ERIC Educational Resources Information Center
Bredeson, Paul V.
1988-01-01
Reports on a study of the use of employment application blanks as prescreening devices in public school employee selection. Findings suggest two major areas for further research. The first relates to legal compliance with Equal Opportunity Employment guidelines. The second concerns information relevancy to personnel selection. (JAM)
Motte, Anne-France; Diallo, Stéphanie; van den Brink, Hélène; Châteauvieux, Constance; Serrano, Carole; Naud, Carole; Steelandt, Julie; Alsac, Jean-Marc; Aubry, Pierre; Cour, Florence; Pellerin, Olivier; Pineau, Judith; Prognon, Patrice; Borget, Isabelle; Bonan, Brigitte; Martelli, Nicolas
2017-11-01
The aim of this study was to determine relevant items for reporting clinical trials on implantable medical devices (IMDs) and to identify reporting guidelines which include these items. A panel of experts identified the most relevant items for evaluating IMDs from an initial list based on reference papers. We then conducted a systematic review of articles indexed in MEDLINE. We retrieved reporting guidelines from the EQUATOR network's library for health research reporting. Finally, we screened these reporting guidelines to find those using our set of reporting items. Seven relevant reporting items were selected that related to four topics: randomization, learning curve, surgical setting, and device information. A total of 348 reporting guidelines were identified, among which 26 met our inclusion criteria. However, none of the 26 reporting guidelines presented all seven items together. The most frequently reported item was timing of randomization (65%). On the contrary, device information and learning curve effects were poorly specified. To our knowledge, this study is the first to identify specific items related to IMDs in reporting guidelines for clinical trials. We have shown that no existing reporting guideline is totally suitable for these devices. Copyright © 2017 Elsevier Inc. All rights reserved.
Electronic medical devices: a primer for pathologists.
Weitzman, James B
2003-07-01
Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.
Vacuum status-display and sector-conditioning programs
NASA Astrophysics Data System (ADS)
Skelly, J.; Yen, S.
1990-08-01
Two programs have been developed for observation and control of the AGS vacuum system, which include the following notable features: (1) they incorporate a graphical user interface and (2) they are driven by a relational database which describes the vacuum system. The vacuum system comprises some 440 devices organized into 28 vacuum sectors. The status-display program invites menu selection of a sector, interrogates the relational database for relevant vacuum devices, acquires live readbacks and posts a graphical display of their status. The sector-conditioning program likewise invites sector selection, produces the same status display and also implements process control logic on the sector devices to pump the sector down from atmospheric pressure to high vacuum over a period extending several hours. As additional devices are installed in the vacuum system, the devices are added to the relational database; these programs then automatically include the new devices.
Rebholz, Julia; Grossmann, Katharina; Pham, David; Pokhrel, Suman; Mädler, Lutz; Weimar, Udo; Barsan, Nicolae
2016-09-06
Here we present a novel concept for the selective recognition of different target gases with a multilayer semiconducting metal oxide (SMOX)-based sensor device. Direct current (DC) electrical resistance measurements were performed during exposure to CO and ethanol as single gases and mixtures of highly porous metal oxide double- and single-layer sensors obtained by flame spray pyrolysis. The results show that the calculated resistance ratios of the single- and double-layer sensors are a good indicator for the presence of specific gases in the atmosphere, and can constitute some building blocks for the development of chemical logic devices. Due to the inherent lack of selectivity of SMOX-based gas sensors, such devices could be especially relevant for domestic applications.
Rebholz, Julia; Grossmann, Katharina; Pham, David; Pokhrel, Suman; Mädler, Lutz; Weimar, Udo; Barsan, Nicolae
2016-01-01
Here we present a novel concept for the selective recognition of different target gases with a multilayer semiconducting metal oxide (SMOX)-based sensor device. Direct current (DC) electrical resistance measurements were performed during exposure to CO and ethanol as single gases and mixtures of highly porous metal oxide double- and single-layer sensors obtained by flame spray pyrolysis. The results show that the calculated resistance ratios of the single- and double-layer sensors are a good indicator for the presence of specific gases in the atmosphere, and can constitute some building blocks for the development of chemical logic devices. Due to the inherent lack of selectivity of SMOX-based gas sensors, such devices could be especially relevant for domestic applications. PMID:27608028
The Role of Executive Control of Attention and Selective Encoding for Preschoolers' Learning
ERIC Educational Resources Information Center
Roderer, Thomas; Krebs, Saskia; Schmid, Corinne; Roebers, Claudia M.
2012-01-01
Selectivity in encoding, aspects of attentional control and their contribution to learning performance were explored in a sample of preschoolers. While the children are performing a learning task, their encoding of relevant and attention towards irrelevant information was recorded through an eye-tracking device. Recognition of target items was…
Pandit, J J; Popat, M T; Cook, T M; Wilkes, A R; Groom, P; Cooke, H; Kapila, A; O'Sullivan, E
2011-08-01
Faced with the concern that an increasing number of airway management devices were being introduced into clinical practice with little or no prior evidence of their clinical efficacy or safety, the Difficult Airway Society formed a working party (Airway Device Evaluation Project Team) to establish a process by which the airway management community within the profession could itself lead a process of formal device/equipment evaluation. Although there are several national and international regulations governing which products can come on to the market and be legitimately sold, there has hitherto been no formal professional guidance relating to how products should be selected (i.e. purchased). The Airway Device Evaluation Project Team's first task was to formulate such advice, emphasising evidence-based principles. Team discussions led to a definition of the minimum level of evidence needed to make a pragmatic decision about the purchase or selection of an airway device. The Team concluded that this definition should form the basis of a professional standard, guiding those with responsibility for selecting airway devices. We describe how widespread adoption of this professional standard can act as a driver to create an infrastructure in which the required evidence can be obtained. Essential elements are that: (i) the Difficult Airway Society facilitates a coherent national network of research-active units; and (ii) individual anaesthetists in hospital trusts play a more active role in local purchasing decisions, applying the relevant evidence and communicating their purchasing decisions to the Difficult Airway Society. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.
Wagner, Sean R.; Feng, Jiagui; Yoon, Mina; ...
2015-08-25
Using scanning tunneling microscopy and density functional theory, we show that the molecular ordering and orientation of metal phthalocyanine molecules on the deactivated Si surface display a strong dependency on the central transition-metal ion, driven by the degree of orbital hybridization at the heterointerface via selective p – d orbital coupling. As a result, this Letter identifies a selective mechanism for modifying the molecule-substrate interaction which impacts the growth behavior of transition-metal-incorporated organic molecules on a technologically relevant substrate for silicon-based devices.
Some Current Issues in the Design of Flight Training Devices.
ERIC Educational Resources Information Center
Prophet, Wallace W.; And Others
The rationale is developed that training equipment should be selected or designed to furnish what the student needs to know and to be able to do to perform successfully on the operational job. Several considerations relevant to training equipment design from the systems engineering standpoint are examined. Suggested design features based upon…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Laura; Harvey, Stephen P.; Teeter, Glenn
We demonstrate the potential of X-ray photoelectron spectroscopy (XPS) to characterize new carrier-selective contacts (CSC) for solar cell application. We show that XPS not only provides information about the surface chemical properties of the CSC material, but that operando XPS, i.e. under light bias condition, can also directly measure the photovoltage that develops at the CSC/absorber interface, revealing device relevant information without the need of assembling a full solar cell. We present the application of the technique to molybdenum oxide hole-selective contact films on a crystalline silicon absorber.
Selective far-field addressing of coupled quantum dots in a plasmonic nanocavity.
Tang, Jianwei; Xia, Juan; Fang, Maodong; Bao, Fanglin; Cao, Guanjun; Shen, Jianqi; Evans, Julian; He, Sailing
2018-04-27
Plasmon-emitter hybrid nanocavity systems exhibit strong plasmon-exciton interactions at the single-emitter level, showing great potential as testbeds and building blocks for quantum optics and informatics. However, reported experiments involve only one addressable emitting site, which limits their relevance for many fundamental questions and devices involving interactions among emitters. Here we open up this critical degree of freedom by demonstrating selective far-field excitation and detection of two coupled quantum dot emitters in a U-shaped gold nanostructure. The gold nanostructure functions as a nanocavity to enhance emitter interactions and a nanoantenna to make the emitters selectively excitable and detectable. When we selectively excite or detect either emitter, we observe photon emission predominantly from the target emitter with up to 132-fold Purcell-enhanced emission rate, indicating individual addressability and strong plasmon-exciton interactions. Our work represents a step towards a broad class of plasmonic devices that will enable faster, more compact optics, communication and computation.
Controlling release from 3D printed medical devices using CLIP and drug-loaded liquid resins.
Bloomquist, Cameron J; Mecham, Michael B; Paradzinsky, Mark D; Janusziewicz, Rima; Warner, Samuel B; Luft, J Christopher; Mecham, Sue J; Wang, Andrew Z; DeSimone, Joseph M
2018-05-28
Mass customization along with the ability to generate designs using medical imaging data makes 3D printing an attractive method for the fabrication of patient-tailored drug and medical devices. Herein we describe the application of Continuous Liquid Interface Production (CLIP) as a method to fabricate biocompatible and drug-loaded devices with controlled release properties, using liquid resins containing active pharmaceutical ingredients (API). In this work, we characterize how the release kinetics of a model small molecule, rhodamine B-base (RhB), are affected by device geometry, network crosslink density, and the polymer composition of polycaprolactone- and poly (ethylene glycol)-based networks. To demonstrate the applicability of using API-loaded liquid resins with CLIP, the UV stability was evaluated for a panel of clinically-relevant small molecule drugs. Finally, select formulations were tested for biocompatibility, degradation and encapsulation of docetaxel (DTXL) and dexamethasone-acetate (DexAc). Formulations were shown to be biocompatible over the course of 175 days of in vitro degradation and the clinically-relevant drugs could be encapsulated and released in a controlled fashion. This study reveals the potential of the CLIP manufacturing platform to serve as a method for the fabrication of patient-specific medical and drug-delivery devices for personalized medicine. Copyright © 2018. Published by Elsevier B.V.
Detection of heavy metal by paper-based microfluidics.
Lin, Yang; Gritsenko, Dmitry; Feng, Shaolong; Teh, Yi Chen; Lu, Xiaonan; Xu, Jie
2016-09-15
Heavy metal pollution has shown great threat to the environment and public health worldwide. Current methods for the detection of heavy metals require expensive instrumentation and laborious operation, which can only be accomplished in centralized laboratories. Various microfluidic paper-based analytical devices have been developed recently as simple, cheap and disposable alternatives to conventional ones for on-site detection of heavy metals. In this review, we first summarize current development of paper-based analytical devices and discuss the selection of paper substrates, methods of device fabrication, and relevant theories in these devices. We then compare and categorize recent reports on detection of heavy metals using paper-based microfluidic devices on the basis of various detection mechanisms, such as colorimetric, fluorescent, and electrochemical methods. To finalize, the future development and trend in this field are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Solid state SPS microwave generation and transmission study. Volume 2, phase 2: Appendices
NASA Technical Reports Server (NTRS)
Maynard, O. E.
1980-01-01
The solid state sandwich concept for SPS was further defined. The design effort concentrated on the spacetenna, but did include some system analysis for parametric comparison reasons. Basic solid state microwave devices were defined and modeled. An initial conceptual subsystems and system design was performed as well as sidelobe control and system selection. The selected system concept and parametric solid state microwave power transmission system data were assessed relevant to the SPS concept. Although device efficiency was not a goal, the sensitivities to design of this efficiency were parametrically treated. Sidelobe control consisted of various single step tapers, multistep tapers and Gaussian tapers. A hybrid concept using tubes and solid state was evaluated. Thermal analyses are included with emphasis on sensitivities to waste heat radiator form factor, emissivity, absorptivity, amplifier efficiency, material and junction temperature.
Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conover, David R.; Crawford, Alasdair J.; Fuller, Jason
This Protocol provides a set of “best practices” for characterizing energy storage systems (ESSs) and measuring and reporting their performance. It serves as a basis for assessing how an ESS will perform with respect to key performance attributes relevant to different applications. It is intended to provide a valid and accurate basis for the comparison of different ESSs. By achieving the stated purpose, the Protocol will enable more informed decision-making in the selection of ESSs for various stationary applications. The Protocol identifies general information and technical specifications relevant in describing an ESS and also defines a set of test, measurement,more » and evaluation criteria with which to express the performance of ESSs that are intended for energy-intensive and/or power-intensive stationary applications. An ESS includes a storage device, battery management system, and any power conversion systems installed with the storage device. The Protocol is agnostic with respect to the storage technology and the size and rating of the ESS. The Protocol does not apply to single-use storage devices and storage devices that are not coupled with power conversion systems, nor does it address safety, security, or operations and maintenance of ESSs, or provide any pass/fail criteria.« less
Menezes Júnior, Antônio da Silva; Magalhães, Thaís Rodrigues; Morais, Alana de Oliveira Alarcão
2018-01-01
Introduction In the last two decades, the increased number of implants of cardiac implantable electronic devices has been accompanied by an increase in complications, especially infection. Current recommendations for the appropriate treatment of cardiac implantable electronic devices-related infections consist of prolonged antibiotic therapy associated with complete device extraction. The purpose of this study was to analyze the importance of percutaneous extraction in the treatment of these devices infections. Methods A systematic review search was performed in the PubMed, BVS, Cochrane CENTRAL, CAPES, SciELO and ScienceDirect databases. A total of 1,717 studies were identified and subsequently selected according to the eligibility criteria defined by relevance tests by two authors working independently. Results Sixteen studies, describing a total of 3,354 patients, were selected. Percutaneous extraction was performed in 3,081 patients. The average success rate for the complete percutaneous removal of infected devices was 92.4%. Regarding the procedure, the incidence of major complications was 2.9%, and the incidence of minor complications was 8.4%. The average in-hospital mortality of the patients was 5.4%, and the mortality related to the procedure ranged from 0.4 to 3.6%. The mean mortality was 20% after 6 months and 14% after a one-year follow-up. Conclusion Percutaneous extraction is the main technique for the removal of infected cardiac implantable electronic devices, and it presents low rates of complications and mortality related to the procedure.
Virtual Reality and Augmented Reality in Plastic Surgery: A Review.
Kim, Youngjun; Kim, Hannah; Kim, Yong Oock
2017-05-01
Recently, virtual reality (VR) and augmented reality (AR) have received increasing attention, with the development of VR/AR devices such as head-mounted displays, haptic devices, and AR glasses. Medicine is considered to be one of the most effective applications of VR/AR. In this article, we describe a systematic literature review conducted to investigate the state-of-the-art VR/AR technology relevant to plastic surgery. The 35 studies that were ultimately selected were categorized into 3 representative topics: VR/AR-based preoperative planning, navigation, and training. In addition, future trends of VR/AR technology associated with plastic surgery and related fields are discussed.
Virtual Reality and Augmented Reality in Plastic Surgery: A Review
Kim, Youngjun; Kim, Hannah
2017-01-01
Recently, virtual reality (VR) and augmented reality (AR) have received increasing attention, with the development of VR/AR devices such as head-mounted displays, haptic devices, and AR glasses. Medicine is considered to be one of the most effective applications of VR/AR. In this article, we describe a systematic literature review conducted to investigate the state-of-the-art VR/AR technology relevant to plastic surgery. The 35 studies that were ultimately selected were categorized into 3 representative topics: VR/AR-based preoperative planning, navigation, and training. In addition, future trends of VR/AR technology associated with plastic surgery and related fields are discussed. PMID:28573091
Solid state SPS microwave generation and transmission study. Volume 1: Phase 2
NASA Technical Reports Server (NTRS)
Maynard, O. E.
1980-01-01
The solid state sandwich concept for Solar Power Station (SPS) was investigated. The design effort concentrated on the spacetenna, but did include some system analysis for parametric comparison reasons. The study specifically included definition and math modeling of basic solid state microwave devices, an initial conceptual subsystems and system design, sidelobe control and system selection, an assessment of selected system concept and parametric solid state microwave power transmission system data relevant to the SPS concept. Although device efficiency was not a goal, the sensitivities to design of this efficiency were parametrically treated. Sidelobe control consisted of various single step tapers, multistep tapers, and Gaussian tapers. A preliminary assessment of a hybrid concept using tubes and solid state is also included. There is a considerable amount of thermal analysis provided with emphasis on sensitivities to waste heat radiator form factor, emissivity, absorptivity, amplifier efficiency, material and junction temperature.
Tamboli, Vibha K; Bhalla, Nikhil; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Bowen, Jenna L; Allender, Chris J; Estrela, Pedro
2016-12-06
The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.
Concentric-electrode organic electrochemical transistors: case study for selective hydrazine sensing
NASA Astrophysics Data System (ADS)
Pecqueur, S.; Lenfant, S.; Guérin, D.; Alibart, F.; Vuillaume, D.
2017-12-01
We report on hydrazine-sensing organic electrochemical transistors (OECTs) with a design consisting in concentric annular electrodes. The design engineering of these OECTs was motivated by the great potential of using OECT sensing arrays in fields such as bioelectronics. In this work, PEDOT:PSS-based OECTs have been studied as aqueous sensors, specifically sensitive to the lethal hydrazine molecule. These amperometric sensors have many relevant features for the development of hydrazine sensors, such as a sensitivity down to 10-5 M of hydrazine in water, an order of magnitude higher selectivity for hydrazine than for 9 other water soluble common analytes, the capability to recover entirely its base signal after water flushing and a very low voltage operation. The specificity for hydrazine to be sensed by our OECTs is caused by its catalytic oxidation at the gate electrode and enables increasing the output current modulation of the devices. This has permitted the device-geometry study of the whole series of 80 micrometric OECT devices with sub-20-nm PEDOT:PSS layers, channel lengths down to 1 μm and a specific device geometry of coplanar and concentric electrodes. The numerous geometries unravel new aspects of the OECT mechanisms governing the electrochemical sensing behaviours of the device, more particularly the effect of the contacts which are inherent at the micro-scale. By lowering the device cross-talking, micrometric gate-integrated radial OECTs shall contribute to the diminishing of the readout invasiveness and therefore promotes further the development of OECT biosensors.
Boriani, Giuseppe; Diemberger, Igor; Biffi, Mauro; Martignani, Cristian; Ziacchi, Matteo; Bertini, Matteo; Valzania, Cinzia; Bronzetti, Gabriele; Rapezzi, Claudio; Branzi, Angelo
2007-03-01
This viewpoint article discusses the potential for incorporation of atrial defibrillation capabilities in modern multi-chamber devices. In the late 1990s, the possibility of using shock-only therapy to treat selected patients with recurrent atrial fibrillation (AF) was explored in the context of the stand-alone atrial defibrillator. The failure of this strategy can be attributed to the technical limitations of the stand-alone device, low tolerance of atrial shocks, difficulties in patient selection, a lack of predictive knowledge about the evolution of AF, and, last but not least, commercial considerations. An open question is how atrial defibrillation capability may now assume a specific new role in devices implanted for sudden death prevention or cardiac resynchronization. For patients who already have indications for implantable devices, device-based atrial defibrillation appears attractive as a "backup" option for managing AF when preventive pharmacological/electrical measures fail. This and several other personalized hybrid therapeutic approaches await exploration, though assessment of their efficacy is methodologically challenging. Achievement of acceptance by patients is an essential premise for any updated atrial defibrillation strategy. Strategies that are being investigated to improve patient tolerance include waveform shaping, pharmacologic modulation of pain, and patient-activated defibrillation (patients might also perceive the problem of discomfort somewhat differently in the context of a backup therapy). The economic impact of implementing atrial defibrillation features in available devices is progressively decreasing, and financial feasibility need not be a major issue. Future studies should examine clinically relevant outcomes and not be limited (as occurred with stand-alone defibrillators) to technical or other soft endpoints.
Chaotic coordinates for the Large Helical Device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, S. R., E-mail: shudson@pppl.gov; Suzuki, Y.
The theory of quadratic-flux-minimizing (QFM) surfaces is reviewed, and numerical techniques that allow high-order QFM surfaces to be efficiently constructed for experimentally relevant, non-integrable magnetic fields are described. As a practical example, the chaotic edge of the magnetic field in the Large Helical Device (LHD) is examined. A precise technique for finding the boundary surface is implemented, the hierarchy of partial barriers associated with the near-critical cantori is constructed, and a coordinate system, which we call chaotic coordinates, that is based on a selection of QFM surfaces is constructed that simplifies the description of the magnetic field, so that fluxmore » surfaces become “straight” and islands become “square.”.« less
Selection of Two-Phase Flow Patterns at a Simple Junction in Microfluidic Devices
NASA Astrophysics Data System (ADS)
Engl, W.; Ohata, K.; Guillot, P.; Colin, A.; Panizza, P.
2006-04-01
We study the behavior of a confined stream made of two immiscible fluids when it reaches a T junction. Two flow patterns are witnessed: the stream is either directed in only one sidearm, yielding a preferential flow pathway for the dispersed phase, or splits between both. We show that the selection of these patterns is not triggered by the shape of the junction nor by capillary effects, but results from confinement. It can be anticipated in terms of the hydrodynamic properties of the flow. A simple model yielding universal behavior in terms of the relevant adimensional parameters of the problem is presented and discussed.
Technological Solutions for Older People with Alzheimer's Disease: Review.
Maresova, Petra; Tomsone, Signe; Lameski, Petre; Madureira, Joana; Mendes, Ana; Zdravevski, Eftim; Chorbev, Ivan; Trajkovik, Vladimir; Ellen, Moriah; Rodile, Kasper
2018-04-27
In the nineties, numerous studies began to highlight the problem of the increasing number of people with Alzheimer's disease in developed countries, especially in the context of demographic progress. At the same time, the 21st century is typical of the development of advanced technologies that penetrate all areas of human life. Digital devices, sensors, and intelligent applications are tools that can help seniors and allow better communication and control of their caregivers. The aim of the paper is to provide an up-to-date summary of the use of technological solutions for improving health and safety for people with Alzheimer's disease. Firstly, the problems and needs of senior citizens with Alzheimer's disease (AD) and their caregivers are specified. Secondly, a scoping review is performed regarding the technological solutions suggested to assist this specific group of patients. Works obtained from the following libraries used in this scoping review: Web of Science, PubMed, Springer, ACM and IEEE Xplore. Four independent reviewers screened the identified records and selected relevant articles which were published in the period from 2007 to 2018. A total of 6,705 publications were selected. In all, 128 full papers were screened. Results obtained from the relevant studies were furthermore divided into the following categories according to the type and use of technologies: devices, processing, and activity recognition. The leading technological solution in the category of devices are wearables and ambient non-invasive sensors. The introduction and utilization of these technologies however brings about challenges in acceptability, durability, ease of use, communication, and power requirements. Furthermore, in needs to be pointed out that these technological solutions should be based on open standards. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Analysis of Biosignals During Immersion in Computer Games.
Yeo, Mina; Lim, Seokbeen; Yoon, Gilwon
2017-11-17
The number of computer game users is increasing as computers and various IT devices in connection with the Internet are commonplace in all ages. In this research, in order to find the relevance of behavioral activity and its associated biosignal, biosignal changes before and after as well as during computer games were measured and analyzed for 31 subjects. For this purpose, a device to measure electrocardiogram, photoplethysmogram and skin temperature was developed such that the effect of motion artifacts could be minimized. The device was made wearable for convenient measurement. The game selected for the experiments was League of Legends™. Analysis on the pulse transit time, heart rate variability and skin temperature showed increased sympathetic nerve activities during computer game, while the parasympathetic nerves became less active. Interestingly, the sympathetic predominance group showed less change in the heart rate variability as compared to the normal group. The results can be valuable for studying internet gaming disorder.
Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan
2014-01-01
The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.
A novel asynchronous access method with binary interfaces
2008-01-01
Background Traditionally synchronous access strategies require users to comply with one or more time constraints in order to communicate intent with a binary human-machine interface (e.g., mechanical, gestural or neural switches). Asynchronous access methods are preferable, but have not been used with binary interfaces in the control of devices that require more than two commands to be successfully operated. Methods We present the mathematical development and evaluation of a novel asynchronous access method that may be used to translate sporadic activations of binary interfaces into distinct outcomes for the control of devices requiring an arbitrary number of commands to be controlled. With this method, users are required to activate their interfaces only when the device under control behaves erroneously. Then, a recursive algorithm, incorporating contextual assumptions relevant to all possible outcomes, is used to obtain an informed estimate of user intention. We evaluate this method by simulating a control task requiring a series of target commands to be tracked by a model user. Results When compared to a random selection, the proposed asynchronous access method offers a significant reduction in the number of interface activations required from the user. Conclusion This novel access method offers a variety of advantages over traditionally synchronous access strategies and may be adapted to a wide variety of contexts, with primary relevance to applications involving direct object manipulation. PMID:18959797
Gutiérrez-López-Franca, Carlos; Hervás, Ramón; Johnson, Esperanza
2018-01-01
This paper aims to improve activity recognition systems based on skeletal tracking through the study of two different strategies (and its combination): (a) specialized body parts analysis and (b) stricter restrictions for the most easily detectable activities. The study was performed using the Extended Body-Angles Algorithm, which is able to analyze activities using only a single key sample. This system allows to select, for each considered activity, which are its relevant joints, which makes it possible to monitor the body of the user selecting only a subset of the same. But this feature of the system has both advantages and disadvantages. As a consequence, in the past we had some difficulties with the recognition of activities that only have a small subset of the joints of the body as relevant. The goal of this work, therefore, is to analyze the effect produced by the application of several strategies on the results of an activity recognition system based on skeletal tracking joint oriented devices. Strategies that we applied with the purpose of improve the recognition rates of the activities with a small subset of relevant joints. Through the results of this work, we aim to give the scientific community some first indications about which considered strategy is better. PMID:29789478
Sub-0.5 V Highly Stable Aqueous Salt Gated Metal Oxide Electronics
Park, Sungjun; Lee, SeYeong; Kim, Chang-Hyun; Lee, Ilseop; Lee, Won-June; Kim, Sohee; Lee, Byung-Geun; Jang, Jae-Hyung; Yoon, Myung-Han
2015-01-01
Recently, growing interest in implantable bionics and biochemical sensors spurred the research for developing non-conventional electronics with excellent device characteristics at low operation voltages and prolonged device stability under physiological conditions. Herein, we report high-performance aqueous electrolyte-gated thin-film transistors using a sol-gel amorphous metal oxide semiconductor and aqueous electrolyte dielectrics based on small ionic salts. The proper selection of channel material (i.e., indium-gallium-zinc-oxide) and precautious passivation of non-channel areas enabled the development of simple but highly stable metal oxide transistors manifested by low operation voltages within 0.5 V, high transconductance of ~1.0 mS, large current on-off ratios over 107, and fast inverter responses up to several hundred hertz without device degradation even in physiologically-relevant ionic solutions. In conjunction with excellent transistor characteristics, investigation of the electrochemical nature of the metal oxide-electrolyte interface may contribute to the development of a viable bio-electronic platform directly interfacing with biological entities in vivo. PMID:26271456
Reconfigurable Carbon Nanotube Multiplexed Sensing Devices.
Xu, Xinzhao; Clément, Pierrick; Eklöf-Österberg, Johnas; Kelley-Loughnane, Nancy; Moth-Poulsen, Kasper; Chávez, Jorge L; Palma, Matteo
2018-06-26
Here we report on the fabrication of reconfigurable and solution processable nanoscale biosensors with multisensing capability, based on single-walled carbon nanotubes (SWCNTs). Distinct DNA-wrapped (hence water-soluble) CNTs were immobilized from solution onto different prepatterned electrodes on the same chip, via a low-cost dielectrophoresis (DEP) methodology. The CNTs were functionalized with specific, and different, aptamer sequences that were employed as selective recognition elements for biomarkers indicative of stress and neuro-trauma conditions. Multiplexed detection of three different biomarkers was successfully performed, and real-time detection was achieved in serum down to physiologically relevant concentrations of 50 nM, 10 nM, and 500 pM for cortisol, dehydroepiandrosterone-sulfate (DHEAS), and neuropeptide Y (NPY), respectively. Additionally, the fabricated nanoscale devices were shown to be reconfigurable and reusable via a simple cleaning procedure. The general applicability of the strategy presented, and the facile device fabrication from aqueous solution, hold great potential for the development of the next generation of low power consumption portable diagnostic assays for the simultaneous monitoring of different health parameters.
NASA Astrophysics Data System (ADS)
Graham, Matthew W.
2017-02-01
Presently, there exists no reliable in-situ time-resolved method that selectively isolates both the recombination and escape times relevant to photocurrent generation in the ultrafast regime. Transport based measurements lack the required time resolution, while purely optical measurement give a convoluted weighted-average of all electronic dynamics, offering no selectivity for photocurrent generating pathways. Recently, the ultrafast photocurrent (U-PC) autocorrelation method has successfully measured the rate limiting electronic relaxation processes in materials such as graphene, carbon nanotubes, and transition metal dichalcogenide (TMD) materials. Here, we unambiguously derive and experimentally confirm a generic U-PC response function by simultaneously resolving the transient absorption (TA) and U-PC response for highly-efficient (48% IQE at 0 bias) WSe2 devices and twisted bilayer graphene. Surprisingly, both optical TA and electrical U-PC responses give the same E-field-dependent electronic escape and recombination rates. These rates further accurately quantify a material's intrinsic PC generation efficiency. We demonstrate that the chirality of the incident light impacts the U-PC kinetics, suggesting such measurements directly access the ultrafast dynamics need to complex electronic physics such as the valley-Hall effect. By combining E-field dependent ultrafast photocurrent with transient absorption microscopy, we have selectively imaged the dominant kinetic bottlenecks that inhibit photocurrent production in devices made from stacked few-layer TMD materials. This provides a new methodology to intelligently select materials that intrinsically avoid recombination bottlenecks and maximize photocurrent yield.
Mobile phone interference with medical equipment and its clinical relevance: a systematic review.
Lawrentschuk, Nathan; Bolton, Damien M
2004-08-02
To conduct a systematic review of studies on clinically relevant digital mobile phone electromagnetic interference with medical equipment. MEDLINE and SUMSEARCH were searched for the period 1966-2004. The Cochrane Library and Database of Abstracts of Reviews of Effects were also searched for systematic reviews. Studies were eligible if published in a peer-reviewed journal in English, and if they included testing of digital mobile phones for clinically relevant interference with medical equipment used to monitor or treat patients, but not implantable medical devices. As there was considerable heterogeneity in medical equipment studied and the conduct of testing, results were summarised rather than subjected to meta-analysis. Clinically relevant electromagnetic interference (EMI) secondary to mobile phones potentially endangering patients occurred in 45 of 479 devices tested at 900 MHz and 14 of 457 devices tested at 1800 MHz. However, in the largest studies, the prevalence of clinically relevant EMI was low. Most clinically relevant EMI occurred when mobile phones were used within 1 m of medical equipment. Although testing was not standardised between studies and equipment tested was not identical, it is of concern that at least 4% of devices tested in any study were susceptible to clinically relevant EMI. All studies recommend some type of restriction of mobile phone use in hospitals, with use greater than 1 m from equipment and restrictions in clinical areas being the most common.
Cold Environment Assessment Tool (CEAT) User’s Guide for Apple Mobile Devices
2015-06-01
discussion of mobile Android device relevance to the military see, “Android Smartphone Relevance to Military Weather Applications”.5 2. CEAT Inputs To...eating, resting, sleeping , clerical work • Low: Walking, marching without rucksack, drill and ceremony • High: Digging foxhole, running, marching...2013. 5. Sauter, D. Android smartphone relevance to military weather applications. White Sands Missile Range (NM): Army Research Laboratory (US
Low delay and area efficient soft error correction in arbitration logic
Sugawara, Yutaka
2013-09-10
There is provided an arbitration logic device for controlling an access to a shared resource. The arbitration logic device comprises at least one storage element, a winner selection logic device, and an error detection logic device. The storage element stores a plurality of requestors' information. The winner selection logic device selects a winner requestor among the requestors based on the requestors' information received from a plurality of requestors. The winner selection logic device selects the winner requestor without checking whether there is the soft error in the winner requestor's information.
Micro Ring Grating Spectrometer with Adjustable Aperture
NASA Technical Reports Server (NTRS)
Park, Yeonjoon (Inventor); King, Glen C. (Inventor); Elliott, James R. (Inventor); Choi, Sang H. (Inventor)
2012-01-01
A spectrometer includes a micro-ring grating device having coaxially-aligned ring gratings for diffracting incident light onto a target focal point, a detection device for detecting light intensity, one or more actuators, and an adjustable aperture device defining a circular aperture. The aperture circumscribes a target focal point, and directs a light to the detection device. The aperture device is selectively adjustable using the actuators to select a portion of a frequency band for transmission to the detection device. A method of detecting intensity of a selected band of incident light includes directing incident light onto coaxially-aligned ring gratings of a micro-ring grating device, and diffracting the selected band onto a target focal point using the ring gratings. The method includes using an actuator to adjust an aperture device and pass a selected portion of the frequency band to a detection device for measuring the intensity of the selected portion.
Immunologic and tissue biocompatibility of flexible/stretchable electronics and optoelectronics.
Park, Gayoung; Chung, Hyun-Joong; Kim, Kwanghee; Lim, Seon Ah; Kim, Jiyoung; Kim, Yun-Soung; Liu, Yuhao; Yeo, Woon-Hong; Kim, Rak-Hwan; Kim, Stanley S; Kim, Jong-Seon; Jung, Yei Hwan; Kim, Tae-Il; Yee, Cassian; Rogers, John A; Lee, Kyung-Mi
2014-04-01
Recent development of flexible/stretchable integrated electronic sensors and stimulation systems has the potential to establish an important paradigm for implantable electronic devices, where shapes and mechanical properties are matched to those of biological tissues and organs. Demonstrations of tissue and immune biocompatibility are fundamental requirements for application of such kinds of electronics for long-term use in the body. Here, a comprehensive set of experiments studies biocompatibility on four representative flexible/stretchable device platforms, selected on the basis of their versatility and relevance in clinical usage. The devices include flexible silicon field effect transistors (FETs) on polyimide and stretchable silicon FETs, InGaN light-emitting diodes (LEDs), and AlInGaPAs LEDs, each on low modulus silicone substrates. Direct cytotoxicity measured by exposure of a surrogate fibroblast line and leachable toxicity by minimum essential medium extraction testing reveal that all of these devices are non-cytotoxic. In vivo immunologic and tissue biocompatibility testing in mice indicate no local inflammation or systemic immunologic responses after four weeks of subcutaneous implantation. The results show that these new classes of flexible implantable devices are suitable for introduction into clinical studies as long-term implantable electronics. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cruz-Piris, Luis; Rivera, Diego; Marsa-Maestre, Ivan; de la Hoz, Enrique; Velasco, Juan R
2018-03-20
Internet growth has generated new types of services where the use of sensors and actuators is especially remarkable. These services compose what is known as the Internet of Things (IoT). One of the biggest current challenges is obtaining a safe and easy access control scheme for the data managed in these services. We propose integrating IoT devices in an access control system designed for Web-based services by modelling certain IoT communication elements as resources. This would allow us to obtain a unified access control scheme between heterogeneous devices (IoT devices, Internet-based services, etc.). To achieve this, we have analysed the most relevant communication protocols for these kinds of environments and then we have proposed a methodology which allows the modelling of communication actions as resources. Then, we can protect these resources using access control mechanisms. The validation of our proposal has been carried out by selecting a communication protocol based on message exchange, specifically Message Queuing Telemetry Transport (MQTT). As an access control scheme, we have selected User-Managed Access (UMA), an existing Open Authorization (OAuth) 2.0 profile originally developed for the protection of Internet services. We have performed tests focused on validating the proposed solution in terms of the correctness of the access control system. Finally, we have evaluated the energy consumption overhead when using our proposal.
2018-01-01
Internet growth has generated new types of services where the use of sensors and actuators is especially remarkable. These services compose what is known as the Internet of Things (IoT). One of the biggest current challenges is obtaining a safe and easy access control scheme for the data managed in these services. We propose integrating IoT devices in an access control system designed for Web-based services by modelling certain IoT communication elements as resources. This would allow us to obtain a unified access control scheme between heterogeneous devices (IoT devices, Internet-based services, etc.). To achieve this, we have analysed the most relevant communication protocols for these kinds of environments and then we have proposed a methodology which allows the modelling of communication actions as resources. Then, we can protect these resources using access control mechanisms. The validation of our proposal has been carried out by selecting a communication protocol based on message exchange, specifically Message Queuing Telemetry Transport (MQTT). As an access control scheme, we have selected User-Managed Access (UMA), an existing Open Authorization (OAuth) 2.0 profile originally developed for the protection of Internet services. We have performed tests focused on validating the proposed solution in terms of the correctness of the access control system. Finally, we have evaluated the energy consumption overhead when using our proposal. PMID:29558406
Method and apparatus for monitoring a hydrocarbon-selective catalytic reduction device
Schmieg, Steven J; Viola, Michael B; Cheng, Shi-Wai S; Mulawa, Patricia A; Hilden, David L; Sloane, Thompson M; Lee, Jong H
2014-05-06
A method for monitoring a hydrocarbon-selective catalytic reactor device of an exhaust aftertreatment system of an internal combustion engine operating lean of stoichiometry includes injecting a reductant into an exhaust gas feedstream upstream of the hydrocarbon-selective catalytic reactor device at a predetermined mass flowrate of the reductant, and determining a space velocity associated with a predetermined forward portion of the hydrocarbon-selective catalytic reactor device. When the space velocity exceeds a predetermined threshold space velocity, a temperature differential across the predetermined forward portion of the hydrocarbon-selective catalytic reactor device is determined, and a threshold temperature as a function of the space velocity and the mass flowrate of the reductant is determined. If the temperature differential across the predetermined forward portion of the hydrocarbon-selective catalytic reactor device is below the threshold temperature, operation of the engine is controlled to regenerate the hydrocarbon-selective catalytic reactor device.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures.
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2017-04-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9 m -by-10 m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user's wrist is stationary.
SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures
Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani
2018-01-01
Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9m-by-10m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user’s wrist is stationary. PMID:29683151
Anatomy of the patent foramen ovale for the interventionalist.
McKenzie, Jeff A; Edwards, William D; Hagler, Donald J
2009-05-01
Patent foramen ovale (PFO) is an interatrial communication whose management is controversial. Several manufacturers have submitted protocols for Food and Drug Administration (FDA) approval of their PFO closure device. The purpose of this study was to define anatomy relevant to percutaneous PFO closure, validate the clinical observation that most PFOs contain little tissue rim at the aorta, comment on proposed closure guidelines, and to discuss approaches to PFO closure. From the Mayo Clinic Tissue Registry, five normal hearts with PFO were selected from each sex from the first 10 decades of life (n = 100). Measurements (mm) included PFO length, diameter, and distance from FO-superior vena cava (SVC) and FO-aortic annulus (AoAn). Patient age, weight, and height were obtained from autopsy reports, and body surface area (BSA) was calculated. PFO length and diameter increased with age (P = 0.029 and 0.001, respectively), and FO-SVC and FO-AoAn increased with BSA (P
Tomaselli, Simona; Giovanella, Umberto; Pagano, Katiuscia; Leone, Giuseppe; Zanzoni, Serena; Assfalg, Michael; Meinardi, Francesco; Molinari, Henriette; Botta, Chiara; Ragona, Laura
2013-10-14
New strategies are requested for the preparation of bioinspired host-guest complexes to be employed in technologically relevant applications, as sensors and optoelectronic devices. We report here a new approach employing a single monomeric protein as host for the strongly fluorescent rhodamine dye. The selected protein, belonging to the intracellular lipid binding protein family, fully encapsulates one rhodamine molecule inside its cavity forming a host-guest complex stabilized by H and π-hydrogen bonds, a salt bridge, and favorable hydrophobic contacts, as revealed by the NMR derived structural model. The protein-dye solutions are easily processable and form homogeneous thin films exhibiting excellent photophysical and morphological properties, as derived from photoluminescence and AFM data. The obtained results represent the proof of concept of the viability of this bio host-guest system for the development of bioinspired optoelectronic devices.
Towards on-chip time-resolved thermal mapping with micro-/nanosensor arrays
2012-01-01
In recent years, thin-film thermocouple (TFTC) array emerged as a versatile candidate in micro-/nanoscale local temperature sensing for its high resolution, passive working mode, and easy fabrication. However, some key issues need to be taken into consideration before real instrumentation and industrial applications of TFTC array. In this work, we will demonstrate that TFTC array can be highly scalable from micrometers to nanometers and that there are potential applications of TFTC array in integrated circuits, including time-resolvable two-dimensional thermal mapping and tracing the heat source of a device. Some potential problems and relevant solutions from a view of industrial applications will be discussed in terms of material selection, multiplexer reading, pattern designing, and cold-junction compensation. We show that the TFTC array is a powerful tool for research fields such as chip thermal management, lab-on-a-chip, and other novel electrical, optical, or thermal devices. PMID:22931306
Hemkens, Lars G; Hilden, Kristian M; Hartschen, Stephan; Kaiser, Thomas; Didjurgeit, Ulrike; Hansen, Roland; Bender, Ralf; Sawicki, Peter T
2008-08-01
In addition to the metrological quality of international normalized ratio (INR) monitoring devices used in patients' self-management of long-term anticoagulation, the effectiveness of self-monitoring with such devices has to be evaluated under real-life conditions with a focus on clinical implications. An approach to evaluate the clinical significance of inaccuracies is the error-grid analysis as already established in self-monitoring of blood glucose. Two anticoagulation monitors were compared in a real-life setting and a novel error-grid instrument for oral anticoagulation has been evaluated. In a randomized crossover study 16 patients performed self-management of anticoagulation using the INRatio and the CoaguChek S system. Main outcome measures were clinically relevant INR differences according to established criteria and to the error-grid approach. A lower rate of clinically relevant disagreements according to Anderson's criteria was found with CoaguChek S than with INRatio without statistical significance (10.77% vs. 12.90%; P = 0.787). Using the error-grid we found principally consistent results: More measurement pairs with discrepancies of no or low clinical relevance were found with CoaguChek S, whereas with INRatio we found more differences with a moderate clinical relevance. A high rate of patients' satisfaction with both of the point of care devices was found with only marginal differences. A principal appropriateness of the investigated point-of-care devices to adequately monitor the INR is shown. The error-grid is useful for comparing monitoring methods with a focus on clinical relevance under real-life conditions beyond assessing the pure metrological quality, but we emphasize that additional trials using this instrument with larger patient populations are needed to detect differences in clinically relevant disagreements.
Artificial intelligence applications in the intensive care unit.
Hanson, C W; Marshall, B E
2001-02-01
To review the history and current applications of artificial intelligence in the intensive care unit. The MEDLINE database, bibliographies of selected articles, and current texts on the subject. The studies that were selected for review used artificial intelligence tools for a variety of intensive care applications, including direct patient care and retrospective database analysis. All literature relevant to the topic was reviewed. Although some of the earliest artificial intelligence (AI) applications were medically oriented, AI has not been widely accepted in medicine. Despite this, patient demographic, clinical, and billing data are increasingly available in an electronic format and therefore susceptible to analysis by intelligent software. Individual AI tools are specifically suited to different tasks, such as waveform analysis or device control. The intensive care environment is particularly suited to the implementation of AI tools because of the wealth of available data and the inherent opportunities for increased efficiency in inpatient care. A variety of new AI tools have become available in recent years that can function as intelligent assistants to clinicians, constantly monitoring electronic data streams for important trends, or adjusting the settings of bedside devices. The integration of these tools into the intensive care unit can be expected to reduce costs and improve patient outcomes.
Jiménez-Solano, Alberto; Galisteo-López, Juan F; Míguez, Hernán
2018-04-19
Tailoring the interaction of electromagnetic radiation with matter is central to the development of optoelectronic devices. This becomes particularly relevant for a new generation of devices offering the possibility of solution processing with competitive efficiencies as well as new functionalities. These devices, containing novel materials such as inorganic colloidal quantum dots or hybrid organic-inorganic lead halide perovskites, commonly demand thin (tens of nanometers) active layers in order to perform optimally and thus maximizing the way electromagnetic radiation interacts with these layers is essential. In this Perspective, we discuss the relevance of tailoring the optical environment of the active layer in an optoelectronic device and illustrate it with two real-world systems comprising photovoltaic cells and light emitting devices.
Strachan, Patricia H.; de Laat, Sonya; Carroll, Sandra L.; Schwartz, Lisa; Vaandering, Katie; Toor, Gurjit K.; Arthur, Heather M.
2012-01-01
Background Implantable cardioverter defibrillators (ICDs) are increasingly offered to patients for primary prevention of sudden cardiac death. Candidates for ICD receive ICD-related patient education material when they make decisions to consent or decline a primary prevention ICD. Printed patient education material directed at ICD candidates has not been the focus of direct appraisal. Objective We evaluated the readability and content of ICD-related print education materials made available to patients who were enrolled in a study involving patient decision making for ICD from 3 ICD sites in southern Ontario, Canada. Methods All ICD print materials referred to during interviews and/or that were available in ICD site waiting rooms were collected for analysis. Readability testing was conducted using the SMOG (“simple measurement of gobbledygook”) and Fry methods. The material was evaluated according to selected plain-language criteria, thematic content analysis, and rhetoric analysis. Results Twenty-one print materials were identified and analyzed. Documents were authored by device manufacturers, tertiary care hospitals, and cardiac support organizations. Although many documents adhered to plain-language recommendations, text-reading levels were higher than recommended. Twelve major content themes were identified. Content focused heavily on the positive aspects of living with the device to the exclusion of other possible information that could be relevant to the decisions that patients made. Conclusions Print-based patient education materials for ICD candidates are geared to a highly literate population. The focus on positive information to the exclusion of potentially negative aspects of the ICD, or alternatives to accepting 1, could influence and/or confuse patients about the purpose and implications of this medical device. Development of print materials is indicated that includes information about possible problems and that would be relevant for the multicultural and debilitated population who may require ICDs. The findings are highly relevant for nurses who care for primary prevention ICD candidates. PMID:21926915
Galletti, Giuseppe; Sung, Matthew S; Vahdat, Linda T; Shah, Manish A; Santana, Steven M; Altavilla, Giuseppe; Kirby, Brian J; Giannakakou, Paraskevi
2014-01-07
Circulating tumor cells (CTCs) have emerged as a reliable source of tumor cells, and their concentration has prognostic implications. CTC capture offers real-time access to cancer tissue without the need of an invasive biopsy, while their phenotypic and molecular interrogation can provide insight into the biological changes of the tumor that occur during treatment. The majority of the CTC capture methods are based on EpCAM expression as a surface marker of tumor-derived cells. However, EpCAM protein expression levels can be significantly down regulated during cancer progression as a consequence of the process of epithelial to mesenchymal transition. In this paper, we describe a novel HER2 (Human Epidermal Receptor 2)-based microfluidic device for the isolation of CTCs from peripheral blood of patients with HER2-expressing solid tumors. We selected HER2 as an alternative to EpCAM as the receptor is biologically and therapeutically relevant in several solid tumors, like breast cancer (BC), where it is overexpressed in 30% of the patients and expressed in 90%, and gastric cancer (GC), in which HER2 presence is identified in more than 60% of the cases. We tested the performance of various anti HER2 antibodies in a panel of nine different BC cell lines with varying HER2 protein expression levels, using immunoblotting, confocal microscopy, live cells imaging and flow cytometry analyses. The antibody associated with the highest capture efficiency and sensitivity for HER2 expressing cells on the microfluidic device was the one that performed best in live cells imaging and flow cytometry assays as opposed to the fixed cell analyses, suggesting that recognition of the native conformation of the HER2 extracellular epitope on living cells was essential for specificity and sensitivity of CTC capture. Next, we tested the performance of the HER2 microfluidic device using blood from metastatic breast and gastric cancer patients. The HER2 microfluidic device exhibited CTC capture in 9/9 blood samples. Thus, the described HER2-based microfluidic device can be considered as a valid clinically relevant method for CTC capture in HER2 expressing solid cancers.
K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.
K3EDTA Vacuum Tubes Validation for Routine Hematological Testing
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare
2012-01-01
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K3EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K3EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests. PMID:22888448
News and Events - Nanodelivery Systems and Devices Branch
The latest news from the Nanodelivery Systems and Devices Branch and the Alliance, as well as upcoming and past events attended by the Nanodelivery Systems and Devices Branchstaff, and relevant upcoming scientific meetings.
NASA Technical Reports Server (NTRS)
Studenick, D. K. (Inventor)
1977-01-01
An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.
Evaluating the ergonomics of BCI devices for research and experimentation.
Ekandem, Joshua I; Davis, Timothy A; Alvarez, Ignacio; James, Melva T; Gilbert, Juan E
2012-01-01
The use of brain computer interface (BCI) devices in research and applications has exploded in recent years. Applications such as lie detectors that use functional magnetic resonance imaging (fMRI) to video games controlled using electroencephalography (EEG) are currently in use. These developments, coupled with the emergence of inexpensive commercial BCI headsets, such as the Emotiv EPOC ( http://emotiv.com/index.php ) and the Neurosky MindWave, have also highlighted the need of performing basic ergonomics research since such devices have usability issues, such as comfort during prolonged use, and reduced performance for individuals with common physical attributes, such as long or coarse hair. This paper examines the feasibility of using consumer BCIs in scientific research. In particular, we compare user comfort, experiment preparation time, signal reliability and ease of use in light of individual differences among subjects for two commercially available hardware devices, the Emotiv EPOC and the Neurosky MindWave. Based on these results, we suggest some basic considerations for selecting a commercial BCI for research and experimentation. STATEMENT OF RELEVANCE: Despite increased usage, few studies have examined the usability of commercial BCI hardware. This study assesses usability and experimentation factors of two commercial BCI models, for the purpose of creating basic guidelines for increased usability. Finding that more sensors can be less comfortable and accurate than devices with fewer sensors.
Bezdjian, Aren; Bruijnzeel, Hanneke; Daniel, Sam J; Grolman, Wilko; Thomeer, Hans G X M
2017-10-01
To delineate the auditory functional improvement and peri-operative outcomes of the Sophono™ transcutaneous bone conduction device. Eligible articles presenting patients implanted with the Sophono™ were identified through a comprehensive search of PubMed and Embase electronic databases. All relevant articles were reviewed to justify inclusion independently by 2 authors. Studies that successfully passed critical appraisal for directness of evidence and risk of bias were included. From a total of 125 articles, 8 studies encompassing 86 patients using 99 implants were selected. Most patients (79.1%) were children. Ear atresia (67.5%) was the most frequently reported indication for Sophono™ implantation. Overall pure tone average auditory improvement was 31.10 (±8.29) decibel. During a mean follow-up time of 12.48 months, 25 patients (29%) presented with post-operative complications from which 3 were deemed as serious implant-related adverse events (3.5%). The Sophono™ transcutaneous bone conduction device shows promising functional improvement, no intra-operative complications and minor post-operative skin related complications. If suitable, the device could be a proposed solution for the rehabilitation of hearing in children meeting eligibility criteria. A wearing schedule must be implemented in order to reduce magnet-related skin complications. Copyright © 2017 Elsevier B.V. All rights reserved.
Enhancing Electromagnetic Side-Channel Analysis in an Operational Environment
NASA Astrophysics Data System (ADS)
Montminy, David P.
Side-channel attacks exploit the unintentional emissions from cryptographic devices to determine the secret encryption key. This research identifies methods to make attacks demonstrated in an academic environment more operationally relevant. Algebraic cryptanalysis is used to reconcile redundant information extracted from side-channel attacks on the AES key schedule. A novel thresholding technique is used to select key byte guesses for a satisfiability solver resulting in a 97.5% success rate despite failing for 100% of attacks using standard methods. Two techniques are developed to compensate for differences in emissions from training and test devices dramatically improving the effectiveness of cross device template attacks. Mean and variance normalization improves same part number attack success rates from 65.1% to 100%, and increases the number of locations an attack can be performed by 226%. When normalization is combined with a novel technique to identify and filter signals in collected traces not related to the encryption operation, the number of traces required to perform a successful attack is reduced by 85.8% on average. Finally, software-defined radios are shown to be an effective low-cost method for collecting side-channel emissions in real-time, eliminating the need to modify or profile the target encryption device to gain precise timing information.
Polymer materials and component evaluation in acidic-radiation environments
NASA Astrophysics Data System (ADS)
Celina, M.; Gillen, K. T.; Malone, G. M.; Clough, R. L.; Nelson, W. H.
2001-07-01
Polymeric materials used for cable/wire insulation, electrical connectors, O-rings, seals, and in critical components such as motors, level switches and resistive thermo-devices were evaluated under accelerated degradation conditions in combined radiation-oxidative elevated-temperature acidic-vapor (nitric/oxalic) environments relevant to conditions in isotope processing facilities. Experiments included the assessment of individual materials such as PEEK, polyimides, polyolefin based cable insulation, EPDM rubbers, various epoxy systems, commercial caulking materials as well as some functional testing of components. We discuss how to conduct laboratory experiments to simulate such complex hostile environments, describe some degradation effects encountered, and evaluate the impact on appropriate material and component selection.
Understanding Monitoring Technologies for Adults With Pain: Systematic Literature Review
Rodríguez, Iyubanit; Gerea, Carmen; Fuentes, Carolina; Rossel, Pedro O; Marques, Maíra; Campos, Mauricio
2017-01-01
Background Monitoring of patients may decrease treatment costs and improve quality of care. Pain is the most common health problem that people seek help for in hospitals. Therefore, monitoring patients with pain may have significant impact in improving treatment. Several studies have studied factors affecting pain; however, no previous study has reviewed the contextual information that a monitoring system may capture to characterize a patient’s situation. Objective The objective of this study was to conduct a systematic review to (1) determine what types of technologies have been used to monitor adults with pain, and (2) construct a model of the context information that may be used to implement apps and devices aimed at monitoring adults with pain. Methods A literature search (2005-2015) was conducted in electronic databases pertaining to medical and computer science literature (PubMed, Science Direct, ACM Digital Library, and IEEE Xplore) using a defined search string. Article selection was done through a process of removing duplicates, analyzing title and abstract, and then reviewing the full text of the article. Results In the final analysis, 87 articles were included and 53 of them (61%) used technologies to collect contextual information. A total of 49 types of context information were found and a five-dimension (activity, identity, wellness, environment, physiological) model of context information to monitor adults with pain was proposed, expanding on a previous model. Most technological interfaces for pain monitoring were wearable, possibly because they can be used in more realistic contexts. Few studies focused on older adults, creating a relevant avenue of research on how to create devices for users that may have impaired cognitive skills or low digital literacy. Conclusions The design of monitoring devices and interfaces for adults with pain must deal with the challenge of selecting relevant contextual information to understand the user’s situation, and not overburdening or inconveniencing users with information requests. A model of contextual information may be used by researchers to choose possible contextual information that may be monitored during studies on adults with pain. PMID:29079550
System and method for programmable bank selection for banked memory subsystems
Blumrich, Matthias A.; Chen, Dong; Gara, Alan G.; Giampapa, Mark E.; Hoenicke, Dirk; Ohmacht, Martin; Salapura, Valentina; Sugavanam, Krishnan
2010-09-07
A programmable memory system and method for enabling one or more processor devices access to shared memory in a computing environment, the shared memory including one or more memory storage structures having addressable locations for storing data. The system comprises: one or more first logic devices associated with a respective one or more processor devices, each first logic device for receiving physical memory address signals and programmable for generating a respective memory storage structure select signal upon receipt of pre-determined address bit values at selected physical memory address bit locations; and, a second logic device responsive to each of the respective select signal for generating an address signal used for selecting a memory storage structure for processor access. The system thus enables each processor device of a computing environment memory storage access distributed across the one or more memory storage structures.
MacLean, Mary H; Giesbrecht, Barry
2015-07-01
Task-relevant and physically salient features influence visual selective attention. In the present study, we investigated the influence of task-irrelevant and physically nonsalient reward-associated features on visual selective attention. Two hypotheses were tested: One predicts that the effects of target-defining task-relevant and task-irrelevant features interact to modulate visual selection; the other predicts that visual selection is determined by the independent combination of relevant and irrelevant feature effects. These alternatives were tested using a visual search task that contained multiple targets, placing a high demand on the need for selectivity, and that was data-limited and required unspeeded responses, emphasizing early perceptual selection processes. One week prior to the visual search task, participants completed a training task in which they learned to associate particular colors with a specific reward value. In the search task, the reward-associated colors were presented surrounding targets and distractors, but were neither physically salient nor task-relevant. In two experiments, the irrelevant reward-associated features influenced performance, but only when they were presented in a task-relevant location. The costs induced by the irrelevant reward-associated features were greater when they oriented attention to a target than to a distractor. In a third experiment, we examined the effects of selection history in the absence of reward history and found that the interaction between task relevance and selection history differed, relative to when the features had previously been associated with reward. The results indicate that under conditions that demand highly efficient perceptual selection, physically nonsalient task-irrelevant and task-relevant factors interact to influence visual selective attention.
21 CFR 866.2360 - Selective culture medium.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Selective culture medium. 866.2360 Section 866.2360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2360 Selective culture...
21 CFR 866.2360 - Selective culture medium.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Selective culture medium. 866.2360 Section 866.2360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2360 Selective culture...
21 CFR 866.2360 - Selective culture medium.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Selective culture medium. 866.2360 Section 866.2360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2360 Selective culture...
21 CFR 866.2360 - Selective culture medium.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Selective culture medium. 866.2360 Section 866.2360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2360 Selective culture...
21 CFR 866.2360 - Selective culture medium.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Selective culture medium. 866.2360 Section 866.2360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2360 Selective culture...
High-Bandgap Silicon Nanocrystal Solar Cells: Device Fabrication, Characterization, and Modeling
NASA Astrophysics Data System (ADS)
Löper, Philipp; Canino, Mariaconcetta; Schnabel, Manuel; Summonte, Caterina; Janz, Stefan; Zacharias, Margit
Silicon nanocrystals (Si NCs) embedded in Si-based dielectrics provide a Si-based high-bandgap material (1.7 eV) and enable the construction of crystalline Si tandem solar cells. This chapter focusses on Si NC embedded in silicon carbide, because silicon carbide offers electrical conduction through the matrix material. The material development is reviewed, and optical modeling is introduced as a powerful method to monitor the four material components, amorphous and crystalline silicon as well as amorphous and crystalline silicon carbide. In the second part of this chapter, recent device developments for the photovoltaic characterization of Si NCs are examined. The controlled growth of Si NCs involves high-temperature annealing which deteriorates the properties of any previously established selective contacts. A membrane-based device is presented to overcome these limitations. In this approach, the formation of both selective contacts is carried out after high-temperature annealing and is therefore not affected by the latter. We examine p-i-n solar cells with an intrinsic region made of Si NCs embedded in silicon carbide. Device failure due to damaged insulation layers is analyzed by light beam-induced current measurements. An optical model of the device is presented for improving the cell current. A characterization scheme for Si NC p-i-n solar cells is presented which aims at determining the fundamental transport and recombination properties, i.e., the effective mobility lifetime product, of the nanocrystal layer at device level. For this means, an illumination-dependent analysis of Si NC p-i-n solar cells is carried out within the framework of the constant field approximation. The analysis builds on an optical device model, which is used to assess the photogenerated current in each of the device layers. Illumination-dependent current-voltage curves are modelled with a voltage-dependent current collection function with only two free parameters, and excellent agreement is found between theory and experiment. An effective mobility lifetime product of 10-10 cm2/V is derived and confirmed independently from an alternative method. The procedure discussed in this chapter is proposed as a characterization scheme for further material development, providing an optimization parameter (the effective mobility lifetime product) relevant for the photovoltaic performance of Si NC films.
External Mechanical Devices and Vascular Surgery for Erectile Dysfunction.
Trost, Landon W; Munarriz, Ricardo; Wang, Run; Morey, Allen; Levine, Laurence
2016-11-01
The field of sexual medicine is continuously advancing, with novel outcomes reported on a regular basis. Given the rapid evolution, updated guidelines are essential to inform practicing clinicians on best practices. To summarize the current literature and provide clinical guidelines on penile traction therapy, vacuum erection devices, and penile revascularization. A consensus panel was held with leading sexual medicine experts during the 2015 International Consultation on Sexual Medicine (ICSM). Relevant literature was reviewed and graded based on Oxford criteria to develop evidence-based guideline and consensus statements. The development of clinically relevant guidelines. Penile traction therapy is a viable therapy to modestly improve penile length as a primary therapy, before penile prosthesis placement in men with decreased penile length or after surgery for Peyronie's disease. It also might have a role in the acute phase of Peyronie's disease but has inconsistent outcomes in the long-term phase. Vacuum erection devices are effective in creating an erection satisfactory for intercourse, even in difficult-to-treat populations. They also might be used in the post-prostatectomy setting to maintain penile length but have insufficient evidence as a penile rehabilitation therapy. For vasculogenic erectile dysfunction, men with suspected arterial insufficiency can be evaluated with penile Duplex Doppler ultrasonography and confirmatory angiography. Penile revascularization procedures have consistently demonstrated benefits in very select patient populations; however, inadequate data exists to suggest the superiority of one technique. Men with vascular risk factors are likely poor candidates for penile revascularization, although veno-occlusive dysfunction and age are less significant. Therapies for treating primary veno-occlusive dysfunction are not recommended and should be reserved for clinical trials. Since the prior ICSM meeting, multiple developments have occurred in external mechanical devices and penile revascularization for the treatment of erectile and sexual dysfunction. Sexual medicine clinicians are encouraged to review and incorporate recommendations as applicable to their scope of practice. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
2016-10-17
AFRL-AFOSR-JP-TR-2016-0082 Nanofluidic Pre -Concentration Devices for Enhancing the Detection Sensitivity and Selectivity of Biomarkers for Human...Nanofluidic Pre -Concentration Devices for Enhancing the Detection Sensitivity and Selectivity of Biomarkers for Human Performance Monitoring 5a...SUBJECT TERMS Biomarkers, Nanofluidics, Pre -concentration Devices, Sensing, AOARD 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18
Composite patterning devices for soft lithography
Rogers, John A.; Menard, Etienne
2007-03-27
The present invention provides methods, devices and device components for fabricating patterns on substrate surfaces, particularly patterns comprising structures having microsized and/or nanosized features of selected lengths in one, two or three dimensions. The present invention provides composite patterning devices comprising a plurality of polymer layers each having selected mechanical properties, such as Young's Modulus and flexural rigidity, selected physical dimensions, such as thickness, surface area and relief pattern dimensions, and selected thermal properties, such as coefficients of thermal expansion, to provide high resolution patterning on a variety of substrate surfaces and surface morphologies.
Method to monitor HC-SCR catalyst NOx reduction performance for lean exhaust applications
Viola, Michael B [Macomb Township, MI; Schmieg, Steven J [Troy, MI; Sloane, Thompson M [Oxford, MI; Hilden, David L [Shelby Township, MI; Mulawa, Patricia A [Clinton Township, MI; Lee, Jong H [Rochester Hills, MI; Cheng, Shi-Wai S [Troy, MI
2012-05-29
A method for initiating a regeneration mode in selective catalytic reduction device utilizing hydrocarbons as a reductant includes monitoring a temperature within the aftertreatment system, monitoring a fuel dosing rate to the selective catalytic reduction device, monitoring an initial conversion efficiency, selecting a determined equation to estimate changes in a conversion efficiency of the selective catalytic reduction device based upon the monitored temperature and the monitored fuel dosing rate, estimating changes in the conversion efficiency based upon the determined equation and the initial conversion efficiency, and initiating a regeneration mode for the selective catalytic reduction device based upon the estimated changes in conversion efficiency.
Optical investigations of nanostructured oxides and semiconductors
NASA Astrophysics Data System (ADS)
Irvin, Patrick Richard
This work is motivated by the prospect of building a quantum computer: a device that would allow physicists to explore quantum mechanics more deeply, and allow everyone else to keep their credit card numbers safe on the Internet. In this thesis we explore two classes of materials that are relevant to a proposed quantum computer architecture: oxides and semiconductors. Systems with a ferroelectric to paraelectric transition in the vicinity of room temperature are useful for devices. We investigate strained-SrTiO 3, which is ferroelectric at room-temperature, and a composite material of (Ba,Sr)TiO3 and MgO. We present optical techniques to measure electron spin dynamics with GHz dynamical bandwidth, transform-limited spectral selectivity, and phase-sensitive detection. We demonstrate this technique by measuring GHz-spin precession in n-GaAs. We also describe our efforts to optically probe InAs/GaAs and GaAs/AlGaAs quantum dots. Nanoscale devices with photonic properties have been the subject of intense research over the past decade. Potential nanophotonic applications include communications, polarization-sensitive detectors, and solar power generation. Here we show photosensitivity of a nanoscale detector written at the interface between two oxides.
Redefining Cheminformatics with Intuitive Collaborative Mobile Apps
Clark, Alex M; Ekins, Sean; Williams, Antony J
2012-01-01
Abstract The proliferation of mobile devices such as smartphones and tablet computers has recently been extended to include a growing ecosystem of increasingly sophisticated chemistry software packages, commonly known as apps. The capabilities that these apps can offer to the practicing chemist are approaching those of conventional desktop-based software, but apps tend to be focused on a relatively small range of tasks. To overcome this, chemistry apps must be able to seamlessly transfer data to other apps, and through the network to other devices, as well as to other platforms, such as desktops and servers, using documented file formats and protocols whenever possible. This article describes the development and state of the art with regard to chemistry-aware apps that make use of facile data interchange, and some of the scenarios in which these apps can be inserted into a chemical information workflow to increase productivity. A selection of contemporary apps is used to demonstrate their relevance to pharmaceutical research. Mobile apps represent a novel approach for delivery of cheminformatics tools to chemists and other scientists, and indications suggest that mobile devices represent a disruptive technology for drug discovery, as they have been to many other industries. PMID:23198002
Lucas, Anne D; Nagaraja, Srinidhi; Gordon, Edward A; Hitchins, Victoria M
2015-01-01
Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained significantly more bone debris than those soiled and cleaned once. Significantly more bone cement was retained in the more complex lumen structures. This information may be useful in designing reusable orthopedic devices, and other complex medical devices with lumens.
Optical and dark characterization of the PLATO CCD at ESA
NASA Astrophysics Data System (ADS)
Verhoeve, Peter; Prod'homme, Thibaut; Oosterbroek, Tim; Duvet, Ludovic; Beaufort, Thierry; Blommaert, Sander; Butler, Bart; Heijnen, Jerko; Lemmel, Frederic; van der Luijt, Cornelis; Smit, Hans; Visser, Ivo
2016-07-01
PLATO - PLAnetary Transits and Oscillations of stars - is the third medium-class mission (M3) to be selected in the European Space Agency (ESA) Science and Robotic Exploration Cosmic Vision programme. It is due for launch in 2025 with the main objective to find and study terrestrial planets in the habitable zone around solar-like stars. The payload consists of >20 cameras; with each camera comprising 4 Charge-Coupled Devices (CCDs), a large number of flight model devices procured by ESA shall ultimately be integrated on the spacecraft. The CCD270 - specially designed and manufactured by e2v for the PLATO mission - is a large format (8 cm x 8 cm) back-illuminated device operating at 4 MHz pixel rate and coming in two variants: full frame and frame transfer. In order to de-risk the PLATO CCD procurement and aid the mission definition process, ESA's Payload Technology Validation section is currently validating the PLATO CCD270. This validation consists in demonstrating that the device achieves its specified electrooptical performance in the relevant environment: operated at 4 MHz, at cold and before and after proton irradiation. As part of this validation, CCD270 devices have been characterized in the dark as well as optically with respect to performance parameters directly relevant for the photometric application of the CCDs. Dark tests comprise the measurement of gain sensitivity to bias voltages, charge injection tests, and measurement of hot and variable pixels after irradiation. In addition, the results of measurements of Quantum Efficiency for a range of angles of incidence, intra- pixel response (non-)uniformity, and response to spot illumination, before and after proton irradiation. In particular, the effect of radiation induced degradation of the charge transfer efficiency on the measured charge in a star-like spot has been studied as a function of signal level and of position on the pixel grid, Also, the effect of various levels of background light on the amount of charge lost from a star image are described. These results can serve as a direct input to the PLATO consortium to study the mission performance and as a basis for further optimization of the CCD operation.
Microgravity Processing and Photonic Applications of Organic and Polymeric Materials
NASA Technical Reports Server (NTRS)
Frazier, Donald O.; Paley, Mark S.; Penn, Benjamin G.; Abdeldayem, Hossin A.; Smith, David D.; Witherow, William K.
1997-01-01
Some of the primary purposes of this work are to study important technologies, particularly involving thin films, relevant to organic and polymeric materials for improving applicability to optical circuitry and devices and to assess the contribution of convection on film quality in unit and microgravity environments. Among the most important materials processing techniques of interest in this work are solution-based and by physical vapor transport, both having proven gravitational and acceleration dependence. In particular, PolyDiAcetylenes (PDA's) and PhthaloCyanines (Pc's) are excellent NonLinear Optical (NLO) materials with the promise of significantly improved NLO properties through order and film quality enhancements possible through microgravity processing. Our approach is to focus research on integrated optical circuits and optoelectronic devices relevant to solution-based and vapor processes of interest in the Space Sciences Laboratory at the Marshall Space Flight Center (MSFC). Modification of organic materials is an important aspect of achieving more highly ordered structures in conjunction with microgravity processing. Parallel activities include characterization of materials for particular NLO properties and determination of appropriation device designs consistent with selected applications. One result of this work is the determination, theoretically, that buoyancy-driven convection occurs at low pressures in an ideal gas in a thermalgradient from source to sink. Subsequent experiment supports the theory. We have also determined theoretically that buoyancy-driven convection occurs during photodeposition of PDA, an MSFC-patented process for fabricating complex circuits, which is also supported by experiment. Finally, the discovery of intrinsic optical bistability in metal-free Pc films enables the possibility of the development of logic gate technology on the basis of these materials.
Cryotherapy Treatment After Unicompartmental and Total Knee Arthroplasty: A Review.
Chughtai, Morad; Sodhi, Nipun; Jawad, Michael; Newman, Jared M; Khlopas, Anton; Bhave, Anil; Mont, Michael A
2017-12-01
Cryotherapy is widely utilized to enhance recovery after knee surgeries. However, the outcome parameters often vary between studies. Therefore, the purpose of this review is to compare (1) no cryotherapy vs cryotherapy; (2) cold pack cryotherapy vs continuous flow device cryotherapy; (3) various protocols of application of these cryotherapy methods; and (4) cost-benefit analysis in patients who had unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). A search for "knee" and "cryotherapy" using PubMed, EBSCO Host, and SCOPUS was performed, yielding 187 initial reports. After selecting for RCTs relevant to our study, 16 studies were included. Of the 8 studies that compared the immediate postoperative outcomes between patients who did and did not receive cryotherapy, 5 studies favored cryotherapy (2 cold packs and 3 continuous cold flow devices). Of the 6 studies comparing the use of cold packs and continuous cold flow devices in patients who underwent UKA or TKA, 3 favor the use of continuous flow devices. There was no difference in pain, postoperative opioid consumption, or drain output between 2 different temperature settings of continuous cold flow device. The optimal device to use may be one that offers continuous circulating cold flow, as there were more studies demonstrating better outcomes. In addition, the pain relieving effects of cryotherapy may help minimize pain medication use, such as with opioids, which are associated with numerous potential side effects as well as dependence and addiction. Meta-analysis on the most recent RCTs should be performed next. Copyright © 2017 Elsevier Inc. All rights reserved.
Nadalin, V; Marrett, L D; Cawley, C; Minaker, L M; Manske, S
2018-06-01
This report explores intentional tanning behaviors among Canadian high school students in light of provincial restrictions on UV tanning device use among youth. Data are from the Cancer Risk Assessment in Youth Survey (CRAYS), collected from January to December 2015, at randomly selected high schools in 7 provinces. Relevant variables were: tanning methods ever used, demographics, and location and refusal of UV tanning device (beds, lamps) use in the past 12 months. Data were weighted so total survey weights by male/female, grade and province equal actual enrolments in these groups. Analyses were conducted in SAS, mostly for grades 10 and 11. Rao-Scott chi squared tests and p-values were calculated. Among 6803 grade 10 and 11 participants, 82% tanned intentionally, mostly by being/playing outside, or laying in the sun. Spray/self-tanners were used by 15% of participants. UV tanning device use was uncommon (4.4%), lowest in Ontario (2.7%) and British Columbia (3.8%), which have legislation against use among youth. Of 202 who used UV tanning devices in the past 12 months, most did at salons/studios (85%), 35% at home and 30% at a gym. Two hundred and forty-nine participants (3.4%) were refused use of UV tanning devices in the past 12 months. While legislation appears to deter UV tanning device use, it appears to have no impact on UV exposure among high school students overall. Greater prevention efforts are required to deter intentional tanning among high school students. Copyright © 2018 Elsevier Inc. All rights reserved.
Relevant, irredundant feature selection and noisy example elimination.
Lashkia, George V; Anthony, Laurence
2004-04-01
In many real-world situations, the method for computing the desired output from a set of inputs is unknown. One strategy for solving these types of problems is to learn the input-output functionality from examples in a training set. However, in many situations it is difficult to know what information is relevant to the task at hand. Subsequently, researchers have investigated ways to deal with the so-called problem of consistency of attributes, i.e., attributes that can distinguish examples from different classes. In this paper, we first prove that the notion of relevance of attributes is directly related to the consistency of attributes, and show how relevant, irredundant attributes can be selected. We then compare different relevant attribute selection algorithms, and show the superiority of algorithms that select irredundant attributes over those that select relevant attributes. We also show that searching for an "optimal" subset of attributes, which is considered to be the main purpose of attribute selection, is not the best way to improve the accuracy of classifiers. Employing sets of relevant, irredundant attributes improves classification accuracy in many more cases. Finally, we propose a new method for selecting relevant examples, which is based on filtering the so-called pattern frequency domain. By identifying examples that are nontypical in the determination of relevant, irredundant attributes, irrelevant examples can be eliminated prior to the learning process. Empirical results using artificial and real databases show the effectiveness of the proposed method in selecting relevant examples leading to improved performance even on greatly reduced training sets.
Method and system for reducing device performance degradation of organic devices
Teague, Lucile C.
2014-09-02
Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.
Modelling toolkit for simulation of maglev devices
NASA Astrophysics Data System (ADS)
Peña-Roche, J.; Badía-Majós, A.
2017-01-01
A stand-alone App1 has been developed, focused on obtaining information about relevant engineering properties of magnetic levitation systems. Our modelling toolkit provides real time simulations of 2D magneto-mechanical quantities for superconductor (SC)/permanent magnet structures. The source code is open and may be customised for a variety of configurations. Ultimately, it relies on the variational statement of the critical state model for the superconducting component and has been verified against experimental data for YBaCuO/NdFeB assemblies. On a quantitative basis, the values of the arising forces, induced superconducting currents, as well as a plot of the magnetic field lines are displayed upon selection of an arbitrary trajectory of the magnet in the vicinity of the SC. The stability issues related to the cooling process, as well as the maximum attainable forces for a given material and geometry are immediately observed. Due to the complexity of the problem, a strategy based on cluster computing, database compression, and real-time post-processing on the device has been implemented.
Setting Standards for Reporting and Quantification in Fluorescence-Guided Surgery.
Hoogstins, Charlotte; Burggraaf, Jan Jaap; Koller, Marjory; Handgraaf, Henricus; Boogerd, Leonora; van Dam, Gooitzen; Vahrmeijer, Alexander; Burggraaf, Jacobus
2018-05-29
Intraoperative fluorescence imaging (FI) is a promising technique that could potentially guide oncologic surgeons toward more radical resections and thus improve clinical outcome. Despite the increase in the number of clinical trials, fluorescent agents and imaging systems for intraoperative FI, a standardized approach for imaging system performance assessment and post-acquisition image analysis is currently unavailable. We conducted a systematic, controlled comparison between two commercially available imaging systems using a novel calibration device for FI systems and various fluorescent agents. In addition, we analyzed fluorescence images from previous studies to evaluate signal-to-background ratio (SBR) and determinants of SBR. Using the calibration device, imaging system performance could be quantified and compared, exposing relevant differences in sensitivity. Image analysis demonstrated a profound influence of background noise and the selection of the background on SBR. In this article, we suggest clear approaches for the quantification of imaging system performance assessment and post-acquisition image analysis, attempting to set new standards in the field of FI.
Teipel, Stefan; König, Alexandra; Hoey, Jesse; Kaye, Jeff; Krüger, Frank; Robillard, Julie M; Kirste, Thomas; Babiloni, Claudio
2018-06-21
Cognitive function is an important end point of treatments in dementia clinical trials. Measuring cognitive function by standardized tests, however, is biased toward highly constrained environments (such as hospitals) in selected samples. Patient-powered real-world evidence using information and communication technology devices, including environmental and wearable sensors, may help to overcome these limitations. This position paper describes current and novel information and communication technology devices and algorithms to monitor behavior and function in people with prodromal and manifest stages of dementia continuously, and discusses clinical, technological, ethical, regulatory, and user-centered requirements for collecting real-world evidence in future randomized controlled trials. Challenges of data safety, quality, and privacy and regulatory requirements need to be addressed by future smart sensor technologies. When these requirements are satisfied, these technologies will provide access to truly user relevant outcomes and broader cohorts of participants than currently sampled in clinical trials. Copyright © 2018. Published by Elsevier Inc.
The role of visual deprivation and experience on the performance of sensory substitution devices.
Stronks, H Christiaan; Nau, Amy C; Ibbotson, Michael R; Barnes, Nick
2015-10-22
It is commonly accepted that the blind can partially compensate for their loss of vision by developing enhanced abilities with their remaining senses. This visual compensation may be related to the fact that blind people rely on their other senses in everyday life. Many studies have indeed shown that experience plays an important role in visual compensation. Numerous neuroimaging studies have shown that the visual cortices of the blind are recruited by other functional brain areas and can become responsive to tactile or auditory input instead. These cross-modal plastic changes are more pronounced in the early blind compared to late blind individuals. The functional consequences of cross-modal plasticity on visual compensation in the blind are debated, as are the influences of various etiologies of vision loss (i.e., blindness acquired early or late in life). Distinguishing between the influences of experience and visual deprivation on compensation is especially relevant for rehabilitation of the blind with sensory substitution devices. The BrainPort artificial vision device and The vOICe are assistive devices for the blind that redirect visual information to another intact sensory system. Establishing how experience and different etiologies of vision loss affect the performance of these devices may help to improve existing rehabilitation strategies, formulate effective selection criteria and develop prognostic measures. In this review we will discuss studies that investigated the influence of training and visual deprivation on the performance of various sensory substitution approaches. Copyright © 2015 Elsevier B.V. All rights reserved.
Brunet, J; Pauly, A; Dubois, M; Rodriguez-Mendez, M L; Ndiaye, A L; Varenne, C; Guérin, K
2014-09-01
A new and original gas sensor-system dedicated to the selective monitoring of nitrogen dioxide in air and in the presence of ozone, has been successfully achieved. Because of its high sensitivity and its partial selectivity towards oxidizing pollutants (nitrogen dioxide and ozone), copper phthalocyanine-based chemoresistors are relevant. The selectivity towards nitrogen dioxide results from the implementation of a high efficient and selective ozone filter upstream the sensing device. Thus, a powdered indigo/nanocarbons hybrid material has been developed and investigated for such an application. If nanocarbonaceous material acts as a highly permeable matrix with a high specific surface area, immobilized indigo nanoparticles are involved into an ozonolysis reaction with ozone leading to the selective removal of this analytes from air sample. The filtering yields towards each gas have been experimentally quantified and establish the complete removal of ozone while having the concentration of nitrogen dioxide unchanged. Long-term gas exposures reveal the higher durability of hybrid material as compared to nanocarbons and indigo separately. Synthesis, characterizations by many complementary techniques and tests of hybrid filters are detailed. Results on sensor-system including CuPc-based chemoresistors and indigo/carbon nanotubes hybrid material as in-line filter are illustrated. Sensing performances will be especially discussed. Copyright © 2014 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
...; formerly Docket No. 2007D-0290] Draft Guidance for Industry: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral Blood Stem Cells; Withdrawal of Draft Guidance...: Cell Selection Devices for Point of Care Production of Minimally Manipulated Autologous Peripheral...
Oculomotor selection underlies feature retention in visual working memory.
Hanning, Nina M; Jonikaitis, Donatas; Deubel, Heiner; Szinte, Martin
2016-02-01
Oculomotor selection, spatial task relevance, and visual working memory (WM) are described as three processes highly intertwined and sustained by similar cortical structures. However, because task-relevant locations always constitute potential saccade targets, no study so far has been able to distinguish between oculomotor selection and spatial task relevance. We designed an experiment that allowed us to dissociate in humans the contribution of task relevance, oculomotor selection, and oculomotor execution to the retention of feature representations in WM. We report that task relevance and oculomotor selection lead to dissociable effects on feature WM maintenance. In a first task, in which an object's location was encoded as a saccade target, its feature representations were successfully maintained in WM, whereas they declined at nonsaccade target locations. Likewise, we observed a similar WM benefit at the target of saccades that were prepared but never executed. In a second task, when an object's location was marked as task relevant but constituted a nonsaccade target (a location to avoid), feature representations maintained at that location did not benefit. Combined, our results demonstrate that oculomotor selection is consistently associated with WM, whereas task relevance is not. This provides evidence for an overlapping circuitry serving saccade target selection and feature-based WM that can be dissociated from processes encoding task-relevant locations. Copyright © 2016 the American Physiological Society.
[Harm related to medical device use - legal and organisational risks].
Hölscher, U M
2014-12-01
The effectiveness of the risk management systems established by medical device manufacturers and health-care facilities is clearly mitigated by European and national legal provisions. Laws, regulations and authorities prevent the systematic exchange of much safety-relevant information. The obligation to report adverse events is suspended for many relevant risks associated with medical device use. Reporting into the vigilance system is of little avail for users. Reporting even may endanger the information provider. The federal fragmentation of the German vigilance system poses a risk for patients. Risk management in health-care facilities without risk policy is dangerously incomplete. © Georg Thieme Verlag KG Stuttgart · New York.
Silk-polypyrrole biocompatible actuator performance under biologically relevant conditions
NASA Astrophysics Data System (ADS)
Hagler, Jo'elen; Peterson, Ben; Murphy, Amanda; Leger, Janelle
Biocompatible actuators that are capable of controlled movement and can function under biologically relevant conditions are of significant interest in biomedical fields. Previously, we have demonstrated that a composite material of silk biopolymer and the conducting polymer polypyrrole (PPy) can be formed into a bilayer device that can bend under applied voltage. Further, these silk-PPy composites can generate forces comparable to human muscle (>0.1 MPa) making them ideal candidates for interfacing with biological tissues. Here silk-PPy composite films are tested for performance under biologically relevant conditions including exposure to a complex protein serum and biologically relevant temperatures. Free-end bending actuation performance, current response, force generation and, mass degradation were investigated . Preliminary results show that when exposed to proteins and biologically relevant temperatures, these silk-PPy composites show minimal degradation and are able to generate forces and conduct currents comparable to devices tested under standard conditions. NSF.
2014-01-01
Background According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). Methods The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. Results The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. Conclusions The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a standards-compliant development of small and medium-sized medical software can be carried out by a small team with limited resources in a clinical setting. This is of particular relevance as the upcoming revision of the Medical Device Directive is expected to harmonize and tighten the current legal requirements for all European in-house manufacturers. PMID:24655818
Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver
2014-03-21
According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a standards-compliant development of small and medium-sized medical software can be carried out by a small team with limited resources in a clinical setting. This is of particular relevance as the upcoming revision of the Medical Device Directive is expected to harmonize and tighten the current legal requirements for all European in-house manufacturers.
NASA Astrophysics Data System (ADS)
Zabasta, A.; Kunicina, N.; Kondratjevs, K.
2017-06-01
Collaboration between heterogeneous systems and architectures is not an easy problem in the automation domain. By now, utilities and suppliers encounter real problems due to underestimated costs of technical solutions, frustration in selecting technical solutions relevant for local needs, and incompatibilities between a plenty of protocols and appropriate solutions. The paper presents research on creation of architecture of smart municipal systems in a local cloud of services that apply SOA and IoT approaches. The authors of the paper have developed a broker that applies orchestration services and resides on a gateway, which provides adapter and protocol translation functions, as well as applies a tool for wiring together hardware devices, APIs and online services.
Long-term Spatial Distribution Patterns of Protozoa in Connected Microhabitats
NASA Astrophysics Data System (ADS)
Taghon, G. L.; Tuorto, S. J.
2016-02-01
Studies of microbial ecosystems usually assume habitat homogeneity. Recent research, however, indicates that habitat structure varies at millimeter scales and that this patchiness affects abundance and behavior of microbes. In this study, two species of ciliated protozoa were maintained, together, for multiple generations in microfluidic devices consisting of arrays of interconnected microhabitats with differing resource availability. The species differed in their population dynamics and tendency to disperse among microhabitats. Both species coexisted for over 45 days, and their coexistence likely resulted from habitat selection at millimeter scales. We demonstrate that it is not only possible, but imperative, that detailed ecological phenomena of microbial systems be studied at the relevant spatial and temporal scales.
"Just Remember This": Lexicogrammatical Relevance Markers in Lectures
ERIC Educational Resources Information Center
Deroey, Katrien L. B.; Taverniers, Miriam
2012-01-01
This paper presents a comprehensive overview of lexicogrammatical devices which highlight important or relevant points in lectures. Despite the established usefulness of discourse organizational cues for lecture comprehension and note-taking, very little is known about the marking of relevance in this genre. The current overview of…
Determination of Altitude Sickness Risk (DASR) User’s Guide for Apple Mobile Devices
2015-06-01
Android Smartphone Relevance to Military Weather Applications”.2 2. DASR Inputs To launch DASR, simply tap the DASR icon on the device start screen...risk due to sleep deprivation). TB MED 505 should be consulted for additional details if necessary. 5 Fig. 4 Individual Factors view The risk...armypubs.army.mil/med/index.html]. 2. Sauter, D. Android smartphone relevance to military weather applications. White Sands Missile Range (NM); Army Research
Material selection indices for design of surgical instruments with long tubular shafts.
Nelson, Carl A
2013-02-01
In any medical device design process, material selection plays an important role. For devices which sustain mechanical loading, strength and stiffness requirements can be significant drivers of the design. This paper examines the specific case of minimally invasive surgical instruments, including robotic instruments, having long, tubular shafts. Material properties-based selection indices are derived for achieving high performance of these devices in terms of strength and stiffness, and the use of these indices for informing the medical device design problem is illustrated.
Clinical efficacy and effectiveness of 3D printing: a systematic review
Diment, Laura E; Thompson, Mark S; Bergmann, Jeroen H M
2017-01-01
Objective To evaluate the clinical efficacy and effectiveness of using 3D printing to develop medical devices across all medical fields. Design Systematic review compliant with Preferred Reporting Items for Systematic Reviews and Meta-Analyses. Data sources PubMed, Web of Science, OVID, IEEE Xplore and Google Scholar. Methods A double-blinded review method was used to select all abstracts up to January 2017 that reported on clinical trials of a three-dimensional (3D)-printed medical device. The studies were ranked according to their level of evidence, divided into medical fields based on the International Classification of Diseases chapter divisions and categorised into whether they were used for preoperative planning, aiding surgery or therapy. The Downs and Black Quality Index critical appraisal tool was used to assess the quality of reporting, external validity, risk of bias, risk of confounding and power of each study. Results Of the 3084 abstracts screened, 350 studies met the inclusion criteria. Oral and maxillofacial surgery contained 58.3% of studies, and 23.7% covered the musculoskeletal system. Only 21 studies were randomised controlled trials (RCTs), and all fitted within these two fields. The majority of RCTs were 3D-printed anatomical models for preoperative planning and guides for aiding surgery. The main benefits of these devices were decreased surgical operation times and increased surgical accuracy. Conclusions All medical fields that assessed 3D-printed devices concluded that they were clinically effective. The fields that most rigorously assessed 3D-printed devices were oral and maxillofacial surgery and the musculoskeletal system, both of which concluded that the 3D-printed devices outperformed their conventional comparators. However, the efficacy and effectiveness of 3D-printed devices remain undetermined for the majority of medical fields. 3D-printed devices can play an important role in healthcare, but more rigorous and long-term assessments are needed to determine if 3D-printed devices are clinically relevant before they become part of standard clinical practice. PMID:29273650
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolenbaugh, Jonathan M.; Naqi, Syed
A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to entermore » the flow control device to activate the clutch device.« less
TAXONOMY OF MEDICAL DEVICES IN THE LOGIC OF HEALTH TECHNOLOGY ASSESSMENT.
Henschke, Cornelia; Panteli, Dimitra; Perleth, Matthias; Busse, Reinhard
2015-01-01
The suitability of general HTA methodology for medical devices is gaining interest as a topic of scientific discourse. Given the broad range of medical devices, there might be differences between groups of devices that impact both the necessity and the methods of their assessment. Our aim is to develop a taxonomy that provides researchers and policy makers with an orientation tool on how to approach the assessment of different types of medical devices. Several classifications for medical devices based on varying rationales for different regulatory and reporting purposes were analyzed in detail to develop a comprehensive taxonomic model. The taxonomy is based on relevant aspects of existing classification schemes incorporating elements of risk and functionality. Its 9 × 6 matrix distinguishes between the diagnostic or therapeutic nature of devices and considers whether the medical device is directly used by patients, constitutes part of a specific procedure, or can be used for a variety of procedures. We considered the relevance of different device categories in regard to HTA to be considerably variable, ranging from high to low. Existing medical device classifications cannot be used for HTA as they are based on different underlying logics. The developed taxonomy combines different device classification schemes used for different purposes. It aims at providing decision makers with a tool enabling them to consider device characteristics in detail across more than one dimension. The placement of device groups in the matrix can provide decision support on the necessity of conducting a full HTA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, Peter M.
Executive Summary In conjunction with the Brown Energy Initiative, research Projects selected for the fuel cell research grant were selected on the following criteria: They should be fundamental research that has the potential to significantly impact the nation’s energy infrastructure. They should be scientifically exciting and sound. They should synthesize new materials, lead to greater insights, explore new phenomena, or design new devices or processes that are of relevance to solving the energy problems. They involve top-caliper senior scientists with a record of accomplishment, or junior faculty with outstanding promise of achievement. They should promise to yield at least preliminarymore » results within the given funding period, which would warrant further research development. They should fit into the overall mission of the Brown Energy Initiative, and the investigators should contribute as partners to an intellectually stimulating environment focused on energy science. Based on these criteria, fourteen faculty across three disciplines (Chemistry, Physics and Engineering) and the Charles Stark Draper Laboratory were selected to participate in this effort.1 In total, there were 30 people supported, at some level, on these projects. This report highlights the findings and research outcomes of the participating researchers.« less
A printed electronic platform for the specific detection of biomolecules
NASA Astrophysics Data System (ADS)
Doumbia, A.; Webb, M.; Turner, M. L.; Behrendt, J. M.; Wilson, R.
2017-08-01
The rapid detection of disease specific biomarkers in a clinically relevant range using a low-cost sensor can facilitate the development of individual treatment plans for a given patient, known as precision, personalized or genomic medicine. In the recent decade Electrolyte-Gated Organic Field Effect Transistors (EGOFETs), a subtype of OFETs where the dielectric is replaced by an electrolyte, have attracted a great deal of attention for sensing applications. This is due to their capacity to operate at low voltage (< 1 volt) in physiological like media. Although EGOFET based biosensors have been shown to specifically detect biomolecules with high sensitivity and selectivity; the stability, reproducibility, and performance required to reach the desired market are not yet achieved. In this contribution, we describe the development of a stable and reproducible EGOFET sensor that is able to detect biomolecules selectively in real-time. Facile and scalable techniques are used to prepare arrays of these devices. The selectivity of individual EGOFETs is investigated by immobilization of specific ligands to the target molecule of interest on the gate electrode within a microfluidic flow cell.
Communicating with residential electrical devices via a vehicle telematics unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, Rebecca C.; Pebbles, Paul H.
A method of communicating with residential electrical devices using a vehicle telematics unit includes receiving information identifying a residential electrical device to control; displaying in a vehicle one or more controlled features of the identified residential electrical device; receiving from a vehicle occupant a selection of the displayed controlled features of the residential electrical device; sending an instruction from the vehicle telematics unit to the residential electrical device via a wireless carrier system in response to the received selection; and controlling the residential electrical device using the sent instruction.
Wang, Lusheng; Wang, Yamei; Ding, Zhizhong; Wang, Xiumin
2015-09-18
With the rapid development of wireless networking technologies, the Internet of Things and heterogeneous cellular networks (HCNs) tend to be integrated to form a promising wireless network paradigm for 5G. Hyper-dense sensor and mobile devices will be deployed under the coverage of heterogeneous cells, so that each of them could freely select any available cell covering it and compete for resource with others selecting the same cell, forming a cell selection (CS) game between these devices. Since different types of cells usually share the same portion of the spectrum, devices selecting overlapped cells can experience severe inter-cell interference (ICI). In this article, we study the CS game among a large amount of densely-deployed sensor and mobile devices for their uplink transmissions in a two-tier HCN. ICI is embedded with the traditional congestion game (TCG), forming a congestion game with ICI (CGI) and a congestion game with capacity (CGC). For the three games above, we theoretically find the circular boundaries between the devices selecting the macrocell and those selecting the picocells, indicated by the pure strategy Nash equilibria (PSNE). Meanwhile, through a number of simulations with different picocell radii and different path loss exponents, the collapse of the PSNE impacted by severe ICI (i.e., a large number of picocell devices change their CS preferences to the macrocell) is profoundly revealed, and the collapse points are identified.
Wang, Lusheng; Wang, Yamei; Ding, Zhizhong; Wang, Xiumin
2015-01-01
With the rapid development of wireless networking technologies, the Internet of Things and heterogeneous cellular networks (HCNs) tend to be integrated to form a promising wireless network paradigm for 5G. Hyper-dense sensor and mobile devices will be deployed under the coverage of heterogeneous cells, so that each of them could freely select any available cell covering it and compete for resource with others selecting the same cell, forming a cell selection (CS) game between these devices. Since different types of cells usually share the same portion of the spectrum, devices selecting overlapped cells can experience severe inter-cell interference (ICI). In this article, we study the CS game among a large amount of densely-deployed sensor and mobile devices for their uplink transmissions in a two-tier HCN. ICI is embedded with the traditional congestion game (TCG), forming a congestion game with ICI (CGI) and a congestion game with capacity (CGC). For the three games above, we theoretically find the circular boundaries between the devices selecting the macrocell and those selecting the picocells, indicated by the pure strategy Nash equilibria (PSNE). Meanwhile, through a number of simulations with different picocell radii and different path loss exponents, the collapse of the PSNE impacted by severe ICI (i.e., a large number of picocell devices change their CS preferences to the macrocell) is profoundly revealed, and the collapse points are identified. PMID:26393617
SCHeMA open and modular in situ sensing solution
NASA Astrophysics Data System (ADS)
Tercier-Waeber, Marie Louise; Novellino, Antonio
2017-04-01
Marine environments are highly vulnerable and influenced by a wide diversity of anthropogenic and natural substances and organisms that may have adverse effects on the ecosystem equilibrium, on living resources and, ultimately, on human health. Identification of relevant types of hazards at the appropriate temporal and spatial scale is crucial to detect their sources and origin, to understand the processes governing their magnitude and distribution, and to ultimately evaluate and manage their risks and consequences preventing economic losses. This can be addressed only by the development of innovative, compact, rugged, automated, sensor networks allowing long-term monitoring. Development of such tools is a challenging task as it requires many analytical and technical innovations. The FP7-OCEAN 2013-SCHeMA project aims to contribute to meet this challenge by providing an open and modular sensing solution for autonomous in situ high resolution mapping of a range of anthropogenic and natural chemical compounds (trace metals, nutrients, anthropogenic organic compounds, toxic algae species and toxins, species relevant to the carbon cycle). To achieve this, SCHeMA activities focus on the development of : 1) an array of miniature sensor probes taking advantage of various innovative solutions, namely: (polymer-based) gel-integrated sensors; solid state ion-selective membrane sensors coupled to an on-line desalination module; mid-infrared optical sensors; optochemical multichannel devices; enOcean technology; 2) dedicated hardware, firmware and software components allowing their plug-and-play integration, localization as well as wireless bidirectional communication via advanced OGC-SWE wired/wireless dedicated interfaces; 3) a web-based front-end system compatible with EU standard requirements and principles (INSPIRE, GEO/GEOSS) and configured to insure easy interoperability with national, regional and local marine observation systems. This lecture will present examples of innovative approaches and devices successfully developed and currently explored. Potentiality of the SCHeMA individual probes and integrated system to provide new type of high-resolution environmental data will be illustrated by examples of field application in selected coastal areas. www.schema-ocean.eu
A Meta-Analysis of the Effect of Preoperative Biliary Stenting on Patients With Obstructive Jaundice
Sun, Chengyi; Yan, Guirong; Li, Zhiming; Tzeng, Chi-Meng
2014-01-01
Abstract The goal of this study was to systematically review the effects of biliary stenting on postoperative morbidity and mortality of patients with obstructive jaundice. PubMed, Embase, Cochrane Library, and other relevant databases were searched by computer and manually for published and unpublished studies on the impact of preoperative biliary drainage on patients with obstructive jaundice from 2000 to the present day. Two investigators independently selected the studies according to the inclusion and exclusion criteria, extracted the data, and assessed the quality of the selected studies. Meta-analysis was performed to compare postoperative morbidity and mortality of patients between the drainage and nondrainage groups. Compared with the nondrainage group, the overall mortality, overall morbidity, infectious morbidity, incidence of wound infection, intra-abdominal abscess, pancreatic fistulas, bile leak, and delayed gastric emptying in the drainage group were not significantly different. Compared with the nondrainage group, the drainage group had a drainage time of <4 weeks with an increased overall morbidity by 7% to 23%; however, the overall morbidity of the drainage group with a drainage time >4 weeks was not significantly different. Compared with the nondrainage group, the overall mortality of the drainage group using metal stents and plastic stents as internal drainage devices was reduced by 0.5% to 6%, whereas that of the drainage group using plastic stent devices was not significantly different. In summary, preoperative drainage should be applied selectively. The drainage time should be >4 weeks, and metal stents should be used for internal drainage. PMID:25474436
IDEA. VOCES: A Mnemonic Device to Cue Mood Selection after Impersonal Expressions.
ERIC Educational Resources Information Center
Chandler, Paul Michael
1996-01-01
Providing language learners with mnemonic devices assists retention and recall of vocabulary and structural items. This idea provides one such memory device to assist beginning and intermediate students who struggle with mood selection after impersonal expressions. (five references) (Author)
Zone routing in a torus network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dong; Heidelberger, Philip; Kumar, Sameer
A system for routing data in a network comprising a network logic device at a sending node for determining a path between the sending node and a receiving node, wherein the network logic device sets one or more selection bits and one or more hint bits within the data packet, a control register for storing one or more masks, wherein the network logic device uses the one or more selection bits to select a mask from the control register and the network logic device applies the selected mask to the hint bits to restrict routing of the data packet tomore » one or more routing directions for the data packet within the network and selects one of the restricted routing directions from the one or more routing directions and sends the data packet along a link in the selected routing direction toward the receiving node.« less
Apparatus and method for evaporator defrosting
Mei, Viung C.; Chen, Fang C.; Domitrovic, Ronald E.
2001-01-01
An apparatus and method for warm-liquid defrosting of the evaporator of a refrigeration system. The apparatus includes a first refrigerant expansion device that selectively expands refrigerant for cooling the evaporator, a second refrigerant expansion device that selectively expands the refrigerant after the refrigerant has passed through the evaporator, and a defrosting control for the first refrigerant expansion device and second refrigerant expansion device to selectively defrost the evaporator by causing warm refrigerant to flow through the evaporator. The apparatus is alternately embodied with a first refrigerant bypass and/or a second refrigerant bypass for selectively directing refrigerant to respectively bypass the first refrigerant expansion device and the second refrigerant expansion device, and with the defrosting control connected to the first refrigerant bypass and/or the second refrigerant bypass to selectively activate and deactivate the bypasses depending upon the current cycle of the refrigeration system. The apparatus alternately includes an accumulator for accumulating liquid and/or gaseous refrigerant that is then pumped either to a refrigerant receiver or the first refrigerant expansion device for enhanced evaporator defrosting capability. The inventive method of defrosting an evaporator in a refrigeration system includes the steps of compressing refrigerant in a compressor and cooling the refrigerant in the condenser such that the refrigerant is substantially in liquid form, passing the refrigerant substantially in liquid form through the evaporator, and expanding the refrigerant with a refrigerant expansion device after the refrigerant substantially passes through the evaporator.
Quantum well infrared photodetectors (QWIP) with selectively regrown N-GaAs plugs
NASA Astrophysics Data System (ADS)
Matsukura, Yusuke; Nishino, Hironori; Tanaka, Hitoshi; Fujii, Toshio
2001-10-01
We fabricated the GaAs/AlGaAs Quantum Well Infrared Photo detector (QWIP) focal plane array with selectively re-grown N- GaAs interconnection plugs and demonstrated its device operation, in order to establish the technology to obtain both complex device functions and device manufacturability. MBE (Molecular Beam Epitaxy) grown QWIP MQW wafers were covered with SiON and SiNx mask films to obtain selectivity of the re-growth process. N-GaAs plugs were re-grown selectively with low-pressure MOCVD (Metal-Organic Chemical Vapor Deposition) with AsH3 and Dimethylgalliumchloride as precursors, only on the bottom surfaces of the holes for the interconnection to extract the electrodes from the underlying epilayer. Cross- sectional SEM observation revealed that the feature of the re- grown N-GaAs plugs was triangular, rather than rectangular as expected. The reason for this discrepancy is not yet clear. The electrical contact between the epilayer and re-grown N- GaAs plug was 'ohmic-like,' without any trace of interfacial barrier. The Current-Voltage characteristics of the fabricated QWIP device showed no tangible leakage current between the N- GaAs plug and device structure, indicating that electrical insulation between the N-GaAs plugs and device structure was sufficient. Fabricated devices were successfully operated as a hybrid focal plane array, indicating the selective re-growth was a promising technique to realize complex QWIP based devices.
Holanda, Ledycnarf J; Silva, Patrícia M M; Amorim, Thiago C; Lacerda, Matheus O; Simão, Camila R; Morya, Edgard
2017-12-04
Spinal cord injury (SCI) is characterized by a total or partial deficit of sensory and motor pathways. Impairments of this injury compromise muscle recruitment and motor planning, thus reducing functional capacity. SCI patients commonly present psychological, intestinal, urinary, osteomioarticular, tegumentary, cardiorespiratory and neural alterations that aggravate in chronic phase. One of the neurorehabilitation goals is the restoration of these abilities by favoring improvement in the quality of life and functional independence. Current literature highlights several benefits of robotic gait therapies in SCI individuals. The purpose of this study was to compare the robotic gait devices, and systematize the scientific evidences of these devices as a tool for rehabilitation of SCI individuals. A systematic review was carried out in which relevant articles were identified by searching the following databases: Cochrane Library, PubMed, PEDro and Capes Periodic. Two authors selected the articles which used a robotic device for rehabilitation of spinal cord injury. Databases search found 2941 articles, 39 articles were included due to meet the inclusion criteria. The robotic devices presented distinct features, with increasing application in the last years. Studies have shown promising results regarding the reduction of pain perception and spasticity level; alteration of the proprioceptive capacity, sensitivity to temperature, vibration, pressure, reflex behavior, electrical activity at muscular and cortical level, classification of the injury level; increase in walking speed, step length and distance traveled; improvements in sitting posture, intestinal, cardiorespiratory, metabolic, tegmental and psychological functions. This systematic review shows a significant progress encompassing robotic devices as an innovative and effective therapy for the rehabilitation of individuals with SCI.
Exploring e-readers to support clinical medical education: two case studies*†
von Isenburg, Megan
2011-01-01
Question: Can e-readers loaded with medical textbooks and other relevant material benefit medical students, residents, and preceptors in clinical settings? Settings: The settings are North Carolina community clinics served by Duke University Medical Center and St. Joseph's Hospital in Bryan, Texas, and Scott and White Memorial Hospital in Temple, Texas. Methods: Duke University: Twenty second-year medical students and fourteen family medicine clerkship preceptors used Kindle e-readers in clinics during eight months of rotations. Students and preceptors provided feedback through an anonymous online survey. Texas A&M University: Nine fourth-year medical students in an elective compared medical textbooks in print, online, and on a Kindle. Six residents at a local hospital completed an anonymous online survey after a three-week loan of a Kindle loaded with medical textbooks. Results: The e-reader's major advantages in clinical settings are portability and searchability. The selected e-reader's limitations include connection speed, navigation, and display. User preferences varied, but online resources were preferred. Participants suggested additional uses for Kindles in medical education. Conclusions: The selected e-reader's limitations may be resolved with further development of the device. Investigation of other e-readers is needed. Criteria for evaluating e-readers in clinical settings should include portability, searchability, speed, navigation, and display. Research comparing e-readers and mobile devices in clinical education is also warranted. PMID:21464848
Desveaux, Laura; Gagliardi, Anna R
2018-06-04
Post-market surveillance of medical devices is reliant on physician reporting of adverse medical device events (AMDEs). Few studies have examined factors that influence whether and how physicians report AMDEs, an essential step in the development of behaviour change interventions. This study was a secondary analysis comparing application of the Theoretical Domains Framework (TDF) and the Tailored Implementation for Chronic Diseases (TICD) framework to identify potential behaviour change interventions that correspond to determinants of AMDE reporting. A previous study involving qualitative interviews with Canadian physicians that implant medical devices identified themes reflecting AMDE reporting determinants. In this secondary analysis, themes that emerged from the primary analysis were independently mapped to the TDF and TICD. Determinants and corresponding intervention options arising from both frameworks (and both mappers) were compared. Both theoretical frameworks were useful for identifying interventions corresponding to behavioural determinants of AMDE reporting. Information or education strategies that provide evidence about AMDEs, and audit and feedback of AMDE data were identified as interventions to target the theme of physician beliefs; improving information systems, and reminder cues, prompts and awards were identified as interventions to address determinants arising from the organization or systems themes; and modifying financial/non-financial incentives and sharing data on outcomes associated with AMDEs were identified as interventions to target device market themes. Numerous operational challenges were encountered in the application of both frameworks including a lack of clarity about how directly relevant to themes the domains/determinants should be, how many domains/determinants to select, if and how to resolve discrepancies across multiple mappers, and how to choose interventions from among the large number associated with selected domains/determinants. Given discrepancies in mapping themes to determinants/domains and the resulting interventions offered by the two frameworks, uncertainty remains about how to choose interventions that best match behavioural determinants in a given context. Further research is needed to provide more nuanced guidance on the application of TDF and TICD for a broader audience, which is likely to increase the utility and uptake of these frameworks in practice.
Bell nonlocality: a resource for device-independent quantum information protocols
NASA Astrophysics Data System (ADS)
Acin, Antonio
2015-05-01
Bell nonlocality is not only one of the most fundamental properties of quantum physics, but has also recently acquired the status of an information resource for device-independent quantum information protocols. In the device-independent approach, protocols are designed so that their performance is independent of the internal working of the devices used in the implementation. We discuss all these ideas and argue that device-independent protocols are especially relevant or cryptographic applications, as they are insensitive to hacking attacks exploiting imperfections on the modelling of the devices.
Understanding Monitoring Technologies for Adults With Pain: Systematic Literature Review.
Rodríguez, Iyubanit; Herskovic, Valeria; Gerea, Carmen; Fuentes, Carolina; Rossel, Pedro O; Marques, Maíra; Campos, Mauricio
2017-10-27
Monitoring of patients may decrease treatment costs and improve quality of care. Pain is the most common health problem that people seek help for in hospitals. Therefore, monitoring patients with pain may have significant impact in improving treatment. Several studies have studied factors affecting pain; however, no previous study has reviewed the contextual information that a monitoring system may capture to characterize a patient's situation. The objective of this study was to conduct a systematic review to (1) determine what types of technologies have been used to monitor adults with pain, and (2) construct a model of the context information that may be used to implement apps and devices aimed at monitoring adults with pain. A literature search (2005-2015) was conducted in electronic databases pertaining to medical and computer science literature (PubMed, Science Direct, ACM Digital Library, and IEEE Xplore) using a defined search string. Article selection was done through a process of removing duplicates, analyzing title and abstract, and then reviewing the full text of the article. In the final analysis, 87 articles were included and 53 of them (61%) used technologies to collect contextual information. A total of 49 types of context information were found and a five-dimension (activity, identity, wellness, environment, physiological) model of context information to monitor adults with pain was proposed, expanding on a previous model. Most technological interfaces for pain monitoring were wearable, possibly because they can be used in more realistic contexts. Few studies focused on older adults, creating a relevant avenue of research on how to create devices for users that may have impaired cognitive skills or low digital literacy. The design of monitoring devices and interfaces for adults with pain must deal with the challenge of selecting relevant contextual information to understand the user's situation, and not overburdening or inconveniencing users with information requests. A model of contextual information may be used by researchers to choose possible contextual information that may be monitored during studies on adults with pain. ©Iyubanit Rodríguez, Valeria Herskovic, Carmen Gerea, Carolina Fuentes, Pedro O Rossel, Maíra Marques, Mauricio Campos. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 27.10.2017.
Active space debris removal—A preliminary mission analysis and design
NASA Astrophysics Data System (ADS)
Castronuovo, Marco M.
2011-11-01
The active removal of five to ten large objects per year from the low Earth orbit (LEO) region is the only way to prevent the debris collisions from cascading. Among the three orbital regions near the Earth where most catastrophic collisions are predicted to occur, the one corresponding to a sun-synchronous condition is considered the most relevant. Forty-one large rocket bodies orbiting in this belt have been identified as the priority targets for removal. As part of a more comprehensive system engineering solution, a space mission dedicated to the de-orbiting of five rocket bodies per year from this orbital regime has been designed. The selected concept of operations envisages the launch of a satellite carrying a number of de-orbiting devices, such as solid propellant kits. The satellite performs a rendezvous with an identified object and mates with it by means of a robotic arm. A de-orbiting device is attached to the object by means of a second robotic arm, the object is released and the device is activated. The spacecraft travels then to the next target. The present paper shows that an active debris removal mission capable of de-orbiting 35 large objects in 7 years is technically feasible, and the resulting propellant mass budget is compatible with many existing platforms.
Sridhara Rao, Duggi V; Sankarasubramanian, Ramachandran; Muraleedharan, Kuttanellore; Mehrtens, Thorsten; Rosenauer, Andreas; Banerjee, Dipankar
2014-08-01
In GaAs-based pseudomorphic high-electron mobility transistor device structures, strain and composition of the In x Ga1-x As channel layer are very important as they influence the electronic properties of these devices. In this context, transmission electron microscopy techniques such as (002) dark-field imaging, high-resolution transmission electron microscopy (HRTEM) imaging, scanning transmission electron microscopy-high angle annular dark field (STEM-HAADF) imaging and selected area diffraction, are useful. A quantitative comparative study using these techniques is relevant for assessing the merits and limitations of the respective techniques. In this article, we have investigated strain and composition of the In x Ga1-x As layer with the mentioned techniques and compared the results. The HRTEM images were investigated with strain state analysis. The indium content in this layer was quantified by HAADF imaging and correlated with STEM simulations. The studies showed that the In x Ga1-x As channel layer was pseudomorphically grown leading to tetragonal strain along the [001] growth direction and that the average indium content (x) in the epilayer is ~0.12. We found consistency in the results obtained using various methods of analysis.
Controlled Defects of Fluorine-incorporated ZnO Nanorods for Photovoltaic Enhancement
Lee, Hock Beng; Ginting, Riski Titian; Tan, Sin Tee; Tan, Chun Hui; Alshanableh, Abdelelah; Oleiwi, Hind Fadhil; Yap, Chi Chin; Jumali, Mohd Hafizuddin Hj.; Yahaya, Muhammad
2016-01-01
Anion passivation effect on metal-oxide nano-architecture offers a highly controllable platform for improving charge selectivity and extraction, with direct relevance to their implementation in hybrid solar cells. In current work, we demonstrated the incorporation of fluorine (F) as an anion dopant to address the defect-rich nature of ZnO nanorods (ZNR) and improve the feasibility of its role as electron acceptor. The detailed morphology evolution and defect engineering on ZNR were studied as a function of F-doping concentration (x). Specifically, the rod-shaped arrays of ZnO were transformed into taper-shaped arrays at high x. A hypsochromic shift was observed in optical energy band gap due to the Burstein-Moss effect. A substantial suppression on intrinsic defects in ZnO lattice directly epitomized the novel role of fluorine as an oxygen defect quencher. The results show that 10-FZNR/P3HT device exhibited two-fold higher power conversion efficiency than the pristine ZNR/P3HT device, primarily due to the reduced Schottky defects and charge transfer barrier. Essentially, the reported findings yielded insights on the functions of fluorine on (i) surface –OH passivation, (ii) oxygen vacancies (Vo) occupation and (iii) lattice oxygen substitution, thereby enhancing the photo-physical processes, carrier mobility and concentration of FZNR based device. PMID:27587295
Options for temporary mechanical circulatory support
Saffarzadeh, Areo
2015-01-01
Temporary mechanical circulatory support (MCS) refers to a group of devices generally used for less than 30 days to maintain adequate organ perfusion by compensating for a failure of the pumping mechanism of the heart. The increased availability and rapid adoption of new temporary MCS strategies necessitate physicians to become familiar with devices placed both percutaneously and via median sternotomy. This review will examine the different options for commonly used temporary MCS devices including intra-aortic balloon pumps (IABPs), veno-arterial-extracorporeal membrane oxygenation (VA-ECMO), TandemHeart® (CardiacAssist, Pittsburg, PA, USA) Impella® and BVS 5000® (both Abiomed Inc., Danvers, MA, USA), CentriMag® and Thoratec percutaneous ventricular assist device (pVAD)® (both Thoratec Corporation, Pleasanton, CA, USA). A specific emphasis will be made to describe relevant mechanisms of action, standard placement strategies, hemodynamic effects, relevant contraindications and complications, and important daily management considerations. PMID:26793330
Neuroprosthetics and the science of patient input
Civillico, Eugene F.
2017-01-01
Safe and effective neuroprosthetic systems are of great interest to both DARPA and CDRH, due to their innovative nature and their potential to aid severely disabled populations. By expanding what is possible in human-device interaction, these devices introduce new potential benefits and risks. Therefore patient input, which is increasingly important in weighing benefits and risks, is particularly relevant for this class of devices. FDA has been a significant contributor to an ongoing stakeholder conversation about the inclusion of the patient voice, working collaboratively to create a new framework for a patient-centered approach to medical device development. This framework is evolving through open dialogue with researcher and patient communities, investment in the science of patient input, and policymaking that is responsive to patient-centered data throughout the total product life cycle. In this commentary, we will discuss recent developments in patient-centered benefit-risk assessment and their relevance to the development of neural prosthetic systems. PMID:27456271
Neuroprosthetics and the science of patient input.
Benz, Heather L; Civillico, Eugene F
2017-01-01
Safe and effective neuroprosthetic systems are of great interest to both DARPA and CDRH, due to their innovative nature and their potential to aid severely disabled populations. By expanding what is possible in human-device interaction, these devices introduce new potential benefits and risks. Therefore patient input, which is increasingly important in weighing benefits and risks, is particularly relevant for this class of devices. FDA has been a significant contributor to an ongoing stakeholder conversation about the inclusion of the patient voice, working collaboratively to create a new framework for a patient-centered approach to medical device development. This framework is evolving through open dialogue with researcher and patient communities, investment in the science of patient input, and policymaking that is responsive to patient-centered data throughout the total product life cycle. In this commentary, we will discuss recent developments in patient-centered benefit-risk assessment and their relevance to the development of neural prosthetic systems. Published by Elsevier Inc.
Assistive devices for balance and mobility: benefits, demands, and adverse consequences.
Bateni, Hamid; Maki, Brian E
2005-01-01
To provide information on the advantages and possible disadvantages of using canes and walkers. English-language articles were identified by searching MEDLINE and PubMed (1966-May 2003) for key words cane or walker , excluding articles unrelated to mobility aids. Bibliographies were reviewed and ISI Web of Science citation searches were run to identify additional references. Over 1000 articles were selected for further evaluation. We extracted all studies of single-tip canes or pickup walkers addressing: (1) functional, biomechanic, or neuromotor benefits; (2) biomechanic, attentional, neuromotor, metabolic, or physiologic demands; and (3) falls, injuries, or other problems. We included approximately 10% of the articles originally identified. The methodology of each selected article, and findings relevant to the benefits, demands, or adverse effects of cane or walker use were summarized. Findings were synthesized by considering their relation to basic biomechanic principles. Some biomechanic findings appear to support the clinical view that canes and walkers can improve balance and mobility for older adults and people with other clinical conditions. However, a large proportion of users experience difficulties, and the use of such devices is associated with increased risk of falling. A small number of studies have characterized some of the specific demands and problems associated with using mobility aids. Clinical and biomechanic evaluations of canes and walkers confirm that these devices can improve balance and mobility. However, they can also interfere with ones ability to maintain balance in certain situations, and the strength and metabolic demands can be excessive. More research is needed to identify and solve specific problems. Such research may lead to improved designs and guidelines for safer use of canes and walkers.
Effectiveness of robot-assisted therapy on ankle rehabilitation--a systematic review.
Zhang, Mingming; Davies, T Claire; Xie, Shane
2013-03-21
The aim of this study was to provide a systematic review of studies that investigated the effectiveness of robot-assisted therapy on ankle motor and function recovery from musculoskeletal or neurologic ankle injuries. Thirteen electronic databases of articles published from January, 1980 to June, 2012 were searched using keywords 'ankle*', 'robot*', 'rehabilitat*' or 'treat*' and a free search in Google Scholar based on effects of ankle rehabilitation robots was also conducted. References listed in relevant publications were further screened. Eventually, twenty-nine articles were selected for review and they focused on effects of robot-assisted ankle rehabilitation. Twenty-nine studies met the inclusion criteria and a total of 164 patients and 24 healthy subjects participated in these trials. Ankle performance and gait function were the main outcome measures used to assess the therapeutic effects of robot-assisted ankle rehabilitation. The protocols and therapy treatments were varied, which made comparison among different studies difficult or impossible. Few comparative trials were conducted among different devices or control strategies. Moreover, the majority of study designs met levels of evidence that were no higher than American Academy for Cerebral Palsy (CP) and Developmental Medicine (AACPDM) level IV. Only one study used a Randomized Control Trial (RCT) approach with the evidence level being II. All the selected studies showed improvements in terms of ankle performance or gait function after a period of robot-assisted ankle rehabilitation training. The most effective robot-assisted intervention cannot be determined due to the lack of universal evaluation criteria for various devices and control strategies. Future research into the effects of robot-assisted ankle rehabilitation should be carried out based on universal evaluation criteria, which could determine the most effective method of intervention. It is also essential to conduct trials to analyse the differences among different devices or control strategies.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
.... For those without Internet access, please call the contact person to register. Early registration is... access of medical devices to the market. On July 29, 2011, IOM released the report ``Medical Devices and..., and other relevant information will be posted, as it becomes available, on the Internet at http://www...
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
NASA Astrophysics Data System (ADS)
George, M. A.; Azoulay, M.; Jayatirtha, H. N.; Burger, A.; Collins, W. E.; Silberman, E.
1993-10-01
X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) was used for the first time to characterize the chemical composition of modified surfaces of Zn xCd 1- xTe single crystals. These surface treatments were selected for their relevance to device preparation procedures. The XPS peaks indicated an increase of the tellurium and a depletion of the cadmium concentrations upon etching in bromine methanol solution. AFM revealed the formation of pronounced Te inclusions. Higher x values correlated with a decrease in residual bromine left on the surface, while cut and polished samples had higher oxide concentrations and increased bromination of the surface than cleaved samples.
Artwork visualization using a solid-state lighting engine with controlled photochemical safety.
Tuzikas, Arūnas; Žukauskas, Artūras; Vaicekauksas, Rimantas; Petrulis, Andrius; Vitta, Pranciškus; Shur, Michael
2014-07-14
A concept of a solid-state lighting engine for artwork-specific illumination with controlled photochemical safety is introduced. The engine is based on a tetrachromatic cluster of colored light-emitting diodes wirelessly controlled via an external smart device. By using an instantaneous dimming functionality, the driving software allows for maintaining the damage irradiance relevant to a particular type of photosensitive artwork material at a constant value, while varying the chromaticity and color rendition properties of the generated light. The effect of the constant damage irradiance on the visual impression from artworks is demonstrated for the lighting engine operating in three modes, such as selecting color temperature, tuning color saturating ability, and shifting chromaticity outside white light locus, respectively.
Elsdon, Dale S; Spanswick, Selina; Zaslawski, Chris; Meier, Peter C
2017-01-01
A protocol for a prospective single-blind parallel four-arm randomized placebo-controlled trial with repeated measures was designed to test the effects of various acupuncture methods compared with sham. Eighty self-selected participants with myofascial pain in the upper trapezius muscle were randomized into four groups. Group 1 received acupuncture to a myofascial trigger point (MTrP) in the upper trapezius. Group 2 received acupuncture to the MTrP in addition to relevant distal points. Group 3 received acupuncture to the relevant distal points only. Group 4 received a sham treatment to both the MTrP and distal points using a deactivated acupuncture laser device. Treatment was applied four times within 2 weeks with outcomes measured throughout the trial and at 2 weeks and 4 weeks posttreatment. Outcome measurements were a 100-mm visual analog pain scale, SF-36, pressure pain threshold, Neck Disability Index, the Upper Extremity Functional Index, lateral flexion in the neck, McGill Pain Questionnaire, Massachusetts General Hospital Acupuncture Sensation Scale, Working Alliance Inventory (short form), and the Credibility Expectance Questionnaire. Two-way analysis of variance (ANOVA) with repeated measures were used to assess the differences between groups. Copyright © 2017 Medical Association of Pharmacopuncture Institute. Published by Elsevier B.V. All rights reserved.
[Comparative study of device labeling regulation in U.S.A. and China].
Li, Fei; Wei, Jing; Ma, Yanbin; Li, Zhu
2010-09-01
To provide references for the evolvement of medical devices labeling and manual administration in China, By content analysis, 10 juristic documents relevant to device labeling and manual were collected from FDA website, compared to which, the federal regulation was mainly analyzed. There are five main differences of device labeling regulation between U.S.A. and China: juristic system, administrative scope, administrative target, characteristics and practice, A set of comprehensive juristic system for device labeling has been established by FDA. from which China should draw experience, to administrate the prescription devices and the over-the-counter devices in classification, and set up device labeling guidance, thus guarantee the safety and efficacy of device.
Android Smartphone Relevance to Military Weather Applications
2011-10-01
lithium -ion battery that may be replaced by the user (unlike Apple iPod Touch devices), thus spare batteries can be carried. If there is only sporadic...Android Smartphone Relevance to Military Weather Applications by David Sauter ARL-TR-5793 October 2011...Android Smartphone Relevance to Military Weather Applications David Sauter Computational and Information Sciences Directorate, ARL
Point-of-Care Diagnostics for Niche Applications
Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054
Wolde, Mistire; Tarekegn, Getahun; Kebede, Tedla
2018-05-01
Point-of-care glucometer (PoCG) devices play a significant role in self-monitoring of the blood sugar level, particularly in the follow-up of high blood sugar therapeutic response. The aim of this study was to evaluate blood glucose test results performed with four randomly selected glucometers on diabetes and control subjects versus standard wet chemistry (hexokinase) methods in Addis Ababa, Ethiopia. A prospective cross-sectional study was conducted on randomly selected 200 study participants (100 participants with diabetes and 100 healthy controls). Four randomly selected PoCG devices (CareSens N, DIAVUE Prudential, On Call Extra, i-QARE DS-W) were evaluated against hexokinase method and ISO 15197:2003 and ISO 15197:2013 standards. The minimum and maximum blood sugar values were recorded by CareSens N (21 mg/dl) and hexokinase method (498.8 mg/dl), respectively. The mean sugar values of all PoCG devices except On Call Extra showed significant differences compared with the reference hexokinase method. Meanwhile, all four PoCG devices had strong positive relationship (>80%) with the reference method (hexokinase). On the other hand, none of the four PoCG devices fulfilled the minimum accuracy measurement set by ISO 15197:2003 and ISO 15197:2013 standards. In addition, the linear regression analysis revealed that all four selected PoCG overestimated the glucose concentrations. The overall evaluation of the selected four PoCG measurements were poorly correlated with standard reference method. Therefore, before introducing PoCG devices to the market, there should be a standardized evaluation platform for validation. Further similar large-scale studies on other PoCG devices also need to be undertaken.
Conference on Charge-Coupled Device Technology and Applications
NASA Technical Reports Server (NTRS)
1976-01-01
Papers were presented from the conference on charge coupled device technology and applications. The following topics were investigated: data processing; infrared; devices and testing; electron-in, x-ray, radiation; and applications. The emphasis was on the advances of mutual relevance and potential significance both to industry and NASA's current and future requirements in all fields of imaging, signal processing and memory.
Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review
Bocan, Kara N.; Sejdić, Ervin
2016-01-01
Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to sense and adapt to environmental variations in wireless transcutaneous systems. Adaptive systems provide the ability to maintain performance in the face of both unpredictability (variation from expected parameters) and variability (changes over time). Current strategies in adaptive (or tunable) systems include sensing relevant metrics to evaluate the function of the system in its environment and adjusting control parameters according to sensed values through the use of tunable components. Some challenges of applying adaptive designs to implantable devices are challenges common to all implantable devices, including size and power reduction on the implant, efficiency of power transfer and safety related to energy absorption in tissue. Challenges specifically associated with adaptation include choosing relevant and accessible parameters to sense and adjust, minimizing the tuning time and complexity of control, utilizing feedback from the implanted device and coordinating adaptation at the transmitter and receiver. PMID:26999154
Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review.
Bocan, Kara N; Sejdić, Ervin
2016-03-18
Wireless energy transfer is a broad research area that has recently become applicable to implantable medical devices. Wireless powering of and communication with implanted devices is possible through wireless transcutaneous energy transfer. However, designing wireless transcutaneous systems is complicated due to the variability of the environment. The focus of this review is on strategies to sense and adapt to environmental variations in wireless transcutaneous systems. Adaptive systems provide the ability to maintain performance in the face of both unpredictability (variation from expected parameters) and variability (changes over time). Current strategies in adaptive (or tunable) systems include sensing relevant metrics to evaluate the function of the system in its environment and adjusting control parameters according to sensed values through the use of tunable components. Some challenges of applying adaptive designs to implantable devices are challenges common to all implantable devices, including size and power reduction on the implant, efficiency of power transfer and safety related to energy absorption in tissue. Challenges specifically associated with adaptation include choosing relevant and accessible parameters to sense and adjust, minimizing the tuning time and complexity of control, utilizing feedback from the implanted device and coordinating adaptation at the transmitter and receiver.
Steele, Kerry D [Kennewick, WA; Anderson, Gordon A [Benton City, WA; Gilbert, Ronald W [Morgan Hill, CA
2011-02-01
Communications device identification methods, communications methods, wireless communications readers, wireless communications systems, and articles of manufacture are described. In one aspect, a communications device identification method includes providing identification information regarding a group of wireless identification devices within a wireless communications range of a reader, using the provided identification information, selecting one of a plurality of different search procedures for identifying unidentified ones of the wireless identification devices within the wireless communications range, and identifying at least some of the unidentified ones of the wireless identification devices using the selected one of the search procedures.
Bhakta, Samir A.; Evans, Elizabeth; Benavidez, Tomás E.; Garcia, Carlos D.
2014-01-01
An important consideration for the development of biosensors is the adsorption of the bio recognition element to the surface of a substrate. As the first step in the immobilization process, adsorption affects most immobilization routes and much attention is given into the research of this process to maximize the overall activity of the bio sensor. The use of nanomaterials, specifically nanoparticles and nanostructured films, offers advantageous properties that can be fine-tuned for interaction with specific proteins to maximize activity, minimize structural changes, and enhance the catalytic step. In the biosensor field, protein-nanomaterial interactions are an emerging trend that span across many disciplines. This review addresses recent publications about the proteins most frequently used, their most relevant characteristics, and the conditions required to adsorb them to nanomaterials. When relevant and available, subsequent analytical figures of merits are discussed for selected biosensors. The general trend amongst the research papers allows concluding that the use of nanomaterials has already provided significant improvements in the analytical performance of many biosensors and that this research field will continue to grow. PMID:25892065
Inductively coupled plasma mass spectrometry (ICP MS): a versatile tool.
Ammann, Adrian A
2007-04-01
Inductively coupled plasma (ICP) mass spectrometry (MS) is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and matrices introduced by a variety of specialized devices. Outstanding properties such as high sensitivity (ppt-ppq), relative salt tolerance, compound-independent element response and highest quantitation accuracy lead to the unchallenged performance of ICP MS in efficiently detecting, identifying and reliably quantifying trace elements. The increasing availability of relevant reference compounds and high separation selectivity extend the molecular identification capability of ICP MS hyphenated to species-specific separation techniques. While molecular ion source MS is specialized in determining the structure of unknown molecules, ICP MS is an efficient and highly sensitive tool for target-element orientated discoveries of relevant and unknown compounds. This special-feature, tutorial article presents the principle and advantages of ICP MS, highlighting these using examples from recently published investigations. Copyright 2007 John Wiley & Sons, Ltd.
Unsupervised feature relevance analysis applied to improve ECG heartbeat clustering.
Rodríguez-Sotelo, J L; Peluffo-Ordoñez, D; Cuesta-Frau, D; Castellanos-Domínguez, G
2012-10-01
The computer-assisted analysis of biomedical records has become an essential tool in clinical settings. However, current devices provide a growing amount of data that often exceeds the processing capacity of normal computers. As this amount of information rises, new demands for more efficient data extracting methods appear. This paper addresses the task of data mining in physiological records using a feature selection scheme. An unsupervised method based on relevance analysis is described. This scheme uses a least-squares optimization of the input feature matrix in a single iteration. The output of the algorithm is a feature weighting vector. The performance of the method was assessed using a heartbeat clustering test on real ECG records. The quantitative cluster validity measures yielded a correctly classified heartbeat rate of 98.69% (specificity), 85.88% (sensitivity) and 95.04% (general clustering performance), which is even higher than the performance achieved by other similar ECG clustering studies. The number of features was reduced on average from 100 to 18, and the temporal cost was a 43% lower than in previous ECG clustering schemes. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
2014-10-01
properties in Army-relevant semiconductor materials and optoelectronic ( OE ) devices by developing and applying ultrafast optical spectroscopy techniques...met our Q6 through Q8 goals of incorporating electrical testing capabilities into our system, investigating OE devices under operating conditions...extending the capabilities of our system into the IR range, and investigating new OE devices. We have made significant progress towards our Q5 goal of
Material selection for climbing hardware using the example of a belay device
NASA Astrophysics Data System (ADS)
Semenov, E.; Schwanitz, S.; Odenwald, S.
2017-03-01
The aim of the research project was to design a novel climbing belay device. The present article describes the details of the therefor performed material selection. Literature research on the materials used in commercially available belay devices revealed a lack of definite information. Thus, a pilot x-ray fluorescence (XRF) test was performed on a small sample of common aluminium belay devices. It revealed the use of a variety of different alloy systems. The selection process continued by compiling a thorough list of constraints and objectives for this safety related piece of sports equipment. Different material options including non-aluminium-materials were discussed. The final material choice was a high strength aluminium alloy with a T6 thermal treatment. The device was designed and calculated by use of CAD and FEM software respectively, aiming to reduce weight. After manufacturing the strength, usability and friction properties of the device have been successfully tested.
Highly Selective and Rapid Breath Isoprene Sensing Enabled by Activated Alumina Filter.
van den Broek, Jan; Güntner, Andreas T; Pratsinis, Sotiris E
2018-03-23
Isoprene is a versatile breath marker for noninvasive monitoring of high blood cholesterol levels as well as for influenza, end-stage renal disease, muscle activity, lung cancer, and liver disease with advanced fibrosis. Its selective detection in complex human breath by portable devices (e.g., metal-oxide gas sensors), however, is still challenging. Here, we present a new filter concept based on activated alumina powder enabling fast and highly selective detection of isoprene at the ppb level and high humidity. The filter contains high surface area adsorbents that retain hydrophilic compounds (e.g., ketones, alcohols, ammonia) representing major interferants in breath while hydrophobic isoprene is not affected. As a proof-of-concept, filters of commercial activated alumina powder are combined with highly sensitive but rather nonspecific, nanostructured Pt-doped SnO 2 sensors. This results in fast (10 s) measurement of isoprene down to 5 ppb at 90% relative humidity with outstanding selectivity (>100) to breath-relevant acetone, ammonia, ethanol, and methanol, superior to state-of-the-art isoprene sensors. Most importantly, when exposed continuously to simulated breath mixtures (four analytes) for 8 days, this filter-sensor system showed stable performance. It can be incorporated readily into a portable breath isoprene analyzer promising for simple-in-use monitoring of blood cholesterol or other patho/physiological conditions.
Solid-state energy storage module employing integrated interconnect board
Rouillard, Jean; Comte, Christophe; Daigle, Dominik; Hagen, Ronald A.; Knudson, Orlin B.; Morin, Andre; Ranger, Michel; Ross, Guy; Rouillard, Roger; St-Germain, Philippe; Sudano, Anthony; Turgeon, Thomas A.
2003-11-04
The present invention is directed to an improved electrochemical energy storage device. The electrochemical energy storage device includes a number of solid-state, thin-film electrochemical cells which are selectively interconnected in series or parallel through use of an integrated interconnect board. The interconnect board is typically disposed within a sealed housing which also houses the electrochemical cells, and includes a first contact and a second contact respectively coupled to first and second power terminals of the energy storage device. The interconnect board advantageously provides for selective series or parallel connectivity with the electrochemical cells, irrespective of electrochemical cell position within the housing. Fuses and various electrical and electromechanical devices, such as bypass, equalization, and communication devices for example, may also be mounted to the interconnect board and selectively connected to the electrochemical cells.
Micklash. II, Kenneth James; Dutton, Justin James; Kaye, Steven
2014-06-03
An apparatus for testing of multiple material samples includes a gas delivery control system operatively connectable to the multiple material samples and configured to provide gas to the multiple material samples. Both a gas composition measurement device and pressure measurement devices are included in the apparatus. The apparatus includes multiple selectively openable and closable valves and a series of conduits configured to selectively connect the multiple material samples individually to the gas composition device and the pressure measurement devices by operation of the valves. A mixing system is selectively connectable to the series of conduits and is operable to cause forced mixing of the gas within the series of conduits to achieve a predetermined uniformity of gas composition within the series of conduits and passages.
The role of assistive robotics in the lives of persons with disability.
Brose, Steven W; Weber, Douglas J; Salatin, Ben A; Grindle, Garret G; Wang, Hongwu; Vazquez, Juan J; Cooper, Rory A
2010-06-01
Robotic assistive devices are used increasingly to improve the independence and quality of life of persons with disabilities. Devices as varied as robotic feeders, smart-powered wheelchairs, independent mobile robots, and socially assistive robots are becoming more clinically relevant. There is a growing importance for the rehabilitation professional to be aware of available systems and ongoing research efforts. The aim of this article is to describe the advances in assistive robotics that are relevant to professionals serving persons with disabilities. This review breaks down relevant advances into categories of Assistive Robotic Systems, User Interfaces and Control Systems, Sensory and Feedback Systems, and User Perspectives. An understanding of the direction that assistive robotics is taking is important for the clinician and researcher alike; this review is intended to address this need.
Sakas, D E; Panourias, I G; Simpson, B A
2007-01-01
Operative Neuromodulation is the field of altering electrically or chemically the signal transmission in the nervous system by implanted devices in order to excite, inhibit or tune the activities of neurons or neural networks and produce therapeutic effects. The present article reviews relevant literature on procedures or devices applied either in contact with the cerebral cortex or cranial nerves or in deep sites inside the brain in order to treat various refractory neurological conditions such as: a) chronic pain (facial, somatic, deafferentation, phantom limb), b) movement disorders (Parkinson's disease, dystonia, Tourette syndrome), c) epilepsy, d) psychiatric disease, e) hearing deficits, and f) visual loss. These data indicate that in operative neuromodulation, a new field emerges that is based on neural networks research and on advances in digitised stereometric brain imaging which allow precise localisation of cerebral neural networks and their relay stations; this field can be described as Neural networks surgery because it aims to act extrinsically or intrinsically on neural networks and to alter therapeutically the neural signal transmission with the use of implantable electrical or electronic devices. The authors also review neurotechnology literature relevant to neuroengineering, nanotechnologies, brain computer interfaces, hybrid cultured probes, neuromimetics, neuroinformatics, neurocomputation, and computational neuromodulation; the latter field is dedicated to the study of the biophysical and mathematical characteristics of electrochemical neuromodulation. The article also brings forward particularly interesting lines of research such as the carbon nanofibers electrode arrays for simultaneous electrochemical recording and stimulation, closed-loop systems for responsive neuromodulation, and the intracortical electrodes for restoring hearing or vision. The present review of cerebral neuromodulatory procedures highlights the transition from the conventional neurosurgery of resective or ablative techniques to a highly selective "surgery of networks". The dynamics of the convergence of the above biomedical and technological fields with biological restorative approaches have important implications for patients with severe neurological disorders.
Balcarras, Matthew; Ardid, Salva; Kaping, Daniel; Everling, Stefan; Womelsdorf, Thilo
2016-02-01
Attention includes processes that evaluate stimuli relevance, select the most relevant stimulus against less relevant stimuli, and bias choice behavior toward the selected information. It is not clear how these processes interact. Here, we captured these processes in a reinforcement learning framework applied to a feature-based attention task that required macaques to learn and update the value of stimulus features while ignoring nonrelevant sensory features, locations, and action plans. We found that value-based reinforcement learning mechanisms could account for feature-based attentional selection and choice behavior but required a value-independent stickiness selection process to explain selection errors while at asymptotic behavior. By comparing different reinforcement learning schemes, we found that trial-by-trial selections were best predicted by a model that only represents expected values for the task-relevant feature dimension, with nonrelevant stimulus features and action plans having only a marginal influence on covert selections. These findings show that attentional control subprocesses can be described by (1) the reinforcement learning of feature values within a restricted feature space that excludes irrelevant feature dimensions, (2) a stochastic selection process on feature-specific value representations, and (3) value-independent stickiness toward previous feature selections akin to perseveration in the motor domain. We speculate that these three mechanisms are implemented by distinct but interacting brain circuits and that the proposed formal account of feature-based stimulus selection will be important to understand how attentional subprocesses are implemented in primate brain networks.
Design optimization of first wall and breeder unit module size for the Indian HCCB blanket module
NASA Astrophysics Data System (ADS)
Deepak, SHARMA; Paritosh, CHAUDHURI
2018-04-01
The Indian test blanket module (TBM) program in ITER is one of the major steps in the Indian fusion reactor program for carrying out the R&D activities in the critical areas like design of tritium breeding blankets relevant to future Indian fusion devices (ITER relevant and DEMO). The Indian Lead–Lithium Cooled Ceramic Breeder (LLCB) blanket concept is one of the Indian DEMO relevant TBM, to be tested in ITER as a part of the TBM program. Helium-Cooled Ceramic Breeder (HCCB) is an alternative blanket concept that consists of lithium titanate (Li2TiO3) as ceramic breeder (CB) material in the form of packed pebble beds and beryllium as the neutron multiplier. Specifically, attentions are given to the optimization of first wall coolant channel design and size of breeder unit module considering coolant pressure and thermal loads for the proposed Indian HCCB blanket based on ITER relevant TBM and loading conditions. These analyses will help proceeding further in designing blankets for loads relevant to the future fusion device.
Clinical efficacy and effectiveness of 3D printing: a systematic review.
Diment, Laura E; Thompson, Mark S; Bergmann, Jeroen H M
2017-12-21
To evaluate the clinical efficacy and effectiveness of using 3D printing to develop medical devices across all medical fields. Systematic review compliant with Preferred Reporting Items for Systematic Reviews and Meta-Analyses. PubMed, Web of Science, OVID, IEEE Xplore and Google Scholar. A double-blinded review method was used to select all abstracts up to January 2017 that reported on clinical trials of a three-dimensional (3D)-printed medical device. The studies were ranked according to their level of evidence, divided into medical fields based on the International Classification of Diseases chapter divisions and categorised into whether they were used for preoperative planning, aiding surgery or therapy. The Downs and Black Quality Index critical appraisal tool was used to assess the quality of reporting, external validity, risk of bias, risk of confounding and power of each study. Of the 3084 abstracts screened, 350 studies met the inclusion criteria. Oral and maxillofacial surgery contained 58.3% of studies, and 23.7% covered the musculoskeletal system. Only 21 studies were randomised controlled trials (RCTs), and all fitted within these two fields. The majority of RCTs were 3D-printed anatomical models for preoperative planning and guides for aiding surgery. The main benefits of these devices were decreased surgical operation times and increased surgical accuracy. All medical fields that assessed 3D-printed devices concluded that they were clinically effective. The fields that most rigorously assessed 3D-printed devices were oral and maxillofacial surgery and the musculoskeletal system, both of which concluded that the 3D-printed devices outperformed their conventional comparators. However, the efficacy and effectiveness of 3D-printed devices remain undetermined for the majority of medical fields. 3D-printed devices can play an important role in healthcare, but more rigorous and long-term assessments are needed to determine if 3D-printed devices are clinically relevant before they become part of standard clinical practice. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Tribology of magnetic storage systems
NASA Technical Reports Server (NTRS)
Bhushan, Bharat
1992-01-01
The construction and the materials used in different magnetic storage devices are defined. The theories of friction and adhesion, interface temperatures, wear, and solid-liquid lubrication relevant to magnetic storage systems are presented. Experimental data are presented wherever possible to support the relevant theories advanced.
BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.
Bruzzi, M S; Linehan, J H
2013-09-01
In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by understanding deeply the issues involved in creating a useful device, how to raise money, designing early clinical studies and locating manufacturing partners.
Annual update: drugs, diagnostics and devices.
Berardinelli, Candace; Kupecz, Deborah
2003-03-01
As NPs continue to play an important role in health care as administers of prescriptions, the value of reviewing the latest Food and Drug Administration (FDA) approvals for new drugs and devices is immeasurable. In 2002, the FDA approved several new drugs and devices, as well as monitored previously approved drugs for adverse reactions and untoward events. This article provides a brief review of relevant primary care topics.
Classification of team sport activities using a single wearable tracking device.
Wundersitz, Daniel W T; Josman, Casey; Gupta, Ritu; Netto, Kevin J; Gastin, Paul B; Robertson, Sam
2015-11-26
Wearable tracking devices incorporating accelerometers and gyroscopes are increasingly being used for activity analysis in sports. However, minimal research exists relating to their ability to classify common activities. The purpose of this study was to determine whether data obtained from a single wearable tracking device can be used to classify team sport-related activities. Seventy-six non-elite sporting participants were tested during a simulated team sport circuit (involving stationary, walking, jogging, running, changing direction, counter-movement jumping, jumping for distance and tackling activities) in a laboratory setting. A MinimaxX S4 wearable tracking device was worn below the neck, in-line and dorsal to the first to fifth thoracic vertebrae of the spine, with tri-axial accelerometer and gyroscope data collected at 100Hz. Multiple time domain, frequency domain and custom features were extracted from each sensor using 0.5, 1.0, and 1.5s movement capture durations. Features were further screened using a combination of ANOVA and Lasso methods. Relevant features were used to classify the eight activities performed using the Random Forest (RF), Support Vector Machine (SVM) and Logistic Model Tree (LMT) algorithms. The LMT (79-92% classification accuracy) outperformed RF (32-43%) and SVM algorithms (27-40%), obtaining strongest performance using the full model (accelerometer and gyroscope inputs). Processing time can be reduced through feature selection methods (range 1.5-30.2%), however a trade-off exists between classification accuracy and processing time. Movement capture duration also had little impact on classification accuracy or processing time. In sporting scenarios where wearable tracking devices are employed, it is both possible and feasible to accurately classify team sport-related activities. Copyright © 2015 Elsevier Ltd. All rights reserved.
Blindness and Selective Mutism: One Student's Response to Voice-Output Devices
ERIC Educational Resources Information Center
Holley, Mary; Johnson, Ashli; Herzberg, Tina
2014-01-01
This case study was designed to measure the response of one student with blindness and selective mutism to the intervention of voice-output devices across two years and two different teachers in two instructional settings. Before the introduction of the voice output devices, the student did not choose to communicate using spoken language or…
Martins, Maria; Costa, Lino; Frizera, Anselmo; Ceres, Ramón; Santos, Cristina
2014-03-01
Walker devices are often prescribed incorrectly to patients, leading to the increase of dissatisfaction and occurrence of several problems, such as, discomfort and pain. Thus, it is necessary to objectively evaluate the effects that assisted gait can have on the gait patterns of walker users, comparatively to a non-assisted gait. A gait analysis, focusing on spatiotemporal and kinematics parameters, will be issued for this purpose. However, gait analysis yields redundant information that often is difficult to interpret. This study addresses the problem of selecting the most relevant gait features required to differentiate between assisted and non-assisted gait. For that purpose, it is presented an efficient approach that combines evolutionary techniques, based on genetic algorithms, and support vector machine algorithms, to discriminate differences between assisted and non-assisted gait with a walker with forearm supports. For comparison purposes, other classification algorithms are verified. Results with healthy subjects show that the main differences are characterized by balance and joints excursion in the sagittal plane. These results, confirmed by clinical evidence, allow concluding that this technique is an efficient feature selection approach. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
McConnell, Joshua B.
2000-01-01
The scientific exploration of Mars will require the collection and return of subterranean samples to Earth for examination. This necessitates the use of some type of device or devices that possesses the ability to effectively penetrate the Martian surface, collect suitable samples and return them to the surface in a manner consistent with imposed scientific constraints. The first opportunity for such a device will occur on the 2003 and 2005 Mars Sample Return missions, being performed by NASA. This paper reviews the work completed on the compilation of a database containing viable penetrating and sampling devices, the performance of a system level trade study comparing selected devices to a set of prescribed parameters and the employment of a metric for the evaluation and ranking of the traded penetration and sampling devices, with respect to possible usage on the 03 and 05 sample return missions. The trade study performed is based on a select set of scientific, engineering, programmatic and socio-political criterion. The use of a metric for the various penetration and sampling devices will act to expedite current and future device selection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kupriyanov, M. S., E-mail: mikhail.kupriyanov@gmail.com; Shukeilo, E. Y., E-mail: eyshukeylo@gmail.com; Shichkina, J. A., E-mail: strange.y@mail.ru
2015-11-17
Nowadays technologies which are used in traumatology are a combination of mechanical, electronic, calculating and programming tools. Relevance of development of mobile applications for an expeditious data processing which are received from medical devices (in particular, wearable devices), and formulation of management decisions increases. Using of a mathematical method of building of decision trees for an assessment of a patient’s health condition using data from a wearable device considers in this article.
NASA Astrophysics Data System (ADS)
Kupriyanov, M. S.; Shukeilo, E. Y.; Shichkina, J. A.
2015-11-01
Nowadays technologies which are used in traumatology are a combination of mechanical, electronic, calculating and programming tools. Relevance of development of mobile applications for an expeditious data processing which are received from medical devices (in particular, wearable devices), and formulation of management decisions increases. Using of a mathematical method of building of decision trees for an assessment of a patient's health condition using data from a wearable device considers in this article.
Applying health economics for policy decision making: do devices differ from drugs?
Sorenson, Corinna; Tarricone, Rosanna; Siebert, Markus; Drummond, Michael
2011-05-01
Medical devices pose unique challenges for economic evaluation and associated decision-making processes that differ from pharmaceuticals. We highlight and discuss these challenges in the context of cardiac device therapy, based on a systematic review of relevant economic evaluations. Key challenges include practical difficulties in conducting randomized clinical trials, allowing for a 'learning curve' and user characteristics, accounting for the wider organizational impacts of introducing new devices, and allowing for variations in product characteristics and prices over time.
Point-of-care diagnostics for niche applications.
Cummins, Brian M; Ligler, Frances S; Walker, Glenn M
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.
Spectrally-engineered solar thermal photovoltaic devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lenert, Andrej; Bierman, David; Chan, Walker
A solar thermal photovoltaic device, and method of forming same, includes a solar absorber and a spectrally selective emitter formed on either side of a thermally conductive substrate. The solar absorber is configured to absorb incident solar radiation. The solar absorber and the spectrally selective emitter are configured with an optimized emitter-to-absorber area ratio. The solar thermal photovoltaic device also includes a photovoltaic cell in thermal communication with the spectrally selective emitter. The spectrally selective emitter is configured to permit high emittance for energies above a bandgap of the photovoltaic cell and configured to permit low emittance for energies belowmore » the bandgap.« less
Searching for Mirrors: Preservice Teachers' Journey toward More Culturally Relevant Pedagogy
ERIC Educational Resources Information Center
Christ, Tanya; Sharma, Sue Ann
2018-01-01
Culturally relevant text selection and pedagogy support students' motivation, engagement, literacy outcomes, and positive identity formation. Nevertheless, there is limited research on teacher preparation that fosters these outcomes. We explore 17 preservice teachers' challenges and successes with culturally relevant text selection and pedagogy…
A Conceptual Project of a Device for Human Wrist Functional Rehabilitation
NASA Astrophysics Data System (ADS)
Lewandowski, B.; Olinski, M.; Wudarczyk, S.; Gronowicz, A.
2016-12-01
In the paper, the problems of devices supporting functional rehabilitation of a human wrist were addressed. A literature review and a description of selected devices together with an indication of their advantages and disadvantages were conducted. The biomechanical structure of a human wrist was analyzed. On this basis and after taking into consideration ranges of motion of the selected joints the concept of a new mechanism was developed. A 3D model of the device was built in the Autodesk Inventor system. For the purpose of simulations another model was developed in the MSC Adams system. Issues of drives and sensors selection, as well as requirements for the control system, were examined.
Reconfigurable pipelined processor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saccardi, R.J.
1989-09-19
This patent describes a reconfigurable pipelined processor for processing data. It comprises: a plurality of memory devices for storing bits of data; a plurality of arithmetic units for performing arithmetic functions with the data; cross bar means for connecting the memory devices with the arithmetic units for transferring data therebetween; at least one counter connected with the cross bar means for providing a source of addresses to the memory devices; at least one variable tick delay device connected with each of the memory devices and arithmetic units; and means for providing control bits to the variable tick delay device formore » variably controlling the input and output operations thereof to selectively delay the memory devices and arithmetic units to align the data for processing in a selected sequence.« less
Super non-linear RRAM with ultra-low power for 3D vertical nano-crossbar arrays.
Luo, Qing; Xu, Xiaoxin; Liu, Hongtao; Lv, Hangbing; Gong, Tiancheng; Long, Shibing; Liu, Qi; Sun, Haitao; Banerjee, Writam; Li, Ling; Gao, Jianfeng; Lu, Nianduan; Liu, Ming
2016-08-25
Vertical crossbar arrays provide a cost-effective approach for high density three-dimensional (3D) integration of resistive random access memory. However, an individual selector device is not allowed to be integrated with the memory cell separately. The development of V-RRAM has impeded the lack of satisfactory self-selective cells. In this study, we have developed a high performance bilayer self-selective device using HfO2 as the memory switching layer and a mixed ionic and electron conductor as the selective layer. The device exhibits high non-linearity (>10(3)) and ultra-low half-select leakage (<0.1 pA). A four layer vertical crossbar array was successfully demonstrated based on the developed self-selective device. High uniformity, ultra-low leakage, sub-nA operation, self-compliance, and excellent read/write disturbance immunity were achieved. The robust array level performance shows attractive potential for low power and high density 3D data storage applications.
Nieset, R.T.
1961-05-16
A radio ranging device is described. It utilizes a super regenerative detector-oscillator in which echoes of transmitted pulses are received in proper phase to reduce noise energy at a selected range and also at multiples of the selected range.
Nastasi, Michael Anthony; Wang, Yongqiang; Fraboni, Beatrice; Cosseddu, Piero; Bonfiglio, Annalisa
2013-06-11
Organic thin film devices that included an organic thin film subjected to a selected dose of a selected energy of ions exhibited a stabilized mobility (.mu.) and threshold voltage (VT), a decrease in contact resistance R.sub.C, and an extended operational lifetime that did not degrade after 2000 hours of operation in the air.
A standardized safe hepatectomy; selective Glissonean transection using endolinear stapling devices.
Fujii, Masahiko; Shimada, Mitsuo; Satoru, Imura; Morine, Yuji; Ikemoto, Tetsuya; Soejima, Yuji
2007-01-01
Selective clamping of Glisson's pedicle at the hilum is effective for systematized hepatectomy. Because of the development of stapling devices, a Glissonean transection using a surgical stapler has been used widely. However, the risk of accidental stapling of the biliary confluence still remains. In this paper we report about a case that underwent selective Glissonean transection using an endolinear stapling device. We used this standardized technique in five patients without any major complications. The particular case to which we refer was a 71-year-old woman with hepatocellular carcinoma in the right lobe. The anterior and posterior branches of Glisson's pedicle were independently divided using an endolinear stapling device. The right hepatic lobectomy was achieved with little bleeding and in addition there was a shortened operation time and the postoperative course was uneventful. In the patient with liver cirrhosis, postoperative complications often related to liver failure. We herein advocate a standardized safe hepatectomy using endolinear stapling devices. We believe that the shortened operative time and decreased risk of complications by selective Glissonean transection as well as hepatic vein transection using stapling devices contribute to the improved short-term outcome.
Extended papers selected from ESSDERC 2015
NASA Astrophysics Data System (ADS)
Grasser, Tibor; Schmitz, Jurriaan; Lemme, Max C.
2016-11-01
This special issue of Solid State Electronics includes 28 papers which have been carefully selected from the best presentations given at the 45th European Solid-State Device Research Conference (ESSDERC 2015) held from September 14-18, 2015 in Graz, Austria. These papers cover a wide range of topics related to the research on solid-state devices. These topics are used also to organize the conference submissions and presentations into 7 tracks: CMOS Processes, Devices and Integration; Opto-, Power- and Microwave Devices; Modeling & Simulation; Characterization, Reliability & Yield; Advanced & Emerging Memories; MEMS, Sensors & Display Technologies; Emerging Non-CMOS Devices & Technologies.
Delattre, François; Cazier-Dennin, Francine; Leleu, Ludovic; Dewaele, Dorothée; Landy, David; Mallard, Isabelle; Danjou, Pierre-Edouard
2015-11-01
This work reports on an efficient microwave irradiation synthesis of a new fluorescent chemosensor based on desferrioxamine B (DFO-B) and carbazole moiety. Furthermore, this novel chemosensor was employed for a comparative study of real environmental samples of airbone particulate matter collected from Dunkirk (Northern of France). Among selected relevant metal cations present in its airbone particulate matter, such as Na(+), K(+), Mg(2+), Ca(2+), Al(3+), Cr(3+), Mn(2+) and Zn(2+), this molecular device proved to be outstandingly sensitive toward Fe(3+) with a limit of detection of 1.49 ppb (2.1×10(-8) M) in methanol allowing the estimation of total iron in atmospheric particles. Copyright © 2015 Elsevier B.V. All rights reserved.
Spectrophotometric determination of traces of boron in high purity silicon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parashar, D.C.; Sarkar, A.K.; Singh, N.
1989-07-01
A reddish brown complex is formed between boron and curcumin in concentrated sulfuric acid and glacial acetic acid mixture (1:1). The colored complex is highly selective and stable for about 3 hours and has the maximum absorbance at 545 nm. The sensitivity of the method is extremely high and the detection limit is 3 parts per billion based on 0.004 absorbance value. The interference of some of the important cations and anions relevant to silicon were studied and it is found that 100 fold excess of most of these cations and anions do not interfere in the determination of boron.more » The method is successfully employed for the determination of boron in silicon used in semiconductor devices. The results have been verified by standard addition method.« less
Advances in nano-scaled biosensors for biomedical applications.
Wang, Jianling; Chen, Guihua; Jiang, Hui; Li, Zhiyong; Wang, Xuemei
2013-08-21
Recently, a growing amount of attention has been focused on the utility of biosensors for biomedical applications. Combined with nanomaterials and nanostructures, nano-scaled biosensors are installed for biomedical applications, such as pathogenic bacteria monitoring, virus recognition, disease biomarker detection, among others. These nano-biosensors offer a number of advantages and in many respects are ideally suited to biomedical applications, which could be made as extremely flexible devices, allowing biomedical analysis with speediness, excellent selectivity and high sensitivity. This minireview discusses the literature published in the latest years on the advances in biomedical applications of nano-scaled biosensors for disease bio-marking and detection, especially in bio-imaging and the diagnosis of pathological cells and viruses, monitoring pathogenic bacteria, thus providing insight into the future prospects of biosensors in relevant clinical applications.
Tailored Codes for Small Quantum Memories
NASA Astrophysics Data System (ADS)
Robertson, Alan; Granade, Christopher; Bartlett, Stephen D.; Flammia, Steven T.
2017-12-01
We demonstrate that small quantum memories, realized via quantum error correction in multiqubit devices, can benefit substantially by choosing a quantum code that is tailored to the relevant error model of the system. For a biased noise model, with independent bit and phase flips occurring at different rates, we show that a single code greatly outperforms the well-studied Steane code across the full range of parameters of the noise model, including for unbiased noise. In fact, this tailored code performs almost optimally when compared with 10 000 randomly selected stabilizer codes of comparable experimental complexity. Tailored codes can even outperform the Steane code with realistic experimental noise, and without any increase in the experimental complexity, as we demonstrate by comparison in the observed error model in a recent seven-qubit trapped ion experiment.
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, Erika; Maremmani, Carlo; Cavallo, Filippo
2017-01-01
Background: Parkinson's disease (PD) is a common and disabling pathology that is characterized by both motor and non-motor symptoms and affects millions of people worldwide. The disease significantly affects quality of life of those affected. Many works in literature discuss the effects of the disease. The most promising trends involve sensor devices, which are low cost, low power, unobtrusive, and accurate in the measurements, for monitoring and managing the pathology. Objectives: This review focuses on wearable devices for PD applications and identifies five main fields: early diagnosis, tremor, body motion analysis, motor fluctuations (ON–OFF phases), and home and long-term monitoring. The concept is to obtain an overview of the pathology at each stage of development, from the beginning of the disease to consider early symptoms, during disease progression with analysis of the most common disorders, and including management of the most complicated situations (i.e., motor fluctuations and long-term remote monitoring). Data sources: The research was conducted within three databases: IEEE Xplore®, Science Direct®, and PubMed Central®, between January 2006 and December 2016. Study eligibility criteria: Since 1,429 articles were found, accurate definition of the exclusion criteria and selection strategy allowed identification of the most relevant papers. Results: Finally, 136 papers were fully evaluated and included in this review, allowing a wide overview of wearable devices for the management of Parkinson's disease. PMID:29056899
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review.
Rovini, Erika; Maremmani, Carlo; Cavallo, Filippo
2017-01-01
Background: Parkinson's disease (PD) is a common and disabling pathology that is characterized by both motor and non-motor symptoms and affects millions of people worldwide. The disease significantly affects quality of life of those affected. Many works in literature discuss the effects of the disease. The most promising trends involve sensor devices, which are low cost, low power, unobtrusive, and accurate in the measurements, for monitoring and managing the pathology. This review focuses on wearable devices for PD applications and identifies five main fields: early diagnosis, tremor, body motion analysis, motor fluctuations (ON-OFF phases), and home and long-term monitoring. The concept is to obtain an overview of the pathology at each stage of development, from the beginning of the disease to consider early symptoms, during disease progression with analysis of the most common disorders, and including management of the most complicated situations (i.e., motor fluctuations and long-term remote monitoring). The research was conducted within three databases: IEEE Xplore®, Science Direct®, and PubMed Central®, between January 2006 and December 2016. Since 1,429 articles were found, accurate definition of the exclusion criteria and selection strategy allowed identification of the most relevant papers. Finally, 136 papers were fully evaluated and included in this review, allowing a wide overview of wearable devices for the management of Parkinson's disease.
NASA Technical Reports Server (NTRS)
Alt, Shannon
2016-01-01
Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.
Hempstead, Joshua; Jones, Dustin P.; Ziouche, Abdelali; Cramer, Gwendolyn M.; Rizvi, Imran; Arnason, Stephen; Hasan, Tayyaba; Celli, Jonathan P.
2015-01-01
A lack of access to effective cancer therapeutics in resource-limited settings is implicated in global cancer health disparities between developed and developing countries. Photodynamic therapy (PDT) is a light-based treatment modality that has exhibited safety and efficacy in the clinic using wavelengths and irradiances achievable with light-emitting diodes (LEDs) operated on battery power. Here we assess low-cost enabling technology to extend the clinical benefit of PDT to regions with little or no access to electricity or medical infrastructure. We demonstrate the efficacy of a device based on a 635 nm high-output LED powered by three AA disposable alkaline batteries, to achieve strong cytotoxic response in monolayer and 3D cultures of A431 squamous carcinoma cells following photosensitization by administering aminolevulinic acid (ALA) to induce the accumulation of protoporphyrin IX (PpIX). Here we characterize challenges of battery-operated device performance, including battery drain and voltage stability specifically over relevant PDT dose parameters. Further motivated by the well-established capacity of PDT photosensitizers to serve as tumour-selective fluorescence contrast agents, we demonstrate the capability of a consumer smartphone with low-cost add-ons to measure concentration-dependent PpIX fluorescence. This study lays the groundwork for the on-going development of image-guided ALA-PDT treatment technologies for global health applications. PMID:25965295
Hempstead, Joshua; Jones, Dustin P; Ziouche, Abdelali; Cramer, Gwendolyn M; Rizvi, Imran; Arnason, Stephen; Hasan, Tayyaba; Celli, Jonathan P
2015-05-12
A lack of access to effective cancer therapeutics in resource-limited settings is implicated in global cancer health disparities between developed and developing countries. Photodynamic therapy (PDT) is a light-based treatment modality that has exhibited safety and efficacy in the clinic using wavelengths and irradiances achievable with light-emitting diodes (LEDs) operated on battery power. Here we assess low-cost enabling technology to extend the clinical benefit of PDT to regions with little or no access to electricity or medical infrastructure. We demonstrate the efficacy of a device based on a 635 nm high-output LED powered by three AA disposable alkaline batteries, to achieve strong cytotoxic response in monolayer and 3D cultures of A431 squamous carcinoma cells following photosensitization by administering aminolevulinic acid (ALA) to induce the accumulation of protoporphyrin IX (PpIX). Here we characterize challenges of battery-operated device performance, including battery drain and voltage stability specifically over relevant PDT dose parameters. Further motivated by the well-established capacity of PDT photosensitizers to serve as tumour-selective fluorescence contrast agents, we demonstrate the capability of a consumer smartphone with low-cost add-ons to measure concentration-dependent PpIX fluorescence. This study lays the groundwork for the on-going development of image-guided ALA-PDT treatment technologies for global health applications.
NASA Astrophysics Data System (ADS)
Hempstead, Joshua; Jones, Dustin P.; Ziouche, Abdelali; Cramer, Gwendolyn M.; Rizvi, Imran; Arnason, Stephen; Hasan, Tayyaba; Celli, Jonathan P.
2015-05-01
A lack of access to effective cancer therapeutics in resource-limited settings is implicated in global cancer health disparities between developed and developing countries. Photodynamic therapy (PDT) is a light-based treatment modality that has exhibited safety and efficacy in the clinic using wavelengths and irradiances achievable with light-emitting diodes (LEDs) operated on battery power. Here we assess low-cost enabling technology to extend the clinical benefit of PDT to regions with little or no access to electricity or medical infrastructure. We demonstrate the efficacy of a device based on a 635 nm high-output LED powered by three AA disposable alkaline batteries, to achieve strong cytotoxic response in monolayer and 3D cultures of A431 squamous carcinoma cells following photosensitization by administering aminolevulinic acid (ALA) to induce the accumulation of protoporphyrin IX (PpIX). Here we characterize challenges of battery-operated device performance, including battery drain and voltage stability specifically over relevant PDT dose parameters. Further motivated by the well-established capacity of PDT photosensitizers to serve as tumour-selective fluorescence contrast agents, we demonstrate the capability of a consumer smartphone with low-cost add-ons to measure concentration-dependent PpIX fluorescence. This study lays the groundwork for the on-going development of image-guided ALA-PDT treatment technologies for global health applications.
Not so ugly after all: when shame acts as a commitment device.
de Hooge, Ilona E; Breugelmans, Seger M; Zeelenberg, Marcel
2008-10-01
Most psychological theories and research on shame focus on the ugly aspects and negative consequences of this emotion. Theories on moral emotions, however, assume that shame acts as a commitment device motivating prosocial behavior. To solve this apparent paradox, the authors studied the effects of shame on prosocial behavior. Shame was hypothesized to motivate prosocial behavior when it was relevant for the decision at hand (endogenous). In contrast, shame that was not relevant for the decision at hand (exogenous) was hypothesized to have no such effects. Four experiments with three different shame inductions and two different measures of prosocial behavior confirmed that endogenous shame motivated prosocial behavior for proselfs but that exogenous shame did not. Shame is shown to have a clear interpersonal function in the sense that it acts as a commitment device.
Torres, Juan C; Vergaz, Ricardo; Barrios, David; Sánchez-Pena, José Manuel; Viñuales, Ana; Grande, Hans Jürgen; Cabañero, Germán
2014-05-02
A series of polymer dispersed liquid crystal devices using glass substrates have been fabricated and investigated focusing on their electrical properties. The devices have been studied in terms of impedance as a function of frequency. An electric equivalent circuit has been proposed, including the influence of the temperature on the elements into it. In addition, a relevant effect of temperature on electrical measurements has been observed.
NASA Astrophysics Data System (ADS)
Budhwani, Karim Ismail
The tremendous quality of life impact notwithstanding, cardiovascular diseases and Cancer add up to over US$ 700bn each year in financial costs alone. Aging and population growth are expected to further expand the problem space while drug research and development remain expensive. However, preclinical costs can be substantially mitigated by substituting animal models with in vitro devices that accurately model human cardiovascular transport. Here we present a novel physiologically relevant lab-on-a-brane that simulates in vivo pressure, flow, strain, and shear waveforms associated with normal and pathological conditions in large and small blood vessels for studying molecular transport across the endothelial monolayer. The device builds upon previously demonstrated integrated microfluidic loop design by: (a) introducing nanoscale pores in the substrate membrane to enable transmembrane molecular transport, (b) transforming the substrate membrane into a nanofibrous matrix for 3D smooth muscle cell (SMC) tissue culture, (c) integrating electrospinning fabrication methods, (d) engineering an invertible sandwich cell culture device architecture, and (e) devising a healthy co-culture mechanism for human arterial endothelial cell (HAEC) monolayer and multiple layers of human smooth muscle cells (HSMC) to accurately mimic arterial anatomy. Structural and mechanical characterization was conducted using confocal microscopy, SEM, stress/strain analysis, and infrared spectroscopy. Transport was characterized using FITC-Dextran hydraulic permeability protocol. Structure and transport characterization successfully demonstrate device viability as a physiologically relevant arterial mimic for testing transendothelial transport. Thus, our lab-on-a-brane provides a highly effective and efficient, yet considerably inexpensive, physiologically relevant alternative for pharmacokinetic evaluation; possibly reducing animals used in pre-clinical testing, clinical trials cost from false starts, and time-to-market. Furthermore, this platform can be easily configured for testing targeted therapeutic delivery and in multiple simultaneous arrays for personalized and precision medicine applications.
Sumboja, Afriyanti; Liu, Jiawei; Zheng, Wesley Guangyuan; Zong, Yun; Zhang, Hua; Liu, Zhaolin
2018-06-27
Compatible energy storage devices that are able to withstand various mechanical deformations, while delivering their intended functions, are required in wearable technologies. This imposes constraints on the structural designs, materials selection, and miniaturization of the cells. To date, extensive efforts have been dedicated towards developing electrochemical energy storage devices for wearables, with a focus on incorporation of shape-conformable materials into mechanically robust designs that can be worn on the human body. In this review, we highlight the quantified performances of reported wearable electrochemical energy storage devices, as well as their micro-sized counterparts under specific mechanical deformations, which can be used as the benchmark for future studies in this field. A general introduction to the wearable technology, the development of the selection and synthesis of active materials, cell design approaches and device fabrications are discussed. It is followed by challenges and outlook toward the practical use of electrochemical energy storage devices for wearable applications.
NASA Astrophysics Data System (ADS)
Liu, Yuxin; Huang, Zhitong; Li, Wei; Ji, Yuefeng
2016-03-01
Various patterns of device-to-device (D2D) communication, from Bluetooth to Wi-Fi Direct, are emerging due to the increasing requirements of information sharing between mobile terminals. This paper presents an innovative pattern named device-to-device visible light communication (D2D-VLC) to alleviate the growing traffic problem. However, the occlusion problem is a difficulty in D2D-VLC. This paper proposes a game theory-based solution in which the best-response dynamics and best-response strategies are used to realize a mode-cooperative selection mechanism. This mechanism uses system capacity as the utility function to optimize system performance and selects the optimal communication mode for each active user from three candidate modes. Moreover, the simulation and experimental results show that the mechanism can attain a significant improvement in terms of effectiveness and energy saving compared with the cases where the users communicate via only the fixed transceivers (light-emitting diode and photo diode) or via only D2D.
Statistical approach for selection of biologically informative genes.
Das, Samarendra; Rai, Anil; Mishra, D C; Rai, Shesh N
2018-05-20
Selection of informative genes from high dimensional gene expression data has emerged as an important research area in genomics. Many gene selection techniques have been proposed so far are either based on relevancy or redundancy measure. Further, the performance of these techniques has been adjudged through post selection classification accuracy computed through a classifier using the selected genes. This performance metric may be statistically sound but may not be biologically relevant. A statistical approach, i.e. Boot-MRMR, was proposed based on a composite measure of maximum relevance and minimum redundancy, which is both statistically sound and biologically relevant for informative gene selection. For comparative evaluation of the proposed approach, we developed two biological sufficient criteria, i.e. Gene Set Enrichment with QTL (GSEQ) and biological similarity score based on Gene Ontology (GO). Further, a systematic and rigorous evaluation of the proposed technique with 12 existing gene selection techniques was carried out using five gene expression datasets. This evaluation was based on a broad spectrum of statistically sound (e.g. subject classification) and biological relevant (based on QTL and GO) criteria under a multiple criteria decision-making framework. The performance analysis showed that the proposed technique selects informative genes which are more biologically relevant. The proposed technique is also found to be quite competitive with the existing techniques with respect to subject classification and computational time. Our results also showed that under the multiple criteria decision-making setup, the proposed technique is best for informative gene selection over the available alternatives. Based on the proposed approach, an R Package, i.e. BootMRMR has been developed and available at https://cran.r-project.org/web/packages/BootMRMR. This study will provide a practical guide to select statistical techniques for selecting informative genes from high dimensional expression data for breeding and system biology studies. Published by Elsevier B.V.
77 FR 54912 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... prepaid card transactions, credit card transactions, mobile payments, and transactions involving third... a remote scanner attached to a PC or point-of-sale device, smartphone or other mobile device, or ATM... mobile payments, including the number and value of relevant bill pay transactions and person-to- person...
GUIDELINES FOR TRAINING SITUATION ANALYSIS (TSA). FINAL REPORT.
ERIC Educational Resources Information Center
CHENZOFF, ANDREW P.; FOLLEY, JOHN D., JR.
THESE GUIDELINES REPRESENT A TEXTBOOK FOR INSTRUCTION IN THREE PHASES OF TRAINING SITUATION ANALYSIS (TSA), A STANDARDIZED PROCEDURE DEVELOPED BY THE NAVAL TRAINING DEVICE CENTER FOR SYSTEMATICALLY GATHERING AND INTERPRETING THE INFORMATION RELEVANT TO THE PLANNING OF TRAINING AND TRAINING DEVICES. THREE PHASES OF TSA ARE DESCRIBED IN…
A Novel Disintegration Tester for Solid Dosage Forms Enabling Adjustable Hydrodynamics.
Kindgen, Sarah; Rach, Regine; Nawroth, Thomas; Abrahamsson, Bertil; Langguth, Peter
2016-08-01
A modified in vitro disintegration test device was designed that enables the investigation of the influence of hydrodynamic conditions on disintegration of solid oral dosage forms. The device represents an improved derivative of the compendial PhEur/USP disintegration test device. By the application of a computerized numerical control, a variety of physiologically relevant moving velocities and profiles can be applied. With the help of computational fluid dynamics, the hydrodynamic and mechanical forces present in the probe chamber were characterized for a variety of device moving speeds. Furthermore, a proof of concept study aimed at the investigation of the influence of hydrodynamic conditions on disintegration times of immediate release tablets. The experiments demonstrated the relevance of hydrodynamics for tablet disintegration, especially in media simulating the fasted state. Disintegration times increased with decreasing moving velocity. A correlation between experimentally determined disintegration times and computational fluid dynamics predicted shear stress on tablet surface was established. In conclusion, the modified disintegration test device is a valuable tool for biorelevant in vitro disintegration testing of solid oral dosage forms. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bajpai, Ritu
The motivation behind this work has been to address two of the most challenging issues posed to semiconductor gas sensors--- tuning the device selectivity and sensitivity to a wide variety of gases. In a chemiresistor type nanowire sensor, the sensitivity and selectivity depend on the interaction of different chemical analytes with the nanowire surface. Constrained by the surface properties of the nanowire material, most nanowire sensors can detect only specific type of analytes. In order to make a nano-sensor array for a wide range of analytes, there is a need to tune the device sensitivity and selectivity towards different chemicals. Employing the inherent advantages of nanostructure based sensing such as large surface area, miniature size, low power consumption, and nmol/mol (ppb) sensitivity, an attempt has been made to propose a device with tunable selectivity and sensitivity. The idea proposed in this work is to functionalize GaN nanowires which have relatively inactive surface properties (i.e., with no chemiresistive sensitivity to different classes of organic vapors), with analyte dependent active metal oxides. The selectivity of the sensor devices is controlled independent of the surface properties of the nanowire itself. It is the surface properties of the functionalizing metal oxides which determine the selectivity of these sensors. Further facilitated by the proposed fabrication technique, these sensors can be easily tuned to detect different gases. The prototype developed in this work is that of a UV assisted alcohol sensor using GaN nanowires functionalized with ZnO and SnO2 nanoparticles. As opposed to the widely demonstrated metal oxide based sensors assisted by elevated temperature, the operation of photoconductive semiconductor sensor devices such as those fabricated in this work, can also be assisted by UV illumination at room temperature. Temperature assisted sensing requires an integrated on-chip heater, which could impose constraints on the device fabrication process conditions. Additionally, light assisted sensing can be employed to tailor device response towards an analyte as demonstrated in this work. Therefore, there are two control knobs available for these sensor devices which are independent of the nanowire surface properties: i) sensor selectivity, regulated by the nanoparticle material selection ii) percentage response, tuned by the intensity of the incident light. Due to the small magnitude of device operating current and sensor activation at low illumination intensity (375 nW/cm2 at 365 nm wavelength has been used in this work), these sensors have low power consumption which makes them suitable for portable battery assisted operation. A fabrication recipe for freely suspended two-terminal nanowire devices has been developed. The deposition of nanoparticles was performed using the sputter deposition technique. A change in device current was observed when the device was exposed to alcohol vapors (methanol, ethanol, propanol, and butanol) at room temperature under 215 nm--400 nm UV illumination at 365 nm wavelength. The sensor reproducibly responded to a wide range of alcohol vapor concentrations, from 5000 mumol/mol (ppm) down to 200 nmol/mol (ppb) in air. Notably, the devices show low sensitivity to acetone and hexane, which allows them to selectively detect the alcohol vapors mixed with these two common volatile organic compounds (VOCs). The sensor response was not observed without UV excitation. To make a simplified quantitative and qualitative study of the sensitivity variation with variation of light intensity, the behavior of ZnO nanowire sensor devices was investigated in addition to the hybrid metal-oxide nanoparticle/GaN nanowire devices. With an increase in the light intensity, a corresponding increase in the device sensitivity was observed. In addition to the proposed sensor fabrication technique being a highly suitable candidate for making nano-sensor arrays for detection of a wide range of gases, the alcohol sensors fabricated in this work have many practical applications such as monitoring air quality, and testing the blood alcohol content (BAC) for impaired drivers.
ERIC Educational Resources Information Center
McIntyre, Patrick Joseph
The purpose of this study was to determine the relative effectiveness of three different types of visual devices in an instructional program designed to teach an understanding of selected theoretical science concepts to elementary school children. The visual devices were prepared using Bruner's three modes of representation (enactive, iconic, and…
Solid-state energy storage module employing integrated interconnect board
Rouillard, Jean; Comte, Christophe; Daigle, Dominik; Hagen, Ronald A.; Knudson, Orlin B.; Morin, Andre; Ranger, Michel; Ross, Guy; Rouillard, Roger; St-Germain, Philippe; Sudano, Anthony; Turgeon, Thomas A.
2004-09-28
An electrochemical energy storage device includes a number of solid-state thin-film electrochemical cells which are selectively interconnected in series or parallel through use of an integrated interconnect board. The interconnect board is typically disposed within a sealed housing which also houses the electrochemical cells, and includes a first contact and a second contact respectively coupled to first and second power terminals of the energy storage device. The interconnect board advantageously provides for selective series or parallel connectivity with the electrochemical cells, irrespective of electrochemical cell position within the housing. Fuses and various electrical and electro-mechanical devices, such as bypass, equalization, and communication devices for example, may also be mounted to the interconnect board and selectively connected to the electrochemical cells.
Coherent Structures in Plasmas Relevant to Electric Propulsion
2016-06-24
AFRL-AFOSR-VA-TR-2016-0229 Coherent Structures in Plasmas Relevant to Electric Propulsion Mark Cappelli LELAND STANFORD JUNIOR UNIV CA Final Report...TITLE AND SUBTITLE Coherent Structures in Plasmas Relevant to Electric Propulsion 5a. CONTRACT NUMBER N/A 5b. GRANT NUMBER FA9550-14-1-0017 5c...to propulsion devices through experimental, theoretical, and numerical studies. 15. SUBJECT TERMS Plasma instabilities in magnetized discharges
Solid-state energy storage module employing integrated interconnect board
Rouillard, Jean; Comte, Christophe; Daigle, Dominik; Hagen, Ronald A.; Knudson, Orlin B.; Morin, Andre; Ranger, Michel; Ross, Guy; Rouillard, Roger; St-Germain, Philippe; Sudano, Anthony; Turgeon, Thomas A.
2000-01-01
The present invention is directed to an improved electrochemical energy storage device. The electrochemical energy storage device includes a number of solid-state, thin-film electrochemical cells which are selectively interconnected in series or parallel through use of an integrated interconnect board. The interconnect board is typically disposed within a sealed housing which also houses the electrochemical cells, and includes a first contact and a second contact respectively coupled to first and second power terminals of the energy storage device. The interconnect board advantageously provides for selective series or parallel connectivity with the electrochemical cells, irrespective of electrochemical cell position within the housing. In one embodiment, a sheet of conductive material is processed by employing a known milling, stamping, or chemical etching technique to include a connection pattern which provides for flexible and selective interconnecting of individual electrochemical cells within the housing, which may be a hermetically sealed housing. Fuses and various electrical and electro-mechanical devices, such as bypass, equalization, and communication devices for example, may also be mounted to the interconnect board and selectively connected to the electrochemical cells.
NASA Astrophysics Data System (ADS)
Aluguri, R.; Kumar, D.; Simanjuntak, F. M.; Tseng, T.-Y.
2017-09-01
A bipolar transistor selector was connected in series with a resistive switching memory device to study its memory characteristics for its application in cross bar array memory. The metal oxide based p-n-p bipolar transistor selector indicated good selectivity of about 104 with high retention and long endurance showing its usefulness in cross bar RRAM devices. Zener tunneling is found to be the main conduction phenomena for obtaining high selectivity. 1BT-1R device demonstrated good memory characteristics with non-linearity of 2 orders, selectivity of about 2 orders and long retention characteristics of more than 105 sec. One bit-line pull-up scheme shows that a 650 kb cross bar array made with this 1BT1R devices works well with more than 10 % read margin proving its ability in future memory technology application.
Goto, Nobuo; Miyazaki, Yasumitsu
2014-06-01
Optical switching of high-bit-rate quadrature-phase-shift-keying (QPSK) pulse trains using collinear acousto-optic (AO) devices is theoretically discussed. Since the collinear AO devices have wavelength selectivity, the switched optical pulse trains suffer from distortion when the bandwidth of the pulse train is comparable to the pass bandwidth of the AO device. As the AO device, a sidelobe-suppressed device with a tapered surface-acoustic-wave (SAW) waveguide and a Butterworth-type filter device with a lossy SAW directional coupler are considered. Phase distortion of optical pulse trains at 40 to 100 Gsymbols/s in QPSK format is numerically analyzed. Bit-error-rate performance with additive Gaussian noise is also evaluated by the Monte Carlo method.
An electrochemical sensor device for measuring blood ammonia at the point of care.
Brannelly, N T; Killard, A J
2017-05-15
The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r 2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, p<0.0001) between both methods (n =3). When stored under desiccation, devices displayed minimal variation over time (0.64%) with respect to their impedance in air (n =12) and could be stored in desiccant for at least five months. Copyright © 2017 Elsevier B.V. All rights reserved.
Torres, Juan C.; Vergaz, Ricardo; Barrios, David; Sánchez-Pena, José Manuel; Viñuales, Ana; Grande, Hans Jürgen; Cabañero, Germán
2014-01-01
A series of polymer dispersed liquid crystal devices using glass substrates have been fabricated and investigated focusing on their electrical properties. The devices have been studied in terms of impedance as a function of frequency. An electric equivalent circuit has been proposed, including the influence of the temperature on the elements into it. In addition, a relevant effect of temperature on electrical measurements has been observed. PMID:28788632
Wiechmann, Warren; Kwan, Daniel; Bokarius, Andrew; Toohey, Shannon L
2016-03-01
The use of personal mobile devices in the medical field has grown quickly, and a large proportion of physicians use their mobile devices as an immediate resource for clinical decision-making, prescription information and other medical information. The iTunes App Store (Apple, Inc.) contains approximately 20,000 apps in its "Medical" category, providing a robust repository of resources for clinicians; however, this represents only 2% of the entire App Store. The App Store does not have strict criteria for identifying content specific to practicing physicians, making the identification of clinically relevant content difficult. The objective of this study is to quantify the characteristics of existing medical applications in the iTunes App Store that could be used by emergency physicians, residents, or medical students. We found applications related to emergency medicine (EM) by searching the iTunes App Store for 21 terms representing core content areas of EM, such as "emergency medicine," "critical care," "orthopedics," and "procedures." Two physicians independently reviewed descriptions of these applications in the App Store and categorized each as the following: Clinically Relevant, Book/Published Source, Non-English, Study Tools, or Not Relevant. A third physician reviewer resolved disagreements about categorization. Descriptive statistics were calculated. We found a total of 7,699 apps from the 21 search terms, of which 17.8% were clinical, 9.6% were based on a book or published source, 1.6% were non-English, 0.7% were clinically relevant patient education resources, and 4.8% were study tools. Most significantly, 64.9% were considered not relevant to medical professionals. Clinically relevant apps make up approximately 6.9% of the App Store's "Medical" Category and 0.1% of the overall App Store. Clinically relevant apps represent only a small percentage (6.9%) of the total App volume within the Medical section of the App Store. Without a structured search-and-evaluation strategy, it may be difficult for the casual user to identify this potentially useful content. Given the increasing adoption of devices in healthcare, national EM associations should consider curating these resources for their members.
Digital frequency-offset detector
NASA Technical Reports Server (NTRS)
Bogart, R. W.; Juengst, M. J.
1977-01-01
Simple, low-cost device with designer-selectable tolerances provides accurate frequency comparison with minimal circuitry and ease of adjustment. Warning alerts if frequencies being compared fall outside selected tolerance. Device can be applied to any electronic system where accurate timing or frequency control is important.
The Steerable Microcatheter: A New Device for Selective Catheterisation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soyama, Takeshi; Yoshida, Daisuke; Sakuhara, Yusuke, E-mail: yusaku@med.hokudai.ac.jp
The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.
Selectively-etched nanochannel electrophoretic and electrochemical devices
Surh, Michael P.; Wilson, William D.; Barbee, Jr., Troy W.; Lane, Stephen M.
2004-11-16
Nanochannel electrophoretic and electrochemical devices having selectively-etched nanolaminates located in the fluid transport channel. The normally flat surfaces of the nanolaminate having exposed conductive (metal) stripes are selectively-etched to form trenches and baffles. The modifications of the prior utilized flat exposed surfaces increase the amount of exposed metal to facilitate electrochemical redox reaction or control the exposure of the metal surfaces to analytes of large size. These etched areas variously increase the sensitivity of electrochemical detection devices to low concentrations of analyte, improve the plug flow characteristic of the channel, and allow additional discrimination of the colloidal particles during cyclic voltammetry.
Selectively-etched nanochannel electrophoretic and electrochemical devices
Surh, Michael P [Livermore, CA; Wilson, William D [Pleasanton, CA; Barbee, Jr., Troy W.; Lane, Stephen M [Oakland, CA
2006-06-27
Nanochannel electrophoretic and electrochemical devices having selectively-etched nanolaminates located in the fluid transport channel. The normally flat surfaces of the nanolaminate having exposed conductive (metal) stripes are selectively-etched to form trenches and baffles. The modifications of the prior utilized flat exposed surfaces increase the amount of exposed metal to facilitate electrochemical redox reaction or control the exposure of the metal surfaces to analytes of large size. These etched areas variously increase the sensitivity of electrochemical detection devices to low concentrations of analyte, improve the plug flow characteristic of the channel, and allow additional discrimination of the colloidal particles during cyclic voltammetry.
Hollow - cathode electrode for high-power, high-pressure discharge devices
Chang, Jim J.; Alger, Terry W.
1995-01-01
Several different cold cathode configurations for a gas discharge device each having a plurality of grooves of selected spacing, depth and width to improve the emission of electrons in a gas discharge device. Each of the cold cathode configurations can be machined from a single piece of a selected material. Several of the configurations can be assembled with individual elements which is easily seen from the various figures.
Improved selectivity from a wavelength addressable device for wireless stimulation of neural tissue
Seymour, Elif Ç.; Freedman, David S.; Gökkavas, Mutlu; Özbay, Ekmel; Sahin, Mesut; Ünlü, M. Selim
2014-01-01
Electrical neural stimulation with micro electrodes is a promising technique for restoring lost functions in the central nervous system as a result of injury or disease. One of the problems related to current neural stimulators is the tissue response due to the connecting wires and the presence of a rigid electrode inside soft neural tissue. We have developed a novel, optically activated, microscale photovoltaic neurostimulator based on a custom layered compound semiconductor heterostructure that is both wireless and has a comparatively small volume (<0.01 mm3). Optical activation provides a wireless means of energy transfer to the neurostimulator, eliminating wires and the associated complications. This neurostimulator was shown to evoke action potentials and a functional motor response in the rat spinal cord. In this work, we extend our design to include wavelength selectivity and thus allowing independent activation of devices. As a proof of concept, we fabricated two different microscale devices with different spectral responsivities in the near-infrared region. We assessed the improved addressability of individual devices via wavelength selectivity as compared to spatial selectivity alone through on-bench optical measurements of the devices in combination with an in vivo light intensity profile in the rat cortex obtained in a previous study. We show that wavelength selectivity improves the individual addressability of the floating stimulators, thus increasing the number of devices that can be implanted in close proximity to each other. PMID:24600390
SGEM Hot Off the Press: ultrasound during critical care simulation: a randomized crossover study.
McKenna, Paul; Thoma, Brent; Milne, Ken; Bond, Chris
2017-01-01
As part of the Canadian Journal of Emergency Medicine's (CJEM) developing social media strategy, 1 we are collaborating with the Skeptics' Guide to Emergency Medicine (SGEM) to summarize and critically appraise the current emergency medicine (EM) literature using evidence-based medicine principles. In the "Hot Off the Press" series, we select original research manuscripts published in CJEM to be featured on the SGEM website/podcast 2 and discussed by the study authors and the online EM community. A similar collaboration is underway between the SGEM and Academic Emergency Medicine. What follows is a summary of the selected article the immediate post-publication synthesis from the SGEM podcast, commentary by the first author, and the subsequent discussion from the SGEM blog and other social media. Through this series, we hope to enhance the value, accessibility, and application of important, clinically relevant EM research. In this, the third SGEM HOP hosted collaboratively with CJEM, we discuss Olszynski et al.'s randomized crossover study evaluating the use of ultrasound simulator devices during critical care simulation. 3.
Santos, Rui; Pombo, Nuno; Flórez-Revuelta, Francisco
2018-01-01
An increase in the accuracy of identification of Activities of Daily Living (ADL) is very important for different goals of Enhanced Living Environments and for Ambient Assisted Living (AAL) tasks. This increase may be achieved through identification of the surrounding environment. Although this is usually used to identify the location, ADL recognition can be improved with the identification of the sound in that particular environment. This paper reviews audio fingerprinting techniques that can be used with the acoustic data acquired from mobile devices. A comprehensive literature search was conducted in order to identify relevant English language works aimed at the identification of the environment of ADLs using data acquired with mobile devices, published between 2002 and 2017. In total, 40 studies were analyzed and selected from 115 citations. The results highlight several audio fingerprinting techniques, including Modified discrete cosine transform (MDCT), Mel-frequency cepstrum coefficients (MFCC), Principal Component Analysis (PCA), Fast Fourier Transform (FFT), Gaussian mixture models (GMM), likelihood estimation, logarithmic moduled complex lapped transform (LMCLT), support vector machine (SVM), constant Q transform (CQT), symmetric pairwise boosting (SPB), Philips robust hash (PRH), linear discriminant analysis (LDA) and discrete cosine transform (DCT). PMID:29315232
Developments in SPR Fragment Screening.
Chavanieu, Alain; Pugnière, Martine
2016-01-01
Fragment-based approaches have played an increasing role alongside high-throughput screening in drug discovery for 15 years. The label-free biosensor technology based on surface plasmon resonance (SPR) is now sensitive and informative enough to serve during primary screens and validation steps. In this review, the authors discuss the role of SPR in fragment screening. After a brief description of the underlying principles of the technique and main device developments, they evaluate the advantages and adaptations of SPR for fragment-based drug discovery. SPR can also be applied to challenging targets such as membrane receptors and enzymes. The high-level of immobilization of the protein target and its stability are key points for a relevant screening that can be optimized using oriented immobilized proteins and regenerable sensors. Furthermore, to decrease the rate of false negatives, a selectivity test may be performed in parallel on the main target bearing the binding site mutated or blocked with a low-off-rate ligand. Fragment-based drug design, integrated in a rational workflow led by SPR, will thus have a predominant role for the next wave of drug discovery which could be greatly enhanced by new improvements in SPR devices.
Multiplexed Electrochemical Immunosensors for Clinical Biomarkers
Yáñez-Sedeño, Paloma; Campuzano, Susana; Pingarrón, José M.
2017-01-01
Management and prognosis of disease requires the accurate determination of specific biomarkers indicative of normal or disease-related biological processes or responses to therapy. Moreover since multiple determinations of biomarkers have demonstrated to provide more accurate information than individual determinations to assist the clinician in prognosis and diagnosis, the detection of several clinical biomarkers by using the same analytical device hold enormous potential for early detection and personalized therapy and will simplify the diagnosis providing more information in less time. In this field, electrochemical immunosensors have demonstrated to offer interesting alternatives against conventional strategies due to their simplicity, fast response, low cost, high sensitivity and compatibility with multiplexed determination, microfabrication technology and decentralized determinations, features which made them very attractive for integration in point-of-care (POC) devices. Therefore, in this review, the relevance and current challenges of multiplexed determination of clinical biomarkers are briefly introduced, and an overview of the electrochemical immunosensing platforms developed so far for this purpose is given in order to demonstrate the great potential of these methodologies. After highlighting the main features of the selected examples, the unsolved challenges and future directions in this field are also briefly discussed. PMID:28448466
Comprehensive and critical literature review on insitu micro-sensors for application in tribology
NASA Astrophysics Data System (ADS)
Ling, Frederick F.; Wang, Ning; Murray, S. F.
1994-04-01
Two filters have been invoked in this survey of literature on sensors: (1) only those which might have relevance, direct or potential, to machinery condition sensing are included; (2) only those which might lend themselves to, presently or potentially, fiber-optical mode of information transmission are included. 190 records were selected to review from the 28,000 found using the University of Texas at Austin's U-Search and the Engineering Index, augmented by several commercial data bases, under LITERATURE ON SENSORS. Throughout, a sensor or transducer is understood to be a device that provides a usable output in response to a specific measurand; it is understood that such devices are called different names in different fields. This project has a highly restricted scope. The goal of the project concerns chemical as well as physical sensors of micro-dimension pertaining to lubricated contacts as to abrasive wear, friction, corrosive wear, cracks, micro-partile analysis, identification of surface film formation, load, miro-particle detection, position, speed, surface damage, and temperature. A research need analysis was proposed in anticipation of the aforementioned fact that few sensors in this context would be in-situ, let alone being of micro-dimension.
Arroyo Rojas Dasilva, Yadira; Kozak, Roksolana; Erni, Rolf; Rossell, Marta D
2017-05-01
The development of new electro-optical devices and the realization of novel types of transistors require a profound understanding of the structural characteristics of new semiconductor heterostructures. This article provides a concise review about structural defects which occur in semiconductor heterostructures on the basis of micro-patterned Si substrates. In particular, one- and two-dimensional crystal defects are being discussed which are due to the plastic relaxation of epitaxial strain caused by the misfit of crystal lattices. Besides a few selected examples from literature, we treat in particular crystal defects occurring in GaAs/Si, Ge/Si and β-SiC/Si structures which are studied by high-resolution annular dark-field scanning transmission electron microscopy. The relevance of this article is twofold; firstly, it should provide a collection of data which are of help for the identification and characterization of defects in cubic semiconductors by means of atomic-resolution imaging, and secondly, the experimental data shall provide a basis for advancing the understanding of device characteristics with the aid of theoretical modelling by considering the defective nature of strained semiconductor heterostructures. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, Deying
Stretchable organic electronics have emerged as interesting technologies for several applications where stretchability is considered important. The easy and low-cost deposition procedures for the fabrication of stretchable organic solar cells and organic light emitting devices reduce the overall cost for the fabrication of these devices. However, the interfacial cracks and defects at the interfaces of the devices, during fabrication, are detrimental to the performance of stretchable organic electronic devices. Also, as the devices are deformed under service conditions, it is possible for cracks to grow. Furthermore, the multilayered structures of the devices can fail due to the delamination and buckling of the layered structures. There is, therefore, a need to study the failure mechanism in the layered structures that are relevant to stretchable organic electronic devices. Hence, in this study, a combined experimental, analytical and computational approach is used to study the effects of adhesion and deformation on the failure mechanisms in structures that are relevant to stretchable electronic devices. First, the failure mechanisms are studied in stretchable inorganic electronic structures. The wrinkles and buckles are formed by the unloading of pre-stretched PDMS/Au structure, after the evaporation of nano-scale Au layers. They are then characterized using atomic force microscopy and scanning electron microscopy. Analytical models are used to determine the critical stresses for wrinkling and buckling. The interfacial cracking and film buckling that can occur are also studied using finite element simulations. The implications of the results are then discussed for the potential applications of micro-wrinkles and micro-buckles in the stretchable electronic structures and biomedical devices. Subsequently, the adhesion between bi-material pairs that are relevant to organic light emitting devices, composite organic/inorganic light emitting devices, organic bulk heterojunction solar cells, and composite organic/inorganic solar cells on flexible substrates, is measured using force microscopy (AFM) techniques. The AFM measurements are incorporated into the Derjaguin-Muller-Toporov model to calculate the adhesion energies. The implications of the results are then discussed for the design of robust organic and composite organic/inorganic electronic devices. Finally, the lamination of organic solar cells and organic light emitting devices is studied using a combination of experimental, computational, and analytical approaches. First, the effects of applied lamination force (on contact between the laminated layers) are studied using experiments and models. The crack driving forces associated with the interfacial cracks that form at the interfaces between layers (at the bi-material interfaces) are estimated along with the critical interfacial crack driving forces associated with the separation of thin films, after layer transfer. The conditions for successful lamination are predicted using a combination of experiments and models. Guidelines are developed for the lamination of low-cost organic electronic structures.
Walking towards Instrumental Appropriation of Mobile Devices. A Comparison of Studies
ERIC Educational Resources Information Center
Hernandez Serrano, Maria José; Yang, Lingling
2013-01-01
The study of instrumental appropriation is considered a relevant outstanding and productive perspective in the arena of Mobile ICT and learning. This paper seeks for the consolidation of this perspective at a theoretical and analytical level. Regarding the theoretical level, two characteristics of mobile devices--flexibility and mobility--are…
Apparatus for supplying conditioned air at a substantially constant temperature and humidity
NASA Technical Reports Server (NTRS)
Obler, H. D. (Inventor)
1980-01-01
The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.
2017-03-01
Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media.
2017-01-01
Abstract Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media. PMID:28121732
Alves, Ana Cristina de Jesus; Matsukura, Thelma Simões; Scherer, Marcia J
2017-02-01
The purpose of this study is to conduct a cross-cultural adaptation of the Assistive Technology Device Predisposition Assessment (ATD PA) for use in Brazil. The selection of the Assistive Technology Device Predisposition Assessment (ATD PA) was determined by previous literature reviews of articles published in 2014 and 2016 in six databases with the terms "assistive device" or "assistive technology" or "self-help device" combined with "evidence-based practice" or "framework" or "measurement scale" or "model and outcome assessment". This review indicated that the conceptual model of Assistive Technology (AT) most discussed in the literature was the Matching Person and Technology (MPT) model, and this finding determined the selection of ATD PA as an assessment within the MPT portfolio of measures. The procedures for cross-cultural adaptation were as follows: Equivalence of Concept, Semantic and Operational. Five experts were asked to translate 725 items and these translations were evaluated and a high level of agreement was demonstrated. The Portuguese version, Avaliação de Tecnologia Assistiva - Predisposição ao Uso - ATD PA Br, was derived from the original version in English (ATD PA). The ATD PA Br will support professionals and people with disabilities in Brazil to better select AT devices according to the clients' needs. Implications for rehabilitation Provides a systematic way of selecting assistive technology devices for the use of individuals with disabilities according to the Brazilian reality. A systematic way of selecting the assistive technology that can help decrease the abandonment of the assistive technology use. The use of the Matching Person and Technology theorical model and of the assessment ATD PA Br is essential to guide the researches and clinical practice in Brazil.
Robot-supported assessment of balance in standing and walking.
Shirota, Camila; van Asseldonk, Edwin; Matjačić, Zlatko; Vallery, Heike; Barralon, Pierre; Maggioni, Serena; Buurke, Jaap H; Veneman, Jan F
2017-08-14
Clinically useful and efficient assessment of balance during standing and walking is especially challenging in patients with neurological disorders. However, rehabilitation robots could facilitate assessment procedures and improve their clinical value. We present a short overview of balance assessment in clinical practice and in posturography. Based on this overview, we evaluate the potential use of robotic tools for such assessment. The novelty and assumed main benefits of using robots for assessment are their ability to assess 'severely affected' patients by providing assistance-as-needed, as well as to provide consistent perturbations during standing and walking while measuring the patient's reactions. We provide a classification of robotic devices on three aspects relevant to their potential application for balance assessment: 1) how the device interacts with the body, 2) in what sense the device is mobile, and 3) on what surface the person stands or walks when using the device. As examples, nine types of robotic devices are described, classified and evaluated for their suitability for balance assessment. Two example cases of robotic assessments based on perturbations during walking are presented. We conclude that robotic devices are promising and can become useful and relevant tools for assessment of balance in patients with neurological disorders, both in research and in clinical use. Robotic assessment holds the promise to provide increasingly detailed assessment that allows to individually tailor rehabilitation training, which may eventually improve training effectiveness.
Taming Disruptive Technologies, or How To Remain Relevant in the Digital Age.
ERIC Educational Resources Information Center
Blackwell, Philip
2001-01-01
Discusses electronic books as a disruptive technology, that is, a technology that has appeal to its users but upsets the traditional models. Highlights include a history of print technology; types of electronic books; reader devices; stakeholders, including users, librarians, and publishers; and how vendors can remain relevant. (LRW)
Bix, Laura; Seo, Do Chan; Ladoni, Moslem; Brunk, Eric; Becker, Mark W
2016-01-01
Effective standardization of medical device labels requires objective study of varied designs. Insufficient empirical evidence exists regarding how practitioners utilize and view labeling. Measure the effect of graphic elements (boxing information, grouping information, symbol use and color-coding) to optimize a label for comparison with those typical of commercial medical devices. Participants viewed 54 trials on a computer screen. Trials were comprised of two labels that were identical with regard to graphics, but differed in one aspect of information (e.g., one had latex, the other did not). Participants were instructed to select the label along a given criteria (e.g., latex containing) as quickly as possible. Dependent variables were binary (correct selection) and continuous (time to correct selection). Eighty-nine healthcare professionals were recruited at Association of Surgical Technologists (AST) conferences, and using a targeted e-mail of AST members. Symbol presence, color coding and grouping critical pieces of information all significantly improved selection rates and sped time to correct selection (α = 0.05). Conversely, when critical information was graphically boxed, probability of correct selection and time to selection were impaired (α = 0.05). Subsequently, responses from trials containing optimal treatments (color coded, critical information grouped with symbols) were compared to two labels created based on a review of those commercially available. Optimal labels yielded a significant positive benefit regarding the probability of correct choice ((P<0.0001) LSM; UCL, LCL: 97.3%; 98.4%, 95.5%)), as compared to the two labels we created based on commercial designs (92.0%; 94.7%, 87.9% and 89.8%; 93.0%, 85.3%) and time to selection. Our study provides data regarding design factors, namely: color coding, symbol use and grouping of critical information that can be used to significantly enhance the performance of medical device labels.
Attitude importance and the accumulation of attitude-relevant knowledge in memory.
Holbrook, Allyson L; Berent, Matthew K; Krosnick, Jon A; Visser, Penny S; Boninger, David S
2005-05-01
People who attach personal importance to an attitude are especially knowledgeable about the attitude object. This article tests an explanation for this relation: that importance causes the accumulation of knowledge by inspiring selective exposure to and selective elaboration of relevant information. Nine studies showed that (a) after watching televised debates between presidential candidates, viewers were better able to remember the statements made on policy issues on which they had more personally important attitudes; (b) importance motivated selective exposure and selective elaboration: Greater personal importance was associated with better memory for relevant information encountered under controlled laboratory conditions, and manipulations eliminating opportunities for selective exposure and selective elaboration eliminated the importance-memory accuracy relation; and (c) people do not use perceptions of their knowledge volume to infer how important an attitude is to them, but importance does cause knowledge accumulation.
Effectiveness of robot-assisted therapy on ankle rehabilitation – a systematic review
2013-01-01
Objective The aim of this study was to provide a systematic review of studies that investigated the effectiveness of robot-assisted therapy on ankle motor and function recovery from musculoskeletal or neurologic ankle injuries. Methods Thirteen electronic databases of articles published from January, 1980 to June, 2012 were searched using keywords ‘ankle*’, ‘robot*’, ‘rehabilitat*’ or ‘treat*’ and a free search in Google Scholar based on effects of ankle rehabilitation robots was also conducted. References listed in relevant publications were further screened. Eventually, twenty-nine articles were selected for review and they focused on effects of robot-assisted ankle rehabilitation. Results Twenty-nine studies met the inclusion criteria and a total of 164 patients and 24 healthy subjects participated in these trials. Ankle performance and gait function were the main outcome measures used to assess the therapeutic effects of robot-assisted ankle rehabilitation. The protocols and therapy treatments were varied, which made comparison among different studies difficult or impossible. Few comparative trials were conducted among different devices or control strategies. Moreover, the majority of study designs met levels of evidence that were no higher than American Academy for Cerebral Palsy (CP) and Developmental Medicine (AACPDM) level IV. Only one study used a Randomized Control Trial (RCT) approach with the evidence level being II. Conclusion All the selected studies showed improvements in terms of ankle performance or gait function after a period of robot-assisted ankle rehabilitation training. The most effective robot-assisted intervention cannot be determined due to the lack of universal evaluation criteria for various devices and control strategies. Future research into the effects of robot-assisted ankle rehabilitation should be carried out based on universal evaluation criteria, which could determine the most effective method of intervention. It is also essential to conduct trials to analyse the differences among different devices or control strategies. PMID:23517734
Hollow-cathode electrode for high-power, high-pressure discharge devices
Chang, J.J.; Alger, T.W.
1995-08-22
Several different cold cathode configurations are disclosed for a gas discharge device each having a plurality of grooves of selected spacing, depth and width to improve the emission of electrons in a gas discharge device. Each of the cold cathode configurations can be machined from a single piece of a selected material. Several of the configurations can be assembled with individual elements which is easily seen from the various figures. 8 figs.
Tachycardia detection in ICDs by Boston Scientific : Algorithms, pearls, and pitfalls.
Zanker, Norbert; Schuster, Diane; Gilkerson, James; Stein, Kenneth
2016-09-01
The aim of this study was to summarize how implantable cardioverter defibrillators (ICDs) by Boston Scientific sense, detect, discriminate rhythms, and classify episodes. Modern devices include multiple programming selections, diagnostic features, therapy options, memory functions, and device-related history features. Device operation includes logical steps from sensing, detection, discrimination, therapy delivery to history recording. The program is designed to facilitate the application of the device algorithms to the individual patient's clinical needs. Features and functions described in this article represent a selective excerpt by the authors from Boston Scientific publicly available product resources. Programming of ICDs may affect patient outcomes. Patient-adapted and optimized programming requires understanding of device operation and concepts.
6 CFR 27.225 - Site security plans.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Identify and describe how security measures selected by the facility will address the applicable risk-based... explosive devices, water-borne explosive devices, ground assault, or other modes or potential modes identified by the Department; (3) Identify and describe how security measures selected and utilized by the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gubbiotti, G.; Tacchi, S.; Montoncello, F.
2015-06-29
The Brillouin light scattering technique has been exploited to study the angle-resolved spin wave band diagrams of squared Permalloy antidot lattice. Frequency dispersion of spin waves has been measured for a set of fixed wave vector magnitudes, while varying the wave vector in-plane orientation with respect to the applied magnetic field. The magnonic band gap between the two most dispersive modes exhibits a minimum value at an angular position, which exclusively depends on the product between the selected wave vector magnitude and the lattice constant of the array. The experimental data are in very good agreement with predictions obtained bymore » dynamical matrix method calculations. The presented results are relevant for magnonic devices where the antidot lattice, acting as a diffraction grating, is exploited to achieve multidirectional spin wave emission.« less
Evaluating polymeric biomaterial–environment interfaces by Langmuir monolayer techniques
Schöne, Anne-Christin; Roch, Toralf; Schulz, Burkhard
2017-01-01
Polymeric biomaterials are of specific relevance in medical and pharmaceutical applications due to their wide range of tailorable properties and functionalities. The knowledge about interactions of biomaterials with their biological environment is of crucial importance for developing highly sophisticated medical devices. To achieve optimal in vivo performance, a description at the molecular level is required to gain better understanding about the surface of synthetic materials for tailoring their properties. This is still challenging and requires the comprehensive characterization of morphological structures, polymer chain arrangements and degradation behaviour. The review discusses selected aspects for evaluating polymeric biomaterial–environment interfaces by Langmuir monolayer methods as powerful techniques for studying interfacial properties, such as morphological and degradation processes. The combination of spectroscopic, microscopic and scattering methods with the Langmuir techniques adapted to polymers can substantially improve the understanding of their in vivo behaviour. PMID:28468918
Single-electron thermal devices coupled to a mesoscopic gate
NASA Astrophysics Data System (ADS)
Sánchez, Rafael; Thierschmann, Holger; Molenkamp, Laurens W.
2017-11-01
We theoretically investigate the propagation of heat currents in a three-terminal quantum dot engine. Electron-electron interactions introduce state-dependent processes which can be resolved by energy-dependent tunneling rates. We identify the relevant transitions which define the operation of the system as a thermal transistor or a thermal diode. In the former case, thermal-induced charge fluctuations in the gate dot modify the thermal currents in the conductor with suppressed heat injection, resulting in huge amplification factors and the possible gating with arbitrarily low energy cost. In the latter case, enhanced correlations of the state-selective tunneling transitions redistribute heat flows giving high rectification coefficients and the unexpected cooling of one conductor terminal by heating the other one. We propose quantum dot arrays as a possible way to achieve the extreme tunneling asymmetries required for the different operations.
High Power Microwave Tubes: Basics and Trends, Volume 1
NASA Astrophysics Data System (ADS)
Kesari, Vishal; Basu, B. N.
2018-01-01
Our aim in this book is to present a bird's-eye view of microwave tubes (MWTs) which continue to be important despite competitive incursions from solid-state devices (SSDs). We have presented a broad and introductory survey which we hope the readers would be encouraged to read rather than going through lengthier books, and subsequently explore the field of MWTs further in selected areas of relevance to their respective interests. We hope that the present book would motivate newcomers to pursue research in MWTs and apprise them as well as decision makers of the salient features and prospects of as well as the trends of progress in MWTs. The scope of ever expanding applications of MWTs in the high power and high frequency regime will sustain and intensify the research and development in MWTs in coming years.
Transpalatal distraction for the management of maxillary constriction in pediatric patients.
Adolphs, Nicolai; Ernst, Nicole; Hoffmeister, Bodo; Raguse, Jan-Dirk
2015-01-01
The management of severe maxillary constriction can be challenging. For that purpose surgically assisted maxillary expansion by transpalatal distraction (TPD) can typically be recommended after skeletal maturity. However in selected cases bone borne transpalatal distraction devices can contribute to improve maxillary constriction considerably earlier already during mixed dentition. To assess the possibility of bone borne transpalatal distraction in pediatric patients. Clinical paper. Since 2010 TPD has been applied to six pediatric patients during mixed dentition when severe maxillary constriction was present and conventional orthodontic widening has already failed. Individually selected devices (Surgitec, Belgium) were inserted in general anaesthesia and distraction was performed according to well known parameters. Maxillary constriction could be improved in all six patients without any drawbacks by bone borne devices during mixed dentition. Skeletal conditions were obviously improved for subsequent orthodontic or orthognathic therapy without functional impairment. Follow-up is up to 36 months after device removal. Transpalatal Distraction is recommendable in selected pediatric patients if massive growth disturbance is present or has to be expected. TPD allows for individually adapted maxillary expansion by selection and positioning of appropriate devices in combination with intraoperative testing of maxillary movements and controlled bone removal.
Jackson, Jade; Rich, Anina N; Williams, Mark A; Woolgar, Alexandra
2017-02-01
Human cognition is characterized by astounding flexibility, enabling us to select appropriate information according to the objectives of our current task. A circuit of frontal and parietal brain regions, often referred to as the frontoparietal attention network or multiple-demand (MD) regions, are believed to play a fundamental role in this flexibility. There is evidence that these regions dynamically adjust their responses to selectively process information that is currently relevant for behavior, as proposed by the "adaptive coding hypothesis" [Duncan, J. An adaptive coding model of neural function in prefrontal cortex. Nature Reviews Neuroscience, 2, 820-829, 2001]. Could this provide a neural mechanism for feature-selective attention, the process by which we preferentially process one feature of a stimulus over another? We used multivariate pattern analysis of fMRI data during a perceptually challenging categorization task to investigate whether the representation of visual object features in the MD regions flexibly adjusts according to task relevance. Participants were trained to categorize visually similar novel objects along two orthogonal stimulus dimensions (length/orientation) and performed short alternating blocks in which only one of these dimensions was relevant. We found that multivoxel patterns of activation in the MD regions encoded the task-relevant distinctions more strongly than the task-irrelevant distinctions: The MD regions discriminated between stimuli of different lengths when length was relevant and between the same objects according to orientation when orientation was relevant. The data suggest a flexible neural system that adjusts its representation of visual objects to preferentially encode stimulus features that are currently relevant for behavior, providing a neural mechanism for feature-selective attention.
In Vitro Comparison of a Novel Single Probe Dual-Energy Lithotripter to Current Devices.
Carlos, Evan C; Wollin, Daniel A; Winship, Brenton B; Jiang, Ruiyang; Radvak, Daniela; Chew, Ben H; Gustafson, Michael R; Simmons, W Neal; Zhong, Pei; Preminger, Glenn M; Lipkin, Michael E
2018-06-01
The LithoClast Trilogy is a novel single probe, dual-energy lithotripter with ultrasonic (US) vibration and electromagnetic impact forces. ShockPulse and LithoClast Select are existing lithotripters that also use a combination of US and mechanical impact energies. We compared the efficacy and tip motion of these devices in an in vitro setting. Begostones, in the ratio 15:3, were used in all trials. Test groups were Trilogy, ShockPulse, Select ultrasound (US) only, and Select ultrasound with pneumatic (USP). For clearance testing, a single investigator facile with each lithotripter fragmented 10 stones per device. For drill testing, a hands-free apparatus with a submerged balance was used to apply 1 or 2 lbs of pressure on a stone in contact with the device tip. High-speed photography was used to assess Trilogy and ShockPulse's probe tip motion. Select-USP was slowest and Trilogy fastest on clearance testing (p < 0.01). On 1 lbs drill testing, Select-US was slowest (p = 0.001). At 2 lbs, ShockPulse was faster than Select US (p = 0.027), but did not significantly outpace Trilogy nor Select-USP. At either weight, there was no significant difference between Trilogy and ShockPulse. During its US function, Trilogy's maximum downward tip displacement was 0.041 mm relative to 0.0025 mm with ShockPulse. Trilogy had 0.25 mm of maximum downward displacement during its impactor function while ShockPulse had 0.01 mm. Single probe dual-energy devices, such as Trilogy and ShockPulse, represent the next generation of lithotripters. Trilogy more efficiently cleared stone than currently available devices, which could be explained by its larger probe diameter and greater downward tip displacement during both US and impactor functions.
21 CFR 888.4800 - Template for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4800 Template for clinical use. (a... purposes, such as selecting or positioning orthopedic implants or guiding the marking of tissue before...
21 CFR 888.4800 - Template for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4800 Template for clinical use. (a... purposes, such as selecting or positioning orthopedic implants or guiding the marking of tissue before...
21 CFR 888.4800 - Template for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4800 Template for clinical use. (a... purposes, such as selecting or positioning orthopedic implants or guiding the marking of tissue before...
Shot noise: from Schottky's vacuum tube to present-day quantum devices
NASA Astrophysics Data System (ADS)
Schonenberger, Christian; Oberholzer, Stefan
2004-05-01
Shot-noise in the electrical current through a 'device' is caused by random processes that determine the electron transport from source to drain. Two sources can be distinguished: on the hand, electrons may randomly emanate from the contacts (source and drain), because the relevant states in the reservoirs fluctuate. On the other hand, the transmission through the device is non-deterministic (non-classical). As we demonstrate in this article the former dominates noise in the vacuum tube, whereas the latter applies to coherent mesoscopic devices, which have been studied in great detail during the last decade.
NASA Technical Reports Server (NTRS)
McGreevy, Michael W.; Statler, Irving C.
1998-01-01
An exploratory study was conducted to identify commercial aviation incidents that are relevant to a "controlled flight into terrain" (CFIT) accident using a NASA-developed text processing method. The QUORUM method was used to rate 67820 incident narratives, virtually all of the narratives in the Aviation Safety Reporting System (ASRS) database, according to their relevance to two official reports on the crash of American Airlines Flight 965 near Cali, Colombia in December 1995. For comparison with QUORUM's ratings, three experienced ASRS analysts read the reports of the crash and independently rated the relevance of the 100 narratives that were most highly rated by QUORUM, as well as 100 narratives randomly selected from the database. Eighty-four of 100 QUORUM-selected narratives were rated as relevant to the Cali accident by one or more of the analysts. The relevant incidents involved a variety of factors, including, over-reliance on automation, confusion and changes during descent/approach, terrain avoidance, and operations in foreign airspace. In addition, the QUORUM collection of incidents was found to be significantly more relevant than the random collection.
ERIC Educational Resources Information Center
Naumann, Johannes; Salmerón, Ladislao
2016-01-01
This study investigated interactive effects of navigation and offline comprehension skill on digital reading performance. As indicators of navigation, relevant page selection and irrelevant page selection were considered. In 533 Spanish high school students aged 11-17 positive effects of offline comprehension skill and relevant page selection on…
Descemet's Stripping Automated Endothelial Keratoplasty Tissue Insertion Devices
Khan, Salman Nasir; Shiakolas, Panos S.; Mootha, Venkateswara Vinod
2015-01-01
This review study provides information regarding the construction, design, and use of six commercially available endothelial allograft insertion devices applied for Descemet's stripping automated endothelial keratoplasty (DSAEK). We also highlight issues being faced in DSAEK and discuss the methods through which medical devices such as corneal inserters may alleviate these issues. Inserter selection is of high importance in the DSAEK procedure since overcoming the learning curve associated with the use of an insertion device is a time and energy consuming process. In the present review, allograft insertion devices were compared in terms of design, construction material, insertion technique, dimensions, incision requirements and endothelial cell loss to show their relative merits and capabilities based on available data in the literature. Moreover, the advantages/disadvantages of various insertion devices used for allograft insertion in DSAEK are reviewed and compared. The information presented in this review can be utilized for better selection of an insertion device for DSAEK. PMID:27051492
NASA Technical Reports Server (NTRS)
Schwab, Andrew J. (Inventor); Aylor, James (Inventor); Hitchcock, Charles Young (Inventor); Wulf, William A. (Inventor); McKee, Sally A. (Inventor); Moyer, Stephen A. (Inventor); Klenke, Robert (Inventor)
2000-01-01
A data processing system is disclosed which comprises a data processor and memory control device for controlling the access of information from the memory. The memory control device includes temporary storage and decision ability for determining what order to execute the memory accesses. The compiler detects the requirements of the data processor and selects the data to stream to the memory control device which determines a memory access order. The order in which to access said information is selected based on the location of information stored in the memory. The information is repeatedly accessed from memory and stored in the temporary storage until all streamed information is accessed. The information is stored until required by the data processor. The selection of the order in which to access information maximizes bandwidth and decreases the retrieval time.
Solid state technology: A compilation. [on semiconductor devices
NASA Technical Reports Server (NTRS)
1973-01-01
A compilation, covering selected solid state devices developed and integrated into systems by NASA to improve performance, is presented. Data are also given on device shielding in hostile radiation environments.
NASA Astrophysics Data System (ADS)
Laudien, Robert; Schultze, Rainer; Wieser, Jochen
2010-10-01
In this contribution two analytical devices for the fast detection of security-relevant substances like narcotics and explosives are presented. One system is based on an ion trap mass spectrometer (ITMS) with single photon ionization (SPI). This soft ionization technique, unlike electron impact ionization (EI), reduces unwanted fragment ions in the mass spectra allowing the clear determination of characteristic (usually molecular) ions. Their enrichment in the ion trap and identification by tandem MS investigations (MS/MS) enables the detection of the target substances in complex matrices at low concentrations without time-consuming sample preparation. For SPI an electron beam pumped excimer light source of own fabrication (E-Lux) is used. The SPI-ITMS system was characterized by the analytical study of different drugs like cannabis, heroin, cocaine, amphetamines, and some precursors. Additionally, it was successfully tested on-site in a closed illegal drug laboratory, where low quantities of MDMA could be directly detected in samples from floors, walls and lab equipments. The second analytical system is based on an ion mobility (IM) spectrometer with resonant multiphoton ionization (REMPI). With the frequency quadrupled Nd:YAG laser (266 nm), used for ionization, a selective and sensitive detection of aromatic compounds is possible. By application of suited aromatic dopants, in addition, also non-aromatic polar compounds are accessible by ion molecule reactions like proton transfer or complex formation. Selected drug precursors could be successfully detected with this device as well, qualifying it to a lower-priced alternative or useful supplement of the SPI-ITMS system for security analysis.
ERIC Educational Resources Information Center
Hanson, Cody
2011-01-01
In 2011, cell phones and mobile devices are ubiquitous. The vast majority of Americans now own cell phones, and over half of them have mobile access to the Internet through a phone or other mobile device. For libraries to stay relevant, they must be able to offer content and services through the mobile web. In this issue of "Library Technology…
ERIC Educational Resources Information Center
Dadey, Nathan; Lyons, Susan; DePascale, Charles
2018-01-01
Evidence of comparability is generally needed whenever there are variations in the conditions of an assessment administration, including variations introduced by the administration of an assessment on multiple digital devices (e.g., tablet, laptop, desktop). This article is meant to provide a comprehensive examination of issues relevant to the…
Lawo, Vera; Fels, Janina; Oberem, Josefa; Koch, Iring
2014-10-01
Using an auditory variant of task switching, we examined the ability to intentionally switch attention in a dichotic-listening task. In our study, participants responded selectively to one of two simultaneously presented auditory number words (spoken by a female and a male, one for each ear) by categorizing its numerical magnitude. The mapping of gender (female vs. male) and ear (left vs. right) was unpredictable. The to-be-attended feature for gender or ear, respectively, was indicated by a visual selection cue prior to auditory stimulus onset. In Experiment 1, explicitly cued switches of the relevant feature dimension (e.g., from gender to ear) and switches of the relevant feature within a dimension (e.g., from male to female) occurred in an unpredictable manner. We found large performance costs when the relevant feature switched, but switches of the relevant feature dimension incurred only small additional costs. The feature-switch costs were larger in ear-relevant than in gender-relevant trials. In Experiment 2, we replicated these findings using a simplified design (i.e., only within-dimension switches with blocked dimensions). In Experiment 3, we examined preparation effects by manipulating the cueing interval and found a preparation benefit only when ear was cued. Together, our data suggest that the large part of attentional switch costs arises from reconfiguration at the level of relevant auditory features (e.g., left vs. right) rather than feature dimensions (ear vs. gender). Additionally, our findings suggest that ear-based target selection benefits more from preparation time (i.e., time to direct attention to one ear) than gender-based target selection.
A review of the physics and response models for burnout of semiconductor devices
NASA Astrophysics Data System (ADS)
Orvis, W. J.; Khanaka, G. H.; Yee, J. H.
1984-12-01
Physical mechanisms that cause semiconductor devices to fail from electrical overstress--particularly, EMP-induced electrical stress--are described in light of the current literature and the authors' own research. A major concern is the cause and effects of second breakdown phenomena in p-n junction devices. Models of failure thresholds are evaluated for their inherent errors and for their ability to represent the relevant physics. Finally, the response models that relate electromagnetic stress parameters to appropriate failure-threshold parameters are discussed.
Micromachined modulator arrays for use in free-space optical communication systems
NASA Astrophysics Data System (ADS)
Lewis, Keith L.; Ridley, Kevin D.; McNie, Mark E.; Smith, Gilbert W.; Scott, Andrew M.
2004-12-01
A summary is presented of some of the design criteria relevant to the realisation of silicon micromachined modulator arrays for use in free-space optical communication systems. Theoretical performance levels achievable are compared with values measured on experimental devices produced using a modified Multi-User MEMS Process (MUMPS). Devices capable of realising modulation rates in excess of 300 kHz are described and their optical characteristics compared with published data on devices based on multiple quantum well technology.
Measuring individual work performance: identifying and selecting indicators.
Koopmans, Linda; Bernaards, Claire M; Hildebrandt, Vincent H; de Vet, Henrica C W; van der Beek, Allard J
2014-01-01
Theoretically, individual work performance (IWP) can be divided into four dimensions: task performance, contextual performance, adaptive performance, and counterproductive work behavior. However, there is no consensus on the indicators used to measure these dimensions. This study was designed to (1) identify indicators for each dimension, (2) select the most relevant indicators, and (3) determine the relative weight of each dimension in ratings of work performance. IWP indicators were identified from multiple research disciplines, via literature, existing questionnaires, and expert interviews. Subsequently, experts selected the most relevant indicators per dimension and scored the relative weight of each dimension in ratings of IWP. In total, 128 unique indicators were identified. Twenty-three of these indicators were selected by experts as most relevant for measuring IWP. Task performance determined 36% of the work performance rating, while the other three dimensions respectively determined 22%, 20% and 21% of the rating. Notable consensus was found on relevant indicators of IWP, reducing the number from 128 to 23 relevant indicators. This provides an important step towards the development of a standardized, generic and short measurement instrument for assessing IWP.
Performance of Bulk Heterojunction Photovoltaic Devices Prepared by Airbrush Spray Deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, R.; Morfa, A.; Ferguson, A. J.
2008-01-01
We have used airbrush spray deposition to fabricate organic photovoltaic devices with an active layer composed of a blend of poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester. Working devices were prepared in ambient conditions from a variety of common organic solvents; active layers prepared from chlorobenzene exhibit improved homogeneity, resulting in narrower distributions of the relevant device parameters. Further studies on devices prepared from chlorobenzene showed that annealing at 120 C for 10 min resulted in optimum performance, and that an active layer thickness of 150 nm resulted in a maximum efficiency of 2.35% under AM1.5 illumination at 1more » sun.« less
Kjeldgaard, Peter; Lykkegaard, Jesper; Spillemose, Heidi; Ulrik, Charlotte Suppli
2017-01-01
Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV 1 and FEV 6 ) facilitates early detection of COPD in primary care. In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV 1 /FEV 6 <0.7, FEV 1 <80%pred, or clinical suspicion of COPD regardless of test result (medical doctor's [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV 1 /FVC <0.70), asthma (ΔFEV 1 ≥0.50 L), or no obstructive lung disease. A total of 2,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV 1 /FEV 6 <0.70, 382 (40%) FEV 1 <80%pred, and 57 (6%) MD decision. Following confirmative spirometry, the 949 individuals were diagnosed as having COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV 1 /FEV 6 <0.7 and in 29% based on FEV 1 ≤80%pred. Prescreening with the COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care.
The Most Cut-Resistant Neck Guard for Preventing Lacerations to the Neck
Loyd, Andre M.; Berglund, Lawrence; Twardowski, Casey P.; Stuart, Michael B.; Smith, Aynsley M.; Gaz, Daniel V.; Krause, David A.; An, Kai-Nan; Stuart, Michael J.
2017-01-01
Objective To evaluate the effectiveness of a variety of neck guard brands when contacted by a sharpened hockey skate blade. Design Analytic experimental. Setting Laboratory. Participants Neck surrogate. Interventions Forty-six samples of 14 different types of neck guards were tested on a custom-made laceration machine using a neck surrogate. Closed-cell polyethylene foam was placed between the neck surrogate and the protective device. Main Outcome Measures The effectiveness of the neck guard was evaluated by observation of the foam after the simulated slicing action of the skate blade. Two sets of tests were performed on each device sample including low and high force. For low-force tests, initial compression loads of 100, 200, and 300 N were applied between the neck surrogate for each of 2 orientations of the blade at 45 and 90 degrees. For high-force tests, representing a more severe simulation, the applied load was increased to 600 N and a blade angle fixed at 45 degrees. All tests were performed at a blade speed of 5 m/s. Results Only 1 product, the Bauer N7 Nectech, failed during the 300-N compression tests. All of the neck guards failed during 600-N test condition except for the Skate Armor device and 1 of the 3 Reebok 11K devices. Conclusions A skate blade angle of 45 degrees increased the likelihood of a neck laceration compared with a skate blade angle of 90 degrees due to decreased contact area. Damage to the neck guard is not an indicator of the cut resistance of a neck guard. Neck protectors with Spectra fibers were the most cut resistant. Clinical Relevance The study provides data for the selection of neck guards and neck guard materials that can reduce lacerations to the neck. PMID:24949830
Neural evidence reveals the rapid effects of reward history on selective attention.
MacLean, Mary H; Giesbrecht, Barry
2015-05-05
Selective attention is often framed as being primarily driven by two factors: task-relevance and physical salience. However, factors like selection and reward history, which are neither currently task-relevant nor physically salient, can reliably and persistently influence visual selective attention. The current study investigated the nature of the persistent effects of irrelevant, physically non-salient, reward-associated features. These features affected one of the earliest reliable neural indicators of visual selective attention in humans, the P1 event-related potential, measured one week after the reward associations were learned. However, the effects of reward history were moderated by current task demands. The modulation of visually evoked activity supports the hypothesis that reward history influences the innate salience of reward associated features, such that even when no longer relevant, nor physically salient, these features have a rapid, persistent, and robust effect on early visual selective attention. Copyright © 2015 Elsevier B.V. All rights reserved.
Highly Multiplexed RNA Aptamer Selection using a Microplate-based Microcolumn Device.
Reinholt, Sarah J; Ozer, Abdullah; Lis, John T; Craighead, Harold G
2016-07-19
We describe a multiplexed RNA aptamer selection to 19 different targets simultaneously using a microcolumn-based device, MEDUSA (Microplate-based Enrichment Device Used for the Selection of Aptamers), as well as a modified selection process, that significantly reduce the time and reagents needed for selections. We exploited MEDUSA's reconfigurable design between parallel and serially-connected microcolumns to enable the use of just 2 aliquots of starting library, and its 96-well microplate compatibility to enable the continued use of high-throughput techniques in downstream processes. Our modified selection protocol allowed us to perform the equivalent of a 10-cycle selection in the time it takes for 4 traditional selection cycles. Several aptamers were discovered with nanomolar dissociation constants. Furthermore, aptamers were identified that not only bound with high affinity, but also acted as inhibitors to significantly reduce the activity of their target protein, mouse decapping exoribonuclease (DXO). The aptamers resisted DXO's exoribonuclease activity, and in studies monitoring DXO's degradation of a 30-nucleotide substrate, less than 1 μM of aptamer demonstrated significant inhibition of DXO activity. This aptamer selection method using MEDUSA helps to overcome some of the major challenges with traditional aptamer selections, and provides a platform for high-throughput selections that lends itself to process automation.
Valizade Hasanloei, Mohammad Amin; Sheikhpour, Razieh; Sarram, Mehdi Agha; Sheikhpour, Elnaz; Sharifi, Hamdollah
2018-02-01
Quantitative structure-activity relationship (QSAR) is an effective computational technique for drug design that relates the chemical structures of compounds to their biological activities. Feature selection is an important step in QSAR based drug design to select the most relevant descriptors. One of the most popular feature selection methods for classification problems is Fisher score which aim is to minimize the within-class distance and maximize the between-class distance. In this study, the properties of Fisher criterion were extended for QSAR models to define the new distance metrics based on the continuous activity values of compounds with known activities. Then, a semi-supervised feature selection method was proposed based on the combination of Fisher and Laplacian criteria which exploits both compounds with known and unknown activities to select the relevant descriptors. To demonstrate the efficiency of the proposed semi-supervised feature selection method in selecting the relevant descriptors, we applied the method and other feature selection methods on three QSAR data sets such as serine/threonine-protein kinase PLK3 inhibitors, ROCK inhibitors and phenol compounds. The results demonstrated that the QSAR models built on the selected descriptors by the proposed semi-supervised method have better performance than other models. This indicates the efficiency of the proposed method in selecting the relevant descriptors using the compounds with known and unknown activities. The results of this study showed that the compounds with known and unknown activities can be helpful to improve the performance of the combined Fisher and Laplacian based feature selection methods.
NASA Astrophysics Data System (ADS)
Valizade Hasanloei, Mohammad Amin; Sheikhpour, Razieh; Sarram, Mehdi Agha; Sheikhpour, Elnaz; Sharifi, Hamdollah
2018-02-01
Quantitative structure-activity relationship (QSAR) is an effective computational technique for drug design that relates the chemical structures of compounds to their biological activities. Feature selection is an important step in QSAR based drug design to select the most relevant descriptors. One of the most popular feature selection methods for classification problems is Fisher score which aim is to minimize the within-class distance and maximize the between-class distance. In this study, the properties of Fisher criterion were extended for QSAR models to define the new distance metrics based on the continuous activity values of compounds with known activities. Then, a semi-supervised feature selection method was proposed based on the combination of Fisher and Laplacian criteria which exploits both compounds with known and unknown activities to select the relevant descriptors. To demonstrate the efficiency of the proposed semi-supervised feature selection method in selecting the relevant descriptors, we applied the method and other feature selection methods on three QSAR data sets such as serine/threonine-protein kinase PLK3 inhibitors, ROCK inhibitors and phenol compounds. The results demonstrated that the QSAR models built on the selected descriptors by the proposed semi-supervised method have better performance than other models. This indicates the efficiency of the proposed method in selecting the relevant descriptors using the compounds with known and unknown activities. The results of this study showed that the compounds with known and unknown activities can be helpful to improve the performance of the combined Fisher and Laplacian based feature selection methods.
34 CFR 303.13 - Early intervention services.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Assistive technology device and service are defined as follows: (i) Assistive technology device means any... device. (ii) Assistive technology service means any service that directly assists an infant or toddler with a disability in the selection, acquisition, or use of an assistive technology device. The term...
34 CFR 303.13 - Early intervention services.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Assistive technology device and service are defined as follows: (i) Assistive technology device means any... device. (ii) Assistive technology service means any service that directly assists an infant or toddler with a disability in the selection, acquisition, or use of an assistive technology device. The term...
34 CFR 303.13 - Early intervention services.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Assistive technology device and service are defined as follows: (i) Assistive technology device means any... device. (ii) Assistive technology service means any service that directly assists an infant or toddler with a disability in the selection, acquisition, or use of an assistive technology device. The term...
Relevance Theory and the Language of Advertising. CLS Occasional Paper No. 31.
ERIC Educational Resources Information Center
Byrne, Barbara
Relevance theory, the premise that a hearer will make the effort to process a communication if he or she feels it will alter or enrich his/her cognitive environment, can be useful for increasing the effectiveness of advertising communication. It is particularly helpful for analyzing and improving the effectiveness of the creative devices often…
NASA Technical Reports Server (NTRS)
Loftus, David J. (Inventor)
2006-01-01
System and method for enclosing cells and/or tissue, for purposes of growth, cell differentiation, suppression of cell differentiation, biological processing and/or transplantation of cells and tissues (biological inserts), and for secretion, sensing and monitoring of selected chemical substances and activation of gene expression of biological inserts implanted into a human body. Selected cells and/or tissue are enveloped in a "cage" that is primarily carbon nanotube Bucky paper, with a selected thickness and porosity. Optionally, selected functional groups, proteins and/or peptides are attached to the carbon nanotube cage, or included within the cage, to enhance the growth and/or differentiation of the cells and/or tissue, to select for certain cellular sub-populations, to optimize certain functions of the cells and/or tissue and/or to optimize the passage of chemicals across the cage surface(s). A cage system is also used as an immuns shield and to control operation of a nano-device or macroscopic device, located within the cage, to provide or transform a selected chemical and/or a selected signal.
Needs assessment for simulation training in neuroendoscopy: a Canadian national survey.
Haji, Faizal A; Dubrowski, Adam; Drake, James; de Ribaupierre, Sandrine
2013-02-01
In recent years, dramatic changes in surgical education have increased interest in simulation-based training for complex surgical skills. This is particularly true for endoscopic third ventriculostomy (ETV), given the potential for serious intraoperative errors arising from surgical inexperience. However, prior to simulator development, a thorough assessment of training needs is essential to ensure development of educationally relevant platforms. The purpose of this study was to conduct a national needs assessment addressing specific goals of instruction, to guide development of simulation platforms, training curricula, and assessment metrics for ETV. Canadian neurosurgeons performing ETV were invited to participate in a structured online questionnaire regarding the procedural steps for ETV, the frequency and significance of intraoperative errors committed while learning the technique, and simulation training modules of greatest potential educational benefit. Descriptive data analysis was completed for both quantitative and qualitative responses. Thirty-two (55.2%) of 58 surgeons completed the survey. All believed that virtual reality simulation training for ETV would be a valuable addition to clinical training. Selection of ventriculostomy site, navigation within the ventricles, and performance of the ventriculostomy ranked as the most important steps to simulate. Technically inadequate ventriculostomy and inappropriate fenestration site selection were ranked as the most frequent/significant errors. A standard ETV module was thought to be most beneficial for resident training. To inform the development of a simulation-based training program for ETV, the authors have conducted a national needs assessment. The results provide valuable insight to inform key design elements necessary to construct an educationally relevant device and educational program.
Hossain, Belal; Islam, Mohammad Shahidul; Rahman, Atiqur; Marzan, Mahfuza; Rafiqullah, Iftekhar; Connor, Nicholas E; Hasanuzzaman, Mohammad; Islam, Maksuda; Hamer, Davidson H; Hibberd, Patricia L; Saha, Samir K
2016-05-01
Interpretation of blood culture isolates is challenging due to a lack of standard methodologies for identifying contaminants. This problem becomes more complex when the specimens are from sick young infants, as a wide range of bacteria can cause illness among this group. We used 43 key words to find articles published between 1970 and 2011 on blood culture isolates and possible contaminants in the PubMed database. Experts were also consulted to obtain other relevant articles. Selection of articles followed systematic methods considering opinions from more than 1 reviewer. After reviewing the titles of 3869 articles extracted from the database, we found 307 relevant to our objective. Based on the abstracts, 42 articles were selected for the literature review. In addition, we included 7 more articles based on cross-references and expert advice. The most common methods for differentiating blood culture isolates were multiple blood cultures from the same subject, antibiograms and molecular testing. Streptococcus pneumoniae, Hemophilus influenzae, Neisseria meningitidis and group A and B streptococcus were always considered as pathogens, whereas Bacillus sp., Diphtheroids, Propionibacterium and Micrococcus were commonly regarded as contaminants. Coagulase-negative staphylococci were the most frequent isolates and usually reported as contaminants unless the patient had a specific condition, such as long-term hospitalization or use of invasive devices (catheters). Inaccurate interpretation of blood culture may falsely guide treatment and also has long-term policy implications. The combination of clinical and microbiological knowledge, patient's clinical history and laboratory findings are essential for appropriate interpretation of blood culture.
Factors Associated with Needlestick Injuries in Health Care Occupations: A Systematic Review.
Motaarefi, Hossein; Mahmoudi, Hosein; Mohammadi, Eesa; Hasanpour-Dehkordi, Ali
2016-08-01
Needlestick and sharps injuries (NSIs), are among the main job-related injuries that health care workers experience. In fact, contraction of hepatitis B or hepatitis C from work-related NSIs is one of the most common occupational hazards among health care workers. The aim of this study was to determine the factors associated with NSIs in health care occupation. In this study, a systematic and purposive review with emphasis on the research question was run to retrieve, evaluate and consolidate the required information. The following four key words were used to search for the relevant articles published from January 1998 to May 2015: NSI health care workers, risk factor and factors associated, in Science direct, EBSCO Host, PubMed, ProQuest, SID and Cochrane Library. Several steps of evaluation were taken to select and analyse the full texts of relevant articles. According to the inclusion criteria, we finally selected 11 articles from the 18642 retrieved articles. The data of the analysed articles indicated that the highest incidence of NSIs was seen in nurses and that the associated factors were age, level of education, number of shifts per month and history of related training. The highest rate of NSIs was related to instrument preparation followed by injection and recapping of used needles. Findings show that health care workers suffer a high rate of needlestick injuries. It was seen that device, location, or action cannot be separately considered as responsible for all types of the NSIs. Rather, each of them has a contribution to the NSIs. Nevertheless, factors with higher frequency should be given a higher priority.
Jenks, Michelle; Craig, Joyce; Higgins, Joanne; Willits, Iain; Barata, Teresa; Wood, Hannah; Kimpton, Christine; Sims, Andrew
2014-12-01
Scoliosis-structural lateral curvature of the spine-affects around four children per 1,000. The MAGEC system comprises a magnetically distractible spinal rod implant and an external remote controller, which lengthens the rod; this system avoids repeated surgical lengthening. Rod implants brace the spine internally and are lengthened as the child grows, preventing worsening of scoliosis and delaying the need for spinal fusion. The Medical Technologies Advisory Committee at the National Institute for Health and Care Excellence (NICE) selected the MAGEC system for evaluation in a NICE medical technologies guidance. Six studies were identified by the sponsor (Ellipse Technologies Inc.) as being relevant to the decision problem. Meta-analysis was used to compare the clinical evidence results with those of one conventional growth rod study, and equal efficacy of the two devices was concluded. The key weakness was selection of a single comparator study. The External Assessment Centre (EAC) identified 16 conventional growth rod studies and undertook meta-analyses of relevant outcomes. Its critique highlighted limitations around study heterogeneity and variations in baseline characteristics and follow-up duration, precluding the ability to draw firm conclusions. The sponsor constructed a de novo costing model showing that MAGEC rods generated cost savings of £9,946 per patient after 6 years, compared with conventional rods. The EAC critiqued and updated the model structure and inputs, calculating robust cost savings of £12,077 per patient with MAGEC rods compared with conventional rods over 6 years. The year of valuation was 2012. NICE issued a positive recommendation as supported by the evidence (Medical Technologies Guidance 18).
Elyasigomari, V; Lee, D A; Screen, H R C; Shaheed, M H
2017-03-01
For each cancer type, only a few genes are informative. Due to the so-called 'curse of dimensionality' problem, the gene selection task remains a challenge. To overcome this problem, we propose a two-stage gene selection method called MRMR-COA-HS. In the first stage, the minimum redundancy and maximum relevance (MRMR) feature selection is used to select a subset of relevant genes. The selected genes are then fed into a wrapper setup that combines a new algorithm, COA-HS, using the support vector machine as a classifier. The method was applied to four microarray datasets, and the performance was assessed by the leave one out cross-validation method. Comparative performance assessment of the proposed method with other evolutionary algorithms suggested that the proposed algorithm significantly outperforms other methods in selecting a fewer number of genes while maintaining the highest classification accuracy. The functions of the selected genes were further investigated, and it was confirmed that the selected genes are biologically relevant to each cancer type. Copyright © 2017. Published by Elsevier Inc.
Diagnostic for two-mode variable valve activation device
Fedewa, Andrew M
2014-01-07
A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.
Optimized Energy Harvesting, Cluster-Head Selection and Channel Allocation for IoTs in Smart Cities
Aslam, Saleem; Hasan, Najam Ul; Jang, Ju Wook; Lee, Kyung-Geun
2016-01-01
This paper highlights three critical aspects of the internet of things (IoTs), namely (1) energy efficiency, (2) energy balancing and (3) quality of service (QoS) and presents three novel schemes for addressing these aspects. For energy efficiency, a novel radio frequency (RF) energy-harvesting scheme is presented in which each IoT device is associated with the best possible RF source in order to maximize the overall energy that the IoT devices harvest. For energy balancing, the IoT devices in close proximity are clustered together and then an IoT device with the highest residual energy is selected as a cluster head (CH) on a rotational basis. Once the CH is selected, it assigns channels to the IoT devices to report their data using a novel integer linear program (ILP)-based channel allocation scheme by satisfying their desired QoS. To evaluate the presented schemes, exhaustive simulations are carried out by varying different parameters, including the number of IoT devices, the number of harvesting sources, the distance between RF sources and IoT devices and the primary user (PU) activity of different channels. The simulation results demonstrate that our proposed schemes perform better than the existing ones. PMID:27918424
Optimized Energy Harvesting, Cluster-Head Selection and Channel Allocation for IoTs in Smart Cities.
Aslam, Saleem; Hasan, Najam Ul; Jang, Ju Wook; Lee, Kyung-Geun
2016-12-02
This paper highlights three critical aspects of the internet of things (IoTs), namely (1) energy efficiency, (2) energy balancing and (3) quality of service (QoS) and presents three novel schemes for addressing these aspects. For energy efficiency, a novel radio frequency (RF) energy-harvesting scheme is presented in which each IoT device is associated with the best possible RF source in order to maximize the overall energy that the IoT devices harvest. For energy balancing, the IoT devices in close proximity are clustered together and then an IoT device with the highest residual energy is selected as a cluster head (CH) on a rotational basis. Once the CH is selected, it assigns channels to the IoT devices to report their data using a novel integer linear program (ILP)-based channel allocation scheme by satisfying their desired QoS. To evaluate the presented schemes, exhaustive simulations are carried out by varying different parameters, including the number of IoT devices, the number of harvesting sources, the distance between RF sources and IoT devices and the primary user (PU) activity of different channels. The simulation results demonstrate that our proposed schemes perform better than the existing ones.
3D printed conformal microfluidics for isolation and profiling of biomarkers from whole organs.
Singh, Manjot; Tong, Yuxin; Webster, Kelly; Cesewski, Ellen; Haring, Alexander P; Laheri, Sahil; Carswell, Bill; O'Brien, Timothy J; Aardema, Charles H; Senger, Ryan S; Robertson, John L; Johnson, Blake N
2017-07-25
The ability to interface microfluidic devices with native complex biological architectures, such as whole organs, has the potential to shift the paradigm for the study and analysis of biological tissue. Here, we show 3D printing can be used to fabricate bio-inspired conformal microfluidic devices that directly interface with the surface of whole organs. Structured-light scanning techniques enabled the 3D topographical matching of microfluidic device geometry to porcine kidney anatomy. Our studies show molecular species are spontaneously transferred from the organ cortex to the conformal microfluidic device in the presence of fluid flow through the organ-conforming microchannel. Large animal studies using porcine kidneys (n = 32 organs) revealed the profile of molecular species in the organ-conforming microfluidic stream was dependent on the organ preservation conditions. Enzyme-linked immunosorbent assay (ELISA) studies revealed conformal microfluidic devices isolate clinically relevant metabolic and pathophysiological biomarkers from whole organs, including heat shock protein 70 (HSP-70) and kidney injury molecule-1 (KIM-1), which were detected in the microfluidic device as high as 409 and 12 pg mL -1 , respectively. Overall, these results show conformal microfluidic devices enable a novel minimally invasive 'microfluidic biopsy' technique for isolation and profiling of biomarkers from whole organs within a clinically relevant interval. This achievement could shift the paradigm for whole organ preservation and assessment, thereby helping to relieve the organ shortage crisis through increased availability and quality of donor organs. Ultimately, this work provides a major advance in microfluidics through the design and manufacturing of organ-conforming microfluidic devices and a novel technique for microfluidic-based analysis of whole organs.
Best, Catherine A.; Yim, Hyungwook; Sloutsky, Vladimir M.
2013-01-01
Selective attention plays an important role in category learning. However, immaturities of top-down attentional control during infancy coupled with successful category learning suggest that early category learning is achieved without attending selectively. Research presented here examines this possibility by focusing on category learning in infants (6–8 months old) and adults. Participants were trained on a novel visual category. Halfway through the experiment, unbeknownst to participants, the to-be-learned category switched to another category, where previously relevant features became irrelevant and previously irrelevant features became relevant. If participants attend selectively to the relevant features of the first category, they should incur a cost of selective attention immediately after the unknown category switch. Results revealed that adults demonstrated a cost, as evidenced by a decrease in accuracy and response time on test trials as well as a decrease in visual attention to newly relevant features. In contrast, infants did not demonstrate a similar cost of selective attention as adults despite evidence of learning both to-be-learned categories. Findings are discussed as supporting multiple systems of category learning and as suggesting that learning mechanisms engaged by adults may be different from those engaged by infants. PMID:23773914
Khan, Adil G; Poort, Jasper; Chadwick, Angus; Blot, Antonin; Sahani, Maneesh; Mrsic-Flogel, Thomas D; Hofer, Sonja B
2018-06-01
How learning enhances neural representations for behaviorally relevant stimuli via activity changes of cortical cell types remains unclear. We simultaneously imaged responses of pyramidal cells (PYR) along with parvalbumin (PV), somatostatin (SOM), and vasoactive intestinal peptide (VIP) inhibitory interneurons in primary visual cortex while mice learned to discriminate visual patterns. Learning increased selectivity for task-relevant stimuli of PYR, PV and SOM subsets but not VIP cells. Strikingly, PV neurons became as selective as PYR cells, and their functional interactions reorganized, leading to the emergence of stimulus-selective PYR-PV ensembles. Conversely, SOM activity became strongly decorrelated from the network, and PYR-SOM coupling before learning predicted selectivity increases in individual PYR cells. Thus, learning differentially shapes the activity and interactions of multiple cell classes: while SOM inhibition may gate selectivity changes, PV interneurons become recruited into stimulus-specific ensembles and provide more selective inhibition as the network becomes better at discriminating behaviorally relevant stimuli.
2016-03-07
and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the...broad spectrum of toxic industrial compounds rapidly (within an hour) at concentrations relevant to human health , that the device be field-portable...laboratory setting and was able to detect potential water contaminants at concentrations that are relevant to human health . The portability and
1975-06-01
MECHANISM : ALUMINOSILICATE ORGANIC INTERACTION IN SALINE WATERS, A.C.S. Tom M 21 (1969-1970) to be published in Advances in Chemistry Series. 5...recovery mechanisms . Detailed information on various devices is given in Sittig3 and by EPA. (1) WEIR DEVICES Weir devices depend on gravity to... mechanical eguipments. The selection depends on the depth of oil penetration: 1. For oil penetration of up to 1 inch, combined use of road graders and
Brandhorst, Jr., Henry W.; Chen, Zheng
2000-01-01
Efficient thermophotovoltaic conversion can be performed using photovoltaic devices with a band gap in the 0.75-1.4 electron volt range, and selective infrared emitters chosen from among the rare earth oxides which are thermally stimulated to emit infrared radiation whose energy very largely corresponds to the aforementioned band gap. It is possible to use thermovoltaic devices operating at relatively high temperatures, up to about 300.degree. C., without seriously impairing the efficiency of energy conversion.
Thermal management and design for optical refrigeration
NASA Astrophysics Data System (ADS)
Symonds, G.; Farfan, B. G.; Ghasemkhani, M. R.; Albrecht, A. R.; Sheik-Bahae, M.; Epstein, R. I.
2016-03-01
We present our recent work in developing a robust and versatile optical refrigerator. This work focuses on minimizing parasitic energy losses through efficient design and material optimization. The cooler's thermal linkage system and housing are studied using thermal analysis software to minimize thermal gradients through the device. Due to the extreme temperature differences within the device, material selection and characterization are key to constructing an efficient device. We describe the design constraints and material selections necessary for thermally efficient and durable optical refrigeration.
Utilizing Adaptive Devices with Severely Handicapped Students.
ERIC Educational Resources Information Center
Nisbet, Jan; And Others
The task force report examines the use of adaptive devices by severely handicapped students. Interviews with teachers and therapists produced information on the selection, development, and use of the devices. Four practices that positively influenced the devices' use were identified: (1) design and construction following establishment of…
Device and Method for Gathering Ensemble Data Sets
NASA Technical Reports Server (NTRS)
Racette, Paul E. (Inventor)
2014-01-01
An ensemble detector uses calibrated noise references to produce ensemble sets of data from which properties of non-stationary processes may be extracted. The ensemble detector comprising: a receiver; a switching device coupled to the receiver, the switching device configured to selectively connect each of a plurality of reference noise signals to the receiver; and a gain modulation circuit coupled to the receiver and configured to vary a gain of the receiver based on a forcing signal; whereby the switching device selectively connects each of the plurality of reference noise signals to the receiver to produce an output signal derived from the plurality of reference noise signals and the forcing signal.
Doty, Diane
2015-12-01
Mechanical circulatory support (MCS) devices offer advanced heart failure patients a potential long-term solution. MCS devices implantation is increasing related to the increased volume of heart failure patients, the shortfall of suitable donors, and the advanced technology and smaller size of the devices. To ensure a successful outcome, some key elements must be taken into consideration and managed: patient selection, preoperative preparation, intraoperative care, postoperative care, and posthospital education. The ultimate success of an MCS implantation relies on a multidisciplinary approach and excellent patient/caregiver education in each phase of hospitalization. Copyright © 2015 Elsevier Inc. All rights reserved.
Cowger, Jennifer; Romano, Matthew A; Stulak, John; Pagani, Francis D; Aaronson, Keith D
2011-03-01
This review summarizes management strategies to reduce morbidity and mortality in heart failure patients supported chronically with implantable left ventricular assist devices (LVADs). As the population of patients supported with long-term LVADs has grown, patient selection, operative technique, and patient management strategies have been refined, leading to improved outcomes. This review summarizes recent findings on LVAD candidate selection, and discusses outpatient strategies to optimize device performance and heart failure management. It also reviews important device complications that warrant close outpatient monitoring. Managing patients on chronic LVAD support requires regular patient follow-up, multidisciplinary care teams, and frequent laboratory and echocardiographic surveillance to ensure optimal outcomes.
What is the Optimal Strategy for Adaptive Servo-Ventilation Therapy?
Imamura, Teruhiko; Kinugawa, Koichiro
2018-05-23
Clinical advantages in the adaptive servo-ventilation (ASV) therapy have been reported in selected heart failure patients with/without sleep-disorder breathing, whereas multicenter randomized control trials could not demonstrate such advantages. Considering this discrepancy, optimal patient selection and device setting may be a key for the successful ASV therapy. Hemodynamic and echocardiographic parameters indicating pulmonary congestion such as elevated pulmonary capillary wedge pressure were reported as predictors of good response to ASV therapy. Recently, parameters indicating right ventricular dysfunction also have been reported as good predictors. Optimal device setting with appropriate pressure setting during appropriate time may also be a key. Large-scale prospective trial with optimal patient selection and optimal device setting is warranted.
Nanowire structures and electrical devices
Bezryadin, Alexey; Remeika, Mikas
2010-07-06
The present invention provides structures and devices comprising conductive segments and conductance constricting segments of a nanowire, such as metallic, superconducting or semiconducting nanowire. The present invention provides structures and devices comprising conductive nanowire segments and conductance constricting nanowire segments having accurately selected phases including crystalline and amorphous states, compositions, morphologies and physical dimensions, including selected cross sectional dimensions, shapes and lengths along the length of a nanowire. Further, the present invention provides methods of processing nanowires capable of patterning a nanowire to form a plurality of conductance constricting segments having selected positions along the length of a nanowire, including conductance constricting segments having reduced cross sectional dimensions and conductance constricting segments comprising one or more insulating materials such as metal oxides.
Selective excitation of window and buffer layers in chalcopyrite devices and modules
Glynn, Stephen; Repins, Ingrid L.; Burst, James M.; ...
2018-02-02
Window and buffer layers in chalcopyrite devices are well known to affect junctions, conduction, and photo-absorption properties of the device. Some of these layers, particularly 'buffers,' which are deposited directly on top of the absorber, exhibit metastable effects upon exposure to light. Thus, to understand device performance and/or metastability, it is sometimes desirable to selectively excite different layers in the device stack. Absorption characteristics of various window and buffer layers used in chalcopyrite devices are measured. These characteristics are compared with emission spectra of common and available light sources that might be used to optically excite such layers. Effects ofmore » the window and buffer absorption on device quantum efficiency and metastability are discussed. For the case of bath-deposited Zn(O,S) buffers, we conclude that this layer is not optically excited in research devices or modules. Furthermore, this provides a complimentary mechanism to the chemical differences that may cause long time constants (compared to devices with CdS buffers) associated with reaching a stable 'light-soaked' state.« less
Selective excitation of window and buffer layers in chalcopyrite devices and modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glynn, Stephen; Repins, Ingrid L.; Burst, James M.
Window and buffer layers in chalcopyrite devices are well known to affect junctions, conduction, and photo-absorption properties of the device. Some of these layers, particularly 'buffers,' which are deposited directly on top of the absorber, exhibit metastable effects upon exposure to light. Thus, to understand device performance and/or metastability, it is sometimes desirable to selectively excite different layers in the device stack. Absorption characteristics of various window and buffer layers used in chalcopyrite devices are measured. These characteristics are compared with emission spectra of common and available light sources that might be used to optically excite such layers. Effects ofmore » the window and buffer absorption on device quantum efficiency and metastability are discussed. For the case of bath-deposited Zn(O,S) buffers, we conclude that this layer is not optically excited in research devices or modules. Furthermore, this provides a complimentary mechanism to the chemical differences that may cause long time constants (compared to devices with CdS buffers) associated with reaching a stable 'light-soaked' state.« less
Role of orientation reference selection in motion sickness
NASA Technical Reports Server (NTRS)
Peterka, Robert J.; Black, F. Owen
1992-01-01
The overall objective of this proposal is to understand the relationship between human orientation control and motion sickness susceptibility. Three areas related to orientation control will be investigated. These three areas are (1) reflexes associated with the control of eye movements and posture, (2) the perception of body rotation and position with respect to gravity, and (3) the strategies used to resolve sensory conflict situations which arise when different sensory systems provide orientation cues which are not consistent with one another or with previous experience. Of particular interest is the possibility that a subject may be able to ignore an inaccurate sensory modality in favor of one or more other sensory modalities which do provide accurate orientation reference information. We refer to this process as sensory selection. This proposal will attempt to quantify subjects' sensory selection abilities and determine if this ability confers some immunity to the development of motion sickness symptoms. Measurements of reflexes, motion perception, sensory selection abilities, and motion sickness susceptibility will concentrate on pitch and roll motions since these seem most relevant to the space motion sickness problem. Vestibulo-ocular (VOR) and oculomotor reflexes will be measured using a unique two-axis rotation device developed in our laboratory over the last seven years. Posture control reflexes will be measured using a movable posture platform capable of independently altering proprioceptive and visual orientation cues. Motion perception will be quantified using closed loop feedback technique developed by Zacharias and Young (Exp Brain Res, 1981). This technique requires a subject to null out motions induced by the experimenter while being exposed to various confounding sensory orientation cues. A subject's sensory selection abilities will be measured by the magnitude and timing of his reactions to changes in sensory environments. Motion sickness susceptibility will be measured by the time required to induce characteristic changes in the pattern of electrogastrogram recordings while exposed to various sensory environments during posture and motion perception tests. The results of this work are relevant to NASA's interest in understanding the etiology of space motion sickness. If any of the reflex, perceptual, or sensory selection abilities of subjects are found to correlate with motion sickness susceptibility, this work may be an important step in suggesting a method of predicting motion sickness susceptibility. If sensory selection can provide a means to avoid sensory conflict, then further work may lead to training programs which could enhance a subject's sensory selection ability and therefore minimize motion sickness susceptibility.
Automatic Detection of Seizures with Applications
NASA Technical Reports Server (NTRS)
Olsen, Dale E.; Harris, John C.; Cutchis, Protagoras N.; Cristion, John A.; Lesser, Ronald P.; Webber, W. Robert S.
1993-01-01
There are an estimated two million people with epilepsy in the United States. Many of these people do not respond to anti-epileptic drug therapy. Two devices can be developed to assist in the treatment of epilepsy. The first is a microcomputer-based system designed to process massive amounts of electroencephalogram (EEG) data collected during long-term monitoring of patients for the purpose of diagnosing seizures, assessing the effectiveness of medical therapy, or selecting patients for epilepsy surgery. Such a device would select and display important EEG events. Currently many such events are missed. A second device could be implanted and would detect seizures and initiate therapy. Both of these devices require a reliable seizure detection algorithm. A new algorithm is described. It is believed to represent an improvement over existing seizure detection algorithms because better signal features were selected and better standardization methods were used.
Integrated Microfluidic System for Size-Based Selection and Trapping of Giant Vesicles.
Kazayama, Yuki; Teshima, Tetsuhiko; Osaki, Toshihisa; Takeuchi, Shoji; Toyota, Taro
2016-01-19
Vesicles composed of phospholipids (liposomes) have attracted interest as artificial cell models and have been widely studied to explore lipid-lipid and lipid-protein interactions. However, the size dispersity of liposomes prepared by conventional methods was a major problem that inhibited their use in high-throughput analyses based on monodisperse liposomes. In this study, we developed an integrative microfluidic device that enables both the size-based selection and trapping of liposomes. This device consists of hydrodynamic selection and trapping channels in series, which made it possible to successfully produce an array of more than 60 monodisperse liposomes from a polydisperse liposome suspension with a narrow size distribution (the coefficient of variation was less than 12%). We successfully observed a size-dependent response of the liposomes to sequential osmotic stimuli, which had not clarified so far, by using this device. Our device will be a powerful tool to facilitate the statistical analysis of liposome dynamics.
Spence, Hollie; Baker, Kevin; Wharton-Smith, Alexandra; Mucunguzi, Akasiima; Matata, Lena; Habte, Tedila; Nanyumba, Diana; Sebsibe, Anteneh; Thany, Thol; Källander, Karin
2017-01-01
Pneumonia heavily contributes to global under-five mortality. Many countries use community case management to detect and treat childhood pneumonia. Community health workers (CHWs) have limited tools to help them assess signs of pneumonia. New respiratory rate (RR) counting devices and pulse oximeters are being considered for this purpose. To explore perspectives of CHWs and national stakeholders regarding the potential usability and scalability of seven devices to aid community assessment of pneumonia signs. Pile sorting was conducted to rate the usability and scalability of 7 different RR counting aids and pulse oximeters amongst 16 groups of participants. Following each pile-sorting session, a focus group discussion (FGD) explored participants' sorting rationale. Purposive sampling was used to select CHWs and national stakeholders with experience in childhood pneumonia and integrated community case management (iCCM) in Cambodia, Ethiopia, Uganda and South Sudan. Pile-sorting data were aggregated for countries and participant groups. FGDs were audio recorded and transcribed verbatim. Translated FGDs transcripts were coded in NVivo 10 and analysed using thematic content analysis. Comparative analysis was performed between countries and groups to identify thematic patterns. CHWs and national stakeholders across the four countries perceived the acute respiratory infection (ARI) timer and fingertip pulse oximeter as highly scalable and easy for CHWs to use. National stakeholders were less receptive to new technologies. CHWs placed greater priority on device acceptability to caregivers and children. Both groups felt that heavy reliance on electricity reduced potential scalability and usability in rural areas. Device simplicity, affordability and sustainability were universally valued. CHWs and national stakeholders prioritise different device characteristics according to their specific focus of work. The views of all relevant stakeholders, including health workers, policy makers, children and parents, should be considered in future policy decisions, research and development regarding suitable pneumonia diagnostic aids for community use.
Rambach, Richard W; Biswas, Preetika; Yadav, Ashutosh; Garstecki, Piotr; Franke, Thomas
2018-02-12
The selective manipulation and incubation of individual picoliter drops in high-throughput droplet based microfluidic devices still remains challenging. We used a surface acoustic wave (SAW) to induce a bubble in a 3D designed multi-trap polydimethylsiloxane (PDMS) device to manipulate multiple droplets and demonstrate the selection, incubation and on-demand release of aqueous droplets from a continuous oil flow. By controlling the position of the acoustic actuation, individual droplets are addressed and selectively released from a droplet stream of 460 drops per s. A complete trapping and releasing cycle can be as short as 70 ms and has no upper limit for incubation time. We characterize the fluidic function of the hybrid device in terms of electric power, pulse duration and acoustic path.
The use of Food and Drug Administration 510(k) notifications in patent litigation.
Tolomeo, Deborah E
2004-01-01
The U.S. Food and Drug Administration (FDA) 510(k) approval process provides medical device companies with the ability to market a device after the company establishes that the device to the marketed is "substantially equivalent" to one or more predicate devices. Companies that submit 510(k) notifications should be aware, however, that a 510(k) notification is a public document that may later reappear as evidence in patent litigation. Courts have considered 510(k) notifications to be relevant evidence in determining direct and contributory infringement, patent invalidity, and patent unenforceability due to inequitable conduct before the U.S. Patent and Trademark Office (USPTO). In one case, the court held that a substantial equivalence determination by FDA constituted evidence that can be "construed as an admission of infringement." The court also has relied on a 510(k) notification to support a finding of personal liability for a corporate officer who signed the 510(k) notification to be evidence of willful and deliberate conduct, and have awarded treble damages and reasonable attorney's fees to the prevailing party. The potential for increased risk in patent litigation is important for practitioners in the medical device industry, because more than seventy-five percent of medical devices are approved for marketing through the 510(k) process. This article reviews a number of patent cases in which a court has admitted a 510(k) notification as relevant evidence, and proposes general strategies for avoiding these situations.
A numerically efficient damping model for acoustic resonances in microfluidic cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hahn, P., E-mail: hahnp@ethz.ch; Dual, J.
Bulk acoustic wave devices are typically operated in a resonant state to achieve enhanced acoustic amplitudes and high acoustofluidic forces for the manipulation of microparticles. Among other loss mechanisms related to the structural parts of acoustofluidic devices, damping in the fluidic cavity is a crucial factor that limits the attainable acoustic amplitudes. In the analytical part of this study, we quantify all relevant loss mechanisms related to the fluid inside acoustofluidic micro-devices. Subsequently, a numerical analysis of the time-harmonic visco-acoustic and thermo-visco-acoustic equations is carried out to verify the analytical results for 2D and 3D examples. The damping results aremore » fitted into the framework of classical linear acoustics to set up a numerically efficient device model. For this purpose, all damping effects are combined into an acoustofluidic loss factor. Since some components of the acoustofluidic loss factor depend on the acoustic mode shape in the fluid cavity, we propose a two-step simulation procedure. In the first step, the loss factors are deduced from the simulated mode shape. Subsequently, a second simulation is invoked, taking all losses into account. Owing to its computational efficiency, the presented numerical device model is of great relevance for the simulation of acoustofluidic particle manipulation by means of acoustic radiation forces or acoustic streaming. For the first time, accurate 3D simulations of realistic micro-devices for the quantitative prediction of pressure amplitudes and the related acoustofluidic forces become feasible.« less
Clinical Research Informatics: Supporting the Research Study Lifecycle.
Johnson, S B
2017-08-01
Objectives: The primary goal of this review is to summarize significant developments in the field of Clinical Research Informatics (CRI) over the years 2015-2016. The secondary goal is to contribute to a deeper understanding of CRI as a field, through the development of a strategy for searching and classifying CRI publications. Methods: A search strategy was developed to query the PubMed database, using medical subject headings to both select and exclude articles, and filtering publications by date and other characteristics. A manual review classified publications using stages in the "research study lifecycle", with key stages that include study definition, participant enrollment, data management, data analysis, and results dissemination. Results: The search strategy generated 510 publications. The manual classification identified 125 publications as relevant to CRI, which were classified into seven different stages of the research lifecycle, and one additional class that pertained to multiple stages, referring to general infrastructure or standards. Important cross-cutting themes included new applications of electronic media (Internet, social media, mobile devices), standardization of data and procedures, and increased automation through the use of data mining and big data methods. Conclusions: The review revealed increased interest and support for CRI in large-scale projects across institutions, regionally, nationally, and internationally. A search strategy based on medical subject headings can find many relevant papers, but a large number of non-relevant papers need to be detected using text words which pertain to closely related fields such as computational statistics and clinical informatics. The research lifecycle was useful as a classification scheme by highlighting the relevance to the users of clinical research informatics solutions. Georg Thieme Verlag KG Stuttgart.
7 CFR 3430.33 - Selection of reviewers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... selected based upon training and experience in relevant scientific, extension, or education fields taking into account the following factors: (1) Level of relevant formal scientific, technical education, and... research, education, or extension activities. (2) Need to include as reviewers experts from various areas...
7 CFR 3430.33 - Selection of reviewers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... selected based upon training and experience in relevant scientific, extension, or education fields taking into account the following factors: (1) Level of relevant formal scientific, technical education, and... research, education, or extension activities. (2) Need to include as reviewers experts from various areas...
7 CFR 3430.33 - Selection of reviewers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... selected based upon training and experience in relevant scientific, extension, or education fields taking into account the following factors: (1) Level of relevant formal scientific, technical education, and... research, education, or extension activities. (2) Need to include as reviewers experts from various areas...
Effects of selective attention on continuous opinions and discrete decisions
NASA Astrophysics Data System (ADS)
Si, Xia-Meng; Liu, Yun; Xiong, Fei; Zhang, Yan-Chao; Ding, Fei; Cheng, Hui
2010-09-01
Selective attention describes that individuals have a preference on information according to their involving motivation. Based on achievements of social psychology, we propose an opinion interacting model to improve the modeling of individuals’ interacting behaviors. There are two parameters governing the probability of agents interacting with opponents, i.e. individual relevance and time-openness. It is found that, large individual relevance and large time-openness advance the appearance of large clusters, but large individual relevance and small time-openness favor the lessening of extremism. We also put this new model into application to work out some factor leading to a successful product. Numerical simulations show that selective attention, especially individual relevance, cannot be ignored by launcher firms and information spreaders so as to attain the most successful promotion.
Attention improves encoding of task-relevant features in the human visual cortex
Jehee, Janneke F.M.; Brady, Devin K.; Tong, Frank
2011-01-01
When spatial attention is directed towards a particular stimulus, increased activity is commonly observed in corresponding locations of the visual cortex. Does this attentional increase in activity indicate improved processing of all features contained within the attended stimulus, or might spatial attention selectively enhance the features relevant to the observer’s task? We used fMRI decoding methods to measure the strength of orientation-selective activity patterns in the human visual cortex while subjects performed either an orientation or contrast discrimination task, involving one of two laterally presented gratings. Greater overall BOLD activation with spatial attention was observed in areas V1-V4 for both tasks. However, multivariate pattern analysis revealed that orientation-selective responses were enhanced by attention only when orientation was the task-relevant feature, and not when the grating’s contrast had to be attended. In a second experiment, observers discriminated the orientation or color of a specific lateral grating. Here, orientation-selective responses were enhanced in both tasks but color-selective responses were enhanced only when color was task-relevant. In both experiments, task-specific enhancement of feature-selective activity was not confined to the attended stimulus location, but instead spread to other locations in the visual field, suggesting the concurrent involvement of a global feature-based attentional mechanism. These results suggest that attention can be remarkably selective in its ability to enhance particular task-relevant features, and further reveal that increases in overall BOLD amplitude are not necessarily accompanied by improved processing of stimulus information. PMID:21632942
Attention improves encoding of task-relevant features in the human visual cortex.
Jehee, Janneke F M; Brady, Devin K; Tong, Frank
2011-06-01
When spatial attention is directed toward a particular stimulus, increased activity is commonly observed in corresponding locations of the visual cortex. Does this attentional increase in activity indicate improved processing of all features contained within the attended stimulus, or might spatial attention selectively enhance the features relevant to the observer's task? We used fMRI decoding methods to measure the strength of orientation-selective activity patterns in the human visual cortex while subjects performed either an orientation or contrast discrimination task, involving one of two laterally presented gratings. Greater overall BOLD activation with spatial attention was observed in visual cortical areas V1-V4 for both tasks. However, multivariate pattern analysis revealed that orientation-selective responses were enhanced by attention only when orientation was the task-relevant feature and not when the contrast of the grating had to be attended. In a second experiment, observers discriminated the orientation or color of a specific lateral grating. Here, orientation-selective responses were enhanced in both tasks, but color-selective responses were enhanced only when color was task relevant. In both experiments, task-specific enhancement of feature-selective activity was not confined to the attended stimulus location but instead spread to other locations in the visual field, suggesting the concurrent involvement of a global feature-based attentional mechanism. These results suggest that attention can be remarkably selective in its ability to enhance particular task-relevant features and further reveal that increases in overall BOLD amplitude are not necessarily accompanied by improved processing of stimulus information.
2016-12-19
32λ (angular divergence of 1.8°) which is quasi -monochromatic with a full width at half maximum of 70 nm. These experimental results show good...devices; plasmonic TO structures; and tapered waveguide analog TO devices. Of particular relevance is the development of quasi - conformal (QC...the development of quasi -conformal (QC) optimization techniques that lead to more realizable TO designs, appropriate for the shorter wavelengths of
Measurements relevant to the performance of infrared opto-electronic devices in fog
NASA Astrophysics Data System (ADS)
Clay, M. R.; Lenham, A. P.
1981-04-01
The transmissivity of the atmosphere in the visible and infrared was measured in a number of fogs. The data is summarized in the form of tables and diagrams that indicate the gain in range that may be achievable in the various infrared windows. In some fogs there does not appear to be any significant advantage in using infrared devices.
Wireless Integrated Biosensors for Point-of-Care Diagnostic Applications
Ghafar-Zadeh, Ebrahim
2015-01-01
Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer’s. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field. PMID:25648709
NASA Astrophysics Data System (ADS)
Gao, Li; Zhang, Yihui; Malyarchuk, Viktor; Jia, Lin; Jang, Kyung-In; Chad Webb, R.; Fu, Haoran; Shi, Yan; Zhou, Guoyan; Shi, Luke; Shah, Deesha; Huang, Xian; Xu, Baoxing; Yu, Cunjiang; Huang, Yonggang; Rogers, John A.
2014-09-01
Characterization of temperature and thermal transport properties of the skin can yield important information of relevance to both clinical medicine and basic research in skin physiology. Here we introduce an ultrathin, compliant skin-like, or ‘epidermal’, photonic device that combines colorimetric temperature indicators with wireless stretchable electronics for thermal measurements when softly laminated on the skin surface. The sensors exploit thermochromic liquid crystals patterned into large-scale, pixelated arrays on thin elastomeric substrates; the electronics provide means for controlled, local heating by radio frequency signals. Algorithms for extracting patterns of colour recorded from these devices with a digital camera and computational tools for relating the results to underlying thermal processes near the skin surface lend quantitative value to the resulting data. Application examples include non-invasive spatial mapping of skin temperature with milli-Kelvin precision (±50 mK) and sub-millimetre spatial resolution. Demonstrations in reactive hyperaemia assessments of blood flow and hydration analysis establish relevance to cardiovascular health and skin care, respectively.
Gao, Li; Zhang, Yihui; Malyarchuk, Viktor; Jia, Lin; Jang, Kyung-In; Webb, R Chad; Fu, Haoran; Shi, Yan; Zhou, Guoyan; Shi, Luke; Shah, Deesha; Huang, Xian; Xu, Baoxing; Yu, Cunjiang; Huang, Yonggang; Rogers, John A
2014-09-19
Characterization of temperature and thermal transport properties of the skin can yield important information of relevance to both clinical medicine and basic research in skin physiology. Here we introduce an ultrathin, compliant skin-like, or 'epidermal', photonic device that combines colorimetric temperature indicators with wireless stretchable electronics for thermal measurements when softly laminated on the skin surface. The sensors exploit thermochromic liquid crystals patterned into large-scale, pixelated arrays on thin elastomeric substrates; the electronics provide means for controlled, local heating by radio frequency signals. Algorithms for extracting patterns of colour recorded from these devices with a digital camera and computational tools for relating the results to underlying thermal processes near the skin surface lend quantitative value to the resulting data. Application examples include non-invasive spatial mapping of skin temperature with milli-Kelvin precision (±50 mK) and sub-millimetre spatial resolution. Demonstrations in reactive hyperaemia assessments of blood flow and hydration analysis establish relevance to cardiovascular health and skin care, respectively.
Delivery of inhaled drugs for infants and small children: a commentary on present and future needs.
Fink, James B
2012-11-01
Although the manufacture of inhaled medications is a multibillion dollar industry, virtually no pharmaceutical drug/device combination has been approved for inhalation across the range of pediatric patient ages and sizes. The clinician who treats neonates, infants, or toddlers is often faced with the dilemma of prescribing inhaled medications that may be disease appropriate but have not been approved for use in patients in these age categories. Their use is thus technically "off label," with limited empirical data to guide both dose and device selection. This dilemma requires the prescribing physician to go beyond the limitations of the product label, often without benefit of appropriately designed clinical trials, in an attempt to select safe and effective doses for use with these smallest of patients. The vast majority of drugs approved for inhalation were studied by using aerosol devices designed for older children and adults using a mouthpiece interface, which may not be practical for use in infants and patients aged <4 years. The selection of the most age-appropriate device and interface is critical for the effective administration of the prescribed therapy. In the absence of industry-sponsored clinical trials in neonates, infants, and toddlers, in vitro and in vivo strategies may help guide age-appropriate dosing, device, and interface selection to better inform clinical practice. In this commentary, the challenges in developing and prescribing effective formulations for aerosol delivery across the range of pediatric ages and sizes are explored, with guidance for device and interface selection. Recommendations for future collaborative sharing of in vitro models and age-specific breathing patterns between academic and industry researchers could help regulators and clinicians better understand the impact age and size have on pulmonary drug delivery. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.
Francis, Jill J; Stockton, Charlotte; Eccles, Martin P; Johnston, Marie; Cuthbertson, Brian H; Grimshaw, Jeremy M; Hyde, Chris; Tinmouth, Alan; Stanworth, Simon J
2009-11-01
Many theories of behaviour are potentially relevant to predictive and intervention studies but most studies investigate a narrow range of theories. Michie et al. (2005) agreed 12 'theoretical domains' from 33 theories that explain behaviour change. They developed a 'Theoretical Domains Interview' (TDI) for identifying relevant domains for specific clinical behaviours, but the framework has not been used for selecting theories for predictive studies. It was used here to investigate clinicians' transfusion behaviour in intensive care units (ICU). Evidence suggests that red blood cells transfusion could be reduced for some patients without reducing quality of care. (1) To identify the domains relevant to transfusion practice in ICUs and neonatal intensive care units (NICUs), using the TDI. (2) To use the identified domains to select appropriate theories for a study predicting transfusion behaviour. An adapted TDI about managing a patient with borderline haemoglobin by watching and waiting instead of transfusing red blood cells was used to conduct semi-structured, one-to-one interviews with 18 intensive care consultants and neonatologists across the UK. Relevant theoretical domains were: knowledge, beliefs about capabilities, beliefs about consequences, social influences, behavioural regulation. Further analysis at the construct level resulted in selection of seven theoretical approaches relevant to this context: Knowledge-Attitude-Behaviour Model, Theory of Planned Behaviour, Social Cognitive Theory, Operant Learning Theory, Control Theory, Normative Model of Work Team Effectiveness and Action Planning Approaches. This study illustrated, the use of the TDI to identify relevant domains in a complex area of inpatient care. This approach is potentially valuable for selecting theories relevant to predictive studies and resulted in greater breadth of potential explanations than would be achieved if a single theoretical model had been adopted.
Elliptically polarizing adjustable phase insertion device
Carr, Roger
1995-01-01
An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets.
Laser velocimeter for near-surface measurements
NASA Technical Reports Server (NTRS)
Johnson, Dennis A. (Inventor)
1992-01-01
The present invention relates to a laser Doppler velocimeter for near-wall measurements which includes at least one beam-turning device. The beam-turning device receives laser light, reflects and redirects the light at various angles in order to obtain measurements for all three velocity components at grazing incident angles. The beam-turning device includes a mirror or prism at one end which reflects the received light in a particular direction. A collector lens receives the particle scattered light from which the relevant velocity components are determined. The beam-turning device can also be a miniature fiber optic head which outputs laser light and can be turned in any direction.
Optical methods for wireless implantable sensing platforms
NASA Astrophysics Data System (ADS)
Mujeeb-U-Rahman, Muhammad; Chang, Chieh-Feng; Scherer, Axel
2013-09-01
Ultra small scale implants have gained lots of importance for both acute and chronic applications. Optical techniques hold the key to miniaturizing these devices to long sought sub-mm scale. This will lead towards long term use of these devices for medically relevant applications. It can also allow using multiple of these devices at the same time and forming a true body area network of sensors. In this paper, we present optical power transfer to such devices and the techniques to harness this power for different applications, for example high voltage or high current applications. We also present methods for wireless data transfer from such implants.
Upconverting device for enhanced recogntion of certain wavelengths of light
Kross, Brian; McKIsson, John E; McKisson, John; Weisenberger, Andrew; Xi, Wenze; Zorn, Carl
2013-05-21
An upconverting device for enhanced recognition of selected wavelengths is provided. The device comprises a transparent light transmitter in combination with a plurality of upconverting nanoparticles. The device may a lens in eyewear or alternatively a transparent panel such as a window in an instrument or machine. In use the upconverting device is positioned between a light source and the eye(s) of the user of the upconverting device.
Multilayer Microfluidic Devices Created From A Single Photomask
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Ryan T.; Sheen, Allison M.; Jambovane, Sachin R.
2013-08-28
The time and expense associated with high quality photomask production can discourage the creation of multilayer microfluidic devices, as each layer currently requires a separate photomask. Here we describe an approach in which multilayer microfabricated devices can be created from a single photomask. The separate layers and their corresponding alignment marks are arranged in separate halves of the mask for two layer devices or quadrants for four layer devices. Selective exposure of the photomask features and rotation of the device substrate between exposures result in multiple copies of the devices on each wafer. Subsequent layers are aligned to patterned featuresmore » on the substrate with the same alignment accuracy as when multiple photomasks are used. We demonstrate this approach for fabricating devices employing multilayer soft lithography (MSL) for pneumatic valving. MSL devices containing as many as 5 layers (4 aligned fluidic layers plus a manually aligned control layer) were successfully created using this approach. Device design is also modularized, enabling the presence or absence of features as well as channel heights to be selected independently from one another. The use of a single photomask to create multilayer devices results in a dramatic savings of time and/or money required to advance from device design to completed prototype.« less
Allemand, Pierre M.; Grimes, Randall F.; Ingle, Andrew R.; Cronin, John P.; Kennedy, Steve R.; Agrawal, Anoop; Boulton, Jonathan M.
2001-01-01
An electrochromic device is disclosed having a selective ion transport layer which separates an electrochemically active material from an electrolyte containing a redox active material. The devices are particularly useful as large area architectural and automotive glazings due to there reduced back reaction.
Considerations in insulin delivery device selection.
Valentine, Virginia; Kruger, Davida F
2010-06-01
Recent guidelines from the American Diabetes Association and the European Association for the Study of Diabetes promote the use of insulin sooner rather than later in patients with type 2 diabetes to achieve goal range glucose control (< 7%) but remain silent on a recommendation for delivery system. Even though there is widespread consensus among experts and payers that people with type 2 diabetes should use insulin earlier to achieve tight control, it still remains an elusive goal. Benefits of pen-type delivery devices include accurate dosing, faster and easier setting of dose and injection times, and increased patient acceptance and adherence. Before healthcare professionals can recommend a delivery device, it is critical they understand not only the medication in the device but also the various features and benefits to the different devices available and how those impact the patient. We will present considerations to assist in making appropriate device selection, to optimize patient success.
MacDonald, Marjorie; O'Leary, Renee; Stockwell, Tim; Reist, Dan
2016-05-21
Under the shadow of the tobacco epidemic, the sale and use of e-cigarettes and other vapour devices is increasing dramatically. A contentious debate has risen within public health over the harms and benefits of these devices. Clearing the Air seeks to clarify the issues with a systematic review that informs the pressing regulatory and public health decisions to be made regarding these new products. Using an integrated knowledge translation approach, public health researchers and knowledge users will work collaboratively throughout the project. Our research questions are the following: (1) What are the health risks and benefits of vapour devices, and how do these compare to cigarettes? (2) What is the harm reduction potential of vapour devices for individuals, the environment, and society? (3) Does youth vapour device experimentation lead to cigarette use? (4) Can vapour devices be effective aids for tobacco cessation? and (5) What is the potential toxicity of second-hand vapour? We are using meta-narrative review to synthesize studies from diverse research traditions because of its capacity to address contestations around a topic. The project has six phases. In the planning phase, we finalized the research questions. In the search phase, we are locating academic publications and grey literature aided by a research librarian. The mapping phase involves categorizing these papers into research traditions to understand different perspectives on the evidence for each research question. In the appraisal phase, we will select and evaluate the relevant papers. Finally, in the synthesis phase, using analytic techniques unique to meta-narrative methodology, we will compare and contrast the evidence from different research traditions to answer our research questions, identifying overarching meta-narratives. In the final stage, the full team will draft recommendations to be disseminated through a variety of knowledge translation strategies. Meta-narrative synthesis has the unique capacity to expose the debates that are influencing the interpretation of empirical studies on vapour devices. We seek to "clear the air" with an even-handed review of the evidence and an understanding of the tensions within public health so that we can offer clear-headed recommendations for policy, regulation, and future research. PROSPERO CRD42015025267.
1993-02-10
new technology is to have sufficient control of processing to *- describable by an appropriate elecromagnetic model . build useful devices. For example...3. W aveguide Modulators .................................. 7 B. Integrated Optical Device and Circuit Modeling ... ................... .. 10 C...following categories: A. Integrated Optical Devices and Technology B. Integrated Optical Device and Circuit Modeling C. Cryogenic Etching for Low
System for characterizing semiconductor materials and photovoltaic devices through calibration
Sopori, Bhushan L.; Allen, Larry C.; Marshall, Craig; Murphy, Robert C.; Marshall, Todd
1998-01-01
A method and apparatus for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby.
System for characterizing semiconductor materials and photovoltaic devices through calibration
Sopori, B.L.; Allen, L.C.; Marshall, C.; Murphy, R.C.; Marshall, T.
1998-05-26
A method and apparatus are disclosed for measuring characteristics of a piece of material, typically semiconductor materials including photovoltaic devices. The characteristics may include dislocation defect density, grain boundaries, reflectance, external LBIC, internal LBIC, and minority carrier diffusion length. The apparatus includes a light source, an integrating sphere, and a detector communicating with a computer. The measurement or calculation of the characteristics is calibrated to provide accurate, absolute values. The calibration is performed by substituting a standard sample for the piece of material, the sample having a known quantity of one or more of the relevant characteristics. The quantity measured by the system of the relevant characteristic is compared to the known quantity and a calibration constant is created thereby. 44 figs.
Evaluation of the leap motion controller as a new contact-free pointing device.
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2014-12-24
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.
Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2015-01-01
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC. PMID:25609043
ERIC Educational Resources Information Center
Stuckey, Marc; Eilks, Ingo
2014-01-01
This paper presents a study on tattooing as a topic for chemistry education. The selection of the topic was inspired by a newly suggested framework, which focuses on the question of relevance of science education. The aim of this case was to get evidence on how topics selected based on the suggested model of relevance of science education affect…
Tuning the resistive switching properties of TiO2-x films
NASA Astrophysics Data System (ADS)
Ghenzi, N.; Rozenberg, M. J.; Llopis, R.; Levy, P.; Hueso, L. E.; Stoliar, P.
2015-03-01
We study the electrical characteristics of TiO2-x-based resistive switching devices fabricated with different oxygen/argon flow ratio during the oxide thin film sputtering deposition. Upon minute changes in this fabrication parameter, three qualitatively different device characteristics were accessed in the same system, namely, standard bipolar resistive switching, electroforming-free devices, and devices with multi-step breakdown. We propose that small variations in the oxygen/ argon flow ratio result in relevant changes of the oxygen vacancy concentration, which is the key parameter determining the resistive switching behavior. The coexistence of percolative or non-percolative conductive filaments is also discussed. Finally, the hypothesis is verified by means of the temperature dependence of the devices in low resistance state.
Cooling of superconducting devices by liquid storage and refrigeration unit
Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene
2013-08-20
A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.
Cohen, Noa; Sabhachandani, Pooja; Golberg, Alexander; Konry, Tania
2015-04-15
In this study we describe a simple lab-on-a-chip (LOC) biosensor approach utilizing well mixed microfluidic device and a microsphere-based assay capable of performing near real-time diagnostics of clinically relevant analytes such cytokines and antibodies. We were able to overcome the adsorption kinetics reaction rate-limiting mechanism, which is diffusion-controlled in standard immunoassays, by introducing the microsphere-based assay into well-mixed yet simple microfluidic device with turbulent flow profiles in the reaction regions. The integrated microsphere-based LOC device performs dynamic detection of the analyte in minimal amount of biological specimen by continuously sampling micro-liter volumes of sample per minute to detect dynamic changes in target analyte concentration. Furthermore we developed a mathematical model for the well-mixed reaction to describe the near real time detection mechanism observed in the developed LOC method. To demonstrate the specificity and sensitivity of the developed real time monitoring LOC approach, we applied the device for clinically relevant analytes: Tumor Necrosis Factor (TNF)-α cytokine and its clinically used inhibitor, anti-TNF-α antibody. Based on the reported results herein, the developed LOC device provides continuous sensitive and specific near real-time monitoring method for analytes such as cytokines and antibodies, reduces reagent volumes by nearly three orders of magnitude as well as eliminates the washing steps required by standard immunoassays. Copyright © 2014 Elsevier B.V. All rights reserved.
Feng, Qianmei
2007-10-01
Federal law mandates that every checked bag at all commercial airports be screened by explosive detection systems (EDS), explosive trace detection systems (ETD), or alternative technologies. These technologies serve as critical components of airport security systems that strive to reduce security risks at both national and global levels. To improve the operational efficiency and airport security, emerging image-based technologies have been developed, such as dual-energy X-ray (DX), backscatter X-ray (BX), and multiview tomography (MVT). These technologies differ widely in purchasing cost, maintenance cost, operating cost, processing rate, and accuracy. Based on a mathematical framework that takes into account all these factors, this article investigates two critical issues for operating screening devices: setting specifications for continuous security responses by different technologies; and selecting technology or combination of technologies for efficient 100% baggage screening. For continuous security responses, specifications or thresholds are used for classifying threat items from nonthreat items. By investigating the setting of specifications on system security responses, this article assesses the risk and cost effectiveness of various technologies for both single-device and two-device systems. The findings provide the best selection of image-based technologies for both single-device and two-device systems. Our study suggests that two-device systems outperform single-device systems in terms of both cost effectiveness and accuracy. The model can be readily extended to evaluate risk and cost effectiveness of multiple-device systems for airport checked-baggage security screening.
Learner-Adaptive Educational Technology for Simulation in Healthcare: Foundations and Opportunities.
Lineberry, Matthew; Dev, Parvati; Lane, H Chad; Talbot, Thomas B
2018-06-01
Despite evidence that learners vary greatly in their learning needs, practical constraints tend to favor ''one-size-fits-all'' educational approaches, in simulation-based education as elsewhere. Adaptive educational technologies - devices and/or software applications that capture and analyze relevant data about learners to select and present individually tailored learning stimuli - are a promising aid in learners' and educators' efforts to provide learning experiences that meet individual needs. In this article, we summarize and build upon the 2017 Society for Simulation in Healthcare Research Summit panel discussion on adaptive learning. First, we consider the role of adaptivity in learning broadly. We then outline the basic functions that adaptive learning technologies must implement and the unique affordances and challenges of technology-based approaches for those functions, sharing an illustrative example from healthcare simulation. Finally, we consider future directions for accelerating research, development, and deployment of effective adaptive educational technology and techniques in healthcare simulation.
Monte Carlo modeling of light-tissue interactions in narrow band imaging.
Le, Du V N; Wang, Quanzeng; Ramella-Roman, Jessica C; Pfefer, T Joshua
2013-01-01
Light-tissue interactions that influence vascular contrast enhancement in narrow band imaging (NBI) have not been the subject of extensive theoretical study. In order to elucidate relevant mechanisms in a systematic and quantitative manner we have developed and validated a Monte Carlo model of NBI and used it to study the effect of device and tissue parameters, specifically, imaging wavelength (415 versus 540 nm) and vessel diameter and depth. Simulations provided quantitative predictions of contrast-including up to 125% improvement in small, superficial vessel contrast for 415 over 540 nm. Our findings indicated that absorption rather than scattering-the mechanism often cited in prior studies-was the dominant factor behind spectral variations in vessel depth-selectivity. Narrow-band images of a tissue-simulating phantom showed good agreement in terms of trends and quantitative values. Numerical modeling represents a powerful tool for elucidating the factors that affect the performance of spectral imaging approaches such as NBI.
Bogdan Allemann, Inja; Kaufman, Joely
2011-01-01
Since the construction of the first laser in the 1960s, the role that lasers play in various medical specialities, including dermatology, has steadily increased. However, within the last 2 decades, the technological advances and the use of lasers in the field of dermatology have virtually exploded. Many treatments have only become possible with the use of lasers. Especially in aesthetic medicine, lasers are an essential tool in the treatment armamentarium. Due to better research and understanding of the physics of light and skin, there is now a wide and increasing array of different lasers and devices to choose from. The proper laser selection for each indication and treatment requires a profound understanding of laser physics and the basic laser principles. Understanding these principles will allow the laser operator to obtain better results and help avoid complications. This chapter will give an in-depth overview of the physical principles relevant in cutaneous laser surgery. Copyright © 2011 S. Karger AG, Basel.
Detection of magnetically enhanced cancer tumors using SQUID magnetometry: A feasibility study
NASA Astrophysics Data System (ADS)
Kenning, G. G.; Rodriguez, R.; Zotev, V. S.; Moslemi, A.; Wilson, S.; Hawel, L.; Byus, C.; Kovach, J. S.
2005-01-01
Nanoparticles bound to various biological molecules and pharmacological agents can be administered systemically, to humans without apparent toxicity. This opens an era in the targeting of specific tissues and disease processes for noninvasive imaging and treatment. An important class of particles used predominantly for magnetic resonance imaging is based on iron-oxide ferrites. We performed computer simulations using experimentally determined values for concentrations of superparamagnetic particles achievable in specific tissues of the mouse in vivo and concentrations of particles linked to monoclonal antibodies specific to antigens of two human cancer cell lines in vitro. An instrument to target distance of 12cm, into the body, was selected as relevant to our goal of developing a rapid inexpensive method of scanning the body for occult disease. The simulations demonstrate the potential feasibility of superconducting quantum interference device magnetometry to detect induced magnetic fields in focal concentrations of superparamagnetic particles targeted, in vivo, to sites of disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, Bryon W.; Reid, Obadiah G.; Coffey, David C.
2016-09-26
Photoinduced charge generation (PCG) dynamics are notoriously difficult to correlate with specific molecular properties in device relevant polymer:fullerene organic photovoltaic blend films due to the highly complex nature of the solid state blend morphology. Here, this study uses six judiciously selected trifluoromethylfullerenes blended with the prototypical polymer poly(3-hexylthiophene) and measure the PCG dynamics in 50 fs-500 ns time scales with time-resolved microwave conductivity and femtosecond transient absorption spectroscopy. The isomeric purity and thorough chemical characterization of the fullerenes used in this study allow for a detailed correlation between molecular properties, driving force, local intermolecular electronic coupling and, ultimately, the efficiencymore » of PCG yield. The findings show that the molecular design of the fullerene not only determines inter-fullerene electronic coupling, but also influences the decay dynamics of free holes in the donor phase even when the polymer microstructure remains unchanged.« less
NASA Astrophysics Data System (ADS)
Hammerschmidt, Ulf; Hameury, Jacques; Strnad, Radek; Turzó-Andras, Emese; Wu, Jiyu
2015-07-01
This paper presents a critical review of current industrial techniques and instruments to measure the thermal conductivity of thermal insulation materials, especially those insulations that can operate at temperatures above and up to . These materials generally are of a porous nature. The measuring instruments dealt with here are selected based on their maximum working temperature that should be higher than at least . These instruments are special types of the guarded hot-plate apparatus, the guarded heat-flow meter, the transient hot-wire and hot-plane instruments as well as the laser/xenon flash devices. All technical characteristics listed are quoted from the generally accessible information of the relevant manufacturers. The paper includes rankings of the instruments according to their standard retail price, the maximum sample size, and maximum working temperature, as well as the minimum in their measurement range.
The effects of innovation factors on smartphone adoption among nurses in community hospitals.
Putzer, Gavin J; Park, Yangil
2010-01-01
A relatively new mobile technological device is the smartphone-a phone with advanced features such as Windows Mobile software, access to the Internet, and other computer processing capabilities. This article investigates the decision to adopt a smartphone among healthcare professionals, specifically nurses. The study examines constructs that affect an individual's decision to adopt a smartphone by employing innovation attributes leading to perceived attitudes. We hypothesize that individual intentions to use a smartphone are mostly determined by attitudes toward using a smartphone, which in turn are affected by innovation characteristics. Innovation characteristics are factors that help explain whether a user will adopt a new technology. The study consisted of a survey disseminated to 200 practicing nurses selected from two community hospitals in the southeastern United States. In our model, the innovation characteristics of observability, compatibility, job relevance, internal environment, and external environment were significant predictors of attitude toward using a smartphone.
#DocsOnTwitter: How Physicians use Social Media to Build Social Capital.
Hanzel, Taylor; Richards, Jessica; Schwitters, Paige; Smith, Kirsten; Wendland, Kyle; Martin, Jamie; Keltgen, Jaciel
2018-01-01
Using social capital theory, Augustana University healthcare marketing students examined how medical professionals utilize social media to further engage with their communities. The team selected Twitter as the social media network from which to collect data because of its popularity and ease of use. The sample was drawn from 1,000 Twitter profiles that were retrieved from 24 keywords such as MD. A total of 3,378,285 tweets from this sample were collected and analyzed for content, use of hashtags, mobile device use, frequency, longevity, medical relevance, medical specialty, gender, and approximate age. This is an important first look, using Big Data, at how physicians parlay the popularity of social media to build social capital through sharing research with colleagues, connecting with patients and prospective patients, and extending their personal and employer brands to increasingly information-hungry and interactive consumers.
Klepárník, Karel
2015-01-01
This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices with MS detection and identification. A wide selection of 183 relevant articles covers the literature published from June 2012 till May 2014 as a continuation of the review article on the same topic by Kleparnik [Electrophoresis 2013, 34, 70-86]. Special attention is paid to the new improvements in the theory of instrumentation and methodology of MS interfacing with capillary versions of zone electrophoresis, ITP, and IEF. Ionization methods in MS include ESI, MALDI, and ICP. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography and micellar electrokinetic chromatography are not included. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert
2017-07-01
To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability and validity. Relevant instruments were then selected in a consensus round by 11 knowledge brokers who were responsible for the implementation of the selected instruments. The feasibility of the selected instruments was tested by 36 physical therapists at different work settings within stroke services. Finally, instruments that were deemed relevant and feasible were included in the revised guideline. A total of 28 instruments were recommended for inclusion in the revised guideline. Nineteen instruments were retained from the previous guideline. Ten new instruments were tested in clinical practice, seven of which were found feasible. Two more instruments were added after critical appraisal of the set of the measurement instruments. The revised guideline contains 28 relevant and feasible instrument selected and tested in clinical practice by physical therapists. Further education and implementation is needed to integrate instruments in clinical practice. Further research is proposed for developing and implementing a core set of measurement instruments to be used at fixed time points to establish data registries that allow for continuous improvement of rehabilitation for stroke patients. Implications for Rehabilitation The revised Dutch Stroke Physical Therapy Guideline recommends a total of 28 instruments, that are relevant and feasible for clinical practice of physical therapist in the different settings of stroke rehabilitation. The selection of instrument in daily practice should be part of the clinical reasoning process of PTs and be tailored to individual patients' needs and the degree of priority of the affected ICF category. Suggested education strategies for further integration of instruments in of the daily practice of PTs in Stroke Rehabilitation are: 'Training on the job' and 'peer assessment in clinical situations'.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradshaw, Nathan P.; Severt, Sean Y.; Wang, Zhaoying
Biocompatible materials capable of controlled actuation under biologically relevant conditions are in high demand for use in a number of biomedical applications. Recently, we demonstrated that a composite material composed of silk biopolymer and the conducting polymer poly(pyrrole) can bend under an applied voltage using a simple bilayer device. Here we present further characterization of these bilayer actuators using time of flight secondary ion mass spectrometry, and provide clarification on the mechanism of actuation and factors affecting device performance and stability. We will discuss the results of this study in the context of strategies for optimization of device performance.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-11
... vasculature via partial occlusion of the descending aorta, including in patients with acute ischemic stroke... device is placed in the descending aorta. On March 30, 2005, a Humanitarian Device Exemption application... selectively stopping or controlling flow in the peripheral vasculature, which includes the descending aorta...
Power selective optical filter devices and optical systems using same
Koplow, Jeffrey P
2014-10-07
In an embodiment, a power selective optical filter device includes an input polarizer for selectively transmitting an input signal. The device includes a wave-plate structure positioned to receive the input signal, which includes at least one substantially zero-order, zero-wave plate. The zero-order, zero-wave plate is configured to alter a polarization state of the input signal passing in a manner that depends on the power of the input signal. The zero-order, zero-wave plate includes an entry and exit wave plate each having a fast axis, with the fast axes oriented substantially perpendicular to each other. Each entry wave plate is oriented relative to a transmission axis of the input polarizer at a respective angle. An output polarizer is positioned to receive a signal output from the wave-plate structure and selectively transmits the signal based on the polarization state.
Radiation area monitor device and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vencelj, Matjaz; Stowe, Ashley C.; Petrovic, Toni
A radiation area monitor device/method, utilizing: a radiation sensor having a directional radiation sensing capability; a rotation mechanism operable for selectively rotating the radiation sensor such that the directional radiation sensing capability selectively sweeps an area of interest; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the directional radiation sensing capability selectively sweeps the area of interest. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor; and amore » second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.« less
Method of Controlling Steering of a Ground Vehicle
NASA Technical Reports Server (NTRS)
Guo, Raymond (Inventor); Atluri, Venkata Prasad (Inventor); Bluethmann, William J. (Inventor); Lee, Chunhao J. (Inventor); Vitale, Robert L. (Inventor); Dawson, Andrew D. (Inventor)
2016-01-01
A method of controlling steering of a vehicle through setting wheel angles of a plurality of modular electronic corner assemblies (eModules) is provided. The method includes receiving a driving mode selected from a mode selection menu. A position of a steering input device is determined in a master controller. A velocity of the vehicle is determined, in the master controller, when the determined position of the steering input device is near center. A drive mode request corresponding to the selected driving mode to the plurality of steering controllers is transmitted to the master controller. A required steering angle of each of the plurality of eModules is determined, in the master controller, as a function of the determined position of the steering input device, the determined velocity of the vehicle, and the selected first driving mode. The eModules are set to the respective determined steering angles.
Color selective photodetector and methods of making
Walker, Brian J.; Dorn, August; Bulovic, Vladimir; Bawendi, Moungi G.
2013-03-19
A photoelectric device, such as a photodetector, can include a semiconductor nanowire electrostatically associated with a J-aggregate. The J-aggregate can facilitate absorption of a desired wavelength of light, and the semiconductor nanowire can facilitate charge transport. The color of light detected by the device can be chosen by selecting a J-aggregate with a corresponding peak absorption wavelength.
A Selection System and Catalog for Instructional Media and Devices.
ERIC Educational Resources Information Center
Boucher, Brian G.; And Others
A system is presented which facilitates the selection of training media and devices based on the requirements of specific learning objectives. The system consists of the use of a set of descriptive parameters which are common to both learning objectives and media. The system allows the essential intent of learning objectives to be analyzed in…
Best, Catherine A; Yim, Hyungwook; Sloutsky, Vladimir M
2013-10-01
Selective attention plays an important role in category learning. However, immaturities of top-down attentional control during infancy coupled with successful category learning suggest that early category learning is achieved without attending selectively. Research presented here examines this possibility by focusing on category learning in infants (6-8months old) and adults. Participants were trained on a novel visual category. Halfway through the experiment, unbeknownst to participants, the to-be-learned category switched to another category, where previously relevant features became irrelevant and previously irrelevant features became relevant. If participants attend selectively to the relevant features of the first category, they should incur a cost of selective attention immediately after the unknown category switch. Results revealed that adults demonstrated a cost, as evidenced by a decrease in accuracy and response time on test trials as well as a decrease in visual attention to newly relevant features. In contrast, infants did not demonstrate a similar cost of selective attention as adults despite evidence of learning both to-be-learned categories. Findings are discussed as supporting multiple systems of category learning and as suggesting that learning mechanisms engaged by adults may be different from those engaged by infants. Copyright © 2013 Elsevier Inc. All rights reserved.
Age-equivalent top-down modulation during cross-modal selective attention.
Guerreiro, Maria J S; Anguera, Joaquin A; Mishra, Jyoti; Van Gerven, Pascal W M; Gazzaley, Adam
2014-12-01
Selective attention involves top-down modulation of sensory cortical areas, such that responses to relevant information are enhanced whereas responses to irrelevant information are suppressed. Suppression of irrelevant information, unlike enhancement of relevant information, has been shown to be deficient in aging. Although these attentional mechanisms have been well characterized within the visual modality, little is known about these mechanisms when attention is selectively allocated across sensory modalities. The present EEG study addressed this issue by testing younger and older participants in three different tasks: Participants attended to the visual modality and ignored the auditory modality, attended to the auditory modality and ignored the visual modality, or passively perceived information presented through either modality. We found overall modulation of visual and auditory processing during cross-modal selective attention in both age groups. Top-down modulation of visual processing was observed as a trend toward enhancement of visual information in the setting of auditory distraction, but no significant suppression of visual distraction when auditory information was relevant. Top-down modulation of auditory processing, on the other hand, was observed as suppression of auditory distraction when visual stimuli were relevant, but no significant enhancement of auditory information in the setting of visual distraction. In addition, greater visual enhancement was associated with better recognition of relevant visual information, and greater auditory distractor suppression was associated with a better ability to ignore auditory distraction. There were no age differences in these effects, suggesting that when relevant and irrelevant information are presented through different sensory modalities, selective attention remains intact in older age.
Methods and devices for high-throughput dielectrophoretic concentration
Simmons, Blake A.; Cummings, Eric B.; Fiechtner, Gregory J.; Fintschenko, Yolanda; McGraw, Gregory J.; Salmi, Allen
2010-02-23
Disclosed herein are methods and devices for assaying and concentrating analytes in a fluid sample using dielectrophoresis. As disclosed, the methods and devices utilize substrates having a plurality of pores through which analytes can be selectively prevented from passing, or inhibited, on application of an appropriate electric field waveform. The pores of the substrate produce nonuniform electric field having local extrema located near the pores. These nonuniform fields drive dielectrophoresis, which produces the inhibition. Arrangements of electrodes and porous substrates support continuous, bulk, multi-dimensional, and staged selective concentration.
Ma, Long; Wu, Guanrong; Li, Yufeng; Qin, Ping; Meng, Lingpei; Liu, Haiyan; Li, Yuyin; Diao, Aipo
2015-11-21
We constructed a reversible molecular device in the nanoscale based on a DNA three-way junction (3WJ) fueled by Hg(2+) binding and sequestration. It is highly responsive to external stimuli, which brings about optically detectable global structural changes. Such a DNA device can serve as a novel "turn-on and -off" fluorescent sensor for Hg(2+) and biothiol detection with high selectivity and sensitivity.
Tsuo, Y. Simon; Deb, Satyen K.
1990-01-01
Disclosed is a hydrogen ion microlithography process for use in microelectronic fabrication and semiconductor device processing. The process comprises the steps of providing a single layer of either an amorphous silicon or hydrogenated amorphous silicon material. A pattern is recorded in a selected layer of amorphous silicon or hydrogenated amorphous silicon materials by preferentially implanting hydrogen ions therein so as to permit the selected layer to serve as a mask-resist wafer suitable for subsequent development and device fabrication. The layer is developed to provide a surface pattern therein adaptable for subsequent use in microelectronic fabrication and semiconductor device processing.
Flynn, Sheryl; Palma, Phyllis; Bender, Anneke
2007-12-01
Many Americans live with physical functional limitations stemming from stroke. These functional limitations can be reduced by task-specific training that is repetitive, motivating, and augmented with feedback. Virtual reality (VR) is reported to offer an engaging environment that is repetitive, safe, motivating, and gives task-specific feedback. The purpose of this case report was to explore the use of a low-cost VR device [Sony PlayStation 2 (PS2) EyeToy] for an individual in the chronic phase of stroke recovery. An individual two years poststroke with residual sensorimotor deficits completed 20 one-hour sessions using the PS2 EyeToy. The game's task requirements included target-based motion, dynamic balance, and motor planning. The feasibility of using the gaming platform was explored and a broad selection of outcomes was used to assess change in performance. Device use was feasible. Clinically relevant improvements were found on the Dynamic Gait Index and trends toward improvement on the Fugl-Meyer Assessment, Berg Balance Scale, UE Functional Index, Motor Activity Log, and Beck Depression Inventory. A low-cost VR system was easily used in the home. In the future it may be used to improve sensory/motor recovery following stroke as an adjunct to standard care physical therapy.
Funding for the 2ND IAEA technical meeting on fusion data processing, validation and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenwald, Martin
The International Atomic Energy Agency (IAEA) will organize the second Technical Meeting on Fusion Da Processing, Validation and Analysis from 30 May to 02 June, 2017, in Cambridge, MA USA. The meeting w be hosted by the MIT Plasma Science and Fusion Center (PSFC). The objective of the meeting is to provide a platform where a set of topics relevant to fusion data processing, validation and analysis are discussed with the view of extrapolation needs to next step fusion devices such as ITER. The validation and analysis of experimental data obtained from diagnostics used to characterize fusion plasmas are crucialmore » for a knowledge based understanding of the physical processes governing the dynamics of these plasmas. The meeting will aim at fostering, in particular, discussions of research and development results that set out or underline trends observed in the current major fusion confinement devices. General information on the IAEA, including its mission and organization, can be found at the IAEA websit Uncertainty quantification (UQ) Model selection, validation, and verification (V&V) Probability theory and statistical analysis Inverse problems & equilibrium reconstru ction Integrated data analysis Real time data analysis Machine learning Signal/image proc essing & pattern recognition Experimental design and synthetic diagnostics Data management« less
Castillo-Cara, Manuel; Lovón-Melgarejo, Jesús; Bravo-Rocca, Gusseppe; Orozco-Barbosa, Luis; García-Varea, Ismael
2017-01-01
Nowadays, there is a great interest in developing accurate wireless indoor localization mechanisms enabling the implementation of many consumer-oriented services. Among the many proposals, wireless indoor localization mechanisms based on the Received Signal Strength Indication (RSSI) are being widely explored. Most studies have focused on the evaluation of the capabilities of different mobile device brands and wireless network technologies. Furthermore, different parameters and algorithms have been proposed as a means of improving the accuracy of wireless-based localization mechanisms. In this paper, we focus on the tuning of the RSSI fingerprint to be used in the implementation of a Bluetooth Low Energy 4.0 (BLE4.0) Bluetooth localization mechanism. Following a holistic approach, we start by assessing the capabilities of two Bluetooth sensor/receiver devices. We then evaluate the relevance of the RSSI fingerprint reported by each BLE4.0 beacon operating at various transmission power levels using feature selection techniques. Based on our findings, we use two classification algorithms in order to improve the setting of the transmission power levels of each of the BLE4.0 beacons. Our main findings show that our proposal can greatly improve the localization accuracy by setting a custom transmission power level for each BLE4.0 beacon. PMID:28590413
Castillo-Cara, Manuel; Lovón-Melgarejo, Jesús; Bravo-Rocca, Gusseppe; Orozco-Barbosa, Luis; García-Varea, Ismael
2017-06-07
Nowadays, there is a great interest in developing accurate wireless indoor localization mechanisms enabling the implementation of many consumer-oriented services. Among the many proposals, wireless indoor localization mechanisms based on the Received Signal Strength Indication (RSSI) are being widely explored. Most studies have focused on the evaluation of the capabilities of different mobile device brands and wireless network technologies. Furthermore, different parameters and algorithms have been proposed as a means of improving the accuracy of wireless-based localization mechanisms. In this paper, we focus on the tuning of the RSSI fingerprint to be used in the implementation of a Bluetooth Low Energy 4.0 (BLE4.0) Bluetooth localization mechanism. Following a holistic approach, we start by assessing the capabilities of two Bluetooth sensor/receiver devices. We then evaluate the relevance of the RSSI fingerprint reported by each BLE4.0 beacon operating at various transmission power levels using feature selection techniques. Based on our findings, we use two classification algorithms in order to improve the setting of the transmission power levels of each of the BLE4.0 beacons. Our main findings show that our proposal can greatly improve the localization accuracy by setting a custom transmission power level for each BLE4.0 beacon.
Jamiolkowski, Megan A.; Pedersen, Drake D.; Wu, Wei-Tao; Antaki, James F.; Wagner, William R.
2016-01-01
The blood flow pathway within a device, together with the biomaterial surfaces and status of the patient’s blood, are well-recognized factors in the development of thrombotic deposition and subsequent embolization. Blood flow patterns are of particular concern for devices such as blood pumps (i.e. ventricular assist devices, VADs) where shearing forces can be high, volumes are relatively large, and the flow fields can be complex. However, few studies have examined the effect of geometric irregularities on thrombus formation on clinically relevant opaque materials under flow. The objective of this study was to quantify human platelet deposition onto Ti6Al4V alloys, as well as positive and negative control surfaces, in the region of defined crevices (~50–150 µm in width) that might be encountered in many VADs or other cardiovascular devices. To achieve this, reconstituted fresh human blood with hemoglobin-depleted red blood cells (to achieve optical clarity while maintaining relevant rheology), long working optics, and a custom designed parallel plate flow chamber were employed. The results showed that the least amount of platelet deposition occurred in the largest crevice size examined, which was counterintuitive. The greatest levels of deposition occurred in the 90 µm and 53 µm crevices at the lower wall shear rate. The results suggest that while crevices may be unavoidable in device manufacturing, the crevice size might be tailored, depending on the flow conditions, to reduce the risk of thromboembolic events. Further, these data might be used to improve the accuracy of predictive models of thrombotic deposition in cardiovascular devices to help optimize the blood flow path and reduce device thrombogenicity. PMID:27156141
Age Differences in Selective Memory of Goal-Relevant Stimuli Under Threat.
Durbin, Kelly A; Clewett, David; Huang, Ringo; Mather, Mara
2018-02-01
When faced with threat, people often selectively focus on and remember the most pertinent information while simultaneously ignoring any irrelevant information. Filtering distractors under arousal requires inhibitory mechanisms, which take time to recruit and often decline in older age. Despite the adaptive nature of this ability, relatively little research has examined how both threat and time spent preparing these inhibitory mechanisms affect selective memory for goal-relevant information across the life span. In this study, 32 younger and 31 older adults were asked to encode task-relevant scenes, while ignoring transparent task-irrelevant objects superimposed onto them. Threat levels were increased on some trials by threatening participants with monetary deductions if they later forgot scenes that followed threat cues. We also varied the time between threat induction and a to-be-encoded scene (i.e., 2 s, 4 s, 6 s) to determine whether both threat and timing effects on memory selectivity differ by age. We found that age differences in memory selectivity only emerged after participants spent a long time (i.e., 6 s) preparing for selective encoding. Critically, this time-dependent age difference occurred under threatening, but not neutral, conditions. Under threat, longer preparation time led to enhanced memory for task-relevant scenes and greater memory suppression of task-irrelevant objects in younger adults. In contrast, increased preparation time after threat induction had no effect on older adults' scene memory and actually worsened memory suppression of task-irrelevant objects. These findings suggest that increased time to prepare top-down encoding processes benefits younger, but not older, adults' selective memory for goal-relevant information under threat. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Heuer, Anna; Schubö, Anna
2016-01-01
Visual working memory can be modulated according to changes in the cued task relevance of maintained items. Here, we investigated the mechanisms underlying this modulation. In particular, we studied the consequences of attentional selection for selected and unselected items, and the role of individual differences in the efficiency with which attention is deployed. To this end, performance in a visual working memory task as well as the CDA/SPCN and the N2pc, ERP components associated with visual working memory and attentional processes, were analysed. Selection during the maintenance stage was manipulated by means of two successively presented retrocues providing spatial information as to which items were most likely to be tested. Results show that attentional selection serves to robustly protect relevant representations in the focus of attention while unselected representations which may become relevant again still remain available. Individuals with larger retrocueing benefits showed higher efficiency of attentional selection, as indicated by the N2pc, and showed stronger maintenance-associated activity (CDA/SPCN). The findings add to converging evidence that focused representations are protected, and highlight the flexibility of visual working memory, in which information can be weighted according its relevance.
Method of App Selection for Healthcare Providers Based on Consumer Needs.
Lee, Jisan; Kim, Jeongeun
2018-01-01
Mobile device applications can be used to manage health. However, healthcare providers hesitate to use them because selection methods that consider the needs of health consumers and identify the most appropriate application are rare. This study aimed to create an effective method of identifying applications that address user needs. Women experiencing dysmenorrhea and premenstrual syndrome were the targeted users. First, we searched for related applications from two major sources of mobile applications. Brainstorming, mind mapping, and persona and scenario techniques were used to create a checklist of relevant criteria, which was used to rate the applications. Of the 2784 applications found, 369 were analyzed quantitatively. Of those, five of the top candidates were evaluated by three groups: application experts, clinical experts, and potential users. All three groups ranked one application the highest; however, the remaining rankings differed. The results of this study suggest that the method created is useful because it considers not only the needs of various users but also the knowledge of application and clinical experts. This study proposes a method for finding and using the best among existing applications and highlights the need for nurses who can understand and combine opinions of users and application and clinical experts.
Advancements in text-to-speech technology and implications for AAC applications
NASA Astrophysics Data System (ADS)
Syrdal, Ann K.
2003-10-01
Intelligibility was the initial focus in text-to-speech (TTS) research, since it is clearly a necessary condition for the application of the technology. Sufficiently high intelligibility (approximating human speech) has been achieved in the last decade by the better formant-based and concatenative TTS systems. This led to commercially available TTS systems for highly motivated users, particularly the blind and vocally impaired. Some unnatural qualities of TTS were exploited by these users, such as very fast speaking rates and altered pitch ranges for flagging relevant information. Recently, the focus in TTS research has turned to improving naturalness, so that synthetic speech sounds more human and less robotic. Unit selection approaches to concatenative synthesis have dramatically improved TTS quality, although at the cost of larger and more complex systems. This advancement in naturalness has made TTS technology more acceptable to the general public. The vocally impaired appreciate a more natural voice with which to represent themselves when communicating with others. Unit selection TTS does not achieve such high speaking rates as the earlier TTS systems, however, which is a disadvantage to some AAC device users. An important new research emphasis is to improve and increase the range of emotional expressiveness of TTS.
CMOS compatible electrode materials selection in oxide-based memory devices
NASA Astrophysics Data System (ADS)
Zhuo, V. Y.-Q.; Li, M.; Guo, Y.; Wang, W.; Yang, Y.; Jiang, Y.; Robertson, J.
2016-07-01
Electrode materials selection guidelines for oxide-based memory devices are constructed from the combined knowledge of observed device operation characteristics, ab-initio calculations, and nano-material characterization. It is demonstrated that changing the top electrode material from Ge to Cr to Ta in the Ta2O5-based memory devices resulted in a reduction of the operation voltages and current. Energy Dispersed X-ray (EDX) Spectrometer analysis clearly shows that the different top electrode materials scavenge oxygen ions from the Ta2O5 memory layer at various degrees, leading to different oxygen vacancy concentrations within the Ta2O5, thus the observed trends in the device performance. Replacing the Pt bottom electrode material with CMOS compatible materials (Ru and Ir) further reduces the power consumption and can be attributed to the modification of the Schottky barrier height and oxygen vacancy concentration at the electrode/oxide interface. Both trends in the device performance and EDX results are corroborated by the ab-initio calculations which reveal that the electrode material tunes the oxygen vacancy concentration via the oxygen chemical potential and defect formation energy. This experimental-theoretical approach strongly suggests that the proper selection of CMOS compatible electrode materials will create the critical oxygen vacancy concentration to attain low power memory performance.
Two-color mixing for classifying agricultural products for safety and quality
NASA Astrophysics Data System (ADS)
Ding, Fujian; Chen, Yud-Ren; Chao, Kuanglin; Chan, Diane E.
2006-02-01
We show that the chromaticness of the visual signal that results from the two-color mixing achieved through an optically enhanced binocular device is directly related to the band ratio of light intensity at the two selected wavebands. A technique that implements the band-ratio criterion in a visual device by using two-color mixing is presented here. The device will allow inspectors to identify targets visually in accordance with a two-wavelength band ratio. It is a method of inspection by human vision assisted by an optical device, which offers greater flexibility and better cost savings than a multispectral machine vision system that implements the band-ratio criterion. With proper selection of the two narrow wavebands, discrimination by chromaticness that is directly related to the band ratio can work well. An example application of this technique for the inspection of carcasses chickens of afficted with various diseases is given. An optimal pair of wavelengths of 454 and 578 nm was selected to optimize differences in saturation and hue in CIE LUV color space among different types of target. Another example application, for the detection of chilling injury in cucumbers, is given, here the selected wavelength pair was 504 and 652 nm. The novel two-color mixing technique for visual inspection can be included in visual devices for various applications, ranging from target detection to food safety inspection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conway de Macario, E.; Macario, A.J.L.; Wolin, M.J.
1988-01-01
A major contribution of this research has been a significant advance of the immunology of methanogens and other archaebacteria (e.g., extreme halophiles). The foundations have been laid to begin the immunologic study of microbes which are non-methanogens themselves but are important for the fermentation process. This work helped to make clear that bacterial immunology goes beyond the study of pathogens for man, animals, or plants. Immunology can be applied successfully to the study of isolates of importance to understand evolution, phylogeny, ecology, bio-conversion systems, and to advance methanogenic biotechnology. Immunology holds considerable potential to aid in genetic and genetic engineeringmore » manipulations as well as in in situ handling of microbes relevant to methanogenesis. Thus, antibodies can help in the discovery of useful microbes, the generation of improved stains, the selection of desirable microorganisms, and in the monitoring and controlling of bioreactors. Immunogolic work in this new field should generate knowledge and devices relevant to areas such as Biological Energy Research, Ecology of Microorganisms, and Environmental (Sanitary) Engineering. In this regard, this work has contributed a comprehensive antiserum bank, a large panel of calibrated polyclonal antibody probes, and techniques for producing and utilizing these probes in the study of methanogens and related bacteria. 67 refs.« less
Crutzen, Rik; Peters, Gjalt-Jorn Ygram; Noijen, Judith
2017-01-01
When developing an intervention aimed at behavior change, one of the crucial steps in the development process is to select the most relevant social-cognitive determinants. These determinants can be seen as the buttons one needs to push to establish behavior change. Insight into these determinants is needed to select behavior change methods (i.e., general behavior change techniques that are applied in an intervention) in the development process. Therefore, a study on determinants is often conducted as formative research in the intervention development process. Ideally, all relevant determinants identified in such a study are addressed by an intervention. However, when developing a behavior change intervention, there are limits in terms of, for example, resources available for intervention development and the amount of content that participants of an intervention can be exposed to. Hence, it is important to select those determinants that are most relevant to the target behavior as these determinants should be addressed in an intervention. The aim of the current paper is to introduce a novel approach to select the most relevant social-cognitive determinants and use them in intervention development. This approach is based on visualization of confidence intervals for the means and correlation coefficients for all determinants simultaneously. This visualization facilitates comparison, which is necessary when making selections. By means of a case study on the determinants of using a high dose of 3,4-methylenedioxymethamphetamine (commonly known as ecstasy), we illustrate this approach. We provide a freely available tool to facilitate the analyses needed in this approach.
A general framework to learn surrogate relevance criterion for atlas based image segmentation
NASA Astrophysics Data System (ADS)
Zhao, Tingting; Ruan, Dan
2016-09-01
Multi-atlas based image segmentation sees great opportunities in the big data era but also faces unprecedented challenges in identifying positive contributors from extensive heterogeneous data. To assess data relevance, image similarity criteria based on various image features widely serve as surrogates for the inaccessible geometric agreement criteria. This paper proposes a general framework to learn image based surrogate relevance criteria to better mimic the behaviors of segmentation based oracle geometric relevance. The validity of its general rationale is verified in the specific context of fusion set selection for image segmentation. More specifically, we first present a unified formulation for surrogate relevance criteria and model the neighborhood relationship among atlases based on the oracle relevance knowledge. Surrogates are then trained to be small for geometrically relevant neighbors and large for irrelevant remotes to the given targets. The proposed surrogate learning framework is verified in corpus callosum segmentation. The learned surrogates demonstrate superiority in inferring the underlying oracle value and selecting relevant fusion set, compared to benchmark surrogates.
Inter-device differences in monitoring for goal-directed fluid therapy.
Thiele, Robert H; Bartels, Karsten; Gan, Tong-Joo
2015-02-01
Goal-directed fluid therapy is an integral component of many Enhanced Recovery After Surgery (ERAS) protocols currently in use. The perioperative clinician is faced with a myriad of devices promising to deliver relevant physiologic data to better guide fluid therapy. The goal of this review is to provide concise information to enable the clinician to make an informed decision when choosing a device to guide goal-directed fluid therapy. The focus of many devices used for advanced hemodynamic monitoring is on providing measurements of cardiac output, while other, more recent, devices include estimates of fluid responsiveness based on dynamic indices that better predict an individual's response to a fluid bolus. Currently available technologies include the pulmonary artery catheter, esophageal Doppler, arterial waveform analysis, photoplethysmography, venous oxygen saturation, as well as bioimpedance and bioreactance. The underlying mechanistic principles for each device are presented as well as their performance in clinical trials relevant for goal-directed therapy in ERAS. The ERAS protocols typically involve a multipronged regimen to facilitate early recovery after surgery. Optimizing perioperative fluid therapy is a key component of these efforts. While no technology is without limitations, the majority of the currently available literature suggests esophageal Doppler and arterial waveform analysis to be the most desirable choices to guide fluid administration. Their performance is dependent, in part, on the interpretation of dynamic changes resulting from intrathoracic pressure fluctuations encountered during mechanical ventilation. Evolving practice patterns, such as low tidal volume ventilation as well as the necessity to guide fluid therapy in spontaneously breathing patients, will require further investigation.
NASA Astrophysics Data System (ADS)
Lee, J.-H.; Houk, R. T. J.; Robinson, A.; Greathouse, J. A.; Thornberg, S. M.; Allendorf, M. D.; Hesketh, P. J.
2010-04-01
In this paper we demonstrate the potential for novel nanoporous framework materials (NFM) such as metal-organic frameworks (MOFs) to provide selectivity and sensitivity to a broad range of analytes including explosives, nerve agents, and volatile organic compounds (VOCs). NFM are highly ordered, crystalline materials with considerable synthetic flexibility resulting from the presence of both organic and inorganic components within their structure. Detection of chemical weapons of mass destruction (CWMD), explosives, toxic industrial chemicals (TICs), and volatile organic compounds (VOCs) using micro-electro-mechanical-systems (MEMS) devices, such as microcantilevers and surface acoustic wave sensors, requires the use of recognition layers to impart selectivity. Traditional organic polymers are dense, impeding analyte uptake and slowing sensor response. The nanoporosity and ultrahigh surface areas of NFM enhance transport into and out of the NFM layer, improving response times, and their ordered structure enables structural tuning to impart selectivity. Here we describe experiments and modeling aimed at creating NFM layers tailored to the detection of water vapor, explosives, CWMD, and VOCs, and their integration with the surfaces of MEMS devices. Force field models show that a high degree of chemical selectivity is feasible. For example, using a suite of MOFs it should be possible to select for explosives vs. CWMD, VM vs. GA (nerve agents), and anthracene vs. naphthalene (VOCs). We will also demonstrate the integration of various NFM with the surfaces of MEMS devices and describe new synthetic methods developed to improve the quality of VFM coatings. Finally, MOF-coated MEMS devices show how temperature changes can be tuned to improve response times, selectivity, and sensitivity.
Ramezany, Alireza; Pourkamali, Siavash
2018-04-11
Channel-selective filtering and amplification in ultrahigh frequency (UHF) receiver front-ends are crucial for realization of cognitive radio systems and the future of wireless communication. In the past decade, there have been significant advances in the performance of microscale electromechanical resonant devices. However, such devices have not yet been able to meet the requirements for direct channel selection at RF. They also occupy a relatively large area on the chip making implementation of large arrays to cover several frequency bands challenging. On the other hand, electromechanical piezoresistive resonant devices are active devices that have recently shown the possibility of simultaneous signal amplification and channel-select filtering at lower frequencies. It has been theoretically predicted that if scaled down into the nanoscale, they can operate in the UHF range with a very low power consumption. Here, for the first time nanomechanical piezoresistive amplifiers with active element dimensions as small as 50 nm × 200 nm are demonstrated. With a device area of less than 1.5 μm 2 a piezoresistive amplifier operating at 730 MHz shows effective quality factor ( Q) of 89,000 for a 50Ω load and gains as high as 10 dB and Q of 330,000 for a 250Ω load while consuming 189 μW of power. On the basis of the measurement results, it is shown that for piezoresistor dimensions of 30 nm × 100 nm it is possible to get a similar performance at 2.4 GHz with device footprint of less than 0.2 μm 2 .
Elliptically polarizing adjustable phase insertion device
Carr, R.
1995-01-17
An insertion device for extracting polarized electromagnetic energy from a beam of particles is disclosed. The insertion device includes four linear arrays of magnets which are aligned with the particle beam. The magnetic field strength to which the particles are subjected is adjusted by altering the relative alignment of the arrays in a direction parallel to that of the particle beam. Both the energy and polarization of the extracted energy may be varied by moving the relevant arrays parallel to the beam direction. The present invention requires a substantially simpler and more economical superstructure than insertion devices in which the magnetic field strength is altered by changing the gap between arrays of magnets. 3 figures.
Security and Dependability Solutions for Networks and Devices
NASA Astrophysics Data System (ADS)
Gücrgens, Sigrid; Fuchs, Andreas
In this chapter we give an overview over the denotation of the SERENITY artefacts S&D Classes, Patterns and Implementations in the context of networks and devices. In order to demonstrate their necessity we sketch an example for confidential and authentic communication and storage that utilizes a trusted platform module, and model the relevant pattern. We then dissociate solutions for network and device related S&D requirements from those targeting the context of organizational or workflow and web services based solutions. Then we give a summary of the broad field of application for network and device solutions. Finally we clarify the meaning and interaction between classes, patterns and implementations by giving some concrete examples.
ERIC Educational Resources Information Center
Ostroff, Daniel; Shneiderman, Ben
1988-01-01
Describes a study that measured the speed, error rates, and subjective evaluation of arrow jump keys, a jump mouse, number keys, and a touch screen in an interactive encyclopedia. The results of previous studies are discussed as well as the findings of this study. Improvements in selection devices are suggested. (41 references) (Author/CLB)
Microgravity cursor control device evaluation for Space Station Freedom workstations
NASA Technical Reports Server (NTRS)
Adam, Susan; Holden, Kritina L.; Gillan, Douglas; Rudisill, Marianne
1991-01-01
This research addressed direct manipulation interface (curser-controlled device) usability in microgravity. The data discussed are from KC-135 flights. This included pointing and dragging movements over a variety of angles and distances. Detailed error and completion time data provided researchers with information regarding cursor control shape, selection button arrangement, sensitivity, selection modes, and considerations for future research.
Collagen-Gold Nanoparticle Conjugates for Versatile Biosensing
Unser, Sarah; Holcomb, Samuel; Cary, ReJeana; Sagle, Laura
2017-01-01
Integration of noble metal nanoparticles with proteins offers promising potential to create a wide variety of biosensors that possess both improved selectivity and versatility. The multitude of functionalities that proteins offer coupled with the unique optical properties of noble metal nanoparticles can allow for the realization of simple, colorimetric sensors for a significantly larger range of targets. Herein, we integrate the structural protein collagen with 10 nm gold nanoparticles to develop a protein-nanoparticle conjugate which possess the functionality of the protein with the desired colorimetric properties of the nanoparticles. Applying the many interactions that collagen undergoes in the extracellular matrix, we are able to selectively detect both glucose and heparin with the same collagen-nanoparticle conjugate. Glucose is directly detected through the cross-linking of the collagen fibrils, which brings the attached nanoparticles into closer proximity, leading to a red-shift in the LSPR frequency. Conversely, heparin is detected through a competition assay in which heparin-gold nanoparticles are added to solution and compete with heparin in the solution for the binding sites on the collagen fibrils. The collagen-nanoparticle conjugates are shown to detect both glucose and heparin in the physiological range. Lastly, glucose is selectively detected in 50% mouse serum with the collagen-nanoparticle devices possessing a linear range of 3–25 mM, which is also within the physiologically relevant range. PMID:28212282
Dairy-cattle health in Gyeongnam, Korea.
Jong, S K; Gong, S K; Chung, H K; Dae, S H
2001-12-03
An animal-health monitoring system in the Gyeongnam area was started in 1997 to develop statistically valid data for use in estimating disease frequencies in dairy cattle, and the associated costs. The objectives of this study were to: (1) describe what was done to implement and maintain the system in Gyeongnam; (2) present selected disease frequencies; (3) discuss the epidemiological consideration of what was done and implications for results obtained. Veterinary medical officers (VMOs), comprising professors and graduate students from Gyeongsang National University, faculty of Gyeongnam Livestock Promotion Institute and clinic veterinarians, served as data collectors. After training on current disease and management problems of dairy cattle, interview techniques, sampling methods and data-collection instruments, the VMOs participated in selection of the sample herds and data gathering. Forty (n=40) of 167 dairy herds were selected randomly using a computer-generated list of random numbers and the VMOs visited farms once in a month for 12 months to collect data about management, disease, inventory, production, preventive treatment, financial and other relevant data. Strict data-quality control devices were used. Specific feed-back was developed for the producers and data collectors. The six disorders found most frequently in cows (from the highest to the lowest) were breeding problems, clinical mastitis, birth problems, gastrointestinal problems, metabolic problems and lameness. In young stock, respiratory, multiple system, breeding and gastrointestinal problems were predominant, whereas in calves, gastrointestinal, respiratory and integumental problems predominated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, D. H.; Das Arulsamy, A.; Rider, A. E.
A simple, effective, and innovative approach based on ion-assisted self-organization is proposed to synthesize size-selected Si quantum dots (QDs) on SiC substrates at low substrate temperatures. Using hybrid numerical simulations, the formation of Si QDs through a self-organization approach is investigated by taking into account two distinct cases of Si QD formation using the ionization energy approximation theory, which considers ionized in-fluxes containing Si{sup 3+} and Si{sup 1+} ions in the presence of a microscopic nonuniform electric field induced by a variable surface bias. The results show that the highest percentage of the surface coverage by 1 and 2 nmmore » size-selected QDs was achieved using a bias of -20 V and ions in the lowest charge state, namely, Si{sup 1+} ions in a low substrate temperature range (227-327 deg. C). As low substrate temperatures ({<=}500 deg. C) are desirable from a technological point of view, because (i) low-temperature deposition techniques are compatible with current thin-film Si-based solar cell fabrication and (ii) high processing temperatures can frequently cause damage to other components in electronic devices and destroy the tandem structure of Si QD-based third-generation solar cells, our results are highly relevant to the development of the third-generation all-Si tandem photovoltaic solar cells.« less
NASA Astrophysics Data System (ADS)
Seo, D. H.; Rider, A. E.; Das Arulsamy, A.; Levchenko, I.; Ostrikov, K.
2010-01-01
A simple, effective, and innovative approach based on ion-assisted self-organization is proposed to synthesize size-selected Si quantum dots (QDs) on SiC substrates at low substrate temperatures. Using hybrid numerical simulations, the formation of Si QDs through a self-organization approach is investigated by taking into account two distinct cases of Si QD formation using the ionization energy approximation theory, which considers ionized in-fluxes containing Si3+ and Si1+ ions in the presence of a microscopic nonuniform electric field induced by a variable surface bias. The results show that the highest percentage of the surface coverage by 1 and 2 nm size-selected QDs was achieved using a bias of -20 V and ions in the lowest charge state, namely, Si1+ ions in a low substrate temperature range (227-327 °C). As low substrate temperatures (≤500 °C) are desirable from a technological point of view, because (i) low-temperature deposition techniques are compatible with current thin-film Si-based solar cell fabrication and (ii) high processing temperatures can frequently cause damage to other components in electronic devices and destroy the tandem structure of Si QD-based third-generation solar cells, our results are highly relevant to the development of the third-generation all-Si tandem photovoltaic solar cells.
B-1 AFT Nacelle Flow Visualization Study
NASA Technical Reports Server (NTRS)
Celniker, Robert
1975-01-01
A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.
Tissue-electronics interfaces: from implantable devices to engineered tissues
NASA Astrophysics Data System (ADS)
Feiner, Ron; Dvir, Tal
2018-01-01
Biomedical electronic devices are interfaced with the human body to extract precise medical data and to interfere with tissue function by providing electrical stimuli. In this Review, we outline physiologically and pathologically relevant tissue properties and processes that are important for designing implantable electronic devices. We summarize design principles for flexible and stretchable electronics that adapt to the mechanics of soft tissues, such as those including conducting polymers, liquid metal alloys, metallic buckling and meandering architectures. We further discuss technologies for inserting devices into the body in a minimally invasive manner and for eliminating them without further intervention. Finally, we introduce the concept of integrating electronic devices with biomaterials and cells, and we envision how such technologies may lead to the development of bionic organs for regenerative medicine.
Chi, Chia-Fen; Tseng, Li-Kai; Jang, Yuh
2012-07-01
Many disabled individuals lack extensive knowledge about assistive technology, which could help them use computers. In 1997, Denis Anson developed a decision tree of 49 evaluative questions designed to evaluate the functional capabilities of the disabled user and choose an appropriate combination of assistive devices, from a selection of 26, that enable the individual to use a computer. In general, occupational therapists guide the disabled users through this process. They often have to go over repetitive questions in order to find an appropriate device. A disabled user may require an alphanumeric entry device, a pointing device, an output device, a performance enhancement device, or some combination of these. Therefore, the current research eliminates redundant questions and divides Anson's decision tree into multiple independent subtrees to meet the actual demand of computer users with disabilities. The modified decision tree was tested by six disabled users to prove it can determine a complete set of assistive devices with a smaller number of evaluative questions. The means to insert new categories of computer-related assistive devices was included to ensure the decision tree can be expanded and updated. The current decision tree can help the disabled users and assistive technology practitioners to find appropriate computer-related assistive devices that meet with clients' individual needs in an efficient manner.
Mohammadi, Mehrnoosh; RezaeiDehaghani, Abdollah; Mehrabi, Tayebeh; RezaeiDehaghani, Ali
2016-01-01
As adolescents spend much time on playing computer games, their mental and social effects should be considered. The present study aimed to investigate the association between playing computer games and the mental and social health among male adolescents in Iran in 2014. This is a cross-sectional study conducted on 210 adolescents selected by multi-stage random sampling. Data were collected by Goldberg and Hillier general health (28 items) and Kiez social health questionnaires. The association was tested by Pearson and Spearman correlation coefficients, one-way analysis of variance (ANOVA), and independent t-test. Computer games related factors such as the location, type, length, the adopted device, and mode of playing games were investigated. Results showed that 58.9% of the subjects played games on a computer alone for 1 h at home. Results also revealed that the subjects had appropriate mental health and 83.2% had moderate social health. Results showed a poor significant association between the length of games and social health (r = -0.15, P = 0.03), the type of games and mental health (r = -0.16, P = 0.01), and the device used in playing games and social health (F = 0.95, P = 0.03). The findings showed that adolescents' mental and social health is negatively associated with their playing computer games. Therefore, to promote their health, educating them about the correct way of playing computer games is essential and their parents and school authorities, including nurses working at schools, should determine its relevant factors such as the type, length, and device used in playing such games.
Characterizing fretting damage in different test media for cardiovascular device durability testing.
Weaver, J D; Ramirez, L; Sivan, S; Di Prima, M
2018-06-01
In vitro durability tests of cardiovascular devices are often used to evaluate the potential for fretting damage during clinical use. Evaluation of fretting damage is important because severe fretting can concentrate stress and lead to the loss of structural integrity. Most international standards call for the use of phosphate buffered saline (PBS) for such tests although there has been little evidence to date that the use of PBS is appropriate in terms of predicting the amount of fretting damage that would occur in vivo. In order to determine an appropriate test media for in vitro durability tests where fretting damage is being evaluated, we utilized an in vitro test that is relevant to cardiovascular devices both in terms of dimensions and materials (nitinol, cobalt-chromium, and stainless steel) to characterize fretting damage in PBS, deionized water (DIW), and heparinized porcine blood. Overall, tests conducted in blood were found to have increased levels of fretting damage over tests in DIW or PBS, although the magnitude of this difference was smaller than the variability for each test media. Tests conducted in DIW and PBS led to mostly similar amounts of fretting damage with the exception of one material combination where DIW had greatly reduced damage compared to PBS and blood. Differences in fretting damage among materials were also observed with nitinol having less fretting damage than stainless steel or cobalt-chromium. In general, evaluating fretting damage in PBS or DIW may be appropriate although caution should be used when selecting test media and interpreting results given some of the differences observed across different materials. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Ji, Hantao; Bhattacharjee, A.; Goodman, A.; Prager, S.; Daughton, W.; Cutler, R.; Fox, W.; Hoffmann, F.; Kalish, M.; Kozub, T.; Jara-Almonte, J.; Myers, C.; Ren, Y.; Sloboda, P.; Yamada, M.; Yoo, J.; Bale, S. D.; Carter, T.; Dorfman, S.; Drake, J.; Egedal, J.; Sarff, J.; Wallace, J.
2017-10-01
The FLARE device (Facility for Laboratory Reconnection Experiments; flare.pppl.gov) is a new laboratory experiment under construction at Princeton for the studies of magnetic reconnection in the multiple X-line regimes directly relevant to space, solar, astrophysical, and fusion plasmas, as guided by a reconnection phase diagram. The whole device have been assembled with first plasmas expected in the fall of 2017. The main diagnostics is an extensive set of magnetic probe arrays, currently under construction, to cover multiple scales from local electron scales ( 2 mm), to intermediate ion scales ( 10 cm), and global MHD scales ( 1 m), simultaneously providing in-situ measurements over all these relevant scales. The planned procedures and example topics as a user facility will be discussed.
A meta-analysis of the effect of media devices on sleep outcomes
Carter, Ben; Rees, Philippa; Hale, Lauren; Bhattacharjee, Darsharna; Paradkar, Mandar
2017-01-01
Importance Sleep is vital to children’s bio-psycho-social development. Inadequate sleep quantity and quality is a public health concern with an array of detrimental health outcomes. Portable mobile and media device have become a ubiquitous part of children’s lives and may impact children’s sleep duration and quality. Objective This systematic review was conducted to examine the effect of portable media devices (e.g. mobile phones, and tablet devices) on sleep outcomes Data Sources A search strategy was developed and searches of the published and grey literature were conducted across 12 databases from January 1st 2011 to June 15th, 2015. No language restriction was applied. Study Selection We included randomized controlled trials; cohort; and cross sectional study designs. Of 467 studies identified, 20 cross-sectional studies were assessed for quality Data Extraction and Synthesis Data extraction and quality assessment was independently carried out by two reviewers and disagreements resolved by a third. Data was pooled in a random-effects meta-analysis, and an individual participant meta-analysis was carried out where possible. Main Outcomes and Measures The primary outcomes were: inadequate sleep quantity; poor sleep quality; and excessive daytime sleepiness, carried out following an a priori protocol. Results Twenty studies were included and quality assessed, involving 125,198 children, 50.1% were male. There was a strong and consistent association between bedtime media device use and: inadequate sleep quantity (OR =2.17; 95%CI 1.42-3.32); poor sleep quality (OR=1.46; 95%CI 1.14-1.88); and excessive daytime sleepiness (OR=2.72; 95%CI 1.32-5.61). Additionally, children who had access to (but did not use) media devices at night were more likely to have inadequate: sleep quantity (OR=1.79; 95%CI 1.39-2.31); sleep quality (OR=1.53; 95%CI 1.11-2.10); and daytime sleepiness (OR=2.27; 95%CI 1.54-3.35). Conclusions and relevance This was the first meta-analysis of the effect of access and use of media device on sleep outcomes. Bedtime access and use of media devices was significantly associated with inadequate sleep quantity; poor sleep quality; and excessive daytime sleepiness. An integrated approach between teachers, healthcare providers and parents is needed to minimize device access at bedtime, and future research is needed to evaluate the impact on sleep hygiene and outcomes. PMID:27802500
EDITORIAL: Design and function of molecular and bioelectronics devices
NASA Astrophysics Data System (ADS)
Krstic, Predrag; Forzani, Erica; Tao, Nongjian; Korkin, Anatoli
2007-10-01
Further rapid progress of electronics, in particular the increase of computer power and breakthroughs in sensor technology for industrial, medical diagnostics and environmental applications, strongly depends on the scaling of electronic devices, ultimately to the size of molecules. Design of controllable molecular-scale devices may resolve the problem of energy dissipation at the nanoscale and take advantage of molecular self-assembly in the so-called bottom-up approach. This special issue of Nanotechnology is devoted to a better understanding of the function and design of molecular-scale devices that are relevant to future electronics and sensor technology. Papers contained in this special issue are selected from the symposium Nano and Giga Challenges in Electronics and Photonics: From Atoms to Materials to Devices to System Architecture (12-16 March, 2007, Phoenix, Arizona, USA), as well as from original and novel scientific contributions of invited world-renown researchers. It addresses both theoretical and experimental achievements in the fields of molecular and bioelectronics, chemical and biosensors at the molecular level, including carbon nanotubes, novel nanostructures, as well as related research areas and industrial applications. The conference series Nano and Giga Challenges in Electronics and Photonics was launched as a truly interdisciplinary forum to bridge scientists and engineers to work across boundaries in the design of future information technologies, from atoms to materials to devices to system architecture. Following the first two successful meetings in Moscow, Russia (NGCM2002) and Krakow, Poland (NGCM2004), the third Nano and Giga Forum (NGC2007) was held in 2007 hosted by Arizona State University. Besides this special issue of Nanotechnology, two other collections (in the journal Solid State Electronics and the tutorial book in the series Nanostructure Science and Technology Springer) have published additional selected and invited papers from NGC2007. The NGC2007 meeting, which included two days of tutorials (Spring School) and a three day symposium, attracted approximately 400 participants from academic, industrial and governmental research institutions from 41 countries, and covered recent developments in the fabrication and functionality of nano-scale materials, devices and system architecture from advanced CMOS to molecular electronics, photonics, optoelectronics and magnetic materials and devices. The success of the conference would not have been possible without generous support from many sponsors and research institutions, especially from Arizona State University (conference host and co-organizer), International Science and Technology Center (ISTC), National Science Foundation (NSFT), Defense Advanced Research Agency (DARPA), Office of Naval Research, Army Research Office, Computational Chemistry List (CCL), Springer Publisher, City of Tempe, STMicroelectronics, Quarles & Brady LLP, Oak Ridge National Laboratory, Canadian Consulate in Phoenix, Salt River Project (SRP) and many other local, national and international and individual supporters. We would like to acknowledge the shared responsibility for this special issue of Nanotechnology on molecular and bioelectronics, and the highly professional support from Dr Nina Couzin, Dr Alex Wotherspoon and the Nanotechnology team from the IOP Publishing. We also acknowledge the exception made in allowing the publication of some material that is outside the normal scope of Nanotechnology.
Design and function of molecular and bioelectronics devices.
Krstic, Predrag; Forzani, Erica; Tao, Nongjian; Korkin, Anatoli
2007-10-24
Further rapid progress of electronics, in particular the increase of computer power and breakthroughs in sensor technology for industrial, medical diagnostics and environmental applications, strongly depends on the scaling of electronic devices, ultimately to the size of molecules. Design of controllable molecular-scale devices may resolve the problem of energy dissipation at the nanoscale and take advantage of molecular self-assembly in the so-called bottom-up approach. This special issue of Nanotechnology is devoted to a better understanding of the function and design of molecular-scale devices that are relevant to future electronics and sensor technology. Papers contained in this special issue are selected from the symposium Nano and Giga Challenges in Electronics and Photonics: From Atoms to Materials to Devices to System Architecture (12-16 March, 2007, Phoenix, Arizona, USA), as well as from original and novel scientific contributions of invited world-renown researchers. It addresses both theoretical and experimental achievements in the fields of molecular and bioelectronics, chemical and biosensors at the molecular level, including carbon nanotubes, novel nanostructures, as well as related research areas and industrial applications. The conference series Nano and Giga Challenges in Electronics and Photonics was launched as a truly interdisciplinary forum to bridge scientists and engineers to work across boundaries in the design of future information technologies, from atoms to materials to devices to system architecture. Following the first two successful meetings in Moscow, Russia (NGCM2002) and Krakow, Poland (NGCM2004), the third Nano and Giga Forum (NGC2007) was held in 2007 hosted by Arizona State University. Besides this special issue of Nanotechnology, two other collections (in the journal Solid State Electronics and the tutorial book in the series Nanostructure Science and Technology Springer) have published additional selected and invited papers from NGC2007. The NGC2007 meeting, which included two days of tutorials (Spring School) and a three day symposium, attracted approximately 400 participants from academic, industrial and governmental research institutions from 41 countries, and covered recent developments in the fabrication and functionality of nano-scale materials, devices and system architecture from advanced CMOS to molecular electronics, photonics, optoelectronics and magnetic materials and devices. The success of the conference would not have been possible without generous support from many sponsors and research institutions, especially from Arizona State University (conference host and co-organizer), International Science and Technology Center (ISTC), National Science Foundation (NSFT), Defense Advanced Research Agency (DARPA), Office of Naval Research, Army Research Office, Computational Chemistry List (CCL), Springer Publisher, City of Tempe, STMicroelectronics, Quarles & Brady LLP, Oak Ridge National Laboratory, Canadian Consulate in Phoenix, Salt River Project (SRP) and many other local, national and international and individual supporters. We would like to acknowledge the shared responsibility for this special issue of Nanotechnology on molecular and bioelectronics, and the highly professional support from Dr Nina Couzin, Dr Alex Wotherspoon and the Nanotechnology team from the IOP Publishing. We also acknowledge the exception made in allowing the publication of some material that is outside the normal scope of Nanotechnology.
Torous, J; Onnela, J-P; Keshavan, M
2017-03-07
Mobile and connected devices like smartphones and wearable sensors can facilitate the collection of novel naturalistic and longitudinal data relevant to psychiatry at both the personal and population level. The National Institute of Mental Health's Research Domain Criteria framework offers a useful roadmap to organize, guide and lead new digital phenotyping data towards research discoveries and clinical advances.
Lipowicz, Michelle; Garcia, Antonio
2015-01-01
The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays. PMID:28955016
Retrieval analysis of motion preserving spinal devices and periprosthetic tissues
Kurtz, Steven M.; Steinbeck, Marla; Ianuzzi, Allyson; van Ooij, André; Punt, Ilona M.; Isaza, Jorge; Ross, E.R.S.
2009-01-01
This article reviews certain practical aspects of retrieval analysis for motion preserving spinal implants and periprosthetic tissues as an essential component of the overall revision strategy for these implants. At our institution, we established an international repository for motion-preserving spine implants in 2004. Our repository is currently open to all spine surgeons, and is intended to be inclusive of all cervical and lumbar implant designs such as artificial discs and posterior dynamic stabilization devices. Although a wide range of alternative materials is being investigated for nonfusion spine implants, many of the examples in this review are drawn from our existing repository of metal-on-polyethylene, metal-on-metal lumbar total disc replacements (TDRs), and polyurethane-based dynamic motion preservation devices. These devices are already approved or nearing approval for use in the United States, and hence are the most clinically relevant at the present time. This article summarizes the current literature on the retrieval analysis of these implants and concludes with recommendations for the development of new test methods that are based on the current state of knowledge of in vivo wear and damage mechanisms. Furthermore, the relevance and need to evaluate the surrounding tissue to obtain a complete understanding of the biological reaction to implant component corrosion and wear is reviewed. PMID:25802641
Initial Development of an E-cigarette Purchase Task: A Mixed Methods Study
Cassidy, Rachel N.; Tidey, Jennifer W.; Colby, Suzanne M.; Long, Victoria; Higgins, Stephen T.
2017-01-01
Objectives Behavioral economic purchase tasks, which estimate demand for drugs, have been successfully developed for cigarettes and are widely used. However, a validated purchase task does not yet exist for e-cigarettes. The aim of this project was to identify the relevant units for an e-cigarette purchase task (E-CPT). Methods Focus groups (N=28 participants in 7 groups, 2-7 participants per group) consisting of current e-cigarette users were conducted. Participants discussed their daily use patterns, completed a preliminary E-CPT which asked how many puffs of their e-cigarette they would consume per day at escalating prices, and discussed the extent to which the task accurately reflected their real-world behavior. Groups were recorded and transcribed; analysis focused on statements related to daily consumption and the E-CPT. Results Participants were unlikely to quantify their daily use in terms of puffs, and perceptions about the appropriate unit for an E-CPT varied across device type. Users of first-generation devices (eg, cigalikes) reported that the relevant unit was the individual device/cartridge; however, participants who purchased nicotine liquid for their device emphasized that e-liquid volume in milliliters would better reflect their use. Conclusions Multiple versions of the E-CPT may be necessary to provide valid measures of e-cigarette demand. PMID:28824938
Monte Carlo simulation of ion-material interactions in nuclear fusion devices
NASA Astrophysics Data System (ADS)
Nieto Perez, M.; Avalos-Zuñiga, R.; Ramos, G.
2017-06-01
One of the key aspects regarding the technological development of nuclear fusion reactors is the understanding of the interaction between high-energy ions coming from the confined plasma and the materials that the plasma-facing components are made of. Among the multiple issues important to plasma-wall interactions in fusion devices, physical erosion and composition changes induced by energetic particle bombardment are considered critical due to possible material flaking, changes to surface roughness, impurity transport and the alteration of physicochemical properties of the near surface region due to phenomena such as redeposition or implantation. A Monte Carlo code named MATILDA (Modeling of Atomic Transport in Layered Dynamic Arrays) has been developed over the years to study phenomena related to ion beam bombardment such as erosion rate, composition changes, interphase mixing and material redeposition, which are relevant issues to plasma-aided manufacturing of microelectronics, components on object exposed to intense solar wind, fusion reactor technology and other important industrial fields. In the present work, the code is applied to study three cases of plasma material interactions relevant to fusion devices in order to highlight the code's capabilities: (1) the Be redeposition process on the ITER divertor, (2) physical erosion enhancement in castellated surfaces and (3) damage to multilayer mirrors used on EUV diagnostics in fusion devices due to particle bombardment.
Oehl, M; Sutter, C
2015-05-01
With aging visual feedback becomes increasingly relevant in action control. Consequently, visual device and task characteristics should more and more affect tool use. Focussing on late working age, the present study aims to investigate age-related differences in processing task irrelevant (display size) and task relevant visual information (task difficulty). Young and middle-aged participants (20-35 and 36-64 years of age, respectively) sat in front of a touch screen with differently sized active touch areas (4″ to 12″) and performed pointing tasks with differing task difficulties (1.8-5 bits). Both display size and age affected pointing performance, but the two variables did not interact and aiming duration moderated both effects. Furthermore, task difficulty affected the pointing durations of middle-aged adults moreso than those of young adults. Again, aiming duration accounted for the variance in the data. The onset of an age-related decline in aiming duration can be clearly located in middle adulthood. Thus, the fine psychomotor ability "aiming" is a moderator and predictor for age-related differences in pointing tasks. The results support a user-specific design for small technical devices with touch interfaces. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Blackburn, Bryan M; Wachsman, Eric D
2015-05-12
Embodiments of the subject invention relate to a gas sensor and method for sensing one or more gases. An embodiment incorporates an array of sensing electrodes maintained at similar or different temperatures, such that the sensitivity and species selectivity of the device can be fine tuned between different pairs of sensing electrodes. A specific embodiment pertains to a gas sensor array for monitoring combustion exhausts and/or chemical reaction byproducts. An embodiment of the subject device related to this invention operates at high temperatures and can withstand harsh chemical environments. Embodiments of the device are made on a single substrate. The devices can also be made on individual substrates and monitored individually as if they were part of an array on a single substrate. The device can incorporate sensing electrodes in the same environment, which allows the electrodes to be coplanar and, thus, keep manufacturing costs low. Embodiments of the device can provide improvements to sensitivity, selectivity, and signal interference via surface temperature control.
Interdependent networks: the fragility of control
Morris, Richard G.; Barthelemy, Marc
2013-01-01
Recent work in the area of interdependent networks has focused on interactions between two systems of the same type. However, an important and ubiquitous class of systems are those involving monitoring and control, an example of interdependence between processes that are very different. In this Article, we introduce a framework for modelling ‘distributed supervisory control' in the guise of an electrical network supervised by a distributed system of control devices. The system is characterised by degrees of freedom salient to real-world systems— namely, the number of control devices, their inherent reliability, and the topology of the control network. Surprisingly, the behavior of the system depends crucially on the reliability of control devices. When devices are completely reliable, cascade sizes are percolation controlled; the number of devices being the relevant parameter. For unreliable devices, the topology of the control network is important and can dramatically reduce the resilience of the system. PMID:24067404
Simulation of drive of mechanisms, working in specific conditions
NASA Astrophysics Data System (ADS)
Ivanovskaya, A. V.; Rybak, A. T.
2018-05-01
This paper presents a method for determining the dynamic loads on the lifting actuator device other than the conventional methods, for example, ship windlass. For such devices, the operation of their drives is typical under special conditions: different environments, the influence of hydrometeorological factors, a high level of vibration, variability of loading, etc. Hoisting devices working in such conditions are not considered in the standard; however, relevant studies concern permissible parameters of the drive devices of this kind. As an example, the article studied the work deck lifting devices - windlass. To construct a model, the windlass is represented by a rod of the variable cross-section. As a result, a mathematical model of the longitudinal oscillations of such rod is obtained. Analytic dependencies have also been obtained to determine the natural frequencies of the lowest forms of oscillations, which are necessary and are the basis for evaluating the parameters of operation of this type of the device.
Jacobs, Esther; Antoine, Sunya-Lee; Prediger, Barbara; Neugebauer, Edmund; Eikermann, Michaela
2017-01-01
Defining relevant outcome measures for clinical trials on medical devices (MD) is complex, as there is a large variety of potentially relevant outcomes. The chosen outcomes vary widely across clinical trials making the assessment in evidence syntheses very challenging. The objective is to provide an overview on the current common procedures of health technology assessment (HTA) institutions in defining outcome measures in MD trials. In 2012-14, the Web pages of 126 institutions involved in HTA were searched for methodological manuals written in English or German that describe methods for the predefinition process of outcome measures. Additionally, the institutions were contacted by email. Relevant information was extracted. All process steps were performed independently by two reviewers. Twenty-four manuals and ten responses from the email request were included in the analysis. Overall, 88.5 percent of the institutions describe the type of outcomes that should be considered in detail and 84.6 percent agree that the main focus should be on patient relevant outcomes. Specifically related to MD, information could be obtained in 26 percent of the included manuals and email responses. Eleven percent of the institutions report a particular consideration of MD related outcomes. This detailed analysis on common procedures of HTA institutions in the context of defining relevant outcome measures for the assessment of MD shows that standardized procedures for MD from the perspective of HTA institutions are not widespread. This leads to the question if a homogenous approach should be implemented in the field of HTA on MD.
Method of examining microcircuit patterns
NASA Technical Reports Server (NTRS)
Suszko, S. F. (Inventor)
1986-01-01
Examination of microstructures of LSI and VLSI devices is facilitated by employing a method in which the device is photographed through a darkfield illumination optical microscope and the resulting negative subjected to inverse processing to form a positive on a photographic film. The film is then developed to form photographic prints or transparencies which clearly illustrate the structure of the device. The entire structure of a device may be examined by alternately photographing the device and selectively etching layers of the device in order to expose underlying layers.
Continuous flow nitration in miniaturized devices
2014-01-01
Summary This review highlights the state of the art in the field of continuous flow nitration with miniaturized devices. Although nitration has been one of the oldest and most important unit reactions, the advent of miniaturized devices has paved the way for new opportunities to reconsider the conventional approach for exothermic and selectivity sensitive nitration reactions. Four different approaches to flow nitration with microreactors are presented herein and discussed in view of their advantages, limitations and applicability of the information towards scale-up. Selected recent patents that disclose scale-up methodologies for continuous flow nitration are also briefly reviewed. PMID:24605161
Tsuo, Y.S.; Deb, S.K.
1990-10-02
Disclosed is a hydrogen ion microlithography process for use in microelectronic fabrication and semiconductor device processing. The process comprises the steps of providing a single layer of either an amorphous silicon or hydrogenated amorphous silicon material. A pattern is recorded in a selected layer of amorphous silicon or hydrogenated amorphous silicon materials by preferentially implanting hydrogen ions therein so as to permit the selected layer to serve as a mask-resist wafer suitable for subsequent development and device fabrication. The layer is developed to provide a surface pattern therein adaptable for subsequent use in microelectronic fabrication and semiconductor device processing. 6 figs.
Combustion driven ammonia generation strategies for passive ammonia SCR system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toner, Joel G.; Narayanaswamy, Kushal; Szekely, Jr., Gerald A.
A method for controlling ammonia generation in an exhaust gas feedstream output from an internal combustion engine equipped with an exhaust aftertreatment system including a first aftertreatment device includes executing an ammonia generation cycle to generate ammonia on the first aftertreatment device. A desired air-fuel ratio output from the engine and entering the exhaust aftertreatment system conducive for generating ammonia on the first aftertreatment device is determined. Operation of a selected combination of a plurality of cylinders of the engine is selectively altered to achieve the desired air-fuel ratio entering the exhaust aftertreatment system.
The Construct of Attention in Schizophrenia
Luck, Steven J.; Gold, James M.
2008-01-01
Schizophrenia is widely thought to involve deficits of attention. However, the term attention can be defined so broadly that impaired performance on virtually any task could be construed as evidence for a deficit in attention, and this has slowed cumulative progress in understanding attention deficits in schizophrenia. To address this problem, we divide the general concept of attention into two distinct constructs: input selection, the selection of task-relevant inputs for further processing; and rule selection, the selective activation of task-appropriate rules. These constructs are closely tied to working memory, because input selection mechanisms are used to control the transfer of information into working memory and because working memory stores the rules used by rule selection mechanisms. These constructs are also closely tied to executive function, because executive systems are used to guide input selection and because rule selection is itself at key aspect of executive function. Within the domain of input selection, it is important to distinguish between the control of selection—the processes that guide attention to task-relevant inputs—and the implementation of selection—the processes that enhance the processing of the relevant inputs and suppress the irrelevant inputs. Current evidence suggests that schizophrenia involves a significant impairment in the control of selection but little or no impairment in the implementation of selection. Consequently, the CNTRICS participants agreed by consensus that attentional control should be a priority target for measurement and treatment research in schizophrenia. PMID:18374901
Two multichannel integrated circuits for neural recording and signal processing.
Obeid, Iyad; Morizio, James C; Moxon, Karen A; Nicolelis, Miguel A L; Wolf, Patrick D
2003-02-01
We have developed, manufactured, and tested two analog CMOS integrated circuit "neurochips" for recording from arrays of densely packed neural electrodes. Device A is a 16-channel buffer consisting of parallel noninverting amplifiers with a gain of 2 V/V. Device B is a 16-channel two-stage analog signal processor with differential amplification and high-pass filtering. It features selectable gains of 250 and 500 V/V as well as reference channel selection. The resulting amplifiers on Device A had a mean gain of 1.99 V/V with an equivalent input noise of 10 microV(rms). Those on Device B had mean gains of 53.4 and 47.4 dB with a high-pass filter pole at 211 Hz and an equivalent input noise of 4.4 microV(rms). Both devices were tested in vivo with electrode arrays implanted in the somatosensory cortex.
Radiation analysis devices, radiation analysis methods, and articles of manufacture
Roybal, Lyle Gene
2010-06-08
Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.
NASA Astrophysics Data System (ADS)
Son, Seok Young; Lee, Hyomin; Kim, Sung Jae
2017-12-01
Recently, novel biomolecules separation and detection methods based on ion concentration polarization (ICP) phenomena have been extensively researched due to its high amplification ratio and high-speed accumulation. Despite of these bright advances, the fabrication of conventional ICP devices still have complicated and times-consuming tasks. As an alternative platform, a paper have been recently used for the identical ICP operations. In this work, we demonstrated the selective preconcentration of a muc1 gene fragment as human breast cancer marker and a lamp-2 gene fragment as the cause of Danon disease in paper-based ICP devices. As a result, these two DNA fragments were successfully concentrated up to 60 fold at different location in a single paper-channel. The device would be a promising platform for point-of-care device due to an economic fabrication, the easy extraction of concentrated sample and an easy disposability.
Kumsa, Doe; Steinke, G. Karl; Molnar, Gregory F.; Hudak, Eric M.; Montague, Fred W.; Kelley, Shawn C.; Untereker, Darrel F.; Shi, Alan; Hahn, Benjamin P.; Condit, Chris; Lee, Hyowon; Bardot, Dawn; Centeno, Jose A.; Krauthamer, Victor; Takmakov, Pavel A.
2017-01-01
Objective The Shannon model is often used to define an expected boundary between non-damaging and damaging modes of electrical neurostimulation. Numerous preclinical studies have been performed by manufacturers of neuromodulation devices using different animal models and a broad range of stimulation parameters while developing devices for clinical use. These studies are mostly absent from peer-reviewed literature, which may lead to this information being overlooked by the scientific community. We aimed to locate summaries of these studies accessible via public regulatory databases and to add them to a body of knowledge available to a broad scientific community. Methods We employed web search terms describing device type, intended use, neural target, therapeutic application, company name, and submission number to identify summaries for premarket approval (PMA) devices and 510(k) devices. We filtered these records to a subset of entries that have sufficient technical information relevant to safety of neurostimulation. Results We identified 13 product codes for 8 types of neuromodulation devices. These led us to devices that have 22 PMAs and 154 510(k)s and six transcripts of public panel meetings. We found one PMA for a brain, peripheral nerve, and spinal cord stimulator and five 510(k) spinal cord stimulators with enough information to plot in Shannon coordinates of charge and charge density per phase. Conclusions Analysis of relevant entries from public regulatory databases reveals use of pig, sheep, monkey, dog, and goat animal models with deep brain, peripheral nerve, muscle and spinal cord electrode placement with a variety of stimulation durations (hours to years); frequencies (10–10,000 Hz) and magnitudes (Shannon k from below zero to 4.47). Data from located entries indicate that a feline cortical model that employs acute stimulation might have limitations for assessing tissue damage in diverse anatomical locations, particularly for peripheral nerve and spinal cord simulation. PMID:28782181
Kumsa, Doe; Steinke, G Karl; Molnar, Gregory F; Hudak, Eric M; Montague, Fred W; Kelley, Shawn C; Untereker, Darrel F; Shi, Alan; Hahn, Benjamin P; Condit, Chris; Lee, Hyowon; Bardot, Dawn; Centeno, Jose A; Krauthamer, Victor; Takmakov, Pavel A
2018-02-01
The Shannon model is often used to define an expected boundary between non-damaging and damaging modes of electrical neurostimulation. Numerous preclinical studies have been performed by manufacturers of neuromodulation devices using different animal models and a broad range of stimulation parameters while developing devices for clinical use. These studies are mostly absent from peer-reviewed literature, which may lead to this information being overlooked by the scientific community. We aimed to locate summaries of these studies accessible via public regulatory databases and to add them to a body of knowledge available to a broad scientific community. We employed web search terms describing device type, intended use, neural target, therapeutic application, company name, and submission number to identify summaries for premarket approval (PMA) devices and 510(k) devices. We filtered these records to a subset of entries that have sufficient technical information relevant to safety of neurostimulation. We identified 13 product codes for 8 types of neuromodulation devices. These led us to devices that have 22 PMAs and 154 510(k)s and six transcripts of public panel meetings. We found one PMA for a brain, peripheral nerve, and spinal cord stimulator and five 510(k) spinal cord stimulators with enough information to plot in Shannon coordinates of charge and charge density per phase. Analysis of relevant entries from public regulatory databases reveals use of pig, sheep, monkey, dog, and goat animal models with deep brain, peripheral nerve, muscle and spinal cord electrode placement with a variety of stimulation durations (hours to years); frequencies (10-10,000 Hz) and magnitudes (Shannon k from below zero to 4.47). Data from located entries indicate that a feline cortical model that employs acute stimulation might have limitations for assessing tissue damage in diverse anatomical locations, particularly for peripheral nerve and spinal cord simulation. © 2017 International Neuromodulation Society.
Side effects of intraoral devices for OSAS treatment.
Teixeira, Andressa Otranto de Britto; Andrade, Ana Luiza Ladeia; Almeida, Rhita Cristina da Cunha; Almeida, Marco Antonio de Oliveira
2017-10-14
Intraoral devices have increasingly assumed a key role in the treatment of obstructive sleep apnea syndrome, but there are limitations to their indication and side effects that result from their continuous use, as well as the use of the continuous positive airway pressure device. To evaluate the changes in dental positioning caused by the continuous use of mandibular advancement devices. A prospective longitudinal study with a sample of 15 patients, with evaluation of complete documentation after a mean time of 6.47 months, assessed changes in dental positioning due to the use of the Twin Block oral device for the treatment of patients with apnea. The following variables were evaluated: overjet, overbite, upper and lower intermolar distances, upper and lower intercanine distances, Little's irregularity index and the incisor mandibular plane angle. An intraclass correlation test was performed and a correlation index>0.08 was accepted. After verifying the normal sample distribution (Shapiro-Wilks), a parametric test was used (t test), with a significance level set at 5%. There was a decrease in the values of overjet, overbite and Little's irregularity index, whereas there was an increase in the lower intercanine distance and IMPA values. All these variables are influenced, at different levels, by the forward inclination of the lower incisors, an action that can be expected due to the force applied by the device on the dentition. The other variables did not show statistically significant differences. After a mean time of 6.47 months of use of the mandibular advancement device, there were statistically significant changes in the dental positioning, but they were not clinically relevant. However, it is relevant that this device is commonly in use over long periods of time, making the monitoring of these patients of the utmost importance for the duration of their therapy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Hardy's test as a device-independent dimension witness
NASA Astrophysics Data System (ADS)
Mukherjee, Amit; Roy, Arup; Bhattacharya, Some Sankar; Das, Subhadipa; Gazi, Md. Rajjak; Banik, Manik
2015-08-01
Knowing the dimension of an unknown physical system has practical relevance, as dimensionality plays an important role in various information theoretic tasks. In this work we show that a modified version of Hardy's argument, which reveals the contradiction of quantum theory with local realism, turns out to be useful for inspecting the minimal subsystem dimension of an unknown correlated quantum system. The use of Hardy's test in this task has a novel advantage: the subsystem dimension can be determined without knowing the detailed functioning of the experimental devices; i.e., Hardy's test suffices to be a device-independent dimension witness.
ERIC Educational Resources Information Center
Gajek, Elzbieta
2016-01-01
This paper presents the use of mobile devices by students of linguistics, future foreign language teachers, outside the university and in-campus, and their vision of the potential usefulness of such devices for language learning at tertiary level. As various characteristics of mobile devices influence their usability, users select a device to fit…
Multiple-input multiple-output causal strategies for gene selection.
Bontempi, Gianluca; Haibe-Kains, Benjamin; Desmedt, Christine; Sotiriou, Christos; Quackenbush, John
2011-11-25
Traditional strategies for selecting variables in high dimensional classification problems aim to find sets of maximally relevant variables able to explain the target variations. If these techniques may be effective in generalization accuracy they often do not reveal direct causes. The latter is essentially related to the fact that high correlation (or relevance) does not imply causation. In this study, we show how to efficiently incorporate causal information into gene selection by moving from a single-input single-output to a multiple-input multiple-output setting. We show in synthetic case study that a better prioritization of causal variables can be obtained by considering a relevance score which incorporates a causal term. In addition we show, in a meta-analysis study of six publicly available breast cancer microarray datasets, that the improvement occurs also in terms of accuracy. The biological interpretation of the results confirms the potential of a causal approach to gene selection. Integrating causal information into gene selection algorithms is effective both in terms of prediction accuracy and biological interpretation.
Local Jurisdictions and Active Shooters: Building Networks, Building Capacities
2010-12-01
coordination will be the foundation for identifying relevant sources and materials on the armed active shooter assault. This research will also benefit...CONCLUSION In summary, the literature review identified relevant sources and materials on the importance of an armed attack. While an armed assault...armed with the following: dozens of explosive devices of varying potency, seven knives, two Savage-Stevens 12 gauge double- barrel shotguns with the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, Richard; Branch, Darren; Edwards, Thayne
The acoustic wave biosensor is innovative device that is a handheld, battery-powered, portable detection system capable of multiplex identification of a wide range of medically relevant pathogens and their biomolecular signatures — viruses, bacteria, proteins, and DNA — at clinically relevant levels. This detection occurs within minutes — not hours — at the point of care, whether that care is in a physician's office, a hospital bed, or at the scene of a biodefense or biomedical emergency.
Cell-phone-based platform for biomedical device development and education applications.
Smith, Zachary J; Chu, Kaiqin; Espenson, Alyssa R; Rahimzadeh, Mehdi; Gryshuk, Amy; Molinaro, Marco; Dwyre, Denis M; Lane, Stephen; Matthews, Dennis; Wachsmann-Hogiu, Sebastian
2011-03-02
In this paper we report the development of two attachments to a commercial cell phone that transform the phone's integrated lens and image sensor into a 350x microscope and visible-light spectrometer. The microscope is capable of transmission and polarized microscopy modes and is shown to have 1.5 micron resolution and a usable field-of-view of 150 x 50 with no image processing, and approximately 350 x 350 when post-processing is applied. The spectrometer has a 300 nm bandwidth with a limiting spectral resolution of close to 5 nm. We show applications of the devices to medically relevant problems. In the case of the microscope, we image both stained and unstained blood-smears showing the ability to acquire images of similar quality to commercial microscope platforms, thus allowing diagnosis of clinical pathologies. With the spectrometer we demonstrate acquisition of a white-light transmission spectrum through diffuse tissue as well as the acquisition of a fluorescence spectrum. We also envision the devices to have immediate relevance in the educational field.
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Zachary J.; Chu, Kaiqin; Espenson, Alyssa R.; Rahimzadeh, Mehdi; Gryshuk, Amy; Molinaro, Marco; Dwyre, Denis M.; Lane, Stephen; Matthews, Dennis; Wachsmann-Hogiu, Sebastian
2011-01-01
In this paper we report the development of two attachments to a commercial cell phone that transform the phone's integrated lens and image sensor into a 350× microscope and visible-light spectrometer. The microscope is capable of transmission and polarized microscopy modes and is shown to have 1.5 micron resolution and a usable field-of-view of 150×150 with no image processing, and approximately 350×350 when post-processing is applied. The spectrometer has a 300 nm bandwidth with a limiting spectral resolution of close to 5 nm. We show applications of the devices to medically relevant problems. In the case of the microscope, we image both stained and unstained blood-smears showing the ability to acquire images of similar quality to commercial microscope platforms, thus allowing diagnosis of clinical pathologies. With the spectrometer we demonstrate acquisition of a white-light transmission spectrum through diffuse tissue as well as the acquisition of a fluorescence spectrum. We also envision the devices to have immediate relevance in the educational field. PMID:21399693
Portable receiver for radar detection
Lopes, Christopher D.; Kotter, Dale K.
2008-10-14
Various embodiments are described relating to a portable antenna-equipped device for multi-band radar detection. The detection device includes a plurality of antennas on a flexible substrate, a detection-and-control circuit, an indicator and a power source. The antenna may include one or more planar lithographic antennas that may be fabricated on a thin-film substrate. Each antenna may be tuned to a different selection frequency or band. The antennas may include a bolometer for radar detection. Each antenna may include a frequency selective surface for tuning to the selection frequency.
Torstrick, F Brennan; Klosterhoff, Brett S; Westerlund, L Erik; Foley, Kevin T; Gochuico, Joanna; Lee, Christopher S D; Gall, Ken; Safranski, David L
2018-05-01
Various surface modifications, often incorporating roughened or porous surfaces, have recently been introduced to enhance osseointegration of interbody fusion devices. However, these topographical features can be vulnerable to damage during clinical impaction. Despite the potential negative impact of surface damage on clinical outcomes, current testing standards do not replicate clinically relevant impaction loading conditions. The purpose of this study was to compare the impaction durability of conventional smooth polyether-ether-ketone (PEEK) cervical interbody fusion devices with two surface-modified PEEK devices that feature either a porous structure or plasma-sprayed titanium coating. A recently developed biomechanical test method was adapted to simulate clinically relevant impaction loading conditions during cervical interbody fusion procedures. Three cervical interbody fusion devices were used in this study: smooth PEEK, plasma-sprayed titanium-coated PEEK, and porous PEEK (n=6). Following Kienle et al., devices were impacted between two polyurethane blocks mimicking vertebral bodies under a constant 200 N preload. The posterior tip of the device was placed at the entrance between the polyurethane blocks, and a guided 1-lb weight was impacted upon the anterior face with a maximum speed of 2.6 m/s to represent the strike force of a surgical mallet. Impacts were repeated until the device was fully impacted. Porous PEEK durability was assessed using micro-computed tomography (µCT) pre- and postimpaction. Titanium-coating coverage pre- and postimpaction was assessed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. Changes to the surface roughness of smooth and titanium-coated devices were also evaluated. Porous PEEK and smooth PEEK devices showed minimal macroscopic signs of surface damage, whereas the titanium-coated devices exhibited substantial visible coating loss. Quantification of the porous PEEK deformation demonstrated that the porous structure maintained a high porosity (>65%) following impaction that would be available for bone ingrowth, and exhibited minimal changes to pore size and depth. SEM and energy dispersive X-ray spectroscopy analysis of titanium-coated devices demonstrated substantial titanium coating loss after impaction that was corroborated with a decrease in surface roughness. Smooth PEEK showed minimal signs of damage using SEM, but demonstrated a decrease in surface roughness. Although recent surface modifications to interbody fusion devices are beneficial for osseointegration, they may be susceptible to damage and wear during impaction. The current study found porous PEEK devices to show minimal damage during simulated cervical impaction, whereas titanium-coated PEEK devices lost substantial titanium coverage. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.
Kim, Yong-Kwan; Kang, Pil Soo; Kim, Dae-Il; Shin, Gunchul; Kim, Gyu Tae; Ha, Jeong Sook
2009-03-01
A printing-based lithographic technique for the patterning of V(2)O(5) nanowire channels with unidirectional orientation and controlled length is introduced. The simple, directional blowing of a patterned polymer stamp with N(2) gas, inked with randomly distributed V(2)O(5) nanowires, induces alignment of the nanowires perpendicular to the long axis of the line patterns. Subsequent stamping on the amine-terminated surface results in the selective transfer of the aligned nanowires with a controlled length corresponding to the width of the relief region of the polymer stamp. By employing such a gas-blowing-assisted, selective-transfer-printing technique, two kinds of device structures consisting of nanowire channels and two metal electrodes with top contact, whereby the nanowires were aligned either parallel (parallel device) or perpendicular (serial device) to the current flow in the conduction channel, are fabricated. The electrical properties demonstrate a noticeable difference between the two devices, with a large hysteresis in the parallel device but none in the serial device. Systematic analysis of the hysteresis and the electrical stability account for the observed hysteresis in terms of the proton diffusion in the water layer of the V(2)O(5) nanowires, induced by the application of an external bias voltage higher than a certain threshold voltage.
Survey Finds Few Orthopedic Surgeons Know The Costs Of The Devices They Implant
Okike, Kanu; O’Toole, Robert V.; Pollak, Andrew N.; Bishop, Julius A.; McAndrew, Christopher M.; Mehta, Samir; Cross, William W.; Garrigues, Grant E.; Harris, Mitchel B.; Lebrun, Christopher T.
2014-01-01
Orthopedic procedures represent a large expense to the Medicare program, and costs of implantable medical devices account for a large proportion of those procedures’ costs. Physicians have been encouraged to consider costs in the selection of devices, but several factors make acquiring information about costs difficult. To assess physicians’ levels of knowledge about costs, we asked orthopedic attending physicians and residents at seven academic medical centers to estimate the costs of thirteen commonly used orthopedic devices between December 2012 and March 2013. The actual cost of each device was determined at each institution; estimates within 20 percent of the actual cost were considered correct. Among the 503 physicians who completed our survey, attending physicians correctly estimated the cost of the device 21 percent of the time, and residents did so 17 percent of the time. Thirty-six percent of physicians and 75 percent of residents rated their knowledge of device costs “below average” or “poor.” However, more than 80 percent of all respondents indicated that cost should be “moderately,” “very,” or “extremely” important in the device selection process. Surgeons need increased access to information on the relative prices of devices and should be incentivized to participate in cost-containment efforts. PMID:24395941
Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J
2006-04-01
Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.
Paper-based CRP Monitoring Devices
NASA Astrophysics Data System (ADS)
Lin, Shang-Chi; Tseng, Chung-Yuh; Lai, Po-Liang; Hsu, Min-Yen; Chu, Shueh-Yao; Tseng, Fan-Gang; Cheng, Chao-Min
2016-12-01
Here, we discuss the development of a paper-based diagnostic device that is inexpensive, portable, easy-to-use, robust, and capable of running simultaneous tests to monitor a relevant inflammatory protein for clinical diagnoses i.e. C-reactive protein (CRP). In this study, we first attempted to make a paper-based diagnostic device via the wax printing method, a process that was used in previous studies. This device has two distinct advantages: 1) reduced manufacturing and assay costs and operation duration via using wax printing method to define hydrophobic boundaries (for fluidic devices or general POC devices); and, 2) the hydrophilicity of filter paper, which is used to purify and chromatographically correct interference caused by whole blood components with a tiny amount of blood sample (only 5 μL). Diagnosis was based on serum stain length retained inside the paper channels of our device. This is a balanced function between surface tension and chromatographic force following immune reactions (CRP assays) with a paper-embedded biomarker.
Andersen, Pia; Lindgaard, Anne-Mette; Prgomet, Mirela; Creswick, Nerida; Westbrook, Johanna I
2009-08-04
Selecting the right mix of stationary and mobile computing devices is a significant challenge for system planners and implementers. There is very limited research evidence upon which to base such decisions. We aimed to investigate the relationships between clinician role, clinical task, and selection of a computer hardware device in hospital wards. Twenty-seven nurses and eight doctors were observed for a total of 80 hours as they used a range of computing devices to access a computerized provider order entry system on two wards at a major Sydney teaching hospital. Observers used a checklist to record the clinical tasks completed, devices used, and location of the activities. Field notes were also documented during observations. Semi-structured interviews were conducted after observation sessions. Assessment of the physical attributes of three devices-stationary PCs, computers on wheels (COWs) and tablet PCs-was made. Two types of COWs were available on the wards: generic COWs (laptops mounted on trolleys) and ergonomic COWs (an integrated computer and cart device). Heuristic evaluation of the user interfaces was also carried out. The majority (93.1%) of observed nursing tasks were conducted using generic COWs. Most nursing tasks were performed in patients' rooms (57%) or in the corridors (36%), with a small percentage at a patient's bedside (5%). Most nursing tasks related to the preparation and administration of drugs. Doctors on ward rounds conducted 57.3% of observed clinical tasks on generic COWs and 35.9% on tablet PCs. On rounds, 56% of doctors' tasks were performed in the corridors, 29% in patients' rooms, and 3% at the bedside. Doctors not on a ward round conducted 93.6% of tasks using stationary PCs, most often within the doctors' office. Nurses and doctors were observed performing workarounds, such as transcribing medication orders from the computer to paper. The choice of device was related to clinical role, nature of the clinical task, degree of mobility required, including where task completion occurs, and device design. Nurses' work, and clinical tasks performed by doctors during ward rounds, require highly mobile computer devices. Nurses and doctors on ward rounds showed a strong preference for generic COWs over all other devices. Tablet PCs were selected by doctors for only a small proportion of clinical tasks. Even when using mobile devices clinicians completed a very low proportion of observed tasks at the bedside. The design of the devices and ward space configurations place limitations on how and where devices are used and on the mobility of clinical work. In such circumstances, clinicians will initiate workarounds to compensate. In selecting hardware devices, consideration should be given to who will be using the devices, the nature of their work, and the physical layout of the ward.
Klaver, Peter; Talsma, Durk
2013-11-01
We recorded ERPs to investigate whether the visual memory load can bias visual selective attention. Participants memorized one or four letters and then responded to memory-matching letters presented in a relevant color while ignoring distractor letters or letters in an irrelevant color. Stimuli in the relevant color elicited larger frontal selection positivities (FSP) and occipital selection negativities (OSN) compared to irrelevant color stimuli. Only distractors elicited a larger FSP in the high than in the low memory load task. Memory load prolonged the OSN for all letters. Response mapping complexity was also modulated but did not affect the FSP and OSN. Together, the FSP data suggest that high memory load increased distractability. The OSN data suggest that memory load sustained attention to letters in a relevant color until working memory processing was completed, independently of whether the letters were in working memory or not. Copyright © 2013 Society for Psychophysiological Research.
ERIC Educational Resources Information Center
Rouet, Jean-Francois; Ros, Christine; Goumi, Antonine; Macedo-Rouet, Monica; Dinet, Jerome
2011-01-01
Two experiments investigated primary and secondary school students' Web menu selection strategies using simulated Web search tasks. It was hypothesized that students' selections of websites depend on their perception and integration of multiple relevance cues. More specifically, students should be able to disentangle superficial cues (e.g.,…
Pullagurla, Swathi R; Witek, Małgorzata A; Jackson, Joshua M; Lindell, Maria A M; Hupert, Mateusz L; Nesterova, Irina V; Baird, Alison E; Soper, Steven A
2014-04-15
We report the design and performance of a polymer microfluidic device that can affinity select multiple types of biological cells simultaneously with sufficient recovery and purity to allow for the expression profiling of mRNA isolated from these cells. The microfluidic device consisted of four independent selection beds with curvilinear channels that were 25 μm wide and 80 μm deep and were modified with antibodies targeting antigens specifically expressed by two different cell types. Bifurcated and Z-configured device geometries were evaluated for cell selection. As an example of the performance of these devices, CD4+ T-cells and neutrophils were selected from whole blood as these cells are known to express genes found in stroke-related expression profiles that can be used for the diagnosis of this disease. CD4+ T-cells and neutrophils were simultaneously isolated with purities >90% using affinity-based capture in cyclic olefin copolymer (COC) devices with a processing time of ∼3 min. In addition, sufficient quantities of the cells could be recovered from a 50 μL whole blood input to allow for reverse transcription-polymerase chain reaction (RT-PCR) following cell lysis. The expression of genes from isolated T-cells and neutrophils, such as S100A9, TCRB, and FPR1, was evaluated using RT-PCR. The modification and isolation procedures demonstrated here can also be used to analyze other cell types as well where multiple subsets must be interrogated.
40 CFR 610.17 - Application format.
Code of Federal Regulations, 2010 CFR
2010-07-01
... application format, in order to allow the Administrator to compile relevant data on specific devices and to... be allowed for analysis of the application and preparation of a response. As indicated in other...
40 CFR 610.17 - Application format.
Code of Federal Regulations, 2011 CFR
2011-07-01
... application format, in order to allow the Administrator to compile relevant data on specific devices and to... be allowed for analysis of the application and preparation of a response. As indicated in other...
A passive cold storage device economic model to evaluate selected immunization location scenarios.
Norman, Bryan A; Nourollahi, Sevnaz; Chen, Sheng-I; Brown, Shawn T; Claypool, Erin G; Connor, Diana L; Schmitz, Michelle M; Rajgopal, Jayant; Wateska, Angela R; Lee, Bruce Y
2013-10-25
The challenge of keeping vaccines cold at health posts given the unreliability of power sources in many low- and middle-income countries and the expense and maintenance requirements of solar refrigerators has motivated the development of passive cold storage devices (PCDs), containers that keep vaccines cold without using an active energy source. With different PCDs under development, manufacturers, policymakers and funders need guidance on how varying different PCD characteristics may affect the devices' cost and utility. We developed an economic spreadsheet model representing the lowest two levels of a typical Expanded Program on Immunization (EPI) vaccine supply chain: a district store, the immunization locations that the district store serves, and the transport vehicles that operate between the district store and the immunization locations. The model compares the use of three vaccine storage device options [(1) portable PCDs, (2) stationary PCDs, or (3) solar refrigerators] and allows the user to vary different device (e.g., size and cost) and scenario characteristics (e.g., catchment area population size and vaccine schedule). For a sample set of select scenarios and equipment specification, we found the portable PCD to generally be better suited to populations of 5,000 or less. The stationary PCD replenished once per month can be a robust design especially with a 35L capacity and a cost of $2,500 or less. The solar device was generally a reasonable alternative for most of the scenarios explored if the cost was $2,100 or less (including installation). No one device type dominated over all explored circumstances. Therefore, the best device may vary from country-to-country and location-to-location within a country. This study introduces a quantitative model to help guide PCD development. Although our selected set of explored scenarios and device designs was not exhaustive, future explorations can further alter model input values to represent additional scenarios and device designs. Copyright © 2013 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... Representatives on the Device Good Manufacturing Practice Advisory Committee AGENCY: Food and Drug Administration... Device Good Manufacturing Practice Advisory Committee (DGMPAC) in the Center for Devices and Radiological... regarding good manufacturing practices governing the methods used in, and the facilities and controls used...
NASA Technical Reports Server (NTRS)
Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Mondy, Timothy K.;
2017-01-01
Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
Combustion products generating and metering device
NASA Technical Reports Server (NTRS)
Wiberg, R. E.; Klisch, J. A.
1974-01-01
Device simulates incipient fire conditions in closely-controlled adjustable manner, to give predetermined degree of intensity at selected locations throughout area, and to verify that detection system will respond. Device can be used with and for cross calibration and experimentation in conjunction with commercially available products of combustion analyzing meters.
2014-07-01
Device Fabrication The migration devices were fabricated at the Cornell NanoScale Science and Technology Facility (CNF) using standard lithography ...mutations interfere with tissue-specific genes: lamin mutations may inhibit binding to tissue-specific factors [27] or lead to abnormal gene activation...mutations associated with stri- ated muscle disease can interfere with coupling to SUN proteins [77,78], emerin [59,77], Klaroid (a Drosophila nesprin
Agapova, Maria; Bresnahan, Brian W; Linnau, Ken F; Garrison, Louis P; Higashi, Mitchell; Kessler, Larry; Devine, Beth
2017-05-01
Diagnostic imaging has many effects and there is no common definition of value in diagnostic radiology. As benefit-risk trade-offs are rarely made explicit, it is not clear which framework is used in clinical guideline development. We describe initial steps toward the creation of a benefit-risk framework for diagnostic radiology. We performed a literature search and an online survey of physicians to identify and collect benefit-risk criteria (BRC) relevant to diagnostic imaging tests. We operationalized a process for selection of BRC with the use of four clinical use case scenarios that vary by diagnostic alternatives and clinical indication. Respondent BRC selections were compared across clinical scenarios and between radiologists and nonradiologists. Thirty-six BRC were identified and organized into three domains: (1) those that account for differences attributable only to the test or device (n = 17); (2) those that account for clinical management and provider experiences (n = 12); and (3) those that capture patient experience (n = 7). Forty-eight survey participants selected 22 criteria from the initial list in the survey (9-11 per case). Engaging ordering physicians increased the number of criteria selected in each of the four clinical scenarios presented. We developed a process for standardizing selection of BRC in guideline development. These results suggest that a process relying on elements of comparative effectiveness and the use of standardized BRC may ensure consistent examination of differences among alternatives by way of making explicit implicit trade-offs that otherwise enter the decision-making space and detract from consistency and transparency. These findings also highlight the need for multidisciplinary teams that include input from ordering physicians. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Battery self-warming mechanism using the inverter and the battery main disconnect circuitry
Ashtiani, Cyrus N.; Stuart, Thomas A.
2005-04-19
An apparatus connected to an energy storage device for powering an electric motor and optionally providing a warming function for the energy storage device is disclosed. The apparatus includes a circuit connected to the electric motor and the energy storage device for generating a current. The apparatus also includes a switching device operably associated with the circuit for selectively directing the current to one of the electric motor and the energy storage device.
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. House Committee on Education and Labor.
Some forms of assistive device technology are not available to many disabled children or adults because there is not a centralized system to link the technology with those who need it. This hearing explores ways to promote widespread availability of assistive devices. Examined are types of devices, the costs of such devices, methods of…
Forrest, Stephen R; Zimmerman, Jeramy; Lee, Kyusang; Shiu, Kuen-Ting
2015-01-06
There is disclosed methods of making photosensitive devices, such as flexible photovoltaic (PV) devices, through the use of epitaxial liftoff. Also described herein are methods of preparing flexible PV devices comprising a structure having a growth substrate, wherein the selective etching of protective layers yields a smooth growth substrate that us suitable for reuse.
Forrest, Stephen R; Zimmerman, Jeramy; Lee, Kyusang; Shiu, Kuen-Ting
2013-02-19
There is disclosed methods of making photosensitive devices, such as flexible photovoltaic (PV) devices, through the use of epitaxial liftoff. Also described herein are methods of preparing flexible PV devices comprising a structure having a growth substrate, wherein the selective etching of protective layers yields a smooth growth substrate that us suitable for reuse.
Membrane device and process for mass exchange, separation, and filtration
Liu, Wei; Canfield, Nathan L.
2016-11-15
A membrane device and processes for fabrication and for using are disclosed. The membrane device may include a number of porous metal membranes that provide a high membrane surface area per unit volume. The membrane device provides various operation modes that enhance throughput and selectivity for mass exchange, mass transfer, separation, and/or filtration applications between feed flow streams and permeate flow streams.
Sandoe, Jonathan A T; Barlow, Gavin; Chambers, John B; Gammage, Michael; Guleri, Achyut; Howard, Philip; Olson, Ewan; Perry, John D; Prendergast, Bernard D; Spry, Michael J; Steeds, Richard P; Tayebjee, Muzahir H; Watkin, Richard
2015-02-01
Infections related to implantable cardiac electronic devices (ICEDs), including pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices, are increasing in incidence in the USA and are likely to increase in the UK, because more devices are being implanted. These devices have both intravascular and extravascular components and infection can involve the generator, device leads and native cardiac structures or various combinations. ICED infections can be life-threatening, particularly when associated with endocardial infection, and all-cause mortality of up to 35% has been reported. Like infective endocarditis, ICED infections can be difficult to diagnose and manage. This guideline aims to (i) improve the quality of care provided to patients with ICEDs, (ii) provide an educational resource for all relevant healthcare professionals, (iii) encourage a multidisciplinary approach to ICED infection management, (iv) promote a standardized approach to the diagnosis, management, surveillance and prevention of ICED infection through pragmatic evidence-rated recommendations, and (v) advise on future research projects/audit. The guideline is intended to assist in the clinical care of patients with suspected or confirmed ICED infection in the UK, to inform local infection prevention and treatment policies and guidelines and to be used in the development of educational and training material by the relevant professional societies. The questions covered by the guideline are presented at the beginning of each section. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Addressing Research and Development Gaps for Plasma-Material Interactions with Linear Plasma Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, Juergen
Plasma-material interactions in future fusion reactors have been identified as a knowledge gap to be dealt with before any next step device past ITER can be built. The challenges are manifold. They are related to power dissipation so that the heat fluxes to the plasma-facing components can be kept at technologically feasible levels; maximization of the lifetime of divertor plasma-facing components that allow for steadystate operation in a reactor to reach the neutron fluence required; the tritium inventory (storage) in the plasma-facing components, which can lead to potential safety concerns and reduction in the fuel efficiency; and it is relatedmore » to the technology of the plasma-facing components itself, which should demonstrate structural integrity under the high temperatures and high neutron fluence. While the dissipation of power exhaust can and should be addressed in high power toroidal devices, the interaction of the plasma with the materials can be best addressed in dedicated linear devices due to their cost effectiveness and ability to address urgent research and development gaps more timely. However, new linear plasma devices are needed to investigate the PMI under fusion reactor conditions and test novel plasma-facing components. Existing linear devices are limited either in their flux, their reactor-relevant plasma transport regimes in front of the target, their fluence, or their ability to test material samples a priori exposed to high neutron fluence. The proposed Material Plasma Exposure eXperiment (MPEX) is meant to address those deficiencies and will be designed to fulfill the fusion reactor-relevant plasma parameters as well as the ability to expose a priori neutron activated materials to plasmas.« less
New, small, fast acting blood glucose meters--an analytical laboratory evaluation.
Weitgasser, Raimund; Hofmann, Manuela; Gappmayer, Brigitta; Garstenauer, Christa
2007-09-22
Patients and medical personnel are eager to use blood glucose meters that are easy to handle and fast acting. We questioned whether accuracy and precision of these new, small and light weight devices would meet analytical laboratory standards and tested four meters with the above mentioned conditions. Approximately 300 capillary blood samples were collected and tested using two devices of each brand and two different types of glucose test strips. Blood from the same samples was used for comparison. Results were evaluated using maximum deviation of 5% and 10% from the comparative method, the error grid analysis, the overall deviation of the devices, the linear regression analysis as well as the CVs for measurement in series. Of all 1196 measurements a deviation of less than 5% resp. 10% from the reference method was found for the FreeStyle (FS) meter in 69.5% and 96%, the Glucocard X Meter (GX) in 44% and 75%, the One Touch Ultra (OT) in 29% and 60%, the Wellion True Track (WT) in 28.5% and 58%. The error grid analysis gave 99.7% for FS, 99% for GX, 98% for OT and 97% for WT in zone A. The remainder of the values lay within zone B. Linear regression analysis resembled these results. CVs for measurement in series showed higher deviations for OT and WT compared to FS and GX. The four new, small and fast acting glucose meters fulfil clinically relevant analytical laboratory requirements making them appropriate for use by medical personnel. However, with regard to the tight and restrictive limits of the ADA recommendations, the devices are still in need of improvement. This should be taken into account when the devices are used by primarily inexperienced persons and is relevant for further industrial development of such devices.
Free Electron coherent sources: From microwave to X-rays
NASA Astrophysics Data System (ADS)
Dattoli, Giuseppe; Di Palma, Emanuele; Pagnutti, Simonetta; Sabia, Elio
2018-04-01
The term Free Electron Laser (FEL) will be used, in this paper, to indicate a wide collection of devices aimed at providing coherent electromagnetic radiation from a beam of "free" electrons, unbound at the atomic or molecular states. This article reviews the similarities that link different sources of coherent radiation across the electromagnetic spectrum from microwaves to X-rays, and compares the analogies with conventional laser sources. We explore developing a point of view that allows a unified analytical treatment of these devices, by the introduction of appropriate global variables (e.g. gain, saturation intensity, inhomogeneous broadening parameters, longitudinal mode coupling strength), yielding a very effective way for the determination of the relevant design parameters. The paper looks also at more speculative aspects of FEL physics, which may address the relevance of quantum effects in the lasing process.
Harvey, Scott D [Kennewick, WA
2011-06-21
A process and sensor device are disclosed that employ metal .beta.-diketonate polymers to selectively capture gas-phase explosives and weaponized chemical agents in a sampling area or volume. The metal .beta.-diketonate polymers can be applied to surfaces in various analytical formats for detection of: improvised explosive devices, unexploded ordinance, munitions hidden in cargo holds, explosives, and chemical weapons in public areas.
Programmable in vivo selection of arbitrary DNA sequences.
Ben Yehezkel, Tuval; Biezuner, Tamir; Linshiz, Gregory; Mazor, Yair; Shapiro, Ehud
2012-01-01
The extraordinary fidelity, sensory and regulatory capacity of natural intracellular machinery is generally confined to their endogenous environment. Nevertheless, synthetic bio-molecular components have been engineered to interface with the cellular transcription, splicing and translation machinery in vivo by embedding functional features such as promoters, introns and ribosome binding sites, respectively, into their design. Tapping and directing the power of intracellular molecular processing towards synthetic bio-molecular inputs is potentially a powerful approach, albeit limited by our ability to streamline the interface of synthetic components with the intracellular machinery in vivo. Here we show how a library of synthetic DNA devices, each bearing an input DNA sequence and a logical selection module, can be designed to direct its own probing and processing by interfacing with the bacterial DNA mismatch repair (MMR) system in vivo and selecting for the most abundant variant, regardless of its function. The device provides proof of concept for programmable, function-independent DNA selection in vivo and provides a unique example of a logical-functional interface of an engineered synthetic component with a complex endogenous cellular system. Further research into the design, construction and operation of synthetic devices in vivo may lead to other functional devices that interface with other complex cellular processes for both research and applied purposes.
Andersen, Pia; Lindgaard, Anne-Mette; Prgomet, Mirela; Creswick, Nerida
2009-01-01
Background Selecting the right mix of stationary and mobile computing devices is a significant challenge for system planners and implementers. There is very limited research evidence upon which to base such decisions. Objective We aimed to investigate the relationships between clinician role, clinical task, and selection of a computer hardware device in hospital wards. Methods Twenty-seven nurses and eight doctors were observed for a total of 80 hours as they used a range of computing devices to access a computerized provider order entry system on two wards at a major Sydney teaching hospital. Observers used a checklist to record the clinical tasks completed, devices used, and location of the activities. Field notes were also documented during observations. Semi-structured interviews were conducted after observation sessions. Assessment of the physical attributes of three devices—stationary PCs, computers on wheels (COWs) and tablet PCs—was made. Two types of COWs were available on the wards: generic COWs (laptops mounted on trolleys) and ergonomic COWs (an integrated computer and cart device). Heuristic evaluation of the user interfaces was also carried out. Results The majority (93.1%) of observed nursing tasks were conducted using generic COWs. Most nursing tasks were performed in patients’ rooms (57%) or in the corridors (36%), with a small percentage at a patient’s bedside (5%). Most nursing tasks related to the preparation and administration of drugs. Doctors on ward rounds conducted 57.3% of observed clinical tasks on generic COWs and 35.9% on tablet PCs. On rounds, 56% of doctors’ tasks were performed in the corridors, 29% in patients’ rooms, and 3% at the bedside. Doctors not on a ward round conducted 93.6% of tasks using stationary PCs, most often within the doctors’ office. Nurses and doctors were observed performing workarounds, such as transcribing medication orders from the computer to paper. Conclusions The choice of device was related to clinical role, nature of the clinical task, degree of mobility required, including where task completion occurs, and device design. Nurses’ work, and clinical tasks performed by doctors during ward rounds, require highly mobile computer devices. Nurses and doctors on ward rounds showed a strong preference for generic COWs over all other devices. Tablet PCs were selected by doctors for only a small proportion of clinical tasks. Even when using mobile devices clinicians completed a very low proportion of observed tasks at the bedside. The design of the devices and ward space configurations place limitations on how and where devices are used and on the mobility of clinical work. In such circumstances, clinicians will initiate workarounds to compensate. In selecting hardware devices, consideration should be given to who will be using the devices, the nature of their work, and the physical layout of the ward. PMID:19674959
Identifying relevant group of miRNAs in cancer using fuzzy mutual information.
Pal, Jayanta Kumar; Ray, Shubhra Sankar; Pal, Sankar K
2016-04-01
MicroRNAs (miRNAs) act as a major biomarker of cancer. All miRNAs in human body are not equally important for cancer identification. We propose a methodology, called FMIMS, which automatically selects the most relevant miRNAs for a particular type of cancer. In FMIMS, miRNAs are initially grouped by using a SVM-based algorithm; then the group with highest relevance is determined and the miRNAs in that group are finally ranked for selection according to their redundancy. Fuzzy mutual information is used in computing the relevance of a group and the redundancy of miRNAs within it. Superiority of the most relevant group to all others, in deciding normal or cancer, is demonstrated on breast, renal, colorectal, lung, melanoma and prostate data. The merit of FMIMS as compared to several existing methods is established. While 12 out of 15 selected miRNAs by FMIMS corroborate with those of biological investigations, three of them viz., "hsa-miR-519," "hsa-miR-431" and "hsa-miR-320c" are possible novel predictions for renal cancer, lung cancer and melanoma, respectively. The selected miRNAs are found to be involved in disease-specific pathways by targeting various genes. The method is also able to detect the responsible miRNAs even at the primary stage of cancer. The related code is available at http://www.jayanta.droppages.com/FMIMS.html .
For the general internist: a review of relevant 2013 innovations in medical education.
Roy, Brita; Willett, Lisa L; Bates, Carol; Duffy, Briar; Dunn, Kathel; Karani, Reena; Chheda, Shobhina G
2015-04-01
We conducted a review of articles published in 2013 to identify high-quality research in medical education that was relevant to general medicine education practice. Our review team consisted of six general internists with expertise in medical education of varying ranks, as well as a professional medical librarian. We manually searched 15 journals in pairs, and performed an online search using the PubMed search engine for all original research articles in medical education published in 2013. From the total 4,181 citations identified, we selected 65 articles considered most relevant to general medicine educational practice. Each team member then independently reviewed and rated the quality of each selected article using the modified Medical Education Research Study Quality Instrument. We then reviewed the quality and relevance of each selected study and grouped them into categories of propensity for inclusion. Nineteen studies were felt to be of adequate quality and were of moderate to high propensity for inclusion. Team members then independently voted for studies they felt to be of the highest relevance and quality within the 19 selected studies. The ten articles with the greatest number of votes were included in the review. We categorized the studies into five general themes: Improving Clinical Skills in UME, Inpatient Clinical Teaching Methods, Advancements in Continuity Clinic, Handoffs/Transitions in Care, and Trainee Assessment. Most studies in our review of the 2013 literature in general medical education were limited to single institutions and non-randomized study designs; we identified significant limitations of each study. Selected articles may inform future research and practice of medical educators.
NASA Astrophysics Data System (ADS)
Malakootian, Mohammad; Amirmahani, Najmeh; Yazdanpanah, Ghazal; Nasiri, Alireza; Asadipour, Ali; Ebrahimi, Ahmad; Darvish Moghaddam, Sodaif
2017-12-01
Increased awareness in society of the consequences of contaminants in drinking water has created a demand for household water treatment systems, which provide higher quality water, to spread. The aim of this study was to evaluate the performance of household water treatment systems used in Kerman for the removal of cations and anions. Various brands of home water treatment devices commonly used in Kerman were selected, with one device chosen from each brand for study. In cases in which the devices were used extensively, samples were selected with filters that had been changed in proper time, based on the device's operational instructions. The samples were selected from homes in the center and four geographical directions of Kerman. Then, sampling was conducted in three stages of input and output water of each device. For each of the samples, parameters were measured, such as chloride, sulfate, bicarbonate, calcium, magnesium, hardness, sodium, nitrate and nitrite (mg/L), temperature (°C), and pH. The average removal efficiency of different parameters by 14 brands in Kerman, which include chloride ions, sulfate, bicarbonate, calcium, magnesium, sodium, nitrites, nitrates, and total hardness, was obtained at 68.48, 85, 67, 61.21, 78.97, 80.24, 32.59, 66.83, and 69.38%, respectively. The amount of sulfate, bicarbonate, chloride, calcium, magnesium, hardness, sodium, and nitrate in the output water of household water treatment systems was less than the input water of these devices, but nitrite concentration in the output of some devices was more than the input water and showed a significant difference ( p > 0.05).
Wang, Sibo; Ren, Zheng; Guo, Yanbing; ...
2016-03-21
We report the scalable three-dimensional (3-D) integration of functional nanostructures into applicable platforms represents a promising technology to meet the ever-increasing demands of fabricating high performance devices featuring cost-effectiveness, structural sophistication and multi-functional enabling. Such an integration process generally involves a diverse array of nanostructural entities (nano-entities) consisting of dissimilar nanoscale building blocks such as nanoparticles, nanowires, and nanofilms made of metals, ceramics, or polymers. Various synthetic strategies and integration methods have enabled the successful assembly of both structurally and functionally tailored nano-arrays into a unique class of monolithic devices. The performance of nano-array based monolithic devices is dictated bymore » a few important factors such as materials substrate selection, nanostructure composition and nano-architecture geometry. Therefore, the rational material selection and nano-entity manipulation during the nano-array integration process, aiming to exploit the advantageous characteristics of nanostructures and their ensembles, are critical steps towards bridging the design of nanostructure integrated monolithic devices with various practical applications. In this article, we highlight the latest research progress of the two-dimensional (2-D) and 3-D metal and metal oxide based nanostructural integrations into prototype devices applicable with ultrahigh efficiency, good robustness and improved functionality. Lastly, selective examples of nano-array integration, scalable nanomanufacturing and representative monolithic devices such as catalytic converters, sensors and batteries will be utilized as the connecting dots to display a roadmap from hierarchical nanostructural assembly to practical nanotechnology implications ranging from energy, environmental, to chemical and biotechnology areas.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Sibo; Ren, Zheng; Guo, Yanbing
We report the scalable three-dimensional (3-D) integration of functional nanostructures into applicable platforms represents a promising technology to meet the ever-increasing demands of fabricating high performance devices featuring cost-effectiveness, structural sophistication and multi-functional enabling. Such an integration process generally involves a diverse array of nanostructural entities (nano-entities) consisting of dissimilar nanoscale building blocks such as nanoparticles, nanowires, and nanofilms made of metals, ceramics, or polymers. Various synthetic strategies and integration methods have enabled the successful assembly of both structurally and functionally tailored nano-arrays into a unique class of monolithic devices. The performance of nano-array based monolithic devices is dictated bymore » a few important factors such as materials substrate selection, nanostructure composition and nano-architecture geometry. Therefore, the rational material selection and nano-entity manipulation during the nano-array integration process, aiming to exploit the advantageous characteristics of nanostructures and their ensembles, are critical steps towards bridging the design of nanostructure integrated monolithic devices with various practical applications. In this article, we highlight the latest research progress of the two-dimensional (2-D) and 3-D metal and metal oxide based nanostructural integrations into prototype devices applicable with ultrahigh efficiency, good robustness and improved functionality. Lastly, selective examples of nano-array integration, scalable nanomanufacturing and representative monolithic devices such as catalytic converters, sensors and batteries will be utilized as the connecting dots to display a roadmap from hierarchical nanostructural assembly to practical nanotechnology implications ranging from energy, environmental, to chemical and biotechnology areas.« less
Vehicle electrical system state controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bissontz, Jay E.
A motor vehicle electrical power distribution system includes a plurality of distribution sub-systems, an electrical power storage sub-system and a plurality of switching devices for selective connection of elements of and loads on the power distribution system to the electrical power storage sub-system. A state transition initiator provides inputs to control system operation of switching devices to change the states of the power distribution system. The state transition initiator has a plurality of positions selection of which can initiate a state transition. The state transition initiator can emulate a four position rotary ignition switch. Fail safe power cutoff switches providemore » high voltage switching device protection.« less
Proximal sensing of plant-pathogen interactions in spring barley with three fluorescence techniques.
Leufen, Georg; Noga, Georg; Hunsche, Mauricio
2014-06-24
In the last years fluorescence spectroscopy has come to be viewed as an essential approach in key research fields of applied plant sciences. However, the quantity and particularly the quality of information produced by different equipment might vary considerably. In this study we investigate the potential of three optical devices for the proximal sensing of plant-pathogen interactions in four genotypes of spring barley. For this purpose, the fluorescence lifetime, the image-resolved multispectral fluorescence and selected indices of a portable multiparametric fluorescence device were recorded at 3, 6, and 9 days after inoculation (dai) from healthy leaves as well as from leaves inoculated with powdery mildew (Blumeria graminis) or leaf rust (Puccinia hordei). Genotype-specific responses to pathogen infections were revealed already at 3 dai by higher fluorescence mean lifetimes in the spectral range from 410 to 560 nm in the less susceptible varieties. Noticeable pathogen-induced modifications were also revealed by the 'Blue-to-Far-Red Fluorescence Ratio' and the 'Simple Fluorescence Ratio'. Particularly in the susceptible varieties the differences became more evident in the time-course of the experiment i.e., following the pathogen development. The relevance of the blue and green fluorescence to exploit the plant-pathogen interaction was demonstrated by the multispectral fluorescence imaging system. As shown, mildewed leaves were characterized by exceptionally high blue fluorescence, contrasting the values observed in rust inoculated leaves. Further, we confirm that the intensity of green fluorescence depends on the pathogen infection and the stage of disease development; this information might allow a differentiation of both diseases. Moreover, our results demonstrate that the detection area might influence the quality of the information, although it had a minor impact only in the current study. Finally, we highlight the relevance of different excitation-emission channels to better understand and evaluate plant-physiological alterations due to pathogen infections.
Preparation for a first-in-man lentivirus trial in patients with cystic fibrosis
Alton, Eric W F W; Beekman, Jeffery M; Boyd, A Christopher; Brand, June; Carlon, Marianne S; Connolly, Mary M; Chan, Mario; Conlon, Sinead; Davidson, Heather E; Davies, Jane C; Davies, Lee A; Dekkers, Johanna F; Doherty, Ann; Gea-Sorli, Sabrina; Gill, Deborah R; Griesenbach, Uta; Hasegawa, Mamoru; Higgins, Tracy E; Hironaka, Takashi; Hyndman, Laura; McLachlan, Gerry; Inoue, Makoto; Hyde, Stephen C; Innes, J Alastair; Maher, Toby M; Moran, Caroline; Meng, Cuixiang; Paul-Smith, Michael C; Pringle, Ian A; Pytel, Kamila M; Rodriguez-Martinez, Andrea; Schmidt, Alexander C; Stevenson, Barbara J; Sumner-Jones, Stephanie G; Toshner, Richard; Tsugumine, Shu; Wasowicz, Marguerite W; Zhu, Jie
2017-01-01
We have recently shown that non-viral gene therapy can stabilise the decline of lung function in patients with cystic fibrosis (CF). However, the effect was modest, and more potent gene transfer agents are still required. Fuson protein (F)/Hemagglutinin/Neuraminidase protein (HN)-pseudotyped lentiviral vectors are more efficient for lung gene transfer than non-viral vectors in preclinical models. In preparation for a first-in-man CF trial using the lentiviral vector, we have undertaken key translational preclinical studies. Regulatory-compliant vectors carrying a range of promoter/enhancer elements were assessed in mice and human air–liquid interface (ALI) cultures to select the lead candidate; cystic fibrosis transmembrane conductance receptor (CFTR) expression and function were assessed in CF models using this lead candidate vector. Toxicity was assessed and ‘benchmarked’ against the leading non-viral formulation recently used in a Phase IIb clinical trial. Integration site profiles were mapped and transduction efficiency determined to inform clinical trial dose-ranging. The impact of pre-existing and acquired immunity against the vector and vector stability in several clinically relevant delivery devices was assessed. A hybrid promoter hybrid cytosine guanine dinucleotide (CpG)- free CMV enhancer/elongation factor 1 alpha promoter (hCEF) consisting of the elongation factor 1α promoter and the cytomegalovirus enhancer was most efficacious in both murine lungs and human ALI cultures (both at least 2-log orders above background). The efficacy (at least 14% of airway cells transduced), toxicity and integration site profile supports further progression towards clinical trial and pre-existing and acquired immune responses do not interfere with vector efficacy. The lead rSIV.F/HN candidate expresses functional CFTR and the vector retains 90–100% transduction efficiency in clinically relevant delivery devices. The data support the progression of the F/HN-pseudotyped lentiviral vector into a first-in-man CF trial in 2017. PMID:27852956
O'Malley, Marcia K; Ro, Tony; Levin, Harvey S
2006-12-01
To describe 2 new ways of assessing and inducing neuroplasticity in the human brain--transcranial magnetic stimulation (TMS) and robotics--and to investigate and promote the recovery of motor function after brain damage. We identified recent articles and books directly bearing on TMS and robotics. Articles using these tools for purposes other than rehabilitation were excluded. From these studies, we emphasize the methodologic and technical details of these tools as applicable for assessing and inducing plasticity. Because both tools have only recently been used for rehabilitation, the majority of the articles selected for this review have been published only within the last 10 years. We used the PubMed and Compendex databases to find relevant peer-reviewed studies for this review. The studies were required to be relevant to rehabilitation and to use TMS or robotics methodologies. Guidelines were applied via independent extraction by multiple observers. Despite the limited amount of research using these procedures for assessing and inducing neuroplasticity, there is growing evidence that both TMS and robotics can be very effective, inexpensive, and convenient ways for assessing and inducing rehabilitation. Although TMS has primarily been used as an assessment tool for motor function, an increasing number of studies are using TMS as a tool to directly induce plasticity and improve motor function. Similarly, robotic devices have been used for rehabilitation because of their suitability for delivery of highly repeatable training. New directions in robotics-assisted rehabilitation are taking advantage of novel measurements that can be acquired via the devices, enabling unique methods of assessment of motor recovery. As refinements in technology and advances in our knowledge continue, TMS and robotics should play an increasing role in assessing and promoting the recovery of function. Ongoing and future studies combining TMS and robotics within the same populations may prove fruitful for a more detailed and comprehensive assessment of the central and peripheral changes in the nervous system during precisely induced recovery.
Reward- and attention-related biasing of sensory selection in visual cortex.
Buschschulte, Antje; Boehler, Carsten N; Strumpf, Hendrik; Stoppel, Christian; Heinze, Hans-Jochen; Schoenfeld, Mircea A; Hopf, Jens-Max
2014-05-01
Attention to task-relevant features leads to a biasing of sensory selection in extrastriate cortex. Features signaling reward seem to produce a similar bias, but how modulatory effects due to reward and attention relate to each other is largely unexplored. To address this issue, it is critical to separate top-down settings defining reward relevance from those defining attention. To this end, we used a visual search paradigm in which the target's definition (attention to color) was dissociated from reward relevance by delivering monetary reward on search frames where a certain task-irrelevant color was combined with the target-defining color to form the target object. We assessed the state of neural biasing for the attended and reward-relevant color by analyzing the neuromagnetic brain response to asynchronously presented irrelevant distractor probes drawn in the target-defining color, the reward-relevant color, and a completely irrelevant color as a reference. We observed that for the prospect of moderate rewards, the target-defining color but not the reward-relevant color produced a selective enhancement of the neuromagnetic response between 180 and 280 msec in ventral extrastriate visual cortex. Increasing reward prospect caused a delayed attenuation (220-250 msec) of the response to reward probes, which followed a prior (160-180 msec) response enhancement in dorsal ACC. Notably, shorter latency responses in dorsal ACC were associated with stronger attenuation in extrastriate visual cortex. Finally, an analysis of the brain response to the search frames revealed that the presence of the reward-relevant color in search distractors elicited an enhanced response that was abolished after increasing reward size. The present data together indicate that when top-down definitions of reward relevance and attention are separated, the behavioral significance of reward-associated features is still rapidly coded in higher-level cortex areas, thereby commanding effective top-down inhibitory control to counter a selection bias for those features in extrastriate visual cortex.
A generic approach for examining the effectiveness of traffic control devices in school zones.
Zhao, Xiaohua; Li, Jiahui; Ding, Han; Zhang, Guohui; Rong, Jian
2015-09-01
The effectiveness and performance of traffic control devices in school zones have been impacted significantly by many factors, such as driver behavioral attributes, roadway geometric features, environmental characteristics, weather and visibility conditions, region-wide traffic regulations and policies, control modes, etc. When deploying traffic control devices in school zones, efforts are needed to clarify: (1) whether traffic control device installation is warranted; and (2) whether other device effectively complements this traffic control device and strengthens its effectiveness. In this study, a generic approach is developed to examine and evaluate the effectiveness of various traffic control devices deployed in school zones through driving simulator-based experiments. A Traffic Control Device Selection Model (TCDSM) is developed and two representative school zones are selected as the testbed in Beijing for driving simulation implementation to enhance its applicability. Statistical analyses are conducted to extract the knowledge from test data recorded by a driving simulator. Multiple measures of effectiveness (MOEs) are developed and adopted including average speed, relative speed difference, and standard deviation of acceleration for traffic control device performance quantification. The experimental tests and analysis results reveal that the appropriateness of the installation of certain traffic control devices can be statistically verified by TCDSM. The proposed approach provides a generic framework to assess traffic control device performance in school zones including experiment design, statistical formulation, data analysis, simulation model implementation, data interpretation, and recommendation development. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
McCrudden, Matthew T.; Stenseth, Tonje; Bråten, Ivar; Strømsø, Helge I.
2016-01-01
This mixed methods study investigated the extent to which author expertise and content relevance were salient to secondary Norwegian students (N = 153) when they selected documents that pertained to more familiar and less familiar topics. Quantitative results indicated that author expertise was more salient for the less familiar topic (nuclear…
Gentile, Francesco; Ferrara, Lorenzo; Villani, Marco; Bettelli, Manuele; Iannotta, Salvatore; Zappettini, Andrea; Cesarelli, Mario; Di Fabrizio, Enzo; Coppedè, Nicola
2016-01-12
PSS is a conductive polymer that can be integrated into last generation Organic Electrochemical Transistor (OECT) devices for biological inspection, identification and analysis. While a variety of reports in literature demonstrated the chemical and biological sensitivity of these devices, still their ability in resolving complex mixtures remains controversial. Similar OECT devices display good time dynamics behavior but lack spatial resolution. In this work, we integrated PSS with patterns of super-hydrophobic pillars in which a finite number of those pillars is independently controlled for site-selective measurement of a solution. We obtained a multifunctional, hierarchical OECT device that bridges the micro- to the nano-scales for specific, combined time and space resolved analysis of the sample. Due to super-hydrophobic surface properties, the biological species in the drop are driven by convection, diffusion, and the externally applied electric field: the balance/unbalance between these forces will cause the molecules to be transported differently within its volume depending on particle size thus realizing a size-selective separation. Within this framework, the separation and identification of two different molecules, namely Cetyl Trimethyl Ammonium Bromid (CTAB) and adrenaline, in a biological mixture have been demonstrated, showing that geometrical control at the micro-nano scale impart unprecedented selectivity to the devices.
Gentile, Francesco; Ferrara, Lorenzo; Villani, Marco; Bettelli, Manuele; Iannotta, Salvatore; Zappettini, Andrea; Cesarelli, Mario; Di Fabrizio, Enzo; Coppedè, Nicola
2016-01-01
PEDOT:PSS is a conductive polymer that can be integrated into last generation Organic Electrochemical Transistor (OECT) devices for biological inspection, identification and analysis. While a variety of reports in literature demonstrated the chemical and biological sensitivity of these devices, still their ability in resolving complex mixtures remains controversial. Similar OECT devices display good time dynamics behavior but lack spatial resolution. In this work, we integrated PEDOT:PSS with patterns of super-hydrophobic pillars in which a finite number of those pillars is independently controlled for site-selective measurement of a solution. We obtained a multifunctional, hierarchical OECT device that bridges the micro- to the nano-scales for specific, combined time and space resolved analysis of the sample. Due to super-hydrophobic surface properties, the biological species in the drop are driven by convection, diffusion, and the externally applied electric field: the balance/unbalance between these forces will cause the molecules to be transported differently within its volume depending on particle size thus realizing a size-selective separation. Within this framework, the separation and identification of two different molecules, namely Cetyl Trimethyl Ammonium Bromid (CTAB) and adrenaline, in a biological mixture have been demonstrated, showing that geometrical control at the micro-nano scale impart unprecedented selectivity to the devices. PMID:26753611
NASA Astrophysics Data System (ADS)
Gentile, Francesco; Ferrara, Lorenzo; Villani, Marco; Bettelli, Manuele; Iannotta, Salvatore; Zappettini, Andrea; Cesarelli, Mario; di Fabrizio, Enzo; Coppedè, Nicola
2016-01-01
PEDOT:PSS is a conductive polymer that can be integrated into last generation Organic Electrochemical Transistor (OECT) devices for biological inspection, identification and analysis. While a variety of reports in literature demonstrated the chemical and biological sensitivity of these devices, still their ability in resolving complex mixtures remains controversial. Similar OECT devices display good time dynamics behavior but lack spatial resolution. In this work, we integrated PEDOT:PSS with patterns of super-hydrophobic pillars in which a finite number of those pillars is independently controlled for site-selective measurement of a solution. We obtained a multifunctional, hierarchical OECT device that bridges the micro- to the nano-scales for specific, combined time and space resolved analysis of the sample. Due to super-hydrophobic surface properties, the biological species in the drop are driven by convection, diffusion, and the externally applied electric field: the balance/unbalance between these forces will cause the molecules to be transported differently within its volume depending on particle size thus realizing a size-selective separation. Within this framework, the separation and identification of two different molecules, namely Cetyl Trimethyl Ammonium Bromid (CTAB) and adrenaline, in a biological mixture have been demonstrated, showing that geometrical control at the micro-nano scale impart unprecedented selectivity to the devices.
A Single-Molecule Barcoding System using Nanoslits for DNA Analysis
NASA Astrophysics Data System (ADS)
Jo, Kyubong; Schramm, Timothy M.; Schwartz, David C.
Single DNA molecule approaches are playing an increasingly central role in the analytical genomic sciences because single molecule techniques intrinsically provide individualized measurements of selected molecules, free from the constraints of bulk techniques, which blindly average noise and mask the presence of minor analyte components. Accordingly, a principal challenge that must be addressed by all single molecule approaches aimed at genome analysis is how to immobilize and manipulate DNA molecules for measurements that foster construction of large, biologically relevant data sets. For meeting this challenge, this chapter discusses an integrated approach for microfabricated and nanofabricated devices for the manipulation of elongated DNA molecules within nanoscale geometries. Ideally, large DNA coils stretch via nanoconfinement when channel dimensions are within tens of nanometers. Importantly, stretched, often immobilized, DNA molecules spanning hundreds of kilobase pairs are required by all analytical platforms working with large genomic substrates because imaging techniques acquire sequence information from molecules that normally exist in free solution as unrevealing random coils resembling floppy balls of yarn. However, nanoscale devices fabricated with sufficiently small dimensions fostering molecular stretching make these devices impractical because of the requirement of exotic fabrication technologies, costly materials, and poor operational efficiencies. In this chapter, such problems are addressed by discussion of a new approach to DNA presentation and analysis that establishes scaleable nanoconfinement conditions through reduction of ionic strength; stiffening DNA molecules thus enabling their arraying for analysis using easily fabricated devices that can also be mass produced. This new approach to DNA nanoconfinement is complemented by the development of a novel labeling scheme for reliable marking of individual molecules with fluorochrome labels, creating molecular barcodes, which are efficiently read using fluorescence resonance energy transfer techniques for minimizing noise from unincorporated labels. As such, our integrative approach for the realization of genomic analysis through nanoconfinement, named nanocoding, was demonstrated through the barcoding and mapping of bacterial artificial chromosomal molecules, thereby providing the basis for a high-throughput platform competent for whole genome investigations.
Bartoli, Carlo R.; Koenig, Steven C.; Ionan, Constantine; Gillars, Kevin J.; Mitchell, Mike E.; Austin, Erle H.; Gray, Laman A.; Pantalos, George M.
2014-01-01
OBJECTIVE Despite progress with adult ventricular assist devices (VADs), limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation (ECMO) remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, ECMO was compared to either intraaortic balloon pump (IABP), pulsatile-flow (PF)VAD, or continuous-flow (CF)VAD support in a pediatric heart failure model. DESIGN Experimental. SETTING Large animal laboratory operating room. SUBJECTS Yorkshire piglets (n=47, 11.7±2.6 kg). INTERVENTIONS In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS and MAIN RESULTS Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption (VO2) were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired student t-tests compared baseline and heart failure conditions. One-way repeated-measures ANOVA compared heart failure, device support mode(s), and ECMO. Statistically significant (p<0.05) findings included: 1) improved left ventricular blood supply/demand ratio during PFVAD, CFVAD, and ECMO but not IABP support, 2) improved global myocardial blood supply/demand ratio during PFVAD, and CFVAD but not IABP or ECMO support, and 3) diminished pulsatility during ECMO and CFVAD but not IABP and PFVAD support. A profile of systems-based responses was established for each type of support. CONCLUSIONS Each type of pediatric VAD provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically relevant insight into pediatric mechanical circulatory support and establish an important resource for pediatric device development and patient selection. PMID:24108116
Sagar, Sanjay; Adem, Seid M; Struchen, Benjamin; Loughran, Sarah P; Brunjes, Michael E; Arangua, Lisa; Dalvie, Mohamed Aqiel; Croft, Rodney J; Jerrett, Michael; Moskowitz, Joel M; Kuo, Tony; Röösli, Martin
2018-05-01
The aim of this study was to quantify RF-EMF exposure applying a tested protocol of RF-EMF exposure measurements using portable devices with a high sampling rate in different microenvironments of Switzerland, Ethiopia, Nepal, South Africa, Australia and the United States of America. We used portable measurement devices for assessing RF-EMF exposure in 94 outdoor microenvironments and 18 public transport vehicles. The measurements were taken either by walking with a backpack with the devices at the height of the head and a distance of 20-30 cm from the body, or driving a car with the devices mounted on its roof, which was 170-180 cm above the ground. The measurements were taken for about 30 min while walking and about 15-20 min while driving in each microenvironment, with a sampling rate of once every 4 s (ExpoM-RF) and 5 s (EME Spy 201). Mean total RF-EMF exposure in various outdoor microenvironments varied between 0.23 V/m (non-central residential area in Switzerland) and 1.85 V/m (university area in Australia), and across modes of public transport between 0.32 V/m (bus in rural area in Switzerland) and 0.86 V/m (Auto rickshaw in urban area in Nepal). For most outdoor areas the major exposure contribution was from mobile phone base stations. Otherwise broadcasting was dominant. Uplink from mobile phone handsets was generally very small, except in Swiss trains and some Swiss buses. This study demonstrates high RF-EMF variability between the 94 selected microenvironments from all over the world. Exposure levels tended to increase with increasing urbanity. In most microenvironments downlink from mobile phone base stations is the most relevant contributor. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fusion set selection with surrogate metric in multi-atlas based image segmentation
NASA Astrophysics Data System (ADS)
Zhao, Tingting; Ruan, Dan
2016-02-01
Multi-atlas based image segmentation sees unprecedented opportunities but also demanding challenges in the big data era. Relevant atlas selection before label fusion plays a crucial role in reducing potential performance loss from heterogeneous data quality and high computation cost from extensive data. This paper starts with investigating the image similarity metric (termed ‘surrogate’), an alternative to the inaccessible geometric agreement metric (termed ‘oracle’) in atlas relevance assessment, and probes into the problem of how to select the ‘most-relevant’ atlases and how many such atlases to incorporate. We propose an inference model to relate the surrogates and the oracle geometric agreement metrics. Based on this model, we quantify the behavior of the surrogates in mimicking oracle metrics for atlas relevance ordering. Finally, analytical insights on the choice of fusion set size are presented from a probabilistic perspective, with the integrated goal of including the most relevant atlases and excluding the irrelevant ones. Empirical evidence and performance assessment are provided based on prostate and corpus callosum segmentation.
Organic light emitting devices for illumination
Hack, Michael; Lu, Min-Hao Michael; Weaver, Michael S.
2010-02-16
An organic light emitting device is provided. The device has a plurality of regions, each region having an organic emissive layer adapted to emit a different spectrum of light. The regions in combination emit light suitable for illumination purposes. The area of each region may be selected such that the device is more efficient that an otherwise equivalent device having regions of equal size. The regions may have an aspect ratio of at least about four. All parts of any given region may be driven at the same current.
A Simple and Scalable Fabrication Method for Organic Electronic Devices on Textiles.
Ismailov, Usein; Ismailova, Esma; Takamatsu, Seiichi
2017-03-13
Today, wearable electronics devices combine a large variety of functional, stretchable, and flexible technologies. However, in many cases, these devices cannot be worn under everyday conditions. Therefore, textiles are commonly considered the best substrate to accommodate electronic devices in wearable use. In this paper, we describe how to selectively pattern organic electroactive materials on textiles from a solution in an easy and scalable manner. This versatile deposition technique enables the fabrication of wearable organic electronic devices on clothes.
Method and apparatus to selectively reduce NO.sub.x in an exhaust gas feedstream
Schmieg, Steven J [Troy, MI; Blint, Richard J [Shelby Township, MI; Den, Ling [Sterling Heights, MI; Viola, Michael B [Macomb Township, MI; Lee, Jong-Hwan [Rochester Hills, MI
2011-08-30
A method and apparatus are described to selectively reduce NO.sub.x emissions of an internal combustion engine. An exhaust aftertreatment system includes an injection device operative to dispense a hydrocarbon reductant upstream of a silver-alumina catalytic reactor device. A control system determines a NO.sub.x concentration and hydrocarbon/NOx ratio based upon selected parameters of the exhaust gas feedstream and dispenses hydrocarbon reductant during lean engine operation. Included is a method to control elements of the feedstream during lean operation. The hydrocarbon reductant may include engine fuel.
SU-E-J-128: Two-Stage Atlas Selection in Multi-Atlas-Based Image Segmentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, T; Ruan, D
2015-06-15
Purpose: In the new era of big data, multi-atlas-based image segmentation is challenged by heterogeneous atlas quality and high computation burden from extensive atlas collection, demanding efficient identification of the most relevant atlases. This study aims to develop a two-stage atlas selection scheme to achieve computational economy with performance guarantee. Methods: We develop a low-cost fusion set selection scheme by introducing a preliminary selection to trim full atlas collection into an augmented subset, alleviating the need for extensive full-fledged registrations. More specifically, fusion set selection is performed in two successive steps: preliminary selection and refinement. An augmented subset is firstmore » roughly selected from the whole atlas collection with a simple registration scheme and the corresponding preliminary relevance metric; the augmented subset is further refined into the desired fusion set size, using full-fledged registration and the associated relevance metric. The main novelty of this work is the introduction of an inference model to relate the preliminary and refined relevance metrics, based on which the augmented subset size is rigorously derived to ensure the desired atlases survive the preliminary selection with high probability. Results: The performance and complexity of the proposed two-stage atlas selection method were assessed using a collection of 30 prostate MR images. It achieved comparable segmentation accuracy as the conventional one-stage method with full-fledged registration, but significantly reduced computation time to 1/3 (from 30.82 to 11.04 min per segmentation). Compared with alternative one-stage cost-saving approach, the proposed scheme yielded superior performance with mean and medium DSC of (0.83, 0.85) compared to (0.74, 0.78). Conclusion: This work has developed a model-guided two-stage atlas selection scheme to achieve significant cost reduction while guaranteeing high segmentation accuracy. The benefit in both complexity and performance is expected to be most pronounced with large-scale heterogeneous data.« less
Fluid technology (selected components, devices, and systems): A compilation
NASA Technical Reports Server (NTRS)
1974-01-01
Developments in fluid technology and hydraulic equipment are presented. The subjects considered are: (1) the use of fluids in the operation of switches, amplifiers, and servo devices, (2) devices and data for laboratory use in the study of fluid dynamics, and (3) the use of fluids as controls and certain methods of controlling fluids.
Skillman, Joanna; Thomas, Sunil
2011-12-01
When intermittent compression devices (ICDs) are used to prevent venous thromboembolism (VTE) they can cause pressure sores in a selected group of women, undergoing long operations. A prospective audit pre and post intervention showed a reduced risk with an alternative device, without increasing the risk of VTE.
The First NREL Conference on thermophotovoltaic generation of electricity: Proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-08-01
This collection of abstracts from the July 1994 meeting contains various information on thermophotovoltaic (TPV) conversion and converters. Discussed topics include: the current status of TPV conversion, TPV tutorials, heat source and emitter technologies, advanced TPV devices, selective emitter theory and practice, programmatic and systems issues, device fundamentals, and device and material characterization.
Radio controlled release apparatus for animal data acquisition devices
Stamps, James Frederick
2000-01-01
A novel apparatus for reliably and selectively releasing a data acquisition package from an animal for recovery. The data package comprises two parts: 1) an animal data acquisition device and 2) a co-located release apparatus. One embodiment, which is useful for land animals, the release apparatus includes two major components: 1) an electronics package, comprising a receiver; a decoder comparator, having at plurality of individually selectable codes; and an actuator circuit and 2) a release device, which can be a mechanical device, which acts to release the data package from the animal. To release a data package from a particular animal, a radio transmitter sends a coded signal which is decoded to determine if the code is valid for that animal data package. Having received a valid code, the release device is activated to release the data package from the animal for subsequent recovery. A second embodiment includes floatation means and is useful for releasing animal data acquisition devices attached to sea animals. This embodiment further provides for releasing a data package underwater by employing an acoustic signal.
3D printed fluidics with embedded analytic functionality for automated reaction optimisation
Capel, Andrew J; Wright, Andrew; Harding, Matthew J; Weaver, George W; Li, Yuqi; Harris, Russell A; Edmondson, Steve; Goodridge, Ruth D
2017-01-01
Additive manufacturing or ‘3D printing’ is being developed as a novel manufacturing process for the production of bespoke micro- and milliscale fluidic devices. When coupled with online monitoring and optimisation software, this offers an advanced, customised method for performing automated chemical synthesis. This paper reports the use of two additive manufacturing processes, stereolithography and selective laser melting, to create multifunctional fluidic devices with embedded reaction monitoring capability. The selectively laser melted parts are the first published examples of multifunctional 3D printed metal fluidic devices. These devices allow high temperature and pressure chemistry to be performed in solvent systems destructive to the majority of devices manufactured via stereolithography, polymer jetting and fused deposition modelling processes previously utilised for this application. These devices were integrated with commercially available flow chemistry, chromatographic and spectroscopic analysis equipment, allowing automated online and inline optimisation of the reaction medium. This set-up allowed the optimisation of two reactions, a ketone functional group interconversion and a fused polycyclic heterocycle formation, via spectroscopic and chromatographic analysis. PMID:28228852
NASA Astrophysics Data System (ADS)
Kim, Sung-Il; Kim, Jeongtae; Koo, Chiwan; Joung, Yeun-Ho; Choi, Jiyeon
2018-02-01
Microfluidics technology which deals with small liquid samples and reagents within micro-scale channels has been widely applied in various aspects of biological, chemical, and life-scientific research. For fabricating microfluidic devices, a silicon-based polymer, PDMS (Polydimethylsiloxane), is widely used in soft lithography, but it has several drawbacks for microfluidic applications. Glass has many advantages over PDMS due to its excellent optical, chemical, and mechanical properties. However, difficulties in fabrication of glass microfluidic devices that requires multiple skilled steps such as MEMS technology taking several hours to days, impedes broad application of glass based devices. Here, we demonstrate a rapid and optical prototyping of a glass microfluidic device by using femtosecond laser assisted selective etching (LASE) and femtosecond laser welding. A microfluidic droplet generator was fabricated as a demonstration of a microfluidic device using our proposed prototyping. The fabrication time of a single glass chip containing few centimeter long and complex-shaped microfluidic channels was drastically reduced in an hour with the proposed laser based rapid and simple glass micromachining and hermetic packaging technique.
Application-oriented offloading in heterogeneous networks for mobile cloud computing
NASA Astrophysics Data System (ADS)
Tseng, Fan-Hsun; Cho, Hsin-Hung; Chang, Kai-Di; Li, Jheng-Cong; Shih, Timothy K.
2018-04-01
Nowadays Internet applications have become more complicated that mobile device needs more computing resources for shorter execution time but it is restricted to limited battery capacity. Mobile cloud computing (MCC) is emerged to tackle the finite resource problem of mobile device. MCC offloads the tasks and jobs of mobile devices to cloud and fog environments by using offloading scheme. It is vital to MCC that which task should be offloaded and how to offload efficiently. In the paper, we formulate the offloading problem between mobile device and cloud data center and propose two algorithms based on application-oriented for minimum execution time, i.e. the Minimum Offloading Time for Mobile device (MOTM) algorithm and the Minimum Execution Time for Cloud data center (METC) algorithm. The MOTM algorithm minimizes offloading time by selecting appropriate offloading links based on application categories. The METC algorithm minimizes execution time in cloud data center by selecting virtual and physical machines with corresponding resource requirements of applications. Simulation results show that the proposed mechanism not only minimizes total execution time for mobile devices but also decreases their energy consumption.
Scheduled Peripheral Component Interconnect Arbiter
NASA Technical Reports Server (NTRS)
Nixon, Scott Alan (Inventor)
2015-01-01
Systems and methods are described for arbitrating access of a communication bus. In one embodiment, a method includes performing steps on one or more processors. The steps include: receiving an access request from a device of the communication bus; evaluating a bus schedule to determine an importance of the device based on the access request; and selectively granting access of the communication bus to the device based on the importance of the device.
Mauser, Stanislas; Burgert, Oliver
2014-01-01
There are several intra-operative use cases which require the surgeon to interact with medical devices. We used the Leap Motion Controller as input device and implemented two use-cases: 2D-Interaction (e.g. advancing EPR data) and selection of a value (e.g. room illumination brightness). The gesture detection was successful and we mapped its output to several devices and systems.
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Cohn, Lewis M.
2008-01-01
At an earlier conference we discussed a selection of the challenges for radiation testing of modern semiconductor devices focusing on state-of-the-art CMOS technologies. In this presentation, we extend this discussion focusing on the following areas: (1) Device packaging, (2) Evolving physical single even upset mechanisms, (3) Device complexity, and (4) the goal of understanding the limitations and interpretation of radiation testing results.
NASA Astrophysics Data System (ADS)
Peng, Wanli; Zhang, Yanchao; Yang, Zhimin; Chen, Jincan
2018-02-01
Three-terminal energy selective electron (ESE) devices consisting of three electronic reservoirs connected by two energy filters and an electronic conductor with negligible resistance may work as ESE refrigerators and amplifiers. They have three possible connective ways for the electronic conductor and six electronic transmission forms. The configuration of energy filters may be described by the different transmission functions such as the rectangular and Lorentz transmission functions. The ESE devices with three connective ways can be, respectively, regarded as three equivalent hybrid systems composed of an ESE heat engine and an ESE refrigerator/heat pump. With the help of the theory of the ESE devices operated between two electronic reservoirs, the coefficients of performance and cooling rates (heat-pumping rates) of hybrid systems are directly derived. The general performance characteristics of hybrid systems are revealed. The optimal regions of these devices are determined. The performances of the devices with three connective ways of the electronic conductor and two configurations of energy filters are compared in detail. The advantages and disadvantages of each of three-terminal ESE devices are expounded. The results obtained here may provide some guidance for the optimal design and operation of three-terminal ESE devices.
Verification of S&D Solutions for Network Communications and Devices
NASA Astrophysics Data System (ADS)
Rudolph, Carsten; Compagna, Luca; Carbone, Roberto; Muñoz, Antonio; Repp, Jürgen
This chapter describes the tool-supported verification of S&D Solutions on the level of network communications and devices. First, the general goals and challenges of verification in the context of AmI systems are highlighted and the role of verification and validation within the SERENITY processes is explained.Then, SERENITY extensions to the SH VErification tool are explained using small examples. Finally, the applicability of existing verification tools is discussed in the context of the AVISPA toolset. The two different tools show that for the security analysis of network and devices S&D Patterns relevant complementary approachesexist and can be used.
InP (Indium Phosphide): Into the future
NASA Technical Reports Server (NTRS)
Brandhorst, Henry W., Jr.
1989-01-01
Major industry is beginning to be devoted to indium phosphide and its potential applications. Key to these applications are high speed and radiation tolerance; however the high cost of indium phosphide may be an inhibitor to progress. The broad applicability of indium phosphide to many devices will be discussed with an emphasis on photovoltaics. Major attention is devoted to radiation tolerance and means of reducing cost of devices. Some of the approaches applicable to solar cells may also be relevant to other devices. The intent is to display the impact of visionary leadership in the field and enable the directions and broad applicability of indium phosphide.
Insight into carrier lifetime impact on band-modulation devices
NASA Astrophysics Data System (ADS)
Parihar, Mukta Singh; Lee, Kyung Hwa; Park, Hyung Jin; Lacord, Joris; Martinie, Sébastien; Barbé, Jean-Charles; Xu, Yue; El Dirani, Hassan; Taur, Yuan; Cristoloveanu, Sorin; Bawedin, Maryline
2018-05-01
A systematic study to model and characterize the band-modulation Z2-FET device is developed bringing light to the relevance of the carrier lifetime influence. This work provides guidelines to optimize the Z2-FETs for sharp switching, ESD protection, and 1T-DRAM applications. Lower carrier lifetime in the Z2-FET helps in attaining the sharp switch. We provide new insights into the correlation between generation/recombination, diffusion, electrostatic barriers and carrier lifetime.
Apparatus for and method of producing monodisperse submicron polymer powders from solution
Noid, Donald W.; Otaigbe, Joshua U.; Barnes, Michael D.; Sumpter, Bobby G.; Kung, Chung-Yi
2002-01-01
This invention describes a method of producing polymer powders from solution in a compatible solvent using a new device referred to as a microdroplets on demand generator (MODG). The embodiment of this invention is the MODG apparatus and its relevance as a method to extensive application in materials science and technology. Proof of concept is demonstrated using poly(ethylene) glycol polymer microparticles generated with the MODG and captured in a microparticle levitation device.
Evaluating candidate reactions to selection practices using organisational justice theory.
Patterson, Fiona; Zibarras, Lara; Carr, Victoria; Irish, Bill; Gregory, Simon
2011-03-01
This study aimed to examine candidate reactions to selection practices in postgraduate medical training using organisational justice theory. We carried out three independent cross-sectional studies using samples from three consecutive annual recruitment rounds. Data were gathered from candidates applying for entry into UK general practice (GP) training during 2007, 2008 and 2009. Participants completed an evaluation questionnaire immediately after the short-listing stage and after the selection centre (interview) stage. Participants were doctors applying for GP training in the UK. Main outcome measures were participants' evaluations of the selection methods and perceptions of the overall fairness of each selection stage (short-listing and selection centre). A total of 23,855 evaluation questionnaires were completed (6893 in 2007, 10,497 in 2008 and 6465 in 2009). Absolute levels of perceptions of fairness of all the selection methods at both the short-listing and selection centre stages were consistently high over the 3years. Similarly, all selection methods were considered to be job-related by candidates. However, in general, candidates considered the selection centre stage to be significantly fairer than the short-listing stage. Of all the selection methods, the simulated patient consultation completed at the selection centre stage was rated as the most job-relevant. This is the first study to use a model of organisational justice theory to evaluate candidate reactions during selection into postgraduate specialty training. The high-fidelity selection methods are consistently viewed as more job-relevant and fairer by candidates. This has important implications for the design of recruitment systems for all specialties and, potentially, for medical school admissions. Using this approach, recruiters can systematically compare perceptions of the fairness and job relevance of various selection methods. © Blackwell Publishing Ltd 2011.
NASA Astrophysics Data System (ADS)
Kuenzig, Thomas; Dehé, Alfons; Krumbein, Ulrich; Schrag, Gabriele
2018-05-01
Maxing out the technological limits in order to satisfy the customers’ demands and obtain the best performance of micro-devices and-systems is a challenge of today’s manufacturers. Dedicated system simulation is key to investigate the potential of device and system concepts in order to identify the best design w.r.t. the given requirements. We present a tailored, physics-based system-level modeling approach combining lumped with distributed models that provides detailed insight into the device and system operation at low computational expense. The resulting transparent, scalable (i.e. reusable) and modularly composed models explicitly contain the physical dependency on all relevant parameters, thus being well suited for dedicated investigation and optimization of MEMS devices and systems. This is demonstrated for an industrial capacitive silicon microphone. The performance of such microphones is determined by distributed effects like viscous damping and inhomogeneous capacitance variation across the membrane as well as by system-level phenomena like package-induced acoustic effects and the impact of the electronic circuitry for biasing and read-out. The here presented model covers all relevant figures of merit and, thus, enables to evaluate the optimization potential of silicon microphones towards high fidelity applications. This work was carried out at the Technical University of Munich, Chair for Physics of Electrotechnology. Thomas Kuenzig is now with Infineon Technologies AG, Neubiberg.
2009-02-15
Magnon scattered light generally experiences a 90° rotation in polarization from the incident beam. The wave- vector selective BLS measurements...filters, phase locked microwave pulse sources, microwave and millimeter wave devices such as isolators, circulators, phase shifters, secure signal...Wave vector selective Brillouin light scattering measurements and analysis, " C. L. Ordofiez-Romero, B. A. Kalinikos, P. Krivosik, Wei Tong, P
Cornil, J; Verlaak, S; Martinelli, N; Mityashin, A; Olivier, Y; Van Regemorter, T; D'Avino, G; Muccioli, L; Zannoni, C; Castet, F; Beljonne, D; Heremans, P
2013-02-19
The extraordinary semiconducting properties of conjugated organic materials continue to attract attention across disciplines including materials science, engineering, chemistry, and physics, particularly with application to organic electronics. Such materials are used as active components in light-emitting diodes, field-effect transistors, or photovoltaic cells, as a substitute for (mostly Si-based) inorganic semiconducting materials. Many strategies developed for inorganic semiconductor device building (doping, p-n junctions, etc.) have been attempted, often successfully, with organics, even though the key electronic and photophysical properties of organic thin films are fundamentally different from those of their bulk inorganic counterparts. In particular, organic materials consist of individual units (molecules or conjugated segments) that are coupled by weak intermolecular forces. The flexibility of organic synthesis has allowed the development of more efficient opto-electronic devices including impressive improvements in quantum yields for charge generation in organic solar cells and in light emission in electroluminescent displays. Nonetheless, a number of fundamental questions regarding the working principles of these devices remain that preclude their full optimization. For example, the role of intermolecular interactions in driving the geometric and electronic structures of solid-state conjugated materials, though ubiquitous in organic electronic devices, has long been overlooked, especially when it comes to these interfaces with other (in)organic materials or metals. Because they are soft and in most cases disordered, conjugated organic materials support localized electrons or holes associated with local geometric distortions, also known as polarons, as primary charge carriers. The spatial localization of excess charges in organics together with low dielectric constant (ε) entails very large electrostatic effects. It is therefore not obvious how these strongly interacting electron-hole pairs can potentially escape from their Coulomb well, a process that is at the heart of photoconversion or molecular doping. Yet they do, with near-quantitative yield in some cases. Limited screening by the low dielectric medium in organic materials leads to subtle static and dynamic electronic polarization effects that strongly impact the energy landscape for charges, which offers a rationale for this apparent inconsistency. In this Account, we use different theoretical approaches to predict the energy landscape of charge carriers at the molecular level and review a few case studies highlighting the role of electrostatic interactions in conjugated organic molecules. We describe the pros and cons of different theoretical approaches that provide access to the energy landscape defining the motion of charge carriers. We illustrate the applications of these approaches through selected examples involving OFETs, OLEDs, and solar cells. The three selected examples collectively show that energetic disorder governs device performances and highlights the relevance of theoretical tools to probe energy landscapes in molecular assemblies.
Shaw, Sally Jane
2017-07-12
There is a range of risk factors that can lead to peripheral intravenous (IV) cannula failure, and several failed cannulation attempts can result in the patient experiencing increased pain, discomfort and delays in receiving IV therapy. The Vessel Health and Preservation (VHP) framework is a tool that can be used to improve clinical decision-making and the patient experience in relation to vascular access and IV therapy. Use of the VHP framework can ensure the right vein and right vascular access device (VAD) is selected at the right time for each patient. This article describes how healthcare practitioners can use the VHP framework to support and enhance vein assessment and VAD selection. It outlines the various types of VAD available, focusing on short-term peripheral IV cannulae, which are the most commonly used devices. It also explores the potential benefits of implementing the VHP framework in clinical areas.
Modular hybrid plasma reactor and related systems and methods
Kong, Peter C.; Grandy, Jon D.; Detering, Brent A.
2010-06-22
A device, method and system for generating a plasma is disclosed wherein an electrical arc is established and the movement of the electrical arc is selectively controlled. In one example, modular units are coupled to one another to collectively define a chamber. Each modular unit may include an electrode and a cathode spaced apart and configured to generate an arc therebetween. A device, such as a magnetic or electromagnetic device, may be used to selectively control the movement of the arc about a longitudinal axis of the chamber. The arcs of individual modules may be individually controlled so as to exhibit similar or dissimilar motions about the longitudinal axis of the chamber. In another embodiment, an inlet structure may be used to selectively define the flow path of matter introduced into the chamber such that it travels in a substantially circular or helical path within the chamber.
Transient response of nonideal ion-selective microchannel-nanochannel devices
NASA Astrophysics Data System (ADS)
Leibowitz, Neta; Schiffbauer, Jarrod; Park, Sinwook; Yossifon, Gilad
2018-04-01
We report evidence of variation in ion selectivity of a fabricated microchannel-nanochannel device resulting in the appearance of a distinct local maximum in the overlimiting chronopotentiometric response. In this system consisting of shallow microchannels joined by a nanochannel, viscous shear at the microchannel walls suppresses the electro-osmotic instability and prevents any associated contribution to the nonmonotonic response. Thus, this response is primarily electrodiffusive. Numerical simulations indicate that concentration polarization develops not only within the microchannel but also within the nanochannel itself, with a local voltage maximum in the chronopotentiometric response correlated with interfacial depletion and having the classic i-2 Sands time dependence. Furthermore, the occurrence of the local maxima is correlated with the change in selectivity due to internal concentration polarization. Understanding the transient nonideal permselective response is essential for obtaining fundamental insight and for optimizing efficient operation of practical fabricated nanofluidic and membrane devices.
Venturini, Joseph M; Retzer, Elizabeth M; Estrada, J Raider; Mediratta, Anuj; Friant, Janet; Nathan, Sandeep; Paul, Jonathan D; Blair, John; Lang, Roberto M; Shah, Atman P
2016-10-01
Patent foramen ovale (PFO) has been linked to cryptogenic stroke, and closure has been reported to improve clinical outcomes. However, there are no clear guidelines to direct device sizing. This study sought to use patient characteristics and echocardiographic findings to create a prediction score for device sizing. This was a retrospective review of patients undergoing percutaneous PFO closure at our institution between July 2010 and December 2014. Demographic and clinical characteristics were recorded, and all pre- and intraprocedural echocardiography results were evaluated. Thirty-six patients underwent percutaneous PFO closure during the study period. All procedures were performed using an Amplatzer Septal Occluder "Cribriform" (ASOC) device in one of three disc diameters: 25, 30, or 35 mm. Closure was indicated for cryptogenic stroke/transient ischemic attack in 75% of cases. Every case (100%) was successful with durable shunt correction at the 6-month follow-up without complications of erosion or device embolization. The presence of atrial septal aneurysm (ASA) ( p = 0.027) and PFO tunnel length >10 mm ( p = 0.038) were independently associated with increased device size. A scoring system of 1 point for male sex, 1 point for ASA, and 1 point for PFO tunnel >10 mm long was associated with the size of closure device implanted ( p = 0.006). A simple scoring system may be used to select an optimally sized device for percutaneous PFO closure using the ASOC device.
Out with the old? The role of selective attention in retaining targets in partial report.
Lindsey, Dakota R B; Bundesen, Claus; Kyllingsbæk, Søren; Petersen, Anders; Logan, Gordon D
2017-01-01
In the partial-report task, subjects are asked to report only a portion of the items presented. Selective attention chooses which objects to represent in short-term memory (STM) on the basis of their relevance. Because STM is limited in capacity, one must sometimes choose which objects are removed from memory in light of new relevant information. We tested the hypothesis that the choices among newly presented information and old information in STM involve the same process-that both are acts of selective attention. We tested this hypothesis using a two-display partial-report procedure. In this procedure, subjects had to select and retain relevant letters (targets) from two sequentially presented displays. If selection in perception and retention in STM are the same process, then irrelevant letters (distractors) in the second display, which demanded attention because of their similarity to the targets, should have decreased target report from the first display. This effect was not obtained in any of four experiments. Thus, choosing objects to keep in STM is not the same process as choosing new objects to bring into STM.
Utility of biological sensor tags in animal conservation.
Wilson, A D M; Wikelski, M; Wilson, R P; Cooke, S J
2015-08-01
Electronic tags (both biotelemetry and biologging platforms) have informed conservation and resource management policy and practice by providing vital information on the spatial ecology of animals and their environments. However, the extent of the contribution of biological sensors (within electronic tags) that measure an animal's state (e.g., heart rate, body temperature, and details of locomotion and energetics) is less clear. A literature review revealed that, despite a growing number of commercially available state sensor tags and enormous application potential for such devices in animal biology, there are relatively few examples of their application to conservation. Existing applications fell under 4 main themes: quantifying disturbance (e.g., ecotourism, vehicular and aircraft traffic), examining the effects of environmental change (e.g., climate change), understanding the consequences of habitat use and selection, and estimating energy expenditure. We also identified several other ways in which sensor tags could benefit conservation, such as determining the potential efficacy of management interventions. With increasing sensor diversity of commercially available platforms, less invasive attachment techniques, smaller device sizes, and more researchers embracing such technology, we suggest that biological sensor tags be considered a part of the necessary toolbox for conservation. This approach can measure (in real time) the state of free-ranging animals and thus provide managers with objective, timely, relevant, and accurate data to inform policy and decision making. © 2015 Society for Conservation Biology.
Tang, Xiling; Remmel, Kurtis; Lan, Xinwei; Deng, Jiangdong; Xiao, Hai; Dong, Junhang
2009-09-15
Small size fiber optic devices integrated with chemically sensitive photonic materials are emerging as a new class of high-performance optical chemical sensor that have the potential to meet many analytical challenges in future clean energy systems and environmental management. Here, we report the integration of a proton conducting perovskite oxide thin film with a long-period fiber grating (LPFG) device for high-temperature in situ measurement of bulk hydrogen in fossil- and biomass-derived syngas. The perovskite-type Sr(Ce(0.8)Zr(0.1))Y(0.1)O(2.95) (SCZY) nanocrystalline thin film is coated on the 125 microm diameter LPFG by a facile polymeric precursor route. This fiber optic sensor (FOS) operates by monitoring the LPFG resonant wavelength (lambda(R)), which is a function of the refractive index of the perovskite oxide overcoat. At high temperature, the types and population of the ionic and electronic defects in the SCZY structure depend on the surrounding hydrogen partial pressure. Thus, varying the H(2) concentration changes the SCZY film refractive index and light absorbing characteristics that in turn shifts the lambda(R) of the LPFG. The SCZY-coated LPFG sensor has been demonstrated for bulk hydrogen measurement at 500 degrees C for its sensitivity, stability/reversibility, and H(2)-selectivity over other relevant small gases including CO, CH(4), CO(2), H(2)O, and H(2)S, etc.
Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad; Notarianni, Christina; Nanda, Anil
2018-06-01
Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI. Copyright © 2018 Elsevier Inc. All rights reserved.
Recent progress in printed 2/3D electronic devices
NASA Astrophysics Data System (ADS)
Klug, Andreas; Patter, Paul; Popovic, Karl; Blümel, Alexander; Sax, Stefan; Lenz, Martin; Glushko, Oleksandr; Cordill, Megan J.; List-Kratochvil, Emil J. W.
2015-09-01
New, energy-saving, efficient and cost-effective processing technologies such as 2D and 3D inkjet printing (IJP) for the production and integration of intelligent components will be opening up very interesting possibilities for industrial applications of molecular materials in the near future. Beyond the use of home and office based printers, "inkjet printing technology" allows for the additive structured deposition of photonic and electronic materials on a wide variety of substrates such as textiles, plastics, wood, stone, tiles or cardboard. Great interest also exists in applying IJP in industrial manufacturing such as the manufacturing of PCBs, of solar cells, printed organic electronics and medical products. In all these cases inkjet printing is a flexible (digital), additive, selective and cost-efficient material deposition method. Due to these advantages, there is the prospect that currently used standard patterning processes can be replaced through this innovative material deposition technique. A main issue in this research area is the formulation of novel functional inks or the adaptation of commercially available inks for specific industrial applications and/or processes. In this contribution we report on the design, realization and characterization of novel active and passive inkjet printed electronic devices including circuitry and sensors based on metal nanoparticle ink formulations and the heterogeneous integration into 2/3D printed demonstrators. The main emphasis of this paper will be on how to convert scientific inkjet knowledge into industrially relevant processes and applications.
In-flight calibration of SCIAMACHY's polarization sensitivity
NASA Astrophysics Data System (ADS)
Liebing, Patricia; Krijger, Matthijs; Snel, Ralph; Bramstedt, Klaus; Noël, Stefan; Bovensmann, Heinrich; Burrows, John P.
2018-01-01
This paper describes the in-flight calibration of the polarization response of the SCIAMACHY polarization measurement devices (PMDs) and a selected region of its science channels. With the lack of polarized calibration sources it is not possible to obtain such a calibration from dedicated calibration measurements. Instead, the earthshine itself, together with a simplified radiative transfer model (RTM), is used to derive time-dependent and measurement-configuration-dependent polarization sensitivities. The results are compared to an instrument model that describes the degradation of the instrument as a result of a slow buildup of contaminant layers on its elevation and azimuth scan mirrors. This comparison reveals significant differences between the model prediction and the data, suggesting an unforeseen change between on-ground and in-flight calibration in at least one of the polarization-sensitive components of the optical bench. The possibility of mechanisms other than scan mirror contamination contributing to the degradation of the instrument will be discussed. The data are consistent with a polarization phase shift occurring in the beam split prism used to divert the light coming from the telescope to the different channels and polarization measurement devices. The extension of the instrument degradation model with a linear retarder enables the determination of the relevant parameters to describe this phase shift and ultimately results in a significant improvement of the polarization measurements as well as the polarization response correction of measured radiances.
A charge-based model of Junction Barrier Schottky rectifiers
NASA Astrophysics Data System (ADS)
Latorre-Rey, Alvaro D.; Mudholkar, Mihir; Quddus, Mohammed T.; Salih, Ali
2018-06-01
A new charge-based model of the electric field distribution for Junction Barrier Schottky (JBS) diodes is presented, based on the description of the charge-sharing effect between the vertical Schottky junction and the lateral pn-junctions that constitute the active cell of the device. In our model, the inherently 2-D problem is transformed into a simple but accurate 1-D problem which has a closed analytical solution that captures the reshaping and reduction of the electric field profile responsible for the improved electrical performance of these devices, while preserving physically meaningful expressions that depend on relevant device parameters. The validation of the model is performed by comparing calculated electric field profiles with drift-diffusion simulations of a JBS device showing good agreement. Even though other fully 2-D models already available provide higher accuracy, they lack physical insight making the proposed model an useful tool for device design.
Wearable ear EEG for brain interfacing
NASA Astrophysics Data System (ADS)
Schroeder, Eric D.; Walker, Nicholas; Danko, Amanda S.
2017-02-01
Brain-computer interfaces (BCIs) measuring electrical activity via electroencephalogram (EEG) have evolved beyond clinical applications to become wireless consumer products. Typically marketed for meditation and neu- rotherapy, these devices are limited in scope and currently too obtrusive to be a ubiquitous wearable. Stemming from recent advancements made in hearing aid technology, wearables have been shrinking to the point that the necessary sensors, circuitry, and batteries can be fit into a small in-ear wearable device. In this work, an ear-EEG device is created with a novel system for artifact removal and signal interpretation. The small, compact, cost-effective, and discreet device is demonstrated against existing consumer electronics in this space for its signal quality, comfort, and usability. A custom mobile application is developed to process raw EEG from each device and display interpreted data to the user. Artifact removal and signal classification is accomplished via a combination of support matrix machines (SMMs) and soft thresholding of relevant statistical properties.
Consumer sleep monitors: is there a baby in the bathwater?
Russo, Kathryn; Goparaju, Balaji; Bianchi, Matt T
2015-01-01
The rapid expansion of consumer sleep devices is outpacing the validation data necessary to assess the potential use of these devices in clinical and research settings. Common sleep monitoring devices utilize a variety of sensors to track movement as well as cardiac and respiratory physiology. The variety of sensors and user-specific factors offer the potential, at least theoretically, for clinically relevant information. We describe the current challenges for interpretation of consumer sleep monitoring data, since the devices are mainly used in non-medical contexts (consumer use) although medically-definable sleep disorders may commonly occur in this setting. A framework for addressing questions of how certain devices might be useful is offered. We suggest that multistage validation efforts are crucially needed, from the level of sensor data and algorithm output, to extrapolations beyond healthy adults and into other populations and real-world environments. PMID:26604847
Signal Enhancement and Suppression During Visual-Spatial Selective Attention
Couperus, J. W.; Mangun, G.R.
2010-01-01
Selective attention involves the relative enhancement of relevant versus irrelevant stimuli. However, whether this relative enhancement involves primarily enhancement of attended stimuli, or suppression of irrelevant stimuli, remains controversial. Moreover, if both enhancement and suppression are involved, whether they result from a single mechanism or separate mechanisms during attentional control or selection is not known. In two experiments using a spatial cuing paradigm with task-relevant targets and irrelevant distractors, target and distracter processing was examined as a function of distractor expectancy. Additionally, in the second study the interaction of perceptual load and distractor expectancy was explored. In both experiments, distractors were either validly cued (70%) or invalidly cued (30%) in order to examine the effects of distractor expectancy on attentional control as well as target and distractor processing. The effects of distractor expectancy were assessed using event-related potentials recorded during the cue-to-target period (preparatory attention) and in response to the task-relevant target stimuli (selective stimulus processing). Analyses of distractor-present displays (anticipated versus unanticipated), showed modulations in brain activity during both the preparatory period and during target processing. The pattern of brain responses suggest both facilitation of attended targets and suppression of unattended distractors. These findings provide evidence for a two-process model of visual spatial selective attention, where one mechanism (facilitation) influences relevant stimuli and another (suppression) acts to filter distracting stimuli. PMID:20807513
Incident reporting to BfArM - regulatory framework, results and challenges.
Seidel, Robin; Stößlein, Ekkehard; Lauer, Wolfgang
2016-04-01
Medical devices are manifold and one of the most innovative fields of technology. As technologies advance, former limits cease to exist and complex devices become reality. Medical devices represent a very dynamic field with high economic relevance. The manufacturer of a medical device is obliged to minimize product-related risks as well as to demonstrate compliance with the so-called "essential requirements" regarding safety and performance before placing the device on the market. Any critical incident in relation to the application of a medical device has to be reported to the competent authority for risk assessment, which in Germany is either the Federal Institute for Drugs and Medical Devices (BfArM) or the Paul Ehrlich Institute (PEI) depending on the type of device. In this article, the German regulatory framework for medical devices and the resulting tasks for BfArM are described as well as the topics of its recently installed research and development group on prospective risk identification and application safety for medical devices. Results of failure mode and root cause analyses of incident data are presented as well as further data on cases with the result "root-cause analysis not possible". Finally an outlook is given on future challenges regarding risk assessment for medical devices.
Osiurak, François; Granjon, Marine; Bonnevie, Isabelle; Brogniart, Joël; Mechtouff, Laura; Benoit, Amandine; Nighoghossian, Norbert; Lesourd, Mathieu
2018-05-01
Recent evidence indicates that some left brain-damaged (LBD) patients have difficulties to use familiar tools because of the inability to reason about physical object properties. A fundamental issue is to understand the residual capacity of those LBD patients in tool selection. Three LBD patients with tool use disorders, three right brain-damaged (RBD) patients, and six matched healthy controls performed a novel tool selection task, consisting in extracting a target out from a box by selecting the relevant tool among eight, four, or two tools. Three criteria were manipulated to make relevant and irrelevant tools (size, rigidity, shape). LBD patients selected a greater number of irrelevant tools and had more difficulties to solve the task compared to RBD patients and controls. All participants committed more errors for selecting relevant tools based on rigidity and shape than size. In some LBD patients, the difficulties persisted even in the 2-Choice condition. Our findings confirm that tool use disorders result from impaired technical reasoning, leading patients to meet difficulties in selecting tools based on their physical properties. We also go further by showing that these difficulties can decrease as the choice is reduced, at least for some properties, opening new avenues for rehabilitation programs. (JINS, 2018, 24, 524-529).
NASA Astrophysics Data System (ADS)
Agjee, Na'eem Hoosen; Ismail, Riyad; Mutanga, Onisimo
2016-10-01
Water hyacinth plants (Eichhornia crassipes) are threatening freshwater ecosystems throughout Africa. The Neochetina spp. weevils are seen as an effective solution that can combat the proliferation of the invasive alien plant. We aimed to determine if multitemporal hyperspectral data could be utilized to detect the efficacy of the biocontrol agent. The random forest (RF) algorithm was used to classify variable infestation levels for 6 weeks using: (1) all the hyperspectral bands, (2) bands selected by the recursive feature elimination (RFE) algorithm, and (3) bands selected by the Boruta algorithm. Results showed that the RF model using all the bands successfully produced low-classification errors (12.50% to 32.29%) for all 6 weeks. However, the RF model using Boruta selected bands produced lower classification errors (8.33% to 15.62%) than the RF model using all the bands or bands selected by the RFE algorithm (11.25% to 21.25%) for all 6 weeks, highlighting the utility of Boruta as an all relevant band selection algorithm. All relevant bands selected by Boruta included: 352, 754, 770, 771, 775, 781, 782, 783, 786, and 789 nm. It was concluded that RF coupled with Boruta band-selection algorithm can be utilized to undertake multitemporal monitoring of variable infestation levels on water hyacinth plants.
High energy devices versus low energy devices in orthopedics treatment modalities
NASA Astrophysics Data System (ADS)
Schultheiss, Reiner
2003-10-01
The orthopedic consensus group defined in 1997 the 42 most likely relevant parameters of orthopedic shock wave devices. The idea of this approach was to correlate the different clinical outcomes with the physical properties of the different devices with respect to their acoustical waves. Several changes in the hypothesis of the dose effect relationship have been noticed since the first orthopedic treatments. The relation started with the maximum pressure p+, followed by the total energy, the energy density; and finally the single treatment approach using high, and then the multiple treatment method using low energy. Motivated by the reimbursement situation in Germany some manufacturers began to redefine high and low energy devices independent of the treatment modality. The OssaTron as a high energy, single treatment electro hydraulic device gained FDA approval as the first orthopedic ESWT device for plantar fasciitis and, more recently, for lateral epicondylitis. Two low energy devices have now also gained FDA approval based upon a single treatment. Comparing the acoustic data, differences between the OssaTron and the other devices are obvious and will be elaborated upon. Cluster analysis of the outcomes and the acoustical data are presented and new concepts will be suggested.
Protein Complex Production from the Drug Discovery Standpoint.
Moarefi, Ismail
2016-01-01
Small molecule drug discovery critically depends on the availability of meaningful in vitro assays to guide medicinal chemistry programs that are aimed at optimizing drug potency and selectivity. As it becomes increasingly evident, most disease relevant drug targets do not act as a single protein. In the body, they are instead generally found in complex with protein cofactors that are highly relevant for their correct function and regulation. This review highlights selected examples of the increasing trend to use biologically relevant protein complexes for rational drug discovery to reduce costly late phase attritions due to lack of efficacy or toxicity.
Löf, Marie; Henriksson, Hanna; Forsum, Elisabet
2013-01-01
Activity energy expenditure (AEE) during free-living conditions can be assessed using devices based on different principles. To make proper comparisons of different devices' capacities to assess AEE, they should be evaluated in the same population. Thus, in the present study we evaluated, in the same group of subjects, the ability of three devices to assess AEE in groups and individuals during free-living conditions. In twenty women, AEE was assessed using RT3 (three-axial accelerometry) (AEERT3), Actiheart (a combination of heart rate and accelerometry) (AEEActi) and IDEEA (a multi-accelerometer system) (AEEIDEEA). Reference AEE (AEEref) was assessed using the doubly labelled water method and indirect calorimetry. Average AEEActi was 5760 kJ per 24 h and not significantly different from AEEref (5020 kJ per 24 h). On average, AEERT3 and AEEIDEEA were 2010 and 1750 kJ per 24 h lower than AEEref, respectively (P < 0·001). The limits of agreement (± 2 sd) were 2940 (Actiheart), 1820 (RT3) and 2650 (IDEEA) kJ per 24 h. The variance for AEERT3 was lower than for AEEActi (P = 0·006). The RT3 classified 60 % of the women in the correct activity category while the corresponding value for IDEEA and Actiheart was 30 %. In conclusion, the Actiheart may be useful for groups and the RT3 for individuals while the IDEEA requires further development. The results are likely to be relevant for a large proportion of Western women of reproductive age and demonstrate that the procedure selected to assess physical activity can greatly influence the possibilities to uncover important aspects regarding interactions between physical activity, diet and health.
Ripat, Jacquie; Verdonck, Michele; Carter, Roger Jaffrey
2018-04-01
To synthesize qualitative study findings on the meaning ascribed to wheelchairs and wheeled mobility devices (WMD) by WMD users. Bibliographic databases were systematically searched up to January 2015 to identify relevant papers. Reviewers selected studies, assessed methodological quality and thematically synthesized findings using a metasynthesis process described by Thomas and Harden (2008). Twenty articles were included. Four descriptive themes emerged: physical environment interaction; sociocultural experiences; participation in activities and occupations; and WMD-self relationship. WMD use was found to be a complex experience that can fluctuate through interaction with aspects of the environment and opportunities for participation. The analytic theme, dynamic duality of WMD experience, addressed the simultaneous enabling and disabling aspects of WMD use. Metasyntheses enable researchers to gain a deeper understanding of issues by examining findings across studies. Findings of this study provide a framework for understanding the complexity of WMD use. The framework has practical applications for clinicians and users of WMD in understanding the experience of WMD to be neither singular nor static. Implications for Rehabilitation The meaning of wheeled mobility device (WMD) use is dynamically influenced by the environment and opportunities afforded for occupational and social participation. A duality of experiences can emerge for WMD users, where wheeled mobility use can be at the same time positive and negative, based on the interaction with the environment. Clinicians need to determine the meaning that each individual user ascribes to the WMD, and to consider how that meaning may change over time. By understanding the meaning ascribed to WMD use by individuals, clinicians can be better prepared to work with the WMD users to address negative reinforcers of the experience in physical and sociocultural environments as well as highlighting the positive experiences.
Ennion, Liezel; Johannesson, Anton; Rhoda, Anthea
2017-10-01
Challenges exist with the provision of appropriate mobility assistive devices in rural areas. The use of the direct manufacturing prosthetic socket system is a possible solution to these challenges. The objective of this study was to test and explore the clients' perspectives with the application of this device. Within a mixed-methods approach, a longitudinal sequential explanatory design was applied. The Orthotic and Prosthetic User's Survey was administered to explore the use of the direct manufacturing prosthetic socket system in terms of function, health-related quality of life and client satisfaction. A conveniently selected sample of 21 individuals who suffered a unilateral trans-tibial amputation was included. Data were collected at 1, 3 and 6 months post fitting, and two focus group discussions were also administered. Of the 21 participants recruited, 11 returned for follow up. Although participants reported favourably about the prosthesis, their scores were generally worse than the norms with regard to function and quality of life. Participants highlighted the need for improvement in the cosmetic appearance of the prosthesis. The direct manufacturing prosthetic socket system could be considered as an alternative technique of socket manufacturing for individuals living in rural areas due to the shorter manufacture time and promising initial results, but further research on this topic with a bigger sample is recommended. Clinical relevance The direct manufacturing prosthetic socket system may be considered as an alternative to the traditional prosthetic socket manufacturing technique used in South Africa. As this device requires only one visit and therefore decreased travel by the patients to the hospitals, it could be applicable to more amputees who cannot return to hospital post discharge.