Design and Optimization of the SPOT Primary Mirror Segment
NASA Technical Reports Server (NTRS)
Budinoff, Jason G.; Michaels, Gregory J.
2005-01-01
The 3m Spherical Primary Optical Telescope (SPOT) will utilize a single ring of 0.86111 point-to-point hexagonal mirror segments. The f2.85 spherical mirror blanks will be fabricated by the same replication process used for mass-produced commercial telescope mirrors. Diffraction-limited phasing will require segment-to-segment radius of curvature (ROC) variation of approx.1 micron. Low-cost, replicated segment ROC variations are estimated to be almost 1 mm, necessitating a method for segment ROC adjustment & matching. A mechanical architecture has been designed that allows segment ROC to be adjusted up to 400 microns while introducing a minimum figure error, allowing segment-to-segment ROC matching. A key feature of the architecture is the unique back profile of the mirror segments. The back profile of the mirror was developed with shape optimization in MSC.Nastran(TradeMark) using optical performance response equations written with SigFit. A candidate back profile was generated which minimized ROC-adjustment-induced surface error while meeting the constraints imposed by the fabrication method. Keywords: optimization, radius of curvature, Pyrex spherical mirror, Sigfit
Spherical primary optical telescope (SPOT) segments
NASA Astrophysics Data System (ADS)
Hall, Christopher; Hagopian, John; DeMarco, Michael
2012-09-01
The spherical primary optical telescope (SPOT) project is an internal research and development program at NASA Goddard Space Flight Center. The goals of the program are to develop a robust and cost effective way to manufacture spherical mirror segments and demonstrate a new wavefront sensing approach for continuous phasing across the segmented primary. This paper focuses on the fabrication of the mirror segments. Significant cost savings were achieved through the design, since it allowed the mirror segments to be cast rather than machined from a glass blank. Casting was followed by conventional figuring at Goddard Space Flight Center. After polishing, the mirror segments were mounted to their composite assemblies. QED Technologies used magnetorheological finishing (MRF®) for the final figuring. The MRF process polished the mirrors while they were mounted to their composite assemblies. Each assembly included several magnetic invar plugs that extended to within an inch of the face of the mirror. As part of this project, the interaction between the MRF magnetic field and invar plugs was evaluated. By properly selecting the polishing conditions, MRF was able to significantly improve the figure of the mounted segments. The final MRF figuring demonstrates that mirrors, in the mounted configuration, can be polished and tested to specification. There are significant process capability advantes due to polishing and testing the optics in their final, end-use assembled state.
Spherical Primary Optical Telescope (SPOT) Segment Fabrication
2010-06-07
of Pyrex. One mirror (segment) was figured at GSFC and final figured at QED using Magnetorheological Finishing . Two other segments are in process...point) have been cast • Segment 1 was figured at GSFC completed at QED using magnetorheological finishing (MRF) • New GSFC figuring facility brought on
NASA Technical Reports Server (NTRS)
Feinberg, Lee D.; Hagopian, John; Budinoff, Jason; Dean, Bruce; Howard, Joe
2004-01-01
This paper summarizes efforts underway at the Goddard Space Flight Center to demonstrate a new type of space telescope architecture that builds on the rigid segmented telescope heritage of the James Webb Space Telescope but that solves several key challenges for future space telescopes. The architecture is based on a cost-effective segmented spherical primary mirror combined with a unique wavefront sensing and control system that allows for continuous phasing of the primary mirror. The segmented spherical primary allows for cost-effective 3-meter class (e.g., Midex and Discovery) missions as well as enables 30-meter telescope solutions that can be manufactured in a reasonable amount of time and for a reasonable amount of money. The continuous wavefront sensing and control architecture enables missions in low-earth-orbit and missions that do not require expensive stable structures and thermal control systems. For the 30-meter class applications, the paper discusses considerations for assembling and testing the telescopes in space. The paper also summarizes the scientific and technological roadmap for the architecture and also gives an overview of technology development, design studies, and testbed activities underway to demonstrate its feasibility.
NASA Technical Reports Server (NTRS)
Feinberg, Lee; Hagopian, John; Budinoff, Jason; Dean, Bruce; Howard, Joe
2005-01-01
This paper summarizes efforts underway at the Goddard Space Flight Center to demonstrate a new type of space telescope architecture that builds on the rigid, segmented telescope heritage of the James Webb Space Telescope but that solves several key challenges for future space telescopes. The architecture is based on a cost-effective segmented spherical primary mirror combined with a unique wavefront sensing and control system that allows for continuous phasing of the primary mirror. The segmented spherical primary allows for cost-effective 3-meter class (eg, Midex and Discovery) missions as well as enables 30-meter telescope solutions that can be manufactured in a reasonable amount of time and for a reasonable amount of money. The continuous wavefront sensing and control architecture enables missions in low-earth-orbit and missions that do not require expensive stable structures and thermal control systems. For the 30-meter class applications, the paper discusses considerations for assembling and testing the telescopes in space. The paper also summarizes the scientific and technological roadmap for the architecture and also gives an overview of technology development, design studies, and testbed activities underway to demonstrate it s feasibility.
Precision Linear Actuators for the Spherical Primary Optical Telescope Demonstration Mirror
NASA Technical Reports Server (NTRS)
Budinoff, Jason; Pfenning, David
2006-01-01
The Spherical Primary Optical Telescope (SPOT) is an ongoing research effort at Goddard Space Flight Center developing wavefront sensing and control architectures for future space telescopes. The 03.5-m SPOT telescope primary mirror is comprise9 of six 0.86-m hexagonal mirror segments arranged in a single ring, with the central segment missing. The mirror segments are designed for laboratory use and are not lightweighted to reduce cost. Each primary mirror segment is actuated and has tip, tilt, and piston rigid-body motions. Additionally, the radius of curvature of each mirror segment may be varied mechanically. To provide these degrees of freedom, the SPOT mirror segment assembly requires linear actuators capable of
Development and performance of Hobby-Eberly Telescope 11-m segmented mirror
NASA Astrophysics Data System (ADS)
Krabbendam, Victor L.; Sebring, Thomas A.; Ray, Frank B.; Fowler, James R.
1998-08-01
The Hobby Eberly Telescope features a unique eleven-meter spherical primary mirror consisting of a single steel truss populated with 91 Zerodur(superscript TM) mirror segments. The 1 meter hexagonal segments are fabricated to 0.033 micron RMS spherical surfaces with matched radii to 0.5 mm. Silver coatings are applied to meet reflectance criteria for wavelengths from 0.35 to 2.5 micron. To support the primary spectroscopic uses of the telescope the mirror must provide a 0.52 arc sec FWHM point spread function. Mirror segments are co-aligned to within 0.0625 ar sec and held to 25 microns of piston envelope using a segment positioning system that consists of 273 actuators (3 per mirror), a distributed population of controllers, and custom developed software. A common path polarization shearing interferometer was developed to provide alignment sensing of the entire array from the primary mirror's center of curvature. Performance of the array is being tested with an emphasis on alignment stability. Distributed temperature measurements throughout the truss are correlated to pointing variances of the individual mirror segments over extended periods of time. Results are very encouraging and indicate that this mirror system approach will prove to be a cost-effective solution for large optical collecting apertures.
Hatt, Mathieu; Laurent, Baptiste; Fayad, Hadi; Jaouen, Vincent; Visvikis, Dimitris; Le Rest, Catherine Cheze
2018-04-01
Sphericity has been proposed as a parameter for characterizing PET tumour volumes, with complementary prognostic value with respect to SUV and volume in both head and neck cancer and lung cancer. The objective of the present study was to investigate its dependency on tumour delineation and the resulting impact on its prognostic value. Five segmentation methods were considered: two thresholds (40% and 50% of SUV max ), ant colony optimization, fuzzy locally adaptive Bayesian (FLAB), and gradient-aided region-based active contour. The accuracy of each method in extracting sphericity was evaluated using a dataset of 176 simulated, phantom and clinical PET images of tumours with associated ground truth. The prognostic value of sphericity and its complementary value with respect to volume for each segmentation method was evaluated in a cohort of 87 patients with stage II/III lung cancer. Volume and associated sphericity values were dependent on the segmentation method. The correlation between segmentation accuracy and sphericity error was moderate (|ρ| from 0.24 to 0.57). The accuracy in measuring sphericity was not dependent on volume (|ρ| < 0.4). In the patients with lung cancer, sphericity had prognostic value, although lower than that of volume, except for that derived using FLAB for which when combined with volume showed a small improvement over volume alone (hazard ratio 2.67, compared with 2.5). Substantial differences in patient prognosis stratification were observed depending on the segmentation method used. Tumour functional sphericity was found to be dependent on the segmentation method, although the accuracy in retrieving the true sphericity was not dependent on tumour volume. In addition, even accurate segmentation can lead to an inaccurate sphericity value, and vice versa. Sphericity had similar or lower prognostic value than volume alone in the patients with lung cancer, except when determined using the FLAB method for which there was a small improvement in stratification when the parameters were combined.
Self-assembling segmented coiled tubing
Raymond, David W.
2016-09-27
Self-assembling segmented coiled tubing is a concept that allows the strength of thick-wall rigid pipe, and the flexibility of thin-wall tubing, to be realized in a single design. The primary use is for a drillstring tubular, but it has potential for other applications requiring transmission of mechanical loads (forces and torques) through an initially coiled tubular. The concept uses a spring-loaded spherical `ball-and-socket` type joint to interconnect two or more short, rigid segments of pipe. Use of an optional snap ring allows the joint to be permanently made, in a `self-assembling` manner.
NASA Astrophysics Data System (ADS)
West, S. C.; Burge, J. H.; Cuerden, B.; Davison, W.; Hagen, J.; Martin, H. M.; Tuell, M. T.; Zhao, C.; Zobrist, T.
2010-07-01
The Giant Magellan Telescope has a 25 meter f/0.7 near-parabolic primary mirror constructed from seven 8.4 meter diameter segments. Several aspects of the interferometric optical test used to guide polishing of the six off-axis segments go beyond the demonstrated state of the art in optical testing. The null corrector is created from two obliquelyilluminated spherical mirrors combined with a computer-generated hologram (the measurement hologram). The larger mirror is 3.75 m in diameter and is supported at the top of a test tower, 23.5 m above the GMT segment. Its size rules out a direct validation of the wavefront produced by the null corrector. We can, however, use a reference hologram placed at an intermediate focus between the two spherical mirrors to measure the wavefront produced by the measurement hologram and the first mirror. This reference hologram is aligned to match the wavefront and thereby becomes the alignment reference for the rest of the system. The position and orientation of the reference hologram, the 3.75 m mirror and the GMT segment are measured with a dedicated laser tracker, leading to an alignment accuracy of about 100 microns over the 24 m dimensions of the test. In addition to the interferometer that measures the GMT segment, a separate interferometer at the center of curvature of the 3.75 m sphere monitors its figure simultaneously with the GMT measurement, allowing active correction and compensation for residual errors. We describe the details of the design, alignment, and use of this unique off-axis optical test.
Qiu, Cheng-Wei; Hu, Li; Zhang, Baile; Wu, Bae-Ian; Johnson, Steven G; Joannopoulos, John D
2009-08-03
Two novel classes of spherical invisibility cloaks based on nonlinear transformation have been studied. The cloaking characteristics are presented by segmenting the nonlinear transformation based spherical cloak into concentric isotropic homogeneous coatings. Detailed investigations of the optimal discretization (e.g., thickness control of each layer, nonlinear factor, etc.) are presented for both linear and nonlinear spherical cloaks and their effects on invisibility performance are also discussed. The cloaking properties and our choice of optimal segmentation are verified by the numerical simulation of not only near-field electric-field distribution but also the far-field radar cross section (RCS).
Synthesis of hollow spherical calcium phosphate nanoparticles using polymeric nanotemplates
NASA Astrophysics Data System (ADS)
Tjandra, Wiliana; Ravi, Palaniswamy; Yao, Jia; Tam, Kam C.
2006-12-01
Poly(methylmethacrylate)-block-poly(methacrylic acid) (PMMA-b-PMAA) copolymer was synthesized by an atom transfer radical polymerization (ATRP) technique. The block copolymer was employed as a template for the controlled precipitation of calcium phosphate from aqueous solution at different pH values. A Ca2+ ion selective electrode was used to study the interactions between Ca2+ ions and the polymer, which indicated a possible weak interaction between Ca2+ and un-ionized MAA segments at pH~4.0 in addition to electrostatic interaction between Ca2+ and ionized MAA segments at higher pH. An interesting structure representing that of a superstructure consisting of hybrid nano-filaments was observed by the transmission electron microscope at pH~4.0. The filaments originated from a core of similar size to primary polymer aggregates, suggesting that cooperative interactions at a local level between dissolving calcium phosphate clusters and disassembling polymer segments are responsible for the secondary growth process. A hollow spherical morphology was obtained at pH~7.0 and 9.0. Such calcium phosphate/polymer monohybrids with complex morphologies are interesting and might be useful as novel drug delivery carriers, ceramics precursors, reinforcing fillers or biomedical implants.
Progress in manufacturing the first 8.4 m off-axis segment for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Burge, J. H.; Cuerden, B.; Davison, W. B.; Kingsley, J. S.; Kittrell, W. C.; Lutz, R. D.; Miller, S. M.; Zhao, C.; Zobrist, T.
2008-07-01
The first of the 8.4 m off-axis segments for the primary mirror of the Giant Magellan Telescope is being manufactured at the Steward Observatory Mirror Lab. In addition to the manufacture of the segment, this project includes the development of a complete facility to make and measure all seven segments. We have installed a new 28 m test tower and designed a set of measurements to guide the fabrication and qualify the finished segments. The first test, a laser-tracker measurement of the ground surface, is operational. The principal optical test is a full-aperture interferometric test with a null corrector that includes a 3.75 m spherical mirror, a smaller sphere, and a computer-generated hologram. We have also designed a scanning pentaprism test to validate the measurement of low-order aberrations. The first segment has been cast and generated, and is in the process of loose-abrasive grinding.
Measurement of aspheric mirror segments using Fizeau interferometry with CGH correction
NASA Astrophysics Data System (ADS)
Burge, James H.; Zhao, Chunyu; Dubin, Matt
2010-07-01
Large aspheric primary mirrors are proposed that use hundreds segments that all must be aligned and phased to approximate the desired continuous mirror. We present a method of measuring these concave segments with a Fizeau interferometer where a spherical convex reference surface is held a few millimeters from the aspheric segment. The aspheric shape is accommodated by a small computer generated hologram (CGH). Different segments are measured by replacing the CGH. As a Fizeau test, nearly all of the optical elements and air spaces are common to both the measurement and reference wavefront, so the sensitivities are not tight. Also, since the reference surface of the test plate is common to all tests, this system achieves excellent control for the radius of curvature variation from one part to another. This paper describes the test system design and analysis for such a test, and presents data from a similar 1.4-m test performed at the University of Arizona.
Wide-angle flat field telescope
NASA Technical Reports Server (NTRS)
Hallam, K. L.; Howell, B. J.; Wilson, M. E.
1986-01-01
Described is an unobscured three mirror wide angle telescopic imaging system comprised of an input baffle which provides a 20 deg (Y axis) x 30 deg (X axis) field of view, a primary mirror having a convex spherical surface, a secondary mirror having a concave ellipsoidal reflecting surface, a tertiary mirror having a concave spherical reflecting surface. The mirrors comprise mirror elements which are offset segments of parent mirrors whose axes and vertices commonly lie on the system's optical axis. An iris diaphragm forming an aperture stop is located between the secondary and tertiary mirror with its center also being coincident with the optical axis and being further located at the beam waist of input light beams reflected from the primary and secondary mirror surfaces. At the system focus following the tertiary mirror is located a flat detector which may be, for example, a TV imaging tube or a photographic film. When desirable, a spectral transmission filter is placed in front of the detector in close proximity thereto.
Alp, Murat; Cucinotta, Francis A.
2017-01-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (>100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. PMID:28554507
NASA Astrophysics Data System (ADS)
Alp, Murat; Cucinotta, Francis A.
2017-05-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100 μm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3He and 12C particles at energies corresponding to a distance of 1 cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch.
Alp, Murat; Cucinotta, Francis A
2017-05-01
Changes to cognition, including memory, following radiation exposure are a concern for cosmic ray exposures to astronauts and in Hadron therapy with proton and heavy ion beams. The purpose of the present work is to develop computational methods to evaluate microscopic energy deposition (ED) in volumes representative of neuron cell structures, including segments of dendrites and spines, using a stochastic track structure model. A challenge for biophysical models of neuronal damage is the large sizes (> 100µm) and variability in volumes of possible dendritic segments and pre-synaptic elements (spines and filopodia). We consider cylindrical and spherical microscopic volumes of varying geometric parameters and aspect ratios from 0.5 to 5 irradiated by protons, and 3 He and 12 C particles at energies corresponding to a distance of 1cm to the Bragg peak, which represent particles of interest in Hadron therapy as well as space radiation exposure. We investigate the optimal axis length of dendritic segments to evaluate microscopic ED and hit probabilities along the dendritic branches at a given macroscopic dose. Because of large computation times to analyze ED in volumes of varying sizes, we developed an analytical method to find the mean primary dose in spheres that can guide numerical methods to find the primary dose distribution for cylinders. Considering cylindrical segments of varying aspect ratio at constant volume, we assess the chord length distribution, mean number of hits and ED profiles by primary particles and secondary electrons (δ-rays). For biophysical modeling applications, segments on dendritic branches are proposed to have equal diameters and axes lengths along the varying diameter of a dendritic branch. Copyright © 2017. Published by Elsevier Ltd.
Method for preparing spherical thermoplastic particles of uniform size
Day, J.R.
1975-11-17
Spherical particles of thermoplastic material of virtually uniform roundness and diameter are prepared by cutting monofilaments of a selected diameter into rod-like segments of a selected uniform length which are then heated in a viscous liquid to effect the formation of the spherical particles.
Production of primary mirror segments for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Allen, R. G.; Burge, J. H.; Davis, J. M.; Davison, W. B.; Johns, M.; Kim, D. W.; Kingsley, J. S.; Law, K.; Lutz, R. D.; Strittmatter, P. A.; Su, P.; Tuell, M. T.; West, S. C.; Zhou, P.
2014-07-01
Segment production for the Giant Magellan Telescope is well underway, with the off-axis Segment 1 completed, off-axis Segments 2 and 3 already cast, and mold construction in progress for the casting of Segment 4, the center segment. All equipment and techniques required for segment fabrication and testing have been demonstrated in the manufacture of Segment 1. The equipment includes a 28 m test tower that incorporates four independent measurements of the segment's figure and geometry. The interferometric test uses a large asymmetric null corrector with three elements including a 3.75 m spherical mirror and a computer-generated hologram. For independent verification of the large-scale segment shape, we use a scanning pentaprism test that exploits the natural geometry of the telescope to focus collimated light to a point. The Software Configurable Optical Test System, loosely based on the Hartmann test, measures slope errors to submicroradian accuracy at high resolution over the full aperture. An enhanced laser tracker system guides the figuring through grinding and initial polishing. All measurements agree within the expected uncertainties, including three independent measurements of radius of curvature that agree within 0.3 mm. Segment 1 was polished using a 1.2 m stressed lap for smoothing and large-scale figuring, and a set of smaller passive rigid-conformal laps on an orbital polisher for deterministic small-scale figuring. For the remaining segments, the Mirror Lab is building a smaller, orbital stressed lap to combine the smoothing capability with deterministic figuring.
Shape-driven 3D segmentation using spherical wavelets.
Nain, Delphine; Haker, Steven; Bobick, Aaron; Tannenbaum, Allen
2006-01-01
This paper presents a novel active surface segmentation algorithm using a multiscale shape representation and prior. We define a parametric model of a surface using spherical wavelet functions and learn a prior probability distribution over the wavelet coefficients to model shape variations at different scales and spatial locations in a training set. Based on this representation, we derive a parametric active surface evolution using the multiscale prior coefficients as parameters for our optimization procedure to naturally include the prior in the segmentation framework. Additionally, the optimization method can be applied in a coarse-to-fine manner. We apply our algorithm to the segmentation of brain caudate nucleus, of interest in the study of schizophrenia. Our validation shows our algorithm is computationally efficient and outperforms the Active Shape Model algorithm by capturing finer shape details.
Hemispherical map for the human brain cortex
NASA Astrophysics Data System (ADS)
Tosun, Duygu; Prince, Jerry L.
2001-07-01
Understanding the function of the human brain cortex is a primary goal in human brain mapping. Methods to unfold and flatten the cortical surface for visualization and measurement have been described in previous literature; but comparison across multiple subjects is still difficult because of the lack of a standard mapping technique. We describe a new approach that maps each hemisphere of the cortex to a portion of a sphere in a standard way, making comparison of anatomy and function across different subjects possible. Starting with a three-dimensional magnetic resonance image of the brain, the cortex is segmented and represented as a triangle mesh. Defining a cut around the corpus collosum identifies the left and right hemispheres. Together, the two hemispheres are mapped to the complex plane using a conformal mapping technique. A Mobius transformation, which is conformal, is used to transform the points on the complex plane so that a projective transformation maps each brain hemisphere onto a spherical segment comprising a sphere with a cap removed. We determined the best size of the spherical cap by minimizing the relative area distortion between hemispherical maps and original cortical surfaces. The relative area distortion between the hemispherical maps and the original cortical surfaces for fifteen human brains is analyzed.
Shape-Driven 3D Segmentation Using Spherical Wavelets
Nain, Delphine; Haker, Steven; Bobick, Aaron; Tannenbaum, Allen
2013-01-01
This paper presents a novel active surface segmentation algorithm using a multiscale shape representation and prior. We define a parametric model of a surface using spherical wavelet functions and learn a prior probability distribution over the wavelet coefficients to model shape variations at different scales and spatial locations in a training set. Based on this representation, we derive a parametric active surface evolution using the multiscale prior coefficients as parameters for our optimization procedure to naturally include the prior in the segmentation framework. Additionally, the optimization method can be applied in a coarse-to-fine manner. We apply our algorithm to the segmentation of brain caudate nucleus, of interest in the study of schizophrenia. Our validation shows our algorithm is computationally efficient and outperforms the Active Shape Model algorithm by capturing finer shape details. PMID:17354875
Marko, John F.
2011-01-01
Scaling laws for Gauss linking number Ca and writhing number Wr for spherically confined flexible polymers with thermally fluctuating topology are analyzed. For ideal (phantom) polymers each of N segments of length unity confined to a spherical pore of radius R there are two scaling regimes: for sufficiently weak confinement (R ⪢ N1/3) each chain has |Wr| ≈ N1/2, and each pair of chains has average |Ca| ≈ N/R3/2; alternately for sufficiently tight confinement (N1/3 ⪢ R), |Wr| ≈ |CA| ≈ N/R3/2. Adding segment-segment avoidance modifies this result: for n chains with excluded volume interactions |Ca| ≈ (N/n)1/2f(ϕ) where f is a scaling function that depends approximately linearly on the segment concentration ϕ = nN/R3. Scaling results for writhe are used to estimate the maximum writhe of a polymer; this is demonstrated to be realizable through a writhing instability that occurs for a polymer which is able to change knotting topology and which is subject to an applied torque. Finally, scaling results for linking are used to estimate bounds on the entanglement complexity of long chromosomal DNA molecules inside cells, and to show how “lengthwise” chromosome condensation can suppress DNA entanglement. PMID:21686050
A multiball read-out for the spherical proportional counter
NASA Astrophysics Data System (ADS)
Giganon, A.; Giomataris, I.; Gros, M.; Katsioulas, I.; Navick, X. F.; Tsiledakis, G.; Savvidis, I.; Dastgheibi-Fard, A.; Brossard, A.
2017-12-01
We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high-pressure operations. We have developed a multi-ball read-out system which consists of several balls placed at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case, the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.
Radiation absorbed dose to bladder walls from positron emitters in the bladder content.
Powell, G F; Chen, C T
1987-01-01
A method to calculate absorbed doses at depths in the walls of a static spherical bladder from a positron emitter in the bladder content has been developed. The beta ray dose component is calculated for a spherical model by employing the solutions to the integration of Loevinger and Bochkarev point source functions over line segments and a line segment source array technique. The gamma ray dose is determined using the specific gamma ray constant. As an example, absorbed radiation doses to the bladder walls from F-18 in the bladder content are presented for static spherical bladder models having radii of 2.0 and 3.5 cm, respectively. Experiments with ultra-thin thermoluminescent dosimeters (TLD's) were performed to verify the results of the calculations. Good agreement between TLD measurements and calculations was obtained.
NASA Astrophysics Data System (ADS)
Gallivanone, F.; Interlenghi, M.; Canervari, C.; Castiglioni, I.
2016-01-01
18F-Fluorodeoxyglucose (18F-FDG) Positron Emission Tomography (PET) is a standard functional diagnostic technique to in vivo image cancer. Different quantitative paramters can be extracted from PET images and used as in vivo cancer biomarkers. Between PET biomarkers Metabolic Tumor Volume (MTV) has gained an important role in particular considering the development of patient-personalized radiotherapy treatment for non-homogeneous dose delivery. Different imaging processing methods have been developed to define MTV. The different proposed PET segmentation strategies were validated in ideal condition (e.g. in spherical objects with uniform radioactivity concentration), while the majority of cancer lesions doesn't fulfill these requirements. In this context, this work has a twofold objective: 1) to implement and optimize a fully automatic, threshold-based segmentation method for the estimation of MTV, feasible in clinical practice 2) to develop a strategy to obtain anthropomorphic phantoms, including non-spherical and non-uniform objects, miming realistic oncological patient conditions. The developed PET segmentation algorithm combines an automatic threshold-based algorithm for the definition of MTV and a k-means clustering algorithm for the estimation of the background. The method is based on parameters always available in clinical studies and was calibrated using NEMA IQ Phantom. Validation of the method was performed both in ideal (e.g. in spherical objects with uniform radioactivity concentration) and non-ideal (e.g. in non-spherical objects with a non-uniform radioactivity concentration) conditions. The strategy to obtain a phantom with synthetic realistic lesions (e.g. with irregular shape and a non-homogeneous uptake) consisted into the combined use of standard anthropomorphic phantoms commercially and irregular molds generated using 3D printer technology and filled with a radioactive chromatic alginate. The proposed segmentation algorithm was feasible in a clinical context and showed a good accuracy both in ideal and in realistic conditions.
An active co-phasing imaging testbed with segmented mirrors
NASA Astrophysics Data System (ADS)
Zhao, Weirui; Cao, Genrui
2011-06-01
An active co-phasing imaging testbed with high accurate optical adjustment and control in nanometer scale was set up to validate the algorithms of piston and tip-tilt error sensing and real-time adjusting. Modularization design was adopted. The primary mirror was spherical and divided into three sub-mirrors. One of them was fixed and worked as reference segment, the others were adjustable respectively related to the fixed segment in three freedoms (piston, tip and tilt) by using sensitive micro-displacement actuators in the range of 15mm with a resolution of 3nm. The method of twodimension dispersed fringe analysis was used to sense the piston error between the adjacent segments in the range of 200μm with a repeatability of 2nm. And the tip-tilt error was gained with the method of centroid sensing. Co-phasing image could be realized by correcting the errors measured above with the sensitive micro-displacement actuators driven by a computer. The process of co-phasing error sensing and correcting could be monitored in real time by a scrutiny module set in this testbed. A FISBA interferometer was introduced to evaluate the co-phasing performance, and finally a total residual surface error of about 50nm rms was achieved.
Local-area simulations of rotating compressible convection and associated mean flows
NASA Technical Reports Server (NTRS)
Hurlburt, Neal E.; Brummell, N. H.; Toomre, Juri
1995-01-01
The dynamics of compressible convection within a curved local segment of a rotating spherical shell are considered in relation to the turbulent redistribution of angular momentum within the solar convection zone. Current supercomputers permit fully turbulent flows to be considered within the restricted geometry of local area models. By considering motions in a curvilinear geometry in which the Coriolos parameters vary with latitude, Rossby waves which couple with the turbulent convection are thought of as being possible. Simulations of rotating convection are presented in such a curved local segment of a spherical shell using a newly developed, sixth-order accurate code based on compact finite differences.
NASA Astrophysics Data System (ADS)
Garg, Ishita; Karwoski, Ronald A.; Camp, Jon J.; Bartholmai, Brian J.; Robb, Richard A.
2005-04-01
Chronic obstructive pulmonary diseases (COPD) are debilitating conditions of the lung and are the fourth leading cause of death in the United States. Early diagnosis is critical for timely intervention and effective treatment. The ability to quantify particular imaging features of specific pathology and accurately assess progression or response to treatment with current imaging tools is relatively poor. The goal of this project was to develop automated segmentation techniques that would be clinically useful as computer assisted diagnostic tools for COPD. The lungs were segmented using an optimized segmentation threshold and the trachea was segmented using a fixed threshold characteristic of air. The segmented images were smoothed by a morphological close operation using spherical elements of different sizes. The results were compared to other segmentation approaches using an optimized threshold to segment the trachea. Comparison of the segmentation results from 10 datasets showed that the method of trachea segmentation using a fixed air threshold followed by morphological closing with spherical element of size 23x23x5 yielded the best results. Inclusion of greater number of pulmonary vessels in the lung volume is important for the development of computer assisted diagnostic tools because the physiological changes of COPD can result in quantifiable anatomic changes in pulmonary vessels. Using a fixed threshold to segment the trachea removed airways from the lungs to a better extent as compared to using an optimized threshold. Preliminary measurements gathered from patient"s CT scans suggest that segmented images can be used for accurate analysis of total lung volume and volumes of regional lung parenchyma. Additionally, reproducible segmentation allows for quantification of specific pathologic features, such as lower intensity pixels, which are characteristic of abnormal air spaces in diseases like emphysema.
NASA Astrophysics Data System (ADS)
Vinogradov, E. A.; Gridin, S. A.; Golovanov, V. I.; Danilenko, A. A.; Bulatov, E. D.
1989-01-01
A system capable of focusing monochromatic microwave radiation with a spherical or planar wavefront into a straight line segment is designed. The system consists of zone elements made with numerically controlled machine tools. The study of the image obtained revealed that the width of the formed local segment is close to the diffraction limit.
Efficiency of geometric designs of flexible solar panels: mathematical simulation
NASA Astrophysics Data System (ADS)
Marciniak, Malgorzata; Hassebo, Yasser; Enriquez-Torres, Delfino; Serey-Roman, Maria Ignacia
2017-09-01
The purpose of this study is to analyze various surfaces of flexible solar panels and compare them to the traditional at panels mathematically. We evaluated the efficiency based on the integral formulas that involve flux. We performed calculations for flat panels with different positions, a cylindrical panel, conical panels with various opening angles and segments of a spherical panel. Our results indicate that the best efficiency per unit area belongs to particular segments of spherically-shaped panels. In addition, we calculated the optimal opening angle of a cone-shaped panel that maximizes the annual accumulation of the sun radiation per unit area. The considered shapes are presented below with a suggestion for connections of the cells.
3D Echo Pilot Study of Geometric Left Ventricular Changes after Acute Myocardial Infarction
Vieira, Marcelo Luiz Campos; Oliveira, Wercules Antonio; Cordovil, Adriana; Rodrigues, Ana Clara Tude; Mônaco, Cláudia Gianini; Afonso, Tânia; Lira Filho, Edgar Bezerra; Perin, Marco; Fischer, Cláudio Henrique; Morhy, Samira Saady
2013-01-01
Background Left ventricular remodeling (LVR) after AMI characterizes a factor of poor prognosis. There is little information in the literature on the LVR analyzed with three-dimensional echocardiography (3D ECHO). Objective To analyze, with 3D ECHO, the geometric and volumetric modifications of the left ventricle (VE) six months after AMI in patients subjected to percutaneous primary treatment. Methods Prospective study with 3D ECHO of 21 subjects (16 men, 56 ± 12 years-old), affected by AMI with ST segment elevation. The morphological and functional analysis (LV) with 3D ECHO (volumes, LVEF, 3D sphericity index) was carried out up to seven days and six months after the AMI. The LVR was considered for increase > 15% of the end diastolic volume of the LV (LVEDV) six months after the AMI, compared to the LVEDV up to seven days from the event. Results Eight (38%) patients have presented LVR. Echocardiographic measurements (n = 21 patients): I- up to seven days after the AMI: 1- LVEDV: 92.3 ± 22.3 mL; 2- LVEF: 0.51 ± 0.01; 3- sphericity index: 0.38 ± 0.05; II- after six months: 1- LVEDV: 107.3 ± 26.8 mL; 2- LVEF: 0.59 ± 0.01; 3- sphericity index: 0.31 ± 0.05. Correlation coefficient (r) between the sphericity index up to seven days after the AMI and the LVEDV at six months (n = 8) after the AMI: r: 0.74, p = 0.0007; (r) between the sphericity index six months after the AMI and the LVEDV at six months after the AMI: r: 0.85, p < 0.0001. Conclusion In this series, LVR has been observed in 38% of the patients six months after the AMI. The three-dimensional sphericity index has been associated to the occurrence of LVR. PMID:23740401
Biomechanical evaluation of a spherical lumbar interbody device at varying levels of subsidence.
Rundell, Steven A; Isaza, Jorge E; Kurtz, Steven M
2011-01-01
Ulf Fernström implanted stainless steel ball bearings following discectomy, or for painful disc disease, and termed this procedure disc arthroplasty. Today, spherical interbody spacers are clinically available, but there is a paucity of associated biomechanical testing. The primary objective of the current study was to evaluate the biomechanics of a spherical interbody implant. It was hypothesized that implantation of a spherical interbody implant, with combined subsidence into the vertebral bodies, would result in similar ranges of motion (RoM) and facet contact forces (FCFs) when compared with an intact condition. A secondary objective of this study was to determine the effect of using a polyetheretherketone (PEEK) versus a cobalt chrome (CoCr) implant on vertebral body strains. We hypothesized that the material selection would have a negligible effect on vertebral body strains since both materials have elastic moduli substantially greater than the annulus. A finite element model of L3-L4 was created and validated by use of ROM, disc pressure, and bony strain from previously published data. Virtual implantation of a spherical interbody device was performed with 0, 2, and 4 mm of subsidence. The model was exercised in compression, flexion, extension, axial rotation, and lateral bending. The ROM, vertebral body effective (von Mises) strain, and FCFs were reported. Implantation of a PEEK implant resulted in slightly lower strain maxima when compared with a CoCr implant. For both materials, the peak strain experienced by the underlying bone was reduced with increasing subsidence. All levels of subsidence resulted in ROM and FCFs similar to the intact model. The results suggest that a simple spherical implant design is able to maintain segmental ROM and provide minimal differences in FCFs. Large areas of von Mises strain maxima were generated in the bone adjacent to the implant regardless of whether the implant was PEEK or CoCr.
Method and apparatus for uniformly concentrating solar flux for photovoltaic applications
Jorgensen, Gary J.; Carasso, Meir; Wendelin, Timothy J.; Lewandowski, Allan A.
1992-01-01
A dish reflector and method for concentrating moderate solar flux uniformly on a target plane on a solar cell array, the dish having a stepped reflective surface that is characterized by a plurality of ring-like segments arranged about a common axis, and each segment having a concave spherical configuration.
Eck, Simon; Wörz, Stefan; Müller-Ott, Katharina; Hahn, Matthias; Biesdorf, Andreas; Schotta, Gunnar; Rippe, Karsten; Rohr, Karl
2016-08-01
The genome is partitioned into regions of euchromatin and heterochromatin. The organization of heterochromatin is important for the regulation of cellular processes such as chromosome segregation and gene silencing, and their misregulation is linked to cancer and other diseases. We present a model-based approach for automatic 3D segmentation and 3D shape analysis of heterochromatin foci from 3D confocal light microscopy images. Our approach employs a novel 3D intensity model based on spherical harmonics, which analytically describes the shape and intensities of the foci. The model parameters are determined by fitting the model to the image intensities using least-squares minimization. To characterize the 3D shape of the foci, we exploit the computed spherical harmonics coefficients and determine a shape descriptor. We applied our approach to 3D synthetic image data as well as real 3D static and real 3D time-lapse microscopy images, and compared the performance with that of previous approaches. It turned out that our approach yields accurate 3D segmentation results and performs better than previous approaches. We also show that our approach can be used for quantifying 3D shape differences of heterochromatin foci. Copyright © 2016 Elsevier B.V. All rights reserved.
The glass spherical hollow orbital implant: a prospective study.
Stephen, B E
1999-06-01
Various types of orbital implants are in use in the rehabilitation of anophthalmic patients. The latest is the expensive hydroxyapatite implant. The study objective was to evaluate the effectiveness of low cost glass spherical hollow implants, as primary and secondary implants. St Michaels and Frazer Private Hospitals, Colombo. 65 patients had glass sphere orbital implants between 1987 and 1995; 51 primary (evisceration 46, enucleation 5) and 14 secondary (evisceration 2, enucleation 12). At 9 to 12 months follow up, patients were evaluated for mobility of implant, prosthesis mobility, lid sulcus deformity, cosmetic results and complications. Primary glass spherical hollow implants provide excellent mobility of the implant (92%), cosmesis (88%), prosthesis mobility (67%), with a low rate of complications (9.5%). Results of primary implant was superior to that of secondary (p < 0.001). Excellent results were obtained with spherical glass spheres as primary implants following evisceration.
Virtual endoscopy using spherical QuickTime-VR panorama views.
Tiede, Ulf; von Sternberg-Gospos, Norman; Steiner, Paul; Höhne, Karl Heinz
2002-01-01
Virtual endoscopy needs some precomputation of the data (segmentation, path finding) before the diagnostic process can take place. We propose a method that precomputes multinode spherical panorama movies using Quick-Time VR. This technique allows almost the same navigation and visualization capabilities as a real endoscopic procedure, a significant reduction of interaction input is achieved and the movie represents a document of the procedure.
Multiscale 3-D shape representation and segmentation using spherical wavelets.
Nain, Delphine; Haker, Steven; Bobick, Aaron; Tannenbaum, Allen
2007-04-01
This paper presents a novel multiscale shape representation and segmentation algorithm based on the spherical wavelet transform. This work is motivated by the need to compactly and accurately encode variations at multiple scales in the shape representation in order to drive the segmentation and shape analysis of deep brain structures, such as the caudate nucleus or the hippocampus. Our proposed shape representation can be optimized to compactly encode shape variations in a population at the needed scale and spatial locations, enabling the construction of more descriptive, nonglobal, nonuniform shape probability priors to be included in the segmentation and shape analysis framework. In particular, this representation addresses the shortcomings of techniques that learn a global shape prior at a single scale of analysis and cannot represent fine, local variations in a population of shapes in the presence of a limited dataset. Specifically, our technique defines a multiscale parametric model of surfaces belonging to the same population using a compact set of spherical wavelets targeted to that population. We further refine the shape representation by separating into groups wavelet coefficients that describe independent global and/or local biological variations in the population, using spectral graph partitioning. We then learn a prior probability distribution induced over each group to explicitly encode these variations at different scales and spatial locations. Based on this representation, we derive a parametric active surface evolution using the multiscale prior coefficients as parameters for our optimization procedure to naturally include the prior for segmentation. Additionally, the optimization method can be applied in a coarse-to-fine manner. We apply our algorithm to two different brain structures, the caudate nucleus and the hippocampus, of interest in the study of schizophrenia. We show: 1) a reconstruction task of a test set to validate the expressiveness of our multiscale prior and 2) a segmentation task. In the reconstruction task, our results show that for a given training set size, our algorithm significantly improves the approximation of shapes in a testing set over the Point Distribution Model, which tends to oversmooth data. In the segmentation task, our validation shows our algorithm is computationally efficient and outperforms the Active Shape Model algorithm, by capturing finer shape details.
Multiscale 3-D Shape Representation and Segmentation Using Spherical Wavelets
Nain, Delphine; Haker, Steven; Bobick, Aaron
2013-01-01
This paper presents a novel multiscale shape representation and segmentation algorithm based on the spherical wavelet transform. This work is motivated by the need to compactly and accurately encode variations at multiple scales in the shape representation in order to drive the segmentation and shape analysis of deep brain structures, such as the caudate nucleus or the hippocampus. Our proposed shape representation can be optimized to compactly encode shape variations in a population at the needed scale and spatial locations, enabling the construction of more descriptive, nonglobal, nonuniform shape probability priors to be included in the segmentation and shape analysis framework. In particular, this representation addresses the shortcomings of techniques that learn a global shape prior at a single scale of analysis and cannot represent fine, local variations in a population of shapes in the presence of a limited dataset. Specifically, our technique defines a multiscale parametric model of surfaces belonging to the same population using a compact set of spherical wavelets targeted to that population. We further refine the shape representation by separating into groups wavelet coefficients that describe independent global and/or local biological variations in the population, using spectral graph partitioning. We then learn a prior probability distribution induced over each group to explicitly encode these variations at different scales and spatial locations. Based on this representation, we derive a parametric active surface evolution using the multiscale prior coefficients as parameters for our optimization procedure to naturally include the prior for segmentation. Additionally, the optimization method can be applied in a coarse-to-fine manner. We apply our algorithm to two different brain structures, the caudate nucleus and the hippocampus, of interest in the study of schizophrenia. We show: 1) a reconstruction task of a test set to validate the expressiveness of our multiscale prior and 2) a segmentation task. In the reconstruction task, our results show that for a given training set size, our algorithm significantly improves the approximation of shapes in a testing set over the Point Distribution Model, which tends to oversmooth data. In the segmentation task, our validation shows our algorithm is computationally efficient and outperforms the Active Shape Model algorithm, by capturing finer shape details. PMID:17427745
Optimal secondary source position in exterior spherical acoustical holophony
NASA Astrophysics Data System (ADS)
Pasqual, A. M.; Martin, V.
2012-02-01
Exterior spherical acoustical holophony is a branch of spatial audio reproduction that deals with the rendering of a given free-field radiation pattern (the primary field) by using a compact spherical loudspeaker array (the secondary source). More precisely, the primary field is known on a spherical surface surrounding the primary and secondary sources and, since the acoustic fields are described in spherical coordinates, they are naturally subjected to spherical harmonic analysis. Besides, the inverse problem of deriving optimal driving signals from a known primary field is ill-posed because the secondary source cannot radiate high-order spherical harmonics efficiently, especially in the low-frequency range. As a consequence, a standard least-squares solution will overload the transducers if the primary field contains such harmonics. Here, this is avoided by discarding the strongly decaying spherical waves, which are identified through inspection of the radiation efficiency curves of the secondary source. However, such an unavoidable regularization procedure increases the least-squares error, which also depends on the position of the secondary source. This paper deals with the above-mentioned questions in the context of far-field directivity reproduction at low and medium frequencies. In particular, an optimal secondary source position is sought, which leads to the lowest reproduction error in the least-squares sense without overloading the transducers. In order to address this issue, a regularization quality factor is introduced to evaluate the amount of regularization required. It is shown that the optimal position improves significantly the holophonic reconstruction and maximizes the regularization quality factor (minimizes the amount of regularization), which is the main general contribution of this paper. Therefore, this factor can also be used as a cost function to obtain the optimal secondary source position.
Adsorption of hairy particles with mobile ligands: Molecular dynamics and density functional study
NASA Astrophysics Data System (ADS)
Borówko, M.; Sokołowski, S.; Staszewski, T.; Pizio, O.
2018-01-01
We study models of hairy nanoparticles in contact with a hard wall. Each particle is built of a spherical core with a number of ligands attached to it and each ligand is composed of several spherical, tangentially jointed segments. The number of segments is the same for all ligands. Particular models differ by the numbers of ligands and of segments per ligand, but the total number of segments is constant. Moreover, our model assumes that the ligands are tethered to the core in such a manner that they can "slide" over the core surface. Using molecular dynamics simulations we investigate the differences in the structure of a system close to the wall. In order to characterize the distribution of the ligands around the core, we have calculated the end-to-end distances of the ligands and the lengths and orientation of the mass dipoles. Additionally, we also employed a density functional approach to obtain the density profiles. We have found that if the number of ligands is not too high, the proposed version of the theory is capable to predict the structure of the system with a reasonable accuracy.
Tirumani, Sree Harsha; Shinagare, Atul B; O'Neill, Ailbhe C; Nishino, Mizuki; Rosenthal, Michael H; Ramaiya, Nikhil H
2016-01-01
To validate estimated tumour volumetry in primary gastric gastrointestinal stromal tumours (GISTs) using semiautomated volumetry. In this IRB-approved retrospective study, we measured the three longest diameters in x, y, z axes on CTs of primary gastric GISTs in 127 consecutive patients (52 women, 75 men, mean age 61 years) at our institute between 2000 and 2013. Segmented volumes (Vsegmented) were obtained using commercial software by two radiologists. Estimate volumes (V1-V6) were obtained using formulae for spheres and ellipsoids. Intra- and interobserver agreement of Vsegmented and agreement of V1-6 with Vsegmented were analysed with concordance correlation coefficients (CCC) and Bland-Altman plots. Median Vsegmented and V1-V6 were 75.9, 124.9, 111.6, 94.0, 94.4, 61.7 and 80.3 cm(3), respectively. There was strong intra- and interobserver agreement for Vsegmented. Agreement with Vsegmented was highest for V6 (scalene ellipsoid, x ≠ y ≠ z), with CCC of 0.96 [95 % CI 0.95-0.97]. Mean relative difference was smallest for V6 (0.6 %), while it was -19.1 % for V5, +14.5 % for V4, +17.9 % for V3, +32.6 % for V2 and +47 % for V1. Ellipsoidal approximations of volume using three measured axes may be used to closely estimate Vsegmented when semiautomated techniques are unavailable. Estimation of tumour volume in primary GIST using mathematical formulae is feasible. Gastric GISTs are rarely spherical. Segmented volumes are highly concordant with three axis-based scalene ellipsoid volumes. Ellipsoid volume can be used as an alternative for automated tumour volumetry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Kortes, N.; Zelzer, S.
2011-02-15
The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs.more » To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.« less
Four-zone varifocus mirrors with adaptive control of primary and higher-order spherical aberration
Lukes, Sarah J.; Downey, Ryan D.; Kreitinger, Seth T.; Dickensheets, David L.
2017-01-01
Electrostatically actuated deformable mirrors with four concentric annular electrodes can exert independent control over defocus as well as primary, secondary, and tertiary spherical aberration. In this paper we use both numerical modeling and physical measurements to characterize recently developed deformable mirrors with respect to the amount of spherical aberration each can impart, and the dependence of that aberration control on the amount of defocus the mirror is providing. We find that a four-zone, 4 mm diameter mirror can generate surface shapes with arbitrary primary, secondary, and tertiary spherical aberration over ranges of ±0.4, ±0.2, and ±0.15 μm, respectively, referred to a non-normalized Zernike polynomial basis. We demonstrate the utility of this mirror for aberration-compensated focusing of a high NA optical system. PMID:27409212
Analysis of Activity Patterns and Performance in Polio Survivors
2006-10-01
variable were inspected for asymmetry and long-tailedness and normality. When appropriate, transformations (e.g. log function) were made. Data were...thighs and a combined pelvis -HAT segment was used for our analyses. The ankles were modeled as universal joints, the knees as revolutes, and the...segment, lumped pelvis + HAT, universal ankle, revolute knee, spherical hip; pin at CP entire stance Stance sagittal knee and frontal hip
Nogami, Yoshie; Ishizu, Tomoko; Atsumi, Akiko; Yamamoto, Masayoshi; Kawamura, Ryo; Seo, Yoshihiro; Aonuma, Kazutaka
2013-03-01
Recently developed vector flow mapping (VFM) enables evaluation of local flow dynamics without angle dependency. This study used VFM to evaluate quantitatively the index of intraventricular haemodynamic kinetic energy in patients with left ventricular (LV) diastolic dysfunction and to compare those with normal subjects. We studied 25 patients with estimated high left atrial (LA) pressure (pseudonormal: PN group) and 36 normal subjects (control group). Left ventricle was divided into basal, mid, and apical segments. Intraventricular haemodynamic energy was evaluated in the dimension of speed, and it was defined as the kinetic energy index. We calculated this index and created time-energy index curves. The time interval from electrocardiogram (ECG) R wave to peak index was measured, and time differences of the peak index between basal and other segments were defined as ΔT-mid and ΔT-apex. In both groups, early diastolic peak kinetic energy index in mid and apical segments was significantly lower than that in the basal segment. Time to peak index did not differ in apex, mid, and basal segments in the control group but was significantly longer in the apex than that in the basal segment in the PN group. ΔT-mid and ΔT-apex were significantly larger in the PN group than the control group. Multiple regression analysis showed sphericity index, E/E' to be significant independent variables determining ΔT apex. Retarded apical kinetic energy fluid dynamics were detected using VFM and were closely associated with LV spherical remodelling in patients with high LA pressure.
Intensity compensation for on-line detection of defects on fruit
NASA Astrophysics Data System (ADS)
Wen, Zhiqing; Tao, Yang
1997-10-01
A machine-vision sorting system was developed that utilizes the difference in light reflectance of fruit surfaces to distinguish the defective and good apples. To accommodate to the spherical reflectance characteristics of fruit with curved surface like apple, a spherical transform algorithm was developed that converts the original image to a non-radiant image without losing defective segments on the fruit. To prevent high-quality dark-colored fruit form being classified into the defective class and increase the defect detection rate for light-colored fruit, an intensity compensation method using maximum propagation was used. Experimental results demonstrated the effectiveness of the method based on maximum propagation and spherical transform for on-line detection of defects on apples.
Spherical torus fusion reactor
Peng, Yueng-Kay M.
1989-04-04
A fusion reactor is provided having a near spherical-shaped plasma with a modest central opening through which straight segments of toroidal field coils extend that carry electrical current for generating a toroidal magnet plasma confinement fields. By retaining only the indispensable components inboard of the plasma torus, principally the cooled toroidal field conductors and in some cases a vacuum containment vessel wall, the fusion reactor features an exceptionally small aspect ratio (typically about 1.5), a naturally elongated plasma cross section without extensive field shaping, requires low strength magnetic containment fields, small size and high beta. These features combine to produce a spherical torus plasma in a unique physics regime which permits compact fusion at low field and modest cost.
Spherical torus fusion reactor
Peng, Yueng-Kay M.
1989-01-01
A fusion reactor is provided having a near spherical-shaped plasma with a modest central opening through which straight segments of toroidal field coils extend that carry electrical current for generating a toroidal magnet plasma confinement fields. By retaining only the indispensable components inboard of the plasma torus, principally the cooled toroidal field conductors and in some cases a vacuum containment vessel wall, the fusion reactor features an exceptionally small aspect ratio (typically about 1.5), a naturally elongated plasma cross section without extensive field shaping, requires low strength magnetic containment fields, small size and high beta. These features combine to produce a spherical torus plasma in a unique physics regime which permits compact fusion at low field and modest cost.
NASA Technical Reports Server (NTRS)
Semkova, J.; Koleva, R.; Todorova, G.; Kanchev, N.; Petrov, V.; Shurshakov, V.; Tchhernykh, I.; Kireeva, S.
2004-01-01
Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
López-Miguel, Alberto; Martínez-Almeida, Loreto; González-García, María J; Coco-Martín, María B; Sobrado-Calvo, Paloma; Maldonado, Miguel J
2013-02-01
To assess the intrasession and intersession precision of ocular, corneal, and internal higher-order aberrations (HOAs) measured using an integrated topographer and Hartmann-Shack wavefront sensor (Topcon KR-1W) in refractive surgery candidates. IOBA-Eye Institute, Valladolid, Spain. Evaluation of diagnostic technology. To analyze intrasession repeatability, 1 experienced examiner measured eyes 9 times successively. To study intersession reproducibility, the same clinician obtained measurements from another set of eyes in 2 consecutive sessions 1 week apart. Ocular, corneal, and internal HOAs were obtained. Coma and spherical aberrations, 3rd- and 4th-order aberrations, and total HOAs were calculated for a 6.0 mm pupil diameter. For intrasession repeatability (75 eyes), excellent intraclass correlation coefficients (ICCs) were obtained (ICC >0.87), except for internal primary coma (ICC = 0.75) and 3rd-order (ICC = 0.72) HOAs. Repeatability precision (1.96 × S(w)) values ranged from 0.03 μm (corneal primary spherical) to 0.08 μm (ocular primary coma). For intersession reproducibility (50 eyes), ICCs were good (>0.8) for ocular primary spherical, 3rd-order, and total higher-order aberrations; reproducibility precision values ranged from 0.06 μm (corneal primary spherical) to 0.21 μm (internal 3rd order), with internal HOAs having the lowest precision (≥0.12 μm). No systematic bias was found between examinations on different days. The intrasession repeatability was high; therefore, the device's ability to measure HOAs in a reliable way was excellent. Under intersession reproducibility conditions, dependable corneal primary spherical aberrations were provided. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Puzzling Little Martian Spheres That Dont Taste Like Blueberries
2012-09-14
Small spherical objects fill the field in this mosaic combining four images from the Microscopic Imager on NASA Mars Exploration Rover Opportunity at an outcrop called Kirkwood in the Cape York segment of the western rim of Endeavour Crater.
Analysis and design of segment control system in segmented primary mirror
NASA Astrophysics Data System (ADS)
Yu, Wenhao; Li, Bin; Chen, Mo; Xian, Hao
2017-10-01
Segmented primary mirror will be adopted widely in giant telescopes in future, such as TMT, E-ELT and GMT. High-performance control technology of the segmented primary mirror is one of the difficult technologies for telescopes using segmented primary mirror. The control of each segment is the basis of control system in segmented mirror. Correcting the tilt and tip of single segment is the main work of this paper which is divided into two parts. Firstly, harmonic response done in finite element model of single segment matches the Bode diagram of a two-order system whose natural frequency is 45 hertz and damping ratio is 0.005. Secondly, a control system model is established, and speed feedback is introduced in control loop to suppress resonance point gain and increase the open-loop bandwidth, up to 30Hz or even higher. Corresponding controller is designed based on the control system model described above.
NASA Astrophysics Data System (ADS)
Lignell, David O.; Lansinger, Victoria B.; Medina, Juan; Klein, Marten; Kerstein, Alan R.; Schmidt, Heiko; Fistler, Marco; Oevermann, Michael
2018-06-01
The one-dimensional turbulence (ODT) model resolves a full range of time and length scales and is computationally efficient. ODT has been applied to a wide range of complex multi-scale flows, such as turbulent combustion. Previous ODT comparisons to experimental data have focused mainly on planar flows. Applications to cylindrical flows, such as round jets, have been based on rough analogies, e.g., by exploiting the fortuitous consistency of the similarity scalings of temporally developing planar jets and spatially developing round jets. To obtain a more systematic treatment, a new formulation of the ODT model in cylindrical and spherical coordinates is presented here. The model is written in terms of a geometric factor so that planar, cylindrical, and spherical configurations are represented in the same way. Temporal and spatial versions of the model are presented. A Lagrangian finite-volume implementation is used with a dynamically adaptive mesh. The adaptive mesh facilitates the implementation of cylindrical and spherical versions of the triplet map, which is used to model turbulent advection (eddy events) in the one-dimensional flow coordinate. In cylindrical and spherical coordinates, geometric stretching of the three triplet map images occurs due to the radial dependence of volume, with the stretching being strongest near the centerline. Two triplet map variants, TMA and TMB, are presented. In TMA, the three map images have the same volume, but different radial segment lengths. In TMB, the three map images have the same radial segment lengths, but different segment volumes. Cylindrical results are presented for temporal pipe flow, a spatial nonreacting jet, and a spatial nonreacting jet flame. These results compare very well to direct numerical simulation for the pipe flow, and to experimental data for the jets. The nonreacting jet treatment overpredicts velocity fluctuations near the centerline, due to the geometric stretching of the triplet maps and its effect on the eddy event rate distribution. TMB performs better than TMA. A hybrid planar-TMB (PTMB) approach is also presented, which further improves the results. TMA, TMB, and PTMB are nearly identical in the pipe flow where the key dynamics occur near the wall away from the centerline. The jet flame illustrates effects of variable density and viscosity, including dilatational effects.
Spherical demons: fast diffeomorphic landmark-free surface registration.
Yeo, B T Thomas; Sabuncu, Mert R; Vercauteren, Tom; Ayache, Nicholas; Fischl, Bruce; Golland, Polina
2010-03-01
We present the Spherical Demons algorithm for registering two spherical images. By exploiting spherical vector spline interpolation theory, we show that a large class of regularizors for the modified Demons objective function can be efficiently approximated on the sphere using iterative smoothing. Based on one parameter subgroups of diffeomorphisms, the resulting registration is diffeomorphic and fast. The Spherical Demons algorithm can also be modified to register a given spherical image to a probabilistic atlas. We demonstrate two variants of the algorithm corresponding to warping the atlas or warping the subject. Registration of a cortical surface mesh to an atlas mesh, both with more than 160 k nodes requires less than 5 min when warping the atlas and less than 3 min when warping the subject on a Xeon 3.2 GHz single processor machine. This is comparable to the fastest nondiffeomorphic landmark-free surface registration algorithms. Furthermore, the accuracy of our method compares favorably to the popular FreeSurfer registration algorithm. We validate the technique in two different applications that use registration to transfer segmentation labels onto a new image 1) parcellation of in vivo cortical surfaces and 2) Brodmann area localization in ex vivo cortical surfaces.
Spherical Demons: Fast Diffeomorphic Landmark-Free Surface Registration
Yeo, B.T. Thomas; Sabuncu, Mert R.; Vercauteren, Tom; Ayache, Nicholas; Fischl, Bruce; Golland, Polina
2010-01-01
We present the Spherical Demons algorithm for registering two spherical images. By exploiting spherical vector spline interpolation theory, we show that a large class of regularizors for the modified Demons objective function can be efficiently approximated on the sphere using iterative smoothing. Based on one parameter subgroups of diffeomorphisms, the resulting registration is diffeomorphic and fast. The Spherical Demons algorithm can also be modified to register a given spherical image to a probabilistic atlas. We demonstrate two variants of the algorithm corresponding to warping the atlas or warping the subject. Registration of a cortical surface mesh to an atlas mesh, both with more than 160k nodes requires less than 5 minutes when warping the atlas and less than 3 minutes when warping the subject on a Xeon 3.2GHz single processor machine. This is comparable to the fastest non-diffeomorphic landmark-free surface registration algorithms. Furthermore, the accuracy of our method compares favorably to the popular FreeSurfer registration algorithm. We validate the technique in two different applications that use registration to transfer segmentation labels onto a new image: (1) parcellation of in-vivo cortical surfaces and (2) Brodmann area localization in ex-vivo cortical surfaces. PMID:19709963
Welter, S; Stöcker, C; Dicken, V; Kühl, H; Krass, S; Stamatis, G
2012-03-01
Segmental resection in stage I non-small cell lung cancer (NSCLC) has been well described and is considered to have similar survival rates as lobectomy but with increased rates of local tumour recurrence due to inadequate parenchymal margins. In consequence, today segmentectomy is only performed when the tumour is smaller than 2 cm. Three-dimensional reconstructions from 11 thin-slice CT scans of bronchopulmonary segments were generated, and virtual spherical tumours were placed over the segments, respecting all segmental borders. As a next step, virtual parenchymal safety margins of 2 cm and 3 cm were subtracted and the size of the remaining tumour calculated. The maximum tumour diameters with a 30-mm parenchymal safety margin ranged from 26.1 mm in right-sided segments 7 + 8 to 59.8 mm in the left apical segments 1-3. Using a three-dimensional reconstruction of lung CT scans, we demonstrated that segmentectomy or resection of segmental groups should be feasible with adequate margins, even for larger tumours in selected cases. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Weiyu, Cao; Tashiro, Kohji; Hanesaka, Makoto; Takeda, Shinichi; Masunaga, Hiroyasu; Sasaki, Sono; Takata, Masaki
2009-02-26
The phase transition behaviors of low-molecular-weight polyethylene-poly(ethylene oxide) (PE-b-PEO) diblock copolymers with the monomeric units of PE/PEO = 17/40 and 39/86 have been successfully investigated through the temperature-dependent measurements of wide-angle X-ray diffraction (WAXD), small-angle X-ray scattering (SAXS), infrared and Raman spectra, as well as thermal analysis. These diblock copolymers had been believed to show only order-to-disorder transition of lamellar morphology in a wide temperature region, but it has been found here for the first time that this copolymer clearly exhibits the three stages of transitions among lamella, gyroid, cylinder, and spherical phases in the heating and cooling processes. The WAXD and IR/Raman spectral measurements allowed us to relate these morphological changes to the microscopic changes in the aggregation states of PEO and PE segments. In the low-temperature region the PEO segments form the monoclinic crystal of (7/2) helical chain conformation and the PE segments of planar-zigzag form take the orthorhombic crystalline phase. These crystalline lamellae of PEO and PE segments are alternately stacked with the long period of 165 Angstroms. In a higher temperature region, where the PEO crystalline parts are on the way of melting but the PE parts are still in the orthorhombic phase, the gyroid morphology is detected in the SAXS data. By heating further, the gyroid morphology changes to the hexagonally packed cylindrical morphology, where the orthorhombic phase of PE segments is gradually disordered because of thermally activated molecular motion and finally transforms to the pseudohexagonal or rotator phase. Once the PE segments are perfectly melted, the higher-order structure changes from the cylinder to the spherical morphology. These morphological transitions might relate to the thermally activated motions of two short chain segments of the diblock copolymer, although the details of the transition mechanism are unclear at the present stage.
Design and analysis of aspherical multilayer imaging X-ray microscope
NASA Technical Reports Server (NTRS)
Shealy, David L.; Jiang, WU; Hoover, Richard B.
1991-01-01
Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.
Mining volume measurement system
NASA Technical Reports Server (NTRS)
Heyman, Joseph Saul (Inventor)
1988-01-01
In a shaft with a curved or straight primary segment and smaller off-shooting segments, at least one standing wave is generated in the primary segment. The shaft has either an open end or a closed end and approximates a cylindrical waveguide. A frequency of a standing wave that represents the fundamental mode characteristic of the primary segment can be measured. Alternatively, a frequency differential between two successive harmonic modes that are characteristic of the primary segment can be measured. In either event, the measured frequency or frequency differential is characteristic of the length and thus the volume of the shaft based on length times the bore area.
New Convex and Spherical Structures of Bare Boron Clusters
NASA Astrophysics Data System (ADS)
Boustani, Ihsan
1997-10-01
New stable structures of bare boron clusters can easily be obtained and constructed with the help of an "Aufbau Principle" suggested by a systematicab initioHF-SCF and direct CI study. It is concluded that boron cluster formation can be established by elemental units of pentagonal and hexagonal pyramids. New convex and small spherical clusters different from the classical known forms of boron crystal structures are obtained by a combination of both basic units. Convex structures simulate boron surfaces which can be considered as segments of open or closed spheres. Both convex clusters B16and B46have energies close to those of their conjugate quasi-planar clusters, which are relatively stable and can be considered to act as a calibration mark. The closed spherical clusters B12, B22, B32, and B42are less stable than the corresponding conjugated quasi-planar structures. As a consequence, highly stable spherical boron clusters can systematically be predicted when their conjugate quasi-planar clusters are determined and energies are compared.
Optical Design of Segmented Hexagon Array Solar Mirror
NASA Technical Reports Server (NTRS)
Huegele, Vince
2000-01-01
A segmented array of mirrors was designed for a solar concentrator test stand at MSFC for firing solar thermal propulsion engines. The 144 mirrors each have a spherical surface to approximate a parabolic concentrator when combined into the entire 18-foot diameter array. The mirror segments are aluminum hexagons that had the surface diamond turned and quartz coated. The array focuses sunlight reflected from a heliostat to a 4 inch diameter spot containing 10 kw of power at the 15-foot focal point. The derivation of the surface figure for the respective mirror elements is shown. The alignment process of the array is discussed and test results of the system's performance is given.
Association between Refractive Errors and Ocular Biometry in Iranian Adults
Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar
2015-01-01
Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304
[Effect of the ISS Russian segment configuration on the service module radiation environment].
Mitrikas, V G
2011-01-01
Mathematical modeling of variations in the Service module radiation environment as a function of ISS Russian segment configuration was carried out using models of the RS modules and a spherical humanoid phantom. ISS reconfiguration impacted significantly only the phantom brought into the transfer compartment (ExT). The Radiation Safety Service prohibition for cosmonauts to stay in this compartment during solar flare events remains valid. In all other instances, error of dose estimation is higher as compared to dose value estimation with consideration for ISS RS reconfiguration.
Process for manufacture of inertial confinement fusion targets and resulting product
Masnari, Nino A.; Rensel, Walter B.; Robinson, Merrill G.; Solomon, David E.; Wise, Kensall D.; Wuttke, Gilbert H.
1982-01-01
An ICF target comprising a spherical pellet of fusion fuel surrounded by a concentric shell; and a process for manufacturing the same which includes the steps of forming hemispheric shells of a silicon or other substrate material, adhering the shell segments to each other with a fuel pellet contained concentrically therein, then separating the individual targets from the parent substrate. Formation of hemispheric cavities by deposition or coating of a mold substrate is also described. Coatings or membranes may also be applied to the interior of the hemispheric segments prior to joining.
Black strings, low viscosity fluids, and violation of cosmic censorship.
Lehner, Luis; Pretorius, Frans
2010-09-03
We describe the behavior of 5-dimensional black strings, subject to the Gregory-Laflamme instability. Beyond the linear level, the evolving strings exhibit a rich dynamics, where at intermediate stages the horizon can be described as a sequence of 3-dimensional spherical black holes joined by black string segments. These segments are themselves subject to a Gregory-Laflamme instability, resulting in a self-similar cascade, where ever-smaller satellite black holes form connected by ever-thinner string segments. This behavior is akin to satellite formation in low-viscosity fluid streams subject to the Rayleigh-Plateau instability. The simulation results imply that the string segments will reach zero radius in finite asymptotic time, whence the classical space-time terminates in a naked singularity. Since no fine-tuning is required to excite the instability, this constitutes a generic violation of cosmic censorship.
Wang, Decai; Liu, Bin; Huang, Shengsong; Huang, Wenyong; He, Mingguang
2014-09-01
A cross-sectional study was conducted to explore the relationship between refractive error and ocular biometrics in children from the Guangzhou twin eye study. Twin participants aged 7-15 years were selected from Guangzhou Twin Eye Study. Ocular examinations included visual acuity measurement, ocular motility evaluation, autorefraction under cycloplegia, and anterior segment, media, and fundus examination. Axial length (AL), anterior chamber depth (ACD), and corneal curvature radius were measured using partial coherence laser interferometry. A multivariate linear regression model was used for statistical analysis. Twin children from Guangzhou city showed a decreased spherical equivalent with age, whereas both AL and ACD were increased and corneal curvature radius remained unchanged. When adjusted by age and gender, the data from 77% of twins presenting with spherical equivalent changes indicated that these were caused by predictable variables (R2 = 0.77, P < 0.001). Primary factors affecting children's refraction included axial length (β = -0.97,P < 0.001), ACD (β = 0.33, P < 0.001), and curvature radius (β = 2.10, P < 0.001). Girls had a higher tendency for myopic status than did boys (β = -0.26, P < 0.001). Age exerted no effect upon the changes in refraction (β = -0.01, P = 0.25). Refraction is correlated with ocular biometrics. Refractive status is largely determined by axial length as the major factor.
Software for Alignment of Segments of a Telescope Mirror
NASA Technical Reports Server (NTRS)
Hall, Drew P.; Howard, Richard T.; Ly, William C.; Rakoczy, John M.; Weir, John M.
2006-01-01
The Segment Alignment Maintenance System (SAMS) software is designed to maintain the overall focus and figure of the large segmented primary mirror of the Hobby-Eberly Telescope. This software reads measurements made by sensors attached to the segments of the primary mirror and from these measurements computes optimal control values to send to actuators that move the mirror segments.
NASA Astrophysics Data System (ADS)
Yu, Haitao; Sun, Hui; Shen, Jianqi; Tropea, Cameron
2018-03-01
The primary rainbow observed when light is scattered by a spherical drop has been exploited in the past to measure drop size and relative refractive index. However, if higher spatial resolution is required in denser drop ensembles/sprays, and to avoid then multiple drops simultaneously appearing in the measurement volume, a highly focused beam is desirable, inevitably with a Gaussian intensity profile. The present study examines the primary rainbow pattern resulting when a Gaussian beam is scattered by a spherical drop and estimates the attainable accuracy when extracting size and refractive index. The scattering is computed using generalized Lorenz-Mie theory (GLMT) and Debye series decomposition of the Gaussian beam scattering. The results of these simulations show that the measurement accuracy is dependent on both the beam waist radius and the position of the drop in the beam waist.
Primary versus secondary achalasia: New signs on barium esophagogram
Gupta, Pankaj; Debi, Uma; Sinha, Saroj Kant; Prasad, Kaushal Kishor
2015-01-01
Aim: To investigate new signs on barium swallow that can differentiate primary from secondary achalasia. Materials and Methods: Records of 30 patients with primary achalasia and 17 patients with secondary achalasia were reviewed. Clinical, endoscopic, and manometric data was recorded. Barium esophagograms were evaluated for peristalsis and morphology of distal esophageal segment (length, symmetry, nodularity, shouldering, filling defects, and “tram-track sign”). Results: Mean age at presentation was 39 years in primary achalasia and 49 years in secondary achalasia. The mean duration of symptoms was 3.5 years in primary achalasia and 3 months in secondary achalasia. False-negative endoscopic results were noted in the first instance in five patients. In the secondary achalasia group, five patients had distal esophageal segment morphology indistinguishable from that of primary achalasia. None of the patients with primary achalasia and 35% patients with secondary achalasia had a length of the distal segment approaching combined height of two vertebral bodies. None of the patients with secondary achalasia and 34% patients with primary achalasia had maximum caliber of esophagus approaching combined height of two vertebral bodies. Tertiary contractions were noted in 90% patients with primary achalasia and 24% patients with secondary achalasia. Tram-track sign was found in 55% patients with primary achalasia. Filling defects in the distal esophageal segment were noted in 94% patients with secondary achalasia. Conclusion: Length of distal esophageal segment, tertiary contractions, tram-track sign, and filling defects in distal esophageal segment are useful esophagographic features distinguishing primary from secondary achalasia. PMID:26288525
The elastic field induced by a hemispherical inclusion in the half-space
NASA Astrophysics Data System (ADS)
Wu, Linzhi
2003-06-01
The elastic field induced by a hekispherical inclusion with uniform eigenstrains in a semi-infinite elastic medium is solved by using the Green's function method and series expansion technique. The exact solutions are presented for the displacement and stress fields which can be expressed by complete elliptic integrals of the first, second, and third kinds and hypergeometric functions. The present method can be used to determine the corresponding elastic fields when the shape of the inclusion is a spherical crown or a spherical segment. Finally, numerical results are given for the displacement and stress fields along the axis of symmetry ( x 3-axis).
Engineering single-polymer micelle shape using nonuniform spontaneous surface curvature
NASA Astrophysics Data System (ADS)
Moths, Brian; Witten, T. A.
2018-03-01
Conventional micelles, composed of simple amphiphiles, exhibit only a few standard morphologies, each characterized by its mean surface curvature set by the amphiphiles. Here we demonstrate a rational design scheme to construct micelles of more general shape from polymeric amphiphiles. We replace the many amphiphiles of a conventional micelle by a single flexible, linear, block copolymer chain containing two incompatible species arranged in multiple alternating segments. With suitable segment lengths, the chain exhibits a condensed spherical configuration in solution, similar to conventional micelles. Our design scheme posits that further shapes are attained by altering the segment lengths. As a first study of the power of this scheme, we demonstrate the capacity to produce long-lived micelles of horseshoe form using conventional bead-spring simulations in two dimensions. Modest changes in the segment lengths produce smooth changes in the micelle's shape and stability.
Gerhardt, S P; Fredrickson, E; Guttadora, L; Kaita, R; Kugel, H; Menard, J; Takahashi, H
2011-10-01
This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The measurements are based on three techniques: (1) measurement of the toroidal field created by the poloidal halo current, either with segmented Rogowski coils or discrete toroidal field sensors, (2) the direct measurement of halo currents into specially instrument tiles, and (3) small Rogowski coils placed on the mechanical supports of in-vessel components. For the segmented Rogowski coils and discrete toroidal field detectors, it is shown that the toroidal peaking factor inferred from the data is significantly less than the peaking factor of the underlying halo current distribution, and a simple model is developed to relate the two. For the array of discrete toroidal field detectors and small Rogowski sensors, the compensation steps that are used to isolate the halo current signal are described. The electrical and mechanical design of compact under-tile resistive shunts and mini-Rogowski coils is described. Example data from the various systems are shown.
Real-Time Motion Tracking for Indoor Moving Sphere Objects with a LiDAR Sensor.
Huang, Lvwen; Chen, Siyuan; Zhang, Jianfeng; Cheng, Bang; Liu, Mingqing
2017-08-23
Object tracking is a crucial research subfield in computer vision and it has wide applications in navigation, robotics and military applications and so on. In this paper, the real-time visualization of 3D point clouds data based on the VLP-16 3D Light Detection and Ranging (LiDAR) sensor is achieved, and on the basis of preprocessing, fast ground segmentation, Euclidean clustering segmentation for outliers, View Feature Histogram (VFH) feature extraction, establishing object models and searching matching a moving spherical target, the Kalman filter and adaptive particle filter are used to estimate in real-time the position of a moving spherical target. The experimental results show that the Kalman filter has the advantages of high efficiency while adaptive particle filter has the advantages of high robustness and high precision when tested and validated on three kinds of scenes under the condition of target partial occlusion and interference, different moving speed and different trajectories. The research can be applied in the natural environment of fruit identification and tracking, robot navigation and control and other fields.
Real-Time Motion Tracking for Indoor Moving Sphere Objects with a LiDAR Sensor
Chen, Siyuan; Zhang, Jianfeng; Cheng, Bang; Liu, Mingqing
2017-01-01
Object tracking is a crucial research subfield in computer vision and it has wide applications in navigation, robotics and military applications and so on. In this paper, the real-time visualization of 3D point clouds data based on the VLP-16 3D Light Detection and Ranging (LiDAR) sensor is achieved, and on the basis of preprocessing, fast ground segmentation, Euclidean clustering segmentation for outliers, View Feature Histogram (VFH) feature extraction, establishing object models and searching matching a moving spherical target, the Kalman filter and adaptive particle filter are used to estimate in real-time the position of a moving spherical target. The experimental results show that the Kalman filter has the advantages of high efficiency while adaptive particle filter has the advantages of high robustness and high precision when tested and validated on three kinds of scenes under the condition of target partial occlusion and interference, different moving speed and different trajectories. The research can be applied in the natural environment of fruit identification and tracking, robot navigation and control and other fields. PMID:28832520
Gerhardt, S. P.; Fredrickson, E.; Guttadora, L.; ...
2011-10-06
This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments. The measurements are based on three techniques: (i) measurement of the toroidal field created by the poloidal halo current, either with segmented Rogowski coils or discrete toroidal field sensors, (ii) the direct measurement of halo currents into specially instrument tiles, and (iii) small Rogowski coils placed on the mechanical supports of in-vessel components. For the segmented Rogowski coils and discrete toroidal field detectors, it is shown that the toroidal peaking factor inferred from the data is significantly less than the peakingmore » factor of the underlying halo current distribution, and a simple model is developed to relate the two. For the array of discrete toroidal field detectors and small Rogowski sensors, the compensation steps that are used to isolate the halo current signal are described. The electrical and mechanical design of compact under-tile resistive shunts and mini-Rogowski coils is described. Example data from the various systems is shown.« less
Van't Hof, Arnoud; Giannini, Francesco; Ten Berg, Jurrien; Tolsma, Rudolf; Clemmensen, Peter; Bernstein, Debra; Coste, Pierre; Goldstein, Patrick; Zeymer, Uwe; Hamm, Christian; Deliargyris, Efthymios; Steg, Philippe G
2017-08-01
Myocardial reperfusion after primary percutaneous coronary intervention (PCI) can be assessed by the extent of post-procedural ST-segment resolution. The European Ambulance Acute Coronary Syndrome Angiography (EUROMAX) trial compared pre-hospital bivalirudin and pre-hospital heparin or enoxaparin with or without GPIIb/IIIa inhibitors (GPIs) in primary PCI. This nested substudy was performed in centres routinely using pre-hospital GPI in order to compare the impact of randomized treatments on ST-resolution after primary PCI. Residual cumulative ST-segment deviation on the single one hour post-procedure electrocardiogram (ECG) was assessed by an independent core laboratory and was the primary endpoint. It was calculated that 762 evaluable patients were needed to show non-inferiority (85% power, alpha 2.5%) between randomized treatments. A total of 871 participated with electrocardiographic data available in 824 patients (95%). Residual ST-segment deviation one hour after PCI was 3.8±4.9 mm versus 3.9±5.2 mm for bivalirudin and heparin+GPI, respectively ( p=0.0019 for non-inferiority). Overall, there were no differences between randomized treatments in any measures of ST-segment resolution either before or after the index procedure. Pre-hospital treatment with bivalirudin is non-inferior to pre-hospital heparin + GPI with regard to residual ST-segment deviation or ST-segment resolution, reflecting comparable myocardial reperfusion with the two strategies.
Fast Appearance Modeling for Automatic Primary Video Object Segmentation.
Yang, Jiong; Price, Brian; Shen, Xiaohui; Lin, Zhe; Yuan, Junsong
2016-02-01
Automatic segmentation of the primary object in a video clip is a challenging problem as there is no prior knowledge of the primary object. Most existing techniques thus adapt an iterative approach for foreground and background appearance modeling, i.e., fix the appearance model while optimizing the segmentation and fix the segmentation while optimizing the appearance model. However, these approaches may rely on good initialization and can be easily trapped in local optimal. In addition, they are usually time consuming for analyzing videos. To address these limitations, we propose a novel and efficient appearance modeling technique for automatic primary video object segmentation in the Markov random field (MRF) framework. It embeds the appearance constraint as auxiliary nodes and edges in the MRF structure, and can optimize both the segmentation and appearance model parameters simultaneously in one graph cut. The extensive experimental evaluations validate the superiority of the proposed approach over the state-of-the-art methods, in both efficiency and effectiveness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dubey, P., E-mail: purushd@barc.gov.in; Sharma, V. K.; Mitra, S.
Synthetic hydroxyapatite (HAp) is an important material in biomedical engineering due to its excellent biocompatibility and bioactivity. Here we report dynamics of cetyltrimethylammonium bromide (CTAB) in HAp composite, prepared by co-precipitation method, as studied by quasielastic neutron scattering (QENS) technique. It is found that the observed dynamics involved two time scales associated with fast torsional motion and segmental motion of the CTAB monomers. In addition to segmental motion of the hydrogen atoms, few undergo torsional motion as well. Torsional dynamics was described by a 2-fold jump diffusion model. The segmental dynamics of CTAB has been described assumimg the hydrogen atomsmore » undergoing diffusion inside a sphere of confined volume. While the diffusivity is found to increase with temperature, the spherical volumes within which the hydrogen atoms are undergoing diffusion remain almost unchanged.« less
NASA Technical Reports Server (NTRS)
Valinia, Azita; Moe, Rud; Seery, Bernard D.; Mankins, John C.
2013-01-01
We present a concept for an ISS-based optical system assembly demonstration designed to advance technologies related to future large in-space optical facilities deployment, including space solar power collectors and large-aperture astronomy telescopes. The large solar power collector problem is not unlike the large astronomical telescope problem, but at least conceptually it should be easier in principle, given the tolerances involved. We strive in this application to leverage heavily the work done on the NASA Optical Testbed Integration on ISS Experiment (OpTIIX) effort to erect a 1.5 m imaging telescope on the International Space Station (ISS). Specifically, we examine a robotic assembly sequence for constructing a large (meter diameter) slightly aspheric or spherical primary reflector, comprised of hexagonal mirror segments affixed to a lightweight rigidizing backplane structure. This approach, together with a structured robot assembler, will be shown to be scalable to the area and areal densities required for large-scale solar concentrator arrays.
Primary Segmental Volvulus Mimicking Ileal Atresia
Rao, Sadashiva; B Shetty, Kishan
2013-01-01
Neonatal intestinal volvulus in the absence of malrotation is a rare occurrence and rarer still is the intestinal volvulus in absence of any other predisposing factors. Primary segmental volvulus in neonates is very rare entity, which can have catastrophic outcome if not intervened at appropriate time. We report two such cases, which were preoperatively diagnosed as ileal atresia and intraoperatively revealed to be primary segmental volvulus of the ileum. PMID:26023426
Bradley, Arthur; Xu, Renfeng; Thibos, Larry; Marin, Gildas; Hernandez, Martha
2014-01-01
Purpose To test competing hypotheses (Stiles Crawford pupil apodising or superior imaging of high spatial frequencies by the central pupil) for the pupil size independence of subjective refractions in the presence of primary spherical aberration. Methods Subjective refractions were obtained with a variety of test stimuli (high contrast letters, urban cityscape, high and low spatial frequency gratings) while modulating pupil diameter, levels of primary spherical aberration and pupil apodisation. Subjective refractions were also obtained with low-pass and high-pass stimuli and using “darker” and “sharper” subjective criteria. Results Subjective refractions for stimuli containing high spatial frequencies focus a near paraxial region of the pupil and are affected only slightly by level of Seidel spherical aberration, degree of pupil apodisation and pupil diameter, and generally focused a radius of about 1 to 1.5 mm from the pupil centre. Low spatial frequency refractions focus a marginal region of the pupil, and are significantly affected by level of spherical aberration, amount of pupil apodisation, and pupil size. Clinical refractions that employ the “darker” or “sharper” subjective criteria bias the patient to use lower or higher spatial frequencies respectively. Conclusions In the presence of significant levels of spherical aberration, the pupil size independence of subjective refractions occurs with or without Stiles Crawford apodisation for refractions that optimise high spatial frequency content in the image. If low spatial frequencies are optimised by a subjective refraction, spherical refractive error varies with spherical aberration, pupil size, and level of apodisation. As light levels drop from photopic to scotopic, therefore, we expect a shift from pupil size independent to pupil size dependent subjective refractions. Emphasising a “sharper” criterion during subjective refractions will improve image quality for high spatial frequencies and generate pupil size independent refractions. PMID:24397356
Spherical Model of Interests in Croatia
ERIC Educational Resources Information Center
Sverko, Iva
2008-01-01
In order to analyze the validity of spherical model of interests in Croatia, three Croatian samples of primary school students (N = 437), secondary school students (N = 540) and university students (N = 630) were administered a translated version of the Personal Globe Inventory (PGI, [Tracey, T.J.G. (2002). Personal Globe Inventory: Measurement of…
SIRTF primary mirror design, analysis, and testing
NASA Technical Reports Server (NTRS)
Sarver, George L., III; Maa, Scott; Chang, LI
1990-01-01
The primary mirror assembly (PMA) requirements and concepts for the Space Infrared Telescope Facility (SIRTF) program are discussed. The PMA studies at NASA/ARC resulted in the design of two engineering test articles, the development of a mirror mount cryogenic static load testing system, and the procurement and partial testing of a full scale spherical mirror mounting system. Preliminary analysis and testing of the single arch mirror with conical mount design and the structured mirror with the spherical mount design indicate that the designs will meet all figure and environmental requirements of the SIRTF program.
In Ovo Electroporation for Targeting the Somitic Mesoderm
NASA Astrophysics Data System (ADS)
Ohata, Emi; Takahashi, Yoshiko
The somite is a transient structure present in early vertebrate embryos, giving rise to a variety of essential tissues including skeletal muscles, dermis, axial bones and blood vessels. The term “somite” refers to a tissue of spherical structure that forms by pinching off from the continuous tissue called presomitic mesoderm (PSM, also called segmental plate in avian embryos). The PSM is recognized as a pair of longitudinal stripes along the midline of the body. Thus, each somite forms at the anterior end of PSM, and this process recurs periodically in time and space, gener ating the segmented pattern of the body along the antero-posterior axis.
Chen, Tai-Been; Chen, Jyh-Cheng; Lu, Henry Horng-Shing
2012-01-01
Segmentation of positron emission tomography (PET) is typically achieved using the K-Means method or other approaches. In preclinical and clinical applications, the K-Means method needs a prior estimation of parameters such as the number of clusters and appropriate initialized values. This work segments microPET images using a hybrid method combining the Gaussian mixture model (GMM) with kernel density estimation. Segmentation is crucial to registration of disordered 2-deoxy-2-fluoro-D-glucose (FDG) accumulation locations with functional diagnosis and to estimate standardized uptake values (SUVs) of region of interests (ROIs) in PET images. Therefore, simulation studies are conducted to apply spherical targets to evaluate segmentation accuracy based on Tanimoto's definition of similarity. The proposed method generates a higher degree of similarity than the K-Means method. The PET images of a rat brain are used to compare the segmented shape and area of the cerebral cortex by the K-Means method and the proposed method by volume rendering. The proposed method provides clearer and more detailed activity structures of an FDG accumulation location in the cerebral cortex than those by the K-Means method.
The Contribution of Segmental and Suprasegmental Phonology to Reading Comprehension
ERIC Educational Resources Information Center
Veenendaal, Nathalie J.; Groen, Margriet A.; Verhoeven, Ludo
2016-01-01
The aim of the present study was to examine the relation between decoding and segmental and suprasegmental phonology, and their contribution to reading comprehension, in the upper primary grades. Following a longitudinal design, the performance of 99 Dutch primary school students on phonological awareness (segmental phonology) and text-reading…
NASA Technical Reports Server (NTRS)
Rakoczy, John; Whitaker, Ann F. (Technical Monitor)
2001-01-01
NASA's Marshall Space Flight Center, in collaboration with Blue Line Engineering of Colorado Springs, Colorado, is developing a Segment Alignment Maintenance System (SAMS) for McDonald Observatory's Hobby-Eberly Telescope (HET). The SAMS shall sense motions of the 91 primary mirror segments and send corrections to HET's primary mirror controller as the mirror segments misalign due to thermo-elastic deformations of the mirror support structure. The SAMS consists of inductive edge sensors supplemented by inclinometers for global radius of curvature sensing. All measurements are sent to the SAMS computer where mirror motion corrections are calculated. In October 2000, a prototype SAMS was installed on a seven-segment cluster of the HET. Subsequent testing has shown that the SAMS concept and architecture are a viable practical approach to maintaining HET's primary mirror figure, or the figure of any large segmented telescope. This paper gives a functional description of the SAMS sub-array components and presents test data to characterize the performance of the sub-array SAMS.
Segment Alignment Maintenance System for the Hobby-Eberly Telescope
NASA Technical Reports Server (NTRS)
Rakoczy, John; Burdine, Robert (Technical Monitor)
2001-01-01
NASA's Marshall Space Flight Center, in collaboration with Blue Line Engineering of Colorado Springs, Colorado, is developing a Segment Alignment Maintenance System (SAMS) for McDonald Observatory's Hobby-Eberly Telescope (HET). The SAMS shall sense motions of the 91 primary mirror segments and send corrections to HET's primary mirror controller as the mirror segments misalign due to thermo -elastic deformations of the mirror support structure. The SAMS consists of inductive edge sensors. All measurements are sent to the SAMS computer where mirror motion corrections are calculated. In October 2000, a prototype SAMS was installed on a seven-segment cluster of the HET. Subsequent testing has shown that the SAMS concept and architecture are a viable practical approach to maintaining HET's primary mirror figure, or the figure of any large segmented telescope. This paper gives a functional description of the SAMS sub-array components and presents test data to characterize the performance of the subarray SAMS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Javni, Ivan; Bilić, Olivera; Bilić, Nikola
2015-06-30
Isosorbide, a cyclic, rigid and renewable diol was used as a chain extender in two series of thermoplastic polyurethanes. Isosorbide was used in combination with butane diol or alone to examine the effects on polyurethane morphology. Two series of materials were prepared -one with dispersed hard domains in the matrix of polytetramethylene ether glycol soft segments of molecular weight 1400 (at 70% soft segment concentration-SSC) and the other with co-continuous soft and hard phases at 50% SSC. Morphology of materials was studied by optical and atomic force microscopy, as well as with ultra small angle x-ray scattering (USAXS). The radiusmore » of spherical hard domains, correlation lengths, mean separation distances and boundary layer thickness were measured as a function of isosorbide content.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindner, Benjamin; Petridis, Loukas; Langan, Paul
2014-10-01
Commonly one-dimensional (1D) (spherically averaged) powder diffraction diagrams are used to determine the degree of cellulose crystallinity in biomass samples. Here, it is shown using molecular modeling how disorder in cellulose fibrils can lead to considerable uncertainty in conclusions drawn concerning crystallinity based on 1D powder diffraction data alone. For example, cellulose microfibrils that contain both crystalline and noncrystalline segments can lead to powder diffraction diagrams lacking identifiable peaks, while microfibrils without any crystalline segments can lead to such peaks. Moreover, this leads to false positives, that is, assigning disordered cellulose as crystalline, and false negatives, that is, categorizing fibrilsmore » with crystalline segments as amorphous. Finally, the reliable determination of the fraction of crystallinity in any given biomass sample will require a more sophisticated approach combining detailed experiment and simulation.« less
Fore, Jeffrey D; Sowa, Scott P; Galat, David L; Annis, Gust M; Diamond, David D; Rewa, Charles
2014-03-01
Managers can improve conservation of lotic systems over large geographies if they have tools to assess total watershed conditions for individual stream segments and can identify segments where conservation practices are most likely to be successful (i.e., primary management capacity). The goal of this research was to develop a suite of threat indices to help agriculture resource management agencies select and prioritize watersheds across Missouri River basin in which to implement agriculture conservation practices. We quantified watershed percentages or densities of 17 threat metrics that represent major sources of ecological stress to stream communities into five threat indices: agriculture, urban, point-source pollution, infrastructure, and all non-agriculture threats. We identified stream segments where agriculture management agencies had primary management capacity. Agriculture watershed condition differed by ecoregion and considerable local variation was observed among stream segments in ecoregions of high agriculture threats. Stream segments with high non-agriculture threats were most concentrated near urban areas, but showed high local variability. 60 % of stream segments in the basin were classified as under U.S. Department of Agriculture's Natural Resources Conservation Service (NRCS) primary management capacity and most segments were in regions of high agricultural threats. NRCS primary management capacity was locally variable which highlights the importance of assessing total watershed condition for multiple threats. Our threat indices can be used by agriculture resource management agencies to prioritize conservation actions and investments based on: (a) relative severity of all threats, (b) relative severity of agricultural threats, and (c) and degree of primary management capacity.
Twelve automated thresholding methods for segmentation of PET images: a phantom study.
Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M
2012-06-21
Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical (18)F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.
Twelve automated thresholding methods for segmentation of PET images: a phantom study
NASA Astrophysics Data System (ADS)
Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M.
2012-06-01
Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.
Serotonin projection patterns to the cochlear nucleus.
Thompson, A M; Thompson, G C
2001-07-13
The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the dorsal cochlear nucleus, we concluded that the serotoninergic projection pattern to the cochlear nucleus is divergent and non-specific. Double-labeled fiber segments were also present, but sparse, in the superior olive, localized mainly in periolivary regions; this indicated that the divergence of dorsal and median raphe neurons that extends throughout regions of the cochlear nucleus also extended well beyond the cochlear nucleus to include at least the superior olivary complex as well.
Application of close-packed structures in dental resin composites.
Wang, Ruili; Habib, Eric; Zhu, X X
2017-03-01
The inorganic filler particles in dental resin composites serve to improve their mechanical properties and reduce polymerization shrinkage during their use. Efforts have been made in academia and industry to increase the filler particle content, but, few studies examine the theoretical basis for the maximum particle loading. This work evaluates the packing of spherical particles in a close-packed state for highly loaded composites. Calculations show that for low dispersity particles, the maximum amount of particles is 74.05vol%, regardless of the particle size. This can be further improved by using a mix of large and small particles or by the use of non-spherical particles. For representative spherical particles with a diameter of 1000nm, two types of secondary particles with respective sizes of 414nm (d I ) and 225nm (d II ) are selected. The results show that after embedding secondary particles I & II into primary spherical particles, the packing factor is increased to 81.19% for the close-packed structures, which shows an improvement of 9.64%, compared to the 74.05% obtained only with primary spherical particles. This packing factor is also higher than either structure with the embedded secondary particles I or II. Examples of these mixtures with different spherical particle sizes are shown as a theoretical estimation, serving as a guideline for the design and formulation of new dental resin composites with better properties and improved performance. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Doody, Thomas J.
1978-08-22
A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.
Ocular higher-order aberrations in a school children population.
Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K; Pallikaris, Ioannis G; Plainis, Sotiris
2015-01-01
The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. A sample of 557 children aged 10-15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7±0.5 years), group II (12.4±0.5 years) and group III (14.5±0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4lux). Wavefront analysis was achieved for a 5mm pupil. Statistical analysis was carried out for the right eye only. The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076μm) and horizontal (0.018μm) coma, oblique trefoil (-0.055μm) and spherical aberration (0.018μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007μm (SE 0.005) in group I to 0.011μm (SE 0.004) in group II and 0.030μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Ocular higher-order aberrations in a school children population
Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K.; Pallikaris, Ioannis G.; Plainis, Sotiris
2014-01-01
Purpose The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. Methods A sample of 557 children aged 10–15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7 ± 0.5 years), group II (12.4 ± 0.5 years) and group III (14.5 ± 0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4 lux). Wavefront analysis was achieved for a 5 mm pupil. Statistical analysis was carried out for the right eye only. Results The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076 μm) and horizontal (0.018 μm) coma, oblique trefoil (−0.055 μm) and spherical aberration (0.018 μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007 μm (SE 0.005) in group I to 0.011 μm (SE 0.004) in group II and 0.030 μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Conclusions Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. PMID:25288226
NASA Technical Reports Server (NTRS)
Seaver, E. C.; Shankland, M.
2000-01-01
We have investigated whether the development of segmental repeats is autonomous in the embryo of the leech Helobdella robusta. The segmental tissues of the germinal band arise from progeny of five stem cells called teloblasts. Asymmetric divisions of the teloblasts form chains of segment founder cells (called primary blast cells) that divide in a stereotypical manner to produce differentiated descendants. Using two distinct techniques, we have looked for potential interactions between neighboring blast cell clones along the anterior-posterior axis. In one technique, we prevented the birth of primary blast cells by injection of DNase I into the teloblast, thereby depriving the last blast cell produced before the ablation of its normal posterior neighbors. We also ablated single blast cells with a laser microbeam, which allowed us to assess potential signals acting on either more anterior or more posterior primary blast cell clones. Our results suggest that interactions along the anterior-posterior axis between neighboring primary blast cell clones are not required for development of normal segmental organization within the blast cell clone. We also examined the possibility that blast cells receive redundant signals from both anterior and posterior neighboring clones and that either is sufficient for normal development. Using double blast cell laser ablations to isolate a primary blast cell clone by removal of both its anterior and its posterior neighbor, we found that the isolated clone still develops normally. These results reveal that the fundamental segmental repeat in the leech embryo, the primary blast cell clone, can develop normally in the apparent absence of signals from adjacent repeats along the anterior-posterior axis.
A biomechanical study of artificial cervical discs using computer simulation.
Ahn, Hyung Soo; DiAngelo, Denis J
2008-04-15
A virtual simulation model of the subaxial cervical spine was used to study the biomechanical effects of various disc prosthesis designs. To study the biomechanics of different design features of cervical disc arthroplasty devices. Disc arthroplasty is an alternative approach to cervical fusion surgery for restoring and maintaining motion at a diseased spinal segment. Different types of cervical disc arthroplasty devices exist and vary based on their placement and degrees of motion offered. A virtual dynamic model of the subaxial cervical spine was used to study 3 different prosthetic disc designs (PDD): (1) PDD-I: The center of rotation of a spherical joint located at the mid C5-C6 disc, (2) PDD-II: The center of rotation of a spherical joint located 6.5 mm below the mid C5-C6 disc, and (3) PDD-III: The center of rotation of a spherical joint in a plane located at the C5-C6 disc level. A constrained spherical joint placed at the disc level (PDD-I) significantly increased facet loads during extension. Lowering the rotational axis of the spherical joint towards the subjacent body (PDD-II) caused a marginal increase in facet loading during flexion, extension, and lateral bending. Lastly, unconstraining the spherical joint to move freely in a plane (PDD-III) minimized facet load build up during all loading modes. The simulation model showed the impact simple design changes may have on cervical disc dynamics. The predicted facet loads calculated from computer model have to be validated in the experimental study.
Investigation of Primary Mirror Segment's Residual Errors for the Thirty Meter Telescope
NASA Technical Reports Server (NTRS)
Seo, Byoung-Joon; Nissly, Carl; Angeli, George; MacMynowski, Doug; Sigrist, Norbert; Troy, Mitchell; Williams, Eric
2009-01-01
The primary mirror segment aberrations after shape corrections with warping harness have been identified as the single largest error term in the Thirty Meter Telescope (TMT) image quality error budget. In order to better understand the likely errors and how they will impact the telescope performance we have performed detailed simulations. We first generated unwarped primary mirror segment surface shapes that met TMT specifications. Then we used the predicted warping harness influence functions and a Shack-Hartmann wavefront sensor model to determine estimates for the 492 corrected segment surfaces that make up the TMT primary mirror. Surface and control parameters, as well as the number of subapertures were varied to explore the parameter space. The corrected segment shapes were then passed to an optical TMT model built using the Jet Propulsion Laboratory (JPL) developed Modeling and Analysis for Controlled Optical Systems (MACOS) ray-trace simulator. The generated exit pupil wavefront error maps provided RMS wavefront error and image-plane characteristics like the Normalized Point Source Sensitivity (PSSN). The results have been used to optimize the segment shape correction and wavefront sensor designs as well as provide input to the TMT systems engineering error budgets.
Spherical loudspeaker array for local active control of sound.
Rafaely, Boaz
2009-05-01
Active control of sound has been employed to reduce noise levels around listeners' head using destructive interference from noise-canceling sound sources. Recently, spherical loudspeaker arrays have been studied as multiple-channel sound sources, capable of generating sound fields with high complexity. In this paper, the potential use of a spherical loudspeaker array for local active control of sound is investigated. A theoretical analysis of the primary and secondary sound fields around a spherical sound source reveals that the natural quiet zones for the spherical source have a shell-shape. Using numerical optimization, quiet zones with other shapes are designed, showing potential for quiet zones with extents that are significantly larger than the well-known limit of a tenth of a wavelength for monopole sources. The paper presents several simulation examples showing quiet zones in various configurations.
Autonomous omnidirectional spacecraft antenna system
NASA Technical Reports Server (NTRS)
Taylor, T. H.
1983-01-01
The development of a low gain Electronically Switchable Spherical Array Antenna is discussed. This antenna provides roughly 7 dBic gain for receive/transmit operation between user satellites and the Tracking and Data Relay Satellite System. When used as a pair, the antenna provides spherical coverage. The antenna was tested in its primary operating modes: directed beam, retrodirective, and Omnidirectional.
X ray microscope assembly and alignment support and advanced x ray microscope design and analysis
NASA Technical Reports Server (NTRS)
Shealy, David L.
1991-01-01
Considerable efforts have been devoted recently to the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft x ray application in microscopy and projection lithography. The spherical Schwarzschild microscope consists of two concentric spherical mirrors configured such that the third order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for x ray applications, it is desirable to have only two reflecting surfaces in a microscope. In order to reduce microscope aberrations and increase the field of view, generalized mirror surface profiles have been considered in this investigation. Based on incoherent and sine wave modulation transfer function (MTF) calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical head reflecting two mirror microscope configurations.
The Safety and Predictability of Implanting Autologous Lenticule Obtained by SMILE for Hyperopia.
Sun, Ling; Yao, Peijun; Li, Meiyan; Shen, Yang; Zhao, Jing; Zhou, Xingtao
2015-06-01
To evaluate the safety, effectiveness, stability, and predictability of implanting autologous lenticules obtained from small incision lenticule extraction for the treatment of hyperopia. Five patients (10 eyes) with one myopic eye and one hyperopic eye were enrolled. The myopic eye was treated with small incision lenticule extraction; a lenticule was extracted and subsequently implanted in the hyperopic eye. Follow-up was at 1 day, 1, 3, 6, and 9 months, and 1 year postoperatively. Patients received a complete ophthalmologic examination at each visit, including uncorrected distance visual acuity, corrected distance visual acuity, anterior segment optical coherence tomography, and corneal topography. There were no complications in any eye during follow-up. Compared with preoperative levels, at the last follow-up visit the eyes with lenticule implantation showed mean spherical equivalent reduced by 5.53 diopters (residual spherical equivalent was +1.13 to -2.63 diopters), mean uncorrected distance visual acuity increased approximately two lines (approximately 20/63 to 20/40 Snellen), and corrected distance visual acuity in 4 (80%) eyes gained one line, 2 (40%) eyes gained two lines, and 1 (20%) eye gained more than two lines. There was no significant difference (P > .05) in spherical equivalent compared with 1 day postoperatively and the last follow-up visit. Corneal topography showed that the lenticule was uniform and located well; anterior segment optical coherence tomography images showed that the lenticule was transparent and the demarcation line was visible. Implanting an autologous lenticule obtained by small incision lenticule extraction for hyperopia might be safe, effective, and stable, but its predictability should be improved in the future. Copyright 2015, SLACK Incorporated.
Modeling the phase behavior of H2S+n-alkane binary mixtures using the SAFT-VR+D approach.
dos Ramos, M Carolina; Goff, Kimberly D; Zhao, Honggang; McCabe, Clare
2008-08-07
A statistical associating fluid theory for potential of variable range has been recently developed to model dipolar fluids (SAFT-VR+D) [Zhao and McCabe, J. Chem. Phys. 2006, 125, 104504]. The SAFT-VR+D equation explicitly accounts for dipolar interactions and their effect on the thermodynamics and structure of a fluid by using the generalized mean spherical approximation (GMSA) to describe a reference fluid of dipolar square-well segments. In this work, we apply the SAFT-VR+D approach to real mixtures of dipolar fluids. In particular, we examine the high-pressure phase diagram of hydrogen sulfide+n-alkane binary mixtures. Hydrogen sulfide is modeled as an associating spherical molecule with four off-center sites to mimic hydrogen bonding and an embedded dipole moment (micro) to describe the polarity of H2S. The n-alkane molecules are modeled as spherical segments tangentially bonded together to form chains of length m, as in the original SAFT-VR approach. By using simple Lorentz-Berthelot combining rules, the theoretical predictions from the SAFT-VR+D equation are found to be in excellent overall agreement with experimental data. In particular, the theory is able to accurately describe the different types of phase behavior observed for these mixtures as the molecular weight of the alkane is varied: type III phase behavior, according to the scheme of classification by Scott and Konynenburg, for the H2S+methane system, type IIA (with the presence of azeotropy) for the H2S+ethane and+propane mixtures; and type I phase behavior for mixtures of H2S and longer n-alkanes up to n-decane. The theory is also able to predict in a qualitative manner the solubility of hydrogen sulfide in heavy n-alkanes.
Glioblastoma: does the pre-treatment geometry matter? A postcontrast T1 MRI-based study.
Pérez-Beteta, Julián; Martínez-González, Alicia; Molina, David; Amo-Salas, Mariano; Luque, Belén; Arregui, Elena; Calvo, Manuel; Borrás, José M; López, Carlos; Claramonte, Marta; Barcia, Juan A; Iglesias, Lidia; Avecillas, Josué; Albillo, David; Navarro, Miguel; Villanueva, José M; Paniagua, Juan C; Martino, Juan; Velásquez, Carlos; Asenjo, Beatriz; Benavides, Manuel; Herruzo, Ismael; Delgado, María Del Carmen; Del Valle, Ana; Falkov, Anthony; Schucht, Philippe; Arana, Estanislao; Pérez-Romasanta, Luis; Pérez-García, Víctor M
2017-03-01
The potential of a tumour's volumetric measures obtained from pretreatment MRI sequences of glioblastoma (GBM) patients as predictors of clinical outcome has been controversial. Mathematical models of GBM growth have suggested a relation between a tumour's geometry and its aggressiveness. A multicenter retrospective clinical study was designed to study volumetric and geometrical measures on pretreatment postcontrast T1 MRIs of 117 GBM patients. Clinical variables were collected, tumours segmented, and measures computed including: contrast enhancing (CE), necrotic, and total volumes; maximal tumour diameter; equivalent spherical CE width and several geometric measures of the CE "rim". The significance of the measures was studied using proportional hazards analysis and Kaplan-Meier curves. Kaplan-Meier and univariate Cox survival analysis showed that total volume [p = 0.034, Hazard ratio (HR) = 1.574], CE volume (p = 0.017, HR = 1.659), spherical rim width (p = 0.007, HR = 1.749), and geometric heterogeneity (p = 0.015, HR = 1.646) were significant parameters in terms of overall survival (OS). Multivariable Cox analysis for OS provided the later two parameters as age-adjusted predictors of OS (p = 0.043, HR = 1.536 and p = 0.032, HR = 1.570, respectively). Patients with tumours having small geometric heterogeneity and/or spherical rim widths had significantly better prognosis. These novel imaging biomarkers have a strong individual and combined prognostic value for GBM patients. • Three-dimensional segmentation on magnetic resonance images allows the study of geometric measures. • Patients with small width of contrast enhancing areas have better prognosis. • The irregularity of contrast enhancing areas predicts survival in glioblastoma patients.
Efficient terrestrial laser scan segmentation exploiting data structure
NASA Astrophysics Data System (ADS)
Mahmoudabadi, Hamid; Olsen, Michael J.; Todorovic, Sinisa
2016-09-01
New technologies such as lidar enable the rapid collection of massive datasets to model a 3D scene as a point cloud. However, while hardware technology continues to advance, processing 3D point clouds into informative models remains complex and time consuming. A common approach to increase processing efficiently is to segment the point cloud into smaller sections. This paper proposes a novel approach for point cloud segmentation using computer vision algorithms to analyze panoramic representations of individual laser scans. These panoramas can be quickly created using an inherent neighborhood structure that is established during the scanning process, which scans at fixed angular increments in a cylindrical or spherical coordinate system. In the proposed approach, a selected image segmentation algorithm is applied on several input layers exploiting this angular structure including laser intensity, range, normal vectors, and color information. These segments are then mapped back to the 3D point cloud so that modeling can be completed more efficiently. This approach does not depend on pre-defined mathematical models and consequently setting parameters for them. Unlike common geometrical point cloud segmentation methods, the proposed method employs the colorimetric and intensity data as another source of information. The proposed algorithm is demonstrated on several datasets encompassing variety of scenes and objects. Results show a very high perceptual (visual) level of segmentation and thereby the feasibility of the proposed algorithm. The proposed method is also more efficient compared to Random Sample Consensus (RANSAC), which is a common approach for point cloud segmentation.
Production of 8.4m segments for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Allen, R. G.; Burge, J. H.; Kim, D. W.; Kingsley, J. S.; Law, K.; Lutz, R. D.; Strittmatter, P. A.; Su, P.; Tuell, M. T.; West, S. C.; Zhou, P.
2012-09-01
Production of segments for the Giant Magellan Telescope is well underway at the Steward Observatory Mirror Lab. We report on the completion of the first 8.4 m off-axis segment, the casting of the second segment, and preparations for manufacture of the remaining segments. The complete set of infrastructure for serial production is in place, including the casting furnace, two 8.4 m capacity grinding and polishing machines, and a 28 m test tower that incorporates four independent measurement systems. The first segment, with 14 mm p-v aspheric departure, is by some measures the most challenging astronomical mirror ever made. Its manufacture took longer than expected, but the result is an excellent figure and demonstration of valuable new systems that will support both fabrication and measurement of the remaining segments. Polishing was done with a 1.2 m stressed lap for smoothing and large-scale figuring, and a series of smaller passive rigid-conformal laps for deterministic figuring on smaller scales. The interferometric measurement produces a null wavefront with a 3-element asymmetric null corrector including a 3.8 m spherical mirror and a computer-generated hologram. In addition to this test, we relied heavily on the new SCOTS slope test with its high accuracy and dynamic range. Evaluation of the measured figure includes simulated active correction using both the 160-actuator mirror support and the alignment degrees of freedom for the off-axis segment.
Alignment positioning mechanism
NASA Technical Reports Server (NTRS)
Fantasia, Peter M. (Inventor)
1991-01-01
An alignment positioning mechanism for correcting and compensating for misalignment of structures to be coupled is disclosed. The mechanism comprises a power screw with a base portion and a threaded shank portion. A mounting fixture is provided for rigidly coupling said base portion to the mounting interface of a supporting structure with the axis of the screw perpendicular thereto. A traveling ball nut threaded on the power screw is formed with an external annular arcuate surface configured in the form of a spherical segment and enclosed by a ball nut housing with a conforming arcuate surface for permitting gimballed motion thereon. The ball nut housing is provided with a mounting surface which is positionable in cooperable engagement with the mounting interface of a primary structure to be coupled to the supporting structure. Cooperative means are provided on the ball nut and ball nut housing, respectively, for positioning the ball nut and ball nut housing in relative gimballed position within a predetermined range of relative angular relationship whereby severe structural stresses due to unequal loadings and undesirable bending moments on the mechanism are avoided.
In-flight performance of the Faint Object Camera of the Hubble Space Telescope
NASA Technical Reports Server (NTRS)
Greenfield, P.; Paresce, F.; Baxter, D.; Hodge, P.; Hook, R.; Jakobsen, P.; Jedrzejewski, R.; Nota, A.; Sparks, W. B.; Towers, N.
1991-01-01
An overview of the Faint Object Camera and its performance to date is presented. In particular, the detector's efficiency, the spatial uniformity of response, distortion characteristics, detector and sky background, detector linearity, spectrography, and operation are discussed. The effect of the severe spherical aberration of the telescope's primary mirror on the camera's point spread function is reviewed, as well as the impact it has on the camera's general performance. The scientific implications of the performance and the spherical aberration are outlined, with emphasis on possible remedies for spherical aberration, hardware remedies, and stellar population studies.
Three-dimensional spherical models of convection in the earth's mantle
NASA Technical Reports Server (NTRS)
Bercovici, Dave; Schubert, Gerald; Glatzmaier, Gary A.
1989-01-01
Three-dimensional spherical models of mantle convection in the earth reveal that upwelling cylindrical plumes and downwelling planar sheets are the primary features of mantle circulation. Thus subduction zones and descending sheetlike slabs in the mantle are fundamental characteristics of thermal convection in a spherical shell and are not merely the consequences of the rigidity of the slabs, which are cooler than the surrounding mantle. Cylindrical mantle plumes that cause hot spots such as Hawaii are probably the only form of active upwelling and are therefore not just secondary convective currents separate from the large-scale mantle circulation.
Tensor scale-based fuzzy connectedness image segmentation
NASA Astrophysics Data System (ADS)
Saha, Punam K.; Udupa, Jayaram K.
2003-05-01
Tangible solutions to image segmentation are vital in many medical imaging applications. Toward this goal, a framework based on fuzzy connectedness was developed in our laboratory. A fundamental notion called "affinity" - a local fuzzy hanging togetherness relation on voxels - determines the effectiveness of this segmentation framework in real applications. In this paper, we introduce the notion of "tensor scale" - a recently developed local morphometric parameter - in affinity definition and study its effectiveness. Although, our previous notion of "local scale" using the spherical model successfully incorporated local structure size into affinity and resulted in measureable improvements in segmentation results, a major limitation of the previous approach was that it ignored local structural orientation and anisotropy. The current approach of using tensor scale in affinity computation allows an effective utilization of local size, orientation, and ansiotropy in a unified manner. Tensor scale is used for computing both the homogeneity- and object-feature-based components of affinity. Preliminary results of the proposed method on several medical images and computer generated phantoms of realistic shapes are presented. Further extensions of this work are discussed.
One-degree-of-freedom spherical model for the passive motion of the human ankle joint.
Sancisi, Nicola; Baldisserri, Benedetta; Parenti-Castelli, Vincenzo; Belvedere, Claudio; Leardini, Alberto
2014-04-01
Mathematical modelling of mobility at the human ankle joint is essential for prosthetics and orthotic design. The scope of this study is to show that the ankle joint passive motion can be represented by a one-degree-of-freedom spherical motion. Moreover, this motion is modelled by a one-degree-of-freedom spherical parallel mechanism model, and the optimal pivot-point position is determined. Passive motion and anatomical data were taken from in vitro experiments in nine lower limb specimens. For each of these, a spherical mechanism, including the tibiofibular and talocalcaneal segments connected by a spherical pair and by the calcaneofibular and tibiocalcaneal ligament links, was defined from the corresponding experimental kinematics and geometry. An iterative procedure was used to optimize the geometry of the model, able to predict original experimental motion. The results of the simulations showed a good replication of the original natural motion, despite the numerous model assumptions and simplifications, with mean differences between experiments and predictions smaller than 1.3 mm (average 0.33 mm) for the three joint position components and smaller than 0.7° (average 0.32°) for the two out-of-sagittal plane rotations, once plotted versus the full flexion arc. The relevant pivot-point position after model optimization was found within the tibial mortise, but not exactly in a central location. The present combined experimental and modelling analysis of passive motion at the human ankle joint shows that a one degree-of-freedom spherical mechanism predicts well what is observed in real joints, although its computational complexity is comparable to the standard hinge joint model.
Objective for EUV microscopy, EUV lithography, and x-ray imaging
Bitter, Manfred; Hill, Kenneth W.; Efthimion, Philip
2016-05-03
Disclosed is an imaging apparatus for EUV spectroscopy, EUV microscopy, EUV lithography, and x-ray imaging. This new imaging apparatus could, in particular, make significant contributions to EUV lithography at wavelengths in the range from 10 to 15 nm, which is presently being developed for the manufacturing of the next-generation integrated circuits. The disclosure provides a novel adjustable imaging apparatus that allows for the production of stigmatic images in x-ray imaging, EUV imaging, and EUVL. The imaging apparatus of the present invention incorporates additional properties compared to previously described objectives. The use of a pair of spherical reflectors containing a concave and convex arrangement has been applied to a EUV imaging system to allow for the image and optics to all be placed on the same side of a vacuum chamber. Additionally, the two spherical reflector segments previously described have been replaced by two full spheres or, more precisely, two spherical annuli, so that the total photon throughput is largely increased. Finally, the range of permissible Bragg angles and possible magnifications of the objective has been largely increased.
Development of the segment alignment maintenance system (SAMS) for the Hobby-Eberly Telescope
NASA Astrophysics Data System (ADS)
Booth, John A.; Adams, Mark T.; Ames, Gregory H.; Fowler, James R.; Montgomery, Edward E.; Rakoczy, John M.
2000-07-01
A sensing and control system for maintaining optical alignment of ninety-one 1-meter mirror segments forming the Hobby-Eberly Telescope (HET) primary mirror array is now under development. The Segment Alignment Maintenance System (SAMS) is designed to sense relative shear motion between each segment edge pair and calculated individual segment tip, tilt, and piston position errors. Error information is sent to the HET primary mirror control system, which corrects the physical position of each segment as often as once per minute. Development of SAMS is required to meet optical images quality specifications for the telescope. Segment misalignment over time is though to be due to thermal inhomogeneity within the steel mirror support truss. Challenging problems of sensor resolution, dynamic range, mechanical mounting, calibration, stability, robust algorithm development, and system integration must be overcome to achieve a successful operational solution.
Development and applications of a flat triangular element for thin laminated shells
NASA Astrophysics Data System (ADS)
Mohan, P.
Finite element analysis of thin laminated shells using a three-noded flat triangular shell element is presented. The flat shell element is obtained by combining the Discrete Kirchhoff Theory (DKT) plate bending element and a membrane element similar to the Allman element, but derived from the Linear Strain Triangular (LST) element. The major drawback of the DKT plate bending element is that the transverse displacement is not explicitly defined within the interior of the element. In the present research, free vibration analysis is performed both by using a lumped mass matrix and a so called consistent mass matrix, obtained by borrowing shape functions from an existing element, in order to compare the performance of the two methods. Several numerical examples are solved to demonstrate the accuracy of the formulation for both small and large rotation analysis of laminated plates and shells. The results are compared with those available in the existing literature and those obtained using the commercial finite element package ABAQUS and are found to be in good agreement. The element is employed for two main applications involving large flexible structures. The first application is the control of thermal deformations of a spherical mirror segment, which is a segment of a multi-segmented primary mirror used in a space telescope. The feasibility of controlling the surface distortions of the mirror segment due to arbitrary thermal fields, using discrete and distributed actuators, is studied. The second application is the analysis of an inflatable structure, being considered by the US Army for housing vehicles and personnel. The updated Lagrangian formulation of the flat shell element has been developed primarily for the nonlinear analysis of the tent structure, since such a structure is expected to undergo large deformations and rotations under the action of environmental loads like the wind and snow loads. The follower effects of the pressure load have been included in the updated Lagrangian formulation of the flat shell element and have been validated using standard examples in the literature involving deformation-dependent pressure loads. The element can be used to obtain the nonlinear response of the tent structure under wind and snow loads. (Abstract shortened by UMI.)
NASA Technical Reports Server (NTRS)
Rakoczy, John; Hall, Drew; Howard, Ricky; Ly, William; Weir, John; Montgomery, Edward; Brantley, Lott W. (Technical Monitor)
2002-01-01
The Segment Alignment Maintenance System (SAMs) was installed on McDonald Observatory's Hobby-Eberly Telescope (HET) in August 2001. The SAMs became fully operational in October 2001. The SAMs uses a system of 480 inductive edge sensors to correct misalignments of the HET's 91 primary mirror segments when the segments are perturbed from their aligned reference positions. A special observer estimated and corrects for the global radius of curvature (GroC) mode, a mode unobservable by the edge sensors. The SAMs edge sensor system and (GroC) estimator are able to maintain HET's primary figure for much longer durations than previously had been observed. Telescope image quality has improved, and the amount of overhead time required from primary mirror alignment has been reduced. This paper gives a functional description of the SAMs control system and presents performance verification data. This paper also describes how the SAMs has improved the operational efficiency of the HET.
A primary mirror metrology system for the GMT
NASA Astrophysics Data System (ADS)
Rakich, A.
2016-07-01
The Giant Magellan Telescope (GMT)1 is a 25 m "doubly segmented" telescope composed of seven 8.4 m "unit Gregorian telescopes", on a common mount. Each primary and secondary mirror segment will ideally lie on the geometrical surface of the corresponding rotationally symmetrical full aperture optical element. Therefore, each primary and conjugated secondary mirror segment will feed a common instrument interface, their focal planes co-aligned and cophased. First light with a subset of four unit telescopes is currently scheduled for 2022. The project is currently considering an important aspect of the assembly, integration and verification (AIV) phase of the project. This paper will discuss a dedicated system to directly characterize the on-sky performance of the M1 segments, independently of the M2 subsystem. A Primary Mirror Metrology System (PMS) is proposed. The main purpose of this system will be to he4lp determine the rotation axis of an instrument rotator (the Gregorian Instrument Rotator or GIR in this case) and then to characterize the deflections and deformations of the M1 segments with respect to this axis as a function of gravity and temperature. The metrology system will incorporate a small (180 mm diameter largest element) prime focus corrector (PFC) that simultaneously feeds a <60" square acquisition and guiding camera field, and a Shack Hartmann wavefront sensor. The PMS is seen as a significant factor in risk reduction during AIV; it allows an on-sky characterization of the primary mirror segments and cells, without the complications of other optical elements. The PMS enables a very useful alignment strategy that constrains each primary mirror segments' optical axes to follow the GIR axis to within a few arc seconds. An additional attractive feature of the incorporation of the PMS into the AIV plan, is that it allows first on-sky telescope operations to occur with a system of considerably less optical and control complexity than the final doubly segmented Gregorian telescope configuration. This paper first discusses the strategic rationale for a PMS. Next the system itself is described in some detail. Finally, some description of the various uses the PMS will be put to during AIV of the M1 segments and subsequent characterization will be described.
Coaxial anode improves sensitivity of gas radiation counters
NASA Technical Reports Server (NTRS)
Kraushaar, W. L.
1974-01-01
Anode wire itself is enclosed by three segments. Two on ends are rejector segments, and middle one is primary charge-detecting segment. Anode wire is made from tungsten and is surrounded by enamel insulation. Enamel is covered by segments of vapor-deposited gold. At one point in center segment, gold layer makes direct contact with anode wire.
Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes
NASA Technical Reports Server (NTRS)
Spechler, Joshua A.; Hoppe, Daniel J.; Sigrist, Norbert; Shi, Fang; Seo, Byoung-Joon; Bikkannavar, Siddarayappa A.
2013-01-01
Segment mirror phasing, a critical step of segment mirror alignment, requires the ability to sense and correct the relative pistons between segments from up to a few hundred microns to a fraction of wavelength in order to bring the mirror system to its full diffraction capability. When sampling the aperture of a telescope, using auto-collimating flats (ACFs) is more economical. The performance of a telescope with a segmented primary mirror strongly depends on how well those primary mirror segments can be phased. One such process to phase primary mirror segments in the axial piston direction is dispersed fringe sensing (DFS). DFS technology can be used to co-phase the ACFs. DFS is essentially a signal fitting and processing operation. It is an elegant method of coarse phasing segmented mirrors. DFS performance accuracy is dependent upon careful calibration of the system as well as other factors such as internal optical alignment, system wavefront errors, and detector quality. Novel improvements to the algorithm have led to substantial enhancements in DFS performance. The Advanced Dispersed Fringe Sensing (ADFS) Algorithm is designed to reduce the sensitivity to calibration errors by determining the optimal fringe extraction line. Applying an angular extraction line dithering procedure and combining this dithering process with an error function while minimizing the phase term of the fitted signal, defines in essence the ADFS algorithm.
Status of mirror segment production for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Burge, J. H.; Davis, J. M.; Kim, D. W.; Kingsley, J. S.; Law, K.; Loeff, A.; Lutz, R. D.; Merrill, C.; Strittmatter, P. A.; Tuell, M. T.; Weinberger, S. N.; West, S. C.
2016-07-01
The Richard F. Caris Mirror Lab at the University of Arizona is responsible for production of the eight 8.4 m segments for the primary mirror of the Giant Magellan Telescope, including one spare off-axis segment. We report on the successful casting of Segment 4, the center segment. Prior to generating the optical surface of Segment 2, we carried out a major upgrade of our 8.4 m Large Optical Generator. The upgrade includes new hardware and software to improve accuracy, safety, reliability and ease of use. We are currently carrying out an upgrade of our 8.4 m polishing machine that includes improved orbital polishing capabilities. We added and modified several components of the optical tests during the manufacture of Segment 1, and we have continued to improve the systems in preparation for Segments 2-8. We completed two projects that were prior commitments before GMT Segment 2: casting and polishing the combined primary and tertiary mirrors for the LSST, and casting and generating a 6.5 m mirror for the Tokyo Atacama Observatory.
Design and manufacture of 8.4 m primary mirror segments and supports for the GMT
NASA Astrophysics Data System (ADS)
Martin, H. M.; Angel, J. R. P.; Burge, J. H.; Cuerden, B.; Davison, W. B.; Johns, M.; Kingsley, J. S.; Kot, L. B.; Lutz, R. D.; Miller, S. M.; Shectman, S. A.; Strittmatter, P. A.; Zhao, C.
2006-06-01
The design, manufacture and support of the primary mirror segments for the GMT build on the successful primary mirror systems of the MMT, Magellan and Large Binocular telescopes. The mirror segment and its support system are based on a proven design, and the experience gained in the existing telescopes has led to significant refinements that will provide even better performance in the GMT. The first 8.4 m segment has been cast at the Steward Observatory Mirror Lab, and optical processing is underway. Measurement of the off-axis surface is the greatest challenge in the manufacture of the segments. A set of tests that meets the requirements has been defined and the concepts have been developed in some detail. The most critical parts of the tests have been demonstrated in the measurement of a 1.7 m off-axis prototype. The principal optical test is a full-aperture, high-resolution null test in which a hybrid reflective-diffractive null corrector compensates for the 14 mm aspheric departure of the off-axis segment. The mirror support uses the same synthetic floatation principle as the MMT, Magellan, and LBT mirrors. Refinements for GMT include 3-axis actuators to accommodate the varying orientations of segments in the telescope.
Xu, Jingjing; Bao, Jinhua; Deng, Jun; Lu, Fan; He, Ji C
2011-07-29
To measure dynamic change characteristics of spatial and temporal variations in the post-blink tear film of normal eyes. A wavefront sensor was used to measure dynamic changes in wavefront aberrations, up to the seventh order, for 10 seconds in a group of 33 normal young adults. Tear menisci were imaged with an anterior segment optical coherence tomography (AS-OCT) system and tear film break-up times (TFBUTs) were determined. Systematic changes in main axis astigmatism (R(2) = 0.933, P < 0.0001), vertical coma (R(2) = 0.935, P < 0.0001) and spherical aberrations (R(2) = 0.879, P = 0.0002) occurred during the 10-second post-blink period. Both lower tear meniscus height and area increased by 10 seconds compared with the initial levels (P < 0.0001 for each). The change of vertical coma had significant correlation with the increase of lower tear meniscus areas during the 10-second post-blink period (R(2) = 0.181, P = 0.014). Subjects with TFBUTs < 15 seconds had significantly increased main axis astigmatism, vertical coma, and spherical aberrations by 10 seconds. Subjects with longer TFBUTs did not have any significant wavefront aberrations during that period. Systematic changes in some Zernike aberrations after blinking are associated with the changes in tear menisci and TFBUT. There was a substantial individual variation in dynamic changes of Zernike aberrations, suggesting the necessity to explore individual differences in tear quality and tear performance. Dynamic wavefront measurement combined with anterior segment optical coherence tomography could provide a useful tool to understand spatial and temporal processes of the tear film in clinical practice.
Inverting Image Data For Optical Testing And Alignment
NASA Technical Reports Server (NTRS)
Shao, Michael; Redding, David; Yu, Jeffrey W.; Dumont, Philip J.
1993-01-01
Data from images produced by slightly incorrectly figured concave primary mirror in telescope processed into estimate of spherical aberration of mirror, by use of algorithm finding nonlinear least-squares best fit between actual images and synthetic images produced by multiparameter mathematical model of telescope optical system. Estimated spherical aberration, in turn, converted into estimate of deviation of reflector surface from nominal precise shape. Algorithm devised as part of effort to determine error in surface figure of primary mirror of Hubble space telescope, so corrective lens designed. Modified versions of algorithm also used to find optical errors in other components of telescope or of other optical systems, for purposes of testing, alignment, and/or correction.
Li, Ang; Zhang, Donghui
2016-03-14
Amphiphilic block copolypeptoids consisting of a hydrophilic poly(N-ethyl glycine) segment and a hydrophobic poly[(N-propargyl glycine)-r-(N-decyl glycine)] random copolymer segment [PNEG-b-P(NPgG-r-NDG), EPgD] have been synthesized by sequential primary amine-initiated ring-opening polymerization (ROP) of the corresponding N-alkyl N-carboxyanhydride monomers. The block copolypeptoids form micelles in water and the micellar core can be cross-linked with a disulfide-containing diazide cross-linker by copper-mediated alkyne-azide cycloaddition (CuAAC) in aqueous solution. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis revealed the formation of spherical micelles with uniform size for both the core-cross-linked micelles (CCLMs) and non-cross-linked micelles (NCLMs) precursors for selective block copolypeptoid polymers. The CCLMs exhibited increased dimensional stability relative to the NCLMs in DMF, a nonselective solvent for the core and corona segments. Micellar dissociation of CCLMs can be induced upon addition of a reducing agent (e.g., dithiothreitol) in dilute aqueous solutions, as verified by a combination of fluorescence spectroscopy, size exclusion chromatography (SEC), and (1)H NMR spectroscopic measurement. Doxorubicin (DOX), an anticancer drug, can be loaded into the hydrophobic core of CCLMs with a maximal 23% drug loading capacity (DLC) and 37% drug loading efficiency (DLE). In vitro DOX release from the CCLMs can be triggered by DTT (10 mM), in contrast to significantly reduced DOX release in the absence of DTT, attesting to the reductively responsive characteristic of the CCLMs. While the CCLMs exhibited minimal cytotoxicity toward HepG2 cancer cells, DOX-loaded CCLMs inhibited the proliferation of the HepG2 cancer cells in a concentration and time dependent manner, suggesting the controlled release of DOX from the DOX-loaded CCLMS in the cellular environment.
NASA Astrophysics Data System (ADS)
Gavrielides, Marios A.; DeFilippo, Gino; Berman, Benjamin P.; Li, Qin; Petrick, Nicholas; Schultz, Kurt; Siegelman, Jenifer
2017-03-01
Computed tomography is primarily the modality of choice to assess stability of nonsolid pulmonary nodules (sometimes referred to as ground-glass opacity) for three or more years, with change in size being the primary factor to monitor. Since volume extracted from CT is being examined as a quantitative biomarker of lung nodule size, it is important to examine factors affecting the performance of volumetric CT for this task. More specifically, the effect of reconstruction algorithms and measurement method in the context of low-dose CT protocols has been an under-examined area of research. In this phantom study we assessed volumetric CT with two different measurement methods (model-based and segmentation-based) for nodules with radiodensities of both nonsolid (-800HU and -630HU) and solid (-10HU) nodules, sizes of 5mm and 10mm, and two different shapes (spherical and spiculated). Imaging protocols included CTDIvol typical of screening (1.7mGy) and sub-screening (0.6mGy) scans and different types of reconstruction algorithms across three scanners. Results showed that radio-density was the factor contributing most to overall error based on ANOVA. The choice of reconstruction algorithm or measurement method did not affect substantially the accuracy of measurements; however, measurement method affected repeatability with repeatability coefficients ranging from around 3-5% for the model-based estimator to around 20-30% across reconstruction algorithms for the segmentation-based method. The findings of the study can be valuable toward developing standardized protocols and performance claims for nonsolid nodules.
Dynamical simulation of E-ELT segmented primary mirror
NASA Astrophysics Data System (ADS)
Sedghi, B.; Muller, M.; Bauvir, B.
2011-09-01
The dynamical behavior of the primary mirror (M1) has an important impact on the control of the segments and the performance of the telescope. Control of large segmented mirrors with a large number of actuators and sensors and multiple control loops in real life is a challenging problem. In virtual life, modeling, simulation and analysis of the M1 bears similar difficulties and challenges. In order to capture the dynamics of the segment subunits (high frequency modes) and the telescope back structure (low frequency modes), high order dynamical models with a very large number of inputs and outputs need to be simulated. In this paper, different approaches for dynamical modeling and simulation of the M1 segmented mirror subject to various perturbations, e.g. sensor noise, wind load, vibrations, earthquake are presented.
Fabrication, Testing, Coating and Alignment of Fast Segmented Optics
2006-05-25
mirror segment, a 100 mm thick Zerodur mirror blank was purchased from Schott. Figure 2 shows the segment and its support for polishing and testing in...Polishing large off-axis segments of fast primary mirrors 2. Testing large segments in an off-axis geometry 3. Alignment of multiple segments of a large... mirror 4. Coatings that reflect high-intensity light without distorting the substrate These technologies are critical because of several unique
Interactive Volumetry Of Liver Ablation Zones.
Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Hann, Alexander; Chen, Xiaojun; Alhonnoro, Tuomas; Pollari, Mika; Schmalstieg, Dieter; Moche, Michael
2015-10-20
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm's results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.
Interactive Volumetry Of Liver Ablation Zones
Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Hann, Alexander; Chen, Xiaojun; Alhonnoro, Tuomas; Pollari, Mika; Schmalstieg, Dieter; Moche, Michael
2015-01-01
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm’s results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow. PMID:26482818
Semi-automatic 3D lung nodule segmentation in CT using dynamic programming
NASA Astrophysics Data System (ADS)
Sargent, Dustin; Park, Sun Young
2017-02-01
We present a method for semi-automatic segmentation of lung nodules in chest CT that can be extended to general lesion segmentation in multiple modalities. Most semi-automatic algorithms for lesion segmentation or similar tasks use region-growing or edge-based contour finding methods such as level-set. However, lung nodules and other lesions are often connected to surrounding tissues, which makes these algorithms prone to growing the nodule boundary into the surrounding tissue. To solve this problem, we apply a 3D extension of the 2D edge linking method with dynamic programming to find a closed surface in a spherical representation of the nodule ROI. The algorithm requires a user to draw a maximal diameter across the nodule in the slice in which the nodule cross section is the largest. We report the lesion volume estimation accuracy of our algorithm on the FDA lung phantom dataset, and the RECIST diameter estimation accuracy on the lung nodule dataset from the SPIE 2016 lung nodule classification challenge. The phantom results in particular demonstrate that our algorithm has the potential to mitigate the disparity in measurements performed by different radiologists on the same lesions, which could improve the accuracy of disease progression tracking.
Interactive Volumetry Of Liver Ablation Zones
NASA Astrophysics Data System (ADS)
Egger, Jan; Busse, Harald; Brandmaier, Philipp; Seider, Daniel; Gawlitza, Matthias; Strocka, Steffen; Voglreiter, Philip; Dokter, Mark; Hofmann, Michael; Kainz, Bernhard; Hann, Alexander; Chen, Xiaojun; Alhonnoro, Tuomas; Pollari, Mika; Schmalstieg, Dieter; Moche, Michael
2015-10-01
Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm’s results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.
Preliminary Analysis of Effect of Random Segment Errors on Coronagraph Performance
NASA Technical Reports Server (NTRS)
Stahl, Mark T.; Shaklan, Stuart B.; Stahl, H. Philip
2015-01-01
Are we alone in the Universe is probably the most compelling science question of our generation. To answer it requires a large aperture telescope with extreme wavefront stability. To image and characterize Earth-like planets requires the ability to block 10(exp 10) of the host stars light with a 10(exp -11) stability. For an internal coronagraph, this requires correcting wavefront errors and keeping that correction stable to a few picometers rms for the duration of the science observation. This requirement places severe specifications upon the performance of the observatory, telescope and primary mirror. A key task of the AMTD project (initiated in FY12) is to define telescope level specifications traceable to science requirements and flow those specifications to the primary mirror. From a systems perspective, probably the most important question is: What is the telescope wavefront stability specification? Previously, we suggested this specification should be 10 picometers per 10 minutes; considered issues of how this specification relates to architecture, i.e. monolithic or segmented primary mirror; and asked whether it was better to have few or many segmented. This paper reviews the 10 picometers per 10 minutes specification; provides analysis related to the application of this specification to segmented apertures; and suggests that a 3 or 4 ring segmented aperture is more sensitive to segment rigid body motion that an aperture with fewer or more segments.
Single-axis four-mirror system: large spherical primary and small fields
NASA Astrophysics Data System (ADS)
Baranne, Andre
1998-08-01
A catoptric corrector of modest size can be used for large spherical primaries, easily integrated at the prime focus, this corrector gives back to the system, aspect and properties of 2-mirrors classical telescopes. In the last few years, progress in active and adaptative optics makes possible a lot of things, progress in measuring distances, new ideas on optical coatings, new materials and so on in a near future, all that makes the instrumentalist dreamy It is said that nobody knows today if the size of 3rd millennium telescopes will be limited or not by a theoretical, physical or technical phenomenon, thus let us imagine but with thoughtfulness because our projects will be surely restricted by financial considerations
Hybrid simplified spherical harmonics with diffusion equation for light propagation in tissues.
Chen, Xueli; Sun, Fangfang; Yang, Defu; Ren, Shenghan; Zhang, Qian; Liang, Jimin
2015-08-21
Aiming at the limitations of the simplified spherical harmonics approximation (SPN) and diffusion equation (DE) in describing the light propagation in tissues, a hybrid simplified spherical harmonics with diffusion equation (HSDE) based diffuse light transport model is proposed. In the HSDE model, the living body is first segmented into several major organs, and then the organs are divided into high scattering tissues and other tissues. DE and SPN are employed to describe the light propagation in these two kinds of tissues respectively, which are finally coupled using the established boundary coupling condition. The HSDE model makes full use of the advantages of SPN and DE, and abandons their disadvantages, so that it can provide a perfect balance between accuracy and computation time. Using the finite element method, the HSDE is solved for light flux density map on body surface. The accuracy and efficiency of the HSDE are validated with both regular geometries and digital mouse model based simulations. Corresponding results reveal that a comparable accuracy and much less computation time are achieved compared with the SPN model as well as a much better accuracy compared with the DE one.
Alignment and Integration Techniques for Mirror Segment Pairs on the Constellation X Telescope
NASA Technical Reports Server (NTRS)
Hadjimichael, Theo; Lehan, John; Olsen, Larry; Owens, Scott; Saha, Timo; Wallace, Tom; Zhang, Will
2007-01-01
We present the concepts behind current alignment and integration techniques for testing a Constellation-X primary-secondary mirror segment pair in an x-ray beam line test. We examine the effects of a passive mount on thin glass x-ray mirror segments, and the issues of mount shape and environment on alignment. We also investigate how bonding and transfer to a permanent housing affects the quality of the final image, comparing predicted results to a full x-ray test on a primary secondary pair.
On-sky performance of the Zernike phase contrast sensor for the phasing of segmented telescopes.
Surdej, Isabelle; Yaitskova, Natalia; Gonte, Frederic
2010-07-20
The Zernike phase contrast method is a novel technique to phase the primary mirrors of segmented telescopes. It has been tested on-sky on a unit telescope of the Very Large Telescope with a segmented mirror conjugated to the primary mirror to emulate a segmented telescope. The theoretical background of this sensor and the algorithm used to retrieve the piston, tip, and tilt information are described. The performance of the sensor as a function of parameters such as star magnitude, seeing, and integration time is discussed. The phasing accuracy has always been below 15 nm root mean square wavefront error under normal conditions of operation and the limiting star magnitude achieved on-sky with this sensor is 15.7 in the red, which would be sufficient to phase segmented telescopes in closed-loop during observations.
Primary aberrations in focused radially polarized vortex beams
NASA Astrophysics Data System (ADS)
Biss, David P.; Brown, T. G.
2004-02-01
We study the effect of primary aberrations on the 3-D polarization of the electric field in a focused lowest order radially polarized beam. A full vector diffraction treatment of the focused beams is used. Attention is given to the effects of primary spherical, astigmatic, and comatic aberrations on the local polarization, Strehl ratio, and aberration induced degradation of the longitudinal field at focus
Dispersed Fringe Sensing Analysis - DFSA
NASA Technical Reports Server (NTRS)
Sigrist, Norbert; Shi, Fang; Redding, David C.; Basinger, Scott A.; Ohara, Catherine M.; Seo, Byoung-Joon; Bikkannavar, Siddarayappa A.; Spechler, Joshua A.
2012-01-01
Dispersed Fringe Sensing (DFS) is a technique for measuring and phasing segmented telescope mirrors using a dispersed broadband light image. DFS is capable of breaking the monochromatic light ambiguity, measuring absolute piston errors between segments of large segmented primary mirrors to tens of nanometers accuracy over a range of 100 micrometers or more. The DFSA software tool analyzes DFS images to extract DFS encoded segment piston errors, which can be used to measure piston distances between primary mirror segments of ground and space telescopes. This information is necessary to control mirror segments to establish a smooth, continuous primary figure needed to achieve high optical quality. The DFSA tool is versatile, allowing precise piston measurements from a variety of different optical configurations. DFSA technology may be used for measuring wavefront pistons from sub-apertures defined by adjacent segments (such as Keck Telescope), or from separated sub-apertures used for testing large optical systems (such as sub-aperture wavefront testing for large primary mirrors using auto-collimating flats). An experimental demonstration of the coarse-phasing technology with verification of DFSA was performed at the Keck Telescope. DFSA includes image processing, wavelength and source spectral calibration, fringe extraction line determination, dispersed fringe analysis, and wavefront piston sign determination. The code is robust against internal optical system aberrations and against spectral variations of the source. In addition to the DFSA tool, the software package contains a simple but sophisticated MATLAB model to generate dispersed fringe images of optical system configurations in order to quickly estimate the coarse phasing performance given the optical and operational design requirements. Combining MATLAB (a high-level language and interactive environment developed by MathWorks), MACOS (JPL s software package for Modeling and Analysis for Controlled Optical Systems), and DFSA provides a unique optical development, modeling and analysis package to study current and future approaches to coarse phasing controlled segmented optical systems.
Active wavefront control challenges of the NASA Large Deployable Reflector (LDR)
NASA Technical Reports Server (NTRS)
Meinel, Aden B.; Meinel, Marjorie P.; Manhart, Paul K.; Hochberg, Eric B.
1989-01-01
The 20-m Large Deployable Reflector will have a segmented primary mirror. Achieving diffraction-limited performance at 50 microns requires correction for the errors of tilt and piston of the primary mirror. This correction can be obtained in two ways, the use of an active primary or a correction at a demagnified pupil of the primary. A critical requirement is the means for measurement of the wavefront error and maintaining phasing during the observation of objects that may be too faint for determining the error. Absolute phasing can only be determined using a cooperative source. Maintenance of phasing can be done with an on-board source. A number of options are being explored as discussed below. The many issues concerning the assessment and control of an active segmented mirror will be addressed with an early construction of the Precision Segmented Reflector testbed.
Active wavefront control challenges of the NASA Large Deployable Reflector (LDR)
NASA Astrophysics Data System (ADS)
Meinel, Aden B.; Meinel, Marjorie P.; Manhart, Paul K.; Hochberg, Eric B.
1989-09-01
The 20-m Large Deployable Reflector will have a segmented primary mirror. Achieving diffraction-limited performance at 50 microns requires correction for the errors of tilt and piston of the primary mirror. This correction can be obtained in two ways, the use of an active primary or a correction at a demagnified pupil of the primary. A critical requirement is the means for measurement of the wavefront error and maintaining phasing during the observation of objects that may be too faint for determining the error. Absolute phasing can only be determined using a cooperative source. Maintenance of phasing can be done with an on-board source. A number of options are being explored as discussed below. The many issues concerning the assessment and control of an active segmented mirror will be addressed with an early construction of the Precision Segmented Reflector testbed.
Automatic knee cartilage delineation using inheritable segmentation
NASA Astrophysics Data System (ADS)
Dries, Sebastian P. M.; Pekar, Vladimir; Bystrov, Daniel; Heese, Harald S.; Blaffert, Thomas; Bos, Clemens; van Muiswinkel, Arianne M. C.
2008-03-01
We present a fully automatic method for segmentation of knee joint cartilage from fat suppressed MRI. The method first applies 3-D model-based segmentation technology, which allows to reliably segment the femur, patella, and tibia by iterative adaptation of the model according to image gradients. Thin plate spline interpolation is used in the next step to position deformable cartilage models for each of the three bones with reference to the segmented bone models. After initialization, the cartilage models are fine adjusted by automatic iterative adaptation to image data based on gray value gradients. The method has been validated on a collection of 8 (3 left, 5 right) fat suppressed datasets and demonstrated the sensitivity of 83+/-6% compared to manual segmentation on a per voxel basis as primary endpoint. Gross cartilage volume measurement yielded an average error of 9+/-7% as secondary endpoint. For cartilage being a thin structure, already small deviations in distance result in large errors on a per voxel basis, rendering the primary endpoint a hard criterion.
Schanzlin, D J
1999-01-01
PURPOSE: Intrastromal corneal ring segments (ICRS) were investigated for safety and reliability in the correction of low to moderate myopic refractive errors. METHODS: Initially, 74 patients with spherical equivalent refractive errors between -1.00 and -4.25 diopters (D) received the ICRS in 1 eye. After 6 months, 51 of these patients received the ICRS in the contralateral eye. The total number of eyes investigated was 125. The outcome measures were uncorrected and best-corrected visual acuity, predictability and stability of the refraction, refractive astigmatism, contrast sensitivity, and endothelial cell morphology. RESULTS: The 89 eyes with 12-month follow-up showed significant improvement with uncorrected visual acuities of 20/16 or better in 37%, 20/20 or better in 62%, and 20/40 or better in 97%. Cycloplegic refraction spherical equivalents showed that 68% of the eyes were within +/- 0.50 D and 90% within +/- 1.00 D of the intended correction. Refractive stability was present by 3 months after the surgery. Only 1 patients had a loss greater than 2 lines or 10 letters of best spectacle-corrected visual acuity, but the patient's acuity was 20/20. Refractive cylinder, contrast sensitivity, and endothelial cell morphology were not adversely affected. The ICRS was removed from the eyes of 6 patients. Three removals were prompted by glare and double images occurring at night; 3 were for nonmedical reasons. All patients returned to within +/- 1.00 D of their preoperative refractive spherical equivalent, and no patients lost more than 1 line of best corrected visual acuity by 3 months after ICRS removal. CONCLUSION: The ICRS safely and reliably corrects myopic refractive errors between -1.00 and -4.50 D. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 PMID:10703146
A method of inversion of satellite magnetic anomaly data
NASA Technical Reports Server (NTRS)
Mayhew, M. A.
1977-01-01
A method of finding a first approximation to a crustal magnetization distribution from inversion of satellite magnetic anomaly data is described. Magnetization is expressed as a Fourier Series in a segment of spherical shell. Input to this procedure is an equivalent source representation of the observed anomaly field. Instability of the inversion occurs when high frequency noise is present in the input data, or when the series is carried to an excessively high wave number. Preliminary results are given for the United States and adjacent areas.
Model-Based Wavefront Control for CCAT
NASA Technical Reports Server (NTRS)
Redding, David; Lou, John Z.; Kissil, Andy; Bradford, Matt; Padin, Steve; Woody, David
2011-01-01
The 25-m aperture CCAT submillimeter-wave telescope will have a primary mirror that is divided into 162 individual segments, each of which is provided with 3 positioning actuators. CCAT will be equipped with innovative Imaging Displacement Sensors (IDS) inexpensive optical edge sensors capable of accurately measuring all segment relative motions. These measurements are used in a Kalman-filter-based Optical State Estimator to estimate wavefront errors, permitting use of a minimum-wavefront controller without direct wavefront measurement. This controller corrects the optical impact of errors in 6 degrees of freedom per segment, including lateral translations of the segments, using only the 3 actuated degrees of freedom per segment. The global motions of the Primary and Secondary Mirrors are not measured by the edge sensors. These are controlled using a gravity-sag look-up table. Predicted performance is illustrated by simulated response to errors such as gravity sag.
Cao, Haifeng; Zhang, Jingxu; Yang, Fei; An, Qichang; Zhao, Hongchao; Guo, Peng
2018-05-01
The Thirty Meter Telescope (TMT) project will design and build a 30-m-diameter telescope for research in astronomy in visible and infrared wavelengths. The primary mirror of TMT is made up of 492 hexagonal mirror segments under active control. The highly segmented primary mirror will utilize edge sensors to align and stabilize the relative piston, tip, and tilt degrees of segments. The support system assembly (SSA) of the segmented mirror utilizes a guide flexure to decouple the axial support and lateral support, while its deformation will cause measurement error of the edge sensor. We have analyzed the theoretical relationship between the segment movement and the measurement value of the edge sensor. Further, we have proposed an error correction method with a matrix. The correction process and the simulation results of the edge sensor will be described in this paper.
Dielectric Covered Planar Antennas
NASA Technical Reports Server (NTRS)
Llombart Juan, Nuria (Inventor); Lee, Choonsup (Inventor); Chattopadhyay, Goutam (Inventor); Gill, John J. (Inventor); Skalare, Anders J. (Inventor); Siegel, Peter H. (Inventor)
2014-01-01
An antenna element suitable for integrated arrays at terahertz frequencies is disclosed. The antenna element comprises an extended spherical (e.g. hemispherical) semiconductor lens, e.g. silicon, antenna fed by a leaky wave waveguide feed. The extended spherical lens comprises a substantially spherical lens adjacent a substantially planar lens extension. A couple of TE/TM leaky wave modes are excited in a resonant cavity formed between a ground plane and the substantially planar lens extension by a waveguide block coupled to the ground plane. Due to these modes, the primary feed radiates inside the lens with a directive pattern that illuminates a small sector of the lens. The antenna structure is compatible with known semiconductor fabrication technology and enables production of large format imaging arrays.
Accurate segmentation of lung fields on chest radiographs using deep convolutional networks
NASA Astrophysics Data System (ADS)
Arbabshirani, Mohammad R.; Dallal, Ahmed H.; Agarwal, Chirag; Patel, Aalpan; Moore, Gregory
2017-02-01
Accurate segmentation of lung fields on chest radiographs is the primary step for computer-aided detection of various conditions such as lung cancer and tuberculosis. The size, shape and texture of lung fields are key parameters for chest X-ray (CXR) based lung disease diagnosis in which the lung field segmentation is a significant primary step. Although many methods have been proposed for this problem, lung field segmentation remains as a challenge. In recent years, deep learning has shown state of the art performance in many visual tasks such as object detection, image classification and semantic image segmentation. In this study, we propose a deep convolutional neural network (CNN) framework for segmentation of lung fields. The algorithm was developed and tested on 167 clinical posterior-anterior (PA) CXR images collected retrospectively from picture archiving and communication system (PACS) of Geisinger Health System. The proposed multi-scale network is composed of five convolutional and two fully connected layers. The framework achieved IOU (intersection over union) of 0.96 on the testing dataset as compared to manual segmentation. The suggested framework outperforms state of the art registration-based segmentation by a significant margin. To our knowledge, this is the first deep learning based study of lung field segmentation on CXR images developed on a heterogeneous clinical dataset. The results suggest that convolutional neural networks could be employed reliably for lung field segmentation.
Dong, Anjie; Hou, Guoling; Sun, Duoxian
2003-10-15
Amphoteric polyurethane (APU) samples used in this paper were composed of hydrophobic soft segments and pendent -COOH and -CH(2)N(CH(3))(2) groups on the hard segments, which present the properties of both amphoteric polyelectrolytes and amphiphilic block copolymers. APU macromolecules can self-assemble into micelles in acidic and basic aqueous media by hydrophobic/hydrophilic interaction. The self-assembly behavior of APU in acidic and basic media was studied by transmission electron microscopy and light scattering methods. The spherical and hollow micelles of APU were observed respectively in acidic and basic aqueous media. The results indicate that the size and size distribution of APU self-assembly micelles largely depend on the ratio of -COOH to -CH(2)N(CH(3))(2) groups, density of ionizable groups, concentration of APU, and types of acid and base in the media.
Computerized Interpretation of Dynamic Breast MRI
2006-05-01
correction, tumor segmentation , extraction of computerized features that help distinguish between benign and malignant lesions, and classification. Our...for assessing tumor extent in 3D. The primary feature used for 3D tumor segmentation is the postcontrast enhancement vector. Tumor segmentation is a...Appendix B. 4. Investigation of methods for automatic tumor segmentation We developed an automatic method for assessing tumor extent in 3D. The
Primary angle closure glaucoma in a myopic kinship.
Hagan, J C; Lederer, C M
1985-03-01
Three related myopic individuals with primary angle closure glaucoma are reported. They had true myopia and not pseudomyopia secondary to increased lenticular index of refraction. We believe one of these individuals (-8.62 spherical equivalent) to have the most myopic case of primary angle closure glaucoma reported in the literature. Although myopia is associated with anatomical factors that offer considerable protection from primary angle closure glaucoma, its presence does not eliminate the possibility of this disease. Laser iridectomy was effective in the treatment of these patients.
Infants Segment Continuous Events Using Transitional Probabilities
ERIC Educational Resources Information Center
Stahl, Aimee E.; Romberg, Alexa R.; Roseberry, Sarah; Golinkoff, Roberta Michnick; Hirsh-Pasek, Kathryn
2014-01-01
Throughout their 1st year, infants adeptly detect statistical structure in their environment. However, little is known about whether statistical learning is a primary mechanism for event segmentation. This study directly tests whether statistical learning alone is sufficient to segment continuous events. Twenty-eight 7- to 9-month-old infants…
Delfino, Ralph J.; Gillen, Daniel L.; Tjoa, Thomas; Staimer, Norbert; Polidori, Andrea; Arhami, Mohammad; Sioutas, Constantinos; Longhurst, John
2011-01-01
Background Air pollutants have not been associated with ambulatory electrocardiographic evidence of ST-segment depression ≥ 1 mm (probable cardiac ischemia). We previously found that markers of primary (combustion-related) organic aerosols and gases were positively associated with circulating biomarkers of inflammation and ambulatory blood pressure in the present cohort panel study of elderly subjects with coronary artery disease. Objectives We specifically aimed to evaluate whether exposure markers of primary organic aerosols and ultrafine particles were more strongly associated with ST-segment depression of ≥ 1 mm than were secondary organic aerosols or PM2.5 (particulate matter with aerodynamic diameter ≤ 2.5 μm) mass. Methods We evaluated relations of air pollutants to ambulatory electrocardiographic evidence of cardiac ischemia over 10 days in 38 subjects without ST depression on baseline electrocardiographs. Exposures were measured outdoors in retirement communities in the Los Angeles basin, including daily size-fractionated particle mass and hourly markers of primary and secondary organic aerosols and gases. Generalized estimating equations were used to estimate odds of hourly ST-segment depression (≥ 1 mm) from hourly air pollution exposures and to estimate relative rates of daily counts of ST-segment depression from daily average exposures, controlling for potential confounders. Results We found significant positive associations of hourly ST-segment depression with markers of combustion-related aerosols and gases averaged 1-hr through 3–4 days, but not secondary (photochemically aged) organic aerosols or ozone. The odds ratio per interquartile increase in 2-day average primary organic carbon (5.2 μg/m3) was 15.4 (95% confidence interval, 3.5–68.2). Daily counts of ST-segment depression were consistently associated with primary combustion markers and 2-day average quasi-ultrafine particles < 0.25 μm. Conclusions Results suggest that exposure to quasi-ultrafine particles and combustion-related pollutants (predominantly from traffic) increase the risk of myocardial ischemia, coherent with our previous findings for systemic inflammation and blood pressure. PMID:20965803
Nilsson, Henrik; Blomqvist, Lennart; Douglas, Lena; Nordell, Anders; Jacobsson, Hans; Hagen, Karin; Bergquist, Annika; Jonas, Eduard
2014-04-01
To evaluate dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) for the assessment of global and segmental liver volume and function in patients with primary sclerosing cholangitis (PSC), and to explore the heterogeneous distribution of liver function in this patient group. Twelve patients with primary sclerosing cholangitis (PSC) and 20 healthy volunteers were examined using DHCE-MRI with Gd-EOB-DTPA. Segmental and total liver volume were calculated, and functional parameters (hepatic extraction fraction [HEF], input relative blood-flow [irBF], and mean transit time [MTT]) were calculated in each liver voxel using deconvolutional analysis. In each study subject, and incongruence score (IS) was constructed to describe the mismatch between segmental function and volume. Among patients, the liver function parameters were correlated to bile duct obstruction and to established scoring models for liver disease. Liver function was significantly more heterogeneously distributed in the patient group (IS 1.0 versus 0.4). There were significant correlations between biliary obstruction and segmental functional parameters (HEF rho -0.24; irBF rho -0.45), and the Mayo risk score correlated significantly with the total liver extraction capacity of Gd-EOB-DTPA (rho -0.85). The study demonstrates a new method to quantify total and segmental liver function using DHCE-MRI in patients with PSC. Copyright © 2013 Wiley Periodicals, Inc.
Rios Velazquez, Emmanuel; Aerts, Hugo J W L; Gu, Yuhua; Goldgof, Dmitry B; De Ruysscher, Dirk; Dekker, Andre; Korn, René; Gillies, Robert J; Lambin, Philippe
2012-11-01
To assess the clinical relevance of a semiautomatic CT-based ensemble segmentation method, by comparing it to pathology and to CT/PET manual delineations by five independent radiation oncologists in non-small cell lung cancer (NSCLC). For 20 NSCLC patients (stages Ib-IIIb) the primary tumor was delineated manually on CT/PET scans by five independent radiation oncologists and segmented using a CT based semi-automatic tool. Tumor volume and overlap fractions between manual and semiautomatic-segmented volumes were compared. All measurements were correlated with the maximal diameter on macroscopic examination of the surgical specimen. Imaging data are available on www.cancerdata.org. High overlap fractions were observed between the semi-automatically segmented volumes and the intersection (92.5±9.0, mean±SD) and union (94.2±6.8) of the manual delineations. No statistically significant differences in tumor volume were observed between the semiautomatic segmentation (71.4±83.2 cm(3), mean±SD) and manual delineations (81.9±94.1 cm(3); p=0.57). The maximal tumor diameter of the semiautomatic-segmented tumor correlated strongly with the macroscopic diameter of the primary tumor (r=0.96). Semiautomatic segmentation of the primary tumor on CT demonstrated high agreement with CT/PET manual delineations and strongly correlated with the macroscopic diameter considered as the "gold standard". This method may be used routinely in clinical practice and could be employed as a starting point for treatment planning, target definition in multi-center clinical trials or for high throughput data mining research. This method is particularly suitable for peripherally located tumors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Analysis of TMT primary mirror control-structure interaction
NASA Astrophysics Data System (ADS)
MacMynowski, Douglas G.; Thompson, Peter M.; Sirota, Mark J.
2008-07-01
The primary mirror control system (M1CS) keeps the 492 segments of the Thirty Meter Telescope primary mirror aligned in the presence of disturbances. A global position control loop uses feedback from inter-segment edge sensors to three actuators behind each segment that control segment piston, tip and tilt. If soft force actuators are used (e.g. voice-coil), then in addition to the global position loop there will be a local servo loop to provide stiffness. While the M1 control system at Keck compensates only for slow disturbances such as gravity and thermal variations, the M1CS for TMT will need to provide some compensation for higher frequency wind disturbances in order to meet stringent error budget targets. An analysis of expected high-wavenumber wind forces on M1 suggests that a 1Hz control bandwidth is required for the global feedback of segment edge-sensorbased position information in order to minimize high spatial frequency segment response for both seeing-limited and adaptive optics performance. A much higher bandwidth is required from the local servo loop to provide adequate stiffness to wind or acoustic disturbances. A related paper presents the control designs for the local actuator servo loops. The disturbance rejection requirements would not be difficult to achieve for a single segment, but the structural coupling between segments mounted on a flexible mirror cell results in controlstructure interaction (CSI) that limits the achievable bandwidth. Using a combination of simplified modeling to build intuition and the full telescope finite element model for verification, we present designs and analysis for both the local servo loop and global loop demonstrating sufficient bandwidth and resulting wind-disturbance rejection despite the presence of CSI.
NASA Astrophysics Data System (ADS)
Ravat, D.; Purucker, M.; Olsen, N.; Finlay, C.
2017-12-01
We derive new models of the lunar crustal magnetic field at the lunar surface with data from Lunar Prospector (LP) and SELENE/Kaguya (K) satellite using a global set of 35820 1° equal area monopoles (O'Brien and Parker, 1994; Olsen et al., 2017). The resulting fields have similar features to surface fields obtained by Tsunakawa et al. (2015) using 230 subset regions and the primary differences are due to our stringent data selection (see below). The use of monopoles allows closer spacing than dipoles with lesser amount of regularization and moderate cluster computer resources. We use the scheme of iteratively reweighted least-squares inversion to compute the initial model. Then the amplitudes of these monopoles are determined by minimizing the misfit to the components together with the global average of |Br| at the ellipsoid surface (i.e. applying a L1 model regularization of Br). In a final step we transform the point-source representation to a spherical harmonic expansion. We extract high quality data segments using a processing scheme based on internal/external dipole field removal, low order polynomial removal, and a new processing scheme called Joint Equivalent Source Cross-validation. In the cross-validation procedure we analyze the fit of modeled components to data in 10° latitudinal segments from an inversion of triplets of nearby passes to a single set of dipoles along the passes. We evaluate the fit using four criteria in each segment: correlation coefficient, amplitude ratio, RMS of the misfit, and standard deviation of field values themselves. We fine-tune the criteria to the choice we would have made in visually retaining pass segments and this yields a global dataset of more than 2.87 million (x 3 components) points at altitudes <60 km. The selected Lunar Prospector and Kaguya magnetic data independently show similar features and statistics for altitudes, observed and modeled components, and their misfit (number of observation locations: LP 1.8 million and K 1.07 million x 3 components). We use these data to make a regional assessment of key magnetic features on the Moon (including impacts and swirls), the depth of magnetization of regional sources, and source parameters of isolated anomalies.
Nishihara, Hidenori; Stanyon, Roscoe; Kusumi, Junko; Hirai, Hirohisa
2018-01-01
Abstract Rod cells of many nocturnal mammals have a “non-standard” nuclear architecture, which is called the inverted nuclear architecture. Heterochromatin localizes to the central region of the nucleus. This leads to an efficient light transmission to the outer segments of photoreceptors. Rod cells of diurnal mammals have the conventional nuclear architecture. Owl monkeys (genus Aotus) are the only taxon of simian primates that has a nocturnal or cathemeral lifestyle, and this adaptation is widely thought to be secondary. Their rod cells were shown to exhibit an intermediate chromatin distribution: a spherical heterochromatin block was found in the central region of the nucleus although it was less complete than that of typical nocturnal mammals. We recently demonstrated that the primary DNA component of this heterochromatin block was OwlRep, a megasatellite DNA consisting of 187-bp-long repeat units. However, the origin of OwlRep was not known. Here we show that OwlRep was derived from HSAT6, a simple repeat sequence found in the centromere regions of human chromosomes. HSAT6 occurs widely in primates, suggesting that it was already present in the last common ancestor of extant primates. Notably, Strepsirrhini and Tarsiformes apparently carry a single HSAT6 copy, whereas many species of Simiiformes contain multiple copies. Comparison of nucleotide sequences of these copies revealed the entire process of the OwlRep formation. HSAT6, with or without flanking sequences, was segmentally duplicated in New World monkeys. Then, in the owl monkey linage after its divergence from other New World monkeys, a copy of HSAT6 was tandemly amplified, eventually forming a megasatellite DNA. PMID:29294004
Reverse genetics studies on the filamentous morphology of influenza A virus.
Bourmakina, Svetlana V; García-Sastre, Adolfo
2003-03-01
We have investigated the genetic determinants responsible for the filamentous morphology of influenza A viruses, a property characteristic of primary virus isolates. A plasmid-based reverse genetics system was used to transfer the M segment of influenza A/Udorn/72 (H3N2) virus into influenza A/WSN/33 (H1N1) virus. While WSN virions display spherical morphology, recombinant WSN-Mud virus acquired the ability of the parental Udorn strain to form filamentous virus particles. This was determined by immunofluorescence studies in infected MDCK cells and by electron microscopy of purified virus particles. To determine the gene product within the M segment responsible for filamentous virus morphology, we generated four recombinant viruses carrying different sets of M1 and M2 genes from WSN or Udorn strains in a WSN background. These studies revealed that the M1 gene of Udorn, independently of the origin of the M2 gene, conferred filamentous budding properties and filamentous virus morphology to the recombinant viruses. We also constructed two WSN viruses encoding chimeric M1 proteins containing the amino-terminal 1-162 amino acids or the carboxy-terminal 163-252 amino acids of the Udorn M1 protein. Neither of these two viruses acquired filamentous phenotypes, indicating that both amino- and carboxy-terminal domains of the M1 protein contribute to filamentous virus morphology. We next rescued seven mutant WSN-M1ud viruses containing Udorn M1 proteins carrying single amino acid substitutions corresponding to the seven amino acid differences with the M1 protein of WSN virus. Characterization of these recombinant viruses revealed that amino acid residues 95 and 204 are critical in determining filamentous virus particle formation.
ERIC Educational Resources Information Center
Shaw, John M.; Sheahen, Thomas P.
1994-01-01
Describes the theory behind the workings of the Hubble Space Telescope, the spherical aberration in the primary mirror that caused a reduction in image quality, and the corrective device that compensated for the error. (JRH)
Philip, Krupa; Martinez, Aldo; Ho, Arthur; Conrad, Fabian; Ale, Jit; Mitchell, Paul; Sankaridurg, Padmaja
2012-01-01
Total ocular higher order aberrations and corneal topography of myopic, emmetropic and hyperopic eyes of 675 adolescents (16.9 ± 0.7 years) were measured after cycloplegia using COAS aberrometer and Medmont videokeratoscope. Corneal higher order aberrations were computed from the corneal topography maps and lenticular (internal) higher order aberrations derived by subtraction of corneal aberrations from total ocular aberrations. Aberrations were measured for a pupil diameter of 5mm. Multivariate analysis of variance followed by multiple regression analysis found significant difference in the fourth order aberrations (SA RMS, primary spherical aberration coefficient) between the refractive error groups. Hyperopic eyes (+0.083 ± 0.05 μm) had more positive total ocular primary spherical aberration compared to emmetropic (+0.036 ± 0.04 μm) and myopic eyes (low myopia=+0.038 ± 0.05 μm, moderate myopia=+0.026 ± 0.06 μm) (p<0.05). No difference was observed for the anterior corneal spherical aberration. Significantly less negative lenticular spherical aberration was observed for the hyperopic eyes (-0.038 ± 0.05 μm) than myopic (low myopia=-0.088 ± 0.04 μm, moderate myopia=-0.095 ± 0.05 μm) and emmetropic eyes (-0.081 ± 0.04 μm) (p<0.05). These findings suggest the existence of differences in the characteristics of the crystalline lens (asphericity, curvature and gradient refractive index) of hyperopic eyes versus other eyes. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
O'Donoghue, Darragh E.; O'Connor, James; Crause, Lisa A.; Strumpfer, Francois; Strydom, Ockert J.; Brink, Janus D.; Sass, Craig; Wiid, Eben; Atad-Ettedgui, Eli
2010-07-01
The construction of the Southern African Large Telescope (SALT) was largely completed by the end of 2005. At the beginning of 2006, it was realized that the telescope's image quality suffered from optical aberrations, chiefly a focus gradient across the focal plane, but also accompanied by astigmatism and higher order aberrations. In the previous conference in this series, a paper was presented describing the optical system engineering investigation which had been conducted to diagnose the problem. This investigation exonerated the primary mirror as the cause, as well as the science instruments, and was isolated to the interface between the telescope and a major optical sub-system, the spherical aberration corrector (SAC). This is a complex sub-system of four aspheric mirrors which corrects the spherical aberration of the 11-m primary mirror. In the last two years, a solution to this problem was developed which involved removing the SAC from the telescope, installing a modification of the SAC/telescope interface, re-aligning and testing the four SAC mirrors and re-installation on the telescope. This paper describes the plan, discusses the details and shows progress to date and the current status.
Segmenting Michigan tourists based on distance traveled
Xiamei Xu; Tsao-Fang Yuan; Edwin Gomez; Joseph D. Fridgen
1998-01-01
The purpose of this study was to segment Michigan travelers into short, medium and long distance traveler groups by distance that they traveled from home to a primary destination in Michigan, and to compare travel behavior, trip characteristics and sociodemographics among these segments. Significant differences were identified in past trip experiences in Michigan,...
Scope of inextensible frame hypothesis in local action analysis of spherical reservoirs
NASA Astrophysics Data System (ADS)
Vinogradov, Yu. I.
2017-05-01
Spherical reservoirs, as objects perfect with respect to their weight, are used in spacecrafts, where thin-walled elements are joined by frames into multifunction structures. The junctions are local, which results in origination of stress concentration regions and the corresponding rigidity problems. The thin-walled elements are reinforced by frame to decrease the stresses in them. To simplify the analysis of the mathematical model of common deformation of the shell (which is a mathematical idealization of the reservoir) and the frame, the assumption that the frame axial line is inextensible is used widely (in particular, in the manual literature). The unjustified use of this assumption significantly distorts the concept of the stress-strain state. In this paper, an example of a lens-shaped structure formed as two spherical shell segments connected by a frame of square profile is used to carry out a numerical comparative analysis of the solutions with and without the inextensible frame hypothesis taken into account. The scope of the hypothesis is shown depending on the structure geometric parameters and the load location degree. The obtained results can be used to determine the stress-strain state of the thin-walled structure with an a priori prescribed error, for example, in research and experimental design of aerospace systems.
Xu, Renfeng; Bradley, Arthur; Thibos, Larry N.
2013-01-01
Purpose We tested the hypothesis that pupil apodization is the basis for central pupil bias of spherical refractions in eyes with spherical aberration. Methods We employed Fourier computational optics in which we vary spherical aberration levels, pupil size, and pupil apodization (Stiles Crawford Effect) within the pupil function, from which point spread functions and optical transfer functions were computed. Through-focus analysis determined the refractive correction that optimized retinal image quality. Results For a large pupil (7 mm), as spherical aberration levels increase, refractions that optimize the visual Strehl ratio mirror refractions that maximize high spatial frequency modulation in the image and both focus a near paraxial region of the pupil. These refractions are not affected by Stiles Crawford Effect apodization. Refractions that optimize low spatial frequency modulation come close to minimizing wavefront RMS, and vary with level of spherical aberration and Stiles Crawford Effect. In the presence of significant levels of spherical aberration (e.g. C40 = 0.4 µm, 7mm pupil), low spatial frequency refractions can induce −0.7D myopic shift compared to high SF refraction, and refractions that maximize image contrast of a 3 cycle per degree square-wave grating can cause −0.75D myopic drift relative to refractions that maximize image sharpness. Discussion Because of small depth of focus associated with high spatial frequency stimuli, the large change in dioptric power across the pupil caused by spherical aberration limits the effective aperture contributing to the image of high spatial frequencies. Thus, when imaging high spatial frequencies, spherical aberration effectively induces an annular aperture defining that portion of the pupil contributing to a well-focused image. As spherical focus is manipulated during the refraction procedure, the dimensions of the annular aperture change. Image quality is maximized when the inner radius of the induced annulus falls to zero, thus defining a circular near paraxial region of the pupil that determines refraction outcome. PMID:23683093
Míguez, J M; Piñeiro, M M; Algaba, J; Mendiboure, B; Torré, J P; Blas, F J
2015-11-05
The high-pressure phase diagrams of the tetrahydrofuran(1) + carbon dioxide(2), + methane(2), and + water(2) mixtures are examined using the SAFT-VR approach. Carbon dioxide molecule is modeled as two spherical segments tangentially bonded, water is modeled as a spherical segment with four associating sites to represent the hydrogen bonding, methane is represented as an isolated sphere, and tetrahydrofuran is represented as a chain of m tangentially bonded spherical segments. Dispersive interactions are modeled using the square-well intermolecular potential. In addition, two different molecular model mixtures are developed to take into account the subtle balance between water-tetrahydrofuran hydrogen-bonding interactions. The polar and quadrupolar interactions present in water, tetrahydrofuran, and carbon dioxide are treated in an effective way via square-well potentials of variable range. The optimized intermolecular parameters are taken from the works of Giner et al. (Fluid Phase Equil. 2007, 255, 200), Galindo and Blas (J. Phys. Chem. B 2002, 106, 4503), Patel et al. (Ind. Eng. Chem. Res. 2003, 42, 3809), and Clark et al. (Mol. Phys. 2006, 104, 3561) for tetrahydrofuran, carbon dioxide, methane, and water, respectively. The phase diagrams of the binary mixtures exhibit different types of phase behavior according to the classification of van Konynenburg and Scott, ranging from types I, III, and VI phase behavior for the tetrahydrofuran(1) + carbon dioxide(2), + methane(2), and + water(2) binary mixtures, respectively. This last type is characterized by the presence of a Bancroft point, positive azeotropy, and the so-called closed-loop curves that represent regions of liquid-liquid immiscibility in the phase diagram. The system exhibits lower critical solution temperatures (LCSTs), which denote the lower limit of immiscibility together with upper critical solution temperatures (UCSTs). This behavior is explained in terms of competition between the incompatibility with the alkyl parts of the tetrahydrofuran ring chain and the hydrogen bonding between water and the ether group. A minimum number of unlike interaction parameters are fitted to give the optimal representation of the most representative features of the binary phase diagrams. In the particular case of tetrahydrofuran(1) + water(2), two sets of intermolecular potential model parameters are proposed to describe accurately either the hypercritical point associated with the closed-loop liquid-liquid immiscibility region or the location of the mixture lower- and upper-critical end-points. The theory is not only able to predict the type of phase behavior of each mixture, but also provides a reasonably good description of the global phase behavior whenever experimental data are available.
Dynamic force response of spherical hydrostatic journal bearing for cryogenic applications
NASA Technical Reports Server (NTRS)
Sanandres, Luis
1994-01-01
Hydrostatic Journal Bearings (HJB's) are reliable and resilient fluid film rotor support elements ideal to replace roller bearings in cryogenic turbomachinery. HJB' will be used for primary space-power applications due to their long lifetime, low friction and wear, large load capacity, large direct stiffness, and damping force coefficients. An analysis for the performance characteristics of turbulent flow, orifice compensated, spherical hydrostatic journal bearings (HJB's) is presented. Spherical bearings allow tolerance for shaft misalignment without force performance degradation and have also the ability to support axial loads. The spherical HJB combines these advantages to provide a bearing design which could be used efficiently on high performance turbomachinery. The motion of a barotropic liquid on the thin film bearing lands is described by bulk-flow mass and momentum equations. These equations are solved numerically using an efficient CFD method. Numerical predictions of load capacity and force coefficients for a 6 recess, spherical HJB in a LO2 environment are presented. Fluid film axial forces and force coefficients of a magnitude about 20% of the radial load capacity are predicted for the case analyzed. Fluid inertia effects, advective and centrifugal, are found to affect greatly the static and dynamic force performance of the bearing studied.
Wang, Ying; Chen, Yajuan; Ding, Liping; Zhang, Jiewei; Wei, Jianhua; Wang, Hongzhi
2016-01-01
The vertical segments of Populus stems are an ideal experimental system for analyzing the gene expression patterns involved in primary and secondary growth during wood formation. Suitable internal control genes are indispensable to quantitative real time PCR (qRT-PCR) assays of gene expression. In this study, the expression stability of eight candidate reference genes was evaluated in a series of vertical stem segments of Populus tomentosa. Analysis through software packages geNorm, NormFinder and BestKeeper showed that genes ribosomal protein (RP) and tubulin beta (TUBB) were the most unstable across the developmental stages of P. tomentosa stems, and the combination of the three reference genes, eukaryotic translation initiation factor 5A (eIF5A), Actin (ACT6) and elongation factor 1-beta (EF1-beta) can provide accurate and reliable normalization of qRT-PCR analysis for target gene expression in stem segments undergoing primary and secondary growth in P. tomentosa. These results provide crucial information for transcriptional analysis in the P. tomentosa stem, which may help to improve the quality of gene expression data in these vertical stem segments, which constitute an excellent plant system for the study of wood formation.
NASA's James Webb Space Telescope Primary Mirror Fully Assembled
2016-02-04
The 18th and final primary mirror segment is installed on what will be the biggest and most powerful space telescope ever launched. The final mirror installation Wednesday at NASA’s Goddard Space Flight Center in Greenbelt, Maryland marks an important milestone in the assembly of the agency’s James Webb Space Telescope. “Scientists and engineers have been working tirelessly to install these incredible, nearly perfect mirrors that will focus light from previously hidden realms of planetary atmospheres, star forming regions and the very beginnings of the Universe,” said John Grunsfeld, associate administrator for NASA’s Science Mission Directorate in Washington. “With the mirrors finally complete, we are one step closer to the audacious observations that will unravel the mysteries of the Universe.” Using a robotic arm reminiscent of a claw machine, the team meticulously installed all of Webb's primary mirror segments onto the telescope structure. Each of the hexagonal-shaped mirror segments measures just over 4.2 feet (1.3 meters) across -- about the size of a coffee table -- and weighs approximately 88 pounds (40 kilograms). Once in space and fully deployed, the 18 primary mirror segments will work together as one large 21.3-foot diameter (6.5-meter) mirror. Credit: NASA/Goddard/Chris Gunn Credits: NASA/Chris Gunn
Faint Object Spectrograph (FOS) early performance
NASA Technical Reports Server (NTRS)
Harms, Richard; Fitch, John
1991-01-01
The on-orbit performance of the HST + FOS instrument is described and illustrated with examples of initial scientific results. The effects of the spherical aberration from the misfiguring of the HST primary mirror upon isolated point sources and in complex fields such as the nuclei of galaxies are analyzed. Possible means for eliminating the effects of spherical aberration are studied. Concepts include using image enhancement software to extract maximum spatial and spectral information from the existing data as well as several options to repair or compensate for the HST's optical performance. In particular, it may be possible to install corrective optics into the HST which will eliminate the spherical aberration for the FOS and some of the other instruments. The more promising ideas and calculations of the expected improvements in performance are briefly described.
Hybrid RF / Optical Communication Terminal with Spherical Primary Optics for Optical Reception
NASA Technical Reports Server (NTRS)
Charles, Jeffrey R.; Hoppe, Daniel H.; Sehic, Asim
2011-01-01
Future deep space communications are likely to employ not only the existing RF uplink and downlink, but also a high capacity optical downlink. The Jet Propulsion Laboratory (JPL) is currently investigating the benefits of a ground based hybrid RF and deep space optical terminal based on limited modification of existing 34 meter antenna designs. The ideal design would include as large an optical aperture as technically practical and cost effective, cause minimal impact to RF performance, and remain cost effective even when compared to a separate optical terminal of comparable size. Numerous trades and architectures have been considered, including shared RF and optical apertures having aspheric optics and means to separate RF and optical signals, plus, partitioned apertures in which various zones of the primary are dedicated to optical reception. A design based on the latter is emphasized in this paper, employing spherical primary optics and a new version of a "clamshell" corrector that is optimized to fit within the limited space between the antenna sub-reflector and the existing apex structure that supports the subreflector. The mechanical design of the hybrid accommodates multiple spherical primary mirror panels in the central 11 meters of the antenna, and integrates the clamshell corrector and optical receiver modules with antenna hardware using existing attach points to the maximum extent practical. When an optical collection area is implemented on a new antenna, it is possible to design the antenna structure to accommodate the additional weight of optical mirrors providing an equivalent aperture of several meters diameter. The focus of our near term effort is to use optics with the 34 meter DSS-13 antenna at Goldstone to demonstrate spatial optical acquisition and tracking capability using an optical system that is temporarily integrated into the antenna.
Distortion of ultrashort pulses caused by aberrations
NASA Astrophysics Data System (ADS)
Horváth, Z. L.; Kovács, A. P.; Bor, Zs.
The effect of the primary wave aberrations (spherical aberration, astigmatism and coma) on ultrashort pulses is studied by the Nijboer-Zernike theory. The results of the geometrical and the wave optical treatments are compared.
Ethylene glycol assisted spray pyrolysis for the synthesis of hollow BaFe12O19 spheres
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, X; Park, J; Hong, YK
2015-04-01
Hollow spherical BaFe12O19 particles were synthesized by spray pyrolysis from a solution containing ethylene glycol (EG) and precursors at 1000 degrees C. The effects of EG concentration on particle morphology, crystallinity and magnetic properties were investigated. The hollow spherical particles were found to consist of primary particles, and higher EG concentration led to a bigger primary particle size. EG concentration did not show much effect on the hollow particle size. Better crystallinity and higher magnetic coercivity were obtained with higher EG concentration, which is attributed to further crystallization with the heat produced from EG combustion. Saturation magnetization (emu/g) decreased withmore » increasing EG concentration due to residual carbon from EG incomplete combustion, contributing as a non-magnetic phase to the particles. Published by Elsevier B.V.« less
The Contribution of Segmental and Suprasegmental Phonology to Reading Comprehension
Veenendaal, Nathalie J.; Groen, Margriet A.; Verhoeven, Ludo
2016-01-01
The aim of the present study was to examine the relation between decoding and segmental and suprasegmental phonology, and their contribution to reading comprehension, in the upper primary grades. Following a longitudinal design, the performance of 99 Dutch primary school children on phonological awareness (segmental phonology) and text reading prosody (suprasegmental phonology) in fourth-grade and fifth-grade, and reading comprehension in sixth-grade were examined. In addition, decoding efficiency as a general assessment of reading was examined. Structural path modeling firstly showed that the relation between decoding efficiency and both measures of phonology from fourth- to fifth grade was unidirectional. Secondly, the relation between decoding in fourth- and fifth-grade and reading comprehension in sixth-grade became indirect when segmental and suprasegmental phonology were added to the model. Both factors independently exerted influence on later reading comprehension. This leads to the conclusion that not only segmental, but also suprasegmental phonology, contributes substantially to children's reading development. PMID:27551159
Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.
Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon
2016-04-01
To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Gulyaev, P.; Jordan, V.; Gulyaev, I.; Dolmatov, A.
2017-05-01
The paper presents the analysis of the recorded tracks of high-velocity emission in the air-argon plasma flow during breaking up of tungsten microdroplets. This new physical effect of optical emission involves two stages. The first one includes thermionic emission of electrons from the surface of the melted tungsten droplet of 100-200 μm size and formation of the charged sphere of 3-5 mm diameter. After it reaches the breakdown electric potential, it collapses and produces a spherical shock wave and luminous radiation. The second stage includes previously unknown physical phenomenon of narrowly directed energy jet with velocity exceeding 4000 m/s from the surface of the tungsten droplet. The luminous spherical collapse and high-velocity jets were recorded using CMOS photo-array operating in a global shutter charge storage mode. Special features of the CMOS array scanning algorithm affect formation of distinctive signs of the recorded tracks, which stay invariant to trace transform (TT) with specific functional. The series of concentric circles were adopted as primitive object models (patterns) used in TT at the spherical collapse stage and linear segment of fixed thickness - at the high-velocity emission stage. The two invariants of the physical object, motion velocity and optical brightness distribution in the motion front, were adopted as desired identification features of tracks. The analytical expressions of the relation of 2D TT parameters and physical object motion invariants were obtained. The equations for spherical collapse stage correspond to Radon-Nikodym transform.
NASA Astrophysics Data System (ADS)
Sanatkhani, Soroosh; Oladosu, Michael; Chera, Karandeep; Nedios, Sotirios; Menon, Prahlad G.
2018-03-01
Pulmonary vein isolation (PVI) is an established procedure for atrial fibrillation (AF) patients. Pre-procedural screening is necessary prior to PVI in order to reduce the likelihood of AF recurrence and improve overall success rate of the procedure. However, current reliable methods to determine AF triggers are invasive. In this paper, we present an approach to relate the regional characteristics of left atrial (LA) shape to existence of low-voltage areas (LVA) which indicate the presence of scar in invasive exams. A cohort of 29 AF patient-specific clinical images were each segmented into 3D surface bodies representing the LA. Iterative closest point based similarity transformation was used to find the best fit sphere to each patient-specific LA and the mean deviation of LA wall to this sphere of best fit was determined using a signed point-to-surface regional distance metric. Regional departure from the best-fit sphere was reduced into a metric of global LA sphericity. Next, the LA was divided into six regions to perform an analysis of regional sphericity. Regional sphericity analysis revealed that sphericity of the inferior-posterior LA region was found to be related to several clinical variables, including a direct correlation with body mass index (BMI) and an inverse correlation with left ventricular ejection fraction (EF), which presents a diseased heart that has been asymmetrically inflated. Our observations therefore demonstrate promise in being leveraged as a non-invasive patient selection tool to increase the success rate of PVI procedures.
Water window imaging x ray microscope
NASA Technical Reports Server (NTRS)
Hoover, Richard B. (Inventor)
1992-01-01
A high resolution x ray microscope for imaging microscopic structures within biological specimens has an optical system including a highly polished primary and secondary mirror coated with identical multilayer coatings, the mirrors acting at normal incidence. The coatings have a high reflectivity in the narrow wave bandpass between 23.3 and 43.7 angstroms and have low reflectivity outside of this range. The primary mirror has a spherical concave surface and the secondary mirror has a spherical convex surface. The radii of the mirrors are concentric about a common center of curvature on the optical axis of the microscope extending from the object focal plane to the image focal plane. The primary mirror has an annular configuration with a central aperture and the secondary mirror is positioned between the primary mirror and the center of curvature for reflecting radiation through the aperture to a detector. An x ray filter is mounted at the stage end of the microscope, and film sensitive to x rays in the desired band width is mounted in a camera at the image plane of the optical system. The microscope is mounted within a vacuum chamber for minimizing the absorption of x rays in air from a source through the microscope.
NASA Astrophysics Data System (ADS)
Lee, Sang Joon; Seo, Kyung Won; Choi, Yong Seok; Sohn, Myong Hwan
2011-06-01
A digital holographic microscope is employed to measure the 3D motion of free-swimming microorganisms. The focus function used to quantify image sharpness provides a better depth-directional accuracy with a smaller depth-of-focus compared with the intensity method in determining the depth-directional position of spherical particles of various diameters. The focus function is then applied to measure the 3D positions of free-swimming microorganisms, namely dinoflagellates C. polykrikoides and P. minimum. Both automatic segmentation and proper selection of a focus function for a selected segment are important processes in measuring the positional information of two free-swimming microorganisms of different shapes with various width-to-length ratios. The digital holographic microscopy technique improved in this work is useful for measuring 3D swimming trajectories, velocities and attitudes of hundreds of microorganisms simultaneously. It also exhibits exceptional depth-directional accuracy.
Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment
NASA Technical Reports Server (NTRS)
Whitman, Tony L.; Wells, Conrad; Hadaway, James; Knight, J. Scott; Lunt, Sharon
2016-01-01
After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.
Fault segmentation: New concepts from the Wasatch Fault Zone, Utah, USA
Duross, Christopher; Personius, Stephen F.; Crone, Anthony J.; Olig, Susan S.; Hylland, Michael D.; Lund, William R.; Schwartz, David P.
2016-01-01
The question of whether structural segment boundaries along multisegment normal faults such as the Wasatch fault zone (WFZ) act as persistent barriers to rupture is critical to seismic hazard analyses. We synthesized late Holocene paleoseismic data from 20 trench sites along the central WFZ to evaluate earthquake rupture length and fault segmentation. For the youngest (<3 ka) and best-constrained earthquakes, differences in earthquake timing across prominent primary segment boundaries, especially for the most recent earthquakes on the north-central WFZ, are consistent with segment-controlled ruptures. However, broadly constrained earthquake times, dissimilar event times along the segments, the presence of smaller-scale (subsegment) boundaries, and areas of complex faulting permit partial-segment and multisegment (e.g., spillover) ruptures that are shorter (~20–40 km) or longer (~60–100 km) than the primary segment lengths (35–59 km). We report a segmented WFZ model that includes 24 earthquakes since ~7 ka and yields mean estimates of recurrence (1.1–1.3 kyr) and vertical slip rate (1.3–2.0 mm/yr) for the segments. However, additional rupture scenarios that include segment boundary spatial uncertainties, floating earthquakes, and multisegment ruptures are necessary to fully address epistemic uncertainties in rupture length. We compare the central WFZ to paleoseismic and historical surface ruptures in the Basin and Range Province and central Italian Apennines and conclude that displacement profiles have limited value for assessing the persistence of segment boundaries but can aid in interpreting prehistoric spillover ruptures. Our comparison also suggests that the probabilities of shorter and longer ruptures on the WFZ need to be investigated.
Liu, D W; Westerfield, M
1988-01-01
1. The activity of the two classes of motoneurones, primary and secondary, which innervate myotomal muscle fibres in the zebra fish, was monitored with electromyographic and intracellular techniques. 2. Simultaneous EMG and intracellular recordings from muscle fibres showed that the activity of the two motor systems and of individual primary motoneurones can be distinguished by recording EMG spikes during swimming. 3. Measurements of EMG spikes demonstrated that primary and secondary motoneurones are co-ordinately activated over a wide range of conditions during normal swimming. 4. During swimming the primary motoneurones within a given segment are usually co-activated although they sometimes fire independently. 5. When different primary motoneurones within a given segment are co-activated, they fire nearly synchronously. 6. We conclude that the primary motoneurones are used principally, although not exclusively, during fast swimming, struggling and the startle response, whereas secondary motoneurones function primarily during slower swimming. PMID:3253426
NASA Astrophysics Data System (ADS)
Finchenko, V. S.; Ivankov, A. A.; Shmatov, S. I.; Mordvinkin, A. S.
2015-12-01
The article presents the initial data for the ExoMars landing module aerothermodynamic calculations, used calculation methods, the calculation results of aerodynamic characteristics of the landing module shape and structural parameters of thermal protection selected during the conceptual design phase. Also, the test results of the destruction of the thermal protection material and comparison of the basic characteristics of the landing module with a front shield in the form of a cone and a spherical segment are presented.
The large-area hybrid-optics RICH detector for the CLAS12 spectrometer
NASA Astrophysics Data System (ADS)
Mirazita, M.; Angelini, G.; Balossino, I.; Barion, L.; Bailey, K.; Benmokhtar, F.; Brooks, W.; Cisbani, E.; Contalbrigo, M.; Cuevas, C.; Hafidi, K.; Kim, A.; Kubarovsky, V.; Lucherini, V.; Malaguti, R.; Montgomery, R.; Movsisyan, A.; Musico, P.; O'Connor, T.; Orecchini, D.; Pappalardo, L.; Perrino, R.; Pisano, S.; Raydo, B.; Rossi, P.; Squerzanti, S.; Tomassini, S.; Turisini, M.
2017-12-01
A large area imaging Cherenkov detector is under construction to provide hadron identification in the momentum range between 3 and 8 GeV/c for the CLAS12 exeperiment at the new 12 GeV electron beam of the Jefferson Laboratory (JLab). The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors and highly-segmented photon detectors. Cherenkov photons will be imaged either directly (for forward tracks) or after two mirror reflections (large angle tracks). The status of the detector construction is here reported.
Using multifield measurements to eliminate alignment degeneracies in the JWST testbed telescope
NASA Astrophysics Data System (ADS)
Sabatke, Erin; Acton, Scott; Schwenker, John; Towell, Tim; Carey, Larkin; Shields, Duncan; Contos, Adam; Leviton, Doug
2007-09-01
The primary mirror of the James Webb Space Telescope (JWST) consists of 18 segments and is 6.6 meters in diameter. A sequence of commissioning steps is carried out at a single field point to align the segments. At that single field point, though, the segmented primary mirror can compensate for aberrations caused by misalignments of the remaining mirrors. The misalignments can be detected in the wavefronts of off-axis field points. The Multifield (MF) step in the commissioning process surveys five field points and uses a simple matrix multiplication to calculate corrected positions for the secondary and primary mirrors. A demonstration of the Multifield process was carried out on the JWST Testbed Telescope (TBT). The results show that the Multifield algorithm is capable of reducing the field dependency of the TBT to about 20 nm RMS, relative to the TBT design nominal field dependency.
Alhashash, Mohamed; Shousha, Mootaz; Boehm, Heinrich
2018-05-01
A retrospective study of 70 patients undergoing surgical treatment for adjacent segment disease (ASD) after anterior cervical decompression and fusion (ACDF). To analyze the risk factors for the development of ASD in patients who underwent ACDF. ACDF has provided a high rate of clinical success for the cervical degenerative disc disease; nevertheless, adjacent segment degeneration has been reported as a complication at the adjacent level secondary to the rigid fixation. Between January 2005 and December 2012, 70 consecutive patients underwent surgery for ASD after ACDF in our institution. In all patients thorough clinical and radiological examination was performed preoperatively, postoperatively, and at the final follow-up. The clinical data included the Neck Disability Index (NDI) and the Visual Analogue Scale (VAS). The radiological evaluation included x-rays and magnetic resonance imaging (MRI) for all patients. The duration of follow up after the adjacent segment operation ranged from 3 to 10 years. Surgery for ASD was performed after a mean period of 32 months from the primary ACDF. ASD occurred after single level ACDF in 54% of cases, most commonly after C5/6 fusion (28%). Risk factors for ASD were found to be preexisting radiological signs of degeneration at the primary surgery (74%) and bad sagittal profile after the primary ACDF (90%). ASD occurred predominantly in the middle cervical region (C4-6); especially in patients with preexisting evidence of radiological degeneration in the adjacent segment at the time of primary cervical fusion, notably when this surgery failed to restore or maintain the cervical lordosis. 4.
Robustness of Thirty Meter Telescope primary mirror control
NASA Astrophysics Data System (ADS)
Macmynowski, Douglas G.; Thompson, Peter M.; Shelton, Chris; Roberts, Lewis C., Jr.
2010-07-01
The primary mirror control system for the Thirty Meter Telescope (TMT) maintains the alignment of the 492 segments in the presence of both quasi-static (gravity and thermal) and dynamic disturbances due to unsteady wind loads. The latter results in a desired control bandwidth of 1Hz at high spatial frequencies. The achievable bandwidth is limited by robustness to (i) uncertain telescope structural dynamics (control-structure interaction) and (ii) small perturbations in the ill-conditioned influence matrix that relates segment edge sensor response to actuator commands. Both of these effects are considered herein using models of TMT. The former is explored through multivariable sensitivity analysis on a reduced-order Zernike-basis representation of the structural dynamics. The interaction matrix ("A-matrix") uncertainty has been analyzed theoretically elsewhere, and is examined here for realistic amplitude perturbations due to segment and sensor installation errors, and gravity and thermal induced segment motion. The primary influence of A-matrix uncertainty is on the control of "focusmode"; this is the least observable mode, measurable only through the edge-sensor (gap-dependent) sensitivity to the dihedral angle between segments. Accurately estimating focus-mode will require updating the A-matrix as a function of the measured gap. A-matrix uncertainty also results in a higher gain-margin requirement for focus-mode, and hence the A-matrix and CSI robustness need to be understood simultaneously. Based on the robustness analysis, the desired 1 Hz bandwidth is achievable in the presence of uncertainty for all except the lowest spatial-frequency response patterns of the primary mirror.
ARV Re-Entry Module Aerodynmics And Aerothermodynamics
NASA Astrophysics Data System (ADS)
Scheer, Heloise; Tran, Philippe; Berthe, Philippe
2011-05-01
Astrium-ST is the prime contractor of ARV phase A and is especially in charge of designing the Reentry Module (RM). The RM aeroshape has been defined following a trade-off. High level system requirements were derived with particular attention paid on minimum lift-over-drag ratio, trim incidence, centre-of-gravity lateral off-set and box size, volumetric efficiency, attitude at parachute deployment, flight heritage and aeroheating. Since moderate cross-range and thus L/D ratio were required, the aeroshape trade-off has been performed among blunt capsule candidates. Two front- shield families were considered: spherical (Apollo/ARD/Soyuz type) and sphero-conical (CTV type) segment front-shield. The rear-cone angle was set to 20° for internal pressurized volume and accommodation purposes. Figures of merit were assessed and a spherical front- shield of ARD type with a 20° rear-cone section was selected and proposed for further investigations. Maximum benefits will be taken from ARD flight heritage. CFD and WTT campaigns plans will be presented including preliminary results.
3-D World Modeling For An Autonomous Robot
NASA Astrophysics Data System (ADS)
Goldstein, M.; Pin, F. G.; Weisbin, C. R.
1987-01-01
This paper presents a methodology for a concise representation of the 3-D world model for a mobile robot, using range data. The process starts with the segmentation of the scene into "objects" that are given a unique label, based on principles of range continuity. Then the external surface of each object is partitioned into homogeneous surface patches. Contours of surface patches in 3-D space are identified by estimating the normal and curvature associated with each pixel. The resulting surface patches are then classified as planar, convex or concave. Since the world model uses a volumetric representation for the 3-D environment, planar surfaces are represented by thin volumetric polyhedra. Spherical and cylindrical surfaces are extracted and represented by appropriate volumetric primitives. All other surfaces are represented using the boolean union of spherical volumes (as described in a separate paper by the same authors). The result is a general, concise representation of the external 3-D world, which allows for efficient and robust 3-D object recognition.
Shock waves from non-spherically collapsing cavitation bubbles
NASA Astrophysics Data System (ADS)
Supponen, Outi; Obreschkow, Danail; Farhat, Mohamed
2017-11-01
Combining simultaneous high-speed imaging and hydrophone measurements, we uncover details of the multiple shock wave emission from laser-induced cavitation bubbles collapsing in a non-spherical way. For strongly deformed bubbles collapsing near a free surface, we identify the distinct shock waves caused by the jet impact onto the opposite bubble wall and by the individual collapses of the remaining bubble segments. The energy carried by each of these shocks depends on the level of bubble deformation, quantified by the anisotropy parameter ζ, the dimensionless equivalent of the Kelvin impulse. For jetting bubbles, at ζ < 0.01 , the jet impact hammer pressure is found to be the most energetic shock. Through statistical analysis of the experimental data and theoretical derivations, and by comparing bubbles deformed by different sources (variable gravity achieved on parabolic flights, and neighboring free and rigid surfaces), we find that the shock peak pressure may be approximated as the jet impact-induced water hammer as ph = 0.45 (ρc2 Δp) 1 / 2ζ-1 .
Establishment of segment polarity in the ectoderm of the leech Helobdella
NASA Technical Reports Server (NTRS)
Seaver, E. C.; Shankland, M.
2001-01-01
The segmented ectoderm and mesoderm of the leech arise via a stereotyped cell lineage from embryonic stem cells called teloblasts. Each teloblast gives rise to a column of primary blast cell daughters, and the blast cells generate descendant clones that serve as the segmental repeats of their particular teloblast lineage. We have examined the mechanism by which the leech primary blast cell clones acquire segment polarity - i.e. a fixed sequence of positional values ordered along the anteroposterior axis of the segmental repeat. In the O and P teloblast lineages, the earliest divisions of the primary blast cell segregate anterior and posterior cell fates along the anteroposterior axis. Using a laser microbeam, we ablated single cells from both o and p blast cell clones at stages when the clone was two to four cells in length. The developmental fate of the remaining cells was characterized with rhodamine-dextran lineage tracer. Twelve different progeny cells were ablated, and in every case the ablation eliminated the normal descendants of the ablated cell while having little or no detectable effect on the developmental fate of the remaining cells. This included experiments in which we specifically ablated those blast cell progeny that are known to express the engrailed gene, or their lineal precursors. These findings confirm and extend a previous study by showing that the establishment of segment polarity in the leech ectoderm is largely independent of cell interactions conveyed along the anteroposterior axis. Both intercellular signaling and engrailed expression play an important role in the segment polarity specification of the Drosophila embryo, and our findings suggest that there may be little or no conservation of this developmental mechanism between those two organisms.
Shahedi, Maysam; Halicek, Martin; Guo, Rongrong; Zhang, Guoyi; Schuster, David M; Fei, Baowei
2018-06-01
Prostate segmentation in computed tomography (CT) images is useful for treatment planning and procedure guidance such as external beam radiotherapy and brachytherapy. However, because of the low, soft tissue contrast of CT images, manual segmentation of the prostate is a time-consuming task with high interobserver variation. In this study, we proposed a semiautomated, three-dimensional (3D) segmentation for prostate CT images using shape and texture analysis and we evaluated the method against manual reference segmentations. The prostate gland usually has a globular shape with a smoothly curved surface, and its shape could be accurately modeled or reconstructed having a limited number of well-distributed surface points. In a training dataset, using the prostate gland centroid point as the origin of a coordination system, we defined an intersubject correspondence between the prostate surface points based on the spherical coordinates. We applied this correspondence to generate a point distribution model for prostate shape using principal component analysis and to study the local texture difference between prostate and nonprostate tissue close to the different prostate surface subregions. We used the learned shape and texture characteristics of the prostate in CT images and then combined them with user inputs to segment a new image. We trained our segmentation algorithm using 23 CT images and tested the algorithm on two sets of 10 nonbrachytherapy and 37 postlow dose rate brachytherapy CT images. We used a set of error metrics to evaluate the segmentation results using two experts' manual reference segmentations. For both nonbrachytherapy and post-brachytherapy image sets, the average measured Dice similarity coefficient (DSC) was 88% and the average mean absolute distance (MAD) was 1.9 mm. The average measured differences between the two experts on both datasets were 92% (DSC) and 1.1 mm (MAD). The proposed, semiautomatic segmentation algorithm showed a fast, robust, and accurate performance for 3D prostate segmentation of CT images, specifically when no previous, intrapatient information, that is, previously segmented images, was available. The accuracy of the algorithm is comparable to the best performance results reported in the literature and approaches the interexpert variability observed in manual segmentation. © 2018 American Association of Physicists in Medicine.
LDR structural experiment definition
NASA Technical Reports Server (NTRS)
Russell, R. A.
1988-01-01
A system study to develop the definition of a structural flight experiment for a large precision segmented reflector on the Space Station was accomplished by the Boeing Aerospace Company for NASA's Langley Research Center. The objective of the study was to use a Large Deployable Reflector (LDR) baseline configuration as the basis for focusing an experiment definition, so that the resulting accommodation requirements and interface constraints could be used as part of the mission requirements data base for Space Station. The primary objectives of the first experiment are to construct the primary mirror support truss and to determine its structural and thermal characteristics. Addition of an optical bench, thermal shield and primary mirror segments, and alignment of the optical components, would occur on a second experiment. The structure would then be moved to the payload point system for pointing, optical control, and scientific optical measurement for a third experiment. Experiment 1 will deploy the primary support truss while it is attached to the instrument module structure. The ability to adjust the mirror attachment points and to attach several dummy primary mirror segments with a robotic system will also be demonstrated. Experiment 2 will be achieved by adding new components and equipment to experiment one. Experiment 3 will demonstrate advanced control strategies, active adjustment of the primary mirror alignment, and technologies associated with optical sensing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lapuyade-Lahorgue, J; Ruan, S; Li, H
Purpose: Multi-tracer PET imaging is getting more attention in radiotherapy by providing additional tumor volume information such as glucose and oxygenation. However, automatic PET-based tumor segmentation is still a very challenging problem. We propose a statistical fusion approach to joint segment the sub-area of tumors from the two tracers FDG and FMISO PET images. Methods: Non-standardized Gamma distributions are convenient to model intensity distributions in PET. As a serious correlation exists in multi-tracer PET images, we proposed a new fusion method based on copula which is capable to represent dependency between different tracers. The Hidden Markov Field (HMF) model ismore » used to represent spatial relationship between PET image voxels and statistical dynamics of intensities for each modality. Real PET images of five patients with FDG and FMISO are used to evaluate quantitatively and qualitatively our method. A comparison between individual and multi-tracer segmentations was conducted to show advantages of the proposed fusion method. Results: The segmentation results show that fusion with Gaussian copula can receive high Dice coefficient of 0.84 compared to that of 0.54 and 0.3 of monomodal segmentation results based on individual segmentation of FDG and FMISO PET images. In addition, high correlation coefficients (0.75 to 0.91) for the Gaussian copula for all five testing patients indicates the dependency between tumor regions in the multi-tracer PET images. Conclusion: This study shows that using multi-tracer PET imaging can efficiently improve the segmentation of tumor region where hypoxia and glucidic consumption are present at the same time. Introduction of copulas for modeling the dependency between two tracers can simultaneously take into account information from both tracers and deal with two pathological phenomena. Future work will be to consider other families of copula such as spherical and archimedian copulas, and to eliminate partial volume effect by considering dependency between neighboring voxels.« less
Li, Qiang; Tong, Zichuan; Wang, Lefeng; Zhang, Jianjun; Ge, Yonggui; Wang, Hongshi; Li, Weiming; Xu, Li; Ni, Zhuhua
2013-01-01
Introduction With long-term follow-up, whether biodegradable polymer drug-eluting stents (DES) is efficient and safe in primary percutaneous coronary intervention (PCI) remains a controversial issue. This study aims to assess the long-term efficacy and safety of DES in PCI for ST-segment elevation myocardial infarction (STEMI). Material and methods A prospective, randomized single-blind study with 3-year follow-up was performed to compare biodegradable polymer DES with durable polymer DES in 332 STEMI patients treated with primary PCI. The primary end point was major adverse cardiac events (MACE) at 3 years after the procedure, defined as the composite of cardiac death, recurrent infarction, and target vessel revascularization. The secondary end points included in-segment late luminal loss (LLL) and binary restenosis at 9 months and cumulative stent thrombosis (ST) event rates up to 3 years. Results The rate of the primary end points and the secondary end points including major adverse cardiac events, in-segment late luminal loss, binary restenosis, and cumulative thrombotic event rates were comparable between biodegradable polymer DES and durable polymer DES in these 332 STEMI patients treated with primary PCI at 3 years. Conclusions Biodegradable polymer DES has similar efficacy and safety profiles at 3 years compared with durable polymer DES in STEMI patients treated with primary PCI. PMID:24482648
A self-similar magnetohydrodynamic model for ball lightnings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsui, K. H.
2006-07-15
Ball lightning is modeled by magnetohydrodynamic (MHD) equations in two-dimensional spherical geometry with azimuthal symmetry. Dynamic evolutions in the radial direction are described by the self-similar evolution function y(t). The plasma pressure, mass density, and magnetic fields are solved in terms of the radial label {eta}. This model gives spherical MHD plasmoids with axisymmetric force-free magnetic field, and spherically symmetric plasma pressure and mass density, which self-consistently determine the polytropic index {gamma}. The spatially oscillating nature of the radial and meridional field structures indicate embedded regions of closed field lines. These regions are named secondary plasmoids, whereas the overall self-similarmore » spherical structure is named the primary plasmoid. According to this model, the time evolution function allows the primary plasmoid expand outward in two modes. The corresponding ejection of the embedded secondary plasmoids results in ball lightning offering an answer as how they come into being. The first is an accelerated expanding mode. This mode appears to fit plasmoids ejected from thundercloud tops with acceleration to ionosphere seen in high altitude atmospheric observations of sprites and blue jets. It also appears to account for midair high-speed ball lightning overtaking airplanes, and ground level high-speed energetic ball lightning. The second is a decelerated expanding mode, and it appears to be compatible to slowly moving ball lightning seen near ground level. The inverse of this second mode corresponds to an accelerated inward collapse, which could bring ball lightning to an end sometimes with a cracking sound.« less
The GTC: a convenient test bench for ELT demonstrations
NASA Astrophysics Data System (ADS)
Rodriguez Espinosa, Jose M.; Hammersley, Peter L.; Martinez-Roger, Carlos
2004-07-01
The Gran Telescopio Canarias (GTC) is, being assembled at the Observatorio del Roque de los Muchachos (ORM) in the island of La Palma. First light is expected for early 2005 with the first science observations late in 2005. The GTC, being a segmented primary mirror telescope, could be employed for testing several technological aspects relevant to the future generation of Extremely Large Telescopes (ELT). In the short term, the mass production of aespheric mirror segments can be examined in detail and improvements made along the way, or planned for the future. Indeed the GTC segments are now entering into a chain production scheme. Later on, different strategies for the control aspects of the primary mirror can be explored to optimize the optical performance of segmented telescopes. Moreover, the entire GTC active optics can offer a learning tool for testing various strategies and their application to ELTs.
Diffraction peak profiles of surface relaxed spherical nanocrystals
NASA Astrophysics Data System (ADS)
Perez-Demydenko, C.; Scardi, P.
2017-09-01
A model is proposed for surface relaxation of spherical nanocrystals. Besides reproducing the primary effect of changing the average unit cell parameter, the model accounts for the inhomogeneous atomic displacement caused by surface relaxation and its effect on the diffraction line profiles. Based on three parameters with clear physical meanings - extension of the sub-coordination effect, maximum radial displacement due to sub-coordination, and effective hydrostatic pressure - the model also considers elastic anisotropy and provides parametric expressions of the diffraction line profiles directly applicable in data analysis. The model was tested on spherical nanocrystals of several fcc metals, matching atomic positions with those provided by Molecular Dynamics (MD) simulations based on embedded atom potentials. Agreement was also verified between powder diffraction patterns generated by the Debye scattering equation, using atomic positions from MD and the proposed model.
Wavefront Compensation Segmented Mirror Sensing and Control
NASA Technical Reports Server (NTRS)
Redding, David C.; Lou, John Z.; Kissil, Andrew; Bradford, Charles M.; Woody, David; Padin, Stephen
2012-01-01
The primary mirror of very large submillimeter-wave telescopes will necessarily be segmented into many separate mirror panels. These panels must be continuously co-phased to keep the telescope wavefront error less than a small fraction of a wavelength, to ten microns RMS (root mean square) or less. This performance must be maintained continuously across the full aperture of the telescope, in all pointing conditions, and in a variable thermal environment. A wavefront compensation segmented mirror sensing and control system, consisting of optical edge sensors, Wavefront Compensation Estimator/Controller Soft ware, and segment position actuators is proposed. Optical edge sensors are placed two per each segment-to-segment edge to continuously measure changes in segment state. Segment position actuators (three per segment) are used to move the panels. A computer control system uses the edge sensor measurements to estimate the state of all of the segments and to predict the wavefront error; segment actuator commands are computed that minimize the wavefront error. Translational or rotational motions of one segment relative to the other cause lateral displacement of the light beam, which is measured by the imaging sensor. For high accuracy, the collimator uses a shaped mask, such as one or more slits, so that the light beam forms a pattern on the sensor that permits sensing accuracy of better than 0.1 micron in two axes: in the z or local surface normal direction, and in the y direction parallel to the mirror surface and perpendicular to the beam direction. Using a co-aligned pair of sensors, with the location of the detector and collimated light source interchanged, four degrees of freedom can be sensed: transverse x and y displacements, as well as two bending angles (pitch and yaw). In this approach, each optical edge sensor head has a collimator and an imager, placing one sensor head on each side of a segment gap, with two parallel light beams crossing the gap. Two sets of optical edge sensors are used per segment-to-segment edge, separated by a finite distance along the segment edge, for four optical heads, each with an imager and a collimator. By orienting the beam direction of one edge sensor pair to be +45 away from the segment edge direction, and the other sensor pair to be oriented -45 away from the segment edge direction, all six degrees of freedom of relative motion between the segments can be measured with some redundancy. The software resides in a computer that receives each of the optical edge sensor signals, as well as telescope pointing commands. It feeds back the edge sensor signals to keep the primary mirror figure within specification. It uses a feed-forward control to compensate for global effects such as decollimation of the primary and secondary mirrors due to gravity sag as the telescope pointing changes to track science objects. Three segment position actuators will be provided per segment to enable controlled motions in the piston, tip, and tilt degrees of freedom. These actuators are driven by the software, providing the optical changes needed to keep the telescope phased.
Characteristic investigation of Golay9 multiple mirror telescope with a spherical primary mirror
NASA Astrophysics Data System (ADS)
Wu, Feng; Wu, Quanying; Zhu, Xifang; Xiang, Ruxi; Qian, Lin
2017-10-01
The sparse aperture provides a novel solution to the manufacturing difficulties of modern super large telescopes. Golay configurations are optimal in the sparse aperture family. Characteristics of the Golay9 multiple mirror telescope having a spherical primary mirror are investigated. The arrangement of the nine sub-mirrors is discussed after the planar Golay9 configuration is analyzed. The characteristics of the entrance pupil are derived by analyzing the sub-aperture shapes with different relative apertures and sub-mirror sizes. Formulas about the fill factor and the overlay factor are deduced. Their maximal values are presented based on the derived tangency condition. Formulas for the point spread function (PSF) and the modulation transfer function (MTF) of the Golay9 MMT are also deduced. Two Golay9 MMT have been developed by Zemax simulation. Their PSF, MTF, fill factors, and overlay factors prove that our theoretical results are consistent with the practical simulation ones.
NASA Technical Reports Server (NTRS)
Santoro, R. T.; Claiborne, H. C.; Alsmiller, R. G., Jr.
1972-01-01
Calculations have been made using the nucleon-meson transport code NMTC to estimate the absorbed dose and dose equivalent distributions in astronauts inside space vehicles bombarded by solar flare and Van Allen protons. A spherical shell shield of specific radius and thickness with a 30-cm-diam. tissue ball at the geometric center was used to simulate the spacecraft-astronaut configuration. The absorbed dose and the dose equivalent from primary protons, secondary protons, heavy nuclei, charged pions, muons, photons, and positrons and electrons are given as a function of depth in the tissue phantom. Results are given for solar flare protons with a characteristic rigidity of 100 MV and for Van Allen protons in a 240-nautical-mile circular orbit at 30 degree inclination angle incident on both 20-g/sq cm-thick aluminum and polyethylene spherical shell shields.
Wind Evaluation Breadboard electronics and software
NASA Astrophysics Data System (ADS)
Núñez, Miguel; Reyes, Marcos; Viera, Teodora; Zuluaga, Pablo
2008-07-01
WEB, the Wind Evaluation Breadboard, is an Extremely Large Telescope Primary Mirror simulator, developed with the aim of quantifying the ability of a segmented primary mirror to cope with wind disturbances. This instrument supported by the European Community (Framework Programme 6, ELT Design Study), is developed by ESO, IAC, MEDIA-ALTRAN, JUPASA and FOGALE. The WEB is a bench of about 20 tons and 7 meter diameter emulating a segmented primary mirror and its cell, with 7 hexagonal segments simulators, including electromechanical support systems. In this paper we present the WEB central control electronics and the software development which has to interface with: position actuators, auxiliary slave actuators, edge sensors, azimuth ring, elevation actuator, meteorological station and air balloons enclosure. The set of subsystems to control is a reduced version of a real telescope segmented primary mirror control system with high real time performance but emphasizing on development time efficiency and flexibility, because WEB is a test bench. The paper includes a detailed description of hardware and software, paying special attention to real time performance. The Hardware is composed of three computers and the Software architecture has been divided in three intercommunicated applications and they have been implemented using Labview over Windows XP and Pharlap ETS real time operating system. The edge sensors and position actuators close loop has a sampling and commanding frequency of 1KHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rueegsegger, Michael B.; Bach Cuadra, Meritxell; Pica, Alessia
Purpose: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Methods and Materials: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3Dmore » statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Results: Cross-validation revealed a dice similarity of 95% {+-} 2% for the sclera and cornea and 91% {+-} 2% for the lens. Overall, mean segmentation error was found to be 0.3 {+-} 0.1 mm. Average segmentation time was 14 {+-} 2 s on a standard personal computer. Conclusions: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.« less
Implementation of a Wavefront-Sensing Algorithm
NASA Technical Reports Server (NTRS)
Smith, Jeffrey S.; Dean, Bruce; Aronstein, David
2013-01-01
A computer program has been written as a unique implementation of an image-based wavefront-sensing algorithm reported in "Iterative-Transform Phase Retrieval Using Adaptive Diversity" (GSC-14879-1), NASA Tech Briefs, Vol. 31, No. 4 (April 2007), page 32. This software was originally intended for application to the James Webb Space Telescope, but is also applicable to other segmented-mirror telescopes. The software is capable of determining optical-wavefront information using, as input, a variable number of irradiance measurements collected in defocus planes about the best focal position. The software also uses input of the geometrical definition of the telescope exit pupil (otherwise denoted the pupil mask) to identify the locations of the segments of the primary telescope mirror. From the irradiance data and mask information, the software calculates an estimate of the optical wavefront (a measure of performance) of the telescope generally and across each primary mirror segment specifically. The software is capable of generating irradiance data, wavefront estimates, and basis functions for the full telescope and for each primary-mirror segment. Optionally, each of these pieces of information can be measured or computed outside of the software and incorporated during execution of the software.
[Gastrointestinal stromal tumor with primary hepatic unique location--clinical case].
Alecu, L; Tulin, A; Ursut, Beatrice; Ursut, B; Oproiu, Al; Obrocea, F; Ionescu, M
2011-01-01
The gastrointestinal stromal tumors are mesenchymal tumors whose primary extradigestive location is very rare (less than 10% primary liver localization). We present a clinical case of primary hepatic location of GIST in a 28 year-old patient. The discovery of this tumor is a chance, the patient presenting for non-specific dyspeptic syndrome and epigastralgia. During the presentation an abdominal ultrasound is performed which identifies an whell-delineated hepatic mass - 5/4 cm. Clinical and paraclinical investigations (CT, EDS, EDI, examination of the intestinal lumen with the videocapsula), confirm the diagnosis of unique hepatic mass of segments III-IV. The diagnosis is confirmed intraoperatory and we perform an atypical liver resection of segments III-IV (with 1 cm safety-margin). The histopatologic exam: GIST.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buseck, Peter
2016-03-01
During two Intensive Operational Periods (IOP), we collected samples at 3-hour intervals for transmission electron microscopy analysis. The resulting transmission electron microscopy images and compositions were analyzed for the samples of interest. Further analysis will be done especially for the plume of interest. We found solid spherical organic particles from rebounded samples collected with Professor Scot Martin’s group (Harvard University). Approximately 30% of the rebounded particles at 95% relative humidity were spherical organic particles. Their sources and formation process are not known, but such spherical particles could be solid and will have heterogeneous chemical reactions. We observed many organic particlesmore » that are internally mixed with inorganic elements such as potassium and nitrogen. They are either homogeneously mixed or have inorganic cores with organic aerosol coatings. Samples collected from the Manaus, Brazil, pollution plume included many nano-size soot particles mixed with organic material and sulfate. Aerosol particles from clean periods included organic aerosol particles, sulfate, sea salt, dust, and primary biogenic aerosol particles. There was more dust, primary biogenic aerosol, and tar balls in samples taken during IOP1 than those taken during IOP2. Many dust particles were found between March 2 and 3.« less
Cesic: manufacturing study for next generation telescopes
NASA Astrophysics Data System (ADS)
Kroedel, M.; Lichtscheindl, J.; Mair, Hp.
2005-08-01
Under ESO - European Southern Observatory - contract ECM has performed a feasibility study for the manufacturing of Cesic primary and secondary mirror segments for the OWL-Telescope. The main issues of this study were to demonstrate the feasibility of the serial production (~ 2550 segments) of Cesic mirror segments under a certain schedule and cost optimisation aspect for the segments. Part of this study was also a pre-design of a manufacturing facility for this big amount of mirror segments. This study is limited only up to the manufacturing of a polishable surface, the feasibility of the polishing capability is not part of this study.
Nguyen, Thanh; Bui, Vy; Lam, Van; Raub, Christopher B; Chang, Lin-Ching; Nehmetallah, George
2017-06-26
We propose a fully automatic technique to obtain aberration free quantitative phase imaging in digital holographic microscopy (DHM) based on deep learning. The traditional DHM solves the phase aberration compensation problem by manually detecting the background for quantitative measurement. This would be a drawback in real time implementation and for dynamic processes such as cell migration phenomena. A recent automatic aberration compensation approach using principle component analysis (PCA) in DHM avoids human intervention regardless of the cells' motion. However, it corrects spherical/elliptical aberration only and disregards the higher order aberrations. Traditional image segmentation techniques can be employed to spatially detect cell locations. Ideally, automatic image segmentation techniques make real time measurement possible. However, existing automatic unsupervised segmentation techniques have poor performance when applied to DHM phase images because of aberrations and speckle noise. In this paper, we propose a novel method that combines a supervised deep learning technique with convolutional neural network (CNN) and Zernike polynomial fitting (ZPF). The deep learning CNN is implemented to perform automatic background region detection that allows for ZPF to compute the self-conjugated phase to compensate for most aberrations.
Alignment test results of the JWST Pathfinder Telescope mirrors in the cryogenic environment
NASA Astrophysics Data System (ADS)
Whitman, Tony L.; Wells, Conrad; Hadaway, James B.; Knight, J. Scott; Lunt, Sharon
2016-07-01
After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASA's Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the Science Instrument (SI) detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.
Traumatic laryngotracheal stenosis--an alternative surgical technique.
Syal, Rajan; Tyagi, Isha; Goyal, Amit
2006-02-01
Reconstruction of combined laryngotracheal stenosis requires complex techniques including resection and incorporation of grafts and stents that can be performed as single or multistaged procedure. A complicated case of traumatic laryngotracheal stenosis was managed by us, surgical technique is discussed. A 16-year-old male presented with Stage-3 laryngotracheal stenosis of grade-3 to 4 (>70% of the complete obstruction of tracheal lumen) of 5 cm segment of the larynx and trachea. Restoration of the critical functions of respiration and phonation was achieved in this patient by resection anastomosis of the trachea and with subglottic remodeling. Resection of 5 cm long segment of trachea and primary anastomosis in this case would have created tension at the site of anastomosis. So we did tracheal resection of 3 cm segment of trachea along with subglottic remodeling instead of removing the 5 cm segment of stenosed laryngotracheal region and doing thyrotracheal anastomosis. In complicated long segment, laryngotracheal stenosis, tracheal resection and subglottic remodeling with primary anastomosis can be an alternative approach. Fibrin glue can be used to support free bone/cartilage grafts in laryngotracheal reconstructions.
Wear particles of single-crystal silicon carbide in vacuum
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Buckley, D. H.
1980-01-01
Sliding friction experiments, conducted in vacuum with silicon carbide /000/ surface in contact with iron based binary alloys are described. Multiangular and spherical wear particles of silicon carbide are observed as a result of multipass sliding. The multiangular particles are produced by primary and secondary cracking of cleavage planes /000/, /10(-1)0/, and /11(-2)0/ under the Hertzian stress field or local inelastic deformation zone. The spherical particles may be produced by two mechanisms: (1) a penny shaped fracture along the circular stress trajectories under the local inelastic deformation zone, and (2) attrition of wear particles.
Combined approach to the Hubble Space Telescope wave-front distortion analysis
NASA Astrophysics Data System (ADS)
Roddier, Claude; Roddier, Francois
1993-06-01
Stellar images taken by the HST at various focus positions have been analyzed to estimate wave-front distortion. Rather than using a single algorithm, we found that better results were obtained by combining the advantages of various algorithms. For the planetary camera, the most accurate algorithms consistently gave a spherical aberration of -0.290-micron rms with a maximum deviation of 0.005 micron. Evidence was found that the spherical aberration is essentially produced by the primary mirror. The illumination in the telescope pupil plane was reconstructed and evidence was found for a slight camera misalignment.
Phase Behavior of Binary Blends of AB+AC Block Copolymers with compatible B and C blocks
NASA Astrophysics Data System (ADS)
Pryamitsyn, Victor; Ganesan, Venkat
2012-02-01
Recently the experimental studies of phase behavior of binary blends of PS-b-P2VP and PS-b-PHS demonstrated an interesting effect: blends of symmetric PS-b-P2VP and shorter symmetric (PS-b-PHS) formed cylindrical HEX and spherical BCC phases, while each pure component formed lamellas. The miscibility of P2VP and PHS is caused by the hydrogen bonding between P2VP and PHS,which can be described as a negative Flory ?-parameter between P2VP and PHS. We developed a theory of the microphase segregation of AB+AC blends of diblock copolymers based on strong stretching theory. The main result of our theory is that in the copolymer brush-like layer formed by longer B chain and shorter C chains, the attraction between B and shorter C chains causes relative stretching of short C chains and compression of longer B chains. The latter manifests in an excessive bending force towards the grafting surface (BC|AA interface). Such bending force causes a transition from a symmetric lamella phase to a HEX cylinder or BCC spherical phases with the BC phase being a ``matrix'' component. In a blend of asymmetric BCC sphere forming copolymers (where B and C segments are the minor components), such bending force may unfold BCC spherical phase to a HEX cylinder phase, or even highly uneven lamella phases.
NASA Astrophysics Data System (ADS)
Egron, Sylvain; Soummer, Rémi; Lajoie, Charles-Philippe; Bonnefois, Aurélie; Long, Joseph; Michau, Vincent; Choquet, Elodie; Ferrari, Marc; Leboulleux, Lucie; Levecq, Olivier; Mazoyer, Johan; N'Diaye, Mamadou; Perrin, Marshall; Petrone, Peter; Pueyo, Laurent; Sivaramakrishnan, Anand
2017-09-01
The James Webb Space Telescope (JWST) Optical Simulation Testbed (JOST) is a tabletop experiment designed to study wavefront sensing and control for a segmented space telescope, such as JWST. With the JWST Science and Operations Center co-located at STScI, JOST was developed to provide both a platform for staff training and to test alternate wavefront sensing and control strategies for independent validation or future improvements beyond the baseline operations. The design of JOST reproduces the physics of JWST's three-mirror anastigmat (TMA) using three custom aspheric lenses. It provides similar quality image as JWST (80% Strehl ratio) over a field equivalent to a NIRCam module, but at 633 nm. An Iris AO segmented mirror stands for the segmented primary mirror of JWST. Actuators allow us to control (1) the 18 segments of the segmented mirror in piston, tip, tilt and (2) the second lens, which stands for the secondary mirror, in tip, tilt and x, y, z positions. We present the most recent experimental results for the segmented mirror alignment. Our implementation of the Wavefront Sensing (WFS) algorithms using phase diversity is tested on simulation and experimentally. The wavefront control (WFC) algorithms, which rely on a linear model for optical aberrations induced by misalignment of the secondary lens and the segmented mirror, are tested and validated both on simulations and experimentally. In this proceeding, we present the performance of the full active optic control loop in presence of perturbations on the segmented mirror, and we detail the quality of the alignment correction.
Air traffic management evaluation tool
NASA Technical Reports Server (NTRS)
Sridhar, Banavar (Inventor); Chatterji, Gano Broto (Inventor); Schipper, John F. (Inventor); Bilimoria, Karl D. (Inventor); Grabbe, Shon (Inventor); Sheth, Kapil S. (Inventor)
2012-01-01
Methods for evaluating and implementing air traffic management tools and approaches for managing and avoiding an air traffic incident before the incident occurs. A first system receives parameters for flight plan configurations (e.g., initial fuel carried, flight route, flight route segments followed, flight altitude for a given flight route segment, aircraft velocity for each flight route segment, flight route ascent rate, flight route descent route, flight departure site, flight departure time, flight arrival time, flight destination site and/or alternate flight destination site), flight plan schedule, expected weather along each flight route segment, aircraft specifics, airspace (altitude) bounds for each flight route segment, navigational aids available. The invention provides flight plan routing and direct routing or wind optimal routing, using great circle navigation and spherical Earth geometry. The invention provides for aircraft dynamics effects, such as wind effects at each altitude, altitude changes, airspeed changes and aircraft turns to provide predictions of aircraft trajectory (and, optionally, aircraft fuel use). A second system provides several aviation applications using the first system. Several classes of potential incidents are analyzed and averted, by appropriate change en route of one or more parameters in the flight plan configuration, as provided by a conflict detection and resolution module and/or traffic flow management modules. These applications include conflict detection and resolution, miles-in trail or minutes-in-trail aircraft separation, flight arrival management, flight re-routing, weather prediction and analysis and interpolation of weather variables based upon sparse measurements. The invention combines these features to provide an aircraft monitoring system and an aircraft user system that interact and negotiate changes with each other.
NASA Astrophysics Data System (ADS)
Li, Bing; Shi, Xuefa; Wang, Jixin; Yan, Quanshu; Liu, Chenguang; DY125-21 (Leg 3) Science Party; DY125-22 (Legs 2-5) Science Party; DY125-26 (Leg 3) Science Party
2018-05-01
Systematic hydrothermal exploration and multi-beam bathymetry mapping have been conducted along a 220-km-long section of the Southern Mid-Atlantic Ridge (SMAR) from 12°S (Bode Verde Fracture Zone) to 14°S (Cardno Fracture Zone), and previously reported deposits (Tao et al., 2011) are now being thoroughly investigated. Here, we present the characterization of three possible hydrothermal fields, a complete bathymetry data set of the ridge segment, gravity data, and the petrologic characteristics of collected rock samples. The magmatism characteristics, evolution of the ridge segment, and the local geological controls of the possible hydrothermal fields are then discussed. The studied segment can be divided into two segments by a Non-Transform Discontinuity (NTD). Our morphotectonic analysis shows significant along-axis heterogeneity in the surveyed segments: three distinctive cross-axis grabens were identified in the northern segment, and two were identified in the southern segment. Moreover, based on the gravity data (a relatively low spherical Bouguer anomaly) and petrologic data (low Mg# values and relatively low FeO and relatively high Al2O3 and CaO contents compared to nearby seafloor samples), a volcanic feature, the ZouYu seamount, on this segment is considered to be associated with strong magmatic activity, and the magmatic activity of the inside corner at the southern end of the segment has increased and decreased. The three possible hydrothermal fields occur in different local geological settings: a shallow magmatic seamount (ZouYu), an NTD (TaiJi), and an inside-corner high (CaiFan). These potential hydrothermal fields are significantly different from other fields in similar tectonic settings in terms of local geologic controls and products. The ZouYu field is primarily related to a newly formed cone, resulting in the production of sulfides, and differs from other fields on shallow magmatic seamounts. The TaiJi field is largely controlled by the tectonic evolution of the NTD and is based on mafic rocks. The inside corner containing the CaiFan field is a magmatic seamount rather than an Ocean Core Complex, making it strikingly different from other inside corner-related fields.
Resolving the Southern African Large Telescope's image quality problems
NASA Astrophysics Data System (ADS)
O'Donoghue, Darragh E.; Crause, Lisa A.; O'Connor, James; Strümpfer, Francois; Strydom, Ockert J.; Sass, Craig; Brink, Janus D.; Plessis, Charl du; Wiid, Eben; Love, Jonathan
2013-08-01
Images obtained with the Southern African Large Telescope (SALT) during its commissioning phase in 2006 showed degradation due to a large focus gradient, astigmatism, and higher order optical aberrations. An extensive forensic investigation exonerated the primary mirror and the science instruments before pointing to the mechanical interface between the telescope and the spherical aberration corrector, the complex optical subassembly which corrects the spherical aberration introduced by the 11-m primary mirror. Having diagnosed the problem, a detailed repair plan was formulated and implemented when the corrector was removed from the telescope in April 2009. The problematic interface was replaced, and the four aspheric mirrors were optically tested and re-aligned. Individual mirror surface figures were confirmed to meet specification, and a full system test after the re-alignment yielded a root mean square wavefront error of 0.15 waves. The corrector was reinstalled in August 2010 and aligned with respect to the payload and primary mirror. Subsequent on-sky tests revealed spurious signals being sent to the tracker by the auto-collimator, the instrument that maintains the alignment of the corrector with respect to the primary mirror. After rectifying this minor issue, the telescope yielded uniform 1.1 arcsec star images over the full 10-arcmin field of view.
Three-Dimensional Spherical Models of Convection in the Earth's Mantle.
Bercovici, D; Schubert, G; Glatzmaier, G A
1989-05-26
Three-dimensional, spherical models of mantle convection in the earth reveal that upwelling cylindrical plumes and downwelling planar sheets are the primary features of mantle circulation. Thus, subduction zones and descending sheetlike slabs in the mantle are fundamental characteristics of thermal convection in a spherical shell and are not merely the consequences of the rigidity of the slabs, which are cooler than the surrounding mantle. Cylindrical mantle plumes that cause hotspots such as Hawaii are probably the only form of active upwelling and are therefore not just secondary convective currents separate from the large-scale mantle circulation. Active sheetlike upwellings that could be associated with mid-ocean ridges did not develop in the model simulations, a result that is in agreement with evidence suggesting that ridges are passive phenomena resulting from the tearing of surface plates by the pull of descending slabs.
NASA Astrophysics Data System (ADS)
Eliçabe, Guillermo E.
2013-09-01
In this work, an exact scattering model for a system of clusters of spherical particles, based on the Rayleigh-Gans approximation, has been parameterized in such a way that it can be solved in inverse form using Thikhonov Regularization to obtain the morphological parameters of the clusters. That is to say, the average number of particles per cluster, the size of the primary spherical units that form the cluster, and the Discrete Distance Distribution Function from which the z-average square radius of gyration of the system of clusters is obtained. The methodology is validated through a series of simulated and experimental examples of x-ray and light scattering that show that the proposed methodology works satisfactorily in unideal situations such as: presence of error in the measurements, presence of error in the model, and several types of unideallities present in the experimental cases.
NASA Astrophysics Data System (ADS)
Kumagai, Toshiki; Hibino, Kenichi; Nagaike, Yasunari
2017-03-01
Internally scattered light in a Fizeau interferometer is generated from dust, defects, imperfect coating of the optical components, and multiple reflections inside the collimator lens. It produces additional noise fringes in the observed interference image and degrades the repeatability of the phase measurement. A method to reduce the phase measurement error is proposed, in which the test surface is mechanically translated between each phase measurement in addition to an ordinary phase shift of the reference surface. It is shown that a linear combination of several measured phases at different test surface positions can reduce the phase errors caused by the scattered light. The combination can also compensate for the nonuniformity of the phase shift that occurs in spherical tests. A symmetric sampling of the phase measurements can cancel the additional primary spherical aberrations that occur when the test surface is out of the null position of the confocal configuration.
Modeling of current characteristics of segmented Langmuir probe on DEMETER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imtiaz, Nadia; Marchand, Richard; Lebreton, Jean-Pierre
We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numericallymore » with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.« less
A Flux-Pinning Mechanism for Segment Assembly and Alignment
NASA Technical Reports Server (NTRS)
Gersh-Range, Jessica A.; Arnold, William R.; Peck, Mason A.; Stahl, H. Philip
2011-01-01
Currently, the most compelling astrophysics questions include how planets and the first stars formed and whether there are protostellar disks that contain large organic molecules. Although answering these questions requires space telescopes with apertures of at least 10 meters, such large primaries are challenging to construct by scaling up previous designs; the limited capacity of a launch vehicle bounds the maximum diameter of a monolithic primary, and beyond a certain size, deployable telescopes cannot fit in current launch vehicle fairings. One potential solution is connecting the primary mirror segments edgewise using flux-pinning mechanisms, which are analogous to non-contacting damped springs. In the baseline design, a flux-pinning mechanism consists of a magnet and a superconductor separated by a predetermined gap, with the damping adjusted by placing aluminum near the interface. Since flux pinning is possible only when the superconductor is cooled below a critical temperature, flux-pinning mechanisms are uniquely suited for cryogenic space telescopes. By placing these mechanisms along the edges of the mirror segments, a primary can be built up over time. Since flux pinning requires no mechanical deployments, the assembly process could be robotic or use some other non-contacting scheme. Advantages of this approach include scalability and passive stability.
Live-Cell Imaging of Phagosome Motility in Primary Mouse RPE Cells.
Hazim, Roni; Jiang, Mei; Esteve-Rudd, Julian; Diemer, Tanja; Lopes, Vanda S; Williams, David S
2016-01-01
The retinal pigment epithelium (RPE) is a post-mitotic epithelial monolayer situated between the light-sensitive photoreceptors and the choriocapillaris. Given its vital functions for healthy vision, the RPE is a primary target for insults that result in blinding diseases, including age-related macular degeneration (AMD). One such function is the phagocytosis and digestion of shed photoreceptor outer segments. In the present study, we examined the process of trafficking of outer segment disk membranes in live cultures of primary mouse RPE, using high speed spinning disk confocal microscopy. This approach has enabled us to track phagosomes, and determine parameters of their motility, which are important for their efficient degradation.
Hwang, Ji-Won; Yang, Jeong Hoon; Song, Young Bin; Park, Taek Kyu; Lee, Joo Myung; Kim, Ji-Hwan; Jang, Woo Jin; Choi, Seung-Hyuk; Hahn, Joo-Yong; Choi, Jin-Ho; Ahn, Joonghyun; Carriere, Keumhee; Lee, Sang Hoon; Gwon, Hyeon-Cheol
2018-02-22
We sought to determine the association of reciprocal change in the ST-segment with myocardial injury assessed by cardiac magnetic resonance (CMR) in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). We performed CMR imaging in 244 patients who underwent primary PCI for their first STEMI; CMR was performed a median 3 days after primary PCI. The first electrocardiogram was analyzed, and patients were stratified according to the presence of reciprocal change. The primary outcome was infarct size measured by CMR. Secondary outcomes were area at risk and myocardial salvage index. Patients with reciprocal change (n=133, 54.5%) had a lower incidence of anterior infarction (27.8% vs 71.2%, P < .001) and shorter symptom onset to balloon time (221.5±169.8 vs 289.7±337.3min, P=.042). Using a multiple linear regression model, we found that patients with reciprocal change had a larger area at risk (P=.002) and a greater myocardial salvage index (P=.04) than patients without reciprocal change. Consequently, myocardial infarct size was not significantly different between the 2 groups (P=.14). The rate of major adverse cardiovascular events, including all-cause death, myocardial infarction, and repeat coronary revascularization, was similar between the 2 groups after 2 years of follow-up (P=.92). Reciprocal ST-segment change was associated with larger extent of ischemic myocardium at risk and more myocardial salvage but not with final infarct size or adverse clinical outcomes in STEMI patients undergoing primary PCI. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Cophasing techniques for extremely large telescopes
NASA Astrophysics Data System (ADS)
Devaney, Nicholas; Schumacher, Achim
2004-07-01
The current designs of the majority of ELTs envisage that at least the primary mirror will be segmented. Phasing of the segments is therefore a major concern, and a lot of work is underway to determine the most suitable techniques. The techniques which have been developed are either wave optics generalizations of classical geometric optics tests (e.g. Shack-Hartmann and curvature sensing) or direct interferometric measurements. We present a review of the main techniques proposed for phasing and outline their relative merits. We consider problems which are specific to ELTs, e.g. vignetting of large parts of the primary mirror by the secondary mirror spiders, and the need to disentangle phase errors arising in different segmented mirrors. We present improvements in the Shack-Hartmann and curvature sensing techniques which allow greater precision and range. Finally, we describe a piston plate which simulates segment phasing errors and show the results of laboratory experiments carried out to verify the precision of the Shack-Hartmann technique.
Greco, Susan L; Wilson, Andrew M; Hanna, Steven R; Levy, Jonathan I
2007-11-15
Benefit-cost and regulatory impact analyses often use atmospheric dispersion models with coarse resolution to estimate the benefits of proposed mobile source emission control regulations. This approach may bias health estimates or miss important intra-urban variability for primary air pollutants. In this study, we estimate primary fine particulate matter (PM2.5) intake fractions (iF; the fraction of a pollutant emitted from a source that is inhaled by the population) for each of 23 398 road segments in the Boston Metro Core area to evaluate the potential for intra-urban variability in the emissions-to-exposure relationship. We estimate iFs using the CAL3QHCR line source model combined with residential populations within 5000 m of each road segment. The annual average values for the road segments range from 0.8 to 53 per million, with a mean of 12 per million. On average, 46% of the total exposure is realized within 200 m of the road segment, though this varies from 0 to 93% largely due to variable population patterns. Our findings indicate the likelihood of substantial intra-urban variability in mobile source primary PM2.5 iF that accounting for population movement with time, localized meteorological conditions, and street-canyon configurations would likely increase.
Calcium ion dependency of ethylene production in segments of primary roots of Zea mays
NASA Technical Reports Server (NTRS)
Hasenstein, K. H.; Evans, M. L.
1986-01-01
We investigated the effect of Ca2+ on ethylene production in 2-cm long apical segments from primary roots of corn (Zea mays L., B73 x Missouri 17) seedlings. The seedlings were raised under different conditions of Ca2+ availability. Low-Ca and high-Ca seedlings were raised by soaking the grains and watering the seedlings with distilled water or 10 mM CaCl2, respectively. Segments from high-Ca roots produced more than twice as much ethylene as segments from low-Ca roots. Indoleacetic acid (IAA; 1 micromole) enhanced ethylene production in segments from both low-Ca and high-Ca roots but auxin-induced promotion of ethylene production was consistently higher in segments from high-Ca roots. Addition of 1-aminocyclopropane-1-carboxylic acid (ACC) to root segments from low-Ca seedlings doubled total ethylene production and the rate of production remained fairly constant during a 24 h period of monitoring. In segments from high-Ca seedlings ACC also increased total ethylene production but most of the ethylene was produced within the first 6 h. The data suggest that Ca2+ enhances the conversion of ACC to ethylene. The terminal 2 mm of the root tip were found to be especially important to ethylene biosynthesis by apical segments and, experiments using 45Ca2+ as tracer indicated that the apical 2 mm of the root is the region of strongest Ca2+ accumulation. Other cations such as Mn2+, Mg2+, and K+ could largely substitute for Ca2+. The significance of these findings is discussed with respect to recent evidence for gravity-induced Ca2+ redistribution and its relationship to the establishment of asymmetric growth during gravitropic curvature.
Sakairi, Yuichi; Yoshino, Ichiro; Yoshida, Shigetoshi; Suzuki, Hidemi; Tagawa, Tetsuzo; Iwata, Takekazu; Mizobuchi, Teruaki
2014-05-01
Patterns of intrapulmonary metastasis, particularly metastasis outside tumor-bearing segments, were investigated in lung cancer patients to address the rationale for segmentectomy. In a consecutive series of patients who underwent resection of two or more pulmonary segments for primary lung cancer, intrapulmonary spread patterns, such as segmental/intersegmental node metastasis and pulmonary parenchymal metastasis, were pathologically examined. Eligible 244 lesions included 167 adenocarcinomas, 66 squamous cell carcinomas, and 11 large cell carcinomas. Pathologic stages included 0 to IA (n=111), IB (n=56), IIA (n=31), IIB (n=20), IIIA (n=23), and IIIB to IV (n=3); and N1 (n=26) and N2 (n=22). Intrapulmonary spread was observed in 24 cases (9.8%). Of these, metastasis outside tumor-bearing segments was only observed in 4 cases (1.6%), and such cancer spread was more frequently seen in cases with extrapulmonary (hilar to mediastinal) nodal metastasis (7.9%) than in cases without extrapulmonary metastasis (0.5%; p=0.01). Metastasis outside tumor-bearing segments was not observed in 64 tumors with pure or mixed ground glass opacity features on computed tomography. Although tumor location (peripheral or central/intermediate) was not related to the incidence of metastasis outside tumor-bearing segments, intrapulmonary spread was observed in only 1 of 52 peripheral small (≤20 mm) tumors. Metastasis outside tumor-bearing segments is rarely observed in cases with tumors (1) without extrapulmonary nodal metastasis and (2) with ground glass opacity or peripheral small (≤20 mm) features. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Comparison of volume estimation methods for pancreatic islet cells
NASA Astrophysics Data System (ADS)
Dvořák, JiřÃ.; Å vihlík, Jan; Habart, David; Kybic, Jan
2016-03-01
In this contribution we study different methods of automatic volume estimation for pancreatic islets which can be used in the quality control step prior to the islet transplantation. The total islet volume is an important criterion in the quality control. Also, the individual islet volume distribution is interesting -- it has been indicated that smaller islets can be more effective. A 2D image of a microscopy slice containing the islets is acquired. The input of the volume estimation methods are segmented images of individual islets. The segmentation step is not discussed here. We consider simple methods of volume estimation assuming that the islets have spherical or ellipsoidal shape. We also consider a local stereological method, namely the nucleator. The nucleator does not rely on any shape assumptions and provides unbiased estimates if isotropic sections through the islets are observed. We present a simulation study comparing the performance of the volume estimation methods in different scenarios and an experimental study comparing the methods on a real dataset.
NASA Astrophysics Data System (ADS)
Wu, Bin; Li, Xin; Do, Changwoo; Kim, Tae-Hwan; Shew, Chwen-Yang; Liu, Yun; Yang, Jun; Hong, Kunlun; Porcar, Lionel; Chen, Chun-Yu; Liu, Emily L.; Smith, Gregory S.; Herwig, Kenneth W.; Chen, Wei-Ren
2011-10-01
An experimental scheme using contrast variation small angle neutron scattering technique is developed to investigate the structural characteristics of amine-terminated poly(amidoamine) dendrimers solutions. Using this methodology, we present the dependence of both the intra-dendrimer water and the polymer distribution on molecular protonation, which can be precisely adjusted by tuning the pH of the solution. Assuming spherical symmetry of the spatial arrangement of the constituent components of dendrimer, and that the atomic ratio of hydrogen-to-deuterium for the solvent residing within the cavities of dendrimer is identical to that for the solvent outside the dendrimer, the intra-dendrimer water distribution along the radial direction is determined. Our result clearly reveals an outward relocation of the peripheral groups, as well as enhanced intra-dendrimer hydration, upon increasing the molecular protonation and, therefore, allows the determination of segmental backfolding in a quantitative manner. The connection between these charge-induced structural changes and our recently observed progressively active segmental dynamics is also discussed.
Oil droplets of bird eyes: microlenses acting as spectral filters
Stavenga, Doekele G.; Wilts, Bodo D.
2014-01-01
An important component of the cone photoreceptors of bird eyes is the oil droplets located in front of the visual-pigment-containing outer segments. The droplets vary in colour and are transparent, clear, pale or rather intensely yellow or red owing to various concentrations of carotenoid pigments. Quantitative modelling of the filter characteristics using known carotenoid pigment spectra indicates that the pigments’ absorption spectra are modified by the high concentrations that are present in the yellow and red droplets. The high carotenoid concentrations not only cause strong spectral filtering but also a distinctly increased refractive index at longer wavelengths. The oil droplets therefore act as powerful spherical microlenses, effectively channelling the spectrally filtered light into the photoreceptor's outer segment, possibly thereby compensating for the light loss caused by the spectral filtering. The spectral filtering causes narrow-band photoreceptor spectral sensitivities, which are well suited for spectral discrimination, especially in birds that have feathers coloured by carotenoid pigments. PMID:24395968
Transient shear viscosity of weakly aggregating polystyrene latex dispersions
NASA Astrophysics Data System (ADS)
de Rooij, R.; Potanin, A. A.; van den Ende, D.; Mellema, J.
1994-04-01
The transient behavior of the viscosity (stress growth) of a weakly aggregating polystyrene latex dispersion after a step from a high shear rate to a lower shear rate has been measured and modeled. Single particles cluster together into spherical fractal aggregates. The steady state size of these aggregates is determined by the shear stresses exerted on the latter by the flow field. The restructuring process taking place when going from a starting situation with monodisperse spherical aggregates to larger monodisperse spherical aggregates is described by the capture of primary fractal aggregates by growing aggregates until a new steady state is reached. It is assumed that the aggregation mechanism is diffusion limited. The model is valid if the radii of primary aggregates Rprim are much smaller than the radii of the growing aggregates. Fitting the model to experimental data at two volume fractions and a number of step sizes in shear rate yielded physically reasonable values of Rprim at fractal dimensions 2.1≤df≤2.2. The latter range is in good agreement with the range 2.0≤df≤2.3 obtained from steady shear results. The experimental data have also been fitted to a numerical solution of the diffusion equation for primary aggregates for a cell model with moving boundary, also yielding 2.1≤df≤2.2. The range for df found from both approaches agrees well with the range df≊2.1-2.2 determined from computer simulations on diffusion-limited aggregation including restructuring or thermal breakup after formation of bonds. Thus a simple model has been put forward which may capture the basic features of the aggregating model dispersion on a microstructural level and leads to physically acceptable parameter values.
Kuijt, Wichert J; Green, Cindy L; Verouden, Niels J W; Haeck, Joost D E; Tzivoni, Dan; Koch, Karel T; Stone, Gregg W; Lansky, Alexandra J; Broderick, Samuel; Tijssen, Jan G P; de Winter, Robbert J; Roe, Matthew T; Krucoff, Mitchell W
ST-segment recovery (STR) is a strong mechanistic correlate of infarct size (IS) and outcome in ST-segment elevation myocardial infarction (STEMI). Characterizing measures of speed, amplitude, and completeness of STR may extend the use of this noninvasive biomarker. Core laboratory continuous 24-h 12-lead Holter ECG monitoring, IS by single-photon emission computed tomography (SPECT), and 30-day mortality of 2 clinical trials of primary percutaneous coronary intervention in STEMI were combined. Multiple ST measures (STR at last contrast injection (LC) measured from peak value; 30, 60, 90, 120, and 240min, residual deviation; time to steady ST recovery; and the 3-h area under the time trend curve [ST-AUC] from LC) were univariably correlated with IS and predictive of mortality. After multivariable adjustment for ST-parameters and GRACE risk factors, STR at 240min remained an additive predictor of mortality. Early STR, residual deviation, and ST-AUC remained associated with IS. Multiple parameters that quantify the speed, amplitude, and completeness of STR predict mortality and correlate with IS. Copyright © 2017. Published by Elsevier Inc.
Primary Acquired Melanosis: Clinical, Histopathologic and Optical Coherence Tomographic Correlation
Alzahrani, Yahya A.; Kumar, Smita; Abdul Aziz, Hassan; Plesec, Thomas; Singh, Arun D.
2016-01-01
Aim To assess the use of anterior segment optical coherence tomography (OCT) as an adjuvant diagnostic tool in primary acquired melanosis (PAM) by correlating clinical, histopathologic and anterior segment OCT findings. Methods Twenty-four patients (24 eyes) with PAM of the conjunctiva, cornea or both were imaged with an anterior segment OCT device (RTVue, model-RT100; Optovue Inc., Fremont, Calif., USA). Results Histopathologic diagnosis following excisional or incisional biopsy was confirmed in 13 out of 24 patients (54.6%). OCT images showed a characteristic uniformly thick basal epithelial hyperreflective band (about 20 μm thick) and normal thickness of the overlying epithelial layer in all patients (100%). The hyperreflective band on OCT correlated with the basal epithelial melanocytic pigmentation noted on histopathologic examination but did not vary in thickness between cases with or without atypia. Conclusions The characteristic basal epithelial hyperreflective band with normal overlying epithelium in the absence of cysts observed in all cases by anterior segment OCT correlated with clinical and histopathologic features of conjunctival and corneal PAM. Anterior segment OCT may be helpful as a noninvasive diagnostic tool for PAM. Improvement in resolution is necessary to detect melanocytic hyperplasia and aytpia suggestive of malignant potential. PMID:27390743
Optical Analysis of an Ultra-High resolution Two-Mirror Soft X-Ray Microscope
NASA Technical Reports Server (NTRS)
Shealy, David L.; Wang, Cheng; Hoover, Richard B.
1994-01-01
This work has summarized for a Schwarzschild microscope some relationships between numerical aperture (NA), magnification, diameter of the primary mirror, radius of curvature of the secondary mirror, and the total length of the microscope. To achieve resolutions better than a spherical Schwarzschild microscope of 3.3 Lambda for a perfectly aligned and fabricated system. it is necessary to use aspherical surfaces to control higher-order aberrations. For an NA of 0.35, the aspherical Head microscope provides diffraction limited resolution of 1.4 Lambda where the aspherical surfaces differ from the best fit spherical surface by approximately 1 micrometer. However, the angle of incidence varies significantly over the primary and the secondary mirrors, which will require graded multilayer coatings to operate near peak reflectivities. For higher numerical apertures, the variation of the angle of incidence over the secondary mirror surface becomes a serious problem which must be solved before multilayer coatings can be used for this application. Tolerance analysis of the spherical Schwarzschild microscope has shown that water window operations will require 2-3 times tighter tolerances to achieve a similar performance for operations with 130 A radiation. Surface contour errors have been shown to have a significant impact on the MTF and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror.
Geometrical characterization of perlite-metal syntactic foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovinšek, Matej, E-mail: matej.borovinsek@um.si
This paper introduces an improved method for the detailed geometrical characterization of perlite-metal syntactic foam. This novel metallic foam is created by infiltrating a packed bed of expanded perlite particles with liquid aluminium alloy. The geometry of the solidified metal is thus defined by the perlite particle shape, size and morphology. The method is based on a segmented micro-computed tomography data and allows for automated determination of the distributions of pore size, sphericity, orientation and location. The pore (i.e. particle) size distribution and pore orientation is determined by a multi-criteria k-nearest neighbour algorithm for pore identification. The results indicate amore » weak density gradient parallel to the casting direction and a slight preference of particle orientation perpendicular to the casting direction. - Highlights: •A new method for identification of pores in porous materials was developed. •It was applied on perlite-metal syntactic foam samples. •A porosity decrease in the axial direction of the samples was determined. •Pore shape analysis showed a high percentage of spherical pores. •Orientation analysis showed that more pores are oriented in the radial direction.« less
EEG-distributed inverse solutions for a spherical head model
NASA Astrophysics Data System (ADS)
Riera, J. J.; Fuentes, M. E.; Valdés, P. A.; Ohárriz, Y.
1998-08-01
The theoretical study of the minimum norm solution to the MEG inverse problem has been carried out in previous papers for the particular case of spherical symmetry. However, a similar study for the EEG is remarkably more difficult due to the very complicated nature of the expression relating the voltage differences on the scalp to the primary current density (PCD) even for this simple symmetry. This paper introduces the use of the electric lead field (ELF) on the dyadic formalism in the spherical coordinate system to overcome such a drawback using an expansion of the ELF in terms of longitudinal and orthogonal vector fields. This approach allows us to represent EEG Fourier coefficients on a 2-sphere in terms of a current multipole expansion. The choice of a suitable basis for the Hilbert space of the PCDs on the brain region allows the current multipole moments to be related by spatial transfer functions to the PCD spectral coefficients. Properties of the most used distributed inverse solutions are explored on the basis of these results. Also, a part of the ELF null space is completely characterized and those spherical components of the PCD which are possible silent candidates are discussed.
Zonal Flow Velocimetry in Spherical Couette Flow using Acoustic Modes
NASA Astrophysics Data System (ADS)
Adams, Matthew M.; Mautino, Anthony R.; Stone, Douglas R.; Triana, Santiago A.; Lekic, Vedran; Lathrop, Daniel P.
2015-11-01
We present studies of spherical Couette flows using the technique of acoustic mode Doppler velocimetry. This technique uses rotational splittings of acoustic modes to infer the azimuthal velocity profile of a rotating flow, and is of special interest in experiments where direct flow visualization is impractical. The primary experimental system consists of a 60 cm diameter outer spherical shell concentric with a 20 cm diameter sphere, with air or nitrogen gas serving as the working fluid. The geometry of the system approximates that of the Earth's core, making these studies geophysically relevant. A turbulent shear flow is established in the system by rotating the inner sphere and outer shell at different rates. Acoustic modes of the fluid volume are excited using a speaker and measured via microphones, allowingdetermination of rotational splittings. Preliminary results comparing observed splittings with those predicted by theory are presented. While the majority of these studies were performed in the 60 cm diameter device using nitrogen gas, some work has also been done looking at acoustic modes in the 3 m diameter liquid sodium spherical Couette experiment. Prospects for measuring zonal velocity profiles in a wide variety of experiments are discussed.
FUV Detection of the Primary Star of eta Carinae
NASA Astrophysics Data System (ADS)
Davidson, K.; Smith, N.
2006-06-01
Using FUSE data, Iping et al (2005, ApJ 633, L37) report a direct detection of the elusive hot companion of eta Car. We argue, however, that much of the observed emission represents the primary star, with no proof that any of it comes from a secondary star. The hypothetical companion should dominate the ionizing radiation below 912 A, but this is not true for wavelengths around 1100 A observed with FUSE. Moreover, since a companion's UV would be partially reprocessed by the primary star's wind, any detection is likely to be ambiguous.The non-spherical primary wind allows production of strong UV radiation at low latitudes (Smith et al 2003, ApJ 586, 432), an effect that spherical models don't include. The N II 1085 feature, the relatively slow wind velocities seen by FUSE, and other details are characteristic of the primary wind, not the secondary. Zanella et al. (1984, A&A 137, 79) suggested that eta Car's far UV disappears during a spectroscopic event due to a shell ejection. The FUSE observations may be regarded as confirmation of that conjecture, which made no reference to a secondary star. The 2003 spectroscopic event was probably a mass ejection or a wind-disturbance episode, not merely an eclipse as assumed by Iping et al. A hot companion star seems likely to account for the ionizing UV and the X-ray variability, but the FUSE data do not confirm its existence.
Bangalore, Sripal; Pencina, Michael J; Kleiman, Neal S; Cohen, David J
2014-06-01
The use of bivalirudin versus unfractionated heparin monotherapy in patients without ST-segment-elevation myocardial infarction is not well defined. The study population consisted of patients enrolled in the Evaluation of Drug-Eluting Stents and Ischemic Events (EVENT) registry with either non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease, who underwent percutaneous coronary intervention with either unfractionated heparin or bivalirudin monotherapy. Propensity score matching was used to adjust for baseline characteristics. The primary bleeding (in-hospital composite bleeding-access site bleeding, thrombolysis in myocardial infarction major/minor bleeding, or transfusion) and primary (in-hospital death/myocardial infarction) and secondary ischemic outcomes (death/myocardial infarction/unplanned repeat revascularization at 12 months) were evaluated. Propensity score matching yielded 1036 patients with non-ST-segment-elevation acute coronary syndromes and 2062 patients with stable ischemic heart disease. For the non-ST-segment-elevation acute coronary syndrome cohort, bivalirudin use was associated with lower bleeding (difference, -3.3% [-0.8% to -5.8%]; P=0.01; number need to treat=30) without increase in either primary (difference, 1.2% [4.1% to -1.8%]; P=0.45) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [1.3% to -1.3%]; P=1.00). Similarly, in the stable ischemic heart disease cohort, bivalirudin use was associated with lower bleeding (difference, -1.8% [-0.4% to -3.3%]; P=0.01; number need to treat=53) without increase in either primary (difference, 0.4% [2.3% to -1.5%]; P=0.70) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [0.7% to -0.7%]; P=1.00) when compared with unfractionated heparin monotherapy. Among patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease undergoing percutaneous coronary intervention, bivalirudin use during percutaneous coronary intervention when compared with unfractionated heparin monotherapy was associated with lower bleeding without significant increase in ischemic outcomes or stent thrombosis. © 2014 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Joghan, Hamed Dardaei; Staupendahl, Daniel; Hassan, Hamad ul; Henke, Andreas; Keesser, Thorsten; Legat, Francois; Tekkaya, A. Erman
2018-05-01
Tube hydroforming is one of the most important manufacturing processes for the production of exhaust systems. Tube hydroforming allows generating parts with highly complex geometries with the forming accuracies needed in the automotive sector. This is possible due to the form-closed nature of the production process. One of the main cost drivers is tool manufacturing, which is expensive and time consuming, especially when forming large parts. To cope with the design trend of individuality, which is gaining more and more importance and leads to a high number of product variants, a new flexible tool design was developed. The designed tool offers a high flexibility in manufacturing different shapes and geometries of tubes with just local alterations and relocation of tool segments. The tolerancing problems that segmented tools from the state of the art have are overcome by an innovative and flexible die holder design. The break-even point of this initially more expensive tool design is already overcome when forming more than 4 different tube shapes. Together with an additionally designed rotary hydraulic tube feeding system, a highly adaptable forming setup is generated. To investigate the performance of the developed tool setup, a study on geometrical and process parameters during forming of a spherical dome was done. Austenitic stainless steel (grade 1.4301) tube with a diameter of 40 mm and a thickness of 1.5 mm was used for the investigations. The experimental analyses were supported by finite element simulations and statistical analyses. The results show that the flexible tool setup can efficiently be used to analyze the interaction of the inner pressure, friction, and the location of the spherical dome and demonstrate the high influence of the feeding rate on the formed part.
Oscillatory Extinction Of Spherical Diffusion Flames
NASA Technical Reports Server (NTRS)
Law, C. K.; Yoo, S. W.; Christianson, E. W.
2003-01-01
Since extinction has been observed in an oscillatory manner in Le greater than 1 premixed flames, it is not unreasonable to expect that extinction could occur in an unsteady manner for diffusion flames. Indeed, near-limit oscillations have been observed experimentally under microgravity conditions for both candle flames and droplet flames. Furthermore, the analysis of Cheatham and Matalon on the unsteady behavior of diffusion flames with heat loss, identified an oscillatory regime which could be triggered by either a sufficiently large Lewis number (even without heat loss) or an appreciable heat loss (even for Le=1). In light of these recent understanding, the present investigation aims to provide a well-controlled experiment that can unambiguously demonstrate the oscillation of diffusion flames near both the transport- and radiation-induced limits. That is, since candle and jet flames are stabilized through flame segments that are fundamentally premixed in nature, and since premixed flames are prone to oscillate, there is the possibility that the observed oscillation of these bulk diffusion flames could be triggered and sustained by the oscillation of the premixed flame segments. Concerning the observed oscillatory droplet extinction, it is well-known that gas-phase oscillation in heterogeneous burning can be induced by and is thereby coupled with condensed-phase unsteadiness. Consequently, a convincing experiment on diffusion flame oscillation must exclude any ingredients of premixed flames and other sources that may either oscillate themselves or promote the oscillation of the diffusion flame. The present experiment on burner-generated spherical flames with a constant reactant supply endeavored to accomplish this goal. The results are further compared with those from computational simulation for further understanding and quantification of the flame dynamics and extinction.
Gonté, Frédéric; Dupuy, Christophe; Luong, Bruno; Frank, Christoph; Brast, Roland; Sedghi, Baback
2009-11-10
The primary mirror of the future European Extremely Large Telescope will be equipped with 984 hexagonal segments. The alignment of the segments in piston, tip, and tilt within a few nanometers requires an optical phasing sensor. A test bench has been designed to study four different optical phasing sensor technologies. The core element of the test bench is an active segmented mirror composed of 61 flat hexagonal segments with a size of 17 mm side to side. Each of them can be controlled in piston, tip, and tilt by three piezoactuators with a precision better than 1 nm. The context of this development, the requirements, the design, and the integration of this system are explained. The first results on the final precision obtained in closed-loop control are also presented.
Social Marketing, Stages of Change, and Public Health Smoking Interventions
ERIC Educational Resources Information Center
Diehr, Paula; Hannon, Peggy; Pizacani, Barbara; Forehand, Mark; Meischke, Hendrika; Curry, Susan; Martin, Diane P.; Weaver, Marcia R.; Harris, Jeffrey
2011-01-01
As a "thought experiment," the authors used a modified stages of change model for smoking to define homogeneous segments within various hypothetical populations. The authors then estimated the population effect of public health interventions that targeted the different segments. Under most assumptions, interventions that emphasized primary and…
Coskunseven, Efekan; Jankov, Mirko R; Grentzelos, Michael A; Plaka, Argyro D; Limnopoulou, Aliki N; Kymionis, George D
2013-01-01
To present the results of topography-guided transepithelial photorefractive keratectomy (PRK) after intracorneal ring segments implantation followed by corneal collagen cross-linking (CXL) for keratoconus. In this prospective case series, 10 patients (16 eyes) with progressive keratoconus were included. All patients underwent topography-guided transepithelial PRK after Keraring intracorneal ring segments (Mediphacos Ltda) implantation, followed by CXL treatment. The follow-up period was 6 months after the last procedure for all patients. Time interval between both intracorneal ring segments implantation and CXL and between CXL and topography-guided transepithelial PRK was 6 months. LogMAR mean uncorrected distance visual acuity and mean corrected distance visual acuity were significantly improved (P<.05) from 1.14±0.36 and 0.75±0.24 preoperatively to 0.25±0.13 and 0.13±0.06 after the completion of the three-step procedure, respectively. Mean spherical equivalent refraction was significantly reduced (P<.05) from -5.66±5.63 diopters (D) preoperatively to -0.98±2.21 D after the three-step procedure. Mean steep and flat keratometry values were significantly reduced (P<.05) from 54.65±5.80 D and 47.80±3.97 D preoperatively to 45.99±3.12 D and 44.69±3.19 D after the three-step procedure, respectively. Combined topography-guided transepithelial PRK with intracorneal ring segments implantation and CXL in a three-step procedure seems to be an effective, promising treatment sequence offering patients a functional visual acuity and ceasing progression of the ectatic disorder. A longer follow-up and larger case series are necessary to thoroughly evaluate safety, stability, and efficacy of this innovative procedure. Copyright 2013, SLACK Incorporated.
Bartesaghi, Alberto; Sapiro, Guillermo; Subramaniam, Sriram
2006-01-01
Electron tomography allows for the determination of the three-dimensional structures of cells and tissues at resolutions significantly higher than that which is possible with optical microscopy. Electron tomograms contain, in principle, vast amounts of information on the locations and architectures of large numbers of subcellular assemblies and organelles. The development of reliable quantitative approaches for the analysis of features in tomograms is an important problem, and a challenging prospect due to the low signal-to-noise ratios that are inherent to biological electron microscopic images. This is, in part, a consequence of the tremendous complexity of biological specimens. We report on a new method for the automated segmentation of HIV particles and selected cellular compartments in electron tomograms recorded from fixed, plastic-embedded sections derived from HIV-infected human macrophages. Individual features in the tomogram are segmented using a novel robust algorithm that finds their boundaries as global minimal surfaces in a metric space defined by image features. The optimization is carried out in a transformed spherical domain with the center an interior point of the particle of interest, providing a proper setting for the fast and accurate minimization of the segmentation energy. This method provides tools for the semi-automated detection and statistical evaluation of HIV particles at different stages of assembly in the cells and presents opportunities for correlation with biochemical markers of HIV infection. The segmentation algorithm developed here forms the basis of the automated analysis of electron tomograms and will be especially useful given the rapid increases in the rate of data acquisition. It could also enable studies of much larger data sets, such as those which might be obtained from the tomographic analysis of HIV-infected cells from studies of large populations. PMID:16190467
Manavella, Valeria; Romano, Federica; Garrone, Federica; Terzini, Mara; Bignardi, Cristina; Aimetti, Mario
2017-06-01
The aim of this study was to present and validate a novel procedure for the quantitative volumetric assessment of extraction sockets that combines cone-beam computed tomography (CBCT) and image processing techniques. The CBCT dataset of 9 severely resorbed extraction sockets was analyzed by means of two image processing software, Image J and Mimics, using manual and automated segmentation techniques. They were also applied on 5-mm spherical aluminum markers of known volume and on a polyvinyl chloride model of one alveolar socket scanned with Micro-CT to test the accuracy. Statistical differences in alveolar socket volume were found between the different methods of volumetric analysis (P<0.0001). The automated segmentation using Mimics was the most reliable and accurate method with a relative error of 1.5%, considerably smaller than the error of 7% and of 10% introduced by the manual method using Mimics and by the automated method using ImageJ. The currently proposed automated segmentation protocol for the three-dimensional rendering of alveolar sockets showed more accurate results, excellent inter-observer similarity and increased user friendliness. The clinical application of this method enables a three-dimensional evaluation of extraction socket healing after the reconstructive procedures and during the follow-up visits.
W. M. Keck Observatory primary mirror segment repair project: overview and status
NASA Astrophysics Data System (ADS)
Meeks, Robert L.; Doyle, Steve; Higginson, Jamie; Hudek, John S.; Irace, William; McBride, Dennis; Pollard, Mike; Tai, Kuochou; Von Boeckmann, Tod; Wold, Leslie; Wold, Truman
2016-07-01
The W. M. Keck Observatory Segment Repair Project is repairing stress-induced fractures near the support points in the primary mirror segments. The cracks are believed to result from deficiencies in the original design and implementation of the adhesive joints connecting the Invar support components to the ZERODUR mirror. Stresses caused by temperature cycling over 20 years of service drove cracks that developed at the glass-metal interfaces. Over the last few years the extent and cause of the cracks have been studied, and new supports have been designed. Repair of the damaged glass required development of specialized tools and procedures for: (1) transport of the segments; (2) pre-repair metrology to establish the initial condition; (3) removal of support hardware assemblies; (4) removal of the original supports; (5) grinding and re-surfacing the damaged glass areas; (6) etching to remove sub-surface damage; (7) bonding new supports; (8) re-installation of support assemblies; and (9) post-repair metrology. Repair of the first segment demonstrated the new tools and processes. On-sky measurements before and after repair verified compliance with the requirements. This paper summarizes the repair process, on-sky results, and transportation system, and also provides an update on the project status and schedule for repairing all 84 mirror segments. Strategies for maintaining quality and ensuring that repairs are done consistently are also presented.
Keyboard Literacy for Hawaii's Primary Children
ERIC Educational Resources Information Center
Oksendahl, Wilma J.
1972-01-01
Article discusses some of the previous experiments in elementary typewriting, the background of the Hawaii English Program, particularly the Language Skills segment, and the Primary Typewriting Program--its rationale, materials and equipment, results and limitations. (Author/CB)
Recuperator construction for a gas turbine engine
Kang, Yungmo; McKeirnan, Jr., Robert D.
2006-12-12
A counter-flow recuperator formed from annular arrays of recuperator core segments. The recuperator core segments are formed from two opposing sheets of fin fold material coined to form a primary surface zone disposed between two flattened manifold zones. Each primary surface zone has undulating corrugations including a uniform, full height central portion and a transition zone disposed between the central portion and one of the manifold zones. Corrugations of the transition zone rise from zero adjacent to the manifold zone and increase along a transition length to full crest height at the central portion. The transition lengths increase in a direction away from an inner edge containing the air inlet so as to equalize air flow to the distal regions of the primary surface zone.
A Typology of Middle School Girls: Audience Segmentation Related to Physical Activity
Staten, Lisa K.; Birnbaum, Amanda S.; Jobe, Jared B.; Elder, John P.
2008-01-01
The Trial of Activity for Adolescent Girls (TAAG) combines social ecological and social marketing approaches to promote girls’ participation in physical activity programs implemented at 18 middle schools throughout the United States. Key to the TAAG approach is targeting materials to a variety of audience segments. TAAG segments are individuals who share one or more common characteristic that is expected to correlate with physical activity. Thirteen focus groups with seventh and eighth grade girls were conducted to identify and characterize segments. Potential messages and channels of communication were discussed for each segment. Based on participant responses, six primary segments were identified: athletic, preppy, quiet, rebel, smart, and tough. The focus group information was used to develop targeted promotional tools to appeal to a diversity of girls. Using audience segmentation for targeting persuasive communication is potentially useful for intervention programs but may be sensitive; therefore, ethical issues must be critically examined. PMID:16397160
Analysis and Verification of HET 1 m Mirror Deflections Due to Edge Sensor Loading
NASA Technical Reports Server (NTRS)
Stallcup, Michael A.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
The ninety-one 1 m mirror segments which comprise the McDonald Observatory Hobby Eberly Telescope (HET) primary mirror have been observed to drift out of alignment in an unpredictable manner in response to time variant temperature deviations. A Segment Alignment Maintenance System (SAMS) is being developed to detect and correct this segment-to-segment drift using sensors mounted at the edges of the mirror segments. However, the segments were not originally designed to carry the weight of edge sensors. Thus, analyses and tests were conducted as part of the SAMS design to estimate the magnitude and shape of the edge sensor induced deformations as well as the resultant optical performance. Interferometric testing of a 26 m radius of curvature HET mirror segment was performed at the Marshall Space Flight Center using several load conditions to verify the finite element analyses.
A typology of middle school girls: audience segmentation related to physical activity.
Staten, Lisa K; Birnbaum, Amanda S; Jobe, Jared B; Elder, John P
2006-02-01
The Trial of Activity for Adolescent Girls (TAAG) combines social ecological and social marketing approaches to promote girls' participation in physical activity programs implemented at 18 middle schools throughout the United States. Key to the TAAG approach is targeting materials to a variety of audience segments. TAAG segments are individuals who share one or more common characteristic that is expected to correlate with physical activity. Thirteen focus groups with seventh and eighth grade girls were conducted to identify and characterize segments. Potential messages and channels of communication were discussed for each segment. Based on participant responses, six primary segments were identified: athletic, preppy, quiet, rebel, smart, and tough. The focus group information was used to develop targeted promotional tools to appeal to a diversity of girls. Using audience segmentation for targeting persuasive communication is potentially useful for intervention programs but may be sensitive; therefore, ethical issues must be critically examined.
First results of the wind evaluation breadboard for ELT primary mirror design
NASA Astrophysics Data System (ADS)
Reyes García-Talavera, Marcos; Viera, Teodora; Núñez, Miguel
2010-07-01
The Wind Evaluation Breadboard (WEB) is a primary mirror and telescope simulator formed by seven aluminium segments, including position sensors, electromechanical support systems and support structures. WEB has been developed to evaluate technologies for primary mirror wavefront control and to evaluate the performance of the control of wind buffeting disturbance on ELT segmented mirrors. For this purpose WEB electro-mechanical set-up simulates the real operational constrains applied to large segmented mirrors. This paper describes the WEB assembly, integration and verification, the instrument characterisation and close loop control design, including the dynamical characterization of the instrument and the control architecture. The performance of the new technologies developed for position sensing, acting and controlling is evaluated. The integration of the instrument in the observatory and the results of the first experiments are summarised, with different wind conditions, elevation and azimuth angles of incidence. Conclusions are extracted with respect the wind rejection performance and the control strategy for an ELT. WEB has been designed and developed by IAC, ESO, ALTRAN and JUPASA, with the integration of subsystems of FOGALE and TNO.
Spherical Viscoelastic Finite Element Model for Cascadia Interseismic Deformation
NASA Astrophysics Data System (ADS)
He, J.; Wang, K.; Dragert, H.; Miller, M. M.
2003-12-01
We have developed a 3-D spherical viscoelastic finite element model for the Cascadia subduction zone to study temporal and spatial variations of interseismic deformation. Previous 3-D viscoelastic finite element models of subduction zone earthquake cycles all use the Cartesian system, with the surface of the earth map-projected on to a horizontal plane. For earthquakes that rupture very long plate-boundary segments, such as the 1700 Cascadia, 1960 Chile, and 1964 Alaska great earthquakes, the Cartesian approach is inconvenient and less accurate. 3-D analytical solutions take into account the spherical geometry of the earth but have difficulty dealing with realistic plate boundary structure. For the new spherical finite element model, we use 27-node tri-quadratic isoparametric element. The resultant large sparse matrix system is solved by the stabilized bi-conjugate gradient method with ILUT preconditioning of fill-in level 6. Our experience suggests that lower order elements in the spherical system would result in unacceptable numerical errors unless one set of mesh lines is strictly radial. For the great Cascadia earthquake, we employ a smooth coseismic rupture model inferred from thermal data and results of tsunami models of the 1700 event, but we test different slip distances. For interseismic deformation, we use the conventional backslip approach. The contemporary deformation of the Cascadia margin consists of interseismic strain accumulation and a geological secular motion that can be described by a rotation of the forearc relative to North America. To isolate the interseismic deformation, we remove the secular motion from both the model formulation and geodetic data. The model predicts decreasing margin-normal shortening rates throughout the interseismic period as a result of stress relaxation in the viscoelastic mantle. The rate of decrease depends on the assumed mantle viscosity. With a viscosity of 1019 Pa s, model surface deformation at 300 years after the great earthquake agrees with geodetically observed contemporary deformation very well. The model also confirms the previous finding based on a Cartesian model that an inland region continues to move seaward several decades after the great earthquake.
Axisymmetric Optical Membrane Modeling Based on Experimental Results
2004-03-01
polymers; one such was NASA’s Inflatable Antenna Experiment (IAE), which is a pressurized lenticular about 14 meters in diameter. It was designed...2cos2θ Astigmatism with axis at +/- 45 deg 5 ρ 2sin2θ Astigmatism with axis at +/- 0 or 90 deg 6 (3 ρ 2-2) ρ cosθ Primary coma along y axis...7 (3 ρ 2-2) ρ sinθ Primary coma along x axis 51 8 6 ρ 4-6 ρ 2+1 Primary spherical aberration 9 ρ 3cos(3θ ) Triangular astigmatism , base on y axis
Anderst, William
2016-01-01
Arthrodesis is the standard of care for numerous pathologic conditions of the cervical spine and is performed over 150,000 times annually in the United States. The primary long-term concern after this surgery is adjacent segment disease (ASD), defined as new clinical symptoms adjacent to a previous fusion. The incidence of adjacent segment disease is approximately 3% per year, meaning that within 10 years of the initial surgery, approximately 25% of cervical arthrodesis patients require a second procedure to address symptomatic adjacent segment degeneration. Despite the high incidence of ASD, until recently, there was little data available to characterize in vivo adjacent segment mechanics during dynamic motion. This manuscript reviews recent advances in our knowledge of adjacent segment mechanics after cervical arthrodesis that have been facilitated by the use of dynamic biplane radiography. The primary observations from these studies are that current in vitro test paradigms often fail to replicate in vivo spine mechanics before and after arthrodesis, that intervertebral mechanics vary among cervical motion segments, and that joint arthrokinematics (i.e., the interactions between adjacent vertebrae) are superior to traditional kinematics measurements for identifying altered adjacent segment mechanics after arthrodesis. Future research challenges are identified, including improving the biofidelity of in vitro tests, determining the natural history of in vivo spine mechanics, conducting prospective longitudinal studies on adjacent segment kinematics and arthrokinematics after single and multiple-level arthrodesis, and creating subject-specific computational models to accurately estimate muscle forces and tissue loading in the spine during dynamic activities. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Tracking Organs Composed of One or Multiple Regions Using Geodesic Active Region Models
NASA Astrophysics Data System (ADS)
Martínez, A.; Jiménez, J. J.
In radiotherapy treatment it is very important to find out the target organs on the medical image sequence in order to determine and apply the proper dose. The techniques to achieve this goal can be classified into extrinsic and intrinsic. Intrinsic techniques only use image processing with medical images associated to the radiotherapy
Morphology, topography, and optics of the orthokeratology cornea
NASA Astrophysics Data System (ADS)
Faria-Ribeiro, Miguel; Belsue, Rafael Navarro; López-Gil, Norberto; González-Méijome, José Manuel
2016-07-01
The goal of this work was to objectively characterize the external morphology, topography, and optics of the cornea after orthokeratology (ortho-k). A number of 24 patients between the ages of 17 and 30 years (median=24 years) were fitted with Corneal Refractive Therapy® contact lenses to correct myopia between -2.00 and -5.00 diopters (D) (median=-3.41 D). A classification algorithm was applied to conduct an automatic segmentation based on the mean local curvature. As a result, three zones (optical zone, transition zone, and peripheral zone) were delimited. Topographical analysis was provided through global and zonal fit to a general ellipsoid. Ray trace on partially customized eye models provided wave aberrations and retinal image quality. Monozone topographic description of the ortho-k cornea loses accuracy when compared with zonal description. Primary (C40) and secondary (C60) spherical aberration (SA) coefficients for a 5-mm pupil increased 3.68 and 19 times, respectively, after the treatments. The OZ area showed a strong correlation with C40 (r=-0.49, p<0.05) and a very strong correlation with C60 (r=0.78, p<0.01). The OZ, as well as the TZ, areas did not correlate with baseline refraction. The increase in the eye's positive SA after ortho-k is the major factor responsible for the decreased retinal optical quality of the unaccommodated eye.
Segmenting the Net-Generation: Embracing the Next Level of Technology
ERIC Educational Resources Information Center
Smith, Russell K.
2014-01-01
A segmentation study is used to partition college students into groups that are more or less likely to adopt tablet technology as a learning tool. Because the college population chosen for study presently relies upon laptop computers as their primary learning device, tablet technology represents a "next step" in technology. Student…
NASA Technical Reports Server (NTRS)
Partridge, James D.
2002-01-01
'NASA is preparing to launch the Next Generation Space Telescope (NGST). This telescope will be larger than the Hubble Space Telescope, be launched on an Atlas missile rather than the Space Shuttle, have a segmented primary mirror, and be placed in a higher orbit. All these differences pose significant challenges.' This effort addresses the challenge of implementing an algorithm for aligning the segments of the primary mirror during the initial deployment that was designed by Philip Olivier and members of SOMTC (Space Optics Manufacturing Technology Center). The implementation was to be performed on the SIBOA (Systematic Image Based Optical Alignment) test bed. Unfortunately, hardware/software aspect concerning SIBOA and an extended time period for algorithm development prevented testing before the end of the study period. Properties of the digital camera were studied and understood, resulting in the current ability of selecting optimal settings regarding saturation. The study was successful in manually capturing several images of two stacked segments with various relative phases. These images can be used to calibrate the algorithm for future implementation. Currently the system is ready for testing.
NASA Astrophysics Data System (ADS)
Gersch, Alan M.; Feaga, Lori M.; A’Hearn, Michael F.
2018-02-01
We have adapted Coupled Escape Probability, a new exact method of solving radiative transfer problems, for use in asymmetrical spherical situations for use in modeling optically thick cometary comae. Here we present the extension of our model and corresponding results for two additional primary volatile species of interest, H2O and CO2, in purely theoretical comets. We also present detailed modeling and results for the specific examples of CO, H2O, and CO2 observations of C/2009 P1 Garradd by the Deep Impact flyby spacecraft.
Primary and Secondary Labor Markets: Implications for Vocational Rehabilitation.
ERIC Educational Resources Information Center
Hagner, David
2000-01-01
Reviews theoretical and empirical work in labor economics and the sociology of work relating to the segmentation of the labor market into a primary and a secondary sector and examines the implications for vocational rehabilitation. Transition into primary sector employment is explored as an important aspect of career development for individuals…
Inclusive Education: Proclamations or Reality (Primary School Teachers' View)
ERIC Educational Resources Information Center
Slavica, Pavlovic
2010-01-01
This paper deals with 2 focal points of inclusive education, which is the integral segment of the current education reform in the Bosnia and Herzegovina: its position in various proclamations and in primary school teachers' reality, i.e., legislative aspects vs. everyday situation in primary schools. The survey research was carried out through the…
Bodily Tides Near Spin-Orbit Resonances
2012-01-01
radial term may cause an equipotential - surface variation of about 10 cm. This magnitude is large enough to be observed by future missions and should...U (r) = ∞∑ l=2 Ul(r) = ∞∑ l=2 kl ( R r )l+1 Wl(R, r∗), (2) R now being the mean equatorial radius of the primary, R = (R, φ, λ) being a surface point...rheology. For a homogeneous incompressible spherical primary of density ρ, surface gravity g, and rigidity μ, the static Love number of degree l is
Aft segment dome-to-stiffener factory joint insulation void elimination
NASA Technical Reports Server (NTRS)
Jensen, S. K.
1991-01-01
Since the detection of voids in the internal insulation of the dome-to-stiffener factory joint of the 15B aft segment, all aft segment dome-to-stiffener factory joints were x-rated and all were found to contain voids. Using a full-scale process simulation article (PSA), the objective was to demonstrate that the proposed changes in the insulation layup and vacuum bagging processes will greatly reduce or eliminate voids without adversely affecting the configuration of performance of the insulation which serves as a primary seal over the factory joint. The PSA-8 aft segment was insulated and cured using standard production processes.
Primary nerve grafting: A study of revascularization.
Chalfoun, Charbel; Scholz, Thomas; Cole, Matthew D; Steward, Earl; Vanderkam, Victoria; Evans, Gregory R D
2003-01-01
It was the purpose of this study to evaluate the revascularization of primary nerve repair and grafts using orthogonal polarization spectral (OPS) (Cytometrix, Inc.) imaging, a novel method for real-time evaluation of microcirculatory blood flow. Twenty male Sprague Dawley rats (250 g) were anesthetized with vaporized halothane and surgically prepared for common peroneal nerve resection. Group I animals (n = 10) underwent primary neurorraphy following transection, utilizing a microsurgical technique with 10-0 nylon suture. Group II (n = 10) animals had a 7-mm segment of nerve excised, reversed, and subsequently replaced as a nerve graft under similar techniques. All animals were evaluated using the OPS imaging system on three portions (proximal, transection site/graft, and distal) of the nerve following repair or grafting. Reevaluation of 5 animals randomly selected from each group using the OPS imaging system was again performed on days 14 and 28 following microsurgical repair/grafting. Values were determined by percent change in vascularity of the common peroneal nerve at 0 hr following surgery. Real-time evaluation of blood flow was utilized as an additional objective criterion. Percent vascularity in group I and II animals increased from baseline in all segments at day 14. By day 28, vascularity in nerves of group I rats decreased in all segments to values below baseline, with the exception of the transection site, which remained at a higher value than obtained directly after surgical repair. In group II animals, vascularity remained above baseline in all segments except the distal segment, which returned to vascularity levels similar to those at 0 hr. Further, occlusion of the vessels demonstrated in the graft and distal segments following initial transection appeared to be corrected. This study suggests that revascularization may occur via bidirectional inosculation with favored proximal vascular growth advancement. The use of real-time imaging offers a unique evaluation of tissues through emerging technologies. Copyright 2003 Wiley-Liss, Inc.
Near work, outdoor activity, and their association with refractive error.
Lin, Zhong; Vasudevan, Balamurali; Jhanji, Vishal; Mao, Guang Yun; Gao, Tie Ying; Wang, Feng Hua; Rong, Shi Song; Ciuffreda, Kenneth J; Liang, Yuan Bo
2014-04-01
To assess the relationship between near work, outdoor activity, and refractive error in schoolchildren in Beijing. The Beijing Myopia Progression Study is a hospital-based myopia study, in which 386 students from primary (aged 6 to 12 years) and secondary (aged 13 to 17 years) schools in the inner city of Beijing were enrolled. Cycloplegic refraction and a detailed questionnaire probing near, intermediate, and distance visual activities were completed. Three hundred seventy (95.9%) of 386 students with complete cycloplegic autorefraction and myopia questionnaire data were enrolled in this study. Children with more near work time did not exhibit a significantly more myopic refraction in both the primary and secondary school levels after adjusting for the children's gender, outdoor activity time, and average parental refractive error. A significant association between outdoor activity time (in hours per day) and the children's spherical equivalent (in diopters) was found in the primary school students (β = 0.27, p = 0.03) but not in the secondary school students (β = 0.04, p = 0.70) after adjusting for similar confounders. The time spent on outdoor sports and outdoor leisure in the primary school students was also significantly associated with the children's spherical equivalent (β = 0.46, p = 0.04 and β = 0.31, p = 0.02, respectively). Primary school students with more time outdoors exhibited relatively less myopic refraction than their peers (ptrend = 0.0003), but this relation was not demonstrated in the secondary school children (ptrend = 0.53) after adjusting for similar confounders. Higher levels of outdoor activity were associated with less myopic refraction in primary school students in the inner city of Beijing. Near work activity was not found to be associated with refraction at either school level.
Primary intestinal lymphangiectasia successfully treated by segmental resections of small bowel.
Kim, Na Rae; Lee, Suk-Koo; Suh, Yeon-Lim
2009-10-01
Primary intestinal lymphangiectasia is a rare cause of protein-losing enteropathy and usually presents with intermittent diarrhea or malnutrition. Diagnosis depends largely on its pathologic condition demonstrating greatly dilated lymphatics mainly in the lamina propria of the mucosa. We report a case of primary intestinal lymphangiectasia, of the diffuse type, presenting with abdominal pain and voluminous diarrhea in a previously healthy 8-year-old boy. He had periumbilical pain for 3 months before presentation. He was managed by segmental bowel resections and end-to-end anastomoses. The histopathologic condition of the resected small intestine showed lymphatic dilation limited mainly to the subserosa and mesentery but was not prominent in the mucosa. Abdominal pain and diarrhea subsided postoperatively. The present case is the fourth report describing a response to operative resection.
Cura, Fernando A; Escudero, Alejandro Garcia; Berrocal, Daniel; Mendiz, Oscar; Trivi, Marcelo S; Fernandez, Juan; Palacios, Alejandro; Albertal, Mariano; Piraino, Ruben; Riccitelli, Miguel Angel; Gruberg, Luis; Ballarino, Miguel; Milei, Jose; Baeza, Ricardo; Thierer, Jorge; Grinfeld, Liliana; Krucoff, Mitchell; O'Neill, William; Belardi, Jorge
2007-02-01
Distal embolization may decrease myocardial reperfusion after primary percutaneous coronary intervention (PCI). Nonetheless, results of previous trials assessing the role of distal protection during primary PCI have been controversial. The Protection of Distal Embolization in High-Risk Patients with Acute ST-Segment Elevation Myocardial Infarction Trial (PREMIAR) was a prospective, randomized, controlled study designed to evaluate the role of filter-based distal protection during PCI in patients with acute ST-segment elevation myocardial infarction at high risk of embolic events (including only baseline Thrombolysis In Myocardial Infarction grade 0 to 2 flow). The primary end point was continuous monitoring of ST-segment resolution. Secondary end points included core laboratory analysis of angiographic myocardial blush, ejection fraction measured by cardiac ultrasound, and adverse cardiac events at 6 months. From a total of 194 enrolled patients, 140 subjects were randomized to PCI with or without embolic protection, and 54 were included in a registry arm due to the presence of angiographic exclusion criteria. Baseline characteristics were comparable between arms. The rate of complete ST-segment resolution (>or=70%) at 60 minutes was similar in patients treated with or without distal protection (61.2% vs 60.3%, respectively, p = 0.85). Angiographic myocardial blush (67% vs 70.7%, p = 0.73), in-hospital ejection fraction (47.4 +/- 9.9% vs 45.3 +/- 7.3%, p = 0.29), and combined end point of death, heart failure, or reinfarction at 6 months (14.3% vs 15.7%, p = 0.81) were consistently achieved in a similar proportion in the 2 groups. In conclusion, the use of filter-based distal protection is safe and effectively retrieves debris; however, such use does not translate into an improvement of myocardial reperfusion, left ventricular performance, or clinical outcomes.
Nikolić Heitzler, Vjeran; Babic, Zdravko; Milicic, Davor; Bergovec, Mijo; Raguz, Miroslav; Mirat, Jure; Strozzi, Maja; Plazonic, Zeljko; Giunio, Lovel; Steiner, Robert; Starcevic, Boris; Vukovic, Ivica
2010-05-01
The Republic of Croatia, with a gross domestic product per capita of US$11,554 in 2008, is an economically less-developed Western country. The goal of the present investigation was to prove that a well-organized primary percutaneous coronary intervention network in an economically less-developed country equalizes the prospects of all patients with acute ST-segment elevation myocardial infarction at a level comparable to that of more economically developed countries. We prospectively investigated 1,190 patients with acute ST-segment elevation myocardial infarction treated with primary PCI in 8 centers across Croatia (677 nontransferred and 513 transferred). The postprocedural Thrombolysis In Myocardial Infarction flow, in-hospital mortality, and incidence of major adverse cardiovascular events (ie, mortality, pectoral angina, restenosis, reinfarction, coronary artery bypass graft, and cerebrovascular accident rate) during 6 months of follow-up were compared between the nontransferred and transferred subgroups and in the subgroups of older patients, women, and those with cardiogenic shock. In all investigated patients, the average door-to-balloon time was 108 minutes, and the total ischemic time was 265 minutes. Postprocedural Thrombolysis In Myocardial Infarction 3 flow was established in 87.1% of the patients, and the in-hospital mortality rate was 4.4%. No statistically significant difference was found in the results of treatment between the transferred and nontransferred patients overall or in the subgroups of patients >75 years, women, and those with cardiogenic shock. In conclusion, the Croatian Primary Percutaneous Coronary Intervention Network has ensured treatment results of acute ST-segment elevation myocardial infarction comparable to those of randomized studies and registries of more economically developed countries. Copyright 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Park, Bumwoo; Furlan, Alessandro; Patil, Amol; Bae, Kyongtae T.
2010-03-01
Pulmonary embolism (PE) is a medical condition defined as the obstruction of pulmonary arteries by a blood clot, usually originating in the deep veins of the lower limbs. PE is a common but elusive illness that can cause significant disability and death if not promptly diagnosed and effectively treated. CT Pulmonary Angiography (CTPA) is the first line imaging study for the diagnosis of PE. While clinical prediction rules have been recently developed to associate short-term risks and stratify patients with acute PE, there is a dearth of objective biomarkers associated with the long-term prognosis of the disease. Clot (embolus) burden is a promising biomarker for the prognosis and recurrence of PE and can be quantified from CTPA images. However, to our knowledge, no study has reported a method for segmentation and measurement of clot from CTPA images. Thus, the purpose of this study was to develop a semi-automated method for segmentation and measurement of clot from CTPA images. Our method was based on Modified Seeded Region Growing (MSRG) algorithm which consisted of two steps: (1) the observer identifies a clot of interest on CTPA images and places a spherical seed over the clot; and (2) a region grows around the seed on the basis of a rolling-ball process that clusters the neighboring voxels whose CT attenuation values are within the range of the mean +/- two standard deviations of the initial seed voxels. The rollingball propagates iteratively until the clot is completely clustered and segmented. Our experimental results revealed that the performance of the MSRG was superior to that of the conventional SRG for segmenting clots, as evidenced by reduced degrees of over- or under-segmentation from adjacent anatomical structures. To assess the clinical value of clot burden for the prognosis of PE, we are currently applying the MSRG for the segmentation and volume measurement of clots from CTPA images that are acquired in a large cohort of patients with PE in an on-going NIH-sponsored clinical trial.
Sharma, R K; Singh, R; Bhardwaj, J K
2015-01-01
The ampullary segment of the mammalian oviduct provides suitable milieu for fertilization and development of zygote before implantation into uterus. It is, therefore, in the present study, the cyclic changes in the morphology of ampullary segment of goat oviduct were studied during follicular and luteal phases using scanning and transmission electron microscopy techniques. Topographical analysis revealed the presence of uniformly ciliated ampullary epithelia, concealing apical processes of non-ciliated cells along with bulbous secretory cells during follicular phase. The luteal phase was marked with decline in number of ciliated cells with increased occurrence of secretory cells. The ultrastructure analysis has demonstrated the presence of indented nuclear membrane, supranuclear cytoplasm, secretory granules, rough endoplasmic reticulum, large lipid droplets, apically located glycogen masses, oval shaped mitochondria in the secretory cells. The ciliated cells were characterized by the presence of elongated nuclei, abundant smooth endoplasmic reticulum, oval or spherical shaped mitochondria with crecentric cristae during follicular phase. However, in the luteal phase, secretory cells were possessing highly indented nucleus with diffused electron dense chromatin, hyaline nucleosol, increased number of lipid droplets. The ciliated cells had numerous fibrous granules and basal bodies. The parallel use of scanning and transmission electron microscopy techniques has enabled us to examine the cyclic and hormone dependent changes occurring in the topography and fine structure of epithelium of ampullary segment and its cells during different reproductive phases that will be great help in understanding major bottle neck that limits success rate in vitro fertilization and embryo transfer technology. © Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Loucaides, Constantinos A.
2018-01-01
This study examined seasonal differences in children's segmented-day physical activity (PA) and time engaged in sedentary activities. Seventy-three children wore a pedometer during winter and spring and completed a diary relating to their after-school sedentary activities and time playing outside. Children recorded higher steps in spring compared…
Effect of conductor geometry on source localization: Implications for epilepsy studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlitt, H.; Heller, L.; Best, E.
1994-07-01
We shall discuss the effects of conductor geometry on source localization for applications in epilepsy studies. The most popular conductor model for clinical MEG studies is a homogeneous sphere. However, several studies have indicated that a sphere is a poor model for the head when the sources are deep, as is the case for epileptic foci in the mesial temporal lobe. We believe that replacing the spherical model with a more realistic one in the inverse fitting procedure will improve the accuracy of localizing epileptic sources. In order to include a realistic head model in the inverse problem, we mustmore » first solve the forward problem for the realistic conductor geometry. We create a conductor geometry model from MR images, and then solve the forward problem via a boundary integral equation for the electric potential due to a specified primary source. One the electric potential is known, the magnetic field can be calculated directly. The most time-intensive part of the problem is generating the conductor model; fortunately, this needs to be done only once for each patient. It takes little time to change the primary current and calculate a new magnetic field for use in the inverse fitting procedure. We present the results of a series of computer simulations in which we investigate the localization accuracy due to replacing the spherical model with the realistic head model in the inverse fitting procedure. The data to be fit consist of a computer generated magnetic field due to a known current dipole in a realistic head model, with added noise. We compare the localization errors when this field is fit using a spherical model to the fit using a realistic head model. Using a spherical model is comparable to what is usually done when localizing epileptic sources in humans, where the conductor model used in the inverse fitting procedure does not correspond to the actual head.« less
Longitudinal Increase in Anisometropia in Older Adults
Haegerstrom-Portnoy, Gunilla; Schneck, Marilyn E.; Lott, Lori A.; Hewlett, Susan E.; Brabyn, John A.
2014-01-01
Purpose Anisometropia shows an exponential increase in prevalence with increasing age based on cross-sectional studies. The purpose of this study was to evaluate longitudinal changes in anisometropia in all refractive components in older observers and to assess the influence of early cataract development. Methods Refractive error was assessed at two time points separated by ~12 years in 118 older observers (ages 67.1 and 79.3 years at the two test times). Anisometropia defined as ≥1.00 D was calculated for all refractive components. The subjects had intact ocular lenses in both eyes throughout the study. Lens evaluations were performed at the second test using LOCS III. Results All refractive components approximately doubled in prevalence of anisometropia. Spherical equivalent anisometropia changed from 16.1% to 32.2%. Similar changes were found for spherical error (17% to 38.1%), primary astigmatism (7.6% to 17.8%) and oblique astigmatism (14.4% to 29.7%). Many who did not have anisometropia at the first visit subsequently developed anisometropia (for ex. 26.3% for spherical error and 22.9% for oblique cylinder). The onset of anisometropia occurred at all ages within the studied age range with no particular preference for any one age. A small number lost anisometropia over time. Individual comparisons of refractive error changes in the two eyes in combination with nuclear lens changes showed that early changes in nuclear sclerosis in the two eyes could account for a large proportion of anisometropia (~40%) but unequal hyperopic shift in the spherical component in the two eyes was the primary cause of the anisometropia. Conclusions Anisometropia is at least 10 times more common in the elderly than in children and anisometropia develops in all refractive components in the oldest observers. Clinicians need to be aware of this common condition that could lead to binocular vision problems and potentially cause falls in the elderly. PMID:24276578
Segmentation-free image processing and analysis of precipitate shapes in 2D and 3D
NASA Astrophysics Data System (ADS)
Bales, Ben; Pollock, Tresa; Petzold, Linda
2017-06-01
Segmentation based image analysis techniques are routinely employed for quantitative analysis of complex microstructures containing two or more phases. The primary advantage of these approaches is that spatial information on the distribution of phases is retained, enabling subjective judgements of the quality of the segmentation and subsequent analysis process. The downside is that computing micrograph segmentations with data from morphologically complex microstructures gathered with error-prone detectors is challenging and, if no special care is taken, the artifacts of the segmentation will make any subsequent analysis and conclusions uncertain. In this paper we demonstrate, using a two phase nickel-base superalloy microstructure as a model system, a new methodology for analysis of precipitate shapes using a segmentation-free approach based on the histogram of oriented gradients feature descriptor, a classic tool in image analysis. The benefits of this methodology for analysis of microstructure in two and three-dimensions are demonstrated.
Poly-Pattern Compressive Segmentation of ASTER Data for GIS
NASA Technical Reports Server (NTRS)
Myers, Wayne; Warner, Eric; Tutwiler, Richard
2007-01-01
Pattern-based segmentation of multi-band image data, such as ASTER, produces one-byte and two-byte approximate compressions. This is a dual segmentation consisting of nested coarser and finer level pattern mappings called poly-patterns. The coarser A-level version is structured for direct incorporation into geographic information systems in the manner of a raster map. GIs renderings of this A-level approximation are called pattern pictures which have the appearance of color enhanced images. The two-byte version consisting of thousands of B-level segments provides a capability for approximate restoration of the multi-band data in selected areas or entire scenes. Poly-patterns are especially useful for purposes of change detection and landscape analysis at multiple scales. The primary author has implemented the segmentation methodology in a public domain software suite.
Narrative Skills and Genre Knowledge: Ways of Telling in the Primary School Grades.
ERIC Educational Resources Information Center
Hicks, Deborah
1990-01-01
Primary school children, after viewing a silent film, were asked to narrate a segment of the film and recount its events both as a news story and as an embellished story. The results indicate that primary school children have only nascent ability to apply genre knowledge to school language tasks. (55 references) (Author/JL)
Bookwalter, Candice A; Venkatesh, Sudhakar K; Eaton, John E; Smyrk, Thomas D; Ehman, Richard L
2018-04-07
To determine correlation of liver stiffness measured by MR Elastography (MRE) with biliary abnormalities on MR Cholangiopancreatography (MRCP) and MRI parenchymal features in patients with primary sclerosing cholangitis (PSC). Fifty-five patients with PSC who underwent MRI of the liver with MRCP and MRE were retrospectively evaluated. Two board-certified abdominal radiologists in agreement reviewed the MRI, MRCP, and MRE images. The biliary tree was evaluated for stricture, dilatation, wall enhancement, and thickening at segmental duct, right main duct, left main duct, and common bile duct levels. Liver parenchyma features including signal intensity on T2W and DWI, and hyperenhancement in arterial, portal venous, and delayed phase were evaluated in nine Couinaud liver segments. Atrophy or hypertrophy of segments, cirrhotic morphology, varices, and splenomegaly were scored as present or absent. Regions of interest were placed in each of the nine segments on stiffness maps wherever available and liver stiffness (LS) was recorded. Mean segmental LS, right lobar (V-VIII), left lobar (I-III, and IVA, IVB), and global LS (average of all segments) were calculated. Spearman rank correlation analysis was performed for significant correlation. Features with significant correlation were then analyzed for significant differences in mean LS. Multiple regression analysis of MRI and MRCP features was performed for significant correlation with elevated LS. A total of 439/495 segments were evaluated and 56 segments not included in MRE slices were excluded for correlation analysis. Mean segmental LS correlated with the presence of strictures (r = 0.18, p < 0.001), T2W hyperintensity (r = 0.38, p < 0.001), DWI hyperintensity (r = 0.30, p < 0.001), and hyperenhancement of segment in all three phases. Mean LS of atrophic and hypertrophic segments were significantly higher than normal segments (7.07 ± 3.6 and 6.67 ± 3.26 vs. 5.1 ± 3.6 kPa, p < 0.001). In multiple regression analysis, only the presence of segmental strictures (p < 0.001), T2W hyperintensity (p = 0.01), and segmental hypertrophy (p < 0.001) were significantly associated with elevated segmental LS. Only left ductal stricture correlated with left lobe LS (r = 0.41, p = 0.018). Global LS correlated significantly with CBD stricture (r = 0.31, p = 0.02), number of segmental strictures (r = 0.28, p = 0.04), splenomegaly (r = 0.56, p < 0.001), and varices (r = 0.58, p < 0.001). In PSC, there is low but positive correlation between segmental LS and segmental duct strictures. Segments with increased LS show T2 hyperintensity, DWI hyperintensity, and post-contrast hyperenhancement. Global liver stiffness shows a moderate correlation with number of segmental strictures and significantly correlates with spleen stiffness, splenomegaly, and varices.
Hannibal, Roberta L; Price, Alivia L; Patel, Nipam H
2012-01-15
In arthropods, annelids and chordates, segmentation of the body axis encompasses both ectodermal and mesodermal derivatives. In vertebrates, trunk mesoderm segments autonomously and induces segmental arrangement of the ectoderm-derived nervous system. In contrast, in the arthropod Drosophila melanogaster, the ectoderm segments autonomously and mesoderm segmentation is at least partially dependent on the ectoderm. While segmentation has been proposed to be a feature of the common ancestor of vertebrates and arthropods, considering vertebrates and Drosophila alone, it is impossible to conclude whether the ancestral primary segmented tissue was the ectoderm or the mesoderm. Furthermore, much of Drosophila segmentation occurs before gastrulation and thus may not accurately represent the mechanisms of segmentation in all arthropods. To better understand the relationship between segmented germ layers in arthropods, we asked whether segmentation is an intrinsic property of the ectoderm and/or the mesoderm in the crustacean Parhyale hawaiensis by ablating either the ectoderm or the mesoderm and then assaying for segmentation in the remaining tissue layer. We found that the ectoderm segments autonomously. However, mesoderm segmentation requires at least a permissive signal from the ectoderm. Although mesodermal stem cells undergo normal rounds of division in the absence of ectoderm, they do not migrate properly in respect to migration direction and distance. In addition, their progeny neither divide nor express the mesoderm segmentation markers Ph-twist and Ph-Even-skipped. As segmentation is ectoderm-dependent in both Parhyale and holometabola insects, we hypothesize that segmentation is primarily a property of the ectoderm in pancrustacea. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Olczak, Gene; Fischer, David J.; Connelly, Mark; Wells, Conrad
2011-09-01
The James Webb Space Telescope (JWST) integration includes a center of curvature test on its 18 primary mirror segment assemblies (PMSAs). This important test is the only ground test that will demonstrate the ability to align all 18 PMSAs. Using a multi-wavelength interferometer (MWIF) integrated to the test bed telescope (TBT), a one-sixth scale model of the JWST, we verify our ability to align and phase the 18 PMSAs. In this paper we will discuss data analysis and test results when using the MWIF to align the segments of the TBT in preparation for alignment of the JWST.
Wang, Jie; Wong, Andus Wing-Kuen; Wang, Suiping; Chen, Hsuan-Chih
2017-07-19
It is widely acknowledged in Germanic languages that segments are the primary planning units at the phonological encoding stage of spoken word production. Mixed results, however, have been found in Chinese, and it is still unclear what roles syllables and segments play in planning Chinese spoken word production. In the current study, participants were asked to first prepare and later produce disyllabic Mandarin words upon picture prompts and a response cue while electroencephalogram (EEG) signals were recorded. Each two consecutive pictures implicitly formed a pair of prime and target, whose names shared the same word-initial atonal syllable or the same word-initial segments, or were unrelated in the control conditions. Only syllable repetition induced significant effects on event-related brain potentials (ERPs) after target onset: a widely distributed positivity in the 200- to 400-ms interval and an anterior positivity in the 400- to 600-ms interval. We interpret these to reflect syllable-size representations at the phonological encoding and phonetic encoding stages. Our results provide the first electrophysiological evidence for the distinct role of syllables in producing Mandarin spoken words, supporting a language specificity hypothesis about the primary phonological units in spoken word production.
Ryabykina, G V; Sozykin, A V; Dobrovolskaya, S V
2007-07-01
The aim of this study was to compare electrocardiogram (ECG)-12 dynamics depending on the methods of facilitated and primary angioplasty in patients with acute coronary syndrome. The ECG changes in 81 patients - 73 patients with acute myocardial infarction and 8 patients with unstable angina pectoris - were studied. The ECG analysis before reperfusion therapy and after angioplasty included: dynamics of summary elevation (Sigma ST+) and depression (Sigma ST-) of ST segment and changes of summary value of R waves (Sigma R) in 12 leads. The results were estimated with consideration for the length of the period from the beginning of pain syndrome till treatment and topics of the infraction-related artery. According to our data, there was no difference between facilitated and primary transluminal coronary angioplasty in their effect on focal myocardial variation dynamics and the size of peri-infarction zone. A reliable decrease in elevation and depression of ST segment was observed in reperfusion therapy not later than 6 hours after the beginning of pain syndrome. When reperfusion therapy is begun later, dynamics of summary values of ST segment elevation and depression before and after treatment are not reliable.
Optimal wavefront control for adaptive segmented mirrors
NASA Technical Reports Server (NTRS)
Downie, John D.; Goodman, Joseph W.
1989-01-01
A ground-based astronomical telescope with a segmented primary mirror will suffer image-degrading wavefront aberrations from at least two sources: (1) atmospheric turbulence and (2) segment misalignment or figure errors of the mirror itself. This paper describes the derivation of a mirror control feedback matrix that assumes the presence of both types of aberration and is optimum in the sense that it minimizes the mean-squared residual wavefront error. Assumptions of the statistical nature of the wavefront measurement errors, atmospheric phase aberrations, and segment misalignment errors are made in the process of derivation. Examples of the degree of correlation are presented for three different types of wavefront measurement data and compared to results of simple corrections.
Diffusive tunneling for alleviating Knudsen-layer reactivity reduction under hydrodynamic mix
NASA Astrophysics Data System (ADS)
Tang, Xianzhu; McDevitt, Chris; Guo, Zehua
2017-10-01
Hydrodynamic mix will produce small features for intermixed deuterium-tritium fuel and inert pusher materials. The geometrical characteristics of the mix feature have a large impact on Knudsen layer yield reduction. We considered two features. One is planar structure, and the other is fuel cells segmented by inert pusher material which can be represented by a spherical DT bubble enclosed by a pusher shell. The truly 3D fuel feature, the spherical bubble, has the largest degree of yield reduction, due to fast ions being lost in all directions. The planar fuel structure, which can be regarded as 1D features, has modest amount of potential for yield degradation. While the increasing yield reduction with increasing Knudsen number of the fuel region is straightforwardly anticipated, we also show, by a combination of direct simulation and simple model, that once the pusher materials is stretched sufficiently thin by hydrodynamic mix, the fast fuel ions diffusively tunnel through them with minimal energy loss, so the Knudsen layer yield reduction becomes alleviated. This yield recovery can occur in a chunk-mixed plasma, way before the far more stringent, asymptotic limit of an atomically homogenized fuel and pusher assembly. Work supported by LANL LDRD program.
Formation of a cavitation cluster in the vicinity of a quasi-empty rupture
NASA Astrophysics Data System (ADS)
Bol'shakova, E. S.; Kedrinskiy, V. K.
2017-09-01
The presentation deals with one of the experimental and numerical models of a quasi-empty rupture in the magma melt. This rupture is formed in the liquid layer of a distilled cavitating fluid under shock loading within the framework of the problem formulation with a small electromagnetic hydrodynamic shock tube. It is demonstrated that the rupture is shaped as a spherical segment, which retains its topology during the entire process of its evolution and collapsing. The dynamic behavior of the quasi-empty rupture is analyzed, and the growth of cavitating nuclei in the form of the boundary layer near the entire rupture interface is found. It is shown that rupture implosion is accompanied by the transformation of the bubble boundary layer to a cavitating cluster, which takes the form of a ring-shaped vortex floating upward to the free surface of the liquid layer. A p-κ mathematical model is formulated, and calculations are performed to investigate the implosion of a quasi-empty spherical cavity in the cavitating liquid, generation of a shock wave by this cavity, and dynamics of the bubble density growth in the cavitating cluster by five orders of magnitude.
Segment phasing experiments on the High Order Test bench
NASA Astrophysics Data System (ADS)
Aller-Carpentier, E.; Kasper, M.; Martinez, P.
The segmented primary mirror of the E-ELT imposes particular requirements on an Extreme Adaptive Optics (XAO) system. At present, there are already several AO systems working on segmented telescopes but the achieved performances are too low to draw conclusions for XAO systems aiming at some 90% Strehl ratio in the NIR. On other hand, several analytical studies and simulations were done, but laboratory studies are required to confirm the corrections expected. The goal of the present study is to determina the capability of XAO systems to deal with segmentation piston errors. In particular, the effects on the AO performance and the ability of the AO system to correct the segmentation piston errors were studied. The experiments were carried out on the High Order Test Bench at ESO (Munich) using a Shack-Hartmann wave front sensor and under most realistic conditions with phase screens simulating atmospheric turbulence and segmentation piston errors. Segment geometry was chosen such that about 6 actuators of the XAO DM cover one segment representing the design of EPICS at the EELT.
1999-04-20
NASA's Space Optics Manufacturing Technology Center has been working to expand our view of the universe via sophisticated new telescopes. The Optics Center's goal is to develop low-cost, advanced space optics technologies for the NASA program in the 21st century, including the long-term goal of imaging Earth-like planets in distant solar systems. A segmented array of mirrors was designed by the Space Optics Manufacturing Technology Center for the solar concentrator test stand at the Marshall Space Flight Center (MSFC) for powering solar thermal propulsion engines. Each hexagon mirror has a spherical surface to approximate a parabolic concentrator when combined into the entire 18-foot diameter array. The aluminum mirrors were polished with a diamond turning machine that creates a glass-like reflective finish on metal. The precision fabrication machinery at the Space Optics Manufacturing Technology Center at MSFC can polish specialized optical elements to a world class quality of smoothness. This image shows optics physicist, Vince Huegele, examining one of the 144-segment hexagonal mirrors of the 18-foot diameter array at the MSFC solar concentrator test stand.
1999-04-20
NASA's Space Optics Manufacturing Technology Center has been working to expand our view of the universe via sophisticated new telescopes. The Optics Center's goal is to develop low-cost, advanced space optics technologies for the NASA program in the 21st century, including the long-term goal of imaging Earth-like planets in distant solar systems. A segmented array of mirrors was designed by the Space Optics Manufacturing Technology Center for solar the concentrator test stand at the Marshall Space Flight Center (MSFC) for powering solar thermal propulsion engines. Each hexagon mirror has a spherical surface to approximate a parabolic concentrator when combined into the entire 18-foot diameter array. The aluminum mirrors were polished with a diamond turning machine, that creates a glass-like reflective finish on metal. The precision fabrication machinery at the Space Optics Manufacturing Technology Center at MSFC can polish specialized optical elements to a world class quality of smoothness. This image shows optics physicist, Vince Huegele, examining one of the 144-segment hexagonal mirrors of the 18-foot diameter array at the MSFC solar concentrator test stand.
Isomap transform for segmenting human body shapes.
Cerveri, P; Sarro, K J; Marchente, M; Barros, R M L
2011-09-01
Segmentation of the 3D human body is a very challenging problem in applications exploiting volume capture data. Direct clustering in the Euclidean space is usually complex or even unsolvable. This paper presents an original method based on the Isomap (isometric feature mapping) transform of the volume data-set. The 3D articulated posture is mapped by Isomap in the pose of Da Vinci's Vitruvian man. The limbs are unrolled from each other and separated from the trunk and pelvis, and the topology of the human body shape is recovered. In such a configuration, Hoshen-Kopelman clustering applied to concentric spherical shells is used to automatically group points into the labelled principal curves. Shepard interpolation is utilised to back-map points of the principal curves into the original volume space. The experimental results performed on many different postures have proved the validity of the proposed method. Reliability of less than 2 cm and 3° in the location of the joint centres and direction axes of rotations has been obtained, respectively, which qualifies this procedure as a potential tool for markerless motion analysis.
Yu, Byong Yong; Kwak, Seung-Yeop
2011-10-21
Based on a self-assembly strategy, spherical mesoporous cobalt and nickel ferrite nanocrystal clusters with a large surface area and narrow size distribution were successfully synthesized for the first time via a template-free solvothermal process in ethylene glycol and subsequent heat treatment. In this work, the mesopores in the ferrite clusters were derived mainly from interior voids between aggregated primary nanoparticles (with crystallite size of less than 7 nm) and disordered particle packing domains. The concentration of sodium acetate is shown herein to play a crucial role in the formation of mesoporous ferrite spherical clusters. These ferrite clusters were characterized in detail using wide-angle X-ray diffraction, thermogravimetric-differential thermal analysis, (57)Fe Mössbauer spectroscopy, X-ray photoelectron spectroscopy, field-emission scanning electron microscopy, standard and high-resolution transmission electron microscopy, and other techniques. The results confirmed the formation of both pure-phase ferrite clusters with highly crystalline spinel structure, uniform size (about 160 nm) and spherical morphology, and worm-like mesopore structures. The BET specific surface areas and mean pore sizes of the mesoporous Co and Ni-ferrite clusters were as high as 160 m(2) g(-1) and 182 m(2) g(-1), and 7.91 nm and 6.87 nm, respectively. A model for the formation of the spherical clusters in our system is proposed on the basis of the results. The magnetic properties of both samples were investigated at 300 K, and it was found that these materials are superparamagnetic. This journal is © The Royal Society of Chemistry 2011
Multilayer X-ray imaging systems
NASA Astrophysics Data System (ADS)
Shealy, D. L.; Hoover, R. B.; Gabardi, D. R.
1986-01-01
An assessment of the imaging properties of multilayer X-ray imaging systems with spherical surfaces has been made. A ray trace analysis was performed to investigate the effects of using spherical substrates (rather than the conventional paraboloidal/hyperboloidal contours) for doubly reflecting Cassegrain telescopes. These investigations were carried out for mirrors designed to operate at selected soft X-ray/XUV wavelengths that are of significance for studies of the solar corona/transition region from the Stanford/MSFC Rocket X-Ray Telescope. The effects of changes in separation of the primary and secondary elements were also investigated. These theoretical results are presented as well as the results of ray trace studies to establish the resolution and vignetting effects as a function of field angle and system parameters.
Bolognese, Leonardo; Falsini, Giovanni; Schwenke, Carsten; Grotti, Simone; Limbruno, Ugo; Liistro, Francesco; Carrera, Arcangelo; Angioli, Paolo; Picchi, Andrea; Ducci, Kenneth; Pierli, Carlo
2012-01-01
Conflicting data have been reported on the effects of low-osmolar and iso-osmolar contrast media on contrast-induced acute kidney injury (CI-AKI). In particular, no clinical trial has yet focused on the effect of contemporary contrast media on CI-AKI, epicardial flow, and microcirculatory function in patients with ST-segment elevation acute myocardial infarction who undergo primary percutaneous coronary intervention. The Contrast Media and Nephrotoxicity Following Coronary Revascularization by Angioplasty for Acute Myocardial Infarction (CONTRAST-AMI) trial is a prospective, randomized, single-blind, parallel-group, noninferiority study aiming to evaluate the effects of the low-osmolar contrast medium iopromide compared to the iso-osmolar agent iodixanol on CI-AKI and tissue-level perfusion in patients with ST-segment elevation acute myocardial infarction. Four hundred seventy-five consecutive, unselected patients who underwent primary percutaneous coronary intervention were randomized to iopromide (n = 239) or iodixanol (n = 236). All patients received high-dose N-acetylcysteine and hydration. The primary end point was the proportion of patients with serum creatinine (sCr) increases ≥25% from baseline to 72 hours. Secondary end points were Thrombolysis In Myocardial Infarction (TIMI) myocardial perfusion grade, increase in sCr ≥50%, increase in sCr ≥0.5 or ≥1 mg/dl, and 1-month major adverse cardiac events. The primary end point occurred in 10% of the iopromide group and in 13% of the iodixanol group (95% confidence interval -9% to 3%, p for noninferiority = 0.0002). A TIMI myocardial perfusion grade of 0 or 1 was present in 14% of patients in the 2 groups. No differences between the 2 groups were found in any of the secondary analyses of sCr increase. No significant difference in 1-month major adverse cardiac events was found (8% vs 6%, p = 0.37). In conclusion, in a population of unselected patients with ST-segment elevation acute myocardial infarction who underwent primary percutaneous coronary intervention, iopromide was not inferior to iodixanol in the occurrence of CI-AKI; no significant differences were found in terms of tissue-level reperfusion and major adverse cardiac events between the 2 contrast agents. Copyright © 2012 Elsevier Inc. All rights reserved.
Vura, Nandagopal; Gaddipati, Rajasekhar; Palla, Yudhistar; Kumar, Pranay
2018-04-01
The protruding and deviated premaxilla in bilateral complete cleft lip and palate (BCL/P) patients causes a perplexing problem in achieving a tension-free primary lip closure. An innovative noninvasive active intraoral Fixed Pre-Surgical Cleft Orthopedic (FPSCO) appliance is presented that has enabled to successfully reposition the premaxillary segment to a more favorable position prior to the surgical repair in 4 BCL/P patients, who reported late for treatment with a mean age of 18 ± 3 months. All the patients had at least 1 deciduous tooth erupted in 3 cleft segments, 1 premaxilla (PM), and 2 lateral maxillary (LM) segments. This innovative approach is a noninvasive method of getting the cleft segments closer prior to chelioplasty, where conventional presurgical nasoalveolar molding (PNAM) is not possible, which needs to be done early in life as it requires circulating maternal estrogen levels to achieve results preferably possible in patients younger than 3 to 6 months. Bonding to erupted teeth with glass ionomer cement was implemented to secure the appliance. Nickel-titanium (Ni-Ti) closed-coil springs were used that delivered continuous forces of 150 g/5 oz per side to retract the premaxillary segment. The mean active period of treatment time was 3.5 ± 1.6 months and the retention period was 1.2 ± 0.6 months, following which cheiloplasty was performed.
Global Radius of Curvature Estimation and Control for the Hobby-Eberly Telescope
NASA Technical Reports Server (NTRS)
Rakoczy, John; Hall, Drew; Howard, Ricky; Ly, William; Weir, John; Montgomery, Edward; Brantley, Lott W. (Technical Monitor)
2002-01-01
A system, which estimates the global radius of curvature (GroC) and corrects for changes in GroC on a segmented primary mirror has been developed for and verified on McDonald Observatory's Hobby Eberly Telescope (HET). The GroC estimation and control system utilizes HET's primary mirror control (PMC) system and the Segment Alignment Maintenance System (SAMS), an inductive edge sensor system. A special set of boundary conditions is applied to the derivation of the optimal edge match control. The special boundary conditions allow the further derivation of an observer, which enables estimation and control of the Groc mode to within HET's specification. The magnitude of the GroC mode can then be controlled despite the inability of the SAMS edge sensor system, by itself, to observe or control the GroC mode. The observer can be extended to any segmented mirror telescope. It will be shown that the observer improves with accuracy as the number of segments increases. This paper presents the mathematical theory of the observer. Simulation results will demonstrate the inherent accuracy and robustness of the system. Performance verification data from the HET will be presented.
Mosher, Andrea A; Rainey, Kelly J; Bolstad, Seunghwa S; Lye, Stephen J; Mitchell, Bryan F; Olson, David M; Wood, Stephen L; Slater, Donna M
2013-01-01
The development of the in vitro cell culture model has greatly facilitated the ability to study gene expression and regulation within human tissues. Within the human uterus, the upper (fundal) segment and the lower segment may provide distinct functions throughout pregnancy and during labour. We have established primary cultured human myometrial cells, isolated from both upper and lower segment regions of the pregnant human uterus, and validated them for the purpose of studying human pregnancy and labour. The specific objectives of this study were to monitor the viability and characterize the expression profile using selected cellular, contractile and pregnancy associated markers in the primary cultured human myometrial cells. Labour has been described as an inflammatory process; therefore, the ability of these cells to respond to an inflammatory stimulus was also investigated. Myometrial cells isolated from paired upper segment (US) and lower segment (LS) biopsies, obtained from women undergoing Caesarean section deliveries at term prior to the onset of labour, were used to identify expression of; α smooth muscle actin, calponin, caldesmon, connexin 43, cyclo-oxygenase-2 (COX-2), oxytocin receptor, tropomyosin and vimentin, by RT-PCR and/or immunocytochemistry. Interleukin (IL)-1β was used to treat cells, subsequently expression of COX-2 mRNA and release of interleukin-8 (CXCL8), were measured. ANOVA followed by Bonferroni's multiple comparisons test was performed. We demonstrate that US and LS human myometrial cells stably express all markers examined to at least passage ten (p10). Connexin 43, COX-2 and vimentin mRNA expression were significantly higher in LS cells compared to US cells. Both cell populations respond to IL-1β, demonstrated by a robust release of CXCL8 and increased expression of COX-2 mRNA from passage one (p1) through to p10. Isolated primary myometrial cells maintain expression of smooth muscle and pregnancy-associated markers and retain their ability to respond to an inflammatory stimulus. These distinct myometrial cell models will provide a useful tool to investigate mechanisms underlying the process of human labour and the concept of functional regionalization of the pregnant uterus.
LDR structural experiment definition
NASA Technical Reports Server (NTRS)
Russell, Richard A.; Gates, Richard M.
1988-01-01
A study was performed to develop the definition of a structural flight experiment for a large precision segmented reflector that would utilize the Space Station. The objective of the study was to use the Large Deployable Reflector (LDR) baseline configuration for focusing on experiment definition activity which would identify the Space Station accommodation requirements and interface constraints. Results of the study defined three Space Station based experiments to demonstrate the technologies needed for an LDR type structure. The basic experiment configurations are the same as the JPL baseline except that the primary mirror truss is 10 meters in diameter instead of 20. The primary objectives of the first experiment are to construct the primary mirror support truss and to determine its structural and thermal characteristics. Addition of the optical bench, thermal shield and primary mirror segments and alignment of the optical components occur on the second experiment. The structure will then be moved to the payload pointing system for pointing, optical control and scientific optical measurement for the third experiment.
NASA Astrophysics Data System (ADS)
Liao, Luhua; Li, Lemin; Wang, Sheng
2006-12-01
We investigate the protection approach for dynamic multicast traffic under shared risk link group (SRLG) constraints in meshed wavelength-division-multiplexing optical networks. We present a shared protection algorithm called dynamic segment shared protection for multicast traffic (DSSPM), which can dynamically adjust the link cost according to the current network state and can establish a primary light-tree as well as corresponding SRLG-disjoint backup segments for a dependable multicast connection. A backup segment can efficiently share the wavelength capacity of its working tree and the common resources of other backup segments based on SRLG-disjoint constraints. The simulation results show that DSSPM not only can protect the multicast sessions against a single-SRLG breakdown, but can make better use of the wavelength resources and also lower the network blocking probability.
NASA Astrophysics Data System (ADS)
Minami, K.; Saito, Y.; Kai, H.; Shirota, K.; Yada, K.
2009-09-01
We have newly developed an open type fine-focus X-ray tube "TX-510" to realize a spatial resolution of 50nm and to radiate low energy characteristic X-rays for giving high absorption contrast to images of microscopic organisms. The "TX-510" employs a ZrO/W(100) Schottky emitter and an "In-Lens Field Emission Gun". The key points of the improvements are (1) reduced spherical aberration coefficient of magnetic objective lens, (2) easy and accurate focusing, (3) newly designed astigmatism compensator, (4) segmented thin film target for interchanging the target materials by electron beam shift and (5) fluorescent X-ray analysis system.
The limits of boundaries: unpacking localization and cognitive mapping relative to a boundary.
Zhou, Ruojing; Mou, Weimin
2018-05-01
Previous research (Zhou, Mou, Journal of Experimental Psychology: Learning, Memory and Cognition 42(8):1316-1323, 2016) showed that learning individual locations relative to a single landmark, compared to learning relative to a boundary, led to more accurate inferences of inter-object spatial relations (cognitive mapping of multiple locations). Following our past findings, the current study investigated whether the larger number of reference points provided by a homogeneous circular boundary, as well as less accessible knowledge of direct spatial relations among the multiple reference points, would lead to less effective cognitive mapping relative to the boundary. Accordingly, we manipulated (a) the number of primary reference points (one segment drawn from a circular boundary, four such segments, vs. the complete boundary) available when participants were localizing four objects sequentially (Experiment 1) and (b) the extendedness of each of the four segments (Experiment 2). The results showed that cognitive mapping was the least accurate in the whole boundary condition. However, expanding each of the four segments did not affect the accuracy of cognitive mapping until the four were connected to form a continuous boundary. These findings indicate that when encoding locations relative to a homogeneous boundary, participants segmented the boundary into differentiated pieces and subsequently chose the most informative local part (i.e., the segment closest in distance to one location) as the primary reference point for a particular location. During this process, direct spatial relations among the reference points were likely not attended to. These findings suggest that people might encode and represent bounded space in a fragmented fashion when localizing within a homogeneous boundary.
Spatial limitations of fast temporal segmentation are best modeled by V1 receptive fields.
Goodbourn, Patrick T; Forte, Jason D
2013-11-22
The fine temporal structure of events influences the spatial grouping and segmentation of visual-scene elements. Although adjacent regions flickering asynchronously at high temporal frequencies appear identical, the visual system signals a boundary between them. These "phantom contours" disappear when the gap between regions exceeds a critical value (g(max)). We used g(max) as an index of neuronal receptive-field size to compare with known receptive-field data from along the visual pathway and thus infer the location of the mechanism responsible for fast temporal segmentation. Observers viewed a circular stimulus reversing in luminance contrast at 20 Hz for 500 ms. A gap of constant retinal eccentricity segmented each stimulus quadrant; on each trial, participants identified a target quadrant containing counterphasing inner and outer segments. Through varying the gap width, g(max) was determined at a range of retinal eccentricities. We found that g(max) increased from 0.3° to 0.8° for eccentricities from 2° to 12°. These values correspond to receptive-field diameters of neurons in primary visual cortex that have been reported in single-cell and fMRI studies and are consistent with the spatial limitations of motion detection. In a further experiment, we found that modulation sensitivity depended critically on the length of the contour and could be predicted by a simple model of spatial summation in early cortical neurons. The results suggest that temporal segmentation is achieved by neurons at the earliest cortical stages of visual processing, most likely in primary visual cortex.
NASA Astrophysics Data System (ADS)
Beach, David A.
2001-12-01
Design variants of a recently developed optical imaging system have been computed for the thermal infrared spectral bands, which offer some advantages for long-range surveillance and astronomy. Only the spherical primary mirror has the full pupil diameter, all other components being sub-diameter, so scaling is possible up to relatively large pupils. Low-cost fabrication is enabled by the prevalence of spherical optical surfaces. Both MWIR and LWIR spectral transmissions are enabled by the choice of corrector materials, the examples given employing germanium and sapphire for 3.5 - 5.5 micrometers and germanium and zinc selenide for 3.5 - 5.5 micrometers and 8 - 12 micrometers passbands. Diffraction at these wavelengths is the main contributor to resolution constraints, so high numerical aperture values are preferred to enable a better match of blur spot diameter to generally available pixel dimensions. The systems described can routinely be designed to have speeds of f/0.8 or faster, while maintaining diffraction-limited performance over useful angular fields. Because the new design system employs a relayed catadioptric, it is possible to make the aperture stop of the system coincident with the window of the detector cryostat, enabling precise radiometric geometry. The central obscuration provides a convenient location for a calibration source, and both this and a mask for secondary spider supports can be included within the detector cold screen structure. Dual-band operation could be enabled by inclusion of a spectral beam splitter prior to a dual relay/imager system.
Equal-Curvature X-ray Telescope Designs for Constellation-X Mission
NASA Technical Reports Server (NTRS)
Saha, Timo T.; Content, David A.; Zhang, William W.
2003-01-01
We study grazing incidence Equal-Curvature telescope designs for the Constellation-X mission. These telescopes have nearly spherical axial surfaces. The telescopes are designed so that the axial curvature is the same on the primary and secondary. The optical performance of these telescopes is for all practical purposes identical to the equivalent Wolter telescopes.
Manufacture of a 1.7m prototype of the GMT primary mirror segments
NASA Astrophysics Data System (ADS)
Martin, H. M.; Burge, J. H.; Miller, S. M.; Smith, B. K.; Zehnder, R.; Zhao, C.
2006-06-01
We have nearly completed the manufacture of a 1.7 m off-axis mirror as part of the technology development for the Giant Magellan Telescope. The mirror is an off-axis section of a 5.3 m f/0.73 parent paraboloid, making it roughly a 1:5 model of the outer 8.4 m GMT segment. The 1.7 m mirror will be the primary mirror of the New Solar Telescope at Big Bear Solar Observatory. It has a 2.7 mm peak-to-valley departure from the best-fit sphere, presenting a serious challenge in terms of both polishing and measurement. The mirror was polished with a stressed lap, which bends actively to match the local curvature at each point on the mirror surface, and works for asymmetric mirrors as well as symmetric aspheres. It was measured using a hybrid reflective-diffractive null corrector to compensate for the mirror's asphericity. Both techniques will be applied in scaled-up versions to the GMT segments.
Haeck, Joost D E; Verouden, Niels J W; Kuijt, Wichert J; Koch, Karel T; Van Straalen, Jan P; Fischer, Johan; Groenink, Maarten; Bilodeau, Luc; Tijssen, Jan G P; Krucoff, Mitchell W; De Winter, Robbert J
2010-04-15
The purpose of the present study was to determine the prognostic value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP), among other serum biomarkers, on cardiac magnetic resonance (CMR) imaging parameters of cardiac function and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. We measured NT-pro-BNP, cardiac troponin T, creatinine kinase-MB fraction, high-sensitivity C-reactive protein, and creatinine on the patients' arrival at the catheterization laboratory in 206 patients with ST-segment elevation myocardial infarction. The NT-pro-BNP levels were divided into quartiles and correlated with left ventricular function and infarct size measured by CMR imaging at 4 to 6 months. Compared to the lower quartiles, patients with nonanterior wall myocardial infarction in the highest quartile of NT-pro-BNP (> or = 260 pg/ml) more often had a greater left ventricular end-systolic volume (68 vs 39 ml/m(2), p <0.001), a lower left ventricular ejection fraction (42% vs 54%, p <0.001), a larger infarct size (9 vs 4 g/m(2), p = 0.002), and a larger number of transmural segments (11% of segments vs 3% of segments, p <0.001). Multivariate analysis revealed that a NT-pro-BNP level of > or = 260 pg/ml was the strongest independent predictor of left ventricular ejection fraction in patients with nonanterior wall myocardial infarction compared to the other serum biomarkers (beta = -5.8; p = 0.019). In conclusion, in patients with nonanterior wall myocardial infarction undergoing primary percutaneous coronary intervention, an admission NT-pro-BNP level of > or = 260 pg/ml was a strong, independent predictor of left ventricular function assessed by CMR imaging at follow-up. Our findings suggest that NT-pro-BNP, a widely available biomarker, might be helpful in the early risk stratification of patients with nonanterior wall myocardial infarction. Copyright 2010 Elsevier Inc. All rights reserved.
Social marketing, stages of change, and public health smoking interventions.
Diehr, Paula; Hannon, Peggy; Pizacani, Barbara; Forehand, Mark; Meischke, Hendrika; Curry, Susan; Martin, Diane P; Weaver, Marcia R; Harris, Jeffrey
2011-04-01
As a "thought experiment," the authors used a modified stages of change model for smoking to define homogeneous segments within various hypothetical populations. The authors then estimated the population effect of public health interventions that targeted the different segments. Under most assumptions, interventions that emphasized primary and secondary prevention, by targeting the Never Smoker, Maintenance, or Action segments, resulted in the highest nonsmoking life expectancy. This result is consistent with both social marketing and public health principles. Although the best thing for an individual smoker is to stop smoking, the greatest public health benefit is achieved by interventions that target nonsmokers.
Constructing a dispersed fringe sensor prototype for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Frostig, Danielle; McLeod, Brian; AGWS Team
2018-01-01
The Giant Magellan Telescope (GMT) will be the world’s largest telescope upon completion. The GMT employs seven 8 m primary mirror segments and seven 1 m secondary mirror segments. One challenge of the GMT is keeping the seven pairs of mirror segments on the GMT in phase. In this project, we developed and began assembly on a design for a dispersed fringe sensor prototype consisting of an optical and basic mechanical layout. The prototype design will be tested on the Magellan Clay Telescope as an experiment for future phasing methods to be used on the GMT.
A dispersed fringe sensor prototype for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Frostig, Danielle; McLeod, Brian A.; Kopon, Derek
2017-01-01
The Giant Magellan Telescope (GMT) will employ seven 8.4m primary mirror segments and seven 1m secondary mirror segments to achieve the diffraction limit of a 25.4m aperture. One challenge of the GMT is keeping the seven pairs of mirror segments in phase. We present a conceptual opto mechanical design for a prototype dispersed fringe sensor. The prototype, which operates at J-band and incorporates an infrared avalanche photodiode array, will be deployed on the Magellan Clay Telescope to verify the sensitivity and accuracy of the planned GMT phasing sensor.
Initialisation of 3D level set for hippocampus segmentation from volumetric brain MR images
NASA Astrophysics Data System (ADS)
Hajiesmaeili, Maryam; Dehmeshki, Jamshid; Bagheri Nakhjavanlo, Bashir; Ellis, Tim
2014-04-01
Shrinkage of the hippocampus is a primary biomarker for Alzheimer's disease and can be measured through accurate segmentation of brain MR images. The paper will describe the problem of initialisation of a 3D level set algorithm for hippocampus segmentation that must cope with the some challenging characteristics, such as small size, wide range of intensities, narrow width, and shape variation. In addition, MR images require bias correction, to account for additional inhomogeneity associated with the scanner technology. Due to these inhomogeneities, using a single initialisation seed region inside the hippocampus is prone to failure. Alternative initialisation strategies are explored, such as using multiple initialisations in different sections (such as the head, body and tail) of the hippocampus. The Dice metric is used to validate our segmentation results with respect to ground truth for a dataset of 25 MR images. Experimental results indicate significant improvement in segmentation performance using the multiple initialisations techniques, yielding more accurate segmentation results for the hippocampus.
Metrology requirements for the serial production of ELT primary mirror segments
NASA Astrophysics Data System (ADS)
Rees, Paul C. T.; Gray, Caroline
2015-08-01
The manufacture of the next generation of large astronomical telescopes, the extremely large telescopes (ELT), requires the rapid manufacture of greater than 500 1.44m hexagonal segments for the primary mirror of each telescope. Both leading projects, the Thirty Meter Telescope (TMT) and the European Extremely Large Telescope (E-ELT), have set highly demanding technical requirements for each fabricated segment. These technical requirements, when combined with the anticipated construction schedule for each telescope, suggest that more than one optical fabricator will be involved in the delivery of the primary mirror segments in order to meet the project schedule. For one supplier, the technical specification is challenging and requires highly consistent control of metrology in close coordination with the polishing technologies used in order to optimize production rates. For production using multiple suppliers, however the supply chain is structured, consistent control of metrology along the supply chain will be required. This requires a broader pattern of independent verification than is the case of a single supplier. This paper outlines the metrology requirements for a single supplier throughout all stages of the fabrication process. We identify and outline those areas where metrology accuracy and duration have a significant impact on production efficiency. We use the challenging ESO E-ELT technical specification as an example of our treatment, including actual process data. We further develop this model for the case of a supply chain consisting of multiple suppliers. Here, we emphasize the need to control metrology throughout the supply chain in order to optimize net production efficiency.
Holló, Gábor; Shu-Wei, Hsu; Naghizadeh, Farzaneh
2016-06-01
To compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue-OCT) for ganglion cell complex (GCC) and retinal nerve fiber layer thickness (RNFLT) image segmentation and detection of glaucoma in high myopia. RNFLT and GCC scans were acquired with software version 6.3 of the RTVue-OCT on 51 highly myopic eyes (spherical refractive error ≤-6.0 D) of 51 patients, and were analyzed with both the software versions. Twenty-two eyes were nonglaucomatous, 13 were ocular hypertensive and 16 eyes had glaucoma. No difference was seen for any RNFLT, and average GCC parameter between the software versions (paired t test, P≥0.084). Global loss volume was significantly lower (more normal) with version 6.12 than with version 6.3 (Wilcoxon signed-rank test, P<0.001). The percentage agreement (κ) between the clinical (normal and ocular hypertensive vs. glaucoma) and the software-provided classifications (normal and borderline vs. outside normal limits) were 0.3219 and 0.4442 for average RNFLT, and 0.2926 and 0.4977 for average GCC with versions 1 and 2, respectively (McNemar symmetry test, P≥0.289). No difference in average RNFLT and GCC classification (McNemar symmetry test, P≥0.727) and the number of eyes with at least 1 segmentation error (P≥0.109) was found between the software versions, respectively. Although GCC segmentation was improved with software version 6.12 compared with the current version in highly myopic eyes, this did not result in a significant change of the average RNFLT and GCC values, and did not significantly improve the software-provided classification for glaucoma.
2017-05-19
Vijay Singh, Martin Tchernookov, Rebecca Butterfield, Ilya Nemenman, Rongrong Ji. Director Field Model of the Primary Visual Cortex for Contour...FTE Equivalent: Total Number: DISCIPLINE Vijay Singh 40 Physics 0.40 1 PERCENT_SUPPORTEDNAME FTE Equivalent: Total Number: Martin Tchernookov 0.20
Casson, Robert J; Kahawita, Shyalle; Kong, Aimee; Muecke, James; Sisaleumsak, Siphetthavong; Visonnavong, Vithoune
2012-10-01
Vientiane Province is an urbanizing region in Southeast Asia. We aimed to determine the prevalence of refractive error and visual impairment in primary school-aged children in this region. Prospective, cross-sectional survey. A total of 2899 schoolchildren from Vientiane Province, Lao People's Democratic Republic (Lao PDR). Ten districts from Vientiane were randomly selected and 2 primary schools were randomly selected from each district. All children aged 6 to 11 years at selected schools were eligible to participate. The examination included visual acuity (VA) testing, cycloplegic retinoscopy with subjective refinement if indicated, ocular motility testing, and anterior segment and fundus examinations in visually impaired children. Cycloplegic refraction and VA. There was an estimated total of 3330 children who were eligible to participate, and data were recorded from 2899 (87%) of these children. Complete refractive data were available on 2842 children (85% of eligible population). The mean spherical equivalent (SE) in the right eyes was +0.60 diopter (D) (95% confidence interval [CI], 0.49-0.72), and the mean SE in the left eyes was +0.59 (95% CI, 0.50-0.68). The prevalence of hyperopia was 2.8% (95% CI, 1.9-3.7; 88 subjects), and the prevalence of myopia was 0.8% (95% CI, 0.3-1.4; 24 subjects). The majority of children (98%; 95% CI, 97.0-99.0) had normal unaided binocular VA (at least 20/32 in their better eye). The overall prevalence of any visual impairment (presenting VA <20/32 in the better eye) was 1.9% (95% CI, 1.0-2.9; 55 subjects). In multivariate logistic regression analysis, age (P = 0.001) was a significant predictor, and female gender (P = 0.08) and Yao ethnicity (P = 0.09) were borderline significant predictors of the presence of any visual impairment. Visual impairment is not a public health concern in this primary school-aged population; however, visually impaired children in the community were not studied. From this baseline, future surveys could determine the effect of increasing urbanization on myopia prevalence in this population. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D
2014-01-01
The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.
Discoveries and Breakthroughs Inside Science:Informal Education for STEM and AGU Related Sciences
NASA Astrophysics Data System (ADS)
Lorditch, E.
2007-12-01
As a primary source of news, more people rely on local TV news than any other medium for their news and information. As a result, The American Geophysical Union has partnered with the American Institute of Physics in their production of Discoveries and Breakthroughs Inside Science (DBIS). DBIS is syndicated science news service that distributes 12, 90-second science news segments to over 90 local TV stations throughout the USA each month. While the segments cover a wide range of STEM (science, technology, engineering, and mathematics)topics, approximately 4 of these segments each month focus on research topics of interest to AGU members. Meet DBIS's senior science editor and learn about DBIS. Find out how you can participate in a DBIS segment, help with DBIS production, learn how DBIS segment topics are chosen, and hear why the AGU got involved with DBIS and how they work with the program.
Xiao, Ou; Morgan, Ian G; Ellwein, Leon B; He, Mingguang
2015-09-01
To estimate the age-, gender-, and ethnicity-specific prevalence of amblyopia in children aged 5 to 15 years using data from the multi-country Refractive Error Study in Children (RESC). Population-based, cross-sectional study. Among 46 260 children aged 5 to 15 years who were enumerated from 8 sites in the RESC study, 39 551 had a detailed ocular examination and a reliable visual acuity (VA) measurement in 1 or both eyes. Information on ethnicity was available for 39 321 of these participants. This study focused on findings from the 39 321 children. The examination included VA measurements, evaluation of ocular alignment and refractive error under cycloplegia, and examination of the external eye, anterior segment, media, and fundus. The proportion of children aged 5 to 15 years with amblyopia in different ethnic cohorts. Amblyopia was defined as best-corrected visual acuity (BCVA) of ≤20/40 in either eye, with tropia, anisometropia (≥2 spherical equivalent diopters [D]), or hyperopia (≥+6 spherical equivalent D), after excluding children with fundus or anterior segment abnormalities. The overall prevalence of amblyopia was 0.74% (95% confidence interval, 0.64-0.83) with significant (P < 0.001) variation across ethnic groups: 1.43% in Hispanic, 0.93% in Chinese, 0.62% in Indian, 0.52% in Malay, 0.35% in Nepali, and 0.28% in African children. Amblyopia was not associated with age or gender. The most common cause of amblyopia was anisometropia. In this study, the prevalence of amblyopia varied with ethnicity and was highest in Hispanic children and lowest in African children. Most cases were unilateral and developed before the age of 5 years. The impact of changes of definitions on prevalence estimates is discussed. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Neotectonic Deformation in Central Eurasia: A Geodynamic Model Approach
NASA Astrophysics Data System (ADS)
Tunini, Lavinia; Jiménez-Munt, Ivone; Fernandez, Manel; Vergés, Jaume; Bird, Peter
2017-11-01
Central Eurasia hosts wide orogenic belts of collision between India and Arabia with Eurasia, with diffuse or localized deformation occurring up to hundreds of kilometers from the primary plate boundaries. Although numerous studies have investigated the neotectonic deformation in central Eurasia, most of them have focused on limited segments of the orogenic systems. Here we explore the neotectonic deformation of all of central Eurasia, including both collision zones and the links between them. We use a thin-spherical sheet approach in which lithosphere strength is calculated from lithosphere structure and its thermal regime. We investigate the contributions of variations in lithospheric structure, rheology, boundary conditions, and fault friction coefficients on the predicted velocity and stress fields. Results (deformation pattern, surface velocities, tectonic stresses, and slip rates on faults) are constrained by independent observations of tectonic regime, GPS, and stress data. Our model predictions reproduce the counterclockwise rotation of Arabia and Iran, the westward escape of Anatolia, and the eastward extrusion of the northern Tibetan Plateau. To simulate the observed extensional faults in the Tibetan Plateau, a weaker lithosphere is required, provided by a change in the rheological parameters. The southward movement of the SE Tibetan Plateau can be explained by the combined effects of the Sumatra trench retreat, a thinner lithospheric mantle, and strik-slip faults in the region. This study offers a comprehensive model for regions with little or no data coverage, like the Arabia-India intercollision zone, where the surface velocity is northward showing no deflection related to Arabia and India indentations.
Luck, Jeff; Hagigi, Fred; Parker, Louise E; Yano, Elizabeth M; Rubenstein, Lisa V; Kirchner, JoAnn E
2009-09-28
Collaborative care models for depression in primary care are effective and cost-effective, but difficult to spread to new sites. Translating Initiatives for Depression into Effective Solutions (TIDES) is an initiative to promote evidence-based collaborative care in the U.S. Veterans Health Administration (VHA). Social marketing applies marketing techniques to promote positive behavior change. Described in this paper, TIDES used a social marketing approach to foster national spread of collaborative care models. The approach relied on a sequential model of behavior change and explicit attention to audience segmentation. Segments included VHA national leadership, Veterans Integrated Service Network (VISN) regional leadership, facility managers, frontline providers, and veterans. TIDES communications, materials and messages targeted each segment, guided by an overall marketing plan. Depression collaborative care based on the TIDES model was adopted by VHA as part of the new Primary Care Mental Health Initiative and associated policies. It is currently in use in more than 50 primary care practices across the United States, and continues to spread, suggesting success for its social marketing-based dissemination strategy. Development, execution and evaluation of the TIDES marketing effort shows that social marketing is a promising approach for promoting implementation of evidence-based interventions in integrated healthcare systems.
Grzelakowski, Krzysztof P
2013-07-01
An instrumental realization of the idea for the electron emission spectromicroscope based on the newly developed imaging energy filter called α-SDA (Spherical Deflector Analyzer) is reported. Its compact design enables the realization of the flange-on spectromicroscope concept. It is equipped with two independent energy selective imaging channels: one for real and another for reciprocal space visualization. These images can be acquired quasi-simultaneousely by means of the software based on the switching on and off potentials of the energy filter. An electron gun located inside the immersion objective lens allows a new kind of sample illumination by high energy primary electrons and thus, opens a new application field for electron spectromicroscopy under laboratory conditions. Copyright © 2013 Elsevier B.V. All rights reserved.
Giant and thrombosed left ventricular aneurysm
de Agustin, Jose Alberto; de Diego, Jose Juan Gomez; Marcos-Alberca, Pedro; Rodrigo, Jose Luis; Almeria, Carlos; Mahia, Patricia; Luaces, Maria; Garcia-Fernandez, Miguel Angel; Macaya, Carlos; de Isla, Leopoldo Perez
2015-01-01
Left ventricular aneurysms are a frequent complication of acute extensive myocardial infarction and are most commonly located at the ventricular apex. A timely diagnosis is vital due to the serious complications that can occur, including heart failure, thromboembolism, or tachyarrhythmias. We report the case of a 78-year-old male with history of previous anterior myocardial infarction and currently under evaluation by chronic heart failure. Transthoracic echocardiogram revealed a huge thrombosed and calcified anteroapical left ventricular aneurysm. Coronary angiography demonstrated that the left anterior descending artery was chronically occluded, and revealed a big and spherical mass with calcified borders in the left hemithorax. Left ventriculogram confirmed that this spherical mass was a giant calcified left ventricular aneurysm, causing very severe left ventricular systolic dysfunction. The patient underwent cardioverter-defibrillator implantation for primary prevention. PMID:26225205
Size- and shape-dependent clinical and mycological efficacy of silver nanoparticles on dandruff.
Anwar, Mohammad F; Yadav, Deepak; Jain, Swati; Kapoor, Sumeet; Rastogi, Shweta; Arora, Indu; Samim, Mohammed
2016-01-01
Dandruff is a prominent scalp problem caused by the growth of fungus Malassezia furfur, potentially cascading into dermal inflammation, itching, and tissue damage. The present work outlines a detailed analysis of the treatment of scalp infection using silver nanomaterials (Ag NMs), and focuses on biocidal activity owing to manipulation of size, shape, and structure. Monodisperse silver spherical nanoparticles (NPs) and nanorods (NRs) were synthesized by chemical routes that were characterized using analytical and spectroscopic techniques. Ag NMs demonstrated enhanced biocidal tendencies compared to market available drugs, itracanozole and ketoconazole, showing greater zones of inhibition. The obtained 20 nm and 50 nm spherical-shaped NPs and 50 nm NRs showed concentration-, size-, and shape-dependent antifungal activity, with 20 nm spherical-shaped NPs exhibiting excellent potency. Minimum inhibitory concentration for 20 nm was lowest at 0.2 mg/mL in comparison to 0.3 mg/mL for NRs. Primary irritation index was 0.33 and 0.16 for 20 nm and 50 nm spherical-shaped NPs, respectively, while 50 nm rod-shaped NMs exhibited negligible redness. An in vivo model for M. furfur infection was generated by passing fungi subcutaneously in rats' skin. Again, 20 nm particles showed best normalization of skin after 10 days on regular dosing, in comparison with bigger and rod-shaped particles. The statistical clinical score was highest for Ag nanorods, followed by 50 nm Ag NPs-treated animals. It was observed that 20 nm spherical particles exhibited the lowest score (0) compared with others as well as with antifungal drugs. Biochemical analysis performed by checking antioxidant enzymatic activities indicated tissue repair and normalization of enzymes and protein concentration by Ag NPs.
Size- and shape-dependent clinical and mycological efficacy of silver nanoparticles on dandruff
Anwar, Mohammad F; Yadav, Deepak; Jain, Swati; Kapoor, Sumeet; Rastogi, Shweta; Arora, Indu; Samim, Mohammed
2016-01-01
Dandruff is a prominent scalp problem caused by the growth of fungus Malassezia furfur, potentially cascading into dermal inflammation, itching, and tissue damage. The present work outlines a detailed analysis of the treatment of scalp infection using silver nanomaterials (Ag NMs), and focuses on biocidal activity owing to manipulation of size, shape, and structure. Monodisperse silver spherical nanoparticles (NPs) and nanorods (NRs) were synthesized by chemical routes that were characterized using analytical and spectroscopic techniques. Ag NMs demonstrated enhanced biocidal tendencies compared to market available drugs, itracanozole and ketoconazole, showing greater zones of inhibition. The obtained 20 nm and 50 nm spherical-shaped NPs and 50 nm NRs showed concentration-, size-, and shape-dependent antifungal activity, with 20 nm spherical-shaped NPs exhibiting excellent potency. Minimum inhibitory concentration for 20 nm was lowest at 0.2 mg/mL in comparison to 0.3 mg/mL for NRs. Primary irritation index was 0.33 and 0.16 for 20 nm and 50 nm spherical-shaped NPs, respectively, while 50 nm rod-shaped NMs exhibited negligible redness. An in vivo model for M. furfur infection was generated by passing fungi subcutaneously in rats’ skin. Again, 20 nm particles showed best normalization of skin after 10 days on regular dosing, in comparison with bigger and rod-shaped particles. The statistical clinical score was highest for Ag nanorods, followed by 50 nm Ag NPs-treated animals. It was observed that 20 nm spherical particles exhibited the lowest score (0) compared with others as well as with antifungal drugs. Biochemical analysis performed by checking antioxidant enzymatic activities indicated tissue repair and normalization of enzymes and protein concentration by Ag NPs. PMID:26792991
Rotationally invariant clustering of diffusion MRI data using spherical harmonics
NASA Astrophysics Data System (ADS)
Liptrot, Matthew; Lauze, François
2016-03-01
We present a simple approach to the voxelwise classification of brain tissue acquired with diffusion weighted MRI (DWI). The approach leverages the power of spherical harmonics to summarise the diffusion information, sampled at many points over a sphere, using only a handful of coefficients. We use simple features that are invariant to the rotation of the highly orientational diffusion data. This provides a way to directly classify voxels whose diffusion characteristics are similar yet whose primary diffusion orientations differ. Subsequent application of machine-learning to the spherical harmonic coefficients therefore may permit classification of DWI voxels according to their inferred underlying fibre properties, whilst ignoring the specifics of orientation. After smoothing apparent diffusion coefficients volumes, we apply a spherical harmonic transform, which models the multi-directional diffusion data as a collection of spherical basis functions. We use the derived coefficients as voxelwise feature vectors for classification. Using a simple Gaussian mixture model, we examined the classification performance for a range of sub-classes (3-20). The results were compared against existing alternatives for tissue classification e.g. fractional anisotropy (FA) or the standard model used by Camino.1 The approach was implemented on both two publicly-available datasets: an ex-vivo pig brain and in-vivo human brain from the Human Connectome Project (HCP). We have demonstrated how a robust classification of DWI data can be performed without the need for a model reconstruction step. This avoids the potential confounds and uncertainty that such models may impose, and has the benefit of being computable directly from the DWI volumes. As such, the method could prove useful in subsequent pre-processing stages, such as model fitting, where it could inform about individual voxel complexities and improve model parameter choice.
LDR segmented mirror technology assessment study
NASA Technical Reports Server (NTRS)
Krim, M.; Russo, J.
1983-01-01
In the mid-1990s, NASA plans to orbit a giant telescope, whose aperture may be as great as 30 meters, for infrared and sub-millimeter astronomy. Its primary mirror will be deployed or assembled in orbit from a mosaic of possibly hundreds of mirror segments. Each segment must be shaped to precise curvature tolerances so that diffraction-limited performance will be achieved at 30 micron (nominal operating wavelength). All panels must lie within 1 micron on a theoretical surface described by the optical precipitation of the telescope's primary mirror. To attain diffraction-limited performance, the issues of alignment and/or position sensing, position control of micron tolerances, and structural, thermal, and mechanical considerations for stowing, deploying, and erecting the reflector must be resolved. Radius of curvature precision influences panel size, shape, material, and type of construction. Two superior material choices emerged: fused quartz (sufficiently homogeneous with respect to thermal expansivity to permit a thin shell substrate to be drape molded between graphite dies to a precise enough off-axis asphere for optical finishing on the as-received a segment) and a Pyrex or Duran (less expensive than quartz and formable at lower temperatures). The optimal reflector panel size is between 1-1/2 and 2 meters. Making one, two-meter mirror every two weeks requires new approaches to manufacturing off-axis parabolic or aspheric segments (drape molding on precision dies and subsequent finishing on a nonrotationally symmetric dependent machine). Proof-of-concept developmental programs were identified to prove the feasibility of the materials and manufacturing ideas.
Effect and Safety of Morphine Use in Acute Anterior ST-Segment Elevation Myocardial Infarction.
Bonin, Mickael; Mewton, Nathan; Roubille, Francois; Morel, Olivier; Cayla, Guillaume; Angoulvant, Denis; Elbaz, Meyer; Claeys, Marc J; Garcia-Dorado, David; Giraud, Céline; Rioufol, Gilles; Jossan, Claire; Ovize, Michel; Guerin, Patrice
2018-02-10
Morphine is commonly used to treat chest pain during myocardial infarction, but its effect on cardiovascular outcome has never been directly evaluated. The aim of this study was to examine the effect and safety of morphine in patients with acute anterior ST-segment elevation myocardial infarction followed up for 1 year. We used the database of the CIRCUS (Does Cyclosporine Improve Outcome in ST Elevation Myocardial Infarction Patients) trial, which included 969 patients with anterior ST-segment elevation myocardial infarction, admitted for primary percutaneous coronary intervention. Two groups were defined according to use of morphine preceding coronary angiography. The composite primary outcome was the combined incidence of major adverse cardiovascular events, including cardiovascular death, heart failure, cardiogenic shock, myocardial infarction, unstable angina, and stroke during 1 year. A total of 554 (57.1%) patients received morphine at first medical contact. Both groups, with and without morphine treatment, were comparable with respect to demographic and periprocedural characteristics. There was no significant difference in major adverse cardiovascular events between patients who received morphine compared with those who did not (26.2% versus 22.0%, respectively; P =0.15). The all-cause mortality was 5.3% in the morphine group versus 5.8% in the no-morphine group ( P =0.89). There was no difference between groups in infarct size as assessed by the creatine kinase peak after primary percutaneous coronary intervention (4023±118 versus 3903±149 IU/L; P =0.52). In anterior ST-segment elevation myocardial infarction patients treated by primary percutaneous coronary intervention, morphine was used in half of patients during initial management and was not associated with a significant increase in major adverse cardiovascular events at 1 year. © 2018 The Authors and Hospices Civils de Lyon. Published on behalf of the American Heart Association, Inc., by Wiley.
Jang, Woo Jin; Yang, Jeong Hoon; Song, Young Bin; Chun, Woo Jung; Oh, Ju Hyeon; Park, Yong Hwan; Lee, Mi Rae; Hwang, Jin Kyung; Hwang, Ji-Won; Hahn, Joo-Yong; Choi, Seung-Hyuk; Lee, Sang-Chol; Choe, Yeon Hyeon; Gwon, Hyeon-Cheol
2017-04-24
Little is known about causality and pathological mechanism underlying association of postinfarct fever with myocardial injury in patients with ST-segment elevation myocardial infarction. In 276 patients undergoing primary percutaneous coronary intervention for ST-segment elevation myocardial infarction, cardiac magnetic resonance imaging was performed a median of 3.4 days after the index procedure. Forty-five patients had postinfarct fever (peak body temperature within 4 days after primary percutaneous coronary intervention ≥37.7°C; Fever group) whereas 231 did not (no-Fever group). Primary outcome was myocardial infarct size as assessed by cardiac magnetic resonance imaging. Secondary outcomes were extent of area at risk, myocardial salvage index, and microvascular obstruction area. In cardiac magnetic resonance imaging analysis, myocardial infarct size (25.6% [19.7-32.4] in the Fever group versus 17.2% [11.8-25.4] in the no-Fever group; P <0.01), extent of area at risk (43.7% [31.9-54.9] versus 35.3% [24.0-43.7]; P <0.01), and microvascular obstruction area (4.4% [0.0-13.2] versus 1.2% [0.0-5.1]; P =0.02) were greater in the Fever group than in the no-Fever group. Myocardial salvage index tended to be lower in the Fever group compared to the no-Fever group (37.7 [28.5-56.1] versus 47.0 [34.1-56.8]; P =0.13). In multivariate analysis, postinfarct fever was associated with larger myocardial infarct (odds ratio, 3.48; 95% CI, 1.71-7.07; P <0.01) and lower MSI (odds ratio, 2.10; 95% CI, 1.01-4.08; P =0.03). Postinfarct fever could predict advanced myocardial injury and less salvaged myocardium in ST-segment elevation myocardial infarction patients undergoing primary percutaneous coronary intervention. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Garrett, Kevin M; Levitt, Marc A; Peña, Alberto; Kraus, Steven J
2012-09-01
The radiologic evaluation of Hirschsprung disease is well described in the literature. However, there is a paucity of literature describing the appearance of the neo-rectum and colon after repair, specifically describing findings in patients with poor functional outcome, which would suggest the need for reoperation. We describe findings on contrast enema and correlate them with surgical findings at reoperation in children with poor functional outcome after primary repair for Hirschsprung disease who suffer from bowel dysfunction that can manifest with either soiling or obstructive symptoms such as enterocolitis. Children were identified from our colorectal surgery database. At the time of abstract submission, 35 children had contrast enemas prior to reoperation. Additional children continue to present for evaluation. The majority of children included in the study had their primary repair performed elsewhere. The initial procedures included: Duhamel (n = 11), Soave (n = 20) or Swenson (n = 3). One child had undergone a primary Soave repair and subsequently had a Swenson-type reoperation but continued to have a poor outcome. One child's initial surgical repair could not be determined. Images were reviewed by a staff pediatric radiologist and a pediatric radiology fellow. Findings encountered on contrast enema in these children include a distal narrowed segment due to stricture or aganglionic/transitional zone segment (8), dilated/hypomotile distal segment (7), thickened presacral space due to compressing Soave cuff (11), dilated Duhamel pouch (8), active enterocolitis (3) and partially obstructing twist of the pull-through segment (1). Multiple anatomical and pathological complications exist that can lead to bowel dysfunction in children after repair of Hirschsprung disease. Little recent literature exists regarding the radiographic findings in children. We had the opportunity to review a substantial series of these children, describe the contrast enema findings in these difficult cases and correlate them with operative findings. Radiologic evaluation is key to assessing such patients; it defines the potential anatomical problem with the pull-through and facilitates surgical planning.
Wavefront Analysis of Adaptive Telescope
NASA Technical Reports Server (NTRS)
Hadaway, James B.; Hillman, Lloyd
1997-01-01
The motivation for this work came from a NASA Headquarters interest in investigating design concepts for a large space telescope employing active optics technology. Current and foreseeable launch vehicles will be limited to carrying around 4-5 meter diameter objects. Thus, if a large, filled-aperture telescope (6-20 meters in diameter) is to be placed in space, it will be required to have a deployable primary mirror. Such a mirror may be an inflatable membrane or a segmented mirror consisting of many smaller pieces. In any case, it is expected that the deployed primary will not be of sufficient quality to achieve diffraction-limited performance for its aperture size. Thus, an active optics system will be needed to correct for initial as well as environmentally-produced primary figure errors. Marshall Space Flight Center has developed considerable expertise in the area of active optics with the PAMELA test-bed. The combination of this experience along with the Marshall optical shop's work in mirror fabrication made MSFC the logical choice to lead NASA's effort to develop active optics technology for large, space-based, astronomical telescopes. Furthermore, UAH's support of MSFC in the areas of optical design, fabrication, and testing of space-based optical systems placed us in a key position to play a major role in the development of this future-generation telescope. A careful study of the active optics components had to be carried out in order to determine control segment size, segment quality, and segment controllability required to achieve diffraction-limited resolution with a given primary mirror. With this in mind, UAH undertook the following effort to provide NASA/MSFC with optical design and analysis support for the large telescope study. All of the work performed under this contract has already been reported, as a team member with MSFC, to NASA Headquarters in a series of presentations given between May and December of 1995. As specified on the delivery order, this report simply summarizes the material with the various UAH-written presentation packages attached as appendices.
Measurements of water uptake of maize roots: the key function of lateral roots
NASA Astrophysics Data System (ADS)
Ahmed, M. A.; Zarebanadkouki, M.; Kroener, E.; Kaestner, A.; Carminati, A.
2014-12-01
Maize (Zea mays L.) is one of the most important crop worldwide. Despite its importance, there is limited information on the function of different root segments and root types of maize in extracting water from soils. Therefore, the aim of this study was to investigate locations of root water uptake in maize. We used neutron radiography to: 1) image the spatial distribution of maize roots in soil and 2) trace the transport of injected deuterated water (D2O) in soil and roots. Maizes were grown in aluminum containers (40×38×1 cm) filled with a sandy soil. When the plants were 16 days old, we injected D2O into selected soil regions containing primary, seminal and lateral roots. The experiments were performed during the day (transpiring plants) and night (not transpiring plants). The transport of D2O into roots was simulated using a new convection-diffusion numerical model of D2O transport into roots. By fitting the observed D2O transport we quantified the diffusional permeability and the water uptake of the different root segments. The maize root architecture consisted of a primary root, 4-5 seminal roots and many lateral roots connected to the primary and seminal roots. Laterals emerged from the proximal 15 cm of the primary and seminal roots. Water uptake occurred primarily in lateral roots. Lateral roots had the highest diffusional permeability (9.4×10-7), which was around six times higher that the diffusional permeability of the old seminal segments (1.4×10-7), and two times higher than the diffusional permeability of the young seminal segments (4.7×10-7). The radial flow of D2O into the lateral (6.7×10-5 ) was much higher than in the young seminal roots (1.1×10-12). The radial flow of D2O into the old seminal was negligible. We concluded that the function of the primary and seminal roots was to collect water from the lateral roots and transport it to the shoot. A maize root system with lateral roots branching from deep primary and seminal roots would be efficient in extracting water from the subsoil and better tolerate periods of water shortage. However, in this case the xylem axial resistance could be the limiting factor for the uptake of water.
Aerothermodynamic optimization of Earth entry blunt body heat shields for Lunar and Mars return
NASA Astrophysics Data System (ADS)
Johnson, Joshua E.
A differential evolutionary algorithm has been executed to optimize the hypersonic aerodynamic and stagnation-point heat transfer performance of Earth entry heat shields for Lunar and Mars return manned missions with entry velocities of 11 and 12.5 km/s respectively. The aerothermodynamic performance of heat shield geometries with lift-to-drag ratios up to 1.0 is studied. Each considered heat shield geometry is composed of an axial profile tailored to fit a base cross section. Axial profiles consist of spherical segments, spherically blunted cones, and power laws. Heat shield cross sections include oblate and prolate ellipses, rounded-edge parallelograms, and blendings of the two. Aerothermodynamic models are based on modified Newtonian impact theory with semi-empirical correlations for convection and radiation. Multi-objective function optimization is performed to determine optimal trade-offs between performance parameters. Objective functions consist of minimizing heat load and heat flux and maximizing down range and cross range. Results indicate that skipping trajectories allow for vehicles with L/D = 0.3, 0.5, and 1.0 at lunar return flight conditions to produce maximum cross ranges of 950, 1500, and 3000 km respectively before Qs,tot increases dramatically. Maximum cross range increases by ˜20% with an increase in entry velocity from 11 to 12.5 km/s. Optimal configurations for all three lift-to-drag ratios produce down ranges up to approximately 26,000 km for both lunar and Mars return. Assuming a 10,000 kg mass and L/D = 0.27, the current Orion configuration is projected to experience a heat load of approximately 68 kJ/cm2 for Mars return flight conditions. For both L/D = 0.3 and 0.5, a 30% increase in entry vehicle mass from 10,000 kg produces a 20-30% increase in Qs,tot. For a given L/D, highly-eccentric heat shields do not produce greater cross range or down range. With a 5 g deceleration limit and L/D = 0.3, a highly oblate cross section with an eccentricity of 0.968 produces a 35% reduction in heat load over designs with zero eccentricity due to the eccentric heat shield's greater drag area that allows the vehicle to decelerate higher in the atmosphere. In this case, the heat shield's drag area is traded off with volumetric efficiency while fulfilling the given set of mission requirements. Additionally, the high radius-of-curvature of the spherical segment axial profile provides the best combination of heat transfer and aerodynamic performance for both entry velocities and a 5 g deceleration limit.
Browning, D J
2000-11-01
To determine the relative frequencies of signs in posterior segment ocular syphilis, the response to a neurosyphilis regimen of penicillin, and differences in findings between human immunodeficiency virus (HIV)-coinfected and -noncoinfected patients in a community setting. Retrospective, noncomparative, consecutive case series. Fourteen consecutive patients with posterior segment ocular syphilis over a 14-year period within or during the acquired immune deficiency syndrome era. Neurosyphilis intravenous penicillin regimen. Initial and final visual acuity; treponemal and nontreponemal serologic analyses; cerebrospinal fluid cell count, protein, and Venereal Disease Research Laboratory analyses; posterior segment signs; and relapses and recurrences. Blacks and males were predominantly affected. Five (36%) of patients were HIV coinfected, and ocular syphilis led to the HIV infection diagnosis in three. Four (29%) patients had received previous antibiotic therapy for primary or secondary syphilis, raising the suspicion of relapse. Two patients had negative nontreponemal serologic results. All patients responded rapidly to neurosyphilis therapy. One patient subsequently relapsed after neurosyphilis therapy, and a second was reinfected with recurrence of ocular involvement. One previously undescribed retinal manifestation was discovered: a sectorial retinochoroiditis with delayed retinal circulation in the involved area. Ocular syphilis is a form of neurosyphilis and requires neurosyphilis therapy regardless of when it develops after primary infection. Conventional syphilis staging is of little use in understanding ocular syphilis. A high suspicion for this diagnosis is appropriate, especially in poorer black males with posterior segment inflammatory disease. Human immunodeficiency virus coinfection with ocular syphilis is common, but does not affect response to a neurosyphilis regimen of penicillin in the short term. Awareness of the multiple presentations of posterior segment ocular syphilis will aid ophthalmologists in averting misdiagnosis or delayed diagnosis.
Pu, Jun; Ding, Song; Ge, Heng; Han, Yaling; Guo, Jinchen; Lin, Rong; Su, Xi; Zhang, Heng; Chen, Lianglong; He, Ben
2017-10-17
Timely primary percutaneous coronary intervention (PPCI) cannot be offered to all patients with ST-segment-elevation myocardial infarction (STEMI). Pharmaco-invasive (PhI) strategy has been proposed as a valuable alternative for eligible patients with STEMI. We conducted a randomized study to compare the efficacy and safety of a PhI strategy with half-dose fibrinolytic regimen versus PPCI in patients with STEMI. The EARLY-MYO trial (Early Routine Catheterization After Alteplase Fibrinolysis Versus Primary PCI in Acute ST-Segment-Elevation Myocardial Infarction) was an investigator-initiated, prospective, multicenter, randomized, noninferiority trial comparing a PhI strategy with half-dose alteplase versus PPCI in patients with STEMI 18 to 75 years of age presenting ≤6 hours after symptom onset but with an expected PCI-related delay. The primary end point of the study was complete epicardial and myocardial reperfusion after PCI, defined as thrombolysis in myocardial infarction flow grade 3, thrombolysis in myocardial infarction myocardial perfusion grade 3, and ST-segment resolution ≥70%. We also measured infarct size and left ventricular ejection fraction with cardiac magnetic resonance and recorded 30-day clinical and safety outcomes. A total of 344 patients from 7 centers were randomized to PhI (n=171) or PPCI (n=173). PhI was noninferior (and even superior) to PPCI for the primary end point (34.2% versus 22.8%, P noninferiority <0.05, P superiority =0.022), with no significant differences in the frequency of the individual components of the combined end point: thrombolysis in myocardial infarction flow 3 (91.3% versus 89.2%, P =0.580), thrombolysis in myocardial infarction myocardial perfusion grade 3 (65.8% versus 62.9%, P =0.730), and ST-segment resolution ≥70% (50.9% versus 45.5%, P =0.377). Infarct size (23.3%±11.3% versus 25.8%±13.7%, P =0.101) and left ventricular ejection fraction (52.2%±11.0% versus 51.4%±12.0%, P =0.562) were similar in both groups. No significant differences occurred in 30-day rates of total death (0.6% versus 1.2%, P =1.0), reinfarction (0.6% versus 0.6%, P =1.0), heart failure (13.5% versus 16.2%, P =0.545), major bleeding events (0.6% versus 0%, P =0.497), or intracranial hemorrhage (0% versus 0%), but minor bleeding (26.9% versus 11.0%, P <0.001) was observed more often in the PhI group. For patients with STEMI presenting ≤6 hours after symptom onset and with an expected PCI-related delay, a PhI strategy with half-dose alteplase and timely PCI offers more complete epicardial and myocardial reperfusion when compared with PPCI. Adequately powered trials with this reperfusion strategy to assess clinical and safety outcomes are warranted. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01930682. © 2017 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Ahmed, Mutez A.; Zarebanadkouki, Mohsen; Kroener, Eva; Carminati, Andrea
2015-04-01
Water availability is a primary constraint to the global crop production. Although maize (Zea mays L.) is one of the most important crops worldwide, there is limited information on the function of different root segments and types in extracting water from soils. Aim of this study was to investigate the location of water uptake in maize roots. We used neutron radiography to: 1) image the spatial distribution of maize roots in soil and 2) trace the transport of injected deuterated water (D2O) in soil and roots. Maize plants were grown in aluminum containers (40×38×1 cm) filled with sandy soil. The soil was partitioned into different compartments using 1-cm-thick layers of coarse sand. When the plants were two weeks-old we injected D2O into selected soil compartments. The experiments were performed during the day (transpiring plants) and night (non transpiring plants). The transport of D2O into roots was simulated using a convection-diffusion numerical model of D2O transport into roots. By fitting the observed D2O transport we quantified the diffusion coefficient and the water uptake of the different root segments. The maize root architecture consisted of a primary root, 4-5 seminal roots and many lateral roots connected to the primary and seminal roots. Laterals emerged from the proximal 15 cm of the primary and seminal roots. Both during day and night measurements, D2O entered more quickly into lateral roots than into primary and seminal roots. The quick transport of D2O into laterals was caused by the small radius of lateral roots. The diffusion coefficient of lateral roots (4.68×10-7cm2s-1)was similar to that of the distal segments of seminal roots (4.72×10-7cm2s-1) and higher than of the proximal segments (1.42×10-7cm2s-1). Water uptake of lateral roots (1.64×10-5cms-1)was much higher than that of the distal segments of seminal roots (1.18×10-12cms-1). Water uptake of the proximal seminal segments was negligible. We conclude that the function of lateral roots is to absorb water from the soil, while the function of the primary and seminal roots is to axially transport water to the shoot. Breeding for lateral roots with high radial conductivity and seminal roots with large xylem vessels diameter would be beneficial in agroecosystems where water is available. In contrast, in arid and semi-arid areas seminal roots with a smaller xylem vessel diameter combined with deep branching of laterals would reduce transpiration rate and at the same time allow the uptake of water stored in the subsoil (Richards and Passioura 1989). Reference Richards RA, Passioura JB. (1989) A breeding program to reduce the diameter of the major xylem vessel in the seminal roots of wheat and its effect on grain yield in rain-fed environments. Australian Journal of Agricultural Research 40, 943-950.
Herman, Emily K.; Greninger, Alexander L.; Visvesvara, Govinda S.; Marciano-Cabral, Francine; Dacks, Joel B.; Chiu, Charles Y.
2013-01-01
Naegleria fowleri is a unicellular eukaryote causing primary amoebic meningoencephalitis, a neuropathic disease killing 99% of those infected, usually within 7–14 days. N. fowleri is found globally in regions including the US and Australia. The genome of the related non-pathogenic species Naegleria gruberi has been sequenced, but the genetic basis for N. fowleri pathogenicity is unclear. To generate such insight, we sequenced and assembled the mitochondrial genome and a 60-kb segment of nuclear genome from N. fowleri. The mitochondrial genome is highly similar to its counterpart in N. gruberi in gene complement and organization, while distinct lack of synteny is observed for the nuclear segments. Even in this short (60-kb) segment, we identified examples of potential factors for pathogenesis, including ten novel N. fowleri-specific genes. We also identified a homologue of cathepsin B; proteases proposed to be involved in the pathogenesis of diverse eukaryotic pathogens, including N. fowleri. Finally, we demonstrate a likely case of horizontal gene transfer between N. fowleri and two unrelated amoebae, one of which causes granulomatous amoebic encephalitis. This initial look into the N. fowleri nuclear genome has revealed several examples of potential pathogenesis factors, improving our understanding of a neglected pathogen of increasing global importance. PMID:23360210
Formation of Low Symmetry Ordered Phases in Block Polymer Melts
NASA Astrophysics Data System (ADS)
Bates, Frank
Until recently the phase behavior of asymmetric AB diblock copolymers in the melt state was universally accepted as a solved problem: spherical domains packed on a body centered cubic (BCC) lattice. Recent experiments with low molecular weight diblocks have upended this picture, beginning with the discovery of the Frank-Kasper sigma phase in poly(isoprene)- b-poly(lactide) (PI-PLA) followed recently by the identification of a dodecagonal quasicrystal phase (DDQC) as a metastable state that evolves from the supercooled disordered liquid. Self-consistent mean-field theory shows that introducing conformational asymmetry (bA >bB where b is the statistical segment length) opens a window in the phase portrait at fA <<1/2 that supports the formation of various low symmetry ordered phases. However, contrary to the widely accepted mean-field picture, the disordered state near the order-disorder transition (ODT) is highly structured and rapid cooling of this micellar fluid several tens of degrees below the ODT temperature arrests macromolecular chain exchange transitioning the material from an ergodic to non-ergodic state. We have explored the evolution of order following such temperature quenches and during subsequent reheating using synchrotron small-angle X-ray scattering (SAXS) revealing surprising analogies with the behavior of metal alloys. This presentation will associate the formation of ordered low symmetry phases with the concept of sphericity, the tendency for the self-assembled nanoparticles to be spherical in competition with the constraints imposed by periodic and aperiodic packing without voids and subject to the condition of incompressibility. Supported by NSF-DMR-1104368. This work was conducted in collaboration with Kyungtae Kim, Morgan Schulze, Akash Arora, Ronald Lewis, Timothy Gillard, Sangwoo Lee, Kevin Dorfman and Marc Hillmyer.
Pulmonary tumor measurements from x-ray computed tomography in one, two, and three dimensions.
Villemaire, Lauren; Owrangi, Amir M; Etemad-Rezai, Roya; Wilson, Laura; O'Riordan, Elaine; Keller, Harry; Driscoll, Brandon; Bauman, Glenn; Fenster, Aaron; Parraga, Grace
2011-11-01
We evaluated the accuracy and reproducibility of three-dimensional (3D) measurements of lung phantoms and patient tumors from x-ray computed tomography (CT) and compared these to one-dimensional (1D) and two-dimensional (2D) measurements. CT images of three spherical and three irregularly shaped tumor phantoms were evaluated by three observers who performed five repeated measurements. Additionally, three observers manually segmented 29 patient lung tumors five times each. Follow-up imaging was performed for 23 tumors and response criteria were compared. For a single subject, imaging was performed on nine occasions over 2 years to evaluate multidimensional tumor response. To evaluate measurement accuracy, we compared imaging measurements to ground truth using analysis of variance. For estimates of precision, intraobserver and interobserver coefficients of variation and intraclass correlations (ICC) were used. Linear regression and Pearson correlations were used to evaluate agreement and tumor response was descriptively compared. For spherical shaped phantoms, all measurements were highly accurate, but for irregularly shaped phantoms, only 3D measurements were in high agreement with ground truth measurements. All phantom and patient measurements showed high intra- and interobserver reproducibility (ICC >0.900). Over a 2-year period for a single patient, there was disagreement between tumor response classifications based on 3D measurements and those generated using 1D and 2D measurements. Tumor volume measurements were highly reproducible and accurate for irregular, spherical phantoms and patient tumors with nonuniform dimensions. Response classifications obtained from multidimensional measurements suggest that 3D measurements provide higher sensitivity to tumor response. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Meng, Lixin; Meng, Lingchen; Zhang, Yiqun; Zhang, Lizhong; Liu, Ming; Li, Xiaoming
2018-01-01
In the satellite to earth laser communication link, large-aperture ground laser communication terminals usually are used in order to realize the requirement of high rate and long distance communication and restrain the power fluctuation by atmospheric scintillation. With the increasing of the laser communication terminal caliber, the primary mirror weight should also be increased, and selfweight, thermal deformation and environment will affect the surface accuracy of the primary mirror surface. A high precision vehicular laser communication telescope unit with an effective aperture of 600mm was considered in this paper. The primary mirror is positioned with center hole, which back is supported by 9 floats and the side is supported by a mercury band. The secondary mirror adopts a spherical adjusting mechanism. Through simulation analysis, the system wave difference is better than λ/20 when the primary mirror is in different dip angle, which meets the requirements of laser communication.
ERIC Educational Resources Information Center
Vazquez Aranda, Armando I.; Henquin, Eduardo R.; Torres, Israel Rodriguez; Bisang, Jose M.
2012-01-01
A laboratory experiment is described to determine the primary current distribution in parallel-plate electrochemical reactors. The electrolyte is simulated by conductive paper and the electrodes are segmented to measure the current distribution. Experiments are reported with the electrolyte confined to the interelectrode gap, where the current…
A newly designed big cup nitinol stent for gastric outlet obstruction
Shi, Ding; Liao, Sheng-Hui; Geng, Jian-Ping
2010-01-01
AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer. METHODS: The new stent is composed of a proximal big cup segment (20 mm in length and 48-55 mm in diameter), a middle part (60 mm in length and 20 mm in diameter) covered by a polyethylene membrane and a distal sphericity (20 mm in length and 28 mm in diameter). Half of the proximal big cup segment is also covered by a polyethlene membrane, which is adjacent to the middle part of the stent. The stent is preloaded in a 6.0-mm-diameter introducer system. Thirteen patients with gastric outlet obstruction resulting from gastric cancer received the new stents under endoscopic and fluoroscopic guidance. RESULTS: Technical success was achieved in 12 of 13 (92.3%) patients. Among the 12 patients in whom endoscopic stent was placed successfully, the clinical success rate was 91.7% during a follow-up of average 6.5 mo. During the first month follow-up, the migration rate was 0%, recurrent obstruction 0% and gastric bleeding 8.3%. During the follow-up between 2-12 mo, no migration, recurrent obstruction and gastric bleeding occurred. CONCLUSION: The proximal big cup segment seems to be effective and promising for technical efficacy, clinical outcome, and preventing migration and tumor ingrowth and increasing the emptying rate of sinus ventriculi. PMID:20806440
Early Focal Segmental Glomerulosclerosis as a Cause of Renal Allograft Primary Nonfunction
Griffin, Emma J.; Thomson, Peter C.; Kipgen, David; Clancy, Marc; Daly, Conal
2013-01-01
Background. Primary focal segmental glomerulosclerosis (FSGS) is one of the commonest causes of glomerular disease and if left untreated will often progress to established renal failure. In many cases the best treatment option is renal transplantation; however primary FSGS may rapidly recur in renal allografts and may contribute to delayed graft function. We present a case of primary nonfunction in a renal allograft due to biopsy-proven FSGS. Case Report. A 32-year-old man presented with serum albumin of 22 g/L, proteinuria quantified at 12 g/L, and marked peripheral oedema. Renal biopsy demonstrated tip-variant FSGS. Despite treatment, the patient developed progressive renal dysfunction and was commenced on haemodialysis. Cadaveric renal transplantation was undertaken; however this was complicated by primary nonfunction. Renal biopsies failed to demonstrate evidence of acute rejection but did demonstrate clear evidence of FSGS. The patient was treated to no avail. Discussion. Primary renal allograft nonfunction following transplantation is often due to acute kidney injury or acute rejection. Recurrent FSGS is recognised as a phenomenon that drives allograft dysfunction but is not traditionally associated with primary nonfunction. This case highlights FSGS as a potentially aggressive process that, once active in the allograft, may prove refractory to targeted treatment. Preemptive therapies in patients deemed to be at high risk of recurrent disease may be appropriate and should be considered. PMID:23781382
NASA Astrophysics Data System (ADS)
Rachakonda, Prem; Muralikrishnan, Bala; Cournoyer, Luc; Cheok, Geraldine; Lee, Vincent; Shilling, Meghan; Sawyer, Daniel
2017-10-01
The Dimensional Metrology Group at the National Institute of Standards and Technology is performing research to support the development of documentary standards within the ASTM E57 committee. This committee is addressing the point-to-point performance evaluation of a subclass of 3D imaging systems called terrestrial laser scanners (TLSs), which are laser-based and use a spherical coordinate system. This paper discusses the usage of sphere targets for this effort, and methods to minimize the errors due to the determination of their centers. The key contributions of this paper include methods to segment sphere data from a TLS point cloud, and the study of some of the factors that influence the determination of sphere centers.
Cavitation pitting and erosion of aluminum 6061-T6 in mineral oil water
NASA Technical Reports Server (NTRS)
Rao, B. C. S.; Buckley, D. H.
1983-01-01
Cavitation erosion studies of aluminum 6061-T6 in mineral oil and in ordinary tap water are presented. The maximum erosion rate (MDPR, or mean depth of penetration rate) in mineral oil was about four times that in water. The MDPR in mineral oil decreased continuously with time, but the MDPR in water remained approximately constant. The cavitation pits in mineral oil were of smaller diameter and depth than the pits in water. Treating the pits as spherical segments, we computed the radius r of the sphere. The logarithm of h/a, where h is the pit depth and 2a is the top width of the pit, was linear when plotted against the logarithm of 2r/h - 1.
NASA Astrophysics Data System (ADS)
Adamczewski-Musch, J.; Akishin, P.; Becker, K.-H.; Belogurov, S.; Bendarouach, J.; Boldyreva, N.; Chernogorov, A.; Deveaux, C.; Dobyrn, V.; Dürr, M.; Eschke, J.; Förtsch, J.; Heep, J.; Höhne, C.; Kampert, K.-H.; Kochenda, L.; Kopfer, J.; Kravtsov, P.; Kres, I.; Lebedev, S.; Lebedeva, E.; Leonova, E.; Linev, S.; Mahmoud, T.; Michel, J.; Miftakhov, N.; Niebur, W.; Ovcharenko, E.; Patel, V.; Pauly, C.; Pfeifer, D.; Querchfeld, S.; Rautenberg, J.; Reinecke, S.; Riabov, Y.; Roshchin, E.; Samsonov, V.; Tarasenkova, O.; Traxler, M.; Ugur, C.; Vznuzdaev, E.; Vznuzdaev, M.
2017-02-01
The CBM RICH detector is an integral component of the future CBM experiment at FAIR, providing efficient electron identification and pion suppression necessary for the measurement of rare dileptonic probes in heavy ion collisions. The RICH design is based on CO2 gas as radiator, a segmented spherical glass focussing mirror with Al+MgF2 reflective coating, and Multianode Photomultipliers for efficient Cherenkov photon detection. Hamamatsu H12700 MAPMTs have recently been selected as photon sensors, following an extensive sensor evaluation, including irradiation tests to ensure sufficient radiation hardness of the MAPMTs. A brief overview of the detector design and concept is given, results on the radiation hardness of the photon sensors are shown, and the development of a FPGA-TDC based readout chain is discussed.
Lee, Roland Y; Huang, Guofu; Porco, Travis C; Chen, Yi-Chun; He, Mingguang; Lin, Shan C
2013-12-01
To evaluate the capability of iris thickness parameters to explain the difference in primary angle-closure glaucoma prevalence among the different racial groups. In this prospective study, 436 patients with open and narrow angles that met inclusion criteria were consecutively recruited from the UCSF general ophthalmology and glaucoma clinics to receive anterior segment optical coherence tomography imaging under standardized dark conditions. Images from 11 patients were removed due to poor visibility of the scleral spurs and the remaining images were analyzed using the Zhongshan Angle Assessment Program to assess the following measurements for the nasal and temporal angle of the anterior chamber: iris thickness at 750 and 2000 μm from the scleral spurs and the maximum iris thickness at middle one third of the iris. Iris thickness parameters were compared among and within the following 5 different racial groups: African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans. In comparing iris parameters among the open-angle racial groups, significant differences were found for nasal iris thickness at 750 and 2000 μm from the scleral spurs in which Chinese Americans displayed the highest mean value (P=0.01, P<0.0001). Among the narrow-angle racial groups, significant difference was found for nasal iris thickness at 2000 μm from the scleral in which Chinese Americans showed the highest mean value (P<0.0001). Significant difference was also found for temporal maximum iris thickness at middle one third of the iris in which African Americans exhibited the highest mean value (P=0.021). Iris thickness was modeled as a function of angle status using linear mixed-effects regression, adjusting for age, sex, pupil diameter, spherical equivalent, ethnicity, and the use of both eyes in patients. The iris thickness difference between the narrow-angle and open-angle groups was significant (P=0.0007). Racial groups that historically showed higher prevalence of primary angle-closure glaucoma possess thicker irides.
1995-06-08
Scientists at Marshall's Adaptive Optics Lab demonstrate the Wave Front Sensor alignment using the Phased Array Mirror Extendible Large Aperture (PAMELA) optics adjustment. The primary objective of the PAMELA project is to develop methods for aligning and controlling adaptive optics segmented mirror systems. These systems can be used to acquire or project light energy. The Next Generation Space Telescope is an example of an energy acquisition system that will employ segmented mirrors. Light projection systems can also be used for power beaming and orbital debris removal. All segmented optical systems must be adjusted to provide maximum performance. PAMELA is an on going project that NASA is utilizing to investigate various methods for maximizing system performance.
Spherical nanoindentation stress–strain curves
Pathak, Siddhartha; Kalidindi, Surya R.
2015-03-24
Although indentation experiments have long been used to measure the hardness and Young's modulus, the utility of this technique in analyzing the complete elastic–plastic response of materials under contact loading has only been realized in the past few years – mostly due to recent advances in testing equipment and analysis protocols. This paper provides a timely review of the recent progress made in this respect in extracting meaningful indentation stress–strain curves from the raw datasets measured in instrumented spherical nanoindentation experiments. These indentation stress–strain curves have produced highly reliable estimates of the indentation modulus and the indentation yield strength inmore » the sample, as well as certain aspects of their post-yield behavior, and have been critically validated through numerical simulations using finite element models as well as direct in situ scanning electron microscopy (SEM) measurements on micro-pillars. Much of this recent progress was made possible through the introduction of a new measure of indentation strain and the development of new protocols to locate the effective zero-point of initial contact between the indenter and the sample in the measured datasets. As a result, this has led to an important key advance in this field where it is now possible to reliably identify and analyze the initial loading segment in the indentation experiments.« less
Goldberg-Zimring, Daniel; Talos, Ion-Florin; Bhagwat, Jui G; Haker, Steven J; Black, Peter M; Zou, Kelly H
2005-04-01
Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics. Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure. Tumor volume range was 22,413-85,189 mm3, and range of number of vertices in triangulated models was 3674-6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 x 10(-5) mm(-1). Summary measures yielded a DSC range of 0.89-0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002-0.0028 (pooled median, 0.0005). 3D shapes of tumors may be approximated by using SH for neurosurgical applications.
Accommodation and age-dependent eye model based on in vivo measurements.
Zapata-Díaz, Juan F; Radhakrishnan, Hema; Charman, W Neil; López-Gil, Norberto
2018-03-21
To develop a flexible model of the average eye that incorporates changes with age and accommodation in all optical parameters, including entrance pupil diameter, under photopic, natural, environmental conditions. We collated retrospective in vivo measurements of all optical parameters, including entrance pupil diameter. Ray-tracing was used to calculate the wavefront aberrations of the eye model as a function of age, stimulus vergence and pupil diameter. These aberrations were used to calculate objective refraction using paraxial curvature matching. This was also done for several stimulus positions to calculate the accommodation response/stimulus curve. The model predicts a hyperopic change in distance refraction as the eye ages (+0.22D every 10 years) between 20 and 65 years. The slope of the accommodation response/stimulus curve was 0.72 for a 25 years-old subject, with little change between 20 and 45 years. A trend to a more negative value of primary spherical aberration as the eye accommodates is predicted for all ages (20-50 years). When accommodation is relaxed, a slight increase in primary spherical aberration (0.008μm every 10 years) between 20 and 65 years is predicted, for an age-dependent entrance pupil diameter ranging between 3.58mm (20 years) and 3.05mm (65 years). Results match reasonably well with studies performed in real eyes, except that spherical aberration is systematically slightly negative as compared with the practical data. The proposed eye model is able to predict changes in objective refraction and accommodation response. It has the potential to be a useful design and testing tool for devices (e.g. intraocular lenses or contact lenses) designed to correct the eye's optical errors. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Analysis of age-dependence of the anterior and posterior cornea with scheimpflug imaging.
Nemeth, Gabor; Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo
2013-05-01
To assess keratometric and higher-order aberrations of the anterior and posterior cornea and their age-related changes. This study investigated one healthy eye of 227 patients (mean age: 55.15 ± 21.2 years; range: 16 to 90 years; 135 right eyes, 92 left eyes). Images were captured from each eye with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) using automatic mode. Keratometric, astigmatism data, and corneal higher-order aberrations were analyzed. With respect to laterality, no deviance was found in any of the parameters (P > .05). Mean refractive error was 0.52 ± 0.23 diopters. The level of astigmatism decreased significantly with advancing age for both the anterior and posterior corneal surfaces (P < .05). The overall root mean square of the higher-order aberration increased continuously with age (r = 0.517; P < .01), which can be explained by the combined effect of the increased in both the anterior and posterior corneal root mean square higher-order aberrations. Of the higher-order aberrations, the constant increase of the primary and secondary spherical aberration with aging (P < .01) is caused by the spherical aberration growth of the anterior surface. Apart from these, only the vertical coma aberration of the posterior surface and the vertical trefoil aberrations of both the anterior and posterior surfaces showed a significantly positive correlation with aging (P < .05). Corneal astigmatism showed a significant decrease with aging. Of the higher-order aberrations, primary and secondary spherical aberrations, vertical coma, and vertical trefoil significantly increase with age, whereas other higher-order aberrations show no correlation with aging. Copyright 2013, SLACK Incorporated.
Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P
2012-03-01
To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre
2016-03-01
Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.
Degradation of experimental composite materials and in vitro wear simulation
NASA Astrophysics Data System (ADS)
Givan, Daniel Allen
2001-12-01
The material, mechanical, and clinical aspects of surface degradation of resin composite dental restorative materials by in vitro wear simulation continues to be an area of active research. To investigate wear mechanisms, a series of experimental resin composites with variable and controlled filler particle shape and loading were studied by in vitro wear simulation. The current investigation utilized a simulation that isolated the wear environment, entrapped high and low modulus debris, and evaluated the process including machine and fluid flow dynamics. The degradation was significantly affected by filler particle shape and less by particle loading. The spherical particle composites demonstrated wear loss profiles suggesting an optimized filler loading may exist. This was also demonstrated by the trends in the mechanical properties. Very little difference in magnitude was noted for the wear of irregular particle composites as a function of particulate size; and as a group they were more wear resistant than spherical particle composites. This was the result of different mechanisms of wear that were correlated with the three-dimensional particle shape. The abrasive effects of the aggregate particles and the polymeric stabilization of the irregular shape versus the destabilization and "plucking" of the spherical particles resulted in an unprotected matrix that accounted for significantly greater wear of spherical composite. A model and analysis was developed to explain the events associated with the progressive material wear loss. The initial phase was explained by fatigue-assisted microcracking and loss of material segments in a zone of high stress immediately beneath a point of high stress contact. The early phase was characterized by the development of a small facet primarily by fatigue-assisted microcracking. Although the translation effects were minimal, some three-body and initial two-body wear events were also present. In the late phases, the abrasive effects of the debris aggregate predominated the wear process. The non-linear rate of wear loss was accelerated as the facet deepened. Physical effects, such as thermal fatigue, and chemical effects were less important but contributed to the degradation process. This study provides new insight into the role(s) of high modulus third body debris in the wear of dental composites.
Loarie, Thomas M; Applegate, David; Kuenne, Christopher B; Choi, Lawrence J; Horowitz, Diane P
2003-01-01
Market segmentation analysis identifies discrete segments of the population whose beliefs are consistent with exhibited behaviors such as purchase choice. This study applies market segmentation analysis to low myopes (-1 to -3 D with less than 1 D cylinder) in their consideration and choice of a refractive surgery procedure to discover opportunities within the market. A quantitative survey based on focus group research was sent to a demographically balanced sample of myopes using contact lenses and/or glasses. A variable reduction process followed by a clustering analysis was used to discover discrete belief-based segments. The resulting segments were validated both analytically and through in-market testing. Discontented individuals who wear contact lenses are the primary target for vision correction surgery. However, 81% of the target group is apprehensive about laser in situ keratomileusis (LASIK). They are nervous about the procedure and strongly desire reversibility and exchangeability. There exists a large untapped opportunity for vision correction surgery within the low myope population. Market segmentation analysis helped determine how to best meet this opportunity through repositioning existing procedures or developing new vision correction technology, and could also be applied to identify opportunities in other vision correction populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakravarti, D.; Hendrix, P.E.; Wilkie, W.L.
1987-01-01
Maturing markets and the accompanying increase in competition, sophistication of customers, and differentiation of products and services have forced companies to focus their marketing efforts on segments in which they can prosper. The experience in these companies has revealed that market segmentation, although simple in concept, is not so easily implemented. It is reasonable to anticipate substantial benefits from additional market segmentation within each of the classes traditionally distinguished in the industry - residential, commercial, and industrial. Segmentation is also likely to prove useful for utilities facing quite different marketing environments, e.g., in terms of demand patterns (number of customers,more » winter- and summer-peaking, etc.), capacity, and degree of regulatory and competitive pressures. Within utilities, those charged with developing and implementing segmentation strategies face some difficult issues. The primary objective of this monograph is to provide some answers to these questions. This monograph is intended to provide utility researchers with a guide to the design and execution of market segmentation research in utility markets. Several composite cases, drawn from actual studies conducted by electric utilities, are used to illustrate the discussion.« less
2015-10-01
tomography images. The CT image densities in Hounsfield units (HU) of the brain were translated into corresponding optical properties (absorption...derived the Hounsfield units and optical properties of brain tissues such as white/gray matter. 13-15 The segmentation software generated an optical map...treatment protocol. Head CT image densities (in Hounsfield Units /HU) are segmented and translated into optical properties of the brain tissue
Amblyopia secondary to iris cyst.
López-Arroquia, T E; Avendaño-Cantos, E M; Mesa-Varona, D; Gálvez-Martínez, J; López-Romero, S; Nuñez-Plascencia, R; González del Valle, F
2014-12-01
A 5 year-old child diagnosed with moderate anisometropic amblyopia secondary to primary cyst of iris pigment epithelium. He was evaluated with ultrasound biomicroscopy (BMU) and optical coherence tomography (OCT) of anterior segment. The OCT, although with some limitations, is a useful tool to study the anterior segment. It is probably more recommendable than BMU in the childhood. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Boucher, Virginie M.; Cangialosi, Daniele; Alegria, Angel; Colmenero, Juan
2011-03-01
The effect of gold nanoparticles on the segmental dynamics, glass transition (Tg) and physical aging of polystyrene (PS) was studied in PS/Gold nanocomposites samples containing 5 and 15 wt.% of 60 nm spherical gold nanoparticles, surface-treated with thiolated-PS. While the segmental dynamics of PS, as assessed by broadband dielectric spectroscopy (BDS), was found to be unchanged in presence of gold nanoparticles, the calorimetric Tg of PS was shown to decrease with increasing the amount of nanoparticles in the samples. Furthermore, the physical aging of PS, monitored by measuring the enthalpy relaxation below Tg by means of DSC, was shown to speed up with increasing the nanoparticles weight fraction, i.e. the amount of PS/Gold interface in the hybrid material. Thus, the main conclusion of our work is that PS molecular mobility and out-of-equilibrium dynamics are decoupled in these nanocomposites. The significant effect of the amount of PS/Gold interface on both the physical aging rate of PS and the calorimetric Tg depression are quantitatively accounted for by a model based on the diffusion of free volume holes towards polymer interfaces, with a diffusion coefficient depending only on the molecular mobility.
Effectiveness of fins formed by dimples in the form of ball segments
NASA Astrophysics Data System (ADS)
Gabdrakhmanov, E. A.; Afonin, G. N.; Glazov, V. S.
2017-11-01
One of the famous ways to improve efficiency of a heat exchanger is associated with the topography of the surfaces being in contact with coolants. So, use of hemispherical dimples leads to progressive growth of the relative heat transfer coefficient compared to increase of the relative resistance coefficient. Usually a plate having the spherical dimple intensifiers for heat transfer is considered as a flat one with embedded cavities. However, such a plate can be also considered as the plate with inbuilt fins which are formed by dimples in the form of ball segments. Given that for the flow of fluid (gas) from left to right, the minimum local heat transfer enhancement occurs in the first (left) half of the dimples, and the maximum falls on the edge of the second (right) half, we obtained an analytical solution describing the temperature distribution along the height of the fin. In the solution we used the Harper-Brown approach. Presented are the results of the calculation of the efficiency of the surface on the parameters of the considered fin and on a known value of the average heat transfer coefficient corresponding to the stage of the fluid flow steady state.
Age of the North Anatolian Fault Segments in the Yalova with U/Th Dating Method by Travertine Data
NASA Astrophysics Data System (ADS)
Selim, Haluk; Ömer Taş, K.
2016-04-01
Travertine occurrences developed along the segments of the North Anatolian Fault (NAF) in the south of Yalova. Travertines outcrop approximately 1 km2 area. These are middle-thick bedded approximately 20-40 m and back-tilted southward or horizontally. Lithology of travertines deposited such as physolite, stalactites-stalagmites, cave pearls, sharp pebble carbonate nodules, spherical-roller-intricate shapes or laminated banded travertine. Geochemical analyses were performed on the six samples of the travertines. X-ray analysis indicates that all samples are entirely composed of low-Mg calcite. Banded travertines with some tubular structures formed by precipitation from rising hot water are best developed near the toes of the large, hanging-wall-derived alluvial fans, whereas phreatic cement preferentially exists in footwall-derived, alluvial-fan conglomerates. The unit developed clarity which is controlled by normal fault as the structural and morphological, relationship with active tectonics. The travertines are a range-front type. U/Th series age dating results indicate that the travertine deposition extends back to 155 ka and yields ages of 60.000 (± 3, 091) to 153.149 (±13,466) from the range-front type travertines.
Hsu, Ying; Kim, Gunhee; Zhang, Qihong; Datta, Poppy; Seo, Seongjin
2017-01-01
Genetic mutations disrupting the structure and function of primary cilia cause various inherited retinal diseases in humans. Bardet-Biedl syndrome (BBS) is a genetically heterogeneous, pleiotropic ciliopathy characterized by retinal degeneration, obesity, postaxial polydactyly, intellectual disability, and genital and renal abnormalities. To gain insight into the mechanisms of retinal degeneration in BBS, we developed a congenital knockout mouse of Bbs8, as well as conditional mouse models in which function of the BBSome (a protein complex that mediates ciliary trafficking) can be temporally inactivated or restored. We demonstrate that BBS mutant mice have defects in retinal outer segment morphogenesis. We further demonstrate that removal of Bbs8 in adult mice affects photoreceptor function and disrupts the structural integrity of the outer segment. Notably, using a mouse model in which a gene trap inhibiting Bbs8 gene expression can be removed by an inducible FLP recombinase, we show that when BBS8 is restored in immature retinas with malformed outer segments, outer segment extension can resume normally and malformed outer segment discs are displaced distally by normal outer segment structures. Over time, the retinas of the rescued mice become morphologically and functionally normal, indicating that there is a window of plasticity when initial retinal outer segment morphogenesis defects can be ameliorated. PMID:29049287
NASA Technical Reports Server (NTRS)
Gersh-Range, Jessica A.; Arnold, William R.; Peck, Mason A.; Stahl, H. Philip
2011-01-01
Since future astrophysics missions require space telescopes with apertures of at least 10 meters, there is a need for on-orbit assembly methods that decouple the size of the primary mirror from the choice of launch vehicle. One option is to connect the segments edgewise using mechanisms analogous to damped springs. To evaluate the feasibility of this approach, a parametric ANSYS model that calculates the mode shapes, natural frequencies, and disturbance response of such a mirror, as well as of the equivalent monolithic mirror, has been developed. This model constructs a mirror using rings of hexagonal segments that are either connected continuously along the edges (to form a monolith) or at discrete locations corresponding to the mechanism locations (to form a segmented mirror). As an example, this paper presents the case of a mirror whose segments are connected edgewise by mechanisms analogous to a set of four collocated single-degree-of-freedom damped springs. The results of a set of parameter studies suggest that such mechanisms can be used to create a 15-m segmented mirror that behaves similarly to a monolith, although fully predicting the segmented mirror performance would require incorporating measured mechanism properties into the model. Keywords: segmented mirror, edgewise connectivity, space telescope
Ocular higher-order aberrations and axial eye growth in young Hong Kong children.
Lau, Jason K; Vincent, Stephen J; Collins, Michael J; Cheung, Sin-Wan; Cho, Pauline
2018-04-30
This retrospective longitudinal analysis aimed to investigate the association between ocular higher-order aberrations (HOAs) and axial eye growth in Hong Kong children. Measures of axial length and ocular HOAs under cycloplegia were obtained annually over a two-year period from 137 subjects aged 8.8 ± 1.4 years with mean spherical equivalent refraction of -2.04 ± 2.38 D. A significant negative association was observed between the RMS of total HOAs and axial eye growth (P = 0.03), after adjusting for other significant predictors of axial length including age, sex and refractive error. Similar negative associations with axial elongation were found for the RMS of spherical aberrations ([Formula: see text] and [Formula: see text] combined) (P = 0.037). Another linear mixed model also showed that greater levels of vertical trefoil [Formula: see text], primary spherical aberration [Formula: see text] and negative oblique trefoil [Formula: see text] were associated with slower axial elongation and longer axial length (all P < 0.05). These findings support the potential role of HOAs, image quality and a vision-dependent mechanism in childhood eye growth.
Tearing of thin spherical shells adhered to equally curved rigid substrates
NASA Astrophysics Data System (ADS)
McMahan, Connor; Lee, Anna; Marthelot, Joel; Reis, Pedro
Lasik (Laser-Assisted in Situ Keratomileusis) eye surgery involves the tearing of the corneal epithelium to remodel the corneal stroma for corrections such as myopia, hyperopia and astigmatism. One issue with this procedure is that during the tearing of the corneal epithelium, if the two propagating cracks coalesce, a flap detaches which could cause significant complications in the recovery of the patient. We seek to gain a predictive physical understanding of this process by performing precision desktop experiments on an analogue model system. First, thin spherical shells of nearly uniform thickness are fabricated by the coating of hemispherical molds with a polymer solution, which upon curing yields an elastic and brittle structure. We then create two notches near the equator of the shell and tear a flap by pulling tangentially to the spherical substrate, towards its pole. The resulting fracture paths are characterized by high-resolution 3D digital scanning. Our primary focus is on establishing how the positive Gaussian curvature of the system affects the path of the crack tip. Our results are directly contrasted against previous studies on systems with zero Gaussian curvature, where films were torn from planar and cylindrical substrates.
Segmentation Control on Crustal Accretion: Insights From the Chile Ridge
NASA Astrophysics Data System (ADS)
Martinez, F.; Karsten, J. L.; Milman, M. S.; Klein, E. M.
2002-12-01
Controls on crustal accretion at mid-ocean ridges include spreading rate and mantle temperature and composition. Less studied is the effect of the segmentation geometry, although it has been known for some time that large offset transforms have significant effects on the extent of melting and lava compositions produced by ridges in their vicinity. The PANORAMA 4 expedition surveyed the Chile Ridge between 36°-43°S in order to examine the effects of ridge segmentation on crustal accretion. This section of the ridge is spreading uniformly at intermediate rates (~53 mm/yr) and rock sampling and regional data indicate a largely uniform mantle composition with no systematic changes in mantle thermal structure. Thus the segmentation geometry is the primary crustal accretion variable. The survey mapped and sampled 19 first order ridge segments and their transform offsets. The ridges range from 130 to 10 km in length with mapped transform offsets from 168 to 19 km. The segments primarily have axial valley morphology, with segments longer than ~65 km typically displaying central highs deepening toward segment ends. Mantle Bouguer anomalies (MBAs) show that these segments also have bulls eye lows associated with the central highs indicating thicker crust than at segment ends. Overall the mapped segments displays a trend of increasing depth and MBA, implying diminishing crustal production, with decreasing segment length and increasing transform offset. We examine the cause of this trend by modeling the mantle flow pattern generated by finite length ridge segments using the Phipps-Morgan and Forsyth (1988) algorithm. The results indicate that at a constant spreading rate mantle upwelling rates are greatest and extend deeper near the segment center, and that for segments that are significantly offset, upwelling rates decrease overall with decreasing segment length. The modeling implies that segmentation itself, even without cooling and lithospheric relief at transforms has a strong influence on mantle advection and therefore on crustal production.
Ng, Vivian G; Mori, Ken; Costa, Ricardo A; Kish, Mitra; Mehran, Roxana; Urata, Hidenori; Saku, Keijiro; Stone, Gregg W; Lansky, Alexandra J
2016-03-15
Women with AMI may have worse outcomes than men. However, it is unclear if this is related to differences in treatment, treatment effect or gender specific factors. We sought to determine whether primary percutaneous intervention (PCI) has a differential impact on infarct size, myocardial perfusion and ST segment resolution in men and women with acute myocardial infarction (AMI). A total of 501 AMI patients were prospectively enrolled in the EMERALD study and underwent PCI with or without distal protection. Post hoc gender subset analysis was performed. 501 patients (108 women, 393 men) with ST-segment elevation AMI presenting within 6h underwent primary (or rescue) PCI with stenting and a distal protection device. Women were older, had more hypertension, less prior AMI, smaller BSA, and smaller vessel size, but had similar rates of diabetes (30% versus 20.2%, p=0.87), LAD infarct, and time-to-reperfusion compared to men. Women more frequently had complete ST-resolution (>70%) at 30days (72.8% versus 59.8%, p=0.02), and smaller infarct size compared to males (12.2±19.6% versus 18.4±18.5%, p=0.006). At 6months, TLR (6.9% versus 5.2%) and MACE (11.4% versus 10.3%) were similar for women and men. Despite worse comorbidities, women with AMI treated with primary PCI with stenting showed similar early and midterm outcomes compared to men. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Breuckmann, F; Remberg, F; Böse, D; Lichtenberg, M; Kümpers, P; Pavenstädt, H; Waltenberger, J; Fischer, D
2016-03-01
This study aimed to analyze guideline adherence in the timing of invasive management for myocardial infarction without persistent ST-segment elevation (NSTEMI) in two exemplary German centers, comparing an urban university maximum care facility and a rural regional primary care facility. All patients diagnosed as having NSTEMI during 2013 were retrospectively enrolled in two centers: (1) site I, a maximum care center in an urban university setting, and (b) site II, a primary care center in a rural regional care setting. Data acquisition included time intervals from admission to invasive management, risk criteria, rate of intervention, and medical therapy. The median time from admission to coronary angiography was 12.0 h (site I) or 17.5 h (site II; p = 0.17). Guideline-adherent timing was achieved in 88.1 % (site I) or 82.9 % (site II; p = 0.18) of cases. Intervention rates were high in both sites (site I-75.5 % vs. site II-75.3 %; p = 0.85). Adherence to recommendations of medical therapy was high and comparable between the two sites. In NSTEMI or high-risk acute coronary syndromes without persistent ST-segment elevation, guideline-adherent timing of invasive management was achieved in about 85 % of cases, and was comparable between urban maximum and rural primary care settings. Validation by the German Chest Pain Unit Registry including outcome analysis is required.
Brain tumor segmentation in multi-spectral MRI using convolutional neural networks (CNN).
Iqbal, Sajid; Ghani, M Usman; Saba, Tanzila; Rehman, Amjad
2018-04-01
A tumor could be found in any area of the brain and could be of any size, shape, and contrast. There may exist multiple tumors of different types in a human brain at the same time. Accurate tumor area segmentation is considered primary step for treatment of brain tumors. Deep Learning is a set of promising techniques that could provide better results as compared to nondeep learning techniques for segmenting timorous part inside a brain. This article presents a deep convolutional neural network (CNN) to segment brain tumors in MRIs. The proposed network uses BRATS segmentation challenge dataset which is composed of images obtained through four different modalities. Accordingly, we present an extended version of existing network to solve segmentation problem. The network architecture consists of multiple neural network layers connected in sequential order with the feeding of Convolutional feature maps at the peer level. Experimental results on BRATS 2015 benchmark data thus show the usability of the proposed approach and its superiority over the other approaches in this area of research. © 2018 Wiley Periodicals, Inc.
Audio-guided audiovisual data segmentation, indexing, and retrieval
NASA Astrophysics Data System (ADS)
Zhang, Tong; Kuo, C.-C. Jay
1998-12-01
While current approaches for video segmentation and indexing are mostly focused on visual information, audio signals may actually play a primary role in video content parsing. In this paper, we present an approach for automatic segmentation, indexing, and retrieval of audiovisual data, based on audio content analysis. The accompanying audio signal of audiovisual data is first segmented and classified into basic types, i.e., speech, music, environmental sound, and silence. This coarse-level segmentation and indexing step is based upon morphological and statistical analysis of several short-term features of the audio signals. Then, environmental sounds are classified into finer classes, such as applause, explosions, bird sounds, etc. This fine-level classification and indexing step is based upon time- frequency analysis of audio signals and the use of the hidden Markov model as the classifier. On top of this archiving scheme, an audiovisual data retrieval system is proposed. Experimental results show that the proposed approach has an accuracy rate higher than 90 percent for the coarse-level classification, and higher than 85 percent for the fine-level classification. Examples of audiovisual data segmentation and retrieval are also provided.
Influence of eye micromotions on spatially resolved refractometry
NASA Astrophysics Data System (ADS)
Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.
2001-01-01
The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.
Sankar, Sathish; Upadhyay, Mohita; Ramamurthy, Mageshbabu; Vadivel, Kumaran; Sagadevan, Kalaiselvan; Nandagopal, Balaji; Vivekanandan, Perumal; Sridharan, Gopalan
2015-01-01
Hantaviruses are important emerging zoonotic pathogens. The current understanding of hantavirus evolution is complicated by the lack of consensus on co-divergence of hantaviruses with their animal hosts. In addition, hantaviruses have long-term associations with their reservoir hosts. Analyzing the relative abundance of dinucleotides may shed new light on hantavirus evolution. We studied the relative abundance of dinucleotides and the evolutionary pressures shaping different hantavirus segments. A total of 118 sequences were analyzed; this includes 51 sequences of the S segment, 43 sequences of the M segment and 23 sequences of the L segment. The relative abundance of dinucleotides, effective codon number (ENC), codon usage biases were analyzed. Standard methods were used to investigate the relative roles of mutational pressure and translational selection on the three hantavirus segments. All three segments of hantaviruses are CpG depleted. Mutational pressure is the predominant evolutionary force leading to CpG depletion among hantaviruses. Interestingly, the S segment of hantaviruses is GpU depleted and in contrast to CpG depletion, the depletion of GpU dinucleotides from the S segment is driven by translational selection. Our findings also suggest that mutational pressure is the primary evolutionary pressure acting on the S and the M segments of hantaviruses. While translational selection plays a key role in shaping the evolution of the L segment. Our findings highlight how different evolutionary pressures may contribute disproportionally to the evolution of the three hantavirus segments. These findings provide new insights on the current understanding of hantavirus evolution. There is a dichotomy among evolutionary pressures shaping a) the relative abundance of different dinucleotides in hantavirus genomes b) the evolution of the three hantavirus segments.
NASA Astrophysics Data System (ADS)
Shurshakov, Vyacheslav; Nikolaev, Igor; Kartsev, Ivan; Tolochek, Raisa; Lyagushin, Vladimir
The tissue-equivalent spherical phantom (32 kg mass, 35 cm diameter and 10 cm central spherical cave) made in Russia has been used on board the ISS in Matroshka-R experiment for more than 10 years. Both passive and active space radiation detectors can be located inside the phantom and on its surface. Due to the specially chosen phantom shape and size, the chord length distributions of the detector locations are attributed to self-shielding properties of the critical organs in a human body. Originally the spherical phantom was installed in the star board crew cabin of the ISS Service Module, then in the Piers-1, MIM-2, and MIM-1 modules of the ISS Russian segment, and finally in JAXA Kibo module. Total duration of the detector exposure is more than 2000 days in 9 sessions of the space experiment. In the first phase of the experiment with the spherical phantom the dose measurements were realized with only passive detectors (thermoluminescent and solid state track detectors). The detectors are placed inside the phantom along the axes of 20 containers and on the phantom outer surface in 32 pockets of the phantom jacket. After each session the passive detectors are returned to the ground. The results obtained show the dose difference on the phantom surface as much as a factor of 2, the highest dose being usually observed close to the outer wall of the compartment, and the lowest dose being in the opposite location along the phantom diameter. However, because of the ISS module shielding properties an inverse dose distribution in a human body can be observed when the dose rate maximum is closer to the geometrical center of the module. Maximum dose rate measured in the phantom is obviously due to the action of two radiation sources, namely, galactic cosmic rays (GCR) and Earth’ radiation belts. Minimum dose rate is produced mainly by the strongly penetrating GCR particles and is mostly observed behind more than 5 g/cm2 tissue shielding. Critical organ doses, mean-tissue and effective doses of a crew member in the ISS compartments are also estimated with the spherical phantom data. The estimated effective dose rate is found to be from 10 % to 15 % lower than the averaged dose on the phantom surface as dependent on the attitude of the critical organs. If compared with the anthropomorphic phantom Rando used inside and outside the ISS earlier, the Matroshka-R space experiment spherical phantom has lower mass, smaller size, and requires less crew time for the detector installation/retrieval; its tissue-equivalent properties are closer to the standard human body tissue than the Rando-phantom material. New sessions with the two tissue-equivalent phantoms are of great interest. Development of modified passive and active detector sets is in progress for the future ISS expeditions. Both the spherical and Rando-type phantoms proved their effectiveness to measure the critical organ doses and effective doses in-flight and if supplied with modernized dosimeters can be recommended for future exploratory manned missions to monitor continuously the crew exposure to space radiation.
A patient-specific segmentation framework for longitudinal MR images of traumatic brain injury
NASA Astrophysics Data System (ADS)
Wang, Bo; Prastawa, Marcel; Irimia, Andrei; Chambers, Micah C.; Vespa, Paul M.; Van Horn, John D.; Gerig, Guido
2012-02-01
Traumatic brain injury (TBI) is a major cause of death and disability worldwide. Robust, reproducible segmentations of MR images with TBI are crucial for quantitative analysis of recovery and treatment efficacy. However, this is a significant challenge due to severe anatomy changes caused by edema (swelling), bleeding, tissue deformation, skull fracture, and other effects related to head injury. In this paper, we introduce a multi-modal image segmentation framework for longitudinal TBI images. The framework is initialized through manual input of primary lesion sites at each time point, which are then refined by a joint approach composed of Bayesian segmentation and construction of a personalized atlas. The personalized atlas construction estimates the average of the posteriors of the Bayesian segmentation at each time point and warps the average back to each time point to provide the updated priors for Bayesian segmentation. The difference between our approach and segmenting longitudinal images independently is that we use the information from all time points to improve the segmentations. Given a manual initialization, our framework automatically segments healthy structures (white matter, grey matter, cerebrospinal fluid) as well as different lesions such as hemorrhagic lesions and edema. Our framework can handle different sets of modalities at each time point, which provides flexibility in analyzing clinical scans. We show results on three subjects with acute baseline scans and chronic follow-up scans. The results demonstrate that joint analysis of all the points yields improved segmentation compared to independent analysis of the two time points.
Prevalence of Incidental Clinoid Segment Saccular Aneurysms.
Revilla-Pacheco, Francisco; Escalante-Seyffert, María Cecilia; Herrada-Pineda, Tenoch; Manrique-Guzman, Salvador; Perez-Zuniga, Irma; Rangel-Suarez, Sergio; Rubalcava-Ortega, Johnatan; Loyo-Varela, Mauro
2018-04-12
Clinoid segment aneurysms are cerebral vascular lesions recently described in the neurosurgical literature. They arise from the clinoid segment of the internal carotid artery, which is the segment limited rostrally by the dural carotid ring and caudally, by the carotid-oculomotor membrane. Even although clinoid segment aneurysms represent a common incidental finding in magnetic resonance studies, its prevalence has not been yet reported. To determine the prevalence of incidental clinoid segment saccular aneurysms diagnosed by magnetic resonance imaging as well as their anatomic architecture and their association with smoking, arterial hypertension, age, and sex of patients. A total of 500 patients were prospectively studied with magnetic resonance imaging time-of-flight sequence and angioresonance with contrast material, to search for incidental saccular intracranial aneurysms. The site of primary interest was the clinoid segment, but the presence of aneurysms in any other location was determined for comparison. The relation among the presence of clinoid segment aneurysms, demographic factors, and secondary diagnosis of arterial hypertension, smoking, and other vascular/neoplastic cerebral lesions was analyzed. We found a global prevalence of incidental aneurysms of 7% (95% confidence interval, 5-9), with a prevalence of clinoid segment aneurysms of 3% (95% confidence interval, 2-4). Univariate logistic regression analysis showed a statistically significant relationship among incidental aneurysms, systemic arterial hypertension (P = 0.000), and smoking (P = 0.004). In the studied population, incidental clinoid segment aneurysms constitute the variety with highest prevalence. Copyright © 2018 Elsevier Inc. All rights reserved.
2009-01-01
Abstract Collaborative care models for depression in primary care are effective and cost-effective, but difficult to spread to new sites. Translating Initiatives for Depression into Effective Solutions (TIDES) is an initiative to promote evidence-based collaborative care in the U.S. Veterans Health Administration (VHA). Social marketing applies marketing techniques to promote positive behavior change. Described in this paper, TIDES used a social marketing approach to foster national spread of collaborative care models. TIDES social marketing approach The approach relied on a sequential model of behavior change and explicit attention to audience segmentation. Segments included VHA national leadership, Veterans Integrated Service Network (VISN) regional leadership, facility managers, frontline providers, and veterans. TIDES communications, materials and messages targeted each segment, guided by an overall marketing plan. Results Depression collaborative care based on the TIDES model was adopted by VHA as part of the new Primary Care Mental Health Initiative and associated policies. It is currently in use in more than 50 primary care practices across the United States, and continues to spread, suggesting success for its social marketing-based dissemination strategy. Discussion and conclusion Development, execution and evaluation of the TIDES marketing effort shows that social marketing is a promising approach for promoting implementation of evidence-based interventions in integrated healthcare systems. PMID:19785754
Overview and status of the Giant Magellan Telescope Project
NASA Astrophysics Data System (ADS)
McCarthy, Patrick J.; Fanson, James; Bernstein, Rebecca; Ashby, David; Bigelow, Bruce; Boyadjian, Nune; Bouchez, Antonin; Chauvin, Eric; Donoso, Eduardo; Filgueira, Jose; Goodrich, Robert; Groark, Frank; Jacoby, George; Pearce, Eric
2016-08-01
The Giant Magellan Telescope Project is in the construction phase. Production of the primary mirror segments is underway with four of the seven required 8.4m mirrors at various stages of completion and materials purchased for segments five and six. Development of the infrastructure at the GMT site at Las Campanas is nearing completion. Power, water, and data connections sufficient to support the construction of the telescope and enclosure are in place and roads to the summit have been widened and graded to support transportation of large and heavy loads. Construction pads for the support buildings have been graded and the construction residence is being installed. A small number of issues need to be resolved before the final design of the telescope structure and enclosure can proceed and the GMT team is collecting the required inputs to the decision making process. Prototyping activities targeted at the active and adaptive optics systems are allowing us to finalize designs before large scale production of components begins. Our technically driven schedule calls for the telescope to be assembled on site in 2022 and to be ready to receive a subset of the primary and secondary mirror optics late in the year. The end date for the project is coupled to the delivery of the final primary mirror segments and the adaptive secondary mirrors that support adaptive optics operations.
Ultralightweight Space Deployable Primary Reflector Demonstrator
NASA Technical Reports Server (NTRS)
Montgomery, Edward E., IV; Zeiders, Glenn W.; Smith, W. Scott (Technical Monitor)
2002-01-01
A concept has been developed and analyzed and several generational prototypes built for a gossamer-class deployable truss for a mirror or reflector with many smaller precisely-figured solid elements attached will, for at least the next several decades, minimize the mass of a large primary mirror assembly while still providing the high image quality essential for planet-finding and cosmological astronomical missions. Primary mirror segments are mounted in turn on ultralightweight thermally-formed plastic panels that hold clusters of mirror segments in rigid arrays whose tip/tilt and piston would be corrected over the scale of the plastic panels by the control segments. Prototype panels developed under this program are 45 cm wide and fabricated from commercially available Kaplan sheets. A three-strut octahedral tensegrity is the basis for the overall support structure. Each fundamental is composed of two such octahedrons, rotated oppositely about a common triangular face. Adjacent modules are joined at the nodes of the upper and lower triangles to form a deployable structure that could be made arbitrarily large. A seven-module dowel-and-wire prototype has been constructed. Deployment techniques based on the use of collapsing toggled struts with diagonal tensional elements allows an assembly of tensegrities to be fully collapsed and redeployed. The prototype designs will be described and results of a test program for measuring strength and deformation will be presented.
Habermeyer, Peter; Magosch, Petra; Weiß, Christel; Hawi, Nael; Lichtenberg, Sven; Tauber, Mark; Ipach, Bastian
2017-12-01
The purpose of this study was to characterize the pathologic changes of the osteoarthritic humeral head. The study included 55 patients with primary osteoarthritis who underwent anatomic shoulder arthroplasty. Several radiologic parameters (radiography, magnetic resonance imaging) were assessed. Humeral head deformity in the transverse plane and humeral cartilage erosion in the coronal plane were chosen for photographic measurements from the resected humeral heads. In the coronal plane, 82% of patients presented with an aspherical humeral head shape with a significantly longer caudal osteophyte. In the transverse plane, 50% of all patients showed a decentered apex. Patients with an aspherical humeral head shape in the transverse plane showed an aspherical humeral head shape in the coronal plane in 94% and a significantly longer osteophyte than patients with spherical humeral head shape, showing a 3-dimensional deformity of the humeral head during progression of primary osteoarthritis. Patients with an osteophyte length between 7 and 12 mm were associated with a glenoid type B2 in 30% and a decentered apex in the transverse plane in 38%. Patients with a humeral osteophyte longer than 13 mm were significantly more frequently associated with a type B2 glenoid (71%; P < .0001) and a decentered apex in the transverse plane in 52%. It seems that the progression of primary osteoarthritis of the glenohumeral joint is characterized by an increasing 3-dimensional deformity of the humeral head related to the glenoid morphology. We therefore propose an extended Samilson-Prieto classification with type A (spherical) and type B (aspherical) and grade I-IV osteophytes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Method of artificial DNA splicing by directed ligation (SDL).
Lebedenko, E N; Birikh, K R; Plutalov, O V; Berlin YuA
1991-01-01
An approach to directed genetic recombination in vitro has been devised, which allows for joining together, in a predetermined way, a series of DNA segments to give a precisely spliced polynucleotide sequence (DNA splicing by directed ligation, SDL). The approach makes use of amplification, by means of several polymerase chain reactions (PCR), of a chosen set of DNA segments. Primers for the amplifications contain recognition sites of the class IIS restriction endonucleases, which transform blunt ends of the amplification products into protruding ends of unique primary structures, the ends to be used for joining segments together being mutually complementary. Ligation of the mixture of the segments so synthesized gives the desired sequence in an unambiguous way. The suggested approach has been exemplified by the synthesis of a totally processed (intronless) gene encoding human mature interleukin-1 alpha. Images PMID:1662363
Emoto, Akira; Fukuda, Takashi
2013-02-20
For Fourier transform holography, an effective random phase distribution with randomly displaced phase segments is proposed for obtaining a smooth finite optical intensity distribution in the Fourier transform plane. Since unitary phase segments are randomly distributed in-plane, the blanks give various spatial frequency components to an image, and thus smooth the spectrum. Moreover, by randomly changing the phase segment size, spike generation from the unitary phase segment size in the spectrum can be reduced significantly. As a result, a smooth spectrum including sidebands can be formed at a relatively narrow extent. The proposed phase distribution sustains the primary functions of a random phase mask for holographic-data recording and reconstruction. Therefore, this distribution is expected to find applications in high-density holographic memory systems, replacing conventional random phase mask patterns.
Semantic Segmentation of Building Elements Using Point Cloud Hashing
NASA Astrophysics Data System (ADS)
Chizhova, M.; Gurianov, A.; Hess, M.; Luhmann, T.; Brunn, A.; Stilla, U.
2018-05-01
For the interpretation of point clouds, the semantic definition of extracted segments from point clouds or images is a common problem. Usually, the semantic of geometrical pre-segmented point cloud elements are determined using probabilistic networks and scene databases. The proposed semantic segmentation method is based on the psychological human interpretation of geometric objects, especially on fundamental rules of primary comprehension. Starting from these rules the buildings could be quite well and simply classified by a human operator (e.g. architect) into different building types and structural elements (dome, nave, transept etc.), including particular building parts which are visually detected. The key part of the procedure is a novel method based on hashing where point cloud projections are transformed into binary pixel representations. A segmentation approach released on the example of classical Orthodox churches is suitable for other buildings and objects characterized through a particular typology in its construction (e.g. industrial objects in standardized enviroments with strict component design allowing clear semantic modelling).
Young, Lynne E; Murray, Jackie
2011-01-01
Many patients experiencing ST segment elevation myocardial infarction (STEMI) are currently treated with primary percutaneous intervention (PCI). This relatively new procedure has reduced the time patients with the diagnosis of STEMI spend in hospital. In this literature review we explore patients' perceptions of their experience of receiving primary percutaneous intervention (PCI) as a treatment for STEMI. We critiqued and graded for relevance 10 papers that included original research and other sources. Key findings indicate that there is considerable variability in how patients treated for STEMI perceive the experience of PCI. Further, there is a misalignment between some patients' perceptions and health professionals' perceptions of this experience related to the event as well as the language used to speak of it. Thus, we recommend that nurses assess patients' perception of the experience and patients' health literacy level, then tailor the content and language of patient and family education to ensure an effective educative intervention.
Herman, Emily K; Greninger, Alexander L; Visvesvara, Govinda S; Marciano-Cabral, Francine; Dacks, Joel B; Chiu, Charles Y
2013-01-01
Naegleria fowleri is a unicellular eukaryote causing primary amoebic meningoencephalitis, a neuropathic disease killing 99% of those infected, usually within 7-14 days. Naegleria fowleri is found globally in regions including the US and Australia. The genome of the related nonpathogenic species Naegleria gruberi has been sequenced, but the genetic basis for N. fowleri pathogenicity is unclear. To generate such insight, we sequenced and assembled the mitochondrial genome and a 60-kb segment of nuclear genome from N. fowleri. The mitochondrial genome is highly similar to its counterpart in N. gruberi in gene complement and organization, while distinct lack of synteny is observed for the nuclear segments. Even in this short (60-kb) segment, we identified examples of potential factors for pathogenesis, including ten novel N. fowleri-specific genes. We also identified a homolog of cathepsin B; proteases proposed to be involved in the pathogenesis of diverse eukaryotic pathogens, including N. fowleri. Finally, we demonstrate a likely case of horizontal gene transfer between N. fowleri and two unrelated amoebae, one of which causes granulomatous amoebic encephalitis. This initial look into the N. fowleri nuclear genome has revealed several examples of potential pathogenesis factors, improving our understanding of a neglected pathogen of increasing global importance. © 2013 The Author(s) Journal of Eukaryotic Microbiology © 2013 International Society of Protistologists.
Danchin, Nicolas; Dos Santos Teixeira, Nelson; Puymirat, Etienne
2014-08-01
All guidelines recommend primary percutaneous coronary intervention as the default strategy for achieving reperfusion in ST-segment elevation myocardial infarction patients. These recommendations are based upon randomized trials which compared primary percutaneous coronary intervention with stand-alone intravenous fibrinolysis. Since the time these trials were performed, however, it has been shown in further trials that use of rescue percutaneous coronary intervention in patients without signs of reperfusion after lysis, and routine coronary angiography within 24 h of the administration of lysis for all other patients, substantially improved the results of intravenous fibrinolytic treatment. This has led to proposing the pharmaco-invasive strategy as an alternative to primary percutaneous coronary intervention. Actually, it is not uncommon that circumstances prevent performing primary percutaneous coronary intervention within the recommended time limits set by the guidelines. In such cases, using a pharmaco-invasive strategy may constitute a valid alternative. Both the STREAM randomized trial and real-world experience, in particular the long-term results from the FAST-MI registry, suggest that the pharmaco-invasive strategy, when used in an appropriate population, compares favorably with primary percutaneous coronary intervention. Therefore, implementing a pharmaco-invasive strategy protocol may be an important complement to compensate for potential weaknesses in ST-segment elevation myocardial infarction networks. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Phased Array Mirror Extendible Large Aperture (PAMELA) Optics Adjustment
NASA Technical Reports Server (NTRS)
1995-01-01
Scientists at Marshall's Adaptive Optics Lab demonstrate the Wave Front Sensor alignment using the Phased Array Mirror Extendible Large Aperture (PAMELA) optics adjustment. The primary objective of the PAMELA project is to develop methods for aligning and controlling adaptive optics segmented mirror systems. These systems can be used to acquire or project light energy. The Next Generation Space Telescope is an example of an energy acquisition system that will employ segmented mirrors. Light projection systems can also be used for power beaming and orbital debris removal. All segmented optical systems must be adjusted to provide maximum performance. PAMELA is an on going project that NASA is utilizing to investigate various methods for maximizing system performance.
JWST Pathfinder Telescope Integration
NASA Technical Reports Server (NTRS)
Matthews, Gary W.; Kennard, Scott H.; Broccolo, Ronald T.; Ellis, James M.; Daly, Elizabeth A.; Hahn, Walter G.; Amon, John N.; Mt. Pleasant, Stephen M.; Texter, Scott; Atkinson, Charles B.;
2015-01-01
The James Webb Space Telescope (JWST) is a 6.5m, segmented, IR telescope that will explore the first light of the universe after the big bang. In 2014, a major risk reduction effort related to the Alignment, Integration, and Test (AI&T) of the segmented telescope was completed. The Pathfinder telescope includes two Primary Mirror Segment Assemblies (PMSA's) and the Secondary Mirror Assembly (SMA) onto a flight-like composite telescope backplane. This pathfinder allowed the JWST team to assess the alignment process and to better understand the various error sources that need to be accommodated in the flight build. The successful completion of the Pathfinder Telescope provides a final integration roadmap for the flight operations that will start in August 2015.
By the Dozen: NASA's James Webb Space Telescope Mirrors
2016-01-03
Caption: One dozen (out of 18) flight mirror segments that make up the primary mirror on NASA's James Webb Space Telescope have been installed at NASA's Goddard Space Flight Center. Credits: NASA/Chris Gunn More: Since December 2015, the team of scientists and engineers have been working tirelessly to install all the primary mirror segments onto the telescope structure in the large clean room at NASA's Goddard Space Flight Center in Greenbelt, Maryland. The twelfth mirror was installed on January 2, 2016. "This milestone signifies that all of the hexagonal shaped mirrors on the fixed central section of the telescope structure are installed and only the 3 mirrors on each wing are left for installation," said Lee Feinberg, NASA's Optical Telescope Element Manager at NASA Goddard. "The incredibly skilled and dedicated team assembling the telescope continues to find ways to do things faster and more efficiently." Each hexagonal-shaped segment measures just over 4.2 feet (1.3 meters) across and weighs approximately 88 pounds (40 kilograms). After being pieced together, the 18 primary mirror segments will work together as one large 21.3-foot (6.5-meter) mirror. The primary mirror will unfold and adjust to shape after launch. The mirrors are made of ultra-lightweight beryllium. The mirrors are placed on the telescope's backplane using a robotic arm, guided by engineers. The full installation is expected to be completed in a few months. The mirrors were built by Ball Aerospace & Technologies Corp., Boulder, Colorado. Ball is the principal subcontractor to Northrop Grumman for the optical technology and lightweight mirror system. The installation of the mirrors onto the telescope structure is performed by Harris Corporation of Rochester, New York. Harris Corporation leads integration and testing for the telescope. While the mirror assembly is a very significant milestone, there are many more steps involved in assembling the Webb telescope. The primary mirror and the tennis-court-sized sunshield are the largest and most visible components of the Webb telescope. However, there are four smaller components that are less visible, yet critical. The instruments that will fly aboard Webb - cameras and spectrographs with detectors able to record extremely faint signals — are part of the Integrated Science Instrument Module (ISIM), which is currently undergoing its final cryogenic vacuum test and will be integrated with the mirror later this year.
By the Dozen: NASA's James Webb Space Telescope Mirrors
2016-01-03
A view of the one dozen (out of 18) flight mirror segments that make up the primary mirror on NASA's James Webb Space Telescope have been installed at NASA's Goddard Space Flight Center. Credits: NASA/Chris Gunn More: Since December 2015, the team of scientists and engineers have been working tirelessly to install all the primary mirror segments onto the telescope structure in the large clean room at NASA's Goddard Space Flight Center in Greenbelt, Maryland. The twelfth mirror was installed on January 2, 2016. "This milestone signifies that all of the hexagonal shaped mirrors on the fixed central section of the telescope structure are installed and only the 3 mirrors on each wing are left for installation," said Lee Feinberg, NASA's Optical Telescope Element Manager at NASA Goddard. "The incredibly skilled and dedicated team assembling the telescope continues to find ways to do things faster and more efficiently." Each hexagonal-shaped segment measures just over 4.2 feet (1.3 meters) across and weighs approximately 88 pounds (40 kilograms). After being pieced together, the 18 primary mirror segments will work together as one large 21.3-foot (6.5-meter) mirror. The primary mirror will unfold and adjust to shape after launch. The mirrors are made of ultra-lightweight beryllium. The mirrors are placed on the telescope's backplane using a robotic arm, guided by engineers. The full installation is expected to be completed in a few months. The mirrors were built by Ball Aerospace & Technologies Corp., Boulder, Colorado. Ball is the principal subcontractor to Northrop Grumman for the optical technology and lightweight mirror system. The installation of the mirrors onto the telescope structure is performed by Harris Corporation of Rochester, New York. Harris Corporation leads integration and testing for the telescope. While the mirror assembly is a very significant milestone, there are many more steps involved in assembling the Webb telescope. The primary mirror and the tennis-court-sized sunshield are the largest and most visible components of the Webb telescope. However, there are four smaller components that are less visible, yet critical. The instruments that will fly aboard Webb - cameras and spectrographs with detectors able to record extremely faint signals — are part of the Integrated Science Instrument Module (ISIM), which is currently undergoing its final cryogenic vacuum test and will be integrated with the mirror later this year.
High-intensity erotic visual stimuli de-activate the primary visual cortex in women.
Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert
2012-06-01
The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.
Rashid, Mohammed K; Guron, Nita; Bernick, Jordan; Wells, George A; Blondeau, Melissa; Chong, Aun-Yeong; Dick, Alexander; Froeschl, Michael P V; Glover, Chris A; Hibbert, Benjamin; Labinaz, Marino; Marquis, Jean-François; Osborne, Christina; So, Derek Y; Le May, Michel R
2016-10-10
This study investigated the safety and efficacy of a pharmacoinvasive strategy compared with a primary percutaneous coronary intervention (PCI) strategy for ST-segment elevation myocardial infarction (STEMI) in the context of a real-world system. Primary PCI continues to be the optimal reperfusion therapy; however, in areas where PCI centers are not readily available, a pharmacoinvasive strategy has been proposed. The University of Ottawa Heart Institute regional STEMI system provides a primary PCI strategy for patients presenting within a 90-km radius from the PCI center, and a pharmacoinvasive strategy for patients outside this limit. We included all confirmed STEMI patients between April 2009 and May 2011. The primary efficacy outcome was a composite of mortality, reinfarction, or stroke and the primary safety outcome was major bleeding. We identified 236 and 980 consecutive patients enrolled in pharmacoinvasive and primary PCI strategies, respectively. The median door-to-needle time was 31 min in the pharmacoinvasive group and the median door-to-balloon time was 95 min in the primary PCI group. In a multivariable model, there was no significant difference in the primary efficacy outcome (odds ratio: 1.54; p = 0.21); however, the propensity for more bleeding with a pharmacoinvasive strategy approached statistical significance (odds ratio: 2.02; p = 0.08). Within the context of a STEMI system, a pharmacoinvasive strategy was associated with similar rates of the composite of mortality, reinfarction, or stroke as compared with a primary PCI strategy; however, there was a propensity for more bleeding with a pharmacoinvasive strategy. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Variation in ejecta size with ejection velocity
NASA Technical Reports Server (NTRS)
Vickery, Ann M.
1987-01-01
The sizes and ranges of over 25,000 secondary craters around twelve large primaries on three different planets were measured and used to infer the size-velocity distribution of that portion of the primary crater ejecta that produced the secondaries. The ballistic equation for spherical bodies was used to convert the ranges to velocities, and the velocities and crater sizes were used in the appropriate Schmidt-Holsapple scaling relation of estimate ejecta sizes, and the velocity exponent was determined. The latter are generally between -1 and -13, with an average value of about -1.9. Problems with data collection made it impossible to determine a simple, unique relation between size and velocity.
Pasupathy, Sivabaskari; Tavella, Rosanna; Grover, Suchi; Raman, Betty; Procter, Nathan E K; Du, Yang Timothy; Mahadavan, Gnanadevan; Stafford, Irene; Heresztyn, Tamila; Holmes, Andrew; Zeitz, Christopher; Arstall, Margaret; Selvanayagam, Joseph; Horowitz, John D; Beltrame, John F
2017-09-05
Contemporary ST-segment-elevation myocardial infarction management involves primary percutaneous coronary intervention, with ongoing studies focusing on infarct size reduction using ancillary therapies. N-acetylcysteine (NAC) is an antioxidant with reactive oxygen species scavenging properties that also potentiates the effects of nitroglycerin and thus represents a potentially beneficial ancillary therapy in primary percutaneous coronary intervention. The NACIAM trial (N-acetylcysteine in Acute Myocardial Infarction) examined the effects of NAC on infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. This randomized, double-blind, placebo-controlled, multicenter study evaluated the effects of intravenous high-dose NAC (29 g over 2 days) with background low-dose nitroglycerin (7.2 mg over 2 days) on early cardiac magnetic resonance imaging-assessed infarct size. Secondary end points included cardiac magnetic resonance-determined myocardial salvage and creatine kinase kinetics. Of 112 randomized patients with ST-segment-elevation myocardial infarction, 75 (37 in NAC group, 38 in placebo group) underwent early cardiac magnetic resonance imaging. Median duration of ischemia pretreatment was 2.4 hours. With background nitroglycerin infusion administered to all patients, those randomized to NAC exhibited an absolute 5.5% reduction in cardiac magnetic resonance-assessed infarct size relative to placebo (median, 11.0%; [interquartile range 4.1, 16.3] versus 16.5%; [interquartile range 10.7, 24.2]; P =0.02). Myocardial salvage was approximately doubled in the NAC group (60%; interquartile range, 37-79) compared with placebo (27%; interquartile range, 14-42; P <0.01) and median creatine kinase areas under the curve were 22 000 and 38 000 IU·h in the NAC and placebo groups, respectively ( P =0.08). High-dose intravenous NAC administered with low-dose intravenous nitroglycerin is associated with reduced infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. A larger study is required to assess the impact of this therapy on clinical cardiac outcomes. Australian New Zealand Clinical Trials Registry. URL: http://www.anzctr.org.au/. Unique identifier: 12610000280000. © 2017 American Heart Association, Inc.
Giri, Maria Grazia; Cavedon, Carlo; Mazzarotto, Renzo; Ferdeghini, Marco
2016-05-01
The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracy was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10-37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This "calibration curve" was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giri, Maria Grazia, E-mail: mariagrazia.giri@ospedaleuniverona.it; Cavedon, Carlo; Mazzarotto, Renzo
Purpose: The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robustness. Methods: The DPM model belongs to the class of the Bayesian nonparametric models and uses the Dirichlet process prior for flexible nonparametric mixture modeling, without any preliminary choice of the number of mixture components. The DPM algorithm implemented in the statistical software package R was used in this work. The contouring accuracymore » was evaluated on several image data sets: on an IEC phantom (spherical inserts with diameter in the range 10–37 mm) acquired by a Philips Gemini Big Bore PET-CT scanner, using 9 different target-to-background ratios (TBRs) from 2.5 to 70; on a digital phantom simulating spherical/uniform lesions and tumors, irregular in shape and activity; and on 20 clinical cases (10 lung and 10 esophageal cancer patients). The influence of the DPM parameters on contour generation was studied in two steps. In the first one, only the IEC spheres having diameters of 22 and 37 mm and a sphere of the digital phantom (41.6 mm diameter) were studied by varying the main parameters until the diameter of the spheres was obtained within 0.2% of the true value. In the second step, the results obtained for this training set were applied to the entire data set to determine DPM based volumes of all available lesions. These volumes were compared to those obtained by applying already known algorithms (Gaussian mixture model and gradient-based) and to true values, when available. Results: Only one parameter was found able to significantly influence segmentation accuracy (ANOVA test). This parameter was linearly connected to the uptake variance of the tested region of interest (ROI). In the first step of the study, a calibration curve was determined to automatically generate the optimal parameter from the variance of the ROI. This “calibration curve” was then applied to contour the whole data set. The accuracy (mean discrepancy between DPM model-based contours and reference contours) of volume estimation was below (1 ± 7)% on the whole data set (1 SD). The overlap between true and automatically segmented contours, measured by the Dice similarity coefficient, was 0.93 with a SD of 0.03. Conclusions: The proposed DPM model was able to accurately reproduce known volumes of FDG concentration, with high overlap between segmented and true volumes. For all the analyzed inserts of the IEC phantom, the algorithm proved to be robust to variations in radius and in TBR. The main advantage of this algorithm was that no setting of DPM parameters was required in advance, since the proper setting of the only parameter that could significantly influence the segmentation results was automatically related to the uptake variance of the chosen ROI. Furthermore, the algorithm did not need any preliminary choice of the optimum number of classes to describe the ROIs within PET images and no assumption about the shape of the lesion and the uptake heterogeneity of the tracer was required.« less
Fizeau interferometric cophasing of segmented mirrors: experimental validation.
Cheetham, Anthony; Cvetojevic, Nick; Norris, Barnaby; Sivaramakrishnan, Anand; Tuthill, Peter
2014-06-02
We present an optical testbed demonstration of the Fizeau Interferometric Cophasing of Segmented Mirrors (FICSM) algorithm. FICSM allows a segmented mirror to be phased with a science imaging detector and three filters (selected among the normal science complement). It requires no specialised, dedicated wavefront sensing hardware. Applying random piston and tip/tilt aberrations of more than 5 wavelengths to a small segmented mirror array produced an initial unphased point spread function with an estimated Strehl ratio of 9% that served as the starting point for our phasing algorithm. After using the FICSM algorithm to cophase the pupil, we estimated a Strehl ratio of 94% based on a comparison between our data and simulated encircled energy metrics. Our final image quality is limited by the accuracy of our segment actuation, which yields a root mean square (RMS) wavefront error of 25 nm. This is the first hardware demonstration of coarse and fine phasing an 18-segment pupil with the James Webb Space Telescope (JWST) geometry using a single algorithm. FICSM can be implemented on JWST using any of its scientic imaging cameras making it useful as a fall-back in the event that accepted phasing strategies encounter problems. We present an operational sequence that would co-phase such an 18-segment primary in 3 sequential iterations of the FICSM algorithm. Similar sequences can be readily devised for any segmented mirror.
Frost, Robert; Porter, David A; Miller, Karla L; Jezzard, Peter
2012-08-01
Single-shot echo-planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion-induced phase corruption in multishot data. Readout-segmented EPI has addressed the multishot problem by introducing a two-dimensional nonlinear navigator correction with online reacquisition of uncorrectable data to enable acquisition of high-resolution diffusion data with reduced susceptibility artifact and T*(2) blurring. The primary shortcoming of readout-segmented EPI in its current form is its long acquisition time (longer than similar resolution single-shot echo-planar imaging protocols by approximately the number of readout segments), which limits the number of diffusion directions. By omitting readout segments at one side of k-space and using partial Fourier reconstruction, readout-segmented EPI imaging times could be reduced. In this study, the effects of homodyne and projection onto convex sets reconstructions on estimates of the fractional anisotropy, mean diffusivity, and diffusion orientation in fiber tracts and raw T(2)- and trace-weighted signal are compared, along with signal-to-noise ratio results. It is found that projections onto convex sets reconstruction with 3/5 segments in a 2 mm isotropic diffusion tensor image acquisition and 9/13 segments in a 0.9 × 0.9 × 4.0 mm(3) diffusion-weighted image acquisition provide good fidelity relative to the full k-space parameters. This allows application of readout-segmented EPI to tractography studies, and clinical stroke and oncology protocols. Copyright © 2011 Wiley-Liss, Inc.
Smeets, Bart; Kuppe, Christoph; Sicking, Eva-Maria; Fuss, Astrid; Jirak, Peggy; van Kuppevelt, Toin H.; Endlich, Karlhans; Wetzels, Jack F.M.; Gröne, Hermann-Josef; Floege, Jürgen
2011-01-01
The pathogenesis of the development of sclerotic lesions in focal segmental glomerulosclerosis (FSGS) remains unknown. Here, we selectively tagged podocytes or parietal epithelial cells (PECs) to determine whether PECs contribute to sclerosis. In three distinct models of FSGS (5/6-nephrectomy + DOCA-salt; the murine transgenic chronic Thy1.1 model; or the MWF rat) and in human biopsies, the primary injury to induce FSGS associated with focal activation of PECs and the formation of cellular adhesions to the capillary tuft. From this entry site, activated PECs invaded the affected segment of the glomerular tuft and deposited extracellular matrix. Within the affected segment, podocytes were lost and mesangial sclerosis developed within the endocapillary compartment. In conclusion, these results demonstrate that PECs contribute to the development and progression of the sclerotic lesions that define FSGS, but this pathogenesis may be relevant to all etiologies of glomerulosclerosis. PMID:21719782
NASA Astrophysics Data System (ADS)
Lorditch, E.
2006-12-01
As a primary source of news, more people rely on local TV news than any other medium for their news and information. As a result, The American Geophysical Union has partnered with the American Institute of Physics in their production of Discoveries and Breakthroughs Inside Science (DBIS). DBIS is syndicated science news service that distributes 12, 90-second science news segments to over 80 local TV stations throughout the USA each month. Approximately 4 of these segments each month focus on research topics of interest to AGU members. Meet DBIS's senior science editor and learn about DBIS. Find out how you can improve your communication skills by participating in a DBIS segment or helping with DBIS production. Learn how the segment topics are chosen. Hear why the AGU got involved and how they work with the program.
Precision segmented reflectors for space applications
NASA Technical Reports Server (NTRS)
Lehman, David H.; Pawlik, Eugene V.; Meinel, Aden B.; Fichter, W. B.
1990-01-01
A project to develop precision segmented reflectors (PSRs) which operate at submillimeter wavelengths is described. The development of a light efficient means for the construction of large-aperture segmented reflecting space-based telescopes is the primary aim of the project. The 20-m Large Deployable Reflector (LDR) telescope is being developed for a survey mission, and it will make use of the reflector panels and materials, structures, and figure control being elaborated for the PSR. The surface accuracy of a 0.9-m PSR panel is shown to be 1.74-micron RMS, the goal of 100-micron RMS positioning accuracy has been achieved for a 4-m erectable structure. A voice-coil actuator for the figure control system architecture demonstrated 1-micron panel control accuracy in a 3-axis evaluation. The PSR technology is demonstrated to be of value for several NASA projects involving optical communications and interferometers as well as missions which make use of large-diameter segmented reflectors.
Precision segmented reflectors for space applications
NASA Astrophysics Data System (ADS)
Lehman, David H.; Pawlik, Eugene V.; Meinel, Aden B.; Fichter, W. B.
1990-08-01
A project to develop precision segmented reflectors (PSRs) which operate at submillimeter wavelengths is described. The development of a light efficient means for the construction of large-aperture segmented reflecting space-based telescopes is the primary aim of the project. The 20-m Large Deployable Reflector (LDR) telescope is being developed for a survey mission, and it will make use of the reflector panels and materials, structures, and figure control being elaborated for the PSR. The surface accuracy of a 0.9-m PSR panel is shown to be 1.74-micron RMS, the goal of 100-micron RMS positioning accuracy has been achieved for a 4-m erectable structure. A voice-coil actuator for the figure control system architecture demonstrated 1-micron panel control accuracy in a 3-axis evaluation. The PSR technology is demonstrated to be of value for several NASA projects involving optical communications and interferometers as well as missions which make use of large-diameter segmented reflectors.
Evolutionary Origin of Body Axis Segmentation in Annelids and Arthropods
NASA Technical Reports Server (NTRS)
Shankland, S. Martin
2003-01-01
During the period of this report, we have made a number of important discoveries. To date this work has led to 4 peer-reviewed publications in primary research journals plus 1 minireview and 1 chapter in the proceedings of a meeting. Publications resulting from this grant support are enumerated at the end of the report. Two additional, on-going studies also described. 1. Using laser cell ablation, we have obtained evidence that an annelid - the leech Helobdella robusta - patterns the anteroposterior (AP) polarity of its nascent segment primordia independent of cell interactions oriented along the AP axis. 2. We cloned a Helobdella homologue (hro-hh) of the Drosophila segment polarity gene hedgehog, and used in situ hybridization and northern blots to characterize its expression in the embryo. 3. We have used laser cell ablations to examine the possible role of cell interactions during the developmental patterning of the 4 rostralmost "head" segments of the leech Helobdella robusta.
Glycolytic reliance promotes anabolism in photoreceptors
Chinchore, Yashodhan; Begaj, Tedi; Wu, David; Drokhlyansky, Eugene; Cepko, Constance L
2017-01-01
Vertebrate photoreceptors are among the most metabolically active cells, exhibiting a high rate of ATP consumption. This is coupled with a high anabolic demand, necessitated by the diurnal turnover of a specialized membrane-rich organelle, the outer segment, which is the primary site of phototransduction. How photoreceptors balance their catabolic and anabolic demands is poorly understood. Here, we show that rod photoreceptors in mice rely on glycolysis for their outer segment biogenesis. Genetic perturbations targeting allostery or key regulatory nodes in the glycolytic pathway impacted the size of the outer segments. Fibroblast growth factor signaling was found to regulate glycolysis, with antagonism of this pathway resulting in anabolic deficits. These data demonstrate the cell autonomous role of the glycolytic pathway in outer segment maintenance and provide evidence that aerobic glycolysis is part of a metabolic program that supports the biosynthetic needs of a normal neuronal cell type. DOI: http://dx.doi.org/10.7554/eLife.25946.001 PMID:28598329
Hybrid Architecture Active Wavefront Sensing and Control
NASA Technical Reports Server (NTRS)
Feinberg, Lee; Dean, Bruce; Hyde, Tupper
2010-01-01
A method was developed for performing relatively high-speed wavefront sensing and control to overcome thermal instabilities in a segmented primary mirror telescope [e.g., James Webb Space Telescope (JWST) at L2], by using the onboard fine guidance sensor (FGS) to minimize expense and complexity. This FGS performs centroiding on a bright star to feed the information to the pointing and control system. The proposed concept is to beam split the image of the guide star (or use a single defocused guide star image) to perform wavefront sensing using phase retrieval techniques. Using the fine guidance sensor star image for guiding and fine phasing eliminates the need for other, more complex ways of achieving very accurate sensing and control that is needed for UV-optical applications. The phase retrieval occurs nearly constantly, so passive thermal stability over fourteen days is not required. Using the FGS as the sensor, one can feed segment update information to actuators on the primary mirror that can update the primary mirror segment fine phasing with this frequency. Because the thermal time constants of the primary mirror are very slow compared to this duration, the mirror will appear extremely stable during observations (to the level of accuracy of the sensing and control). The sensing can use the same phase retrieval techniques as the JWST by employing an additional beam splitter, and having each channel go through a weak lens (one positive and one negative). The channels can use common or separate detectors. Phase retrieval can be performed onboard. The actuation scheme would include a coarse stage able to achieve initial alignment of several millimeters of range (similar to JWST and can use a JWST heritage sensing approach in the science camera) and a fine stage capable of continual updates.
Peels, Hans O; de Swart, Hans; Ploeg, Tjeerd V D; Hautvast, Raymond W; Cornel, Jan H; Arnold, Alf E; Wharton, Thomas P; Umans, Victor A
2007-11-01
We investigated whether primary percutaneous coronary intervention (PCI) for patients admitted with an acute ST-segment elevation myocardial infarction could be performed more rapidly and with comparable outcomes in a community hospital versus a tertiary center with cardiac surgery. We started the first PCI with an off-site surgery program in The Netherlands in 2002 and report the results of 439 consecutive patients. In the safety phase, 199 patients presenting with ST-segment elevation myocardial infarction were randomly assigned to treatment at our off-site center versus a more distant cardiac surgery center. In the confirmation phase, 240 consecutive patients were treated in the off-site hospital. Safety and efficacy end points were the rate of an angiographically successful PCI procedure (diameter stenosis <50% and Thrombolysis In Myocardial Infarction grade 3 flow) in the absence of major adverse cardiac and cerebrovascular events at 30 days. The randomization phase showed a 37-minute decrease in door-to-balloon time (p <0.001) with comparable procedural and clinical successes (91% Thrombolysis In Myocardial Infarction grade 3 flow in the 2 groups). In the confirmation phase, the 30-day rate without major adverse cardiac and cerebrovascular events was 95%. None of the 439 patients in the study required emergency surgery for failed primary PCI. In conclusion, time to treatment with primary PCI can be significantly shortened when treating patients in a community hospital setting with off-site cardiac surgery backup compared with transport for PCI to a referral center with on-site surgery. PCI at hospitals with off-site cardiac surgery backup can be considered a needed strategy to improve access to primary PCI for a larger segment of the population and can be delivered with a very favorable safety profile.
A., Javadpour; A., Mohammadi
2016-01-01
Background Regarding the importance of right diagnosis in medical applications, various methods have been exploited for processing medical images solar. The method of segmentation is used to analyze anal to miscall structures in medical imaging. Objective This study describes a new method for brain Magnetic Resonance Image (MRI) segmentation via a novel algorithm based on genetic and regional growth. Methods Among medical imaging methods, brains MRI segmentation is important due to high contrast of non-intrusive soft tissue and high spatial resolution. Size variations of brain tissues are often accompanied by various diseases such as Alzheimer’s disease. As our knowledge about the relation between various brain diseases and deviation of brain anatomy increases, MRI segmentation is exploited as the first step in early diagnosis. In this paper, regional growth method and auto-mate selection of initial points by genetic algorithm is used to introduce a new method for MRI segmentation. Primary pixels and similarity criterion are automatically by genetic algorithms to maximize the accuracy and validity in image segmentation. Results By using genetic algorithms and defining the fixed function of image segmentation, the initial points for the algorithm were found. The proposed algorithms are applied to the images and results are manually selected by regional growth in which the initial points were compared. The results showed that the proposed algorithm could reduce segmentation error effectively. Conclusion The study concluded that the proposed algorithm could reduce segmentation error effectively and help us to diagnose brain diseases. PMID:27672629
Design, Fabrication, and Validation of an Ultra-Lightweight Membrane Mirror (Conference Proceedings)
2005-08-01
Membrane Mirror Active boundary control is very promising and studies predict good control over astigmatism and coma aberrations. However, the primary...design analysis. The mount has a split lenticular setup, allowing one canopy and many membrane mirrors that can be interchanged. The mount has a...spherical aberration, which is as expected. Results from finite element modeling showed that astigmatism can be corrected with the normal actuators
NASA Astrophysics Data System (ADS)
Briguglio, R.; Xompero, M.; Riccardi, A.; Lisi, F.; Duò, F.; Vettore, C.; Gallieni, D.; Tintori, M.; Lazzarini, P.; Patauner, C.; Biasi, R.; D'Amato, F.; Pucci, M.; Pereira do Carmo, João.
2017-11-01
The concept of a low areal density primary mirror, actively controlled by actuators, has been investigated through a demonstration prototype. A spherical mirror (400 mm diameter, 2.7 Kg mass) has been manufactured and tested in laboratory and on the optical bench, to verify performance, controllability and optical quality. In the present paper we will describe the prototype and the test results.
Liu, Yang; Zhang, Jieyu; Li, Ying; Hu, Yemin; Li, Wenxian; Zhu, Mingyuan; Hu, Pengfei; Chou, Shulei; Wang, Guoxiu
2017-01-01
To overcome the low lithium ion diffusion and slow electron transfer, a hollow micro sphere LiFePO4/C cathode material with a porous interior structure was synthesized via a solvothermal method by using ethylene glycol (EG) as the solvent medium and cetyltrimethylammonium bromide (CTAB) as the surfactant. In this strategy, the EG solvent inhibits the growth of the crystals and the CTAB surfactant boots the self-assembly of the primary nanoparticles to form hollow spheres. The resultant carbon-coat LiFePO4/C hollow micro-spheres have a ~300 nm thick shell/wall consisting of aggregated nanoparticles and a porous interior. When used as materials for lithium-ion batteries, the hollow micro spherical LiFePO4/C composite exhibits superior discharge capacity (163 mAh g−1 at 0.1 C), good high-rate discharge capacity (118 mAh g−1 at 10 C), and fine cycling stability (99.2% after 200 cycles at 0.1 C). The good electrochemical performances are attributed to a high rate of ionic/electronic conduction and the high structural stability arising from the nanosized primary particles and the micro-sized hollow spherical structure. PMID:29099814
Survey statistics of automated segmentations applied to optical imaging of mammalian cells.
Bajcsy, Peter; Cardone, Antonio; Chalfoun, Joe; Halter, Michael; Juba, Derek; Kociolek, Marcin; Majurski, Michael; Peskin, Adele; Simon, Carl; Simon, Mylene; Vandecreme, Antoine; Brady, Mary
2015-10-15
The goal of this survey paper is to overview cellular measurements using optical microscopy imaging followed by automated image segmentation. The cellular measurements of primary interest are taken from mammalian cells and their components. They are denoted as two- or three-dimensional (2D or 3D) image objects of biological interest. In our applications, such cellular measurements are important for understanding cell phenomena, such as cell counts, cell-scaffold interactions, cell colony growth rates, or cell pluripotency stability, as well as for establishing quality metrics for stem cell therapies. In this context, this survey paper is focused on automated segmentation as a software-based measurement leading to quantitative cellular measurements. We define the scope of this survey and a classification schema first. Next, all found and manually filteredpublications are classified according to the main categories: (1) objects of interests (or objects to be segmented), (2) imaging modalities, (3) digital data axes, (4) segmentation algorithms, (5) segmentation evaluations, (6) computational hardware platforms used for segmentation acceleration, and (7) object (cellular) measurements. Finally, all classified papers are converted programmatically into a set of hyperlinked web pages with occurrence and co-occurrence statistics of assigned categories. The survey paper presents to a reader: (a) the state-of-the-art overview of published papers about automated segmentation applied to optical microscopy imaging of mammalian cells, (b) a classification of segmentation aspects in the context of cell optical imaging, (c) histogram and co-occurrence summary statistics about cellular measurements, segmentations, segmented objects, segmentation evaluations, and the use of computational platforms for accelerating segmentation execution, and (d) open research problems to pursue. The novel contributions of this survey paper are: (1) a new type of classification of cellular measurements and automated segmentation, (2) statistics about the published literature, and (3) a web hyperlinked interface to classification statistics of the surveyed papers at https://isg.nist.gov/deepzoomweb/resources/survey/index.html.
SU-F-J-95: Impact of Shape Complexity On the Accuracy of Gradient-Based PET Volume Delineation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dance, M; Wu, G; Gao, Y
2016-06-15
Purpose: Explore correlation of tumor complexity shape with PET target volume accuracy when delineated with gradient-based segmentation tool. Methods: A total of 24 clinically realistic digital PET Monte Carlo (MC) phantoms of NSCLC were used in the study. The phantom simulated 29 thoracic lesions (lung primary and mediastinal lymph nodes) of varying size, shape, location, and {sup 18}F-FDG activity. A program was developed to calculate a curvature vector along the outline and the standard deviation of this vector was used as a metric to quantify a shape’s “complexity score”. This complexity score was calculated for standard geometric shapes and MC-generatedmore » target volumes in PET phantom images. All lesions were contoured using a commercially available gradient-based segmentation tool and the differences in volume from the MC-generated volumes were calculated as the measure of the accuracy of segmentation. Results: The average absolute percent difference in volumes between the MC-volumes and gradient-based volumes was 11% (0.4%–48.4%). The complexity score showed strong correlation with standard geometric shapes. However, no relationship was found between the complexity score and the accuracy of segmentation by gradient-based tool on MC simulated tumors (R{sup 2} = 0.156). When the lesions were grouped into primary lung lesions and mediastinal/mediastinal adjacent lesions, the average absolute percent difference in volumes were 6% and 29%, respectively. The former group is more isolated and the latter is more surround by tissues with relatively high SUV background. Conclusion: The complexity shape of NSCLC lesions has little effect on the accuracy of the gradient-based segmentation method and thus is not a good predictor of uncertainty in target volume delineation. Location of lesion within a relatively high SUV background may play a more significant role in the accuracy of gradient-based segmentation.« less
NASA Astrophysics Data System (ADS)
Zhao, Weiqiang; Liu, Hui; Liu, Jian
2016-11-01
At present day, in the field of lighting the incandescent lamps are phasing out. The solid state lighting products, i.e. LED, and the related market are developing very fast in China for its promising application, due to the energy-saving and the colorful features. For the quality control and the commercial trade purpose, it is highly necessary to measure the optical parameters of LED light sources with a fast, easy and affordable facility. Therefore, more test labs use the spherical spectrometer to measure LED. The quasi- monochrome of LED and the V(lambda) of silicon photodetector mismatch problem is reduced or avoided, because the total spectral radiant flux (TSRF) is measured, and all the optical parameters are calculate from the TSRF. In such a way, the spherical spectrometer calibration requires TSRF standard lamps instead of the traditional total flux standard lamps. National Institute of Metrology China (NIM) has studied and developed the facilities for TSRF measurement and provides related calibration services. This paper shows the TSRF standard lamp calibration procedure using a spherical spectrometer in every-day calibration and its traceable link to the primary SI unit at NIM. The sphere is of 1.5 m diameter, and installed with a spectrometer and a silicon photodetector. It also shows the detail of data process, such as the spectral absorption correction method and the calculation of the result derived from the spectral readings. The TSRF calibration covers the spectra range of 350 nm to 1050 nm, with a measurement uncertainty of 3.6% 1.8% (k=2).
Europa's Interaction with Jupiter's Magnetosphere: Galileo Plasma Observations Revisited.
NASA Astrophysics Data System (ADS)
Heuer, S. V.; Rymer, A. M.; Westlake, J. H.; Paterson, W. R.; Collinson, G.
2017-12-01
The Galileo spacecraft was active at Jupiter from December 1995 to September 2003, carrying the Galileo Plasma Science Instrument (PLS), an electrostatic analyzer with three spherical-segment plates which directed energy selected particles into one of seven electron sensors or seven ion channels with field-of-views which combined to cover 80% of the 4pi-sr unit sphere (Frank et al., 1992). While Galileo accomplished most of its primary scientific objectives, the mission did not reach its full potential due to a failed high-gain antenna deployment which severely limited the available bandwidth for data transmission. Consequently, the PLS was limited by bandwidth availability, and only collected data with high temporal and energy resolution for short periods of time (e.g. review by Bagenal et al., 2016). The electron sensors were also negatively affected by the gaseous environment around Jupiter, which is suspected to have deposited a layer of contaminants on the detectors, raising the threshold energy required to pass through the aperture and effectively preventing the measurement of electrons below 1keV (Frank et al., 2002). As a result, data from the PLS is challenging to process and interpret. Ion plasma moments have been computed (and published on the PDS) in the magnetosphere, but moon flybys were excluded (Bagenal et al., 2016). In anticipation of future in-situ exploration of the Europa plasma environment, we present analysis of full-resolution plasma data acquired by the PLS during the nine Europa flybys and compare our results with existing data in order to further inform designs currently being worked for the Europa Clipper and JUICE missions.
NASA Technical Reports Server (NTRS)
Klenzing, Jeffrey H.; Rowland, Douglas E.
2012-01-01
A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasmadensity is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future xed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.
Critical illumination condenser for x-ray lithography
Cohen, S.J.; Seppala, L.G.
1998-04-07
A critical illumination condenser system is disclosed, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 {micro}m source and requires a magnification of 26. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth. 6 figs.
A Charge-Exchange Neutral Particle Analyzer for an Inertial Electrostatic Confinement Fusion Device
NASA Astrophysics Data System (ADS)
Becerra, Gabriel; Kulcinski, Gerald; Santarius, John; Emmert, Gilbert
2013-10-01
An electrostatic energy analyzer for outgoing charge-exchange neutral particles has been designed and constructed for application on HELIOS, an inertial electrostatic confinement (IEC) fusion device designed for advanced fuel studies. Ions are extracted from an external helicon plasma source and subsequently accelerated radially into an electrostatic potential well set up by a semi-transparent cathode grid inside the HELIOS spherical chamber. Analysis of fast neutrals produced by charge exchange between energetic ions and background gas yields information on primary ion energy spectra, as well as a quantitative measure of charge exchange as an energy loss mechanism in IEC devices. Preliminary data with helium is used to benchmark the two-charge-state helium formalism of VICTER, a numerical code on spherically convergent ion flow, as it relates to IEC operation with helium-3 fuel. Research supported by the Greatbatch Foundation.
Contributions of microtubule rotation and dynamic instability to kinetochore capture
NASA Astrophysics Data System (ADS)
Sweezy-Schindler, Oliver; Edelmaier, Christopher; Blackwell, Robert; Glaser, Matt; Betterton, Meredith
2014-03-01
The capture of lost kinetochores (KCs) by microtubules (MTs) is a crucial part of prometaphase during mitosis. Microtubule dynamic instability has been considered the primary mechanism of KC capture, but recent work discovered that lateral KC attachment to pivoting MTs enabled rapid capture even with significantly reduced MT dynamics. We aim to understand the relative contributions of MT rotational diffusion and dynamic instability to KC capture, as well as KC capture through end-on and/or lateral attachment. Our model consists of rigid MTs and a spherical KC, which are allowed to diffuse inside a spherical nuclear envelope consistent with the geometry of fission yeast. For simplicity, we include a single spindle pole body, which is anchored to the nuclear membrane, and its associated polar MTs. Brownian dynamics treats the diffusion of the MTs and KC and kinetic Monte Carlo models stochastic processes such as dynamic instability. NSF 1546021.
NASA Technical Reports Server (NTRS)
Miyoshi, K.; Buckley, D. H.
1981-01-01
Sliding friction experiments were performed in vacuum at room temperature on a plane-type SiC surface in contact with iron-based binary alloys. Multiangular and spherical wear particles were found to form as a result of multipass sliding. The multiangular particles were produced by primary and secondary cracking of the 0001, 10(-)10, and 11(-)20 plane-type cleavage planes under the Hertzian stress field or local inelastic deformation zone. When alloy surfaces are in contact with silicon carbide under a load of 0.2 N, the alloy around the contact area is subjected to stresses that are close to the elastic limit in the elastic deformation region and/or exceed it. It was also found that spherical wear particles may be produced by two mechanisms: a penny-shaped fracture along the circular stress trajectories under the local inelastic deformation zone, and the attrition and fatigue of wear particles.
Critical illumination condenser for x-ray lithography
Cohen, Simon J.; Seppala, Lynn G.
1998-01-01
A critical illumination condenser system, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 .mu.m source and requires a magnification of 26.times.. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth.
Leaf position optimization for step-and-shoot IMRT.
De Gersem, W; Claus, F; De Wagter, C; Van Duyse, B; De Neve, W
2001-12-01
To describe the theoretical basis, the algorithm, and implementation of a tool that optimizes segment shapes and weights for step-and-shoot intensity-modulated radiation therapy delivered by multileaf collimators. The tool, called SOWAT (Segment Outline and Weight Adapting Tool) is applied to a set of segments, segment weights, and corresponding dose distribution, computed by an external dose computation engine. SOWAT evaluates the effects of changing the position of each collimating leaf of each segment on an objective function, as follows. Changing a leaf position causes a change in the segment-specific dose matrix, which is calculated by a fast dose computation algorithm. A weighted sum of all segment-specific dose matrices provides the dose distribution and allows computation of the value of the objective function. Only leaf position changes that comply with the multileaf collimator constraints are evaluated. Leaf position changes that tend to decrease the value of the objective function are retained. After several possible positions have been evaluated for all collimating leaves of all segments, an external dose engine recomputes the dose distribution, based on the adapted leaf positions and weights. The plan is evaluated. If the plan is accepted, a segment sequencer is used to make the prescription files for the treatment machine. Otherwise, the user can restart SOWAT using the new set of segments, segment weights, and corresponding dose distribution. The implementation was illustrated using two example cases. The first example is a T1N0M0 supraglottic cancer case that was distributed as a multicenter planning exercise by investigators from Rotterdam, The Netherlands. The exercise involved a two-phase plan. Phase 1 involved the delivery of 46 Gy to a concave-shaped planning target volume (PTV) consisting of the primary tumor volume and the elective lymph nodal regions II-IV on both sides of the neck. Phase 2 involved a boost of 24 Gy to the primary tumor region only. SOWAT was applied to the Phase 1 plan. Parotid sparing was a planning goal. The second implementation example is an ethmoid sinus cancer case, planned with the intent of bilateral visus sparing. The median PTV prescription dose was 70 Gy with a maximum dose constraint to the optic pathway structures of 60 Gy. The initial set of segments, segment weights, and corresponding dose distribution were obtained, respectively, by an anatomy-based segmentation tool, a segment weight optimization tool, and a differential scatter-air ratio dose computation algorithm as external dose engine. For the supraglottic case, this resulted in a plan that proved to be comparable to the plans obtained at the other institutes by forward or inverse planning techniques. After using SOWAT, the minimum PTV dose and PTV dose homogeneity increased; the maximum dose to the spinal cord decreased from 38 Gy to 32 Gy. The left parotid mean dose decreased from 22 Gy to 19 Gy and the right parotid mean dose from 20 to 18 Gy. For the ethmoid sinus case, the target homogeneity increased by leaf position optimization, together with a better sparing of the optical tracts. By using SOWAT, the plans improved with respect to all plan evaluation end points. Compliance with the multileaf collimator constraints is guaranteed. The treatment delivery time remains almost unchanged, because no additional segments are created.
Raghupathy, Rakesh K; Zhang, Xun; Alhasani, Reem H; Zhou, Xinzhi; Mullin, Margaret; Reilly, James; Li, Wenchang; Liu, Mugen; Shu, Xinhua
2016-08-01
Photoreceptors are highly specialized sensory neurons that possess a modified primary cilium called the outer segment. Photoreceptor outer segment formation and maintenance require highly active protein transport via a process known as intraflagellar transport. Anterograde transport in outer segments is powered by the heterotrimeric kinesin II and coordinated by intraflagellar transport proteins. Here, we describe a new zebrafish model carrying a nonsense mutation in the kinesin II family member 3A (kif3a) gene. Kif3a mutant zebrafish exhibited curved body axes and kidney cysts. Outer segments were not formed in most parts of the mutant retina, and rhodopsin was mislocalized, suggesting KIF3A has a role in rhodopsin trafficking. Both rod and cone photoreceptors degenerated rapidly between 4 and 9 days post fertilization, and electroretinography response was not detected in 7 days post fertilization mutant larvae. Loss of KIF3A in zebrafish also resulted in an intracellular transport defect affecting anterograde but not retrograde transport of organelles. Our results indicate KIF3A plays a conserved role in photoreceptor outer segment formation and intracellular transport. Copyright © 2016 John Wiley & Sons, Ltd.
Vargas-Barron, Jesús; Antunez-Montes, Omar-Yassef; Roldán, Francisco-Javier; Aranda-Frausto, Alberto; González-Pacheco, Hector; Romero-Cardenas, Ángel; Zabalgoitia, Miguel
2015-01-01
Torrent-Guasp explains the structure of the ventricular myocardium by means of a helical muscular band. Our primary purpose was to demonstrate the utility of echocardiography in human and porcine hearts in identifying the segments of the myocardial band. The second purpose was to evaluate the relation of the topographic distribution of the myocardial band with some post-myocardial infarction ruptures. Five porcine and one human heart without cardiopathy were dissected and the ventricular myocardial segments were color-coded for illustration and reconstruction purposes. These segments were then correlated to the conventional echocardiographic images. Afterwards in three cases with post-myocardial infarction rupture, a correlation of the topographic location of the rupture with the distribution of the ventricular band was made. The human ventricular band does not show any differences from the porcine band, which confirms the similarities of the four segments; these segments could be identified by echocardiography. In three cases with myocardial rupture, a correlation of the intra-myocardial dissection with the distribution of the ventricular band was observed. Echocardiography is helpful in identifying the myocardial band segments as well as the correlation with the topographic distribution of some myocardial post-infarction ruptures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Zhang, L; Fave, X
Purpose: Determine the impact of morphologic characteristics (e.g. necrosis, vascular enhancement, and cavitation) on radiomic features from contrast enhanced CT (CE-CT) in primary lung tumors. Methods: We developed an auto-segmentation algorithm to separate lung tumors on contrast-enhanced CT into cavitation (air), necrosis, tissue, and enhancing vessels using a combination of thresholding and region-growing. An auto-segmentation algorithm was also designed to identify necrosis on FDG-PET scans. Wilcoxon rank-sum tests were used to determine if significant differences existed in radiomics features (histogram-uniformity and Laplacian-of-Gaussian average) from 249 patients, found to prognostic in previous work, based on the presence/absence of morphologic features. Featuremore » values were also compared between the original tumor contours and contours excluding a specific morphologic feature. Comparison of necrosis segmentation on CE-CT versus FDG-PET was performed in 78 patients to assess for agreement using the concordance correlation coefficient (CCC). Results: Tumors with cavitation and enhancing vasculature had lower uniformity values (p = 0.001 and p = 0.03, respectively). Tumors with enhancing vasculature and necrosis had higher Laplacian-of-Gaussian average values (measure of “edges” within the tumor) (p < 0.001). Removing these tissue types from regions-of-interest did not drastically alter either radiomic feature value (all scenarios had R{sup 2} > 0.8). This suggests there may be interactions between morphologic characteristics and the radiomic feature value of tumor tissue. Comparison of necrosis volume and percent necrosis volume of tumor were found to have CCC values of 0.85 and 0.76, respectively between CE-CT and FDG-PET segmentation methods. Conclusions: Tumors with enhancing vasculature, necrosis, and cavitation have higher radiomic feature values that are associated with poor prognosis than tumors without these features. Removing these tissue types from quantitative assessment did not drastically impact radiomic feature values. High reproducibility of CE-CT segmented necrosis compared to FDG-PET segmented necrosis provides a reasonable validation of segmentation accuracy on CE-CT.« less
NASA Astrophysics Data System (ADS)
Baars, Holger; Seifert, Patric; Engelmann, Ronny; Wandinger, Ulla
2017-09-01
Absolute calibrated signals at 532 and 1064 nm and the depolarization ratio from a multiwavelength lidar are used to categorize primary aerosol but also clouds in high temporal and spatial resolution. Automatically derived particle backscatter coefficient profiles in low temporal resolution (30 min) are applied to calibrate the lidar signals. From these calibrated lidar signals, new atmospheric parameters in temporally high resolution (quasi-particle-backscatter coefficients) are derived. By using thresholds obtained from multiyear, multisite EARLINET (European Aerosol Research Lidar Network) measurements, four aerosol classes (small; large, spherical; large, non-spherical; mixed, partly non-spherical) and several cloud classes (liquid, ice) are defined. Thus, particles are classified by their physical features (shape and size) instead of by source. The methodology is applied to 2 months of continuous observations (24 h a day, 7 days a week) with the multiwavelength-Raman-polarization lidar PollyXT during the High-Definition Clouds and Precipitation for advancing Climate Prediction (HD(CP)2) Observational Prototype Experiment (HOPE) in spring 2013. Cloudnet equipment was operated continuously directly next to the lidar and is used for comparison. By discussing three 24 h case studies, it is shown that the aerosol discrimination is very feasible and informative and gives a good complement to the Cloudnet target categorization. Performing the categorization for the 2-month data set of the entire HOPE campaign, almost 1 million pixel (5 min × 30 m) could be analysed with the newly developed tool. We find that the majority of the aerosol trapped in the planetary boundary layer (PBL) was composed of small particles as expected for a heavily populated and industrialized area. Large, spherical aerosol was observed mostly at the top of the PBL and close to the identified cloud bases, indicating the importance of hygroscopic growth of the particles at high relative humidity. Interestingly, it is found that on several days non-spherical particles were dispersed from the ground into the atmosphere.
Architectural study of the design and operation of advanced force feedback manual controllers
NASA Technical Reports Server (NTRS)
Tesar, Delbert; Kim, Whee-Kuk
1990-01-01
A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.
Chimba, Deo; Kutela, Boniphace
2014-09-01
Extent of secondary crashes derived from primary incidents involving abandoned and disabled vehicles are presented in this paper. Using years 2004 to 2010 incident and crash data on selected Tennessee freeways, the study identified secondary crashes that resulted from disabled and abandoned vehicle primary incidents. The relationship between time and distance gaps before the secondary crash with respect to individual incident characteristics were evaluated through descriptive statistics and linear regression. The time and distance gap analysis indicated that a large portion of secondary crashes occurred within 20 min after the primary incidents and within a distance of 0.5 miles upstream. While 76% of incidents involved shoulder, most secondary crashes were related to the closing of right lanes. Overall, 58% of the secondary crashes occurred within 30 min after the occurrence of the primary incidents. Most of the vehicles in the incidents that involved towing and caused secondary crashes were towed or removed out of the travel way within 60 min from the time of occurrence. The study found that most (95%) secondary crashes were property damage only (PDO), while 49% were rear-end crashes. The negative binomial model was used to evaluate the impact of roadway geometry and traffic factors associated with frequency of these secondary crashes. It was found that the posted speed limit, congested segments, segments with high percentages of trucks, and peak hour volumes increased the likelihood of secondary crash occurrence. Roadway segments with wider medians, shoulders, and multilanes decrease the likelihood of secondary crashes caused by abandoned and disabled vehicles as the primary incidents. Practical applications The paper recommends that wider shoulders be provided on any section of freeway to accommodate abandoned or disabled vehicles to avoid blocking of travel lane(s). Copyright © 2014 National Safety Council and Elsevier Ltd. All rights reserved.
Hematopoiesis In The Equine Fetal Liver Suggests Immune Preparedness
Battista, JM; Tallmadge, RL; Stokol, T; Felippe, MJB
2014-01-01
We investigated how the equine fetus prepares its pre-immune humoral repertoire for an imminent exposure to pathogens in the neonatal period, particularly how the primary hematopoietic organs are equipped to support B cell hematopoiesis and immunoglobulin (Ig) diversity. We demonstrated that the liver and the bone marrow at approximately 100 days of gestation (DG) are active sites of hematopoiesis based on the expression of signature mRNA (c-KIT, CD34, IL7R, CXCL12, IRF8, PU.1, PAX5, NOTCH1, GATA1, CEBPA) and protein markers (CD34, CD19, IgM, CD3, CD4, CD5, CD8, CD11b, CD172A) of hematopoietic development and leukocyte differentiation molecules, respectively. To verify Ig diversity achieved during the production of B cells, V(D)J segments were sequenced in primary lymphoid organs of the equine fetus and adult horse, revealing that similar heavy chain VDJ segments and CDR3 lengths were most frequently used independent of life stage. In contrast, different lambda light chain segments were predominant in equine fetal compared to adult stage and, surprisingly, the fetus had less restricted use of variable gene segments to construct the lambda chain. Fetal Igs also contained elements of sequence diversity, albeit to a smaller degree than that of the adult horse. Our data suggest that the B cells produced in the liver and bone marrow of the equine fetus generate a wide repertoire of pre-immune Igs for protection, and the more diverse use of different lambda variable gene segments in fetal life may provide the neonate an opportunity to respond to a wider range of antigens at birth. PMID:25179685
Muñoz, Daniel; Roettig, Mayme L; Monk, Lisa; Al-Khalidi, Hussein; Jollis, James G; Granger, Christopher B
2012-08-01
For patients with ST-segment elevation myocardial infarction transferred for primary percutaneous coronary intervention, guidelines have called for device activation within 90 minutes of initial presentation. Fewer than 20% of transferred patients are treated in such a timely fashion. We examine the association between transfer drive times and door-to-device (D2D) times in a network of North Carolina hospitals. We compare the feasibility of timely percutaneous coronary intervention using ground versus air transfer. We perform a retrospective analysis of the relationship between transfer drive times and D2D times in a 119-hospital ST-segment-elevation myocardial infarction statewide network. Between July 2008 and December 2009, 1537 ST-segment-elevation myocardial infarction patients underwent interhospital transfer for reperfusion via primary percutaneous coronary intervention. For ground transfers, median D2D time was 93 minutes for drive times ≤30 minutes, 117 minutes for drive times of 31 to 45 minutes, and 121 minutes for drive times >45 minutes. For air transfers, median D2D time was 125 minutes for drive times of 31 to 45 minutes and 138 minutes for drive times >45 minutes. Helicopter transport was associated with longer door-in door-out times and, ultimately, was associated with median D2D times that exceeded guideline recommendations, no matter the transfer drive time category. In a well-developed ST-segment-elevation myocardial infarction system, D2D times within 90 to 120 minutes appear most feasible for hospitals within 30-minute transfer drive time. Helicopter transport did not offer D2D time advantages for transferred STEMI patients. This finding appears to be attributable to comparably longer door-in door-out times for air transfers.
Functional gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC).
Hinrichs, Heiko; Hinrichs, Jan B; Gutberlet, Marcel; Lenzen, Henrike; Raatschen, Hans-Juergen; Wacker, Frank; Ringe, Kristina I
2016-04-01
To assess the value of variable flip angle-based T1 liver mapping on gadoxetate disodium-enhanced MRI in patients with primary sclerosing cholangitis (PSC) for evaluation of global and segmental liver function, and determine a possible correlation with disease severity. Sixty-one patients (19 female, 42 male; mean age 41 years) with PSC were included in this prospective study. T1 mapping was performed using a 3D-spoiled GRE sequence (flip angles 5°, 15°, 20°, 30°) before, 16 (HP1) and 132 min (HP2) after contrast injection. T1 values were measured and compared (Wilcoxon-Test) by placing ROIs in each liver segment. The mean reduction of T1 relaxation time at HP1 and HP2 was calculated and correlated with liver function tests (LFTs), MELD, Mayo Risk and Amsterdam Scores (Spearman correlation). Significant changes of T1 relaxation times between non-enhanced and gadoxetate disodium-enhanced MRI at HP1 and HP2 could be observed in all liver segments (p < 0.0001). A significant correlation of T1 reduction could be observed with LFTs, MELD and Mayo Risk Score (p < 0.05). T1 mapping of the liver using a variable flip angle-based sequence is a feasible technique to evaluate liver function on a global level, and may be extrapolated on a segmental level in patients with PSC. • T1 mapping enables evaluation of global liver function in PSC. • T1 relaxation time reduction correlates with the MELD and MayoRisk Score. • Extrapolated, T1 mapping may allow for segmental evaluation of liver function.
Three-dimensional choroidal segmentation in spectral OCT volumes using optic disc prior information
NASA Astrophysics Data System (ADS)
Hu, Zhihong; Girkin, Christopher A.; Hariri, Amirhossein; Sadda, SriniVas R.
2016-03-01
Recently, much attention has been focused on determining the role of the peripapillary choroid - the layer between the outer retinal pigment epithelium (RPE)/Bruchs membrane (BM) and choroid-sclera (C-S) junction, whether primary or secondary in the pathogenesis of glaucoma. However, the automated choroidal segmentation in spectral-domain optical coherence tomography (SD-OCT) images of optic nerve head (ONH) has not been reported probably due to the fact that the presence of the BM opening (BMO, corresponding to the optic disc) can deflect the choroidal segmentation from its correct position. The purpose of this study is to develop a 3D graph-based approach to identify the 3D choroidal layer in ONH-centered SD-OCT images using the BMO prior information. More specifically, an initial 3D choroidal segmentation was first performed using the 3D graph search algorithm. Note that varying surface interaction constraints based on the choroidal morphological model were applied. To assist the choroidal segmentation, two other surfaces of internal limiting membrane and innerouter segment junction were also segmented. Based on the segmented layer between the RPE/BM and C-S junction, a 2D projection map was created. The BMO in the projection map was detected by a 2D graph search. The pre-defined BMO information was then incorporated into the surface interaction constraints of the 3D graph search to obtain more accurate choroidal segmentation. Twenty SD-OCT images from 20 healthy subjects were used. The mean differences of the choroidal borders between the algorithm and manual segmentation were at a sub-voxel level, indicating a high level segmentation accuracy.
Hayıroğlu, Mert İlker; Keskin, Muhammed; Uzun, Ahmet Okan; Türkkan, Ceyhan; Tekkeşin, Ahmet İlker; Kozan, Ömer
Electrical phenomenon and remote myocardial ischemia are the main factors of ST segment depression in inferior leads in acute anterior myocardial infarction (AAMI). We investigated the prognostic value of the sum of ST segment depression amplitudes in inferior leads in patients with first AAMI treated with primary percutaneous coronary intervention. (PPCI). In this prospective analysis, we evaluated the in-hospital prognostic impact of the sum of ST segment depression in inferior leads on 206 patients with first AAMI. Patients were stratified by tertiles of the sum of admission ST segment depression in inferior leads. Clinical outcomes were compared between those tertiles. Univariate analysis revealed higher rate of in-hospital death for patients with ST segment depression in inferior leads in tertile 3, as compared to patients in tertile 1 (OR 9.8, 95% CI 1.5-78.2, p<0.001). After adjustment for baseline variables, ST segment depression in inferior leads in tertile 3 was associated with 5.7-fold hazard of in-hospital death (OR: 5.7, 95% CI 1.2-35.1, p<0.001). Spearman rank correlation test revealed correlation between the sum of ST segment depression amplitude in inferior leads and the sum of ST segment elevation amplitude in V1-6, L1 and aVL. Multivessel disease and additional RCA stenosis were also detected more often in tertile 3. The sum of ST segment depression amplitude in inferior leads of admission ECG in patients with first AAMI treated with PPCI provide an independent prognostic marker of in-hospital outcomes. Our data suggest the sum of ST segment depression amplitude to be a simple, feasible and clinically applicable tool for rapid risk stratification in patients with first AAMI. Copyright © 2017 Elsevier Inc. All rights reserved.
Saltation of Non-Spherical Sand Particles
Wang, Zhengshi; Ren, Shan; Huang, Ning
2014-01-01
Saltation is an important geological process and the primary source of atmospheric mineral dust aerosols. Unfortunately, no studies to date have been able to precisely reproduce the saltation process because of the simplified theoretical models used. For example, sand particles in most of the existing wind sand movement models are considered to be spherical, the effects of the sand shape on the structure of the wind sand flow are rarely studied, and the effect of mid-air collision is usually neglected. In fact, sand grains are rarely round in natural environments. In this paper, we first analyzed the drag coefficients, drag forces, and starting friction wind speeds of sand grains with different shapes in the saltation process, then established a sand saltation model that considers the coupling effect between wind and the sand grains, the effect of the mid-air collision of sand grains, and the effect of the sand grain shape. Based on this model, the saltation process and sand transport rate of non-spherical sand particles were simulated. The results show that the sand shape has a significant impact on the saltation process; for the same wind speed, the sand transport rates varied for different shapes of sand grains by as much as several-fold. Therefore, sand shape is one of the important factors affecting wind-sand movement. PMID:25170614
Pyrolysis of Large Black Liquor Droplets
NASA Technical Reports Server (NTRS)
Bartkus, Tadas P.; Dietrich, Daniel L.; T'ien, James S.; Wessel, Richard A.
2007-01-01
This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY)) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.
Pyrolysis of Large Black Liquor Droplets
NASA Technical Reports Server (NTRS)
Bartkus, Tadas P.; T'ien, James S.; Dietrich, Daniel L.; Wessel, Richard A.
2007-01-01
This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY) ) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.
Validation of refraction and anterior segment parameters by a new multi-diagnostic platform (VX120).
Gordon-Shaag, Ariela; Piñero, David P; Kahloun, Cyril; Markov, David; Parnes, Tzadok; Gantz, Liat; Shneor, Einat
2018-03-08
The VX120 (Visionix Luneau, France) is a novel multi-diagnostic platform that combines Hartmann-Shack based autorefraction, Placido-disk based corneal-topography and anterior segment measurements made with a stationary-Scheimpflug camera. We investigate the agreement between different parameters measured by the VX120 with accepted or gold-standard techniques to test if they are interchangeable, as well as to evaluate the repeatability and reproducibility. The right-eyes of healthy subjects were included in the study. Autorefraction of the VX120 was compared to subjective refraction. Agreement of anterior segment parameters was compared to the Sirius (CSO, Italy) including autokeratometry, central corneal thickness (CCT), iridiocorneal angle (IA). Inter and intra-test repeatability of the above parameters was assessed. Results were analyzed using Bland and Altman analyses. A total of 164 eyes were evaluated. The mean difference between VX120 autorefraction and subjective refraction for sphere, spherical equivalent (SE), and cylinder was 0.01±0.43D, 0.14±0.47D, and -0.26±0.30D, respectively and high correlation was found to all parameter (r>0.75) except for J 45 (r=0.61). The mean difference between VX120 and the Sirius system for CCT, IA, and keratometry (k1 and k2) was -3.51±8.64μm, 7.6±4.2°, 0.003±0.06mm and 0.004±0.04mm, respectively and high correlation was found to all parameter (r>0.97) except for IA (r=0.67). Intrasession repeatability of VX120 refraction, CCT, IA and keratometry yielded low within-subject standard deviations. Inter-session repeatability showed no statistically significant difference for most of the parameters measured. The VX120 provides consistent refraction and most anterior segment measurements in normal healthy eyes, with high levels of intra and inter-session repeatability. Copyright © 2018. Published by Elsevier España, S.L.U.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soufi, M; Asl, A Kamali; Geramifar, P
2015-06-15
Purpose: The objective of this study was to find the best seed localization parameters in random walk algorithm application to lung tumor delineation in Positron Emission Tomography (PET) images. Methods: PET images suffer from statistical noise and therefore tumor delineation in these images is a challenging task. Random walk algorithm, a graph based image segmentation technique, has reliable image noise robustness. Also its fast computation and fast editing characteristics make it powerful for clinical purposes. We implemented the random walk algorithm using MATLAB codes. The validation and verification of the algorithm have been done by 4D-NCAT phantom with spherical lungmore » lesions in different diameters from 20 to 90 mm (with incremental steps of 10 mm) and different tumor to background ratios of 4:1 and 8:1. STIR (Software for Tomographic Image Reconstruction) has been applied to reconstruct the phantom PET images with different pixel sizes of 2×2×2 and 4×4×4 mm{sup 3}. For seed localization, we selected pixels with different maximum Standardized Uptake Value (SUVmax) percentages, at least (70%, 80%, 90% and 100%) SUVmax for foreground seeds and up to (20% to 55%, 5% increment) SUVmax for background seeds. Also, for investigation of algorithm performance on clinical data, 19 patients with lung tumor were studied. The resulted contours from algorithm have been compared with nuclear medicine expert manual contouring as ground truth. Results: Phantom and clinical lesion segmentation have shown that the best segmentation results obtained by selecting the pixels with at least 70% SUVmax as foreground seeds and pixels up to 30% SUVmax as background seeds respectively. The mean Dice Similarity Coefficient of 94% ± 5% (83% ± 6%) and mean Hausdorff Distance of 1 (2) pixels have been obtained for phantom (clinical) study. Conclusion: The accurate results of random walk algorithm in PET image segmentation assure its application for radiation treatment planning and diagnosis.« less
Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET.
Hatt, M; Lamare, F; Boussion, N; Turzo, A; Collet, C; Salzenstein, F; Roux, C; Jarritt, P; Carson, K; Cheze-Le Rest, C; Visvikis, D
2007-06-21
Accurate volume of interest (VOI) estimation in PET is crucial in different oncology applications such as response to therapy evaluation and radiotherapy treatment planning. The objective of our study was to evaluate the performance of the proposed algorithm for automatic lesion volume delineation; namely the fuzzy hidden Markov chains (FHMC), with that of current state of the art in clinical practice threshold based techniques. As the classical hidden Markov chain (HMC) algorithm, FHMC takes into account noise, voxel intensity and spatial correlation, in order to classify a voxel as background or functional VOI. However the novelty of the fuzzy model consists of the inclusion of an estimation of imprecision, which should subsequently lead to a better modelling of the 'fuzzy' nature of the object of interest boundaries in emission tomography data. The performance of the algorithms has been assessed on both simulated and acquired datasets of the IEC phantom, covering a large range of spherical lesion sizes (from 10 to 37 mm), contrast ratios (4:1 and 8:1) and image noise levels. Both lesion activity recovery and VOI determination tasks were assessed in reconstructed images using two different voxel sizes (8 mm3 and 64 mm3). In order to account for both the functional volume location and its size, the concept of % classification errors was introduced in the evaluation of volume segmentation using the simulated datasets. Results reveal that FHMC performs substantially better than the threshold based methodology for functional volume determination or activity concentration recovery considering a contrast ratio of 4:1 and lesion sizes of <28 mm. Furthermore differences between classification and volume estimation errors evaluated were smaller for the segmented volumes provided by the FHMC algorithm. Finally, the performance of the automatic algorithms was less susceptible to image noise levels in comparison to the threshold based techniques. The analysis of both simulated and acquired datasets led to similar results and conclusions as far as the performance of segmentation algorithms under evaluation is concerned.
Chandraratna, P Anthony N; Mohar, Dilbahar S; Sidarous, Peter F; Brar, Prabhjyot; Miller, Jeffrey; Shah, Nissar; Kadis, John; Ali, Ashgar; Mohar, Prabhsimran
2012-09-01
This investigation was designed to test the hypothesis that continuous cardiac imaging using an ultrasound transducer developed in our laboratory (ContiScan) is superior to electrocardiogram (ECG) monitoring in the diagnosis of coronary artery disease (CAD) in patients with acute non-ST segment elevation chest pain syndromes. Seventy patients with intermediate to high probability of CAD who presented with typical anginal chest pain and no evidence of ST segment elevation on the ECG were studied. The 2.5-MHz transducer is spherical in its distal part mounted in an external housing to permit steering in 360 degrees. The transducer was placed at the left sternal border to image the left ventricular short-axis view and recorded on video tape at baseline, during and after episodes of chest pain. Two ECG leads were continuously monitored. The presence of CAD was confirmed by coronary arteriography or nuclear or echocardiographic stress testing. Twenty-four patients had regional wall motion abnormalities (RWMA) on their initial echo which were unchanged during the period of monitoring. All had evidence of CAD. Twenty-eight patients had transient RWMA. All had evidence of CAD. Eighteen patients had normal wall motion throughout the monitoring period, 14 of these had no evidence of CAD, and four had evidence of CAD. These four patients did not have chest pain during monitoring. The sensitivity, specificity, and accuracy of echocardiographic monitoring for diagnosing non-ST elevation myocardial infarction was 88%, 100%, and 91% respectively. The sensitivity, specificity, and accuracy of the ECG for diagnosis of CAD were 31%, 100%, and 52%, respectively. Echocardiography was superior to ECG (P < 0.001). The data indicate that continuous cardiac imaging is superior to ECG monitoring for the diagnosis of CAD in patients presenting with acute non-ST segment elevation chest pain syndromes. This technique could be a useful adjunct to ECG monitoring for myocardial ischemia in the acute care setting. © 2012, Wiley Periodicals, Inc.
The 4-meter lunar engineering telescope
NASA Technical Reports Server (NTRS)
Peacock, Keith; Giannini, Judith A.; Kilgus, Charles C.; Bely, Pierre Y.; May, B. Scott; Cooper, Shannon A.; Schlimm, Gerard H.; Sounder, Charles; Ormond, Karen; Cheek, Eric
1991-01-01
The 16-meter diffraction limited lunar telescope incorporates a primary mirror with 312 one-meter segments; 3 nanometer active optics surface control with laser metrology and hexapod positioners; a space frame structure with one-millimeter stability; and a hexapod mount for pointing. The design data needed to limit risk in this development can be obtained by building a smaller engineering telescope on the moon with all of the features of the 16-meter design. This paper presents a 4.33-meter engineering telescope concept developed by the Summer 1990 Student Program of the NASA/JHU Space Grant Consortium Lunar Telescope Project. The primary mirror, made up of 18 one-meter hexagonal segments, is sized to provide interesting science as well as engineering data. The optics are configured as a Ritchey-Chretien with a coude relay to the focal plane beneath the surface. The optical path is continuously monitored with 3-nanometer precision interferometrically. An active optics processor and piezoelectric actuators operate to maintain the end-to-end optical configuration established by wave front sensing using a guide star. The mirror segments, consisting of a one-centimeter thick faceplate on 30-cm deep ribs, maintain the surface figure to a few nanometers under lunar gravity and thermal environment.
JWST center of curvature test method and results
NASA Astrophysics Data System (ADS)
Saif, Babak; Chaney, David; Greenfield, Perry; Van Gorkom, Kyle; Brooks, Keira; Hack, Warren; Bluth, Marcel; Bluth, Josh; Sanders, James; Smith, Koby; Carey, Larkin; Chaung, Sze; Keski-Kuha, Ritva; Feinberg, Lee; Tournois, Severine; Smith, W. Scott; Kradinov, Vladimir
2017-09-01
The James Webb Space Telescope (JWST) recently saw the completion of the assembly process for the Optical Telescope Element and Integrated Science Instrument Module (OTIS). This integration effort was performed at Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. In conjunction with this assembly process a series of vibration and acoustic tests were performed. To help assure the telescope's primary mirror was not adversely impacted by this environmental testing an optical center of curvature (CoC) test was performed to measure changes in the mirror's optical performance. The primary is a 6.5 meter diameter mirror consisting of 18 individual hexagonal segments. Each segment is an off-axis asphere. There are a total of three prescriptions repeated six times each. As part of the CoC test each segment was individually measured using a high-speed interferometer (HSI) designed and built specifically for this test. This interferometer is capable of characterizing both static and dynamic characteristics of the mirrors. The latter capability was used, with the aid of a vibration stinger applying a low-level input force, to measure the dynamic characteristic changes of the PM backplane structure. This paper describes the CoC test setup, an innovative alignment method, and both static and dynamic test results.
ATLAST ULE mirror segment performance analytical predictions based on thermally induced distortions
NASA Astrophysics Data System (ADS)
Eisenhower, Michael J.; Cohen, Lester M.; Feinberg, Lee D.; Matthews, Gary W.; Nissen, Joel A.; Park, Sang C.; Peabody, Hume L.
2015-09-01
The Advanced Technology Large-Aperture Space Telescope (ATLAST) is a concept for a 9.2 m aperture space-borne observatory operating across the UV/Optical/NIR spectra. The primary mirror for ATLAST is a segmented architecture with pico-meter class wavefront stability. Due to its extraordinarily low coefficient of thermal expansion, a leading candidate for the primary mirror substrate is Corning's ULE® titania-silicate glass. The ATLAST ULE® mirror substrates will be maintained at `room temperature' during on orbit flight operations minimizing the need for compensation of mirror deformation between the manufacturing temperature and the operational temperatures. This approach requires active thermal management to maintain operational temperature while on orbit. Furthermore, the active thermal control must be sufficiently stable to prevent time-varying thermally induced distortions in the mirror substrates. This paper describes a conceptual thermal management system for the ATLAST 9.2 m segmented mirror architecture that maintains the wavefront stability to less than 10 pico-meters/10 minutes RMS. Thermal and finite element models, analytical techniques, accuracies involved in solving the mirror figure errors, and early findings from the thermal and thermal-distortion analyses are presented.
Absolute measurements of large mirrors
NASA Astrophysics Data System (ADS)
Su, Peng
The ability to produce mirrors for large astronomical telescopes is limited by the accuracy of the systems used to test the surfaces of such mirrors. Typically the mirror surfaces are measured by comparing their actual shapes to a precision master, which may be created using combinations of mirrors, lenses, and holograms. The work presented here develops several optical testing techniques that do not rely on a large or expensive precision, master reference surface. In a sense these techniques provide absolute optical testing. The Giant Magellan Telescope (GMT) has been designed with a 350 m 2 collecting area provided by a 25 m diameter primary mirror made out from seven circular independent mirror segments. These segments create an equivalent f/0.7 paraboloidal primary mirror consisting of a central segment and six outer segments. Each of the outer segments is 8.4 m in diameter and has an off-axis aspheric shape departing 14.5 mm from the best-fitting sphere. Much of the work in this dissertation is motivated by the need to measure the surfaces or such large mirrors accurately, without relying on a large or expensive precision reference surface. One method for absolute testing describing in this dissertation uses multiple measurements relative to a reference surface that is located in different positions with respect to the test surface of interest. The test measurements are performed with an algorithm that is based on the maximum likelihood (ML) method. Some methodologies for measuring large flat surfaces in the 2 m diameter range and for measuring the GMT primary mirror segments were specifically developed. For example, the optical figure of a 1.6-m flat mirror was determined to 2 nm rms accuracy using multiple 1-meter sub-aperture measurements. The optical figure of the reference surface used in the 1-meter sub-aperture measurements was also determined to the 2 nm level. The optical test methodology for a 1.7-m off axis parabola was evaluated by moving several times the mirror under test in relation to the test system. The result was a separation of errors in the optical test system to those errors from the mirror under test. This method proved to be accurate to 12nm rms. Another absolute measurement technique discussed in this dissertation utilizes the property of a paraboloidal surface of reflecting rays parallel to its optical axis, to its focal point. We have developed a scanning pentaprism technique that exploits this geometry to measure off-axis paraboloidal mirrors such as the GMT segments. This technique was demonstrated on a 1.7 m diameter prototype and proved to have a precision of about 50 nm rms.
Hubble Space Telescope: SRM/QA observations and lessons learned
NASA Technical Reports Server (NTRS)
Rodney, George A.
1990-01-01
The Hubble Space Telescope (HST) Optical Systems Board of Investigation was established on July 2, 1990 to review, analyze, and evaluate the facts and circumstances regarding the manufacture, development, and testing of the HST Optical Telescope Assembly (OTA). Specifically, the board was tasked to ascertain what caused the spherical aberration and how it escaped notice until on-orbit operation. The error that caused the on-orbit spherical aberration in the primary mirror was traced to the assembly process of the Reflective Null Corrector, one of the three Null Correctors developed as special test equipment (STE) to measure and test the primary mirror. Therefore, the safety, reliability, maintainability, and quality assurance (SRM&QA) investigation covers the events and the overall product assurance environment during the manufacturing phase of the primary mirror and Null Correctors (from 1978 through 1981). The SRM&QA issues that were identified during the HST investigation are summarized. The crucial product assurance requirements (including nonconformance processing) for the HST are examined. The history of Quality Assurance (QA) practices at Perkin-Elmer (P-E) for the period under investigation are reviewed. The importance of the information management function is discussed relative to data retention/control issues. Metrology and other critical technical issues also are discussed. The SRM&QA lessons learned from the investigation are presented along with specific recommendations. Appendix A provides the MSFC SRM&QA report. Appendix B provides supplemental reference materials. Appendix C presents the findings of the independent optical consultants, Optical Research Associates (ORA). Appendix D provides further details of the fault-tree analysis portion of the investigation process.
Cai, Chunhua; Zhang, Liangshun; Lin, Jiaping; Wang, Liquan
2008-10-09
We investigated, both experimentally and theoretically, the self-assembly behaviors of pH- and thermosensitive poly(L-glutamic acid)- b-poly(propylene oxide)-b-poly(L-glutamic acid) (PLGA-b-PPO-b-PLGA) triblock copolymers in aqueous solution by means of transmission electron microscopy (TEM), scanning electron microscopy (SEM), dynamic light scattering (DLS), circular dichroism (CD), and self-consistent field theory (SCFT) simulations. Vesicles were observed when the hydrophilic PLGA block length is shorter or the pH value of solution is lower. The vesicles were found to transform to spherical micelles when the PLGA block length increases or its conformation changes from helix to coil with increasing the pH value. In addition, increasing temperature gives rise to a decrease in the size of aggregates, which is related to the dehydration of the PPO segments at higher temperatures. The SCFT simulation results show that the vesicles transform to the spherical micelles with increasing the fraction or statistical length of A block in model ABA triblock copolymer, which corresponds to the increase in the PLGA length or its conformation change from helix to coil in experiments, respectively. The SCFT calculations also provide chain distribution information in the aggregates. On the basis of both experimental and SCFT results, the mechanism of the structure change of the PLGA- b-PPO- b-PLGA aggregates was proposed.
Goldberg-Zimring, Daniel; Talos, Ion-Florin; Bhagwat, Jui G.; Haker, Steven J.; Black, Peter M.; Zou, Kelly H.
2005-01-01
Rationale and Objectives Surgical planning now routinely uses both two-dimensional (2D) and three-dimensional (3D) models that integrate data from multiple imaging modalities, each highlighting one or more aspects of morphology or function. We performed a preliminary evaluation of the use of spherical harmonics (SH) in approximating the 3D shape and estimating the volume of brain tumors of varying characteristics. Materials and Methods Magnetic resonance (MR) images from five patients with brain tumors were selected randomly from our MR-guided neurosurgical practice. Standardized mean square reconstruction errors (SMSRE) by tumor volume were measured. Validation metrics for comparing performances of the SH method against segmented contours (SC) were the dice similarity coefficient (DSC) and standardized Euclidean distance (SED) measure. Results Tumor volume range was 22413–85189 mm3, and range of number of vertices in triangulated models was 3674–6544. At SH approximations with degree of at least 30, SMSRE were within 1.66 × 10−5 mm−1. Summary measures yielded a DSC range of 0.89–0.99 (pooled median, 0.97 and significantly >0.7; P < .001) and an SED range of 0.0002–0.0028 (pooled median, 0.0005). Conclusion 3D shapes of tumors may be approximated by using SH for neurosurgical applications. PMID:15831419
Anterior Segment Ischemia after Strabismus Surgery
Göçmen, Emine Seyhan; Atalay, Yonca; Evren Kemer, Özlem; Sarıkatipoğlu, Hikmet Yavuz
2017-01-01
A 46-year-old male patient was referred to our clinic with complaints of diplopia and esotropia in his right eye that developed after a car accident. The patient had right esotropia in primary position and abduction of the right eye was totally limited. Primary deviation was over 40 prism diopters at near and distance. The patient was diagnosed with sixth nerve palsy and 18 months after trauma, he underwent right medial rectus muscle recession. Ten months after the first operation, full-thickness tendon transposition of the superior and inferior rectus muscles (with Foster suture) was performed. On the first postoperative day, slit-lamp examination revealed corneal edema, 3+ cells in the anterior chamber and an irregular pupil. According to these findings, the diagnosis was anterior segment ischemia. Treatment with 0.1/5 mL topical dexamethasone drops (16 times/day), cyclopentolate hydrochloride drops (3 times/day) and 20 mg oral fluocortolone (3 times/day) was initiated. After 1 week of treatment, corneal edema regressed and the anterior chamber was clean. Topical and systemic steroid treatment was gradually discontinued. At postoperative 1 month, the patient was orthophoric and there were no pathologic symptoms besides the irregular pupil. Anterior segment ischemia is one of the most serious complications of strabismus surgery. Despite the fact that in most cases the only remaining sequel is an irregular pupil, serious circulation deficits could lead to phthisis bulbi. Clinical properties of anterior segment ischemia should be well recognized and in especially risky cases, preventative measures should be taken. PMID:28182149
Assessment of liver function in primary biliary cirrhosis using Gd-EOB-DTPA-enhanced liver MRI.
Nilsson, Henrik; Blomqvist, Lennart; Douglas, Lena; Nordell, Anders; Jonas, Eduard
2010-10-01
Gd-EOB-DTPA (gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid) is a gadolinium-based hepatocyte-specific contrast agent for magnetic resonance imaging (MRI). The aim of this study was to determine whether the hepatic uptake and excretion of Gd-EOB-DTPA differ between patients with primary biliary cirrhosis (PBC) and healthy controls, and whether differences could be quantified. Gd-EOB-DTPA-enhanced liver MRI was performed in 20 healthy volunteers and 12 patients with PBC. The uptake of Gd-EOB-DTPA was assessed using traditional semi-quantitative parameters (C(max) , T(max) and T(1/2) ), as well as model-free parameters derived after deconvolutional analysis (hepatic extraction fraction [HEF], input-relative blood flow [irBF] and mean transit time [MTT]). In each individual, all parameters were calculated for each liver segment and the median of the segmental values was used to define a global liver median (GLM). Although the PBC patients had relatively mild disease according to their Model for End-stage Liver Disease (MELD), Child-Pugh and Mayo risk scores, they had significantly lower HEF and shorter MTT values compared with the healthy controls. These differences significantly increased with increasing MELD and Child-Pugh scores. Dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) has a potential role as an imaging-based liver function test. The high spatial resolution of MRI enables hepatic function to be assessed on segmental and sub-segmental levels. © 2010 International Hepato-Pancreato-Biliary Association.
Xiang, T X
1993-01-01
A novel combined approach of molecular dynamics (MD) and Monte Carlo simulations is developed to calculate various free-volume distributions as a function of position in a lipid bilayer membrane at 323 K. The model bilayer consists of 2 x 100 chain molecules with each chain molecule having 15 carbon segments and one head group and subject to forces restricting bond stretching, bending, and torsional motions. At a surface density of 30 A2/chain molecule, the probability density of finding effective free volume available to spherical permeants displays a distribution with two exponential components. Both pre-exponential factors, p1 and p2, remain roughly constant in the highly ordered chain region with average values of 0.012 and 0.00039 A-3, respectively, and increase to 0.049 and 0.0067 A-3 at the mid-plane. The first characteristic cavity size V1 is only weakly dependent on position in the bilayer interior with an average value of 3.4 A3, while the second characteristic cavity size V2 varies more dramatically from a plateau value of 12.9 A3 in the highly ordered chain region to 9.0 A3 in the center of the bilayer. The mean cavity shape is described in terms of a probability distribution for the angle at which the test permeant is in contact with one of and does not overlap with anyone of the chain segments in the bilayer. The results show that (a) free volume is elongated in the highly ordered chain region with its long axis normal to the bilayer interface approaching spherical symmetry in the center of the bilayer and (b) small free volume is more elongated than large free volume. The order and conformational structures relevant to the free-volume distributions are also examined. It is found that both overall and internal motions have comparable contributions to local disorder and couple strongly with each other, and the occurrence of kink defects has higher probability than predicted from an independent-transition model. Images FIGURE 1 PMID:8241390
Dieker, Hendrik-Jan; van Horssen, Elvira V; Hersbach, Ferry M R J; Brouwer, Marc A; van Boven, Ad J; van 't Hof, Arnoud W J; Aengevaeren, Wim R M; Verheugt, Freek W A; Bär, Frits W H M
2006-08-01
As of to date, the only large transportation trial comparing on-site fibrin-specific thrombolysis with transfer for primary angioplasty in patients presenting in a referral centre is the DANAMI-2 trial, with only 3% rescue angioplasty. The Holland Infarction Study (HIS) compared abciximab facilitated primary angioplasty (FP) with on-site fibrin-specific thrombolytic therapy (TT) with a liberal protocol-driven rescue angioplasty (transport to intervention centre in case < 50% ST resolution at 60 min). Patients in a referral centre without shock and < 4.5 h of chest pain presenting with ST-elevation having > or = 12 mm ST-segment shift were randomised to either strategy. Of the originally planned 900 patients only 48 were included due to suspension of financial funding. Death, recurrent MI and stroke at one year was 8% for the FP-group and 22% for the TT-group (p = 0.2). Two hours after randomisation the rates of complete ST-segment resolution (> or =70%) were 52% and 35%, respectively (p = 0.2). This prematurely discontinued randomised transportation trial shows favorable trends with respect to long-term clinical outcome and early ST-resolution for abciximab facilitated primary angioplasty. In view of the real world delays associated with interhospital transport for primary angioplasty, treatment strategies focusing on early fibrin-specific lysis with a liberal selective rescue policy are warranted.
Accident/incident bulletin : calendar year 1994
DOT National Transportation Integrated Search
1995-08-01
The FRA Guide for Preparing Accident/Incident Reports was reprinted in 1993. It : incorporates many suggestions received from representatives of various segments of the : railroad safety community. The primary goal of this revision was to improve uni...
Case report: primary acinar cell carcinoma of the liver treated with multimodality therapy
Basturk, Olca; Shia, Jinru; Klimstra, David S.; Alago, William; D’Angelica, Michael I.; Abou-Alfa, Ghassan K.; O’Reilly, Eileen M.; Lowery, Maeve A.
2017-01-01
We describe a case of primary acinar cell carcinoma (ACC) originating in the liver in a 54-year-old female, diagnosed following persistent abnormal elevated liver function. Imaging revealed two masses, one dominant lesion in the right hepatic lobe and another in segment IVA. A right hepatectomy was performed to remove the larger lesion, while the mass in segment IVA was unresectable due to its proximity to the left hepatic vein. Immunohistochemical staining showed positivity for trypsin and chymotrypsin. Postoperatively the patient underwent hepatic arterial embolization of the other unresectable lesion followed by FOLFOX chemotherapy. At 20 months from diagnosis the patient is currently under observation with a decreasing necrotic mass and no other disease evident. Based on histology, immunohistochemistry and radiological findings a diagnosis of primary ACC of the liver was made. Genomic assessment of somatic mutations within the patient’s tumor was also performed through next generation sequencing and findings were consistent with an acinar malignancy. This case highlights a rare tumor subtype treated with a combination of therapeutic modalities through a multidisciplinary approach. PMID:29184698
Kaymaz, Cihangir; Keleş, Nurşen; Özdemir, Nihal; Tanboğa, İbrahim Halil; Demircan, Hacer C; Can, Mehmet M; Koca, Fatih; İzgi, İbrahim Akın; Özkan, Alper; Türkmen, Muhsin; Kırma, Cevat; Esen, Ali M
2015-11-01
The present study was designed to determine the effects of tirofiban (Tiro) infusion on angiographic measures, ST-segment resolution, and clinical outcomes in patients with STEMI undergoing PCI. Glycoprotein (GP) IIb/IIIa inhibitors are beneficial in ST-segment elevation myocardial infarction (STEMI) patients undergoing percutaneous coronary intervention (PCI), while the most effective timing of administration is still under investigation. A total of 1242 patients (83.0% males, mean (standard deviation; SD) age: 54.7 (10.9) years) with STEMI who underwent primary PCI were included in this retrospective non-randomized study in four groups, composed of no tirofiban infusion [Tiro (-); n=248], tirofiban infusion before PCI (pre-Tiro; n=720), tirofiban infusion during PCI (peri-Tiro; n=50), and tirofiban infusion after PCI (post-Tiro; n=224). In all Tiro (+) patients, bolus administration of Tiro (10 µg/kg) was followed by infusion (0.15 µg/kg/min) for a mean (SD) duration of 22.4±6.8 hours. The pre-PCI Tiro group was associated with the highest percentage of patients with TIMI 3 flow (99.4%; p<0.001), the lowest corrected TIMI frame count [21(18-23.4); p<0.001], the highest percentage of patients with >75% ST-segment resolution (78.1%; p<0.001), and the lowest rate of in-hospital sudden cardiac death and in-hospital all-cause mortality (3.2%, p<0.05, 3.3%, p=0.01). Major bleeding was reported in 18 (1.8%) patients who received tirofiban. Use of standard-dose bolus tirofiban in addition to aspirin, high-dose clopidogrel, and unfractionated heparin prior to primary PCI significantly improves myocardial reperfusion, ST-segment resolution, in-hospital mortality rate, and in-hospital sudden cardiac death in patients with STEMI with no increased risk of major bleeding.
The laryngeal primordium and epithelial lamina. A new interpretation.
Sañudo, J R; Domenech-Mateu, J M
1990-01-01
The laryngeal primordium is present in both the laryngotracheal sulcus (LTS) and the primitive pulmonary sac (PPS). Its early period of development may be subdivided into two phases. The first phase (Stage 11) is represented by what is traditionally referred to as the LTS, located directly beneath the PP4 on the ventral wall of the foregut (primary segment), and by the PPS which is situated at its caudal end. The LTS will represent the primordium of the upper or membranous infraglottic cavity region; whereas the PPS, will give rise not only to the bronchial tree, but also to the primordium of the trachea and the lower or cartilaginous region of the infraglottic cavity. The second phase (Stages 13 and 14) is distinguished by the cranial growth of the LTS above the PP4 and therefore by its absorption into the floor of the primitive pharynx in the mesobranchial area (secondary segment), which will develop into the primordium of the vestibule of the larynx. Similarly, we observed that in the development of the laryngeal cavity there are two temporally and spatially separate epithelial structures: the epithelial septum and the epithelial lamina. In this respect we differ from other authors who are of the opinion that there is a single structure (the epithelial lamina). The epithelial septum is a primary structure responsible for the final configuration of the LTS, as it contributes to the development of the lower end of the primary segment of the LTS and also to the creation of the secondary segment. The epithelial lamina is a secondary structure which appears inside the LTS as a result of pressure exerted by the mesenchyme on its lateral walls, without having any effect on the morphogenesis of the LTS. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 PMID:2081706
Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy
Balakrishna, Nagalla
2017-01-01
Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91. PMID:29151682
Dogan, Soner; Kastelein, Johannes Jacob Pieter; Grobbee, Diederick Egbertus; Bots, Michiel Leonardus
2011-01-01
Carotid intima-media thickness (CIMT) measurements are used as a disease outcome in randomized controlled trials that assess the effects of lipid-modifying treatment. It is unclear whether common CIMT or mean maximum CIMT should be used as the primary outcome. We directly compared both measurements using aspects that are of great importance in deciding which is most favorable for use in clinical trials. A literature search was performed (PUBMED, up to March 31, 2008). Fifteen trials with lipid-modifying treatment were identified that had information on both outcome measures. Common CIMT and mean maximum CIMT were compared on reproducibility, strength of relation with LDL and HDL cholesterol and congruency of their results (harm/neutral/beneficial) with data from event trials. Findings showed that the reported reproducibility was high for both measurements, although a direct comparison was not possible. The relationship between the achieved LDL-C and HDL-C levels with CIMT progression was modest and showed no difference in magnitude between CIMT measurements. CIMT progression rates differed across carotid segments with the highest progression rates observed in the bifurcation segment. Treatment effects differed across carotid segments without a clear preference pattern. Trials using mean maximum CIMT progression more often (12 out of 15 studies) paralleled the findings of event trials in contrast to the mean common CIMT (11 out of 15 studies), a difference not reaching statistical significance. Based on the literature, with equal results for reproducibility (assumed), lipid relationship and congruency with event findings, but with treatment effects that differ across carotid segments that can not be predicted, the mean maximum CIMT as the primary outcome may be preferred in trials on the impact of lipid-modifying interventions. One advantage is that information on mean common CIMT can generally be obtained easily in protocols assessing mean maximum CIMT, but not the other way around.
A deployable telescope for sub-meter resolutions from microsatellite platforms
NASA Astrophysics Data System (ADS)
Dolkens, D.; Kuiper, J. M.
2017-11-01
Sub-meter resolution imagery has become increasingly important for disaster response, defence and security applications. Earth Observation (EO) at these resolutions has long been the realm of large and heavy telescopes, which results in high image costs, limited availability and long revisit times. Using synthetic aperture technology, instruments can now be developed that can reach these resolutions using a substantially smaller launch volume and mass. To obtain a competitive MicroSatellite telescope design, a concept study was performed to develop a deployable instrument that can reach a ground resolution of 25 cm from an orbital altitude of 500 km. Two classes of instruments were analysed: the Fizeau synthetic aperture, a telescope that uses a segmented primary mirror, and a Michelson synthetic aperture, an instrument concept that combines the light of a distributed array of afocal telescopes into a final image. In a trade-off the Fizeau synthetic aperture was selected as the most promising concept for obtaining high resolution imagery from a Low Earth Orbit. The optical design of the Fizeau synthetic aperture is based on a full-field Korsch telescope that has been optimized for compactness and an excellent wavefront quality. It uses three aperture segments in a tri-arm configuration that can be folded alongside the instrument during launch. The secondary mirror is mounted on a deployable boom, further decreasing the launch volume. To maintain a high image quality while operating in the harsh and dynamic space environment, one of the most challenging obstacles that must be addressed is the very tight tolerance on the positioning of the three primary mirror segments and the secondary mirror. Following a sensitivity analysis, systems engineering budgets have been defined. The instrument concept features a robust thermo-mechanical design, aimed at reducing the mechanical uncertainties to a minimum. Silicon Carbide mirror segments, the use of Invar for the deployable arms and a main housing with active thermal control, will guarantee a high thermal stability during operations. Since a robust mechanical design alone is insufficient to ensure a diffraction limited performance, an inorbit calibration system was developed. Post launch, a combination of interferometric measurements and capacitive sensors will be used to characterise the system. Actuators beneath the primary mirror segments will then correct the position of the mirror segments to meet the required operating accuracies. During operations, a passive system will be used. This system relies on a phase diversity algorithm to retrieve residual wavefront aberrations and deconvolve the image data. Using this approach, a good end-to-end imaging performance can be achieved.
Lu, Hongwei; Zhang, Chenxi; Sun, Ying; Hao, Zhidong; Wang, Chunfang; Tian, Jiajia
2015-08-01
Predicting the termination of paroxysmal atrial fibrillation (AF) may provide a signal to decide whether there is a need to intervene the AF timely. We proposed a novel RdR RR intervals scatter plot in our study. The abscissa of the RdR scatter plot was set to RR intervals and the ordinate was set as the difference between successive RR intervals. The RdR scatter plot includes information of RR intervals and difference between successive RR intervals, which captures more heart rate variability (HRV) information. By RdR scatter plot analysis of one minute RR intervals for 50 segments with non-terminating AF and immediately terminating AF, it was found that the points in RdR scatter plot of non-terminating AF were more decentralized than the ones of immediately terminating AF. By dividing the RdR scatter plot into uniform grids and counting the number of non-empty grids, non-terminating AF and immediately terminating AF segments were differentiated. By utilizing 49 RR intervals, for 20 segments of learning set, 17 segments were correctly detected, and for 30 segments of test set, 20 segments were detected. While utilizing 66 RR intervals, for 18 segments of learning set, 16 segments were correctly detected, and for 28 segments of test set, 20 segments were detected. The results demonstrated that during the last one minute before the termination of paroxysmal AF, the variance of the RR intervals and the difference of the neighboring two RR intervals became smaller. The termination of paroxysmal AF could be successfully predicted by utilizing the RdR scatter plot, while the predicting accuracy should be further improved.
Lupi, Alessandro; Schaffer, Alon; Lazzero, Maurizio; Tessitori, Massimo; De Martino, Leonardo; Rognoni, Andrea; Bongo, Angelo S; Porto, Italo
2016-12-01
Pre-hospital ticagrelor, given less than 1h before coronary intervention (PCI), failed to improve coronary reperfusion in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary PCI. It is unknown whether a longer interval from ticagrelor administration to primary PCI might reveal any improvement of coronary reperfusion. We retrospectively compared 143 patients, pre-treated in spoke centers or ambulance with ticagrelor at least 1.5h before PCI (Pre-treatment Group), with 143 propensity score-matched controls treated with ticagrelor in the hub before primary PCI (Control Group) extracted from RENOVAMI, a large observational Italian registry of more than 1400 STEMI patients enrolled from Jan. 2012 to Oct. 2015 (ClinicalTrials.gov id: NCT01347580). The median time from ticagrelor administration and PCI was 2.08h (95% CI 1.66-2.84) in the Pre-treatment Group and 0.56h (95% CI 0.33-0.76) in the Control Group. TIMI flow grade before primary PCI in the infarct related artery was the primary endpoint. The primary endpoint, baseline TIMI flow grade, was significantly higher in Pre-treatment Group (0.88±1.14 vs 0.53±0.86, P=0.02). However in-hospital mortality, in-hospital stent thrombosis, bleeding rates and other clinical and angiographic outcomes were similar in the two groups. In a real world STEMI network, pre-treatment with ticagrelor in spoke hospitals or in ambulance loading at least 1.5h before primary PCI is safe and might improve pre-PCI coronary reperfusion, in comparison with ticagrelor administration immediately before PCI. Copyright © 2016 Elsevier Inc. All rights reserved.
McCabe, James M; Kennedy, Kevin F; Eisenhauer, Andrew C; Waldman, Howard M; Mort, Elizabeth A; Pomerantsev, Eugene; Resnic, Frederic S; Yeh, Robert W
2014-01-14
For patients who undergo primary percutaneous coronary intervention (PCI) for ST-segment-elevation myocardial infarction, the door-to-balloon time is an important performance measure reported to the Centers for Medicare & Medicaid Services (CMS) and tied to hospital quality assessment and reimbursement. We sought to assess the use and impact of exclusion criteria associated with the CMS measure of door-to-balloon time in primary PCI. All primary PCI-eligible patients at 3 Massachusetts hospitals (Brigham and Women's, Massachusetts General, and North Shore Medical Center) were evaluated for CMS reporting status. Rates of CMS reporting exclusion were the primary end points of interest. Key secondary end points were between-group differences in patient characteristics, door-to-balloon times, and 1-year mortality rates. From 2005 to 2011, 26% (408) of the 1548 primary PCI cases were excluded from CMS reporting. This percentage increased over the study period from 13.9% in 2005 to 36.7% in the first 3 quarters of 2011 (P<0.001). The most frequent cause of exclusion was for a diagnostic dilemma such as a nondiagnostic initial ECG, accounting for 31.2% of excluded patients. Although 95% of CMS-reported cases met door-to-balloon time goals in 2011, this was true of only 61% of CMS-excluded cases and consequently 82.6% of all primary PCI cases performed that year. The 1-year mortality for CMS-excluded patients was double that of CMS-included patients (13.5% versus 6.6%; P<0.001). More than a quarter of patients who underwent primary PCI were excluded from hospital quality reports collected by CMS, and this percentage has grown substantially over time. These findings may have significant implications for our understanding of process improvement in primary PCI and mechanisms for reimbursement through Medicare.
An image processing pipeline to detect and segment nuclei in muscle fiber microscopic images.
Guo, Yanen; Xu, Xiaoyin; Wang, Yuanyuan; Wang, Yaming; Xia, Shunren; Yang, Zhong
2014-08-01
Muscle fiber images play an important role in the medical diagnosis and treatment of many muscular diseases. The number of nuclei in skeletal muscle fiber images is a key bio-marker of the diagnosis of muscular dystrophy. In nuclei segmentation one primary challenge is to correctly separate the clustered nuclei. In this article, we developed an image processing pipeline to automatically detect, segment, and analyze nuclei in microscopic image of muscle fibers. The pipeline consists of image pre-processing, identification of isolated nuclei, identification and segmentation of clustered nuclei, and quantitative analysis. Nuclei are initially extracted from background by using local Otsu's threshold. Based on analysis of morphological features of the isolated nuclei, including their areas, compactness, and major axis lengths, a Bayesian network is trained and applied to identify isolated nuclei from clustered nuclei and artifacts in all the images. Then a two-step refined watershed algorithm is applied to segment clustered nuclei. After segmentation, the nuclei can be quantified for statistical analysis. Comparing the segmented results with those of manual analysis and an existing technique, we find that our proposed image processing pipeline achieves good performance with high accuracy and precision. The presented image processing pipeline can therefore help biologists increase their throughput and objectivity in analyzing large numbers of nuclei in muscle fiber images. © 2014 Wiley Periodicals, Inc.
Kumar, Pawan; Manjhi, Lal Bahadur; Rajak, Ramesh Lal
2013-01-01
Extruded middle segment of radius with open segmental fracture both bone forearm and dislocation of ipsilateral elbow is a rare injury. A 12-year-old child presented to us within 4 hours following fall from tree. The child's mother was carrying a 12-cm-long extruded soiled segment of radius. The extruded bone was thoroughly washed. The medullary cavity was properly syringed with antiseptic solution. The bone was autoclaved and put in the muscle plane of the distal forearm after debridement of the wound. After 5 days, a 2.5-mm K-wire was introduced by retrograde method into the proximal radius by passing through the extruded segment. Another 2.5-mm K-wire was passed in ulna. The limb was evaluated clinicoradiologically every 2 weeks. The wound was healed by primary intention. At 4 months, the reposed bone appeared less dense radiologically and K-wire seemed to be out of the bone. In the subsequent months, the roentgenograms show remodeling of the extruded fragment. After 20 weeks, the K-wires were removed (first ulnar and then radial). Complete union was achieved with full range of movement except loss of few degrees of extension of elbow and thumb. This case is reported to show a good outcome following successful incorporation of an extruded segment of radius in an open fracture. PMID:23798764
The Copenhagen problem with a quasi-homogeneous potential
NASA Astrophysics Data System (ADS)
Fakis, Demetrios; Kalvouridis, Tilemahos
2017-05-01
The Copenhagen problem is a well-known case of the famous restricted three-body problem. In this work instead of considering Newtonian potentials and forces we assume that the two primaries create a quasi-homogeneous potential, which means that we insert to the inverse square law of gravitation an inverse cube corrective term in order to approximate various phenomena as the radiation pressure of the primaries or the non-sphericity of them. Based on this new consideration we investigate the equilibrium locations of the small body and their parametric dependence, as well as the zero-velocity curves and surfaces for the planar motion, and the evolution of the regions where this motion is permitted when the Jacobian constant varies.
Low-Cost Large Aperture Telescopes for Optical Communications
NASA Technical Reports Server (NTRS)
Hemmati, Hamid
2006-01-01
Low-cost, 0.5-1 meter ground apertures are required for near-Earth laser communications. Low-cost ground apertures with equivalent diameters greater than 10 meters are desired for deep-space communications. This presentation focuses on identifying schemes to lower the cost of constructing networks of large apertures while continuing to meet the requirements for laser communications. The primary emphasis here is on the primary mirror. A slumped glass spherical mirror, along with passive secondary mirror corrector and active adaptive optic corrector show promise as a low-cost alternative to large diameter monolithic apertures. To verify the technical performance and cost estimate, development of a 1.5-meter telescope equipped with gimbal and dome is underway.
NASA Technical Reports Server (NTRS)
Jordan, T. M.
1970-01-01
The theory used in FASTER-III, a Monte Carlo computer program for the transport of neutrons and gamma rays in complex geometries, is outlined. The program includes the treatment of geometric regions bounded by quadratic and quadric surfaces with multiple radiation sources which have specified space, angle, and energy dependence. The program calculates, using importance sampling, the resulting number and energy fluxes at specified point, surface, and volume detectors. It can also calculate minimum weight shield configuration meeting a specified dose rate constraint. Results are presented for sample problems involving primary neutron, and primary and secondary photon, transport in a spherical reactor shield configuration.
Assessment of multiresolution segmentation for delimiting drumlins in digital elevation models.
Eisank, Clemens; Smith, Mike; Hillier, John
2014-06-01
Mapping or "delimiting" landforms is one of geomorphology's primary tools. Computer-based techniques such as land-surface segmentation allow the emulation of the process of manual landform delineation. Land-surface segmentation exhaustively subdivides a digital elevation model (DEM) into morphometrically-homogeneous irregularly-shaped regions, called terrain segments. Terrain segments can be created from various land-surface parameters (LSP) at multiple scales, and may therefore potentially correspond to the spatial extents of landforms such as drumlins. However, this depends on the segmentation algorithm, the parameterization, and the LSPs. In the present study we assess the widely used multiresolution segmentation (MRS) algorithm for its potential in providing terrain segments which delimit drumlins. Supervised testing was based on five 5-m DEMs that represented a set of 173 synthetic drumlins at random but representative positions in the same landscape. Five LSPs were tested, and four variants were computed for each LSP to assess the impact of median filtering of DEMs, and logarithmic transformation of LSPs. The testing scheme (1) employs MRS to partition each LSP exhaustively into 200 coarser scales of terrain segments by increasing the scale parameter ( SP ), (2) identifies the spatially best matching terrain segment for each reference drumlin, and (3) computes four segmentation accuracy metrics for quantifying the overall spatial match between drumlin segments and reference drumlins. Results of 100 tests showed that MRS tends to perform best on LSPs that are regionally derived from filtered DEMs, and then log-transformed. MRS delineated 97% of the detected drumlins at SP values between 1 and 50. Drumlin delimitation rates with values up to 50% are in line with the success of manual interpretations. Synthetic DEMs are well-suited for assessing landform quantification methods such as MRS, since subjectivity in the reference data is avoided which increases the reliability, validity and applicability of results.
Castelvecchio, Serenella; Careri, Giulia; Ambrogi, Federico; Camporeale, Antonia; Menicanti, Lorenzo; Secchi, Francesco; Lombardi, Massimo
2018-01-01
Post-infarction myocardial scar causes adverse left ventricular remodelling and negatively affects the prognosis. We sought to investigate whether scar extent and location obtained by cardiac magnetic resonance may affect the reverse remodelling and survival of heart failure patients undergoing surgical ventricular reconstruction. From January 2011 to December 2015, 151 consecutive patients with previous myocardial infarction and left ventricular remodelling underwent surgical ventricular reconstruction at our Institution, of which 88 (58%) patients had a preoperative protocol-standardized late gadolinium enhancement (LGE)-cardiac magnetic resonance examination during the week before surgery. We excluded 40 patients with devices (26%), 15 patients with irregular heart rhythm (permanent atrial fibrillation, 10% not included in the device group) or mixed contraindications (severe claustrophobia or presence of material magnetic resonance not compatible). Among the 145 survivors, 11 patients received an implantable cardioverter defibrillator after surgery (mostly for persistent low ejection fraction) and were excluded as well, yielding a total of 59 patients (48 men, aged 65 ± 9 years) who repeated a protocol-standardized LGE-cardiac magnetic resonance examination even 6 months postoperatively and therefore represent the study population. Patients were grouped according to the presence of LGE in the antero-basal left ventricular segments (Group A) or the absence of LGE in the same segments (Group B). The postoperative left ventricular end-systolic volume index was considered the primary end-point. After surgery, left ventricular end-systolic volume index and end-diastolic volume index significantly decreased (P < 0.001, for both), while diastolic sphericity index and ejection fraction significantly increased (P = 0.015 and P < 0.001, respectively). The presence of LGE in the antero-basal left ventricular segments (10 patients, Group A) was the only independent predictor of outcome (P = 0.02) at multivariate analysis, being the postoperative left ventricular end-systolic volume index significantly higher compared to that of patients of Group B (49 patients) (78 ± 26 ml/m2 vs 55 ± 20 ml/m2, P = 0.003). Furthermore, patients with a postoperative left ventricular end-systolic volume index >60 ml/m2 showed a higher risk of cardiac events (hazard ratio = 3.67, P = 0.02). In patients undergoing surgical ventricular reconstruction, LGE scar location affects the left ventricular reverse remodelling, which in turn might limit the survival benefit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Cockmartin, Lesley; Marshall, Nicholas W.; Van Ongeval, Chantal; Aerts, Gwen; Stalmans, Davina; Zanca, Federica; Shaheen, Eman; De Keyzer, Frederik; Dance, David R.; Young, Kenneth C.; Bosmans, Hilde
2015-05-01
This paper introduces a hybrid method for performing detection studies in projection image based modalities, based on image acquisitions of target objects and patients. The method was used to compare 2D mammography and digital breast tomosynthesis (DBT) in terms of the detection performance of spherical densities and microcalcifications. The method starts with the acquisition of spheres of different glandular equivalent densities and microcalcifications of different sizes immersed in a homogeneous breast tissue simulating medium. These target objects are then segmented and the subsequent templates are fused in projection images of patients and processed or reconstructed. This results in hybrid images with true mammographic anatomy and clinically relevant target objects, ready for use in observer studies. The detection study of spherical densities used 108 normal and 178 hybrid 2D and DBT images; 156 normal and 321 hybrid images were used for the microcalcifications. Seven observers scored the presence/absence of the spheres/microcalcifications in a square region via a 5-point confidence rating scale. Detection performance in 2D and DBT was compared via ROC analysis with sub-analyses for the density of the spheres, microcalcification size, breast thickness and z-position. The study was performed on a Siemens Inspiration tomosynthesis system using patient acquisitions with an average age of 58 years and an average breast thickness of 53 mm providing mean glandular doses of 1.06 mGy (2D) and 2.39 mGy (DBT). Study results showed that breast tomosynthesis (AUC = 0.973) outperformed 2D (AUC = 0.831) for the detection of spheres (p < 0.0001) and this applied for all spherical densities and breast thicknesses. By way of contrast, DBT was worse than 2D for microcalcification detection (AUC2D = 0.974, AUCDBT = 0.838, p < 0.0001), with significant differences found for all sizes (150-354 µm), for breast thicknesses above 40 mm and for heights above the detector of 20 mm and above. In conclusion, the hybrid method was successfully used to produce images for a detection study; results showed breast tomosynthesis outperformed 2D for spherical densities while further optimization of DBT for microcalcifications is suggested.
2013-10-03
fol- low the setup in the literature ([13, 14]), and use 5 (birdfall, cheetah , girl, monkeydog and parachute) of the videos for evaluation (since the...segmentation labeling results of the method, GT is the ground-truth labeling of the video, and F is the (a) Birdfall (b) Cheetah (c) Girl (d) Monkeydog...Video Ours [14] [13] [20] [6] birdfall 155 189 288 252 454 cheetah 633 806 905 1142 1217 girl 1488 1698 1785 1304 1755 monkeydog 365 472 521 563 683
High frequency magnetostrictive transducers for waveguide applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daw, Joshua Earl; Taylor, Steven Cheney; Rempe, Joy Lynn
A high frequency magnetostrictive transducer includes a magnetostrictive rod or wire inserted co-axially into a driving coil, wherein the driving coil includes a coil arrangement with a plurality of small coil segments along the magnetostrictive rod or wire; wherein frequency operation of the high frequency magnetostrictive transducer is controlled by a length of the small coil segments and a material type of the magnetostrictive rod or wire. This design of the high frequency magnetostrictive transducer retains the beneficial aspects of the magnetostrictive design, while reducing its primary drawback, lower frequency operation.
Hampton, M.A.; Karl, Herman A.; Kenyon, Neil H.
1989-01-01
Sea-floor drainage features of Cascadia Basin and the adjacent continental slope include canyons, primary fan valleys, deep-sea valleys, and remnant valley segments. Long-range sidescan sonographs and associated seismic-reflection profiles indicate that the canyons may originate along a mid-slope escarpment and grow upslope by mass wasting and downslope by valley erosion or aggradation. Most canyons are partly filled with sediment, and Quillayute Canyon is almost completely filled. Under normal growth conditions, the larger canyons connect with primary fan valleys or deep-sea valleys in Cascadia Basin, but development of accretionary ridges blocks or re-routes most canyons, forcing abandonment of the associated valleys in the basin. Astoria Fan has a primary fan valley that connects with Astoria Canyon at the fan apex. The fan valley is bordered by parallel levees on the upper fan but becomes obscure on the lower fan, where a few valley segments appear on the sonographs. Apparently, Nitinat Fan does not presently have a primary fan valley; none of the numerous valleys on the fan connect with a canyon. The Willapa-Cascadia-Vancouver-Juan de Fuca deep-sea valley system bypasses the submarine fans and includes deeply incised valleys to broad shallow swales, as well as within-valley terraces and hanging-valley confluences. ?? 1989.
30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?
Code of Federal Regulations, 2012 CFR
2012-07-01
... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...
30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?
Code of Federal Regulations, 2014 CFR
2014-07-01
... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...
30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?
Code of Federal Regulations, 2013 CFR
2013-07-01
... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...
Single-molecule Protein Unfolding in Solid State Nanopores
Talaga, David S.; Li, Jiali
2009-01-01
We use single silicon nitride nanopores to study folded, partially folded and unfolded single proteins by measuring their excluded volumes. The DNA-calibrated translocation signals of β-lactoglobulin and histidine-containing phosphocarrier protein match quantitatively with that predicted by a simple sum of the partial volumes of the amino acids in the polypeptide segment inside the pore when translocation stalls due to the primary charge sequence. Our analysis suggests that the majority of the protein molecules were linear or looped during translocation and that the electrical forces present under physiologically relevant potentials can unfold proteins. Our results show that the nanopore translocation signals are sensitive enough to distinguish the folding state of a protein and distinguish between proteins based on the excluded volume of a local segment of the polypeptide chain that transiently stalls in the nanopore due to the primary sequence of charges. PMID:19530678
[Surgical therapy of segmental jejunal, primary intestinal lymphangiectasia].
Kneist, W; Drescher, D G; Hansen, T; Kreitner, K F; Lang, H
2013-06-01
Primary intestinal lymphangiectasia (PIL) is a protein-losing, exsudative gastroenteropathy causing lymphatic obstruction. Diagnosis depends on clinical examination and histological findings. Conservative treatment modalities include a low-fat diet and enteral nutritional therapy in order to reduce enteric protein loss and to improve fat metabolism. Other treatment options consist of administration of antiplasmin or octreotide to lower lymph flow and secretion. We report on a 58-year-old patient who underwent exploratory laparotomy due to a worsening physical status, recurrent chylaskos and leg oedema under conservative dietary therapy. Intraoperative findings showed a typical PIL of the jejunum about 20 cm distal to the Treitz's ligament. Histological examinations confirmed this diagnosis. One year after segmental small bowel resection (105 cm) with end-to-end anastomosis the patient is healthy, free of symptoms, has gained weight and his serum protein level has increased. Intraabdominal ascites and leg oedema have not reoccurred since.
Patil, Sachin B; Vanikar, Aruna V; Gumber, Manoj R; Kute, Vivek B; Shah, Pankaj R; Patel, Himanshu V; Trivedi, Hargovind L
2014-01-01
Churg-Strauss syndrome (CSS) also called allergic granulomatosis and angiitis is a multisystem disorder. Churg-Strauss syndrome is defined as an eosinophil-rich, granulomatous inflammation involving the respiratory tract, along with necrotizing vasculitis affecting small- to medium-sized vessels, and is associated with asthma and eosinophilia. Renal involvement in CSS varies from 26 to 88 % but is usually of mild to moderate stage, and advanced renal failure is uncommon. We encountered an unusual case of 27-year-old man with asthma and primary focal segmental glomerulosclerosis diagnosed as CSS showing myeloperoxidase anti-neutrophil cytoplasmic antibody-associated acute kidney injury with crescentic glomerulonephritis. Patient responded to steroid and cyclophosphamide. Over a follow-up of 2 months, he has no hematuria/eosinophilia and serum creatinine of 2.3 mg/dL has decreased to 1.7 mg/dL.
Development of surface metrology for the Giant Magellan Telescope primary mirror
NASA Astrophysics Data System (ADS)
Burge, J. H.; Davison, W.; Martin, H. M.; Zhao, C.
2008-07-01
The Giant Magellan Telescope achieves 25 meter aperture and modest length using an f/0.7 primary mirror made from 8.4 meter diameter segments. The systems that will be used for measuring the aspheric optical surfaces of these mirrors are in the final phase of development. This paper discusses the overall metrology plan and shows details for the development of the principal test system - a system that uses mirrors and holograms to provide a null interferometric test of the surface. This system provides a full aperture interferometric measurement of the off-axis segments by compensating the 14.5 mm aspheric departure with a tilted 3.8-m diameter powered mirror, a 77 cm tilted mirror, and a computer generated hologram. The interferometric measurements are corroborated with a scanning slope measurement from a scanning pentaprism system and a direct measurement system based on a laser tracker.
Treacy, M P; Treacy, M G; Dimitrov, B D; Seager, F E; Stamp, M A; Murphy, C C
2013-01-01
Purpose Globally, 153 million people are visually impaired from uncorrected refractive error. The aim of this research was to verify a method whereby autorefractors could be used by non-specialist health-workers to prescribe spectacles, which used a small stock of preformed lenses that fit frames with standardised apertures. These spectacles were named S-Glasses (Smart Glasses). Patients and methods This prospective, single-cohort exploratory study enrolled 53 patients with 94 eligible eyes having uncorrected vision of 6/18 or worse. Eyes with best-corrected vision worse than 6/12 were excluded. An autorefractor was used to obtain refractions, which were adjusted so that eyes with astigmatism less than 2.00 dioptres (D) received spherical equivalent lenses, and eyes with more astigmatism received toric lenses with a 2.50 D cylindrical element set at one of four meridians. The primary outcome was to compare S-Glasses vision with the WHO definition of visual impairment (6/18). Where astigmatism was 2.00 D or greater, comparison with spherical equivalent was made. Mixed-model analysis with repeated effect was used to account for possible correlation between the vision of fellow eyes of the same individual. Results S-Glasses corrected 100% of eyes with astigmatism less than 3.00 D and 69% of eyes with astigmatism of 3.00 D or greater. Spherical equivalent lenses corrected 25% of eyes with astigmatism of 2.00−2.99 D and 11% with astigmatism of at least 3.00 D. Discussion S-Glasses could be beneficial to resource-poor populations without trained refractionists. This novel approach, using approximate toric lenses, results in superior vision for astigmatic patients compared with the practice of providing spherical equivalent alone. PMID:23306732
Advanced UVOIR Mirror Technology Development for Very Large Space Telescopes
NASA Technical Reports Server (NTRS)
Stahl, H. Philip
2011-01-01
Objective of this work is to define and initiate a long-term program to mature six inter-linked critical technologies for future UVOIR space telescope mirrors to TRL6 by 2018 so that a viable flight mission can be proposed to the 2020 Decadal Review. (1) Large-Aperture, Low Areal Density, High Stiffness Mirrors: 4 to 8 m monolithic & 8 to 16 m segmented primary mirrors require larger, thicker, stiffer substrates. (2) Support System:Large-aperture mirrors require large support systems to ensure that they survive launch and deploy on orbit in a stress-free and undistorted shape. (3) Mid/High Spatial Frequency Figure Error:A very smooth mirror is critical for producing a high-quality point spread function (PSF) for high-contrast imaging. (4) Segment Edges:Edges impact PSF for high-contrast imaging applications, contributes to stray light noise, and affects the total collecting aperture. (5) Segment-to-Segment Gap Phasing:Segment phasing is critical for producing a high-quality temporally stable PSF. (6) Integrated Model Validation:On-orbit performance is determined by mechanical and thermal stability. Future systems require validated performance models. We are pursuing multiple design paths give the science community the option to enable either a future monolithic or segmented space telescope.
James Webb Space Telescope Optical Simulation Testbed: Segmented Mirror Phase Retrieval Testing
NASA Astrophysics Data System (ADS)
Laginja, Iva; Egron, Sylvain; Brady, Greg; Soummer, Remi; Lajoie, Charles-Philippe; Bonnefois, Aurélie; Long, Joseph; Michau, Vincent; Choquet, Elodie; Ferrari, Marc; Leboulleux, Lucie; Mazoyer, Johan; N’Diaye, Mamadou; Perrin, Marshall; Petrone, Peter; Pueyo, Laurent; Sivaramakrishnan, Anand
2018-01-01
The James Webb Space Telescope (JWST) Optical Simulation Testbed (JOST) is a hardware simulator designed to produce JWST-like images. A model of the JWST three mirror anastigmat is realized with three lenses in form of a Cooke Triplet, which provides JWST-like optical quality over a field equivalent to a NIRCam module, and an Iris AO segmented mirror with hexagonal elements is standing in for the JWST segmented primary. This setup successfully produces images extremely similar to NIRCam images from cryotesting in terms of the PSF morphology and sampling relative to the diffraction limit.The testbed is used for staff training of the wavefront sensing and control (WFS&C) team and for independent analysis of WFS&C scenarios of the JWST. Algorithms like geometric phase retrieval (GPR) that may be used in flight and potential upgrades to JWST WFS&C will be explored. We report on the current status of the testbed after alignment, implementation of the segmented mirror, and testing of phase retrieval techniques.This optical bench complements other work at the Makidon laboratory at the Space Telescope Science Institute, including the investigation of coronagraphy for segmented aperture telescopes. Beyond JWST we intend to use JOST for WFS&C studies for future large segmented space telescopes such as LUVOIR.
Compensating Faraday Depolarization by Magnetic Helicity in the Solar Corona
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandenburg, Axel; Ashurova, Mohira B.; Jabbari, Sarah, E-mail: brandenb@nordita.org
A turbulent dynamo in spherical geometry with an outer corona is simulated to study the sign of magnetic helicity in the outer parts. In agreement with earlier studies, the sign in the outer corona is found to be opposite to that inside the dynamo. Line-of-sight observations of polarized emission are synthesized to explore the feasibility of using the local reduction of Faraday depolarization to infer the sign of helicity of magnetic fields in the solar corona. This approach was previously identified as an observational diagnostic in the context of galactic magnetic fields. Based on our simulations, we show that thismore » method can be successful in the solar context if sufficient statistics are gathered by using averages over ring segments in the corona separately for the regions north and south of the solar equator.« less
Weights and topology: a study of the effects of graph construction on 3D image segmentation.
Grady, Leo; Jolly, Marie-Pierre
2008-01-01
Graph-based algorithms have become increasingly popular for medical image segmentation. The fundamental process for each of these algorithms is to use the image content to generate a set of weights for the graph and then set conditions for an optimal partition of the graph with respect to these weights. To date, the heuristics used for generating the weighted graphs from image intensities have largely been ignored, while the primary focus of attention has been on the details of providing the partitioning conditions. In this paper we empirically study the effects of graph connectivity and weighting function on the quality of the segmentation results. To control for algorithm-specific effects, we employ both the Graph Cuts and Random Walker algorithms in our experiments.
Transport and Metabolism of 3H-Gibberellin A1 in Dioecious Cucumber Seedlings 1
Rudich, Jehoshua; Sell, Harold M.; Baker, Larry R.
1976-01-01
The transport of 3H-GA1 through hypocotyl segments of cucumber (Cucumis sativus L.) was found to be nonpolar. The transport of 3H-GA1 was increased by pretreatment with relatively high concentrations of either IAA or Ethephon (2-chloroethylphosphonic acid). Hypocotyl segments from plants of a gynoecious genotype transported more 3H-GA1 than those of an androecious. The metabolism of 3H-GA1 in hypocotyl segments was neither related to the sex genotype of the cucumber plant nor influenced by pretreatment with Ethephon. The primary metabolite of GA1 was suggested to be GA8. Two other suspected metabolites were not identified. Differences in the endogenous GA of gynoecious and androecious plants could not be accounted for by transport differences. PMID:16659561
Alport's syndrome with focal segmental glomerulosclerosis lesion - Pattern to recognize.
Alsahli, Afnan A; Alshahwan, Sara I; Alotaibi, Amal O; Alsaad, Khaled O; Aloudah, Nourah; Farooqui, Mahfooz; Al Sayyari, Abdullah A
2018-01-01
The association between Alport's syndrome (AS) and focal segmental glomerulosclerosis (FSGS) in the same patient is complex and rarely reported. We report a case of a 42-year-old male presenting with proteinuria, microscopic hematuria, elevated serum creatinine and hypertension with unremarkable physical examination apart from obesity. The renal biopsy showed well-established FSGS pattern of injury with mild interstitial fibrosis and tubular atrophy, while the electron microscopic examination demonstrated glomerular basement membranes (GBM) changes compatible with AS. AS can be complicated by segmental glomerular scarring, which can mimic primary FSGS, while familial FSGS can result from mutations in collagen IV network of the GBM. This overlap can complicate histopathological interpretation of renal biopsy, which should be accompanied by mutational analysis for accurate diagnosis and proper therapeutic intervention.
Active learning based segmentation of Crohns disease from abdominal MRI.
Mahapatra, Dwarikanath; Vos, Franciscus M; Buhmann, Joachim M
2016-05-01
This paper proposes a novel active learning (AL) framework, and combines it with semi supervised learning (SSL) for segmenting Crohns disease (CD) tissues from abdominal magnetic resonance (MR) images. Robust fully supervised learning (FSL) based classifiers require lots of labeled data of different disease severities. Obtaining such data is time consuming and requires considerable expertise. SSL methods use a few labeled samples, and leverage the information from many unlabeled samples to train an accurate classifier. AL queries labels of most informative samples and maximizes gain from the labeling effort. Our primary contribution is in designing a query strategy that combines novel context information with classification uncertainty and feature similarity. Combining SSL and AL gives a robust segmentation method that: (1) optimally uses few labeled samples and many unlabeled samples; and (2) requires lower training time. Experimental results show our method achieves higher segmentation accuracy than FSL methods with fewer samples and reduced training effort. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Mittlefehldt, D. W.; Gellert, R.; Ming, D. W.; Morris, R. V.; Schroeder, C.; Yen, A. S.; Farrand, W. H.; Arvidson, R. E.; Franklin, B. J.; Grant, J. A.;
2015-01-01
Mars Exploration Rover Opportunity has been exploring Meridiani Planum since January 2004, and has completed 4227% of its primary mission. Opportunity has been investigating the geology of the rim of 22 km diameter Endeavour crater, first on the Cape York segment and now on Cape Tribulation. The outcrops are divided York; (ii) the Shoemaker fm, impact breccias representing ejecta from the crater; into three formations: (i) the lower Matijevic fm, a pre-impact lithology on Cape and (iii) the upper Grasberg fm, a post-impact deposit that drapes the lower portions of the eroded rim segments. On the Cape Tribulation segment Opportunity has been studying the rocks on Murray Ridge, with a brief sojourn to Wdowiak Ridge west of the rim segment. team member Thomas Wdowiak, who died in 2013.) One region of Murray Ridge has distinctive CRISM spectral characteristics indicating the presence of a small concentration of aluminous smectite based on a 2.2 micron Al-OH combination band (hereafter, the Al-OH region).
Semi-automatic brain tumor segmentation by constrained MRFs using structural trajectories.
Zhao, Liang; Wu, Wei; Corso, Jason J
2013-01-01
Quantifying volume and growth of a brain tumor is a primary prognostic measure and hence has received much attention in the medical imaging community. Most methods have sought a fully automatic segmentation, but the variability in shape and appearance of brain tumor has limited their success and further adoption in the clinic. In reaction, we present a semi-automatic brain tumor segmentation framework for multi-channel magnetic resonance (MR) images. This framework does not require prior model construction and only requires manual labels on one automatically selected slice. All other slices are labeled by an iterative multi-label Markov random field optimization with hard constraints. Structural trajectories-the medical image analog to optical flow and 3D image over-segmentation are used to capture pixel correspondences between consecutive slices for pixel labeling. We show robustness and effectiveness through an evaluation on the 2012 MICCAI BRATS Challenge Dataset; our results indicate superior performance to baselines and demonstrate the utility of the constrained MRF formulation.
Hydrodynamic force characteristics of slender cylinders in the splash zone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haritos, N.; Daliri, M.R.
1995-12-31
This paper presents results from a pilot experimental program of research being performed on segmented vertical surface-piercing cylinders in the Department of Civil and Environmental Engineering at The University of Melbourne. The primary aim of this investigation is to determine the influence of the splash zone on the hydrodynamic force characteristics of such cylinders to wave loading in the Morison regime. This influence is assessed from a comparison of the observed force characteristics of instrumented segments located in the splash zone with the corresponding results obtained from similarly instrumented segments located in the fully submerged zone and from those obtainedmore » for the cylinder as a whole via measurements of the cylinder tip restraint force. Results to hand for uni-directional regular waves suggest that there appears to be a mild frequency dependence in the inertia force coefficient in the splash zone which only marginally exceeds the corresponding values observed for a submerged segment immediately below this zone.« less
Kosmidou, Ioanna; McAndrew, Thomas; Redfors, Björn; Embacher, Monica; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-07-19
Bradycardia on presentation is frequently observed in patients with right coronary artery ST-segment elevation myocardial infarction, but it is largely unknown whether it predicts poor angiographic or clinical outcomes in that patient population. We sought to determine the prognostic implications of admission heart rate (AHR) in patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion. We analyzed 1460 patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction) trial who underwent primary percutaneous coronary intervention. Patients presenting with high-grade atrioventricular block were excluded. Outcomes were examined according to AHR range (AHR <60, 61-79, 80-99, and ≥100 beats per minute). Baseline and procedural characteristics did not vary significantly with AHR except for a more frequent history of diabetes mellitus, longer symptom-to-balloon time, more frequent cardiogenic shock, and less frequent restoration of thrombolysis in myocardial infarction 3 flow in patients with admission tachycardia (AHR >100 beats per minute). Angiographic analysis showed no significant association between AHR and lesion location or complexity. On multivariate analysis, admission bradycardia (AHR <60 beats per minute) was not associated with increased 1-year mortality (hazard ratio 1.33; 95% CI 0.41-4.34, P =0.64) or major adverse cardiac events (hazard ratio 1.08; 95% CI 0.62-1.88, P =0.78), whereas admission tachycardia was a strong independent predictor of mortality (hazard ratio 5.02; 95% CI 1.95-12.88, P =0.0008) and major adverse cardiac events (hazard ratio 2.20; 95% CI 1.29-3.75, P =0.0004). In patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion undergoing primary percutaneous coronary intervention, admission bradycardia was not associated with increased mortality or major adverse cardiac events at 1 year. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00433966. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Self-organization of silver nanoparticles forming on chemical reduction to give monodisperse spheres
NASA Astrophysics Data System (ADS)
Yakutik, I. M.; Shevchenko, G. P.
2004-09-01
It was found possible to produce monodisperse spherical silver particles using K-Na-tartrate as the reductant for Ag + in the presence of gelatin. It was shown that the silver spheres form in the process of spontaneous self-organization of 10-15 nm-sized primary particles. The conditions making it possible to control the sizes of the monodisperse spheres in the range from 150 nm to 1.5 μm were specified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Xiaokai; Jood, Priyanka; Ohta, Michihiro
2016-01-01
In this work, we demonstrate the use of high performance nanostructured PbTe-based materials in high conversion efficiency thermoelectric modules. We fabricated the samples of PbTe-2% MgTe doped with 4% Na and PbTe doped with 0.2% PbI2 with high thermoelectric figure of merit (ZT) and sintered them with Co-Fe diffusion barriers for use as p- and n-type thermoelectric legs, respectively. Transmission electron microscopy of the PbTe legs reveals two shapes of nanostructures, disk-like and spherical. The reduction in lattice thermal conductivity through nanostructuring gives a ZT of similar to 1.8 at 810 K for p-type PbTe and similar to 1.4 atmore » 750 K for n-type PbTe. Nanostructured PbTe-based module and segmented-leg module using Bi2Te3 and nanostructured PbTe were fabricated and tested with hot-side temperatures up to 873 K in a vacuum. The maximum conversion efficiency of similar to 8.8% for a temperature difference (Delta T) of 570 K and B11% for a Delta T of 590 K have been demonstrated in the nanostructured PbTe-based module and segmented Bi2Te3/nanostructured PbTe module, respectively. Three-dimensional finite-element simulations predict that the maximum conversion efficiency of the nanostructured PbTe-based module and segmented Bi2Te3/nanostructured PbTe module reaches 12.2% for a Delta T of 570 K and 15.6% for a Delta T of 590 K respectively, which could be achieved if the electrical and thermal contact between the nanostructured PbTe legs and Cu interconnecting electrodes is further improved.« less
Posterior Eye Shape Measurement With Retinal OCT Compared to MRI
Kuo, Anthony N.; Verkicharla, Pavan K.; McNabb, Ryan P.; Cheung, Carol Y.; Hilal, Saima; Farsiu, Sina; Chen, Christopher; Wong, Tien Y.; Ikram, M. Kamran; Cheng, Ching Y.; Young, Terri L.; Saw, Seang M.; Izatt, Joseph A.
2016-01-01
Purpose Posterior eye shape assessment by magnetic resonance imaging (MRI) is used to study myopia. We tested the hypothesis that optical coherence tomography (OCT), as an alternative, could measure posterior eye shape similarly to MRI. Methods Macular spectral-domain OCT and brain MRI images previously acquired as part of the Singapore Epidemiology of Eye Diseases study were analyzed. The right eye in the MRI and OCT images was automatically segmented. Optical coherence tomography segmentations were corrected for optical and display distortions requiring biometry data. The segmentations were fitted to spheres and ellipsoids to obtain the posterior eye radius of curvature (Rc) and asphericity (Qxz). The differences in Rc and Qxz measured by MRI and OCT were tested using paired t-tests. Categorical assignments of prolateness or oblateness using Qxz were compared. Results Fifty-two subjects (67.8 ± 5.6 years old) with spherical equivalent refraction from +0.50 to −5.38 were included. The mean paired difference between MRI and original OCT posterior eye Rc was 24.03 ± 46.49 mm (P = 0.0005). For corrected OCT images, the difference in Rc decreased to −0.23 ± 2.47 mm (P = 0.51). The difference between MRI and OCT asphericity, Qxz, was −0.052 ± 0.343 (P = 0.28). However, categorical agreement was only moderate (κ = 0.50). Conclusions Distortion-corrected OCT measurements of Rc and Qxz were not statistically significantly different from MRI, although the moderate categorical agreement suggests that individual differences remained. This study provides evidence that with distortion correction, noninvasive office-based OCT could potentially be used instead of MRI for the study of posterior eye shape. PMID:27409473
A 15-MHz 1-3 Piezocomposite Concave Array Transducer for Ophthalmic Imaging.
Cha, Jung Hyui; Kang, Byungwoo; Jang, Jihun; Chang, Jin Ho
2015-11-01
Because of the spherical shape of the human eye, the anterior segments of the eye, particularly the cornea and the lens, create high levels of refraction and reflection of ultrasound which negatively affect the performance of linear and convex arrays. To minimize the ultrasound energy loss, a 15-MHz concave array transducer was designed, fabricated, and characterized; its footprint is able to mesh well with the shape of the cornea. The concave array has a curvature with a radius of 15 mm and 128 elements with a 1.44- pitch. Its elevational focus and view angle are 30 mm and 72.3°, respectively, thus allowing the imaging area to cover the retinal region of interest in the posterior segment. As an active layer, a 1-3 piezocomposite was designed and fabricated in response to the bidirectional (i.e., azimuthal and elevational) curvature of the concave array and the high coupling coefficient. From the performance evaluation, it was found that the completed concave array is able to provide a center frequency of 15.95 MHz and a -6-dB fractional bandwidth of 67.8% after electrical tuning has been conducted. The crosstalk level was measured to be less than -25 dB. It was verified that the concave array is robust to the refraction and reflection from the cornea through pulse-echo testing using a custom-made eye-mimicking phantom. Furthermore, images of both the wire-target phantom and the ex vivo porcine eye were acquired by the finished concave array, which was connected to a commercial ultrasound scanner equipped with a research package. The evaluation results demonstrated that the developed concave array transducer is a possible alternative to conventional arrays for effectively imaging the posterior segment of the eye.
Invernizzi, Alessandro; Giardini, Piero; Cigada, Mario; Viola, Francesco; Staurenghi, Giovanni
2015-07-01
We analyzed by swept-source anterior segment optical coherence tomography (SS-ASOCT) the three-dimensional iris morphology in a Caucasian population, and correlated the findings with iris color, iris sectors, subject age, and sex. One eye each from consecutive healthy emmetropic (refractive spherical equivalent ± 3 diopters) volunteers were selected for the study. The enrolled eye underwent standardized anterior segment photography to assess iris color. Iris images were assessed by SS-ASOCT for volume, thickness, width, and pupil size. Sectoral variations of morphometric data among the superior, nasal, inferior, and temporal sectors were recorded. A total of 135 eyes from 57 males and 78 females, age 49 ± 17 years, fulfilled the inclusion criteria. All iris morphometric parameters varied significantly among the different sectors (all P < 0.0001). Iris total volume and thickness were significantly correlated with increasingly darker pigmentation (P < 0.0001, P = 0.0384, respectively). Neither width nor pupil diameter was influenced by iris color. Age did not affect iris volume or thickness; iris width increased and pupil diameter decreased with age (rs = 0.52, rs = -0.58, respectively). There was no effect of sex on iris volume, thickness, or pupil diameter; iris width was significantly greater in males (P = 0.007). Morphology of the iris varied by iris sector, and iris color was associated with differences in iris volume and thickness. Morphological parameter variations associated with iris color, sector, age, and sex can be used to identify pathological changes in suspect eyes. To be effective in clinical settings, construction of iris morphological databases for different ethnic and racial populations is essential.
Customer premises services market demand assessment 1980 - 2000: Volume 2
NASA Technical Reports Server (NTRS)
Gamble, R. B.; Saporta, L.; Heidenrich, G. A.
1983-01-01
Potential customer premises service (CPS), telecommunication services, potential CPS user classes, a primary research survey, comparative economics, market demand forcasts, distance distribution of traffic, segmentation of market demand, and a nationwide traffic distribution model are discussed.
Advanced Mirror Technology Development
NASA Technical Reports Server (NTRS)
Stahl, H. Philip
2017-01-01
The Advanced Mirror Technology Development (AMTD) project matures critical technologies required to enable ultra-stable 4-m-or-larger monolithic or segmented ultraviolet, optical, and infrared (UVOIR) space telescope primary-mirror assemblies for general astrophysics and ultra-high-contrast observations of exoplanets.
Design of an interferometric system for piston measurements in segmented primary mirrors
NASA Astrophysics Data System (ADS)
Arasa, Josep; Laguarta, Ferran; Pizarro, Carlos; Tomas, Nuria; Pinto, Agusti
2000-10-01
Recently, telescopes with segmented primary mirrors are becoming increasingly popular due to their ability of achieving large apertures without the inconveniences caused by the fabrication and handling of monolithic surfaces with 8m (or over) in diameter. The difference in position of each pair of adjacent segments along the local normal of their interface (called piston hereafter), however, needs to be precisely measured in order to provide a diffraction- limited image. If a system yielding the nanometric accuracy required in piston measurements worked in daylight hours, the resultant saving in observation time would be an important advance on a majority of the state-of-the-art piston measurement systems. An interferometric piston measurement instrument accomplishing such objectives has been designed starting from the usual Michelson configuration at the CD6 (Terrassa, Spain), and its final test has been carried out in the test workbench of the Instituto de Astrofisica de Canarias (IAC, Canary Islands, Spain). Its optical layout relies on projecting the reference arm of the interferometer onto one of the segments of the pair considered, along the direction of the local normal to the surface while the measurement arm is projected onto the interface which divides the pair of segments considered. The field of view and its illumination are calculated to be equivalent in both segments. The lateral shift of the fringes in both interferograms determines the piston error present. A combination of monochromatic and white light is used, in order to remove the (lambda) /2 phase ambiguities present in piston measurements without losing the required resolution in the measurement. In this paper, the optical design of this interferometric piston measurement instrument will be presented. The particular configuration used in the interferometer, the implementation of an imaging system allowing to see both the interface of the segments and the interference fringes, the effect of the extension of the source and the use of both monochromatic and whit light will be discussed. A detailed study of the wavefront errors embedded in the wavefront at different stages of the interferometer is performed. The analysis shows the validity of the design of the instrument, and some experimental results obtained at the test workbench are provided to demonstrate the ability of the instrument to perform nanometric piston measurements under daylight conditions.
NASA Astrophysics Data System (ADS)
Jiménez, A.; Morante, E.; Viera, T.; Núñez, M.; Reyes, M.
2010-07-01
European Extremely Large Telescope (E-ELT) based in 984 primary mirror segments achieving required optical performance; they must position relatively to adjacent segments with relative nanometer accuracy. CESA designed M1 Position Actuators (PACT) to comply with demanding performance requirements of EELT. Three PACT are located under each segment controlling three out of the plane degrees of freedom (tip, tilt, piston). To achieve a high linear accuracy in long operational displacements, PACT uses two stages in series. First stage based on Voice Coil Actuator (VCA) to achieve high accuracies in very short travel ranges, while second stage based on Brushless DC Motor (BLDC) provides large stroke ranges and allows positioning the first stage closer to the demanded position. A BLDC motor is used achieving a continuous smoothly movement compared to sudden jumps of a stepper. A gear box attached to the motor allows a high reduction of power consumption and provides a great challenge for sizing. PACT space envelope was reduced by means of two flat springs fixed to VCA. Its main characteristic is a low linear axial stiffness. To achieve best performance for PACT, sensors have been included in both stages. A rotary encoder is included in BLDC stage to close position/velocity control loop. An incremental optical encoder measures PACT travel range with relative nanometer accuracy and used to close the position loop of the whole actuator movement. For this purpose, four different optical sensors with different gratings will be evaluated. Control strategy show different internal closed loops that work together to achieve required performance.