Sample records for segmented-flow aseptic processing

  1. Quality comparison of continuous steam sterilization segmented-flow aseptic processing versus conventional canning of whole and sliced mushrooms.

    PubMed

    Anderson, N M; Walker, P N

    2011-08-01

    This study was carried out to investigate segmented-flow aseptic processing of particle foods. A pilot-scale continuous steam sterilization unit capable of producing shelf stable aseptically processed whole and sliced mushrooms was developed. The system utilized pressurized steam as the heating medium to achieve high temperature-short time processing conditions with high and uniform heat transfer that will enable static temperature penetration studies for process development. Segmented-flow technology produced a narrower residence time distribution than pipe-flow aseptic processing; thus, whole and sliced mushrooms were processed only as long as needed to achieve the target F₀  = 7.0 min and were not overcooked. Continuous steam sterilization segmented-flow aseptic processing produced shelf stable aseptically processed mushrooms of superior quality to conventionally canned mushrooms. When compared to conventionally canned mushrooms, aseptically processed yield (weight basis) increased 6.1% (SD = 2.9%) and 6.6% (SD = 2.2%), whiteness (L) improved 3.1% (SD = 1.9%) and 4.7% (SD = 0.7%), color difference (ΔE) improved 6.0% (SD = 1.3%) and 8.5% (SD = 1.5%), and texture improved 3.9% (SD = 1.7%) and 4.6% (SD = 4.2%), for whole and sliced mushrooms, respectively. Segmented-flow aseptic processing eliminated a separate blanching step, eliminated the unnecessary packaging of water and promoted the use of bag-in-box and other versatile aseptic packaging methods. Segmented-flow aseptic processing is capable of producing shelf stable aseptically processed particle foods of superior quality to a conventionally canned product. This unique continuous steam sterilization process eliminates the need for a separate blanching step, reduces or eliminates the need for a liquid carrier, and promotes the use of bag-in-box and other versatile aseptic packaging methods. © 2011 Institute of Food Technologists®

  2. Feasibility of utilizing bioindicators for testing microbial inactivation in sweetpotato purees processed with a continuous-flow microwave system.

    PubMed

    Brinley, T A; Dock, C N; Truong, V-D; Coronel, P; Kumar, P; Simunovic, J; Sandeep, K P; Cartwright, G D; Swartzel, K R; Jaykus, L-A

    2007-06-01

    Continuous-flow microwave heating has potential in aseptic processing of various food products, including purees from sweetpotatoes and other vegetables. Establishing the feasibility of a new processing technology for achieving commercial sterility requires evaluating microbial inactivation. This study aimed to assess the feasibility of using commercially available plastic pouches of bioindicators containing spores of Geobacillius stearothermophilus ATCC 7953 and Bacillus subtilis ATCC 35021 for evaluating the degree of microbial inactivation achieved in vegetable purees processed in a continuous-flow microwave heating unit. Sweetpotato puree seeded with the bioindicators was subjected to 3 levels of processing based on the fastest particles: undertarget process (F(0) approximately 0.65), target process (F(0) approximately 2.8), and overtarget process (F(0) approximately 10.10). After initial experiments, we found it was necessary to engineer a setup with 2 removable tubes connected to the continuous-flow microwave system to facilitate the injection of indicators into the unit without interrupting the puree flow. Using this approach, 60% of the indicators injected into the system could be recovered postprocess. Spore survival after processing, as evaluated by use of growth indicator dyes and standard plating methods, verified inactivation of the spores in sweetpotato puree. The log reduction results for B. subtilis were equivalent to the predesigned degrees of sterilization (F(0)). This study presents the first report suggesting that bioindicators such as the flexible, food-grade plastic pouches can be used for microbial validation of commercial sterilization in aseptic processing of foods using a continuous-flow microwave system.

  3. Potential application of quantitative microbiological risk assessment techniques to an aseptic-UHT process in the food industry.

    PubMed

    Pujol, Laure; Albert, Isabelle; Johnson, Nicholas Brian; Membré, Jeanne-Marie

    2013-04-01

    Aseptic ultra-high-temperature (UHT)-type processed food products (e.g., milk or soup) are ready to eat products which are consumed extensively globally due to a combination of their comparative high quality and long shelf life, with no cold chain or other preservation requirements. Due to the inherent microbial vulnerability of aseptic-UHT product formulations, the safety and stability-related performance objectives (POs) required at the end of the manufacturing process are the most demanding found in the food industry. The key determinants to achieving sterility, and which also differentiates aseptic-UHT from in-pack sterilised products, are the challenges associated with the processes of aseptic filling and sealing. This is a complex process that has traditionally been run using deterministic or empirical process settings. Quantifying the risk of microbial contamination and recontamination along the aseptic-UHT process, using the scientifically based process quantitative microbial risk assessment (QMRA), offers the possibility to improve on the currently tolerable sterility failure rate (i.e., 1 defect per 10,000 units). In addition, benefits of applying QMRA are (i) to implement process settings in a transparent and scientific manner; (ii) to develop a uniform common structure whatever the production line, leading to a harmonisation of these process settings, and; (iii) to bring elements of a cost-benefit analysis of the management measures. The objective of this article is to explore how QMRA techniques and risk management metrics may be applied to aseptic-UHT-type processed food products. In particular, the aseptic-UHT process should benefit from a number of novel mathematical and statistical concepts that have been developed in the field of QMRA. Probabilistic techniques such as Monte Carlo simulation, Bayesian inference and sensitivity analysis, should help in assessing the compliance with safety and stability-related POs set at the end of the manufacturing process. The understanding of aseptic-UHT process contamination will be extended beyond the current "as-low-as-reasonably-achievable" targets to a risk-based framework, through which current sterility performance and future process designs can be optimised. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.

    PubMed

    Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo

    2008-01-01

    Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.

  5. Magnetic thermometry in the aseptic processing of foods containing particulates (abstract)

    NASA Astrophysics Data System (ADS)

    Ghiron, Kenneth; Litchfield, Bruce

    1997-04-01

    Aseptic processing of foods has many advantages over canning, including higher efficiency, lighter packaging, better taste, and higher nutritional value. Aseptic processing is different from canning where the food and container are sterilized together. Instead, a thin stream of food is heated and the packaging is independently sterilized before the food is placed in the package. However, no aseptic processes have been successfully filed with the FDA for foods containing sizable solid particles because of uncertainties in the thermal sterilization of the particles (e.g., soup). We have demonstrated that by inserting small paramagnetic particles in the interior of the simulated and real food particles, the local temperature can be measured. With this information, any questions about the adequate sterilization of the particles can be resolved. The measurements were done by directing the food stream through a magnetic field and sensing the voltages induced in a pickup coil by the motion of the magnetized particles. Details of the equipment design and data analysis will be discussed along with an introduction to the aseptic processing of foods.

  6. [Recent advances in treatment of aseptic femoral shaft nonunion].

    PubMed

    Zhang, Wei; Chen, Hua; Tang, Peifu

    2018-05-01

    To review the recent advances in treatment of aseptic femoral shaft nonunion. The clinical studies about the treatments of aseptic femoral shaft nonunion in recent years were widely reviewed and analyzed. There are several surgical methods for aseptic femoral shaft nonunion. Due to uncertain clinical outcome, dynamization of nail should be carefully selected. The exchange nailing is suitable for the hypertrophic nonunion of the isthmal femoral shaft fracture. The exchange lateral plating is suitable for nonunion with obvious malformation. However, wave plate or dual plate should be chosen when the bone nonuinon is combined with the medial defect. The augmentation plating improves the success rate of nailing for femoral shaft nonunion, but it should be carefully selected for patients with obvious deformity or bone defect. Ilizarov technique is suitable for various bone nonunion, especially with complicated or large segmental bone defects. Induced membrane technique is also an important method for the treatment of bone nonunion with large bone defects. The clinical efficacy of the blocking screw remains to be supported by further evidence. Biological stimulants are mainly used for atrophic nonunion, and the clinical efficacy of them alone are still controversial. Due to lack of comparative studies between different surgical methods, the orthopedist should choose the appropriate treatment according to the individual situations of the patient and the types of bone nonunion.

  7. Radiation sterilization of aseptically manufactured products.

    PubMed

    Fairand, Barry P; Fidopiastis, Niki

    2010-01-01

    This paper discusses an approach for establishing a sterilization dose for an aseptically processed product after the product is in its final packaged state, in other words, terminal sterilization. It applies to aseptic processes where the fill/finish operation is conducted in a closed system using isolator or restricted access barrier technology, that is, no human intervention. The example that is given in this paper uses gamma radiation as the sterilizing agent. Other forms of radiation such as high-energy electrons or X-rays also could serve as the sterilizing agent. The proposed approach involves irradiation of the aseptically processed product at very low doses of radiation, which is possible due to the extremely low levels of bioburden that may be present on the product following a fill/finish operation. Rather than sacrificing a large number of product units that may be required to obtain a statistically significant sampling of the product for bioburden analysis and other test purposes, the test unit is a surrogate consisting of actual pharmaceutical product that was inoculated with a highly radiation-resistant micro-organism. Selection of the microorganism was based on analysis of a library of environmental monitoring data taken from the aseptic area. Because of microbial diversity between different aseptic processing facilities, selection of the test microorganism would depend on the aseptic area under study. The approach that is discussed in this paper addresses selection and preparation of the surrogate, test of sterility of the surrogate following irradiation, determination of the radiation resistance of the test microorganism, and application of the approach to calculate a sterilization dose that is less than 10 kGy. At this low dose, it may be possible to terminally sterilize radiation-sensitive pharmaceutical products, for example, those in liquid form. Additional studies are warranted to determine the general applicability of the proposed approach.

  8. OSTEOLYSIS AROUND TOTAL KNEE ARTHOPLASTY: A REVIEW OF PATHOGENETIC MECHANISMS

    PubMed Central

    Gallo, Jiri; Goodman, Stuart B.; Konttinen, Yrjö T.; Wimmer, Markus A.; Holinka, Martin

    2014-01-01

    Aseptic loosening and other wear-related complications are one of the most frequent late reasons for revision of total knee arthroplasty (TKA). Periprosthetic osteolysis (PPOL) predates aseptic loosening in many cases indicating the clinical significance of this pathogenic mechanism. A variety of implant-, surgery-, and host-related factors have been delineated to explain the development of PPOL. These factors influence the development of PPOL due to changes in mechanical stresses within the vicinity of the prosthetic device, excessive wear of the polyethylene liner, and joint fluid pressure and flow acting on the peri-implant bone. The process of aseptic loosening is initially governed by factors such as implant/limb alignment, device fixation quality, and muscle coordination/strength. Later large numbers of wear particles detached from TKAs trigger and perpetuate particle disease, as highlighted by progressive growth of inflammatory/granulomatous tissue around the joint cavity. An increased accumulation of osteoclasts at the bone-implant interface, an impairment of osteoblast function, mechanical stresses, and an increased production of joint fluid contribute to bone resorption and subsequent loosening of the implant. In addition, hypersensitivity and adverse reactions to metal debris may contribute to aseptic TKA failure but should be determined more precisely. Patient activity level appears to be the most important factor when the long-term development of PPOL is considered. Surgical technique, implant design, and material factors are the most important preventative factors because they influence both the generation of wear debris and excessive mechanical stresses. New generations of bearing surfaces and designs for TKA should carefully address these important issues in extensive preclinical studies. Currently, there is little evidence that PPOL can be prevented with pharmacological interventions. PMID:23669623

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C.

    This profile covers aseptic boxes and paper milk cartons because they are collected together in recycling programs, but statistics are given separately for each product. Aseptic boxes, more commonly known as drink boxes, are used for fruit juices and milk. Aseptic processing involves a high-temperature/short-time treatment in which liquid products are heated quickly to a temperature at which sterilization occurs. The product is then cooled and placed in a sterile container. By weight, aseptic boxes are 70% paper (used for stiffness and strength), 24% polyethylene (used in four different layers to seal the package liquid-tight), and 6% aluminum foil (usedmore » as a barrier against air and light). By weight, milk cartons are 80% paper and 20% polyethylene.« less

  10. Use of a Corona Discharge to Selectively Pattern a Hydrophilic/Hydrophobic Interface for Integrating Segmented Flow with Microchip Electrophoresis and Electrochemical Detection

    PubMed Central

    Filla, Laura A.; Kirkpatrick, Douglas C.; Martin, R. Scott

    2011-01-01

    Segmented flow in microfluidic devices involves the use of droplets that are generated either on- or off-chip. When used with off-chip sampling methods, segmented flow has been shown to prevent analyte dispersion and improve temporal resolution by periodically surrounding an aqueous flow stream with an immiscible carrier phase as it is transferred to the microchip. To analyze the droplets by methods such as electrochemistry or electrophoresis, a method to “desegment” the flow into separate aqueous and immiscible carrier phase streams is needed. In this paper, a simple and straightforward approach for this desegmentation process was developed by first creating an air/water junction in natively hydrophobic and perpendicular PDMS channels. The air-filled channel was treated with a corona discharge electrode to create a hydrophilic/hydrophobic interface. When a segmented flow stream encounters this interface, only the aqueous sample phase enters the hydrophilic channel, where it can be subsequently analyzed by electrochemistry or microchip-based electrophoresis with electrochemical detection. It is shown that the desegmentation process does not significantly degrade the temporal resolution of the system, with rise times as low as 12 s reported after droplets are recombined into a continuous flow stream. This approach demonstrates significant advantages over previous studies in that the treatment process takes only a few minutes, fabrication is relatively simple, and reversible sealing of the microchip is possible. This work should enable future studies where off-chip processes such as microdialysis can be integrated with segmented flow and electrochemical-based detection. PMID:21718004

  11. Multicenter Study on Incubation Conditions for Environmental Monitoring and Aseptic Process Simulation.

    PubMed

    Guinet, Roland; Berthoumieu, Nicole; Dutot, Philippe; Triquet, Julien; Ratajczak, Medhi; Thibaudon, Michel; Bechaud, Philippe; Arliaud, Christophe; Miclet, Edith; Giordano, Florine; Larcon, Marjorie; Arthaud, Catherine

    Environmental monitoring and aseptic process simulations represent an integral part of the microbiological quality control system of sterile pharmaceutical products manufacturing operations. However, guidance documents and manufacturers practices differ regarding recommendations for incubation time and incubation temperature, and, consequently, the environmental monitoring and aseptic process simulation incubation strategy should be supported by validation data. To avoid any bias coming from in vitro studies or from single-site manufacturing in situ studies, we performed a collaborative study at four manufacturing sites with four samples at each location. The environmental monitoring study was performed with tryptic soy agar settle plates and contact plates, and the aseptic process simulation study was performed with tryptic soy broth and thioglycolate broth. The highest recovery rate was obtained with settle plates (97.7%) followed by contact plates (65.4%) and was less than 20% for liquid media (tryptic soy broth 19% and thioglycolate broth 17%). Gram-positive cocci and non-spore-forming Gram-positive rods were largely predominant with more than 95% of growth and recovered best at 32.5 °C. The highest recovery of molds was obtained at 22.5 °C alone or as the first incubation temperature. Strict anaerobes were not recovered. At the end of the five days of incubation no significant statistical difference was obtained between the four conditions. Based on these data a single incubation temperature at 32.5 °C could be recommended for these four manufacturing sites for both environmental monitoring and aseptic process simulation, and a second plate could be used, periodically incubated at 22.5 °C. Similar studies should be considered for all manufacturing facilities in order to determine the optimal incubation temperature regime for both viable environmental monitoring and aseptic process simulation. Microbiological environmental monitoring and aseptic process simulation confirm that pharmaceutical cleanrooms are in an appropriate hygienic condition for manufacturing of sterile drug products. Guidance documents from different health authorities or expert groups differ regarding recommendation of the applied incubation time and incubation temperature, leading to variable manufacturers practices. Some recent publications have demonstrated that laboratory studies are not relevant to determine the best incubation regime and that in situ manufacturing site studies should be used. To solve any possible bias coming from laboratory studies or single-site in situ studies, we conducted a multicenter study at four manufacturing sites with a significant amount of real environmental monitoring samples collected directly from the environment in pharmaceutical production during manufacturing operations with four solid and liquid nutrient media. These samples were then incubated under four different conditions suggested in the guidance documents. We believe that the results of our multicenter study confirming recent other single-site in situ studies could be the basis of the strategy to determine the best incubation regime for both viable environmental monitoring and aseptic process simulation in any manufacturing facility. © PDA, Inc. 2017.

  12. Control and Automation of Fluid Flow, Mass Transfer and Chemical Reactions in Microscale Segmented Flow

    NASA Astrophysics Data System (ADS)

    Abolhasani, Milad

    Flowing trains of uniformly sized bubbles/droplets (i.e., segmented flows) and the associated mass transfer enhancement over their single-phase counterparts have been studied extensively during the past fifty years. Although the scaling behaviour of segmented flow formation is increasingly well understood, the predictive adjustment of the desired flow characteristics that influence the mixing and residence times, remains a challenge. Currently, a time consuming, slow and often inconsistent manual manipulation of experimental conditions is required to address this task. In my thesis, I have overcome the above-mentioned challenges and developed an experimental strategy that for the first time provided predictive control over segmented flows in a hands-off manner. A computer-controlled platform that consisted of a real-time image processing module within an integral controller, a silicon-based microreactor and automated fluid delivery technique was designed, implemented and validated. In a first part of my thesis I utilized this approach for the automated screening of physical mass transfer and solubility characteristics of carbon dioxide (CO2) in a physical solvent at a well-defined temperature and pressure and a throughput of 12 conditions per hour. Second, by applying the segmented flow approach to a recently discovered CO2 chemical absorbent, frustrated Lewis pairs (FLPs), I determined the thermodynamic characteristics of the CO2-FLP reaction. Finally, the segmented flow approach was employed for characterization and investigation of CO2-governed liquid-liquid phase separation process. The second part of my thesis utilized the segmented flow platform for the preparation and shape control of high quality colloidal nanomaterials (e.g., CdSe/CdS) via the automated control of residence times up to approximately 5 minutes. By introducing a novel oscillatory segmented flow concept, I was able to further extend the residence time limitation to 24 hours. A case study of a slow candidate reaction, the etching of gold nanorods during up to five hours, served to illustrate the utility of oscillatory segmented flows in assessing the shape evolution of colloidal nanomaterials on-chip via continuous optical interrogation at only one sensing location. The developed cruise control strategy will enable plug'n play operation of segmented flows in applications that include flow chemistry, material synthesis and in-flow analysis and screening.

  13. Media Fill Test for validation of autologous leukocytes separation and labelling by (99m)Tc-HmPAO.

    PubMed

    Urbano, Nicoletta; Modoni, Sergio; Schillaci, Orazio

    2013-01-01

    Manufacturing of sterile products must be carried out in order to minimize risks of microbiological contamination. White blood cells (WBC) labelled with (99m)Tc-exametazime ((99m)Tc-hexamethylpropyleneamine oxime; (99m)Tc-HMPAO) are being successfully applied in the field of infection/inflammation scintigraphy for many years. In our radiopharmacy lab, separation and labelling of autologous leukocytes with (99m)Tc-HMPAO were performed in a laminar flow cabinet not classified and placed in a controlled area, whereas (99m)Tc-HMPAO radiolabelling procedure was carried out in a hot cell with manipulator gloves. This study was conducted to validate this process using a Media Fill simulation test. The study was performed using sterile Tryptic Soy Broth (TSB) in place of active product, reproducing as closely as possible the routine aseptic production process with all the critical steps, as described in the our internal standard operative procedures (SOP). The final vials containing the media of each processed step were then incubated for 14 days and examined for the evidence of microbial growth. No evidence of turbidity was observed in all the steps assayed by the Media Fill. In the separation and labelling of autologous leukocytes with (99m)Tc-HmPAO, Media-Fill test represents a reliable tool to validate the aseptic process. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Automated MRI segmentation for individualized modeling of current flow in the human head.

    PubMed

    Huang, Yu; Dmochowski, Jacek P; Su, Yuzhuo; Datta, Abhishek; Rorden, Christopher; Parra, Lucas C

    2013-12-01

    High-definition transcranial direct current stimulation (HD-tDCS) and high-density electroencephalography require accurate models of current flow for precise targeting and current source reconstruction. At a minimum, such modeling must capture the idiosyncratic anatomy of the brain, cerebrospinal fluid (CSF) and skull for each individual subject. Currently, the process to build such high-resolution individualized models from structural magnetic resonance images requires labor-intensive manual segmentation, even when utilizing available automated segmentation tools. Also, accurate placement of many high-density electrodes on an individual scalp is a tedious procedure. The goal was to develop fully automated techniques to reduce the manual effort in such a modeling process. A fully automated segmentation technique based on Statical Parametric Mapping 8, including an improved tissue probability map and an automated correction routine for segmentation errors, was developed, along with an automated electrode placement tool for high-density arrays. The performance of these automated routines was evaluated against results from manual segmentation on four healthy subjects and seven stroke patients. The criteria include segmentation accuracy, the difference of current flow distributions in resulting HD-tDCS models and the optimized current flow intensities on cortical targets. The segmentation tool can segment out not just the brain but also provide accurate results for CSF, skull and other soft tissues with a field of view extending to the neck. Compared to manual results, automated segmentation deviates by only 7% and 18% for normal and stroke subjects, respectively. The predicted electric fields in the brain deviate by 12% and 29% respectively, which is well within the variability observed for various modeling choices. Finally, optimized current flow intensities on cortical targets do not differ significantly. Fully automated individualized modeling may now be feasible for large-sample EEG research studies and tDCS clinical trials.

  15. Software design specification. Part 2: Orbital Flight Test (OFT) detailed design specification. Volume 3: Applications. Book 2: System management

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The functions performed by the systems management (SM) application software are described along with the design employed to accomplish these functions. The operational sequences (OPS) control segments and the cyclic processes they control are defined. The SM specialist function control (SPEC) segments and the display controlled 'on-demand' processes that are invoked by either an OPS or SPEC control segment as a direct result of an item entry to a display are included. Each processing element in the SM application is described including an input/output table and a structured control flow diagram. The flow through the module and other information pertinent to that process and its interfaces to other processes are included.

  16. Molecular biology, pathogenesis and pathology of mumps virus

    PubMed Central

    Rubin, Steven; Eckhaus, Michael; Rennick, Linda J; Bamford, Connor GG; Duprex, W Paul

    2014-01-01

    Mumps is caused by the mumps virus (MuV), a member of the Paramyxoviridae family of enveloped, non-segmented, negative-sense RNA viruses. Mumps is characterized by painful inflammatory symptoms, such as parotitis and orchitis. The virus is highly neurotropic, with laboratory evidence of central nervous system (CNS) infection in approximately half of cases. Symptomatic CNS infection occurs less frequently; nonetheless, prior to the introduction of routine vaccination, MuV was a leading cause of aseptic meningitis and viral encephalitis in many developed countries. Despite being one of the oldest recognized diseases, with a worldwide distribution, surprisingly little attention has been given to its study. Cases of aseptic meningitis associated with some vaccine strains and a global resurgence of cases, including in highly vaccinated populations, has renewed interest in the virus, particularly in its pathogenesis and the need for development of clinically relevant models of disease. In this review we summarize the current state of knowledge on the virus, its pathogenesis and its clinical and pathological outcomes. PMID:25229387

  17. Probabilistic exposure assessment model to estimate aseptic-UHT product failure rate.

    PubMed

    Pujol, Laure; Albert, Isabelle; Magras, Catherine; Johnson, Nicholas Brian; Membré, Jeanne-Marie

    2015-01-02

    Aseptic-Ultra-High-Temperature (UHT) products are manufactured to be free of microorganisms capable of growing in the food at normal non-refrigerated conditions at which the food is likely to be held during manufacture, distribution and storage. Two important phases within the process are widely recognised as critical in controlling microbial contamination: the sterilisation steps and the following aseptic steps. Of the microbial hazards, the pathogen spore formers Clostridium botulinum and Bacillus cereus are deemed the most pertinent to be controlled. In addition, due to a relatively high thermal resistance, Geobacillus stearothermophilus spores are considered a concern for spoilage of low acid aseptic-UHT products. A probabilistic exposure assessment model has been developed in order to assess the aseptic-UHT product failure rate associated with these three bacteria. It was a Modular Process Risk Model, based on nine modules. They described: i) the microbial contamination introduced by the raw materials, either from the product (i.e. milk, cocoa and dextrose powders and water) or the packaging (i.e. bottle and sealing component), ii) the sterilisation processes, of either the product or the packaging material, iii) the possible recontamination during subsequent processing of both product and packaging. The Sterility Failure Rate (SFR) was defined as the sum of bottles contaminated for each batch, divided by the total number of bottles produced per process line run (10(6) batches simulated per process line). The SFR associated with the three bacteria was estimated at the last step of the process (i.e. after Module 9) but also after each module, allowing for the identification of modules, and responsible contamination pathways, with higher or lower intermediate SFR. The model contained 42 controlled settings associated with factory environment, process line or product formulation, and more than 55 probabilistic inputs corresponding to inputs with variability conditional to a mean uncertainty. It was developed in @Risk and run through Monte Carlo simulations. Overall, the highest SFR was associated with G. stearothermophilus (380000 bottles contaminated in 10(11) bottles produced) and the lowest to C. botulinum (3 bottles contaminated in 10(11) bottles produced). Unsurprisingly, SFR due to G. stearothermophilus was due to its ability to survive the UHT treatment. More interestingly, it was identified that SFR due to B. cereus (17000 bottles contaminated in 10(11) bottles produced) was due to an airborne recontamination of the aseptic tank (49%) and a post-sterilisation packaging contamination (33%). A deeper analysis (sensitivity and scenario analyses) was done to investigate how the SFR due to B. cereus could be reduced by changing the process settings related to potential air recontamination source. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Engine Hydraulic Stability. [injector model for analyzing combustion instability

    NASA Technical Reports Server (NTRS)

    Kesselring, R. C.; Sprouse, K. M.

    1977-01-01

    An analytical injector model was developed specifically to analyze combustion instability coupling between the injector hydraulics and the combustion process. This digital computer dynamic injector model will, for any imposed chamber of inlet pressure profile with a frequency ranging from 100 to 3000 Hz (minimum) accurately predict/calculate the instantaneous injector flowrates. The injector system is described in terms of which flow segments enter and leave each pressure node. For each flow segment, a resistance, line lengths, and areas are required as inputs (the line lengths and areas are used in determining inertance). For each pressure node, volume and acoustic velocity are required as inputs (volume and acoustic velocity determine capacitance). The geometric criteria for determining inertances of flow segments and capacitance of pressure nodes was set. Also, a technique was developed for analytically determining time averaged steady-state pressure drops and flowrates for every flow segment in an injector when such data is not known. These pressure drops and flowrates are then used in determining the linearized flow resistance for each line segment of flow.

  19. Automated MRI Segmentation for Individualized Modeling of Current Flow in the Human Head

    PubMed Central

    Huang, Yu; Dmochowski, Jacek P.; Su, Yuzhuo; Datta, Abhishek; Rorden, Christopher; Parra, Lucas C.

    2013-01-01

    Objective High-definition transcranial direct current stimulation (HD-tDCS) and high-density electroencephalography (HD-EEG) require accurate models of current flow for precise targeting and current source reconstruction. At a minimum, such modeling must capture the idiosyncratic anatomy of brain, cerebrospinal fluid (CSF) and skull for each individual subject. Currently, the process to build such high-resolution individualized models from structural magnetic resonance images (MRI) requires labor-intensive manual segmentation, even when leveraging available automated segmentation tools. Also, accurate placement of many high-density electrodes on individual scalp is a tedious procedure. The goal was to develop fully automated techniques to reduce the manual effort in such a modeling process. Approach A fully automated segmentation technique based on Statical Parametric Mapping 8 (SPM8), including an improved tissue probability map (TPM) and an automated correction routine for segmentation errors, was developed, along with an automated electrode placement tool for high-density arrays. The performance of these automated routines was evaluated against results from manual segmentation on 4 healthy subjects and 7 stroke patients. The criteria include segmentation accuracy, the difference of current flow distributions in resulting HD-tDCS models and the optimized current flow intensities on cortical targets. Main results The segmentation tool can segment out not just the brain but also provide accurate results for CSF, skull and other soft tissues with a field of view (FOV) extending to the neck. Compared to manual results, automated segmentation deviates by only 7% and 18% for normal and stroke subjects, respectively. The predicted electric fields in the brain deviate by 12% and 29% respectively, which is well within the variability observed for various modeling choices. Finally, optimized current flow intensities on cortical targets do not differ significantly. Significance Fully automated individualized modeling may now be feasible for large-sample EEG research studies and tDCS clinical trials. PMID:24099977

  20. Automated MRI segmentation for individualized modeling of current flow in the human head

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Dmochowski, Jacek P.; Su, Yuzhuo; Datta, Abhishek; Rorden, Christopher; Parra, Lucas C.

    2013-12-01

    Objective. High-definition transcranial direct current stimulation (HD-tDCS) and high-density electroencephalography require accurate models of current flow for precise targeting and current source reconstruction. At a minimum, such modeling must capture the idiosyncratic anatomy of the brain, cerebrospinal fluid (CSF) and skull for each individual subject. Currently, the process to build such high-resolution individualized models from structural magnetic resonance images requires labor-intensive manual segmentation, even when utilizing available automated segmentation tools. Also, accurate placement of many high-density electrodes on an individual scalp is a tedious procedure. The goal was to develop fully automated techniques to reduce the manual effort in such a modeling process. Approach. A fully automated segmentation technique based on Statical Parametric Mapping 8, including an improved tissue probability map and an automated correction routine for segmentation errors, was developed, along with an automated electrode placement tool for high-density arrays. The performance of these automated routines was evaluated against results from manual segmentation on four healthy subjects and seven stroke patients. The criteria include segmentation accuracy, the difference of current flow distributions in resulting HD-tDCS models and the optimized current flow intensities on cortical targets.Main results. The segmentation tool can segment out not just the brain but also provide accurate results for CSF, skull and other soft tissues with a field of view extending to the neck. Compared to manual results, automated segmentation deviates by only 7% and 18% for normal and stroke subjects, respectively. The predicted electric fields in the brain deviate by 12% and 29% respectively, which is well within the variability observed for various modeling choices. Finally, optimized current flow intensities on cortical targets do not differ significantly.Significance. Fully automated individualized modeling may now be feasible for large-sample EEG research studies and tDCS clinical trials.

  1. [Recurrent aseptic meningitis secondary to taking ibuprofen and ketorolac].

    PubMed

    Cano Vargas-Machuca, E; Mondéjar-Marín, B; Navarro-Muñoz, S; Pérez-Molina, I; Garrido-Robres, J A; Alvarez-Tejerina, A

    Aseptic meningitis is a process that is characterised by an inflammatory reaction of the meninges that is not due to any infectious agent. Its aetiology is varied and is most frequently caused by rheumatologic and/or autoimmune processes, chemical or medication-induced meningitis, the most notable drugs involved being antibiotics and non-steroidal anti-inflammatory drugs (NSAI). We report the case of a 70-year-old male, with no relevant history, who was admitted to hospital five times over a period of 16 months because of acute meningitis with polymorphonuclear pleocytosis, high protein levels in cerebrospinal fluid and normal glucose in cerebrospinal fluid. No evidence of an infectious causation, chemical meningitis, carcinomatosis or autoimmune disease was found and the patient was diagnosed with recurrent aseptic meningitis. It was found that the patient had taken ibuprofen or ketorolac on several occasions, a few hours before the appearance of symptoms. These episodes were quickly resolved after withdrawal of this medication. A number of NSAI have been reported as inducers of aseptic meningitis, one of the most notable being ibuprofen. We report the case of a patient who, as a consequence of taking ibuprofen and ketorolac, presented episodes of recurrent aseptic meningitis. To our knowledge this side effect of ketorolac has not been reported before. Its clinical features are impossible to differentiate from those of infectious meningitis. Diagnosis is reached by exclusion and a careful pharmacological study, including over-the-counter drugs like some of the NSAI, must be performed in patients with this condition, since it is a problem that can easily be solved by withdrawing the drug that causes it.

  2. Understanding the topological characteristics and flow complexity of urban traffic congestion

    NASA Astrophysics Data System (ADS)

    Wen, Tzai-Hung; Chin, Wei-Chien-Benny; Lai, Pei-Chun

    2017-05-01

    For a growing number of developing cities, the capacities of streets cannot meet the rapidly growing demand of cars, causing traffic congestion. Understanding the spatial-temporal process of traffic flow and detecting traffic congestion are important issues associated with developing sustainable urban policies to resolve congestion. Therefore, the objective of this study is to propose a flow-based ranking algorithm for investigating traffic demands in terms of the attractiveness of street segments and flow complexity of the street network based on turning probability. Our results show that, by analyzing the topological characteristics of streets and volume data for a small fraction of street segments in Taipei City, the most congested segments of the city were identified successfully. The identified congested segments are significantly close to the potential congestion zones, including the officially announced most congested streets, the segments with slow moving speeds at rush hours, and the areas near significant landmarks. The identified congested segments also captured congestion-prone areas concentrated in the business districts and industrial areas of the city. Identifying the topological characteristics and flow complexity of traffic congestion provides network topological insights for sustainable urban planning, and these characteristics can be used to further understand congestion propagation.

  3. Apparatus and method for ultrasonic treatment of a liquid

    DOEpatents

    Chandler, Darrell P.; Posakony, Gerald J.; Bond, Leonard J.; Bruckner-Lea, Cynthia J.

    2006-04-04

    The present invention is an apparatus for ultrasonically treating a liquid to generate a product. The apparatus is capable of treating a continuously-flowing, or intermittently-flowing, liquid along a line segment coincident with the flow path of the liquid. The apparatus has one or more ultrasonic transducers positioned asymmetrically about the line segment. The ultrasonic field encompasses the line segment and the ultrasonic energy may be concentrated along the line segment. Lysing treatments have been successfully achieved with efficiencies of greater than 99% using ultrasound at MHz frequencies without erosion or heating problems and without the need for chemical or mechanical pretreatment, or contrast agents. The present invention overcomes drawbacks of current ultrasonic treatments beyond lysing and opens up new sonochemical and sonophysical processing opportunities.

  4. Estimation and evaluation of management options to control and/or reduce the risk of not complying with commercial sterility.

    PubMed

    Pujol, Laure; Albert, Isabelle; Magras, Catherine; Johnson, Nicholas Brian; Membré, Jeanne-Marie

    2015-11-20

    In a previous study, a modular process risk model, from the raw material reception to the final product storage, was built to estimate the risk of a UHT-aseptic line of not complying with commercial sterility (Pujol et al., 2015). This present study was focused on demonstrating how the model (updated version with uncertainty and variability separated and 2(nd) order Monte Carlo procedure run) could be used to assess quantitatively the influence of management options. This assessment was done in three steps: pinpoint which process step had the highest influence on the risk, identify which management option(s) could be the most effective to control and/or reduce the risk, and finally evaluate quantitatively the influence of changing process setting(s) on the risk. For Bacillus cereus, it was identified that during post-process storage in an aseptic tank, there was potentially an air re-contamination due to filter efficiency loss (efficiency loss due to successive in-place sterilizations after cleaning operations), followed by B. cereus growth. Two options were then evaluated: i) reducing by one fifth of the number of filter sterilizations before renewing the filters, ii) designing new UHT-aseptic lines without an aseptic tank, i.e. without a storage period after the thermal process and before filling. Considering the uncertainty in the model, it was not possible to confirm whether these options had a significant influence on the risk associated with B. cereus. On the other hand, for Geobacillus stearothermophilus, combinations of heat-treatment time and temperature enabling the control or reduction in risk by a factor of ca. 100 were determined; for ease of operational implementation, they were presented graphically in the form of iso-risk curves. For instance, it was established that a heat treatment of 138°C for 31s (instead of 138°C for 25s) enabled a reduction in risk to 18×10(-8) (95% CI=[10; 34]×10(-8)), instead of 578×10(-8) (95% CI=[429; 754]×10(-8)) initially. In conclusion, a modular risk model, as the one exemplified here with a UHT-aseptic line, is a valuable tool in process design and operation, bringing definitive quantitative elements into the decision making process. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Segmenting Dynamic Human Action via Statistical Structure

    ERIC Educational Resources Information Center

    Baldwin, Dare; Andersson, Annika; Saffran, Jenny; Meyer, Meredith

    2008-01-01

    Human social, cognitive, and linguistic functioning depends on skills for rapidly processing action. Identifying distinct acts within the dynamic motion flow is one basic component of action processing; for example, skill at segmenting action is foundational to action categorization, verb learning, and comprehension of novel action sequences. Yet…

  6. Crowd motion segmentation and behavior recognition fusing streak flow and collectiveness

    NASA Astrophysics Data System (ADS)

    Gao, Mingliang; Jiang, Jun; Shen, Jin; Zou, Guofeng; Fu, Guixia

    2018-04-01

    Crowd motion segmentation and crowd behavior recognition are two hot issues in computer vision. A number of methods have been proposed to tackle these two problems. Among the methods, flow dynamics is utilized to model the crowd motion, with little consideration of collective property. Moreover, the traditional crowd behavior recognition methods treat the local feature and dynamic feature separately and overlook the interconnection of topological and dynamical heterogeneity in complex crowd processes. A crowd motion segmentation method and a crowd behavior recognition method are proposed based on streak flow and crowd collectiveness. The streak flow is adopted to reveal the dynamical property of crowd motion, and the collectiveness is incorporated to reveal the structure property. Experimental results show that the proposed methods improve the crowd motion segmentation accuracy and the crowd recognition rates compared with the state-of-the-art methods.

  7. Apparatus and method for ultrasonic treatment of a liquid

    DOEpatents

    Chandler, Darrell P [Richland, WA; Posakony, Gerald J [Richland, WA; Bond, Leonard J [Richland, WA; Bruckner-Lea, Cynthia J [Richland, WA

    2003-01-14

    The present invention is an apparatus and method for ultrasonically treating a liquid to generate a product. The apparatus is capable of treating a continuously-flowing, or intermittently-flowing, liquid along a line segment coincident with the flow path of the liquid. The apparatus has one or more ultrasonic transducers positioned asymmetrically about the line segment. The ultrasonic field encompasses the line segment and the ultrasonic energy may be concentrated along the line segment. Lysing treatments have been successfully achieved with efficiencies of greater than 99% using ultrasound at MHz frequencies without erosion or heating problems and without the need for chemical or mechanical pretreatment, or contrast agents. The present invention overcomes drawbacks of current ultrasonic treatments beyond lysing and opens up new sonochemical and sonophysical processing opportunities.

  8. Molecular biology, pathogenesis and pathology of mumps virus.

    PubMed

    Rubin, Steven; Eckhaus, Michael; Rennick, Linda J; Bamford, Connor G G; Duprex, W Paul

    2015-01-01

    Mumps is caused by the mumps virus (MuV), a member of the Paramyxoviridae family of enveloped, non-segmented, negative-sense RNA viruses. Mumps is characterized by painful inflammatory symptoms, such as parotitis and orchitis. The virus is highly neurotropic, with laboratory evidence of central nervous system (CNS) infection in approximately half of cases. Symptomatic CNS infection occurs less frequently; nonetheless, prior to the introduction of routine vaccination, MuV was a leading cause of aseptic meningitis and viral encephalitis in many developed countries. Despite being one of the oldest recognized diseases, with a worldwide distribution, surprisingly little attention has been given to its study. Cases of aseptic meningitis associated with some vaccine strains and a global resurgence of cases, including in highly vaccinated populations, has renewed interest in the virus, particularly in its pathogenesis and the need for development of clinically relevant models of disease. In this review we summarize the current state of knowledge on the virus, its pathogenesis and its clinical and pathological outcomes. Copyright © 2014 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  9. Highly Segmented Thermal Barrier Coatings Deposited by Suspension Plasma Spray: Effects of Spray Process on Microstructure

    NASA Astrophysics Data System (ADS)

    Chen, Xiaolong; Honda, Hiroshi; Kuroda, Seiji; Araki, Hiroshi; Murakami, Hideyuki; Watanabe, Makoto; Sakka, Yoshio

    2016-12-01

    Effects of the ceramic powder size used for suspension as well as several processing parameters in suspension plasma spraying of YSZ were investigated experimentally, aiming to fabricate highly segmented microstructures for thermal barrier coating (TBC) applications. Particle image velocimetry (PIV) was used to observe the atomization process and the velocity distribution of atomized droplets and ceramic particles travelling toward the substrates. The tested parameters included the secondary plasma gas (He versus H2), suspension injection flow rate, and substrate surface roughness. Results indicated that a plasma jet with a relatively higher content of He or H2 as the secondary plasma gas was critical to produce highly segmented YSZ TBCs with a crack density up to 12 cracks/mm. The optimized suspension flow rate played an important role to realize coatings with a reduced porosity level and improved adhesion. An increased powder size and higher operation power level were beneficial for the formation of highly segmented coatings onto substrates with a wider range of surface roughness.

  10. Loading and unloading of freeze-dryers: airborne contamination risks for aseptically manufactured sterile drug products.

    PubMed

    Ljungqvist, Bengt; Reinmüller, Berit

    2007-01-01

    In pharmaceutical manufacturing, freeze-drying processes can be adversely affected by temperature differences relative to the surrounding air. Loading and unloading of freeze-dryers are performed either without or with temperature differences between the cleanroom and the chamber of the freeze-dryer. This operation can cause a flow of room air through the opening, creating a contamination risk, especially when manual handling of material is performed in this area. To minimize this risk, a high-efficiency particulate air (HEPA) filter unit should be installed above the opening to provide clean air and protect the opening. Here the theoretical relationships are discussed and design criteria are presented.

  11. [Aseptic process validation and stability study of an injectable preparation of fructose (5%)-glycerol (10%) as part of a hospital clinical research program on endoscopic curative treatment for early epithelial neoplastic lesions of the gastrointestinal tract].

    PubMed

    Tall, M L; Salmon, D; Diouf, E; Drai, J; Filali, S; Lépilliez, V; Pioche, M; Laleye, D; Dhelens, C; Ponchon, T; Pivot, C; Pirot, F

    2015-03-01

    As part of a hospital clinical research program on endoscopic curative treatment for early epithelial neoplastic lesions of the gastrointestinal tract, a new hospital sterile and non-pyrogenic preparation of fructose (5%)-glycerol (10%) was realized. Under pharmaceutical legislation, the provision of this hospital preparation involves of aseptic process validation and achieve a stability study. After the aseptic process validation with Mediafill Test, the preparation was made under aseptic conditions associated with a sterilizing filtration according to the good practices preparation. Prepared flexible bags (100mL of solution) were stored for one year in a climatic chamber (25±2°C). To assess stability, the physicochemical controls (fructose concentration, glycerol concentration, hydroxy-methyl-5 furfural [5-HMF] concentration, sodium concentration, pH measure, osmolality and sub-visible particles count) and microbiological (bioburden, bacterial endotoxin and sterility) were performed at regular intervals for one year. Neither significant decrease of fructose concentration, glycerol concentration and sodium concentration nor pH, 5-HMF, osmolality variations out of specifications were observed for one year. The sub-visible particles count, the bacterial endotoxin and sterility were in accordance with the European pharmacopoeia attesting limpidity, apyrogenicity and sterility of this injectable preparation. The hospital preparation was stable over one year at 25±2°C, ensuring safe administration in humans within the framework of this clinical research. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. An Automated Method for High-Definition Transcranial Direct Current Stimulation Modeling*

    PubMed Central

    Huang, Yu; Su, Yuzhuo; Rorden, Christopher; Dmochowski, Jacek; Datta, Abhishek; Parra, Lucas C.

    2014-01-01

    Targeted transcranial stimulation with electric currents requires accurate models of the current flow from scalp electrodes to the human brain. Idiosyncratic anatomy of individual brains and heads leads to significant variability in such current flows across subjects, thus, necessitating accurate individualized head models. Here we report on an automated processing chain that computes current distributions in the head starting from a structural magnetic resonance image (MRI). The main purpose of automating this process is to reduce the substantial effort currently required for manual segmentation, electrode placement, and solving of finite element models. In doing so, several weeks of manual labor were reduced to no more than 4 hours of computation time and minimal user interaction, while current-flow results for the automated method deviated by less than 27.9% from the manual method. Key facilitating factors are the addition of three tissue types (skull, scalp and air) to a state-of-the-art automated segmentation process, morphological processing to correct small but important segmentation errors, and automated placement of small electrodes based on easily reproducible standard electrode configurations. We anticipate that such an automated processing will become an indispensable tool to individualize transcranial direct current stimulation (tDCS) therapy. PMID:23367144

  13. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  14. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  15. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  16. 21 CFR 211.113 - Control of microbiological contamination.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shall include validation of all aseptic and sterilization processes. [43 FR 45077, Sept. 29, 1978, as... Process Controls § 211.113 Control of microbiological contamination. (a) Appropriate written procedures...

  17. A microwave-powered sterilizable interface for aseptic access to bioreactors that are vulnerable to microbial contamination

    NASA Technical Reports Server (NTRS)

    Atwater, J. E.; Michalek, W. F.; Wheeler, R. R. Jr; Dahl, R.; Lunsford, T. D.; Garmon, F. C.; Sauer, R. L.

    2001-01-01

    Novel methods and apparatus that employ the rapid heating characteristics of microwave irradiation to facilitate the aseptic transfer of nutrients, products, and other materials between microbially sensitive systems and the external environment are described. The microwave-sterilizable access port (MSAP) consists of a 600-W magnetron emitting at a frequency of 2.45 GHz, a sterilization chamber with inlet and outlet flow lines, and a specimen transfer interface. Energy is routed to the sterilization chamber via a coaxial transmission line where small quantities of water couple strongly with the incident radiation to produce a superheated vapor phase. The efficiency of energy transfer is enhanced through the use of microwave susceptors within the sterilization chamber. Mating surfaces are thermally sterilized through direct contact with the hot gas. Efficacy has been demonstrated using the thermophile Bacillus stearothermophilus.

  18. Description and Evaluation of Numerical Groundwater Flow Models for the Edwards Aquifer, South-Central Texas

    USGS Publications Warehouse

    Lindgren, Richard J.; Taylor, Charles J.; Houston, Natalie A.

    2009-01-01

    A substantial number of public water system wells in south-central Texas withdraw groundwater from the karstic, highly productive Edwards aquifer. However, the use of numerical groundwater flow models to aid in the delineation of contributing areas for public water system wells in the Edwards aquifer is problematic because of the complex hydrogeologic framework and the presence of conduit-dominated flow paths in the aquifer. The U.S. Geological Survey, in cooperation with the Texas Commission on Environmental Quality, evaluated six published numerical groundwater flow models (all deterministic) that have been developed for the Edwards aquifer San Antonio segment or Barton Springs segment, or both. This report describes the models developed and evaluates each with respect to accessibility and ease of use, range of conditions simulated, accuracy of simulations, agreement with dye-tracer tests, and limitations of the models. These models are (1) GWSIM model of the San Antonio segment, a FORTRAN computer-model code that pre-dates the development of MODFLOW; (2) MODFLOW conduit-flow model of San Antonio and Barton Springs segments; (3) MODFLOW diffuse-flow model of San Antonio and Barton Springs segments; (4) MODFLOW Groundwater Availability Modeling [GAM] model of the Barton Springs segment; (5) MODFLOW recalibrated GAM model of the Barton Springs segment; and (6) MODFLOW-DCM (dual conductivity model) conduit model of the Barton Springs segment. The GWSIM model code is not commercially available, is limited in its application to the San Antonio segment of the Edwards aquifer, and lacks the ability of MODFLOW to easily incorporate newly developed processes and packages to better simulate hydrologic processes. MODFLOW is a widely used and tested code for numerical modeling of groundwater flow, is well documented, and is in the public domain. These attributes make MODFLOW a preferred code with regard to accessibility and ease of use. The MODFLOW conduit-flow model incorporates improvements over previous models by using (1) a user-friendly interface, (2) updated computer codes (MODFLOW-96 and MODFLOW-2000), (3) a finer grid resolution, (4) less-restrictive boundary conditions, (5) an improved discretization of hydraulic conductivity, (6) more accurate estimates of pumping stresses, (7) a long transient simulation period (54 years, 1947-2000), and (8) a refined representation of high-permeability zones or conduits. All of the models except the MODFLOW-DCM conduit model have limitations resulting from the use of Darcy's law to simulate groundwater flow in a karst aquifer system where non-Darcian, turbulent flow might actually dominate. The MODFLOW-DCM conduit model is an improvement in the ability to simulate karst-like flow conditions in conjunction with porous-media-type matrix flow. However, the MODFLOW-DCM conduit model has had limited application and testing and currently (2008) lacks commercially available pre- and post-processors. The MODFLOW conduit-flow and diffuse-flow Edwards aquifer models are limited by the lack of calibration for the northern part of the Barton Springs segment (Travis County) and their reliance on the use of the calibrated hydraulic conductivity and storativity values from the calibrated Barton Springs segment GAM model. The major limitation of the Barton Springs segment GAM and recalibrated GAM models is that they were calibrated to match measured water levels and springflows for a restrictive range of hydrologic conditions, with each model having different hydraulic conductivity and storativity values appropriate to the hydrologic conditions that were simulated. The need for two different sets of hydraulic conductivity and storativity values increases the uncertainty associated with the accuracy of either set of values, illustrates the non-uniqueness of the model solution, and probably most importantly demonstrates the limitations of using a one-layer model to represent the heterogeneous hydrostratigraph

  19. Inferring Aquifer Transmissivity from River Flow Data

    NASA Astrophysics Data System (ADS)

    Trichakis, Ioannis; Pistocchi, Alberto

    2016-04-01

    Daily streamflow data is the measurable result of many different hydrological processes within a basin; therefore, it includes information about all these processes. In this work, recession analysis applied to a pan-European dataset of measured streamflow was used to estimate hydrogeological parameters of the aquifers that contribute to the stream flow. Under the assumption that base-flow in times of no precipitation is mainly due to groundwater, we estimated parameters of European shallow aquifers connected with the stream network, and identified on the basis of the 1:1,500,000 scale Hydrogeological map of Europe. To this end, Master recession curves (MRCs) were constructed based on the RECESS model of the USGS for 1601 stream gauge stations across Europe. The process consists of three stages. Firstly, the model analyses the stream flow time-series. Then, it uses regression to calculate the recession index. Finally, it infers characteristics of the aquifer from the recession index. During time-series analysis, the model identifies those segments, where the number of successive recession days is above a certain threshold. The reason for this pre-processing lies in the necessity for an adequate number of points when performing regression at a later stage. The recession index derives from the semi-logarithmic plot of stream flow over time, and the post processing involves the calculation of geometrical parameters of the watershed through a GIS platform. The program scans the full stream flow dataset of all the stations. For each station, it identifies the segments with continuous recession that exceed a predefined number of days. When the algorithm finds all the segments of a certain station, it analyses them and calculates the best linear fit between time and the logarithm of flow. The algorithm repeats this procedure for the full number of segments, thus it calculates many different values of recession index for each station. After the program has found all the recession segments, it performs calculations to determine the expression for the MRC. Further processing of the MRCs can yield estimates of transmissivity or response time representative of the aquifers upstream of the station. These estimates can be useful for large scale (e.g. continental) groundwater modelling. The above procedure allowed calculating values of transmissivity for a large share of European aquifers, ranging from Tmin = 4.13E-04 m²/d to Tmax = 8.12E+03 m²/d, with an average value Taverage = 9.65E+01 m²/d. These results are in line with the literature, indicating that the procedure may provide realistic results for large-scale groundwater modelling. In this contribution we present the results in the perspective of their application for the parameterization of a pan-European bi-dimensional shallow groundwater flow model.

  20. Variations in aseptic technique and implications for infection control.

    PubMed

    Aziz, Anne Marie

    Healthcare-acquired infections (HAIs) are a serious concern, costing the NHS 1 billion pounds a year and causing 5000 deaths annually despite increased funding. A contributing factor is the variety of aseptic techniques in use in different hospitals and even within a single hospital. These cause problems for healthcare workers as well as increasing the risk of HAI. This article examines a number of traditional approaches to aseptic technique, highlighting their differences and the implications for infection control. It concludes that improvement in aseptic technique could be achieved by implementation of a single unified approach to aseptic technique that can be standardized and audited annually, such as the aseptic non-touch technique (ANTT), which has been recommended for adoption throughout the UK. It ends with suggestions for measures that could be introduced and strengthened to improve aseptic technique, and ultimately reduce the rate of HAI.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doenmez, Halil, E-mail: hdonmez68@yahoo.com; Mavili, Ertugrul, E-mail: ertmavili@yahoo.com; Ikizceli, Tuerkan

    Aseptic meningitis related to hydrogel-coated coils is a known complication, but it is extremely rare after platinum bare coil aseptic meningitis. Here we report the development of aseptic meningitis causing brain stem and cerebellar infarct in a patient with a giant aneurysm treated with bare platinum coils. We conclude that aneurysm size is an important factor affecting the occurrence of aseptic meningitis associated with stroke.

  2. Using magma flow indicators to infer flow dynamics in sills

    NASA Astrophysics Data System (ADS)

    Hoyer, Lauren; Watkeys, Michael K.

    2017-03-01

    Fabrics from Anisotropy of Magnetic Susceptibility (AMS) analyses and Shape Preferred Orientation (SPO) of plagioclase are compared with field structures (such as bridge structures, intrusive steps and magma lobes) formed during magma intrusion in Jurassic sills. This is to constrain magma flow directions in the sills of the Karoo Igneous Province along the KwaZulu-Natal North Coast and to show how accurately certain structures predict a magma flow sense, thus improving the understanding of the Karoo sub-volcanic dynamics. The AMS fabrics are derived from magnetite grains and are well constrained, however the SPO results are commonly steeply inclined, poorly constrained and differ to the AMS fabrics. Both techniques resulted in asymmetrical fabrics. Successful relationships were established between the AMS fabric and the long axes of the magma flow indicators, implying adequate magma flow prediction. However, where numerous sill segments merge, either in the form of magma lobes or bridge structures, the coalescence process creates a new fabric between the segments preserving late-stage magma migration between the merged segments, overprinting the initial magma flow direction.

  3. TECHNIQUES IN ASEPTIC RODENT SURGERY

    PubMed Central

    Hoogstraten-Miller, Shelley L.; Brown, Patricia A.

    2008-01-01

    Performing aseptic survival surgery in rodents can be challenging. This unit describes some basic principles to assist clinicians, researchers, and technicians in becoming proficient in performing aseptic rodent surgery. PMID:18729061

  4. Video-assisted structured teaching to improve aseptic technique during neuraxial block.

    PubMed

    Friedman, Z; Siddiqui, N; Mahmoud, S; Davies, S

    2013-09-01

    Teaching epidural catheter insertion tends to focus on developing manual dexterity rather than improving aseptic technique which usually remains poor despite increasing experience. The aim of this study was to compare epidural aseptic technique performance, by novice operators after a targeted teaching intervention, with operators taught aseptic technique before the intervention was initiated. Starting July 2008, two groups of second-year anaesthesia residents (pre- and post-teaching intervention) performing their 4-month obstetric anaesthesia rotation in a university affiliated centre were videotaped three to four times while performing epidural procedures. Trained blinded independent examiners reviewed the procedures. The primary outcome was a comparison of aseptic technique performance scores (0-30 points) graded on a scale task-specific checklist. A total of 86 sessions by 29 residents were included in the study analysis. The intraclass correlation coefficient for inter-rater reliability for the aseptic technique was 0.90. The median aseptic technique scores for the rotation period were significantly higher in the post-intervention group [27.58, inter-quartile range (IQR) 22.33-29.50 vs 16.56, IQR 13.33-22.00]. Similar results were demonstrated when scores were analysed for low, moderate, and high levels of experience throughout the rotation. Procedure-specific aseptic technique teaching, aided by video assessment and video demonstration, helped significantly improve aseptic practice by novice trainees. Future studies should consider looking at retention over longer periods of time in more senior residents.

  5. Treatment of olecranon bursitis: a systematic review.

    PubMed

    Sayegh, Eli T; Strauch, Robert J

    2014-11-01

    The optimal management of olecranon bursitis is ill-defined. The purposes of this review were to systematically evaluate clinical outcomes for aseptic versus septic bursitis, compare surgical versus nonsurgical management, and examine the roles of corticosteroid injection and aspiration in aseptic bursitis. The English-language literature was searched using PubMed, Cumulative Index to Nursing and Allied Health Literature, Physiotherapy Evidence Database, Allied and Complementary Medicine, and Cochrane Central Register of Controlled Trials. Analyses were performed for clinical resolution and complications after treatment of aseptic and/or septic olecranon bursitis. Twenty-nine studies containing 1278 patients were included. Compared with septic bursitis, aseptic bursitis was associated with a significantly higher overall complication rate (p = 0.0108). Surgical management was less likely to clinically resolve septic or aseptic bursitis (p = 0.0476), and demonstrated higher rates of overall complications (p = 0.0117), persistent drainage (p = 0.0194), and bursal infection (p = 0.0060) than nonsurgical management. Corticosteroid injection for aseptic bursitis was associated with increased overall complications (p = 0.0458) and skin atrophy (p = 0.0261). Aspiration did not increase the risk of bursal infection for aseptic bursitis. Based primarily on level IV evidence, nonsurgical management of olecranon bursitis is significantly more effective and safer than surgical management. The clinical course of aseptic bursitis appears to be more complicated than that of septic bursitis. Corticosteroid injection is associated with significant risks without improving the outcome of aseptic bursitis. Therapeutic IV.

  6. Olecranon bursitis.

    PubMed

    Reilly, Danielle; Kamineni, Srinath

    2016-01-01

    Bursitis is a common medical condition, and of all the bursae in the body, the olecranon bursa is one of the most frequently affected. Bursitis at this location can be acute or chronic in timing and septic or aseptic. Distinguishing between septic and aseptic bursitis can be difficult, and the current literature is not clear on the optimum length or route of antibiotic treatment for septic cases. The current literature was reviewed to clarify these points. The reported data for olecranon bursitis were compiled from the current literature. The most common physical examination findings were tenderness (88% septic, 36% aseptic), erythema/cellulitis (83% septic, 27% aseptic), warmth (84% septic, 56% aseptic), report of trauma or evidence of a skin lesion (50% septic, 25% aseptic), and fever (38% septic, 0% aseptic). General laboratory data ranges were also summarized. Distinguishing between septic and aseptic olecranon bursitis can be difficult because the physical and laboratory data overlap. Evidence for the optimum length and route of antibiotic treatment for septic cases also differs. In this review we have presented the current data of offending bacteria, frequency of key physical examination findings, ranges of reported laboratory data, and treatment practices so that clinicians might have a better guide for treatment. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. LANDSAT-D ground segment operations plan, revision A

    NASA Technical Reports Server (NTRS)

    Evans, B.

    1982-01-01

    The basic concept for the utilization of LANDSAT ground processing resources is described. Only the steady state activities that support normal ground processing are addressed. This ground segment operations plan covers all processing of the multispectral scanner and the processing of thematic mapper through data acquisition and payload correction data generation for the LANDSAT 4 mission. The capabilities embedded in the hardware and software elements are presented from an operations viewpoint. The personnel assignments associated with each functional process and the mechanisms available for controlling the overall data flow are identified.

  8. A Microfabricated Segmented-Involute-Foil Regenerator for Enhancing Reliability and Performance of Stirling Engines

    NASA Technical Reports Server (NTRS)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gadeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2007-01-01

    An actual-size microfabricated regenerator comprised of a stack of 42 disks, 19 mm diameter and 0.25 mm thick, with layers of microscopic, segmented, involute-shaped flow channels was fabricated and tested. The geometry resembles layers of uniformly-spaced segmented-parallel-plates, except the plates are curved. Each disk was made from electro-plated nickel using the LiGA process. This regenerator had feature sizes close to those required for an actual Stirling engine but the overall regenerator dimensions were sized for the NASA/Sunpower oscillating-flow regenerator test rig. Testing in the oscillating-flow test rig showed the regenerator performed extremely well, significantly better than currently used random-fiber material, producing the highest figures of merit ever recorded for any regenerator tested in that rig over its approximately 20 years of use.

  9. PDA survey of quality risk management practices in the pharmaceutical, devices, & biotechnology industries.

    PubMed

    Ahmed, Ruhi; Baseman, Harold; Ferreira, Jorge; Genova, Thomas; Harclerode, William; Hartman, Jeffery; Kim, Samuel; Londeree, Nanette; Long, Michael; Miele, William; Ramjit, Timothy; Raschiatore, Marlene; Tomonto, Charles

    2008-01-01

    In July 2006 the Parenteral Drug Association's Risk Management Task Force for Aseptic Processes, conducted an electronic survey of PDA members to determine current industry practices regarding implementation of Quality Risk Management in their organizations. This electronic survey was open and publicly available via the PDA website and targeted professionals in our industry who are involved in initiating, implementing, or reviewing risk management programs or decisions in their organizations. One hundred twenty-nine members participated and their demographics are presented in the sidebar "Correspondents Profile". Among the major findings are: *The "Aseptic Processing/Filling" operation is the functional area identified as having the greatest need for risk assessment and quality risk management. *The most widely used methodology in industry to identify risk is Failure Mode and Effects Analysis (FMEA). This tool was most widely applied in assessing change control and for adverse event, complaint, or failure investigations. *Despite the fact that personnel training was identified as the strategy most used for controlling/minimizing risk, the largest contributors to sterility failure in operations are still "Personnel". *Most companies still rely on "Manufacturing Controls" to mitigate risk and deemed the utilization of Process Analytical Technology (PAT) least important in this aspect. *A majority of correspondents verified that they did not periodically assess their risk management programs. *A majority of the correspondents desired to see case studies or examples of risk analysis implementation (as applicable to aseptic processing) in future PDA technical reports on risk management.

  10. Aseptic Handling of the MOMA Mass Spectrometer After Dry Heat Microbial Reduction

    NASA Technical Reports Server (NTRS)

    Lalime, Erin

    2017-01-01

    Mars Organic Molecule Analyzer Mass Spectrometer (MOMA-MS) is an instrument in the larger MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. As a life-detection instrument on a Mars landing mission, MOMA-MS has very stringent Planetary Protection (PP) bioburden requirements. Within the MOMA instrument suite, the hardware surfaces of the sample path must be cleaned to a level of 0.03 spore/sq m. To meet this requirement, a process called Dry Heat Microbial Reduction (DHMR) is used to decrease the number of viable spores by 4 orders of magnitude. Before DHMR, the hardware is handled using standard cleanroom practices, while after DHMR, all sample path surfaces must be handled aseptically when exposed. Aseptic handling of the sample path involves a number of strategies and protocols including working only in an aseptic ISO class 5 work space, limiting the amount of time of exposure, using sterile garmenting with sterile gloves, and using sterile tools. Before work begins, the aseptic workspace will be tested for bioburden and particle fallout, and all tools that will contact sample path surfaces must be sterilized. During the exposure activity, sterile garments will be worn, sterile tools will be handled in a 2 person set up so that the operator touches only the sterile tool and not the exterior surfaces of the sterile pouch, and the environment will be monitored with active and passive fallout for bioburden and particle levels. Any breach in the planetary protection cleanliness can necessitate repeating DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

  11. Optimizing and developing a continuous separation system for the wet process separation of aluminum and polyethylene in aseptic composite packaging waste.

    PubMed

    Yan, Dahai; Peng, Zheng; Liu, Yuqiang; Li, Li; Huang, Qifei; Xie, Minghui; Wang, Qi

    2015-01-01

    The consumption of milk in China is increasing as living standards rapidly improve, and huge amounts of aseptic composite milk packaging waste are being generated. Aseptic composite packaging is composed of paper, polyethylene, and aluminum. It is difficult to separate the polyethylene and aluminum, so most of the waste is currently sent to landfill or incinerated with other municipal solid waste, meaning that enormous amounts of resources are wasted. A wet process technique for separating the aluminum and polyethylene from the composite materials after the paper had been removed from the original packaging waste was studied. The separation efficiency achieved using different separation reagents was compared, different separation mechanisms were explored, and the impacts of a range of parameters, such as the reagent concentration, temperature, and liquid-solid ratio, on the separation time and aluminum loss ratio were studied. Methanoic acid was found to be the optimal separation reagent, and the suitable conditions were a reagent concentration of 2-4 mol/L, a temperature of 60-80°C, and a liquid-solid ratio of 30 L/kg. These conditions allowed aluminum and polyethylene to be separated in less than 30 min, with an aluminum loss ratio of less than 3%. A mass balance was produced for the aluminum-polyethylene separation system, and control technique was developed to keep the ion concentrations in the reaction system stable. This allowed a continuous industrial-scale process for separating aluminum and polyethylene to be developed, and a demonstration facility with a capacity of 50t/d was built. The demonstration facility gave polyethylene and aluminum recovery rates of more than 98% and more than 72%, respectively. Separating 1t of aluminum-polyethylene composite packaging material gave a profit of 1769 Yuan, meaning that an effective method for recycling aseptic composite packaging waste was achieved. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. d(-) Lactic Acid-Induced Adhesion of Bovine Neutrophils onto Endothelial Cells Is Dependent on Neutrophils Extracellular Traps Formation and CD11b Expression.

    PubMed

    Alarcón, Pablo; Manosalva, Carolina; Conejeros, Ivan; Carretta, María D; Muñoz-Caro, Tamara; Silva, Liliana M R; Taubert, Anja; Hermosilla, Carlos; Hidalgo, María A; Burgos, Rafael A

    2017-01-01

    Bovine ruminal acidosis is of economic importance as it contributes to reduced milk and meat production. This phenomenon is mainly attributed to an overload of highly fermentable carbohydrate, resulting in increased d(-) lactic acid levels in serum and plasma. Ruminal acidosis correlates with elevated acute phase proteins in blood, along with neutrophil activation and infiltration into various tissues leading to laminitis and aseptic polysynovitis. Previous studies in bovine neutrophils indicated that d(-) lactic acid decreased expression of L-selectin and increased expression of CD11b to concentrations higher than 6 mM, suggesting a potential role in neutrophil adhesion onto endothelia. The two aims of this study were to evaluate whether d(-) lactic acid influenced neutrophil and endothelial adhesion and to trigger neutrophil extracellular trap (NET) production (NETosis) in exposed neutrophils. Exposure of bovine neutrophils to 5 mM d(-) lactic acid elevated NET release compared to unstimulated neutrophil negative controls. Moreover, this NET contains CD11b and histone H 4 citrullinated, the latter was dependent on PAD4 activation, a critical enzyme in DNA decondensation and NETosis. Furthermore, NET formation was dependent on d(-) lactic acid plasma membrane transport through monocarboxylate transporter 1 (MCT1). d(-) lactic acid enhanced neutrophil adhesion onto endothelial sheets as demonstrated by in vitro neutrophil adhesion assays under continuous physiological flow conditions, indicating that cell adhesion was a NET- and a CD11b/ICAM-1-dependent process. Finally, d(-) lactic acid was demonstrated for the first time to trigger NETosis in a PAD4- and MCT1-dependent manner. Thus, d(-) lactic acid-mediated neutrophil activation may contribute to neutrophil-derived pro-inflammatory processes, such as aseptic laminitis and/or polysynovitis in animals suffering acute ruminal acidosis.

  13. Impact of an aseptic procedure for breaking the integrity of the urinary drainage system on the development of catheter-associated urinary tract infections in the intensive care unit.

    PubMed

    Powers, Jan

    2016-12-01

    Catheter associated urinary tract infections (CAUTI) are a common complication in the hospital, especially in intensive care units (ICU). These infections are directly linked to the use of an indwelling urinary catheter. One commonly identified factor related to the development of CAUTI has been thought to be violating the integrity of the closed drainage system. However, a paucity of research exists to support or refute this practice. The primary purpose of this observational study was to assess if there is a relationship between CAUTI incidence and breaking the closed drainage system using an aseptic procedure. A process improvement effort was developed to ensure an aseptic technique was utilised when there was a need to break the integrity of the urinary drainage system. Because this was a new practice and not supported by the Centres for Disease Control (CDC) recommendations, this change in practice was evaluated as an observational study. In an eight month period there were 53 documented breaks in the urinary drainage system. There were 28 total cases of CAUTI overall during this same time period. Only four patients with a system break developed a CAUTI (7.5%). In almost 93% of the patients where aseptic technique was used for breaks in the drainage system, there was no occurrence of CAUTI. A follow-up evaluation was performed after a year of this practice in three adult ICUs. During this three month evaluation period, there were 47 documented cases of breaking this system using aseptic technique. Of the patients who had a documented break in their drainage system, none developed subsequent CAUTIs. One commonly identified factor related to the development of CAUTI has been thought to be violating the integrity of the closed drainage system. However, a paucity of research exists to support or refute this practice. This observational study found that utilising an aseptic technique to break the integrity system did not result in an associated increase in CAUTI. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Effect of pilot-scale aseptic processing on tomato soup quality parameters.

    PubMed

    Colle, Ines J P; Andrys, Anna; Grundelius, Andrea; Lemmens, Lien; Löfgren, Anders; Buggenhout, Sandy Van; Loey, Ann; Hendrickx, Marc Van

    2011-01-01

    Tomatoes are often processed into shelf-stable products. However, the different processing steps might have an impact on the product quality. In this study, a model tomato soup was prepared and the impact of pilot-scale aseptic processing, including heat treatment and high-pressure homogenization, on some selected quality parameters was evaluated. The vitamin C content, the lycopene isomer content, and the lycopene bioaccessibility were considered as health-promoting attributes. As a structural characteristic, the viscosity of the tomato soup was investigated. A tomato soup without oil as well as a tomato soup containing 5% olive oil were evaluated. Thermal processing had a negative effect on the vitamin C content, while lycopene degradation was limited. For both compounds, high-pressure homogenization caused additional losses. High-pressure homogenization also resulted in a higher viscosity that was accompanied by a decrease in lycopene bioaccessibility. The presence of lipids clearly enhanced the lycopene isomerization susceptibility and improved the bioaccessibility. The results obtained in this study are of relevance for product formulation and process design of tomato-based food products. © 2011 Institute of Food Technologists®

  15. Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications

    NASA Astrophysics Data System (ADS)

    Mark, D.; Haeberle, S.; Roth, G.; Von Stetten, F.; Zengerle, R.

    This review summarizes recent developments in microfluidic platform approaches. In contrast to isolated application-specific solutions, a microfluidic platform provides a set of fluidic unit operations, which are designed for easy combination within a well-defined fabrication technology. This allows the implementation of different application-specific (bio-) chemical processes, automated by microfluidic process integration [1]. A brief introduction into technical advances, major market segments and promising applications is followed by a detailed characterization of different microfluidic platforms, comprising a short definition, the functional principle, microfluidic unit operations, application examples as well as strengths and limitations. The microfluidic platforms in focus are lateral flow tests, linear actuated devices, pressure driven laminar flow, microfluidic large scale integration, segmented flow microfluidics, centrifugal microfluidics, electro-kinetics, electrowetting, surface acoustic waves, and systems for massively parallel analysis. The review concludes with the attempt to provide a selection scheme for microfluidic platforms which is based on their characteristics according to key requirements of different applications and market segments. Applied selection criteria comprise portability, costs of instrument and disposable, sample throughput, number of parameters per sample, reagent consumption, precision, diversity of microfluidic unit operations and the flexibility in programming different liquid handling protocols.

  16. 42 CFR 485.725 - Condition of participation: Infection control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... procedures for effective aseptic techniques. The procedures are reviewed annually and revised if necessary to... handled, stored, processed, and transported in such a manner as to prevent the spread of infection. (e...

  17. Revision total knee arthroplasty for septic versus aseptic failure.

    PubMed

    Rajgopal, Ashok; Vasdev, Attique; Gupta, Himanshu; Dahiya, Vivek

    2013-12-01

    To compare the medium-term outcome of revision total knee arthroplasty (TKA) for septic versus aseptic failure. Records of 142 patients who underwent revision TKA by a single senior surgeon for septic (n=65) or aseptic (n=77) failure were reviewed. In the septic group, 67 knees in 42 women and 23 men were included. In the aseptic group, 88 knees in 51 women and 26 men were included. The Knee Society Score was measured. The Kaplan Meier survival curve at months 36, 60, and 95 was plotted, with revision as the end point. The survival rates at each specific time point between the 2 groups were compared using the Z test. The Knee Society Scores improved 18% from 51 to 69 in the septic group and 18% from 52 to 70 in the aseptic group (p=0.72). The range of motion improved 30% from 72 to 102 degrees in the septic group and 39% from 62 to 100 degrees in the aseptic group (p<0.001). Results of the 2 groups were similar in terms of the Knee Society Score, range of motion, and the Kaplan-Meier survivorship.

  18. Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements.

    PubMed

    van Pelt, Roy; Nguyen, Huy; ter Haar Romeny, Bart; Vilanova, Anna

    2012-03-01

    Quantitative analysis of vascular blood flow, acquired by phase-contrast MRI, requires accurate segmentation of the vessel lumen. In clinical practice, 2D-cine velocity-encoded slices are inspected, and the lumen is segmented manually. However, segmentation of time-resolved volumetric blood-flow measurements is a tedious and time-consuming task requiring automation. Automated segmentation of large thoracic arteries, based solely on the 3D-cine phase-contrast MRI (PC-MRI) blood-flow data, was done. An active surface model, which is fast and topologically stable, was used. The active surface model requires an initial surface, approximating the desired segmentation. A method to generate this surface was developed based on a voxel-wise temporal maximum of blood-flow velocities. The active surface model balances forces, based on the surface structure and image features derived from the blood-flow data. The segmentation results were validated using volunteer studies, including time-resolved 3D and 2D blood-flow data. The segmented surface was intersected with a velocity-encoded PC-MRI slice, resulting in a cross-sectional contour of the lumen. These cross-sections were compared to reference contours that were manually delineated on high-resolution 2D-cine slices. The automated approach closely approximates the manual blood-flow segmentations, with error distances on the order of the voxel size. The initial surface provides a close approximation of the desired luminal geometry. This improves the convergence time of the active surface and facilitates parametrization. An active surface approach for vessel lumen segmentation was developed, suitable for quantitative analysis of 3D-cine PC-MRI blood-flow data. As opposed to prior thresholding and level-set approaches, the active surface model is topologically stable. A method to generate an initial approximate surface was developed, and various features that influence the segmentation model were evaluated. The active surface segmentation results were shown to closely approximate manual segmentations.

  19. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    PubMed

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements

    PubMed Central

    Gothesen, Oystein; Lygre, Stein Hakon L; Lorimer, Michelle; Graves, Stephen; Furnes, Ove

    2017-01-01

    Background and purpose — Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods — Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 and 2014, were analyzed with aseptic loosening as primary end-point and all revisions as secondary end-point. We hypothesized that no difference would be found in the rate of revision between rotating-platform and the most used fixed-bearing TKRs, or between keeled and non-keeled tibia. Kaplan–Meier estimates and curves, and Cox regression relative risk estimates adjusted for age, sex, and diagnosis were used for comparison. Results — The rotating-platform TKRs had an increased risk of revision for aseptic loosening compared with the most used fixed-bearing knees, in Norway (RR =6, 95% CI 4–8) and Australia (RR =2.1, 95% CI 1.8–2.5). The risk of aseptic loosening as a reason for revision was highest in Norway compared with Australia (RR =1.7, 95% CI 1.4–2.0). The keeled tibial component had the same risk of aseptic loosening as the non-keeled tibia (Australia). Fixation method and subtypes of the tibial components had no impact on the risk of aseptic loosening in these mobile-bearing knees. Interpretation — The rotating-platform TKRs in this study appeared to have a higher risk of revision for aseptic loosening than the most used fixed-bearing TKRs. PMID:28929828

  1. Evaluating the Effects of Flexible Learning about Aseptic Compounding on First-year Students in a Pharmacy Skills Laboratory.

    PubMed

    Neville, Michael W; Palmer, Russ; Elder, Deborah; Fulford, Michael; Morris, Steve; Sappington, Kellie

    2015-08-25

    To evaluate how flexible learning via online video review affects the ability and confidence of first-year (P1) pharmacy students to accurately compound aseptic preparations. Customary instructions and assignments for aseptic compounding were provided to students, who were given unlimited access to 5 short review videos in addition to customary instruction. Student self-confidence was assessed online, and faculty members evaluated students' aseptic technique at the conclusion of the semester. No significant difference on final assessment scores was observed between those who viewed videos and those who did not. Student self-confidence scores increased significantly from baseline, but were not significantly higher for those who viewed videos than for those who did not. First-year students performed well on final aseptic compounding assessments, and those who viewed videos had a slight advantage. Student self-confidence improved over the semester regardless of whether or not students accessed review videos.

  2. [Dermoid cysts of the posterior cerebral fossa in children revealed by recurrent aseptic meningitis: Report of two cases and a review of the literature].

    PubMed

    Kouadria, R; Derkaoui, M

    2018-03-01

    Dermoid cysts of central nervous system are very rare. The usual clinical presentation is dominated by intracranial hypertension, epilepsy and cranial palsy. The revelation mode could be recurrent aseptic meningitis. The aim of this case report is to consider the dermoid cyst as regards the differential diagnosis in children treated for recurrent aseptic meningitis to avoid misdiagnosis and ice qui a orienté le diagnostic à une méningitnadequate treatment. Two children were admitted in the pediatric department for recurrent aseptic meningitis. The MRI confirmed the presence of a posterior fossa dermoid cyst. Loss of meningitis after microsurgical resection. The diagnosis of dermoid cyst is performed and reconsidered at an early stage in aseptic meningitis in order to establish an adequate therapy, which is surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Added value of experts' knowledge to improve a quantitative microbial exposure assessment model--Application to aseptic-UHT food products.

    PubMed

    Pujol, Laure; Johnson, Nicholas Brian; Magras, Catherine; Albert, Isabelle; Membré, Jeanne-Marie

    2015-10-15

    In a previous study, a quantitative microbial exposure assessment (QMEA) model applied to an aseptic-UHT food process was developed [Pujol, L., Albert, I., Magras, C., Johnson, N. B., Membré, J. M. Probabilistic exposure assessment model to estimate aseptic UHT product failure rate. 2015 International Journal of Food Microbiology. 192, 124-141]. It quantified Sterility Failure Rate (SFR) associated with Bacillus cereus and Geobacillus stearothermophilus per process module (nine modules in total from raw material reception to end-product storage). Previously, the probabilistic model inputs were set by experts (using knowledge and in-house data). However, only the variability dimension was taken into account. The model was then improved using expert elicitation knowledge in two ways. First, the model was refined by adding the uncertainty dimension to the probabilistic inputs, enabling to set a second order Monte Carlo analysis. The eight following inputs, and their impact on SFR, are presented in detail in this present study: D-value for each bacteria of interest (B. cereus and G. stearothermophilus) associated with the inactivation model for the UHT treatment step, i.e., two inputs; log reduction (decimal reduction) number associated with the inactivation model for the packaging sterilization step for each bacterium and each part of the packaging (product container and sealing component), i.e., four inputs; and bacterial spore air load of the aseptic tank and the filler cabinet rooms, i.e., two inputs. Second, the model was improved by leveraging expert knowledge to develop further the existing model. The proportion of bacteria in the product which settled on surface of pipes (between the UHT treatment and the aseptic tank on one hand, and between the aseptic tank and the filler cabinet on the other hand) leading to a possible biofilm formation for each bacterium, was better characterized. It was modeled as a function of the hygienic design level of the aseptic-UHT line: the experts provided the model structure and most of the model parameters values. Mean of SFR was estimated to 10×10(-8) (95% Confidence Interval=[0×10(-8); 350×10(-8)]) and 570×10(-8) (95% CI=[380×10(-8); 820×10(-8)]) for B. cereus and G. stearothermophilus, respectively. These estimations were more accurate (since the confidence interval was provided) than those given by the model with only variability (for which the estimates were 15×10(-8) and 580×10(-8) for B. cereus and G. stearothermophilus, respectively). The updated model outputs were also compared with those obtained when inputs were described by a generic distribution, without specific information related to the case-study. Results showed that using a generic distribution can lead to unrealistic estimations (e.g., 3,181,000 product units contaminated by G. stearothermophilus among 10(8) product units produced) and emphasized the added value of eliciting information from experts from the relevant specialist field knowledge. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Reducing postoperative infections and red breast syndrome in patients with acellular dermal matrix-based breast reconstruction: the relative roles of product sterility and lower body mass index.

    PubMed

    Lewis, Priya; Jewell, James; Mattison, Gennaya; Gupta, Subhas; Kim, Hahns

    2015-05-01

    The use of human acellular dermal matrices (ADM) has become routinely used in implant-based breast surgery. Notwithstanding the many benefits for tissue support, the morbidity associated with its use includes seroma and infection, among other potential complications. Some patients experience a specific complication called red breast syndrome (RBS), which has been linked to ADM use, but its exact etiology remains elusive. In our institution, AlloDerm aseptic regenerative tissue matrix was recently replaced with a ready-to-use sterile version that undergoes terminal sterilization, eliminating the need for rehydration. We want to determine if this change in processing affected complications, including RBS. We conducted a retrospective chart review analyzing patients from January 1, 2011, to June 1, 2013, who underwent breast surgery with human ADM. Patients with aseptic AlloDerm were compared to patients with sterile AlloDerm. Data were analyzed using the Fisher exact test. A total of 167 reconstructed breasts from 105 patients met inclusion criteria: 56% (n=93) with aseptic ADM, 44% (n=74) with sterile ADM. When comparing the two, patients had a decrease in overall necrosis, infection, seroma, and RBS with sterile ADM. However, the rates did not reach statistical significance. For example, the incidence of RBS decreased from 7.5% to 2.7% (P=0.301) and seroma decreased from 8.6% to 2.7% (P=0.188). The infection rate proved to be equivocal at 11.8% with aseptic ADM to 10.8% with sterile ADM (P=1.000). The only statistically significant change was a decrease in the total complication rate from 41.9% to 27.0% (P=0.046). The absolute risk reduction for total complications was 14.9% with a number-needed-to-treat of 7. According to our study, sterile AlloDerm has a clinically decreased incidence of complications compared to aseptic AlloDerm. Whereas RBS decreased, it was interesting to see that it was not eliminated altogether. This suggests that the etiology may be unrelated to ADM processing and warrants further investigation. Overall, the most notable difference was the statistically significant decrease in the total complication rate. Therefore, the change to sterile AlloDerm seems to be beneficial. Further benefit arises from ease of preparation in the operating room.

  5. Innovative food processing technology using ohmic heating and aseptic packaging for meat.

    PubMed

    Ito, Ruri; Fukuoka, Mika; Hamada-Sato, Naoko

    2014-02-01

    Since the Tohoku earthquake, there is much interest in processed foods, which can be stored for long periods at room temperature. Retort heating is one of the main technologies employed for producing it. We developed the innovative food processing technology, which supersede retort, using ohmic heating and aseptic packaging. Electrical heating involves the application of alternating voltage to food. Compared with retort heating, which uses a heat transfer medium, ohmic heating allows for high heating efficiency and rapid heating. In this paper we ohmically heated chicken breast samples and conducted various tests on the heated samples. The measurement results of water content, IMP, and glutamic acid suggest that the quality of the ohmically heated samples was similar or superior to that of the retort-heated samples. Furthermore, based on the monitoring of these samples, it was observed that sample quality did not deteriorate during storage. © 2013. Published by Elsevier Ltd on behalf of The American Meat Science Association. All rights reserved.

  6. Toll-like receptors and aseptic loosening of hip endoprosthesis-a potential to respond against danger signals?

    PubMed

    Lähdeoja, Tuomas; Pajarinen, Jukka; Kouri, Vesa-Petteri; Sillat, Tarvo; Salo, Jari; Konttinen, Yrjö T

    2010-02-01

    Bacterial remnants and subclinical biofilms residing on prosthesis surfaces have been speculated to play a role in hip implant loosening by opsonizing otherwise relatively inert wear particles. The innate immune system recognizes these microbial pathogen-associated molecular patterns (PAMPs) using Toll-like receptors (TLRs). Our objective was to evaluate the possible presence of TLRs in aseptic synovial membrane-like interface tissue. Bacterial culture-negative, aseptic (n = 4) periprosthetic synovial membrane-like tissue was compared to osteoarthritis synovial membrane (n = 5) for the presence of cells positive for all known human functional TLRs, stained using specific antibodies by immunohistochemistry, and evaluated using morphometry. In comparison to osteoarthtritic synovium, the number of TLR-positive cells was found to be increased in the aseptic setting, reflecting the considerable macrophage infiltration to the tissues investigated. Thus aseptic periprosthetic tissue seems to be very reactive to PAMPs. It has been recently recognized that TLR do not only respond to traditional PAMPs, but also to endogenous alarmings or danger signals released from necrotic and activated cells. Alarming-TLR interaction in the periprosthetic tissue might be a novel mechanism of aseptic loosening of endoprosthesis. (c) 2009 Orthopaedic Research Society.

  7. A computational model for simulating solute transport and oxygen consumption along the nephrons

    PubMed Central

    Vallon, Volker; Edwards, Aurélie

    2016-01-01

    The goal of this study was to investigate water and solute transport, with a focus on sodium transport (TNa) and metabolism along individual nephron segments under differing physiological and pathophysiological conditions. To accomplish this goal, we developed a computational model of solute transport and oxygen consumption (QO2) along different nephron populations of a rat kidney. The model represents detailed epithelial and paracellular transport processes along both the superficial and juxtamedullary nephrons, with the loop of Henle of each model nephron extending to differing depths of the inner medulla. We used the model to assess how changes in TNa may alter QO2 in different nephron segments and how shifting the TNa sites alters overall kidney QO2. Under baseline conditions, the model predicted a whole kidney TNa/QO2, which denotes the number of moles of Na+ reabsorbed per moles of O2 consumed, of ∼15, with TNa efficiency predicted to be significantly greater in cortical nephron segments than in medullary segments. The TNa/QO2 ratio was generally similar among the superficial and juxtamedullary nephron segments, except for the proximal tubule, where TNa/QO2 was ∼20% higher in superficial nephrons, due to the larger luminal flow along the juxtamedullary proximal tubules and the resulting higher, flow-induced transcellular transport. Moreover, the model predicted that an increase in single-nephron glomerular filtration rate does not significantly affect TNa/QO2 in the proximal tubules but generally increases TNa/QO2 along downstream segments. The latter result can be attributed to the generally higher luminal [Na+], which raises paracellular TNa. Consequently, vulnerable medullary segments, such as the S3 segment and medullary thick ascending limb, may be relatively protected from flow-induced increases in QO2 under pathophysiological conditions. PMID:27707705

  8. Aseptic meningitis in children: analysis of 506 cases.

    PubMed

    Michos, Athanasios G; Syriopoulou, Vassiliki P; Hadjichristodoulou, Christos; Daikos, George L; Lagona, Evagelia; Douridas, Panagiotis; Mostrou, Glykeria; Theodoridou, Maria

    2007-08-01

    Non-polio human enteroviruses are the leading cause of aseptic meningitis in children. The role of enterovirus PCR for diagnosis and management of aseptic meningitis has not been fully explored. A retrospective study was conducted to determine the epidemiological, clinical, and laboratory characteristics of aseptic meningitis and to evaluate the role of enterovirus PCR for the diagnosis and management of this clinical entity. The medical records of children who had as discharge diagnosis aseptic or viral meningitis were reviewed. A total of 506 children, median age 5 years, were identified. The annual incidence rate was estimated to be 17/100,000 children less than 14 years of age. Most of the cases occurred during summer (38%) and autumn (24%). The dominant clinical symptoms were fever (98%), headache (94%) and vomiting (67%). Neck stiffness was noted in 60%, and irritation in 46% of the patients. The median number of CSF cell count was 201/mm(3) with polymorphonuclear predominance (>50%) in 58.3% of the cases. Enterovirus RNA was detected in CSF in 47 of 96 (48.9%) children tested. Children with positive enterovirus PCR had shorter hospitalization stay as compared to children who had negative PCR or to children who were not tested (P = 0.01). There were no serious complications or deaths. Enteroviruses accounted for approximately one half of cases of aseptic meningitis. PCR may reduce the length of hospitalization and plays important role in the diagnosis and management of children with aseptic meningitis.

  9. Design for disassembly and sustainability assessment to support aircraft end-of-life treatment

    NASA Astrophysics Data System (ADS)

    Savaria, Christian

    Gas turbine engine design is a multidisciplinary and iterative process. Many design iterations are necessary to address the challenges among the disciplines. In the creation of a new engine architecture, the design time is crucial in capturing new business opportunities. At the detail design phase, it was proven very difficult to correct an unsatisfactory design. To overcome this difficulty, the concept of Multi-Disciplinary Optimization (MDO) at the preliminary design phase (Preliminary MDO or PMDO) is used allowing more freedom to perform changes in the design. PMDO also reduces the design time at the preliminary design phase. The concept of PMDO was used was used to create parametric models, and new correlations for high pressure gas turbine housing and shroud segments towards a new design process. First, dedicated parametric models were created because of their reusability and versatility. Their ease of use compared to non-parameterized models allows more design iterations thus reduces set up and design time. Second, geometry correlations were created to minimize the number of parameters used in turbine housing and shroud segment design. Since the turbine housing and the shroud segment geometries are required in tip clearance analyses, care was taken as to not oversimplify the parametric formulation. In addition, a user interface was developed to interact with the parametric models and improve the design time. Third, the cooling flow predictions require many engine parameters (i.e. geometric and performance parameters and air properties) and a reference shroud segments. A second correlation study was conducted to minimize the number of engine parameters required in the cooling flow predictions and to facilitate the selection of a reference shroud segment. Finally, the parametric models, the geometry correlations, and the user interface resulted in a time saving of 50% and an increase in accuracy of 56% in the new design system compared to the existing design system. Also, regarding the cooling flow correlations, the number of engine parameters was reduced by a factor of 6 to create a simplified prediction model and hence a faster shroud segment selection process. None

  10. Iterative co-creation for improved hand hygiene and aseptic techniques in the operating room: experiences from the safe hands study.

    PubMed

    Erichsen Andersson, Annette; Frödin, Maria; Dellenborg, Lisen; Wallin, Lars; Hök, Jesper; Gillespie, Brigid M; Wikström, Ewa

    2018-01-04

    Hand hygiene and aseptic techniques are essential preventives in combating hospital-acquired infections. However, implementation of these strategies in the operating room remains suboptimal. There is a paucity of intervention studies providing detailed information on effective methods for change. This study aimed to evaluate the process of implementing a theory-driven knowledge translation program for improved use of hand hygiene and aseptic techniques in the operating room. The study was set in an operating department of a university hospital. The intervention was underpinned by theories on organizational learning, culture and person centeredness. Qualitative process data were collected via participant observations and analyzed using a thematic approach. Doubts that hand-hygiene practices are effective in preventing hospital acquired infections, strong boundaries and distrust between professional groups and a lack of psychological safety were identified as barriers towards change. Facilitated interprofessional dialogue and learning in "safe spaces" worked as mechanisms for motivation and engagement. Allowing for the free expression of different opinions, doubts and viewing resistance as a natural part of any change was effective in engaging all professional categories in co-creation of clinical relevant solutions to improve hand hygiene. Enabling nurses and physicians to think and talk differently about hospital acquired infections and hand hygiene requires a shift from the concept of one-way directed compliance towards change and learning as the result of a participatory and meaning-making process. The present study is a part of the Safe Hands project, and is registered with ClinicalTrials.gov (ID: NCT02983136 ). Date of registration 2016/11/28, retrospectively registered.

  11. Volume Segmentation and Ghost Particles

    NASA Astrophysics Data System (ADS)

    Ziskin, Isaac; Adrian, Ronald

    2011-11-01

    Volume Segmentation Tomographic PIV (VS-TPIV) is a type of tomographic PIV in which images of particles in a relatively thick volume are segmented into images on a set of much thinner volumes that may be approximated as planes, as in 2D planar PIV. The planes of images can be analysed by standard mono-PIV, and the volume of flow vectors can be recreated by assembling the planes of vectors. The interrogation process is similar to a Holographic PIV analysis, except that the planes of image data are extracted from two-dimensional camera images of the volume of particles instead of three-dimensional holographic images. Like the tomographic PIV method using the MART algorithm, Volume Segmentation requires at least two cameras and works best with three or four. Unlike the MART method, Volume Segmentation does not require reconstruction of individual particle images one pixel at a time and it does not require an iterative process, so it operates much faster. As in all tomographic reconstruction strategies, ambiguities known as ghost particles are produced in the segmentation process. The effect of these ghost particles on the PIV measurement is discussed. This research was supported by Contract 79419-001-09, Los Alamos National Laboratory.

  12. Evaluating the Effects of Flexible Learning about Aseptic Compounding on First-year Students in a Pharmacy Skills Laboratory

    PubMed Central

    Palmer, Russ; Elder, Deborah; Fulford, Michael; Morris, Steve; Sappington, Kellie

    2015-01-01

    Objective. To evaluate how flexible learning via online video review affects the ability and confidence of first-year (P1) pharmacy students to accurately compound aseptic preparations. Design. Customary instructions and assignments for aseptic compounding were provided to students, who were given unlimited access to 5 short review videos in addition to customary instruction. Student self-confidence was assessed online, and faculty members evaluated students’ aseptic technique at the conclusion of the semester. Assessment. No significant difference on final assessment scores was observed between those who viewed videos and those who did not. Student self-confidence scores increased significantly from baseline, but were not significantly higher for those who viewed videos than for those who did not. Conclusion. First-year students performed well on final aseptic compounding assessments, and those who viewed videos had a slight advantage. Student self-confidence improved over the semester regardless of whether or not students accessed review videos. PMID:26430278

  13. Simulation research on the process of large scale ship plane segmentation intelligent workshop

    NASA Astrophysics Data System (ADS)

    Xu, Peng; Liao, Liangchuang; Zhou, Chao; Xue, Rui; Fu, Wei

    2017-04-01

    Large scale ship plane segmentation intelligent workshop is a new thing, and there is no research work in related fields at home and abroad. The mode of production should be transformed by the existing industry 2.0 or part of industry 3.0, also transformed from "human brain analysis and judgment + machine manufacturing" to "machine analysis and judgment + machine manufacturing". In this transforming process, there are a great deal of tasks need to be determined on the aspects of management and technology, such as workshop structure evolution, development of intelligent equipment and changes in business model. Along with them is the reformation of the whole workshop. Process simulation in this project would verify general layout and process flow of large scale ship plane section intelligent workshop, also would analyze intelligent workshop working efficiency, which is significant to the next step of the transformation of plane segmentation intelligent workshop.

  14. Progressive epicardial coronary blood flow reduction fails to produce ST-segment depression at normal heart rates.

    PubMed

    de Chantal, Marilyn; Diodati, Jean G; Nasmith, James B; Amyot, Robert; LeBlanc, A Robert; Schampaert, Erick; Pharand, Chantal

    2006-12-01

    ST-segment depression is commonly seen in patients with acute coronary syndromes. Most authors have attributed it to transient reductions in coronary blood flow due to nonocclusive thrombus formation on a disrupted atherosclerotic plaque and dynamic focal vasospasm at the site of coronary artery stenosis. However, ST-segment depression was never reproduced in classic animal models of coronary stenosis without the presence of tachycardia. We hypothesized that ST-segment depression occurring during acute coronary syndromes is not entirely explained by changes in epicardial coronary artery resistance and thus evaluated the effect of a slow, progressive epicardial coronary artery occlusion on the ECG and regional myocardial blood flow in anesthetized pigs. Slow, progressive occlusion over 72 min (SD 27) of the left anterior descending coronary artery in 20 anesthetized pigs led to a 90% decrease in coronary blood flow and the development of ST-segment elevation associated with homogeneous and transmural myocardial blood flow reductions, confirmed by microspheres and myocardial contrast echocardiography. ST-segment depression was not observed in any ECG lead before the development of ST-segment elevation. At normal heart rates, progressive epicardial stenosis of a coronary artery results in myocardial ischemia associated with homogeneous, transmural reduction in regional myocardial blood flow and ST-segment elevation, without preceding ST-segment depression. Thus, in coronary syndromes with ST-segment depression and predominant subendocardial ischemia, factors other than mere increases in epicardial coronary resistance must be invoked to explain the heterogeneous parietal distribution of flow and associated ECG changes.

  15. Particle Disease: A Current Review of the Biological Mechanisms in Periprosthetic Osteolysis After Hip Arthroplasty

    PubMed Central

    Sukur, Erhan; Akman, Yunus Emre; Ozturkmen, Yusuf; Kucukdurmaz, Fatih

    2016-01-01

    Background: Inflammatory responses to wear debris cause osteolysis that leads to aseptic prosthesis loosening and hip arthroplasty failure. Although osteolysis is usually associated with aseptic loosening, it is rarely seen around stable implants. Aseptic implant loosening is a simple radiologic phenomenon, but a complex immunological process. Particulate debris produced by implants most commonly causes osteolysis, and this is called particle-associated periprosthetic osteolysis (PPO). Objective: The objective of this review is to outline the features of particle-associated periprosthetic osteolysis to allow the physician to recognise this condition and commence early treatment, thereby optimizing patient outcome. Methods: A thorough literature search was performed using available databases, including Pubmed, to cover important research published covering particle-associated PPO. Results: Although osteolysis causes bone resorption, clinical, animal, and in vitro studies of particle bioreactivity suggest that particle-associated PPO represents the culmination of several biological reactions of many cell types, rather than being caused solely by the osteoclasts. The biological activity is highly dependent on the characteristics and quantity of the wear particles. Conclusion: Despite advances in total hip arthroplasty (THA), particle-associated PPO and aseptic loosening continue to be major factors that affect prosthetic joint longevity. Biomarkers could be exploited as easy and objective diagnostic and prognostic targets that would enable testing for osteolysis after THA. Further research is needed to identify new biomarkers in PPO. A comprehensive understanding of the underlying biological mechanisms is crucial for developing new therapeutic interventions to reverse or suppress biological responses to wear particles. PMID:27499822

  16. The risk of aseptic meningitis associated with the Leningrad-Zagreb mumps vaccine strain following mass vaccination with measles-mumps-rubella vaccine, Rio Grande do Sul, Brazil, 1997.

    PubMed

    da Silveira, Claudio Marcos; Kmetzsch, Claudete Iris; Mohrdieck, Renate; Sperb, Alethea Fagundes; Prevots, D Rebecca

    2002-10-01

    Few data are available on the risk of aseptic meningitis following vaccination with the Leningrad-Zagreb (L-Z) strain of mumps vaccine. In 1997 the mumps vaccine was introduced into the state of Rio Grande do Sul in Brazil through mass vaccination with mumps-measles-rubella (MMR), targeting children aged 1-11 years. Five municipalities used exclusively MMR vaccine containing the L-Z strain of mumps. An outbreak of aseptic meningitis was observed shortly after the mass campaign. To estimate the risk of aseptic meningitis associated with this strain, we analysed vaccination and meningitis case surveillance data from the selected municipalities. A case of vaccine-associated aseptic meningitis was defined as one with a pleocytosis of 10-1,500 leukocytes/ml and occurring within 15-35 days after vaccine receipt. We estimated a risk of 2.9 cases per 10,000 doses of L-Z administered, equivalent to 1 case per 3,390 doses administered. The overall risk of aseptic meningitis following the campaign was increased 12.2-fold (95% CI: 6.0-24.7) compared with the same period in 1995-1996. Following the mass campaign, the incidence of mumps declined 93% during 1998-2000. Vaccination with the L-Z strain of mumps vaccine as part of a mass campaign was associated with a significantly increased risk of aseptic meningitis. Decisions about type of mumps vaccine and mumps vaccination strategies must consider vaccine safety issues in addition to other criteria.

  17. Diabetes Mellitus and Hyperglycemia and the Risk of Aseptic Loosening in Total Joint Arthroplasty.

    PubMed

    Maradit Kremers, Hilal; Schleck, Cathy D; Lewallen, Eric A; Larson, Dirk R; Van Wijnen, Andre J; Lewallen, David G

    2017-09-01

    It is unknown to what extent diabetes mellitus modifies the long-term risk of aseptic loosening in total hip arthroplasty (THA) and total knee arthroplasty (TKA). We examined the association between diabetes mellitus, perioperative hyperglycemia, and the likelihood of revisions for aseptic loosening. We studied 16,085 primary THA and TKA procedures performed at a large tertiary care hospital between 2002 and 2009. All blood glucose values around the time of surgery (within 1 week) were retrieved. Subsequent revision surgeries and the reasons for revision were ascertained through the institutional joint registry. Multivariate Cox models were used to estimate the hazard ratios (HRs) and 95% confidence intervals (CIs) for aseptic loosening associated with diabetes mellitus and hyperglycemia adjusting for age, gender, body mass index, and surgery type. A total of 2911 (18%) surgeries had a diagnosis of diabetes mellitus at the time of surgery. Glucose testing was performed at least once in 7055 (44%) procedures within ±1 week of surgery. Although diabetic patients did not experience a higher risk of revision for aseptic loosening (HR, 0.87; 95% CI, 0.55-1.38), higher preoperative glucose values on the day before surgery were significantly associated with both the overall risk of revisions (HR, 2.80; 95% CI, 1.00-7.85) and revisions for aseptic loosening (HR, 4.95; 95% CI, 1.26-19.54). High preoperative hyperglycemia is a potential risk factor for aseptic loosening in THA and TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Cryopreservation of Salix sp. dormant winter buds

    USDA-ARS?s Scientific Manuscript database

    In cryopreservation, using dormant winter buds (DB) as source plant materials is economically advantageous over tissue culture options (TC). Processing DB does not require aseptic conditions and elaborate cryopreservation procedures. However, the DB approach is only feasible for cryopreserving a sel...

  19. Comparative Analysis of Direct Hospital Care Costs between Aseptic and Two-Stage Septic Knee Revision

    PubMed Central

    Kasch, Richard; Merk, Sebastian; Assmann, Grit; Lahm, Andreas; Napp, Matthias; Merk, Harry; Flessa, Steffen

    2017-01-01

    Background The most common intermediate and long-term complications of total knee arthroplasty (TKA) include aseptic and septic failure of prosthetic joints. These complications cause suffering, and their management is expensive. In the future the number of revision TKA will increase, which involves a greater financial burden. Little concrete data about direct costs for aseptic and two-stage septic knee revisions with an in depth-analysis of septic explantation and implantation is available. Questions/Purposes A retrospective consecutive analysis of the major partial costs involved in revision TKA for aseptic and septic failure was undertaken to compare 1) demographic and clinical characteristics, and 2) variable direct costs (from a hospital department’s perspective) between patients who underwent single-stage aseptic and two-stage septic revision of TKA in a hospital providing maximum care. We separately analyze the explantation and implantation procedures in septic revision cases and identify the major cost drivers of knee revision operations. Methods A total of 106 consecutive patients (71 aseptic and 35 septic) was included. All direct costs of diagnosis, surgery, and treatment from the hospital department’s perspective were calculated as real purchase prices. Personnel involvement was calculated in units of minutes. Results Aseptic versus septic revisions differed significantly in terms of length of hospital stay (15.2 vs. 39.9 days), number of reported secondary diagnoses (6.3 vs. 9.8) and incision-suture time (108.3 min vs. 193.2 min). The management of septic revision TKA was significantly more expensive than that of aseptic failure ($12,223.79 vs. $6,749.43) (p <.001). On the level of the separate hospitalizations the mean direct costs of explantation stage ($4,540.46) were lower than aseptic revision TKA ($6,749.43) which were again lower than those of the septic implantation stage ($7,683.33). All mean costs of stays were not comparable as they differ significantly (p <.001). Major cost drivers were the cost of the implant and general staff. The septic implantation part was on average $3,142.87 more expensive than septic explantations (p <.001). Conclusions Our study for the first time provides a detailed analysis of the major direct case costs of aseptic and septic revision TKA from the hospital-department’s perspective which is the basis for long-term orientated decision making. In the future, our cost analysis has to be interpreted in relation to reimbursement estimates. This is important to check whether revision TKA lead to a financial loss for the operating department. PMID:28107366

  20. Risk factors for lower urinary tract infection and bacterial stent colonization in patients with a double J ureteral stent.

    PubMed

    Akay, Ali Ferruh; Aflay, Uğur; Gedik, Abdullah; Sahin, Hayrettin; Bircan, Mehmet Kamuran

    2007-01-01

    We investigated the potential risk factors for lower urinary tract infection and bacterial stent colonization in patients with double-J stents. A total of 195 double-J stents from 190 patients (95 men and 95 women, mean age 40.22 years) were examined. In all patients, prophylactic antimicrobial therapy was administered at the time of stenting. The stents and urine samples were removed aseptically and the proximal and distal tip segments of the stents were obtained. Three culture specimens were obtained from each stent segment and urine sample. Chi-square tests, odds ratio, and relative risk were used for the statistical analysis. Bacterial colonies were found in 24% (47 of 190) of the urine samples, 31% (61 of 195) of the proximal stent segments, and 34% (67 of 195) of the distal stent segments. Of the pathogens identified, Escherichia coli (34 of 47) was the most common. Diabetes mellitus (P < 0.01), chronic renal failure (P < 0.001), and pregnancy (P < 0.01) were found to be risk factors for lower urinary tract infection in patients with stents. An increased stent colonization rate was associated with implantation time, age, and female sex, but these were not statistically significant for lower urinary tract infection Diabetes mellitus, chronic renal failure, and pregnancy are associated with a higher risk of lower urinary tract infection. Therefore, patients in these categories should be monitored carefully for infectious complications.

  1. Recent developments in processing systems for cell and tissue cultures toward therapeutic application.

    PubMed

    Kino-oka, Masahiro; Taya, Masahito

    2009-10-01

    Innovative techniques of cell and tissue processing, based on tissue engineering, have been developed for therapeutic applications. Cell expansion and tissue reconstruction through ex vivo cultures are core processes used to produce engineered tissues with sufficient structural integrity and functionality. In manufacturing, strict management against contamination and human error is compelled due to direct use of un-sterilable products and the laboriousness of culture operations, respectively. Therefore, the development of processing systems for cell and tissue cultures is one of the critical issues for ensuring a stable process and quality of therapeutic products. However, the siting criterion of culture systems to date has not been made clear. This review article classifies some of the known processing systems into 'sealed-chamber' and 'sealed-vessel' culture systems based on the difference in their aseptic spaces, and describes the potential advantages of these systems and current states of culture systems, especially those established by Japanese companies. Moreover, on the basis of the guidelines for isolator systems used in aseptic processing for healthcare products, which are issued by the International Organization for Standardization, the siting criterion of the processing systems for cells and tissue cultures is discussed in perspective of manufacturing therapeutic products in consideration of the regulations according to the Good Manufacturing Practice.

  2. Judging The Efficacy of Anthrax Fumigations

    DTIC Science & Technology

    2003-11-20

    FUMIGATIONS IN RESPONSE TO 2001 ANTHRAX ATTACKS Most fumigations modeled after biomedical sterilization processes, with established ranges for process...exposure to VHP All BIs recovered aseptically negative for growth of B. stearothermophilus Positive control BIs (5% of BIs) demonstrate growth Negative...of 10 zones was re-fumigated; second fumigation met all requirements HISTORICAL CRITERIA FOR SUCCESSFUL TREATMENT Biomedical sterilizations – FDA

  3. Feasibility of Applying Ohmic Heating and Split-Phase Aseptic Processing for Ration Entree Preservation

    DTIC Science & Technology

    1994-08-01

    study demonstrated that either of these reduced- temperature sterilization processes will produce an acceptable product that is an alternative to thermal...and uniform heating of liquids and solids simultaneously, even of large particles, up to sterilization temperatures . Uniform heating means shorter...potential cost reduction by substitution of continuous processing of a high- temperature /short-time ( HTST ) nature for traditional batch retort

  4. A Novel Gradient Vector Flow Snake Model Based on Convex Function for Infrared Image Segmentation

    PubMed Central

    Zhang, Rui; Zhu, Shiping; Zhou, Qin

    2016-01-01

    Infrared image segmentation is a challenging topic because infrared images are characterized by high noise, low contrast, and weak edges. Active contour models, especially gradient vector flow, have several advantages in terms of infrared image segmentation. However, the GVF (Gradient Vector Flow) model also has some drawbacks including a dilemma between noise smoothing and weak edge protection, which decrease the effect of infrared image segmentation significantly. In order to solve this problem, we propose a novel generalized gradient vector flow snakes model combining GGVF (Generic Gradient Vector Flow) and NBGVF (Normally Biased Gradient Vector Flow) models. We also adopt a new type of coefficients setting in the form of convex function to improve the ability of protecting weak edges while smoothing noises. Experimental results and comparisons against other methods indicate that our proposed snakes model owns better ability in terms of infrared image segmentation than other snakes models. PMID:27775660

  5. Continuous-flow synthesis of functionalized phenols by aerobic oxidation of Grignard reagents.

    PubMed

    He, Zhi; Jamison, Timothy F

    2014-03-24

    Phenols are important compounds in chemical industry. An economical and green approach to phenol preparation by the direct oxidation of aryl Grignard reagents using compressed air in continuous gas-liquid segmented flow systems is described. The process tolerates a broad range of functional groups, including oxidation-sensitive functionalities such as alkenes, amines, and thioethers. By integrating a benzyne-mediated in-line generation of arylmagnesium intermediates with the aerobic oxidation, a facile three-step, one-flow process, capable of preparing 2-functionalized phenols in a modular fashion, is established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Computer simulation of storm runoff for three watersheds in Albuquerque, New Mexico

    USGS Publications Warehouse

    Knutilla, R.L.; Veenhuis, J.E.

    1994-01-01

    Rainfall-runoff data from three watersheds were selected for calibration and verification of the U.S. Geological Survey's Distributed Routing Rainfall-Runoff Model. The watersheds chosen are residentially developed. The conceptually based model uses an optimization process that adjusts selected parameters to achieve the best fit between measured and simulated runoff volumes and peak discharges. Three of these optimization parameters represent soil-moisture conditions, three represent infiltration, and one accounts for effective impervious area. Each watershed modeled was divided into overland-flow segments and channel segments. The overland-flow segments were further subdivided to reflect pervious and impervious areas. Each overland-flow and channel segment was assigned representative values of area, slope, percentage of imperviousness, and roughness coefficients. Rainfall-runoff data for each watershed were separated into two sets for use in calibration and verification. For model calibration, seven input parameters were optimized to attain a best fit of the data. For model verification, parameter values were set using values from model calibration. The standard error of estimate for calibration of runoff volumes ranged from 19 to 34 percent, and for peak discharge calibration ranged from 27 to 44 percent. The standard error of estimate for verification of runoff volumes ranged from 26 to 31 percent, and for peak discharge verification ranged from 31 to 43 percent.

  7. ASRM test report: Autoclave cure process development

    NASA Technical Reports Server (NTRS)

    Nachbar, D. L.; Mitchell, Suzanne

    1992-01-01

    ASRM insulated segments will be autoclave cured following insulation pre-form installation and strip wind operations. Following competitive bidding, Aerojet ASRM Division (AAD) Purchase Order 100142 was awarded to American Fuel Cell and Coated Fabrics Company, Inc. (Amfuel), Magnolia, AR, for subcontracted insulation autoclave cure process development. Autoclave cure process development test requirements were included in Task 3 of TM05514, Manufacturing Process Development Specification for Integrated Insulation Characterization and Stripwind Process Development. The test objective was to establish autoclave cure process parameters for ASRM insulated segments. Six tasks were completed to: (1) evaluate cure parameters that control acceptable vulcanization of ASRM Kevlar-filled EPDM insulation material; (2) identify first and second order impact parameters on the autoclave cure process; and (3) evaluate insulation material flow-out characteristics to support pre-form configuration design.

  8. Unusually severe varicella zoster (VZV) virus viral (aseptic) meningitis in an unimmunized, immunocompetent host with chickenpox.

    PubMed

    Cunha, Burke A; Warren-Favorito, Heather; Mickail, Nardeen

    2011-01-01

    Chickenpox is caused by the varicella zoster virus (VZV) and may be more severe in adults than in children. Central nervous system (CNS) manifestations of chickenpox and VZV are uncommon, for example, encephalitis and cerebellar ataxis. Viral (aseptic) meningitis is a rare CNS complication of VZV. The cerebrospinal fluid (CSF) profile in VZV viral (aseptic) meningitis is indistinguishable from other causes of viral meningitis. The clue to most of the diagnoses of VZV aseptic meningitis is based on the temporal relationship between antecedent or concomitant chickenpox. Chickenpox is a clinical diagnosis based on the appearance and distribution of the rash. The rash of chickenpox is vesicular/pruritic and typically appears in crops over 3 successive days. VZV vesicles are fragile, superficial, and surrounded by a erythematous halo. Common nonspecific laboratory findings in chickenpox include leukopenia, thrombocytopenia, and elevated serum transaminases (serum glutamate-oxaloacetate transaminase/serum glutamate-pyruvate transaminase). The erythrocyte sedimentation rate (ESR) is not highly elevated in chickenpox. In VZV aseptic meningitis, the CSF shows a lymphocytic pleocytosis with normal protein, glucose, and lactic acid levels. CSF red blood cells are not a feature of VZV meningitis. We present the case of a healthy unimmunized adult who was hospitalized with chickenpox complicated by VZV aseptic meningitis with an unusually severe headache and nuchal rigidity that occurred during hospitalization. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Increased incidence of patella baja after total knee arthroplasty revision for infection.

    PubMed

    Chen, Antonia F; Tetreault, Matthew W; Levicoff, Eric A; Fedorka, Catherine J; Rothenberg, Adam C; Klatt, Brian A

    2014-12-01

    The incidence of patella baja in total knee arthroplasty (TKA) revisions for aseptic and septic causes is not well defined. We retrospectively reviewed 101 mobile-bearing TKA revisions performed between 2003 and 2009. Aseptic (n=67) and septic (n=34) revisions were compared for patella baja. A nonarticulating spacer was used as the initial treatment for infected cases. The Insall-Salvati ratio was radiographically measured before surgery (preexplant for septic revisions) and at latest follow-up (postreplant for septic revisions). Mean (SD) Insall-Salvati ratio did not differ between groups before surgery, 1.00 (0.25) for aseptic and 0.96 (0.22) for septic, but differed significantly after surgery, 0.99 (0.23) for aseptic and 0.77 (0.24) for septic. After correcting for preoperative patellar height, there was a statistically significant postoperative difference between aseptic cases, 1.09 (0.19), and septic cases, 0.82 (0.21). There was also a significant difference in mean (SD) postoperative range of motion (ROM) between aseptic cases, 108.0° (20.7°), and septic cases, 92.2° (34.6°), and decreased ROM between cases with patella baja, 95.1° (31.6°) and cases without patella baja, 106.8° (23.6°). TKA revisions done for septic causes using a nonarticulating spacer resulted in a higher incidence of patella baja and decreased ROM.

  10. The Effect of Sterile Acellular Dermal Matrix Use on Complication Rates in Implant-Based Immediate Breast Reconstructions

    PubMed Central

    Park, Youngsoo; Choi, Kyoung Wook; Chung, Kyu-Jin; Kim, Tae Gon; Kim, Yong-Ha

    2016-01-01

    Background The use of acellular dermal matrix (ADM) in implant-based immediate breast reconstruction has been increasing. The current ADMs available for breast reconstruction are offered as aseptic or sterile. No published studies have compared aseptic and sterile ADM in implant-based immediate breast reconstruction. The authors performed a retrospective study to evaluate the outcomes of aseptic versus sterile ADM in implant-based immediate breast reconstruction. Methods Implant-based immediate breast reconstructions with ADM conducted between April 2013 and January 2016 were included. The patients were divided into 2 groups: the aseptic ADM (AlloDerm) group and the sterile ADM (MegaDerm) group. Archived records were reviewed for demographic data and postoperative complication types and frequencies. The complications included were infection, flap necrosis, capsular contracture, seroma, hematoma, and explantation for any cause. Results Twenty patients were reconstructed with aseptic ADM, and 68 patients with sterile ADM. Rates of infection (15.0% vs. 10.3%), flap necrosis (5.0% vs. 7.4%), capsular contracture (20.0% vs. 14.7%), seroma (10.0% vs. 14.7%), hematoma (0% vs. 1.5%), and explantation (10.0% vs. 8.8%) were not significantly different in the 2 groups. Conclusions Sterile ADM did not provide better results regarding infectious complications than aseptic ADM in implant-based immediate breast reconstruction. PMID:27896182

  11. Molecular Identification of Bacteria from Aseptically Loose Implants

    PubMed Central

    Kobayashi, Naomi; Procop, Gary W.; Krebs, Viktor; Kobayashi, Hideo

    2008-01-01

    Polymerase chain reaction (PCR) assays have been used to detect bacteria adherent to failed orthopaedic implants, but some PCR assays have had problems with probable false-positive results. We used a combination of a Staphylococcus species-specific PCR and a universal PCR followed by DNA sequencing to identify bacteria on implants retrieved from 52 patients (92 implants) at revision arthroplasty. We addressed two questions in this study: (1) Is this method able to show the existence of bacterial DNA on presumed aseptic loosed implants?; and (2) What proportion of presumed aseptic or culture-negative implants was positive for bacterial DNA by PCR? Fourteen implants (15%) were believed infected, whereas 74 implants (85%) were believed aseptic. Each implant was sonicated and the resulting solution was submitted for dual real-time PCR assay and culture. All implants believed aseptically loose were culture-negative, but nine of the 74 (12%) had bacterial DNA by PCR; two (2.7%) were PCR-positive and also showed histologic findings suggestive of infection. Uniquely developed PCR and bacterial sequencing assays showed bacterial DNA on 12% of implants removed for presumed aseptic loosening. Additional studies are needed to determine the clinical importance of bacterial DNA detected by PCR but not by conventional culture. Level of Evidence: Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18438724

  12. Isolation and molecular identification of echovirus 13 isolated from patients of aseptic meningitis in Korea, 2002.

    PubMed

    Cheon, Doo-Sung; Lee, Jiwon; Lee, Kangbum; Lee, Sunhwa; Park, Kwisung; Ahn, Jungbae; Jee, Youngmee; Yoon, Jaedeuk; Cho, Haewol

    2004-07-01

    During 2002, several epidemics of aseptic meningitis were attributed to echovirus 13 in Korea. The causative agents of these outbreaks were isolated and identified using rhabdosarcoma cells, HEp-2 and Buffalo green monkey kidney cells, and a neutralization test using monospecific antiserum. Fifty-four echovirus 13 isolates were isolated from patients with aseptic meningitis in the provinces, Seoul, Kyonggi, Gwangju, Jeonju, Busan, and Ulsan. Symptoms associated with aseptic meningitis infection in patients included the occurrence of headaches and mild fever. Molecular characterization of echovirus 13 samples was achieved by sequence and phylogenetic analyses on partial VP1 sequences from 20 Korean isolates and 10 foreign isolates listed in Genbank. Minor variation was observed among the Korean isolates, which formed a unique cluster with isolates of German and Japanese origin. The marked similarities between isolates could be attributed to a relatively recent arrival of the virus in Korea. This is the first such investigation of aseptic meningitis caused by echovirus 13 on the Korean peninsula. Copyright 2004 Wiley-Liss, Inc.

  13. Echovirus 15 and autumn meningitis outbreak among children, Patras, Greece, 2005.

    PubMed

    Frantzidou, Filanthi; Dumaidi, Kamal; Spiliopoulou, Adamantia; Antoniadis, Antonis; Papa, Anna

    2007-09-01

    Enteroviruses are the most common cause of aseptic meningitis, presenting in epidemic or endemic form. To determine the causative agent of an aseptic meningitis outbreak in autumn, 2005 in Patras, Greece. Cerebrospinal fluid (CSF) samples taken during May 2005-February 2006 from children admitted to the Children Hospital of Patras with signs of aseptic meningitis were tested for the presence of enteroviral RNA. Typing was performed by nucleotide analysis. Enteroviruses were detected in 11 (57.9%) of 19 tested CSF samples. In a 12-day period (27 October-7 November 2005) five aseptic meningitis cases were observed. Echovirus 15 was detected in all five cases, and differed from the prototype strain by 27.6%. Enteroviruses before and after this cluster of cases were of different serotypes (Echovirus 9, Echovirus 6). All patients with Echovirus 15 infection were male with a mean age of 7.7 years (2 months-13 years), all recovered successfully. This is the first report of a cluster of aseptic meningitis cases caused by Echovirus 15. The causative agent was a new variant of Echovirus 15.

  14. Unraveling the Processing Parameters in Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Schneider, Judy; Nunes, Arthur C., Jr.

    2005-01-01

    In friction stir welding (FSW), a rotating threaded pin tool is translated along a weld seam, literally stirring the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path or paths is required. In this study, various markers are used to trace the flow paths of the metal. X-ray radiographs record the segmentation and position of the wire. Several variations in the trajectories can be differentiated within the weld zone.

  15. d(−) Lactic Acid-Induced Adhesion of Bovine Neutrophils onto Endothelial Cells Is Dependent on Neutrophils Extracellular Traps Formation and CD11b Expression

    PubMed Central

    Alarcón, Pablo; Manosalva, Carolina; Conejeros, Ivan; Carretta, María D.; Muñoz-Caro, Tamara; Silva, Liliana M. R.; Taubert, Anja; Hermosilla, Carlos; Hidalgo, María A.; Burgos, Rafael A.

    2017-01-01

    Bovine ruminal acidosis is of economic importance as it contributes to reduced milk and meat production. This phenomenon is mainly attributed to an overload of highly fermentable carbohydrate, resulting in increased d(−) lactic acid levels in serum and plasma. Ruminal acidosis correlates with elevated acute phase proteins in blood, along with neutrophil activation and infiltration into various tissues leading to laminitis and aseptic polysynovitis. Previous studies in bovine neutrophils indicated that d(−) lactic acid decreased expression of L-selectin and increased expression of CD11b to concentrations higher than 6 mM, suggesting a potential role in neutrophil adhesion onto endothelia. The two aims of this study were to evaluate whether d(−) lactic acid influenced neutrophil and endothelial adhesion and to trigger neutrophil extracellular trap (NET) production (NETosis) in exposed neutrophils. Exposure of bovine neutrophils to 5 mM d(−) lactic acid elevated NET release compared to unstimulated neutrophil negative controls. Moreover, this NET contains CD11b and histone H4 citrullinated, the latter was dependent on PAD4 activation, a critical enzyme in DNA decondensation and NETosis. Furthermore, NET formation was dependent on d(−) lactic acid plasma membrane transport through monocarboxylate transporter 1 (MCT1). d(−) lactic acid enhanced neutrophil adhesion onto endothelial sheets as demonstrated by in vitro neutrophil adhesion assays under continuous physiological flow conditions, indicating that cell adhesion was a NET- and a CD11b/ICAM-1-dependent process. Finally, d(−) lactic acid was demonstrated for the first time to trigger NETosis in a PAD4- and MCT1-dependent manner. Thus, d(−) lactic acid-mediated neutrophil activation may contribute to neutrophil-derived pro-inflammatory processes, such as aseptic laminitis and/or polysynovitis in animals suffering acute ruminal acidosis. PMID:28861083

  16. Beaver-mediated lateral hydrologic connectivity, fluvial carbon and nutrient flux, and aquatic ecosystem metabolism

    NASA Astrophysics Data System (ADS)

    Wegener, Pam; Covino, Tim; Wohl, Ellen

    2017-06-01

    River networks that drain mountain landscapes alternate between narrow and wide valley segments. Within the wide segments, beaver activity can facilitate the development and maintenance of complex, multithread planform. Because the narrow segments have limited ability to retain water, carbon, and nutrients, the wide, multithread segments are likely important locations of retention. We evaluated hydrologic dynamics, nutrient flux, and aquatic ecosystem metabolism along two adjacent segments of a river network in the Rocky Mountains, Colorado: (1) a wide, multithread segment with beaver activity; and, (2) an adjacent (directly upstream) narrow, single-thread segment without beaver activity. We used a mass balance approach to determine the water, carbon, and nutrient source-sink behavior of each river segment across a range of flows. While the single-thread segment was consistently a source of water, carbon, and nitrogen, the beaver impacted multithread segment exhibited variable source-sink dynamics as a function of flow. Specifically, the multithread segment was a sink for water, carbon, and nutrients during high flows, and subsequently became a source as flows decreased. Shifts in river-floodplain hydrologic connectivity across flows related to higher and more variable aquatic ecosystem metabolism rates along the multithread relative to the single-thread segment. Our data suggest that beaver activity in wide valleys can create a physically complex hydrologic environment that can enhance hydrologic and biogeochemical buffering, and promote high rates of aquatic ecosystem metabolism. Given the widespread removal of beaver, determining the cumulative effects of these changes is a critical next step in restoring function in altered river networks.

  17. Partial wetting gas-liquid segmented flow microreactor.

    PubMed

    Kazemi Oskooei, S Ali; Sinton, David

    2010-07-07

    A microfluidic reactor strategy for reducing plug-to-plug transport in gas-liquid segmented flow microfluidic reactors is presented. The segmented flow is generated in a wetting portion of the chip that transitions downstream to a partially wetting reaction channel that serves to disconnect the liquid plugs. The resulting residence time distributions show little dependence on channel length, and over 60% narrowing in residence time distribution as compared to an otherwise similar reactor. This partial wetting strategy mitigates a central limitation (plug-to-plug dispersion) while preserving the many attractive features of gas-liquid segmented flow reactors.

  18. Process depending morphology and resulting physical properties of TPU

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frick, Achim, E-mail: achim.frick@hs-aalen.de; Spadaro, Marcel, E-mail: marcel.spadaro@hs-aalen.de

    2015-12-17

    Thermoplastic polyurethane (TPU) is a rubber like material with outstanding properties, e.g. for seal applications. TPU basically provides high strength, low frictional behavior and excellent wear resistance. Though, due to segmented structure of TPU, which is composed of hard segments (HSs) and soft segments (SSs), physical properties depend strongly on the morphological arrangement of the phase separated HSs at a certain ratio of HSs to SSs. It is obvious that the TPU deforms differently depending on its bulk morphology. Basically, the morphology can either consist of HSs segregated into small domains, which are well dispersed in the SS matrix ormore » of few strongly phase separated large size HS domains embedded in the SS matrix. The morphology development is hardly ruled by the melt processing conditions of the TPU. Depending on the morphology, TPU provides quite different physical properties with respect to strength, deformation behavior, thermal stability, creep resistance and tribological performance. The paper deals with the influence of important melt processing parameters, such as temperature, pressure and shear conditions, on the resulting physical properties tested by tensile and relaxation experiments. Furthermore the morphology is studied employing differential scanning calorimeter (DSC), transmission light microscopy (TLM), scanning electron beam microscopy (SEM) and transmission electron beam microscopy (TEM) investigations. Correlations between processing conditions and resulting TPU material properties are elaborated. Flow and shear simulations contribute to the understanding of thermal and flow induced morphology development.« less

  19. Bio-medical flow sensor. [intrvenous procedures

    NASA Technical Reports Server (NTRS)

    Winkler, H. E. (Inventor)

    1981-01-01

    A bio-medical flow sensor including a packageable unit of a bottle, tubing and hypodermic needle which can be pre-sterilized and is disposable. The tubing has spaced apart tubular metal segments. The temperature of the metal segments and fluid flow therein is sensed by thermistors and at a downstream location heat is input by a resistor to the metal segment by a control electronics. The fluids flow and the electrical power required for the resisto to maintain a constant temperature differential between the tubular metal segments is a measurable function of fluid flow through the tubing. The differential temperature measurement is made in a control electronics and also can be used to control a flow control valve or pump on the tubing to maintain a constant flow in the tubing and to shut off the tubing when air is present in the tubing.

  20. Progress in cryopreservation of dormant winter buds of selected tree species

    USDA-ARS?s Scientific Manuscript database

    In cryopreservation of germplasm, using dormant winter buds (DB) as source plant materials is economically favorable over tissue culture options (TC). Processing DB does not require aseptic conditions and involved cryopreservation procedures. Although, the DB cryopreservation method has been known f...

  1. Study of flow behavior in all-vanadium redox flow battery using spatially resolved voltage distribution

    NASA Astrophysics Data System (ADS)

    Bhattarai, Arjun; Wai, Nyunt; Schweiss, Rüdiger; Whitehead, Adam; Scherer, Günther G.; Ghimire, Purna C.; Nguyen, Tam D.; Hng, Huey Hoon

    2017-08-01

    Uniform flow distribution through the porous electrodes in a flow battery cell is very important for reducing Ohmic and mass transport polarization. A segmented cell approach can be used to obtain in-situ information on flow behaviour, through the local voltage or current mapping. Lateral flow of current within the thick felts in the flow battery can hamper the interpretation of the data. In this study, a new method of segmenting a conventional flow cell is introduced, which for the first time, splits up both the porous felt as well as the current collector. This dual segmentation results in higher resolution and distinct separation of voltages between flow inlet to outlet. To study the flow behavior for an undivided felt, monitoring the OCV is found to be a reliable method, instead of voltage or current mapping during charging and discharging. Our approach to segmentation is simple and applicable to any size of the cell.

  2. Aseptic Bone Necrosis Among U.S. Navy Divers: Survey of 934 Nonrandomly Selected Personnel

    DTIC Science & Technology

    1977-06-01

    Health, Education, and Welfare, Washington, D.C. Kawashima, M., T. Torisu, K. Hayashi, and Y. Kamo. 1974. Avascular bone necrosis in Japanese diving...5ÜL ^4- P=- 7 RESEM^a^ATORY SUBMARINE BASE, GROTON, CONN. REPORT NUMBER 854 ASEPTIC BONE NECROSIS AMONG U. S. NAVY DIVERS: Survey of 934...Approved for public release; distribution unlimited SUMMARY PAGE THE PROBLEM Aseptic boire~ necrosis tABN) has beelTknown toT5e~ associated with

  3. Six ways not to improve patient flow: a qualitative study.

    PubMed

    Kreindler, Sara Adi

    2017-05-01

    Although well-established principles exist for improving the timeliness and efficiency of care, many organisations struggle to achieve more than small-scale, localised gains. Where care processes are complex and include segments under different groups' control, the elegant solutions promised by improvement methodologies remain elusive. This study sought to identify common design flaws that limit the impact of flow initiatives. This qualitative study was conducted within an explanatory case study of a Canadian regional health system in which multitudinous flow initiatives had yielded no overall improvement in system performance. Interviews with 62 senior, middle and departmental managers, supplemented by ∼700 documents on flow initiatives, were analysed using the constant comparative method. Findings suggested that smooth flow depends on linking a defined population to appropriate capacity by means of an efficient process ; flawed initiatives reflected failure to consider one or more of these essential elements. Many initiatives focused narrowly on process, failing to consider that the intended population was poorly defined or the needed capacity inaccessible; some introduced capacity for an intended population, but offered no process to link the two. Moreover, interveners were unable to respond effectively when a bottleneck moved to another part of the system. Errors of population, capacity and process, in different combinations, generated six 'formulae for failure'. Typically, flawed initiatives focused on too small a segment of the patient journey to properly address the impediments to flow. The proliferation of narrowly focused initiatives, in turn, reflected a decentralised system in which responsibility for flow improvement was fragmented. Thus, initiatives' specific design flaws may have their roots in a deeper problem: the lack of a coherent system-level strategy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Estimates of Median Flows for Streams on the 1999 Kansas Surface Water Register

    USGS Publications Warehouse

    Perry, Charles A.; Wolock, David M.; Artman, Joshua C.

    2004-01-01

    The Kansas State Legislature, by enacting Kansas Statute KSA 82a?2001 et. seq., mandated the criteria for determining which Kansas stream segments would be subject to classification by the State. One criterion for the selection as a classified stream segment is based on the statistic of median flow being equal to or greater than 1 cubic foot per second. As specified by KSA 82a?2001 et. seq., median flows were determined from U.S. Geological Survey streamflow-gaging-station data by using the most-recent 10 years of gaged data (KSA) for each streamflow-gaging station. Median flows also were determined by using gaged data from the entire period of record (all-available hydrology, AAH). Least-squares multiple regression techniques were used, along with Tobit analyses, to develop equations for estimating median flows for uncontrolled stream segments. The drainage area of the gaging stations on uncontrolled stream segments used in the regression analyses ranged from 2.06 to 12,004 square miles. A logarithmic transformation of the data was needed to develop the best linear relation for computing median flows. In the regression analyses, the significant climatic and basin characteristics, in order of importance, were drainage area, mean annual precipitation, mean basin permeability, and mean basin slope. Tobit analyses of KSA data yielded a model standard error of prediction of 0.285 logarithmic units, and the best equations using Tobit analyses of AAH data had a model standard error of prediction of 0.250 logarithmic units. These regression equations and an interpolation procedure were used to compute median flows for the uncontrolled stream segments on the 1999 Kansas Surface Water Register. Measured median flows from gaging stations were incorporated into the regression-estimated median flows along the stream segments where available. The segments that were uncontrolled were interpolated using gaged data weighted according to the drainage area and the bias between the regression-estimated and gaged flow information. On controlled segments of Kansas streams, the median flow information was interpolated between gaging stations using only gaged data weighted by drainage area. Of the 2,232 total stream segments on the Kansas Surface Water Register, 34.5 percent of the segments had an estimated median streamflow of less than 1 cubic foot per second when the KSA analysis was used. When the AAH analysis was used, 36.2 percent of the segments had an estimated median streamflow of less than 1 cubic foot per second. This report supercedes U.S. Geological Survey Water-Resources Investigations Report 02?4292.

  5. Shape complexes: the intersection of label orderings and star convexity constraints in continuous max-flow medical image segmentation

    PubMed Central

    Baxter, John S. H.; Inoue, Jiro; Drangova, Maria; Peters, Terry M.

    2016-01-01

    Abstract. Optimization-based segmentation approaches deriving from discrete graph-cuts and continuous max-flow have become increasingly nuanced, allowing for topological and geometric constraints on the resulting segmentation while retaining global optimality. However, these two considerations, topological and geometric, have yet to be combined in a unified manner. The concept of “shape complexes,” which combine geodesic star convexity with extendable continuous max-flow solvers, is presented. These shape complexes allow more complicated shapes to be created through the use of multiple labels and super-labels, with geodesic star convexity governed by a topological ordering. These problems can be optimized using extendable continuous max-flow solvers. Previous approaches required computationally expensive coordinate system warping, which are ill-defined and ambiguous in the general case. These shape complexes are demonstrated in a set of synthetic images as well as vessel segmentation in ultrasound, valve segmentation in ultrasound, and atrial wall segmentation from contrast-enhanced CT. Shape complexes represent an extendable tool alongside other continuous max-flow methods that may be suitable for a wide range of medical image segmentation problems. PMID:28018937

  6. A Microfabricated Involute-Foil Regenerator for Stirling Engines

    NASA Technical Reports Server (NTRS)

    Tew, Roy; Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gedeon, David; Kelly, Kevin; McLean, Jeffrey; Qiu, Songgang

    2007-01-01

    A segmented involute-foil regenerator has been designed, microfabricated and tested in an oscillating-flow rig with excellent results. During the Phase I effort, several approximations of parallel-plate regenerator geometry were chosen as potential candidates for a new microfabrication concept. Potential manufacturers and processes were surveyed. The selected concept consisted of stacked segmented-involute-foil disks (or annular portions of disks), originally to be microfabricated from stainless-steel via the LiGA (lithography, electroplating, and molding) process and EDM. During Phase II, re-planning of the effort led to test plans based on nickel disks, microfabricated via the LiGA process, only. A stack of nickel segmented-involute-foil disks was tested in an oscillating-flow test rig. These test results yielded a performance figure of merit (roughly the ratio of heat transfer to pressure drop) of about twice that of the 90 percent random fiber currently used in small approx.100 W Stirling space-power convertors-in the Reynolds Number range of interest (50 to 100). A Phase III effort is now underway to fabricate and test a segmented-involute-foil regenerator in a Stirling convertor. Though funding limitations prevent optimization of the Stirling engine geometry for use with this regenerator, the Sage computer code will be used to help evaluate the engine test results. Previous Sage Stirling model projections have indicated that a segmented-involute-foil regenerator is capable of improving the performance of an optimized involute-foil engine by 6 to 9 percent; it is also anticipated that such involute-foil geometries will be more reliable and easier to manufacture with tight-tolerance characteristics, than random-fiber or wire-screen regenerators. Beyond the near-term Phase III regenerator fabrication and engine testing, other goals are (1) fabrication from a material suitable for high temperature Stirling operation (up to 850 C for current engines; up to 1200 C for a potential engine-cooler for a Venus mission), and (2) reduction of the cost of the fabrication process to make it more suitable for terrestrial applications of segmented involute foils. Past attempts have been made to use wrapped foils to approximate the large theoretical figures of merit projected for parallel plates. Such metal wrapped foils have never proved very successful, apparently due to the difficulties of fabricating wrapped-foils with uniform gaps and maintaining the gaps under the stress of time-varying temperature gradients during start-up and shut-down, and relatively-steady temperature gradients during normal operation. In contrast, stacks of involute-foil disks, with each disk consisting of multiple involute-foil segments held between concentric circular ribs, have relatively robust structures. The oscillating-flow rig tests of the segmented-involute-foil regenerator have demonstrated a shift in regenerator performance strongly in the direction of the theoretical performance of ideal parallel-plate regenerators.

  7. A Microfabricated Involute-Foil Regenerator for Stirling Engines

    NASA Technical Reports Server (NTRS)

    Tew, Roy; Ibrahim, Mounir; Danila, Daniel; Simon, Terry; Mantell, Susan; Sun, Liyong; Gedeon, David; Kelly, Kevin; McLean, Jeffrey; Wood, Gary; hide

    2007-01-01

    A segmented involute-foil regenerator has been designed, microfabricated and tested in an oscillating-flow rig with excellent results. During the Phase I effort, several approximations of parallel-plate regenerator geometry were chosen as potential candidates for a new microfabrication concept. Potential manufacturers and processes were surveyed. The selected concept consisted of stacked segmented-involute-foil disks (or annular portions of disks), originally to be microfabricated from stainless-steel via the LiGA (lithography, electroplating, and molding) process and EDM (electric discharge machining). During Phase II, re-planning of the effort led to test plans based on nickel disks, microfabricated via the LiGA process, only. A stack of nickel segmented-involute-foil disks was tested in an oscillating-flow test rig. These test results yielded a performance figure of merit (roughly the ratio of heat transfer to pressure drop) of about twice that of the 90% random fiber currently used in small 100 W Stirling space-power convertors in the Reynolds Number range of interest (50-100). A Phase III effort is now underway to fabricate and test a segmented-involute-foil regenerator in a Stirling convertor. Though funding limitations prevent optimization of the Stirling engine geometry for use with this regenerator, the Sage computer code will be used to help evaluate the engine test results. Previous Sage Stirling model projections have indicated that a segmented-involute-foil regenerator is capable of improving the performance of an optimized involute-foil engine by 6-9%; it is also anticipated that such involute-foil geometries will be more reliable and easier to manufacture with tight-tolerance characteristics, than random-fiber or wire-screen regenerators. Beyond the near-term Phase III regenerator fabrication and engine testing, other goals are (1) fabrication from a material suitable for high temperature Stirling operation (up to 850 C for current engines; up to 1200 C for a potential engine-cooler for a Venus mission), and (2) reduction of the cost of the fabrication process to make it more suitable for terrestrial applications of segmented involute foils. Past attempts have been made to use wrapped foils to approximate the large theoretical figures of merit projected for parallel plates. Such metal wrapped foils have never proved very successful, apparently due to the difficulties of fabricating wrapped-foils with uniform gaps and maintaining the gaps under the stress of time-varying temperature gradients during start-up and shut-down, and relatively-steady temperature gradients during normal operation. In contrast, stacks of involute-foil disks, with each disk consisting of multiple involute-foil segments held between concentric circular ribs, have relatively robust structures. The oscillating-flow rig tests of the segmented-involute-foil regenerator have demonstrated a shift in regenerator performance strongly in the direction of the theoretical performance of ideal parallel-plate regenerators.

  8. Numerical Temperature And Fluid-Flow Modelling For The Topographic Effects On Hydrothermal Circulation; A case study in Lucy Strike Vent Field

    NASA Astrophysics Data System (ADS)

    Erçetin, Engin; Düşünür Doǧan, Doǧa

    2017-04-01

    The aim of the study is to present a numerical temperature and fluid-flow modelling for the topographic effects on hydrothermal circulation. Bathymetry can create a major disturbance on fluid flow pattern. ANSYS Fluent Computational fluid dynamics software is used for simulations. Coupled fluid flow and temperature quations are solved using a 2-Dimensional control volume finite difference approach. Darcy's law is assumed to hold, the fluid is considered to be anormal Boussinesq incompressible fluid neglecting inertial effects. Several topographic models were simulated and both temperature and fluid flow calculations obtained for this study. The preliminary simulations examine the effect of a ingle bathymetric high on a single plume and the secondary study of simulations investigates the effect of multiple bathymetric highs on multiple plume. The simulations were also performed for the slow spreading Lucky Strike segment along the Mid-Atlantic Ridge (MAR), one of the best studied regions along the MAR, where a 3.4 km deep magma chamber extending 6 km along-axis is found at its center. The Lucky Strike segment displays a transitional morphology between that of the FAMOUS - North FAMOUS segments, which are characterized by well-developed axial valleys typical of slow-spreading segments, and that of the Menez Gwen segment, characterized by an axial high at the segment center. Lucky Strike Segment hosts a central volcano and active vent field located at the segment center and thus constitutes an excellent case study to simulate the effects of bathymetry on fluid flow. Results demonstrate that bathymetric relief has an important influence on hydrothermal flow. Subsurface pressure alterations can be formed by bathymetric highs, for this reason, bathymetric relief ought to be considered while simulating hydrothermal circulation systems. Results of this study suggest the dominant effect of bathymetric highs on fluid flow pattern and Darcy velocities will be presented. Keywords: Hydrothermal Circulation, Lucky Strike, Bathymetry - Topography, Vent Location, Fluid Flow, Numerical Modelling

  9. Metagenomic Sequencing of an Echovirus 30 Genome From Cerebrospinal Fluid of a Patient With Aseptic Meningitis and Orchitis.

    PubMed

    Piantadosi, Anne; Mukerji, Shibani S; Chitneni, Pooja; Cho, Tracey A; Cosimi, Lisa A; Hung, Deborah T; Goldberg, Marcia B; Sabeti, Pardis C; Kuritzkes, Daniel R; Grad, Yonatan H

    2017-01-01

    Enteroviruses cause a wide spectrum of clinical disease. In this study, we describe the case of a young man with orchitis and aseptic meningitis who was diagnosed with enterovirus infection. Using unbiased "metagenomic" massively parallel sequencing, we assembled a near-complete viral genome, the first use of this method for full-genome viral sequencing from cerebrospinal fluid. We found that the genome belonged to the subgroup echovirus 30, which is a common cause of aseptic meningitis but has not been previously reported to cause orchitis.

  10. 21 CFR 514.8 - Supplements and other changes to an approved application.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... method(s) or an addition, deletion, or substitution of steps in an aseptic processing operation; (D... solely affecting a natural product, a recombinant DNA-derived protein/polypeptide, or a complex or...) or references to previously approved documentation; (H) For a natural product, a recombinant DNA...

  11. 21 CFR 514.8 - Supplements and other changes to an approved application.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... method(s) or an addition, deletion, or substitution of steps in an aseptic processing operation; (D... solely affecting a natural product, a recombinant DNA-derived protein/polypeptide, or a complex or...) or references to previously approved documentation; (H) For a natural product, a recombinant DNA...

  12. 21 CFR 514.8 - Supplements and other changes to an approved application.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... method(s) or an addition, deletion, or substitution of steps in an aseptic processing operation; (D... solely affecting a natural product, a recombinant DNA-derived protein/polypeptide, or a complex or...) or references to previously approved documentation; (H) For a natural product, a recombinant DNA...

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The model is designed to enable decision makers to compare the economics of geothermal projects with the economics of alternative energy systems at an early stage in the decision process. The geothermal engineering and economic feasibility computer model (GEEF) is written in FORTRAN IV language and can be run on a mainframe or a mini-computer system. An abbreviated version of the model is being developed for usage in conjunction with a programmable desk calculator. The GEEF model has two main segments, namely (i) the engineering design/cost segment and (ii) the economic analysis segment. In the engineering segment, the model determinesmore » the numbers of production and injection wells, heat exchanger design, operating parameters for the system, requirement of supplementary system (to augment the working fluid temperature if the resource temperature is not sufficiently high), and the fluid flow rates. The model can handle single stage systems as well as two stage cascaded systems in which the second stage may involve a space heating application after a process heat application in the first stage.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lieb, K.

    Since aseptic packages, or drink boxes, were introduced in the US in the early 1980s, they have been praised for their convenience and berated for their lack of recyclability. As a result, aseptic packaging collection has been linked with that of milk cartons to increase the volume. The intervening years since the introduction of aseptic packaging have seen the drink box industry aggressively trying to create a recycling market for the boxes. Communities and schools have initiated programs, and recycling firms have allocated resources to see whether recycling aseptic packaging can work. Drink boxes are now recycled in 2.3 millionmore » homes in 15 states, and in 1,655 schools in 17 states. They are typically collected in school and curbside programs with other polyethylene coated (laminated) paperboard products such a milk cartons, and then baled and shipped to five major paper companies for recycling at eight facilities.« less

  15. FABRICA: A Bioreactor Platform for Printing, Perfusing, Observing, & Stimulating 3D Tissues.

    PubMed

    Smith, Lester J; Li, Ping; Holland, Mark R; Ekser, Burcin

    2018-05-15

    We are introducing the FABRICA, a bioprinter-agnostic 3D-printed bioreactor platform designed for 3D-bioprinted tissue construct culture, perfusion, observation, and analysis. The computer-designed FABRICA was 3D-printed with biocompatible material and used for two studies: (1) Flow Profile Study: perfused 5 different media through a synthetic 3D-bioprinted construct and ultrasonically analyzed the flow profile at increasing volumetric flow rates (VFR); (2) Construct Perfusion Study: perfused a 3D-bioprinted tissue construct for a week and compared histologically with a non-perfused control. For the flow profile study, construct VFR increased with increasing pump VFR. Water and other media increased VFR significantly while human and pig blood showed shallow increases. For the construct perfusion study, we confirmed more viable cells in perfused 3D-bioprinted tissue compared to control. The FABRICA can be used to visualize constructs during 3D-bioprinting, incubation, and to control and ultrasonically analyze perfusion, aseptically in real-time, making the FABRICA tunable for different tissues.

  16. Deformation of host rocks and flow of magma during growth of minette dikes and breccia-bearing intrusions near Ship Rock, New Mexico

    USGS Publications Warehouse

    Delaney, Paul T.; Pollard, David D.

    1981-01-01

    We have studied a small group of minette dikes and plugs that crop out within a flat-lying sequence of siltstone and shale near Ship Rock, a prominent volcanic throat of tuff breccia in northwestern New Mexico. Seven dikes form a radial pattern about Ship Rock we describe in detail the northeastern dike, which has an outcrop length of about 2,900 m, an average thickness of 2.3 m, and a maximum thickness of 7.2 m. The dike is composed of 35 discrete segments arranged in echelon; orientation. of dike segments ranges systematically from N. 52? E. to N. 66? E. A prominent joint set strikes parallel to the segments and is localized within several tens of meters of the dike. Regional joint patterns display no obvious relation to dike orientation. Small offsets of segment contacts, as well as wedge-shaped bodies of crumpled host rock within segments mark the sites of coalescence of smaller segments during dike growth. Bulges in the dike contact, which represent a nondilational component of growth, indicate that wall rocks were brecciated and eroded during the flow of magma. Breccias make up about 9 percent of the 7,176-m 2 area of the dike, are concentrated in its southwest half, and are commonly associated with its thickest parts. We also describe three subcircular plugs; each plug is smaller than 30 m in diameter, is laterally associated with a dike, and contains abundant breccias. Field evidence indicates that these plugs grew from the dikes by brecciation and erosion of wallrocks and that the bulges in the contact of the northeastern dike represent an initial stage of this process. From continuum-mechanical models of host-rock deformation, we conclude that dike propagation was the dominant mechanism for creating conduits for magma ascent where the host rock was brittle and elastic. At a given driving pressure, dikes dilate to accept greater volumes of magma than plugs, and for a given dilation, less work is done on the host rocks. In addition, the pressure required for dike growth decreases with dike length. From numerical solutions for dilation of cracks oriented like segments of the northeastern dike, we find that we can best model the form of the dike by treating it as composed of 10 cracks rather than 35. We attribute this result to coalescence of adjacent segments below the present outcrop and to inelastic deformation at segment ends. Using a driving pressure of 2 MPa (20 bars), we estimate a shear modulus of about 10^3 MPa for the host rocks, in agreement with laboratory tests on soft shale. A propagation criterion based on stress intensity at the segment ends indicates a fracture toughness of the host rocks of about 100 MPa-m^? , a hundredfold greater than values reported from laboratory tests. Segmentation of fractures is common in many materials and has been observed during fissure eruptions at Kilauea Volcano in Hawaii. At the northeastern dike, we attribute segmentation to local rotation of the direction of least principal compressive stress. From continuum-mechanical models of magma and heat flow in idealized conduits, we conclude that magma flows far more rapidly and with less relative heat loss in plugs than in dikes. Although dikes are the preferred form for emplacement, plugs are the preferred form for the flow of magma. We present a numerical solution for volumetric flow rate and wall heat flux for the northeastern dike and find that although the flow rate is extremely sensitive to conduit geometry, the rate of heat loss to wall rocks is not. During emplacement of the northeastern dike, local flow rate increased where wall rocks were eroded and reached a maximum of about 45 times the mean initial rate, whereas the maximum rate of heat loss to wallrocks increased to only 1.6 times the mean initial rate. An inferred progression from continuous magma flow along a dike to flow from a plug agrees well with observations of volcanic eruptions that begin from fissures and later are localized at discrete vents. We

  17. Thermal regime of the San Andreas fault near Parkfield, California

    USGS Publications Warehouse

    Sass, J.H.; Williams, C.F.; Lachenbruch, A.H.; Galanis, S.P.; Grubb, F.V.

    1997-01-01

    Knowledge of the temperature variation with depth near the San Andreas fault is vital to understanding the physical processes that occur within the fault zone during earthquakes and creep events. Parkfield is near the southern end of the Coast Ranges segment of the San Andreas fault. This segment has higher mean heat flow than the Cape Mendocino segment to the northwest or the Mojave segment to the southeast. Boreholes were drilled specifically for the U.S. Geological Survey's Parkfield earthquake prediction experiment or converted from other uses at 25 sites within a few kilometers of the fault near Parkfield. These holes, which range in depth from 150 to over 1500 m, were intended mainly for the deployment of volumetric strain meters, water-level recorders, and other downhole instruments. Temperature profiles were obtained from all the holes, and heat flow values were estimated from 17 of them. For a number of reasons, including a paucity of thermal conductivity data and rugged local topography, the accuracy of individual determinations was not sufficiently high to document local variations in heat flow. Values range from 54 to 92 mW m-2, with mean and 95% confidence limits of 74 ?? 4 mW m-2. This mean is slightly lower than the mean (83 ?? 3) of 39 previously published values from the central Coast Ranges, but it is consistent with the overall pattern of elevated heat flow in the Coast Ranges, and it is transitional to the mean of 68 ?? 2 mW m-2 that characterizes the Mojave segment of the San Andreas fault immediately to the south. The lack of a heat flow peak near the fault underscores the absence of a frictional thermal anomaly and provides additional support for a very small resolved shear stress parallel to the San Andreas fault and the nearly fault-normal maximum compressive stress observed in this region. Estimates of subsurface thermal conditions indicate that the seismic-aseismic transition for the Parkfield segment corresponds to temperatures in the range of 350??-400??C. Increasing heat flow to the northwest of Parkfield corresponds to a transition from locked to creeping sections and to a shallowing of the base of seismicity and confirms the importance of temperature in controlling the thickness of the seismogenic crust. Lateral variations in heat flow do not appear to have any major role in determining the regularity of M5.5-6 earthquakes at Parkfield.

  18. Application guide for AFINCH (Analysis of Flows in Networks of Channels) described by NHDPlus

    USGS Publications Warehouse

    Holtschlag, David J.

    2009-01-01

    AFINCH (Analysis of Flows in Networks of CHannels) is a computer application that can be used to generate a time series of monthly flows at stream segments (flowlines) and water yields for catchments defined in the National Hydrography Dataset Plus (NHDPlus) value-added attribute system. AFINCH provides a basis for integrating monthly flow data from streamgages, water-use data, monthly climatic data, and land-cover characteristics to estimate natural monthly water yields from catchments by user-defined regression equations. Images of monthly water yields for active streamgages are generated in AFINCH and provide a basis for detecting anomalies in water yields, which may be associated with undocumented flow diversions or augmentations. Water yields are multiplied by the drainage areas of the corresponding catchments to estimate monthly flows. Flows from catchments are accumulated downstream through the streamflow network described by the stream segments. For stream segments where streamgages are active, ratios of measured to accumulated flows are computed. These ratios are applied to upstream water yields to proportionally adjust estimated flows to match measured flows. Flow is conserved through the NHDPlus network. A time series of monthly flows can be generated for stream segments that average about 1-mile long, or monthly water yields from catchments that average about 1 square mile. Estimated monthly flows can be displayed within AFINCH, examined for nonstationarity, and tested for monotonic trends. Monthly flows also can be used to estimate flow-duration characteristics at stream segments. AFINCH generates output files of monthly flows and water yields that are compatible with ArcMap, a geographical information system analysis and display environment. Chloropleth maps of monthly water yield and flow can be generated and analyzed within ArcMap by joining NHDPlus data structures with AFINCH output. Matlab code for the AFINCH application is presented.

  19. Endoglin (CD105) expression differentiates between aseptic loosening and periprosthetic joint infection after total joint arthroplasty.

    PubMed

    Jansen, Philipp; Mumme, Torsten; Randau, Thomas; Gravius, Sascha; Hermanns-Sachweh, Benita

    2014-01-01

    The differentiation between aseptic loosening and periprosthetic joint infection (PJI) after total joint arthroplasty is essential for successful therapy. A better understanding of pathogenesis of aseptic loosening and PJI may help to prevent or treat these complications. Previous investigations revealed an increased vascularization in the periprosthetic membrane in cases of PJI via PET signals. Based on these findings our hypothesis was that PJI is associated with an increased neovascularization in the periprosthetic membrane. Tissue samples from periprosthetic membranes of the bone-implant interface were investigated histologically for inflammation, wear particles, vascularization and fibrosis. To identify vascular structures antibodies against CD 31, CD 34, factor VIII and CD 105 (endoglin) were applied for immunohistochemical investigations. According to a consensus classification of Morawietz the tissue samples were divided into four types: type I (wear particle induced type, n = 11), type II (infectious type, n = 7), type III (combined type, n = 7) and type IV (indeterminate type, n = 7). Patients with PJI (type II) showed a pronounced infiltration of neutrophil granulocytes in the periprosthetic membrane and an enhanced neovascularization indicated by positive immunoreaction with antibodies against CD 105 (endoglin). Tissue samples classified as type I, type III and type IV showed significantly less immune reaction for CD 105. In cases of aseptic loosening and PJI vascularization is found in different expression in periprosthetic membranes. However, in aseptic loosening, there is nearly no neovascularization with CD 105-positive immune reaction. Therefore, endoglin (CD 105) expression allows for differentiation between aseptic loosening and PJI.

  20. Human enteroviruses in cerebrospinal fluid of children with suspected aseptic meningitis: A study in northern Iran.

    PubMed

    Sadeghi, Farzin; Talebi-Nesami, Masoumeh; Barari-Savadkouhi, Rahim; Bijani, Ali; Ferdosi-Shahandashti, Elahe; Yahyapour, Yousef

    2017-01-01

    Enterovirus (EV) infections are one of the most common causes of aseptic meningitis in pediatrics. To diagnose EV meningitis, virus isolation in cell cultures is often time consuming and lacks sensitivity to be of clinical relevance. This makes the virus culture results difficult to interpret. The rapid detection of EVs in cerebrospinal fluid (CSF) by molecular diagnostic techniques may improve the management of patients with aseptic meningitis. The purpose of the present study was to develop a more convenient and sensitive alternative technique to viral culture. The current investigation aimed to explore the prevalence of EVs in CSF of children with suspected aseptic meningitis in northern Iran, between June 2014 and March 2015 via the one-step real-time RT-PCR technique. A single center cross-sectional study was carried out on 50 children suspected with aseptic meningitis, aged 6 months to 13 years. The presence of EV RNA in CSF samples was screened by the use of qualitative one-step real-time RT-PCR. Enteroviral RNA was detected in 9 (18%) subjects using the one-step real-time RT-PCR assay. There was significant difference between EV positive and negative subjects regarding mean age (P=0.023), mean lymphocyte percentage (P=0.001) and mean glucose levels in CSF (P=0.037). The disease onset data indicate that the majority of EV meningitis occurred in the summer. This study provides the first data on the prevalence and epidemiology of EV infections in children with suspected aseptic meningitis in northern Iran.

  1. Molecular characterization of echovirus 30-associated outbreak of aseptic meningitis in Korea in 2008.

    PubMed

    Choi, Young Jin; Park, Kwi Sung; Baek, Kyoung Ah; Jung, Eun Hye; Nam, Hae Seon; Kim, Yong Bae; Park, Joon Soo

    2010-03-01

    Evaluation of the primary etiologic agents that cause aseptic meningitis outbreaks may provide valuable information regarding the prevention and management of aseptic meningitis. In Korea, an outbreak of aseptic meningitis caused by echovirus type 30 (E30) occurred from May to October in 2008. In order to determine the etiologic agent, CSF and/or stool specimens from 140 children hospitalized for aseptic meningitis at Soonchunhyang University Cheonan Hospital between June and October of 2008 were tested for virus isolation and identification. E30 accounted for 61.7% (37 cases) and echovirus 6 accounted for 21.7% (13 cases) of all the human enteroviruses (HEVs) isolates (60 cases in total). For the molecular characterization of the isolates, the VP1 gene sequence of 18 Korean E30 isolates was compared pairwise using the MegAlign with 34 reference strains from the GenBank database. The pairwise comparison of the nucleotide sequences of the VP1 genes demonstrated that the sequences of the Korean strains differed from those of lineage groups A, B, C, D, E, F and G. Reconstruction of the phylogenetic tree based on the complete VP1 nucleotide sequences resulted in a monophyletic tree, with eight clustered lineage groups. All Korean isolates were segregated from other lineage groups, thus suggesting that the Korean strains were a distinct lineage of E30, and a probable cause of this outbreak. This manuscript is the first report, to the best of our knowledge, of the molecular characteristics of E30 strains associated with an aseptic meningitis outbreak in Korea, and their respective phylogenetic relationships.

  2. Feasibility Study on a Segmented Ferrofluid Flow Linear Generator for Increasing the Time-Varying Magnetic Flux.

    PubMed

    Lee, Won-Ho; Lee, Se-Hee; Lee, Sangyoup; Lee, Jong-Chul

    2018-09-01

    Nanoparticles and nanofluids have been implemented in energy harvesting devices, and energy harvesting based on magnetic nanofluid flow was recently achieved by using a layer-built magnet and micro-bubble injection to induce a voltage on the order of 10-1 mV. However, this is not yet suitable for some commercial purpose. In order to further increase the amount of electric voltage and current from this energy harvesting the air bubbles must be segmented in the base fluid, and the magnetic flux of the segmented flow should be materially altered over time. The focus of this research is on the development of a segmented ferrofluid flow linear generator that would scavenge electrical power from waste heat. Experiments were conducted to obtain the induced voltage, which was generated by moving a ferrofluid-filled capsule inside a multi-turn coil. Computations were then performed to explain the fundamental physical basis of the motion of the segmented flow of the ferrofluids and the air-layers.

  3. Rocks Whose Compositions are Determined by Flow Differentiation of Olivine- and Sulfide Droplet-Laden Magma: the Jinchuan Story

    NASA Astrophysics Data System (ADS)

    Li, C.; Ripley, E. M.; de Waal, S. A.; Xu, Z.

    2002-12-01

    The Jinchuan intrusion in western China is an elongated, deeply-dipping dyke-like body of dominantly olivine-rich ultramafic rocks of high magnesium basaltic magma. It hosts the second largest Ni-Cu sulfide deposit in the world. More than 500 million tones of sulfide ore grading 1.2 percent Ni and 0.7 percent Cu occur mostly as next-textured and disseminated sulfide (pyrrhotite, pentlendite and chalcopyrite) with cumulus olivine in about half of the rocks of the intrusion. Based on different petrological zonations, the Jinchuan intrusion is further divided into three segments: eastern, central and western segments. The central segment is characterized by concentric enrichments of cumulus olivine and sulfide, whereas the eastern and western segments are characterized by the increase of both cumulus olivine and sulfide toward the footwall. The forsterite contents of fresh olivine from different segments are similar and vary between 82 and 86 mole percent. The small range of olivine compositional variation corresponds to less than 6 percent of fractional crystallization. Mass balance calculations based on sulfide solubility in basaltic magma indicate that the volume of the parental magma of the sulfide is many times larger than that which is currently represented in the intrusion. Large amounts of cumulus olivine (more than 40 weight percent) in the marginal samples and high concentrations of sulfide in the intrusion are consistent with an interpretation that the Jinchuan intrusion was formed by olivine- and sulfide droplet-laden magma ascending through a subvertical conduit to a higher level. Differentiation processes of the olivine- and sulfide droplet-laden magma varied in different parts of the conduit. Sub-vertical flow differentiation controlled the central segment of the conduit, resulting in further enrichment of olivine crystals and sulfide droplets in the conduit center. In contrast, sub-lateral flow and gravitational differentiation dominated in the eastern and western segments, resulting in further enrichments of olivine crystals and sulfide droplets toward the footwall contact.

  4. Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

    PubMed

    Streit, Marcus R; Haeussler, Daniel; Bruckner, Thomas; Proctor, Tanja; Innmann, Moritz M; Merle, Christian; Gotterbarm, Tobias; Weiss, Stefan

    2016-07-01

    Excessive early migration of cemented stems and cups after THA has been associated with poor long-term survival and allows predictable evaluation of implant performance. However, there are few data regarding the relationship between early migration and aseptic loosening of cementless femoral components, and whether early migration might predict late failure has not been evaluated, to our knowledge. Einzel-Bild-Röntgen-Analyse-femoral component analysis (EBRA-FCA) is a validated technique to accurately measure axial femoral stem migration without the need for tantalum markers, can be performed retrospectively, and may be a suitable tool to identify poor performing implants before their widespread use. We asked: (1) Is axial migration within the first 24 months as assessed by EBRA-FCA greater among cementless stems that develop aseptic loosening than those that remain well fixed through the second decade; (2) what is the diagnostic performance of implant migration at 24 months postoperatively to predict later aseptic loosening of these components; and (3) how does long-term stem survivorship compare between groups with high and low early migration? We evaluated early axial stem migration in 158 cementless THAs using EBRA-FCA. The EBRA-FCA measurements were performed during the first week postoperatively (baseline measurement) and at regular followups of 3, 6, and 12 months postoperatively and annually thereafter. The mean duration of followup was 21 years (range, 18-24 years). The stems studied represented 45% (158 of 354) of the cementless THAs performed during that time, and cementless THAs represented 34% (354 of 1038) of the THA practice during that period. No patient enrolled in this study was lost to followup. Multivariate survivorship analysis using Cox's regression model was performed with an endpoint of aseptic loosening of the femoral component. Loosening was defined according to the criteria described by Engh et al. and assessed by two independent observers. Patients with a diagnosis of prosthetic joint infection were excluded. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance of axial stem migration 1, 2, 3, and 4 years postoperatively as a predictor of aseptic loosening. Survivorship of hips with high (≥ 2.7 mm) and low (< 2.7 mm) migration was compared using a competing-events analysis. Femoral components that had aseptic loosening develop showed greater mean distal migration at 24 months postoperatively than did components that remained well fixed throughout the surveillance period (4.2 mm ± 3.1 mm vs 0.8 mm ± 0.9 mm; mean difference, 3.4 mm, 95% CI, 2.5-4.4; p ≤ 0.001). Distal migration at 24 months postoperatively was a strong risk factor for aseptic loosening (hazard ratio, 1.98; 95% CI, 1.51-2.57; p < 0.001). The associated overall diagnostic performance of 2-year distal migration for predicting aseptic loosening was good (area under the ROC curve, 0.86; 95% CI, 0.72-1.00; p < 0.001). Sensitivity of early migration measurement was high for the prediction of aseptic loosening during the first decade after surgery but decreased markedly thereafter. Stems with large amounts of early migration (≥ 2.7 mm) had lower 18-year survivorship than did stems with little early migration (29% [95% CI, 0%-62%] versus 95% [95% CI, 90%-100%] p < 0.001). Early migration, as measured by EBRA-FCA at 2 years postoperatively, has good diagnostic capabilities for detection of uncemented femoral components at risk for aseptic loosening during the first and early second decades after surgery. However, there was no relationship between early migration patterns and aseptic loosening during the late second and third decades. EBRA-FCA can be used as a research tool to evaluate new cementless stems or in clinical practice to evaluate migration patterns in patients with painful femoral components. Level III, diagnostic study.

  5. A simple scaled down system to mimic the industrial production of first generation fuel ethanol in Brazil.

    PubMed

    Raghavendran, Vijayendran; Basso, Thalita Peixoto; da Silva, Juliana Bueno; Basso, Luiz Carlos; Gombert, Andreas Karoly

    2017-07-01

    Although first-generation fuel ethanol is produced in Brazil from sugarcane-based raw materials with high efficiency, there is still little knowledge about the microbiology, the biochemistry and the molecular mechanisms prevalent in the non-aseptic fermentation environment. Learning-by-doing has hitherto been the strategy to improve the process so far, with further improvements requiring breakthrough technologies. Performing experiments at an industrial scale are often expensive, complicated to set up and difficult to reproduce. Thus, developing an appropriate scaled down system for this process has become a necessity. In this paper, we present the design and demonstration of a simple and effective laboratory-scale system mimicking the industrial process used for first generation (1G) fuel ethanol production in the Brazilian sugarcane mills. We benchmarked this system via the superior phenotype of the Saccharomyces cerevisiae PE-2 strain, compared to other strains from the same species: S288c, baker's yeast, and CEN.PK113-7D. We trust that such a system can be easily implemented in different laboratories worldwide, and will allow a better understanding of the S. cerevisiae strains that can persist and dominate in this industrial, non-aseptic and peculiar environment.

  6. A database of aerothermal measurements in hypersonic flow for CFD validation

    NASA Technical Reports Server (NTRS)

    Holden, M. S.; Moselle, J. R.

    1992-01-01

    This paper presents an experimental database selected and compiled from aerothermal measurements obtained on basic model configurations on which fundamental flow phenomena could be most easily examined. The experimental studies were conducted in hypersonic flows in 48-inch, 96-inch, and 6-foot shock tunnels. A special computer program was constructed to provide easy access to the measurements in the database as well as the means to plot the measurements and compare them with imported data. The database contains tabulations of model configurations, freestream conditions, and measurements of heat transfer, pressure, and skin friction for each of the studies selected for inclusion. The first segment contains measurements in laminar flow emphasizing shock-wave boundary-layer interaction. In the second segment, measurements in transitional flows over flat plates and cones are given. The third segment comprises measurements in regions of shock-wave/turbulent-boundary-layer interactions. Studies of the effects of surface roughness of nosetips and conical afterbodies are presented in the fourth segment of the database. Detailed measurements in regions of shock/shock boundary layer interaction are contained in the fifth segment. Measurements in regions of wall jet and transpiration cooling are presented in the final two segments.

  7. Dual infection with hepatitis A and E virus presenting with aseptic meningitis: a case report.

    PubMed

    Naha, Kushal; Karanth, Suman; Prabhu, Mukhyaprana; Sidhu, Manpreet Singh

    2012-07-01

    We report the case of a young male who presented with features of aseptic meningitis and elevated serum liver enzymes, but no symptoms or signs suggestive of an acute hepatitis. Subsequently, he was diagnosed with dual infection with hepatitis A and E viruses, and recovered completely with symptomatic therapy. Isolated aseptic meningitis, unaccompanied by hepatitic features is an unusual presentation of a hepatotrophic viral infection, and is yet to be reported with hepatitis A and E virus co-infection. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  8. Optic neuritis following aseptic meningitis associated with modified measles: a case report.

    PubMed

    Nakajima, Nobuhito; Ueda, Masayuki; Yamazaki, Mineo; Takahashi, Toshiyuki; Katayama, Yasuo

    2013-01-01

    In this study, we report the case of a 35-year-old woman with modified measles complicated by aseptic meningitis and subsequent optic neuritis. Although her initial manifestations were only flu-like symptoms without any Koplik's spots or skin rashes, virological testing confirmed an acute measles infection. Subsequently, right optic neuritis appeared after aseptic meningitis and was completely resolved following steroid pulse therapy. In general, modified measles is believed to be associated with mild symptoms and few neurological complications; however, our present observations demonstrated that modified measles can cause rapid neurological complications.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, J.C.; Reiss, R.J.; Rica, A.F.

    There is disclosed an aseptic flexible walled container having a rigid fitment member cooperative with an aseptic filling apparatus and including a neck, outer flanges surrounding the neck, a frangible membrane and an outer end rim receptive of an hermetically sealed lid. The neck is formed with an internal chamferred seating shoulder for fluid-tight engagement with a fill tube. One outer flange cooperates with clamping jaws of the aseptic filling apparatus for detachably sealing the fitment to a sterilizing chamber and placing it in position for insertion of the filling tube which ruptures the membrane and permits the aseptic introductionmore » of product to the container's interior. The other outer flange is secured to an opening in a wall of the flexible container. The joined fitment and container are presterilized prior to filling. Selected materials for the multi-ply container walls and the fitment permit the container to withstand gamma ray and other sterilization treatment, heat and pressure while maintaining required strength. After the container is aseptically filled, such as with flowable food product, the fill tube is withdrawn and a lid is hermetically sealed onto the rim of the fitment. A heat shield adjacent a container wall surrounds the fitment to protect the container from excessive heat generated by the associated filling apparatus during filling.« less

  10. Apparatus and method for plasma processing of SRF cavities

    NASA Astrophysics Data System (ADS)

    Upadhyay, J.; Im, Do; Peshl, J.; Bašović, M.; Popović, S.; Valente-Feliciano, A.-M.; Phillips, L.; Vušković, L.

    2016-05-01

    An apparatus and a method are described for plasma etching of the inner surface of superconducting radio frequency (SRF) cavities. Accelerator SRF cavities are formed into a variable-diameter cylindrical structure made of bulk niobium, for resonant generation of the particle accelerating field. The etch rate non-uniformity due to depletion of the radicals has been overcome by the simultaneous movement of the gas flow inlet and the inner electrode. An effective shape of the inner electrode to reduce the plasma asymmetry for the coaxial cylindrical rf plasma reactor is determined and implemented in the cavity processing method. The processing was accomplished by moving axially the inner electrode and the gas flow inlet in a step-wise way to establish segmented plasma columns. The test structure was a pillbox cavity made of steel of similar dimension to the standard SRF cavity. This was adopted to experimentally verify the plasma surface reaction on cylindrical structures with variable diameter using the segmented plasma generation approach. The pill box cavity is filled with niobium ring- and disk-type samples and the etch rate of these samples was measured.

  11. [Coral as support of traumatic articular compression. A prospective study of 23 cases involving the lower limb].

    PubMed

    de Peretti, F; Trojani, C; Cambas, P M; Loubière, R; Argenson, C

    1996-01-01

    Infection risk makes the management of a bone bank more and more difficult. On the other hand, realizing an autologous graft is not always without consequences. That is why we estimated the mechanical quality, the osteo-integration and the biocompatability of a coral graft. Between 1988 and 1992, two of us systematically used coral graft as "support" after lifting of some articular depression in fractures of inferior limb. Osteosynthesis was systematically associated. In this way, we operated 13 fractures of the lateral tibial plateau, 8 thalamic fractures of the calcaneus and 2 fractures of the inferior extremity of the tibia. Average follow-up is 20 months, with extremes of 68 and 12 months. Material ablation was realized 13 times and coral graft biopsy 4 times. Bone integration was estimated radiologically in 3 stages: stage 1: non union = "margin" around the coral, stage 2: possible integration = the coral is perfectly visible, but its borders grow indistinct, stage 3: certain integration = peripheral disparition of the coral weft, radiological interpenetration between coral and bone framework. We systematically searched for secondary displacements and complications. Mechanical conditions were respected, there was no secondary displacement. "Possible integration" (stage 2) was found in 8 cases at an average follow-up of 20 months. In 9 cases, we found "certain integration" (stage 3), at an average follow-up of 28 months. It is possible that a more important follow-up time would allow to find more integration cases. Biocompatibility is debatable under the operating conditions of the authors. We counted 5 aseptic serous flows which continued to be aseptic (1 tibial plateau, 1 inferior extremity of the tibia, 3 calcaneum). Three coral grafts were removed to obtain healing. When biocompatibility is satisfactory the integration is certain. The longer the follow-up time, the more stage 3 cases can be observed. Nevertheless, this integration runs out with time. We did not find any explication to aseptic serous flows. It may result from some impurities. On the other hand, use of the coralin hydroxyapatite does not seem to drive to allergic complications. In accordance with this study, we use the coral graft only in case of tibial plateau fracture. Our experience with coral graft in the other fields of bone surgery is not sufficient to express an opinion.

  12. Non-invasive energy meter for fixed and variable flow systems

    DOEpatents

    Menicucci, David F.; Black, Billy D.

    2005-11-01

    An energy metering method and apparatus for liquid flow systems comprising first and second segments of one or more conduits through which a liquid flows, comprising: attaching a first temperature sensor for connection to an outside of the first conduit segment; attaching a second temperature sensor for connection to an outside of the second conduit segment; via a programmable control unit, receiving data from the sensors and calculating energy data therefrom; and communicating energy data from the meter; whereby the method and apparatus operate without need to temporarily disconnect or alter the first or second conduit segments. The invention operates with both variable and fixed flow systems, and is especially useful for both active and passive solar energy systems.

  13. Dripping from Rough Multi-Segmented Fracture Sets into Unsaturated Rock Underground Excavations

    NASA Astrophysics Data System (ADS)

    Cesano, D.; Bagtzoglou, A. C.

    2001-05-01

    The aim of this paper is to present a probabilistic analytical formulation of unsaturated flow through a single rough multi-segmented fracture, with the ultimate goal to provide a numerical platform with which to perform calculations on the dripping initiation time and to explain the fast flow-paths detected and reported by Fabryka-Martin et al. (1996). To accomplish this, an enhanced version of the Wang and Narasimhan model (Wang and Narasimhan, 1985; 1993), the Enhanced Wang and Narasimhan Model (EWNM), has been used. In the EWNM, a fracture is formed by a finite number of connected fracture segments of given strike and dip. These parameters are sampled from hypothetical probability density functions. Unsaturated water flow occurs in these fracture segments, and in order for dripping to occur it is assumed that local saturation conditions exist at the surface and the tunnel level, where dripping occurs. The current version of the EWNM ignores transient flow processes, and thus it assumes the flow system being at equilibrium. The fracture segments are considered as rough fractures, with their roughness characterized by an aperture distribution function that can be derived from real field data. The roughness along each fracture segment is considered to be constant, leading to a constant effective aperture, and it is randomly assigned. An effective flow area is also included in the model, which accounts for three-dimensional variations of the fracture area that can be possibly occupied by water. The model takes into account the possibility that the fracture crosses multiple layers, each of which can have a different configuration in the values of the input parameters. Monte Carlo simulations calculate average times for water to flow from the top to the bottom of the fracture for a specified number of random realizations. The random component of the realizations comprises the different geometric configurations of the fracture flow path, while the value of all the input parameters and the statistical distribution they honor are kept constant from realization to realization. This travel time, called the dripping initiation time, is the cumulative sum of the time it takes for the water to drip through all fracture segments and eventually reach the tunnel. Based on the results of a sensitivity analysis, three different scenarios of input parameters were used to test the validity of the model with the fast flow-paths detected and reported in the Fabryka-Martin et al. (1996) study. The three scenarios differed from each other for the response of the dripping initiation times. These three different parameter configurations were then tested at three different depths. Each depth represented a different location where fast-flow has been detected at Yucca Mountain and reported by Fabryka-Martin et al. (1996). The first depth is considered representative of a location in correspondence to the Bow Ridge Fault. The second location represents a network of steep fractures and cooling joints with large variability in dip reaching the ESF at a depth of 180 meters. The third location, which is probably connected to the Diabolous Ridge Fault, is 290 meters deep and the flow path is low-dipping. Monte Carlo simulations were run for each configuration at each depth to calculate average dripping initiation times, so that results from 9 scenarios were produced. The final conclusion is that the model is able to produce results quite consistent with the Fabryka-Martin et al. (1996) study.

  14. 21 CFR 120.25 - Process verification for certain processors.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... accuracy, precision, and sensitivity in detecting E. coli. This method is designed to detect the presence... times: (i) Aseptically inoculate 10 mL of juice into 90 mL of Universal Preenrichment Broth (Difco) and... series of seven tests are positive for E. coli, the control measures to attain the 5-log reduction...

  15. 21 CFR 120.25 - Process verification for certain processors.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accuracy, precision, and sensitivity in detecting E. coli. This method is designed to detect the presence... times: (i) Aseptically inoculate 10 mL of juice into 90 mL of Universal Preenrichment Broth (Difco) and... series of seven tests are positive for E. coli, the control measures to attain the 5-log reduction...

  16. Infection control practices for dental radiography.

    PubMed

    Palenik, Charles John

    2004-06-01

    Infection control for dental radiography employs the same materials, processes, and techniques used in the operatory, yet unless proper procedures are established and followed, there is a definite potential for cross-contamination to clinical area surfaces and DHCP. In general, the aseptic practices used are relatively simple and inexpensive, yet they require complete application in every situation.

  17. Correlations between topography and intraflow width behavior in Martian and terrestrial lava flows

    NASA Astrophysics Data System (ADS)

    Peitersen, Matthew N.; Crown, David A.

    2000-02-01

    Local correlations between topography and width behavior within lava flows at Puu Oo, Mount Etna, Glass Mountain, Cerro Bayo, Alba Patera, Tyrrhena Patera, Elysium Mons, and Olympus Mons were investigated. For each flow, width and slope data were both referenced via downflow distance as a sequence of points; the data were then divided into collections of adjacent three-point features and two-point segments. Four discrete types of analyses were conducted: (1) Three-point analysis examined positional correlations between width and slope features, (2) two-point analysis did the same for flow segments, (3) mean slope analysis included segment slope comparisons, and (4) sudden width behavior analysis measured abruptness of width changes. The distribution of types of correlations compared to random combinations of features and segments does not suggest a significant correlation between flow widths and local underlying slopes and indicates that for these flows at least, other factors have more influence on changes in width than changes in underlying topography. Mean slopes underlying narrowing, widening, and constant flow width segments were calculated. An inverse correlation between slope and width was found only at Mount Etna, where slopes underlying narrowing segments were greater than those underlying widening in 62% of the examined flows. For the majority of flows at Mount Etna, Puu Oo, and Olympus Mons, slopes were actually greatest under constant width segments; this may imply a topographically dependent resistance to width changes. The rate of change of width was also examined. Sudden width changes are relatively common at Puu Oo, Mount Etna, Elysium Mons, and Tyrrhena Patera and relatively rare at Glass Mountain, Cerro Bayo, Olympus Mons, and Alba Patera. After correction for mapping scale, Puu Oo, Mount Etna, Olympus Mons, and Alba Patera appear to fall on the same trend; Glass Mount exhibits unusually small amounts of sudden width behavior, and Tyrrhena Patera exhibits a relatively large number of sudden width behavior occurrences.

  18. Key Features of the Deployed NPP/NPOESS Ground System

    NASA Astrophysics Data System (ADS)

    Heckmann, G.; Grant, K. D.; Mulligan, J. E.

    2010-12-01

    The National Oceanic & Atmospheric Administration (NOAA), Department of Defense (DoD), and National Aeronautics & Space Administration (NASA) are jointly acquiring the next-generation weather/environmental satellite system; the National Polar-orbiting Operational Environmental Satellite System (NPOESS). NPOESS replaces the current NOAA Polar-orbiting Operational Environmental Satellites (POES) and DoD Defense Meteorological Satellite Program (DMSP). NPOESS satellites carry sensors to collect meteorological, oceanographic, climatological, and solar-geophysical data of the earth, atmosphere, and space. The ground data processing segment is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence & Information Systems (IIS). The IDPS processes NPOESS Preparatory Project (NPP)/NPOESS satellite data to provide environmental data products/records (EDRs) to NOAA and DoD processing centers operated by the US government. The IDPS will process EDRs beginning with NPP and continuing through the lifetime of the NPOESS system. The command & telemetry segment is the Command, Control & Communications Segment (C3S), also developed by Raytheon IIS. C3S is responsible for managing the overall NPP/NPOESS missions from control & status of the space and ground assets to ensuring delivery of timely, high quality data from the Space Segment to IDPS for processing. In addition, the C3S provides the globally-distributed ground assets needed to collect and transport mission, telemetry, and command data between the satellites and processing locations. The C3S provides all functions required for day-to-day satellite commanding & state-of-health monitoring, and delivery of Stored Mission Data to each Central IDP for data products development and transfer to system subscribers. The C3S also monitors and reports system-wide health & status and data communications with external systems and between the segments. The C3S & IDPS segments were delivered & transitioned to operations for NPP. C3S transitioned to operations at the NOAA Satellite Operations Facility (NSOF) in Suitland Maryland in August 2007 and IDPS transitioned in July 2009. Both segments were involved with several compatibility tests with the NPP Satellite at the Ball Aerospace Technology Corporation (BATC) factory. The compatibility tests involved the spacecraft bus, the four sensors (VIIRS, ATMS, CrIS and OMPS), and both ground segments flowing data between the NSOF and BATC factory and flowing data from the polar ground station (Svalbard) over high-speed links back to the NSOF and the two IDP locations (NESDIS & AFWA). This presentation will describe the NPP/NPOESS ground architecture features & enhancements for the NPOESS era. These will include C3S-provided space-to-ground connectivity, reliable and secure data delivery and insight & oversight of the total operation. For NPOESS the ground architecture is extended to provide additional ground receptor sites to reduce data product delivery times to users and delivery of additional sensor data products from sensors similar to NPP and more NPOESS sensors. This architecture is also extended from two Centrals (NESDIS & AFWA) to two additional Centrals (FNMOC & NAVO). IDPS acts as a buffer minimizing changes in how users request and receive data products.

  19. Rule-based fuzzy vector median filters for 3D phase contrast MRI segmentation

    NASA Astrophysics Data System (ADS)

    Sundareswaran, Kartik S.; Frakes, David H.; Yoganathan, Ajit P.

    2008-02-01

    Recent technological advances have contributed to the advent of phase contrast magnetic resonance imaging (PCMRI) as standard practice in clinical environments. In particular, decreased scan times have made using the modality more feasible. PCMRI is now a common tool for flow quantification, and for more complex vector field analyses that target the early detection of problematic flow conditions. Segmentation is one component of this type of application that can impact the accuracy of the final product dramatically. Vascular segmentation, in general, is a long-standing problem that has received significant attention. Segmentation in the context of PCMRI data, however, has been explored less and can benefit from object-based image processing techniques that incorporate fluids specific information. Here we present a fuzzy rule-based adaptive vector median filtering (FAVMF) algorithm that in combination with active contour modeling facilitates high-quality PCMRI segmentation while mitigating the effects of noise. The FAVMF technique was tested on 111 synthetically generated PC MRI slices and on 15 patients with congenital heart disease. The results were compared to other multi-dimensional filters namely the adaptive vector median filter, the adaptive vector directional filter, and the scalar low pass filter commonly used in PC MRI applications. FAVMF significantly outperformed the standard filtering methods (p < 0.0001). Two conclusions can be drawn from these results: a) Filtering should be performed after vessel segmentation of PC MRI; b) Vector based filtering methods should be used instead of scalar techniques.

  20. A dual-center review of compressive osseointegration for fixation of massive endoprosthetics: 2- to 9-year followup.

    PubMed

    Calvert, George T; Cummings, Judd E; Bowles, Austin J; Jones, Kevin B; Wurtz, L Daniel; Randall, R Lor

    2014-03-01

    Aseptic failure of massive endoprostheses used in the reconstruction of major skeletal defects remains a major clinical problem. Fixation using compressive osseointegration was developed as an alternative to cemented and traditional press-fit fixation in an effort to decrease aseptic failure rates. The purpose of this study was to answer the following questions: (1) What is the survivorship of this technique at minimum 2-year followup? (2) Were patient demographic variables (age, sex) or anatomic location associated with implant failure? (3) Were there any prosthesis-related variables (eg, spindle size) associated with failure? (4) Was there a discernible learning curve associated with the use of the new device as defined by a difference in failure rate early in the series versus later on? The first 50 cases using compressive osseointegration fixation from two tertiary referral centers were retrospectively studied. Rates of component removal for any reason and for aseptic failure were calculated. Demographic, surgical, and oncologic factors were analyzed using regression analysis to assess for association with implant failure. Minimum followup was 2 years with a mean of 66 months. Median age at the time of surgery was 14.5 years. A total of 15 (30%) implants were removed for any reason. Of these revisions, seven (14%) were the result of aseptic failure. Five of the seven aseptic failures occurred at less than 1 year (average, 8.3 months), and none occurred beyond 17 months. With the limited numbers available, no demographic, surgical, or prosthesis-related factors correlated with failure. Most aseptic failures of compressive osseointegration occurred early. Longer followup is needed to determine if this technique is superior to other forms of fixation.

  1. Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell.

    PubMed

    Delanois, Ronald E; Gwam, Chukwuweike U; Mohamed, Nequesha; Khlopas, Anton; Chughtai, Morad; Malkani, Arthur L; Mont, Michael A

    2017-09-01

    We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes. Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits. The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up. At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Evaluating the Sensitivity of a Media-Fill Challenge Test Under Various Situations as a Reliable Method for Recommended Aseptic Technique Competency Assessment

    PubMed Central

    Moody, Colleen A.; Eckel, Stephen F.; Amerine, Lindsey B.

    2015-01-01

    Background: Microbial contamination of compounded medications is a serious concern within hospital pharmacies as it can lead to severe patient injury. The United States Pharmacopeia <797> mandates that pharmacy personnel responsible for preparing compounded sterile preparations must annually demonstrate competency in aseptic technique by performing a media-fill challenge test. Objective: The purpose of this study is to evaluate the sensitivity of a commonly used media-fill test through proper and improper compounding techniques. Methods: Two aseptically trained pharmacy technicians performed media-fill challenge testing by carrying out 5 separate manipulations 5 times each for a total of 25 trials. Sterile vials, syringes, and intravenous bags were prepared. The first manipulation followed best-practice aseptic technique and sterile compounding procedures. Each of the following 4 manipulations removed one aspect of best-practice aseptic technique. The prepared products were incubated at 20°C to 25°C. A positive result for microbial contamination is indicated by visible turbidity within the vials, syringes, and intravenous bags at the following check points: 24 hours, 72 hours, 7 days, 14 days, 21 days, and >30 days. Results: Twenty-five trials, each containing 10 distinct admixtures, resulted in a total of 250 compounded preparations. No single preparation showed signs of turbidity, sedimentation, or visible microbial growth at any of the 6 checkpoints yielding a 0% contamination rate. However, the positive controls inoculated with bacteria did have positive microbial growth results. Conclusion: A more sensitive test needs to be developed to provide assurances that all poor aseptic practices are detected in compounding personnel.

  3. Blood-CSF-barrier dysfunction is a marker for encephalitic involvement in patients with aseptic meningitis/meningoencephalitis.

    PubMed

    Hoyer, C; Eisele, P; Ebert, A D; Schneider, S; Gass, A; Fatar, M; Szabo, K; Alonso, A

    2016-11-01

    The term "aseptic meningitis" encompasses cases of meningitis with negative bacterial CSF culture, which predominantly are of viral etiology. While the clinical course is usually benign, complications such as encephalitic involvement resulting in a more severe clinical course may occur. Dysfunction of the blood-brain-barrier (BBB), which is a prerequisite for viral entry into the brain parenchyma, can be approximated using the CSF/serum albumin ratio, readily obtainable in routine CSF analysis. Analysis of CSF patterns in patients with aseptic meningitis/meningoencephalitis with a focus on BBB dysfunction as a marker for encephalitic involvement. Retrospective chart review of patients admitted to our hospital between 2004 and 2016 with a diagnosis of aseptic meningitis/meningoencephalitis. Patients with aseptic meningitis displaying clinical, MR-tomographic or electroencephalographic signs of encephalitic involvement were significantly older than patients without these features (47.4 vs. 35.5 yrs., p=0.002). In patients with meningoencephalitis, CSF analysis revealed a more severe disruption of BBB, approximated by the CSF/serum albumin ratio (p=0.002). Compromised BBB function correlated positively with length of hospitalization (p=0.007), indicative of a more severe clinical course. The number of CSF lymphocytes was found to predict the severity of the BBB disruption, which additionally was more frequently observed when herpesviridae were identified as infectious agents. We suggest that the CSF/serum albumin ratio as an estimate for BBB function should be attended to in the evaluation of patients with aseptic meningitis. Severe BBB dysfunction, older age and infection with herpesviridae appear to raise the risk for encephalitic involvement. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Mechanisms of Amplified Arteriogenesis in Collateral Artery Segments Exposed to Flow Direction Reversal

    PubMed Central

    Heuslein, Joshua L.; Meisner, Joshua K.; Li, Xuanyue; Song, Ji; Vincentelli, Helena; Leiphart, Ryan J.; Ames, Elizabeth G.; Price, Richard J.

    2015-01-01

    Objective Collateral arteriogenesis, the growth of existing arterial vessels to a larger diameter, is a fundamental adaptive response that is often critical for the perfusion and survival of tissues downstream of chronic arterial occlusion(s). Shear stress regulates arteriogenesis; however, the arteriogenic significance of flow direction reversal, occurring in numerous collateral artery segments after femoral artery ligation (FAL), is unknown. Our objective was to determine if flow direction reversal in collateral artery segments differentially regulates endothelial cell signaling and arteriogenesis. Approach and Results Collateral segments experiencing flow reversal after FAL in C57BL/6 mice exhibit increased pericollateral macrophage recruitment, amplified arteriogenesis (30% diameter and 2.8-fold conductance increases), and remarkably permanent (12 weeks post-FAL) remodeling. Genome-wide transcriptional analyses on HUVECs exposed to flow reversal conditions mimicking those occurring in-vivo yielded 10-fold more significantly regulated transcripts, as well as enhanced activation of upstream regulators (NFκB, VEGF, FGF2, TGFβ) and arteriogenic canonical pathways (PKA, PDE, MAPK). Augmented expression of key pro-arteriogenic molecules (KLF2, ICAM-1, eNOS) was also verified by qRT-PCR, leading us to test whether ICAM-1 and/or eNOS regulate amplified arteriogenesis in flow-reversed collateral segments in-vivo. Interestingly, enhanced pericollateral macrophage recruitment and amplified arteriogenesis was attenuated in flow-reversed collateral segments after FAL in ICAM-1−/− mice; however, eNOS−/− mice showed no such differences. Conclusions Flow reversal leads to a broad amplification of pro-arteriogenic endothelial signaling and a sustained ICAM-1-dependent augmentation of arteriogenesis. Further investigation of the endothelial mechanotransduction pathways activated by flow reversal may lead to more effective and durable therapeutic options for arterial occlusive diseases. PMID:26338297

  5. The radiation enhancement of the sterility assurance levels of sterile fluids — A case study

    NASA Astrophysics Data System (ADS)

    Plessis, T. A. Du.; Rosekilly, I. C.

    1995-02-01

    A study was undertaken to determine the effect of low-dose gamma irradiation on aseptically admixed total parenteral nutrition (TPN) solutions to which large inocula of three test bacterial species, recognised as common contaminants of these products, were added. Attainable SALs of TPN solutions containing test bacteria were subsequently calculated. Results showed that a minimum absorbed radiation dose as low as 1.5 kGy improved the SAL of aseptically prepared TPN solutions from a SAL of 10 -3 to a value of less than 10 -8 for the microorganisms investigated. No measurable changes in amino acid, electrolyte, glucose and lipid components of the solutions were detected up to a dose of 8.3 kGy. Practical experience applying this radiation treatment of TPNs rendered excellent results leading to the routine application of the process in South Africa.

  6. Aseptic meningitis outbreak caused by echovirus 30 in two regions in Bulgaria, May-August 2012.

    PubMed

    Mladenova, Z; Buttinelli, G; Dikova, A; Stoyanova, A; Troyancheva, M; Komitova, R; Stoycheva, M; Pekova, L; Parmakova, K; Fiore, L

    2014-10-01

    An aseptic meningitis outbreak emerged in two regions in Bulgaria in 2012 and echovirus 30 (E30) was established as the aetiological agent by cell culture isolation, serological test, and molecular-based techniques. A total of 157 patients with aseptic meningitis were investigated, of which 117 were confirmed as having E30-associated disease. Molecular analysis of 12 E30 isolates revealed 99-100% nucleotide and amino-acid identity between them and a close correlation with a Greek strain involved in an E30 outbreak in 2012. Children aged 5-14 years were mainly affected, which could reflect the absence of E30 epidemics in Bulgaria for a period of 11 years. The first case with E30 isolation (a 2-year-old patient from Plovdiv) was notified at the end of April 2012. This was most likely the index case, from which the spread of the virus started, causing sporadic cases first, which later led to an aseptic meningitis outbreak facilitated by person-to-person viral transmission.

  7. Object Segmentation from Motion Discontinuities and Temporal Occlusions–A Biologically Inspired Model

    PubMed Central

    Beck, Cornelia; Ognibeni, Thilo; Neumann, Heiko

    2008-01-01

    Background Optic flow is an important cue for object detection. Humans are able to perceive objects in a scene using only kinetic boundaries, and can perform the task even when other shape cues are not provided. These kinetic boundaries are characterized by the presence of motion discontinuities in a local neighbourhood. In addition, temporal occlusions appear along the boundaries as the object in front covers the background and the objects that are spatially behind it. Methodology/Principal Findings From a technical point of view, the detection of motion boundaries for segmentation based on optic flow is a difficult task. This is due to the problem that flow detected along such boundaries is generally not reliable. We propose a model derived from mechanisms found in visual areas V1, MT, and MSTl of human and primate cortex that achieves robust detection along motion boundaries. It includes two separate mechanisms for both the detection of motion discontinuities and of occlusion regions based on how neurons respond to spatial and temporal contrast, respectively. The mechanisms are embedded in a biologically inspired architecture that integrates information of different model components of the visual processing due to feedback connections. In particular, mutual interactions between the detection of motion discontinuities and temporal occlusions allow a considerable improvement of the kinetic boundary detection. Conclusions/Significance A new model is proposed that uses optic flow cues to detect motion discontinuities and object occlusion. We suggest that by combining these results for motion discontinuities and object occlusion, object segmentation within the model can be improved. This idea could also be applied in other models for object segmentation. In addition, we discuss how this model is related to neurophysiological findings. The model was successfully tested both with artificial and real sequences including self and object motion. PMID:19043613

  8. Etiologies and Management of Aseptic Meningitis in Patients Admitted to an Internal Medicine Department.

    PubMed

    Jarrin, Irène; Sellier, Pierre; Lopes, Amanda; Morgand, Marjolaine; Makovec, Tamara; Delcey, Veronique; Champion, Karine; Simoneau, Guy; Green, Andrew; Mouly, Stéphane; Bergmann, Jean-François; Lloret-Linares, Célia

    2016-01-01

    Several studies have focused on the clinical and biological characteristics of meningitis in order to distinguish between bacterial and viral meningitis in the emergency setting. However, little is known about the etiologies and outcomes of aseptic meningitis in patients admitted to Internal Medicine.The aim of the study is to describe the etiologies, characteristics, and outcomes of aseptic meningitis with or without encephalitis in adults admitted to an Internal Medicine Department.A retrospective cohort study was conducted in the Internal Medicine Department of the Lariboisière Hospital in Paris, France, from January 2009 to December 2011. Clinical and biological characteristics of aseptic meningitis were recorded. These included cerebrospinal fluid analysis, results of polymerase chain reaction testing, final diagnoses, and therapeutic management.The cohort included 180 patients fulfilling the criteria for aseptic meningitis with (n = 56) or without (n = 124) encephalitis. A definitive etiological diagnosis was established in 83 of the 180 cases. Of the cases with a definitive diagnosis, 73 were due to infectious agents, mainly enteroviruses, Herpes Simplex Virus 2, and Varicella Zoster Virus (43.4%, 16.8%, and 14.5% respectively). Inflammatory diseases were diagnosed in 7 cases. Among the 97 cases without definitive diagnoses, 26 (26.8%) remained free of treatment throughout their management whereas antiviral or antibiotic therapy was initiated in the emergency department for the remaining 71 patients. The treatment was discontinued in only 10 patients deemed to have viral meningitis upon admission to Internal Medicine.The prevalence of inflammatory diseases among patients admitted to internal medicine for aseptic meningitis is not rare (4% of overall aseptic meningitis). The PCR upon admission to the emergency department is obviously of major importance for the prompt optimization of therapy and management. However, meningitis due to viral agents or inflammatory diseases could also be distinguished according to several clinical and biological characteristics highlighted in this retrospective study. As recommendations are now available concerning the prescriptions of antiviral agents in viral meningitis, better therapeutic management is expected in the future.

  9. Etiologies and Management of Aseptic Meningitis in Patients Admitted to an Internal Medicine Department

    PubMed Central

    Jarrin, Irène; Sellier, Pierre; Lopes, Amanda; Morgand, Marjolaine; Makovec, Tamara; Delcey, Veronique; Champion, Karine; Simoneau, Guy; Green, Andrew; Mouly, Stéphane; Bergmann, Jean-François; Lloret-Linares, Célia

    2016-01-01

    Abstract Several studies have focused on the clinical and biological characteristics of meningitis in order to distinguish between bacterial and viral meningitis in the emergency setting. However, little is known about the etiologies and outcomes of aseptic meningitis in patients admitted to Internal Medicine. The aim of the study is to describe the etiologies, characteristics, and outcomes of aseptic meningitis with or without encephalitis in adults admitted to an Internal Medicine Department. A retrospective cohort study was conducted in the Internal Medicine Department of the Lariboisière Hospital in Paris, France, from January 2009 to December 2011. Clinical and biological characteristics of aseptic meningitis were recorded. These included cerebrospinal fluid analysis, results of polymerase chain reaction testing, final diagnoses, and therapeutic management. The cohort included 180 patients fulfilling the criteria for aseptic meningitis with (n = 56) or without (n = 124) encephalitis. A definitive etiological diagnosis was established in 83 of the 180 cases. Of the cases with a definitive diagnosis, 73 were due to infectious agents, mainly enteroviruses, Herpes Simplex Virus 2, and Varicella Zoster Virus (43.4%, 16.8%, and 14.5% respectively). Inflammatory diseases were diagnosed in 7 cases. Among the 97 cases without definitive diagnoses, 26 (26.8%) remained free of treatment throughout their management whereas antiviral or antibiotic therapy was initiated in the emergency department for the remaining 71 patients. The treatment was discontinued in only 10 patients deemed to have viral meningitis upon admission to Internal Medicine. The prevalence of inflammatory diseases among patients admitted to internal medicine for aseptic meningitis is not rare (4% of overall aseptic meningitis). The PCR upon admission to the emergency department is obviously of major importance for the prompt optimization of therapy and management. However, meningitis due to viral agents or inflammatory diseases could also be distinguished according to several clinical and biological characteristics highlighted in this retrospective study. As recommendations are now available concerning the prescriptions of antiviral agents in viral meningitis, better therapeutic management is expected in the future. PMID:26765411

  10. Specificity of Good Manufacturing Practice (GMP) for Biomedical Cell Products.

    PubMed

    Tulina, M A; Pyatigorskaya, N V

    2018-03-01

    The article describes special aspects of Good Manufacturing Practice (GMP) for biomedical cell products (BMCP) that imply high standards of aseptics throughout the entire productio process, strict requirements to donors and to the procedure of biomaterial isolation, guaranty of tracing BMCP products, defining processing procedures which allow to identify BMCP as minimally manipulated; continuous quality control and automation of the control process at all stages of manufacturing, which will ensure product release simultaneously with completion of technological operations.

  11. [A case of subacute necrotizing lymphadenitis with recurrent aseptic meningitis 11 years after the first episode].

    PubMed

    Itokawa, Kaori; Fukui, Miki; Nakazato, Yoshihiko; Yamamoto, Toshimasa; Tamura, Naotoshi; Sannohe, Seiya; Shimazu, Kunio

    2008-04-01

    We report a 29-year-old man with subacute necrotizing lymphadenitis (SNL) associated with recurrent aseptic meningitis following an 11-year remission period. In both episodes, headache and fever were followed by lymphadenopathy, with increased serum IgE level. Although pleocytosis in cerebrospinal fluid was confirmed at admission in the first episode, it appeared at one week after admission in the second episode. Administration of glucocorticoid was effective for treating meningitis. The present case suggests a pathomechanism for SNL that involves both an immunological background and an acute viral infection as triggers of exacerbation of aseptic meningitis.

  12. Bottom-simulating reflector variability at the Costa Rica subduction zone and corresponding heat flow model

    NASA Astrophysics Data System (ADS)

    Cavanaugh, S.; Bangs, N. L.; Hornbach, M. J.; McIntosh, K. D.

    2011-12-01

    We use 3D seismic reflection data acquired in April - May 2011 by the R/V Marcus G. Langseth to extract heat flow information using the bottom-simulating reflector across the Costa Rica convergent margin. These data are part of the CRISP Project, which will image the Middle America subduction zone in 3D. The survey was conducted in an area approximately 55 x 11 km, to the northwest of the Osa Peninsula, Costa Rica. For the analysis presented here, 3D seismic data were processed with Paradigm Focus software through post-stack time migration. The bottom-simulating reflector (BSR)-a reverse polarity reflection indicating the base of the gas hydrate phase boundary-is imaged very clearly in two regions within the slope-cover sediments in the accretionary prism. In deep water environments, the BSR acts as a temperature gauge revealing subsurface temperatures across the margin. We predict BSR depth using a true 3D diffusive heat flow model combined with IODP drilling data and compare results with actual BSR depth observations to determine anomalies in heat flow. Uniform heat flow in the region should result in a deepening BSR downslope toward the trench, however our initial results indicate the BSR shoals near the trench to its shallowest level below sea floor of approximately 96 m below the sea floor, suggesting elevated heat flow towards the toe. Landward, the BSR deepens to about 333 m below the sea floor indicating lower heat flow. Both BSR segments display a trend of deepening landward from the trench, however the depth below the sea floor is greater overall for the landward segment than the segment near the toe. We suggest two regimes with differing heat flow exist across the margin that likely represent two separate fluid flow regimes - one from recently accreted sediments near the prism toe and the other through the older materials making up the prism.

  13. [Aseptic cutaneous breast abscesses associated with ulcerative colitis].

    PubMed

    Sallé de Chou, C; Ortonne, N; Hivelin, M; Wolkenstein, P; Chosidow, O; Valeyrie-Allanore, L

    2016-02-01

    Inflammatory bowel diseases are associated with a broad range of cutaneous lesions. Herein we report the first case of aseptic skin abscesses associated with ulcerative colitis. Since March 2008, a 40-year-old woman presented with bilateral mammary abscesses, relapsing despite repeated antibiotic treatment. She was followed for ulcerative colitis diagnosed in 2011 by means of a rectal biopsy. Despite four surgical procedures, there was no improvement in her mammary abscesses and bilateral mastectomy was then proposed because of the persistent symptoms. Her general state of health remained stable. Clinically, there were bilateral inflammatory nodes with fistulae and pus. These lesions were extremely painful. Mild inflammatory syndrome was noted, but the immunological tests revealed nothing of note. Bacteriological, parasitological and mycological tests on biopsy specimens were negative. Histological examination of a surgical biopsy revealed lymphoplasmacytic infiltration of the dermis and subcutis with altered polymorphonuclear cells and epithelioid granuloma. The CT-scan showed no other remote lesions. The final diagnosis was cutaneous aseptic abscess syndrome associated with ulcerative colitis. Colchicine 1mg/day was initiated and resulted in regression of the skin lesions, with complete remission at one year of follow-up. Aseptic abscess syndrome must be considered in the event of recurrent aseptic cutaneous abscesses which may be associated with inflammatory bowel disease. Surgery should be avoided and treatment should be based on suitable drug therapy. Copyright © 2016. Published by Elsevier Masson SAS.

  14. In vivo endoscopic Doppler optical coherence tomography imaging of the colon

    PubMed Central

    Welge, Weston A.; Barton, Jennifer K.

    2017-01-01

    Background and Objective Colorectal cancer remains the second deadliest cancer in the United States. Several screening methods exist, however detection of small polyps remains a challenge. Optical coherence tomography has been demonstrated to be capable of detecting lesions as small as 1 mm in the mouse colon, but detection is based on measuring a doubling of the mucosa thickness. The colon microvasculature may be an attractive biomarker of early tumor development because tumor vessels are characterized by irregular structure and dysfunction. Our goal was to develop an endoscopic method of detecting and segmenting colon vessels using Doppler optical coherence tomography to enable future studies for improving early detection and development of novel chemopreventive agents. Method We conducted in vivo colon imaging in an azoxymethane (AOM)-treated mouse model of colorectal cancer using a miniature endoscope and a swept-source OCT system at 1040 nm with a 16 kHz sweep rate. We applied the Kasai autocorrelation algorithm to laterally oversampled OCT B-scans to resolve vascular flow in the mucosa and submucosa. Vessels were segmented by applying a series of image processing steps: (1) intensity thresholding, (2) two-dimensional matched filtering, and (3) histogram segmentation. Results We observed differences in the vessels sizes and spatial distribution in a mature adenoma compared to surrounding undiseased tissue and compared the results with histology. We also imaged flow in four young mice (2 AOM-treated and 2 control) showing no significant differences, which is expected so early after carcinogen exposure. We also present flow images of adenoma in a living mouse and a euthanized mouse to demonstrate that no flow is detected after euthanasia. Conclusion We present, to the best of our knowledge, the first Doppler OCT images of in vivo mouse colon collected with a fiber-based endoscope. We also describe a fast and robust image processing method for segmenting vessels in the colon. These results suggest that Doppler OCT is a promising imaging modality for vascular imaging in the colon that requires no exogenous contrast agents. PMID:27546786

  15. Physical inter-relationships between hydrothermal activity, faulting and magmatic processes at the center of a slow-spreading, magma-rich mid-ocean ridge segment: A case study of the Lucky Strike segment (MAR, 37°03'-37‧N)

    NASA Astrophysics Data System (ADS)

    Fontaine, F. J.; Cannat, M.; Escartin, J.; Crawford, W. C.; Singh, S. C.

    2012-12-01

    The modalities and efficiency of hydrothermal heat evacuation at mid-ocean ridges (25% of the global heat loss) are controlled by the lithosphere thermal and permeability structures for which we had robust constraints only for fast/intermediate spreading axis until the last past few years during which integrated geophysical, geological and geochemical studies focused on some hydrothermal sites at slow-spreading ridges. At the Lucky Strike vent field of the mid-atlantic ridge - a hydrothermal complex composed of high-temperature (maximum T=340°C), smoker-like vents and associated diffuse flow and extracting a few hundreds MW from the oceanic lithosphere - a seafloor observatory which installation started in 2005 highlights local interactions between hydrothermal, tectonic and magmatic processes. Detailed geophysical and geological investigations stress the role of the local axial fault system on localizing high- and low-temperature ventings around the faulted rim of a paleo lava lake. Microseismic studies bring constraints on the subseafloor hydrology and suggest an along-axis flow pattern, with a privileged recharge area located about a kilometer north off the active discharges. Seismic reflection studies image a central magma chamber fueling the hydrothermal sites and also reveal its along-axis depth variations likely influencing hydrothermal cell organization and flow focusing. Such linkages among hydrothermal dynamics, heat source and crustal permeability geometries usually lack quantitative constraints at mid-ocean ridges in general, and the Lucky Strike segment settings offers a unique opportunity to couple high-resolution geophysical data to hydrodynamic model. Here we develop a series of original two- and three-dimensional numerical and physical models of hydrothermal activity, tailored to this slow-spreading environment. Our results highlight physical linkages among magmatism, tectonics and crustal hydrology stressing the key role of faulting and magma chamber roof-topology in focusing fluid flow at the center of the Lucky Strike segment. They also help identifying some causes of variations in the modalities of hydrothermal heat extraction along the global ridge network.

  16. Optimization-based interactive segmentation interface for multiregion problems

    PubMed Central

    Baxter, John S. H.; Rajchl, Martin; Peters, Terry M.; Chen, Elvis C. S.

    2016-01-01

    Abstract. Interactive segmentation is becoming of increasing interest to the medical imaging community in that it combines the positive aspects of both manual and automated segmentation. However, general-purpose tools have been lacking in terms of segmenting multiple regions simultaneously with a high degree of coupling between groups of labels. Hierarchical max-flow segmentation has taken advantage of this coupling for individual applications, but until recently, these algorithms were constrained to a particular hierarchy and could not be considered general-purpose. In a generalized form, the hierarchy for any given segmentation problem is specified in run-time, allowing different hierarchies to be quickly explored. We present an interactive segmentation interface, which uses generalized hierarchical max-flow for optimization-based multiregion segmentation guided by user-defined seeds. Applications in cardiac and neonatal brain segmentation are given as example applications of its generality. PMID:27335892

  17. Implementation Strategies for Large-Scale Transport Simulations Using Time Domain Particle Tracking

    NASA Astrophysics Data System (ADS)

    Painter, S.; Cvetkovic, V.; Mancillas, J.; Selroos, J.

    2008-12-01

    Time domain particle tracking is an emerging alternative to the conventional random walk particle tracking algorithm. With time domain particle tracking, particles are moved from node to node on one-dimensional pathways defined by streamlines of the groundwater flow field or by discrete subsurface features. The time to complete each deterministic segment is sampled from residence time distributions that include the effects of advection, longitudinal dispersion, a variety of kinetically controlled retention (sorption) processes, linear transformation, and temporal changes in groundwater velocities and sorption parameters. The simulation results in a set of arrival times at a monitoring location that can be post-processed with a kernel method to construct mass discharge (breakthrough) versus time. Implementation strategies differ for discrete flow (fractured media) systems and continuous porous media systems. The implementation strategy also depends on the scale at which hydraulic property heterogeneity is represented in the supporting flow model. For flow models that explicitly represent discrete features (e.g., discrete fracture networks), the sampling of residence times along segments is conceptually straightforward. For continuous porous media, such sampling needs to be related to the Lagrangian velocity field. Analytical or semi-analytical methods may be used to approximate the Lagrangian segment velocity distributions in aquifers with low-to-moderate variability, thereby capturing transport effects of subgrid velocity variability. If variability in hydraulic properties is large, however, Lagrangian velocity distributions are difficult to characterize and numerical simulations are required; in particular, numerical simulations are likely to be required for estimating the velocity integral scale as a basis for advective segment distributions. Aquifers with evolving heterogeneity scales present additional challenges. Large-scale simulations of radionuclide transport at two potential repository sites for high-level radioactive waste will be used to demonstrate the potential of the method. The simulations considered approximately 1000 source locations, multiple radionuclides with contrasting sorption properties, and abrupt changes in groundwater velocity associated with future glacial scenarios. Transport pathways linking the source locations to the accessible environment were extracted from discrete feature flow models that include detailed representations of the repository construction (tunnels, shafts, and emplacement boreholes) embedded in stochastically generated fracture networks. Acknowledgment The authors are grateful to SwRI Advisory Committee for Research, the Swedish Nuclear Fuel and Waste Management Company, and Posiva Oy for financial support.

  18. Kotov works with samples from the Bioscience Experiment ASEPTIC during Joint Operations

    NASA Image and Video Library

    2010-02-19

    ISS022-E-068638 (18 Feb. 2010) --- Russian cosmonaut Oleg Kotov, Expedition 22 flight engineer, works with samples from the bioscience experiment ASEPTIC (BTKh-39) in the new Russian Glavboks-S (Glovebox) located in the Poisk Mini-Research Module 2 (MRM2) of the International Space Station.

  19. Kotov works with samples from the Bioscience Experiment ASEPTIC during Joint Operations

    NASA Image and Video Library

    2010-02-19

    ISS022-E-068640 (18 Feb. 2010) --- Russian cosmonaut Oleg Kotov, Expedition 22 flight engineer, works with samples from the bioscience experiment ASEPTIC (BTKh-39) in the new Russian Glavboks-S (Glovebox) located in the Poisk Mini-Research Module 2 (MRM2) of the International Space Station.

  20. Kotov works with samples from the Bioscience Experiment ASEPTIC during Joint Operations

    NASA Image and Video Library

    2010-02-19

    ISS022-E-068645 (18 Feb. 2010) --- Russian cosmonaut Oleg Kotov, Expedition 22 flight engineer, works with samples from the bioscience experiment ASEPTIC (BTKh-39) in the new Russian Glavboks-S (Glovebox) located in the Poisk Mini-Research Module 2 (MRM2) of the International Space Station.

  1. Stromal vascular fraction isolated from lipo-aspirates using an automated processing system: bench and bed analysis.

    PubMed

    Doi, Kentaro; Tanaka, Shinsuke; Iida, Hideo; Eto, Hitomi; Kato, Harunosuke; Aoi, Noriyuki; Kuno, Shinichiro; Hirohi, Toshitsugu; Yoshimura, Kotaro

    2013-11-01

    The heterogeneous stromal vascular fraction (SVF), containing adipose-derived stem/progenitor cells (ASCs), can be easily isolated through enzymatic digestion of aspirated adipose tissue. In clinical settings, however, strict control of technical procedures according to standard operating procedures and validation of cell-processing conditions are required. Therefore, we evaluated the efficiency and reliability of an automated system for SVF isolation from adipose tissue. SVF cells, freshly isolated using the automated procedure, showed comparable number and viability to those from manual isolation. Flow cytometric analysis confirmed an SVF cell composition profile similar to that after manual isolation. In addition, the ASC yield after 1 week in culture was also not significantly different between the two groups. Our clinical study, in which SVF cells isolated with the automated system were transplanted with aspirated fat tissue for soft tissue augmentation/reconstruction in 42 patients, showed satisfactory outcomes with no serious side-effects. Taken together, our results suggested that the automated isolation system is as reliable a method as manual isolation and may also be useful in clinical settings. Automated isolation is expected to enable cell-based clinical trials in small facilities with an aseptic room, without the necessity of a good manufacturing practice-level cell processing area. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Simultaneous determination of amino acids and carbohydrates in culture media of Clostridium thermocellum by valve-switching ion chromatography.

    PubMed

    Fa, Yun; Yang, Haiyan; Ji, Chengshuai; Cui, He; Zhu, Xinshu; Du, Juan; Gao, Jun

    2013-10-10

    An improved method for the simultaneous determination of 20 amino acids and 7 carbohydrates using one-valve switching after injection, ion chromatography, and integrated pulsed amperometric detection is proposed. The resolution of the amino acids and carbohydrates in the cation trap column was investigated. In addition, parameters including flow liquid type, flow rate, concentration, and valve-switch timing were optimized. The method is time-saving, effective, and accurate for the simultaneous separation of amino acids and carbohydrates, with a mean correlation coefficient of >0.99 and repeatability of 0.5-4.6% for eight replicates. The method was successfully applied in the analysis of amino acids and carbohydrates in aseptic media and in extracellular culture media of three phenotypes of Clostridium thermocellum. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haydary, J., E-mail: juma.haydary@stuba.sk; Susa, D.; Dudáš, J.

    Highlights: ► Pyrolysis of aseptic packages was carried out in a laboratory flow reactor. ► Distribution of tetrapak into the product yields was obtained. ► Composition of the pyrolysis products was estimated. ► Secondary thermal and catalytic decomposition of tars was studied. ► Two types of catalysts (dolomite and red clay marked AFRC) were used. - Abstract: Pyrolysis of aseptic packages (tetrapak cartons) in a laboratory apparatus using a flow screw type reactor and a secondary catalytic reactor for tar cracking was studied. The pyrolysis experiments were realized at temperatures ranging from 650 °C to 850 °C aimed at maximizingmore » of the amount of the gas product and reducing its tar content. Distribution of tetrapak into the product yields at different conditions was obtained. The presence of H{sub 2}, CO, CH{sub 4}, CO{sub 2} and light hydrocarbons, HCx, in the gas product was observed. The Aluminum foil was easily separated from the solid product. The rest part of char was characterized by proximate and elemental analysis and calorimetric measurements. The total organic carbon in the tar product was estimated by elemental analysis of tars. Two types of catalysts (dolomite and red clay marked AFRC) were used for catalytic thermal tar decomposition. Three series of experiments (without catalyst in a secondary cracking reactor, with dolomite and with AFRC) at temperatures of 650, 700, 750, 800 and 850 °C were carried out. Both types of catalysts have significantly affected the content of tars and other components in pyrolytic gases. The effect of catalyst on the tetrapack distribution into the product yield on the composition of gas and on the total organic carbon in the tar product is presented in this work.« less

  4. Lymphocytic Choriomeningitis Virus in Employees and Mice at Multipremises Feeder-Rodent Operation, United States, 2012

    PubMed Central

    Ströher, Ute; Edison, Laura; Albariño, César G.; Lovejoy, Jodi; Armeanu, Emilian; House, Jennifer; Cory, Denise; Horton, Clayton; Fowler, Kathy L.; Austin, Jessica; Poe, John; Humbaugh, Kraig E.; Guerrero, Lisa; Campbell, Shelley; Gibbons, Aridth; Reed, Zachary; Cannon, Deborah; Manning, Craig; Petersen, Brett; Metcalf, Douglas; Marsh, Bret; Nichol, Stuart T.; Rollin, Pierre E.

    2014-01-01

    We investigated the extent of lymphocytic choriomeningitis virus (LCMV) infection in employees and rodents at 3 commercial breeding facilities. Of 97 employees tested, 31 (32%) had IgM and/or IgG to LCMV, and aseptic meningitis was diagnosed in 4 employees. Of 1,820 rodents tested in 1 facility, 382 (21%) mice (Mus musculus) had detectable IgG, and 13 (0.7%) were positive by reverse transcription PCR; LCMV was isolated from 8. Rats (Rattus norvegicus) were not found to be infected. S-segment RNA sequence was similar to strains previously isolated in North America. Contact by wild mice with colony mice was the likely source for LCMV, and shipments of infected mice among facilities spread the infection. The breeding colonies were depopulated to prevent further human infections. Future outbreaks can be prevented with monitoring and management, and employees should be made aware of LCMV risks and prevention. PMID:24447605

  5. Aseptic meningitis and viral myelitis.

    PubMed

    Irani, David N

    2008-08-01

    Meningitis and myelitis represent common and very infrequent viral infections of the central nervous system, respectively. The number of cases of viral meningitis that occurs annually exceeds the total number of meningitis cases caused by all other etiologies combined. Focal central nervous system infections, such as occur in the spinal cord with viral myelitis, are much less common and may be confused with noninfectious disorders that cause acute flaccid paralysis. This article reviews some of the important clinical features, epidemiology, diagnostic approaches, and management strategies for patients with aseptic meningitis and viral myelitis. Particular focus is placed on the diseases caused by enteroviruses, which as a group account for most aseptic meningitis cases and many focal infections of the spinal cord.

  6. Automatic lesion boundary detection in dermoscopy images using gradient vector flow snakes

    PubMed Central

    Erkol, Bulent; Moss, Randy H.; Stanley, R. Joe; Stoecker, William V.; Hvatum, Erik

    2011-01-01

    Background Malignant melanoma has a good prognosis if treated early. Dermoscopy images of pigmented lesions are most commonly taken at × 10 magnification under lighting at a low angle of incidence while the skin is immersed in oil under a glass plate. Accurate skin lesion segmentation from the background skin is important because some of the features anticipated to be used for diagnosis deal with shape of the lesion and others deal with the color of the lesion compared with the color of the surrounding skin. Methods In this research, gradient vector flow (GVF) snakes are investigated to find the border of skin lesions in dermoscopy images. An automatic initialization method is introduced to make the skin lesion border determination process fully automated. Results Skin lesion segmentation results are presented for 70 benign and 30 melanoma skin lesion images for the GVF-based method and a color histogram analysis technique. The average errors obtained by the GVF-based method are lower for both the benign and melanoma image sets than for the color histogram analysis technique based on comparison with manually segmented lesions determined by a dermatologist. Conclusions The experimental results for the GVF-based method demonstrate promise as an automated technique for skin lesion segmentation in dermoscopy images. PMID:15691255

  7. Numerical investigation of flow and heat transfer in a novel configuration multi-tubular fixed bed reactor for propylene to acrolein process

    NASA Astrophysics Data System (ADS)

    Jiang, Bin; Hao, Li; Zhang, Luhong; Sun, Yongli; Xiao, Xiaoming

    2015-01-01

    In the present contribution, a numerical study of fluid flow and heat transfer performance in a pilot-scale multi-tubular fixed bed reactor for propylene to acrolein oxidation reaction is presented using computational fluid dynamics (CFD) method. Firstly, a two-dimensional CFD model is developed to simulate flow behaviors, catalytic oxidation reaction, heat and mass transfer adopting porous medium model on tube side to achieve the temperature distribution and investigate the effect of operation parameters on hot spot temperature. Secondly, based on the conclusions of tube-side, a novel configuration multi-tubular fixed-bed reactor comprising 790 tubes design with disk-and-doughnut baffles is proposed by comparing with segmental baffles reactor and their performance of fluid flow and heat transfer is analyzed to ensure the uniformity condition using molten salt as heat carrier medium on shell-side by three-dimensional CFD method. The results reveal that comprehensive performance of the reactor with disk-and-doughnut baffles is better than that of with segmental baffles. Finally, the effects of operating conditions to control the hot spots are investigated. The results show that the flow velocity range about 0.65 m/s is applicable and the co-current cooling system flow direction is better than counter-current flow to control the hottest temperature.

  8. [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis].

    PubMed

    Krüger, T; Alter, C; Reichel, H; Birke, A; Hein, W; Spielmann, R P

    1998-03-01

    There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. The small sclerotic interface is quite different in comparison to so called "Reactive Lines". In one case of aseptic loosening there was an interposition of soft tissue between prosthesis and bone in MRT and CT. CFRP inaugurates new diagnostic possibilities in aseptic loosening of hip prosthesis and in tumour surgery too.

  9. Molecular diagnosis of echovirus 30 as the etiological agent in an outbreak of aseptic meningitis in Panama: May-June 2008.

    PubMed

    Martinez, Alexander A; Castillo, Juan; Sanchez, Mirla C; Zaldivar, Yamitzel; Mendoza, Yaxelis; Tribaldos, Maribel; Acosta, Pablo; Smith, Rebecca E; Pascale, Juan Miguel

    2012-12-15

    Aseptic meningitis outbreaks are commonly caused by viral pathogens with enterovirus a common etiological agent. Between May and June of 2008, an outbreak of 173 cases of aseptic meningitis occurred in the Chiriqui Province of Panama. Molecular techniques were used to identify the etiological agent. Cerebrospinal fluid (CSF) samples from 75 patients were received at the Gorgas Memorial Institute for Health Studies.  RNA extraction and one-step RT-PCR were performed on each sample to determine the presence of enterovirus.  Thirty-four samples which were positive for enterovirus were subject to group-specific PCR, sequencing, and phylogenetic analysis to identify the etiological agent of the outbreak. The CSF of 58 subjects was found positive for the enterovirus family using RT-PCR. Thirty-four samples were found to belong to the enterovirus B group. Phylogenetic analysis of four successfully sequenced samples revealed echovirus 30 as the etiological agent. Echovirus 30 is reported as the likely cause of an outbreak of aseptic meningitis in Panama, the first since the 1980s.

  10. Herpes simplex virus type 2-associated recurrent aseptic meningitis (Mollaret's meningitis) with a recurrence after 11-year interval: a case report.

    PubMed

    Nakamura, Yoshitsugu; Nakajima, Hideto; Kano, Yosuke; Unoda, Kiichi; Ishida, Shimon; Kimura, Fumiharu

    2016-11-29

    A 55-year-old woman was diagnosed with aseptic meningitis at the age of 43 and 44. She developed sudden fever and headache, and she showed nuchal rigidity. Cerebrospinal fluid examination revealed pleocytosis (cell count 208/mm 3 ) and was positive for herpes simplex virus type 2 (HSV-2) DNA by PCR. Acyclovir was started on the first day of admission, and she was complete recovery. Preserved cerebrospinal fluid specimen from aseptic meningitis at the age of 44 was also positive for HSV-2 DNA by PCR. She was diagnosed with HSV-2 associated recurrent aseptic meningitis (Mollaret's meningitis) with a recurrence after 11-year interval. She repeatedly relapsed genital herpes after 44 years old and she was treated with valacyclovir whenever genital herpes relapses. But she showed no genital herpes at the onset of meningitis. Because HSV-2 is one of the most significant causes of recurrent meningitis, we would like to stress that HSV-2 infection and antiviral therapy should always be kept in mind for a recurrent meningitis case.

  11. Multiple pathways for woody plant establishment on floodplains at local to regional scales

    USGS Publications Warehouse

    Cooper, D.J.; Andersen, D.C.; Chimner, Rodney A.

    2003-01-01

    1. The structure and functioning of riverine ecosystems is dependent upon regional setting and the interplay of hydrologic regime and geomorphologic processes. We used a retrospective analysis to study recruitment along broad, alluvial valley segments (parks) and canyon segments of the unregulated Yampa River and the regulated Green River in the upper Colorado River basin, USA. We precisely aged 811 individuals of Populus deltoides ssp. wislizenii (native) and Tamarix ramosissima (exotic) from 182 wooded patches and determined the elevation and character of the germination surface for each. We used logistic regression to relate recruitment events (presence or absence of cohort) to five flow and two weather parameters.2. Woody plant establishment occurred via multiple pathways at patch, reach and segment scales. Recruitment occurred through establishment on (1) vertically accreting bars in the unregulated alluvial valley, (2) high alluvial floodplain surfaces during rare large flood events, (3) vertically accreting channel margin deposits in canyon pools and eddies, (4) vertically accreting intermittent/abandoned channels, (5) low elevation gravel bars and debris fans in canyons during multi-year droughts, and (6) bars and channels formed prior to flow regulation on the dammed river during controlled flood events.3. The Yampa River's peak flow was rarely included in models estimating the likelihood that recruitment would occur in any year. Flow variability and the interannual pattern of flows, rather than individual large floods, control most establishment.4. Regulation of the Green River flow since 1962 has had different effects on woody vegetation recruitment in canyons and valleys. The current regime mimics drought in a canyon setting, accelerating Tamarix invasion whereas in valleys the ongoing geomorphic adjustment of the channel, combined with reduced flow variability, has nearly eliminated Populus establishment.5. A single year's flow or a particular pattern of flows over a sequence of years, whether natural or man-made, produces different recruitment opportunities in alluvial and canyon reaches, in diverse landforms within a particular river reach, and for Populus and Tamarix. The design of flows to restore riparian ecosystems must consider these multiple pathways and adjust the seasonal timing, magnitude and interannual frequency of flows to match the desired outcome.

  12. Microbial Load in Septic and Aseptic Procedure Rooms.

    PubMed

    Harnoss, Julian-Camill; Assadian, Ojan; Diener, Markus Karl; Müller, Thomas; Baguhl, Romy; Dettenkofer, Markus; Scheerer, Lukas; Kohlmann, Thomas; Heidecke, Claus-Dieter; Gessner, Stephan; Büchler, Markus Wolfgang; Kramer, Axel

    2017-07-10

    Highly effective measures to prevent surgical wound infections have been established over the last two decades. We studied whether the strict separation of septic and aseptic procedure rooms is still necessary. In an exploratory, prospective observational study, the microbial concentration in an operating room without a room ventilating system (RVS) was analyzed during 16 septic and 14 aseptic operations with the aid of an air sampler (50 cm and 1 m from the operative field) and sedimentation plates (1 m from the operative field, and contact culture on the walls). The means and standard deviations of the microbial loads were compared with the aid of GEE models (generalized estimation equations). In the comparison of septic and aseptic operations, no relevant differences were found with respect to the overall microbial concentration in the room air (401.7 ± 176.3 versus 388.2 ± 178.3 CFU/m 3 ; p = 0.692 [CFU, colony-forming units]) or sedimentation 1 m from the operative field (45.3 ± 22.0 versus 48.7 ± 18.5 CFU/m 2 /min; p = 0.603) and on the walls (35.7 ± 43.7 versus 29.0 ± 49.4 CFU/m 2 /min; p = 0.685). The only relevant differences between the microbial spectra associated with the two types of procedure were a small amount of sedimentation of Escherichia coli and Enterococcus faecalis in septic operations, and of staphylococcus aureus and pseudomonas stutzeri in aseptic operations, up to 30 minutes after the end of the procedure. These data do not suggest that septic and aseptic procedure rooms need to be separated. In interpreting the findings, one should recall that the study was not planned as an equivalence or non-inferiority study. Wherever patient safety is concerned, high-level safety concepts should only be demoted to lower levels if new and convincing evidence becomes available.

  13. Molecular detection and genotyping of enteroviruses from CSF samples of patients with suspected sepsis-like illness and/or aseptic meningitis from 2012 to 2015 in West Bank, Palestine.

    PubMed

    Dumaidi, Kamal; Al-Jawabreh, Amer

    2017-01-01

    Human enteroviruses (HEVs) are the most frequently reported cause of aseptic meningitis with or without CSF pleocytosis in childhood. Rapid detection and genotype of HEVs is essential to determine the causative agent and variant causing sepsis-like illness and/or aseptic meningitis. To investigate the molecular epidemiology of enteroviruses (EVs) among patients with sepsis-like illness and/or aseptic meningitis admitted to three major hospitals in West Bank, Palestine from 2012 to 2015. During the study period, 356 CSF samples were collected from patients with sepsis-like illness and/or aseptic meningitis. Two RT-nested PCR assays targeting a partial part of 5'UTR for direct diagnosis and the VP1 region for genotyping by sequence analysis of the viral genome were used. HEV RNA was detected in 66 of 356 (18.5%) of CSF samples. Age distribution showed that 64% (42/66) were infants (<1 year), 18% were children between 1 and 5 years old, 12% were children between 5 and 10 years old, and 6% were more than 10 years old. Of the 66 EV cases, 12 were successfully genotyped. Five different EV genotypes were identified. All of them belonged to HEV-B species. The study showed that echovirus 6 genotype accounted for 42% of the sequenced cases. The HEV infections in the present study tended to show slight seasonal pattern with more cases occurring during spring and summer, yet still significant numbers were also reported in fall and winter seasons. HEV was isolated from a significant number of children with sepsis-like illness and/or aseptic meningitis. In addition, the molecular method utilized for direct diagnosis and genotyping of HEV from CSF revealed that more than one HEV type circulated in the West Bank, Palestine during the study period.

  14. Effect of age on the incidence of aseptic meningitis following immunization with monovalent mumps vaccine.

    PubMed

    Muta, Hiromi; Nagai, Takao; Ito, Yuhei; Ihara, Toshiaki; Nakayama, Tetsuo

    2015-11-09

    The purpose of this study was to determine the risk of aseptic meningitis after mumps vaccination in younger children compared with older children. This prospective cohort study included a total of 21,465 children under 18 years of age who had received the first dose of three of the Japanese mumps monovalent vaccine. We compared the cumulative incidence of aseptic meningitis for 30 days after vaccination among the following age groups: ≤ 1, 2, 3-4, and ≥ 5 years old. We also investigated the cumulative incidence of salivary gland swelling, a fever (≥ 38°C) lasting at least 3 days during the 10 to 25 days following immunization, vomiting of 3 times or more, headache, and seizure. A total of 10 aseptic meningitis, 551 salivary gland swelling, 844 fevers, 669 vomiting, 757 headaches, and 29 seizure cases were identified. The cumulative incidence of aseptic meningitis increased with age (0.016%, 0.021%, 0.066%, and 0.096%, respectively). Statistical significance was observed between children ≥ 3 years old and those < 3 years of age [0.078% vs. 0.018%, RR 4.35 (95% CI 1.05-18.2), p=0.04]. The cumulative incidence of salivary gland swelling also increased with age (1.8%, 3.0%, 3.5%, and 4.5%, respectively). For non-specific adverse events, the cumulative incidence of fever or seizure decreased with age. In contrast, the cumulative incidence of headache increased with age. The cumulative incidence of vomiting was similar among children ≤ 4 years of age; however, that in those children ≥ 5 years old was significantly lower. The first dose of mumps vaccine that is currently available for use in Japan may be administered in children less than 3 years of age in order to complicate a less aseptic meningitis after immunization. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Molecular detection and genotyping of enteroviruses from CSF samples of patients with suspected sepsis-like illness and/or aseptic meningitis from 2012 to 2015 in West Bank, Palestine

    PubMed Central

    Dumaidi, Kamal; Al-Jawabreh, Amer

    2017-01-01

    Background Human enteroviruses (HEVs) are the most frequently reported cause of aseptic meningitis with or without CSF pleocytosis in childhood. Rapid detection and genotype of HEVs is essential to determine the causative agent and variant causing sepsis-like illness and/or aseptic meningitis. Aim To investigate the molecular epidemiology of enteroviruses (EVs) among patients with sepsis-like illness and/or aseptic meningitis admitted to three major hospitals in West Bank, Palestine from 2012 to 2015. Methods During the study period, 356 CSF samples were collected from patients with sepsis-like illness and/or aseptic meningitis. Two RT-nested PCR assays targeting a partial part of 5'UTR for direct diagnosis and the VP1 region for genotyping by sequence analysis of the viral genome were used. Results HEV RNA was detected in 66 of 356 (18.5%) of CSF samples. Age distribution showed that 64% (42/66) were infants (<1 year), 18% were children between 1 and 5 years old, 12% were children between 5 and 10 years old, and 6% were more than 10 years old. Of the 66 EV cases, 12 were successfully genotyped. Five different EV genotypes were identified. All of them belonged to HEV-B species. The study showed that echovirus 6 genotype accounted for 42% of the sequenced cases. The HEV infections in the present study tended to show slight seasonal pattern with more cases occurring during spring and summer, yet still significant numbers were also reported in fall and winter seasons. Conclusion HEV was isolated from a significant number of children with sepsis-like illness and/or aseptic meningitis. In addition, the molecular method utilized for direct diagnosis and genotyping of HEV from CSF revealed that more than one HEV type circulated in the West Bank, Palestine during the study period. PMID:28225788

  16. Performance of aseptic technique during neuraxial analgesia for labor before and after the publication of international guidelines on aseptic technique

    PubMed Central

    2014-01-01

    Background Aseptic technique and handwashing have been shown to be important factors in perioperative bacterial transmission, however compliance often remains low despite guidelines and educational programs. Infectious complications of neuraxial (epidural and spinal) anesthesia are severe but fortunately rare. We conducted a survey to assess aseptic technique practices for neuraxial anesthesia in Israel before and after publication of international guidelines (which focused on handwashing, jewelry/watch removal and the wearing of a mask and cap). Methods The sampling frame was the general anesthesiology workforce in hospitals selected from each of the four medical faculties in Israel. Data was collected anonymously over one week in each hospital in two periods: April 2006 and September 2009. Most anesthesiologists received the questionnaires at departmental staff meetings and filled them out during these meetings; additionally, a local investigator approached anesthesiologists not present at these staff meetings individually. Primary endpoint questions were: handwashing, removal of wristwatch/jewelry, wearing mask, wearing hat/cap, wearing sterile gown; answering options were: "always", "usually", "rarely" or "never". Primary endpoint for analysis: respondents who both always wash their hands and always wear a mask ("handwash-mask composite") - "always" versus "any other response". We used logistic regression to perform the analysis. Time (2006, 2009) and hospital were included in the analysis as fixed effects. Results 135/160 (in 2006) and 127/164 (in 2009) anesthesiologists responded to the surveys; response rate 84% and 77% respectively. Respondents constituted 23% of the national anesthesiologist workforce. The main outcome "handwash-mask composite" was significantly increased after guideline publication (33% vs 58%; p = 0.0003). In addition, significant increases were seen for handwashing (37% vs 63%; p = 0.0004), wearing of mask (61% vs 78%; p < 0.0001), hat/cap (53% vs 76%; p = 0.0011) and wearing sterile gown (32% vs 51%; p < 0.0001). An apparent improvement in aseptic technique from 2006 to 2009 is noted across all hospitals and all physician groups. Conclusion Self-reported aseptic technique by Israeli anesthesiologists improved in the survey conducted after the publication of international guidelines. Although the before-after study design cannot prove a cause-effect relationship, it does show an association between the publication of international guidelines and significant improvement in self-reported aseptic technique. PMID:24661425

  17. Coupled Growth in Hypermonotectics

    NASA Technical Reports Server (NTRS)

    Andrews, J. Barry; Coriell, Sam R.

    2001-01-01

    The overall objective of this project is to obtain a fundamental understanding of the physics controlling solidification processes in immiscible alloy systems. The investigation involves both experimentation and the development of a model describing solidification in monotectic systems. The experimental segment was designed to first demonstrate that it is possible to obtain interface stability and steady state coupled growth in hypermonotectic alloys through microgravity processing. Microgravity results obtained to date have verified this possibility. Future flights will permit experimental determination of the limits of interface stability and the influence of alloy composition and growth rate on microstructure. The objectives of the modeling segment of the investigation include prediction of the limits of interface stability, modeling of convective flow due to residual acceleration, and the influence of surface tension driven flows at the solidification interface. The study of solidification processes in immiscible alloy systems is hindered by the inherent convective flow that occurs on Earth and by the possibility of sedimentation of the higher density immiscible liquid phase. It has been shown that processing using a high thermal gradient and a low growth rate can lead to a stable macroscopically planar growth front even in hypermonotectic alloys. Processing under these growth conditions can avoid constitutional supercooling and prevent the formation of the minor immiscible liquid phase in advance of the solidification front. However, the solute depleted boundary layer that forms in advance of the solidification front is almost always less dense than the liquid away from the solidification front. As a result, convective instability is expected. Ground based testing has indicated that convection is a major problem in these alloy systems and leads to gross compositional variations along the sample and difficulties maintaining interface stability. Sustained low gravity processing conditions are necessary in order to minimize these problems and obtain solidification conditions which approach steady state.

  18. A novel method for unsteady flow field segmentation based on stochastic similarity of direction

    NASA Astrophysics Data System (ADS)

    Omata, Noriyasu; Shirayama, Susumu

    2018-04-01

    Recent developments in fluid dynamics research have opened up the possibility for the detailed quantitative understanding of unsteady flow fields. However, the visualization techniques currently in use generally provide only qualitative insights. A method for dividing the flow field into physically relevant regions of interest can help researchers quantify unsteady fluid behaviors. Most methods at present compare the trajectories of virtual Lagrangian particles. The time-invariant features of an unsteady flow are also frequently of interest, but the Lagrangian specification only reveals time-variant features. To address these challenges, we propose a novel method for the time-invariant spatial segmentation of an unsteady flow field. This segmentation method does not require Lagrangian particle tracking but instead quantitatively compares the stochastic models of the direction of the flow at each observed point. The proposed method is validated with several clustering tests for 3D flows past a sphere. Results show that the proposed method reveals the time-invariant, physically relevant structures of an unsteady flow.

  19. Observation of current reversal in the scanning tunneling spectra of fullerene-like WS2 nanoparticles.

    PubMed

    Azulay, Doron; Kopnov, Frieda; Tenne, Reshef; Balberg, Isaac; Millo, Oded

    2006-04-01

    Current-voltage characteristics measured using STM on fullerene-like WS2 nanoparticles show zero-bias current and contain segments in which the tunneling current flows opposite to the applied bias voltage. In addition, negative differential conductance peaks emerge in these reversed current segments, and the characteristics are hysteretic with respect to the change in the voltage sweep direction. Such unusual features resemble those appearing in cyclic voltammograms, but are uniquely observed here in tunneling spectra measured in vacuum, as well as in ambient and dry atmosphere conditions. This behavior is attributed to tunneling-driven electrochemical processes.

  20. The integration methods of fuzzy fault mode and effect analysis and fault tree analysis for risk analysis of yogurt production

    NASA Astrophysics Data System (ADS)

    Aprilia, Ayu Rizky; Santoso, Imam; Ekasari, Dhita Murita

    2017-05-01

    Yogurt is a product based on milk, which has beneficial effects for health. The process for the production of yogurt is very susceptible to failure because it involves bacteria and fermentation. For an industry, the risks may cause harm and have a negative impact. In order for a product to be successful and profitable, it requires the analysis of risks that may occur during the production process. Risk analysis can identify the risks in detail and prevent as well as determine its handling, so that the risks can be minimized. Therefore, this study will analyze the risks of the production process with a case study in CV.XYZ. The method used in this research is the Fuzzy Failure Mode and Effect Analysis (fuzzy FMEA) and Fault Tree Analysis (FTA). The results showed that there are 6 risks from equipment variables, raw material variables, and process variables. Those risks include the critical risk, which is the risk of a lack of an aseptic process, more specifically if starter yogurt is damaged due to contamination by fungus or other bacteria and a lack of sanitation equipment. The results of quantitative analysis of FTA showed that the highest probability is the probability of the lack of an aseptic process, with a risk of 3.902%. The recommendations for improvement include establishing SOPs (Standard Operating Procedures), which include the process, workers, and environment, controlling the starter of yogurt and improving the production planning and sanitation equipment using hot water immersion.

  1. Real time MRI prostate segmentation based on wavelet multiscale products flow tracking.

    PubMed

    Flores-Tapia, Daniel; Venugopal, Niranjan; Thomas, Gabriel; McCurdy, Boyd; Ryner, Lawrence; Pistorius, Stephen

    2010-01-01

    Currently, prostate cancer is the third leading cause of cancer-related deaths among men in North America. As with many others types of cancer, early detection and treatment greatly increases the patient's chance of survival. Combined Magnetic Resonance Imaging and Spectroscopic Imaging (MRI/MRSI) techniques have became a reliable tool for early stage prostate cancer detection. Nevertheless, their performance is strongly affected by the determination of the region of interest (ROI) prior to data acquisition process. The process of executing prostate MRI/MRSI techniques can be significantly enhanced by segmenting the whole prostate. A novel method for segmentation of the prostate in MRI datasets is presented. This method exploits the different behavior presented by signal singularities and noise in the wavelet domain in order to accurately detect the borders around the prostate. The prostate contour is then traced by using a set of spatially variant rules that are based on prior knowledge about the general shape of the prostate. The proposed method yielded promising results when applied to clinical datasets.

  2. Current and temperature distributions in-situ acquired by electrode-segmentation along a microtubular solid oxide fuel cell operating with syngas

    NASA Astrophysics Data System (ADS)

    Aydın, Özgür; Nakajima, Hironori; Kitahara, Tatsumi

    2015-10-01

    Addressing the fuel distribution and endothermic cooling by the internal reforming, we have measured longitudinal current/temperature variations by ;Electrode-segmentation; in a microtubular solid oxide fuel cell operated with syngas (50% pre-reformed methane) and equivalent H2/N2 (100% conversion of syngas to H2) at three different flow rates. Regardless of the syngas flow rates, currents and temperatures show irregular fluctuations with varying amplitudes from upstream to downstream segment. Analysis of the fluctuations suggests that the methane steam reforming reaction is highly affected by the H2 partial pressure. Current-voltage curves plotted for the syngas and equivalent H2/N2 flow rates reveal that the fuel depletion is enhanced toward the downstream during the syngas operation, resulting in a larger performance degradation. All the segments exhibit temperature drops with the syngas flow compared with the equivalent H2/N2 flow due to the endothermic cooling by the methane steam reforming reaction. Despite the drops, the segment temperatures remain above the furnace temperature; besides, the maximum temperature difference along the cell diminishes. The MSR reaction rate does not consistently increase with the decreasing gas inlet velocity (increasing residence time on the catalyst); which we ascribe to the dominating impact of the local temperatures.

  3. Evolution of the Mothra Hydrothermal Field, Endeavour Segment of the Juan de Fuca Ridge

    NASA Astrophysics Data System (ADS)

    Glickson, D.; Kelley, D. S.; Delaney, J.

    2005-12-01

    The Mothra Hydrothermal Field (MHF) is a 600 m long, high-temperature hydrothermal field. It is located 2.7 km south of the Main Endeavour Field at the southern end of the central Endeavour Segment. Mothra is the most areally extensive field along the Endeavour Segment, composed of six active sulfide clusters that are 40-200 m apart. Each cluster contains rare black smokers (venting up to 319°C), numerous diffusely venting chimneys, and abundant extinct chimneys and sulfide talus. From north to south, these clusters include Cauldron, Twin Peaks, Faulty Towers, Crab Basin, Cuchalainn, and Stonehenge. As part of the Endeavour Integrated Study Site (ISS), the MHF is a site of intensive interdisciplinary studies focused on linkages among geology, geochemistry, fluid chemistry, seismology, and microbiology. Axial valley geology at MHF is structurally complex, consisting of lightly fissured flows that abut the walls and surround a core of extensively fissured, collapsed terrain. Fissure abundance and distribution indicates that tectonism has been the dominant process controlling growth of the axial graben. Past magmatic activity is shown by the 200 m long chain of collapse basins between Crab Basin and Stonehenge, which may have held at least ~7500 m3 of lava. Assuming a flow thickness of 0.5 m, this amount of lava could cover over half the valley floor during a single volcanic event. At a local scale, MHF clusters vary in size, activity, and underlying geology. They range in size from 400-1600 m2 and consist of isolated chimneys and/or coalesced cockscomb arrays atop ramps of sulfide talus. In the northern part of the field, Cauldron, Twin Peaks, Faulty Towers, and Crab Basin are located near the western valley wall, bounded by basalt talus and a combination of collapsed sheet flows, intermixed lobate and sulfide, disrupted terrain, and isolated pillow ridges. The southern clusters, Cuchalainn and Stonehenge, are associated with collapse basins in the central valley and bounded by extensive lobate flows and disrupted terrain. At all clusters, active chimneys stand within meters of extinct chimneys, suggesting that flow in the shallow subsurface is both complex and transient. 1-2 m high mounds of sulfide talus and broken chimneys indicate that focused flow has been concentrated at the clusters for long periods, while extinct sulfide deposits between clusters and in collapse basins demonstrate that flow conduits have been rerouted and/or clogged by mineral precipitation. Two subsurface processes are responsible for hydrothermal venting at the clusters: tapping of magmatic heat near the lava drainbacks and tectonic movement along the steeply dipping, inward-facing normal faults at the western wall boundary. The interplay between these processes and fluid flow is synthesized in an evolutionary model of hydrothermal development at Mothra.

  4. Automated detection and segmentation of follicles in 3D ultrasound for assisted reproduction

    NASA Astrophysics Data System (ADS)

    Narayan, Nikhil S.; Sivanandan, Srinivasan; Kudavelly, Srinivas; Patwardhan, Kedar A.; Ramaraju, G. A.

    2018-02-01

    Follicle quantification refers to the computation of the number and size of follicles in 3D ultrasound volumes of the ovary. This is one of the key factors in determining hormonal dosage during female infertility treatments. In this paper, we propose an automated algorithm to detect and segment follicles in 3D ultrasound volumes of the ovary for quantification. In a first of its kind attempt, we employ noise-robust phase symmetry feature maps as likelihood function to perform mean-shift based follicle center detection. Max-flow algorithm is used for segmentation and gray weighted distance transform is employed for post-processing the results. We have obtained state-of-the-art results with a true positive detection rate of >90% on 26 3D volumes with 323 follicles.

  5. Form, shape and function: segmented blood flow in the choriocapillaris

    PubMed Central

    Zouache, M. A.; Eames, I.; Klettner, C. A.; Luthert, P. J.

    2016-01-01

    The development of fluid transport systems was a key event in the evolution of animals and plants. While within vertebrates branched geometries predominate, the choriocapillaris, which is the microvascular bed that is responsible for the maintenance of the outer retina, has evolved a planar topology. Here we examine the flow and mass transfer properties associated with this unusual geometry. We show that as a result of the form of the choriocapillaris, the blood flow is decomposed into a tessellation of functional vascular segments of various shapes delineated by separation surfaces across which there is no flow, and in the vicinity of which the transport of passive substances is diffusion-limited. The shape of each functional segment is determined by the distribution of arterioles and venules and their respective relative flow rates. We also show that, remarkably, the mass exchange with the outer retina is a function of the shape of each functional segment. In addition to introducing a novel framework in which the structure and function of the metabolite delivery system to the outer retina may be investigated in health and disease, the present work provides a general characterisation of the flow and transfers in multipole Hele-Shaw configurations. PMID:27779198

  6. Large wood mobility processes in low-order Chilean river channels

    NASA Astrophysics Data System (ADS)

    Iroumé, Andrés; Mao, Luca; Andreoli, Andrea; Ulloa, Héctor; Ardiles, María Paz

    2015-01-01

    Large wood (LW) mobility was studied over several time periods in channel segments of four low-order mountain streams, southern Chile. All wood pieces found within the bankfull channels and on the streambanks extending into the channel with dimensions more than 10 cm in diameter and 1 m in length were measured and their position was referenced. Thirty six percent of measured wood pieces were tagged to investigate log mobility. All segments were first surveyed in summer and then after consecutive rainy winter periods. Annual LW mobility ranged between 0 and 28%. Eighty-four percent of the moved LW had diameters ≤ 40 cm and 92% had lengths ≤ 7 m. Large wood mobility was higher in periods when maximum water level (Hmax) exceeded channel bankfull depth (HBk) than in periods with flows less than HBk, but the difference was not statistically significant. Dimensions of moved LW showed no significant differences between periods with flows exceeding and with flows less than bankfull stage. Statistically significant relationships were found between annual LW mobility (%) and unit stream power (for Hmax) and Hmax/HBk. The mean diameter of transported wood pieces per period was significantly correlated with unit stream power for H15% and H50% (the level above which the flow remains for 15 and 50% of the time, respectively). These results contribute to an understanding of the complexity of LW mobilization processes in mountain streams and can be used to assess and prevent potential damage caused by LW mobilization during floods.

  7. Research on Segmentation Monitoring Control of IA-RWA Algorithm with Probe Flow

    NASA Astrophysics Data System (ADS)

    Ren, Danping; Guo, Kun; Yao, Qiuyan; Zhao, Jijun

    2018-04-01

    The impairment-aware routing and wavelength assignment algorithm with probe flow (P-IA-RWA) can make an accurate estimation for the transmission quality of the link when the connection request comes. But it also causes some problems. The probe flow data introduced in the P-IA-RWA algorithm can result in the competition for wavelength resources. In order to reduce the competition and the blocking probability of the network, a new P-IA-RWA algorithm with segmentation monitoring-control mechanism (SMC-P-IA-RWA) is proposed. The algorithm would reduce the holding time of network resources for the probe flow. It segments the candidate path suitably for the data transmitting. And the transmission quality of the probe flow sent by the source node will be monitored in the endpoint of each segment. The transmission quality of data can also be monitored, so as to make the appropriate treatment to avoid the unnecessary probe flow. The simulation results show that the proposed SMC-P-IA-RWA algorithm can effectively reduce the blocking probability. It brings a better solution to the competition for resources between the probe flow and the main data to be transferred. And it is more suitable for scheduling control in the large-scale network.

  8. Complete grain boundaries from incomplete EBSD maps: the influence of segmentation on grain size determinations

    NASA Astrophysics Data System (ADS)

    Heilbronner, Renée; Kilian, Ruediger

    2017-04-01

    Grain size analyses are carried out for a number of reasons, for example, the dynamically recrystallized grain size of quartz is used to assess the flow stresses during deformation. Typically a thin section or polished surface is used. If the expected grain size is large enough (10 µm or larger), the images can be obtained on a light microscope, if the grain size is smaller, the SEM is used. The grain boundaries are traced (the process is called segmentation and can be done manually or via image processing) and the size of the cross sectional areas (segments) is determined. From the resulting size distributions, 'the grain size' or 'average grain size', usually a mean diameter or similar, is derived. When carrying out such grain size analyses, a number of aspects are critical for the reproducibility of the result: the resolution of the imaging equipment (light microscope or SEM), the type of images that are used for segmentation (cross polarized, partial or full orientation images, CIP versus EBSD), the segmentation procedure (algorithm) itself, the quality of the segmentation and the mathematical definition and calculation of 'the average grain size'. The quality of the segmentation depends very strongly on the criteria that are used for identifying grain boundaries (for example, angles of misorientation versus shape considerations), on pre- and post-processing (filtering) and on the quality of the recorded images (most notably on the indexing ratio). In this contribution, we consider experimentally deformed Black Hills quartzite with dynamically re-crystallized grain sizes in the range of 2 - 15 µm. We compare two basic methods of segmentations of EBSD maps (orientation based versus shape based) and explore how the choice of methods influences the result of the grain size analysis. We also compare different measures for grain size (mean versus mode versus RMS, and 2D versus 3D) in order to determine which of the definitions of 'average grain size yields the most stable results.

  9. [Serotype distribution of enteroviruses isolated from paediatric cases prediagnosed as aseptic meningitis between 2001-2004 period].

    PubMed

    Ozkaya, Etem; Uysal, Gülnar; Atak, Tunca; Alkan, Mehmet

    2005-01-01

    Enteroviruses have major clinical and public health importance and are one of the leading causes of aseptic meningitis. There are many diseases with similar clinical symptoms and cerebrospinal fluid (CSF) findings of aseptic meningitis, thus virus isolation and identification is crucial for definitive diagnosis. Virological diagnosis is nonetheless important to distinguish between induced meningitis and other treatable causes of disease with a similar clinical picture. A total of 249 samples obtained from 246 cases (age range: 0-15 years), prediagnosed as aseptic meningitis, were sent to Virology Laboratory of Refik Saydam Hygiene Center. The patients were followed at Department of Pediatric Infectious Diseases in the Social Security Hospital, Ankara, Turkey, between 2001 and 2004. Stool (n: 180), CSF (n: 54) and throat swab (n: 15) samples have been inoculated to RD (rhabdomyosarcoma), Hep-2 (human epithelioma) and L20B (transgenic mice) cell lines, and followed up for the presence of cytopathic effects. A total of 95 enterovirus strains were isolated from 85 (34.6%) cases, and serotyped by using RIVM (National Institute of Public and the Environment, Nederlands) antisera with microneutralization method. As a result, the most frequently isolated types were found as echovirus type 30 (n: 24) and coxsackievirus type B (n: 19), which were most frequently isolated between July to October. This is the first report from Turkey for aseptic meningitis cases due to echovirus type 25 (n:3), 18 (n:2), 14 (n:1), 13 (n:4), 11 (n:6), 9 (n:1), 6 (n:9), 5 (n:1), 4 (n:1) and coxsackievirus type A9 (n:1).

  10. Analytical study on a two-dimensional plane of the off-design flow properties of tandem-bladed compressor stators

    NASA Technical Reports Server (NTRS)

    Sanger, N. L.

    1973-01-01

    The flow characteristics of several tandem bladed compressor stators were analytically evaluated over a range of inlet incidence angles. The ratios of rear-segment to front-segment chord and camber were varied. Results were also compared to the analytical performance of a reference solid blade section. All tandem blade sections exhibited lower calculated losses than the solid stator. But no one geometric configuration exhibited clearly superior characteristics. The front segment accepts the major effect of overall incidence angle change. Rear- to front-segment camber ratios of 4 and greater appeared to be limited by boundary-layer separation from the pressure surface of the rear segment.

  11. A comparative study of the incidence of aseptic meningitis in symptomatic natural mumps patients and monovalent mumps vaccine recipients in Japan.

    PubMed

    Nagai, Takao; Okafuji, Teruo; Miyazaki, Chiaki; Ito, Yuhei; Kamada, Makoto; Kumagai, Takuji; Yuri, Kenji; Sakiyama, Hiroshi; Miyata, Akiko; Ihara, Toshiaki; Ochiai, Hitoshi; Shimomura, Kunihisa; Suzuki, Eitaro; Torigoe, Sadayoshi; Igarashi, Masahiro; Kase, Tetsuo; Okuno, Yoshinobu; Nakayama, Tetsuo

    2007-03-30

    To compare the incidence of aseptic meningitis associated with symptomatic natural mumps infection and in mumps vaccine recipients, we conducted a prospective comparative study. Consecutive samples of 1051 children with mumps were enrolled by 10 pediatricians and 21,465 vaccine recipients by 143 pediatric primary care practitioners, from January 1, 2000 to January 1, 2003. Parents used a daily diary to record symptoms during the period of illness (15 days) or 30-day period following immunization. Mumps infection was confirmed by virus isolation and/or detection of mumps virus genome in salivary and CSF samples. The incidence of aseptic meningitis was 13/1051 (1.24%) in patients with symptomatic natural mumps infection and was estimated to be 0.7-1.1% of overall infection in considering asymptomatic infection, and 10/21,465 (0.05%) in vaccine recipients. Although aseptic meningitis is a clear side effect of the mumps vaccine, the incidence is considerably lower than among those with symptomatic natural infection. Our results provide an informative data for consideration to resume mumps vaccine as a part of routine immunization schedule for Japanese children.

  12. The Role of TLR and Chemokine in Wear Particle-Induced Aseptic Loosening

    PubMed Central

    Gu, Qiaoli; Shi, Qin; Yang, Huilin

    2012-01-01

    Wear particle-induced periprosthetic osteolysis remains the principal cause of aseptic loosening of orthopaedic implants. Monocytes/macrophages phagocytose wear particles and release cytokines that induce inflammatory response. This response promotes osteoclast differentiation and osteolysis. The precise mechanisms by which wear particles are recognized and induce the accumulation of inflammatory cells in the periprosthetic tissue have not been fully elucidated. Recent studies have shown that toll-like receptors (TLRs) contribute to the cellular interaction with wear particles. Wear particles are recognized by monocytes/macrophages through TLRs coupled with the adaptor protein MyD88. After the initial interaction, wear particles induce both local and systemic migration of monocytes/macrophages to the periprosthetic region. The cellular migration is mediated through chemokines including interleukin-8, macrophage chemotactic protein-1, and macrophage inhibitory protein-1 in the periprosthetic tissues. Interfering with chemokine-receptor axis can inhibit cellular migration and inflammatory response. This paper highlights recent advances in TLR, and chemokine participated in the pathogenesis of aseptic loosening. A comprehensive understanding of the recognition and migration mechanism is critical to the development of measures that prevent wear particle-induced aseptic loosening of orthopaedic implants. PMID:23193363

  13. Application of digital interferogram evaluation techniques to the measurement of 3-D flow fields

    NASA Technical Reports Server (NTRS)

    Becker, Friedhelm; Yu, Yung H.

    1987-01-01

    A system for digitally evaluating interferograms, based on an image processing system connected to a host computer, was implemented. The system supports one- and two-dimensional interferogram evaluations. Interferograms are digitized, enhanced, and then segmented. The fringe coordinates are extracted, and the fringes are represented as polygonal data structures. Fringe numbering and fringe interpolation modules are implemented. The system supports editing and interactive features, as well as graphic visualization. An application of the system to the evaluation of double exposure interferograms from the transonic flow field around a helicopter blade and the reconstruction of the three dimensional flow field is given.

  14. Femoral Component Varus Malposition is Associated with Tibial Aseptic Loosening After TKA.

    PubMed

    Lee, Bum-Sik; Cho, Hyun-Ik; Bin, Seong-Il; Kim, Jong-Min; Jo, Byeong-Kyu

    2018-02-01

    The notion that neutral alignment is mandatory to assure long-term durability after TKA has been based mostly on short-film studies. However, this is challenged by recent long-film studies. We conducted this long-film study to know (1) whether the risk of aseptic revision for nontraumatic reasons was greater among knees with greater than 3° varus or valgus (defined as "outliers") than those that were aligned within 3° of neutral on long-standing mechanical axis (hip to knee) radiographs; and (2) what the failure mechanisms were and whether the malalignment was femoral or tibial in origin, or both, among those in the outlier group. Between November 1998 and January 2009 we performed 1299 cemented, posterior cruciate ligament-substituting TKAs in 867 patients for primary osteoarthritis. We had inadequate long-standing radiographs to analyze postoperative alignment for 124 of those knees, and an additional 24 were excluded for prespecified reasons. Consequently, 1151 knees were enrolled in our study. Of these, 982 (85%) in 661 patients (620 women and 41 men) who had followup greater than 24 months were analyzed. The knees were divided according to whether the postoperative mechanical axis was neutral (0° ± 3°), varus (> 3°), or valgus (< -3°) alignment on long-standing radiographs. The survivorships free from aseptic revision for nontraumatic reasons were compared among groups. The mechanical femoral and the tibial component alignment (MFCA and MTCA, respectively) were investigated to know the origin of overall mechanical malalignment of the outlier knees. The mean duration of followup was 8 ± 4 years (range, 2-17 years). Thirty-five knees (4%) showed aseptic loosening at 7 ± 4 years (range, 0.1-14 years) and five (1%) showed polyethylene wear at 12 ± 1 years (range, 10-13 years). Tibial loosening (73%) was the most common reason for aseptic revision followed by femoral loosening (30%). Of this cohort, 687 (70%), 250 (25%), and 45 (5%) knees had overall mechanical neutral, varus, and valgus alignment, respectively. Factors associated with the risk of aseptic revision were identified by Cox regression. The varus outliers (but not the valgus outliers) failed more often than the neutral knees (10% [25 of 250] versus 2% [13 of 687]; odds ratio [OR], 5.8, 95% CI, 2.9-11.5; p < 0.001). Ten-year survivorship free from aseptic revision was lower among varus outliers than among knees with neutral alignment (87% [95% CI, 80%-93%] versus 98% [95% CI, 97%-99%]; p = 0.001). Femoral component varus malpositioning was the main origin of the varus outliers (MFCA = 4.2° ± 2.0°; MTCA = 0.9° ± 1.7°) and was a risk factor for aseptic revision compared with neutral femoral positioning (OR, 14.0; 95% CI, 1.9-105.6; p < 0.001). This long-film study corresponds to previous short-film studies for the notion that varus malalignment is associated with inferior long-term implant survivorship. Although aseptic loosening occurred most commonly on the tibial side, the primary origin of the overall varus malalignment was femoral component varus malpositioning. Aiming for neutral alignment in TKA still seems to be a reasonable strategy in clinical practice. Level III, therapeutic study.

  15. Cooling system for three hook ring segment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Christian X.; Eng, Darryl; Lee, Ching-Pang

    2014-08-26

    A triple hook ring segment including forward, midsection and aft mounting hooks for engagement with respective hangers formed on a ring segment carrier for supporting a ring segment panel, and defining a forward high pressure chamber and an aft low pressure chamber on opposing sides of the midsection mounting hook. An isolation plate is provided on the aft side of the midsection mounting hook to form an isolation chamber between the aft low pressure chamber and the ring segment panel. High pressure air is supplied to the forward chamber and flows to the isolation chamber through crossover passages in themore » midsection hook. The isolation chamber provides convection cooling air to an aft portion of the ring segment panel and enables a reduction of air pressure in the aft low pressure chamber to reduce leakage flow of cooling air from the ring segment.« less

  16. Isolating causal pathways between flow and fish in the regulated river hierarchy

    Treesearch

    Ryan McManamay; Donald J. Orth; Charles A. Dolloff; David C. Mathews

    2015-01-01

    Unregulated river systems are organized in a hierarchy in which large scale factors (i.e. landscape and segment scales) influence local habitats (i.e. reach, meso- and microhabitat scales), and both differentially exert selective pressures on biota. Dams, however, create discontinua in these processes and change the hierarchical structure. We examined the relative...

  17. Appraising the plasticity of the circle of Willis: a model of hemodynamic modulation in cerebral arteriovenous malformations.

    PubMed

    Chuang, Yu-Ming; Guo, Wanyuo; Lin, Ching-Po

    2010-01-01

    Cerebral arteriovenous malformations (AVMs) harbor a network of abnormal vasculatures, namely the nidus between arterial and venous components. The pressure gradient between these two components results in abnormal high-velocity arteriovenous shunts flowing through the nidus and alternate intracranial hemodynamics. This study hypothesizes that the flow patterns of the circle of Willis (CoW) are modulated by the alternation of intracranial hemodynamics occurring in cerebral AVMs. The flow patterns of the CoW before and after AVMs had been corrected and the arteriovenous shunts closed by radiosurgery were assessed to validate the hypothesis. Fifty patients (32 men and 18 women; mean age 35.8 +/- 4.2, range 23-52 years) with cerebral AVMs previously treated by radiosurgery were retrospectively investigated. This investigation used magnetic resonance angiography, performed prior to and after AVM surgery, to assess the CoW flow patterns. The CoW flow patterns in nearly half of the subjects (20/50, 40%) altered after the AVMs had been corrected. The alterations included: (1) decreased size or ceased flow patterns in the CoW vascular segment: ipsilateral A1 (n = 1) of the anterior cerebral artery (ACA), ipsilateral posterior communicating artery (PCoA) segment (n = 7), contralateral PCoA collateral (n = 4), bilateral PCoA (n = 2); (2) increased size or opening of the previous 'hypoplastic' segment of CoW: ipsilateral A1 of ACA (n = 1), contralateral PCoA (n = 2), bilateral PCoA (n = 1), and (3) biphasic alteration of the CoW: ceased ipsilateral PCoA segment and opening ipsilateral A1 of the ACA (n = 1), ceased ipsilateral PCoA and opening contralateral P1 of the posterior cerebral artery (n = 1). The plasticity of the flow patterns in the CoW are modulated by intracranial hemodynamics as shown by the AVM model. The calibers of CoW arterial segments are not a static feature. Willisian collateralization with recruitment of the CoW segment may cease, or hypoplastic segments may reopen after closing arteriovenous shunts of the AVM. (c) 2010 S. Karger AG, Basel.

  18. Morphological changes in the anterior segment of the Abyssinian cat eye with hereditary rod-cone degeneration.

    PubMed

    May, Chr Albrecht; Lütjen-Drecoll, Elke; Narfström, Kristina

    2005-10-01

    The purpose of this study was to investigate morphological changes of the anterior segment of the eye in Abyssinian cats with progressive rod-cone degeneration and to correlate them with blood flow data obtained in the same animals. Sections of the left eyes of six normal cats and of eight cats with different stages of hereditary retinal degeneration were prepared for transmission and scanning electron microscopy. Tangential and sagittal sections were also stained with antibodies against substance P, tyrosine hydroxylase, panneuronal marker PGP9.5, nitric oxide synthase, synaptophysin, and smooth muscle alpha-actin. In Abyssinian cats with hereditary rod-cone degeneration, significant changes were observed in the iris consisting of irregularities in the vascular wall of smaller arteries without changes in their innervation pattern. The ciliary processes were shorter than in normal cats, and their structure appeared more compact and retracted. Slight changes were also observed in the anterior part of the ciliary epithelium. The anterior chamber angle region did not appear to be affected. Clear morphological correlations to the physiological blood flow data were observed in the anterior eye segment, pointing not only to functional but also morphological vascular abnormalities in this animal model for retinitis pigmentosa.

  19. Accurate tracking of tumor volume change during radiotherapy by CT-CBCT registration with intensity correction

    NASA Astrophysics Data System (ADS)

    Park, Seyoun; Robinson, Adam; Quon, Harry; Kiess, Ana P.; Shen, Colette; Wong, John; Plishker, William; Shekhar, Raj; Lee, Junghoon

    2016-03-01

    In this paper, we propose a CT-CBCT registration method to accurately predict the tumor volume change based on daily cone-beam CTs (CBCTs) during radiotherapy. CBCT is commonly used to reduce patient setup error during radiotherapy, but its poor image quality impedes accurate monitoring of anatomical changes. Although physician's contours drawn on the planning CT can be automatically propagated to daily CBCTs by deformable image registration (DIR), artifacts in CBCT often cause undesirable errors. To improve the accuracy of the registration-based segmentation, we developed a DIR method that iteratively corrects CBCT intensities by local histogram matching. Three popular DIR algorithms (B-spline, demons, and optical flow) with the intensity correction were implemented on a graphics processing unit for efficient computation. We evaluated their performances on six head and neck (HN) cancer cases. For each case, four trained scientists manually contoured the nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial image registration software based on conventional mutual information (MI), VelocityAI (Varian Medical Systems Inc.). The volume differences (mean±std in cc) between the average of the manual segmentations and automatic segmentations are 3.70+/-2.30 (B-spline), 1.25+/-1.78 (demons), 0.93+/-1.14 (optical flow), and 4.39+/-3.86 (VelocityAI). The proposed method significantly reduced the estimation error by 9% (B-spline), 38% (demons), and 51% (optical flow) over the results using VelocityAI. Although demonstrated only on HN nodal GTVs, the results imply that the proposed method can produce improved segmentation of other critical structures over conventional methods.

  20. [Synovial fluid from aseptically failed total hip or knee arthroplasty is not toxic to osteoblasts].

    PubMed

    Gallo, J; Zdařilová, A; Rajnochová Svobodová, A; Ulrichová, J; Radová, L; Smižanský, M

    2010-10-01

    A failure of total hip or knee artroplasty is associated with an increased production of joint fluid. This contains wear particles and host cells and proteins, and is assumed to be involved in the pathogenesis of aseptic loosening and periprosthetic osteolysis. This study investigated the effect of synovial fluid from patients with aseptically failed joint prostheses on osteoblast cultures. Synovial fluid samples were obtained from patients with failed total joint prostheses (TJP; n=36) and from control patient groups (n = 16) involving cases without TJP and osteoarthritis, without TJP but with osteoarthritis, and with stable TJP. The samples were treated in the standard manner and then cultured with the SaOS-2 cell line which shows the characteristics and behaviour of osteoblasts. Each fluid sample was also examined for the content of proteins, cells and selected cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG detected by ELISA). We tested the hypothesis assuming that the fluids from failed joints would show higher cytotoxicity to osteoblast culture and we also expected higher levels of IL-1ß, TNF-α, IL-6, and RANKL in patients with TJP failure and/ or with more severe bone loss. The statistical methods used included the Kruskal-Wallis ANOVA and Mann-Whitney U test. The fluids from failed TJPs showed the highest RANKL and the lowest OPG levels resulting in the highest RANKL/OPG ratio. However, there was no evidence suggesting that the joint fluids from failed TJPs would be more toxic to osteoblast culture than the fluids from control groups. In addition, no correlation was found between the fluid levels of molecules promoting inflammation and osteoclastic activity and the extent of bone loss in the hip (in terms of Saleh's classification) or the knee (AORI classification). In fact, the fluids from failed TJPs had higher protein levels in comparison with the controls, but the difference was not significant. The finding of high RANKL levels and low OPG concentrations is in agreement with the theory of aseptic loosening and periprosthetic osteolysis. The other cytokines, particularly TNF-α and IL-1ß, were found in low levels. This can be explained by the stage of particle disease at which the samples were taken for ELISA analysis. It is probable that the level of signal molecules reflects osteolytic process activity and is therefore not constant. The reason for no correlation found between cytokine levels and the extent of bone loss may also lie in the use of therapeutic classifications of bone defects that is apparently less sensitive to the biological activity of aseptic loosening and/or periprosthetic osteolysis. Synovial fluids from failed total hip or knee joint prostheses are not toxic to osteoblast cultures. Cytotoxicity indicators and levels of pro-inflammatory and pro-osteoclastic cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG) do not correlate well with the extent of periprosthetic bone loss. Key words: total joint replacement, arthroplasty, aseptic loosening, periprosthetic osteolysis, joint fluid, SaOS-2 cell line, cytotoxicity, cytokines, RANKL, OPG.

  1. Teaching aseptic technique for central venous access under ultrasound guidance: a randomized trial comparing didactic training alone to didactic plus simulation-based training.

    PubMed

    Latif, Rana K; Bautista, Alexander F; Memon, Saima B; Smith, Elizabeth A; Wang, Chenxi; Wadhwa, Anupama; Carter, Mary B; Akca, Ozan

    2012-03-01

    Our goal was to determine whether simulation combined with didactic training improves sterile technique during ultrasound (US)-guided central venous catheter (CVC) insertion compared with didactic training alone among novices. We hypothesized that novices who receive combined didactic and simulation-based training would perform similarly to experienced residents in aseptic technique, knowledge, and perception of comfort during US-guided CVC insertion on a simulator. Seventy-two subjects were enrolled in a randomized, controlled trial of an educational intervention. Fifty-four novices were randomized into either the didactic group or the simulation combined with didactic group. Both groups received didactic training but the simulation combined with didactic group also received simulation-based CVC insertion training. Both groups were tested by demonstrating US-guided CVC insertion on a simulator. Aseptic technique was scored on 8 steps as "yes/no" and also using a 7-point Likert scale with 7 being "excellent technique" by a rater blinded to subject randomization. After initial testing, the didactic group was offered simulation-based training and retesting. Both groups also took a pre- and posttraining test of knowledge and rated their comfort with US and CVC insertion pre- and posttraining on a 5-point Likert scale. Subsequently, 18 experienced residents also took the test of knowledge, rated their comfort level, and were scored while performing aseptic US-guided CVC insertion using a simulator. The simulation combined with didactic group achieved a 167% (95% confidence interval [CI] 133%-167%) incremental increase in yes/no scores and 115% (CI 112%-127%) incremental increase in Likert scale ratings on aseptic technique compared with novices in the didactic group. Compared with experienced residents, simulation combined with didactic trained novices achieved an increase in aseptic scores with a 33.3% (CI 16.7%-50%) increase in yes/no ratings and a 20% (CI 13.3%-40%) increase in Likert scaled ratings, and scored 2.5-fold higher on the test of knowledge. There was a 3-fold increase in knowledge and 2-fold increase in comfort level among all novices (P < 0.001) after combined didactic and simulation-based training. Simulation combined with didactic training is superior to didactic training alone for acquisition of clinical skills such as US-guided CVC insertion. After combined didactic and simulation-based training, novices can outperform experienced residents in aseptic technique as well as in measurements of knowledge.

  2. Estimation of Blood Flow Rates in Large Microvascular Networks

    PubMed Central

    Fry, Brendan C.; Lee, Jack; Smith, Nicolas P.; Secomb, Timothy W.

    2012-01-01

    Objective Recent methods for imaging microvascular structures provide geometrical data on networks containing thousands of segments. Prediction of functional properties, such as solute transport, requires information on blood flow rates also, but experimental measurement of many individual flows is difficult. Here, a method is presented for estimating flow rates in a microvascular network based on incomplete information on the flows in the boundary segments that feed and drain the network. Methods With incomplete boundary data, the equations governing blood flow form an underdetermined linear system. An algorithm was developed that uses independent information about the distribution of wall shear stresses and pressures in microvessels to resolve this indeterminacy, by minimizing the deviation of pressures and wall shear stresses from target values. Results The algorithm was tested using previously obtained experimental flow data from four microvascular networks in the rat mesentery. With two or three prescribed boundary conditions, predicted flows showed relatively small errors in most segments and fewer than 10% incorrect flow directions on average. Conclusions The proposed method can be used to estimate flow rates in microvascular networks, based on incomplete boundary data and provides a basis for deducing functional properties of microvessel networks. PMID:22506980

  3. Automated breast segmentation in ultrasound computer tomography SAFT images

    NASA Astrophysics Data System (ADS)

    Hopp, T.; You, W.; Zapf, M.; Tan, W. Y.; Gemmeke, H.; Ruiter, N. V.

    2017-03-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging system for breast cancer diagnosis. An essential step before further processing is to remove the water background from the reconstructed images. In this paper we present a fully-automated image segmentation method based on three-dimensional active contours. The active contour method is extended by applying gradient vector flow and encoding the USCT aperture characteristics as additional weighting terms. A surface detection algorithm based on a ray model is developed to initialize the active contour, which is iteratively deformed to capture the breast outline in USCT reflection images. The evaluation with synthetic data showed that the method is able to cope with noisy images, and is not influenced by the position of the breast and the presence of scattering objects within the breast. The proposed method was applied to 14 in-vivo images resulting in an average surface deviation from a manual segmentation of 2.7 mm. We conclude that automated segmentation of USCT reflection images is feasible and produces results comparable to a manual segmentation. By applying the proposed method, reproducible segmentation results can be obtained without manual interaction by an expert.

  4. Numerical Simulation on the Induced Voltage Across the Coil Terminal by the Segmented Flow of Ferrofluid and Air-Layer.

    PubMed

    Lee, Won-Ho; Lee, Sangyoup; Lee, Jong-Chul

    2018-09-01

    Nanoparticles and nanofluids have been implemented in energy harvesting devices, and energy harvesting based on magnetic nanofluid flow was recently achieved by using a layer-built magnet and microbubble injection to induce a voltage on the order of 10-1 mV. However, this is not yet suitable for some commercial purpose. The air bubbles must be segmented in the base fluid, and the magnetic flux of the ferrofluids should change over time to increase the amount of electric voltage and current from energy harvesting. In this study, we proposed a novel technique to achieve segmented flow of the ferrofluids and the air layers. This segmented ferrofluid flow linear generator can increase the magnitude of the induced voltage from the energy harvesting system. In our experiments, a ferrofluid-filled capsule produced time-dependent changes in the magnetic flux through a multi-turn coil, and the induced voltage was generated on the order of about 101 mV at a low frequency of 2 Hz. A finite element analysis was used to describe the time-dependent change of the magnetic flux through the coil according to the motion of the segmented flow of the ferrofluid and the air-layer, and the induced voltage was generated to the order of 102 mV at a high frequency of 12.5 Hz.

  5. Exploratory Development of an Ultrafast-Curing Wound Dressing

    DTIC Science & Technology

    1988-11-30

    removed at will. 0 Control water vapor and oxygen exchange, thus maintaining a moist environment for rapid healing. * Gradually deliver broad-spectrum...removal without precipitating another bjeeding episode, (c) promotion of normal wound healing under moist , aseptic environment, and (d) prevention of...conditions, the field dressing is capable of maintaining the wound moist , but aseptic. And, as explained in the following paragraphs, it is ncm

  6. Rapid and sensitive detection of enteroviruses in specimens from patients with aseptic meningitis.

    PubMed Central

    Yerly, S; Gervaix, A; Simonet, V; Caflisch, M; Perrin, L; Wunderli, W

    1996-01-01

    A 5-h PCR assay (Amplicor enterovirus test) was compared with viral culture for the detection of enteroviruses in cerebrospinal fluid. Of the cerebrospinal fluid specimens collected during a summer outbreak of aseptic meningitis, 34% were positive by viral culture whereas 66% were positive by the Amplicor PCR, suggesting that this technique improves the diagnosis of enteroviral meningitis. PMID:8748304

  7. Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

    PubMed

    van der Voort, Paul; Pijls, Bart G; Nieuwenhuijse, Marc J; Jasper, Jorrit; Fiocco, Marta; Plevier, Josepha W M; Middeldorp, Saskia; Valstar, Edward R; Nelissen, Rob G H H

    2015-01-01

    Few studies have addressed the association between early migration of femoral stems and late aseptic revision in total hip arthroplasty. We performed a meta-regression analysis on 2 parallel systematic reviews and meta-analyses to determine the association between early migration and late aseptic revision of femoral stems. Of the 2 reviews, one covered early migration data obtained from radiostereometric analysis (RSA) studies and the other covered long-term aseptic revision rates obtained from survival studies with endpoint revision for aseptic loosening. Stems were stratified according to the design concept: cemented shape-closed, cemented force-closed, and uncemented. A weighted regression model was used to assess the association between early migration and late aseptic revision, and to correct for confounders. Thresholds for acceptable and unacceptable migration were determined in accordance with the national joint registries (≤ 5% revision at 10 years) and the NICE criteria (≤ 10% revision at 10 years). 24 studies (731 stems) were included in the RSA review and 56 studies (20,599 stems) were included in the survival analysis review. Combining both reviews for the 3 design concepts showed that for every 0.1-mm increase in 2-year subsidence, as measured with RSA, there was a 4% increase in revision rate for the shape-closed stem designs. This association remained after correction for age, sex, diagnosis, hospital type, continent, and study quality. The threshold for acceptable migration of shape-closed designs was defined at 0.15 mm; stems subsiding less than 0.15 mm in 2 years had revision rates of less than 5% at 10 years, while stems exceeding 0.15 mm subsidence had revision rates of more than 5%. There was a clinically relevant association between early subsidence of shape-closed femoral stems and late revision for aseptic loosening. This association can be used to assess the safety of shape-closed stem designs. The published research is not sufficient to allow us to make any conclusions regarding such an association for the force-closed and uncemented stems.

  8. Efficiency gain limits of the parallel segmented inlet and outlet flow concept in analytical liquid chromatography columns suffering from radial transcolumn packing density gradients.

    PubMed

    Broeckhoven, Ken; Desmet, Gert

    2012-10-05

    The maximal gain in efficiency that can be expected from the use of the segmented column end fittings that were recently introduced to alleviate the effect of transcolumn packing density gradients has been quantified and generalized using numerical computations of the band broadening process. It was found that, for an unretained compound in a column with a parabolic packing density gradient, the use of a segmented inlet or a segmented outlet allows to eliminate about 60-100% of the plate height contribution (H(tc)) originating from a parabolic transcolumn velocity gradient in a d(c)=4.6 mm column. In a d(c)=2.1 mm column, these percentages change from 10 to 100%. Using a combined segmented in- and outlet, H(tc) can be reduced by about 90-100% (d(c)=4.6 mm column) or 20-100% (d(c)=2.1 mm column). The strong variation of these gain percentages is due to fact that they depend very strongly on the column length and the flow rate. Dimensionless graphs have been established that allow to directly quantify the effect for each specific case. It was also found that, in agreement with one's physical intuition, trans-column velocity profiles that are more flat in the central region benefit more from the concept than sharp, parabolic-like profiles. The gain margins furthermore tend to become smaller with increasing retention and increasing diffusion coefficient. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Flow of two immiscible fluids in a periodically constricted tube: Transitions to stratified, segmented, churn, spray or segregated flow

    NASA Astrophysics Data System (ADS)

    Tsamopoulos, John; Fraggedakis, Dimitris; Dimakopoulos, Yiannis

    2015-11-01

    We study the flow of two immiscible, Newtonian fluids in a periodically constricted tube driven by a constant pressure gradient. Our Volume-of-Fluid algorithm is used to solve the governing equations. First the code is validated by comparing its predictions to previously reported results for stratified and pulsing flow. Then it is used to capture accurately all the significant topological changes that take place. Initially, the fluids have a core-annular arrangement, which is found to either remain the same or change to a different arrangement depending on the fluid properties, the pressure driving the flow or the flow geometry. The flow-patterns that appear are the core-annular, segmented, churn, spray and segregated flow. The predicted scalings near pinching of the core fluid concur with similarity predictions and earlier numerical results (Cohen et al. (1999)). Flow-pattern maps are constructed in terms of the Reynolds and Weber numbers. Our results provide deeper insights in the mechanism of the pattern transitions and are in agreement with previous studies on core-annular flow (Kouris & Tsamopoulos (2001 & 2002)), segmented flow (Lac & Sherwood (2009)) and churn flow (Bai et al. (1992)). GSRT of Greece through the program ``Excellence'' (Grant No. 1918, entitled ``FilCoMicrA'').

  10. Investigation of transonic flow over segmented slotted wind tunnel wall with mass transfer

    NASA Technical Reports Server (NTRS)

    Bhat, M. K.; Vakili, A. D.; Wu, J. M.

    1990-01-01

    The flowfield on a segmented multi-slotted wind tunnel wall was studied at transonic speeds by measurements in and near the wall layer using five port cone probes. The slotted wall flowfield was observed to be three-dimensional in nature for a relatively significant distance above the slot. The boundary layer characteristics measured on the single slotted wall were found to be very sensitive to the applied suction through the slot. The perturbation in the velocity components generated due to the flow through the slot decay rapidly in the transverse direction. A vortex-like flow existed on the single slotted wall for natural ventilation but diminished with increased suction flow rate. For flow on a segmented multi-slotted wall, the normal velocity component changes were found to be maximum for measurement points located between the segmented slots atop the active chamber. The lateral influence due to applied suction and blowing, through a compartment, exceeded only slightly that in the downstream direction. Limited upstream influence was observed. Influence coefficients were determined from the data in the least-square sense for blowing and suction applied through one and two compartments. This was found to be an adequate determination of the influence coefficients for the range of mass flows considered.

  11. D GIS for Flood Modelling in River Valleys

    NASA Astrophysics Data System (ADS)

    Tymkow, P.; Karpina, M.; Borkowski, A.

    2016-06-01

    The objective of this study is implementation of system architecture for collecting and analysing data as well as visualizing results for hydrodynamic modelling of flood flows in river valleys using remote sensing methods, tree-dimensional geometry of spatial objects and GPU multithread processing. The proposed solution includes: spatial data acquisition segment, data processing and transformation, mathematical modelling of flow phenomena and results visualization. Data acquisition segment was based on aerial laser scanning supplemented by images in visible range. Vector data creation was based on automatic and semiautomatic algorithms of DTM and 3D spatial features modelling. Algorithms for buildings and vegetation geometry modelling were proposed or adopted from literature. The implementation of the framework was designed as modular software using open specifications and partially reusing open source projects. The database structure for gathering and sharing vector data, including flood modelling results, was created using PostgreSQL. For the internal structure of feature classes of spatial objects in a database, the CityGML standard was used. For the hydrodynamic modelling the solutions of Navier-Stokes equations in two-dimensional version was implemented. Visualization of geospatial data and flow model results was transferred to the client side application. This gave the independence from server hardware platform. A real-world case in Poland, which is a part of Widawa River valley near Wroclaw city, was selected to demonstrate the applicability of proposed system.

  12. Structure and kinematics of segment-scale crustal accretion processes in Iceland and implications for analogous mid-ocean ridge systems

    NASA Astrophysics Data System (ADS)

    Siler, Drew Lorenz

    2011-12-01

    The sub-surface geologic structure of the crust is controlled by the magmatic and tectonic processes that construct the crust during plate spreading. As a result, geologic structure provides constraints on the processes that occur during plate spreading. The crust of the Skagi region of northern Iceland, where this study was focused, was accreted by magmatic construction to Iceland ˜7-10 Ma and subsequently glacially eroded, exhuming ˜1-3 km of structural relief. Continuous spreading-parallel and spreading-orthogonal mountain ranges expose the crust accreted at discrete spreading segments, the fundamental intervals upon which plate spreading and crustal accretion occur. As a result, Skagi is an ideal location to employ geologic structure analysis to study magmatic rifting processes. Within spreading segments structural patterns vary significantly between segment centers and distal fissure swarms. While segment centers are characterized by focused magmatic construction and km-scale sub-volcanic subsidence, fissure swarms are characterized by limited magmatic construction, minor sub-axial subsidence and lateral dike injection. Such along-strike variation indicates that both magma in the upper crust and gabbroic material in the lower crust must be redistributed along-strike within spreading segments during plate spreading. Material flow is directed from beneath segment centers towards distal fissure swarms. At the regional scale, each spreading segment is a structurally discrete interval of Iceland's Neovolcanic Zone. As a result of west-northwestward movement of Iceland relative to the Iceland hotspot, the rift zone axis has progressively relocated to the east-southeast with time, leaving a series of abandoned rift zones throughout western Iceland. A compilation of published K/Ar and 40Ar/39Ar age data and geologic data from across northern Iceland shows that rift relocation occurs via frequent (2-3 Ma), small-scale (˜20 km) rift propagations rather than rare, 100s of km 'rift jumps' as is conventional models suggest. The structure relationships we define in the Icelandic crust are similar to that of other magmatic rift systems including Mid-Ocean Ridges, continental rifts and ancient volcanic rift margins. As such, we suggest that many of the crustal accretion processes we have inferred from Icelandic data may be important in these analogous environments as well.

  13. Ultrafast synthesis of LTA nanozeolite using a two-phase segmented fluidic microreactor.

    PubMed

    Zhou, Jianhai; Jiang, Hao; Xu, Jian; Hu, Jun; Liu, Honglai; Hu, Ying

    2013-08-01

    Fast synthesis of nanosized zeolite is desirable for many industrial applications. An ultrafast synthesis of LTA nanozeolite by the organic-additive-free method in a two-phase segmented fluidic microreactor has been realized. The results reveal that the obtained LTA nanozeolites through microreactor are much smaller and higher crystallinity than those under similar conditions through conventional macroscale batch reactor. By investing various test conditions, such as the crystallization temperature, the flow rate, the microchannel length, and the aging time of gel solution, this two-phase segmented fluidic microreactor system enables us to develop an ultrafast method for nanozeolite production. Particularly, when using a microreactor with the microchannel length of 20 m, it only takes 10 min for the crystallization and no aging process to successfully produce the crystalline LTA nanozeolites at 95 degrees C.

  14. The thin blue line: a review and discussion of aseptic technique and postprocedural infections in rodents.

    PubMed

    Cooper, D M; McIver, R; Bianco, R

    2000-11-01

    A basic tenet of animal welfare philosophy is that pain and distress must be minimized whenever possible without interfering with the goals of the research. Aseptic technique during surgical procedures is essential to prevent pain and distress associated with post-procedural infections. However, many investigators have found that applying the aseptic techniques used for large animal and human surgery is not always practical when performing surgery on small rodents. Furthermore, the efficacy of some of these techniques for preventing post-procedural infections has been questioned. This review examines what is known about the development of postprocedural infections in animals and humans and the methods used to prevent them. Detection of postprocedural infections in rodents can be difficult unless objective measurements of physiologic indices are made. These measurements should be used experimentally to assess the relative benefits of various methods for preventing postprocedural infections. Measures of contamination, such as quantitative bacterial cultures, also can be used; however, they do not reliably predict infection rates. Much of the dogma about decontamination of skin and hair prior to surgery is not supported by valid experimental evidence. Hair removal may not be necessary. Alcohol may in fact be a better disinfectant than is often credited. Draping should be used when it contributes to the maintenance of the sterile field, but when it does not, modification of surgical technique may provide more protection from infection than the drape does. The contribution of surgical technique to the prevention of postprocedural infections is probably equal to that of aseptic technique. Further research needs to be done to assess various aseptic techniques for use in rodent surgery.

  15. Association between Apoptotis and CD4+/CD8+ T-Lymphocyte Ratio in Aseptic Loosening after Total Hip Replacement

    PubMed Central

    Landgraeber, Stefan; von Knoch, Marius; Löer, Franz; Brankamp, Jochen; Tsokos, Michael; Grabellus, Florian; Schmid, Kurt Werner; Totsch, Martin

    2009-01-01

    Particle-induced osteolysis is a major cause of aseptic loosening after total joint replacement. While the osteolytic cascade initiated by cytokine release from macrophages has been studied extensively, the involvement of T-lymphocytes in this context is controversial and has been addressed by only a few authors. In a former study we detected that the quantity of T-lymphocytes may be influenced by apoptosis in patients with aseptic loosening. In this study we intended to find out more details about the apoptosis-induced shifting of the T-cell number. We focused our interest on the CD4+ and CD8+ T-cells and their relative ratio. Caspase-3 cleaved was evaluated immunohistochemically to detect apoptotic T-cells in capsules and interface membranes from patients with aseptic hip implant loosening and a varying degree of caspase-3 cleaved expression in CD4+ and CD8+ T-lymphocytes was detected. Moreover, a relationship between the intensity of the apoptotic reactions and the radiological extent of osteolysis was observed. The number of CD4+ cells was decreased in the presence of strong apoptotic reactions, respectively extensive osteolysis, while CD8+ cells were affected to a much lower degree. Thus, the CD4+/CD8+ ratio changed from 1.0 in cases with only small areas of periprosthetic osteolysis and minimally intense apoptosis to 0.33 in cases with large areas of osteolysis. This may suggest a causal relationship between the apoptosis-induced shift in the CD4+/CD8+ ratio and the osteolysis respectively aseptic loosening. It is possible that these findings may lead to a new understanding of particle-induced osteolysis. PMID:19214244

  16. Correlation of quantitative histopathological morphology and quantitative radiological analysis during aseptic loosening of hip endoprostheses.

    PubMed

    Bertz, S; Kriegsmann, J; Eckardt, A; Delank, K-S; Drees, P; Hansen, T; Otto, M

    2006-01-01

    Aseptic hip prosthesis loosening is the most important long-term complication in total hip arthroplasty. Polyethylene (PE) wear is the dominant etiologic factor in aseptic loosening, which together with other factors induces mechanisms resulting in bone loss, and finally in implant loosening. The single-shot radiograph analysis (EBRA, abbreviation for the German term "Einzel-Bild-Röntgenanalyse") is a computerized method for early radiological prediction of aseptic loosening. In this study, EBRA parameters were correlated with histomorphological parameters of the periprosthetic membrane. Periprosthetic membranes obtained from 19 patients during revision surgery of loosened ABG I-type total hip pros-theses were analyzed histologically and morphometrically. The pre-existing EBRA parameters, the thickness of the PE debris lay-er and the dimension of inclination and anteversion, were compared with the density of macrophages and giant cells. Addi-tionally, the semiquantitatively determined density of lymphocytes, plasma cells, giant cells and the size of the necrotic areas were correlated with the EBRA results. All periprosthetic membranes were classified as debris-induced type membranes. We found a positive correlation between the number of giant cells and the thickness of the PE debris layer. There was no significant correlation between the number of macrophages or all semiquantitative parameters and EBRA parameters. The number of giant cells decreased with implant duration. The morphometrically measured number of foreign body giant cells more closely reflects the results of the EBRA. The semiquantitative estimation of giant cell density could not substitute for the morphometrical analysis. The density of macrophages, lymphocytes, plasma cells and the size of necrotic areas did not correlate with the EBRA parameters, indicating that there is no correlation with aseptic loosening.

  17. Formation and Elimination of Transform Faults on the Reykjanes Ridge

    NASA Astrophysics Data System (ADS)

    Martinez, Fernando; Hey, Richard

    2017-04-01

    The Reykjanes Ridge is a type-setting for examining processes that form and eliminate transform faults because it has undergone these events systematically within the Iceland gradient in hot-spot influence. A Paleogene change in plate motion led to the abrupt segmentation of the originally linear axis into a stair-step ridge-transform configuration. Its subsequent evolution diachronously and systematically eliminated the just-formed offsets re-establishing the original linear geometry of the ridge over the mantle, although now spreading obliquely. During segmented stages accreted crust was thinner and during unsegmented stages southward pointing V-shaped crustal ridges formed. Although mantle plume effects have been invoked to explain the changes in segmentation and crustal features, we propose that plate boundary processes can account for these changes [Martinez & Hey, EPSL, 2017]. Fragmentation of the axis was a mechanical effect of an abrupt change in plate opening direction, as observed in other areas, and did not require mantle plume temperature changes. Reassembly of the fragmented axis to its original linear configuration was controlled by a deep damp melting regime that persisted in a linear configuration following the abrupt change in opening direction. Whereas the shallow and stronger mantle of the dry melting regime broke up into a segmented plate boundary, the persistent deep linear damp melting regime guided reassembly of the ridge axis back to its original configuration by inducing asymmetric spreading of individual ridge segments. Effects of segmentation on mantle upwelling explain crustal thickness changes between segmented and unsegmented phases of spreading without mantle temperature changes. Buoyant upwelling instabilities propagate along the long linear deep melting regime driven by regional gradients in mantle properties away from Iceland. Once segmentation is eliminated, these propagating upwelling instabilities lead to crustal thickness variations forming the V-shaped ridges on the Reykjanes Ridge flanks, without requiring actual rapid radial mantle plume flow or temperature variations. Our study indicates that the Reykjanes Ridge can be used to study how plate boundary processes within a regional gradient in mantle properties lead to a range of effects on lithospheric segmentation, melt production and crustal accretion.

  18. TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S; Robinson, A; Kiess, A

    2015-06-15

    Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCTmore » intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.« less

  19. Image-based modeling of the flow transition from a Berea rock matrix to a propped fracture

    NASA Astrophysics Data System (ADS)

    Sanematsu, P.; Willson, C. S.; Thompson, K. E.

    2013-12-01

    In the past decade, new technologies and advances in horizontal hydraulic fracturing to extract oil and gas from tight rocks have raised questions regarding the physics of the flow and transport processes that occur during production. Many of the multi-dimensional details of flow from the rock matrix into the fracture and within the proppant-filled fracture are still unknown, which leads to unreliable well production estimations. In this work, we use x-ray computed micro tomography (XCT) to image 30/60 CarboEconoprop light weight ceramic proppant packed between berea sandstone cores (6 mm in diameter and ~2 mm in height) under 4000 psi (~28 MPa) loading stress. Image processing and segmentation of the 6 micron voxel resolution tomography dataset into solid and void space involved filtering with anisotropic diffusion (AD), segmentation using an indicator kriging (IK) algorithm, and removal of noise using a remove islands and holes program. Physically-representative pore network structures were generated from the XCT images, and a representative elementary volume (REV) was analyzed using both permeability and effective porosity convergence. Boundary conditions were introduced to mimic the flow patterns that occur when fluid moves from the matrix into the proppant-filled fracture and then downstream within the proppant-filled fracture. A smaller domain, containing Berea and proppants close to the interface, was meshed using an in-house unstructured meshing algorithm that allows different levels of refinement. Although most of this domain contains proppants, the Berea section accounted for the majority of the elements due to mesh refinement in this region of smaller pores. A finite element method (FEM) Stokes flow model was used to provide more detailed insights on the flow transition from rock matrix to fracture. Results using different pressure gradients are used to describe the flow transition from the Berea rock matrix to proppant-filled fracture.

  20. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    PubMed

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  1. Aseptic Meningitis and Viral Myelitis

    PubMed Central

    Irani, David N.

    2008-01-01

    SYNOPSIS Meningitis and myelitis represent common and very infrequent viral infections of the central nervous system (CNS), respectively. Indeed, the number of cases of viral meningitis that occurs annually exceeds the total number of meningitis cases caused by all other etiologies combined. Focal CNS infections, on the other hand, such as occur in the spinal cord with viral myelitis, are much less common and may be confused with non-infectious disorders that cause acute flaccid paralysis (AFP). This chapter will review some of the important clinical features, epidemiology, diagnostic approaches, and management strategies for patients with aseptic meningitis and viral myelitis. Particular focus will be placed on the diseases caused by enteroviruses (EVs), which as a group account for the vast majority of all aseptic meningitis cases as well as many focal infections of the spinal cord. PMID:18657719

  2. Modeling of the flow stress for AISI H13 Tool Steel during Hard Machining Processes

    NASA Astrophysics Data System (ADS)

    Umbrello, Domenico; Rizzuti, Stefania; Outeiro, José C.; Shivpuri, Rajiv

    2007-04-01

    In general, the flow stress models used in computer simulation of machining processes are a function of effective strain, effective strain rate and temperature developed during the cutting process. However, these models do not adequately describe the material behavior in hard machining, where a range of material hardness between 45 and 60 HRC are used. Thus, depending on the specific material hardness different material models must be used in modeling the cutting process. This paper describes the development of a hardness-based flow stress and fracture models for the AISI H13 tool steel, which can be applied for range of material hardness mentioned above. These models were implemented in a non-isothermal viscoplastic numerical model to simulate the machining process for AISI H13 with various hardness values and applying different cutting regime parameters. Predicted results are validated by comparing them with experimental results found in the literature. They are found to predict reasonably well the cutting forces as well as the change in chip morphology from continuous to segmented chip as the material hardness change.

  3. A Method for Optimizing Non-Axisymmetric Liners for Multimodal Sound Sources

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.; Parrott, T. L.; Sobieski, J.

    2002-01-01

    Central processor unit times and memory requirements for a commonly used solver are compared to that of a state-of-the-art, parallel, sparse solver. The sparse solver is then used in conjunction with three constrained optimization methodologies to assess the relative merits of non-axisymmetric versus axisymmetric liner concepts for improving liner acoustic suppression. This assessment is performed with a multimodal noise source (with equal mode amplitudes and phases) in a finite-length rectangular duct without flow. The sparse solver is found to reduce memory requirements by a factor of five and central processing time by a factor of eleven when compared with the commonly used solver. Results show that the optimum impedance of the uniform liner is dominated by the least attenuated mode, whose attenuation is maximized by the Cremer optimum impedance. An optimized, four-segmented liner with impedance segments in a checkerboard arrangement is found to be inferior to an optimized spanwise segmented liner. This optimized spanwise segmented liner is shown to attenuate substantially more sound than the optimized uniform liner and tends to be more effective at the higher frequencies. The most important result of this study is the discovery that when optimized, a spanwise segmented liner with two segments gives attenuations equal to or substantially greater than an optimized axially segmented liner with the same number of segments.

  4. Electron Beam Sterilization Does Not Have a Detrimental Effect on the Ability of Extracellular Matrix Scaffolds to Support In Vivo Ligament Healing

    PubMed Central

    Proffen, Benedikt L.; Perrone, Gabriel S.; Fleming, Braden C.; Sieker, Jakob T.; Kramer, Joshua; Hawes, Michael L.; Badger, Gary J.; Murray, Martha M.

    2015-01-01

    Purpose Extra-cellular matrix (ECM) scaffolds have been used to enhance anterior cruciate ligament (ACL) repair in large animal models. To translate this technology to clinical care, identifying a method, which effectively sterilizes the material without significantly impairing in vivo function, is desirable. Methods 16 Yorkshire pigs underwent ACL transection and were randomly assigned to bridge-enhanced ACL repair – primary suture repair of the ACL with addition of autologous blood soaked ECM scaffold - with either 1) an aseptically processed ECM scaffold, or 2) an electron beam irradiated ECM scaffold. Primary outcome measures included sterility of the scaffold and biomechanical properties of the scaffold itself and the repaired ligament at eight weeks after surgery. Results Scaffolds treated with 15kGy electron beam irradiation had no bacterial or fungal growth noted, while aseptically processed scaffolds had bacterial growth in all tested samples. The mean biomechanical properties of the scaffold and healing ligament were lower in the electron beam group; however, differences were not statistically significant. Conclusions Electron beam irradiation was able to effectively sterilize the scaffolds. In addition, this technique had only a minimal impact on the in vivo function of the scaffolds when used for ligament healing in the porcine model. PMID:25676876

  5. Voluminous lava flow from Axial Seamount's south rift constrains extension rate on northern Vance Segment

    NASA Astrophysics Data System (ADS)

    Le Saout, M.; Clague, D. A.; Paduan, J. B.

    2017-12-01

    Axial Seamount is characterized by a robust magma supply resulting from the interaction between the Cobb hotspot and the Juan de Fuca Ridge. During the last two decades, magmatic activity was focused within the summit caldera and upper and middle portions of the two rift zones, with eruptions in 1998, 2011, and 2015. However, the distal ends of both rift zones have experienced numerous eruptions in the past. The most voluminous flows are located near the extreme ends, greater than 40 kilometers from the caldera. Where Axial's South Rift Zone overlaps with the Vance Segment of the Juan de Fuca Ridge, the 2015 MBARI expedition mapped 16 km2 of the seafloor with our AUV, and collected 33 rocks and 33 sediment cores during two ROV dives. The data were used to confirm the boundaries of an extensive flow tentatively identified using modern ship based bathymetry. This flow is 18 km wide and 6 km long for a total surface area of 63 km2. The flow is modified by superficial ( 5 m deep) and deep (25 to 45 m deep) subsidence pits, with the deepest pits giving an indication of the minimum thickness of the flow. The maximum thickness of 100 m is measured at the margins of the flow. We thus estimate a volume between 2.5 and 6 km3, making this flow the most voluminous known on the global mid ocean ridge system. The minimum volume is equivalent to the present volume of the summit caldera. Radiocarbon ages of foraminifera from the basal sections of sediment cores suggest that this flow is 1000 years old. This flow travelled east and partially filled the axial valley of the adjacent Vance Segment. Since emplacement, this part of the flow has experienced deformation by fissures and faults aligned with the trend of the Vance Segment. The horizontal extension across these features allows us to estimate a local deformation rate of 3 cm/yr of tectonic extension on the northern end of Vance Segment during the last 1000 years.

  6. Statistical analysis of environmental monitoring data: does a worst case time for monitoring clean rooms exist?

    PubMed

    Cundell, A M; Bean, R; Massimore, L; Maier, C

    1998-01-01

    To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.

  7. [Clinical, epidemiological, and etiological studies of adult aseptic meningitis: a report of 12 cases of herpes simplex meningitis, and a comparison with cases of herpes simplex encephalitis].

    PubMed

    Himeno, Takahiro; Shiga, Yuji; Takeshima, Shinichi; Tachiyama, Keisuke; Kamimura, Teppei; Kono, Ryuhei; Takemaru, Makoto; Takeshita, Jun; Shimoe, Yutaka; Kuriyama, Masaru

    2018-01-26

    We treated 437 cases of adult aseptic meningitis and 12 cases (including 2 recurrent patients; age, 31.8 ± 8.9 years; 7 females) of herpes simplex meningitis from 2004 to 2016. The incidence rate of adult herpes simplex meningitis in the cases with aseptic meningitis was 2.7%. One patient was admitted during treatment of genital herpes, but no association was observed between genital herpes and herpes simplex meningitis in the other cases. The diagnoses were confirmed in all cases as the cerebrospinal fluid (CSF) was positive for herpes simplex virus (HSV)-DNA. For diagnosis confirmation, the DNA test was useful after 2-7 days following initial disease onset. Among other types of aseptic meningitis, the patients with herpes simplex meningitis showed relatively high white blood cell counts and relatively high CSF protein and high CSF cell counts. CSF cells showed mononuclear cell dominance from the initial stage of the disease. During same period, we also experienced 12 cases of herpes simplex encephalitis and 21 cases of non-hepatic acute limbic encephalitis. Notably, the patients with herpes simplex meningitis were younger and their CSF protein and cells counts were higher than those of the patients with herpes simplex encephalitis.

  8. Detection by PCR of Enteroviruses in Cerebrospinal Fluid during a Summer Outbreak of Aseptic Meningitis in Switzerland

    PubMed Central

    Gorgievski-Hrisoho, Meri; Schumacher, Jean-Daniel; Vilimonovic, Nevenka; Germann, Daniel; Matter, Lukas

    1998-01-01

    Enteroviruses (EV) are among the most common causes of aseptic meningitis. Standard diagnostic techniques are often too slow and lack sensitivity to be of clinical relevance. EV RNA can be detected within 5 h by a commercially available reverse transcription-PCR (RT-PCR) test kit. Cerebrospinal fluid (CSF) samples from 68 patients presenting with aseptic meningitis during a summer outbreak in Switzerland were examined in parallel with cell culture and commercial RT-PCR. RT-PCR was positive in all 16 CSF specimens positive by cell culture (100%). In addition, 42 of 52 (80%) CSF samples negative by cell culture were PCR positive. In 26 of these 42 (62%) patients, viral culture from other sites (throat swab or stool) was also positive. The CSF virus culture took 3 to 7 days to become positive. Echovirus 30 was the type most often isolated in this outbreak. The sensitivity of CSF RT-PCR based on clinical diagnosis during this aseptic meningitis outbreak in patients with negative bacterial culture results was 85%, i.e., considerably higher than the sensitivity of CSF virus culture (24%). We conclude that this commercial RT-PCR assay allows a positive diagnosis with minimal delay and may thus influence clinical decisions. PMID:9705364

  9. Aseptic and Bacterial Meningitis: Evaluation, Treatment, and Prevention.

    PubMed

    Mount, Hillary R; Boyle, Sean D

    2017-09-01

    The etiologies of meningitis range in severity from benign and self-limited to life-threatening with potentially severe morbidity. Bacterial meningitis is a medical emergency that requires prompt recognition and treatment. Mortality remains high despite the introduction of vaccinations for common pathogens that have reduced the incidence of meningitis worldwide. Aseptic meningitis is the most common form of meningitis with an annual incidence of 7.6 per 100,000 adults. Most cases of aseptic meningitis are viral and require supportive care. Viral meningitis is generally self-limited with a good prognosis. Examination maneuvers such as Kernig sign or Brudzinski sign may not be useful to differentiate bacterial from aseptic meningitis because of variable sensitivity and specificity. Because clinical findings are also unreliable, the diagnosis relies on the examination of cerebrospinal fluid obtained from lumbar puncture. Delayed initiation of antibiotics can worsen mortality. Treatment should be started promptly in cases where transfer, imaging, or lumbar puncture may slow a definitive diagnosis. Empiric antibiotics should be directed toward the most likely pathogens and should be adjusted by patient age and risk factors. Dexamethasone should be administered to children and adults with suspected bacterial meningitis before or at the time of initiation of antibiotics. Vaccination against the most common pathogens that cause bacterial meningitis is recommended. Chemoprophylaxis of close contacts is helpful in preventing additional infections.

  10. Investigation of Roadway Geometric and Traffic Flow Factors for Vehicle Crashes Using Spatiotemporal Interaction

    NASA Astrophysics Data System (ADS)

    Gill, G.; Sakrani, T.; Cheng, W.; Zhou, J.

    2017-09-01

    Traffic safety is a major concern in the transportation industry due to immense monetary and emotional burden caused by crashes of various severity levels, especially the injury and fatality ones. To reduce such crashes on all public roads, the safety management processes are commonly implemented which include network screening, problem diagnosis, countermeasure identification, and project prioritization. The selection of countermeasures for potential mitigation of crashes is governed by the influential factors which impact roadway crashes. Crash prediction model is the tool widely adopted by safety practitioners or researchers to link various influential factors to crash occurrences. Many different approaches have been used in the past studies to develop better fitting models which also exhibit prediction accuracy. In this study, a crash prediction model is developed to investigate the vehicular crashes occurring at roadway segments. The spatial and temporal nature of crash data is exploited to form a spatiotemporal model which accounts for the different types of heterogeneities among crash data and geometric or traffic flow variables. This study utilizes the Poisson lognormal model with random effects, which can accommodate the yearly variations in explanatory variables and the spatial correlations among segments. The dependency of different factors linked with roadway geometric, traffic flow, and road surface type on vehicular crashes occurring at segments was established as the width of lanes, posted speed limit, nature of pavement, and AADT were found to be correlated with vehicle crashes.

  11. Quantitative characterization of the carbon/carbon composites components based on video of polarized light microscope.

    PubMed

    Li, Yixian; Qi, Lehua; Song, Yongshan; Chao, Xujiang

    2017-06-01

    The components of carbon/carbon (C/C) composites have significant influence on the thermal and mechanical properties, so a quantitative characterization of component is necessary to study the microstructure of C/C composites, and further to improve the macroscopic properties of C/C composites. Considering the extinction crosses of the pyrocarbon matrix have significant moving features, the polarized light microscope (PLM) video is used to characterize C/C composites quantitatively because it contains sufficiently dynamic and structure information. Then the optical flow method is introduced to compute the optical flow field between the adjacent frames, and segment the components of C/C composites from PLM image by image processing. Meanwhile the matrix with different textures is re-segmented by the length difference of motion vectors, and then the component fraction of each component and extinction angle of pyrocarbon matrix are calculated directly. Finally, the C/C composites are successfully characterized from three aspects of carbon fiber, pyrocarbon, and pores by a series of image processing operators based on PLM video, and the errors of component fractions are less than 15%. © 2017 Wiley Periodicals, Inc.

  12. Exploring Population Admixture Dynamics via Empirical and Simulated Genome-wide Distribution of Ancestral Chromosomal Segments

    PubMed Central

    Jin, Wenfei; Wang, Sijia; Wang, Haifeng; Jin, Li; Xu, Shuhua

    2012-01-01

    The processes of genetic admixture determine the haplotype structure and linkage disequilibrium patterns of the admixed population, which is important for medical and evolutionary studies. However, most previous studies do not consider the inherent complexity of admixture processes. Here we proposed two approaches to explore population admixture dynamics, and we demonstrated, by analyzing genome-wide empirical and simulated data, that the approach based on the distribution of chromosomal segments of distinct ancestry (CSDAs) was more powerful than that based on the distribution of individual ancestry proportions. Analysis of 1,890 African Americans showed that a continuous gene flow model, in which the African American population continuously received gene flow from European populations over about 14 generations, best explained the admixture dynamics of African Americans among several putative models. Interestingly, we observed that some African Americans had much more European ancestry than the simulated samples, indicating substructures of local ancestries in African Americans that could have been caused by individuals from some particular lineages having repeatedly admixed with people of European ancestry. In contrast, the admixture dynamics of Mexicans could be explained by a gradual admixture model in which the Mexican population continuously received gene flow from both European and Amerindian populations over about 24 generations. Our results also indicated that recent gene flows from Sub-Saharan Africans have contributed to the gene pool of Middle Eastern populations such as Mozabite, Bedouin, and Palestinian. In summary, this study not only provides approaches to explore population admixture dynamics, but also advances our understanding on population history of African Americans, Mexicans, and Middle Eastern populations. PMID:23103229

  13. Structure and Neotectonics of the Southern Chile Forearc 35°S - 40°S

    NASA Astrophysics Data System (ADS)

    Geersen, Jacob; Völker, David; Weinrebe, Wilhelm; Krastel-Gudegast, Sebastian; Behrmann, Jan H.

    2010-05-01

    The Southern Chile Forearc exhibits an extreme level of neotectonic deformation. On-land studies have documented a pronounced segmentation in the region 36°S - 41°S. However, information on the seaward continuation of the individual segments towards the Chile Trench is rare, as direct observations end at the coastline and are replaced by a less dense set of marine geophysical data. In this study we use swath bathymetric data combined with high and low-frequency reflection seismic data as well as results from heat-flow measurements to: (A) map and identify active deformation structures and investigate their spatial distribution, and (B) analyse the factors controlling segmentation along the Southern Chile Forearc. Considering the region 35°S to 40°S we found evidence for a division into four major segments; Concepcion North, Concepcion South, Nahuelbuta, and Tolten (from North to South). Within all four segments, the lower continental slope is dissected by distinct margin-parallel thrust ridges overlying active landward-dipping thrust faults, indicating the presence of an active accretionary prism. The middle and upper slope, however, shows major differences between the four segments. The Concepcion North Segment is dominated by a large margin-parallel thrust ridge. The Concepcion South Segment shows large up to 600 m high north-south aligned normal fault scarps highlighting east-west extension. The change from thrust to normal faulting domains is accompanied by a drastic decrease in surface heat-flow by a factor of up to four. Further south in the Nahuelbuta Segment, east-west trending active thrust ridges indicate north-south compression of this part of the forearc. Shortening in this segment is not only limited to the middle and upper slope, but includes the entire marine forearc and occurs perpendicular to the direction of plate convergence. In the southernmost Tolten Segment the middle and upper continental slope shows no signs of compressive or extensional deformation. For the factors controlling segmentation our data suggest that when considering the whole forearc variations in the overriding plate such as the position of continental fault zones are responsible for the large scale tectonic segmentation. The east-west oriented shortening structures in the Nahuelbuta Segment (perpendicular to the direction of plate motion) probably originate from the collision of the Chiloe Microplate with a marine buttress situated below the Concepcion South Segment. The Chiloe Microplate represents a 1000 km-sized forearc sliver, which is kinematically decoupled from stable South America along the Liquine-Ofqui and Lanalhue Fault Zones. The important transition from wholesale forearc compression to extension observed between the two Concepcion segments, however, is more likely related to plate boundary processes, i.e. different degrees of coupling and/or friction in the plate boundary itself.

  14. Embedded Implementation of VHR Satellite Image Segmentation

    PubMed Central

    Li, Chao; Balla-Arabé, Souleymane; Ginhac, Dominique; Yang, Fan

    2016-01-01

    Processing and analysis of Very High Resolution (VHR) satellite images provide a mass of crucial information, which can be used for urban planning, security issues or environmental monitoring. However, they are computationally expensive and, thus, time consuming, while some of the applications, such as natural disaster monitoring and prevention, require high efficiency performance. Fortunately, parallel computing techniques and embedded systems have made great progress in recent years, and a series of massively parallel image processing devices, such as digital signal processors or Field Programmable Gate Arrays (FPGAs), have been made available to engineers at a very convenient price and demonstrate significant advantages in terms of running-cost, embeddability, power consumption flexibility, etc. In this work, we designed a texture region segmentation method for very high resolution satellite images by using the level set algorithm and the multi-kernel theory in a high-abstraction C environment and realize its register-transfer level implementation with the help of a new proposed high-level synthesis-based design flow. The evaluation experiments demonstrate that the proposed design can produce high quality image segmentation with a significant running-cost advantage. PMID:27240370

  15. A moving hum filter to suppress rotor noise in high-resolution airborne magnetic data

    USGS Publications Warehouse

    Xia, J.; Doll, W.E.; Miller, R.D.; Gamey, T.J.; Emond, A.M.

    2005-01-01

    A unique filtering approach is developed to eliminate helicopter rotor noise. It is designed to suppress harmonic noise from a rotor that varies slightly in amplitude, phase, and frequency and that contaminates aero-magnetic data. The filter provides a powerful harmonic noise-suppression tool for data acquired with modern large-dynamic-range recording systems. This three-step approach - polynomial fitting, bandpass filtering, and rotor-noise synthesis - significantly reduces rotor noise without altering the spectra of signals of interest. Two steps before hum filtering - polynomial fitting and bandpass filtering - are critical to accurately model the weak rotor noise. During rotor-noise synthesis, amplitude, phase, and frequency are determined. Data are processed segment by segment so that there is no limit on the length of data. The segment length changes dynamically along a line based on modeling results. Modeling the rotor noise is stable and efficient. Real-world data examples demonstrate that this method can suppress rotor noise by more than 95% when implemented in an aeromagnetic data-processing flow. ?? 2005 Society of Exploration Geophysicists. All rights reserved.

  16. A parallel finite-difference method for computational aerodynamics

    NASA Technical Reports Server (NTRS)

    Swisshelm, Julie M.

    1989-01-01

    A finite-difference scheme for solving complex three-dimensional aerodynamic flow on parallel-processing supercomputers is presented. The method consists of a basic flow solver with multigrid convergence acceleration, embedded grid refinements, and a zonal equation scheme. Multitasking and vectorization have been incorporated into the algorithm. Results obtained include multiprocessed flow simulations from the Cray X-MP and Cray-2. Speedups as high as 3.3 for the two-dimensional case and 3.5 for segments of the three-dimensional case have been achieved on the Cray-2. The entire solver attained a factor of 2.7 improvement over its unitasked version on the Cray-2. The performance of the parallel algorithm on each machine is analyzed.

  17. Internal Flow Simulation of Enhanced Performance Solid Rocket Booster for the Space Transportation System

    NASA Technical Reports Server (NTRS)

    Ahmad, Rashid A.; McCool, Alex (Technical Monitor)

    2001-01-01

    An enhanced performance solid rocket booster concept for the space shuttle system has been proposed. The concept booster will have strong commonality with the existing, proven, reliable four-segment Space Shuttle Reusable Solid Rocket Motors (RSRM) with individual component design (nozzle, insulator, etc.) optimized for a five-segment configuration. Increased performance is desirable to further enhance safety/reliability and/or increase payload capability. Performance increase will be achieved by adding a fifth propellant segment to the current four-segment booster and opening the throat to accommodate the increased mass flow while maintaining current pressure levels. One development concept under consideration is the static test of a "standard" RSRM with a fifth propellant segment inserted and appropriate minimum motor modifications. Feasibility studies are being conducted to assess the potential for any significant departure in component performance/loading from the well-characterized RSRM. An area of concern is the aft motor (submerged nozzle inlet, aft dome, etc.) where the altered internal flow resulting from the performance enhancing features (25% increase in mass flow rate, higher Mach numbers, modified subsonic nozzle contour) may result in increased component erosion and char. To assess this issue and to define the minimum design changes required to successfully static test a fifth segment RSRM engineering test motor, internal flow studies have been initiated. Internal aero-thermal environments were quantified in terms of conventional convective heating and discrete phase alumina particle impact/concentration and accretion calculations via Computational Fluid Dynamics (CFD) simulation. Two sets of comparative CFD simulations of the RSRM and the five-segment (IBM) concept motor were conducted with CFD commercial code FLUENT. The first simulation involved a two-dimensional axi-symmetric model of the full motor, initial grain RSRM. The second set of analyses included three-dimensional models of the RSRM and FSM aft motors with four-degree vectored nozzles.

  18. A comparative parametric study of a catalytic plate methane reformer coated with segmented and continuous layers of combustion catalyst for hydrogen production

    NASA Astrophysics Data System (ADS)

    Mundhwa, Mayur; Parmar, Rajesh D.; Thurgood, Christopher P.

    2017-03-01

    A parametric comparison study is carried out between segmented and conventional continuous layer configurations of the coated combustion-catalyst to investigate their influence on the performance of methane steam reforming (MSR) for hydrogen production in a catalytic plate reactor (CPR). MSR is simulated on one side of a thin plate over a continuous layer of nickel-alumina catalyst by implementing an experimentally validated surface microkinetic model. Required thermal energy for the MSR reaction is supplied by simulating catalytic methane combustion (CMC) on the opposite side of the plate over segmented and continuous layer of a platinum-alumina catalyst by implementing power law rate model. The simulation results of both coating configurations of the combustion-catalyst are compared using the following parameters: (1) co-flow and counter-flow modes between CMC and MSR, (2) gas hourly space velocity and (3) reforming-catalyst thickness. The study explains why CPR designed with the segmented combustion-catalyst and co-flow mode shows superior performance not only in terms of high hydrogen production but also in terms of minimizing the maximum reactor plate temperature and thermal hot-spots. The study shows that the segmented coating requires 7% to 8% less combustion-side feed flow and 70% less combustion-catalyst to produce the required flow of hydrogen (29.80 mol/h) on the reforming-side to feed a 1 kW fuel-cell compared to the conventional continuous coating of the combustion-catalyst.

  19. Physical basis for river segmentation from water surface observables

    NASA Astrophysics Data System (ADS)

    Samine Montazem, A.; Garambois, P. A.; Calmant, S.; Moreira, D. M.; Monnier, J.; Biancamaria, S.

    2017-12-01

    With the advent of satellite missions such as SWOT we will have access to high resolution estimates of the elevation, slope and width of the free surface. A segmentation strategy is required in order to sub-sample the data set into reach master points for further hydraulic analyzes and inverse modelling. The question that arises is : what will be the best node repartition strategy that preserves hydraulic properties of river flow? The concept of hydraulic visibility introduced by Garambois et al. (2016) is investigated in order to highlight and characterize the spatio-temporal variations of water surface slope and curvature for different flow regimes and reach geometries. We show that free surface curvature is a powerful proxy for characterizing the hydraulic behavior of a reach since concavity of water surface is driven by variations in channel geometry that impacts the hydraulic properties of the flow. We evaluated the performance of three segmentation strategies by means of a well documented case, that of the Garonne river in France. We conclude that local extrema of free surface curvature appear as the best candidate for locating the segment boundaries for an optimal hydraulic representation of the segmented river. We show that for a given river different segmentation scales are possible: a fine-scale segmentation which is driven by fine-scale hydraulic to large-scale segmentation driven by large-scale geomorphology. The segmentation technique is then applied to high resolution GPS profiles of free surface elevation collected on the Negro river basin, a major contributor of the Amazon river. We propose two segmentations: a low-resolution one that can be used for basin hydrology and a higher resolution one better suited for local hydrodynamic studies.

  20. Dysbaric Osteonecrosis in Divers. 1. A Survey of 611 Selected U. S. Navy Divers

    DTIC Science & Technology

    1976-02-24

    ed., Academic Press, New York, 1971, pp 251- 262. 10 7. Asahi, S. H. Ohiwa, and I. Nashimoto, " Avascular Bone Necrosis in Japanese Diving...bone necrosis has been confirmed. 4>5 The confirmation of aseptic bone necrosis in Caisson workers prompted several studies of divers to determine...de- scribe the radiological observations of bone density and structure variations which appear to be aseptic bone necrosis occurring in

  1. Aseptic nonunion of the tibia treated by intramedullary osteosynthesis.

    PubMed

    Gualdrini, G; Rollo, G; Montanari, A; Zinghi, G F

    1996-01-01

    The authors report 52 cases of aseptic nonunion of the tibia treated by intramedullary osteosynthesis. The means of synthesis used were the Küntscher nail, the Eiffel Tower Rush nail, and the Grosse-Kempf nail. Which means of synthesis was used depended on the site and the features of the nonunion. Healing occurred in all of the cases after an average of 5 months. Mean follow-up was 4.5 years.

  2. Modeling heading and path perception from optic flow in the case of independently moving objects

    PubMed Central

    Raudies, Florian; Neumann, Heiko

    2013-01-01

    Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMOs) in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE) in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion/deletion, expansion/contraction, acceleration/deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans' heading and path perception robust in the presence of such IMOs. PMID:23554589

  3. Mumps vaccine virus strains and aseptic meningitis.

    PubMed

    Bonnet, Marie-Claude; Dutta, Anil; Weinberger, Clement; Plotkin, Stanley A

    2006-11-30

    Mumps immunization can easily be included in national schedules, particularly if combined with measles or measles and rubella vaccines, but debate continues concerning the relative safety of various licensed mumps vaccine strains. The opportunities for control of mumps are also being affected by differences in the cost of the vaccines prepared with different strains of mumps virus. The present report evaluates available data on the association of the Urabe and other strains of mumps vaccine with the occurrence of aseptic meningitis. We also review the comparative immunogenicity and efficacies of the most widely used mumps vaccines in controlled clinical trials and field evaluations, and briefly examine relative cost as it relates to the implementation of national immunization programs. We conclude that extensive experience with the most widely used mumps vaccine strains in many countries has shown that the risk-benefit ratio of live mumps vaccines is highly favourable for vaccination, despite the occasional occurence of aseptic meningitis.

  4. Design Considerations of a Compounded Sterile Preparations Course

    PubMed Central

    Petraglia, Christine; Mattison, Melissa J.

    2016-01-01

    Objective. To design a comprehensive learning and assessment environment for the practical application of compounded sterile preparations using a constructivist approach. Design. Compounded Sterile Preparations Laboratory is a required 1-credit course that builds upon the themes of training aseptic technique typically used in health system settings and threads application of concepts from other courses in the curriculum. Students used critical-thinking skills to devise appropriate strategies to compound sterile preparations. Assessment. Aseptic technique skills were assessed with objective, structured, checklist-based rubrics. Most students successfully completed practical assessments using appropriate technique (mean assessment grade=83.2%). Almost all students passed the practical media fill (98%) and gloved fingertip sampling (86%) tests on the first attempt; all passed on the second attempt. Conclusion. Employing a constructivist scaffold approach to teaching proper hygiene and aseptic technique prepared students to pass media fill and gloved fingertip tests and to perform well on practical compounding assessments. PMID:26941438

  5. Irradiated or aseptically prepared frozen dairy desserts: acceptability to bone marrow transplant recipients.

    PubMed

    Dong, F M; Hashisaka, A E; Rasco, B A; Einstein, M A; Mar, D R; Aker, S N

    1992-06-01

    Sterile ice cream and frozen yogurt were offered to immunosuppressed patients recovering from bone marrow transplantation. To obtain sterile products, two of the dairy desserts (prepackaged ice cream and frozen yogurt bars) were exposed to 40 kGy of cobalt 60 irradiation. Four different flavors of ice cream were aseptically prepared under a laminar airflow hood using commercially sterilized ingredients. A commercially sterile, frozen milk-based drink on the low-microbial menu served as the control. Ratings of the seven products by 17 patients indicated that a frozen vanilla milk-based drink and aseptically prepared chocolate ice cream were highly acceptable to recovery immunosuppressed patients who have difficulty eating most foods. However, the seven desserts received higher ratings from a sensory panel of healthy individuals than from the patient panel, confirming that new foods for the low-microbial diet should be "market-tested" by the targeted patient population before inclusion in the menu.

  6. Risk factors for total hip arthroplasty aseptic revision.

    PubMed

    Khatod, Monti; Cafri, Guy; Namba, Robert S; Inacio, Maria C S; Paxton, Elizabeth W

    2014-07-01

    The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001-12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%-97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. High-frequency ultrasonic imaging of growth and development in manufactured engineered oral mucosal tissue surfaces.

    PubMed

    Winterroth, Frank; Kato, Hiroko; Kuo, Shiuhyang; Feinberg, Stephen E; Hollister, Scott J; Fowlkes, J Brian; Hollman, Kyle W

    2014-09-01

    This study uses high-resolution ultrasound to examine the growth and development of engineered oral mucosal tissues manufactured under aseptic conditions. The specimens are a commercially available natural tissue scaffold, AlloDerm, and oral keratinocytes seeded onto AlloDerm to form an ex vivo-produced oral mucosal equivalent (EVPOME) suitable for intra-oral grafting. The seeded cells produce a keratinized protective upper layer that smooths out any remaining surface irregularities on the underlying AlloDerm. Two-dimensional acoustic imaging of unseeded AlloDerm and developing EVPOMEs was performed on each day of their growth and development, each tissue specimen being imaged under aseptic conditions (total time from seeding to maturation: 11 d). Ultrasonic monitoring offers us the ability to determine the constituents of the EVPOME that are responsible for changes in its mechanical behavior during the manufacturing process. Ultrasonic monitoring affords us an opportunity to non-invasively assess, in real time, tissue-engineered constructs before release for use in patient care. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance.

    PubMed

    Di Leo, Giovanni; D'Angelo, Ida Daniela; Alì, Marco; Cannaò, Paola Maria; Mauri, Giovanni; Secchi, Francesco; Sardanelli, Francesco

    2017-03-01

    The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland-Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator's training.

  9. Luminal flow regulates NO and O2− along the nephron

    PubMed Central

    Cabral, Pablo D.

    2011-01-01

    Urinary flow is not constant but in fact highly variable, altering the mechanical forces (shear stress, stretch, and pressure) exerted on the epithelial cells of the nephron as well as solute delivery. Nitric oxide (NO) and superoxide (O2−) play important roles in various processes within the kidney. Reductions in NO and increases in O2− lead to abnormal NaCl and water absorption and hypertension. In the last few years, luminal flow has been shown to be a regulator of NO and O2− production along the nephron. Increases in luminal flow enhance fluid, Na, and bicarbonate transport in the proximal tubule. However, we know of no reports directly addressing flow regulation of NO and O2− in this segment. In the thick ascending limb, flow-stimulated NO and O2− formation has been extensively studied. Luminal flow stimulates NO production by nitric oxide synthase type 3 and its translocation to the apical membrane in medullary thick ascending limbs. These effects are mediated by flow-induced shear stress. In contrast, flow-induced stretch and NaCl delivery stimulate O2− production by NADPH oxidase in this segment. The interaction between flow-induced NO and O2− is complex and involves more than one simply scavenging the other. Flow-induced NO prevents flow from increasing O2− production via cGMP-dependent protein kinase in thick ascending limbs. In macula densa cells, shear stress increases NO production and this requires that the primary cilia be intact. The role of luminal flow in NO and O2− production in the distal tubule is not known. In cultured inner medullary collecting duct cells, shear stress enhances nitrite accumulation, a measure of NO production. Although much progress has been made on this subject in the last few years, there are still many unanswered questions. PMID:21345976

  10. A peculiar segmented flow microfluidics for isoquercitrin biosynthesis based on coupling of reaction and separation.

    PubMed

    Gong, An; Gu, Shuang-Shuang; Wang, Jun; Sheng, Sheng; Wu, Fu-An

    2015-10-01

    A segmented flow containing a buffer-ionic liquid/solvent in a micro-channel reactor was applied to synthesize isoquercitrin by the hesperidinase-catalyzed selective hydrolysis of rutin, based on a novel system of reaction coupling with separation. Within the developed microchannel reactor with one T-shaped inlet and outlet, the maximum isoquercitrin yield (101.7 ± 2.6%) was achieved in 20 min at 30 °C and 4 μL/min. Compared with a continuous-flow reactor, reaction rate was increased 4-fold due to a glycine-sodium hydroxide:[Bmim][BF4]/glycerol triacetate (1:1, v/v) system that formed a slug flow in microchannel and significantly increased mass transfer rates. The mass transfer coefficient significantly increased and exhibited a linear relationship with the flow rate. Hesperidinase could be efficiently reused at least 5 times, without losing any activity. The bonding mechanism and secondary structure of hesperidinase indicated that hesperidinase had a greater affinity to rutin at a production rate of 4 μL/min in this segmented flow microreactor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Considerations in the sterile manufacture of polymeric microneedle arrays.

    PubMed

    McCrudden, Maelíosa T C; Alkilani, Ahlam Zaid; Courtenay, Aaron J; McCrudden, Cian M; McCloskey, Bronagh; Walker, Christine; Alshraiedeh, Nida; Lutton, Rebecca E M; Gilmore, Brendan F; Woolfson, A David; Donnelly, Ryan F

    2015-02-01

    We describe, for the first time, considerations in the sterile manufacture of polymeric microneedle arrays. Microneedles (MN) made from dissolving polymeric matrices and loaded with the model drugs ovalbumin (OVA) and ibuprofen sodium and hydrogel-forming MN composed of "super-swelling" polymers and their corresponding lyophilised wafer drug reservoirs loaded with OVA and ibuprofen sodium were prepared aseptically or sterilised using commonly employed sterilisation techniques. Moist and dry heat sterilisation, understandably, damaged all devices, leaving aseptic production and gamma sterilisation as the only viable options. No measureable bioburden was detected in any of the prepared devices, and endotoxin levels were always below the US Food & Drug Administration limits (20 endotoxin units/device). Hydrogel-forming MN were unaffected by gamma irradiation (25 kGy) in terms of their physical properties or capabilities in delivering OVA and ibuprofen sodium across excised neonatal porcine skin in vitro. However, OVA content in dissolving MN (down from approximately 101.1 % recovery to approximately 58.3 % recovery) and lyophilised wafer-type drug reservoirs (down from approximately 99.7 % recovery to approximately 60.1 % recovery) was significantly reduced by gamma irradiation, while the skin permeation profile of ibuprofen sodium from gamma-irradiated dissolving MN was markedly different from their non-irradiated counterparts. It is clear that MN poses a very low risk to human health when used appropriately, as evidenced here by low endotoxin levels and absence of microbial contamination. However, if guarantees of absolute sterility of MN products are ultimately required by regulatory authorities, it will be necessary to investigate the effect of lower gamma doses on dissolving MN loaded with active pharmaceutical ingredients and lyophilised wafers loaded with biomolecules in order to avoid the expense and inconvenience of aseptic processing.

  12. Generation of chemical movies: FT-IR spectroscopic imaging of segmented flows.

    PubMed

    Chan, K L Andrew; Niu, X; deMello, A J; Kazarian, S G

    2011-05-01

    We have previously demonstrated that FT-IR spectroscopic imaging can be used as a powerful, label-free detection method for studying laminar flows. However, to date, the speed of image acquisition has been too slow for the efficient detection of moving droplets within segmented flow systems. In this paper, we demonstrate the extraction of fast FT-IR images with acquisition times of 50 ms. This approach allows efficient interrogation of segmented flow systems where aqueous droplets move at a speed of 2.5 mm/s. Consecutive FT-IR images separated by 120 ms intervals allow the generation of chemical movies at eight frames per second. The technique has been applied to the study of microfluidic systems containing moving droplets of water in oil and droplets of protein solution in oil. The presented work demonstrates the feasibility of the use of FT-IR imaging to study dynamic systems with subsecond temporal resolution.

  13. An Arduino microcontroller based digitalization of a vertical traversing mechanism used for the analysis of jet flows

    NASA Astrophysics Data System (ADS)

    Rahman, S. M. Rakibur; Roshid, S. M. Al Mamun Or; Nishan, Ishtiaque Ahmed

    2017-12-01

    This paper deals with the design of a drive system of traversing mechanism used to position the pitot tube in desired position of the jet flow field. In this system a stepper motor is driven by a `dual H bridge' motor driver and programmed Arduino microcontroller. The stepper motor is made to move in precise steps to obtain desired movement of the traversing mechanism. The jet flow is characterized in three distinct zones - initial zone, transition zone and developed zone. Each zone can be divided into required number of segments based on variation of velocity. By assigning number of segments, step range and number of steps in each segment as inputs, it is possible to collect data in all the flow zones according to our programmed schedule. The system will allow taking a large number of readings automatically.

  14. Segmented Domain Decomposition Multigrid For 3-D Turbomachinery Flows

    NASA Technical Reports Server (NTRS)

    Celestina, M. L.; Adamczyk, J. J.; Rubin, S. G.

    2001-01-01

    A Segmented Domain Decomposition Multigrid (SDDMG) procedure was developed for three-dimensional viscous flow problems as they apply to turbomachinery flows. The procedure divides the computational domain into a coarse mesh comprised of uniformly spaced cells. To resolve smaller length scales such as the viscous layer near a surface, segments of the coarse mesh are subdivided into a finer mesh. This is repeated until adequate resolution of the smallest relevant length scale is obtained. Multigrid is used to communicate information between the different grid levels. To test the procedure, simulation results will be presented for a compressor and turbine cascade. These simulations are intended to show the ability of the present method to generate grid independent solutions. Comparisons with data will also be presented. These comparisons will further demonstrate the usefulness of the present work for they allow an estimate of the accuracy of the flow modeling equations independent of error attributed to numerical discretization.

  15. The Paradox of Restoring Native River Landscapes and Restoring Native Ecosystems in the Colorado River System

    NASA Astrophysics Data System (ADS)

    Schmidt, J. C.

    2014-12-01

    Throughout the Colorado River basin (CRb), scientists and river managers collaborate to improve native ecosystems. Native ecosystems have deteriorated due to construction of dams and diversions that alter natural flow, sediment supply, and temperature regimes, trans-basin diversions that extract large amounts of water from some segments of the channel network, and invasion of non-native animals and plants. These scientist/manager collaborations occur in large, multi-stakeholder, adaptive management programs that include the Lower Colorado River Multi-Species Conservation Program, the Glen Canyon Dam Adaptive Management Program, and the Upper Colorado River Endangered Species Recovery Program. Although a fundamental premise of native species recovery is that restoration of predam flow regimes inevitably leads to native species recovery, such is not the case in many parts of the CRb. For example, populations of the endangered humpback chub (Gila cypha) are largest in the sediment deficit, thermally altered conditions of the Colorado River downstream from Glen Canyon Dam, but these species occur in much smaller numbers in the upper CRb even though the flow regime, sediment supply, and sediment mass balance are less perturbed. Similar contrasts in the physical and biological response of restoration of predam flow regimes occurs in floodplains dominated by nonnative tamarisk (Tamarix spp.) where reestablishment of floods has the potential to exacerbate vertical accretion processes that disconnect the floodplain from the modern flow regime. A significant challenge in restoring segments of the CRb is to describe this paradox of physical and biological response to reestablishment of pre-dam flow regimes, and to clearly identify objectives of environmentally oriented river management. In many cases, understanding the nature of the perturbation to sediment mass balance caused by dams and diversions and understanding the constraints imposed by societal commitments to provide assured water supplies and hydroelectricity constrains the opportunities for rehabilitation and limits the management objectives to focus either on restoring predam physical processes or recovering native fish fauna and/or recovering native plant communities.

  16. A Study on Water Surface Profiles of Rivers with Constriction

    NASA Astrophysics Data System (ADS)

    Qian, Chaochao; Yamada, Tadashi

    2013-04-01

    Water surface profile of rivers with constrictions is precious in both classic hydraulics and river management practice. This study was conducted to clarify the essences of the water surface profiles. 3 cases of experiments and 1D numerical calculations with different discharges were made in the study and analysis solutions of the non-linear basic equation of surface profile in varied flow without considering friction were derived. The manning's number was kept in the same in each case by using crosspiece roughness. We found a new type of water surface profile of varied flow from the results of 1D numerical calculation and that of experiments and named it as Mc curve because of its mild condition with constriction segment. This kind of curves appears as a nature phenomenon ubiquitously. The process of water surface forming is dynamic and bore occurs at the upper side of constriction during increasing discharge before the surface profile formed. As a theoretical work, 3 analysis solutions were derived included 2 physical-meaning solutions in the study by using Man-Machine system. One of the derived physical-meaning solutions was confirmed that it is validity by comparing to the results of 1D numerical calculation and that of experiments. The solution represents a flow profile from under critical condition at the upper side to super critical condition at the down side of constriction segment. The other derived physical-meaning solution represents a flow profile from super critical condition at the upper side to under critical condition at the down side of constriction segment. These two kinds of flow profiles exist in the nature but no theoretical solution can express the phenomenon. We find the depth distribution only concerned with unit width discharge distribution and critical depth under a constant discharge from the derived solutions. Therefor, the profile can be gained simply and precisely by using the theoretical solutions instead of numerical calculation even in practice.

  17. Simulating dispersion in porous media and the influence of segmentation on stagnancy in carbonates

    NASA Astrophysics Data System (ADS)

    Gray, F.; Cen, J.; Shah, S. M.; Crawshaw, J. P.; Boek, E. S.

    2016-11-01

    Understanding the transport of chemical components in porous media is fundamentally important to many reservoir processes such as contaminant transport and reactive flows involved in CO2 sequestration. Carbonate rocks in particular present difficulties for pore-scale simulations because they contain large amounts of sub-micron porosity. In this work, we introduce a new hybrid simulation model to calculate hydrodynamic dispersion in pore-scale images of real porous media and use this to elucidate the origins and behaviour of stagnant zones arising in transport simulations using micro-CT images of carbonates. For this purpose a stochastic particle model for simulating the transport of a solute is coupled to a Lattice-Boltzmann algorithm to calculate the flow field. The particle method incorporates second order spatial and temporal resolution to resolve finer features of the domain. We demonstrate how dispersion coefficients can be accurately obtained in capillaries, where corresponding analytical solutions are available, even when these are resolved to just a few lattice units. Then we compute molecular displacement distributions for pore-spaces of varying complexity: a pack of beads; a Bentheimer sandstone; and a Portland carbonate. Our calculated propagator distributions are compared directly with recent experimental PFG-NMR propagator distributions (Scheven et al., 2005; Mitchell et al., 2008), the latter excluding spin relaxation mechanisms. We observe that the calculated transport propagators can be quantitatively compared with the experimental distribution, provided that spin relaxations in the experiment are excluded, and good agreement is found for both the sandstone and the carbonate. However, due to the absence of explicit micro-porosity from the carbonate pore space image used for flow field simulations we note that there are fundamental differences in the physical origins of the stagnant zones for micro-porous rocks between simulation and experiment. We show that for a given micro-CT image of a carbonate, small variations in the parameters chosen for the segmentation process lead to different amounts of stagnancy which diffuse away at different rates. Finally, we use a filtering method to show that this is due to the presence of spurious isolated pores which arise from the segmentation process and suggest an approach to overcome this limitation.

  18. Geomorphic Thresholds of Submarine Canyons Along the U.S. Atlantic Continental Margin

    NASA Astrophysics Data System (ADS)

    Brothers, D. S.; ten Brink, U. S.; Andrews, B. D.; Chaytor, J. D.

    2011-12-01

    Vast networks of submarine canyons and associated channels are incised into the U.S. Atlantic continental slope and rise. Submarine canyons form by differential erosion and deposition, primarily from sedimentary turbidity flows. Theoretical and laboratory studies have investigated the initiation of turbidity flows and their capacity to erode and entrain sedimentary material at distances far from the shelf edge. The results have helped understand the nature of turbidite deposits on the continental slope and rise. Nevertheless, few studies have examined the linkages between down-canyon sediment transport and the morphology of canyon/channel networks using mesoscale analyses of swath bathymetry data. We present quantitative analysis of 100-m resolution multibeam bathymetry data spanning ~616,000 km2 of the slope and rise between Georges Banks and the Blake Plateau (New England to North Carolina). Canyons are categorized as shelf-indenting or slope-confined based on spatial scale, vertical relief and connection with terrestrial river systems during sea level low stands. Shelf-indenting canyons usually represent the trunk-canyon of submerged channel networks. On the rise, shelf-indenting canyons have relatively well-developed channel-levees and sharp inner-thalwag incision suggesting much higher frequency and volume of turbidity flows. Because of the similarities between submarine canyon networks and terrestrial river systems, we apply methods originally developed to study fluvial morphology. Along-canyon profiles are extracted from the bathymetry data and the power-law relationship between thalwag gradient and drainage area is examined for more than 180 canyons along an ~1200 km stretch of the US Atlantic margin. We observe distinct thresholds in the power-law relationship between drainage area and gradient. Almost all canyons with heads on the upper slope contain at least two linear segments when plotted in log-log form. The first segment along the upper slope is flat (constant gradient, low area). The second segment dips (exponentially decreasing gradient with increasing area). We interpret the transition between the two segments to be either diffusive creep/landslide processes that evolve into turbidity flows or the boundary that separates up-canyon infilling from relic, lower-canyon incision. Furthermore, the threshold occurs at a nearly constant drainage area regardless of location and morphology of the drainage network. This suggests that time-averaged erosion rate in submarine canyons depends on frequency of turbidity flows, which in turn depends on the volume of unstable sediments deposited near canyon heads and along canyon walls. We find that the gradient-area relationship does not follow a power-law in shelf-indenting canyons, most likely due to allogenic processes of the continental shelf and linkage to terrestrial river discharge.

  19. Evaluating the role of river-floodplain connectivity in providing beneficial hydrologic services in mountain landscapes

    NASA Astrophysics Data System (ADS)

    Covino, T. P.; Wegener, P.; Weiss, T.; Wohl, E.; Rhoades, C.

    2017-12-01

    River networks of mountain landscapes tend to be dominated by steep, valley-confined channels that have limited floodplain area and low hydrologic buffering capacity. Interspersed between the narrow segments are wide, low-gradient segments where extensive floodplains, wetlands, and riparian areas can develop. Although they tend to be limited in their frequency relative to the narrow valley segments, the low-gradient, wide portions of mountain channel networks can be particularly important to hydrologic buffering and can be sites of high nutrient retention and ecosystem productivity. Hydrologic buffering along the wide valley segments is dependent on lateral hydrologic connectivity between the river and floodplain, however these connections have been increasingly severed as a result of various land and water management practices. We evaluated the role of river-floodplain connectivity in influencing water, dissolved organic carbon (DOC), and nutrient flux in river networks of the Colorado Rockies. We found that disconnected segments with limited floodplain/riparian area had limited buffering capacity, while connected segments exhibited variable source-sink dynamics as a function of flow. Specifically, connected segments were typically a sink for water, DOC, and nutrients during high flows, and subsequently became a source as flows decreased. Shifts in river-floodplain hydrologic connectivity across flows related to higher and more variable aquatic ecosystem metabolism rates along connected relative to disconnected segments. Our data suggest that lateral hydrologic connectivity in wide valleys can enhance hydrologic and biogeochemical buffering, and promote high rates of aquatic ecosystem metabolism. While hydrologic disconnection in one river-floodplain system is unlikely to influence water resources at larger scales, the cumulative effects of widespread disconnection may be substantial. Because intact river-floodplain (i.e., connected) systems provide numerous hydrologic and ecologic benefits, understanding the dynamics and cumulative effects of disconnection is an important step toward improved water resource and ecosystem management.

  20. Forest soil erosion prediction as influenced by wildfire and roads

    NASA Astrophysics Data System (ADS)

    Cao, L.; Brooks, E. S.; Elliot, W.

    2017-12-01

    Following a wildfire, the risk of erosion is greatly increased. Forest road networks may change the underlying topography and alter natural flow paths. Flow accumulation and energy can be redistributed by roads and alter soil erosion processes. A LiDAR (Light Detection and Ranging) DEM makes it possible to quantify road topography, and estimate how roads influence surface runoff and sediment transport in a fire-disturbed watershed. With GIS technology and a soil erosion model, this study was carried out to evaluate the effect of roads on erosion and sediment yield following the Emerald Fire southwest of Lake Tahoe. The GeoWEPP model was used to estimate onsite erosion and offsite sediment delivery from each hillslope polygon and channel segment before and after fire disturbance in part of the burned area. The GeoWEPP flow path method was used to estimate the post-fire erosion rate of each GIS pixel. A 2-m resolution LiDAR DEM was used as the terrain layer. The Emerald Fire greatly increased onsite soil loss and sediment yields within the fire boundary. Following the fire, 78.71% of the burned area had predicted sediment yields greater than 4 Mg/ha/yr, compared to the preburn condition when 65.3% of the study area was estimated to generate a sediment yield less than 0.25 Mg/ha/yr. Roads had a remarkable influence on the flow path simulation and sub-catchments delineation, affecting sediment transport process spatially. Road segments acted as barriers that intercepted overland runoff and reduced downslope flow energy accumulation, therefore reducing onsite soil loss downslope of the road. Roads also changed the boundary of sub-catchment and defined new hydrological units. Road segments can transport sediment from one sub-catchment to another. This in turn leads to the redistribution of sediment and alters sediment yield for some sub-catchments. Culverts and road drain systems are of vital importance in rerouting runoff and sediment. Conservation structures can be installed to avoid sediment deposition or debris accumulation on the road surface. On the other hand, the outlets of culverts might be at a high risk of increasing downstream channel erosion due to the large amount of runoff. This implies that conservation measurements should be considered to control the runoff and sediment output from culverts.

  1. No demonstrable association between the Leningrad-Zagreb mumps vaccine strain and aseptic meningitis in a large clinical trial in Egypt.

    PubMed

    Sharma, H J; Oun, S Aly; Bakr, S S Abou; Kapre, S V; Jadhav, S S; Dhere, R M; Bhardwaj, S

    2010-04-01

    To address the claim that the Leningrad-Zagreb (L-Z) mumps vaccine strain is causally associated with aseptic meningitis, a prospective, post-marketing safety study was conducted with a measles-mumps-rubella vaccine (MMR) (TRESIVAC(R); Serum Institute of India Ltd., Pune, India), which uses the L-Z strain as its mumps component in Egypt. In all, 453 119 children (65 423 children aged 16-24 months and 329 211 children aged 5-7 years) received MMR. The control groups which, as a result of local health regulations, were slightly younger than vaccinees, comprised 12 253 and 46 232 children, respectively. Using questionnaires, the parents recorded solicited local, systemic and neurological adverse events for up to 42 days post-vaccination. All data were analysed externally on an intention-to-treat basis by individuals not participating in the study. Local and/or systemic reactions were reported in a small percentage of participants, with pain, fever and parotitis being the most common signs among vaccinees in both age groups. No case of aseptic meningitis, encephalitis, anaphylaxis or convulsions was observed in any participant. Thus, in this series of more than 450 000 Egyptian children, the L-Z mumps vaccine strain in this vaccine did not cause aseptic meningitis. The vaccine is considerably cheaper than Western competitors and a valid alternative to other MMR vaccines.

  2. Viral etiology of aseptic meningitis among children in southern Iran.

    PubMed

    Hosseininasab, Ali; Alborzi, Abdolvahab; Ziyaeyan, Mazyar; Jamalidoust, Marzieh; Moeini, Mahsa; Pouladfar, Gholamreza; Abbasian, Amin; Kadivar, Mohamad Rahim

    2011-05-01

    Aseptic meningitis refers to a clinical syndrome of meningeal inflammation in which bacteria cannot be identified in the cerebrospinal fluid (CSF). The viral etiology and the epidemiological, clinical, and laboratory characteristics of aseptic meningitis among children aged 2 months to 15 years in Shiraz, southern Iran were determined. From May 2007 to April 2008, 65 patients were admitted to the hospital with aseptic meningitis. Seven viruses, non-polio human enteroviruses, mumps virus, herpes simplex virus (HSV), varicella-zoster virus (VZV), human cytomegalovirus (HCMV), human herpes virus type 6 (HHV-6), and Epstein-Barr virus (EBV) were investigated by polymerase chain reaction (PCR) method. Viruses were detected in 30 (46.2%) patients in whom non-polio human enterovirus and mumps virus were detected in 13 (43.3%) and 11 (36.7%), respectively. The remaining 6 (20%) of the cases were caused by HSV, VZV, HCMV, and HHV-6. Haemophilus influenzae and non-polio human enterovirus were detected in one patient simultaneously. Viral meningitis was found to be more frequent during spring and summer. The majority (66.6%) of the patients were treated in the hospital for 10 days and had received antibiotics in the case of bacterial meningitis. Rapid diagnosis of viral meningitis using PCR testing of CSF can help shorten hospitalization, and avoid the unnecessary use of antibiotics. Copyright © 2011 Wiley-Liss, Inc.

  3. Herpes simplex virus type 2-associated recurrent aseptic (Mollaret's) meningitis in genitourinary medicine clinic: a case report.

    PubMed

    Abou-Foul, Ahmad K; Buhary, Thajunisha M; Gayed, Sedki L

    2014-01-01

    Cases of idiopathic recurrent benign aseptic meningitis were first described by Mollaret. Today, herpes simplex virus (HSV) is considered the cause of most cases of Mollaret's meningitis. A 40-year-old male was referred to our genitourinary medicine clinic with recurrent genital herpetic lesions. He had HSV-2-positive genital ulcers 8 years earlier. One year after the first infection, he developed severe recurrent attacks of headache associated with meningitis symptoms. The results of all radiological and biochemical tests were normal, but the patient reported a correlation between his attacks and genital herpes flare-ups. We diagnosed the patient with Mollaret's meningitis and started him on continuous suppressive acyclovir therapy, which resulted in marked clinical improvement. Mollaret's meningitis is a rare form of idiopathic recurrent aseptic meningitis that has a sudden onset, short duration, and spontaneous remission with unpredictable recurrence. We believe that the presence of concurrent or recurrent mucocutaneous herpetic lesions can aid its diagnosis, prior to which, affected patients usually have many unnecessary investigations and treatments. Therefore, detailed sexual history should be sought in all patients with aseptic meningitis, and clinicians should also ask about history of recurrent headaches in all patients with recurrent herpetic anogenital lesions. Continuous suppressive acyclovir therapy may reduce the frequency and severity of attacks and can dramatically improve lifestyle.

  4. Geomorphic characteristics and classification of Duluth-area streams, Minnesota

    USGS Publications Warehouse

    Fitzpatrick, Faith A.; Peppler, Marie C.; DePhilip, Michele M.; Lee, Kathy E.

    2006-01-01

    In 2003 and 2004, a geomorphic assessment of streams in 20 watersheds in the Duluth, Minn., area was conducted to identify and summarize geomorphic characteristics, processes, disturbance mechanisms, and potential responses to disturbance. Methods used to assess the streams included watershed characterization, descriptions of segment slopes and valley types, historical aerial photograph interpretation, and rapid field assessments and intensive field surveys of stream reaches. Geomorphic conditions were summarized into a segment-scale classification with 15 categories mainly based on drainage-network position and slope, and, secondarily, based on geologic setting, valley type, and dominant geomorphic processes. Main causes of geomorphic disturbance included historical logging and agriculture, and ongoing urban development, human-caused channel alterations, road and storm sewer drainage, ditching, hiking trails, and gravel pits or quarries. Geomorphic responses to these disturbances are dependent on a combination of drainage-network position, slope, and geologic setting. Geologic setting is related to drainage-network position because the geologic deposits parallel the Lake Superior shoreline. Headwater streams in large watersheds flow over glacial deposits above altitudes of about 1,200 feet (ft). Headwater tributaries and upper main stems have ditch-like channels with gentle slopes and no valleys. Urban development and road drainage cause increased runoff and flood peaks in these segments resulting in channel widening. Below about 1,200 ft, main-stem segments generally are affected by bedrock type and structure and have steep slopes and confined or entrenched valleys. Increases in flood peaks do not cause incision or widening in the bedrock-controlled valleys; instead, the flow and scour areas are expanded. Feeder tributaries to these main stems have steep, confined valleys and may be sources for sediment from urban areas, road runoff, or storm sewer outfalls. Main-stem segments near the glacial deposits/surficial bedrock contact (1,000–1,200 ft) have the most potential for response to disturbance because they tend to have narrow valleys with sandy glacial lakeshore deposits and moderate slopes. Increases in flood peaks (from upstream increases in runoff) increase the potential for landslides and mass wasting from valley sides as well as channel widening.

  5. Pyrolysis of aseptic packages (tetrapak) in a laboratory screw type reactor and secondary thermal/catalytic tar decomposition.

    PubMed

    Haydary, J; Susa, D; Dudáš, J

    2013-05-01

    Pyrolysis of aseptic packages (tetrapak cartons) in a laboratory apparatus using a flow screw type reactor and a secondary catalytic reactor for tar cracking was studied. The pyrolysis experiments were realized at temperatures ranging from 650 °C to 850 °C aimed at maximizing of the amount of the gas product and reducing its tar content. Distribution of tetrapak into the product yields at different conditions was obtained. The presence of H2, CO, CH4, CO2 and light hydrocarbons, HCx, in the gas product was observed. The Aluminum foil was easily separated from the solid product. The rest part of char was characterized by proximate and elemental analysis and calorimetric measurements. The total organic carbon in the tar product was estimated by elemental analysis of tars. Two types of catalysts (dolomite and red clay marked AFRC) were used for catalytic thermal tar decomposition. Three series of experiments (without catalyst in a secondary cracking reactor, with dolomite and with AFRC) at temperatures of 650, 700, 750, 800 and 850 °C were carried out. Both types of catalysts have significantly affected the content of tars and other components in pyrolytic gases. The effect of catalyst on the tetrapack distribution into the product yield on the composition of gas and on the total organic carbon in the tar product is presented in this work. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Abnormal early diastolic intraventricular flow 'kinetic energy index' assessed by vector flow mapping in patients with elevated filling pressure.

    PubMed

    Nogami, Yoshie; Ishizu, Tomoko; Atsumi, Akiko; Yamamoto, Masayoshi; Kawamura, Ryo; Seo, Yoshihiro; Aonuma, Kazutaka

    2013-03-01

    Recently developed vector flow mapping (VFM) enables evaluation of local flow dynamics without angle dependency. This study used VFM to evaluate quantitatively the index of intraventricular haemodynamic kinetic energy in patients with left ventricular (LV) diastolic dysfunction and to compare those with normal subjects. We studied 25 patients with estimated high left atrial (LA) pressure (pseudonormal: PN group) and 36 normal subjects (control group). Left ventricle was divided into basal, mid, and apical segments. Intraventricular haemodynamic energy was evaluated in the dimension of speed, and it was defined as the kinetic energy index. We calculated this index and created time-energy index curves. The time interval from electrocardiogram (ECG) R wave to peak index was measured, and time differences of the peak index between basal and other segments were defined as ΔT-mid and ΔT-apex. In both groups, early diastolic peak kinetic energy index in mid and apical segments was significantly lower than that in the basal segment. Time to peak index did not differ in apex, mid, and basal segments in the control group but was significantly longer in the apex than that in the basal segment in the PN group. ΔT-mid and ΔT-apex were significantly larger in the PN group than the control group. Multiple regression analysis showed sphericity index, E/E' to be significant independent variables determining ΔT apex. Retarded apical kinetic energy fluid dynamics were detected using VFM and were closely associated with LV spherical remodelling in patients with high LA pressure.

  7. Anatomic and hemodynamic evaluation of renal venous flow in varicocele formation using color Doppler sonography with emphasis on renal vein entrapment syndrome.

    PubMed

    Unlu, Murat; Orguc, Sebnem; Serter, Selim; Pekindil, Gokhan; Pabuscu, Yuksel

    2007-01-01

    To investigate the anatomic and hemodynamic properties of testicular venous drainage and its effects on varicocele formation and reflux using color Doppler ultrasound (US) with emphasis on renal vein entrapment syndrome. Upper abdominal and scrotal US examinations of 35 varicocele patients and 35 healthy male subjects were performed in the supine position during rest, during a Valsalva maneuver and in the erect position. The aortomesenteric angle and distance (AMA and AMD, respectively), peak mean velocities (PVs) and diameters of different segments of renal veins, testicular vein diameters and duration of flow inversion were measured. In the varicocele group, the lateral segment of the left renal vein (LRV) had a larger diameter and slower PV, and the medial segment of the LRV had a smaller diameter and faster PV. The diameter of the dominant draining vein correlated with the PV of the medial and lateral segments of the LRV, whereas there was no correlation between the diameter of the dominant draining vein and the diameters of the right renal vein (RRV) and the lateral segment of the LRV or the PV of the RRV. The duration of flow inversion correlated with the diameter and PV of the medial segment of the LRV. No correlation between the diameters and PVs of the RRV and the lateral segment of the LRV was detected. The decreases in the AMA, AMD, diameter of the medial segment of the LRV and PV of the lateral segment of the LRV, and the increases in the PV of the medial segment of the LRV and the diameter of the lateral segment of the LRV in varicocele patients in all positions suggest the entrapment or impingement of the left renal vein between the aorta and the superior mesenteric artery. This has been defined as the "nutcracker phenomenon", which is known to affect varicocele formation.

  8. Bubble deformations and segmented flows in corrugated microchannels at large capillary numbers

    NASA Astrophysics Data System (ADS)

    Sauzade, Martin; Cubaud, Thomas

    2018-03-01

    We experimentally investigate the interaction between individual bubble deformations and collective distortions of segmented flows in nonlinear microfluidic geometries. Using highly viscous carrier fluids, we study the evolution of monodisperse trains of gas bubbles from a square to a smoothly corrugated microchannel characterized with a series of extensions and constrictions along the flow path. The hysteresis in the bubble shape between accelerating and decelerating flow fields is shown to increase with the capillary number. Measurements of instantaneous bubble velocities reveal the presence of a capillary pull that produces a nonmonotonic behavior for the front velocity in accelerating flow regions. Functional relationships are developed for predicting the morphology and dynamics of viscous multiphase flow patterns at the pore scale.

  9. The Mid-atlantic Ridge (31°S-34°30'S): Temporal and spatial variations of accretionary processes

    NASA Astrophysics Data System (ADS)

    Fox, P. J.; Grindlay, N. R.; MacDonald, K. C.

    1991-02-01

    The ridge located between 31° S and 34°30'S is spreading at a rate of 35 mm yr-1, a transitional velocity between the very slow (≤20 mm yr-1) opening rates of the North Atlantic and Southwest Indian Oceans, and the intermediate rates (60 mm yr-1) of the northern limb of the East Pacific Rise, and the Galapagos and Juan de Fuca Ridges. A synthesis of multi-narrow beam, magnetics and gravity data document that in this area the ridge represents a dynamically evolving system. Here the ridge is partitioned into an ensemble of six distinct segments of variable lengths (12 to 100 km) by two transform faults (first-order discontinuities) and three small offset (< 30 km) discontinuities (second-order discontinuities) that behave non-rigidly creating complex and heterogeneous morphotectonic patterns that are not parallel to flow lines. The offset magnitudes of both the first and second-order discontinuities change in response to differential asymmetric spreading. In addition, along the fossil trace of second-order discontinuities, the lengths of abyssal hills located to either side of a discordant zone are observed to lengthen and shorten creating a saw-toothed pattern. Although the spreading rate remains the same along the length of the ridge studied, the morphology of the spreading segments varies from a deep median valley with characteristics analogous to the rift segments of the North Atlantic to a gently rifted axial bulge that is indistinguishable from the shape and relief of the intermediate rate spreading centers of the East Pacific Rise (i.e., 21°N). Like other carefully surveyed ridge segments at slow and fast rates of accretion, the along-axis profiles of each ridge segment are distinctly convex upwards, and exhibit along-strike changes in relief of 500m to 1500 between the shallowest portion of the segment (approximate center) and the segment ends. Such spatial variations create marked along-axis changes in the morphology and relief of each segment. A relatively low mantle Bouguer anomaly is known to be associated with the ridge segment characterized by a gently rifted axial bulge and is interpreted to indicate the presence of focused mantle upwelling (Kuo and Forsyth, 1988). Moreover, the terrain at the ends of each segment are known to be highly magnetized compared to the centers of each segment (Carbotte et al, 1990). Taken together, these data clearly establish that these profound spatial variations in ridge segment properties between adjoining segments, and along and across each segment, indicate that the upper mantle processes responsible for the formation of this contrasting architecture are not solely related to passive upwelling of the asthenosphere beneath the ridge axis. Rather, there must be differences in the thermal and mechanical structure of the crust and upper mantle between and along the ridge segments to explain these spatial variations in axial topography, crustal structure and magnetization. These results are consistent with the results of investigations from other parts of the ridge and suggest that the emplacement of magma is highly focused along segments and positioned beneath the depth minimum of a given segment. The profound differences between segments indicate that the processes governing the behavior of upwelling mantle are decoupled and the variations in the patterns of axis flanking morphology and rate of accretion indicate that processes controlling upwelling and melt production vary markedly in time as well. At this spreading rate and in this area, the accretionary processes are clearly three-dimensional. In addition, the morphology of a ridge segment is not governed so much by opening rate as by the thermal structure of the mantle which underlies the segment.

  10. A simple and inexpensive method for maintaining a defined flora mouse colony.

    PubMed

    Sedlacek, R S; Mason, K A

    1977-10-01

    The use of autoclaved cages, feed, bedding, water, and filter caps combined with aseptic techniques of animal husbandry in an existing mouse colony was ineffective in maintaining a defined flora colony. The addition of a laminar air flow bench equipped with a high efficiency particulate air filter provided a sterile environment in which to manipulate mice when the filter caps were removed. The installation of a duct to direct all air entering the room through the bench filter reduced the airborne bacterial counts in the room. This modification combined with the culling or marking of infected cages so that no future breeders would be taken from these cages eliminated a number of bacterial contaminants (Staphylococcus aureus, S epidermidis, and streptococci) from the colony.

  11. Prevention of neonatal late-onset sepsis: a randomised controlled trial.

    PubMed

    Alcock, Gary; Liley, Helen G; Cooke, Lucy; Gray, Peter H

    2017-04-04

    Late-onset sepsis (LOS), defined as sepsis occurring after 48 h of age causes substantial mortality and morbidity in very low birth weight infants. Risk factors for LOS include immaturity, intravascular catheters, mechanical ventilation, and prolonged parenteral nutrition (PN). Little attention has been paid to studying the effects of PN administration methods. The aim of the study was to compare a bundle of measures for PN line management incorporating a strict aseptic technique with standard line management on LOS in very low birth weight infants. Infants <1500 g birth weight who required PN were randomised to either a bundle of a strict aseptic technique for line management together with single use intravascular catheter for PN or a standard technique. The primary outcome was the incidence of LOS in the first 28 days of life. Secondary outcomes were mortality, neonatal morbidities and developmental outcome at 12 months of age. There were 126 infants in the aseptic technique group and 123 in the standard technique group. Forty (31.8%) infants in the aseptic technique group and 36 (29.3%) in the standard technique group had an episode of sepsis (p = 0.77). This corresponds to incidences of 15.8 and 14.2 episodes of sepsis per 1000 patient days respectively. Subgroup analyses for infants <1000 g also revealed no difference in the rate of sepsis between the intervention and control groups. (p = 0.43). There were no significant differences in secondary outcomes and development between the groups. A bundle of measures including strict aseptic technique for parenteral nutrition line management did not result in a reduction in LOS when compared to a standard technique. There is no evidence to recommend this as routine practice. Interdisciplinary Maternal Perinatal Australasian Collaborative Trials (IMPACT) Network, TRN registration number: PT0363. Date: 06/03/2001; Australian New Zealand Clinical Trials Registry (ANZCTR), TRN registration number: ACTRN12617000455369 . Date: 28/03/2017 (retrospectively registered).

  12. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    PubMed

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  13. Rheoencephalographic (REG) Assessment of Head and Neck Cooling for use with Multiple Sclerosis Patients

    NASA Technical Reports Server (NTRS)

    Montogomery, Leslie D.; Ku, Yu-Tsuan E.; Webbon, Bruce W. (Technical Monitor)

    1995-01-01

    We have prepared a computer program (RHEOSYS:RHEOencephalographic impedance trace scanning SyStem) that can be used to automate the analysis of segmental impedance blood flow waveforms. This program was developed to assist in the post test analysis of recorded impedance traces from multiple segments of the body. It incorporates many of the blood flow, segmental volume, and vascular state indices reported in the world literature. As it is currently programmed, seven points are selected from each blood flow pulse and associated ECG waveforrn: 1. peak of the first ECG QRS complex, 2. start of systolic slope on the blood flow trace, 3. maximum amplitude of the impedance pulse, 4. position of the dicrotic notch, 5. maximum amplitude of the postdicrotic segment, 6. peak of the second ECG QRS complex, and 7. start of the next blood flow pulse. These points we used to calculate various geometric, area, and time-related values associated with the impedance pulse morphology. RHEOSYS then calculates a series of 34 impedance and cardiac cycle parameters which include pulse amplitudes; areas; pulse propagation times; cardiac cycle times; and various measures of arterial and various tone, contractility, and pulse volume. We used this program to calculate the scalp and intracranial blood flow responses to head and neck cooling as it may be applied to lower the body temperatures of multiple sclerosis patients. Twelve women and twelve men were tested using a commercially available head and neck cooling system operated at its maximum cooling capacity for a period of 30 minutes. Head and neck cooling produced a transient change in scalp blood flow and a significant, (P<0.05) decrease of approx. 30% in intracranial blood flow. Results of this experiment will illustrate how REG and RHEOSYS can be used in biomedical applications.

  14. Cell stimulus and lysis in a microfluidic device with segmented gas-liquid flow.

    PubMed

    El-Ali, Jamil; Gaudet, Suzanne; Günther, Axel; Sorger, Peter K; Jensen, Klavs F

    2005-06-01

    We describe a microfluidic device with rapid stimulus and lysis of mammalian cells for resolving fast transient responses in cell signaling networks. The device uses segmented gas-liquid flow to enhance mixing and has integrated thermoelectric heaters and coolers to control the temperature during cell stimulus and lysis. Potential negative effects of segmented flow on cell responses are investigated in three different cell types, with no morphological changes and no activation of the cell stress-sensitive mitogen activated protein kinases observed. Jurkat E6-1 cells are stimulated in the device using alpha-CD3, and the resulting activations of ERK and JNK are presented for different time points. Stimulation of cells performed on chip results in pathway activation identical to that of conventionally treated cells under the same conditions.

  15. Vortex nozzle for segmenting and transporting metal chips from turning operations

    DOEpatents

    Bieg, L.F.

    1993-04-20

    Apparatus for collecting, segmenting and conveying metal chips from machining operations utilizes a compressed gas driven vortex nozzle for receiving the chip and twisting it to cause the chip to segment through the application of torsional forces to the chip. The vortex nozzle is open ended and generally tubular in shape with a converging inlet end, a constant diameter throat section and a diverging exhaust end. Compressed gas is discharged through angled vortex ports in the nozzle throat section to create vortex flow in the nozzle and through an annular inlet at the entrance to the converging inlet end to create suction at the nozzle inlet and cause ambient air to enter the nozzle. The vortex flow in the nozzle causes the metal chip to segment and the segments thus formed to pass out of the discharge end of the nozzle where they are collected, cleaned and compacted as needed.

  16. 4D flow mri post-processing strategies for neuropathologies

    NASA Astrophysics Data System (ADS)

    Schrauben, Eric Mathew

    4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications. Not surprisingly, the last decade has seen rapid growth in the use of 4D flow MRI. Data acquisition sequences are available to researchers on all major scanner platforms. However, the use has been limited mostly to small research trials. One major reason that has hindered the more widespread use and application in larger clinical trials is the complexity of the post-processing tasks and the lack of adequate tools for these tasks. Post-processing of 4D flow MRI must be semi-automated, fast, user-independent, robust, and reliably consistent for use in a clinical setting, within large patient studies, or across a multicenter trial. Development of proper post-processing methods coupled with systematic investigation in normal and patient populations pushes 4D flow MRI closer to clinical realization while elucidating potential underlying neuropathological origins. Within this framework, the work in this thesis assesses venous flow reproducibility and internal consistency in a healthy population. A preliminary analysis of venous flow parameters in healthy controls and multiple sclerosis patients is performed in a large study employing 4D flow MRI. These studies are performed in the context of the chronic cerebrospinal venous insufficiency hypothesis. Additionally, a double-gated flow acquisition and reconstruction scheme demonstrates respiratory-induced changes in internal jugular vein flow. Finally, a semi-automated intracranial vessel segmentation and flow parameter measurement software tool for fast and consistent 4D flow post-processing analysis is developed, validated, and exhibited an in-vivo.

  17. [Differentiated physiotherapy of lumbar pain].

    PubMed

    Chernyshova, L P; Galimova, E S

    2011-01-01

    The results of the present study confirm the efficacy of combined differential treatment of pain sensation in the lower back with the use of the up-to-date physiotherapeutic methods. The choice of a concrete method depended on the mechanism of development of the vertebral syndrome (compression, disfixation, disgenia or aseptic inflammation). The treatment resulted in the improvement of major integral characteristics of the pathological process, marked reduction in the duration of therapy, and significant prolongation of the remission period.

  18. Sensory Characteristics and Consumer Acceptance of Frozen Cooked Rice by a Rapid Freezing Process Compared to Homemade and Aseptic Packaged Cooked Rice

    PubMed Central

    Kwak, Han Sub; Kim, Hye-Gyeong; Kim, Hyun Suk; Ahn, Yong Sik; Jung, Kyunghee; Jeong, Hyo-Young; Kim, Tae Hyeong

    2013-01-01

    Descriptive analysis and consumer acceptance tests were conducted with frozen (FCR), homemade (HCR), and aseptic-packaged (ACR) cooked rice products from two cultivars–IM and SD. FCR was prepared using a rapid freezing process, which may provide consumers with a quality similar to that of HCR. The intensity of the flavors of roasted, glutinous rice, rice cake, and rice starch and the textures of glutinousness, moistness, chunkiness, adhesiveness, and squishiness were all greater in the FCR as compared to the HCR and ACR (p<0.05) in IM and SD cultivars. The differences in sensory characteristics between the FCR and ACR were larger than the equivalent differences between the FCR and HCR. Overall consumer acceptance ratings for FCR in overall aspect, appearance, aroma, and texture were not significantly different compared to those for HCR (p>0.05); however, in most cases these factors showed significant differences when compared with ACR (p<0.05). From partial least square regression analysis, cooked rice was positively related to sweet, transparency, glossiness, roasted, glutinousness, chunkiness, moistness, glutinous rice, adhesiveness, rice shape, rice starch, and squishiness attributes but negatively related to raw rice, old rice, old rice aroma, a particle feeling, off-aroma, white color, scatteredness, slickness, size of cooked rice, and firmness attributes. PMID:24471112

  19. A combined basalt and peridotite perspective on 14 million years of melt generation at the Atlantis Bank segment of the Southwest Indian Ridge: Evidence for temporal changes in mantle dynamics?

    USGS Publications Warehouse

    Coogan, L.A.; Thompson, G.M.; MacLeod, C.J.; Dick, H.J.B.; Edwards, S.J.; Hosford, Scheirer A.; Barry, T.L.

    2004-01-01

    Little is known about temporal variations in melt generation and extraction at midocean ridges largely due to the paucity of sampling along flow lines. Here we present new whole-rock major and trace element data, and mineral and glass major element data, for 71 basaltic samples (lavas and dykes) and 23 peridotites from the same ridge segment (the Atlantis Bank segment of the Southwest Indian Ridge). These samples span an age range of almost 14 My and, in combination with the large amount of published data from this area, allow temporal variations in melting processes to be investigated. Basalts show systematic changes in incompatible trace element ratios with the older samples (from ???8-14 Ma) having more depleted incompatible trace element ratios than the younger ones. There is, however, no corresponding change in peridotite compositions. Peridotites come from the top of the melting column, where the extent of melting is highest, suggesting that the maximum degree of melting did not change over this interval of time. New and published Nd isotopic ratios of basalts, dykes and gabbros from this segment suggest that the average source composition has been approximately constant over this time interval. These data are most readily explained by a model in which the average source composition and temperature have not changed over the last 14 My, but the dynamics of mantle flow (active-to-passive) or melt extraction (less-to-more efficient extraction from the 'wings' of the melting column) has changed significantly. This hypothesised change in mantle dynamics occurs at roughly the same time as a change from a period of detachment faulting to 'normal' crustal accretion. We speculate that active mantle flow may impart sufficient shear stress on the base of the lithosphere to rotate the regional stress field and promote the formation of low angle normal faults. ?? 2004 Elsevier B.V. All rights reserved.

  20. An experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane

    PubMed Central

    El-Warrak, Alexander O; Olmstead, Marvin; Schneider, Rebecca; Meinel, Lorenz; Bettschart-Wolfisberger, Regula; Akens, Margarete K; Auer, Joerg; von Rechenberg, Brigitte

    2004-01-01

    Background Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and discussed controversially. Therefore, the goal of this study was to establish an experimental animal model in sheep allowing to follow the cascade of early mechanical and biochemical events within the interface membrane and study the sequence of how they contribute to the pathological bone resorption necessary for aseptic loosening of the implant. Methods A cemented modular system (Biomedtrix) was used as a hip replacement in 24 adult Swiss Alpine sheep, with one group receiving a complete cement mantle as controls (n = 12), and the other group a cement mantle with a standardized, lateral, primary defect in the cement mantle (n = 12). Animals were followed over time for 2 and 8.5 months (n = 6 each). After sacrifice, samples from the interface membranes were harvested from five different regions of the femur and joint capsule. Explant cell cultures were performed and supernatant of cultures were tested and assayed for nitric oxide, prostaglandin E2, caseinolytic and collagenolytic activity. RNA extraction and quantification were performed for inducible nitric oxide synthase, cyclooxygenase-2, interleukin 1, and interleukin 6. Overall differences between groups and time periods and interactions thereof were calculated using a factorial analysis of variance (ANOVA). Results The development of an interface membrane was noticed in both groups at both time points. However, in the controls the interface membrane regressed in thickness and biological activity, while both variables increased in the experimental group with the primary cement mantle defect over time. Nitric oxide (NO) and PGE2 concentrations were higher in the 8.5 months group (P < 0.0001) compared to the 2 months group with a tendency for the unstable group to have higher concentrations. The same was true for collagenolytic activity (P = 0.05), but not for caseinolytic activity that decreased over time (P < 0.0001). Conclusion In this study, a primary cement mantle defect of the femoral shaft elicited biomechanical instability and biochemical changes over time in an experimental animal study in sheep, that resembled the changes described at the bone cement-interface in aseptic loosening of total hip prosthesis in humans. The early biochemical changes may well explain the pathologic bone resorption and formation of an interface membrane as is observed in clinical cases. This animal model may aid in future studies aiming at prevention of aseptic loosening of hip prosthesis and reflect some aspects of the pathogenesis involved. PMID:15113432

  1. Improving CCTA-based lesions' hemodynamic significance assessment by accounting for partial volume modeling in automatic coronary lumen segmentation.

    PubMed

    Freiman, Moti; Nickisch, Hannes; Prevrhal, Sven; Schmitt, Holger; Vembar, Mani; Maurovich-Horvat, Pál; Donnelly, Patrick; Goshen, Liran

    2017-03-01

    The goal of this study was to assess the potential added benefit of accounting for partial volume effects (PVE) in an automatic coronary lumen segmentation algorithm that is used to determine the hemodynamic significance of a coronary artery stenosis from coronary computed tomography angiography (CCTA). Two sets of data were used in our work: (a) multivendor CCTA datasets of 18 subjects from the MICCAI 2012 challenge with automatically generated centerlines and 3 reference segmentations of 78 coronary segments and (b) additional CCTA datasets of 97 subjects with 132 coronary lesions that had invasive reference standard FFR measurements. We extracted the coronary artery centerlines for the 97 datasets by an automated software program followed by manual correction if required. An automatic machine-learning-based algorithm segmented the coronary tree with and without accounting for the PVE. We obtained CCTA-based FFR measurements using a flow simulation in the coronary trees that were generated by the automatic algorithm with and without accounting for PVE. We assessed the potential added value of PVE integration as a part of the automatic coronary lumen segmentation algorithm by means of segmentation accuracy using the MICCAI 2012 challenge framework and by means of flow simulation overall accuracy, sensitivity, specificity, negative and positive predictive values, and the receiver operated characteristic (ROC) area under the curve. We also evaluated the potential benefit of accounting for PVE in automatic segmentation for flow simulation for lesions that were diagnosed as obstructive based on CCTA which could have indicated a need for an invasive exam and revascularization. Our segmentation algorithm improves the maximal surface distance error by ~39% compared to previously published method on the 18 datasets from the MICCAI 2012 challenge with comparable Dice and mean surface distance. Results with and without accounting for PVE were comparable. In contrast, integrating PVE analysis into an automatic coronary lumen segmentation algorithm improved the flow simulation specificity from 0.6 to 0.68 with the same sensitivity of 0.83. Also, accounting for PVE improved the area under the ROC curve for detecting hemodynamically significant CAD from 0.76 to 0.8 compared to automatic segmentation without PVE analysis with invasive FFR threshold of 0.8 as the reference standard. Accounting for PVE in flow simulation to support the detection of hemodynamic significant disease in CCTA-based obstructive lesions improved specificity from 0.51 to 0.73 with same sensitivity of 0.83 and the area under the curve from 0.69 to 0.79. The improvement in the AUC was statistically significant (N = 76, Delong's test, P = 0.012). Accounting for the partial volume effects in automatic coronary lumen segmentation algorithms has the potential to improve the accuracy of CCTA-based hemodynamic assessment of coronary artery lesions. © 2017 American Association of Physicists in Medicine.

  2. Plasma Decontamination: A Case Study on Kill Efficacy of Geobacillus stearothermophilus Spores on Different Carrier Materials.

    PubMed

    Semmler, Egmont; Novak, Wenzel; Allinson, Wilf; Wallis, Darren; Wood, Nigel; Awakowicz, Peter; Wunderlich, Joachim

    2016-01-01

    A new technology to the pharmaceutical field is presented: surface decontamination by plasmas The technology is comparable to established barrier systems like e-beam, volatile hydrogen peroxide, or radiation inactivation of microbiological contaminations. This plasma technology is part of a fully automated and validated syringe filling line at a major pharmaceutical company and is in production operation. Incoming pre-sterilized syringe containers ("tubs") are processed by plasma, solely on the outside, and passed into the aseptic filling isolator upon successful decontamination. The objective of this article is to present the operating principles and develop and establish a validation routine on the basis of standard commercial biological indicators. Their decontamination efficacies are determined and correlated to the actual inactivation efficacy on the pharmaceutical packaging material.The reference setup is explained in detail and a short presentation of the cycle development and the relevant plasma control parameters is given, with a special focus on the in-process monitor determining the cycle validity. Different microbial inactivation mechanisms are also discussed and evaluated for their contribution and interaction to enhance plasma decontamination. A material-dependent inactivation behavior was observed. In order to be able to correlate the tub surface inactivation of Geobacillus stearothermophilus endospores to metallic biological indicators, a comparative study was performed. Through consistently demonstrating the linear inactivation behavior between the different materials, it becomes possible to develop an effective and time-saving validation scheme. The challenge in new decontamination systems lies in a thorough validation of the inactivation efficacy under different operating regimes. With plasma, as an ionized gas, a new barrier concept is introduced into pharmaceutical aseptic processing of syringes. The presented system operates in vacuum and only decontaminates the outer surface of pre-sterilized syringe containers ("tubs"), before they are transferred into the aseptic area. The plasma does not penetrate into the tub. This article discusses the phase from development and test germ selection, across the identified sporicidal mechanisms, to a proposal for a validation scheme on the basis of commercially available biological indicators. A special focus is placed on an extensive investigation to establish a link between the tub surface microbial kill (polystyrene and Tyvek(and (2)) ) and biological indicator inactivation (stainless steel). Additionally, a rationale is developed on how an optical in-process monitor can be applied to establish a validatable limit on the base of the predetermined inactivation data of Geobacillus stearothermophilus endospores. © PDA, Inc. 2016.

  3. Airlift Cargo Hub Port Hold Times: Controlling Variations in Defense Supply Chain Delivery

    DTIC Science & Technology

    2010-06-01

    AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED...Department of Operational Sciences Graduate School of Engineering and Management Air Force Institute of Technology Air University Air...process for a seamless flow of cargo onto the aircraft segment (AMC and DDC , 24 Sep 08). Figure 6 AMC Velocity Efforts (Anderson D. , 2009) While

  4. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    NASA Astrophysics Data System (ADS)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was validated quantitatively by comparing it with the CO values measured from the volume flow in the pulmonary artery. Relative bias varied between 0 and -17%, where the nominal accuracy of the flow meter is in the order of 10%. Assuming the CO measurements from the flow probe as a gold standard, excellent correlation (r = 0.99) was observed with the CO estimates obtained from image segmentation.

  5. Solvent extraction employing a static micromixer: a simple, robust and versatile technology for the microencapsulation of proteins.

    PubMed

    Freitas, S; Walz, A; Merkle, H P; Gander, B

    2003-01-01

    The potential of a static micromixer for the production of protein-loaded biodegradable polymeric microspheres by a modified solvent extraction process was examined. The mixer consists of an array of microchannels and features a simple set-up, consumes only very small space, lacks moving parts and offers simple control of the microsphere size. Scale-up from lab bench to industrial production is easily feasible through parallel installation of a sufficient number of micromixers ('number-up'). Poly(lactic-co-glycolic acid) microspheres loaded with a model protein, bovine serum albumin (BSA), were prepared. The influence of various process and formulation parameters on the characteristics of the microspheres was examined with special focus on particle size distribution. Microspheres with monomodal size distributions having mean diameters of 5-30 micro m were produced with excellent reproducibility. Particle size distributions were largely unaffected by polymer solution concentration, polymer type and nominal BSA load, but depended on the polymer solvent. Moreover, particle mean diameters could be varied in a considerable range by modulating the flow rates of the mixed fluids. BSA encapsulation efficiencies were mostly in the region of 75-85% and product yields ranged from 90-100%. Because of its simple set-up and its suitability for continuous production, static micromixing is suggested for the automated and aseptic production of protein-loaded microspheres.

  6. Controls on mid-ocean ridge segmentation and transform fault formation from laboratory experiments using fluids of complex rheology.

    NASA Astrophysics Data System (ADS)

    Sibrant, A.; Mittelstaedt, E. L.; Davaille, A.

    2017-12-01

    Mid-ocean ridges are tectonically segmented at scales of 10s to 100s of kilometers by several types of offsets including transform faults (TF), overlapping spreading centers (OSC), and slow-spreading non-transform offsets (NTO). Differences in segmentation along axis have been attributed to changes in numerous processes including magma supply from the upwelling mantle, viscous flow in the asthenosphere, ridge migration, and plate spreading direction. The wide variety of proposed mechanisms demonstrate that the origin of tectonic offsets and their relationship to segment-scale magmatic processes remain actively debated; each of the above processes, however, invoke combinations of tectonic and magmatic processes to explain changes in segmentation. To address the role of tectonic deformation and magmatic accretion on the development of ridge offsets, we present a series of analogue experiments using colloidal silica dispersions as an Earth analogue. Saline water solutions placed in contact with these fluids, cause formation of a skin through salt diffusion, whose rheology evolves from purely viscous to elastic and brittle with increasing salinity. Experiments are performed in a Plexiglas tank with two Plexiglas plates suspended above the base of the tank. The tank is filled with the colloidal fluid to just above the suspended plates, a thin layer of saline water is spread across the surface, and spreading initiated by moving the suspended Plexiglas plates apart at a fixed rate. Results show formation of OSCs, NTOs, and TFs. For parameters corresponding to the Earth, TF offsets are < 5 mm and form at all spreading velocities, corresponding to transform offsets of < 100 km on Earth. Measured TF offset size and ridge segment lengths exhibit a Poisson-type distribution with no apparent dependence on spreading rate. Observations of TF offset size on Earth show a similar distribution for TFs <100 km long and supports the hypothesis that TFform spontaneously through a mechanical instability of the axis. Here, we present an analysis of the magmatic and tectonic controls on axis instability leading to the formation of TFs, OSCs, and NTOs, and their implications for the evolution of mid-ocean ridges.

  7. Shape-controlled continuous synthesis of metal nanostructures

    NASA Astrophysics Data System (ADS)

    Sebastian, Victor; Smith, Christopher D.; Jensen, Klavs F.

    2016-03-01

    A segmented flow-based microreactor is used for the continuous production of faceted nanocrystals. Flow segmentation is proposed as a versatile tool to manipulate the reduction kinetics and control the growth of faceted nanostructures; tuning the size and shape. Switching the gas from oxygen to carbon monoxide permits the adjustment in nanostructure growth from 1D (nanorods) to 2D (nanosheets). CO is a key factor in the formation of Pd nanosheets and Pt nanocubes; operating as a second phase, a reductant, and a capping agent. This combination confines the growth to specific structures. In addition, the segmented flow microfluidic reactor inherently has the ability to operate in a reproducible manner at elevated temperatures and pressures whilst confining potentially toxic reactants, such as CO, in nanoliter slugs. This continuous system successfully synthesised Pd nanorods with an aspect ratio of 6; thin palladium nanosheets with a thickness of 1.5 nm; and Pt nanocubes with a 5.6 nm edge length, all in a synthesis time as low as 150 s.A segmented flow-based microreactor is used for the continuous production of faceted nanocrystals. Flow segmentation is proposed as a versatile tool to manipulate the reduction kinetics and control the growth of faceted nanostructures; tuning the size and shape. Switching the gas from oxygen to carbon monoxide permits the adjustment in nanostructure growth from 1D (nanorods) to 2D (nanosheets). CO is a key factor in the formation of Pd nanosheets and Pt nanocubes; operating as a second phase, a reductant, and a capping agent. This combination confines the growth to specific structures. In addition, the segmented flow microfluidic reactor inherently has the ability to operate in a reproducible manner at elevated temperatures and pressures whilst confining potentially toxic reactants, such as CO, in nanoliter slugs. This continuous system successfully synthesised Pd nanorods with an aspect ratio of 6; thin palladium nanosheets with a thickness of 1.5 nm; and Pt nanocubes with a 5.6 nm edge length, all in a synthesis time as low as 150 s. Electronic supplementary information (ESI) available: ESI Fig. S1-S8. See DOI: 10.1039/c5nr08531d

  8. Passenger flow rates between compartments : straight-segmented stairways, spiral stairways, and passageways with restricted vision and changes of attitude.

    DOT National Transportation Integrated Search

    1978-01-01

    Data are presented from 210 trials to compare movement up and down spiral and straight-segmented stairways simulating the stairs in multideck transport aircraft, up and down spiral and straight-segmented industrial-type stairways, fore and aft throug...

  9. Temporal and Spatial Variability in the Geochemistry of Axial and CoAxial Segment Lavas and their Mantle Sources

    NASA Astrophysics Data System (ADS)

    Smith, M. C.; Perfit, M. R.; Davis, C.; Kamenov, G. D.

    2011-12-01

    Three spatially related volcanic eruptions along the CoAxial Segment of the Juan de Fuca Ridge (JdFR) have documented emplacements between 1981 and 1993. Two of the historic flows outcrop at the "Flow Site" and were emplaced within less than 12 years and 500 m from one another. The third was emplaced at the "Floc Site" to the south in the 1980s. Previous studies have documented that CoAxial lavas are among the most incompatible element and isotopically depleted lavas along the entire JdFR, whereas the Axial Seamount segment immediately south of CoAxial has erupted the most chemically enriched lavas south of the Endeavor Segment. Geochemical studies have shown little temporal change in the chemistry of recent Axial Seamount eruptives, whereas CoAxial lavas exhibit distinct chemical differences over short time periods. Significant chemical differences observed among depleted CoAxial lavas emplaced close to one another in space and time are in marked contrast to the relatively constant chemical characteristics of enriched lavas erupted at the magmatically more robust Axial segment only 10's of kilometers to the south and west. New trace element and isotopic (Sr, Nd, Pb) geochemical analyses of historic and older CoAxial lavas have resulted in better documentation of interflow and intraflow chemical variation providing an improved understanding of spatial/temporal chemical variability in lavas, and further insight into JdFR magmatic processes. Modeling of major and trace element abundances suggest that the observed intraflow chemical variation within CoAxial lavas is largely due to shallow-level fractional crystallization but that a single fractional crystallization model cannot account for all interflow chemical variation. In fact, elemental and isotopic data require different parental magmas for each of the three recent CoAxial Segment lava flows suggesting very short-term differences or changes in the chemical character of the mantle source region. In particular, the 1980's Flow Site parental magma may have formed at higher pressures and due to smaller extents of melting than those magmas that erupted just over a decade later. A comparative analysis of the chemistry of CoAxial segment lavas with that of lavas from nearby seamounts, including Axial Seamount, and ridge segments show that much (though not all) of the data conforms well to binary mixing arrays, suggesting that many of the parental lavas from this region of the JdFR can be formed from variable amounts of mixing of two or more distinct mantle end-member sources. In addition to one or more depleted mantle (DM) sources, regional isotopic data also likely suggest a high U/Pb (HIMU) source component within the region of mantle melt generation. For most lavas strong correlations exist between long-lived radiogenic isotopes and ratios of the abundances of highly incompatible elements, suggesting that mantle heterogeneities sampled are ancient, however, in some cases elemental data is decoupled from the radiogenic isotope data indicating more recent depletion events.

  10. Packaging's Contribution for the Effectiveness of the Space Station's Food Service Operation

    NASA Technical Reports Server (NTRS)

    Rausch, B. A.

    1985-01-01

    Storage limitations will have a major effect on space station food service. For example: foods with low bulk density such as ice cream, bread, cake, standard type potato chips and other low density snacks, flaked cereals, etc., will exacerbate the problem of space limitations; package containers are inherently volume consuming and refuse creating; and the useful observation that the optimum package is no package at all leads to the tentative conclusion that the least amount of packaging per unit of food, consistent with storage, aesthetics, preservation, cleanliness, cost and disposal criteria, is the most practical food package for the space station. A series of trade offs may have to be made to arrive at the most appropriate package design for a particular type of food taking all the criteria into account. Some of these trade offs are: single serve vs. bulk; conventional oven vs. microwave oven; nonmetallic aseptically vs. non-aseptically packaged foods; and comparison of aseptic vs. nonaseptic food packages. The advantages and disadvantages are discussed.

  11. Molecular identification of enteroviruses associated with aseptic meningitis in children from India.

    PubMed

    Kumar, Arvind; Shukla, Deepti; Kumar, Rashmi; Idris, Mohammad Z; Jauhari, Prashant; Srivastava, Shalini; Dhole, Tapan N

    2013-01-01

    We identified and characterized enteroviruses associated with aseptic meningitis in children between April 2009 and March 2010. Enterovirus RNA was detected in 51 (45.5 %) of 112 CSF samples. Molecular typing by RT-PCR and sequencing of a partial VP1 region revealed the predominance of echovirus (ECV) 32 (n = 20), followed by ECV 11 (n = 10), ECV 13 and ECV 14 (n = 5 each), coxsackievirus (CV) B3 and CV B6 (n = 3 each), CV A2, CV A10 and ECV 30 (n = 1 each). Phylogenetic analysis of ECV 32 showed 0 to 4 % sequence divergence among strains of the present study and 20-23 % from the prototype Puerto Rico strain at the nucleotide level. This is the first report of ECV 32 associated with an aseptic meningitis epidemic and identification of seven different enterovirus serotypes (CV A2, CV A10, CV B3, CV B6, ECV 13, ECV 14 and ECV 32) in meningitis cases from India.

  12. Reduction of Urinary Tract Infections Caused By Urethral Catheter through the Implementation of Hydrophobic Coating and Geometrical Modifications

    NASA Astrophysics Data System (ADS)

    Gare, Aya

    2013-11-01

    Catheter-Associated Urinary Tract Infection (CAUTI) is the most common nosocomial infection in the U.S. healthcare system. The obstruction of urine caused by confined air bubbles result in the development of urinary back-flow and stagnation, wherein microbial pathogens could multiply rapidly and colonization within catheters become commonplace. Infections can be prevented by aseptic insertion and the maintenance of a closed drainage system, keeping high infection control standards, and preventing back-flow from the catheter bag. The goal of this study is to assess the effectiveness of a simple, low cost, modification that may be implemented into current catheter designs to reduce the incidence of CAUTI. Using the principle of transmission of fluid-pressure and the Young-Laplace equation for capillary pressure difference, this research focuses on improving the liquid flow in the presence of confined bubbles to prevent stagnation and reflux of bacteria-ridden urine into the body. Preliminary experiments are performed on a variety of tubes with hydrophobic-coating the interior, as well as geometrically modifying the tubes. Proof-of-Concept Prototype tubes are used to represent the drainage system of the catheter structure.

  13. Segmental Blood Flow and Hemodynamic State of Lymphedematous and Nonlymphedematous Arms

    PubMed Central

    Montgomery, Leslie D.; Dietrich, Mary S.; Armer, Jane M.; Stewart, B. R.

    2011-01-01

    Abstract Background Findings regarding the influence hemodynamic factors, such as increased arterial blood flow or venous abnormalities, on breast cancer treatment-related lymphedema are mixed. The purpose of this study was to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal individuals without lymphedema. Methods and Results A Tetrapolar High Resolution Impedance Monitor and Cardiotachometer were used to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal volunteers. Average arterial blood flow in lymphedema-affected arms was higher than that in arms of healthy normal volunteers or in contralateral nonlymphedema affected arms. Time of venous outflow period of blood flow pulse was lower in lymphedema-affected arms than in healthy normal or lymphedema nonaffected arms. Amplitude of the venous component of blood flow pulse signal was lower in lymphedema-affected arms than in healthy or lymphedema nonaffected arms. Index of venular tone was also lower in lymphedema-affected arms than healthy or lymphedema nonaffected arms. Conclusions Both arterial and venous components may be altered in the lymphedema-affected arms when compared to healthy normal arms and contralateral arms in the breast cancer survivors. PMID:21417765

  14. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    PubMed

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  15. The spectrum of aseptic central nervous system infections in southern Germany - demographic, clinical and laboratory findings.

    PubMed

    Kaminski, M; Grummel, V; Hoffmann, D; Berthele, A; Hemmer, B

    2017-08-01

    Aseptic infections of the central nervous system (CNS) are frequently observed in Germany. However, no study has systematically addressed the spectrum of aseptic CNS infections in Germany. Data on 191 adult patients diagnosed from January 2007 to December 2014 with aseptic meningitis or encephalitis/meningoencephalitis at our hospital were collected by chart review and analyzed for demographic, clinical and laboratory findings. Patients were stratified according to the causative virus and findings were compared between groups. In our cohort, meningitis was caused in 36% by enterovirus (EV), 15% by herpes simplex virus (HSV), 12% by varicella zoster virus (VZV) and 5% by tick borne encephalitis (TBE). Encephalitis/meningoencephalitis was caused in 13% by HSV, 13% by VZV, and three out of 11 tested patients were positive for TBE. The highest incidence of EV infections was between 25 and 35 years and of HSV infections between 30 and 60 years. VZV infections had a bimodal distribution peaking below 30 and above 70 years. VZV and EV infections were more frequently observed during summer, whereas HSV infections showed no seasonal preference. Inflammatory changes in cerebrospinal fluid (CSF) were highest in HSV and lowest in EV infections. Polymerase chain reaction tests for HSV, VZV and EV in CSF and TBE serology determined the causative virus in over 60% of tested patients. The age of affected patients, seasonal distribution, disease course and inflammatory changes in CSF differ between groups of patients affected by the most common viral infections. © 2017 EAN.

  16. Development and Preliminary In vitro Evaluation of Nanomicelles Laden In situ Gel of Dexamethasone for Ophthalmic Delivery

    NASA Astrophysics Data System (ADS)

    Chowdhury, Pallabita

    In our previous work we developed and characterized 0.1% dexamethasone mixed nanomicelles (DMN). DMN were prepared using surfactants polyoxyl 40 stearate (P40S) and polysorbate 80 (P80), which are approved by the FDA for ocular use. The present study builds on the previous work by developing and evaluating nanomicelles laden in situ gel of 0.1% dexamethasone (DMN-ISG) with potential for treating anterior segment eye inflammations. DMN-ISG was prepared by mixing the basic 2X formulation of DMN with appropriate concentrations of gellan gum, mannitol, benzododecinium bromide and tromethamine. DMN-ISG was characterized for gelation, viscosity, transparency, morphology using Transmission Electron Microscopy (TEM), thermoanalysis using Differential Scanning Calorimetry (DSC), in vitro drug release and sterility. DMN prepared with an optimized composition of P40S/P80=7/3 by weight were used in the preparation of DMN-ISG. TEM image of DMN-ISG showed the presence of dexamethasone nanomicelles in the size range between 20-40 nm entrapped in the gel structure. More than 50% of the drug was released from DMN-ISG in the first few hours and the remaining drug was released in a sustained manner for up to 30 h. Aseptically prepared DMN-ISG formulation remained sterile for up to 14 days. The preliminary findings of our investigation suggest that DMN-ISG has the potential for use in treating anterior segment eye inflammations. Further in vivo evaluation is warranted.

  17. Peristaltic pump noise: A nemesis conquered

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burns, D.A.

    1994-12-31

    Continuous-flow analyzers (CFA), and especially Segmented Flow Analyzers (SFA), typically employ peristaltic pumps to generate a carrier stream and add reagents thereto. The resulting pump {open_quotes}noise{close_quotes} usually limits precision, and is generally deemed unavoidable. Although the problem is partially solved by hydraulic debubbling, most modern instruments employ bubble thru the flow-cell (BTTFC) technology and electronic debubbling. The authors have developed an algorithm that can significantly reduce this source of noise, even when the individual segments in the SFA stream are of varying volumes and/or concentrations. It does this, without any modifications to the pump, by examining each individual segment asmore » it passes thru the flowcell. The Alpkem model 304 multichannel pump, for example, can be set to produce 90 bubbles/minutes (and therefore 90 segments/minute), so one has 667 msec in which to gather sufficient information to identify a {open_quotes}bad{close_quotes} segment and modify its value. This hardware includes a Hewlett Packard model 8452A diode array spectrophotometer fitted with fiber optics leading to/from a flowcell (5 mm path length X 1mm ID). Each segment remains in the flowcell 300-500 msec. With a data sampling rate of 10/sec (100 msec integration time), the authors can acquire 3-5 intensity values for each segment and convert these to absorbance values. The software to perform all this was written in QuickBASIC 4.5 and incorporates a few routines from Hewlett Packard`s library. The program will be described in some detail so that analytical chemists who use BTTFC can obtain higher precision.« less

  18. Improved Segmented-Flow Tracer-Monitored Titration for Automated Measurement of Total Alkalinity in Seawater

    NASA Astrophysics Data System (ADS)

    Spaulding, R. S.; Hales, B.; Beck, J. C.; Degrandpre, M. D.

    2008-12-01

    The four measurable inorganic carbon parameters commonly measured as part of oceanic carbon cycle studies are total dissolved inorganic carbon (DIC), total alkalinity (AT), hydrogen ion concentration (pH) and partial pressure of CO2 (pCO2). AT determination is critical for anthropogenic CO2 inventory calculations and for quantifying CaCO3 saturation. Additionally, measurement of AT in combination with one other carbonate parameter can be used to describe the inorganic carbon equilibria. Current methods for measuring AT require calibrated volumetric flasks and burettes, gravimetry, or precise flow measurements. These methods also require analysis times of ˜15 min and sample volumes of ˜200 mL, and sample introduction is not automated, resulting in labor-intensive measurements and low temporal resolution. The Tracer Monitored Titration (TMT) system was previously developed at the University of Montana for AT measurements. The TMT is not dependent on accurate gravimetric, volumetric or flow rate measurements because it relies on a pH-sensitive indicator (tracer) to track the amount of titrant added to the sample. Sample and a titrant-indicator mixture are mechanically stirred in an optical flow cell and pH is calculated using the indicator equilibrium constant and the spectrophotometrically determined concentrations of the acid and base forms of the indicator. AT is then determined using these data in a non-linear least squares regression of the AT mass and proton balances. The precision and accuracy of the TMT are 2 and 4 micromol per kg in 16 min using 110-mL of sample. The TMT is dependent on complete mixing of titrant with the sample and accurate absorbance measurements. We have developed the segmented-flow TMT (SF- TMT) to improve on these aspects and decrease sample analysis time. The TMT uses segmented flow instead of active mixing and a white LED instead of a tungsten-halogen light source. Air is added to the liquid flow stream, producing segments of liquid separated by air bubbles. Because liquid is not transferred between flow segments, there is rapid flushing which reduces sample volume to <10 mL. Additionally, the slower movement of liquid at the tube walls compared to that at the tube center creates circulation within each liquid segment, mixing the sample and eliminating the need for mechanical stirring. The white LED has higher output at the wavelengths of interest, thus improving the precision of absorbance measurements. These improvements result in a faster, simpler method for measuring AT.

  19. [Pilot plant for microbiological synthesis. Engineer and technological aspects].

    PubMed

    Lukanin, A V

    2007-01-01

    A biotechnological pilot plant (National Research Centre of Antibiotics) and its technical potentialities in production of various biosynthetic products are described. Some engineer and technological aspects of the fermentation equipment and particularly sterilization of the media and apparatus, fermentation broth aeration under sterile conditions and control of biosynthesis technological parameters (t degrees, pO2, P, pH, foaming, etc.) are considered. The pilot plant is designed for fermentation processes under aseptic conditions with the use practically of any object, from bacteria to tissue cultures.

  20. Vasopressin-induced constriction of the isolated rat occipital artery is segment-dependent

    PubMed Central

    Chelko, Stephen P.; Schmiedt, Chad W.; Lewis, Tristan H.; Lewis, Stephen J.; Robertson, Tom P.

    2014-01-01

    Background Circulating factors delivered to the nodose ganglion (NG) by the occipital artery (OA) have shown to affect vagal afferent activity, and thus the contractile state of the OA may influence blood flow to the NG. Methods OA were isolated and bisected into proximal and distal segments, relative to the external carotid artery. Results Bisection, highlighted stark differences between maximal contractile responses and OA sensitivity. Specifically, maximum responses to vasopressin and the V1 receptor agonist, were significantly higher in distal than proximal segments. Distal segments were significantly more sensitive to 5-HT and the 5-HT2 receptor agonist than proximal segments. AT2, V2 and 5-HT1B/1D receptor agonists did not elicit vascular responses. Additionally, AT1 receptor agonists elicited mild, yet not significantly different maximal responses between segments. Conclusion The results of this study are consistent with contractile properties of rat OA being mediated via AT1, V1 and 5-HT2 receptors, and are dependent upon the OA segment. Furthermore, vasopressin-induced constriction of the OA, regardless of a bolus dose or a first and second concentration response curve retained this unique segmental difference and therefore we hypothesize this may be a pathophysiological response in the regulation of blood flow through the OA. PMID:24192548

  1. Histopathology of aseptic necrosis of the femoral head in sickle cell disease.

    PubMed

    Mukisi-Mukaza, Martin; Gomez-Brouchet, Anne; Donkerwolcke, Monique; Hinsenkamp, Maurice; Burny, Franz

    2011-08-01

    This study compares the histopathology of bone biopsies from patients suffering from sickle cell anaemia (homozygote SS) to heterozygote patients (SA) and homozygotes with aseptic osteonecrosis (AA). The sensitivity to bacterial infection of sickle cell patients raises the question of the aetiology of sepsis in the onset of the necrosis. To our knowledge this study is the first to analyse the histopathology of osteonecrosis of the femoral head, at its early stages, in sickle cell anaemia. At the University Hospital of Pointe-à-Pitre, from 1994 to 2007, 38 bone biopsies were obtained from adult patients with avascular necrosis of the femoral head at the time of a core decompression procedure (SS, SC: 27; AS: 5; AA: 6). The histology of the biopsies confirmed the necrosis; all bacteriological cultures were negative. Patients displaying one S gene (SS, SC, AS) compared to homozygote subjects (AA) showed a significant increase of a nonspecific inflammatory granulomatosis (p = 0.003). No relationship was observed between the radiological stages and the histology whatever the genotype (p = 0.1). Inflammatory histopathology without sepsis or advanced alteration characterises the early stages of sickle cell necrosis. This inflammatory process is absent in idiopathic avascular necrosis.

  2. Vessel segmentation in 4D arterial spin labeling magnetic resonance angiography images of the brain

    NASA Astrophysics Data System (ADS)

    Phellan, Renzo; Lindner, Thomas; Falcão, Alexandre X.; Forkert, Nils D.

    2017-03-01

    4D arterial spin labeling magnetic resonance angiography (4D ASL MRA) is a non-invasive and safe modality for cerebrovascular imaging procedures. It uses the patient's magnetically labeled blood as intrinsic contrast agent, so that no external contrast media is required. It provides important 3D structure and blood flow information but a sufficient cerebrovascular segmentation is important since it can help clinicians to analyze and diagnose vascular diseases faster, and with higher confidence as compared to simple visual rating of raw ASL MRA images. This work presents a new method for automatic cerebrovascular segmentation in 4D ASL MRA images of the brain. In this process images are denoised, corresponding image label/control image pairs of the 4D ASL MRA sequences are subtracted, and temporal intensity averaging is used to generate a static representation of the vascular system. After that, sets of vessel and background seeds are extracted and provided as input for the image foresting transform algorithm to segment the vascular system. Four 4D ASL MRA datasets of the brain arteries of healthy subjects and corresponding time-of-flight (TOF) MRA images were available for this preliminary study. For evaluation of the segmentation results of the proposed method, the cerebrovascular system was automatically segmented in the high-resolution TOF MRA images using a validated algorithm and the segmentation results were registered to the 4D ASL datasets. Corresponding segmentation pairs were compared using the Dice similarity coefficient (DSC). On average, a DSC of 0.9025 was achieved, indicating that vessels can be extracted successfully from 4D ASL MRA datasets by the proposed segmentation method.

  3. Energy flow during Olympic weight lifting.

    PubMed

    Garhammer, J

    1982-01-01

    Data obtained from 16-mm film of world caliber Olympic weight lifters performing at major competitions were analyzed to study energy changes during body segment and barbell movements, energy transfer to the barbell, and energy transfer between segments during the lifting movements contested. Determination of barbell and body segment kinematics and use of rigid-link modeling and energy flow techniques permitted the calculation of segment energy content and energy transfer between segments. Energy generation within and transfer to and from segments were determined at 0.04-s intervals by comparing mechanical energy changes of a segment with energy transfer at the joints, calculated from the scalar product of net joint force with absolute joint velocity, and the product of net joint torque due to muscular activity with absolute segment angular velocity. The results provided a detailed understanding of the magnitude and temporal input of energy from dominant muscle groups during a lift. This information also provided a means of quantifying lifting technique. Comparison of segment energy changes determined by the two methods were satisfactory but could likely be improved by employing more sophisticated data smoothing methods. The procedures used in this study could easily be applied to weight training and rehabilitative exercises to help determine their efficacy in producing desired results or to ergonomic situations where a more detailed understanding of the demands made on the body during lifting tasks would be useful.

  4. Vasopressin-induced constriction of the isolated rat occipital artery is segment dependent.

    PubMed

    Chelko, Stephen P; Schmiedt, Chad W; Lewis, Tristan H; Lewis, Stephen J; Robertson, Tom P

    2013-01-01

    Circulating factors delivered to the nodose ganglion (NG) by the occipital artery (OA) have been shown to affect vagal afferent activity, and thus the contractile state of the OA may influence blood flow to the NG. OA were isolated and bisected into proximal and distal segments relative to the external carotid artery. Bisection highlighted stark differences between maximal contractile responses and OA sensitivity. Specifically, maximum responses to vasopressin and the V1 receptor agonist were significantly higher in distal than proximal segments. Distal segments were significantly more sensitive to 5-hydroxytryptamine (5-HT) and the 5-HT2 receptor agonist than proximal segments. Angiotensin II (AT)2, V2 and 5-HT(1B/1D) receptor agonists did not elicit vascular responses. Additionally, AT1 receptor agonists elicited mild, yet not significantly different maximal responses between segments. The results of this study are consistent with contractile properties of rat OA being mediated via AT1, V1 and 5-HT2 receptors and dependent upon the OA segment. Furthermore, vasopressin-induced constriction of the OA, regardless of a bolus dose or a first and second concentration-response curve, retained this unique segmental difference. We hypothesize that these segmental differences may be important in the regulation of blood flow through the OA in health and disease. © 2013 S. Karger AG, Basel.

  5. Solving systems of linear equations by GPU-based matrix factorization in a Science Ground Segment

    NASA Astrophysics Data System (ADS)

    Legendre, Maxime; Schmidt, Albrecht; Moussaoui, Saïd; Lammers, Uwe

    2013-11-01

    Recently, Graphics Cards have been used to offload scientific computations from traditional CPUs for greater efficiency. This paper investigates the adaptation of a real-world linear system solver, which plays a central role in the data processing of the Science Ground Segment of ESA's astrometric Gaia mission. The paper quantifies the resource trade-offs between traditional CPU implementations and modern CUDA based GPU implementations. It also analyses the impact on the pipeline architecture and system development. The investigation starts from both a selected baseline algorithm with a reference implementation and a traditional linear system solver and then explores various modifications to control flow and data layout to achieve higher resource efficiency. It turns out that with the current state of the art, the modifications impact non-technical system attributes. For example, the control flow of the original modified Cholesky transform is modified so that locality of the code and verifiability deteriorate. The maintainability of the system is affected as well. On the system level, users will have to deal with more complex configuration control and testing procedures.

  6. Aseptic necrosis of the femoral head after pregnancy: a case report.

    PubMed

    Nassar, Kawtar; Rachidi, Wafae; Janani, Saadia; Mkinsi, Ouafa

    2016-01-01

    A documented case of beginning aseptic necrosis of the femoral head associated with pregnancy together with a review of the literature about this rare complication of pregnancy is presented. The known risk factors of osteonecrosis are; steroid use, alcoholism, organ transplantation, especially after kidney transplant or bone marrow transplantation bone, systemic lupus erythematosus, dyslipidemia especially hypertriglyceridemia, dysbaric decompression sickness, drepanocytosis and Gaucher's disease. Among the less established factors, we mention procoagulations abnormalities, HIV infection, chemotherapy. We report a case of osteonecrosis of femoral head after pregnancy.

  7. A multiscale Markov random field model in wavelet domain for image segmentation

    NASA Astrophysics Data System (ADS)

    Dai, Peng; Cheng, Yu; Wang, Shengchun; Du, Xinyu; Wu, Dan

    2017-07-01

    The human vision system has abilities for feature detection, learning and selective attention with some properties of hierarchy and bidirectional connection in the form of neural population. In this paper, a multiscale Markov random field model in the wavelet domain is proposed by mimicking some image processing functions of vision system. For an input scene, our model provides its sparse representations using wavelet transforms and extracts its topological organization using MRF. In addition, the hierarchy property of vision system is simulated using a pyramid framework in our model. There are two information flows in our model, i.e., a bottom-up procedure to extract input features and a top-down procedure to provide feedback controls. The two procedures are controlled simply by two pyramidal parameters, and some Gestalt laws are also integrated implicitly. Equipped with such biological inspired properties, our model can be used to accomplish different image segmentation tasks, such as edge detection and region segmentation.

  8. Segmentation Using Multispectral Adaptive Contours

    DTIC Science & Technology

    2004-02-29

    Geometry, University of Toronto Press, 1959. 13. R . Malladi , J. Sethian, “Image Processing via Level Set Curvature Flow,” National Academy of Science, vol...92, pp. 7046, 1995. 14. R . Malladi , J. Sethian, C. Vemuri, "Shape Modeling with Front Propagation: a Level Set Approach," IEEE Transactions on...boundary-based active contour models are reviewed in this report; geometric active contours proposed by Caselles et al. [2] and by Malladi and Sethian [13

  9. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    PubMed

    Dunet, Vincent; Klein, Ran; Allenbach, Gilles; Renaud, Jennifer; deKemp, Robert A; Prior, John O

    2016-06-01

    Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.

  10. Steam cooling system for a gas turbine

    DOEpatents

    Wilson, Ian David; Barb, Kevin Joseph; Li, Ming Cheng; Hyde, Susan Marie; Mashey, Thomas Charles; Wesorick, Ronald Richard; Glynn, Christopher Charles; Hemsworth, Martin C.

    2002-01-01

    The steam cooling circuit for a gas turbine includes a bore tube assembly supplying steam to circumferentially spaced radial tubes coupled to supply elbows for transitioning the radial steam flow in an axial direction along steam supply tubes adjacent the rim of the rotor. The supply tubes supply steam to circumferentially spaced manifold segments located on the aft side of the 1-2 spacer for supplying steam to the buckets of the first and second stages. Spent return steam from these buckets flows to a plurality of circumferentially spaced return manifold segments disposed on the forward face of the 1-2 spacer. Crossover tubes couple the steam supply from the steam supply manifold segments through the 1-2 spacer to the buckets of the first stage. Crossover tubes through the 1-2 spacer also return steam from the buckets of the second stage to the return manifold segments. Axially extending return tubes convey spent cooling steam from the return manifold segments to radial tubes via return elbows.

  11. Rotary magnetic heat pump

    DOEpatents

    Kirol, Lance D.

    1988-01-01

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation.

  12. Rotary magnetic heat pump

    DOEpatents

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holcomb, R.T.; Moore, J.G.; Lipman, P.W.

    The GLORIA long-range sonar imaging system has revealed fields of large lava flows in the Hawaiian Trough east and south of Hawaii in water as deep as 5.5 km. Flows in the most extensive field (110 km long) have erupted from the deep submarine segment of Kilauea's east rift zone. Other flows have been erupted from Loihi and Mauna Loa. This discovery confirms a suspicion, long held from subaerial studies, that voluminous submarine flows are erupted from Hawaiian volcanoes, and it supports an inference that summit calderas repeatedly collapse and fill at intervals of centuries to millenia owing to voluminousmore » eruptions. These extensive flows differ greatly in form from pillow lavas found previously along shallower segments of the rift zones; therefore, revision of concepts of volcano stratigraphy and structure may be required.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Zhiming; Abdelaziz, Omar; Qu, Ming

    This paper introduces a first-order physics-based model that accounts for the fundamental heat and mass transfer between a humid-air vapor stream on feed side to another flow stream on permeate side. The model comprises a few optional submodels for membrane mass transport; and it adopts a segment-by-segment method for discretizing heat and mass transfer governing equations for flow streams on feed and permeate sides. The model is able to simulate both dehumidifiers and energy recovery ventilators in parallel-flow, cross-flow, and counter-flow configurations. The predicted tresults are compared reasonably well with the measurements. The open-source codes are written in C++. Themore » model and open-source codes are expected to become a fundament tool for the analysis of membrane-based dehumidification in the future.« less

  15. SAR operational aspects

    NASA Astrophysics Data System (ADS)

    Holmdahl, P. E.; Ellis, A. B. E.; Moeller-Olsen, P.; Ringgaard, J. P.

    1981-12-01

    The basic requirements of the SAR ground segment of ERS-1 are discussed. A system configuration for the real time data acquisition station and the processing and archive facility is depicted. The functions of a typical SAR processing unit (SPU) are specified, and inputs required for near real time and full precision, deferred time processing are described. Inputs and the processing required for provision of these inputs to the SPU are dealt with. Data flow through the systems, and normal and nonnormal operational sequence, are outlined. Prerequisites for maintaining overall performance are identified, emphasizing quality control. The most demanding tasks to be performed by the front end are defined in order to determine types of processors and peripherals which comply with throughput requirements.

  16. On the Aerodynamics of Windblast.

    DTIC Science & Technology

    1981-11-13

    streamline pattern that characterizes the cross-flow over two circular-cylindrical body segments in line contact with one another at time t = 0. That is, at...over the limbs of the ejection seat occupant. Note that MC may vary over different portions of the body that intercept the flow at different angles a...dimensional, rectilinear situation, one may estimate the kinematics of the ensuing motion of a body segment of mass Ms, subjected to the force

  17. A Tracker for Broken and Closely-Spaced Lines

    DTIC Science & Technology

    1997-10-01

    to combine the current level flow estimate and the previous level flow estimate. However, the result is still not good enough for some reasons. First...geometric attributes are not good enough to discriminate line segments, when they are crowded, parallel and closely-spaced to each other. On the other...level information [10]. Still, it is not good at dealing with closely-spaced line segments. Because it requires a proper size of square neighborhood to

  18. Scale model test results of several STOVL ventral nozzle concepts

    NASA Technical Reports Server (NTRS)

    Meyer, B. E.; Re, R. J.; Yetter, J. A.

    1991-01-01

    Short take-off and vertical landing (STOVL) ventral nozzle concepts are investigated by means of a static cold flow scale model at a NASA facility. The internal aerodynamic performance characteristics of the cruise, transition, and vertical lift modes are considered for four ventral nozzle types. The nozzle configurations examined include those with: butterfly-type inner doors and vectoring exit vanes; circumferential inner doors and thrust vectoring vanes; a three-port segmented version with circumferential inner doors; and a two-port segmented version with cylindrical nozzle exit shells. During the testing, internal and external pressure is measured, and the thrust and flow coefficients and resultant vector angles are obtained. The inner door used for ventral nozzle flow control is found to affect performance negatively during the initial phase of transition. The best thrust performance is demonstrated by the two-port segmented ventral nozzle due to the elimination of the inner door.

  19. Measurement and prediction of flow through a replica segment of a mildly atherosclerotic coronary artery of man

    NASA Technical Reports Server (NTRS)

    Back, L. H.; Radbill, J. R.; Cho, Y. I.; Crawford, D. W.

    1986-01-01

    Pressure distributions were measured along a hollow vascular axisymmetric replica of a segment of the left circumflex coronary artery of man with mildly atherosclerotic diffuse disease. A large range of physiological Reynolds numbers from about 60 to 500, including hyperemic response, was spanned in the flows investigation using a fluid simulating blood kinematic viscosity. Predicted pressure distributions from the numerical solution of the Navier-Stokes equations were similar in trend and magnitude to the measurements. Large variations in the predicted velocity profiles occurred along the lumen. The influence of the smaller scale multiple flow obstacles along the wall (lesion variations) led to sharp spikes in the predicted wall shear stresses. Reynolds number similarity was discussed, and estimates of what time averaged in vivo pressure drop and shear stress might be were given for a vessel segment.

  20. Legal, ethical, and procedural bases for the use of aseptic techniques to implant electronic devices

    USGS Publications Warehouse

    Mulcahy, Daniel M.

    2013-01-01

    The popularity of implanting electronic devices such as transmitters and data loggers into captive and free-ranging animals has increased greatly in the past two decades. The devices have become smaller, more reliable, and more capable (Printz 2004; Wilson and Gifford 2005; Metcalfe et al. 2012). Compared with externally mounted devices, implanted devices are largely invisible to external viewers such as tourists and predators; exist in a physically protected, thermally stable environment in mammals and birds; and greatly reduce drag and risk of entanglement. An implanted animal does not outgrow its device or attachment method as can happen with collars and harnesses, which allows young animals to be more safely equipped. However, compared with mounting external devices, implantation requires greater technical ability to perform the necessary anesthesia, analgesia, and surgery. More than 83% of publications in the 1990s that used radiotelemetry on animals assumed that there were no adverse effects on the animal (Godfrey and Bryant 2003). It is likely that some studies using implanted electronic devices have not been published due to a high level of unexpected mortality or to aberrant behavior or disappearance of the implanted animals, a phenomenon known as the “file drawer” problem (Rosenthal 1979; Scargle 2000). The near absence of such studies from the published record may be providing a false sense of security that procedures being used are more innocuous than they actually are. Similarly, authors sometimes state that it was unlikely that device implantation was problematic because study animals appeared to behave normally, or authors state that previous investigators used the same technique and saw no problems. Such statements are suppositions if no supporting data are provided or if the animals were equipped because there was no other way to follow their activity. Moreover, such suppositions ignore other adverse effects that affect behavior indirectly, and animals often mask the signs of infection to avoid attracting predators (Wobeser 2006). Guidance specific to sterilization of electronic devices for implantation is limited in the wildlife record (Burger et al. 1994; Mulcahy 2003). Few biologists have been formally trained in aseptic technique, but most biologists know that electronic devices should be treated in some way to reduce the chance for infection of the host animal by bacteria, viruses, parasites, and fungi. Most biologists (73%) who implant devices into fishes believe aseptic techniques are important (Wagner and Cooke 2005). However, I maintain that many biologists find it difficult to place the concept of asepsis into practice in their work because of confusion about what constitutes aseptic technique, a lack of surgical knowledge and training, the perception of increased costs, or the belief that aseptic surgeries are impractical or unnecessary for their application. Some have even argued that, while compromising surgical techniques in the field might result in complications or mortalities, the money saved would allow for a compensatory increase in sample size (Anderson and Talcott 2006). In this paper I define aseptic surgical techniques, document the legal and professional guidance for performing aseptic surgeries on wild animals, and present options for sterilizing electronic devices and surgical instruments for field use.

  1. Semi-automatized segmentation method using image-based flow cytometry to study sperm physiology: the case of capacitation-induced tyrosine phosphorylation.

    PubMed

    Matamoros-Volante, Arturo; Moreno-Irusta, Ayelen; Torres-Rodriguez, Paulina; Giojalas, Laura; Gervasi, María G; Visconti, Pablo E; Treviño, Claudia L

    2018-02-01

    Is image-based flow cytometry a useful tool to study intracellular events in human sperm such as protein tyrosine phosphorylation or signaling processes? Image-based flow cytometry is a powerful tool to study intracellular events in a relevant number of sperm cells, which enables a robust statistical analysis providing spatial resolution in terms of the specific subcellular localization of the labeling. Sperm capacitation is required for fertilization. During this process, spermatozoa undergo numerous physiological changes, via activation of different signaling pathways, which are not completely understood. Classical approaches for studying sperm physiology include conventional microscopy, flow cytometry and Western blotting. These techniques present disadvantages for obtaining detailed subcellular information of signaling pathways in a relevant number of cells. This work describes a new semi-automatized analysis using image-based flow cytometry which enables the study, at the subcellular and population levels, of different sperm parameters associated with signaling. The increase in protein tyrosine phosphorylation during capacitation is presented as an example. Sperm cells were isolated from seminal plasma by the swim-up technique. We evaluated the intensity and distribution of protein tyrosine phosphorylation in sperm incubated in non-capacitation and capacitation-supporting media for 1 and 18 h under different experimental conditions. We used an antibody against FER kinase and pharmacological inhibitors in an attempt to identify the kinases involved in protein tyrosine phosphorylation during human sperm capacitation. Semen samples from normospermic donors were obtained by masturbation after 2-3 days of sexual abstinence. We used the innovative technique image-based flow cytometry and image analysis tools to segment individual images of spermatozoa. We evaluated and quantified the regions of sperm where protein tyrosine phosphorylation takes place at the subcellular level in a large number of cells. We also used immunocytochemistry and Western blot analysis. Independent experiments were performed with semen samples from seven different donors. Using image analysis tools, we developed a completely novel semi-automatic strategy useful for segmenting thousands of individual cell images obtained using image-based flow cytometry. Contrary to immunofluorescence which relies on the analysis of a limited sperm population and also on the observer, image-based flow cytometry allows for unbiased quantification and simultaneous localization of post-translational changes in an extended sperm population. Interestingly, important data can be independently analyzed by looking to the frame of interest. As an example, we evaluated the capacitation-associated increase in tyrosine phosphorylation in sperm incubated in non-capacitation and capacitation-supporting media for 1 and 18 h. As previously reported, protein tyrosine phosphorylation increases in a time-depending manner, but our method revealed that this increase occurs differentially among distinct sperm segments. FER kinase is reported to be the enzyme responsible for the increase in protein tyrosine phosphorylation in mouse sperm. Our Western blot analysis revealed for the first time the presence of this enzyme in human sperm. Using our segmentation strategy, we aimed to quantify the effect of pharmacological inhibition of FER kinase and found a marked reduction of protein tyrosine phosphorylation only in the flagellum, which corresponded to the physical localization of FER in human sperm. Our method provides an alternative strategy to study signaling markers associated with capacitation, such as protein tyrosine phosphorylation, in a fast and quantitative manner. None. This is an in vitro study performed under controlled conditions. Chemical inhibitors are not completely specific for the intended target; the possibility of side effects cannot be discarded. Our results demonstrate that the use of image-based flow cytometry is a very powerful tool to study sperm physiology. A large number of cells can be easily analyzed and information at the subcellular level can be obtained. As the segmentation process works with bright-field images, it can be extended to study expression of other proteins of interest using different antibodies or it can be used in living sperm to study intracellular parameters that can be followed using fluorescent dyes sensitive to the parameter of interest (e.g. pH, Ca2+). Therefore, this a versatile method that can be exploited to study several aspects of sperm physiology. This work was supported DGAPA (IN203116 to C. Treviño), Fronteras-CONACyT No. 71 and Eunice Kennedy Shriver National Institute of Child Health and Human Development NIH (RO1 HD38082) to P.E. Visconti and by a Lalor Foundation fellowship to M.G. Gervasi. A. Matamoros is a student of the Maestría en Ciencias Bioquímicas-UNAM program supported by CONACyT (416400) and DGAPA-UNAM. A. Moreno obtained a scholarship from Red MacroUniversidades and L. Giojalas obtained a schloarhip from CONICET and Universidad Nacional de Cordoba. The authors declare there are not conflicts of interest. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email:journals.permissions@oup.com

  2. Assssment and Mapping of the Riverine Hydrokinetic Resource in the Continental United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobson, Paul T.; Ravens, Thomas M.; Cunningham, Keith W.

    2012-12-14

    The U.S. Department of Energy (DOE) funded the Electric Power Research Institute and its collaborative partners, University of Alaska ? Anchorage, University of Alaska ? Fairbanks, and the National Renewable Energy Laboratory, to provide an assessment of the riverine hydrokinetic resource in the continental United States. The assessment benefited from input obtained during two workshops attended by individuals with relevant expertise and from a National Research Council panel commissioned by DOE to provide guidance to this and other concurrent, DOE-funded assessments of water based renewable energy. These sources of expertise provided valuable advice regarding data sources and assessment methodology. Themore » assessment of the hydrokinetic resource in the 48 contiguous states is derived from spatially-explicit data contained in NHDPlus ?a GIS-based database containing river segment-specific information on discharge characteristics and channel slope. 71,398 river segments with mean annual flow greater than 1,000 cubic feet per second (cfs) mean discharge were included in the assessment. Segments with discharge less than 1,000 cfs were dropped from the assessment, as were river segments with hydroelectric dams. The results for the theoretical and technical resource in the 48 contiguous states were found to be relatively insensitive to the cutoff chosen. Raising the cutoff to 1,500 cfs had no effect on estimate of the technically recoverable resource, and the theoretical resource was reduced by 5.3%. The segment-specific theoretical resource was estimated from these data using the standard hydrological engineering equation that relates theoretical hydraulic power (Pth, Watts) to discharge (Q, m3 s-1) and hydraulic head or change in elevation (??, m) over the length of the segment, where ? is the specific weight of water (9800 N m-3): ??? = ? ? ?? For Alaska, which is not encompassed by NPDPlus, hydraulic head and discharge data were manually obtained from Idaho National Laboratory?s Virtual Hydropower Prospector, Google Earth, and U.S. Geological Survey gages. Data were manually obtained for the eleven largest rivers with average flow rates greater than 10,000 cfs and the resulting estimate of the theoretical resource was expanded to include rivers with discharge between 1,000 cfs and 10,000 cfs based upon the contribution of rivers in the latter flow class to the total estimate in the contiguous 48 states. Segment-specific theoretical resource was aggregated by major hydrologic region in the contiguous, lower 48 states and totaled 1,146 TWh/yr. The aggregate estimate of the Alaska theoretical resource is 235 TWh/yr, yielding a total theoretical resource estimate of 1,381 TWh/yr for the continental US. The technically recoverable resource in the contiguous 48 states was estimated by applying a recovery factor to the segment-specific theoretical resource estimates. The recovery factor scales the theoretical resource for a given segment to take into account assumptions such as minimum required water velocity and depth during low flow conditions, maximum device packing density, device efficiency, and flow statistics (e.g., the 5 percentile flow relative to the average flow rate). The recovery factor also takes account of ?back effects? ? feedback effects of turbine presence on hydraulic head and velocity. The recovery factor was determined over a range of flow rates and slopes using the hydraulic model, HEC-RAS. In the hydraulic modeling, presence of turbines was accounted for by adjusting the Manning coefficient. This analysis, which included 32 scenarios, led to an empirical function relating recovery factor to slope and discharge. Sixty-nine percent of NHDPlus segments included in the theoretical resource estimate for the contiguous 48 states had an estimated recovery factor of zero. For Alaska, data on river slope was not readily available; hence, the recovery factor was estimated based on the flow rate alone. Segment-specific estimates of the theoretical resource were multiplied by the corresponding recovery factor to estimate the technically recoverable resource. The resulting technically recoverable resource estimate for the continental United States is 120 TWh/yr.« less

  3. Computerized tongue image segmentation via the double geo-vector flow

    PubMed Central

    2014-01-01

    Background Visual inspection for tongue analysis is a diagnostic method in traditional Chinese medicine (TCM). Owing to the variations in tongue features, such as color, texture, coating, and shape, it is difficult to precisely extract the tongue region in images. This study aims to quantitatively evaluate tongue diagnosis via automatic tongue segmentation. Methods Experiments were conducted using a clinical image dataset provided by the Laboratory of Traditional Medical Syndromes, Shanghai University of TCM. First, a clinical tongue image was refined by a saliency window. Second, we initialized the tongue area as the upper binary part and lower level set matrix. Third, a double geo-vector flow (DGF) was proposed to detect the tongue edge and segment the tongue region in the image, such that the geodesic flow was evaluated in the lower part, and the geo-gradient vector flow was evaluated in the upper part. Results The performance of the DGF was evaluated using 100 images. The DGF exhibited better results compared with other representative studies, with its true-positive volume fraction reaching 98.5%, its false-positive volume fraction being 1.51%, and its false-negative volume fraction being 1.42%. The errors between the proposed automatic segmentation results and manual contours were 0.29 and 1.43% in terms of the standard boundary error metrics of Hausdorff distance and mean distance, respectively. Conclusions By analyzing the time complexity of the DGF and evaluating its performance via standard boundary and area error metrics, we have shown both efficiency and effectiveness of the DGF for automatic tongue image segmentation. PMID:24507094

  4. Computerized tongue image segmentation via the double geo-vector flow.

    PubMed

    Shi, Miao-Jing; Li, Guo-Zheng; Li, Fu-Feng; Xu, Chao

    2014-02-08

    Visual inspection for tongue analysis is a diagnostic method in traditional Chinese medicine (TCM). Owing to the variations in tongue features, such as color, texture, coating, and shape, it is difficult to precisely extract the tongue region in images. This study aims to quantitatively evaluate tongue diagnosis via automatic tongue segmentation. Experiments were conducted using a clinical image dataset provided by the Laboratory of Traditional Medical Syndromes, Shanghai University of TCM. First, a clinical tongue image was refined by a saliency window. Second, we initialized the tongue area as the upper binary part and lower level set matrix. Third, a double geo-vector flow (DGF) was proposed to detect the tongue edge and segment the tongue region in the image, such that the geodesic flow was evaluated in the lower part, and the geo-gradient vector flow was evaluated in the upper part. The performance of the DGF was evaluated using 100 images. The DGF exhibited better results compared with other representative studies, with its true-positive volume fraction reaching 98.5%, its false-positive volume fraction being 1.51%, and its false-negative volume fraction being 1.42%. The errors between the proposed automatic segmentation results and manual contours were 0.29 and 1.43% in terms of the standard boundary error metrics of Hausdorff distance and mean distance, respectively. By analyzing the time complexity of the DGF and evaluating its performance via standard boundary and area error metrics, we have shown both efficiency and effectiveness of the DGF for automatic tongue image segmentation.

  5. A semi-automated volumetric software for segmentation and perfusion parameter quantification of brain tumors using 320-row multidetector computed tomography: a validation study.

    PubMed

    Chae, Soo Young; Suh, Sangil; Ryoo, Inseon; Park, Arim; Noh, Kyoung Jin; Shim, Hackjoon; Seol, Hae Young

    2017-05-01

    We developed a semi-automated volumetric software, NPerfusion, to segment brain tumors and quantify perfusion parameters on whole-brain CT perfusion (WBCTP) images. The purpose of this study was to assess the feasibility of the software and to validate its performance compared with manual segmentation. Twenty-nine patients with pathologically proven brain tumors who underwent preoperative WBCTP between August 2012 and February 2015 were included. Three perfusion parameters, arterial flow (AF), equivalent blood volume (EBV), and Patlak flow (PF, which is a measure of permeability of capillaries), of brain tumors were generated by a commercial software and then quantified volumetrically by NPerfusion, which also semi-automatically segmented tumor boundaries. The quantification was validated by comparison with that of manual segmentation in terms of the concordance correlation coefficient and Bland-Altman analysis. With NPerfusion, we successfully performed segmentation and quantified whole volumetric perfusion parameters of all 29 brain tumors that showed consistent perfusion trends with previous studies. The validation of the perfusion parameter quantification exhibited almost perfect agreement with manual segmentation, with Lin concordance correlation coefficients (ρ c ) for AF, EBV, and PF of 0.9988, 0.9994, and 0.9976, respectively. On Bland-Altman analysis, most differences between this software and manual segmentation on the commercial software were within the limit of agreement. NPerfusion successfully performs segmentation of brain tumors and calculates perfusion parameters of brain tumors. We validated this semi-automated segmentation software by comparing it with manual segmentation. NPerfusion can be used to calculate volumetric perfusion parameters of brain tumors from WBCTP.

  6. Tumor necrosis factor α level in cerebrospinal fluid for bacterial and aseptic meningitis: a diagnostic meta-analysis.

    PubMed

    Lv, S; Zhao, J; Zhang, J; Kwon, S; Han, M; Bian, R; Fu, H; Zhang, Y; Pan, H

    2014-08-01

    In our previous study, tumor necrosis factor α (TNF-α) was identified as an effective target for sepsis patients (Int J Clin Pract, 68, 2014, 520). TNF-α in cerebrospinal fluid (CSF) was also investigated for its utility in the differential diagnosis of bacterial and aseptic meningitis. However, there has been neither definite nor convincing evidence so far. Here the overall diagnostic accuracy of TNF-α in differentiation between bacterial and aseptic meningitis was evaluated through the meta-analysis of diagnostic tests. The sensitivity, specificity and other measures of accuracy were pooled using random effect models. Summary receiver operating characteristic curves were used to assess overall test performance. Publication bias was evaluated using funnel plots, and sensitivity analysis was also introduced. A total of 21 studies involving bacterial meningitis (678) and aseptic meningitis (694) involved a total of 1372 patients. The pooled sensitivity and specificity for the TNF-α test were 0.83 [95% confidence interval (CI) 0.80-0.86, I(2)  = 65.1] and 0.92 (95% CI 0.89-0.94, I(2)  = 61.8), respectively. The positive likelihood ratio was 12.05 (95% CI 7.41-19.60, I(2)  = 36.5), the negative likelihood ratio was 0.17 (95% CI 0.13-0.24, I(2)  = 59.4), and TNF-α was significantly associated with bacterial meningitis, with a diagnostic odds ratio of 49.84 (95% CI 28.53-87.06, I(2)  = 47.9). The overall accuracy of the TNF-α test was very high with the area under the curve 0.9317. Publication bias was absent, and sensitivity analysis suggested that our results were highly stable. Our meta-analysis suggested that TNF-α could be recommended as a useful marker for diagnosis of bacterial meningitis and differential diagnosis between bacterial and aseptic meningitis with high sensitivity and specificity. Thus, hospitals should be encouraged to conduct TNF-α tests in CSF after lumbar puncture. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.

  7. Toscana virus NSs protein promotes degradation of double-stranded RNA-dependent protein kinase.

    PubMed

    Kalveram, Birte; Ikegami, Tetsuro

    2013-04-01

    Toscana virus (TOSV), which is transmitted by Phlebotomus spp. sandflies, is a major etiologic agent of aseptic meningitis and encephalitis in the Mediterranean. Like other members of the genus Phlebovirus of the family Bunyaviridae, TOSV encodes a nonstructural protein (NSs) in its small RNA segment. Although the NSs of Rift Valley fever virus (RVFV) has been identified as an important virulence factor, which suppresses host general transcription, inhibits transcription from the beta interferon promoter, and promotes the proteasomal degradation of double-stranded RNA-dependent protein kinase (PKR), little is known about the functions of NSs proteins encoded by less-pathogenic members of this genus. In this study we report that TOSV is able to downregulate PKR with similar efficiency as RVFV, while infection with the other phleboviruses-i.e., Punta Toro virus, sandfly fever Sicilian virus, or Frijoles virus-has no effect on cellular PKR levels. In contrast to RVFV, however, cellular transcription remains unaffected during TOSV infection. TOSV NSs protein promotes the proteasome-dependent downregulation of PKR and is able to interact with kinase-inactive PKR in infected cells.

  8. Toscana Virus NSs Protein Promotes Degradation of Double-Stranded RNA-Dependent Protein Kinase

    PubMed Central

    Kalveram, Birte

    2013-01-01

    Toscana virus (TOSV), which is transmitted by Phlebotomus spp. sandflies, is a major etiologic agent of aseptic meningitis and encephalitis in the Mediterranean. Like other members of the genus Phlebovirus of the family Bunyaviridae, TOSV encodes a nonstructural protein (NSs) in its small RNA segment. Although the NSs of Rift Valley fever virus (RVFV) has been identified as an important virulence factor, which suppresses host general transcription, inhibits transcription from the beta interferon promoter, and promotes the proteasomal degradation of double-stranded RNA-dependent protein kinase (PKR), little is known about the functions of NSs proteins encoded by less-pathogenic members of this genus. In this study we report that TOSV is able to downregulate PKR with similar efficiency as RVFV, while infection with the other phleboviruses—i.e., Punta Toro virus, sandfly fever Sicilian virus, or Frijoles virus—has no effect on cellular PKR levels. In contrast to RVFV, however, cellular transcription remains unaffected during TOSV infection. TOSV NSs protein promotes the proteasome-dependent downregulation of PKR and is able to interact with kinase-inactive PKR in infected cells. PMID:23325696

  9. Recurrent network dynamics reconciles visual motion segmentation and integration.

    PubMed

    Medathati, N V Kartheek; Rankin, James; Meso, Andrew I; Kornprobst, Pierre; Masson, Guillaume S

    2017-09-12

    In sensory systems, a range of computational rules are presumed to be implemented by neuronal subpopulations with different tuning functions. For instance, in primate cortical area MT, different classes of direction-selective cells have been identified and related either to motion integration, segmentation or transparency. Still, how such different tuning properties are constructed is unclear. The dominant theoretical viewpoint based on a linear-nonlinear feed-forward cascade does not account for their complex temporal dynamics and their versatility when facing different input statistics. Here, we demonstrate that a recurrent network model of visual motion processing can reconcile these different properties. Using a ring network, we show how excitatory and inhibitory interactions can implement different computational rules such as vector averaging, winner-take-all or superposition. The model also captures ordered temporal transitions between these behaviors. In particular, depending on the inhibition regime the network can switch from motion integration to segmentation, thus being able to compute either a single pattern motion or to superpose multiple inputs as in motion transparency. We thus demonstrate that recurrent architectures can adaptively give rise to different cortical computational regimes depending upon the input statistics, from sensory flow integration to segmentation.

  10. Background fluorescence estimation and vesicle segmentation in live cell imaging with conditional random fields.

    PubMed

    Pécot, Thierry; Bouthemy, Patrick; Boulanger, Jérôme; Chessel, Anatole; Bardin, Sabine; Salamero, Jean; Kervrann, Charles

    2015-02-01

    Image analysis applied to fluorescence live cell microscopy has become a key tool in molecular biology since it enables to characterize biological processes in space and time at the subcellular level. In fluorescence microscopy imaging, the moving tagged structures of interest, such as vesicles, appear as bright spots over a static or nonstatic background. In this paper, we consider the problem of vesicle segmentation and time-varying background estimation at the cellular scale. The main idea is to formulate the joint segmentation-estimation problem in the general conditional random field framework. Furthermore, segmentation of vesicles and background estimation are alternatively performed by energy minimization using a min cut-max flow algorithm. The proposed approach relies on a detection measure computed from intensity contrasts between neighboring blocks in fluorescence microscopy images. This approach permits analysis of either 2D + time or 3D + time data. We demonstrate the performance of the so-called C-CRAFT through an experimental comparison with the state-of-the-art methods in fluorescence video-microscopy. We also use this method to characterize the spatial and temporal distribution of Rab6 transport carriers at the cell periphery for two different specific adhesion geometries.

  11. Automatic graph-cut based segmentation of bones from knee magnetic resonance images for osteoarthritis research.

    PubMed

    Ababneh, Sufyan Y; Prescott, Jeff W; Gurcan, Metin N

    2011-08-01

    In this paper, a new, fully automated, content-based system is proposed for knee bone segmentation from magnetic resonance images (MRI). The purpose of the bone segmentation is to support the discovery and characterization of imaging biomarkers for the incidence and progression of osteoarthritis, a debilitating joint disease, which affects a large portion of the aging population. The segmentation algorithm includes a novel content-based, two-pass disjoint block discovery mechanism, which is designed to support automation, segmentation initialization, and post-processing. The block discovery is achieved by classifying the image content to bone and background blocks according to their similarity to the categories in the training data collected from typical bone structures. The classified blocks are then used to design an efficient graph-cut based segmentation algorithm. This algorithm requires constructing a graph using image pixel data followed by applying a maximum-flow algorithm which generates a minimum graph-cut that corresponds to an initial image segmentation. Content-based refinements and morphological operations are then applied to obtain the final segmentation. The proposed segmentation technique does not require any user interaction and can distinguish between bone and highly similar adjacent structures, such as fat tissues with high accuracy. The performance of the proposed system is evaluated by testing it on 376 MR images from the Osteoarthritis Initiative (OAI) database. This database included a selection of single images containing the femur and tibia from 200 subjects with varying levels of osteoarthritis severity. Additionally, a full three-dimensional segmentation of the bones from ten subjects with 14 slices each, and synthetic images with background having intensity and spatial characteristics similar to those of bone are used to assess the robustness and consistency of the developed algorithm. The results show an automatic bone detection rate of 0.99 and an average segmentation accuracy of 0.95 using the Dice similarity index. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Why Do Medial Unicompartmental Knee Arthroplasties Fail Today?

    PubMed

    van der List, Jelle P; Zuiderbaan, Hendrik A; Pearle, Andrew D

    2016-05-01

    Failure rates are higher in medial unicompartmental knee arthroplasty (UKA) than total knee arthroplasty. To improve these failure rates, it is important to understand why medial UKA fail. Because individual studies lack power to show failure modes, a systematic review was performed to assess medial UKA failure modes. Furthermore, we compared cohort studies with registry-based studies, early with midterm and late failures and fixed-bearing with mobile-bearing implants. Databases of PubMed, EMBASE, and Cochrane and annual registries were searched for medial UKA failures. Studies were included when they reported >25 failures or when they reported early (<5 years), midterm (5-10 years), or late failures (>10 years). Thirty-seven cohort studies (4 level II studies and 33 level III studies) and 2 registry-based studies were included. A total of 3967 overall failures, 388 time-dependent failures, and 1305 implant design failures were identified. Aseptic loosening (36%) and osteoarthritis (OA) progression (20%) were the most common failure modes. Aseptic loosening (26%) was most common early failure mode, whereas OA progression was more commonly seen in midterm and late failures (38% and 40%, respectively). Polyethylene wear (12%) and instability (12%) were more common in fixed-bearing implants, whereas pain (14%) and bearing dislocation (11%) were more common in mobile-bearing implants. This level III systematic review identified aseptic loosening and OA progression as the major failure modes. Aseptic loosening was the main failure mode in early years and mobile-bearing implants, whereas OA progression caused most failures in late years and fixed-bearing implants. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Aseptic meningitis outbreak associated with echovirus 30 among high school football players--Los Angeles County, California, 2014.

    PubMed

    Croker, Curtis; Civen, Rachel; Keough, Kathleen; Ngo, Van; Marutani, Amy; Schwartz, Benjamin

    2015-01-02

    On August 4, 2014, the Acute Communicable Disease Control Program of the Los Angeles County Department of Public Health received a report of three aseptic meningitis cases among football players at a county high school. An investigation was conducted to determine the extent of the outbreak, identify potential exposures, and recommend control measures. An outbreak-associated aseptic meningitis case was defined as an illness of any team or family member with onset during July 28-August 11 with 1) cerebrospinal fluid pleocytosis and negative bacterial culture or 2) an emergency department visit with headache, fever, and stiff neck. Ten cases were identified; nine in males, and one in a female; patient ages ranged from 13 to 17 years. All the patients sought care at an emergency department, and five were hospitalized, resulting in 12 total hospital days. All 10 patients have recovered. Eight patients were football players, and two were siblings of football players. The most affected subgroup was the junior varsity football team, with seven cases out of 57 players (attack rate = 12.3%); the relative risk for aseptic meningitis was higher among players who were linemen than among those who were not linemen (relative risk = 5.4 [p = 0.03]). Of the 10 patients, eight tested positive by polymerase chain reaction for enterovirus, and two were not tested. Echovirus testing was performed at the California Viral and Rickettsial Disease Laboratory. Of the eight specimens testing positive for enterovirus, seven tested positive for echovirus 30, and one specimen could not be typed because of insufficient quantity.

  14. Laboratory diagnosis and genetic analysis of a family clustering outbreak of aseptic meningitis due to echovirus 30

    PubMed Central

    Ye, Hongyan; Yan, Juying; Xie, Guoliang; Cui, Dawei; Yu, Fei; Wang, Yiyin; Yang, Xianzhi; Zhou, Fangman; Zhang, Yanjun; Tian, Xueli; Chen, Yu

    2016-01-01

    Echovirus 30 (E30) is a major pathogen associated with aseptic meningitis. In the summer of 2014, a family clustering aseptic meningitis outbreak occurred in urban–rural fringe of Ningbo city in Zhejiang Province in China. To identify the etiologic agent, specimens were tested by cell culture and reverse transcriptase–polymerase chain reaction. Pathogenic examination confirmed that the outbreak is caused by E30. The first case is a 6-year-old child, who studied in kindergarten in local, suffered from headache and fever. Same symptoms appeared in his parents, aunts, and other six relatives continuously. Meanwhile, vomiting occurred in majority of the patients and diarrhea in parts of them. White blood cells in cerebrospinal fluid (CSF) exceeded normal range in all patients. Protein levels in CSF were above normal range in half of the patients. Glucose levels in CSF were within normal range in all patients. We isolated six strains E30 in the stool specimens of patients, and carried out sequencing analysis to VP1 region. Sequencing results showed that 100% sequence identity was seen in both nucleotide and amino acid levels. Phylogenetic analysis discovered that isolate in this study was grouped into sublineage D2 together with sequences isolated from other areas of China in the 2000s and 2010s. Our study is the first family clustering outbreak of aseptic meningitis caused by E30 in Zhejiang Province in China. It is essential to establish an enterovirus molecular surveillance system in China to prevent mass outbreaks in Zhejiang. PMID:27646838

  15. Failure of aseptic revision total knee arthroplasties

    PubMed Central

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-01-01

    Background and purpose In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. Method This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. Results 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). Interpretation In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties. PMID:25267502

  16. Laboratory diagnosis and genetic analysis of a family clustering outbreak of aseptic meningitis due to echovirus 30.

    PubMed

    Zheng, Shufa; Ye, Hongyan; Yan, Juying; Xie, Guoliang; Cui, Dawei; Yu, Fei; Wang, Yiyin; Yang, Xianzhi; Zhou, Fangman; Zhang, Yanjun; Tian, Xueli; Chen, Yu

    2016-09-01

    Echovirus 30 (E30) is a major pathogen associated with aseptic meningitis. In the summer of 2014, a family clustering aseptic meningitis outbreak occurred in urban-rural fringe of Ningbo city in Zhejiang Province in China. To identify the etiologic agent, specimens were tested by cell culture and reverse transcriptase-polymerase chain reaction. Pathogenic examination confirmed that the outbreak is caused by E30. The first case is a 6-year-old child, who studied in kindergarten in local, suffered from headache and fever. Same symptoms appeared in his parents, aunts, and other six relatives continuously. Meanwhile, vomiting occurred in majority of the patients and diarrhea in parts of them. White blood cells in cerebrospinal fluid (CSF) exceeded normal range in all patients. Protein levels in CSF were above normal range in half of the patients. Glucose levels in CSF were within normal range in all patients. We isolated six strains E30 in the stool specimens of patients, and carried out sequencing analysis to VP1 region. Sequencing results showed that 100% sequence identity was seen in both nucleotide and amino acid levels. Phylogenetic analysis discovered that isolate in this study was grouped into sublineage D2 together with sequences isolated from other areas of China in the 2000s and 2010s. Our study is the first family clustering outbreak of aseptic meningitis caused by E30 in Zhejiang Province in China. It is essential to establish an enterovirus molecular surveillance system in China to prevent mass outbreaks in Zhejiang.

  17. From video to computation of biological fluid-structure interaction problems

    NASA Astrophysics Data System (ADS)

    Dillard, Seth I.; Buchholz, James H. J.; Udaykumar, H. S.

    2016-04-01

    This work deals with the techniques necessary to obtain a purely Eulerian procedure to conduct CFD simulations of biological systems with moving boundary flow phenomena. Eulerian approaches obviate difficulties associated with mesh generation to describe or fit flow meshes to body surfaces. The challenges associated with constructing embedded boundary information, body motions and applying boundary conditions on the moving bodies for flow computation are addressed in the work. The overall approach is applied to the study of a fluid-structure interaction problem, i.e., the hydrodynamics of swimming of an American eel, where the motion of the eel is derived from video imaging. It is shown that some first-blush approaches do not work, and therefore, careful consideration of appropriate techniques to connect moving images to flow simulations is necessary and forms the main contribution of the paper. A combination of level set-based active contour segmentation with optical flow and image morphing is shown to enable the image-to-computation process.

  18. Geomorphic Framework to assess changes to aquatic habitat due to flow regulation and channel and floodplain alteration, Cedar River, Washington

    USGS Publications Warehouse

    Gendaszek, Andrew S.; Magirl, Christopher S.; Czuba, Christiana R.; Konrad, Christopher P.; Little, Rand

    2010-01-01

    Flow regulation, bank armoring, and floodplain alteration since the early 20th century have contributed to significant changes in the hydrologic regime and geomorphic processes of the Cedar River in Washington State. The Cedar River originates in the Cascade Range, provides drinking water to the Seattle metropolitan area, and supports several populations of anadromous salmonids. Flow regulation currently has limited influence on the magnitude, duration, and timing of high-flow events, which affect the incubation of salmonids as well as the production and maintenance of their habitat. Unlike structural changes to the channel and floodplain, flow regulation may be modified in the short-term to improve the viability of salmon populations. An understanding of the effects of flow regulation on those populations must be discerned over a range of scales from individual floods that affect the size of individual year classes to decadal high flow regime that influences the amount and quality of channel and off-channel habitat available for spawning and rearing. We present estimates of reach-scale sediment budgets and changes to channel morphology derived from historical orthoimagery, specific gage analyses at four long-term streamflow-gaging stations to quantify trends in aggradation, and hydrologic statistics of the magnitude and duration of peak streamflows. These data suggest a gradient of channel types from unconfined, sediment-rich segments to confined, sediment-poor segments that are likely to have distinct responses to high flows. Particle-size distribution data and longitudinal water surface and streambed profiles for the 56 km downstream of Chester Morse Lake measured in 2010 show the spatial extent of preferred salmonid habitat along the Cedar River. These historical and current data constitute a geomorphic framework to help assess different river management scenarios for salmonid habitat and population viability. PDF version of a presentation on changes to aquatic habitat at the Cedar River in Washington state. Presented at the American Geophysical Union Fall Meeting 2010.

  19. Object Scene Flow

    NASA Astrophysics Data System (ADS)

    Menze, Moritz; Heipke, Christian; Geiger, Andreas

    2018-06-01

    This work investigates the estimation of dense three-dimensional motion fields, commonly referred to as scene flow. While great progress has been made in recent years, large displacements and adverse imaging conditions as observed in natural outdoor environments are still very challenging for current approaches to reconstruction and motion estimation. In this paper, we propose a unified random field model which reasons jointly about 3D scene flow as well as the location, shape and motion of vehicles in the observed scene. We formulate the problem as the task of decomposing the scene into a small number of rigidly moving objects sharing the same motion parameters. Thus, our formulation effectively introduces long-range spatial dependencies which commonly employed local rigidity priors are lacking. Our inference algorithm then estimates the association of image segments and object hypotheses together with their three-dimensional shape and motion. We demonstrate the potential of the proposed approach by introducing a novel challenging scene flow benchmark which allows for a thorough comparison of the proposed scene flow approach with respect to various baseline models. In contrast to previous benchmarks, our evaluation is the first to provide stereo and optical flow ground truth for dynamic real-world urban scenes at large scale. Our experiments reveal that rigid motion segmentation can be utilized as an effective regularizer for the scene flow problem, improving upon existing two-frame scene flow methods. At the same time, our method yields plausible object segmentations without requiring an explicitly trained recognition model for a specific object class.

  20. Semantic image segmentation with fused CNN features

    NASA Astrophysics Data System (ADS)

    Geng, Hui-qiang; Zhang, Hua; Xue, Yan-bing; Zhou, Mian; Xu, Guang-ping; Gao, Zan

    2017-09-01

    Semantic image segmentation is a task to predict a category label for every image pixel. The key challenge of it is to design a strong feature representation. In this paper, we fuse the hierarchical convolutional neural network (CNN) features and the region-based features as the feature representation. The hierarchical features contain more global information, while the region-based features contain more local information. The combination of these two kinds of features significantly enhances the feature representation. Then the fused features are used to train a softmax classifier to produce per-pixel label assignment probability. And a fully connected conditional random field (CRF) is used as a post-processing method to improve the labeling consistency. We conduct experiments on SIFT flow dataset. The pixel accuracy and class accuracy are 84.4% and 34.86%, respectively.

  1. Near-vent chemical processes in a hydrothermal plume: Insights from an integrated study of the Endeavour segment

    NASA Astrophysics Data System (ADS)

    Coogan, L. A.; Attar, A.; Mihaly, S. F.; Jeffries, M.; Pope, M.

    2017-04-01

    The Endeavour segment of the Juan de Fuca mid-ocean ridge is one of the best studied ridge segments and has recently been instrumented as part of Ocean Networks Canada's NEPTUNE cabled observatory. Here we investigate the interaction between high-temperature vent fluids and the overlying water column. A new tow-yo survey found that the average temperature anomaly in the neutrally buoyant plume was ˜0.043°C. The water column temperature and light attenuation anomalies correlate linearly in some areas of the plume but in other areas there is a low light attenuation anomaly relative to the temperature anomaly. This temperature excess is interpreted to reflect heat input through (particle-poor) diffuse flow. If this is correct, about half of the heat flux along the Endeavour segment comes from diffuse flow. Sediment trap and push core data show that the mass accumulation rate of the hydrothermal component of the sediments decreases rapidly with distance from the major vent fields. Large changes in the composition of the hydrothermal component of the sediments also occur with distance from the vent fields. The composition of the sediments indicates (i) sulfides precipitate early and accumulate most rapidly close to the vents with a preferential order of element removal from the plume of Cd > Ag > Cu > Co ˜ Fe; (ii) barite is deposited somewhat further from the vents. Strontium and Pb appear to be strongly incorporated in barite and/or other sulfate minerals; (iii) at most a few percent of the mass of these "insoluble" elements that is vented gets deposited within 1.5 km of the vents.

  2. Segmentation of touching mycobacterium tuberculosis from Ziehl-Neelsen stained sputum smear images

    NASA Astrophysics Data System (ADS)

    Xu, Chao; Zhou, Dongxiang; Liu, Yunhui

    2015-12-01

    Touching Mycobacterium tuberculosis objects in the Ziehl-Neelsen stained sputum smear images present different shapes and invisible boundaries in the adhesion areas, which increases the difficulty in objects recognition and counting. In this paper, we present a segmentation method of combining the hierarchy tree analysis with gradient vector flow snake to address this problem. The skeletons of the objects are used for structure analysis based on the hierarchy tree. The gradient vector flow snake is used to estimate the object edge. Experimental results show that the single objects composing the touching objects are successfully segmented by the proposed method. This work will improve the accuracy and practicability of the computer-aided diagnosis of tuberculosis.

  3. Clinical characteristics and outcomes of the meningitides in systemic lupus erythematosus.

    PubMed

    Baizabal-Carvallo, José Fidel; Delgadillo-Márquez, German; Estañol, Bruno; García-Ramos, Guillermo

    2009-01-01

    The meningitides are rare but well-identified complications in patients with systemic lupus erythematosus (SLE). To determine the clinical characteristics, risk factors, prevalence and outcomes of the meningitides (septic and aseptic) in patients with SLE. From January 1988 to December 2006, we identified patients with SLE and septic or aseptic meningitis. We identified 25 episodes of meningitis in 23 patients with SLE, from a total of 1,411 SLE patients (1.63%); in 15 out of 25 episodes, a microorganism was identified. Mycobacterium tuberculosis, Listeria monocytogenes and Criptococcus neoformans represented the main microorganisms. In 10 episodes, aseptic meningitis was diagnosed. Lymphopenia, steroid use, chronic damage and systemic activity of SLE were frequent in both kinds of meningitis. Although the clinical presentation did not differ significantly, patients with septic meningitis had more residual neurological deficits (p = 0.04). Meningitis was observed in about 1.6% of the patients with SLE; in 40% of the cases, no microorganism could be isolated. A residual neurological deficit was more common in patients with septic meningitis. Copyright (c) 2008 S. Karger AG, Basel.

  4. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff.

    PubMed

    Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S

    2012-05-01

    Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.

  5. Statistical learning of action: the role of conditional probability.

    PubMed

    Meyer, Meredith; Baldwin, Dare

    2011-12-01

    Identification of distinct units within a continuous flow of human action is fundamental to action processing. Such segmentation may rest in part on statistical learning. In a series of four experiments, we examined what types of statistics people can use to segment a continuous stream involving many brief, goal-directed action elements. The results of Experiment 1 showed no evidence for sensitivity to conditional probability, whereas Experiment 2 displayed learning based on joint probability. In Experiment 3, we demonstrated that additional exposure to the input failed to engender sensitivity to conditional probability. However, the results of Experiment 4 showed that a subset of adults-namely, those more successful at identifying actions that had been seen more frequently than comparison sequences-were also successful at learning conditional-probability statistics. These experiments help to clarify the mechanisms subserving processing of intentional action, and they highlight important differences from, as well as similarities to, prior studies of statistical learning in other domains, including language.

  6. The life-cycle of upper-tropospheric jet streams identified with a novel data segmentation algorithm

    NASA Astrophysics Data System (ADS)

    Limbach, S.; Schömer, E.; Wernli, H.

    2010-09-01

    Jet streams are prominent features of the upper-tropospheric atmospheric flow. Through the thermal wind relationship these regions with intense horizontal wind speed (typically larger than 30 m/s) are associated with pronounced baroclinicity, i.e., with regions where extratropical cyclones develop due to baroclinic instability processes. Individual jet streams are non-stationary elongated features that can extend over more than 2000 km in the along-flow and 200-500 km in the across-flow direction, respectively. Their lifetime can vary between a few days and several weeks. In recent years, feature-based algorithms have been developed that allow compiling synoptic climatologies and typologies of upper-tropospheric jet streams based upon objective selection criteria and climatological reanalysis datasets. In this study a novel algorithm to efficiently identify jet streams using an extended region-growing segmentation approach is introduced. This algorithm iterates over a 4-dimensional field of horizontal wind speed from ECMWF analyses and decides at each grid point whether all prerequisites for a jet stream are met. In a single pass the algorithm keeps track of all adjacencies of these grid points and creates the 4-dimensional connected segments associated with each jet stream. In addition to the detection of these sets of connected grid points, the algorithm analyzes the development over time of the distinct 3-dimensional features each segment consists of. Important events in the development of these features, for example mergings and splittings, are detected and analyzed on a per-grid-point and per-feature basis. The output of the algorithm consists of the actual sets of grid-points augmented with information about the particular events, and of the so-called event graphs, which are an abstract representation of the distinct 3-dimensional features and events of each segment. This technique provides comprehensive information about the frequency of upper-tropospheric jet streams, their preferred regions of genesis, merging, splitting, and lysis, and statistical information about their size, amplitude and lifetime. The presentation will introduce the technique, provide example visualizations of the time evolution of the identified 3-dimensional jet stream features, and present results from a first multi-month "climatology" of upper-tropospheric jets. In the future, the technique can be applied to longer datasets, for instance reanalyses and output from global climate model simulations - and provide detailed information about key characteristics of jet stream life cycles.

  7. A microfluidic needle for sampling and delivery of chemical signals by segmented flows

    NASA Astrophysics Data System (ADS)

    Feng, Shilun; Liu, Guozhen; Jiang, Lianmei; Zhu, Yonggang; Goldys, Ewa M.; Inglis, David W.

    2017-10-01

    We have developed a microfluidic needle-like device that can extract and deliver nanoliter samples. The device consists of a T-junction to form segmented flows, parallel channels to and from the needle tip, and seven hydrophilic capillaries at the tip that form a phase-extraction region. The main microchannel is hydrophobic and carries segmented flows of water-in-oil. The hydrophilic capillaries transport the aqueous phase with a nearly zero pressure gradient but require a pressure gradient of 19 kPa for mineral oil to invade and flow through. Using this device, we demonstrate the delivery of nanoliter droplets and demonstrate sampling through the formation of droplets at the tip of our device. During sampling, we recorded the fluorescence intensities of the droplets formed at the tip while varying the concentration of dye outside the tip. We measured a chemical signal response time of approximately 3 s. The linear relationship between the recorded fluorescence intensity of samples and the external dye concentration (10-40 μg/ml) indicates that this device is capable of performing quantitative, real-time measurements of rapidly varying chemical signals.

  8. Flow of two immiscible fluids in a periodically constricted tube: Transitions to stratified, segmented, churn, spray, or segregated flow

    NASA Astrophysics Data System (ADS)

    Fraggedakis, D.; Kouris, Ch.; Dimakopoulos, Y.; Tsamopoulos, J.

    2015-08-01

    We study the flow of two immiscible, Newtonian fluids in a periodically constricted tube driven by a constant pressure gradient. Our volume-of-fluid algorithm is used to solve the governing equations. First, the code is validated by comparing its predictions to previously reported results for stratified and pulsing flow. Then, it is used to capture accurately all the significant topological changes that take place. Initially, the fluids have a core-annular arrangement, which is found to either remain the same or change to a different arrangement depending on the fluid properties, the pressure driving the flow, or the flow geometry. The flow-patterns that appear are the core-annular, segmented, churn, spray, and segregated flow. The predicted scalings near pinching of the core fluid concur with similarity predictions and earlier numerical results [I. Cohen et al., "Two fluid drop snap-off problem: Experiments and theory," Phys. Rev. Lett. 83, 1147-1150 (1999)]. Flow-pattern maps are constructed in terms of the Reynolds and Weber numbers. Our result provides deeper insights into the mechanism of the pattern transitions and is in agreement with previous studies on core-annular flow [Ch. Kouris and J. Tsamopoulos, "Core-annular flow in a periodically constricted circular tube, I. Steady state, linear stability and energy analysis," J. Fluid Mech. 432, 31-68 (2001) and Ch. Kouris et al., "Comparison of spectral and finite element methods applied to the study of interfacial instabilities of the core-annular flow in an undulating tube," Int. J. Numer. Methods Fluids 39(1), 41-73 (2002)], segmented flow [E. Lac and J. D. Sherwood, "Motion of a drop along the centreline of a capillary in a pressure-driven flow," J. Fluid Mech. 640, 27-54 (2009)], and churn flow [R. Y. Bai et al., "Lubricated pipelining—Stability of core annular-flow. 5. Experiments and comparison with theory," J. Fluid Mech. 240, 97-132 (1992)].

  9. Scene segmentation of natural images using texture measures and back-propagation

    NASA Technical Reports Server (NTRS)

    Sridhar, Banavar; Phatak, Anil; Chatterji, Gano

    1993-01-01

    Knowledge of the three-dimensional world is essential for many guidance and navigation applications. A sequence of images from an electro-optical sensor can be processed using optical flow algorithms to provide a sparse set of ranges as a function of azimuth and elevation. A natural way to enhance the range map is by interpolation. However, this should be undertaken with care since interpolation assumes continuity of range. The range is continuous in certain parts of the image and can jump at object boundaries. In such situations, the ability to detect homogeneous object regions by scene segmentation can be used to determine regions in the range map that can be enhanced by interpolation. The use of scalar features derived from the spatial gray-level dependence matrix for texture segmentation is explored. Thresholding of histograms of scalar texture features is done for several images to select scalar features which result in a meaningful segmentation of the images. Next, the selected scalar features are used with a neural net to automate the segmentation procedure. Back-propagation is used to train the feed forward neural network. The generalization of the network approach to subsequent images in the sequence is examined. It is shown that the use of multiple scalar features as input to the neural network result in a superior segmentation when compared with a single scalar feature. It is also shown that the scalar features, which are not useful individually, result in a good segmentation when used together. The methodology is applied to both indoor and outdoor images.

  10. Hydrometry's classical and Innovative methods and tools comparison for Stara river flows at Agios Germanos monitoring station in north-west Greece.

    NASA Astrophysics Data System (ADS)

    Filintas, Agathos, , Dr; Hatzigiannakis, Evagellos, , Dr; Arampatzis, George, , Dr; Ilias, Andreas; Panagopoulos, Andreas, , Dr; Hatzispiroglou, Ioannis

    2015-04-01

    The aim of the present study is a thorough comparison of hydrometry's conventional and innovative methods-tools for river flow monitoring. A case study was conducted in Stara river at Agios Germanos monitoring station (northwest Greece), in order to investigate possible deviations between conventional and innovative methods-tools on river flow velocity and discharge. For this study, two flowmeters were used, which manufac-tured in 2013 (OTT Messtechnik Gmbh, 2013), as follows: a) A conventional propeller flow velocity meter (OTT-Model C2) which is a me-chanical current flow meter with a certification of calibration BARGO, operated with a rod and a relocating device, along with a digital measuring device including an elec-tronic flow calculator, data logger and real time control display unit. The flowmeter has a measurement velocity range 0.025-4.000 m/s. b) An innovative electromagnetic flowmeter (OTT-Model MF pro) which it is con-sisted of a compact and light-weight sensor and a robust handheld unit. Both system components are designed to be attached to conventional wading rods. The electromag-netic flowmeter uses Faraday's Law of electromagnetic induction to measure the process flow. When an electrically conductive fluid flows along the meter, an electrode voltage is induced between a pair of electrodes placed at right angles to the direction of mag-netic field. The electrode voltage is directly proportional to the average fluid velocity. The electromagnetic flowmeter was operated with a rod and relocating device, along with a digital measuring device with various logging and graphical capabilities and vari-ous methods of velocity measurement (ISO/USGS standards). The flowmeter has a measurement velocity range 0.000-6.000 m/s. The river flow data were averaged over a pair measurement of 60+60 seconds and the measured river water flow velocity, depths and widths of the segments were used for the estimation of cross-section's mean flow velocity in each measured segment. Then it was used the mid-section method for the overall discharge calculation of all segments flow area. The cross-section characteristics, the river flow velocity of segments and the mean water flow velocity and discharge total profile were measured, calculated and an-notated respectively. A series of concurrent conventional and innovative (electromag-netic) flow measurements were performed during 2014. The results and statistical analysis showed that Froude number during the measurement period in all cases was Fr<1 which means that the water flow of the Stara river is classified as subcritical flow. The 12 months' study showed various advantages for the elec-tromagnetic sensor that is virtually maintenance-free because there are no moving parts, no calibration was required in practice, and it can be used even in the lowest water ve-locities from 0.000 m/s. Moreover, based on the concurrent hydromeasurements of the Stara River, on the velocity and discharge modelling and the statistical analysis, it was found that there was not a significant statistical difference (α=0.05) between mean velocity measured with a) conventional and b) electromagnetic method which seems to be more accurate in low velocities where a significant statistical difference was found. Acknowledgments Data in this study are collected in the framework of the elaboration of the national water resources monitoring network, supervised by the Special Secretariat for Water-Hellenic Ministry for the Environment and Climate Change. This project is elaborated in the framework of the operational program "Environment and Sustainable Development" which is co-funded by the National Strategic Reference Framework (NSRF) and the Public Investment Program (PIP).

  11. [Early aseptic loosening of the CF 30 femoral stem].

    PubMed

    Kovanda, M; Havlícek, V; Hudec, J

    2007-02-01

    The CF 30 stem in combination with a cementless acetabulum was used at the First Department of Orthopedic Surgery in Brno in the years 1994 to 1995. From the second year following implantation, aseptic stem loosening was recorded. In order to find explanation of this early loosening, the authors, in cooperation with the Institute of Solid Mechanics, Mechatronics and Biomechanics, carried out the stress-strain analysis in a model system. Eighty patients (31 men and 49 women) received a cemented CF30 femoral component in 1994. Of them, 16 patients underwent revision arthroplasty, three died of causes unrelated to the surgery, and four were lost to follow-up. The final clinical and radiographic check-up was carried out in 2001. The results of a comprehensive examination were available in 57 patients with a CF30 stem. The patients were evaluated on the basis of the Harris hip score and anteroposterior radiographs of the hip. X-ray films obtained immediately after surgery and those taken at regular intervals during follow-up were compared. The following characteristics were noted: translucent lines in individual zones along the stem at the cement-bone interface; osteolysis, i. e., non-linear translucent areas, at least 5 mm long, at the cement-bone interface; and subsidence of the femoral component, i. e., migration of the stem distal to the tip of the greater trochanter. The CF 30 stem survival curve showed that aseptic stem loosening occurred from post-implantation year 2, and increased during the following years. At 6 years and 6 months, a total of 16 patients underwent revision surgery, involving reimplantation in 14 and implant removal in 2 patients. Potential causes of aseptic loosening: Polyethylene wear.However, no acetabular loosening was found in this group, although acetabular components are reported to become loose more often than femoral components. By comparison of the stem survival curves for Poldi and CF 30 stems it appeared that, at 6 years and 6 months, the Poldi stem survival curve showed better results. Matt surface finish of the stem. However, the link between the CF 30 stem and cement was so strong that, in all 16 revised hips, the stem was removed together with nearly a complete cement mantle. The authors therefore dismiss this as a cause. Also, in the remaining cases of CF 30 aseptic loosening, which had not been revised, radiographic evidence suggested loosening between bone and cement. The authors did not find any movement of the CF stem in its cement mantle. The stem always fitted in with the cement mantle. Erroneous surgical technique or cementing was unlikely. The procedures were performed by experienced orthopedic surgeons who used the second-generation cementing technique. In patients with a Poldi stem, the first-generation cementing method was used and the proportion of aseptic loosening at 6 years of follow-up was only 4 %. In contrast, loosening in patients with the CF 30 stem was 20 % at 6 years and 6 months postoperatively. Shape of the CF 30 stem with the intention to find a relationship between stem shape and its early aseptic loosening, the authors started cooperation with the Institute of Solid Mechanics, Mechatronics and Biomechanics at the Faculty of Mechanical Engineering, Brno University of Technology. Using the method of finite elements, they carried out the stressstrain analysis in a model system. Stress at the cement-bone interface in the CF 30 stem was higher than in the Poldi stem, and this difference was statistically significant. The authors believe that the more frequent loosening found in patients with the CF 30 stem can be accounted for by its shape. The survival curve for the CF 30 femoral stem did not show good results, and therefore this stem is not recommended for implantation. The authors suggest that a more frequent early aseptic loosening of CF 30 stems may have been caused by its unsuitable shape.

  12. Evaluation of the BioVigilant IMD-A, a novel optical spectroscopy technology for the continuous and real-time environmental monitoring of viable and nonviable particles. Part II. Case studies in environmental monitoring during aseptic filling, intervention assessments, and glove integrity testing in manufacturing isolators.

    PubMed

    Miller, Michael J; Walsh, Michael R; Shrake, Jerry L; Dukes, Randall E; Hill, Daniel B

    2009-01-01

    This paper describes the use of the BioVigilant IMD-A, a real-time and continuous monitoring technology based on optical spectroscopy, to simultaneously and instantaneously detect, size, and enumerate both viable and nonviable particles in a variety of filling and transfer isolator environments during an aseptic fill, transfer of sterilized components, and filling interventions. Continuous monitoring of three separate isolators for more than 16 h and representing more than 28 m3 of air per isolator (under static conditions) yielded a mean viable particle count of zero (0) per cubic meter. Although the mean count per cubic meter was zero, the detection of very low levels of single viable particles was randomly observed in each of these sampling runs. No viable particles were detected during the manual transfer of sterilized components from transfer isolators into a filling isolator, and similar results were observed during an aseptic fill, a filling needle change-out procedure, and during disassembly, movement, and reassembly of a vibrating stopper bowl. During the continuous monitoring of a sample transfer port and a simulated mousehole, no viable particles were detected; however, when the sampling probe was inserted beyond the isolator-room interface, the IMD-A instantaneously detected and enumerated both viable and nonviable particles originating from the surrounding room. Data from glove pinhole studies showed no viable particles being observed, although significant viable particles were immediately detected when the gloves were removed and a bare hand was allowed to introduce microorganisms into the isolator. The IMD-A technology offers the industry an unprecedented advantage over growth-based bioaerosol samplers for monitoring the state of microbiological control in pharmaceutical manufacturing environments, and represents significant progress toward the acceptance of microbiology process analytical technology solutions for the industry.

  13. The fate of the herbicide propanil in plants of the littoral zone of the Three Gorges Reservoir (TGR), China.

    PubMed

    Chen, Zhongli; Schäffer, Andreas

    2016-10-01

    The anti-seasonal hydrology with 30m water fluctuations in the Three Gorges Reservoir (TGR) of China attracts growing environmental and ecological concerns. We investigated the biotransformation of the herbicide propanil in plants dominating in the littoral zone of the TGR by applying the 14 C-ring-labeled herbicide into non-aseptic hydroponic plant systems (Cynodon dactylon, Nelumbo nucifera and Bidens pilosa), aseptic plants (Lemna minor and Lemna gibba) and cell suspension cultures (C. dactylon and L. minor). (1) Propanil absorbed in plants of the hydroponic systems was (12.46±1.63)% of applied radioactivity (AR) (C. dactylon), (52.36±6.38)% (N. nucifera) and (76.55±6.07)% (B. pilosa), respectively. The 14 C-residues in the plant extractable fractions and the corresponding media were confirmed by radio-Thin Layer Chromatography (TLC), radio-High Performance Liquid Chromatography (HPLC) and Gas Chromatography-Electron Ionization Mass Spectrometry (GC-EIMS) as propanil, 3,4-dichloroaniline (DCA) and N-(3,4-dichlorophenyl)-β-d-glucopyranosylamine (Glu-DCA). (2) About 8% of AR was taken up by both aseptic plants, from which 7.0% of AR was extracted and identified also as propanil, DCA and Glu-DCA. (3) Concerning cell suspension cultures, (39.22±9.39)% of AR was absorbed by C. dactylon after 72hr, whereas the accumulated 14 C-propanil by L. minor cell suspension culture amounted to (65.04±1.72)% after 7days. The identified compounds in cell cultures are consistent with those in the tested plants. Most of the pesticide residues in the intact plants were un-extractable, which are recognized as the end of the detoxification process. We therefore consider these plants as suitable for the phytoremediation of the herbicide propanil in the TGR region. Copyright © 2016. Published by Elsevier B.V.

  14. Firearm suppressor having enhanced thermal management for rapid heat dissipation

    DOEpatents

    Moss, William C.; Anderson, Andrew T.

    2014-08-19

    A suppressor is disclosed for use with a weapon having a barrel through which a bullet is fired. The suppressor has an inner portion having a bore extending coaxially therethrough. The inner portion is adapted to be secured to a distal end of the barrel. A plurality of axial flow segments project radially from the inner portion and form axial flow paths through which expanding propellant gasses discharged from the barrel flow through. The axial flow segments have radially extending wall portions that define sections which may be filled with thermally conductive material, which in one example is a thermally conductive foam. The conductive foam helps to dissipate heat deposited within the suppressor during firing of the weapon.

  15. NASA-Ames three-dimensional potential flow analysis system (POTFAN) equation solver code (SOLN) version 1

    NASA Technical Reports Server (NTRS)

    Davis, J. E.; Bonnett, W. S.; Medan, R. T.

    1976-01-01

    A computer program known as SOLN was developed as an independent segment of the NASA-Ames three-dimensional potential flow analysis systems of linear algebraic equations. Methods used include: LU decomposition, Householder's method, a partitioning scheme, and a block successive relaxation method. Due to the independent modular nature of the program, it may be used by itself and not necessarily in conjunction with other segments of the POTFAN system.

  16. Optimal graph based segmentation using flow lines with application to airway wall segmentation.

    PubMed

    Petersen, Jens; Nielsen, Mads; Lo, Pechin; Saghir, Zaigham; Dirksen, Asger; de Bruijne, Marleen

    2011-01-01

    This paper introduces a novel optimal graph construction method that is applicable to multi-dimensional, multi-surface segmentation problems. Such problems are often solved by refining an initial coarse surface within the space given by graph columns. Conventional columns are not well suited for surfaces with high curvature or complex shapes but the proposed columns, based on properly generated flow lines, which are non-intersecting, guarantee solutions that do not self-intersect and are better able to handle such surfaces. The method is applied to segment human airway walls in computed tomography images. Comparison with manual annotations on 649 cross-sectional images from 15 different subjects shows significantly smaller contour distances and larger area of overlap than are obtained with recently published graph based methods. Airway abnormality measurements obtained with the method on 480 scan pairs from a lung cancer screening trial are reproducible and correlate significantly with lung function.

  17. Comparison of results of experimental research with numerical calculations of a model one-sided seal

    NASA Astrophysics Data System (ADS)

    Joachimiak, Damian; Krzyślak, Piotr

    2015-06-01

    Paper presents the results of experimental and numerical research of a model segment of a labyrinth seal for a different wear level. The analysis covers the extent of leakage and distribution of static pressure in the seal chambers and the planes upstream and downstream of the segment. The measurement data have been compared with the results of numerical calculations obtained using commercial software. Based on the flow conditions occurring in the area subjected to calculations, the size of the mesh defined by parameter y+ has been analyzed and the selection of the turbulence model has been described. The numerical calculations were based on the measurable thermodynamic parameters in the seal segments of steam turbines. The work contains a comparison of the mass flow and distribution of static pressure in the seal chambers obtained during the measurement and calculated numerically in a model segment of the seal of different level of wear.

  18. Variational PDE Models in Image Processing

    DTIC Science & Technology

    2002-07-31

    161–168, 2001. [22] T. F. Chan and L. A. Vese. Active contour and segmentation models using ge- ometric PDE’s for medical imaging. Malladi , R . (Ed...continuous “movie” NMOPQ (with some small time step R ), D E >LK @ ’s are the estimated optical flows (i.e. velocity fields) at each moment. During...Bertalmio, G. Sapiro, V. Caselles, and C. Ballester. Image inpainting. Computer Graphics, SIGGRAPH 2000, July, 2000. [6] G. Birkhoff and C. R . De Boor

  19. Disturbed Laminar Blood Flow Vastly Augments Lipoprotein Retention in the Artery Wall: A Key Mechanism Distinguishing Susceptible From Resistant Sites.

    PubMed

    Steffensen, Lasse Bach; Mortensen, Martin Bødtker; Kjolby, Mads; Hagensen, Mette Kallestrup; Oxvig, Claus; Bentzon, Jacob Fog

    2015-09-01

    Atherosclerosis develops initially at branch points and in areas of high vessel curvature. Moreover, experiments in hypercholesterolemic mice have shown that the introduction of disturbed flow in straight, atherosclerosis-resistant arterial segments turns them highly atherosclerosis susceptible. Several biomechanical mechanisms have been proposed, but none has been demonstrated. In the present study, we examined whether a causal link exists between disturbed laminar flow and the ability of the arterial wall to retain lipoproteins. Lipoprotein retention was detected at natural predilection sites of the murine thoracic aorta 18 hours after infusion of fluorescently labeled low-density lipoprotein. To test for causality between blood flow and the ability of these areas to retain lipoproteins, we manipulated blood flow in the straight segment of the common carotid artery using a constrictive collar. Disturbed laminar flow did not affect low-density lipoprotein influx, but increased the ability of the artery wall to bind low-density lipoprotein. Concordantly, disturbed laminar flow led to differential expression of genes associated with phenotypic modulation of vascular smooth muscle cells, increased expression of proteoglycan core proteins associated with lipoprotein retention, and of enzymes responsible for chondroitin sulfate glycosaminoglycan synthesis and sulfation. Blood flow regulates genes associated with vascular smooth muscle cell phenotypic modulation, as well as the expression and post-translational modification of lipoprotein-binding proteoglycan core proteins, and the introduction of disturbed laminar flow vastly augments the ability of a previously resistant, straight arterial segment to retain lipoproteins. © 2015 American Heart Association, Inc.

  20. Comparison of competing segmentation standards for X-ray computed topographic imaging using Lattice Boltzmann techniques

    NASA Astrophysics Data System (ADS)

    Larsen, J. D.; Schaap, M. G.

    2013-12-01

    Recent advances in computing technology and experimental techniques have made it possible to observe and characterize fluid dynamics at the micro-scale. Many computational methods exist that can adequately simulate fluid flow in porous media. Lattice Boltzmann methods provide the distinct advantage of tracking particles at the microscopic level and returning macroscopic observations. While experimental methods can accurately measure macroscopic fluid dynamics, computational efforts can be used to predict and gain insight into fluid dynamics by utilizing thin sections or computed micro-tomography (CMT) images of core sections. Although substantial effort have been made to advance non-invasive imaging methods such as CMT, fluid dynamics simulations, and microscale analysis, a true three dimensional image segmentation technique has not been developed until recently. Many competing segmentation techniques are utilized in industry and research settings with varying results. In this study lattice Boltzmann method is used to simulate stokes flow in a macroporous soil column. Two dimensional CMT images were used to reconstruct a three dimensional representation of the original sample. Six competing segmentation standards were used to binarize the CMT volumes which provide distinction between solid phase and pore space. The permeability of the reconstructed samples was calculated, with Darcy's Law, from lattice Boltzmann simulations of fluid flow in the samples. We compare simulated permeability from differing segmentation algorithms to experimental findings.

  1. Methods for disassembling, replacing and assembling parts of a steam cooling system for a gas turbine

    DOEpatents

    Wilson, Ian D.; Wesorick, Ronald R.

    2002-01-01

    The steam cooling circuit for a gas turbine includes a bore tube assembly supplying steam to circumferentially spaced radial tubes coupled to supply elbows for transitioning the radial steam flow in an axial direction along steam supply tubes adjacent the rim of the rotor. The supply tubes supply steam to circumferentially spaced manifold segments located on the aft side of the 1-2 spacer for supplying steam to the buckets of the first and second stages. Spent return steam from these buckets flows to a plurality of circumferentially spaced return manifold segments disposed on the forward face of the 1-2 spacer. Crossover tubes couple the steam supply from the steam supply manifold segments through the 1-2 spacer to the buckets of the first stage. Crossover tubes through the 1-2 spacer also return steam from the buckets of the second stage to the return manifold segments. Axially extending return tubes convey spent cooling steam from the return manifold segments to radial tubes via return elbows. The bore tube assembly, radial tubes, elbows, manifold segments and crossover tubes are removable from the turbine rotor and replaceable.

  2. Radiation treatment for sterilization of packaging materials

    NASA Astrophysics Data System (ADS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-08-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology.

  3. Numerical Simulation of the Flow over a Segment-Conical Body on the Basis of Reynolds Equations

    NASA Astrophysics Data System (ADS)

    Egorov, I. V.; Novikov, A. V.; Palchekovskaya, N. V.

    2018-01-01

    Numerical simulation was used to study the 3D supersonic flow over a segment-conical body similar in shape to the ExoMars space vehicle. The nonmonotone behavior of the normal force acting on the body placed in a supersonic gas flow was analyzed depending on the angle of attack. The simulation was based on the numerical solution of the unsteady Reynolds-averaged Navier-Stokes equations with a two-parameter differential turbulence model. The solution of the problem was obtained using the in-house solver HSFlow with an efficient parallel algorithm intended for multiprocessor super computers.

  4. Image Segmentation Using Minimum Spanning Tree

    NASA Astrophysics Data System (ADS)

    Dewi, M. P.; Armiati, A.; Alvini, S.

    2018-04-01

    This research aim to segmented the digital image. The process of segmentation is to separate the object from the background. So the main object can be processed for the other purposes. Along with the development of technology in digital image processing application, the segmentation process becomes increasingly necessary. The segmented image which is the result of the segmentation process should accurate due to the next process need the interpretation of the information on the image. This article discussed the application of minimum spanning tree on graph in segmentation process of digital image. This method is able to separate an object from the background and the image will change to be the binary images. In this case, the object that being the focus is set in white, while the background is black or otherwise.

  5. Computer aided segmentation of kidneys using locally shape constrained deformable models on CT images

    NASA Astrophysics Data System (ADS)

    Erdt, Marius; Sakas, Georgios

    2010-03-01

    This work presents a novel approach for model based segmentation of the kidney in images acquired by Computed Tomography (CT). The developed computer aided segmentation system is expected to support computer aided diagnosis and operation planning. We have developed a deformable model based approach based on local shape constraints that prevents the model from deforming into neighboring structures while allowing the global shape to adapt freely to the data. Those local constraints are derived from the anatomical structure of the kidney and the presence and appearance of neighboring organs. The adaptation process is guided by a rule-based deformation logic in order to improve the robustness of the segmentation in areas of diffuse organ boundaries. Our work flow consists of two steps: 1.) a user guided positioning and 2.) an automatic model adaptation using affine and free form deformation in order to robustly extract the kidney. In cases which show pronounced pathologies, the system also offers real time mesh editing tools for a quick refinement of the segmentation result. Evaluation results based on 30 clinical cases using CT data sets show an average dice correlation coefficient of 93% compared to the ground truth. The results are therefore in most cases comparable to manual delineation. Computation times of the automatic adaptation step are lower than 6 seconds which makes the proposed system suitable for an application in clinical practice.

  6. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Yan, E-mail: xuyan04@gmail.com; Xu, Chenchao, E-mail: chenchaoxu33@gmail.com; Kuang, Xiao, E-mail: kuangxiao.ace@gmail.com

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation.more » In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.« less

  7. Description and User Manual for a Web-Based Interface to a Transit-Loss Accounting Program for Monument and Fountain Creeks, El Paso and Pueblo Counties, Colorado

    USGS Publications Warehouse

    Kuhn, Gerhard; Krammes, Gary S.; Beal, Vivian J.

    2007-01-01

    The U.S. Geological Survey, in cooperation with Colorado Springs Utilities, the Colorado Water Conservation Board, and the El Paso County Water Authority, began a study in 2004 with the following objectives: (1) Apply a stream-aquifer model to Monument Creek, (2) use the results of the modeling to develop a transit-loss accounting program for Monument Creek, (3) revise an existing accounting program for Fountain Creek to easily incorporate ongoing and future changes in management of return flows of reusable water, and (4) integrate the two accounting programs into a single program and develop a Web-based interface to the integrated program that incorporates simple and reliable data entry that is automated to the fullest extent possible. This report describes the results of completing objectives (2), (3), and (4) of that study. The accounting program for Monument Creek was developed first by (1) using the existing accounting program for Fountain Creek as a prototype, (2) incorporating the transit-loss results from a stream-aquifer modeling analysis of Monument Creek, and (3) developing new output reports. The capabilities of the existing accounting program for Fountain Creek then were incorporated into the program for Monument Creek and the output reports were expanded to include Fountain Creek. A Web-based interface to the new transit-loss accounting program then was developed that provided automated data entry. An integrated system of 34 nodes and 33 subreaches was integrated by combining the independent node and subreach systems used in the previously completed stream-aquifer modeling studies for the Monument and Fountain Creek reaches. Important operational criteria that were implemented in the new transit-loss accounting program for Monument and Fountain Creeks included the following: (1) Retain all the reusable water-management capabilities incorporated into the existing accounting program for Fountain Creek; (2) enable daily accounting and transit-loss computations for a variable number of reusable return flows discharged into Monument Creek at selected locations; (3) enable diversion of all or a part of a reusable return flow at any selected node for purposes of storage in off-stream reservoirs or other similar types of reusable water management; (4) and provide flexibility in the accounting program to change the number of return-flow entities, the locations at which the return flows discharge into Monument or Fountain Creeks, or the locations to which the return flows are delivered. The primary component of the Web-based interface is a data-entry form that displays data stored in the accounting program input file; the data-entry form allows for entry and modification of new data, which then is rewritten to the input file. When the data-entry form is displayed, up-to-date discharge data for each station are automatically computed and entered on the data-entry form. Data for native return flows, reusable return flows, reusable return flow diversions, and native diversions also are entered automatically or manually, if needed. In computing the estimated quantities of reusable return flow and the associated transit losses, the accounting program uses two sets of computations. The first set of computations is made between any two adjacent streamflow-gaging stations (termed 'stream-segment loop'); the primary purpose of the stream-segment loop is to estimate the loss or gain in native discharge between the two adjacent streamflow-gaging stations. The second set of computations is made between any two adjacent nodes (termed 'subreach loop'); the actual transit-loss computations are made in the subreach loop, using the result from the stream-segment loop. The stream-segment loop is completed for a stream segment, and then the subreach loop is completed for each subreach within the segment. When the subreach loop is completed for all subreaches within a stream segment, the stream-segment loop is initiated for the ne

  8. Laminar-airflow equipment certification: what the pharmacist needs to know.

    PubMed

    Bryan, D; Marback, R C

    1984-07-01

    The basic information pharmacy practitioners need to determine the suitability and applicability of laminar-airflow equipment test standards and procedures is presented. The operative guideline for any laminar-flow clean bench (LFCB) certification is the cleanroom and work station requirements for controlled environments as defined by the federal government under Federal Standard 209b (FS 209b). FS 209b outlines the tests, test procedures, and acceptable performance ranges for all LFCB equipment. National Sanitation Foundation Standard Number 49 (NSF 49) is used in the certification of biological-safety cabinets (BSCs). NSF 49 covers those aspects of safety, maintenance, performance, and testing that are unique BSCs. To monitor certification properly, practitioners should be familiar with these standards and the air-velocity profile, high-efficiency particulate air filter performance, noise output, light, and electrical test procedures. A review of the requisite knowledge, experience, and reputation of certifying agents is presented, along with an outline of all the necessary procedures, equipment, and documentation to be used in the process. A thorough test report should be issued upon unit certification. As pharmacy practitioners are responsible for all other aspects of quality assurance, they should also be capable of auditing these certifications to ensure the aseptic quality of products compounded in the laminar-airflow environment.

  9. Using Self Potential and Multiphase Flow Modeling to Optimize Groundwater Pumping

    NASA Astrophysics Data System (ADS)

    Gasperikova, E.; Zhang, Y.; Hubbard, S.

    2008-12-01

    Numerical and field hydrological and geophysical studies have been conducted to investigate the impact of groundwater pumping on near-river hydrology for a segment of the Russian River at the Wohler Site, California, which is a riverbed filtration system managed by the Sonoma County Water Agency. Groundwater pumping near streams can cause a creation of unsaturated regions and hence reduce the pumping capacity and change the flow paths. A three-dimensional multiphase flow and transport model can be calibrated to the temperature, and water levels at monitoring wells based on known pumping rates, and the river stage. Streaming (self) potential (SP) is one of the electrokinetic processes that describes the coupled behavior of hydraulic and electrical flow within a porous medium, and is easily measured on the surface or in boreholes. Observing temporal and spatial variations in geophysical signatures provides a powerful approach for monitoring changes in the natural systems due to natural or forced (pumping) system perturbations. Geophysical and hydrological data were collected before, during and after a pumping experiment at the Wohler Site. Using this monitoring dataset, we illustrate how loose coupling between hydrogeological and geophysical (SP) processes and data can be used to calibrate the flow model and to optimize pumping schedules as needed to guide sustainable water resource development.

  10. Deep subsurface microbial processes

    USGS Publications Warehouse

    Lovley, D.R.; Chapelle, F.H.

    1995-01-01

    Information on the microbiology of the deep subsurface is necessary in order to understand the factors controlling the rate and extent of the microbially catalyzed redox reactions that influence the geophysical properties of these environments. Furthermore, there is an increasing threat that deep aquifers, an important drinking water resource, may be contaminated by man's activities, and there is a need to predict the extent to which microbial activity may remediate such contamination. Metabolically active microorganisms can be recovered from a diversity of deep subsurface environments. The available evidence suggests that these microorganisms are responsible for catalyzing the oxidation of organic matter coupled to a variety of electron acceptors just as microorganisms do in surface sediments, but at much slower rates. The technical difficulties in aseptically sampling deep subsurface sediments and the fact that microbial processes in laboratory incubations of deep subsurface material often do not mimic in situ processes frequently necessitate that microbial activity in the deep subsurface be inferred through nonmicrobiological analyses of ground water. These approaches include measurements of dissolved H2, which can predict the predominant microbially catalyzed redox reactions in aquifers, as well as geochemical and groundwater flow modeling, which can be used to estimate the rates of microbial processes. Microorganisms recovered from the deep subsurface have the potential to affect the fate of toxic organics and inorganic contaminants in groundwater. Microbial activity also greatly influences 1 the chemistry of many pristine groundwaters and contributes to such phenomena as porosity development in carbonate aquifers, accumulation of undesirably high concentrations of dissolved iron, and production of methane and hydrogen sulfide. Although the last decade has seen a dramatic increase in interest in deep subsurface microbiology, in comparison with the study of other habitats, the study of deep subsurface microbiology is still in its infancy.

  11. Dyke-path formation in relation to the eruptions of Eyjafjallajökull 2010 and Bardarbunga-Holuhraun 2014

    NASA Astrophysics Data System (ADS)

    Gudmundsson, Agust

    2015-04-01

    Dykes are extension fractures and form when the magmatic overpressure is high enough to rupture (break) the host rock. Their formation is entirely analogous to that of many joints and human-made hydraulic fractures, such as are used to increase permeability in reservoirs. When generating their paths, dykes use existing weaknesses (e.g., cooling joints) in the host rock. The maximum depth of large tension fractures below the surface of a rift zone, however, is mostly less than a few hundred metres. If the fractures extend to greater depths, they must change into closed normal faults which are generally not used as magma paths. There are thus no large tension fractures or wide-open faults at great depths ready to be filled with magma to form a dyke. While magma flow in dykes, as in other fluid-driven fractures, is at any point in various directions dyke segmentation may indicate the overall large-scale flow direction. Thus, dykes composed of large-spaced disconnected segments in lateral sections are primarily formed in vertical magma flow at segmentation depth whereas those composed of large-spaced disconnected segments in vertical sections are primarily formed in lateral magma flow. The far-field displacement and stress fields of segmented dykes are similar to those generated by single, continuous dykes of similar dimensions, particularly when the distances between the nearby tips of the segments become small in comparison with segment lengths. Most dykes become arrested and never supply magma to eruptions. Feeder-dykes normally reach the surface only along parts of their lengths (strike-dimensions). The volumetric flow or effusion rate of magma through a feeder-dyke or volcanic fissure depends on the aperture (opening) of the dyke or fissure in the 3rd power. All these theoretical and observational results are here applied to the dyke emplacements associated with the eruptions of Eyjafjallajökull 2010 and Bardarbunga-Holuhraun 2014. The results make it possible to (1) explain, broadly, the propagation-paths of the associated dykes, (2) the arrest and deflection (into sills) of many dyke segments, (3) the dimensions of the dykes, in particular (4) the dyke thicknesses, (5) the volumetric flow or effusion rates of the volcanic fissures, and (6) the location of the magma sources of the dykes. Galindo, I., Gudmundsson, A., 2012. Basaltic feeder dykes in rift zones: geometry, emplacement, and effusion rates. Nat. Hazards Earth Syst. Sci., 12, 3683-3700. Becerril, L., Galindo, I., Gudmundsson, A., Morales, J.M., 2013. Depth of origin of magma in eruptions. Sci. Reports (Nature Publishing), 3, 2762, doi: 10.1038/srep02762. Gudmundsson, A., Lecoeur, N., Mohajeri, N., Thordarson, T., 2014. Dike emplacement at Bardarbunga, Iceland, induces unusual stress changes, caldera deformation, and earthquakes. Bull. Volcanol., 76, 869, doi: 10.1007/s00445-014-0869-8.

  12. Characteristics of sediment transport at selected sites along the Missouri River during the high-flow conditions of 2011

    USGS Publications Warehouse

    Galloway, Joel M.; Rus, Dave L.; Alexander, Jason S.

    2013-01-01

    During 2011, many tributaries in the Missouri River Basin experienced near record peak streamflow and caused flood damage to many communities along much of the Missouri River from Montana to the confluence with the Mississippi River. The large runoff event in 2011 provided an opportunity to examine characteristics of sediment transport in the Missouri River at high-magnitude streamflow and for a long duration. The purpose of this report is to describe sediment characteristics during the 2011 high-flow conditions at six selected sites on the Missouri River, two in the middle region of the basin between Lake Sakakawea and Lake Oahe in North Dakota, and four downstream from Gavins Point Dam along the Nebraska-South Dakota and Nebraska-Iowa borders. A wider range in suspended-sediment concentration was observed in the middle segment of the Missouri River compared to sites in the lower segment. In the middle segment of the Missouri River, suspended-sediment concentrations increased and peaked as flows increased and started to plateau; however, while flows were still high and steady, suspended-sediment concentrations decreased and suspended-sediment grain sizes coarsened, indicating the decrease possibly was related to fine-sediment supply limitations. Measured bedload transport rates in the lower segment of the Missouri River (sites 3 to 6) were consistently higher than those in the middle segment (sites 1 and 2) during the high-flow conditions in 2011. The median bedload transport rate measured at site 1 was 517 tons per day and at site 2 was 1,500 tons per day. Measured bedload transport rates were highest at site 3 then decreased downstream to site 5, then increased at site 6. The median bedload transport rates were 22,100 tons per day at site 3; 5,640 tons per day at site 4; 3,930 tons per day at site 5; and 8,450 tons per day at site 6. At the two sites in the middle segment of the Missouri River, the greatest bedload was measured during the recession of the streamflow hydrograph. A similar pattern was observed at sites 3–5 in the lower segment of the Missouri River, where the greatest bedload was measured later in the event on the recession of the streamflow hydrograph, although the change in bedload was not as dramatic as observed at the sites in the middle segment of the Missouri River. With the exception of site 3, the total-sediment load on the Missouri River was highest at the beginning of the high-flow event and decreased as streamflow decreased. In the middle segment of the Missouri River, measured total-sediment load ranged from 2,320 to 182,000 tons per day at site 1 and from 3,190 to 279,000 tons per day at site 2. In the lower segment of the Missouri River, measured total-sediment load ranged from 50,600 to 223,000 tons per day at site 4; from 23,500 to 403,000 tons per day at site 5; and from 52,700 to 273,000 tons per day at site 6. The total-sediment load was dominated by suspended sediment at all of the sites measured on the Missouri River in 2011. In general, the percentage of total-sediment load that was bedload increased as the streamflow decreased, although this pattern was more prevalent at sites in the middle segment than those in the lower segment. The suspended-sediment load comprised an average of 93 percent of the total load, with the exception of site 3, where the suspended-sediment load comprised only 72 percent of the total-sediment load.

  13. Effect of stem water content on sap flow from dormant maple and butternut stems: induction of sap flow in butternut.

    PubMed

    Johnson, R W; Tyree, M T

    1992-10-01

    Sap flow from excised maple stems collected over the winter (1986/87) was correlated with stem water content. Stem water content was high in the fall (>0.80) and decreased rapidly during 2 weeks of continuous freezing temperatures in late winter (<0.60). Exudation of sap from stem segments subjected to freeze/thaw cycles was small (<10 mL/kg) in the fall, but substantial exudation (45-50 mL/kg) occurred following the decline in water content. These observations are consistent with Milburn's and O'Malley's models (J.A. Milburn, P.E.R. O'Malley [1984] Can J Bot 62: 2101-2106; P.E.R. O'Malley, J.A. Milburn [1983] Can J Bot 61:3100-3106) of sap absorption into gas-filled fibers during freezing. Exudation volume was increased 200 to 300% in maple stems originally at high water content (>0.80) after perfusion with sucrose and dehydration at -12 degrees C. Sap flow was also induced in butternut stem segments after the same treatment. Thus, sap flow may not be unique to maples. Sap flow could not be increased in stem segments dehydrated at 4 degrees C. Migration of water molecules from small ice crystals in fibers to larger crystals in vessels while stems were frozen may account for increase exudation after dehydration at -12 degrees C. This would result in preferential dehydration of fibers and a distribution of gas and sap favorable for stem-based sap flow.

  14. Vision-based in-line fabric defect detection using yarn-specific shape features

    NASA Astrophysics Data System (ADS)

    Schneider, Dorian; Aach, Til

    2012-01-01

    We develop a methodology for automatic in-line flaw detection in industrial woven fabrics. Where state of the art detection algorithms apply texture analysis methods to operate on low-resolved ({200 ppi) image data, we describe here a process flow to segment single yarns in high-resolved ({1000 ppi) textile images. Four yarn shape features are extracted, allowing a precise detection and measurement of defects. The degree of precision reached allows a classification of detected defects according to their nature, providing an innovation in the field of automatic fabric flaw detection. The design has been carried out to meet real time requirements and face adverse conditions caused by loom vibrations and dirt. The entire process flow is discussed followed by an evaluation using a database with real-life industrial fabric images. This work pertains to the construction of an on-loom defect detection system to be used in manufacturing practice.

  15. Along-axis hydrothermal flow at the axis of slow spreading Mid-Ocean Ridges: Insights from numerical models of the Lucky Strike vent field (MAR)

    NASA Astrophysics Data System (ADS)

    Fontaine, Fabrice J.; Cannat, Mathilde; Escartin, Javier; Crawford, Wayne C.

    2014-07-01

    processes and efficiency of hydrothermal heat extraction along the axis of mid-ocean ridges are controlled by lithospheric thermal and permeability structures. Hydrothermal circulation models based on the structure of fast and intermediate spreading ridges predict that hydrothermal cell organization and vent site distribution are primarily controlled by the thermodynamics of high-temperature mid-ocean ridge hydrothermal fluids. Using recent constraints on shallow structure at the slow spreading Lucky Strike segment along the Mid-Atlantic Ridge, we present a physical model of hydrothermal cooling that incorporates the specificities of a magma-rich slow spreading environment. Using three-dimensional numerical models, we show that, in contrast to the aforementioned models, the subsurface flow at Lucky Strike is primarily controlled by across-axis permeability variations. Models with across-axis permeability gradients produce along-axis oriented hydrothermal cells and an alternating pattern of heat extraction highs and lows that match the distribution of microseismic clusters recorded at the Lucky Strike axial volcano. The flow is also influenced by temperature gradients at the base of the permeable hydrothermal domain. Although our models are based on the structure and seismicity of the Lucky Strike segment, across-axis permeability gradients are also likely to occur at faster spreading ridges and these results may also have important implications for the cooling of young crust at fast and intermediate spreading centers.

  16. Continuous Polyol Synthesis of Metal and Metal Oxide Nanoparticles Using a Segmented Flow Tubular Reactor (SFTR).

    PubMed

    Testino, Andrea; Pilger, Frank; Lucchini, Mattia Alberto; Quinsaat, Jose Enrico Q; Stähli, Christoph; Bowen, Paul

    2015-06-08

    Over the last years a new type of tubular plug flow reactor, the segmented flow tubular reactor (SFTR), has proven its versatility and robustness through the water-based synthesis of precipitates as varied as CaCO3, BaTiO3, Mn(1-x)NixC2O4·2H2O, YBa oxalates, copper oxalate, ZnS, ZnO, iron oxides, and TiO2 produced with a high powder quality (phase composition, particle size, and shape) and high reproducibility. The SFTR has been developed to overcome the classical problems of powder production scale-up from batch processes, which are mainly linked with mass and heat transfer. Recently, the SFTR concept has been further developed and applied for the synthesis of metals, metal oxides, and salts in form of nano- or micro-particles in organic solvents. This has been done by increasing the working temperature and modifying the particle carrying solvent. In this paper we summarize the experimental results for four materials prepared according to the polyol synthesis route combined with the SFTR. CeO2, Ni, Ag, and Ca3(PO4)2 nanoparticles (NPs) can be obtained with a production rate of about 1-10 g per h. The production was carried out for several hours with constant product quality. These findings further corroborate the reliability and versatility of the SFTR for high throughput powder production.

  17. Optimal Filter Estimation for Lucas-Kanade Optical Flow

    PubMed Central

    Sharmin, Nusrat; Brad, Remus

    2012-01-01

    Optical flow algorithms offer a way to estimate motion from a sequence of images. The computation of optical flow plays a key-role in several computer vision applications, including motion detection and segmentation, frame interpolation, three-dimensional scene reconstruction, robot navigation and video compression. In the case of gradient based optical flow implementation, the pre-filtering step plays a vital role, not only for accurate computation of optical flow, but also for the improvement of performance. Generally, in optical flow computation, filtering is used at the initial level on original input images and afterwards, the images are resized. In this paper, we propose an image filtering approach as a pre-processing step for the Lucas-Kanade pyramidal optical flow algorithm. Based on a study of different types of filtering methods and applied on the Iterative Refined Lucas-Kanade, we have concluded on the best filtering practice. As the Gaussian smoothing filter was selected, an empirical approach for the Gaussian variance estimation was introduced. Tested on the Middlebury image sequences, a correlation between the image intensity value and the standard deviation value of the Gaussian function was established. Finally, we have found that our selection method offers a better performance for the Lucas-Kanade optical flow algorithm.

  18. High flux reactor

    DOEpatents

    Lake, James A.; Heath, Russell L.; Liebenthal, John L.; DeBoisblanc, Deslonde R.; Leyse, Carl F.; Parsons, Kent; Ryskamp, John M.; Wadkins, Robert P.; Harker, Yale D.; Fillmore, Gary N.; Oh, Chang H.

    1988-01-01

    A high flux reactor is comprised of a core which is divided into two symetric segments housed in a pressure vessel. The core segments include at least one radial fuel plate. The spacing between the plates functions as a coolant flow channel. The core segments are spaced axially apart such that a coolant mixing plenum is formed between them. A channel is provided such that a portion of the coolant bypasses the first core section and goes directly into the mixing plenum. The outlet coolant from the first core segment is mixed with the bypass coolant resulting in a lower inlet temperature to the lower core segment.

  19. Validation of FMTV Modular VHP/mVHP System and Fumigation Decontamination Process in a C-141B Starlifter Aircraft

    DTIC Science & Technology

    2007-08-01

    each location was aseptically transferred to 5 mL Tryptic Soy Broth (TSB) and incubated at 55 ’C. Coupons were observed the following day. If...Samples were then serially diluted in buffered peptone water and pour plated (1 mL per plate) using Tryptic Soy Agar (TSA). Plates were gently swirled in...1260 area. aft surface inside of hydraulic oil box 19 39 Starboard - 750. 59 On V2 79 On platform, 99 Aft, overhead in on oxygen box overhead, forward

  20. A Quantitative Analysis of the Fretted Terrain Valleys, Arabia Terra, Mars

    NASA Astrophysics Data System (ADS)

    Mason, Kelsey Anne

    Fretted terrain describes regions on Mars with low-lying, flat valleys separated by steep cliffs that often form polygonal-shaped mesas. The fretted terrain valleys have a morphology distinct from other valleys found on Mars, and their unknown origin may hold insights into critical questions about Mars' tectonic, magmatic, and hydrologic history. Current hypothesis for the formation of the fretted terrain include fracturing as well as hydrological flow processes such as fluvial or glacial erosion. The region for this study is located in eastern Arabia Terra and is the type-location for fretted terrain. By qualitatively and quantitatively documenting the planform, or map-view, valley geometries and orientations throughout the fretted terrain, this study better constrains the origin of the valleys. Valleys were mapped using automated routines in ArcGIS including the D8 flow direction algorithm. Valleys were then grouped geographically into basins and also by Strahler order. The valleys were then segmented every 50 km and the azimuth of each segment was calculated. The resulting valley azimuths were analyzed using rose diagrams to quantitatively describe the planform geometries of the valleys. Qualitatively, the majority of basins were found to have rectangular valley geometries. The downslope direction was calculated for each basin, and it was compared to the corresponding valley azimuths. The basins with rectangular valley geometries had valleys with an azimuth mode nearly parallel to the downslope direction and another azimuth mode perpendicular to the downslope direction. The valley azimuth mode parallel to the downslope direction is attributed to hydrological flow processes while the mode perpendicular to the downslope direction is attributed to fracturing related to the formation or existence of the Mars global dichotomy boundary.

  1. Regulation of Extracellular Matrix Remodeling Proteins by Osteoblasts in Titanium Nanoparticle-Induced Aseptic Loosening Model.

    PubMed

    Xie, Jing; Hou, Yanhua; Fu, Na; Cai, Xiaoxiao; Li, Guo; Peng, Qiang; Lin, Yunfeng

    2015-10-01

    Titanium (Ti)-wear particles, formed at the bone-implant interface, are responsible for aseptic loosening, which is a main cause of total joint replacement failure. There have been many studies on Ti particle-induced function changes in mono-cultured osteoblasts and synovial cells. However, little is known on extracellular matrix remodeling displayed by osteoblasts when in coexistence with Synovial cells. To further mimic the bone-implant interface environment, we firstly established a nanoscaled-Ti particle-induced aseptic loosening system by co-culturing osteoblasts and Synovial cells. We then explored the impact of the Synovial cells on Ti particle-engulfed osteoblasts in the mimicked flamed niche. The matrix metalloproteinases and lysyl oxidases expression levels, two protein families which are critical in osseointegration, were examined under induction by tumor necrosis factor-alpha. It was found that the co-culture between the osteoblasts and Synovial cells markedly increased the migration and proliferation of the osteoblasts, even in the Ti-particle engulfed osteoblasts. Importantly, the Ti-particle engulfed osteoblasts, induced by TNF-alpha after the co-culture, enhanced the release of the matrix metalloproteinases and reduced the expressions of lysyl oxidases. The regulation of extracellular matrix remodeling at the protein level was further assessed by investigations on gene expression of the matrix metalloproteinases and lysyl oxidases, which also suggested that the regulation started at the genetic level. Our research work has therefore revealed the critical role of multi cell-type interactions in the extracellular matrix remodeling within the peri-prosthetic tissues, which provides new insights on aseptic loosening and brings new clues about incomplete osseointegration between the implantation materials and their surrounding bones.

  2. Scintigraphy of infected total hip arthroplasty (THA): A canine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merkel, K.D.; Brown, M.L.; Fitzgerald, R.H.

    1984-01-01

    Differentiating low-grade sepsis from aseptic loosening of an orthopedic prosthesis is difficult. This study was designed to compare the ability of Tc-99m-HMDP, Ga-67, and In-111 leukocytes (WC) to differentiate low-grade sepsis from aseptic THA component loosening in a canine model. A canine THA was implanted in 14 dogs. Six dogs were given infected femoral components by injecting 10/sup 5/ colony-forming units of Staphylococcus aureus into the femoral canal 6y0 to 90 seconds prior to cementing. Four dogs had an aseptic loose femoral component, and four dogs had an aseptic tight femoral component (control). At six months all dogs were evaluatedmore » with X-ray, lab scintigraphy, and tissue quantitation of each tracer. Diagnosis was confirmed by histology and quantitative microbiology. White blood cell counts and differentials were normal in all dogs, and in only one out of six infected dogs was the sedimentation rate abnormal. X-rays were interpreted as possible infection in five dogs and probable infection in only one dog. In-111 WBC scans were more accurate than sequential Tc-Ga scans (sensitivity 94% vs 61%, specificity 86% vs 71% accuracy 90% vs 67%). Quantitative counting of gamma camera data and tissue samples demonstrated significantly (P < .01) higher accumulation of In-111 WBC about the infected than the loose or control component. No significant difference was demonstrated between the loose and septic components with TC-HMDP or Ga. These results correlate well and confirm our clinical data that In-111 WBC scanning is accurate and useful in the workup of the painful orthopedic prosthesis.« less

  3. Comparative study suggests that human bone morphogenetic proteins have no influence on the outcome of operative treatment of aseptic clavicle non-unions.

    PubMed

    von Rüden, Christian; Morgenstern, Mario; Friederichs, Jan; Augat, Peter; Hackl, Simon; Woltmann, Alexander; Bühren, Volker; Hierholzer, Christian

    2016-11-01

    The purpose of this study was to evaluate the clinical and radiological outcome following compression plate fixation in combination with autologous bone grafting, with and without additional application of recombinant human bone morphogenetic protein (rhBMP) for treatment of aseptic clavicle non-union. Between April 2004 and April 2015, 82 patients were treated for clavicle fracture and had developed aseptic clavicle non-union. Seventy-three out of 82 patients were available for follow-up at least one year after revision surgery; among them, 27 women and 46 men, with a median age of 49 (range, 19-86) years. Forty-five patients received compression plate osteosynthesis with autologous bone grafting, and 28 patients obtained compression plate fixation with autologous bone grafting and additional application of rhBMP-2 (3/28 patients) or rhBMP-7 (25/28 patients). Seventy out of 73 non-unions (96 %) healed within 12 months after revision surgery. Functional outcome according to the DASH Outcome Measure (with rhBMP, 33.16 ± 1.17 points; without rhBMP, 30.58 ± 2.12 points [mean ± SEM]; p = 0.81), non-union healing (p = 0.86), time interval between revision surgery and bone healing (p = 0.37), as well as post-operative complications, did not demonstrate relevant differences between the treatment groups and were not age-dependent. Functional and radiological results demonstrate that successful healing of aseptic clavicle non-union is dependent on radical resection of non-union tissue, restoration of length of the shoulder girdle and application of stable locking-plate osteosynthesis in combination with autologous bone grafting, but not dependent on application of additional rhBMP.

  4. Recent outbreak of aseptic meningitis in Italy due to Echovirus 30 and phylogenetic relationship with other European circulating strains.

    PubMed

    Milia, Maria Grazia; Cerutti, Francesco; Gregori, Gabriella; Burdino, Elisa; Allice, Tiziano; Ruggiero, Tina; Proia, Maria; De Rosa, Giulia; Enrico, Eugenia; Lipani, Filippo; Di Perri, Giovanni; Ghisetti, Valeria

    2013-11-01

    Enteroviruses (EVs) are common human viral pathogens, causing a variety of diseases, including aseptic meningitis. Recently, EV aseptic meningitis outbreaks have been reported across Europe, but, in Italy, knowledge of recent EV molecular epidemiology is very limited. We report an outbreak of EV aseptic meningitis in 10 adults in North-Western Italy, from October to November 2012. Patients were parents or close relatives of children <5 years old attending the same class of a nursery school, suffering from a mild febrile upper respiratory disease. Phylogenetic relationship with other European circulating strains was analyzed updating E30 circulation in Italy in recent years. EVs were detected from cerebrospinal fluid (CSF) specimens with a real-time reverse transcription polymerase chain reaction and virus isolation was achieved from rectal and pharyngeal swabs. For cluster definition and phylogenetic studies, viral VP1 region was directly amplified and sequenced from CSF. EVs were identified in CSF from all patients and from rectal and pharyngeal swabs in 7 of them. Direct sequencing of CSF revealed the presence of the same Echovirus 30 (E30) in all patients and phylogenetic analysis identified it as a diverging clade within E30 genotype VII, the most recent strain circulating in UK, Finland and Denmark since 2006. Molecular techniques allowed the rapid identification and typing of E30 from CSF. Phylogenetic analysis revealed that the cluster might be due to a new E30 variant within the genotype VII currently circulating in Europe, thus updating the epidemiology of EV circulation in Italy. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Laboratory investigation and phylogenetic analysis of enteroviruses involved in an aseptic meningitis outbreak in Greece during the summer of 2007.

    PubMed

    Logotheti, Maria; Pogka, Vasiliki; Horefti, Elina; Papadakos, Konstantinos; Giannaki, Maria; Pangalis, Anastasia; Sgouras, Dionyssios; Mentis, Andreas

    2009-11-01

    Aseptic meningitis is the most commonly observed CNS infection and is mainly attributed to Non-Polio Enteroviruses (EV). Identification and genetic analysis of the EV involved in the recent aseptic meningitis outbreak which occurred in Greece, during the summer of 2007. In total, 213 CSF and faecal samples were examined for EV presence by culture, while enteroviral RNA detection was performed by nucleic acid sequence-based amplification assay (NASBA). EV strains were typed by seroneutralization, as well as nested RT-PCR followed by VP1-2A gene partial sequencing. Phylogenetic analysis was carried out for the identification of the genetic relatedness among the isolated EV strains. EV detection rate in CSF and faecal samples was 43.9% and 70.8%, respectively. EV serotyping and VP1 region analysis revealed the predominance of echovirus 4 (ECV4) serotype and the circulation of ECV6, 9, 14, 25, Coxsackie A6, A15, A24 and Coxsackie B1 serotypes. All ECV4 isolates presented a 98.7% similarity in nucleotide sequence, with a Spanish ECV4 strain, isolated during a meningitis outbreak in 2006. It is the first time that ECV4 is associated with an aseptic meningitis outbreak in Greece, during which 9 different EV serotypes were co-circulating. All Greek ECV4 isolates were closely related to the Spanish ECV4 strain. Genetic analysis of the VP1 gene can significantly contribute to the revelation of the endemic EV strains circulation pattern and their phylogenetic relationship with enteroviruses involved in epidemics of distant geographical areas at different time periods.

  6. Human prosthetic joint infections are associated with myeloid-derived suppressor cells (MDSCs): Implications for infection persistence.

    PubMed

    Heim, Cortney E; Vidlak, Debbie; Odvody, Jessica; Hartman, Curtis W; Garvin, Kevin L; Kielian, Tammy

    2017-11-15

    Prosthetic joint infection (PJI) is a devastating complication of joint arthroplasty surgery typified by biofilm formation. Currently, mechanisms whereby biofilms persist and evade immune-mediated clearance in immune competent patients remain largely ill-defined. Therefore, the current study characterized leukocyte infiltrates and inflammatory mediator expression in tissues from patients with PJI compared to aseptic loosening. CD33 + HLA-DR - CD66b + CD14 -/low granulocytic myeloid-derived suppressor cells (G-MDSCs) were the predominant leukocyte population at sites of human PJI compared to aseptic tissues. MDSCs inhibit T cell proliferation, which coincided with reduced T cells in PJIs compared to aseptic tissues. IL-10, IL-6, and CXCL1 were significantly elevated in PJI tissues and have been implicated in MDSC inhibitory activity, expansion, and recruitment, respectively, which may account for their preferential increase in PJIs. This bias towards G-MDSC accumulation during human PJI could account for the chronicity of these infections by preventing the pro-inflammatory, antimicrobial actions of immune effector cells. Animal models of PJI have revealed a critical role for MDSCs and IL-10 in promoting infection persistence; however, whether this population is prevalent during human PJI and across distinct bacterial pathogens remains unknown. This study has identified that granulocytic-MDSC infiltrates are unique to human PJIs caused by distinct bacteria, which are not associated with aseptic loosening of prosthetic joints. Better defining the immune status of human PJIs could lead to novel immune-mediated approaches to facilitate PJI clearance in combination with conventional antibiotics. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. Hierarchically nested river landform sequences

    NASA Astrophysics Data System (ADS)

    Pasternack, G. B.; Weber, M. D.; Brown, R. A.; Baig, D.

    2017-12-01

    River corridors exhibit landforms nested within landforms repeatedly down spatial scales. In this study we developed, tested, and implemented a new way to create river classifications by mapping domains of fluvial processes with respect to the hierarchical organization of topographic complexity that drives fluvial dynamism. We tested this approach on flow convergence routing, a morphodynamic mechanism with different states depending on the structure of nondimensional topographic variability. Five nondimensional landform types with unique functionality (nozzle, wide bar, normal channel, constricted pool, and oversized) represent this process at any flow. When this typology is nested at base flow, bankfull, and floodprone scales it creates a system with up to 125 functional types. This shows how a single mechanism produces complex dynamism via nesting. Given the classification, we answered nine specific scientific questions to investigate the abundance, sequencing, and hierarchical nesting of these new landform types using a 35-km gravel/cobble river segment of the Yuba River in California. The nested structure of flow convergence routing landforms found in this study revealed that bankfull landforms are nested within specific floodprone valley landform types, and these types control bankfull morphodynamics during moderate to large floods. As a result, this study calls into question the prevailing theory that the bankfull channel of a gravel/cobble river is controlled by in-channel, bankfull, and/or small flood flows. Such flows are too small to initiate widespread sediment transport in a gravel/cobble river with topographic complexity.

  8. Evaluation of free flow speeds on interrupted flow facilities.

    DOT National Transportation Integrated Search

    2013-05-01

    The efficacy of the Florida Department of Transportation (FDOT) simple model of predicting segment free flow speed by adding 5 miles per hour (mph) to the posted speed limit was compared to the performance of the new 2010 Highway Capacity Manual (HCM...

  9. Three-dimensional visualization of morphology and ventilation procedure (air flow and diffusion) of a subdivision of the acinus using synchrotron radiation microtomography of the human lung specimens

    NASA Astrophysics Data System (ADS)

    Shimizu, Kenji; Ikura, Hirohiko; Ikezoe, Junpei; Nagareda, Tomofumi; Yagi, Naoto; Umetani, Keiji; Imai, Yutaka

    2004-04-01

    We have previously reported a synchrotron radiation (SR) microtomography system constructed at the bending magnet beamline at the SPring-8. This system has been applied to the lungs obtained at autopsy and inflated and fixed by Heitzman"s method. Normal lung and lung specimens with two different types of pathologic processes (fibrosis and emphysema) were included. Serial SR microtomographic images were stacked to yield the isotropic volumetric data with high-resolution (12 μm3 in voxel size). Within the air spaces of a subdivision of the acinus, each voxel is segmented three-dimensionally using a region growing algorithm ("rolling ball algorithm"). For each voxel within the segmented air spaces, two types of voxel coding have been performed: single-seeded (SS) coding and boundary-seeded (BS) coding, in which the minimum distance from an initial point as the only seed point and all object boundary voxels as a seed set were calculated and assigned as the code values to each voxel, respectively. With these two codes, combinations of surface rendering and volume rendering techniques were applied to visualize three-dimensional morphology of a subdivision of the acinus. Furthermore, sequentially filling process of air into a subdivision of the acinus was simulated under several conditions to visualize the ventilation procedure (air flow and diffusion). A subdivision of the acinus was reconstructed three-dimensionally, demonstrating the normal architecture of the human lung. Significant differences in appearance of ventilation procedure were observed between normal and two pathologic processes due to the alteration of the lung architecture. Three-dimensional reconstruction of the microstructure of a subdivision of the acinus and visualization of the ventilation procedure (air flow and diffusion) with SR microtomography would offer a new approach to study the morphology, physiology, and pathophysiology of the human respiratory system.

  10. Scaling Relations for the Thermal Structure of Segmented Oceanic Transform Faults

    NASA Astrophysics Data System (ADS)

    Wolfson-Schwehr, M.; Boettcher, M. S.; Behn, M. D.

    2015-12-01

    Mid-ocean ridge-transform faults (RTFs) are a natural laboratory for studying strike-slip earthquake behavior due to their relatively simple geometry, well-constrained slip rates, and quasi-periodic seismic cycles. However, deficiencies in our understanding of the limited size of the largest RTF earthquakes are due, in part, to not considering the effect of short intra-transform spreading centers (ITSCs) on fault thermal structure. We use COMSOL Multiphysics to run a series of 3D finite element simulations of segmented RTFs with visco-plastic rheology. The models test a range of RTF segment lengths (L = 10-150 km), ITSC offset lengths (O = 1-30 km), and spreading rates (V = 2-14 cm/yr). The lithosphere and upper mantle are approximated as steady-state, incompressible flow. Coulomb failure incorporates brittle processes in the lithosphere, and a temperature-dependent flow law for dislocation creep of olivine activates ductile deformation in the mantle. ITSC offsets as small as 2 km affect the thermal structure underlying many segmented RTFs, reducing the area above the 600˚C isotherm, A600, and thus the size of the largest expected earthquakes, Mc. We develop a scaling relation for the critical ITSC offset length, OC, which significantly reduces the thermal affect of adjacent fault segments of length L1 and L2. OC is defined as the ITSC offset that results in an area loss ratio of R = (Aunbroken - Acombined)/Aunbroken - Adecoupled) = 63%, where Aunbroken = C600(L1+L2)1.5V-0.6 is A600 for an RTF of length L1 + L2; Adecoupled = C600(L11.5+L21.5)V-0.6 is the combined A600 of RTFs of lengths L1 and L2, respectively; and Acombined = Aunbroken exp(-O/ OC) + Adecoupled (1-exp(-O/ OC)). C600 is a constant. We use OC and kinematic fault parameters (L1, L2, O, and V) to develop a scaling relation for the approximate seismogenic area, Aseg, for each segment of a RTF system composed of two fault segments. Finally, we estimate the size of Mc on a fault segment based on Aseg. We show that small (<1 km) offsets in the fault trace observed between M­W6 rupture patches on Gofar and Discovery transform faults, located at ~4S on the East Pacific Rise, are not sufficient to thermally decouple adjacent fault patches. Thus additional factors, possibly including changes in fault zone material properties, must limit the size of Mc on these faults.

  11. Morphodynamics of submarine channel inception revealed by new experimental approach

    PubMed Central

    de Leeuw, Jan; Eggenhuisen, Joris T.; Cartigny, Matthieu J. B.

    2016-01-01

    Submarine channels are ubiquitous on the seafloor and their inception and evolution is a result of dynamic interaction between turbidity currents and the evolving seafloor. However, the morphodynamic links between channel inception and flow dynamics have not yet been monitored in experiments and only in one instance on the modern seafloor. Previous experimental flows did not show channel inception, because flow conditions were not appropriately scaled to sustain suspended sediment transport. Here we introduce and apply new scaling constraints for similarity between natural and experimental turbidity currents. The scaled currents initiate a leveed channel from an initially featureless slope. Channelization commences with deposition of levees in some slope segments and erosion of a conduit in other segments. Channel relief and flow confinement increase progressively during subsequent flows. This morphodynamic evolution determines the architecture of submarine channel deposits in the stratigraphic record and efficiency of sediment bypass to the basin floor. PMID:26996440

  12. Therapeutic effects of OP-1 on metal wear particle induced osteoblasts injury in vitro

    PubMed Central

    Sun, Guojing; Chen, Jianmin; Yang, Shufeng; Parker, Thomas MN; Goodman, Gary MP; Hasama, Jack M; Zhao, Jianning

    2015-01-01

    Aseptic lossening is a main reason for the revision of total joint arthroplasty. Metal-wear particles induced deregulation of bone resorption or formation has been considered as the major process of aseptic lossening. Osteogenic protein-1 (OP-1) can be used to improve bone formation. However, such effect is not clearly understood after the metal-wear particles injury. Here, we investigated the molecular mechanisms by which OP-1 regulates the activity of bone formation and anti-inflammatory after injury. Results showed that OP-1 increased cell viability and bone formation ability of impaired osteoblast cells at 72 hours after being injured by cobalt particles. Pathway analyses revealed that both mRNA and protein levels of Smad1 and Smad5 were significantly increased upon the treatment of OP-1 in the cell injury model. Similarly, runt-related transcription factor 2 (Runx2) was also significantly upregulated in the OP-1 treated cells. Moreover, treatment with OP-1 inhibited the secretion of interleukin 6 (IL-6), tumor necrosis factor alpha (TNF-α), and IL-18 in cobalt impaired cells. Collectively, these results suggest that OP-1 could inhibit cobalt particles induced cell injury by activating Smad1, Smad5, and Runx2, and such procedure is accompanied by anti-inflammatory reaction. PMID:26885192

  13. Proposal for adaptive management to conserve biotic integrity in a regulated segment of the Tallapoosa River, Alabama, U.S.A

    USGS Publications Warehouse

    Irwin, Elise R.; Freeman, Mary C.

    2002-01-01

    Conserving river biota will require innovative approaches that foster and utilize scientific understanding of ecosystem responses to alternative river-management scenarios. We describe ecological and societal issues involved in flow management of a section of the Tallapoosa River (Alabama, U.S.A.) in which a species-rich native fauna is adversely affected by flow alteration by an upstream hydropower dam. We hypothesize that depleted Iow flows, flow instability and thermal alteration resulting from pulsed flow releases at the hydropower dam are most responsible for changes in the Tallapoosa River biota. However, existing data are insufficient to prescribe with certainty minimum flow levels or the frequency and duration of stable flow periods that would be necessary or sufficient to protect riverine biotic integrity. Rather than negotiate a specific change in the flow regime, we propose that stakeholders--including management agencies, the power utility, and river advocates--engage in a process of adaptive-flow management. This process would require that stakeholders (1) develop and agree to management objectives; (2) model hypothesized relations between dam operations and management objectives; (3) implement a change in dam operations; and (4) evaluate biological responses and other stakeholder benefits through an externally reviewed monitoring program. Models would be updated with monitoring data and stakeholders would agree to further modify flow regimes as necessary to achieve management objectives. A primary obstacle to adaptive management will be a perceived uncertainty of future costs for the power utility and other stakeholders. However, an adaptive, iterative approach offers the best opportunity for improving flow regimes for native biota while gaining information critical to guiding management decisions in other flow-regulated rivers.

  14. KSC-04pd1476

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - Unpacking of the Pump Flow Control Subsystem (PFCS) begins in the Space Station Processing Facility. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  15. KSC-04pd1477

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - Technicians attach a crane to the Pump Flow Control Subsystem (PFCS) in the Space Station Processing Facility. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  16. JWST Wavefront Control Toolbox

    NASA Technical Reports Server (NTRS)

    Shin, Shahram Ron; Aronstein, David L.

    2011-01-01

    A Matlab-based toolbox has been developed for the wavefront control and optimization of segmented optical surfaces to correct for possible misalignments of James Webb Space Telescope (JWST) using influence functions. The toolbox employs both iterative and non-iterative methods to converge to an optimal solution by minimizing the cost function. The toolbox could be used in either of constrained and unconstrained optimizations. The control process involves 1 to 7 degrees-of-freedom perturbations per segment of primary mirror in addition to the 5 degrees of freedom of secondary mirror. The toolbox consists of a series of Matlab/Simulink functions and modules, developed based on a "wrapper" approach, that handles the interface and data flow between existing commercial optical modeling software packages such as Zemax and Code V. The limitations of the algorithm are dictated by the constraints of the moving parts in the mirrors.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakamoto, T.; Monafo, W.W.

    We used the tissue distribution of ({sup 14}C)butanol to quantitate regional blood flow in the spinal cord (RSCBF) of pentobarbital-anesthetized, normothermic rats in which segmental local cooling pentobarbital-anesthetized, normothermic rats in which segmental local cooling of the spinal cord (to 25-28{degrees}C) at vertebral levels C4-C6 (n = 6) or T13-L1 (n = 6) was induced. Thirty minutes later, blood flow measurements were made at seven levels of the spinal cord and in the sciatic nerve trunks and biceps femoris muscles. Sham-cooled rats served as controls (n = 12). In control rats, RSCBF varied between 41.5 +/- 2.4 and 65.1 +/-more » 3.2 ml.min-1.100 g-1. Local cooling of the C4-C6 cord segment reduced RSCBF by 32%, from 65.1 +/- 3.2 to 44.4 +/- 3.5 ml.min-1.100 g-1 (P less than 0.01). Tissue vascular resistance (R) in the cooled C4-C6 segment was elevated versus control. There were no other changes in RSCBF at the other cord levels or in the cauda equina. Similarly, local cooling of the T13-L1 segment resulted in a 40% fall in RSCBF in that segment, from 57.1 +/- 2.4 to 34.1 +/- 4.3 ml.min-1.100 g-1 (P less than 0.001). R in the cooled T13-L1 segment was elevated versus control. RSCBF was reduced by 30% in the adjacent proximal T12 segment (P less than 0.001) and by 21% in the adjacent distal L2-L3 segment (P less than 0.05). R was increased in both of these adjacent segments. RSCBF was not altered elsewhere in the cord.« less

  18. A robustness test of the braided device foreshortening algorithm

    NASA Astrophysics Data System (ADS)

    Moyano, Raquel Kale; Fernandez, Hector; Macho, Juan M.; Blasco, Jordi; San Roman, Luis; Narata, Ana Paula; Larrabide, Ignacio

    2017-11-01

    Different computational methods have been recently proposed to simulate the virtual deployment of a braided stent inside a patient vasculature. Those methods are primarily based on the segmentation of the region of interest to obtain the local vessel morphology descriptors. The goal of this work is to evaluate the influence of the segmentation quality on the method named "Braided Device Foreshortening" (BDF). METHODS: We used the 3DRA images of 10 aneurysmatic patients (cases). The cases were segmented by applying a marching cubes algorithm with a broad range of thresholds in order to generate 10 surface models each. We selected a braided device to apply the BDF algorithm to each surface model. The range of the computed flow diverter lengths for each case was obtained to calculate the variability of the method against the threshold segmentation values. RESULTS: An evaluation study over 10 clinical cases indicates that the final length of the deployed flow diverter in each vessel model is stable, shielding maximum difference of 11.19% in vessel diameter and maximum of 9.14% in the simulated stent length for the threshold values. The average coefficient of variation was found to be 4.08 %. CONCLUSION: A study evaluating how the threshold segmentation affects the simulated length of the deployed FD, was presented. The segmentation algorithm used to segment intracranial aneurysm 3D angiography images presents small variation in the resulting stent simulation.

  19. The Packing and Jamming of Real Polymer Chains

    NASA Astrophysics Data System (ADS)

    Xue, Gi; Teng, Chao

    2010-03-01

    Jamming make a hope to unifying theme for granular materials, glasses and threshold behavior in materials. Here we experimentally prepared a real polymer (polystyrene, PS) with various packing density which was described by inter-segment distances (r) detected by NMR. We cold-pressed PS powder at 20 ^oC (with shearing) and then released the pressure. We found that a transparent pellet with high modulus was formed. PS is usually manufactured by a hot-melting process at 180 ^oC. The rigidity and transparency of our cold-pressed pellet and its accuracy of the form are testimony that the PS powder once flowed under cold compression to take the shape of its container. This shear-induced melting is exactly what is expected within the jamming picture. By measuring r and the applied pressure σ under which the polymer chain starts to flow, we drew a schematic jamming phase diagram. The σ-r curve for a real polymer is convex at r < 0.5 nm, while it becomes concave as r is larger than 1 nm. It is the van der Waals attraction that acts as a confining pressure on segments, and makes the σ-r curve convex on the very short scales.

  20. Space Adaptation of Active Mirror Segment Concepts

    NASA Technical Reports Server (NTRS)

    Ames, Gregory H.

    1999-01-01

    This report summarizes the results of a three year effort by Blue Line Engineering Co. to advance the state of segmented mirror systems in several separate but related areas. The initial set of tasks were designed to address the issues of system level architecture, digital processing system, cluster level support structures, and advanced mirror fabrication concepts. Later in the project new tasks were added to provide support to the existing segmented mirror testbed at Marshall Space Flight Center (MSFC) in the form of upgrades to the 36 subaperture wavefront sensor. Still later, tasks were added to build and install a new system processor based on the results of the new system architecture. The project was successful in achieving a number of important results. These include the following most notable accomplishments: 1) The creation of a new modular digital processing system that is extremely capable and may be applied to a wide range of segmented mirror systems as well as many classes of Multiple Input Multiple Output (MIMO) control systems such as active structures or industrial automation. 2) A new graphical user interface was created for operation of segmented mirror systems. 3) The development of a high bit rate serial data loop that permits bi-directional flow of data to and from as many as 39 segments daisy-chained to form a single cluster of segments. 4) Upgrade of the 36 subaperture Hartmann type Wave Front Sensor (WFS) of the Phased Array Mirror, Extendible Large Aperture (PAMELA) testbed at MSFC resulting in a 40 to 5OX improvement in SNR which in turn enabled NASA personnel to achieve many significant strides in improved closed-loop system operation in 1998. 5) A new system level processor was built and delivered to MSFC for use with the PAMELA testbed. This new system featured a new graphical user interface to replace the obsolete and non-supported menu system originally delivered with the PAMELA system. The hardware featured Blue Line's new stackable processing system which included fiber optic data links, a WFS digital interface, and a very compact and reliable electronics package. The project also resulted in substantial advances in the evolution of concepts for integrated structures to be used to support clusters of segments while also serving as the means to distribute power, timing, and data communications resources. A prototype cluster base was built and delivered that would support a small array of 7 cm mirror segments. Another conceptual design effort led to substantial progress in the area of laminated silicon mirror segments. While finished mirrors were never successfully produced in this exploratory effort, the basic feasibility of the concept was established through a significant amount of experimental development in microelectronics processing laboratories at the University of Colorado in Colorado Springs. Ultimately lightweighted aluminum mirrors with replicated front surfaces were produced and delivered as part of a separate contract to develop integrated segmented mirror assemblies. Overall the project was very successful in advancing segmented mirror system architectures on several fronts. In fact, the results of this work have already served as the basic foundation for the system architectures of several projects proposed by Blue Line for different missions and customers. These include the NMSD and AMSD procurements for NASA's Next Generation Space Telescope, the HET figure maintenance system, and the 1 meter FAST telescope project.

  1. Volcanic evolution of an active magmatic rift segment on a 100 Kyr timescale: exposure dating of lavas from the Manda Hararo/Dabbahu segment of the Afar Rift

    NASA Astrophysics Data System (ADS)

    Medynski, S.; Williams, A.; Pik, R.; Burnard, P.; Vye, C.; France, L.; Ayalew, D.; Yirgu, G.

    2012-12-01

    In the Afar depression (Ethiopia), extension is already organised along rift segments which morphologically resemble oceanic rifts. Segmentation here results from interactions between dyke injection and volcanism, as observed during the well documented 2005 event on the Dabbahu rift segment. During this tectono-volcanic crisis, a megadyke was injected, followed by 12 subsequent dike intrusions, sometimes associated with fissure flow eruptions. Despite the accurate surveying of the magmatic and tectonic interplay during this event via remote sensing techniques, there is a lack of data on timescales of 1 to 100 kyr, the period over which the main morphology of a rift is acquired. The Dabbahu rift segment represents an ideal natural laboratory to study the evolution of rift morphology as a response to volcanic and tectonic influences. It is possible to constrain the timing of fault growth relative to the infilling of the rift axial depression by lava flows, and to assess the influence of the different magma bodies involved in lava production along the rift-segment. We use cosmogenic nuclides (3He) to determine the ages of young (<100 kyr) lava flows and to date the initiation and movement of fault scarps which cut the lavas. Combined with major & trace element compositions, field mapping and digital cartography (Landsat, ASTER and SPOT imagery), the rift geomorphology can be linked to the magmatic and tectonic history defined by surface exposure dating. The results show that over the last 100 ka the Northern part of the Dabbahu segment was supplied by two different magma reservoirs which can be identified based on their distinctive chemistries. The main reservoir is located beneath Dabbahu volcano, and has been supplied with magma for at least 72 ka. This magmatic centre supplies magma to most of the northern third of the rift segment. The second reservoir is located further south, on the axis, close to the current mid-segment magma chamber, which was responsible for the 2005 rifting episode. This second magmatic centre supplies magma to the remaining 2/3 of the segment, but scarcely impacts its Northern termination (where the Dabbahu activity predominates) - except during extraordinary events when dykes are long enough to reach those parts, as in 2005. The eruption ages of the different lava units correlates with their degrees of differentiation, allowing different magmatic cycles of about a few tens of years each to be distinguished. During the first recorded magmatic cycle (~70 ka to ~55 ka), Dabbahu is built of wide-spreading pāhoehoe flows around localised eruptive centres. The resulting topography of the volcanic edifice remains low, and is only slightly affected by rift-related fault activity, with the development of minor scarps. The second recorded magmatic cycle (~50 ka to ~20 ka) coincides with a strong development of Dabbahu topography - underlined by the change in lava morphology with well channelized 'a'ā flows since 50 ka. Tectonic activity also clearly increases over this period, with the initiation of the major fault scarps of the rift, which have been dated at around 35 ka. Our study underlines the role of the magma supply and availability beneath Dabbahu in the evolution both topographies of Dabbahu volcano and of the rift depression morphology.

  2. Turbine stator vane segment having internal cooling circuits

    DOEpatents

    Jones, Raymond Joseph; Burns, James Lee; Bojappa, Parvangada Ganapathy; Jones, Schotsch Margaret

    2003-01-01

    A turbine stator vane includes outer and inner walls each having outer and inner chambers and a vane extending between the outer and inner walls. The vane includes first, second, third, fourth and fifth cavities for flowing a cooling medium. The cooling medium enters the outer chamber of the outer wall, flows through an impingement plate for impingement cooling of the outer band wall defining in part the hot gas path and through openings in the first, second and fourth cavities for flow radially inwardly, cooling the vane. The spent cooling medium flows into the inner wall and inner chamber for flow through an impingement plate radially outwardly to cool the inner wall. The spent cooling medium flows through the third cavity for egress from the turbine vane segment from the outer wall. The first, second or third cavities contain inserts having impingement openings for impingement cooling of the vane walls. The fifth cavity provides air cooling for the trailing edge.

  3. Survivorship analysis of failure pattern after revision total hip arthroplasty.

    PubMed

    Retpen, J B; Varmarken, J E; Jensen, J S

    1989-12-01

    Failure, defined as established indication for or performed re-revision of one or both components, was analyzed using survivorship methods in 306 revision total hip arthroplasties. The longevity of revision total hip arthroplasties was inferior to that of previously reported primary total hip arthroplasties. The overall survival curve was two-phased, with a late failure period associated with aseptic loosening of one or both components and an early failure period associated with causes of failure other than loosening. Separate survival curves for aseptic loosening of femoral and acetabular components showed late and almost simultaneous decline, but with a tendency toward a higher rate of failure for the femoral component. No differences in survival could be found between the Stanmore, Lubinus standard, and Lubinus long-stemmed femoral components. A short interval between the index operation and the revision and intraoperative and postoperative complications were risk factors for early failure. Young age was a risk factor for aseptic loosening of the femoral component. Intraoperative fracture of the femoral shaft was not a risk factor for secondary loosening. No difference in survival was found between primary cemented total arthroplasty and primary noncemented hemiarthroplasty.

  4. Cerebrospinal fluid lactate level as a diagnostic biomarker for bacterial meningitis in children

    PubMed Central

    2014-01-01

    Background Cerebrospinal fluid (CSF) lactate is a potential biomarker for bacterial meningitis in children. To this end, we performed a single-center retrospective cohort study of children from Sao Paulo, Brazil, with CSF pleocytosis to evaluate the ability of CSF lactate to distinguish between children with bacterial and aseptic meningitis. We determined the optimum cutoff point for CSF lactate using receiver-operator curve (ROC) analysis. Findings We identified 451 children of whom 40 (9%) had bacterial meningitis. Children with bacterial meningitis had a higher median CSF lactate level [9.6 mmol/l, interquartile range (IQR) 3.2-38.5 mmol/l bacterial meningitis vs. 2.0 mmol/l, IQR 1.2-2.8 mmol/l aseptic meningitis]. A CSF lactate cutoff point of 3.0 mmol/l had a sensitivity of 95% [95% confidence interval (CI) 83-99%), specificity of 94% (95% CI 90-96%) and negative predictive value of 99.3% (95% CI 97.7-99.9%) for bacterial meningitis. Conclusions In combination with a validated meningitis clinical prediction rule, the CSF lactate level can be used to distinguish between bacterial and aseptic meningitis in children with CSF pleocytosis. PMID:24576334

  5. Cerebrospinal fluid lactate level as a diagnostic biomarker for bacterial meningitis in children.

    PubMed

    Mekitarian Filho, Eduardo; Horita, Sérgio Massaru; Gilio, Alfredo Elias; Nigrovic, Lise E

    2014-02-27

    Cerebrospinal fluid (CSF) lactate is a potential biomarker for bacterial meningitis in children. To this end, we performed a single-center retrospective cohort study of children from Sao Paulo, Brazil, with CSF pleocytosis to evaluate the ability of CSF lactate to distinguish between children with bacterial and aseptic meningitis. We determined the optimum cutoff point for CSF lactate using receiver-operator curve (ROC) analysis. We identified 451 children of whom 40 (9%) had bacterial meningitis. Children with bacterial meningitis had a higher median CSF lactate level [9.6 mmol/l, interquartile range (IQR) 3.2-38.5 mmol/l bacterial meningitis vs. 2.0 mmol/l, IQR 1.2-2.8 mmol/l aseptic meningitis]. A CSF lactate cutoff point of 3.0 mmol/l had a sensitivity of 95% [95% confidence interval (CI) 83-99%), specificity of 94% (95% CI 90-96%) and negative predictive value of 99.3% (95% CI 97.7-99.9%) for bacterial meningitis. In combination with a validated meningitis clinical prediction rule, the CSF lactate level can be used to distinguish between bacterial and aseptic meningitis in children with CSF pleocytosis.

  6. Discrimination between platelet-mediated and coagulation-mediated mechanisms in a model of complex thrombus formation in vivo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cadroy, Y.; Horbett, T.A.; Hanson, S.R.

    1989-04-01

    To study mechanisms of complex thrombus formation in vivo, and to compare the relative antithrombotic effects of anticoagulants and antiplatelet agents, a model was developed in baboons. Segments of collagen-coated tubing followed by two sequentially placed expansion chambers exhibiting disturbed flow patterns were exposed to native blood under laminar flow conditions. The device was incorporated for 1 hour into an exteriorized arteriovenous shunt in baboons under controlled blood flow (20 ml/min). Morphologic evaluation by scanning electron microscopy showed that thrombi associated with collagen were relatively rich in platelets but thrombi in the chambers were rich in fibrin and red cells.more » Deposition of indium 111-labeled platelets was continuously measured with a scintillation camera. Platelet deposition increased in a linear (collagen-coated segment) or exponential (chambers 1 and 2) fashion over time, with values after 40 minutes averaging 24.1 +/- 3.3 x 10(8) platelets (collagen segment), 16.7 +/- 3.4 x 10(8) platelets (chamber 1), and 8.4 +/- 2.4 x 10(8) platelets (chamber 2). Total fibrinogen deposition after 40 minutes was determined by using iodine 125-labeled baboon fibrinogen and averaged 0.58 +/- 0.14 mg in the collagen segment, 1.51 +/- 0.27 mg in chamber 1, and 0.95 +/- 0.25 mg in chamber 2. Plasma levels of beta-thromboglobulin (beta TG), platelet-factor 4 (PF4), and fibrinopeptide A (FPA) increased fourfold to fivefold after 60 minutes of blood exposure to the thrombotic device. Platelet deposition onto the collagen segment, chamber 1, and chamber 2 was linearly dependent on the circulating platelet count. Platelet accumulation in chamber 1 and chamber 2 was also dependent on the presence of the proximal collagen segment.« less

  7. Repeatability of Non-Contrast-Enhanced Lower-Extremity Angiography Using the Flow-Spoiled Fresh Blood Imaging.

    PubMed

    Zhang, Yuyang; Xing, Zhen; She, Dejun; Huang, Nan; Cao, Dairong

    The aim of this study was to prospectively evaluate the repeatability of non-contrast-enhanced lower-extremity magnetic resonance angiography using the flow-spoiled fresh blood imaging (FS-FBI). Forty-three healthy volunteers and 15 patients with lower-extremity arterial stenosis were recruited in this study and were examined by FS-FBI. Digital subtraction angiography was performed within a week after the FS-FBI in the patient group. Repeatability was assessed by the following parameters: grading of image quality, diameter and area of major arteries, and grading of stenosis of lower-extremity arteries. Two experienced radiologists blinded for patient data independently evaluated the FS-FBI and digital subtraction angiography images. Intraclass correlation coefficients (ICCs), sensitivity, and specificity were used for statistical analysis. The grading of image quality of most data was satisfactory. The ICCs for the first and second measures were 0.792 and 0.884 in the femoral segment and 0.803 and 0.796 in the tibiofibular segment for healthy volunteer group, 0.873 and 1.000 in the femoral segment, and 0.737 and 0.737 in the tibiofibular segment for the patient group. Intraobserver and interobserver agreements on diameter and area of arteries were excellent, with ICCs mostly greater than 0.75 in the volunteer group. For stenosis grading analysis, intraobserver ICCs range from 0.784 to 0.862 and from 0.778 to 0.854, respectively. Flow-spoiled fresh blood imaging yielded a mean sensitivity and specificity to detect arterial stenosis or occlusion of 90% and 80% for femoral segment and 86.7% and 93.3% for tibiofibular segment at least. Lower-extremity angiography with FS-FBI is a reliable and reproducible screening tool for lower-extremity atherosclerotic disease, especially for patients with impaired renal function.

  8. Epidemics of viral meningitis caused by echovirus 6 and 30 in Korea in 2008.

    PubMed

    Kim, Hye-Jin; Kang, Byounghak; Hwang, Seoyeon; Hong, Jiyoung; Kim, Kisang; Cheon, Doo-Sung

    2012-02-15

    Enteroviruses (EVs) are the leading cause of aseptic meningitis, which is the most frequent central nervous system infection worldwide. We aimed to characterize the EVs involved in an aseptic meningitis outbreak in Korea in 2008. In Korea, Echovirus type 30 (E30) and E6 have been associated with outbreaks and frequent meningitis. During 2008, through nationwide surveillance, we collected specimens from 758 patients with aseptic meningitis-related clinical manifestations. The detection of EVs from specimens was subjected to a diagnostic real-time RT-PCR in the 5' NCR. A semi-nested polymerase chain reaction (PCR) to amplify sequences from the VP1 region and sequence comparison with reference strains registered in Genbank was performed for the genotype determination. Most patients (98%) in this outbreak were children < 15 years of age. The temporal distribution of the E6 and E30 epidemics showed an obvious seasonal pattern during the short period from June to July. A large majority of the EV-positive patients experienced fever, headache, vomiting, and neck stiffness. Some patients also showed cold symptoms, sore throat, altered mental status, and seizures. We did not observe a higher fatality rate in children with E6 or E30 infection. Most of the patients recovered uneventfully. In most cases, the cerebrospinal fluid (CSF) profile was studied, and generally showed a higher than normal white blood cell count (≥ 5/mm(3)). We detected EVs from 513 patients (67.68%) and identified the EV genotype in 287 patients. E30 (n = 155, 50.4%) and E6 (n = 95, 33.1%) were the predominant genotypes. E9, E1, E7, E16, coxsackievirus A3, 4, 6, coxsackievirus B1, 3, and 10 were also identified. According to phylogenetic analysis, E30 belonged to subgroup 4b, and E6, to the C4 subgroup. Conclusively, aseptic meningitis was the most common manifestation in children with either echovirus 30 or 6 infection. Identification of E6 and E30 as the prominent EVs in the 2008 outbreak in South Korea shows the potential of EVs to cause a serious disease in an unpredictable (fashion. Our findings provide new) insights into the clinical and virological features of the aseptic meningitis outbreak caused by E30 and E6.

  9. Epidemics of viral meningitis caused by echovirus 6 and 30 in Korea in 2008

    PubMed Central

    2012-01-01

    Background Enteroviruses (EVs) are the leading cause of aseptic meningitis, which is the most frequent central nervous system infection worldwide. We aimed to characterize the EVs involved in an aseptic meningitis outbreak in Korea in 2008. In Korea, Echovirus type 30 (E30) and E6 have been associated with outbreaks and frequent meningitis. Methods During 2008, through nationwide surveillance, we collected specimens from 758 patients with aseptic meningitis-related clinical manifestations. The detection of EVs from specimens was subjected to a diagnostic real-time RT-PCR in the 5' NCR. A semi-nested polymerase chain reaction (PCR) to amplify sequences from the VP1 region and sequence comparison with reference strains registered in Genbank was performed for the genotype determination. Results Most patients (98%) in this outbreak were children < 15 years of age. The temporal distribution of the E6 and E30 epidemics showed an obvious seasonal pattern during the short period from June to July. A large majority of the EV-positive patients experienced fever, headache, vomiting, and neck stiffness. Some patients also showed cold symptoms, sore throat, altered mental status, and seizures. We did not observe a higher fatality rate in children with E6 or E30 infection. Most of the patients recovered uneventfully. In most cases, the cerebrospinal fluid (CSF) profile was studied, and generally showed a higher than normal white blood cell count (≥ 5/mm3). We detected EVs from 513 patients (67.68%) and identified the EV genotype in 287 patients. E30 (n = 155, 50.4%) and E6 (n = 95, 33.1%) were the predominant genotypes. E9, E1, E7, E16, coxsackievirus A3, 4, 6, coxsackievirus B1, 3, and 10 were also identified. According to phylogenetic analysis, E30 belonged to subgroup 4b, and E6, to the C4 subgroup. Conclusions Conclusively, aseptic meningitis was the most common manifestation in children with either echovirus 30 or 6 infection. Identification of E6 and E30 as the prominent EVs in the 2008 outbreak in South Korea shows the potential of EVs to cause a serious disease in an unpredictable (fashion. Our findings provide new) insights into the clinical and virological features of the aseptic meningitis outbreak caused by E30 and E6. PMID:22336050

  10. Simulation of blood flow in deformable vessels using subject-specific geometry and spatially varying wall properties

    PubMed Central

    Xiong, Guanglei; Figueroa, C. Alberto; Xiao, Nan; Taylor, Charles A.

    2011-01-01

    SUMMARY Simulation of blood flow using image-based models and computational fluid dynamics has found widespread application to quantifying hemodynamic factors relevant to the initiation and progression of cardiovascular diseases and for planning interventions. Methods for creating subject-specific geometric models from medical imaging data have improved substantially in the last decade but for many problems, still require significant user interaction. In addition, while fluid–structure interaction methods are being employed to model blood flow and vessel wall dynamics, tissue properties are often assumed to be uniform. In this paper, we propose a novel workflow for simulating blood flow using subject-specific geometry and spatially varying wall properties. The geometric model construction is based on 3D segmentation and geometric processing. Variable wall properties are assigned to the model based on combining centerline-based and surface-based methods. We finally demonstrate these new methods using an idealized cylindrical model and two subject-specific vascular models with thoracic and cerebral aneurysms. PMID:21765984

  11. 8. Inverted siphon structure carrying ditch flow under Willow Creek, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Inverted siphon structure carrying ditch flow under Willow Creek, looking southwest - Natomas Ditch System, Blue Ravine Segment, Juncture of Blue Ravine & Green Valley Roads, Folsom, Sacramento County, CA

  12. 7. Inverted siphon structure carrying ditch flow under Willow Creek, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Inverted siphon structure carrying ditch flow under Willow Creek, looking east - Natomas Ditch System, Blue Ravine Segment, Juncture of Blue Ravine & Green Valley Roads, Folsom, Sacramento County, CA

  13. Fast interactive exploration of 4D MRI flow data

    NASA Astrophysics Data System (ADS)

    Hennemuth, A.; Friman, O.; Schumann, C.; Bock, J.; Drexl, J.; Huellebrand, M.; Markl, M.; Peitgen, H.-O.

    2011-03-01

    1- or 2-directional MRI blood flow mapping sequences are an integral part of standard MR protocols for diagnosis and therapy control in heart diseases. Recent progress in rapid MRI has made it possible to acquire volumetric, 3-directional cine images in reasonable scan time. In addition to flow and velocity measurements relative to arbitrarily oriented image planes, the analysis of 3-dimensional trajectories enables the visualization of flow patterns, local features of flow trajectories or possible paths into specific regions. The anatomical and functional information allows for advanced hemodynamic analysis in different application areas like stroke risk assessment, congenital and acquired heart disease, aneurysms or abdominal collaterals and cranial blood flow. The complexity of the 4D MRI flow datasets and the flow related image analysis tasks makes the development of fast comprehensive data exploration software for advanced flow analysis a challenging task. Most existing tools address only individual aspects of the analysis pipeline such as pre-processing, quantification or visualization, or are difficult to use for clinicians. The goal of the presented work is to provide a software solution that supports the whole image analysis pipeline and enables data exploration with fast intuitive interaction and visualization methods. The implemented methods facilitate the segmentation and inspection of different vascular systems. Arbitrary 2- or 3-dimensional regions for quantitative analysis and particle tracing can be defined interactively. Synchronized views of animated 3D path lines, 2D velocity or flow overlays and flow curves offer a detailed insight into local hemodynamics. The application of the analysis pipeline is shown for 6 cases from clinical practice, illustrating the usefulness for different clinical questions. Initial user tests show that the software is intuitive to learn and even inexperienced users achieve good results within reasonable processing times.

  14. Stereo imaging velocimetry for microgravity applications

    NASA Technical Reports Server (NTRS)

    Miller, Brian B.; Meyer, Maryjo B.; Bethea, Mark D.

    1994-01-01

    Stereo imaging velocimetry is the quantitative measurement of three-dimensional flow fields using two sensors recording data from different vantage points. The system described in this paper, under development at NASA Lewis Research Center in Cleveland, Ohio, uses two CCD cameras placed perpendicular to one another, laser disk recorders, an image processing substation, and a 586-based computer to record data at standard NTSC video rates (30 Hertz) and reduce it offline. The flow itself is marked with seed particles, hence the fluid must be transparent. The velocimeter tracks the motion of the particles, and from these we deduce a multipoint (500 or more), quantitative map of the flow. Conceptually, the software portion of the velocimeter can be divided into distinct modules. These modules are: camera calibration, particle finding (image segmentation) and centroid location, particle overlap decomposition, particle tracking, and stereo matching. We discuss our approach to each module, and give our currently achieved speed and accuracy for each where available.

  15. Accelerated gas-liquid visible light photoredox catalysis with continuous-flow photochemical microreactors.

    PubMed

    Straathof, Natan J W; Su, Yuanhai; Hessel, Volker; Noël, Timothy

    2016-01-01

    In this protocol, we describe the construction and use of an operationally simple photochemical microreactor for gas-liquid photoredox catalysis using visible light. The general procedure includes details on how to set up the microreactor appropriately with inlets for gaseous reagents and organic starting materials, and it includes examples of how to use it to achieve continuous-flow preparation of disulfides or trifluoromethylated heterocycles and thiols. The reported photomicroreactors are modular, inexpensive and can be prepared rapidly from commercially available parts within 1 h even by nonspecialists. Interestingly, typical reaction times of gas-liquid visible light photocatalytic reactions performed in microflow are lower (in the minute range) than comparable reactions performed as a batch process (in the hour range). This can be attributed to the improved irradiation efficiency of the reaction mixture and the enhanced gas-liquid mass transfer in the segmented gas-liquid flow regime.

  16. A novel star extraction method based on modified water flow model

    NASA Astrophysics Data System (ADS)

    Zhang, Hao; Niu, Yanxiong; Lu, Jiazhen; Ouyang, Zibiao; Yang, Yanqiang

    2017-11-01

    Star extraction is the essential procedure for attitude measurement of star sensor. The great challenge for star extraction is to segment star area exactly from various noise and background. In this paper, a novel star extraction method based on Modified Water Flow Model(MWFM) is proposed. The star image is regarded as a 3D terrain. The morphology is adopted for noise elimination and Tentative Star Area(TSA) selection. Star area can be extracted through adaptive water flowing within TSAs. This method can achieve accurate star extraction with improved efficiency under complex conditions such as loud noise and uneven backgrounds. Several groups of different types of star images are processed using proposed method. Comparisons with existing methods are conducted. Experimental results show that MWFM performs excellently under different imaging conditions. The star extraction rate is better than 95%. The star centroid accuracy is better than 0.075 pixels. The time-consumption is also significantly reduced.

  17. Hydrogeomorphic and hydraulic habitats of the Niobrara River, Nebraska-with special emphasis on the Niobrara National Scenic River

    USGS Publications Warehouse

    Alexander, Jason S.; Zelt, Ronald B.; Schaepe, Nathan J.

    2010-01-01

    The Niobrara River is an ecologically and economically important resource in Nebraska. The Nebraska Department of Natural Resources' recent designation of the hydraulically connected surface- and groundwater resources of the Niobrara River Basin as ?fully appropriated? has emphasized the importance of understanding linkages between the physical and ecological dynamics of the Niobrara River so it can be sustainably managed. In cooperation with the Nebraska Game and Parks Commission, the U.S. Geological Survey investigated the hydrogeomorphic and hydraulic attributes of the Niobrara River in northern Nebraska. This report presents the results of an analysis of hydrogeomorphic segments and hydraulic microhabitats of the Niobrara River and its valley for the approximately 330-mile reach from Dunlap Diversion Dam to its confluence with the Missouri River. Two spatial scales were used to examine and quantify the hydrogeomorphic segments and hydraulic microhabitats of the Niobrara River: a basin scale and a reach scale. At the basin scale, digital spatial data and hydrologic data were analyzed to (1) test for differences between 36 previously determined longitudinal hydrogeomorphic segments; (2) quantitatively describe the hydrogeomorphic characteristics of the river and its valley; and (3) evaluate differences in hydraulic microhabitat over a range of flow regimes among three fluvial geomorphic provinces. The statistical analysis of hydrogeomorphic segments resulted in reclassification rates of 3 to 28 percent of the segments for the four descriptive geomorphic elements. The reassignment of classes by discriminant analysis resulted in a reduction from 36 to 25 total hydrogeomorphic segments because several adjoining segments shared the same ultimate class assignments. Virtually all of the segment mergers were in the Canyons and Restricted Bottoms (CRB) fluvial geomorphic province. The most frequent classes among hydrogeomorphic segments, and the dominant classes per unit length of river, are: a width-restricted valley confinement condition, sinuous-planview pattern, irregular channel width, and an alternate bar configuration. The Niobrara River in the study area flows through a diversity of fluvial geomorphic settings in its traverse across northern Nebraska. In the Meandering Bottoms (MB) fluvial geomorphic province, river discharge magnitudes are low, and the valley exerts little control on the channel-planview pattern. Within the CRB province, the river flows over a diversity of geologic formations, and the valley and river narrow and expand in approximate synchronicity. In the Braided Bottoms (BB) fluvial geomorphic province, the river primarily flows over Cretaceous Pierre Shale, the valley and channel are persistently wide, and the channel slope is generally uniform. The existence of vegetated islands and consequent multithread channel environments, indicated by a higher braided index, mostly coincided with reaches having gentler slopes and less unit stream power. Longitudinal hydrology curves indicate that the flow of the Niobrara River likely is dominated by groundwater as far downstream as Norden. Unit stream power values in the study area vary between 0 and almost 2 pounds per foot per second. Within the MB province, unit stream power steadily increases as the Niobrara gains discharge from groundwater inflow, and the channel slope steepens. The combination of steep slopes, a constrained channel width, and persistent flow within the CRB province results in unit stream power values that are between three and five times greater than those in less confined segments with comparable or greater discharges. With the exception of hydrogeomorphic segment 3, which is affected by Spencer Dam, unit stream power values in the BB province are generally uniform. Channel sinuosity values in the study area varied generally between 1 and 2.5, but with locally higher values measured in the MB province and at the entrenched bedrock me

  18. Multiple Vehicle Detection and Segmentation in Malaysia Traffic Flow

    NASA Astrophysics Data System (ADS)

    Fariz Hasan, Ahmad; Fikri Che Husin, Mohd; Affendi Rosli, Khairul; Norhafiz Hashim, Mohd; Faiz Zainal Abidin, Amar

    2018-03-01

    Vision based system are widely used in the field of Intelligent Transportation System (ITS) to extract a large amount of information to analyze traffic scenes. By rapid number of vehicles on the road as well as significant increase on cameras dictated the need for traffic surveillance systems. This system can take over the burden some task was performed by human operator in traffic monitoring centre. The main technique proposed by this paper is concentrated on developing a multiple vehicle detection and segmentation focusing on monitoring through Closed Circuit Television (CCTV) video. The system is able to automatically segment vehicle extracted from heavy traffic scene by optical flow estimation alongside with blob analysis technique in order to detect the moving vehicle. Prior to segmentation, blob analysis technique will compute the area of interest region corresponding to moving vehicle which will be used to create bounding box on that particular vehicle. Experimental validation on the proposed system was performed and the algorithm is demonstrated on various set of traffic scene.

  19. Apparatus and methods for impingement cooling of a side wall of a turbine nozzle segment

    DOEpatents

    Burdgick, Steven Sebastian

    2002-01-01

    A gas turbine nozzle segment has outer and inner bands and a vane therebetween. Each band includes a nozzle wall, a side wall, a cover and an impingement plate between the cover and the nozzle wall defining two cavities on opposite sides of the impingement plate. Cooling steam is supplied to one cavity for flow through apertures of the impingement plate to cool the nozzle wall. The side wall of the band and inturned flange define with the nozzle wall an undercut region. The impingement plate has a turned flange welded to the inturned flange. A backing plate overlies the turned flange and aligned apertures are formed through the backing plate and turned flange to direct and focus cooling flow onto the side wall of the nozzle segment.

  20. Unsteady Aerodynamic Flow Control of Moving Platforms

    DTIC Science & Technology

    2014-05-29

    aerodynamic forces and moments effected by fluidic actuation on the flow boundaries of stationary and moving platforms. Aerodynamic forces and...Control is effected fluidically by interactions of azimuthally- and streamwise-segmented individually-addressable synthetic jet actuators with...fundamental flow mechanisms that are associated with transitory aerodynamic forces and moments effected by fluidic actuation on the flow boundaries of

  1. Effect of Oxygen addition on altitude blowout and relight of an experimental combustor segment

    NASA Technical Reports Server (NTRS)

    Norgren, C. T.; Ingebo, R. D.

    1974-01-01

    The effect of oxygen addition on the low pressure altitude blowout limits of an experimental combustor segment was investigated. Data were obtained for two inlet-air temperatures, two inlet-airflow rates, and a constant fuel-air ratio of 0.020 with Jet A fuel. It was shown that the pressure at blowout could be reduced to correspond to an increase in altitude of 4.6 kilometers with oxygen flow rates of 8 to 16 percent by weight of the total fuel flow.

  2. Estimation of monthly water yields and flows for 1951-2012 for the United States portion of the Great Lakes Basin with AFINCH

    USGS Publications Warehouse

    Luukkonen, Carol L.; Holtschlag, David J.; Reeves, Howard W.; Hoard, Christopher J.; Fuller, Lori M.

    2015-01-01

    Monthly water yields from 105,829 catchments and corresponding flows in 107,691 stream segments were estimated for water years 1951–2012 in the Great Lakes Basin in the United States. Both sets of estimates were computed by using the Analysis of Flows In Networks of CHannels (AFINCH) application within the NHDPlus geospatial data framework. AFINCH provides an environment to develop constrained regression models to integrate monthly streamflow and water-use data with monthly climatic data and fixed basin characteristics data available within NHDPlus or supplied by the user. For this study, the U.S. Great Lakes Basin was partitioned into seven study areas by grouping selected hydrologic subregions and adjoining cataloguing units. This report documents the regression models and data used to estimate monthly water yields and flows in each study area. Estimates of monthly water yields and flows are presented in a Web-based mapper application. Monthly flow time series for individual stream segments can be retrieved from the Web application and used to approximate monthly flow-duration characteristics and to identify possible trends.

  3. Comparison of sensory, microbiological, and biochemical parameters of microwave versus indirect UHT fluid skim milk during storage.

    PubMed

    Clare, D A; Bang, W S; Cartwright, G; Drake, M A; Coronel, P; Simunovic, J

    2005-12-01

    Shelf-stable milk could benefit from sensory quality improvement. Current methods of heating cause flavor and nutrient degradation through exposure to overheated thermal exchange surfaces. Rapid heating with microwaves followed by sudden cooling could reduce or eliminate this problem. The objectives for this study were focused on designing and implementing continuous microwave thermal processing of skim fluid milks (white and chocolate) to compare sensory, microbiological, and biochemical parameters with conventionally prepared, indirect UHT milks. All test products were aseptically packaged and stored at ambient temperature for 12 mo. Every 3 mo, samples were taken for microbiological testing, reactive sulfhydryl determinations, active enzyme analysis, instrumental viscosity readings, color measurements, and descriptive sensory evaluation. Microbiological plate counts were negative on all milks at each time point. Enzymatic assays showed that plasmin was inactivated by both heat treatments. 5,5'-dithio-bis(2-nitrobenzoic acid) analysis, a measure of reactive sulfhydryl (-SH-) groups, showed that the initial thiol content was not significantly different between the microwave-processed and UHT-treated milks. However, both heating methods resulted in an increased thiol level compared with conventionally pasteurized milk samples due to the higher temperatures attained. Sulfhydryl oxidase, a milk enzyme that catalyzes disulfide bond formation using a variety of protein substrates, retained activity following microwave processing, and decreased during storage. Viscosity values were essentially equivalent in microwave- and UHT-heated white skim milks. Sensory analyses established that UHT-treated milks were visibly darker, and exhibited higher caramelized and stale/fatty flavors with increased astringency compared with the microwave samples. Sweet aromatic flavor and sweet taste decreased during storage in both UHT and microwave milk products, whereas stale/fatty flavors increased over time. Sensory effects were more apparent in white milks than in chocolate varieties. These studies suggest that microwave technology may provide a useful alternative processing method for delivery of aseptic milk products that retain a long shelf life.

  4. Fish habitat regression under water scarcity scenarios in the Douro River basin

    NASA Astrophysics Data System (ADS)

    Segurado, Pedro; Jauch, Eduardo; Neves, Ramiro; Ferreira, Teresa

    2015-04-01

    Climate change will predictably alter hydrological patterns and processes at the catchment scale, with impacts on habitat conditions for fish. The main goals of this study are to identify the stream reaches that will undergo more pronounced flow reduction under different climate change scenarios and to assess which fish species will be more affected by the consequent regression of suitable habitats. The interplay between changes in flow and temperature and the presence of transversal artificial obstacles (dams and weirs) is analysed. The results will contribute to river management and impact mitigation actions under climate change. This study was carried out in the Tâmega catchment of the Douro basin. A set of 29 Hydrological, climatic, and hydrogeomorphological variables were modelled using a water modelling system (MOHID), based on meteorological data recorded monthly between 2008 and 2014. The same variables were modelled considering future climate change scenarios. The resulting variables were used in empirical habitat models of a set of key species (brown trout Salmo trutta fario, barbell Barbus bocagei, and nase Pseudochondrostoma duriense) using boosted regression trees. The stream segments between tributaries were used as spatial sampling units. Models were developed for the whole Douro basin using 401 fish sampling sites, although the modelled probabilities of species occurrence for each stream segment were predicted only for the Tâmega catchment. These probabilities of occurrence were used to classify stream segments into suitable and unsuitable habitat for each fish species, considering the future climate change scenario. The stream reaches that were predicted to undergo longer flow interruptions were identified and crossed with the resulting predictive maps of habitat suitability to compute the total area of habitat loss per species. Among the target species, the brown trout was predicted to be the most sensitive to habitat regression due to the interplay of flow reduction, increase of temperature and transversal barriers. This species is therefore a good indicator of climate change impacts in rivers and therefore we recommend using this species as a target of monitoring programs to be implemented in the context of climate change adaptation strategies.

  5. Potential of Continuous Manufacturing for Liposomal Drug Products.

    PubMed

    Worsham, Robert D; Thomas, Vaughan; Farid, Suzanne S

    2018-05-21

    Over the last several years, continuous manufacturing of pharmaceuticals has evolved from bulk APIs and solid oral dosages into the more complex realm of biologics. The development of continuous downstream processing techniques has allowed biologics manufacturing to realize the benefits (e.g. improved economics, more consistent quality) that come with continuous processing. If relevant processing techniques and principles are selected, the opportunity arises to develop continuous manufacturing designs for additional pharmaceutical products including liposomal drug formulations. Liposome manufacturing has some inherent aspects that make it favorable for a continuous process. Other aspects such as formulation refinement, materials of construction, and aseptic processing need development, but present an achievable challenge. This paper reviews the current state of continuous manufacturing technology applicable to liposomal drug product manufacturing and an assessment of the challenges and potential of this application. This article is protected by copyright. All rights reserved.

  6. Respiratory Sound Analysis for Flow Estimation During Wakefulness and Sleep, and its Applications for Sleep Apnea Detection and Monitoring

    NASA Astrophysics Data System (ADS)

    Yadollahi, Azadeh

    Tracheal respiratory sounds analysis has been investigated as a non--invasive method to estimate respiratory flow and upper airway obstruction. However, the flow--sound relationship is highly variable among subjects which makes it challenging to estimate flow in general applications. Therefore, a robust model for acoustical flow estimation in a large group of individuals did not exist before. On the other hand, a major application of acoustical flow estimation is to detect flow limitations in patients with obstructive sleep apnea (OSA) during sleep. However, previously the flow--sound relationship was only investigated during wakefulness among healthy individuals. Therefore, it was necessary to examine the flow--sound relationship during sleep in OSA patients. This thesis takes the above challenges and offers innovative solutions. First, a modified linear flow--sound model was proposed to estimate respiratory flow from tracheal sounds. To remove the individual based calibration process, the statistical correlation between the model parameters and anthropometric features of 93 healthy volunteers was investigated. The results show that gender, height and smoking are the most significant factors that affect the model parameters. Hence, a general acoustical flow estimation model was proposed for people with similar height and gender. Second, flow--sound relationship during sleep and wakefulness was studied among 13 OSA patients. The results show that during sleep and wakefulness, flow--sound relation- ship follows a power law, but with different parameters. Therefore, for acoustical flow estimation during sleep, the model parameters should be extracted from sleep data to have small errors. The results confirm reliability of the acoustical flow estimation for investigating flow variations during both sleep and wakefulness. Finally, a new method for sleep apnea detection and monitoring was developed, which only requires recording the tracheal sounds and the blood's oxygen saturation level (SaO2) data. It automatically classifies the sound segments into breath, snore and noise. A weighted average of features extracted from sound segments and SaO2 signal was used to detect apnea and hypopnea events. The performance of the proposed approach was evaluated on the data of 66 patients. The results show high correlation (0.96, p < 0.0001) between the outcomes of our system and those of the polysomnography. Also, sensitivity and specificity of the proposed method in differentiating simple snorers from OSA patients were found to be more than 91%. These results are superior or comparable with the existing commercialized sleep apnea portable monitors.

  7. Assessing SPO techniques to constrain magma flow: Examples from sills of the Karoo Igneous Province, South Africa

    NASA Astrophysics Data System (ADS)

    Hoyer, Lauren; Watkeys, Michael K.

    2015-08-01

    Shape ellipsoids that define the petrofabrics of plagioclase in Jurassic Karoo dolerite sills in KwaZulu-Natal, South Africa are rigorously constrained using the long axis lengths of plagioclase crystals and ellipse incompatibility. This has been undertaken in order to determine the most effective technique to determine petrofabrics when using the SPO-2003 programme (Launeau and Robin, 2005). The technique of segmenting an image for analysis is scrutinised and as a process is found redundant. A grain size threshold is defined to assist with the varying grain sizes observed within and between sills. Where grains exceed the 0.2 mm size threshold, images should be acquired at a high magnification (i.e., 10 × magnification). Petrofabrics are determined using the foliation and the lineation of the ellipsoid as defined by the maximum and minimum principal axes (respectively) of the resultant ellipsoid. Samples with strongly prolate fabrics are isolated allowing further constraint on the petrofabric to be made. Once the efficacy of the petrofabric determination process has been determined, the resultant foliations (and lineations) then elucidate the most accurate petrofabric attainable. The most accurate petrofabrics will be determined by using the correct magnification when the images are obtained and to run the analyses without segmenting the image. The fabrics of the upper and lower contacts of the Karoo dolerite sills are analysed in detail using these techniques and the fabrics are used as a proxy for magma flow.

  8. Geochemical and Isotopic Variations Along the Southeast Indian Ridge (126°-140°E) Related to Mantle Flow Originating from Beneath Antarctica

    NASA Astrophysics Data System (ADS)

    Hanan, B. B.; Graham, D. W.; Hemond, C.; Dufour, F.; Briais, A.; Ceuleneer, G.; Maia, M.; Park, S. H.; Revillon, S.; Yang, Y. S.

    2017-12-01

    We present data for glassy basalts from 37 localities along the spreading axis of the Southeast Indian Ridge (SEIR) between 126°-140°E, eastward of the Australian-Antarctic Discordance (AAD). Each of the five ridge segments (A1 to A5, west to east) show well-defined major element trends. An isotopic and negative axial depth anomaly is present, centered on the overlapping tips of segments A3 and A4 at 135°E. Segment A4 basalts have distinct radiogenic Pb and He isotopes plus enriched MORB-like ɛHf, relative to segments to the west and east. Crystal fractionation is more extensive at the A3 and A5 overlapping segment tips adjacent to A4, and decreases both to the west and east. The along axis pattern suggests a mantle heterogeneity located beneath the A3-A4 segments. Pb-Pb isotopic co-variations for the 5 segments define two linear arrays, with a western trend (A1-A3) and an eastern trend (A4-A5) that intersects it at the composition of the anomalous A4 segment, at a 206Pb/204Pb 19. The western trend has higher 208Pb/204Pb for a given 206Pb/204Pb, revealing a gradient in the asthenosphere, with Δ208Pb/204Pb decreasing to the east away from the AAD. Overall, 206,207,208Pb/204Pb and 4He/3He of the A4 anomaly define trends that vector toward the fields for Cenozoic lavas from west Antarctica (Marie Byrd Land and Balleny Islands). West Antarctica has a history of mantle plume underplating and lithosphere modification by subduction [1,2], and there is a broad seismic anomaly below 250 km underlying the West Antarctic Rift system [3]. Our data supports a model in which flow of underplated material plus lithosphere may be guided by the underside topography of the lithosphere beneath the Transantarctic mountains. This flow emerges from beneath east Antarctica, where it leads to volcanism in the Balleny Islands [4]. The material apparently continues to flow northward to the SEIR at 135°E. The geochemical anomaly beneath Zone A is potentially explained by the presence of this residual plume/mobilized lithospheric material in the subridge mantle of the SEIR. [1] Hart et al., 1997, Chem Geol 139; [2] Aviado et al. 2015, G3 16; [3] Moelli and Danesi, 2004, GPC 42; [4] Sleep, 2006, ESR 77.

  9. Segmentation of bone structures in 3D CT images based on continuous max-flow optimization

    NASA Astrophysics Data System (ADS)

    Pérez-Carrasco, J. A.; Acha-Piñero, B.; Serrano, C.

    2015-03-01

    In this paper an algorithm to carry out the automatic segmentation of bone structures in 3D CT images has been implemented. Automatic segmentation of bone structures is of special interest for radiologists and surgeons to analyze bone diseases or to plan some surgical interventions. This task is very complicated as bones usually present intensities overlapping with those of surrounding tissues. This overlapping is mainly due to the composition of bones and to the presence of some diseases such as Osteoarthritis, Osteoporosis, etc. Moreover, segmentation of bone structures is a very time-consuming task due to the 3D essence of the bones. Usually, this segmentation is implemented manually or with algorithms using simple techniques such as thresholding and thus providing bad results. In this paper gray information and 3D statistical information have been combined to be used as input to a continuous max-flow algorithm. Twenty CT images have been tested and different coefficients have been computed to assess the performance of our implementation. Dice and Sensitivity values above 0.91 and 0.97 respectively were obtained. A comparison with Level Sets and thresholding techniques has been carried out and our results outperformed them in terms of accuracy.

  10. Morphometric variability within the axial zone of the southern Juan de Fuca Ridge: Interpretation from Sea MARC II, Sea MARC I, and deep-sea photography

    USGS Publications Warehouse

    Kappel, Ellen S.; Normark, William R.

    1987-01-01

    The morphometric characteristics of the axial regions of oceanic spreading centers are determined by (1) the type of volcanic flows, (2) the relation between primary volcanic relief (on a scale of a few meters to tens of meters) and degree of sediment cover, and (3) the extent of surficial expression and timing of tectonic disruption of the young oceanic crust. Even within a single, continuous, linear spreading-ridge segment with relatively uniform axial valley dimensions over a distance of 50 or more kilometers, such as along the southern Juan de Fuca Ridge, the changes in morphometric characteristics along axis within the youngest crust indicate distinct variation in tectonic and volcanic activity over short distances within short time periods. An integrated analysis of Sea MARC I, Sea MARC II, and photographic data for the southernmost continuous segment of the Juan de Fuca Ridge shows that generalizations about tectonic and volcanic processes at spreading ridges must consider both the temporal scale of processes as well as the physical scales of observations if predictive models are to be successful. Comparison of the morphometric expression within the major hydrothermal vent area and the rest of the southernmost ridge segment suggests that the mapped distribution of hydrothermal vents may reflect the extent of survey effort rather than uniqueness of geologic setting.

  11. Segmentation of the pectoral muscle in breast MR images using structure tensor and deformable model

    NASA Astrophysics Data System (ADS)

    Lee, Myungeun; Kim, Jong Hyo

    2012-02-01

    Recently, breast MR images have been used in wider clinical area including diagnosis, treatment planning, and treatment response evaluation, which requests quantitative analysis and breast tissue segmentation. Although several methods have been proposed for segmenting MR images, segmenting out breast tissues robustly from surrounding structures in a wide range of anatomical diversity still remains challenging. Therefore, in this paper, we propose a practical and general-purpose approach for segmenting the pectoral muscle boundary based on the structure tensor and deformable model. The segmentation work flow comprises four key steps: preprocessing, detection of the region of interest (ROI) within the breast region, segmenting the pectoral muscle and finally extracting and refining the pectoral muscle boundary. From experimental results we show that the proposed method can segment the pectoral muscle robustly in diverse patient cases. In addition, the proposed method will allow the application of the quantification research for various breast images.

  12. The remote sensing image segmentation mean shift algorithm parallel processing based on MapReduce

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Zhou, Liqing

    2015-12-01

    With the development of satellite remote sensing technology and the remote sensing image data, traditional remote sensing image segmentation technology cannot meet the massive remote sensing image processing and storage requirements. This article put cloud computing and parallel computing technology in remote sensing image segmentation process, and build a cheap and efficient computer cluster system that uses parallel processing to achieve MeanShift algorithm of remote sensing image segmentation based on the MapReduce model, not only to ensure the quality of remote sensing image segmentation, improved split speed, and better meet the real-time requirements. The remote sensing image segmentation MeanShift algorithm parallel processing algorithm based on MapReduce shows certain significance and a realization of value.

  13. Assessing the impacts of dams and levees on the hydrologic record of the Middle and Lower Mississippi River, USA

    USGS Publications Warehouse

    Remo, Jonathan W.F.; Ickes, Brian; Ryherd, Julia K.; Guida, Ross J.; Therrell, Matthew D.

    2018-01-01

    The impacts of dams and levees on the long-term (>130 years) discharge record was assessed along a ~1200 km segment of the Mississippi River between St. Louis, Missouri, and Vicksburg, Mississippi. To aid in our evaluation of dam impacts, we used data from the U.S. National Inventory of Dams to calculate the rate of reservoir expansion at five long-term hydrologic monitoring stations along the study segment. We divided the hydrologic record at each station into three periods: (1) a pre-rapid reservoir expansion period; (2) a rapid reservoir expansion period; and (3) a post-rapid reservoir expansion period. We then used three approaches to assess changes in the hydrologic record at each station. Indicators of hydrologic alteration (IHA) and flow duration hydrographs were used to quantify changes in flow conditions between the pre- and post-rapid reservoir expansion periods. Auto-regressive interrupted time series analysis (ARITS) was used to assess trends in maximum annual discharge, mean annual discharge, minimum annual discharge, and standard deviation of daily discharges within a given water year. A one-dimensional HEC-RAS hydraulic model was used to assess the impact of levees on flood flows. Our results revealed that minimum annual discharges and low-flow IHA parameters showed the most significant changes. Additionally, increasing trends in minimum annual discharge during the rapid reservoir expansion period were found at three out of the five hydrologic monitoring stations. These IHA and ARITS results support previous findings consistent with the observation that reservoirs generally have the greatest impacts on low-flow conditions. River segment scale hydraulic modeling revealed levees can modestly increase peak flood discharges, while basin-scale hydrologic modeling assessments by the U.S. Army Corps of Engineers showed that tributary reservoirs reduced peak discharges by a similar magnitude (2 to 30%). This finding suggests that the effects of dams and levees on peak flood discharges are in part offsetting one another along the modeled river segments and likely other substantially leveed segments of the Mississippi River.

  14. Assessing the impacts of dams and levees on the hydrologic record of the Middle and Lower Mississippi River, USA

    NASA Astrophysics Data System (ADS)

    Remo, Jonathan W. F.; Ickes, Brian S.; Ryherd, Julia K.; Guida, Ross J.; Therrell, Matthew D.

    2018-07-01

    The impacts of dams and levees on the long-term (>130 years) discharge record was assessed along a 1200 km segment of the Mississippi River between St. Louis, Missouri, and Vicksburg, Mississippi. To aid in our evaluation of dam impacts, we used data from the U.S. National Inventory of Dams to calculate the rate of reservoir expansion at five long-term hydrologic monitoring stations along the study segment. We divided the hydrologic record at each station into three periods: (1) a pre-rapid reservoir expansion period; (2) a rapid reservoir expansion period; and (3) a post-rapid reservoir expansion period. We then used three approaches to assess changes in the hydrologic record at each station. Indicators of hydrologic alteration (IHA) and flow duration hydrographs were used to quantify changes in flow conditions between the pre- and post-rapid reservoir expansion periods. Auto-regressive interrupted time series analysis (ARITS) was used to assess trends in maximum annual discharge, mean annual discharge, minimum annual discharge, and standard deviation of daily discharges within a given water year. A one-dimensional HEC-RAS hydraulic model was used to assess the impact of levees on flood flows. Our results revealed that minimum annual discharges and low-flow IHA parameters showed the most significant changes. Additionally, increasing trends in minimum annual discharge during the rapid reservoir expansion period were found at three out of the five hydrologic monitoring stations. These IHA and ARITS results support previous findings consistent with the observation that reservoirs generally have the greatest impacts on low-flow conditions. River segment scale hydraulic modeling revealed levees can modestly increase peak flood discharges, while basin-scale hydrologic modeling assessments by the U.S. Army Corps of Engineers showed that tributary reservoirs reduced peak discharges by a similar magnitude (2 to 30%). This finding suggests that the effects of dams and levees on peak flood discharges are in part offsetting one another along the modeled river segments and likely other substantially leveed segments of the Mississippi River.

  15. Sedimentation in the central segment of the Aleutian Trench: Sources, transport, and depositional style

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevenson, A.J.; Scholl, D.W.; Vallier, T.L.

    1990-05-01

    The central segment of the Aleutian Trench (162{degree}W to 175{degree}E) is an intraoceanic subduction zone that contains an anomalously thick sedimentary fill (4 km maximum). The fill is an arcward-thickening and slightly tilted wedge of sediment characterized acoustically by laterally continuous, closely spaced, parallel reflectors. These relations are indicative of turbidite deposition. The trench floor and reflection horizons are planar, showing no evidence of an axial channel or any transverse fan bodies. Cores of surface sediment recover turbidite layers, implying that sediment transport and deposition occur via diffuse, sheetlike, fine-grained turbidite flows that occupy the full width of the trench.more » The mineralogy of Holocene trench sediments document a mixture of island-arc (dominant) and continental source terranes. GLORIA side-scan sonar images reveal a westward-flowing axial trench channel that conducts sediment to the eastern margin of the central segment, where channelized flow cases. Much of the sediment transported in this channel is derived from glaciated drainages surrounding the Gulf of Alaska which empty into the eastern trench segment via deep-sea channel systems (Surveyor and others) and submarine canyons (Hinchinbrook and others). Insular sediment transport is more difficult to define. GLORIA images show the efficiency with which the actively growing accretionary wedge impounds sediment that manages to cross a broad fore-arc terrace. It is likely that island-arc sediment reaches the trench either directly via air fall, via recycling of the accretionary prism, or via overtopping of the accretionary ridges by the upper parts of thick turbidite flows.« less

  16. Method of Adjusting Acoustic Impedances for Impedance-Tunable Acoustic Segments

    NASA Technical Reports Server (NTRS)

    Jones, Kennie H (Inventor); Nark, Douglas M. (Inventor); Jones, Michael G. (Inventor); Parrott, Tony L. (Inventor); Lodding, Kenneth N. (Inventor)

    2012-01-01

    A method is provided for making localized decisions and taking localized actions to achieve a global solution. In an embodiment of the present invention, acoustic impedances for impedance-tunable acoustic segments are adjusted. A first acoustic segment through an N-th acoustic segment are defined. To start the process, the first acoustic segment is designated as a leader and a noise-reducing impedance is determined therefor. This is accomplished using (i) one or more metrics associated with the acoustic wave at the leader, and (ii) the metric(s) associated with the acoustic wave at the N-th acoustic segment. The leader, the N-th acoustic segment, and each of the acoustic segments exclusive of the leader and the N-th acoustic segment, are tuned to the noise-reducing impedance. The current leader is then excluded from subsequent processing steps. The designation of leader is then given one of the remaining acoustic segments, and the process is repeated for each of the acoustic segments through an (N-1)-th one of the acoustic segments.

  17. Streamflow gain/loss in the Republican River basin, Nebraska, March 1989

    USGS Publications Warehouse

    Johnson, Michaela R.; Stanton, Jennifer S.; Cornwall, James F.; Landon, Matthew K.

    2002-01-01

    This arc and point data set contains streamflow measurement sites and reaches indicating streamflow gain or loss under base-flow conditions along the Republican River and tributaries in Nebraska during March 21 to 22, 1989 (Boohar and others, 1990). These measurements were made to obtain data on ground-water/surface-water interaction. Flow was visually observed to be zero, was measured, or was estimated at 136 sites. The measurements were made on the main stem of the Republican River and all flowing tributaries that enter the Republican River above Swanson Reservoir and parts of the Frenchman, Red Willow, and Medicine Creek drainages in the Nebraska part of the Republican River Basin. Tributaries were followed upstream until the first road crossing where zero flow was encountered. For selected streams, points of zero flow upstream of the first zero flow site were also checked. Streamflow gain or loss for each stream reach was calculated by subtracting the streamflow values measured at the upstream end of the reach and values for contributing tributaries from the downstream value. The data obtained reflected base-flow conditions suitable for estimating streamflow gains and losses for stream reaches between sites. This digital data set was created by manually plotting locations of streamflow measurements. These points were used to designate stream-reach segments to calculate gain/loss per river mile. Reach segments were created by manually splitting the lines from a 1:250,000 hydrography data set (Soenksen and others, 1999) at every location where the streams were measured. Each stream-reach segment between streamflow-measurement sites was assigned a unique reach number. All other lines in the hydrography data set without reach numbers were omitted. This data set was created to archive the calculated streamflow gains and losses of selected streams in part of the Republican River Basin, Nebraska in March 1989, and make the data available for use with geographic information systems (GIS). If measurement sites are used separately from reaches, the maximum scale of 1:100,000 should not be exceeded. When used in conjunction with the reach segments, the maximum scale should not exceed 1:250,000.

  18. [Microcirculatory blood and lymph flow examination in eyelid skin by laser Doppler flowmetry].

    PubMed

    Safonova, T N; Kintyukhina, N P; Sidorov, V V; Gladkova, O V; Reyn, E S

    to study normal blood and lymph microcirculation of the upper and lower eyelids in different age groups. The study included 108 volunteers (216 eyes) aged from 20 to 80 years with no signs of changes in anterior segment structures, who were grouped by age ranges (20-30 years, 31-40 years, 41-50 years, 51-60 years, 61-70 years, and 71-80 years) into 6 groups equal in gender and quantitative composition. In all volunteers, microcirculation of the upper and lower eyelids was examined by laser Doppler flowmetry (LDF) ('LASMA MC-1' peripheral blood and lymph flow analyzer and 'LASMA MC' laser diagnostic complex, LASMA LLC). The average perfusion changes in blood and lymph flow as well as blood and lymph flow oscillations were analyzed. Blood and lymph flow in the microvasculature of the upper and lower eyelids is variable and depends on neither the age, nor gender of the test subject. On LDF-gram, every increase in amplitude of blood flow corresponds to a decrease in that of lymph flow. The non-invasive method of LDF expands our diagnostic capabilities as it enables assessment of not only blood, but also lymph flow. The data obtained can serve as a starting point for exploring microcirculation in different age groups in the presence of different pathological processes.

  19. KSC-04pd1478

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, astronaut Tracy Caldwell (left) assists a technician check out the Pump Flow Control Subsystem (PFCS) before it is installed on the upper deck of the S6 Truss. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. The solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  20. KSC-04pd1480

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, astronaut Tracy Caldwell (second from left) assists technicians position the Pump Flow Control Subsystem (PFCS) over the upper deck of the S6 Truss. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  1. KSC-04pd1479

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, a technician steadies the Pump Flow Control Subsystem (PFCS) as it is lifted and moved toward the S6 Truss. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  2. KSC-04pd1481

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, astronaut Tracy Caldwell (second from left) assists technicians lower the Pump Flow Control Subsystem (PFCS) into position onto the upper deck of the S6 Truss. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  3. KSC-04pd1482

    NASA Image and Video Library

    2004-07-15

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, astronaut Tracy Caldwell (left) assists technicians install the Pump Flow Control Subsystem (PFCS) onto the upper deck of the S6 Truss. The PFCS pumps and controls the liquid ammonia used to cool the various Orbital Replacement Units on the Integrated Equipment Assembly that make up the S6 Photo-Voltaic Power Module on the International Space Station (ISS). The fourth starboard truss segment, the S6 Truss measures 112 feet long by 39 feet wide. Its solar arrays are mounted on a “blanket” that can be folded like an accordion for delivery to the ISS. Once in orbit, astronauts will deploy the blankets to their full size. When completed, the Station's electrical power system (EPS) will use eight photovoltaic solar arrays to convert sunlight to electricity. Delivery of the S6 Truss, the last power module truss segment, is targeted for mission STS-119.

  4. Bacterial cell identification in differential interference contrast microscopy images.

    PubMed

    Obara, Boguslaw; Roberts, Mark A J; Armitage, Judith P; Grau, Vicente

    2013-04-23

    Microscopy image segmentation lays the foundation for shape analysis, motion tracking, and classification of biological objects. Despite its importance, automated segmentation remains challenging for several widely used non-fluorescence, interference-based microscopy imaging modalities. For example in differential interference contrast microscopy which plays an important role in modern bacterial cell biology. Therefore, new revolutions in the field require the development of tools, technologies and work-flows to extract and exploit information from interference-based imaging data so as to achieve new fundamental biological insights and understanding. We have developed and evaluated a high-throughput image analysis and processing approach to detect and characterize bacterial cells and chemotaxis proteins. Its performance was evaluated using differential interference contrast and fluorescence microscopy images of Rhodobacter sphaeroides. Results demonstrate that the proposed approach provides a fast and robust method for detection and analysis of spatial relationship between bacterial cells and their chemotaxis proteins.

  5. Surface smoothness: cartilage biomarkers for knee OA beyond the radiologist

    NASA Astrophysics Data System (ADS)

    Tummala, Sudhakar; Dam, Erik B.

    2010-03-01

    Fully automatic imaging biomarkers may allow quantification of patho-physiological processes that a radiologist would not be able to assess reliably. This can introduce new insight but is problematic to validate due to lack of meaningful ground truth expert measurements. Rather than quantification accuracy, such novel markers must therefore be validated against clinically meaningful end-goals such as the ability to allow correct diagnosis. We present a method for automatic cartilage surface smoothness quantification in the knee joint. The quantification is based on a curvature flow method used on tibial and femoral cartilage compartments resulting from an automatic segmentation scheme. These smoothness estimates are validated for their ability to diagnose osteoarthritis and compared to smoothness estimates based on manual expert segmentations and to conventional cartilage volume quantification. We demonstrate that the fully automatic markers eliminate the time required for radiologist annotations, and in addition provide a diagnostic marker superior to the evaluated semi-manual markers.

  6. Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines

    NASA Technical Reports Server (NTRS)

    Ibrahim, Mounir; Danila, Daniel; Simon, Terrence; Mantell, Susan; Sun, Liyong; Gedeon, David; Qiu, Songgang; Wood, Gary; Kelly, Kevin; McLean, Jeffrey

    2010-01-01

    An involute-foil regenerator was designed, microfabricated, and tested in an oscillating-flow test rig. The concept consists of stacked involute-foil nickel disks (see figure) microfabricated via a lithographic process. Test results yielded a performance of about twice that of the 90-percent random-fiber currently used in small Stirling converters. The segmented nature of the involute- foil in both the axial and radial directions increases the strength of the structure relative to wrapped foils. In addition, relative to random-fiber regenerators, the involute-foil has a reduced pressure drop, and is expected to be less susceptible to the release of metal fragments into the working space, thus increasing reliability. The prototype nickel involute-foil regenerator was adequate for testing in an engine with a 650 C hot-end temperature. This is lower than that required by larger engines, and high-temperature alloys are not suited for the lithographic microfabrication approach.

  7. Central Nervous System Infections in Denmark

    ClinicalTrials.gov

    2018-02-04

    Central Nervous System Infections; Bacterial Meningitis; Viral Meningitis; Aseptic Meningitis; Encephalitis; Brain Abscess; Neuroborreliosis; Neurosyphilis; Lyme Disease; Tertiary Syphilis; Cerebral Abscess; Meningitis

  8. Aseptic Meningitis Caused by Lassa Virus: Case Series Report

    PubMed Central

    Bankole, Idowu A.; Iruolagbe, Christopher O.; Muoebonam, Benard E.; Okonofua, Martha O.; Dawodu, Simeon O.; Akpede, George O.

    2016-01-01

    The Lassa virus is known to cause disease in different organ systems of the human body, with varying clinical manifestations. The features of severe clinical disease may include bleeding and/or central nervous system manifestations. Whereas Lassa fever encephalopathy and encephalitis are well described in the literature, there is paucity of data on Lassa virus meningitis. We present the clinical description, laboratory diagnosis, and management of 4 consecutive cases of aseptic meningitis associated with Lassa virus infection without bleeding seen in a region of Nigeria known to be endemic for both the reservoir rodent and Lassa fever. The 4 patients recovered fully following intravenous ribavirin treatment and suffered no neurologic complications. PMID:27957363

  9. Seismic and thermal evidences for subduction of exhumed mantle oceanic crust beneath the seismically quiet Antigua-St Martin Margin segment in the Northern Lesser Antilles

    NASA Astrophysics Data System (ADS)

    Marcaillou, Boris; Klingelhoefer, Frauke; Laurencin, Muriel; Biari, Youssef; Graindorge, David; Lebrun, Jean-Frederic; Laigle, Mireille; Lallemand, Serge

    2017-04-01

    Wide-angle, multichannel reflection seismic data and heat-flow measurements from the Lesser Antilles subduction zone depict a large patch of atypical oceanic basement in the trench and beneath the outer fore-arc offshore of the Antigua-Saint Martin active margin segment. This segment triggers a very low number of earthquakes compared to the seismicity beneath the Virgin Island Platform to the north or in the Central Antilles (Martinique-Guadeloupe) to the south. Seven along-dip and two along-strike multichannel seismic lines acquired in this region show high amplitude steep reflectors that extend downward to 15-km depth in the downgoing slab. These lines also substantiate the absence of any reflections at Moho depth. Based on the wide-angle velocity model, the oceanic basement consists of a 5-km-thick unique layer with p-wave velocities ranging from 5.2 to 7.4 km/s, which is atypical for an oceanic crust. Heat-flow measurements along a transect perpendicular to the margin indicate a "flat" heat-flow trend from the trench to the fore-arc at 40 ± 15 mW.m-2 (Biari et al., same session). This heat flow profile contrasts with the expected trench-to-forearc decreasing heat-flow and the 50% higher heat-flow values measured in the trench offshore off the central Antilles. Calculated heat-flow for an incoming oceanic plate with a depressed geothermal gradient in the trench and heat source at depth in the subduction zone corresponding with temperatures of 200-250°C fit the measurements. We propose that a large patch of exhumed and serpentinized mantle rocks solidified at the slow-spreading mid-Atlantic Ridge is currently subducting beneath the studied margin segment. The fact that the crust here consists of one single layer and comprises velocities higher than found in igneous rocks (> 7.2 km/s) are consistent with this hypothesis. The plate bending possibly triggers long and deep delamination planes that extend into the mantle beneath the serpentinization front, which has been identified as a reflector in the wide-angle seismic data. These delamination planes outcrop at the interplate contact creating weak zones that focus the tectonic deformation in the upper plate. An incoming oceanic crust made of serpentinized mantle rocks is consistent with a depressed geothermal gradient in the trench due to water alteration and heat generation at depth due to serpentinite dehydration. This fluid-rich altered and weak oceanic crust likely reduces the seismic activity along this margin segment.

  10. Metal-on-Metal Hip Retrieval Analysis: A Case Report

    PubMed Central

    Pace, Thomas B.; Rusaw, Kara A.; Minette, Lawrence J.; Shirley, Brayton R.; Snider, Rebecca G.; DesJardins, John D.

    2013-01-01

    This is a case report involving a single case with severe bone and soft tissue destruction in a young male patient with a 10-year-metal on-metal total hip arthroplasty. Following complete aseptic erosion of the affected hip greater trochanter and abductor muscles, the hip was revised for recurrent instability. Histological examination of the patient's periprosthetic tissues, serological studies, and review of recent medical reports of similar cases were used to support an explanation of the destructive process and better contribute to our understanding of human reaction to metal debris in some patients following metal-on-metal hip arthroplasty. PMID:23840999

  11. Complexity of Danger: The Diverse Nature of Damage-associated Molecular Patterns*

    PubMed Central

    Schaefer, Liliana

    2014-01-01

    In reply to internal or external danger stimuli, the body orchestrates an inflammatory response. The endogenous triggers of this process are the damage-associated molecular patterns (DAMPs). DAMPs represent a heterogeneous group of molecules that draw their origin either from inside the various compartments of the cell or from the extracellular space. Following interaction with pattern recognition receptors in cross-talk with various non-immune receptors, DAMPs determine the downstream signaling outcome of septic and aseptic inflammatory responses. In this review, the diverse nature, structural characteristics, and signaling pathways elicited by DAMPs will be critically evaluated. PMID:25391648

  12. Production of a ruminant protein supplement by anaerobic fermentation of feedlot waste filtrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, C.A.; Erdman, M.D.

    1977-01-01

    In studies initiated to develop simple and efficient procedures for the production of feed supplements, it was shown that the filtrate from feedlot wastes diluted with water and filtered could be fermented under anaerobic conditions by mixed rumen bacteria, Lactobacilli, or natural microflora from the feedlot wastes to produce a protein-rich feed supplement. The filtrate is low in carbohydrate and therefore supplemental carbohydrate in the form of whey, molasses, starch from potato processing wastes, or corn starch is necessary. Rigid anaerobic conditions need not be maintained nor must aseptic conditions be observed. (JSR)

  13. Efficient 3D multi-region prostate MRI segmentation using dual optimization.

    PubMed

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    Efficient and accurate extraction of the prostate, in particular its clinically meaningful sub-regions from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, we propose a novel multi-region segmentation approach to simultaneously locating the boundaries of the prostate and its two major sub-regions: the central gland and the peripheral zone. The proposed method utilizes the prior knowledge of the spatial region consistency and employs a customized prostate appearance model to simultaneously segment multiple clinically meaningful regions. We solve the resulted challenging combinatorial optimization problem by means of convex relaxation, for which we introduce a novel spatially continuous flow-maximization model and demonstrate its duality to the investigated convex relaxed optimization problem with the region consistency constraint. Moreover, the proposed continuous max-flow model naturally leads to a new and efficient continuous max-flow based algorithm, which enjoys great advantages in numerics and can be readily implemented on GPUs. Experiments using 15 T2-weighted 3D prostate MR images, by inter- and intra-operator variability, demonstrate the promising performance of the proposed approach.

  14. Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging.

    PubMed

    Bavo, A M; Pouch, A M; Degroote, J; Vierendeels, J; Gorman, J H; Gorman, R C; Segers, P

    2016-09-09

    The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian-Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.

  15. Particle Velocity Measuring System

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Carl, James R. (Inventor)

    1998-01-01

    Method and apparatus are provided for determining the velocity of individual food particles within a liquid/solid food mixture that is cooked by an aseptic cooking method whereby the food mixture is heated as it flows through a flowline. At least one upstream and at least one downstream microwave transducer are provided to determine the minimum possible travel time of the fastest food particle through the flowline. In one embodiment, the upstream detector is not required. In another embodiment, a plurality of small dipole antenna markers are secured to a plurality of food particles to provide a plurality of signals as the markers pass the upstream and downstream transducers. The dipole antenna markers may also include a non-linear element to reradiate a harmonic frequency of a transmitter frequency. Upstream and downstream transducers include dipole antennas that are matched to the impedance of the food slurry and a signal transmission cable by various impedance matching means including unbalanced feed to the antennas.

  16. Axonal transports of tripeptidyl peptidase II in rat sciatic nerves.

    PubMed

    Chikuma, Toshiyuki; Shimizu, Maki; Tsuchiya, Yukihiro; Kato, Takeshi; Hojo, Hiroshi

    2007-01-01

    Axonal transport of tripeptidyl peptidase II, a putative cholecystokinin inactivating serine peptidase, was examined in the proximal, middle, and distal segments of rat sciatic nerves using a double ligation technique. Enzyme activity significantly increased not only in the proximal segment but also in the distal segment 12-72h after ligation, and the maximal enzyme activity was found in the proximal and distal segments at 72h. Western blot analysis of tripeptidyl peptidase II showed that its immunoreactivities in the proximal and distal segments were 3.1- and 1.7-fold higher than that in the middle segment. The immunohistochemical analysis of the segments also showed an increase in immunoreactive tripeptidyl peptidase II level in the proximal and distal segments in comparison with that in the middle segment, indicating that tripeptidyl peptidase II is transported by anterograde and retrograde axonal flow. The results suggest that tripeptidyl peptidase II may be involved in the metabolism of neuropeptides in nerve terminals or synaptic clefts.

  17. Biofilm monitoring coupon system and method of use

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Flanagan, David T. (Inventor)

    1991-01-01

    An apparatus and method is disclosed for biofilm monitoring of a water distribution system which includes the mounting of at least one fitting in a wall port of a manifold in the water distribution system with a passage through the fitting in communication. The insertion of a biofilm sampling member is through the fitting with planar sampling surfaces of different surface treatment provided on linearly arrayed sample coupons of the sampling member disposed in the flow stream in edge-on parallel relation to the direction of the flow stream of the manifold under fluid-tight sealed conditions. The sampling member is adapted to be aseptically removed from or inserted in the fitting and manifold under a positive pressure condition and the fitting passage sealed immediately thereafter by appropriate closure means so as to preclude contamination of the water distribution system through the fitting. The apparatus includes means for clamping the sampling member and for establishing electrical continuity between the sampling surfaces and the system for minimizing electropotential effects. The apparatus may also include a plurality of fittings and sampling members mounted on the manifold to permit extraction of the sampling members in a timed sequence throughout the monitoring period.

  18. Leaf seal for inner and outer casings of a turbine

    DOEpatents

    Schroder, Mark Stewart; Leach, David

    2002-01-01

    A plurality of arcuate, circumferentially extending leaf seal segments form an annular seal spanning between annular sealing surfaces of inner and outer casings of a turbine. The ends of the adjoining seal segments have circumferential gaps to enable circumferential expansion and contraction of the segments. The end of a first segment includes a tab projecting into a recess of a second end of a second segment. Edges of the tab seal against the sealing surfaces of the inner and outer casings have a narrow clearance with opposed edges of the recess. An overlying cover plate spans the joint. Leakage flow is maintained at a minimum because of the reduced gap between the radially spaced edges of the tab and recess, while the seal segments retain the capacity to expand and contract circumferentially.

  19. Quantifying fracture geometry with X-ray tomography: Technique of Iterative Local Thresholding (TILT) for 3D image segmentation

    DOE PAGES

    Deng, Hang; Fitts, Jeffrey P.; Peters, Catherine A.

    2016-02-01

    This paper presents a new method—the Technique of Iterative Local Thresholding (TILT)—for processing 3D X-ray computed tomography (xCT) images for visualization and quantification of rock fractures. The TILT method includes the following advancements. First, custom masks are generated by a fracture-dilation procedure, which significantly amplifies the fracture signal on the intensity histogram used for local thresholding. Second, TILT is particularly well suited for fracture characterization in granular rocks because the multi-scale Hessian fracture (MHF) filter has been incorporated to distinguish fractures from pores in the rock matrix. Third, TILT wraps the thresholding and fracture isolation steps in an optimized iterativemore » routine for binary segmentation, minimizing human intervention and enabling automated processing of large 3D datasets. As an illustrative example, we applied TILT to 3D xCT images of reacted and unreacted fractured limestone cores. Other segmentation methods were also applied to provide insights regarding variability in image processing. The results show that TILT significantly enhanced separability of grayscale intensities, outperformed the other methods in automation, and was successful in isolating fractures from the porous rock matrix. Because the other methods are more likely to misclassify fracture edges as void and/or have limited capacity in distinguishing fractures from pores, those methods estimated larger fracture volumes (up to 80 %), surface areas (up to 60 %), and roughness (up to a factor of 2). In conclusion, these differences in fracture geometry would lead to significant disparities in hydraulic permeability predictions, as determined by 2D flow simulations.« less

  20. BRANCH JUNCTIONS AND THE FLOW OF WATER THROUGH XYLEM IN DOUGLAS-FIR AND PONDEROSA PINE STEMS

    EPA Science Inventory

    Water flowing through the xylem of most plants from the roots to the leaves must pass through junctions where branches have developed from the main stem. These junctions have been studied as both flow constrictions and components of a hydraulic segmentation mechanism to protect ...

  1. Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection.

    PubMed

    Pravadali-Cekic, Sercan; Kocic, Danijela; Hua, Stanley; Jones, Andrew; Dennis, Gary R; Shalliker, R Andrew

    2015-12-15

    Active flow technology (AFT) is new form of column technology that was designed to overcome flow heterogeneity to increase separation performance in terms of efficiency and sensitivity and to enable multiplexed detection. This form of AFT uses a parallel segmented flow (PSF) column. A PSF column outlet end-fitting consists of 2 or 4 ports, which can be multiplexed to connect up to 4 detectors. The PSF column not only allows a platform for multiplexed detection but also the combination of both destructive and non-destructive detectors, without additional dead volume tubing, simultaneously. The amount of flow through each port can also be adjusted through pressure management to suit the requirements of a specific detector(s). To achieve multiplexed detection using a PSF column there are a number of parameters which can be controlled to ensure optimal separation performance and quality of results; that is tube dimensions for each port, choice of port for each type of detector and flow adjustment. This protocol is intended to show how to use and tune a PSF column functioning in a multiplexed mode of detection.

  2. Segmentation of vessels cluttered with cells using a physics based model.

    PubMed

    Schmugge, Stephen J; Keller, Steve; Nguyen, Nhat; Souvenir, Richard; Huynh, Toan; Clemens, Mark; Shin, Min C

    2008-01-01

    Segmentation of vessels in biomedical images is important as it can provide insight into analysis of vascular morphology, topology and is required for kinetic analysis of flow velocity and vessel permeability. Intravital microscopy is a powerful tool as it enables in vivo imaging of both vasculature and circulating cells. However, the analysis of vasculature in those images is difficult due to the presence of cells and their image gradient. In this paper, we provide a novel method of segmenting vessels with a high level of cell related clutter. A set of virtual point pairs ("vessel probes") are moved reacting to forces including Vessel Vector Flow (VVF) and Vessel Boundary Vector Flow (VBVF) forces. Incorporating the cell detection, the VVF force attracts the probes toward the vessel, while the VBVF force attracts the virtual points of the probes to localize the vessel boundary without being distracted by the image features of the cells. The vessel probes are moved according to Newtonian Physics reacting to the net of forces applied on them. We demonstrate the results on a set of five real in vivo images of liver vasculature cluttered by white blood cells. When compared against the ground truth prepared by the technician, the Root Mean Squared Error (RMSE) of segmentation with VVF and VBVF was 55% lower than the method without VVF and VBVF.

  3. Use of an absorbable membrane to position biologically inductive materials in the periprosthetic space of cemented joints.

    PubMed

    DiResta, Gene R; Brown, Holly; Aiken, Sean; Doty, Steven; Schneider, Robert; Wright, Timothy; Healey, John H

    2006-01-01

    A device is presented that positions ultrahigh molecular weight polyethylene (UHMWPE) debris against periprosthetic bone surfaces. This can facilitate the study of aseptic loosening associated with cemented joint prostheses by speeding the appearance of this debris within the periprosthetic space. The device, composed of a 100 microm thick bioabsorbable membrane impregnated with 1.4 x 10(9) sub-micron particles of UHMWPE debris, is positioned on the endosteum of the bone prior to the insertion of the cemented orthopedic implant. An in vitro pullout study and an in vivo canine pilot study were performed to investigate its potential to accelerate "time to aseptic loosening" of cemented prosthetic joints. Pullout studies characterized the influence of the membrane on initial implant fixation. The tensile stresses (mean+/-std.dev.) required to withdraw a prosthesis cemented into canine femurs with and without the membrane were 1.15+/-0.3 and 1.54+/-0.01 MPa, respectively; these findings were not significantly different (p > 0.4). The in vivo pilot study, involving five dogs, was performed to evaluate the efficacy of the debris to accelerate loosening in a canine cemented hip arthroplasty. Aseptic loosening and lameness occurred within 12 months, quicker than the 30 months reported in a retrospective clinical review of canine hip arthroplasty.

  4. Aseptic Culture Systems of Radopholus similis for In Vitro Assays on Musa spp. and Arabidopsis thaliana

    PubMed Central

    Elsen, A.; Lens, K.; Nguyet, D. T. M.; Broos, S.; Stoffelen, R.; De Waele, D.

    2001-01-01

    Radopholus similis is one of the most damaging nematodes in bananas. Chemical control is currently the most-used method, but nematode control through genetic improvement is widely encouraged. The objective of this study was to establish an aseptic culture system for R. similis and determine whether R. similis can infect and reproduce on in vitro banana plantlets and in vitro Arabidopsis thaliana. In the study's first part, a suitable aseptic culture system was developed using alfalfa callus. Radopholus similis could penetrate and reproduce in the callus. Six weeks after inoculation with 25 females, the reproduction ratio was 26.3 and all vermiform stages were present. The reproduction ratio increased to 223.2 after 12 weeks. Results of a greenhouse test showed that R. similis did not lose its pathogenicity after culturing on alfalfa callus. In the study's second part, the infection and reproduction of the nematodes cultured on the callus were studied on both in vitro banana plantlets and A. thaliana. Radopholus similis infected and reproduced on both banana and A. thaliana. Furthermore, nematode damage was observed in the root systems of both hosts. These successful infections open new perspectives for rapid in vitro screening for resistance in banana cultivars and anti-nematode proteins expressed in A. thaliana. PMID:19266012

  5. Microbiological contamination in high and low flow oxygen humidifiers: A systematic review.

    PubMed

    de la Fuente-Sancho, I; Romeu-Bordas, Ó; Fernández-Aedo, I; Vallejo De la Hoz, G; Ballesteros-Peña, S

    2017-12-16

    To determine the risk of microbiological contamination with hospital use high- and low-flow bubbling humidifiers. A systematic literature review was carried out in 6 databases. Observational or experimental studies published between 1990 and 2016 were selected, written in English or Spanish, and in which microbiological contamination with hospital use high- and low-flow bubbling humidifiers was investigated. A total of 12 articles were included: 4 analyzed the water from reusable humidifiers, 4 analyzed the water from prefilled system humidifiers, and the rest compared samples from both models. Microbial contamination was observed in all studies in which reusable humidifiers were evaluated, usually involving common bacteria from the skin flora, while potential pathogenic species were notified in 2 studies. No microbial contamination was isolated from reusable humidifiers, regardless of whether they had been consecutively used over time by a single patient or by several patients. On one hand, there seems to be a low risk of contamination during the first weeks of use of prefilled humidifiers, which allows multiple use in different patients, without a risk of cross-contamination. On the other hand, it should be underscored that handling reusable humidifiers without correct aseptic measures can increase the risk of contamination; replacing reusable humidifiers with prefilled models therefore could be the safest option. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  6. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger's disease.

    PubMed

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Buerger's disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger's disease. In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger's disease is conducted. The geometry of the artery is constructed based on the actual corkscrew artery of a patient diagnosed with the Buerger's disease. The blood properties are the same as the actual blood properties of the patient. The blood flow rate is taken from the available experimental data in the literature. The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered.

  7. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger’s disease

    PubMed Central

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Introduction: Buerger’s disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger’s disease. Methods: In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger’s disease is conducted. The geometry of the artery is constructed based on the actual corkscrew artery of a patient diagnosed with the Buerger’s disease. The blood properties are the same as the actual blood properties of the patient. The blood flow rate is taken from the available experimental data in the literature. Results: The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. Conclusion: It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered. PMID:27340623

  8. Development and Evaluation of a Novel Microemulsion of Dexamethasone and Tobramycin for Topical Ocular Administration.

    PubMed

    Bachu, Rinda Devi; Stepanski, Marina; Alzhrani, Rami M; Jung, Rose; Boddu, Sai H S

    2018-05-01

    The purpose of this study was to develop and evaluate a novel dexamethasone- and tobramycin-loaded microemulsion for its potential for treating anterior segment eye infections. The microemulsion was evaluated for pH, particle size, zeta potential, light transmittance, morphology, and in vitro drug release. Sterility of the microemulsion was evaluated by direct as well as plate inoculation methods. Anti-inflammatory activity of dexamethasone, bactericidal activity of tobramycin, and cytotoxicity of the microemulsion were assessed and compared to that of the marketed eye drop suspension (Tobradex ® ). Histological evaluation was performed in bovine corneas to assess the safety of microemulsion in comparison to Tobradex suspension. In addition, the stability of the microemulsion was studied at 4°C, 25°C, and 40°C. The pH of the microemulsion was close to the pH of tear fluid. The microemulsion displayed an average globule size under 20 nm, with light transmittance around 95%-100%. The aseptically prepared microemulsion remained sterile for up to 14 days. The cytotoxicity of the microemulsion in bovine corneal endothelial cells was comparable to that of the Tobradex suspension. The anti-inflammatory activity of dexamethasone and the antibacterial activity of tobramycin from the microemulsion were significantly higher than those of the Tobradex suspension (P < 0.05). Histological evaluation showed an intact corneal epithelium without any signs of toxicity, and the developed microemulsion was found to be stable at 4°C and 25°C for 3 months. In conclusion, the developed microemulsion could be explored as a suitable alternative to the marketed suspension for treating anterior segment eye infections.

  9. Sympathetic regulation and anterior cingulate cortex volume are altered in a rat model of chronic back pain.

    PubMed

    Touj, Sara; Houle, Sébastien; Ramla, Djamel; Jeffrey-Gauthier, Renaud; Hotta, Harumi; Bronchti, Gilles; Martinoli, Maria-Grazia; Piché, Mathieu

    2017-06-03

    Chronic pain is associated with autonomic disturbance. However, specific effects of chronic back pain on sympathetic regulation remain unknown. Chronic pain is also associated with structural changes in the anterior cingulate cortex (ACC), which may be linked to sympathetic dysregulation. The aim of this study was to determine whether sympathetic regulation and ACC surface and volume are affected in a rat model of chronic back pain, in which complete Freund Adjuvant (CFA) is injected in back muscles. Sympathetic regulation was assessed with renal blood flow (RBF) changes induced by electrical stimulation of a hind paw, while ACC structure was examined by measuring cortical surface and volume. RBF changes and ACC volume were compared between control rats and rats injected with CFA in back muscles segmental (T10) to renal sympathetic innervation or not (T2). In rats with CFA, chronic inflammation was observed in the affected muscles in addition to increased nuclear factor-kappa B (NF-kB) protein expression in corresponding spinal cord segments (p=0.01) as well as decreased ACC volume (p<0.05). In addition, intensity-dependent decreases in RBF during hind paw stimulation were attenuated by chronic pain at T2 (p's<0.05) and T10 (p's<0.05), but less so at T10 compared with T2 (p's<0.05). These results indicate that chronic back pain alters sympathetic functions through non-segmental mechanisms, possibly by altering descending regulatory pathways from ACC. Yet, segmental somato-sympathetic reflexes may compete with non-segmental processes depending on the back region affected by pain and according to the segmental organization of the sympathetic nervous system. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  10. Integrating urban recharge uncertainty into standard groundwater modeling practice: A case study on water main break predictions for the Barton Springs segment of the Edwards Aquifer, Austin, Texas

    NASA Astrophysics Data System (ADS)

    Sinner, K.; Teasley, R. L.

    2016-12-01

    Groundwater models serve as integral tools for understanding flow processes and informing stakeholders and policy makers in management decisions. Historically, these models tended towards a deterministic nature, relying on historical data to predict and inform future decisions based on model outputs. This research works towards developing a stochastic method of modeling recharge inputs from pipe main break predictions in an existing groundwater model, which subsequently generates desired outputs incorporating future uncertainty rather than deterministic data. The case study for this research is the Barton Springs segment of the Edwards Aquifer near Austin, Texas. Researchers and water resource professionals have modeled the Edwards Aquifer for decades due to its high water quality, fragile ecosystem, and stakeholder interest. The original case study and model that this research is built upon was developed as a co-design problem with regional stakeholders and the model outcomes are generated specifically for communication with policy makers and managers. Recently, research in the Barton Springs segment demonstrated a significant contribution of urban, or anthropogenic, recharge to the aquifer, particularly during dry period, using deterministic data sets. Due to social and ecological importance of urban water loss to recharge, this study develops an evaluation method to help predicted pipe breaks and their related recharge contribution within the Barton Springs segment of the Edwards Aquifer. To benefit groundwater management decision processes, the performance measures captured in the model results, such as springflow, head levels, storage, and others, were determined by previous work in elicitation of problem framing to determine stakeholder interests and concerns. The results of the previous deterministic model and the stochastic model are compared to determine gains to stakeholder knowledge through the additional modeling

  11. NURSES INFECTION PREVENTION PRACTICES IN HANDLING INJECTIONS: A CASE OF RIFT VALLEY PROVINCIAL HOSPITAL IN KENYA.

    PubMed

    Chemoiwa, R K; Mukthar, V K; Maranga, A K; Kulei, S J

    2014-10-01

    To analyse the infection prevention practices in handling of injections by nurses in Rift Valley Provincial Hospital in Kenya. A cross-sectional observational study. Rift Valley Provincial hospital which is a level five health facility situated in Nakuru County, Kenya. A sample of 386 injection procedures attributed to the nurses in Rift Valley Provincial Hospital was considered for this study. The study established that among all the injections administered in this study, 43.7% (386) adhered to aseptic techniques. Over seventy five percent (76.9%, n = 386) of the observed injections procedures did not involve the hand-washing, 53.4% (n = 206) did not involve swabbing of a vial rubber cap with alcohol swabs and 95.1%(n = 263) involved using of multidose drug in more than one designated patient. Over ninety five percent (95.6%, n = 364) of the observed procedures involved use of sterile the syringe bit of the devices only while the rest used either clean or contaminated syringes. Around forty percent (42.2%, n = 316) of the injections preparation was done elsewhere (not at the patient bedside) before administration. Slightly over thirty five percent (36.6%, n = 386) of the injections were administered immediately upon reconstitution(at the right time). The study also established the use of aseptic techniques to reconstitute and administer was significantly related to the number of nurses to patients ratio per shift (X2(1) = 3.5: p = 0.04). The findings of this study indicate that patient safety in public hospital is still relatively low. The adherence to basic infection prevention procedures/aseptic techniques in handling of injections by health workers is still a concern. The adherence to aseptic techniques in handling injections is significantly associated with the nurses to patients ratios. Therefore, it is imperative to improve nurse to patient ratio in public health facilities in Kenya.

  12. Growth and toxin production by Clostridium botulinum in steamed rice aseptically packed under modified atmosphere.

    PubMed

    Kasai, Yoshiaki; Kimura, Bon; Kawasaki, Susumu; Fukaya, Tetsuya; Sakuma, Kinya; Fujii, Tateo

    2005-05-01

    Sales and consumption of ready-to-eat aseptic steamed rice products have increased manyfold in Japan over the past 10 years. To determine the safety of steamed rice (water content 60%, pH 6.5) aseptically packaged under modified atmosphere, challenge studies were performed using a mixture of Clostridium botulinum proteolytic strains (five strains of type A and five strains of type B). Atmospheric conditions of 0 and 15% oxygen (with 5% CO2 and 5% N2 as the balance) were used. No neurotoxins were detected, and organoleptically acceptable conditions persisted for 24 weeks at 15% oxygen conditions. However, botulinum neurotoxin was found in one of three samples at 12 weeks and in one of two samples at 24 weeks at 0% oxygen and 30 degrees C. When samples were inoculated with C. botulinum with amylase (0% oxygen), neurotoxin and sample spoilage was detected after only 1 week of storage. Challenge studies using proteolytic strains of C. botulinum mixed with Bacillus subtilis (amylase formers) also were performed with atmosphere conditions of oxygen at 0, 5, 10, and 15% (with 5% CO2 and 5% N2 as the balance). Under 10 and 15% oxygen conditions, neurotoxin was not detected after 1 week of storage, but sample spoilage was detected after the same period. Under 0% oxygen conditions, neurotoxin was detected at 1 week, but the sample remained organoleptically acceptable even after 2 weeks of storage. Both neurotoxin and sample spoilage were detected at 1 week of storage under 5% oxygen conditions. Based on these results, cocontamination of amylase-producing Bacillus with C. botulinum would increase the risk of foodborne botulism when aseptic rice samples are packed under low-oxygen conditions (<5%). Therefore, to ensure the safety of these products, packing under atmospheric containing more than 10% oxygen is recommended.

  13. Auditing Safety of Compounding and Reconstituting of Intravenous Medicines on Hospital Wards in Finland.

    PubMed

    Suvikas-Peltonen, Eeva; Palmgren, Joni; Häggman, Verner; Celikkayalar, Ercan; Manninen, Raija; Airaksinen, Marja

    2017-01-01

    On the hospital wards in Finland, nurses generally reconstitute intravenous medicines, such as antibiotics, analgesics, and antiemetics prescribed by doctors. Medicine reconstitution is prone to many errors. Therefore, it is important to identify incorrect practices in the reconstitution of medicine to improve patient safety in hospitals. The aim of this study was to audit the compounding and reconstituting of intravenous medicines on hospital wards in a secondary-care hospital in Finland by using an assessment tool and microbiological testing for identifying issues posing patient safety risks. A hospital pharmacist conducted an external audit by using a validated 65-item assessment tool for safe-medicine compounding practices on 20 wards of the selected hospital. Also, three different microbiological samples were collected to assure the aseptics. Practices were evaluated using a four-point rating scale of "never performed," "rarely performed," "often performed," and "always performed," and were based on observation and interviews with nurses or ward pharmacists. In addition, glove-, settle plate-, and media fill-tests were collected. Associations between microbial sample results and audit-tool results were discussed. Altogether, only six out of the 65 items were fully implemented in all wards; these were related to logistic practices and quality assurance. More than half of the wards used incorrect practices ("rarely performed" or "never performed") for five items. Most of these obviated practices related to aseptic practices. All media-fill tests were clean but the number of colony forming units in glove samples and settle- plate samples varied from 0 to >100. More contamination was found in wards where environmental conditions were inadequate or the use of gloves was incorrect. Compounding practices were [mostly] quite well adapted, but the aseptic practices needed improvement. Attention should have been directed particularly to good aseptic techniques and compounding environment on the wards. These results can be used for updating the guidelines and for training nurses involved in compounding. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  14. Raised Proinflammatory Cytokine Production Within Cerebrospinal Fluid Precedes Fever Onset in Patients With Neurosurgery-Associated Bacterial Meningitis.

    PubMed

    Liu, Zhuo-Hao; Tu, Po-Hsun; Chen, Nan-Yu; Yip, Ping K; Bowes, Amy L; Lee, Cheng-Chi; Chan, She-Hung; Kung, Chua-Chi; Wang, Alvin Yi-Chou; Wu, Chieh-Tsai; Lee, Shih-Tseng

    2015-11-01

    The objective of the present study was to determine whether selective inflammatory cytokine concentrations within cerebrospinal fluid are useful markers for the differential diagnosis of aseptic and bacterial meningitis within neurosurgical patients. Prospective, open-label, observational, cohort study. Neurosurgical ICU, Chang Gung Memorial Hospital. Thirty-two consecutive neurosurgical patients who had postoperative fever following external ventricular drain insertion for the treatment of brain injury underwent serial cerebrospinal fluid cytokine analysis pre and post fever to determine the value of such markers in ascertaining the differential diagnosis of meningitis. Cerebrospinal fluid samples were collected on the day of fever onset, as well as on day 2 and 4 pre and post fever development. Tumor necrosis factor-α, interleukin-1β, interleukin-6, interleukin-8, transforming growth factor-β, and procalcitonin were subsequently analyzed using enzyme-linked immunosorbent assay analysis techniques. Inflammatory marker levels were compared among febrile aseptic, bacterial, and nonmeningitis patients to determine cerebrospinal fluid inflammatory changes over time. Significant increases in cerebrospinal fluid tumor necrosis factor -α, interleukin-1β, interleukin-6, and interleukin-8 levels were observed within patients with bacterial meningitis at fever onset, which was not evident in aseptic or nonmeningitis patients. Furthermore, significant increases in cerebrospinal fluid tumor necrosis factor-α, interleukin-1β, interleukin-6, and interleukin-8 levels were detected as early as 4 days prior to fever onset within patients with bacterial meningitis when compared with both aseptic and nonmeningitis groups. Interestingly, procalcitonin was only significantly increased in patients with bacterial meningitis on the fourth day post fever. The present study suggests that raised cerebrospinal fluid tumor necrosis factor -α, interleukin-1β, and interleukin-8 in a temporal manner may indicate early bacterial meningitis development in neurosurgical patients, enabling earlier diagnostic certainty and improved patient outcomes.

  15. Aseptic meningitis in children--the Singapore experience.

    PubMed

    Tee, W S N; Choong, C T; Lin, R V T P; Ling, A E

    2002-11-01

    To study the incidence, aetiology, clinical characteristics and management of paediatric aseptic meningitis in a paediatric hospital in Singapore. Patients with cerebrospinal fluid (CSF) pleocytosis, a negative Gram stain and bacterial culture were reviewed retrospectively from 1 January to 31 December 2000. Eighty-seven patients who fulfilled the criteria for aseptic meningitis and without neurological deficits were studied. In addition, reverse transcriptase polymerase chain reaction (RT-PCR) using pan enterovirus primers was subsequently performed on 73 of these CSF specimens which were available for storage. The incidence of aseptic meningitis was approximately 37 cases per 10,000 admissions. Non-polio enteroviruses were isolated from 29 of 64 (45.3%) CSF and 38 of 52 (73.1%) stool samples. RT-PCR was positive in 43 (58.9%) of the archived CSF specimens. The aetiologies of the remaining cases were mostly unidentified. Their ages ranged from 5 days to 12 years (median, 2 months). All patients except 1 had fever. Vomiting or poor feeding occurred in 44.7%, cough or running nose in 35.3%, irritability was observed in 35.3%, seizures in 7.1%, a rash in 10.6% and diarrhoea in 5.9%. All patients recovered without sequelae. The median CSF white cell count was 212 cells/mm3 (range, 7 to 12,000). The median glucose concentration was 2.7 mmol/L (range, 1.6 to 4.4). The median CSF/blood glucose ratio was 0.52 (range, 0.23 to 0.73). Median length of stay was 7 days (range, 4 to 17). Eighty-four patients (96.6%) received antibiotics for a median of 5.5 days (range, 2 to 14). Enteroviruses were the most common aetiologic agent identified. A method of early diagnosis using RT-PCR for enteroviruses is necessary to reduce the current duration of antibiotic usage and to decrease the length of hospital stay.

  16. Automatic tracking of labeled red blood cells in microchannels.

    PubMed

    Pinho, Diana; Lima, Rui; Pereira, Ana I; Gayubo, Fernando

    2013-09-01

    The current study proposes an automatic method for the segmentation and tracking of red blood cells flowing through a 100- μm glass capillary. The original images were obtained by means of a confocal system and then processed in MATLAB using the Image Processing Toolbox. The measurements obtained with the proposed automatic method were compared with the results determined by a manual tracking method. The comparison was performed by using both linear regressions and Bland-Altman analysis. The results have shown a good agreement between the two methods. Therefore, the proposed automatic method is a powerful way to provide rapid and accurate measurements for in vitro blood experiments in microchannels. Copyright © 2012 John Wiley & Sons, Ltd.

  17. [The treatment of suppurative and atonic wounds with the CO2 laser and the helium-neon laser].

    PubMed

    Poleganova, I U; Iarŭmov, N; Popadiĭn, N

    1991-01-01

    The doctrine on wounds is the most important and current one in general surgery and reflects the level and development of medicine. Each surgeon should be well acquainted with all processes and stages of wound healing, because treatment of a suppurative wound requires keen knowledge and art. The basic principle of the local treatment of a septic wound is the thorough knowledge on the objective criteria underlying the course of the wound process and on the etiopathogenetic therapy. Laser therapy of wounds accomplishes adequate necrotomy, acts aseptically on the wound surfaces, inhibits the wound microbial flora and stimulates the regeneration processes. The authors record their experience in CO2 laser and helium-neon treatment of 120 patients with suppurative, atonic and decubital wounds over the period 1984-1990.

  18. HPC enabled real-time remote processing of laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Ronaghi, Zahra; Sapra, Karan; Izard, Ryan; Duffy, Edward; Smith, Melissa C.; Wang, Kuang-Ching; Kwartowitz, David M.

    2016-03-01

    Laparoscopic surgery is a minimally invasive surgical technique. The benefit of small incisions has a disadvantage of limited visualization of subsurface tissues. Image-guided surgery (IGS) uses pre-operative and intra-operative images to map subsurface structures. One particular laparoscopic system is the daVinci-si robotic surgical system. The video streams generate approximately 360 megabytes of data per second. Real-time processing this large stream of data on a bedside PC, single or dual node setup, has become challenging and a high-performance computing (HPC) environment may not always be available at the point of care. To process this data on remote HPC clusters at the typical 30 frames per second rate, it is required that each 11.9 MB video frame be processed by a server and returned within 1/30th of a second. We have implement and compared performance of compression, segmentation and registration algorithms on Clemson's Palmetto supercomputer using dual NVIDIA K40 GPUs per node. Our computing framework will also enable reliability using replication of computation. We will securely transfer the files to remote HPC clusters utilizing an OpenFlow-based network service, Steroid OpenFlow Service (SOS) that can increase performance of large data transfers over long-distance and high bandwidth networks. As a result, utilizing high-speed OpenFlow- based network to access computing clusters with GPUs will improve surgical procedures by providing real-time medical image processing and laparoscopic data.

  19. Effective Marketing Strategies Flow from Sound Segmentation Data.

    ERIC Educational Resources Information Center

    Chen, Henry C. K.; And Others

    The paper investigates the potential market segments of an upper division university in transition to 4-year status, and explores selection criteria and the influence of various information sources on the choice of university by the potential target students. Data sources for the study included a survey of 142 freshmen students of whom 120…

  20. Thermal-Interaction Matrix For Resistive Test Structure

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G.; Dhiman, Jaipal K.; Zamani, Nasser

    1990-01-01

    Linear mathematical model predicts increase in temperature in each segment of 15-segment resistive structure used to test electromigration. Assumption of linearity based on fact: equations that govern flow of heat are linear and coefficients in equations (heat conductivities and capacities) depend only weakly on temperature and considered constant over limited range of temperature.

  1. Extraction of Capillary Non-perfusion from Fundus Fluorescein Angiogram

    NASA Astrophysics Data System (ADS)

    Sivaswamy, Jayanthi; Agarwal, Amit; Chawla, Mayank; Rani, Alka; Das, Taraprasad

    Capillary Non-Perfusion (CNP) is a condition in diabetic retinopathy where blood ceases to flow to certain parts of the retina, potentially leading to blindness. This paper presents a solution for automatically detecting and segmenting CNP regions from fundus fluorescein angiograms (FFAs). CNPs are modelled as valleys, and a novel technique based on extrema pyramid is presented for trough-based valley detection. The obtained valley points are used to segment the desired CNP regions by employing a variance-based region growing scheme. The proposed algorithm has been tested on 40 images and validated against expert-marked ground truth. In this paper, we present results of testing and validation of our algorithm against ground truth and compare the segmentation performance against two others methods.The performance of the proposed algorithm is presented as a receiver operating characteristic (ROC) curve. The area under this curve is 0.842 and the distance of ROC from the ideal point (0,1) is 0.31. The proposed method for CNP segmentation was found to outperform the watershed [1] and heat-flow [2] based methods.

  2. The ecological limits of hydrologic alteration (ELOHA): A new framework for developing regional environmental flow standards

    USGS Publications Warehouse

    Poff, N.L.; Richter, B.D.; Arthington, A.H.; Bunn, S.E.; Naiman, R.J.; Kendy, E.; Acreman, M.; Apse, C.; Bledsoe, B.P.; Freeman, Mary C.; Henriksen, J.; Jacobson, R.B.; Kennen, J.G.; Merritt, D.M.; O'Keeffe, J. H.; Olden, J.D.; Rogers, K.; Tharme, R.E.; Warner, A.

    2010-01-01

    The flow regime is a primary determinant of the structure and function of aquatic and riparian ecosystems for streams and rivers. Hydrologic alteration has impaired riverine ecosystems on a global scale, and the pace and intensity of human development greatly exceeds the ability of scientists to assess the effects on a river-by-river basis. Current scientific understanding of hydrologic controls on riverine ecosystems and experience gained from individual river studies support development of environmental flow standards at the regional scale. 2. This paper presents a consensus view from a group of international scientists on a new framework for assessing environmental flow needs for many streams and rivers simultaneously to foster development and implementation of environmental flow standards at the regional scale. This framework, the ecological limits of hydrologic alteration (ELOHA), is a synthesis of a number of existing hydrologic techniques and environmental flow methods that are currently being used to various degrees and that can support comprehensive regional flow management. The flexible approach allows scientists, water-resource managers and stakeholders to analyse and synthesise available scientific information into ecologically based and socially acceptable goals and standards for management of environmental flows. 3. The ELOHA framework includes the synthesis of existing hydrologic and ecological databases from many rivers within a user-defined region to develop scientifically defensible and empirically testable relationships between flow alteration and ecological responses. These relationships serve as the basis for the societally driven process of developing regional flow standards. This is to be achieved by first using hydrologic modelling to build a 'hydrologic foundation' of baseline and current hydrographs for stream and river segments throughout the region. Second, using a set of ecologically relevant flow variables, river segments within the region are classified into a few distinctive flow regime types that are expected to have different ecological characteristics. These river types can be further subclassified according to important geomorphic features that define hydraulic habitat features. Third, the deviation of current-condition flows from baseline-condition flow is determined. Fourth, flow alteration-ecological response relationships are developed for each river type, based on a combination of existing hydroecological literature, expert knowledge and field studies across gradients of hydrologic alteration. 4. Scientific uncertainty will exist in the flow alteration-ecological response relationships, in part because of the confounding of hydrologic alteration with other important environmental determinants of river ecosystem condition (e.g. temperature). Application of the ELOHA framework should therefore occur in a consensus context where stakeholders and decision-makers explicitly evaluate acceptable risk as a balance between the perceived value of the ecological goals, the economic costs involved and the scientific uncertainties in functional relationships between ecological responses and flow alteration. 5. The ELOHA framework also should proceed in an adaptive management context, where collection of monitoring data or targeted field sampling data allows for testing of the proposed flow alteration-ecological response relationships. This empirical validation process allows for a fine-tuning of environmental flow management targets. The ELOHA framework can be used both to guide basic research in hydroecology and to further implementation of more comprehensive environmental flow management of freshwater sustainability on a global scale. ?? 2009 Blackwell Publishing Ltd.

  3. NASA Space Safety Standards and Procedures for Human Rating Requirements

    NASA Technical Reports Server (NTRS)

    Shivers, C. Herbert

    2009-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA) has arguably led this planet in space exploration and certainly has been one of two major leaders in those endeavors. NASA governance is institutionalized and managed in a series documents arranged in a hierarchy and flowing down to the work levels. A document tree of NASA s documentation in its totality would likely overwhelm and not be very informative. Taken in segments related to the various business topics and focusing in those segments, however, provides a logical and understandable relationship and flow of requirements and processes. That is the nature of this chapter, a selection of NASA documentation pertaining to space exploration and a description of how those documents together form the plan by which NASA business for space exploration is conducted. Information presented herein is taken from NASA publications and is available publicly and no information herein is protected by copyright or security regulations. While NASA documents are the source of information presented herein, any and all views expressed herein and any misrepresentations of NASA data that may occur herein are those of the author and should not be considered NASA official positions or statements, nor should NASA endorsement of anything presented in this work be assumed.

  4. Do Chinese Readers Follow the National Standard Rules for Word Segmentation during Reading?

    PubMed Central

    Liu, Ping-Ping; Li, Wei-Jun; Lin, Nan; Li, Xing-Shan

    2013-01-01

    We conducted a preliminary study to examine whether Chinese readers’ spontaneous word segmentation processing is consistent with the national standard rules of word segmentation based on the Contemporary Chinese language word segmentation specification for information processing (CCLWSSIP). Participants were asked to segment Chinese sentences into individual words according to their prior knowledge of words. The results showed that Chinese readers did not follow the segmentation rules of the CCLWSSIP, and their word segmentation processing was influenced by the syntactic categories of consecutive words. In many cases, the participants did not consider the auxiliary words, adverbs, adjectives, nouns, verbs, numerals and quantifiers as single word units. Generally, Chinese readers tended to combine function words with content words to form single word units, indicating they were inclined to chunk single words into large information units during word segmentation. Additionally, the “overextension of monosyllable words” hypothesis was tested and it might need to be corrected to some degree, implying that word length have an implicit influence on Chinese readers’ segmentation processing. Implications of these results for models of word recognition and eye movement control are discussed. PMID:23408981

  5. Analysis of interactions between channel dynamics and vegetation development following damming: example of the Old Rhine downstream of Kembs (1949-2009)

    NASA Astrophysics Data System (ADS)

    Arnaud, F.; Béraud, C.; Piégay, H.; Schmitt, L.; Rollet, A.; Johnstone, K.; Hoenen, D.; Béal, D.

    2010-12-01

    The 45 km-long reach of the Rhine River from Kembs to Breisach has been heavily impacted by engineering works during the last two centuries. The Kembs dam and the lateral “Grand Canal d’Alsace” achieved in 1959 induced significant decrease in sediment transport and diversion of most of the flow in the lateral canal so that the by-passed “Old Rhine” runs now a minimum flow (3% of the mean annual discharge during 300 days per year). Two combined approaches were performed to understand the Old Rhine morphological response to “dewatering”, peak flow reduction and sediment transport disruption in particular the vegetation expansion process and its potential feedback impacts on the channel hydraulics and the sediment transport: i) a space-time approach using series of aerial photographs and historical cross-sections and ii) 1D morphodynamic simulations. Sets of aerial photographs integrated in a GIS environment have been used to map the extent of water bodies, gravel bars, riparian vegetation (grasslands, shrubs, trees identified using differences in colour, texture and structure) and anthropogenic features every 10 years since the 1950s. Results show a strong channel narrowing and associated vegetation expansion until 1982. Tests conducted on the different dates underlined homogeneous segments and downstream progression of the processes through time, demonstrating different patterns of adjustments. Cross-sections of 1950 and 1990 were overlaid with land cover layers, demonstrating that incision and sedimentation areas are spatially linked with the planform changes. From these findings, we hypothesised that vegetation encroachment modified hydraulic conditions, enabling sediment transport, winnowing and deposition processes despite of peak flow reduction and armour layer development due to intense incision following channelization works. In order to test these causality hypothesis, the mean sediment mobility along the homogeneous segments was assessed using 1D hydromorphodynamical simulations. Indeed, numerical modelling is able to calculate the bed shear stress over the critical shear stress ratio for different grain sizes according to the type of vegetation observed and the magnitude and duration of floods occurred. Finally, both GIS study and 1D modelling are complementary revealing the channel and vegetation evolution and underlined the significant impact of vegetation development on the bed dynamics over decades.

  6. Molecular Age-Related Changes in the Anterior Segment of the Eye.

    PubMed

    Hernandez-Zimbron, Luis Fernando; Gulias-Cañizo, Rosario; Golzarri, María F; Martínez-Báez, Blanca Elizabeth; Quiroz-Mercado, Hugo; Gonzalez-Salinas, Roberto

    2017-01-01

    To examine the current knowledge about the age-related processes in the anterior segment of the eye at a biological, clinical, and molecular level. We reviewed the available published literature that addresses the aging process of the anterior segment of the eye and its associated molecular and physiological events. We performed a search on PubMed, CINAHL, and Embase using the MeSH terms "eye," "anterior segment," and "age." We generated searches to account for synonyms of these keywords and MESH headings as follows: (1) "Eye" AND "ageing process" OR "anterior segment ageing" and (2) "Anterior segment" AND "ageing process" OR "anterior segment" AND "molecular changes" AND "age." Results . Among the principal causes of age-dependent alterations in the anterior segment of the eye, we found the mutation of the TGF- β gene and loss of autophagy in addition to oxidative stress, which contributes to the pathogenesis of degenerative diseases. In this review, we summarize the current knowledge regarding some of the molecular mechanisms related to aging in the anterior segment of the eye. We also introduce and propose potential roles of autophagy, an important mechanism responsible for maintaining homeostasis and proteostasis under stress conditions in the anterior segment during aging.

  7. Automated analysis of Physarum network structure and dynamics

    NASA Astrophysics Data System (ADS)

    Fricker, Mark D.; Akita, Dai; Heaton, Luke LM; Jones, Nick; Obara, Boguslaw; Nakagaki, Toshiyuki

    2017-06-01

    We evaluate different ridge-enhancement and segmentation methods to automatically extract the network architecture from time-series of Physarum plasmodia withdrawing from an arena via a single exit. Whilst all methods gave reasonable results, judged by precision-recall analysis against a ground-truth skeleton, the mean phase angle (Feature Type) from intensity-independent, phase-congruency edge enhancement and watershed segmentation was the most robust to variation in threshold parameters. The resultant single pixel-wide segmented skeleton was converted to a graph representation as a set of weighted adjacency matrices containing the physical dimensions of each vein, and the inter-vein regions. We encapsulate the complete image processing and network analysis pipeline in a downloadable software package, and provide an extensive set of metrics that characterise the network structure, including hierarchical loop decomposition to analyse the nested structure of the developing network. In addition, the change in volume for each vein and intervening plasmodial sheet was used to predict the net flow across the network. The scaling relationships between predicted current, speed and shear force with vein radius were consistent with predictions from Murray’s law. This work was presented at PhysNet 2015.

  8. Aseptic Freeze-Dried versus Sterile Wet-Packaged Human Cadaveric Acellular Dermal Matrix in Immediate Tissue Expander Breast Reconstruction: A Propensity Score Analysis.

    PubMed

    Hanson, Summer E; Meaike, Jesse D; Selber, Jesse C; Liu, Jun; Li, Liang; Hassid, Victor J; Baumann, Donald P; Butler, Charles E; Garvey, Patrick B

    2018-05-01

    Although multiple acellular dermal matrix sources exist, it is unclear how its processing impacts complication rates. The authors compared complications between two preparations of human cadaveric acellular dermal matrix (freeze dried and ready-to-use) in immediate tissue expander breast reconstruction to analyze the effect of processing on complications. The authors retrospectively reviewed all alloplastic breast reconstructions with freeze-dried or ready-to-use human acellular dermal matrices between 2006 and 2016. The primary outcome measure was surgical-site occurrence defined as seroma, skin dehiscence, surgical-site infection, or reconstruction failure. The two groups were compared before and after propensity score matching. The authors included 988 reconstructions (freeze-dried, 53.8 percent; ready-to-use, 46.2 percent). Analysis of 384 propensity score-matched pairs demonstrated a slightly higher rate of surgical-site occurrence (21.4 percent versus 16.7 percent; p = 0.10) and surgical-site infection (9.6 percent versus 7.8 percent; p = 0.13) in the freeze-dried group than in the ready-to-use group, but the difference was not significant. However, failure was significantly higher for the freeze-dried versus ready-to-use group (7.8 percent versus 4.4 percent; p = 0.050). This is the largest study comparing the outcomes of alloplastic breast reconstruction using human acellular dermal matrix materials prepared by different methods. The authors demonstrated higher early complications with aseptic, freeze-dried matrix than with sterile ready-to-use matrix; reconstructive failure was the only outcome to achieve statistical significance. The authors conclude that acellular dermal matrix preparation has an independent impact on patient outcomes in their comparison of one company's product. Therapeutic, III.

  9. Hypersensitivity reactions to metal implants: laboratory options.

    PubMed

    Carossino, Anna Maria; Carulli, Christian; Ciuffi, Simone; Carossino, Roberto; Zappoli Thyrion, Giorgia Donata; Zonefrati, Roberto; Innocenti, Massimo; Brandi, Maria Luisa

    2016-11-23

    All implant compounds undergo an electrochemical process when in contact with biological fluids, as well as mechanical corrosion due to abrasive wear, with production of metal debris that may inhibit repair processes. None of the commonly-used methods can diagnose implant allergies when used singly, therefore a panel of tests should be performed on allergic patients as pre-operative screening, or when a postoperative metal sensitisation is suspected. We analysed patients with painful prostheses and subjects prone to allergies using the Patch Test in comparison with the Lymphocyte Transformation Test. Cytokine production was evaluated to identify prognostic markers for early diagnosis of aseptic loosening. Metal debris endocytosis and cytoskeletal rearrangement was visualised by confocal microscopy. Our results demonstrate that the Lymphocyte Transformation Test can identify patients who have a predisposition to develop allergic reactions and can confirm the diagnosis of hypersensitivity in patients with painful prostheses. The prevalence of a Th2-cytokine pattern may be used to identify predisposition to the development of allergic diseases, while the selective presence of osteoclastogenic cytokines may be used as predictor of a negative outcome in patients with painful prosthesis. The hypothesis of the prognostic value of these cytokines as early markers of aseptic loosening is attractive, but its confirmation would require extensive testing. The Lymphocyte Transformation Test is the most suitable method for testing systemic allergies. We suggest that the combined use of the Patch Test and the Lymphocyte Transformation Test, associated with cytokine detection in selected patients, could provide a useful tool for preventive evaluation of immune reactivity in patients undergoing primary joint replacement surgery, and for clinical monitoring of the possible onset of a metal sensitization in patients with implanted devices.

  10. Computer-aided liver volumetry: performance of a fully-automated, prototype post-processing solution for whole-organ and lobar segmentation based on MDCT imaging.

    PubMed

    Fananapazir, Ghaneh; Bashir, Mustafa R; Marin, Daniele; Boll, Daniel T

    2015-06-01

    To evaluate the performance of a prototype, fully-automated post-processing solution for whole-liver and lobar segmentation based on MDCT datasets. A polymer liver phantom was used to assess accuracy of post-processing applications comparing phantom volumes determined via Archimedes' principle with MDCT segmented datasets. For the IRB-approved, HIPAA-compliant study, 25 patients were enrolled. Volumetry performance compared the manual approach with the automated prototype, assessing intraobserver variability, and interclass correlation for whole-organ and lobar segmentation using ANOVA comparison. Fidelity of segmentation was evaluated qualitatively. Phantom volume was 1581.0 ± 44.7 mL, manually segmented datasets estimated 1628.0 ± 47.8 mL, representing a mean overestimation of 3.0%, automatically segmented datasets estimated 1601.9 ± 0 mL, representing a mean overestimation of 1.3%. Whole-liver and segmental volumetry demonstrated no significant intraobserver variability for neither manual nor automated measurements. For whole-liver volumetry, automated measurement repetitions resulted in identical values; reproducible whole-organ volumetry was also achieved with manual segmentation, p(ANOVA) 0.98. For lobar volumetry, automated segmentation improved reproducibility over manual approach, without significant measurement differences for either methodology, p(ANOVA) 0.95-0.99. Whole-organ and lobar segmentation results from manual and automated segmentation showed no significant differences, p(ANOVA) 0.96-1.00. Assessment of segmentation fidelity found that segments I-IV/VI showed greater segmentation inaccuracies compared to the remaining right hepatic lobe segments. Automated whole-liver segmentation showed non-inferiority of fully-automated whole-liver segmentation compared to manual approaches with improved reproducibility and post-processing duration; automated dual-seed lobar segmentation showed slight tendencies for underestimating the right hepatic lobe volume and greater variability in edge detection for the left hepatic lobe compared to manual segmentation.

  11. Repeatability of Non–Contrast-Enhanced Lower-Extremity Angiography Using the Flow-Spoiled Fresh Blood Imaging

    PubMed Central

    Zhang, Yuyang; Xing, Zhen; She, Dejun; Huang, Nan; Cao, Dairong

    2018-01-01

    Purpose The aim of this study was to prospectively evaluate the repeatability of non–contrast-enhanced lower-extremity magnetic resonance angiography using the flow-spoiled fresh blood imaging (FS-FBI). Methods Forty-three healthy volunteers and 15 patients with lower-extremity arterial stenosis were recruited in this study and were examined by FS-FBI. Digital subtraction angiography was performed within a week after the FS-FBI in the patient group. Repeatability was assessed by the following parameters: grading of image quality, diameter and area of major arteries, and grading of stenosis of lower-extremity arteries. Two experienced radiologists blinded for patient data independently evaluated the FS-FBI and digital subtraction angiography images. Intraclass correlation coefficients (ICCs), sensitivity, and specificity were used for statistical analysis. Results The grading of image quality of most data was satisfactory. The ICCs for the first and second measures were 0.792 and 0.884 in the femoral segment and 0.803 and 0.796 in the tibiofibular segment for healthy volunteer group, 0.873 and 1.000 in the femoral segment, and 0.737 and 0.737 in the tibiofibular segment for the patient group. Intraobserver and interobserver agreements on diameter and area of arteries were excellent, with ICCs mostly greater than 0.75 in the volunteer group. For stenosis grading analysis, intraobserver ICCs range from 0.784 to 0.862 and from 0.778 to 0.854, respectively. Flow-spoiled fresh blood imaging yielded a mean sensitivity and specificity to detect arterial stenosis or occlusion of 90% and 80% for femoral segment and 86.7% and 93.3% for tibiofibular segment at least. Conclusions Lower-extremity angiography with FS-FBI is a reliable and reproducible screening tool for lower-extremity atherosclerotic disease, especially for patients with impaired renal function. PMID:28787351

  12. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 p<1e-05). No significant difference was measured between 120 kVp and 70 keV mean TFR values on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; p<1e-04). At 70 keV, BH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  13. Spring contributions to water quality and nitrate loads in the Suwannee River during base flow in July 1995

    USGS Publications Warehouse

    Pittman, J.R.; Hatzell, H.H.; Oaksford, E.T.

    1997-01-01

    The Suwannee River flows through an area of north-central Florida where ground water has elevated nitrate concentrations. A study was conducted to determine how springs and other ground-water inflow affect the quantity and quality of water in the Suwannee River. The study was done on a 33-mile (mi) reach of the lower Suwannee River from just downstream of Dowling Park, Fla., to Branford, Fla. Water samples for nitrate concentrations (dissolved nitrite plus nitrate as nitrogen) and discharge data were collected at 11 springs and 3 river sites during the 3-day period in July 1995 during base flow in the river. In the study reach, all inflow to the river is derived from ground water. Measured springs and other ground-water inflow, such as unmeasured springs and upward diffuse leakage through the riverbed, increased the river discharge 47 percent over the 33-mi reach. The 11 measured springs contributed 41 percent of the increased discharge and other ground-water inflow contributed the remaining 59 percent. River nitrate loads increased downstream from 2,300 to 6,000 kilograms per day (kg/d), an increase of 160 percent in the 33-mi study reach. Measured springs contributed 46 percent of this increase and other ground-water inflow contributed the remaining 54 percent. The study reach was divided at Luraville, Fla., into an 11-mi upper segment and a 22-mi lower segment to determine whether the ground-water inflows and nitrate concentrations were uniform throughout the entire study reach (fig. 1). The two segments were dissimilar. The amount of water added to the river by measured springs more than tripled from the upper to the lower segment. Even though the median nitrate concentration for the three springs in the upper segment (1.7 milligrams per liter (mg/L)) was similar to the median for the eight springs in the lower segment (1.8 mg/L), nitrate concentrations in the river almost doubled from 0.46 to 0.83 mg/L in the lower segment. Only 11 percent of the increase in nitrate load for the study reach occurred in the upper segment; the remaining 89 percent occurred in the lower segment. Measured springs were the major source of nitrate load in the upper reach and other ground-water inflow was the major source in the lower segment. Differences in nitrate loads between the upper and lower river segments are probably controlled by such factors as differences in the magnitude of the spring discharges, the size and location of spring basins, and the hydrologic characteristics of ground water in the study area.

  14. Fast globally optimal segmentation of 3D prostate MRI with axial symmetry prior.

    PubMed

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    We propose a novel global optimization approach to segmenting a given 3D prostate T2w magnetic resonance (MR) image, which enforces the inherent axial symmetry of the prostate shape and simultaneously performs a sequence of 2D axial slice-wise segmentations with a global 3D coherence prior. We show that the proposed challenging combinatorial optimization problem can be solved globally and exactly by means of convex relaxation. With this regard, we introduce a novel coupled continuous max-flow model, which is dual to the studied convex relaxed optimization formulation and leads to an efficient multiplier augmented algorithm based on the modern convex optimization theory. Moreover, the new continuous max-flow based algorithm was implemented on GPUs to achieve a substantial improvement in computation. Experimental results using public and in-house datasets demonstrate great advantages of the proposed method in terms of both accuracy and efficiency.

  15. A method for semi-automatic segmentation and evaluation of intracranial aneurysms in bone-subtraction computed tomography angiography (BSCTA) images

    NASA Astrophysics Data System (ADS)

    Krämer, Susanne; Ditt, Hendrik; Biermann, Christina; Lell, Michael; Keller, Jörg

    2009-02-01

    The rupture of an intracranial aneurysm has dramatic consequences for the patient. Hence early detection of unruptured aneurysms is of paramount importance. Bone-subtraction computed tomography angiography (BSCTA) has proven to be a powerful tool for detection of aneurysms in particular those located close to the skull base. Most aneurysms though are chance findings in BSCTA scans performed for other reasons. Therefore it is highly desirable to have techniques operating on standard BSCTA scans available which assist radiologists and surgeons in evaluation of intracranial aneurysms. In this paper we present a semi-automatic method for segmentation and assessment of intracranial aneurysms. The only user-interaction required is placement of a marker into the vascular malformation. Termination ensues automatically as soon as the segmentation reaches the vessels which feed the aneurysm. The algorithm is derived from an adaptive region-growing which employs a growth gradient as criterion for termination. Based on this segmentation values of high clinical and prognostic significance, such as volume, minimum and maximum diameter as well as surface of the aneurysm, are calculated automatically. the segmentation itself as well as the calculated diameters are visualised. Further segmentation of the adjoining vessels provides the means for visualisation of the topographical situation of vascular structures associated to the aneurysm. A stereolithographic mesh (STL) can be derived from the surface of the segmented volume. STL together with parameters like the resiliency of vascular wall tissue provide for an accurate wall model of the aneurysm and its associated vascular structures. Consequently the haemodynamic situation in the aneurysm itself and close to it can be assessed by flow modelling. Significant values of haemodynamics such as pressure onto the vascular wall, wall shear stress or pathlines of the blood flow can be computed. Additionally a dynamic flow model can be generated. Thus the presented method supports a better understanding of the clinical situation and assists the evaluation of therapeutic options. Furthermore it contributes to future research addressing intervention planning and prognostic assessment of intracranial aneurysms.

  16. Vapor Phase Hydrogen Peroxide Sanitization of an Isolator for Aseptic Filling of Monoclonal Antibody Drug Product - Hydrogen Peroxide Uptake and Impact on Protein Quality.

    PubMed

    Hubbard, Aaron; Reodl, Thomas; Hui, Ada; Knueppel, Stephanie; Eppler, Kirk; Lehnert, Siegfried; Maa, Yuh-Fun

    2018-03-15

    A monoclonal antibody drug product (DP) manufacturing process was transferred to a different production site, where aseptic filling took place within an isolator that was sanitized using vapor phase hydrogen peroxide (VPHP). A quality-by-design approach was applied for study design to understand the impact of VPHP uptake in the isolator on DP quality. A combination of small-scale and manufacturing-scale studies was performed to evaluate the sensitivity of the monoclonal antibody to hydrogen peroxide (H2O2) as well as VPHP uptake mechanisms during the filling process. The acceptable H2O2 level was determined to be 100 ng/mL for the antibody in the H2O2 spiking study; protein oxidation was observed above this threshold. The most prominent sources of VPHP uptake were identified to be via the silicone tubing assembly (associated with the peristaltic pumps) and open, filled vials. Silicone tubing, an effective depot to H2O2, could absorb VPHP during different stages of the filling process and discharge H2O2 into the DP solution during filling interruptions. A small-scale isolator model, established to simulate manufacturing-scale conditions, was a useful tool in understanding H2O2 uptake in relation to tubing dimensions and VPHP concentration in the isolator air (or atmosphere). Although the tubing assembly had absorbed a substantial amount of VPHP during the decontamination phase, the majority of H2O2 could be removed during tubing cleaning and sterilization in the subsequent isolator aeration phase, demonstrating that H2O2 in the DP solution is taken up primarily via atmospheric VPHP residues in the isolator during filling. Picarro sensor monitoring suggested that the validated VPHP aeration process generates reproducible residual VPHP profiles in isolator air, thus allowing small-scale studies to provide more relevant recommendations on tubing size and interruption time limits for commercial manufacturing. The recommended process parameters were demonstrated to be acceptable and rendered no product quality impact as demonstrated in six consecutive manufacturing batches in the process validation campaign. Overall, this case study would provide process development scientists/engineers an in-depth understanding of the VPHP process and a science-based approach to mitigating DP quality impact. Copyright © 2018, Parenteral Drug Association.

  17. Should idiopathic facial aseptic granuloma be considered granulomatous rosacea? Report of three pediatric cases.

    PubMed

    Neri, Iria; Raone, Beatrice; Dondi, Arianna; Misciali, Cosimo; Patrizi, Annalisa

    2013-01-01

    Idiopathic facial aseptic granuloma (IFAG), or pyodermite froide du visage, is a skin disease reported only in children and characterized by painless red nodules usually located on the cheeks. Its etiology is still unclear, but some authors considered the possibility that IFAG might be included in the spectrum of granulomatous rosacea (GR). The histopathological features of IFAG and GR are quite similar, showing perifolliculitis, granulomas, folliculitis, and lymphocytes and plasmacells around epithelioid histiocytes. In the present article, we discuss three cases in which an association between a facial nodule, compatible with both IFAG and GR, and recurrent chalazia make us support the hypothesis that IFAG should be considered as GR. © 2012 Wiley Periodicals, Inc.

  18. An in vivo study on the effect of coating stability on osteointegration performance of collagen/hyaluronic acid multilayer modified titanium implants.

    PubMed

    Ao, Haiyong; Zong, Jiajia; Nie, Yanjiao; Wan, Yizao; Zheng, Xiebin

    2018-03-01

    Aseptic loosening of implant is one of the main causes of Ti-based implant failure. In our previous work, a novel stable collagen/hyaluronic acid (Col/HA) multilayer modified titanium coatings (TCs) was developed by layer-by-layer (LBL) covalent immobilization technique, which showed enhanced biological properties compared with TCs that were physically absorbed with Col/HA multilayer in vitro . In this study, a rabbit model with femur condyle defect was employed to compare the osteointegration performance of them. Results indicated that Col/HA multilayer with favourable stability could better facilitate osteogenesis around implants and bone-implant contact. The Col/HA multilayer covalent-immobilized TC may reduce aseptic loosening of implant.

  19. Segmentation of 3D ultrasound computer tomography reflection images using edge detection and surface fitting

    NASA Astrophysics Data System (ADS)

    Hopp, T.; Zapf, M.; Ruiter, N. V.

    2014-03-01

    An essential processing step for comparison of Ultrasound Computer Tomography images to other modalities, as well as for the use in further image processing, is to segment the breast from the background. In this work we present a (semi-) automated 3D segmentation method which is based on the detection of the breast boundary in coronal slice images and a subsequent surface fitting. The method was evaluated using a software phantom and in-vivo data. The fully automatically processed phantom results showed that a segmentation of approx. 10% of the slices of a dataset is sufficient to recover the overall breast shape. Application to 16 in-vivo datasets was performed successfully using semi-automated processing, i.e. using a graphical user interface for manual corrections of the automated breast boundary detection. The processing time for the segmentation of an in-vivo dataset could be significantly reduced by a factor of four compared to a fully manual segmentation. Comparison to manually segmented images identified a smoother surface for the semi-automated segmentation with an average of 11% of differing voxels and an average surface deviation of 2mm. Limitations of the edge detection may be overcome by future updates of the KIT USCT system, allowing a fully-automated usage of our segmentation approach.

  20. Flow and habitat effects on juvenile fish abundance in natural and altered flow regimes

    USGS Publications Warehouse

    Freeman, Mary C.; Bowen, Z.H.; Bovee, K.D.; Irwin, E.R.

    2001-01-01

    Conserving biological resources native to large river systems increasingly depends on how flow-regulated segments of these rivers are managed. Improving management will require a better understanding of linkages between river biota and temporal variability of flow and instream habitat. However, few studies have quantified responses of native fish populations to multiyear (>2 yr) patterns of hydrologic or habitat variability in flow-regulated systems. To provide these data, we quantified young-of-year (YOY) fish abundance during four years in relation to hydrologic and habitat variability in two segments of the Tallapoosa River in the southeastern United States. One segment had an unregulated flow regime, whereas the other was flow-regulated by a peak-load generating hydropower dam. We sampled fishes annually and explored how continuously recorded flow data and physical habitat simulation models (PHABSIM) for spring (April-June) and summer (July-August) preceding each sample explained fish abundances. Patterns of YOY abundance in relation to habitat availability (median area) and habitat persistence (longest period with habitat area continuously above the long-term median area) differed between unregulated and flow-regulated sites. At the unregulated site, YOY abundances were most frequently correlated with availability of shallow-slow habitat in summer (10 species) and persistence of shallow-slow and shallow-fast habitat in spring (nine species). Additionally, abundances were negatively correlated with 1-h maximum flow in summer (five species). At the flow-regulated site, YOY abundances were more frequently correlated with persistence of shallow-water habitats (four species in spring; six species in summer) than with habitat availability or magnitude of flow extremes. The associations of YOY with habitat persistence at the flow-regulated site corresponded to the effects of flow regulation on habitat patterns. Flow regulation reduced median flows during spring and summer, which resulted in median availability of shallow-water habitats comparable to the unregulated site. However, habitat persistence was severely reduced by flow fluctuations resulting from pulsed water releases for peak-load power generation. Habitat persistence, comparable to levels in the unregulated site, only occurred during summer when low rainfall or other factors occasionally curtailed power generation. As a consequence, summer-spawning species numerically dominated the fish assemblage at the flow-regulated site; five of six spring-spawning species occurring at both study sites were significantly less abundant at the flow-regulated site. Persistence of native fishes in flow-regulated systems depends, in part, on the seasonal occurrence of stable habitat conditions that facilitate reproduction and YOY survival.

Top