therefore, together with the recent development of plastic barrier films with very low permeabilities, interest in the permeabilities of sealants used for perimetric sealing has been increasing. In this study, equipment with a resolution of approximately ˜10-7 g·day-1 to measure moisture permeability in perimetric sealing was established, and the permeabilities of different sealants were measured. This equipment could have applications not only in the display industry but also in other sectors requiring encapsulation technology, such as the semiconductor and solar cell industries.

  19. Safety and usability of hemostats, sealants, and adhesives.

    PubMed

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  20. New generation tissue sealants and hemostatic agents: innovative urologic applications.

    PubMed

    Traver, Michael A; Assimos, Dean G

    2006-01-01

    Control of blood loss during urologic surgery is paramount to the success of patient recovery. Hemostatic agents and tissue sealants are used routinely to prevent excess blood loss and in reconstruction during surgical repair. Some of the available products include thrombin sealant, fibrin glue, bovine serum/albumin/glutaraldehyde, and gelatin matrix. Each of these agents differs in mechanism, cost, and application. Complications can include allergic reactions or thromboembolism and the risk of contracting bovine spongiform encephalitis or hepatitis. Many new hemostatic agents are being developed and approved. The benefits and risks of use of these agents versus conventional treatment need to be considered on a case-by-case basis by the surgeon.

  1. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    PubMed

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  2. Multi-layer light-weight protective coating and method for application

    NASA Technical Reports Server (NTRS)

    Wiedemann, Karl E. (Inventor); Clark, Ronald K. (Inventor); Taylor, Patrick J. (Inventor)

    1992-01-01

    A thin, light-weight, multi-layer coating is provided for protecting metals and their alloys from environmental attack at high temperatures. A reaction barrier is applied to the metal substrate and a diffusion barrier is then applied to the reaction barrier. A sealant layer may also be applied to the diffusion barrier if desired. The reaction barrier is either non-reactive or passivating with respect to the metal substrate and the diffusion barrier. The diffusion barrier is either non-reactive or passivating with respect to the reaction barrier and the sealant layer. The sealant layer is immiscible with the diffusion barrier and has a softening point below the expected use temperature of the metal.

  3. Application of Au-Sn eutectic bonding in hermetic radio-frequency microelectromechanical system wafer level packaging

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Choa, Sung-Hoon; Kim, Woonbae; Hwang, Junsik; Ham, Sukjin; Moon, Changyoul

    2006-03-01

    Development of packaging is one of the critical issues toward realizing commercialization of radio-frequency-microelectromechanical system (RF-MEMS) devices. The RF-MEMS package should be designed to have small size, hermetic protection, good RF performance, and high reliability. In addition, packaging should be conducted at sufficiently low temperature. In this paper, a low-temperature hermetic wafer level packaging scheme for the RF-MEMS devices is presented. For hermetic sealing, Au-Sn eutectic bonding technology at temperatures below 300°C is used. Au-Sn multilayer metallization with a square loop of 70 µm in width is performed. The electrical feed-through is achieved by the vertical through-hole via filling with electroplated Cu. The size of the MEMS package is 1 mm × 1 mm × 700 µm. The shear strength and hermeticity of the package satisfies the requirements of MIL-STD-883F. Any organic gases or contamination are not observed inside the package. The total insertion loss for the packaging is 0.075 dB at 2 GHz. Furthermore, the robustness of the package is demonstrated by observing no performance degradation and physical damage of the package after several reliability tests.

  4. Development of Multifunctional Active Film and Its Application in Modified Atmosphere Packaging of Shiitake Mushrooms.

    PubMed

    Wang, Hong Jiang; An, Duck Soon; Lee, Dong Sun

    2016-09-01

    Agar-based films with multiple functions (CO 2 absorption, water vapor absorption, and antimicrobial activity) were developed, tested for their properties, and then applied to the packaging of fresh shiitake mushrooms as an insert label. The films were cast from an agar-based aqueous solution containing a dissolving plasticizer (glycerol), a CO 2 absorbent (sodium carbonate [SC] alone or a combination of SC and sodium glycinate [SC-SG]), and a volatile antimicrobial agent (carvacrol [CRV]). The agar of the film matrix is designed to serve as a water vapor absorbent. The multifunctional films tended to have poor mechanical properties, with a hard texture and an opaque and yellowish color. The CO 2 absorbent, either SC alone or SC-SG, affected CRV retention and release along with the CO 2 and water vapor absorption behavior. Both films (SC-CRV and SC-SG-CRV films) showed good inhibitory effects against Pseudomonas fluorescens and Saccharomyces cerevisiae . SC-CRV film had a higher and faster CO 2 absorption property, higher retention and extended release of CRV, and lower and slower water vapor absorption and was assessed to be better suited for use in shiitake mushroom packaging. The packaging in which the SC-CRV film with an appropriate amount of CRV was used as an insert label was able to generate the desired atmosphere and less moisture condensation inside the package, producing the best preservation of quality in terms of mushroom color, firmness, flavor score, and microbial counts after 6 days of storage at 10°C. A tailored modified atmosphere packaging system using multifunctional film would be useful in the preservation of CO 2 -sensitive fresh commodities.

  5. Evaluating cyclic fatigue of sealants during outdoor testing

    Treesearch

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2009-01-01

    A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...

  6. 76 FR 79537 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-22

    ... Division, U.S. Environmental Protection Agency, Region III, 1650 Arch Street, Philadelphia, Pennsylvania...--Adhesives and Sealants under Regulation 1141--Limiting Emissions of Volatile Organic Compounds from Consumer.... The revision is part of Delaware's strategy to achieve and maintain the 8- hour ozone national ambient...

  7. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS: JOURNAL ARTICLE

    EPA Science Inventory

    NRMRL-RTP-P- 530a Foarde, K.K., VanOsdell, D.W., and Menetrez*, M.Y. Investigation of the Potential Antimicrobial Efficacy of Sealants Used in HVAC Systems. Published in: Journal of Air and Waste Management Association 51 (8):1219-1226 (2001). 07/06/2000 The paper gives result...

  8. 78 FR 27953 - Notification of Proposed Production Activity, CNH America, LLC, Subzone 59B, (Agricultural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ....14(b), FTZ activity would be limited to the specific foreign-status materials and components and... housings; vertical auger tubes; chopper drive gearbox accessories; cotton picker frames and cabs; and, non... components and materials sourced from abroad include: sealant; sealant paste; oil drain assemblies; rubber...

  9. An accelerated exposure and testing apparatus for building joint sealants

    NASA Astrophysics Data System (ADS)

    White, C. C.; Hunston, D. L.; Tan, K. T.; Hettenhouser, J.; Garver, J. D.

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  10. An accelerated exposure and testing apparatus for building joint sealants.

    PubMed

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  11. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    PubMed

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    PubMed

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P < 0.01): 93% compared with 74% at six months, 81% compared with 65% at 12 months, and 83% compared with 58% at 24 months. When analyzed according to age range, the difference between the retention rates was statistically significant in the five- to 10-year-olds but not significant in the 11- to 16-year-olds. The conclusion reached in this study was that cermet cement was better retained than conventional resin sealants in younger children.

  13. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    PubMed

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P < .001), independently of the length of the resection. Prolonged air leak and mean duration of drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P < .001). Autologous fibrin sealant for reinforcement of the staple lines after lung volume reduction surgery significantly reduces prolonged air leak and duration of chest tube drainage.

  14. Prevention of internal hernias and pelvic adhesions following laparoscopic left-sided colorectal resection: the role of fibrin sealant.

    PubMed

    Angelini, Pierluigi; Sciuto, Antonio; Cuccurullo, Diego; Pirozzi, Felice; Reggio, Stefano; Corcione, Francesco

    2017-07-01

    Laparoscopy has increasingly become the standard of care for patients who undergo colorectal surgery for both benign and malignant diseases. This growing experience has also resulted in more reports of postoperative complications from the minimally invasive approach to primary colorectal resection. Small bowel obstruction from internal hernias and pre-sacral adhesions is an uncommon but not negligible complication. However, there is little literature specific to this topic with recommendations for different methods to prevent it. We report our original technique of closing the mesenteric defect and covering the pre-sacral fascia by using fibrin sealant to prevent this complication. From January 2005 to December 2014, a total of 1079 patients underwent elective laparoscopic left colorectal resection (left hemicolectomy or anterior rectal resection) in our department. In the first 298 procedures, the mesenteric defect was left open, while in the following 781 procedures, it was closed using fibrin sealant with the aim of preventing postoperative small bowel obstruction. Among the first 298 patients, three (1%) required reoperation for small bowel obstruction due to internal hernia (0.33%) or critical pre-sacral adhesions (0.66%). These complications did not occur in the subsequent series in which all 781 patients were treated with fibrin sealant prophylactic closure of the mesenteric defect. In our experience, fibrin sealant closure of the mesenteric defect has demonstrated to be safe and effective in preventing postoperative small bowel obstruction that remains a complication both in open and in laparoscopic colorectal surgeries.

  15. Use of fibrin sealants for the localized, controlled release of cefazolin

    PubMed Central

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  16. Effect of artificial aging on the bond durability of fissure sealants.

    PubMed

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p < 0.05). Longer thermocycling (10,000 cycles) resulted in more decreases in µTBS for group PEL and PPC, while the strength of the UX group remained relatively unchanged. After thermocycling, considerable silver penetration could be seen at the sealant/enamel interface of the EL group in micro-CT images. The etch-and-rinse procedure for sealant application promotes higher bond strength under artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  17. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    PubMed

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  18. Atomic force microscopy and tridimensional topography analysis of human enamel after resinous infiltration and storage in water.

    PubMed

    Taher, Nadia M

    2013-04-01

    To evaluate the effect of water storage on surface roughness (Ra) of human enamel after treatment with resin infiltrant and fissure sealant, by utilizing atomic force microscopy (AFM) and microtomography. This study was conducted after registration and ethical approval clarification at the College of Dentistry Research Center, King Saud University, Riyadh, Kingdom of Saudi Arabia between January 2011 and August 2011. Thirty enamel surface specimens were prepared from caries-free human premolar teeth. Specimens were divided into 3 groups: Group I, was the control; Group II, a resin infiltrant (Icon) was applied on the enamel surfaces; and Group III, the teeth were treated with fissure sealant (SealRite). All specimens were stored in distilled water for 6 months and then, subjected to AFM Veeco CP11 1.2 analysis. A few specimens were scanned by skyscan-1072-x-ray microtomography. The Ra mean readings were recorded and statistical analysis was performed with the Statistical Package for Social Sciences Version 16 at the significance level of p<0.05. No significant differences in the mean Ra were recorded among the 3 groups, (Group I = 0.21+/-0.057), (Group II = 0.23+/-0.075), and (Group III = 0.20+/-0.039) at p=0.747. The AFM images of enamel surface show thin and inhomogeneous Icon resin in Group II, meanwhile, the SealRite in Group III showed a homogeneous layer in all specimens. The microtomography supported the findings of the AFM images. The persistence of the SealRite in all specimens revealed its low solubility in water and its protective effect on enamel surface.

  19. 9 CFR 381.123 - Official inspection mark; official establishment number.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... label of a canned product, or on other packaging or labeling in the container, e.g., on aluminum pans... insert label placed under a transparent covering if clearly visible and legible and accompanied by the...

  20. 9 CFR 381.123 - Official inspection mark; official establishment number.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... label of a canned product, or on other packaging or labeling in the container, e.g., on aluminum pans... insert label placed under a transparent covering if clearly visible and legible and accompanied by the...

  1. Durability of sealants exposed to outdoor weathering and hot compression cycles

    Treesearch

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston

    2011-01-01

    Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...

  2. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Treesearch

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  3. Viscous sealing glass compositions for solid oxide fuel cells

    DOEpatents

    Kim, Cheol Woon; Brow, Richard K.

    2016-12-27

    A sealant for forming a seal between at least two solid oxide fuel cell components wherein the sealant comprises a glass material comprising B.sub.2O.sub.3 as a principal glass former, BaO, and other components and wherein the glass material is substantially alkali-free and contains less than 30% crystalline material.

  4. A fibrin sealant for perforated and preperforated corneal ulcers.

    PubMed Central

    Lagoutte, F M; Gauthier, L; Comte, P R

    1989-01-01

    Fibrin sealant is used to close perforated or preperforated corneal ulcers. In addition to the usual advantages of cyanoacrylates it is degraded physiologically and provides a good support for corneal healing. Corneal grafting can be avoided when contraindicated or postponed when conditions allow. This technique has been successful in nine eyes of eight patients. Images PMID:2804032

  5. 76 FR 6533 - Airworthiness Directives; Hawker Beechcraft Corporation (Type Certificate Previously Held by...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for the products listed above. This AD requires a detailed inspection for proper sealant of the left and right... sealant on the left and right pylon firewall structures. We are issuing this AD to detect and correct...

  6. Gel sealants for the mitigation of spontaneous heatings in coal mines. Report of investigations/1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miron, Y.

    1995-12-31

    The U.S. Bureau of Mines evaluated three sealant systems for this purpose, bentonite-water mixtures, silicate gel, and guar gum gels. The guar gum-based gel was the only sealant that possessed the desired properties of elasticity, ease of preparation, adaptability to the mine, and a long life. In addition, since the gel consists mostly of water, it could quench or cool nearby heatings. Optimal formulations were determined in laboratory tests, and then tested in the U.S. Bureau of Mines` Safety Research Coal Mine. Two formulations resulted in stable gels that lasted for at least 12 months in the mine. Semi-continuous preparationmore » of gel using an eductor was evaluated and appears feasible.« less

  7. First impressions about Adherus, a new dural sealant.

    PubMed

    Zoia, Cesare; Bongetta, Daniele; Lombardi, Francesco; Custodi, Viola Marta; Pugliese, Raffaelino; Gaetani, Paolo

    2015-12-18

    The aim of the study is to report our first impressions about Adherus, a novel dural sealant, used in neurosurgical endoscopic transnasal procedures. We retrospectively reviewed the clinical and surgical records of the first 11 patients with intraoperative high-flow cerebrospinal fluid leak treated with the aid of Adherus at our center between February and October 2014. The healing at the level of the dural plasty was monitored and evaluated radiologically and with regular endoscopic inspections. With a median follow-up of 210 days, no postoperative CSF leak or surgical site infections were found in any of the cases. Based on our preliminary experience, this new dural sealant seems to provide an effective aid in dural plasty during endoscopic transphenoidal procedures.

  8. Microbial viability in preparations packaged for single use.

    PubMed

    Obayashi, Akiko; Oie, Shigeharu; Kamiya, Akira

    2003-05-01

    We evaluated microbial viability in preparations packaged for single use only which mandate that residual solution be discarded such as albumin and globulin preparations as blood products, preparations containing albumin (such as urokinase and interferon), fat emulsions, and a preparation containing fat emulsions (propofol). In most preparations, Serratia marcescens and Burkholderia cepacia proliferated rapidly at 30 degrees C. However, in globulin preparations containing 1-2.25% glycine to prevent protein degradation (Gamma-Venin P, Venilon-I, Globulin Injection, and Ahlbulin), no growth of S. marcescens and B. cepacia was detected over 24 h at 30 degrees C. For globulin preparations containing 1-2.25% glycine, the injunction to "Discard residual solution after the package has been used" in the package inserts can be revised to "It is possible to use residual solution within 24 h after the package has been used with storage in a cool place."

  9. Method of forming a package for MEMS-based fuel cell

    DOEpatents

    Morse, Jeffrey D; Jankowski, Alan F

    2013-05-21

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  10. Method of forming a package for mems-based fuel cell

    DOEpatents

    Morse, Jeffrey D.; Jankowski, Alan F.

    2004-11-23

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMOS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  11. Evaluation of School-Based Dental Sealant Programs: An Updated Community Guide Systematic Economic Review.

    PubMed

    Griffin, Susan O; Naavaal, Shillpa; Scherrer, Christina; Patel, Mona; Chattopadhyay, Sajal

    2017-03-01

    A recently updated Community Guide systematic review of the effectiveness of school sealant programs (SSPs) still found strong evidence that SSPs reduced dental caries among schoolchildren. This follow-up systematic review updates SSP cost and benefit information from the original 2002 review. Using Community Guide economic review methods, the authors searched the literature from January 2000 to November 20, 2014. The final body of evidence included 14 studies-ten from the current search and four with cost information from the 2002 review. Nine studies had information on SSP costs; six on sealant benefit (averted treatment costs and productivity losses); four on SSP net cost (cost minus benefit); and three on net cost to Medicaid of clinically delivered sealants. The authors imputed productivity losses and discounted costs/outcomes when this information was missing. The analysis, conducted in 2015, reported all values in 2014 U.S. dollars. The median one-time SSP cost per tooth sealed was $11.64. Labor accounted for two thirds of costs, and time to provide sealants was a major cost driver. The median annual economic benefit was $6.29, suggesting that over 4 years the SSP benefit ($23.37 at a 3% discount rate) would exceed costs by $11.73 per sealed tooth. In addition, two of four economic models and all three analyses of Medicaid claims data found that SSP benefit to society exceeded SSP cost. Recent evidence indicates the benefits of SSPs exceed their costs when SSPs target schools attended by a large number of high-risk children. Published by Elsevier Inc.

  12. Abrasion Plus Local Fibrin Sealant Instillation Produces Pleurodesis Similar to Pleurectomy in Rabbits.

    PubMed

    Marchi, Evaldo; de Carvalho, Marcus V H; Ventureli, Tiago R; Fruchi, Andre J; Lazaro, Ariane; do Carmo, Deborah C; Barreto, Thayssa Y A S; Dias, Bruno V B; Acencio, Milena M P; Teixeira, Lisete R; Light, Richard W

    2016-09-01

    Pleurodesis performed either by pleurectomy or pleural abrasion is recommended in the approach to primary spontaneous pneumothorax to avoid recurrence. However, the efficacy of parietal pleural abrasion in producing pleurodesis is questioned. This study aims to determine the efficacy of apical abrasion alone, abrasion plus fibrin sealant application, and pleurectomy in producing pleurodesis in rabbits. Rabbits were subjected to video-assisted thoracic surgery alone (control) or to video-assisted thoracic surgery with apical gauze abrasion, abrasion plus fibrin sealant instillation, or apical pleurectomy. Blood samples were collected preoperatively and 48 h and 28 days postoperatively to measure total leukocytes (white blood cell count), neutrophil counts, and serum interleukin (IL)-8 levels. After 28 days the animals were sacrificed for macroscopic evaluation of the degree of apical pleurodesis and microscopic evaluation of local pleural fibrosis and collagen deposition. White blood cell and neutrophil counts were similar in all groups, whereas the serum IL-8 level peaked at 48 h in all groups and decreased after 28 days, except in the pleurectomy group. After 28 days the abrasion plus fibrin sealant and pleurectomy groups had significantly more pleural adhesions, pleural fibrosis, and collagen deposition than the abrasion alone group, mainly due to thick mature fibers. Abrasion with local fibrin sealant instillation is as effective as pleurectomy in producing pleurodesis in rabbits. Apical pleurectomy elicits a more persistent elevation of serum IL-8 levels than apical abrasion alone or abrasion plus fibrin adhesive instillation. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  13. PAH concentrations in lake sediment decline following ban on coal-tar-based pavement sealants in Austin, Texas

    USGS Publications Warehouse

    Van Metre, Peter C.; Mahler, Barbara J.

    2013-01-01

    Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.

  14. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  15. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  16. Development of test apparatus for service life prediction of sealant formulations and evaluation of data from 18 months of outdoor weathering

    Treesearch

    R. Sam Williams; Steve Lacher; Corey Halpin; Christopher White

    2004-01-01

    The focus of this report is to describe the results from seven different sealant formulations exposed for up to 18 months. The methods used to evaluate the data are described, the difficulties encountered in analyzing the data are discussed, and new developments in the test apparatus are presented.

  17. Effect of surface sealants on microleakage of Class II restorations after thermocycling and long-term water storage.

    PubMed

    Lima, Adriano Fonseca; Soares, Giulliana Panfiglio; Vasconcellos, Pedro Henrique; Ambrosano, Gláucia Maria; Marchi, Giselle Maria; Lovadino, José Roberto; Aguiar, Flávio Henrique

    2011-06-01

    To evaluate interface degradation leading to marginal microleakeage in Class II restorations that had received an application of surface sealant at the tooth/restoration interface or not. Eighty bovine incisors were used, and the teeth were split obliquely, 10 mm from the amelodentinal proximal junction, and finished with water abrasive papers to obtain a smooth, flat incisal surface. Cavities were made to simulate Class II preparations (8 mm high, 4 mm wide and 1.5 mm deep), and the restorations were performed with a composite resin. Teeth were then randomly allocated into 8 groups according to the surface sealant (none, Fortify, Single Bond 2, or Scothbond MP Plus) and aging process (none or thermocycling and storage for 6 months). Microleakage was then evaluated using a dye penetration method immediately after the restoration or after aging. The samples were triturated and assessed by spectrophotometer. Microleakage was statistically similar in all groups when assessed immediately after the restorative procedure. After aging, teeth sealed with Fortify presented better results than the other groups. Aging causes interface degradation and increased microleakage. Surface sealant can reduce these effects and decrease microleakage in Class II restorations.

  18. Method for sealing an ultracapacitor, and related articles

    DOEpatents

    Day, James; Shapiro, Andrew Philip; Jerabek, Elihu Calvin

    2000-08-29

    An improved process for sealing at least one ultracapacitor which includes a multi-layer structure is disclosed. The process includes the step of applying a substantial vacuum to press together an uppermost layer of the structure and a lowermost layer of the structure and to evacuate ambient gasses, wherein a sealant situated in a peripheral area between the facing surfaces of the layers forms a liquid-impermeable seal for the structure under the vacuum. In some embodiments, a press is used to apply pressure to the peripheral area on which the sealant is disposed. Usually, the ultracapacitor would be situated within an enclosable region of the press, and a collapsible membrane would be fastened over the ultracapacitor to fully enclose the region and transmit the vacuum force to the multi-layer structure. The force applied by the press itself causes the sealant to flow, thereby ensuring a complete seal upon curing of the sealant. This process can be employed to seal one ultracapacitor or a stack of at least two ultracapacitors. Another embodiment of this invention is directed to an apparatus for sealing a multi-layer ultracapacitor, comprising the elements described above.

  19. Studies of new perfluoroether elastomeric sealants. [for aircraft fuel tanks

    NASA Technical Reports Server (NTRS)

    Basiulis, D. I.; Salisbury, D. P.

    1981-01-01

    Channel and filleting sealants were developed successfully from cyano and diamidoxime terminated perfluoro alkylene ether prepolymers. The prepolymers were polymerized, formulated and tested. The polymers and/or formulations therefrom were evaluated as to their physical, mechanical and chemical properties (i.e., specific gravity, hardness, nonvolatile content, corrosion resistance, stress corrosion, pressure rupture resistance, low temperature flexibility, gap sealing efficiency, tensile strength and elongation, dynamic mechanical behavior, compression set, fuel resistance, thermal properties and processability). Other applications of the formulated polymrs and incorporation of the basic prepolymers into other polymeric systems were investigated. A cyano terminated perfluoro alkylene oxide triazine was formulated and partially evaluated. The channel sealant in its present formulation has excellent pressure rupture resistance and surpasses present MIL specifications before and after fuel and heat aging.

  20. Effectiveness of a five-step method for teaching clinical skills to students in a dental college in India.

    PubMed

    Virdi, Mandeep S; Sood, Meenakshi

    2011-11-01

    This study conducted at the PDM Dental College and Research Institute, Haryana, India, had the purpose of developing a teaching method based upon a five-step method for teaching clinical skills to students proposed by the American College of Surgeons. This five-step teaching method was used to place fissure sealants as an initial procedure by dental students in clinics. The sealant retention was used as an objective evaluation of the skill learnt by the students. The sealant retention was 92 percent at six- and twelve-month evaluations and 90 percent at the eighteen-month evaluation. These results indicate that simple methods can be devised for teaching clinical skills and achieve high success rates in clinical procedures requiring multiple steps.

  1. Fibrin sealants: surgical hemostat, sealant and adhesive.

    PubMed

    Mandell, Samuel P; Gibran, Nicole S

    2014-06-01

    Fibrin sealants (FS) have been approved for use in the United States since 1998. Since approval, they have been used in a wide variety of clinical settings and new products continue to be introduced. This review covers the literature supporting the USA FDA-approved indications for FS products produced by Baxter Corp. Literature review of PubMed, the Cochrane Library, FDA approval documents and product websites yielded information contained in this article. Mechanism of action, efficacy and safety of these products are covered. FS are generally safe, popular and are used for a wide variety of off-label indications. Their use appears to be expanding rapidly. For many uses, including approved ones, large well-controlled trials are still needed. Additionally, cost-effectiveness data for these products would be a great benefit in guiding their future use.

  2. A Systematic Approach to the Study of Accelerated weathering of Building Joint Sealants

    Treesearch

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; James J. Filliben; Adam L. Pintar; Greg Schueneman

    2012-01-01

    An accurate service life prediction model is needed for building joint sealants in order to greatly reduce the time to market of a new product and reduce the risk of introducing a poorly performing product into the marketplace. A stepping stone to the success of this effort is the precise control of environmental variables in a laboratory accelerated test apparatus in...

  3. Requirements for Weatherproofing Thin Shell Concrete Roofs. Proceedings of the Conference of Building Research Institute, Division of Engineering and Industrial Research (Spring 1961).

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    Topics discussed include--(1) requirements for weatherproofing and sealant materials for thin shell concrete roof, (2) effect of physical factors on weatherproofing of thin shell concrete roofs, (3) problems and limitations imposed by thin shell concrete roofs and their effect on weatherproofing and sealant materials, and (4) properties and uses…

  4. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  5. Antimicrobial, antioxidant and sensory features of eugenol, carvacrol and trans-anethole in active packaging for organic ready-to-eat iceberg lettuce.

    PubMed

    Wieczyńska, Justyna; Cavoski, Ivana

    2018-09-01

    In this study, bio-based emitting sachets containing eugenol (EUG), carvacrol (CAR) and trans-anethole (ANT) were inserted into cellulose (CE) and polypropylene (PP) pillow packages of organic ready-to-eat (RTE) iceberg lettuce to investigate their functional features. EUG, CAR and ANT sachets in CE; and CAR in PP packages showed antimicrobial activities against coliforms (Δlog CFU g -1 of -1.38, -0.91, -0.93 and -0.93, respectively). EUG and ANT sachets in both packages reduced discoloration (ΔE of 9.5, 1.8, 9.4 and 5.6, respectively). ANT in both, and EUG only in PP packages induced biosynthesis of caffeoyl derivatives (C a T A , D i C a T A , D i C a Q A ), total phenolics and antioxidant activity (FRAP). Also, ANT and EUG in both packages improved overall freshness and odor. Principal component analysis separated ANT and EUG from CAR in both packages. The Pearson correlation confirmed that overall quality improvements were more pronounced by ANT inside the packages in comparison to EUG and CAR. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Body of Knowledge (BOK) for Leadless Quad Flat No-Lead/Bottom Termination Components (QFN/BTC) Package Trends and Reliability

    NASA Technical Reports Server (NTRS)

    Ghaffarian, Reza

    2014-01-01

    Bottom terminated components and quad flat no-lead (BTC/QFN) packages have been extensively used by commercial industry for more than a decade. Cost and performance advantages and the closeness of the packages to the boards make them especially unique for radio frequency (RF) applications. A number of high-reliability parts are now available in this style of package configuration. This report presents a summary of literature surveyed and provides a body of knowledge (BOK) gathered on the status of BTC/QFN and their advanced versions of multi-row QFN (MRQFN) packaging technologies. The report provides a comprehensive review of packaging trends and specifications on design, assembly, and reliability. Emphasis is placed on assembly reliability and associated key design and process parameters because they show lower life than standard leaded package assembly under thermal cycling exposures. Inspection of hidden solder joints for assuring quality is challenging and is similar to ball grid arrays (BGAs). Understanding the key BTC/QFN technology trends, applications, processing parameters, workmanship defects, and reliability behavior is important when judicially selecting and narrowing the follow-on packages for evaluation and testing, as well as for the low risk insertion in high-reliability applications.

  7. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters

    NASA Astrophysics Data System (ADS)

    Knapp, Roger G.; Adams, Neil J.

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  8. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters

    NASA Astrophysics Data System (ADS)

    Knapp, Roger Glenn

    1993-05-01

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  9. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  10. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  11. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  12. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  13. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  14. Influence of light-curing mode on the cytotoxicity of resin-based surface sealants.

    PubMed

    Wegehaupt, Florian J; Tauböck, Tobias T; Attin, Thomas; Belibasakis, Georgios N

    2014-05-06

    Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity. Bovine dentine discs were treated as follows: group 1: untreated, groups 2-5: Seal&Protect and groups 6-9: experimental sealer. Groups 2 and 6 were light-cured (VALO LED light-curing device) for 40 s (1000 mW/cm2), groups 3 and 7 for 10 s (1000 mW/cm2), groups 4 and 8 for 7 s (1400 mW/cm2) and groups 5 and 9 for 3 s (3200 mW/cm2). Later, materials were extracted in culture medium for 24 h, and released lactate dehydrogenase (LDH) activity as a measure of cytotoxicity was determined photometrically after cells (dental pulp cells and gingival fibroblasts) were exposed to the extracts for 24 h. Three independent experiments, for both sample preparation and cytotoxicity testing, were performed. Overall, lowest cytotoxicity was observed for the unsealed control group. No significant influence of light-curing settings on the cytotoxicity was observed (p = 0.537 and 0.838 for pulp cells and gingival fibroblasts, respectively). No significant difference in the cytotoxicity of the two sealants was observed after light-curing with same light-curing settings (group 2 vs. 6, 3 vs. 7, 4 vs. 8 and 5 vs. 9: p > 0.05, respectively). Shortening the light-curing time, while maintaining constant energy density, resulted in no higher cytotoxicity of the investigated sealants.

  15. Behavior of Aging, Micro-Void, and Self-Healing of Glass/Ceramic Materials and Its Effect on Mechanical Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenning N.; Sun, Xin; Khaleel, Mohammad A.

    This chapter first describes tests to investigate the temporal evolution of the volume fraction of ceramic phases, the evolution of micro-damage, and the self-healing behavior of the glass ceramic sealant used in SOFCs, then a phenomenological model based on mechanical analogs is developed to describe the temperature dependent Young’s modulus of glass ceramic seal materials. It was found that after the initial sintering process, further crystallization of the glass ceramic sealant does not stop, but slows down and reduces the residual glass content while boosting the ceramic crystalline content. Under the long-term operating environment, distinct fibrous and needle-like crystals inmore » the amorphous phase disappeared, and smeared/diffused phase boundaries between the glass phase and ceramic phase were observed. Meanwhile, the micro-damage was induced by the cooling-down process from the operating temperature to the room temperature, which can potentially degrade the mechanical properties of the glass/ceramic sealant. The glass/ceramic sealant self-healed upon reheating to the SOFC operating temperature, which can restore the mechanical performance of the glass/ceramic sealant. The phenomenological model developed here includes the effects of continuing aging and devitrification on the ceramic phase volume fraction and the resulted mechanical properties of glass ceramic seal material are considered. The effects of micro-voids and self-healing are also considered using a continuum damage mechanics (CDM) model. The formulation is for glass/ceramic seal in general, and it can be further developed to account for effects of various processing parameters. This model was applied to G18, and the temperature-dependent experimental measurements were used to calibrate the modeling parameters and to validate the model prediction.« less

  16. Engaging Stakeholders in Patient-Centered Outcomes Research Regarding School-Based Sealant Programs.

    PubMed

    Chi, Donald L; Milgrom, Peter; Gillette, Jane

    2018-02-01

    Purpose: The purpose of this study was to use qualitative methods to describe the key lessons learned during the stakeholder engagement stage of planning a randomized clinical trial comparing outcomes of silver diamine fluoride (SDF) as an alternative to pit-and-fissure sealants in a school-based delivery system. Methods: Eighteen caregivers and community-based stakeholders with involvement in the school-based sealant program Sealants for Smiles from the state of Montana, were recruited for this qualitative study. United States (U.S.) Patient-Centered Outcomes Research Institute (PCORI) methodology standards were used to develop two semi-structured interview guides consisting of 6 questions. One interview guide was used for telephone interviews with caregivers and the second was used for a stakeholder focus group. Content analytic methods were used to analyze the data. Results: All participants believed that a study comparing SDF and sealants was clinically relevant. Non-caregiver stakeholders agreed with the proposed primary outcome of the study (caries prevention) whereas caregivers also emphasized the importance of child-centered outcomes such as minimizing dental anxiety associated with dental care. Stakeholders described potential concerns associated with SDF such as staining and perceptions of safety and discussed ways to address these concerns through community engagement, appropriate framing of the study, proper consent procedures, and ongoing safety monitoring during the trial. Finally, stakeholders suggested dissemination strategies such as direct communication of findings through professional organizations and encouraging insurance plans to incentivize SDF use by reimbursing dental providers. Conclusions: Involving key stakeholders in early planning is essential in developing patient-centered research questions, outcomes measures, study protocols, and dissemination plans for oral health research involving a school-based delivery system. Copyright © 2018 The American Dental Hygienists’ Association.

  17. Evaluation of different types of enamel conditioning before application of a fissure sealant.

    PubMed

    Ciucchi, Philip; Neuhaus, Klaus W; Emerich, Marta; Peutzfeldt, Anne; Lussi, Adrian

    2015-01-01

    The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.

  18. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation

    PubMed Central

    Fortelny, René H.; Petter-Puchner, Alexander H.; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Results: Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Conclusion: Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair. PMID:25593969

  19. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    PubMed

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  20. A reversible thermoresponsive sealant for temporary closure of ocular trauma.

    PubMed

    Bayat, Niki; Zhang, Yi; Falabella, Paulo; Menefee, Roby; Whalen, John J; Humayun, Mark S; Thompson, Mark E

    2017-12-06

    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N -isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  1. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    PubMed

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  2. A new heterologous fibrin sealant as a scaffold to cartilage repair—Experimental study and preliminary results

    PubMed Central

    de Barros, Caio Nunes; Miluzzi Yamada, Ana Lúcia; Junior, Rui Seabra F; Barraviera, Benedito; Hussni, Carlos Alberto; de Souza, Jaqueline Brandão; Watanabe, Marcos Jun; Rodrigues, Celso Antônio

    2015-01-01

    Autologous fibrin gel is commonly used as a scaffold for filling defects in articular cartilage. This biomaterial can also be used as a sealant to control small hemorrhages and is especially helpful in situations where tissue reparation capacity is limited. In particular, fibrin can act as a scaffold for various cell types because it can accommodate cell migration, differentiation, and proliferation. Despite knowledge of the advantages of this biomaterial and mastery of the techniques required for its application, the durability of several types of sealant at the site of injury remains questionable. Due to the importance of such data for evaluating the quality and efficiency of fibrin gel formulations on its use as a scaffold, this study sought to analyze the heterologous fibrin sealant developed from the venom of Crotalus durissus terrificus using studies in ovine experimental models. The fibrin gel developed from the venom of this snake was shown to act as a safe, stable, and durable scaffold for up to seven days, without causing adverse side effects. Fibrin gel produced from the venom of the Crotalus durissus terrificus snake possesses many clinical and surgical uses. It presents the potential to be used as a biomaterial to help repair skin lesions or control bleeding, and it may also be used as a scaffold when applied together with various cell types. The intralesional use of the fibrin gel from the venom of this snake may improve surgical and clinical treatments in addition to being inexpensive and adequately consistent, durable, and stable. The new heterologous fibrin sealant is a scaffold candidate to cartilage repair in this study. PMID:26264444

  3. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    PubMed

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  4. A Tale of Two Citizens: A State Attorney General and a Hematologist Facilitate Translation of Research Into US Food and Drug Administration Actions—A SONAR Report

    PubMed Central

    Chen, Brian; Restaino, John; Norris, LeAnn; Xirasagar, Sudha; Qureshi, Zaina P.; McKoy, June M.; Lopez, Isaac S.; Trenery, Alyssa; Murday, Alanna; Kahn, Adam; Mattison, Donald R.; Ray, Paul; Sartor, Oliver; Bennett, Charles L.

    2012-01-01

    Purpose: Pharmaceutical safety is a public health issue. In 2005, the Connecticut Attorney General (AG) raised concerns over adverse drug reactions in off-label settings, noting that thalidomide was approved to treat a rare illness, but more than 90% of its use was off label. A hematologist had reported thalidomide with doxorubicin or dexamethasone was associated with venous thromboembolism (VTE) rates of 25%. We review US Food and Drug Administration (FDA) and manufacturer responses to a citizen petition filed to address these thalidomide safety issues. Methods: Case study. Results: The AG petitioned the FDA requesting thalidomide-related safety actions. Coincidentally, the manufacturer submitted a supplemental New Drug Approval (sNDA), requesting approval to treat multiple myeloma with thalidomide-dexamethasone. FDA safety officers reviewed the petition and the literature and noted that VTE risks with thalidomide were not appropriately addressed in the existing package insert. In the sNDA application, the manufacturer reported thalidomide-associated toxicities for multiple myeloma were primarily somnolence and neurotoxicity, and a proposed package insert did not focus on VTE risks. In October, the FDA informed the Oncology Drug Division that VTE risks with thalidomide were poorly addressed in the existing label. After reviewing this memorandum, an Oncology Drug Division reviewer informed the manufacturer that approval of the sNDA would be delayed until several thalidomide-associated VTE safety actions, including revisions of the package insert, were implemented. The manufacturer and FDA agreed on these actions, and the sNDA was approved. Conclusion: New approaches addressing off-label safety are needed. The conditions that facilitated the successful response to this citizen petition are uncommon. PMID:23598851

  5. A tale of two citizens: a State Attorney General and a hematologist facilitate translation of research into US Food and Drug Administration actions--a SONAR report.

    PubMed

    Chen, Brian; Restaino, John; Norris, LeAnn; Xirasagar, Sudha; Qureshi, Zaina P; McKoy, June M; Lopez, Isaac S; Trenery, Alyssa; Murday, Alanna; Kahn, Adam; Mattison, Donald R; Ray, Paul; Sartor, Oliver; Bennett, Charles L

    2012-11-01

    Pharmaceutical safety is a public health issue. In 2005, the Connecticut Attorney General (AG) raised concerns over adverse drug reactions in off-label settings, noting that thalidomide was approved to treat a rare illness, but more than 90% of its use was off label. A hematologist had reported thalidomide with doxorubicin or dexamethasone was associated with venous thromboembolism (VTE) rates of 25%. We review US Food and Drug Administration (FDA) and manufacturer responses to a citizen petition filed to address these thalidomide safety issues. Case study. The AG petitioned the FDA requesting thalidomide-related safety actions. Coincidentally, the manufacturer submitted a supplemental New Drug Approval (sNDA), requesting approval to treat multiple myeloma with thalidomide-dexamethasone. FDA safety officers reviewed the petition and the literature and noted that VTE risks with thalidomide were not appropriately addressed in the existing package insert. In the sNDA application, the manufacturer reported thalidomide-associated toxicities for multiple myeloma were primarily somnolence and neurotoxicity, and a proposed package insert did not focus on VTE risks. In October, the FDA informed the Oncology Drug Division that VTE risks with thalidomide were poorly addressed in the existing label. After reviewing this memorandum, an Oncology Drug Division reviewer informed the manufacturer that approval of the sNDA would be delayed until several thalidomide-associated VTE safety actions, including revisions of the package insert, were implemented. The manufacturer and FDA agreed on these actions, and the sNDA was approved. New approaches addressing off-label safety are needed. The conditions that facilitated the successful response to this citizen petition are uncommon.

  6. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    PubMed

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  7. Comparison of short-term in vitro fluoride release and recharge from four different types of pit-and-fissure sealants.

    PubMed

    Koga, Hiroshi; Kameyama, Atsushi; Matsukubo, Takashi; Hirai, Yoshito; Takaesu, Yoshinori

    2004-08-01

    The purpose of this in vitro study was to assess the effects of four commercial fluoride-containing pit-and-fissure sealants on caries prevention. Four sealants containing fluoride, Fuji III, Fuji III LC (GC Co., Tokyo), Teethmate F-1 (Kuraray Medical Co., Osaka) and Helioseal F (Vivadent Co., Liechtenstein) were used to investigate fluoride release and recharge. Disk-shaped specimens prepared from each material were immersed in distilled water at a temperature of 37 degrees C. After seven days, acidulated phosphate fluoride solution (APF) was applied to each specimen, and it was then again immersed in distilled water for 14 days. We then determined how much fluoride had been released into the immersing water. Fuji III LC was used with APF solution to investigate the fluoride uptake. Fuji III had the highest fluoride release, and Fuji III LC had the highest fluoride recharge. Helioseal F and Teethmate F-1 had almost no fluoride recharge. Fuji III LC/APF had a higher fluoride uptake to enamel than Fuji III LC. These results suggest that GIC-sealants in the oral cavity can serve as a fluoride reservoir and contribute to retaining a low fluoride level in oral fluids, thereby preventing caries.

  8. An analysis of pipe flange connections using epoxy adhesives/anaerobic sealant instead of gaskets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sawa, T.; Sasaki, R.; Yoneno, M.

    1995-11-01

    This paper deals with the strength and the sealing performance of pipe flange connections combining the bonding force of adhesives with the clamping force of bolts. The epoxy adhesives or anaerobic sealants are bonded at the interface partially instead of gaskets in pipe flange connections. The stress distribution in the epoxy adhesives (anaerobic sealant), which governs the sealing performance, and the variations in axial bolt force are analyzed, using an axisymmetrical theory of elasticity, when an internal pressure is applied to a connection in which two pipe flanges are clamped together buy bolts and nuts with an initial clamping forcemore » after being joined by epoxy adhesives or anaerobic sealant. In addition, a method for estimating the strength of the combination connection is demonstrated. Experiments are performed and the analytical results are consistent with the experimental results concerning the variation in axial bolt force and the strength of combination connections. It can be seen that the strength of connections increases with a decrease in the bolt pitch circle diameter. Furthermore, it is seen that the sealing performance of such combination connections in which the interface is bonded partially is improved over that of pipe flange connections with metallic gaskets.« less

  9. Changes in Caries Experience, Untreated Caries, Sealant Prevalence, and Preventive Behavior Among Third-Graders in New York State, 2002-2004 and 2009-2012.

    PubMed

    Kumar, Jayanth V; Tavares, Vinicius; Kandhari, Priyanka; Moss, Mark; Jolaoso, I Adeyemi

    2015-01-01

    This study assessed changes in caries experience, untreated caries, sealant prevalence, and preventive behavior among third-grade children in New York State to monitor progress toward state health objectives. We analyzed children's data from the 2002-2004 (n=10,865) and 2009-2012 (n=6,758) New York State Oral Health Survey. We calculated differences in weighted percentages and 95% confidence intervals for caries experience, untreated caries, sealant prevalence, and preventive behavior. We used logistic regression procedures to assess the independent effects and interaction terms on dental caries experience. The percentage of children with dental caries and untreated caries decreased from 54.1% and 33.0% in 2002-2004 to 45.2% and 23.6% in 2009-2012, respectively. While this decrease was not uniform across income subgroups, the prevalence of sealants, a key measure of the use of preventive services, increased significantly from 16.7% to 36.0% among lower-income children. Measurable improvement in reducing dental caries prevalence among third-grade children has been made in New York State, but this improvement was not uniform across subgroups. Specifically, disease prevalence among lower-income children remained high, underscoring the need to strengthen existing programs and identify additional policy and programmatic interventions.

  10. Collagen sealant patch to reduce lymphatic drainage after lymph node dissection.

    PubMed

    Di Monta, Gianluca; Caracò, Corrado; Crispo, Anna; Marone, Ugo; Mozzillo, Nicola

    2012-12-19

    Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy.

  11. Collagen sealant patch to reduce lymphatic drainage after lymph node dissection

    PubMed Central

    2012-01-01

    Background Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. Methods This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. Results A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Conclusions Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy. PMID:23253298

  12. [Distal Pancreatectomy with Autologous Fibrin Sealant - Implementation of an Established Concept of Tissue Sealing in Pancreatic Surgery].

    PubMed

    Luu, A M; Braumann, C; Belyaev, O; Janot, M; Uhl, W; Herzog, T

    2016-12-01

    Background: Postoperative pancreatic fistulas (POPF) remain a major concern after distal pancreatectomy. Irrespective of the technique to close the pancreatic remnant, pancreatic fistulas will occur in approximately 30 % of patients undergoing distal pancreatectomy. For the first time ever, autologous fibrin sealant (Vivostat®) was used to additionally seal the pancreatic remnant after a distal pancreatectomy. The aim was to analyse whether this changes the postoperative outcome. Patients/Material and Methods: In 2015, a technical case series was performed in 15 patients who underwent distal pancreatectomy. The pancreatic remnant was additionally sealed with autologous fibrin sealant (Vivostat®). Results: A postoperative pancreatic fistula (POPF) occurred in 5/15 patients (33 %). One patient had a POPF grade A (1/15, 6.7 %), whereas a POPF grade B occurred in 4/15 patients (26.7 %). 75 % (3/4) of the patients with a POPF grade B were sufficiently treated with antibiotics, whereas a CT-guided percutaneous drainage had to be placed only in one case. Conclusion: Autologous fibrin sealant is simple to apply and seems to be well tolerated. However, it does not seem to avoid the development of postoperative pancreatic fistulas after distal pancreatectomy. Georg Thieme Verlag KG Stuttgart · New York.

  13. A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study.

    PubMed

    Fujiwara, Yasuhiro; Fujioka, Hitoshi; Watanabe, Tomoko; Sekiguchi, Maiko; Murakami, Ryuji

    2017-09-01

    Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.

  14. Women's preferences for vaginal antimicrobial contraceptives. III. Choice of a formulation, applicator, and packaging.

    PubMed

    Hardy, E; Jiménez, A L; de Pádua, K S; Zaneveld, L J

    1998-10-01

    Novel vaginal formulations are under development to combat the increasing incidence of sexually transmitted diseases, including AIDS, and also unplanned pregnancies. A study was performed to determine women's preferences for different dosage forms (gel, cream, ovule/suppository, film, foam, tablet), width, length, and color of an applicator, and various types of packages. The study was conducted in Campinas, Brazil. A total of 635 women were interviewed, including both adolescents and adults and low and middle-high socioeconomic groups. The large majority of the women preferred a gel over a cream; both were preferred over the other methods. When asked which method they would not use, the film was most frequently identified, followed by the tablet and ovule. The primary reasons for selecting a particular dosage form were ease of use, absence of odor or the presence of a pleasant one, absence of color, and insertion with an applicator. The major reasons for not using a method were discomfort, "plastic" appearance, distrust of effectiveness, difficulty with insertion, messiness, and rigidity/hardness. The majority of the women liked the applicator shown. The prefilled single dose applicator was by far the preferred packaging. This information should aid in the development of consumer-friendly, vaginal formulations.

  15. Three-Dimensional Printing of Bisphenol A-Free Polycarbonates.

    PubMed

    Zhu, Wei; Pyo, Sang-Hyun; Wang, Pengrui; You, Shangting; Yu, Claire; Alido, Jeffrey; Liu, Justin; Leong, Yew; Chen, Shaochen

    2018-02-14

    Polycarbonates are widely used in food packages, drink bottles, and various healthcare products such as dental sealants and tooth coatings. However, bisphenol A (BPA) and phosgene used in the production of commercial polycarbonates pose major concerns to public health safety. Here, we report a green pathway to prepare BPA-free polycarbonates (BFPs) by thermal ring-opening polymerization and photopolymerization. Polycarbonates prepared from two cyclic carbonates in different mole ratios demonstrated tunable mechanical stiffness, excellent thermal stability, and high optical transparency. Three-dimensional (3D) printing of the new BFPs was demonstrated using a two-photon laser direct writing system and a rapid 3D optical projection printer to produce structures possessing complex high-resolution geometries. Seeded C3H10T1/2 cells also showed over 95% viability with potential applications in biological studies. By combining biocompatible BFPs with 3D printing, novel safe and high-performance biomedical devices and healthcare products could be developed with broad long-term benefits to society.

  16. Public judgments of information in a diazepam patient package insert.

    PubMed

    Fisher, S; Mansbridge, B; Lankford, D A

    1982-06-01

    As part of a larger study of the effects of giving patients written take-home information with prescription medications, a "patient package insert" (PPI) for diazepam was prepared based on content determined by "experts." This report compares the experts' judgments of what information should be included with judgments obtained from the public. Information judged to be most important for inclusion in a PPI was identified by having subjects sort cards containing facts about diazepam. Subjects who had previously used diazepam were no different in their judgments than inexperienced subjects. In general, there was a high degree of concordance between public and expert judgments and also a remarkably strong consensus across very different demographic samples. In those few instances of disagreement, the public attached even greater importance to warnings and "bad news" about diazepam than to information providing reassurances, benign general education, and "good news." To what extent patients would effectively use this information--whether conveyed by PPIs or alternative educational routes--must await empirical evaluation.

  17. Device-packaging method and apparatus for optoelectronic circuits

    DOEpatents

    Zortman, William A.; Henry, Michael David; Jarecki, Jr., Robert L.

    2017-04-25

    An optoelectronic device package and a method for its fabrication are provided. The device package includes a lid die and an active die that is sealed or sealable to the lid die and in which one or more optical waveguides are integrally defined. The active die includes one or more active device regions, i.e. integral optoelectronic devices or etched cavities for placement of discrete optoelectronic devices. Optical waveguides terminate at active device regions so that they can be coupled to them. Slots are defined in peripheral parts of the active dies. At least some of the slots are aligned with the ends of integral optical waveguides so that optical fibers or optoelectronic devices inserted in the slots can optically couple to the waveguides.

  18. Fuzzy based attitude controller for flexible spacecraft with on/off thrusters. M.S. Thesis - M.I.T., 1993

    NASA Technical Reports Server (NTRS)

    Knapp, Roger Glenn

    1993-01-01

    A fuzzy-based attitude controller is designed for attitude control of a generic spacecraft with on/off thrusters. The controller is comprised of packages of rules dedicated to addressing different objectives (e.g., disturbance rejection, low fuel consumption, avoiding the excitation of flexible appendages, etc.). These rule packages can be inserted or removed depending on the requirements of the particular spacecraft and are parameterized based on vehicle parameters such as inertia or operational parameters such as the maneuvering rate. Individual rule packages can be 'weighted' relative to each other to emphasize the importance of one objective relative to another. Finally, the fuzzy controller and rule packages are demonstrated using the high-fidelity Space Shuttle Interactive On-Orbit Simulator (IOS) while performing typical on-orbit operations and are subsequently compared with the existing shuttle flight control system performance.

  19. High temperature seal compositions and methods of using same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solberg, Scott Eugene

    The disclosure relates to sealant compositions for forming hermetic seals, methods of use, and hermetically sealed products. The sealant compositions comprise a first inorganic oxide chosen from at least one of MgSiO.sub.3, MgO, MgTiO.sub.3, CaO, and CaSiO.sub.3, a second inorganic oxide chosen from SiO.sub.2, at least one solvent, and optionally at least one organic resin binder.

  20. [Comparative studies on fissure sealing: composite versus Cermet cement].

    PubMed

    Hickel, R; Voss, A

    1989-06-01

    Fifty two molars sealed with either composite or Cermet cement were compared. The composite sealant was applied after enamel etching using a rubber dam. Before sealing with Cermet cement the enamel was only cleaned with pumice powder and sodium hypochlorie and the material was applied without enamel etching. After an average follow-up of 1.6 years composite sealants proved to be significantly more reliable. Cermet cement sealings showed defects more frequently.

  1. Cryogenic adhesives and sealants: Abstracted publications

    NASA Technical Reports Server (NTRS)

    Williamson, F. R.; Olien, N. A.

    1977-01-01

    Abstracts of primary documents containing original experimental data on the properties of adhesives and sealants at cryogenic temperatures are presented. The most important references mentioned in each document are cited. In addition, a brief annotation is given for documents considered secondary in nature, such as republications or variations of original reports, progress reports leading to final reports included as primary documents, and experimental data on adhesive properties at temperatures between about 130 K and room temperature.

  2. Development of a Novel Alginate-Based Pleural Sealant

    DTIC Science & Technology

    2017-09-01

    and will be the subject of ongoing studies . Figure 20: Experimental set-up for endobronchial administration of sealants in the ex vivo pig lung...toxicity. In the studies to date, we have done extensive materials characterization not just of modified alginates but now a number of other biologic...pig) ex vivo lung models and have performed initial in vivo evaluations of several compounds in a non-survival surgery rat lung injury model. The

  3. VACUUM SEALING MEANS FOR LOW VACUUM PRESSURES

    DOEpatents

    Milleron, N.

    1962-06-12

    S>A vacuum seal is designed in which the surface tension of a thin layer of liquid metal of low vapor pressure cooperates with adjacent surfaces to preclude passages of gases across pressure differentials as low as 10/sup -8/ mm Hg. Mating contiguous surfaces composed of copper, brass, stainless steel, nickel, molybdenum, tungsten, tantalum, glass, quartz, and/or synthetic mica are disposed to provide a maximum tolerance, D, expressed by 2 gamma /P/sub 1/, where gamma is the coefflcient of the surface tension of the metal sealant selected in dynes/cm/sub 2/. Means for heating the surfaces remotely is provided where temperatures drop below about 250 deg C. A sealant consisting of an alloy of gallium, indium, and tin, among other combinations tabulated, is disposed therebetween after treating the surfaces to improve wettability, as by ultrasonic vibrations, the surfaces and sealants being selected according to the anticipated experimental conditions of use. (AEC)

  4. Integral gas seal for fuel cell gas distribution assemblies and method of fabrication

    DOEpatents

    Dettling, Charles J.; Terry, Peter L.

    1985-03-19

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  5. Method of fabricating an integral gas seal for fuel cell gas distribution assemblies

    DOEpatents

    Dettling, Charles J.; Terry, Peter L.

    1988-03-22

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  6. Fibrin chain cross-linking, fibrinolysis, and in vivo sealing efficacy of differently structured fibrin sealants.

    PubMed

    Hedrich, Hans Christian; Simunek, Manuela; Reisinger, Sonja; Ferguson, James; Gulle, Heinz; Goppelt, Andreas; Redl, Heinz

    2012-08-01

    In this study, we compared the sealing characteristics and efficacy of a fibrin sealant with reduced plasminogen (FS-rplg) and a fibrin sealant with aprotinin as a fibrinolysis inhibitor (FS-apr). The relevant sealing characteristics including clot structure, fibrin chain cross-linking, and clot lysis were tested in the laboratory. The sealing efficacy was then investigated in a follow-up animal model to determine differences in the in vivo sealing properties. A total of 46 animals were available for the final analysis with 23 animals in each treatment arm. In conclusion, we saw differences in vitro between FS-rplg and FS-apr in ultrastructure and α-chain cross-linking rates as well as in the rate of fibrinolysis. These differences may explain the significantly enhanced sealing efficacy in FS-apr compared to FS-rplg shown in vivo in a rabbit intestinal model. Copyright © 2012 Wiley Periodicals, Inc.

  7. Effect of sealant agents on the color stability and surface roughness of nanohybrid composite resins.

    PubMed

    Dede, Doğu Ömür; Şahin, Onur; Koroglu, Aysegül; Yilmaz, Burak

    2016-07-01

    The effect of sealant agents on the surface roughness and color stability of nanohybrid composite resins is unknown. The purpose of this in vitro study was to evaluate the effect of sealant agents on the surface roughness and color stability of 4 nanohybrid composite resin materials. Forty disks (10×2 mm) were fabricated for each nanohybrid composite resin material (Z-550, Tetric EvoCeram, Clearfill Majesty, Ice) (N=160) and divided into 4 surface treatment groups: 1 conventional polishing (control) and 3 different sealant agent (Palaseal, Optiglaze, BisCover) coupling groups (n=10). The specimens were thermocycled, and surface roughness (Ra) values were obtained with a profilometer. Scanning electron microscope images were also recorded. CIELab color parameters of each specimen were measured with a spectrophotometer before and after 7 days of storage in a coffee solution. Color differences were calculated by the CIEDE 2000 (ΔE00) formula. The data were statistically analyzed by 2-way ANOVA and by the Tukey HSD test (α=.05). The surface treatment technique significantly affected the Ra values of the composite resins tested (P<.001). The interaction between the surface treatment technique and composite resin material was also significant for ΔE00 values (P<.05). Within the composite resin groups, significant decreases in Ra were observed only for the Palaseal agent coupled composite resin groups (except Ice) compared with the control groups (P<.05). Scanning electron microscope images revealed rougher surfaces with conventionally polished groups compared with test groups. Conventionally polished groups had the highest ΔE00 (3.09 to 3.49) values for each composite resin group, except for BisCover applied Clearfill Majesty (P<.05). Within the composite resin groups, significant differences were observed between the color change seen with BisCover and other sealants for Clearfill Majesty composite resin (P<.05). Using Palaseal agent on all tested composite resins except for Ice produced smoother surfaces. All surface sealant agents provided less discoloration of nanohybrid composite resins after coffee staining compared with conventional polishing except for BisCover applied Clearfill Majesty composite resin. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Intracellular Distribution of Capsid-Associated pUL77 of Human Cytomegalovirus and Interactions with Packaging Proteins and pUL93.

    PubMed

    Köppen-Rung, Pánja; Dittmer, Alexandra; Bogner, Elke

    2016-07-01

    DNA packaging into procapsids is a common multistep process during viral maturation in herpesviruses. In human cytomegalovirus (HCMV), the proteins involved in this process are terminase subunits pUL56 and pUL89, which are responsible for site-specific cleavage and insertion of the DNA into the procapsid via portal protein pUL104. However, additional viral proteins are required for the DNA packaging process. We have shown previously that the plasmid that encodes capsid-associated pUL77 encodes another potential player during capsid maturation. Pulse-chase experiments revealed that pUL77 is stably expressed during HCMV infection. Time course analysis demonstrated that pUL77 is expressed in the early late part of the infectious cycle. The sequence of pUL77 was analyzed to find nuclear localization sequences (NLSs), revealing monopartite NLSm at the N terminus and bipartite NLSb in the middle of pUL77. The potential NLSs were inserted into plasmid pHM829, which encodes a chimeric protein with β-galactosidase and green fluorescent protein. In contrast to pUL56, neither NLSm nor NLSb was sufficient for nuclear import. Furthermore, we investigated by coimmunoprecipitation whether packaging proteins, as well as pUL93, the homologue protein of herpes simplex virus 1 pUL17, are interaction partners of pUL77. The interactions between pUL77 and packaging proteins, as well as pUL93, were verified. We showed that the capsid-associated pUL77 is another potential player during capsid maturation of HCMV. Protein UL77 (pUL77) is a conserved core protein of HCMV. This study demonstrates for the first time that pUL77 has early-late expression kinetics during the infectious cycle and an intrinsic potential for nuclear translocation. According to its proposed functions in stabilization of the capsid and anchoring of the encapsidated DNA during packaging, interaction with further DNA packaging proteins is required. We identified physical interactions with terminase subunits pUL56 and pUL89 and another postulated packaging protein, pUL93, in infected, as well as transfected, cells. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  9. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of.... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert...

  10. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  11. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  12. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  13. 22 CFR 125.6 - Certification requirements for exemptions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Certifications consist of clearly marking the package or letter containing the technical data “22 CFR [insert... LICENSES FOR THE EXPORT OF TECHNICAL DATA AND CLASSIFIED DEFENSE ARTICLES § 125.6 Certification requirements for exemptions. (a) To claim an exemption for the export of technical data under the provisions of...

  14. Canister, Sealing Method And Composition For Sealing A Borehole

    DOEpatents

    Brown, Donald W.; Wagh, Arun S.

    2005-06-28

    Method and composition for sealing a borehole. A chemically bonded phosphate ceramic sealant for sealing, stabilizing, or plugging boreholes is prepared by combining an oxide or hydroxide and a phosphate with water to form slurry. The slurry is introduced into the borehole where the seal, stabilization or plug is desired, and then allowed to set up to form the high strength, minimally porous sealant, which binds strongly to itself and to underground formations, steel and ceramics.

  15. Effect of Temperature on the Storage Life of Polysulfide Sealants

    DTIC Science & Technology

    1989-01-01

    University of Adelaide, South Australia. After two and a half years of experience in Rubber Technology with the Olympic Tyre and Rubber Company, Melbourne...he joined the rubber section of MRL in November 1970. Since 1975 he has been involved in R & D work in the sealant section as an Experimental Officer...repeatedly passing the mixture through a triple roll mill. One set of the calcium carbonate-solvent series was enclosed in a heat sealed wrapping of

  16. Pit and Fissure Sealants in Young Adults: An Evaluation of Placement Time and Retention Rate Using Two Isolation Techniques.

    DTIC Science & Technology

    1983-01-01

    retention by dental arch and method of isol..tion at twelve months ................................ 45 TABLE XVI Seven month inter-examiner reliability data...specific protection against the occurrence and progression of a specific disease, namely dental caries. The American Dental Association endorses the use...years. Yet many unanswered questions remain concerning the use of sealants. Only 15% of dental practitioners report that they routinely use them (4

  17. Thermally resistant polymers for fuel tank sealants

    NASA Technical Reports Server (NTRS)

    Webster, J. A.

    1973-01-01

    Imide-linked perfluoroalkylene ether polymers, that were developed for the high temperature fuel tank sealant application, are discussed. Modifications of polymer structure and properties were realized through use of a new aromatic dianhydride intermediate containing an ether-linked perfluoroalkylene segment. Tests of thermal, oxidative and hydrolytic stability, fuel resistance, and adhesion are discussed along with tensile strength and elongation results. Efforts to effect a low temperature condensation of amic acid prepolymer to form imide links inside are described.

  18. Parents' Attitude towards the Use of Fluorides and Fissure Sealants and its Effect on their Children's Oral Health.

    PubMed

    Blumer, Sigalit; Ratson, Tal; Peretz, Benjamin; Dagon, Nurit

    To characterize the attitudes of Israeli parents towards caries preventive measures. participating parents completed a 21-item questionnaire on their demographics, dental history, attitudes and satisfaction from fluorides and fissure sealants. One hundred parents (average age 41.62±4.9 years, 85 females) participated. Most of the parents (88% of the mothers and 84% of the fathers) had an academic education. Most of the parents (54%) had a favorable attitude towards the use of fluoridated gels, while only 37% of them had a positive opinion regarding fluoridated water. The satisfaction levels were very high regarding fissure sealants, fluoridated mouth rinses and fluoridated gels (78.1%, 73.6% and 72.5% respectively). The satisfaction from fluoridated water was split almost equally (50.8% were 'pleased' and 49.2% 'not pleased'). The main source for parental oral health knowledge was the dentist (83%). Parents' attitude towards caries preventive measures was significantly correlated to their gender, dental experience, level of education and the number of children in the family. positive attitude towards caries preventive measures was found among parents with higher awareness for preventive oral health measures and among bigger families. Mothers were more positive about fissure sealants than fathers. Mothers with up to 12 years of education tended to have a positive opinion regarding water fluoridation.

  19. Direct Spinal Ventral Root Repair following Avulsion: Effectiveness of a New Heterologous Fibrin Sealant on Motoneuron Survival and Regeneration

    PubMed Central

    Barbizan, Roberta; Seabra Ferreira, Rui

    2016-01-01

    Axonal injuries at the interface between central and peripheral nervous system, such as ventral root avulsion (VRA), induce important degenerative processes, mostly resulting in neuronal and motor function loss. In the present work, we have compared two different fibrin sealants, one derived from human blood and another derived from animal blood and Crotalus durissus terrificus venom, as a promising treatment for this type of injury. Lewis rats were submitted to VRA (L4–L6) and had the avulsed roots reimplanted to the surface of the spinal cord, with the aid of fibrin sealant. The spinal cords were processed to evaluate neuronal survival, synaptic stability, and glial reactivity, 4 and 12 weeks after lesion. Sciatic nerves were processed to investigate Schwann cell activity by p75NTR expression (4 weeks after surgery) and to count myelinated axons and morphometric evaluation (12 weeks after surgery). Walking track test was used to evaluate gait recovery, up to 12 weeks. The results indicate that both fibrin sealants are similarly efficient. However, the snake-derived fibrin glue is a potentially safer alternative for being a biological and biodegradable product which does not contain human blood derivatives. Therefore, the venom glue can be a useful tool for the scientific community due to its advantages and variety of applications. PMID:27642524

  20. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children

    PubMed Central

    Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    Objective To compare three variants of a culturally-relevant and theoretically-based message to determine the most influential risk framing approach for improving intention to place dental sealants for preschool children. Design and Sample A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. Measurements We compared participant's scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. Results The mean difference in participant's stage-of-change scores (x = 1.17, n = 89, sd = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t(88) = 5.81, p < .0001, 95% CI [0.77 – 1.57]. Self-efficacy was the only construct for which we detected a statistically significant difference as a function of frame assignment. Overall, the mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Conclusions Community advisory board members determined to use the mix-framed approach in an oral-health social marketing campaign with a rural, American Indian audience. PMID:26032902

  1. Multiple lead seal assembly for a liquid-metal-cooled fast-breeder nuclear reactor

    DOEpatents

    Hutter, Ernest; Pardini, John A.

    1977-03-15

    A reusable multiple lead seal assembly provides leak-free passage of stainless-steel-clad instrument leads through the cover on the primary tank of a liquid-metal-cooled fast-breeder nuclear reactor. The seal isolates radioactive argon cover gas and sodium vapor within the primary tank from the exterior atmosphere and permits reuse of the assembly and the stainless-steel-clad instrument leads. Leads are placed in flutes in a seal body, and a seal shell is then placed around the seal body. Circumferential channels in the body and inner surface of the shell are contiguous and together form a conduit which intersects each of the flutes, placing them in communication with a port through the wall of the seal shell. Liquid silicone rubber sealant is injected into the flutes through the port and conduit; the sealant fills the space in the flutes not occupied by the leads themselves and dries to a rubbery hardness. A nut, threaded onto a portion of the seal body not covered by the seal shell, jacks the body out of the shell and shears the sealant without damage to the body, shell, or leads. The leads may then be removed from the body. The sheared sealant is cleaned from the body, leads, and shell and the assembly may then be reused with the same or different leads.

  2. A comparative study of fissure sealants Helioseal Clear Chroma and Delton FS(+): 3 year results.

    PubMed

    Kargul, B; Tanboga, I; Gulman, N

    2009-12-01

    To evaluate the retention rates of a resin based colour changing fissure sealant (Helioseal Clear Chroma; Ivoclar Vivadent AG Schaan, Liechtenstein) compared with a coloured resin based fluoride fissure sealant (Delton FS(+); Dentsply De Trey GmbH,Konstanz,Germany). The fissure sealants (FS) were placed on all 4 caries-free first permanent molars of 31 children aged 6-9 years, using a half mouth experimental design by a paediatric dentist according to the manufacturers' instructions. A total of 121 FS were placed at baseline. Teeth were evaluated at 3 month intervals for 36 months where a preventive program including topical fluoride application was applied. Retention rates for 36 months showed a differences between Delton FS(+) and Helioseal Clear Chroma that were statistically significant (p<0.05). Delton FS(+) had total retention rate of 30.4% for 36 months compared with Helioseal Clear Chroma at 10.8% for the same evaluation period. Although Delton FS(+) showed significantly better results than Helioseal Clear Chroma for the evaluation periods, there were no statistically significant differences between Delton FS(+) (90.7%) and Helioseal Clear Chroma (80.4%) with respect to caries incidence at 36 months(p>0.05). Delton FS(+) showed a better complete retention rate for occlusal FS at one year. Both FS were aesthetically acceptable and easy to see during application and follow-up periods and gave significant protection from occlusal decay.

  3. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children.

    PubMed

    Larsson, Laura S; Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    To compare three variants of a culturally relevant and theoretically based message to determine the most influential risk-framing approach for improving intention to place dental sealants for preschool children. A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. We compared participants' scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. The mean difference in participants' stage-of-change scores (x = 1.17, n = 89, SD = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t88  = 5.81, p < .0001, 95% CI [0.77-1.57]. Self-efficacy was the only construct for which we detected a statistically significant difference as a function of frame assignment. Overall, the mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Community advisory board members determined to use the mix-framed approach in an oral health social marketing campaign with a rural, American Indian audience. © 2015 Wiley Periodicals, Inc.

  4. A randomized prospective multicenter trial of a novel vascular sealant.

    PubMed

    Stone, William M; Cull, David L; Money, Samuel R

    2012-11-01

    Increasing use of anticoagulant medications, particularly antiplatelet therapies, can increase the difficulty in obtaining adequate suture line hemostasis. Multiple vascular sealants have been used as adjuncts to surgical procedures, but none of them have been universally successful. The aim of this study was to evaluate the safety and effectiveness of a new prophylactic vascular sealant in arterial surgery. A randomized prospective multi-institutional trial was undertaken comparing ArterX Vascular Sealant (AVS) with Gelfoam Plus during open arterial reconstruction. Three hundred thirty-one anastomotic sites in 217 patients were randomized. One hundred one of 167 (60.5%) anastomotic sites in the AVS group achieved immediate hemostasis compared with 65 of 164 (39.6%) in the control group (P = 0.001). In anastomoses with polytetrafluoroethylene grafts, 105 of 167 (62.5%) in the AVS group achieved immediate hemostasis compared with 56 of 164 (34.0%) in the control group (P < 0.001). No significant differences were noted in morbidity or mortality. Operative time was significantly less in the AVS group compared with the control group (3.2 vs. 3.8 hours, P < 0.01). Use of AVS results in superior hemostatic effectiveness compared with Gelfoam Plus, with no difference in safety. Although no cost analysis was performed, cost savings likely resulted from significantly decreased operative time. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  5. An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology.

    PubMed

    O' Callaghan, Karen A M; Papkovsky, Dmitri B; Kerry, Joseph P

    2016-06-20

    The establishment and control of oxygen levels in packs of oxygen-sensitive food products such as cheese is imperative in order to maintain product quality over a determined shelf life. Oxygen sensors quantify oxygen concentrations within packaging using a reversible optical measurement process, and this non-destructive nature ensures the entire supply chain can be monitored and can assist in pinpointing negative issues pertaining to product packaging. This study was carried out in a commercial cheese packaging plant and involved the insertion of 768 sensors into 384 flow-wrapped cheese packs (two sensors per pack) that were flushed with 100% carbon dioxide prior to sealing. The cheese blocks were randomly assigned to two different storage groups to assess the effects of package quality, packaging process efficiency, and handling and distribution on package containment. Results demonstrated that oxygen levels increased in both experimental groups examined over the 30-day assessment period. The group subjected to a simulated industrial distribution route and handling procedures of commercial retailed cheese exhibited the highest level of oxygen detected on every day examined and experienced the highest rate of package failure. The study concluded that fluctuating storage conditions, product movement associated with distribution activities, and the possible presence of cheese-derived contaminants such as calcium lactate crystals were chief contributors to package failure.

  6. An Assessment of the Influence of the Industry Distribution Chain on the Oxygen Levels in Commercial Modified Atmosphere Packaged Cheddar Cheese Using Non-Destructive Oxygen Sensor Technology

    PubMed Central

    O’ Callaghan, Karen A.M.; Papkovsky, Dmitri B.; Kerry, Joseph P.

    2016-01-01

    The establishment and control of oxygen levels in packs of oxygen-sensitive food products such as cheese is imperative in order to maintain product quality over a determined shelf life. Oxygen sensors quantify oxygen concentrations within packaging using a reversible optical measurement process, and this non-destructive nature ensures the entire supply chain can be monitored and can assist in pinpointing negative issues pertaining to product packaging. This study was carried out in a commercial cheese packaging plant and involved the insertion of 768 sensors into 384 flow-wrapped cheese packs (two sensors per pack) that were flushed with 100% carbon dioxide prior to sealing. The cheese blocks were randomly assigned to two different storage groups to assess the effects of package quality, packaging process efficiency, and handling and distribution on package containment. Results demonstrated that oxygen levels increased in both experimental groups examined over the 30-day assessment period. The group subjected to a simulated industrial distribution route and handling procedures of commercial retailed cheese exhibited the highest level of oxygen detected on every day examined and experienced the highest rate of package failure. The study concluded that fluctuating storage conditions, product movement associated with distribution activities, and the possible presence of cheese-derived contaminants such as calcium lactate crystals were chief contributors to package failure. PMID:27331815

  7. Optimization of La 2O 3-containing diopside based glass-ceramic sealants for fuel cell applications

    NASA Astrophysics Data System (ADS)

    Goel, Ashutosh; Tulyaganov, Dilshat U.; Kharton, Vladislav V.; Yaremchenko, Aleksey A.; Eriksson, Sten; Ferreira, José M. F.

    We report on the optimization of La 2O 3-containing diopside based glass-ceramics (GCs) for sealant applications in solid oxide fuel cells (SOFC). Seven glass compositions were prepared by modifying the parent glass composition, Ca 0.8Ba 0.1MgAl 0.1La 0.1Si 1.9O 6. First five glasses were prepared by the addition of different amounts of B 2O 3 in a systematic manner (i.e. 2, 5, 10, 15, 20 wt.%) to the parent glass composition while the remaining two glasses were derived by substituting SrO for BaO in the glasses containing 2 wt.% and 5 wt.% B 2O 3. Structural and thermal behavior of the glasses was investigated by infrared spectroscopy (FTIR), density measurements, dilatometry and differential thermal analysis (DTA). Liquid-liquid amorphous phase separation was observed in B 2O 3-containing glasses. Sintering and crystallization behavior, microstructure, and properties of the GCs were investigated under different heat treatment conditions (800 and 850 °C; 1-300 h). The GCs with ≥5 wt.% B 2O 3 showed an abnormal thermal expansion behavior above 600 °C. The chemical interaction behavior of the glasses with SOFC electrolyte and metallic interconnects, has been investigated in air atmosphere at SOFC operating temperature. Thermal shock resistance and gas-tightness of GC sealants in contact with 8YSZ was evaluated in air and water. The total electrical resistance of a model cell comprising Crofer 22 APU and 8YSZ plates joined by a GC sealant has been examined by the impedance spectroscopy. Good matching of thermal expansion coefficients (CTE) and strong, but not reactive, adhesion to electrolyte and interconnect, in conjunction with a low level of electrical conductivity, indicate that the investigated GCs are suitable candidates for further experimentation as SOFC sealants.

  8. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    PubMed Central

    Pithon, Matheus Melo; Santos, Mariana de Jesus; de Souza, Camilla Andrade; Leão, Jorge César Borges; Braz, Ana Karla Souza; de Araujo, Renato Evangelista; Tanaka, Orlando Motohiro; Oliveira, Dauro Douglas

    2015-01-01

    Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15) according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control), only brushing was performed with 1.450 ppm fluoride; G2 (control) brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT) of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded) and depth measurement of carious lesions were performed. Analysis of variance (ANOVA) was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003), 1 and 3 (p = 0.008), 1 and 4 (p = 0.000) and 1 and 5 (p = 0.000). The group in which only brushing was performed (Group 1) showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone. PMID:26691968

  9. A comparison of the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts after calving in cows also given internal teat sealants.

    PubMed

    Whitfield, L K; Laven, R A

    2018-01-01

    To compare, in cows treated with an internal teat sealant, the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts (SCC) after calving. Cows from a spring-calving, pasture-based dairy farm in the Manawatu-Whanganui region of New Zealand were randomly allocated to receive either a short-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=291) or a long-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=288) at the end of lactation. Cows were managed on-farm with routine husbandry procedures through the dry period and following calving. A multivariable logistic regression model was used to determine the association between length of action of dry-cow therapy and the proportion of cows with a SCC >150,000 cells/mL at the first herd test after calving. Age of cow, mean SCC for the preceding season and interval from calving to the first post-calving herd test were all associated with the proportion of cows with an individual SCC >150,000 cells/mL at the first herd test (p<0.001) Treatment with the short-acting dry-cow therapy was not associated with decreased odds of cows having a SCC >150,000 cells/mL at the first herd test compared with treatment with long-acting dry-cow therapy (OR=0.724; 95% CI=0.40-1.30). In this herd, which routinely used internal teat sealants, the use of short-acting cloxacillin-based dry-cow therapy did not result in an increased proportion of cows with elevated SSC post-calving. This was a single farm, single year study but indicates that in this herd, changing from a long-acting to a short-acting antimicrobial may have no impact on the prevalence of subclinical mastitis.

  10. High-Tc superconductor coplanar waveguide filter

    NASA Technical Reports Server (NTRS)

    Chew, Wilbert; Bajuk, Louis J.; Cooley, Thomas W.; Foote, Marc C.; Hunt, Brian D.; Rascoe, Daniel L.; Riley, A. L.

    1991-01-01

    Coplanar waveguide (CPW) low-pass filters made of YBa2Cu3O(7-delta) (YBCO) on LaAlO3 substrates, with dimensions suited for integrated circuits, were fabricated and packaged. A complete filter gives a true idea of the advantages and difficulties in replacing thin-film metal with a high-temperature superconductor in a practical circuit. Measured insertion losses in liquid nitrogen were superior to the loss of a similar thin-film copper filter throughout the 0- to 9.5-GHz passband. These results demonstrate the performance of fully patterned YBCO in a practical CPW structure after sealing in a hermetic package.

  11. Apparatus and Method for Packaging and Integrating Microphotonic Devices

    NASA Technical Reports Server (NTRS)

    Nguyen, Hung (Inventor)

    2008-01-01

    An apparatus is disclosed that includes a carrier structure and an optical coupling arrangement. The carrier structure is made of a silicon material and allows for the packaging and integrating of microphotonic devices onto a single chip. The optical coupling mechanism enables laser light to be coupled into and out of a microphotonic resonant disk integrated on the carrier. The carrier provides first, second and third cavities that are dimensioned so as to accommodate the insertion and snug fitting of the microphotonic resonant disk and first and second prisms that are implemented by the optical coupling arrangement to accommodate the laser coupling.

  12. Agony of the ecstasy: report of five cases of MDMA smuggling.

    PubMed

    Low, V H S; Dillon, E K

    2005-10-01

    The international smuggling of illicit drugs by the ingestion or rectal insertion of drug-filled packages is recognized in the trafficking of heroin and cocaine. Customs authorities, with suspicion of such activities, presented five subjects. The legally allowed radiological examination comprising one supine abdominal radiograph was performed. Radiographic findings demonstrated the presence of multiple enteric oval, capsule-shaped packages of soft tissue density. This was confirmed following supervised evacuation of bowel contents induced by the administration of laxatives. Analysis of the concealed material identified ecstasy (methylenedioxymethamphetamine (MDMA)), a substance not previously reported as transported by this route.

  13. Interactions between F-111 Fuselage Fuel Tank Sealants. Part 2. Variation in Performance Properties of Polysulfides after Contact with Polyester Degradation Products,

    DTIC Science & Technology

    1984-08-01

    principally from sebacic acid and neopentyl glycol and that the most significant difference between the sealants was the greater proportion of trihydric...exhaustive hydrolysis of the polyesters would generate sebacic acid and neopentyl glycol , in practice ester units such as (1) which are terminated with both...slight to moderate swelling and softening of the polysulfides with PR-1422 being the most susceptible. Neopentyl glycol suppressed the swelling due to

  14. Nonsurgical management of an enlarging pneumatocele by fibrin sealant injection via pigtail catheter.

    PubMed

    Park, Tae Hyun; Kim, Jin Kyu

    2016-02-01

    Most pneumatoceles disappear spontaneously and do not cause severe symptoms. Treatment alternatives include various conventional or surgical methods. However, an enlarging, complicated pneumatocele with cardiorespiratory instability requires imaging-guided catheter drainage or surgery. Here, we report the case of a newborn girl with an enlarging pneumatocele accompanied by pulmonary interstitial emphysema secondary to mechanical ventilation. The pneumatocele was successfully managed by the injection of fibrin sealant via a pigtail catheter. © 2015 Wiley Periodicals, Inc.

  15. Biomimetic, Strong, Tough, and Self-Healing Composites Using Universal Sealant-Loaded, Porous Building Blocks.

    PubMed

    Hwang, Sung Hoon; Miller, Joseph B; Shahsavari, Rouzbeh

    2017-10-25

    Many natural materials, such as nacre and dentin, exhibit multifunctional mechanical properties via structural interplay between compliant and stiff constituents arranged in a particular architecture. Herein, we present, for the first time, the bottom-up synthesis and design of strong, tough, and self-healing composite using simple but universal spherical building blocks. Our composite system is composed of calcium silicate porous nanoparticles with unprecedented monodispersity over particle size, particle shape, and pore size, which facilitate effective loading and unloading with organic sealants, resulting in 258% and 307% increases in the indentation hardness and elastic modulus of the compacted composite. Furthermore, heating the damaged composite triggers the controlled release of the nanoconfined sealant into the surrounding area, enabling moderate recovery in strength and toughness. This work paves the path towards fabricating a novel class of biomimetic composites using low-cost spherical building blocks, potentially impacting bone-tissue engineering, insulation, refractory and constructions materials, and ceramic matrix composites.

  16. Nondestructive spectroscopic characterization of building materials

    NASA Astrophysics Data System (ADS)

    Kassu, Aschalew; Walker, Lauren; Sanders, Rachel; Farley, Carlton; Mills, Jonathan; Sharma, Anup

    2017-04-01

    The purpose of this research project is to demonstrate the application of Raman spectroscopy technique for characterization and identification of the distinct Raman signatures of construction materials. The results reported include the spectroscopic characterization of building materials using compact Raman system with 785 nm wavelength laser. The construction materials studied include polyblend sanded grout, fire barrier sealant, acrylic latex caulk plus and white silicone. It is found that, both fire barrier sealant and acrylic latex caulk plus has a prominent Raman band at 1082 cm-1, and three minor Raman signatures located at 275, 706 and 1436 cm-1. On the other hand, sand grout has three major Raman bands at 1265, 1368 and 1455 cm-1, and four minor peaks at 1573, 1683, 1762, and 1868 cm-1. White silicone, which is a widely used sealant material in construction industry, has two major Raman bands at 482 and 703 cm-1, and minor Raman characteristic bands at 783 and 1409 cm-1.

  17. The immediate and long-term effects of invasive and noninvasive pit and fissure sealing techniques on the microflora in occlusal fissures of human teeth.

    PubMed

    Kramer, P F; Zelante, F; Simionato, M R

    1993-01-01

    The purpose of this study was to evaluate the effect of acid conditioning and occlusal sealant on microbial colonization of pit and fissures submitted to ameloplasty or left intact. Human enamel blocks containing fissures prepared from the occlusal surfaces of unerupted third molars were implanted in occlusal fillings in molars of 12 patients for seven, 30, 60, and 120 days. After seven days of exposure to the oral environment, the pit and fissure blocks were removed and found to be colonized, mainly with gram-positive coccal flora. The acid-etching procedure itself reduced the number of cultivable microorganisms by about 95%. Subsequent application of occlusal sealant caused a gradual decrease of the remaining viable microorganism throughout the experiment. Despite the decrease of 100% after acid etching in most of the fissures submitted to ameloplasty, the occlusal sealant did not lead to a subsequent significant reduction.

  18. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  19. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  20. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  1. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  2. 21 CFR 357.152 - Package inserts for anthelmintic drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... discussion of the symptoms suggestive of pinworm infestation, including a statement that pinworms must be... the pinworm. (c) A commentary on the life cycle of the pinworm. (d) A commentary on the ways in which pinworms may be spread from person to person and hygienic procedures to follow to avoid such spreading. (e...

  3. Isolating USB connections in medical equipment.

    PubMed

    Broeders, Jan-Hein

    2009-01-01

    Although offering several benefits, the universal serial bus (USB) port has not been rapidly adopted for connecting medical equipment. This is because it could affect safety procedures, with equipment not operating isolated from the mains. To overcome this, a single package isolation device has been developed that can be inserted directly into the USB signal path.

  4. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    NASA Astrophysics Data System (ADS)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  5. [Safety profile of heterologous serum produced by the Butantan Institute, in São Paulo-SP, Brazil, from 2012 to 2015].

    PubMed

    Gattás, Vera Lúcia; Braga, Patrícia Emília; Koike, Marcelo Eiji; Lucchesi, Maria Beatriz; Precioso, Alexander Roberto

    2017-01-01

    to describe the safety profile of the heterologous serum produced by the Butantan Institute (BI) of São Paulo-SP, Brazil. a descriptive study of adverse events (AEs) post-exposure to serum produced by the BI, encoded in the medical terminology of the Medical Dictionary for Regulatory Activities (MedDRA), and spontaneously reported to BI from 2012 to 2015. 52 individuals reported AEs, mainly related to Bothrops antivenom (n=11), diphtheria antitoxin (n=9) and unspecified snakebite serum (n=9); a mean of 3.2 AEs per individual was observed; among the total of 173 AEs, 63.0% were expected considering that they were described in the package insert; most of them were classified as skin and subcutaneous tissue disorders (30.6%); there were six deaths temporally related to the use of serum, but this association was discarded. in the studied period, the serum produced by the BI had no changes in their safety profiles, considering that the AEs were expected, according to the information previously described in the package insert.

  6. The modified Ottawa method to establish the update need of a systematic review: glass-ionomer versus resin sealants for caries prevention

    PubMed Central

    MICKENAUTSCH, Steffen; YENGOPAL, Veerasamy

    2013-01-01

    Objective To demonstrate the application of the modified Ottawa method by establishing the update need of a systematic review with focus on the caries preventive effect of GIC versus resin pit and fissure sealants; to answer the question as to whether the existing conclusions of this systematic review are still current; to establish whether a new update of this systematic review was needed. Methods: Application of the Modified Ottawa method. Application date: April/May 2012. Results Four signals aligned with the criteria of the modified Ottawa method were identified. The content of these signals suggest that higher precision of the current systematic review results might be achieved if an update of the current review were conducted at this point in time. However, these signals further indicate that such systematic review update, despite its higher precision, would only confirm the existing review conclusion that no statistically significant difference exists in the caries-preventive effect of GIC and resin-based fissure sealants. Conclusion In conclusion, this study demonstrated the modified Ottawa method as an effective tool in establishing the update need of the systematic review. In addition, it was established that the conclusions of the systematic review in relation to the caries preventive effect of GIC versus resin based fissure sealants are still current, and that no update of this systematic review was warranted at date of application. PMID:24212996

  7. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant.

    PubMed

    Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; Estrada-Aguilar, María del Carmen; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro

    2010-06-14

    To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 +/- 14.2 d and 32.5 +/- 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 +/- 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 +/- 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas.

  8. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement

    USGS Publications Warehouse

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH8) in the 0.03-m samples above sealed lots (1320 ng m-3) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m-3). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m-3) was five times greater than above unsealed lots (26.0 ng m-3). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m-2 h-1, respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces.

  9. Atraumatic restorative treatment and minimal intervention dentistry.

    PubMed

    Frencken, J E

    2017-08-11

    Too many people worldwide suffer from the consequences of untreated dentine carious lesions. This finding reflects the inability of the currently used traditional mode of treatments to manage such lesions. A change is needed. Dental training institutions should depart from the traditional 'drill and fill' treatments and embrace the holistic oral healthcare approach that is minimal intervention dentistry (MID) and includes within it minimally invasive operative skills. Dental caries is, after all, a preventable disease. The atraumatic restorative treatment (ART) concept is an example of MID. ART consists of a preventive (ART sealant) and a restorative (ART restoration) component. ART sealants using high-viscosity glass-ionomer (HVGIC) have a very high dentine carious lesion preventive effect. The survival rate of these sealants is not significantly different from that of sealants produced with resin. The survival rate of ART/HVGIC restorations matches those of amalgam and resin composite in single- and multiple-surface cavities in primary teeth and in single-surface cavities in permanent teeth. The principles of carious tissue removal within a cavity recommended by the International Caries Consensus Collaboration are in line with those of treating a cavity using ART. Owing to its good performance and the low levels of discomfort/pain and dental anxiety associated with it, ART and/or other evidence-based atraumatic care procedures should be the first treatment for a primary dentine carious lesion. Only if the use of ART is not indicated should other more invasive and less-atraumatic care procedures be used in both primary and permanent dentitions.

  10. The use of a 'bleach-etch-seal' deproteinization technique on MIH affected enamel.

    PubMed

    Gandhi, Shan; Crawford, Peter; Shellis, Peter

    2012-11-01

    To ascertain whether deproteinization pretreatment of molar-incisor hypomineralization (MIH) enamel affects resin sealant infiltration. Thirty one extracted MIH teeth were divided into three sections and randomly allocated into the Control (etch and FS), Treatment 1 (5% NaOCl, etched and fissure sealed), and Treatment 2 (5% NaOCl and fissure sealed with no etch) groups. Two hundred seventy nine sealant tag/enamel grade observations were recorded by scanning electron microscopy. Control and Treatment 1 were similar in their outcomes, and Treatment 2 was markedly different. There was no statistical evidence to suggest that there was any difference between Treatment 1 and the Control Treatment (95% CI, 0.52, 1.51; P = 0.6). There was a marked difference between Treatment 2 and the Control Treatment (95% CI, 0.07, 0.25; P < 0.001). All treatments also demonstrated a high-predicted probability of obtaining 'poor' sealant tags (Control = 47%, Treatment 1 = 49%, and Treatment 2 = 40%). The findings suggest that there was no significant difference in the tag quality between the conventional technique (Control) and the 'bleach-etch-seal' technique (Treatment 1). There was no benefit in pre-treating with NaOCl alone (without etch) before sealing. This research also showed that there was a high-predicted probability of obtaining 'poor' sealant tags in MIH enamel, regardless of which of the three treatments was used. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  11. Compliant sealants for solid oxide fuel cells and other ceramics

    DOEpatents

    Bloom, I.D.; Ley, K.L.

    1995-09-26

    A glass or glass-ceramic sealant is described for a SOFC having a coefficient of thermal expansion in the range of from about 8 to about 13{times}10{sup {minus}6}/C and a viscosity of at least 10{sup 3}Pa-s at cell operating temperature. The sealant has a composition of SrO present in the range of from about 5 to about 60 mole percent, La{sub 2}O{sub 3} present in the range of from 0 to about 45 mole percent, Al{sub 2}O{sub 3} present in the range from 0 to about 15 mole percent, B{sub 2}O{sub 3} present in the range of from about 15 mole percent to about 80 mole percent, and SiO{sub 2} present in the range of from 0 to about 40 mole percent, wherein the material is a viscous fluid at cell operating temperatures of from about 600 C to about 1000 C. The sealant may also be compounds of CaO present in the range of from 0 to about 35 mole percent, Al{sub 2}O{sub 3} present in the range from 0 to about 15 mole percent, B{sub 2}O{sub 3} present in the range of from about 35 mole percent to about 85 mole percent, and SiO{sub 2} present in the range of from 0 to about 30 mole percent. 2 figs.

  12. Randomized pilot study to disseminate caries-control services in dentist offices

    PubMed Central

    Grembowski, David; Spiekerman, Charles; del Aguila, Michael A; Anderson, Maxwell; Reynolds, Debra; Ellersick, Allison; Foster, James; Choate, Leslie

    2006-01-01

    Background To determine whether education and financial incentives increased dentists' delivery of fluoride varnish and sealants to at risk children covered by capitation dental insurance in Washington state (U.S.). Methods In 1999, 53 dental offices in Washington Dental Service's capitation dental plan were invited to participate in the study, and consenting offices were randomized to intervention (n = 9) and control (n = 10) groups. Offices recruited 689 capitation children aged 6–14 and at risk for caries, who were followed for 2 years. Intervention offices received provider education and fee-for-service reimbursement for delivering fluoride varnish and sealants. Insurance records were used to calculate office service rates for fluoride, sealants, and restorations. Parents completed mail surveys after follow-up to measure their children's dental utilization, dental satisfaction, dental fear and oral health status. Regression models estimated differences in service rates between intervention and control offices, and compared survey measures between groups. Results Nineteen offices (34%) consented to participate in the study. Fluoride and sealant rates were greater in the intervention offices than the control offices, but the differences were not statistically significant. Restoration rates were lower in the intervention offices than the control offices. Parents in the intervention group reported their children had less dental fear than control group parents. Conclusion Due to low dentist participation the study lacked power to detect an intervention effect on dentists' delivery of caries-control services. The intervention may have reduced children's dental fear. PMID:16670027

  13. Compliant sealants for solid oxide fuel cells and other ceramics

    DOEpatents

    Bloom, Ira D.; Ley, Kevin L.

    1995-01-01

    A glass or glass-ceramic sealant for a SOFC having a coefficient of thermal expansion in the range of from about 8 to about 13.times.10.sup.-6 /.degree.C. and a viscosity of at least 10.sup.3 Pa-s at cell operating temperature. The sealant has a composition of SrO present in the range of from about 5 to about 60 mole percent, La.sub.2 O.sub.3 present in the range of from 0 to about 45 mole percent, Al.sub.2 O.sub.3 present in the range from 0 to about 15 mole percent, B.sub.2 O.sub.3 present in the range of from about 15 mole percent to about 80 mole percent, and SiO.sub.2 present in the range of from 0 to about 40 mole percent, wherein the material is a viscous fluid at cell operating temperatures of from about 600.degree. C. to about 1000.degree. C. The sealant may also be compounds of CaO present in the range of from 0 to about 35 mole percent, Al.sub.2 O.sub.3 present in the range from 0 to about 15 mole percent, B.sub.2 O.sub.3 present in the range of from about 35 mole percent to about 85 mole percent, and SiO.sub.2 present in the range of from 0 to about 30 mole percent.

  14. Wear of two pit and fissure sealants in contact with primary teeth

    PubMed Central

    Galo, Rodrigo; Contente, Marta Maria Martins Giamatei; Borsatto, Maria Cristina

    2014-01-01

    Objectives: Wear simulations may provide an indication of the clinical performance of pit-and-fissure sealants when associated with primary teeth as counterbody, restricting the involved variables. The aim of this study was to evaluate wear of dental materials used as pit-and-fissure sealants in contact with primary teeth. Materials and Methods: A resinous sealant (Fluroshield®) and a resin-modified glass ionomer cement (Vitremer®) were selected in a post-plate design, using as counterbody primary tooth pins (4 × 4 × 2 mm) at 3 and 10 N vertical load, 1 Hz frequency, 900 wear cycles in artificial saliva (n = 15). Attrition coefficient values were obtained and the material and primary tooth volumes were analyzed. Data were analyzed statistically by ANOVA and Duncan's test (P < 0.05). Results: Fluroshield® presented the highest attrition coefficient values for the 3 N but these values decreased significantly for the 10 N load. The means for volume loss (3 mm) of the different samples after the wear test were not statistically different for the materials. The volume loss values for the primary teeth were statistically different and there was an increase in volume loss with the increase of the load applied in the wear tests. Conclusions: Differences were also observed with regard to the surface deformation characteristics. The wear rates of primary tooth enamel vary according to the type of material and the load applied during mastication. PMID:24966777

  15. An in vitro study of fibrin sealant as a carrier system for recombinant human bone morphogenetic protein (rhBMP)-9 for bone tissue engineering.

    PubMed

    Fujioka-Kobayashi, Masako; Mottini, Matthias; Kobayashi, Eizaburo; Zhang, Yufeng; Schaller, Benoit; Miron, Richard J

    2017-01-01

    In the craniofacial bone field, fibrin sealants are used as coagulant and adhesive tools to stabilize grafts during surgery. Despite this, their exact role in osteogenesis is poorly characterized. In the present study, we aimed to characterize the osteogenic potential of TISSEEL fibrin sealant and used its technology to incorporate growth factors within its matrix. We focused on recombinant human bone morphogenetic protein (rhBMP)-9, which has previously been characterized as one of the strongest osteogenetic inducers in the BMP family. TISSEEL displayed an excellent ability to retain rhBMP9, which was gradually released over a 10-day period. Although TISSEEL decreased bone stromal ST2 cell attachment at 8 h, it displayed normal cell proliferation at 1, 3, and 5 days when compared to tissue culture plastic. Interestingly, TISSEEL had little influence on osteoblast differentiation; however its combination with rhBMP9 significantly increased ALP activity at 7 days, Alizarin Red staining at 14 days, and mRNA levels of osteoblast differentiation markers ALP, bone sialoprotein, and osteocalcin. In summary, although fibrin sealants were shown to have little influence on osteogenesis, their combination with bone-inducing growth factors such as rhBMP9 may serve as an attractive carrier/scaffold for future bone regenerative strategies. Future animal studies are now necessary. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement.

    PubMed

    Van Metre, Peter C; Majewski, Michael S; Mahler, Barbara J; Foreman, William T; Braun, Christopher L; Wilson, Jennifer T; Burbank, Teresa L

    2012-06-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH(8)) in the 0.03-m samples above sealed lots (1320 ng m(-3)) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m(-3)). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m(-3)) was five times greater than above unsealed lots (26.0 ng m(-3)). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m(-2) h(-1), respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces. Published by Elsevier Ltd.

  17. Blood leak alarm interference by hydoxocobalamin is hemodialysis machine dependent.

    PubMed

    Sutter, M E; Clarke, M E; Cobb, J; Daubert, G P; Rathore, V S; Aston, L S; Poppenga, R H; Ford, J B; Owen, K P; Albertson, T E

    2012-12-01

    Hydroxocobalamin has been reported to interfere with the blood leak alarm on hemodialysis machines making it difficult to use this treatment modality after hydroxocobalamin infusion. The objective was to determine if this interference with hydroxocobalamin occurs across hemodialysis machines by different manufacturers. Additionally, we aimed to see if this represented a colorimetric interference alone or if it is the optical properties of hydroxocobalamin. Hydroxocobalamin was reconstituted per package insert. Food coloring was added to 0.9% saline to create the colors of the visual spectrum. Optical properties of absorbance and transmittance were measured. Hydroxocobalamin and the saline solutions were infused into the Fresenius 2008K™ and the Gambro Phoenix X36™ machines. Times were recorded from the start of the machine until the solution finished or the alarm triggered. When evaluating the Gambro Phoenix X36™ machine and dialysis circuit; the alarm did not trigger. In contrast, the blood leak alarm on the Fresenius 2008K™ machine was tripped by both the red solution and hydoxocobalamin infused per the package insert. The alarm stopped the machine between 128 and 132 seconds for the red solution and between 30 and 35 seconds with the hydroxocobalamin. Membranes of the circuits where the alarm tripped were examined and remained intact without blood. Results were validated on different machines with new circuits. Hydroxocobalamin infusion per package insert and the red saline solution prepared with Red Dye 40 both triggered the blood leak alarm and stopped the Fresenius 2008K™ machine. However, this was not true for the Gambro Phoenix X36™ machine as the alarm never triggered. The interference with the Fresenius 2008K™ appears colorimetric due to normal saline with Red Dye 40 triggering the alarm. We alert physicians to become familiar with the properties of individual dialysis machines prior to use of hydroxocobalamin. When facing difficulties with hemodialysis after the administration of hydroxocobalamin, consider attempting with a different manufactures machine or model if available or contact the manufacturer directly.

  18. Use of a hydrogel sealant in epithelial ingrowth removal after laser in situ keratomileusis.

    PubMed

    Ramsook, Sandhya S; Hersh, Peter S

    2015-12-01

    We describe 2 cases in which clinically significant epithelial ingrowth was removed by debridement and followed by the use of a hydrogel sealant (Resure) to seal the flap edge. In both cases, the epithelial ingrowth was seen after otherwise uneventful laser in situ keratomileusis retreatment. The visual outcomes were good with no recrudescence of interface epithelium. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Transabdominal preperitoneal herniorrhaphy using laser-assisted tissue soldering in a porcine model.

    PubMed

    Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45micro, 4.5W CW, 5mm spot, and 55 degrees C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

  20. Virus-Like Particles Derived from HIV-1 for Delivery of Nuclear Proteins: Improvement of Production and Activity by Protein Engineering.

    PubMed

    Robert, Marc-André; Lytvyn, Viktoria; Deforet, Francis; Gilbert, Rénald; Gaillet, Bruno

    2017-01-01

    Virus-like particles (VLPs) derived from retroviruses and lentiviruses can be used to deliver recombinant proteins without the fear of causing insertional mutagenesis to the host cell genome. In this study we evaluate the potential of an inducible lentiviral vector packaging cell line for VLP production. The Gag gene from HIV-1 was fused to a gene encoding a selected protein and it was transfected into the packaging cells. Three proteins served as model: the green fluorescent protein and two transcription factors-the cumate transactivator (cTA) of the inducible CR5 promoter and the human Krüppel-like factor 4 (KLF4). The sizes of the VLPs were 120-150 nm in diameter and they were resistant to freeze/thaw cycles. Protein delivery by the VLPs reached up to 100% efficacy in human cells and was well tolerated. Gag-cTA triggered up to 1100-fold gene activation of the reporter gene in comparison to the negative control. Protein engineering was required to detect Gag-KLF4 activity. Thus, insertion of the VP16 transactivation domain increased the activity of the VLPs by eightfold. An additional 2.4-fold enhancement was obtained by inserting nuclear export signal. In conclusion, our platform produced VLPs capable of efficient protein transfer, and it was shown that protein engineering can be used to improve the activity of the delivered proteins as well as VLP production.

  1. Prospective clinical evaluation of the Polyperf® Safe, a safety Huber needle, in cancer patients.

    PubMed

    Goossens, Godelieve A; Moons, Philip; Jérôme, Martine; Stas, Marguerite

    2011-01-01

    Evaluation of the Polyperf® Safe (PPS) needle on safety and user-friendliness, as experienced by first-time and non-first-time users of the device. A prospective, descriptive study was carried out at the University Hospitals Leuven, Belgium. Five hundred PPS needles were individually evaluated in cancer patients. Different aspects of the PPS were assessed: packaging, needle insertion, and needle removal. Nurses were asked whether they had previously inserted or removed this type of needle. We compared the PPS needle with the standard Gripper® needle in terms of safety, ease of use, and ease of training. Three hundred sixty-six evaluation forms were available for analysis (73.2%). Packaging and access evaluations were scored positively, except for two aspects: (1) needle stability, and (2) ease of dressing. Ease of removal was scored unsatisfactory in up to 22.4% of the registrations. Pain at insertion was reported in about 20% registrations, and blood contact was reported by 2.5% of non-first-time users. Safety was scored as good, although ease of use and ease in training scored 25.4% and 43.8%, respectively, lower than the Gripper®. In general, nurses evaluated the PPS positively, with the exception of needle stability, ease of dressing, and ease of removal. No needlestick accidents were recorded. Aspects of ease of use and ease of training for PPS needles scored less than those for the Gripper® needles in up to one-third of the registrations.

  2. 78 FR 63226 - GlaxoSmithKline LLC; Withdrawal of Approval of the Indication for Treatment of Patients With...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... have not received prior rituximab, for BEXXAR (tositumomab and iodine I 131 tositumomab) Injection held... withdraw the rituximab-na[iuml]ve indication for BEXXAR (tositumomab and iodine I 131 tositumomab... indication for BEXXAR (tositumomab and iodine I 131 tositumomab) Injection from the package insert. In the...

  3. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  4. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  5. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  6. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  7. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... used in total parenteral nutrition. 201.323 Section 201.323 Food and Drugs FOOD AND DRUG ADMINISTRATION... parenteral nutrition. (a) The aluminum content of large volume parenteral (LVP) drug products used in total parenteral nutrition (TPN) therapy must not exceed 25 micrograms per liter (µg/L). (b) The package insert of...

  8. GSFC Cutting Edge Avionics Technologies for Spacecraft

    NASA Technical Reports Server (NTRS)

    Luers, Philip J.; Culver, Harry L.; Plante, Jeannette

    1998-01-01

    With the launch of NASA's first fiber optic bus on SAMPEX in 1992, GSFC has ushered in an era of new technology development and insertion into flight programs. Predating such programs the Lewis and Clark missions and the New Millenium Program, GSFC has spearheaded the drive to use cutting edge technologies on spacecraft for three reasons: to enable next generation Space and Earth Science, to shorten spacecraft development schedules, and to reduce the cost of NASA missions. The technologies developed have addressed three focus areas: standard interface components, high performance processing, and high-density packaging techniques enabling lower cost systems. To realize the benefits of standard interface components GSFC has developed and utilized radiation hardened/tolerant devices such as PCI target ASICs, Parallel Fiber Optic Data Bus terminals, MIL-STD-1773 and AS1773 transceivers, and Essential Services Node. High performance processing has been the focus of the Mongoose I and Mongoose V rad-hard 32-bit processor programs as well as the SMEX-Lite Computation Hub. High-density packaging techniques have resulted in 3-D stack DRAM packages and Chip-On-Board processes. Lower cost systems have been demonstrated by judiciously using all of our technology developments to enable "plug and play" scalable architectures. The paper will present a survey of development and insertion experiences for the above technologies, as well as future plans to enable more "better, faster, cheaper" spacecraft. Details of ongoing GSFC programs such as Ultra-Low Power electronics, Rad-Hard FPGAs, PCI master ASICs, and Next Generation Mongoose processors.

  9. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing.

    PubMed

    Gomes-Silva, Jaciara Miranda; Torres, Carolina Paes; Contente, Marta Maria Martins Giamatei; Oliveira, Maria Angélica Hueb de Menezes; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2008-01-01

    This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

  10. Maryland dental hygienists' knowledge, opinions and practices regarding dental caries prevention and early detection.

    PubMed

    Clovis, Joanne B; Horowitz, Alice M; Kleinman, Dushanka V; Wang, Min Qi; Massey, Meredith

    2012-01-01

    The purpose of this study was to assess Maryland dental hygienists' knowledge, practices and opinions regarding dental caries prevention and early detection. A 30 item survey was mailed to 1,258 Maryland dental hygienists. Two follow-up mailings and email reminders were sent. The response rate was 43% (n=540). Nearly all respondents were female (98%), and 58% practiced in solo settings. Knowledge and certainty of knowledge were moderate: sealants are needed regardless of topical fluoride use (55% certain, 40% less certain), newly erupted permanent molars are the best candidates for sealants (54%, 36%) and professionally applied fluorides are desirable in areas without fluoridated water (55%, 36%). Fewer were certain that incipient lesions can be remineralized before cavitation (23%, 69%), and dilute, frequently administered fluorides are more effective in caries prevention than concentrated, less frequently administered fluorides (6%, 24%). Opinions regarding effectiveness of protocols for 2 age groups from 6 months to 6 years, the challenges of early childhood caries (ECC), prevention practices regarding sealant and topical fluoride applications varied widely. Eighty-nine percent reported routinely assessing dental caries risk factors of child patients and 90% were interested in continuing education courses. There were no significant differences between different types of practice settings, year of graduation, race/ethnicity or gender. Knowledge of recommended guidelines for fluoride and sealant application support clinical decision-making and self-care counseling. Misinformation and lack of understanding of current research and recommendations identify a need for educational interventions in undergraduate dental hygiene programs and through continuing education for practicing hygienists.

  11. Noninvasive pit and fissure sealing: microtensile bond strength to intact bovine enamel of different pit and fissure sealants in a simplified fissure model.

    PubMed

    Papacchini, Federica; Cury, Alvaro H; Goracci, Cecilia; Chieffi, Nicoletta; Tay, Franklin R; Polimeni, Antonella; Ferrari, Marco

    2006-12-01

    To measure the microtensile bond strength of different pit and fissure sealants in a simplified fissure model. Twenty extracted bovine mandibular permanent incisors were randomly divided into 4 groups for treatment: G1: 35% phosphoric acid/Clinpro Sealant; G2: 35% phosphoric acid/Delton; G3: Non-Rinse Conditioner/Dyract Seal; G4: 20% polyacrylic acid/Fuji IILC. Each tooth was sectioned into 6 pieces (4 x 6 mm) of buccal enamel. SEM examination was used to confirm the presence of aprismatic enamel on each tooth. Using a spacer, two pieces of etched enamel were secured to a glass slide at a mean distance of 0.6+/-0.1 mm. The space between enamel substrates was then etched/conditioned and sealed with different materials according to the tested groups. By serially cutting each double-bonded sample, multiple beam-shaped specimens about 0.8mm(2) in cross section were obtained and tested in tension (0.5 mm/min) until failure occurred at either one of the two stressed interfaces. Failure modes were classified by stereomicroscopy. G1 and G2 showed statistically higher bond strengths than G3 and G4. G4 demonstrated the significantly lowest bond strength. Failures were mostly adhesive in G1, G2, G3, and mainly cohesive/mixed in G4. According to this model, resin-based materials (Clinpro Sealant, Delton) showed better microtensile bond strength than compomer (Dyract Seal) or resin-modified glass ionomer (Fuji IILC).

  12. Controlling air leaks using free pericardial fat pads as surgical sealant in pulmonary resection.

    PubMed

    Ikeda, Takeshi; Sasaki, Masato; Yamada, Narihisa; Takamori, Atsushi; Tanabe, Sawaka; Okada, Akitoshi; Sakon, Kayo; Mizunaga, Tae; Koshiji, Takaaki

    2015-04-01

    This study evaluated the feasibility and efficacy of a new operative method for controlling intraoperative air leaks using free pericardial fat pads as a covering sealant in pulmonary resection. To manage air leaks that must be controlled in pulmonary resection at the first water sealing test, collected free pericardial fat was used as a covering sealant and sewn on by the suture closing the lesion. In cases of uncontrolled air leaks at the second sealing test, fibrin glue was used to fill the residual lesion between the fat and visceral pleura. Fifty-one eligible patients were enrolled in this study to evaluate the duration of postoperative air leaks and the condition of the implanted fat on chest computed tomography (CT) 6 months later. The mean duration of postoperative air leaks was 1.05 ± 1.84 days in the 39 cases that received the pericardial fat covering technique only and 2.66 ± 3.42 days in the 12 cases that received the pericardial fat covering technique combined with fibrin glue. Prolonged alveolar air leaks occurred in 1 case and 2 cases, respectively. No cases required conversion to conventional methods, and there were no further adverse events. On follow-up chest CT approximately 62.7% of obvious engrafted fat survived. Using free pericardial fat pads as a sealant to control air leaks in pulmonary resection is safe and has good feasibility and potent efficacy. This new method can be an innovative technique for preventing prolonged air leaks. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Fissure sealant materials: Wear resistance of flowable composite resins.

    PubMed

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  14. Fissure sealant materials: Wear resistance of flowable composite resins

    PubMed Central

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics. PMID:27651887

  15. European Fissure Sealant Guidelines: assessment using AGREE II.

    PubMed

    San Martin-Galindo, L; Rodríguez-Lozano, F J; Abalos-Labruzzi, C; Niederman, R

    2017-02-01

    Pit and fissure sealants are effective in reducing the incidence of occlusal caries, and multiple clinical practice guidelines (CPGs) have been developed for recommending their proper use. The usefulness of CPGs depends on their quality and on the rigour of the guideline development process. A study was made to assess the quality of current European CPGs based on the Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument, which uses 23 key items rated on a 7-point scale to assess practice guideline development and the quality of reporting. A search was conducted for fissure sealant guidelines for preventing caries in children and adults at high and low risk published in the last 10 years. Calibration was carried out before scoring to assess agreement between the appraisers using the AGREE II instrument. The searches identified 19 relevant guidelines, and following application of the inclusion/exclusion criteria, three guidelines were retained for evaluation. The proportion of observed agreement was calculated, expressed by the agreement separately for positive and negative ratings (PA = 0.89, NA = 0-91). The results of the guideline assessments revealed the highest score for the Irish guideline, a moderate score for the French guideline and the lowest score for the European guideline. Based on the AGREE II instrument, the results obtained show significant variation in the quality assessment of the three European Fissure Sealant Guidelines. Future studies should be carried out both to develop quality dental CPGs and to investigate effective ways of adopting them. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. The influence of toothbrushing and coffee staining on different composite surface coatings.

    PubMed

    Zimmerli, Brigitte; Koch, Tamara; Flury, Simon; Lussi, Adrian

    2012-04-01

    The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.

  17. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant

    PubMed Central

    Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; del Carmen Estrada-Aguilar, María; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro

    2010-01-01

    AIM: To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). METHODS: The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. RESULTS: There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 ± 14.2 d and 32.5 ± 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 ± 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 ± 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. CONCLUSION: Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas. PMID:20533600

  18. Intraoperative Intratumoral Embolization of a Complex Recurrent Hemangiopericytoma: Technical Report and Review of the Literature.

    PubMed

    Ryttlefors, Mats; Latini, Francesco; Basma, Jaafar; Krisht, Ali F

    2016-07-01

    Objective Recurrent brain tumors represent a challenge for neurosurgeons because of the extensive blood loss and the time needed for surgical resection. Only a few hemostatic agents are useful to prevent the bleeding and thus facilitate the surgical resection. Fibrin sealant can be used to achieve sealing, tissue adherence, or hemostasis when other means of hemostasis are inadequate or inappropriate. We report the feasibility and positive effects of direct intratumoral injection of fibrin sealant during resection of a recurrent hemangiopericytoma. Material and Methods The intraoperative intratumoral injection of fibrin sealant changed the tumor properties of a recurrent hemangiopericytoma of the tentorium with infra- and supratentorial extension. From a loose friable briskly bleeding tumor, this complex lesion became a nonbleeding well-demarcated soft-firm tumor that could easily be dissected off the pial surface and totally resected without extensive bleeding. Results There are several benefits of intratumoral injection of fibrin sealant in hemangiopericytomas: (1) the extensive bleeding is diminished and blood loss minimized; (2) the restriction of the surgical view by the venous oozing is diminished, making the microsurgical dissection of the tumor capsule off the pial surface easier and safer; (3) the loose consistency of the tumor becomes firmer and facilitates the manipulation of the tumor and leads to a safer resection; and (4) a shorter operating time is needed. Conclusion The use of intratumoral fibrin glue injection is a safe and useful technique that could be used for hemostasis of highly vascularized tumors to facilitate a safer resection and to reduce blood loss. Georg Thieme Verlag KG Stuttgart · New York.

  19. Treatment of gingival recession using free gingival graft with fibrin fibronectin sealing system: A novel approach

    PubMed Central

    Srinivas, B. V. V.; Rupa, N.; Halini Kumari, K. V.; Rajender, A.; Reddy, M. Narendra

    2015-01-01

    Periodontal plastic surgery is the branch of periodontology that is focused mainly on the correction or elimination of mucogingival problems associated with lack of attached gingiva, a shallow vestibule and aberrant frenum. Various mucogingival surgical procedures are used to halt the progression of the gingival recession and to correct poor esthetic appearance. Free gingival autograft is one of the most common techniques used for a gingival recession in areas of inadequate attached gingiva in the mandibular anterior region. Fibrin sealants are human plasma derivatives that mimic the final stages of blood coagulation, forming a fibrin clot. Fibrin Sealants enhances the overall outcome of surgical intervention because of their hemostatic, adhesive, and healing properties. These properties of fibrin sealants may reduce operating time, prevent complications, and enhance the overall outcome of many surgical interventions. Hence, this case report aims to investigate the clinical effectiveness of free gingival graft along with the commercially available fibrin-fibronectin sealing system (Tissucol®) in the treatment of Miller's class II gingival recession. PMID:26538956

  20. Chemically bonded phosphate ceramic sealant formulations for oil field applications

    DOEpatents

    Wagh, Arun S [Naperville, IL; Jeong, Seung-Young [Taejon, KR; McDaniel, Richard [Crest Hill, IL

    2008-10-21

    A sealant for an oil or geothermal well capable of setting within about 3 to about 6 hours at temperatures less than about 250.degree. F. for shallow wells less than about 10,000 feet and deep wells greater than about 10,000 feet having MgO present in the range of from about 9.9 to about 14.5%, KH.sub.2PO.sub.4 present in the range of from about 29.7 to about 27.2%, class C fly ash present in the range of from about 19.8 to about 36.3%, class F fly ash present in the range of from about 19.8 to about 0%, boric acid or borax present in the range of from about 0.39 to about 1.45%, and water present in the range of from about 20.3 to about 21.86% by weight of the sealant.A method of sealing wells is disclosed as are compositions for very high temperature wells is disclosed as is a composition for treating oil field wastes.

  1. Systematic review of noninvasive treatments to arrest dentin non-cavitated caries lesions

    PubMed Central

    de Assunção, Isauremi Vieira; da Costa, Giovanna de Fátima Alves; Borges, Boniek Castillo Dutra

    2014-01-01

    AIM: To systematically review the literature on the efficacy of noninvasive methods of arresting the progression of non-cavitated occlusal carious lesions in dentin. METHODS: The Medline/PubMed, LILACS, SciELO and Scopus databases were searched to identify relevant publications through to November 2013. Only clinical trials evaluating the ability of noninvasive methods to arrest the progression of occlusal non-cavitated carious lesions in dentin were included. Screening, data extraction and quality assessment were conducted independently and in duplicate. RESULTS: Of 167 citations identified, nine full text articles were screened and five were included in the analysis. All papers reported on occlusal fissure sealing using a self-curing glass ionomer (n = 1) or resin-based (n = 4) sealant. Only the use of resin-based sealant to obliterate occlusal fissures arrested the progression of non-cavitated occlusal carious lesions in dentin. CONCLUSION: Occlusal fissure sealing with a resin-based sealant may arrest the progression of non-cavitated occlusal dentinal caries. Further clinical trials with longer follow-up times should be performed to increase scientific evidence. PMID:24868513

  2. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    PubMed Central

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  3. A method to determine shear adhesive strength of fibrin sealants.

    PubMed

    Sierra, D H; Feldman, D S; Saltz, R; Huang, S

    1992-01-01

    The adhesive strength of fibrin sealants has not been rigorously evaluated to date. The adhesive strength of six different concentrations of cryoprecipitated fibrinogen as well as the commercially available fibrin tissue adhesive Tissucol was tested under controlled conditions utilizing split-thickness skin grafts as the test adherand. This test configuration permitted the modeling of bonding strength for attachment of skin grafts as well as incorporate established engineering test standards for adhesives. An increase in fibrin concentration corresponded with an increase in shear adhesive strength. No significant increases in adhesive strength were attained after 5 min of bonding for all tested concentrations, except for the commercial adhesive, which attained the adhesive strength of an equivalent concentration of cryoprecipitated adhesive after 90 min. The adhesive strength, however, was an order of magnitude less than reported values of the tensile strength of fibrin material for similar concentrations. Therefore, it is important that the surgeon use a sufficiently high fibrinogen concentration for the specific clinical indication. The method of fibrin sealant preparation and/or the compounding adjuncts appear to have an effect on the development of adhesive strength.

  4. MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S. (Inventor)

    2009-01-01

    Methods of bulk manufacturing high temperature sensor subassembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub-assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attaching wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

  5. MEMS Direct Chip Attach Packaging Methodologies and Apparatuses for Harsh Environments

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S. (Inventor)

    2005-01-01

    Methods of bulk manufacturing high temperature sensor sub-assembly packages are disclosed and claimed. Sensors are sandwiched between a top cover and a bottom cover so as to enable the peripheries of the top covers, sensors and bottom covers to be sealed and bound securely together are disclosed and claimed. Sensors are placed on the bottom covers leaving the periphery of the bottom cover exposed. Likewise, top covers are placed on the sensors leaving the periphery of the sensor exposed. Individual sensor sub- assemblies are inserted into final packaging elements which are also disclosed and claimed. Methods of directly attach- ing wires or pins to contact pads on the sensors are disclosed and claimed. Sensors, such as pressure sensors and accelerometers, and headers made out of silicon carbide and aluminum nitride are disclosed and claimed. Reference cavities are formed in some embodiments disclosed and claimed herein where top covers are not employed.

  6. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2014-07-01

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  7. High-energy metal air batteries

    DOEpatents

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2013-07-09

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  8. A case series of anophthalmic socket cysts excised utilising fibrin sealant.

    PubMed

    Wong, Yun; Clarke, Lucy; Lau, Gordon

    2017-10-23

    Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.

  9. Lamination cooling system formation method

    DOEpatents

    Rippel, Wally E [Altadena, CA; Kobayashi, Daryl M [Monrovia, CA

    2012-06-19

    An electric motor, transformer or inductor having a cooling system. A stack of laminations have apertures at least partially coincident with apertures of adjacent laminations. The apertures define straight or angled cooling-fluid passageways through the lamination stack. Gaps between the adjacent laminations are sealed by injecting a heat-cured sealant into the passageways, expelling excess sealant, and heat-curing the lamination stack. Manifold members adjoin opposite ends of the lamination stack, and each is configured with one or more cavities to act as a manifold to adjacent passageway ends. Complex manifold arrangements can create bidirectional flow in a variety of patterns.

  10. Lamination cooling system formation method

    DOEpatents

    Rippel, Wally E [Altadena, CA; Kobayashi, Daryl M [Monrovia, CA

    2009-05-12

    An electric motor, transformer or inductor having a cooling system. A stack of laminations have apertures at least partially coincident with apertures of adjacent laminations. The apertures define straight or angled cooling-fluid passageways through the lamination stack. Gaps between the adjacent laminations are sealed by injecting a heat-cured sealant into the passageways, expelling excess sealant, and heat-curing the lamination stack. Manifold members adjoin opposite ends of the lamination stack, and each is configured with one or more cavities to act as a manifold to adjacent passageway ends. Complex manifold arrangements can create bidirectional flow in a variety of patterns.

  11. MEMS Reliability Assurance Guidelines for Space Applications

    NASA Technical Reports Server (NTRS)

    Stark, Brian (Editor)

    1999-01-01

    This guide is a reference for understanding the various aspects of microelectromechanical systems, or MEMS, with an emphasis on device reliability. Material properties, failure mechanisms, processing techniques, device structures, and packaging techniques common to MEMS are addressed in detail. Design and qualification methodologies provide the reader with the means to develop suitable qualification plans for the insertion of MEMS into the space environment.

  12. Rationale for patient package inserts.

    PubMed

    Morris, L A

    1978-02-01

    The need for patient package inserts (PPIs) is discussed in terms of the "consumers' right-to-know" and "patient health education" themes, as well as the premise that verbal means of communication are often inadequate. Some of the reasons for the frequent failure of verbal messages are reviewed by detailing the five stages through which any communication must be processed in order to be effective. Verbal information may be inadequate because: (1) patients are not exposed to necessary material, (2) they may not pay attention to the information, (3) they may not understand it, (4) the information may not be accepted as valid, and (5) patients may not remember the material. Written communication which must be processed through the same five stages also may be frequently inadequate. Therefore, PPIs must be viewed as reinforcing and augmenting verbal consultation, and both written and verbal forms are necessary. Consumer surveys and demonstration projects have shown that written communications are a desired and effective means for conveying additional prescription drug information to patients. The wide implementation of PPIs is apt to cause many problems for the pharmacists; however, it may also serve as a means to enhance the pharmacist's clinical role.

  13. Graphical content of medicinal package inserts: an exploratory study to evaluate potential legibility issues.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2016-06-01

    The graphical content of the Medicines Package Inserts (MPIs), such as illustrations and typographic features should be legible and appropriate, as required by international pharmaceutical regulations. To study: (1) the frequency and type of MPIs' key graphic elements, (2) their compliance with regulations and (3) how educated people understand them. Descriptive study: characterisation of the graphical content of 651 MPIs. Usability study: illustrations and tables (purposively selected) were evaluated with questionnaires in three groups of humanities undergraduates (illustrations only, illustrations plus text and text only). Descriptive study: illustrations and tables were respectively identified in 6.3% and 11.8% of the MPIs. The illustrations were mainly related to how to take/use the medicine. Non-recommended graphical representations were found (e.g. italic or underline). Usability test: legibility issues were identified, especially for the group of isolated illustrations. The scarce use of illustrations and tables possibly affected the legibility of the MPIs. Compulsory legibility tests are needed to guarantee the MPIs' proper use, thus contributing to a safe use of medicines. Overall, this study highlighted the need to carefully revise/assess the MPIs' design and probably increase health information experts' awareness on this issue. © 2015 Health Libraries Group.

  14. Economic Evaluation of a School-based Combined Program with a Targeted Pit and Fissure Sealant and Fluoride Mouth Rinse in Japan.

    PubMed

    Sakuma, Shihoko; Yoshihara, Akihiro; Miyazaki, Hideo; Kobayashi, Seigo

    2010-01-01

    In Niigata prefecture, Japan, a system has been developed based on a school-based fluoride mouth rinse program as follows; students with caries susceptible teeth are screened in a school dental examination, and encouraged to receive sealant placement in local dental clinics. However, the cost-effectiveness of sealant application in the public health has been questioned. The aim of this study was to estimate of the cost-effectiveness and cost-benefit ratio for a school-based combined program with fluoride mouth rinse and targeted fissure sealant in children residing in non-fluoridated areas in Japan. The analysis was based on comparing an intervention group with two cohorts in the 8-year-old (n=66) and 11-year-old (n=58) participating in the combined program for four and seven years, respectively, with a control group of the same grades (n=43 and n=54 respectively). The study measured mean differences in number of decayed and filled teeth (DFT) between the study groups and a combined program cost per child during study periods. The cost-effectiveness ratio was expressed as an individual annual program cost per DFT averted. In the cost-benefit ratio the mean difference in treatment cost between groups (program benefit) was compared to program cost. The mean reduced DFT differences between groups were 1.44 in 8-year-old and 3.17 in 11-year-old children. The cost-effectiveness ratio was ¥ 493 in the 8-year-old and ¥ 202 in the 11-year-old, respectively. The cost-benefit ratio was 1.84 in 8-year-old children and 2.42 in 11-year-old. This combined program indicated acceptable cost-effectiveness and cost -benefit ratio.

  15. Thermal stress analysis of a planar SOFC stack

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Kuang; Chen, Tsung-Ting; Chyou, Yau-Pin; Chiang, Lieh-Kwang

    The aim of this study is, by using finite element analysis (FEA), to characterize the thermal stress distribution in a planar solid oxide fuel cell (SOFC) stack during various stages. The temperature profiles generated by an integrated thermo-electrochemical model were applied to calculate the thermal stress distributions in a multiple-cell SOFC stack by using a three-dimensional (3D) FEA model. The constructed 3D FEA model consists of the complete components used in a practical SOFC stack, including positive electrode-electrolyte-negative electrode (PEN) assembly, interconnect, nickel mesh, and gas-tight glass-ceramic seals. Incorporation of the glass-ceramic sealant, which was never considered in previous studies, into the 3D FEA model would produce more realistic results in thermal stress analysis and enhance the reliability of predicting potential failure locations in an SOFC stack. The effects of stack support condition, viscous behavior of the glass-ceramic sealant, temperature gradient, and thermal expansion mismatch between components were characterized. Modeling results indicated that a change in the support condition at the bottom frame of the SOFC stack would not cause significant changes in thermal stress distribution. Thermal stress distribution did not differ significantly in each unit cell of the multiple-cell stack due to a comparable in-plane temperature profile. By considering the viscous characteristics of the glass-ceramic sealant at temperatures above the glass-transition temperature, relaxation of thermal stresses in the PEN was predicted. The thermal expansion behavior of the metallic interconnect/frame had a greater influence on the thermal stress distribution in the PEN than did that of the glass-ceramic sealant due to the domination of interconnect/frame in the volume of a planar SOFC assembly.

  16. Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks.

    PubMed

    Park, Bernard J; Snider, John M; Bates, Nathan R; Cassivi, Stephen D; Jett, G Kimble; Sonett, Joshua R; Toloza, Eric M

    2016-12-12

    A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. In a multicenter prospective single-arm trial, 112 patients with a median age of 69 years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1 month after surgery for procedure-related and device-related complications and presence of air leak. Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2 days (range 1 - 46 days), and median length of hospitalization was 3 days (range 1 - 20 days). This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. ClinicalTrials.gov: NCT01867658 . Registered 3 May 2013.

  17. A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial.

    PubMed

    Glickman, Marc; Gheissari, Ali; Money, Samuel; Martin, John; Ballard, Jeffrey L

    2002-03-01

    An experimental polymeric sealant (CoSeal [Cohesion Technologies, Palo Alto, Calif]) provides equivalent anastomotic sealing to Gelfoam (Upjohn, Kalamazoo, Mich)/thrombin during surgical placement of prosthetic vascular grafts. Randomized controlled trial. Nine university-affiliated medical centers. One hundred forty-eight patients scheduled for implantation of polytetrafluoroethylene grafts, mainly for infrainguinal revascularization procedures or the creation of dialysis access shunts, who were treated randomly with either an experimental intervention (n = 74) or control (n = 74). Following polytetrafluoroethylene graft placement, anastomotic suture hole bleeding was treated intraoperatively in all control subjects with Gelfoam/thrombin. Subjects in the experimental group had the polymeric sealant applied directly to the suture lines without concomitant manual compression. Primary treatment success was defined as the proportion of subjects in each group that achieved complete anastomotic sealing within 10 minutes. The proportion of subjects that achieved immediate sealing and the time required to fully inhibit suture hole bleeding also were compared between treatment groups. Overall 10-minute sealing success was equivalent (86% vs 80%; P =.29) between experimental and control subjects, respectively. However, subjects treated with CoSeal achieved immediate anastomotic sealing at more than twice the rate of subjects treated with Gelfoam/thrombin (47% vs 20%; P<.001). Consequently, the median time needed to inhibit bleeding in control subjects was more than 10 times longer than for experimental subjects (16.5 seconds vs 189.0 seconds; P =.01). Strikingly similar findings for all comparisons were observed separately for subgroups of subjects having infrainguinal bypass grafting and for those undergoing placement of dialysis access shunts. The experimental sealant offers equivalent anastomotic sealing performance compared with Gelfoam/thrombin, but it provides this desired effect in a significantly more rapid time frame.

  18. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  19. Intradiscal injection of fibrin sealant for the treatment of symptomatic lumbar internal disc disruption: results of a prospective multicenter pilot study with 24-month follow-up.

    PubMed

    Yin, Way; Pauza, Kevin; Olan, Wayne J; Doerzbacher, Jeff F; Thorne, Kevin J

    2014-01-01

    Assess the safety and efficacy of intradiscal fibrin sealant in adults with chronic discogenic low back pain. Prospective, nonrandomized Food and Drug Administration approved pilot study. Three centers in the United States. Fifteen adults with chronic, single, or contiguous two-level lumbar discogenic pain confirmed through meticulous provocation discography. Volume- and pressure-controlled intradiscal delivery of BIOSTAT BIOLOGX(®) Fibrin Sealant with the Biostat(®) Delivery Device into symptomatic lumbar disc(s). Assessments were performed at baseline, 72 hours, and 1, 4, 13, 26, 52, and 104 weeks following intervention. Potential adverse events were evaluated with serial assessment of neurological status, radiographic, and magnetic resonance imaging (MRI). Efficacy measures included serial assessments of low back pain visual analog scale (VAS) measurements and the Roland-Morris Disability Questionnaire (RMDQ). Safety neurological assessments, X-ray, and MRI showed no significant changes. Adverse events were reported in nine subjects. Two instances of low back muscle spasm and one case of discitis were the only events considered related to the procedure or product. Mean low back pain VAS scores (mm) decreased from 72.4 (95% confidence interval 64.6-80.3) at baseline to 31.7 (17.4-46.1), 35.4 (17.7-53.1), and 33.0 (16.3-49.6); mean RMDQ score improved from 15.2 (12.7-17.7) at baseline to 8.9 (5.3-12.5), 6.2 (3.4-9.1), and 5.6 (2.9-8.4) at 26, 52, and 104 weeks, respectively. Intradiscal injection of BIOSTAT BIOLOGX Fibrin Sealant with the Biostat Delivery Device appears safe and may improve pain and function in selected patients with discogenic pain. Wiley Periodicals, Inc.

  20. Fibrin Tissue Sealant as an Adjunct to Cleft Palate Repair.

    PubMed

    Wu, Robin; Wilson, Alexander; Travieso, Roberto; Steinbacher, Derek M

    2017-07-01

    Fibrin glue is a common tissue sealant used to promote hemostasis, adhere tissues, and accelerate healing. Cleft palate repair can be technically challenging, creating dead space between tissue planes, and can be prone to complications such as would dehiscence or bleeding. The purpose of this study is to assess the role of fibrin glue as an adjunct to cleft palate repair. The authors hypothesize a beneficial impact on complication rates, including bleeding, dehiscence, and fistula formation, among others. Primary cleft palate repairs using fibrin glue were retrospectively analyzed. Demographic, intraoperative, perioperative, and postoperative data were combed for outcome variables. Complication rates were calculated in percentages and the results were compared to the published literature. Z-test statistics were performed for comparison. A total of 45 patients, 21 females and 24 males, who underwent primary cleft palate repair with fibrin glue between 2011 and 2014, had sufficient data to be reviewed. There were no instances of bleeding, dehiscence, airway obstruction, infection, oronasal fistula, or return to the operating room in any patients. One patient exhibited mild postoperative coughing and secretions that resolved with conservative measures. Another patient displayed postoperative seizure activity due to a pre-existing condition. All complication rates in our fibrin glue series were lower than those reported without the use of fibrin glue. Overall complication rates with fibrin sealant are significantly lower than overall complication rates without. Our data suggest that fibrin sealant is a beneficial adjunct to cleft palate repair. Its application is well-tolerated and the complication profile in our cohort was much less than the reported rates. The results of this preliminary study should be vetted with a prospective analysis involving a control group.

  1. Comparison between different interdental stripping methods and evaluation of abrasive strips: SEM analysis.

    PubMed

    Grippaudo, Cristina; Cancellieri, Daniela; Grecolini, Maria E; Deli, Roberto

    2010-01-01

    The aim of this study was to evaluate the morphological effects and the surface irregularities produced by different methods of mechanical stripping (abrasive strips and burs) and chemical stripping (37% orthophosphoric acid) and the surface changes following the finishing procedures (polishing strips) or the subsequent application of sealants, in order to establish the right stripping method that can guarantee the smoothest surface. We have also analysed the level of wear on the different abrasive strips employed, according to their structure. 160 proximal surfaces of 80 sound molar teeth extracted for orthodontic and periodontal reasons, were divided into: 1 control group with non-treated enamel proximal surfaces and 5 different groups according to the stripping method used, were observed with scanning electron microscopy (SEM). Each one of the 5 treated groups was also divided into 3 different subgroups according to the finishing procedures or the subsequent application of sealants. The finishing stage following the manual reduction proves to be fundamental in reducing the number and depth of grooves created by the stripping. After the air rotor stripping method, the use of sealants is advised in order to obtain a smoother surface. The analysis of the combinations of mechanical and chemical stripping showed unsatisfactory results. Concerning the wear of the strips, we have highlighted a different abrasion degree for the different types of strips analysed with SEM. The enamel damages are limited only if the finishing procedure is applied, independently of the type of abrasive strip employed. It would be advisable, though clinically seldom possible, the use of sealants after the air rotor stripping technique. Copyright © 2010 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

  2. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendelsohn, M A; Luck, R M; Yeoman, F A

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance ofmore » these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.« less

  3. A small and efficient dimerization/packaging signal of rat VL30 RNA and its use in murine leukemia virus-VL30-derived vectors for gene transfer.

    PubMed

    Torrent, C; Gabus, C; Darlix, J L

    1994-02-01

    Retroviral genomes consist of two identical RNA molecules associated at their 5' ends by the dimer linkage structure located in the packaging element (Psi or E) necessary for RNA dimerization in vitro and packaging in vivo. In murine leukemia virus (MLV)-derived vectors designed for gene transfer, the Psi + sequence of 600 nucleotides directs the packaging of recombinant RNAs into MLV virions produced by helper cells. By using in vitro RNA dimerization as a screening system, a sequence of rat VL30 RNA located next to the 5' end of the Harvey mouse sarcoma virus genome and as small as 67 nucleotides was found to form stable dimeric RNA. In addition, a purine-rich sequence located at the 5' end of this VL30 RNA seems to be critical for RNA dimerization. When this VL30 element was extended by 107 nucleotides at its 3' end and inserted into an MLV-derived vector lacking MLV Psi +, it directed the efficient encapsidation of recombinant RNAs into MLV virions. Because this VL30 packaging signal is smaller and more efficient in packaging recombinant RNAs than the MLV Psi + and does not contain gag or glyco-gag coding sequences, its use in MLV-derived vectors should render even more unlikely recombinations which could generate replication-competent viruses. Therefore, utilization of the rat VL30 packaging sequence should improve the biological safety of MLV vectors for human gene transfer.

  4. A fully wafer-level packaged RF MEMS switch with low actuation voltage using a piezoelectric actuator

    NASA Astrophysics Data System (ADS)

    Park, Jae-Hyoung; Lee, Hee-Chul; Park, Yong-Hee; Kim, Yong-Dae; Ji, Chang-Hyeon; Bu, Jonguk; Nam, Hyo-Jin

    2006-11-01

    In this paper, a fully wafer-level packaged RF MEMS switch has been demonstrated, which has low operation voltage, using a piezoelectric actuator. The piezoelectric actuator was designed to operate at low actuation voltage for application to advanced mobile handsets. The dc contact type RF switch was packaged using the wafer-level bonding process. The CPW transmission lines and piezoelectric actuators have been fabricated on separate wafers and assembled together by the wafer-level eutectic bonding process. A gold and tin composite was used for eutectic bonding at a low temperature of 300 °C. Via holes interconnecting the electrical contact pads through the wafer were filled completely with electroplated copper. The fully wafer-level packaged RF MEMS switch showed an insertion loss of 0.63 dB and an isolation of 26.4 dB at 5 GHz. The actuation voltage of the switch was 5 V. The resonant frequency of the piezoelectric actuator was 38.4 kHz and the spring constant of the actuator was calculated to be 9.6 N m-1. The size of the packaged SPST (single-pole single-through) switch was 1.2 mm × 1.2 mm including the packaging sealing rim. The effect of the proposed package structure on the RF performance was characterized with a device having CPW through lines and vertical feed lines excluding the RF switches. The measured packaging loss was 0.2 dB and the return loss was 33.6 dB at 5 GHz.

  5. Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model

    PubMed Central

    Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Background and Objectives: Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. Methods: Anesthetized 20-kg to 25-kg female Yorkshire pigs underwent laparoscopy performed using a 3-trocar technique. Peritoneal incisions were made and pockets created in the preperitoneal space for mesh placement. Parietex TEC mesh segments embedded in 60% collagen-solder were soldered to the muscle surface by using a prototype laser (1.45µ, 4.5W CW, 5mm spot, and 55°C set temperature) and custom laparoscopic handpiece. Parietex TEC mesh segments (Control) were affixed to the muscle with fibrin sealant (Tisseel). Peritoneal closure was with staples (Control) or by soldering collagen embedded Vicryl mesh segments over the peritoneal incision (Mesh/TAPP). Segments were inserted using a specially designed introducer. Animals were recovered and underwent second-look laparoscopy at 6 weeks postimplantation. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in the TAPP approach. Tisseel tended to drip during application, particularly in vertical and ventral locations. Postoperative healing was similar to Control segments in all cases. Mesh/TAPP closures healed without scarring or adhesion formation. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce use of staples for laparoscopic mesh fixation and peritoneal closure. Laser-assisted mesh fixation and peritoneal closure is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19660214

  6. Differences in the Language and Design of Four PPIs for Valium. Technical Assistance Report No. 1.

    ERIC Educational Resources Information Center

    Redish, Janice C.

    As part of the evaluation of four different versions of a patient package insert (PPI) for diazepam (Valium) created by the Food and Drug Administration (FDA), the content, organization, language, and design of the PPIs were compared. One PPI was a short prose piece with clear organization that did not particularly highlight warnings or, indeed,…

  7. Splenic injury during percutaneous nephrolithotomy.

    PubMed

    Thomas, Anil A; Pierce, Gregory; Walsh, R Matthew; Sands, Mark; Noble, Mark

    2009-01-01

    Injury to the spleen is a recognized complication during percutaneous renal access due to the close anatomical relationship of the spleen and the left kidney. However, transsplenic renal access is a rare complication of percutaneous nephrolithotomy and can also result in considerable morbidity, often requiring emergent splenectomy. We present our experience with splenic injury during percutaneous nephrolithotomy managed conservatively with the use of a collagen-thrombin hemostatic sealant (D-Stat; Vascular Solutions, Inc., Minneapolis, MN) after delayed removal of the nephrostomy tubes. The patient had an uneventful recovery and was discharged home on postoperative day 6. In select hemodynamically stable patients, nonoperative management with the adjunctive use of hemostatic sealants may be considered.

  8. Hypersensitivity to sub-Tenon's topotecan in fibrin adhesive in patients with retinoblastoma.

    PubMed

    Astudillo, Paulita Pamela P; Durairaj, Priya; Chan, Helen S L; Héon, Elise; Gallie, Brenda L

    2015-02-01

    Sub-Tenon's space delivery of topotecan in a fibrin sealant was used as an adjunct to laser therapy for small retinoblastoma tumors in 25 children (77 injections). We report serious hypersensitivity reactions in 2 children on their third sub-Tenon's injection of topotecan in fibrin sealant. One child subsequently had topotecan in an autologous blood clot with no allergic reaction. Although allergic reaction to topotecan has been reported in the literature, fibrin glue reactions are more common and are likely due to aprotinin hypersensitivity. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  9. Dystrophic heart failure blocked by membrane sealant poloxamer

    NASA Astrophysics Data System (ADS)

    Yasuda, Soichiro; Townsend, Dewayne; Michele, Daniel E.; Favre, Elizabeth G.; Day, Sharlene M.; Metzger, Joseph M.

    2005-08-01

    Dystrophin deficiency causes Duchenne muscular dystrophy (DMD) in humans, an inherited and progressive disease of striated muscle deterioration that frequently involves pronounced cardiomyopathy. Heart failure is the second leading cause of fatalities in DMD. Progress towards defining the molecular basis of disease in DMD has mostly come from studies on skeletal muscle, with comparatively little attention directed to cardiac muscle. The pathophysiological mechanisms involved in cardiac myocytes may differ significantly from skeletal myofibres; this is underscored by the presence of significant cardiac disease in patients with truncated or reduced levels of dystrophin but without skeletal muscle disease. Here we show that intact, isolated dystrophin-deficient cardiac myocytes have reduced compliance and increased susceptibility to stretch-mediated calcium overload, leading to cell contracture and death, and that application of the membrane sealant poloxamer 188 corrects these defects in vitro. In vivo administration of poloxamer 188 to dystrophic mice instantly improved ventricular geometry and blocked the development of acute cardiac failure during a dobutamine-mediated stress protocol. Once issues relating to optimal dosing and long-term effects of poloxamer 188 in humans have been resolved, chemical-based membrane sealants could represent a new therapeutic approach for preventing or reversing the progression of cardiomyopathy and heart failure in muscular dystrophy.

  10. Electrical behavior of aluminosilicate glass-ceramic sealants and their interaction with metallic solid oxide fuel cell interconnects

    NASA Astrophysics Data System (ADS)

    Goel, Ashutosh; Tulyaganov, Dilshat U.; Kharton, Vladislav V.; Yaremchenko, Aleksey A.; Ferreira, José M. F.

    A series of alkaline-earth aluminosilicate glass-ceramics (GCs) were appraised with respect to their suitability as sealants for solid oxide fuel cells (SOFCs). The parent composition with general formula Ca 0.9MgAl 0.1La 0.1Si 1.9O 6 was modified with Cr 2O 3 and BaO. The addition of BaO led to a substantial decrease in the total electrical conductivity of the GCs, thus improving their insulating properties. BaO-containing GCs exhibited higher coefficient of thermal expansion (CTE) in comparison to BaO-free GCs. An extensive segregation of oxides of Ti and Mn, components of the Crofer22 APU interconnect alloy, along with negligible formation of BaCrO 4 was observed at the interface between GC/interconnects diffusion couples. Thermal shock resistance and gas-tightness of GC sealants in contact with yttria-stabilized zirconia electrolyte (8YSZ) was evaluated in air and water. Good matching of CTE and strong, but not reactive, adhesion to the solid electrolyte and interconnect, in conjunction with a high level of electrical resistivity, are all advantageous for potential SOFC applications.

  11. [Bond strengths of absorbable polylactic acid root canal post with three different adhesives].

    PubMed

    Pan, Hui; Cheng, Can; Hu, Jia; Liu, He; Sun, Zhi-hui

    2015-12-18

    To find absorbable adhesives with suitable bonding properties for the absorbable polylactic acid root canal post. To test and compare the bond strengths of absorbable polylactic acid root canal post with three different adhesives. The absorbable polylactic acid root canal posts were used to restore the extracted teeth, using 3 different adhesives: cyanoacrylates, fibrin sealant and glass ionomer cement. The teeth were prepared into slices for micro-push-out test. The bond strength was statistically analyzed using ANOVA. The specimens were examined using microscope and the failure mode was divided into four categories: cohesive failure between absorbable polylactic acid root canal posts and adhesives, cohesive failure between dentin and adhesives, failure within the adhesives and failure within the absorbable polylactic acid root canal posts. The bond strength of cyanoacrylates [(16.83 ± 6.97) MPa] and glass ionomer cement [(12.10 ± 5.09) MPa] were significantly higher than fibrin sealant [(1.17 ± 0.50) MPa], P<0.001. There was no significant difference between cyanoacrylates and glass ionomer cement (P=0.156). In the group of cyanoacrylates, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 25.0%, the cohesive failure between the dentin and the adhesives was 16.7%, the failure within the adhesives was 33.3%, and the failure within the absorbable polylactic acid root canal posts was 25.0%. In the group of fibrin sealant, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 66.7%, the cohesive failure between the dentin and the adhesives was 22.2%, the failure within the adhesives was 11.1%. In the group of glass ionomer cement, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 87.5%, the failure within the adhesives was 12.5%. The major failure mode in fibrin sealant and glass ionomer cement was the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives. No major failure modes were found in the group of cyanoacrylates. The bond strength of fibrin sealant is low, which cannot meet the requirement of clinical use. The bond strengths of cyanoacrylates and glass ionomer cement are suitable for clinical use. The cyanoacrylates are a kind of absorbable adhesive which has suitable bonding properties for the absorbable polylactic acid root canal post.

  12. Twenty-five-year atraumatic restorative treatment (ART) approach: a comprehensive overview.

    PubMed

    Frencken, Jo E; Leal, Soraya Coelho; Navarro, Maria Fidela

    2012-10-01

    The atraumatic restorative treatment (ART) approach was born 25 years ago in Tanzania. It has evolved into an essential caries management concept for improving quality and access to oral care globally. Meta-analyses and systematic reviews have indicated that the high effectiveness of ART sealants using high-viscosity glass ionomers in carious lesion development prevention is not different from that of resin fissure sealants. ART using high-viscosity glass ionomer can safely be used to restore single-surface cavities both in primary and in permanent posterior teeth, but its quality in restoring multiple surfaces in primary posterior teeth cavities needs to be improved. Insufficient information is available regarding the quality of ART restorations in multiple surfaces in permanent anterior and posterior teeth. There appears to be no difference in the survival of single-surface high-viscosity glass-ionomer ART restorations and amalgam restorations. The use of ART results in smaller cavities and in high acceptance of preventive and restorative care by children. Because local anaesthesia is seldom needed and only hand instruments are used, ART is considered to be a promising approach for treating children suffering from early childhood caries. ART has been implemented in the public oral health services of a number of countries, and clearly, proper implementation requires the availability of sufficient stocks of good high-viscosity glass ionomers and sets of ART instruments right from the start. Textbooks including chapters on ART are available, and the concept is being included in graduate courses at dental schools in a number of countries. Recent development and testing of e-learning modules for distance learning has increasingly facilitated the distribution of ART information amongst professionals, thus enabling more people to benefit from ART. However, this development and further research require adequate funding, which is not always easily obtainable. The next major challenge is the continuation of care to the frail elderly, in which ART may play a part. ART, as part of the Basic Package of Oral Care, is an important cornerstone for the development of global oral health and alleviating inequality in oral care.

  13. Influence of the Thermal Conductivity of Thermally Conductive Plastics on the Thermal Distribution of an Light-Emitting Diode Headlight for Vehicles.

    PubMed

    Lee, Dong Kyu; Lee, Jae Min; Cho, Moon Uk; Park, Hyun Jung; Cha, Yu-Jung; Kim, Hyeong Jin; Kwak, Joon Seop

    2018-09-01

    This paper investigates the thermal distribution of an LED headlight for vehicles based on the thermal conductivity of thermally conductive plastics (TCP). In general, heat dissipation structures used for LED headlights are made from metallic materials. However, headlight structures made from TCP have not been investigated. The headlights made from TCP having a various thermal conductivity were fabricated by injection molding with and without a metal plate insert. The temperature characteristics were compared and analyzed using thermal simulations and measurement. The inserted metal in TCP greatly reduced the temperature at solder point, indicating that the fast heat dissipation from the high power LED package to TCP though the inserted metal is essential. The measured temperature at solder points decreased as the thermal conductivity of TCP increased, which is well matched to the simulation results. The measured temperature at the solder point was lower than 150 °C when the thermal conductivity of the TCP was 10 W/mK.

  14. An alphavirus temperature-sensitive capsid mutant reveals stages of nucleocapsid assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Yan, E-mail: yzheng15@students.kgi.edu; Kielian, Margaret, E-mail: margaret.kielian@einstein.yu.edu

    2015-10-15

    Alphaviruses have a nucleocapsid core composed of the RNA genome surrounded by an icosahedral lattice of capsid protein. An insertion after position 186 in the capsid protein produced a strongly temperature-sensitive growth phenotype. Even when the structural proteins were synthesized at the permissive temperature (28 °C), subsequent incubation of the cells at the non-permissive temperature (37 °C) dramatically decreased mutant capsid protein stability and particle assembly. Electron microscopy confirmed the presence of cytoplasmic nucleocapsids in mutant-infected cells cultured at the permissive temperature, but these nucleocapsids were not stable to sucrose gradient separation. In contrast, nucleocapsids isolated from mutant virus particlesmore » had similar stability to that of wildtype virus. Our data support a model in which cytoplasmic nucleocapsids go through a maturation step during packaging into virus particles. The insertion site lies in the interface between capsid proteins in the assembled nucleocapsid, suggesting the region where such a stabilizing transition occurs. - Highlights: • We characterize an alphavirus capsid insertion mutation. • These capsid mutants are highly temperature sensitive for growth. • The insertion affects nucleocapsid stability. • Results suggest that the nucleocapsid is stabilized during virus budding.« less

  15. Influence of irradiation by a novel CO2 9.3-μm short-pulsed laser on sealant bond strength.

    PubMed

    Rechmann, P; Sherathiya, K; Kinsel, R; Vaderhobli, R; Rechmann, B M T

    2017-04-01

    The objective of this in vitro study was to evaluate whether irradiation of enamel with a novel CO 2 9.3-μm short-pulsed laser using energies that enhance caries resistance influences the shear bond strength of composite resin sealants to the irradiated enamel. Seventy bovine and 240 human enamel samples were irradiated with a 9.3-μm carbon dioxide laser (Solea, Convergent Dental, Inc., Natick, MA) with four different laser energies known to enhance caries resistance or ablate enamel (pulse duration from 3 μs at 1.6 mJ/pulse to 43 μs at 14.9 mJ/pulse with fluences between 3.3 and 30.4 J/cm 2 , pulse repetition rate between 4.1 and 41.3 Hz, beam diameter of 0.25 mm and 1-mm spiral pattern, and focus distance of 4-15 mm). Irradiation was performed "freehand" or using a computerized, motor-driven stage. Enamel etching was achieved with 37% phosphoric acid (Scotchbond Universal etchant, 3M ESPE, St. Paul, MN). As bonding agent, Adper Single Bond Plus was used followed by placing Z250 Filtek Supreme flowable composite resin (both 3M ESPE). After 24 h water storage, a single-plane shear bond test was performed (UltraTester, Ultradent Products, Inc., South Jordan, UT). All laser-irradiated samples showed equal or higher bond strength than non-laser-treated controls. The highest shear bond strength values were observed with the 3-μs pulse duration/0.25-mm laser pattern (mean ± SD = 31.90 ± 2.50 MPa), representing a significant 27.4% bond strength increase over the controls (25.04 ± 2.80 MPa, P ≤ 0.0001). Two other caries-preventive irradiation (3 μs/1 mm and 7 μs/0.25 mm) and one ablative pattern (23 μs/0.25 mm) achieved significantly increased bond strength compared to the controls. Bovine enamel also showed in all test groups increased shear bond strength over the controls. Computerized motor-driven stage irradiation did not show superior bond strength values over the clinically more relevant freehand irradiation. Enamel that is made caries-resistant with CO 2 9.3-μm short-pulsed laser irradiation showed at least equal or significantly higher shear bond strength to pit and fissure sealants than non-laser-irradiated enamel. The risk of a sealant failure due to CO 2 9.3-μm short-pulsed laser irradiation appears reduced. If additional laser ablation is required before placing a sealant, the CO 2 9.3-μm enamel laser-cut showed equivalent or superior bond strength to a flowable sealant.

  16. A powerful enhancement to the DMAP alter capability

    NASA Technical Reports Server (NTRS)

    Pamidi, P. R.

    1989-01-01

    A powerful enhancement to the DMAP alter capability was developed and is available on all RPK-supported versions of COSMIC/NASTRAN. This enhancement involves the addition of two alter control cards, called INSERT and DELETE, to the Executive Control Deck. These cards allow for DMAP alters to be made by referencing DMAP statements by their module names rather than by their statement numbers in the rigid format DMAP sequence. This allows for increased user convenience and flexibility and makes alters more meaningful to the user. In addition, DMAP alter packages employing the alter control cards will be much less susceptible to future changes in rigid format DMAPs than alter packages employing the standard ALTER control cards. The usage of the cards is illustrated by examples.

  17. Unlocking Short Read Sequencing for Metagenomics

    DOE PAGES

    Rodrigue, Sébastien; Materna, Arne C.; Timberlake, Sonia C.; ...

    2010-07-28

    We describe an experimental and computational pipeline yielding millions of reads that can exceed 200 bp with quality scores approaching that of traditional Sanger sequencing. The method combines an automatable gel-less library construction step with paired-end sequencing on a short-read instrument. With appropriately sized library inserts, mate-pair sequences can overlap, and we describe the SHERA software package that joins them to form a longer composite read.

  18. Consumer and health literacy: The need to better design tobacco-cessation product packaging, labels, and inserts.

    PubMed

    Weiss, Stephanie M; Smith-Simone, Stephanie Y

    2010-03-01

    Tobacco-cessation product packaging and instruction materials may not be appropriate for some smokers and may contribute to the underuse and misuse of evidence-based treatments. The dual goals of this project are to analyze literacy levels of Food and Drug Administration (FDA)-approved and non-approved tobacco-cessation product packaging, directions, and claims, and to identify and categorize claims found on product packaging. The Campaign for Tobacco Free Kids (CTFK) maintains the Quitting and Reducing Tobacco Use Inventory of Products (QuiTIP) database, which catalogs products marketed and sold to consumers to reduce or quit use of tobacco products. It also includes all medications approved by the FDA for tobacco cessation as well as a sample of non-approved products such as homeopathic, herbal, nutritional, or dietary supplements commonly marketed as either cessation aids or alternative tobacco/nicotine products. This paper assesses the reading levels required to understand product packaging, labeling, and instructions using the Simple Measure of Gobbledygook (SMOG) and identifies claims on the product package labels using standard qualitative methods. Key findings show that the average reading levels needed to understand instructions for both FDA-approved and non-approved cessation products are above the reading levels recommended to ensure maximum comprehension. Improving the packaging and directions of evidence-based tobacco-cessation products so that they are preferably at or below a fifth-grade reading level, along with using consumer-based design principles to develop packaging, may help smokers take advantage of and correctly use products that will greatly increase their chances of successful quitting. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    NASA Technical Reports Server (NTRS)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  20. Variation in Prescribing Patterns and Therapeutic Drug Monitoring of Intravenous Busulfan in Pediatric Hematopoietic Cell Transplant Recipients

    PubMed Central

    McCune, Jeannine S.; Baker, K. Scott; Blough, David K.; Gamis, Alan; Bemer, Meagan J.; Kelton-Rehkopf, Megan C.; Winter, Laura; Barrett, Jeffrey S.

    2016-01-01

    Personalizing intravenous (IV) busulfan doses in children using therapeutic drug monitoring (TDM) is an integral component of hematopoietic cell transplant. The authors sought to characterize initial dosing and TDM of IV busulfan, along with factors associated with busulfan clearance, in 729 children who underwent busulfan TDM from December 2005 to December 2008. The initial IV busulfan dose in children weighing ≤12 kg ranged 4.8-fold, with only 19% prescribed the package insert dose of 1.1 mg/kg. In those children weighing >12 kg, the initial dose ranged 5.4-fold, and 79% were prescribed the package insert dose. The initial busulfan dose achieved the target exposure in only 24.3% of children. A wide range of busulfan exposures were targeted for children with the same disease (eg, 39 target busulfan exposures for the 264 children diagnosed with acute myeloid leukemia). Considerable heterogeneity exists regarding when TDM is conducted and the number of pharmacokinetic samples obtained. Busulfan clearance varied by age and dosing frequency but not by underlying disease. The authors’ group is currently evaluating how using population pharmacokinetics to optimize initial busulfan dose and TDM (eg, limited sampling schedule in conjunction with maximum a posteriori Bayesian estimation) may affect clinical outcomes in children. PMID:23444282

Top