Cheng, Tonglei; Usaki, Ryo; Duan, Zhongchao; Gao, Weiqing; Deng, Dinghuan; Liao, Meisong; Kanou, Yasuhire; Matsumoto, Morio; Misumi, Takashi; Suzuki, Takenobu; Ohishi, Yasutake
2014-02-24
Soliton self-frequency shift (SSFS) and third-harmonic generation (THG) are observed in a four-hole As2S5 chalcogenide microstructured optical fiber (MOF). The As2S5 MOF is tapered to offer an ideal environment for SSFS. After tapering, the zero-dispersion wavelength (ZDW) shifts from 2.02 to 1.61 μm, and the rate of SSFS can be enhanced by increasing the energy density of the pulse. By varying the average input power from 220 to 340 mW, SSFS of a soliton central wavelength from 2.206 to 2.600 μm in the mid-infrared is observed in the tapered segment, and THG at 632 nm is observed in the untapered segment.
Soliton self-frequency shift controlled by a weak seed laser in tellurite photonic crystal fibers.
Liu, Lai; Meng, Xiangwei; Yin, Feixiang; Liao, Meisong; Zhao, Dan; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping
2013-08-01
We report the first demonstration of soliton self-frequency shift (SSFS) controlled by a weak continuous-wave (CW) laser, from a tellurite photonic crystal fiber pumped by a 1560 nm femtosecond fiber laser. The control of SSFS is performed by the cross-gain modulation of the 1560 nm femtosecond laser. By varying the input power of the weak CW laser (1560 nm) from 0 to 1.17 mW, the soliton generated in the tellurite photonic crystal fiber blue shifts from 1935 to 1591 nm. The dependence of the soliton wavelength on the operation wavelength of the weak CW laser is also measured. The results show the CW laser with a wavelength tunable range of 1530-1592 nm can be used to control the SSFS generation.
Self-frequency shift of dark solitons in optical fibers
NASA Astrophysics Data System (ADS)
Uzunov, Ivan M.; Gerdjikov, Vladimir S.
1993-02-01
An analytical description of the soliton self-frequency shift (SSFS) of dark solitons is presented, using the conservation laws of the nonlinear Schrödinger equation. It is shown that the influence of intrapulse Raman scattering on dark solitons crucially depends on the sign of soliton's velocity. Our analytical expressions qualitatively explain the main features of the SSFS of the dark solitons observed recently both in experiment [A. M. Weiner, R. N. Thurston, W. J. Tomlinson, J. P. Heritage, D. E. Leaird, E. M. Kirschner, and R. J. Hawkins, Opt. Lett. 14, 868 (1989)] and in numerical simulation [A. M. Weiner, R. N. Thurston, W. J. Tomlinson, J. P. Heritage, D. E. Leaird, E. M. Kirschner, and R. J. Hawkins, Opt. Lett. 14, 868 (1989); Yu. S. Kivshar and V. V. Afanasjev, ibid. 16, 285 (1991)].
NASA Astrophysics Data System (ADS)
Zhang, Xuyan; Zhang, Zhiyao; Wang, Shubing; Liang, Dong; Li, Heping; Liu, Yong
2018-03-01
We propose and demonstrate an approach that can achieve high-resolution quantization by employing soliton self-frequency shift and spectral compression. Our approach is based on a bi-directional comb-fiber architecture which is composed of a Sagnac-loop-based mirror and a comb-like combination of N sections of interleaved single-mode fibers and high nonlinear fibers. The Sagnac-loop-based mirror placed at the terminal of a bus line reflects the optical pulses back to the bus line to achieve additional N-stage spectral compression, thus single-stage soliton self-frequency shift (SSFS) and (2 N - 1)-stage spectral compression are realized in the bi-directional scheme. The fiber length in the architecture is numerically optimized, and the proposed quantization scheme is evaluated by both simulation and experiment in the case of N = 2. In the experiment, a quantization resolution of 6.2 bits is obtained, which is 1.2-bit higher than that of its uni-directional counterpart.
Human neuromagnetic steady-state responses to amplitude-modulated tones, speech, and music.
Lamminmäki, Satu; Parkkonen, Lauri; Hari, Riitta
2014-01-01
Auditory steady-state responses that can be elicited by various periodic sounds inform about subcortical and early cortical auditory processing. Steady-state responses to amplitude-modulated pure tones have been used to scrutinize binaural interaction by frequency-tagging the two ears' inputs at different frequencies. Unlike pure tones, speech and music are physically very complex, as they include many frequency components, pauses, and large temporal variations. To examine the utility of magnetoencephalographic (MEG) steady-state fields (SSFs) in the study of early cortical processing of complex natural sounds, the authors tested the extent to which amplitude-modulated speech and music can elicit reliable SSFs. MEG responses were recorded to 90-s-long binaural tones, speech, and music, amplitude-modulated at 41.1 Hz at four different depths (25, 50, 75, and 100%). The subjects were 11 healthy, normal-hearing adults. MEG signals were averaged in phase with the modulation frequency, and the sources of the resulting SSFs were modeled by current dipoles. After the MEG recording, intelligibility of the speech, musical quality of the music stimuli, naturalness of music and speech stimuli, and the perceived deterioration caused by the modulation were evaluated on visual analog scales. The perceived quality of the stimuli decreased as a function of increasing modulation depth, more strongly for music than speech; yet, all subjects considered the speech intelligible even at the 100% modulation. SSFs were the strongest to tones and the weakest to speech stimuli; the amplitudes increased with increasing modulation depth for all stimuli. SSFs to tones were reliably detectable at all modulation depths (in all subjects in the right hemisphere, in 9 subjects in the left hemisphere) and to music stimuli at 50 to 100% depths, whereas speech usually elicited clear SSFs only at 100% depth.The hemispheric balance of SSFs was toward the right hemisphere for tones and speech, whereas SSFs to music showed no lateralization. In addition, the right lateralization of SSFs to the speech stimuli decreased with decreasing modulation depth. The results showed that SSFs can be reliably measured to amplitude-modulated natural sounds, with slightly different hemispheric lateralization for different carrier sounds. With speech stimuli, modulation at 100% depth is required, whereas for music the 75% or even 50% modulation depths provide a reasonable compromise between the signal-to-noise ratio of SSFs and sound quality or perceptual requirements. SSF recordings thus seem feasible for assessing the early cortical processing of natural sounds.
Automated detection of secondary slip fronts in Cascadia
NASA Astrophysics Data System (ADS)
Bletery, Q.; Thomas, A.; Krogstad, R. D.; Hawthorne, J. C.; Skarbek, R. M.; Rempel, A. W.; Bostock, M. G.
2016-12-01
Slow slip events (SSEs) in subduction zones propagate along the plate interface at velocities on the order of 5 km/day and are largely confined to the region known as the transition zone, located down-dip of the seismogenically locked zone. As SSEs propagate, small on-fault asperities capable of generating seismic radiation fail in earthquake-like events known as low-frequency earthquakes. Recently, low-frequency earthquakes have been used to image smaller scale secondary slip fronts (SSFs) that occur within the actively slipping region of the fault after the main front associated with the SSE has passed. SSFs appear to occur over several different length and timescales and propagate both along dip and along strike. To date, most studies that have documented SSFs have relied on subjective methods, such as visual selection, to identify them. While such approaches have met with considerable success, it is likely that many small-scale fronts remain unidentifiable by visual inspection alone. We implement an algorithm to automatically detect SSFs from 2009 to 2015 along the Cascadia subduction zone. We also apply our algorithm to three large SSEs that were detected by campaign seismic instrumentation in the Vancouver Island area between 2003 and 2005. We find numerous SSFs at different time scales (from 30 min to 32 h duration). We provide a catalog of 1076 SSFs in Cascadia, including time, location, duration, area, propagation velocity, moment, stress drop, slip, slip velocity, and fracture energy for each of the detected SSFs. Analysis of their basic features indicate a wide spectra of stress drops, slip velocities, and fracture energy, as well as an intriguing relationship between SSF direction and duration that could potentially help discriminate between the different physical models proposed to explain slow slip phenomena.
Yin, Ke; Zhu, Rongzhen; Zhang, Bin; Jiang, Tian; Chen, Shengping; Hou, Jing
2016-09-05
Fiber based supercontinuum (SC) sources with output spectra covering the infrared atmospheric window are very useful in long-range atmospheric applications. It is proven that silica fibers can support the generation of broadband SC sources ranging from the visible to the short-wave infrared region. In this paper, we present the generation of an ultrahigh-brightness spectrally-flat 2-2.5 μm SC source in a cladding pumped thulium-doped fiber amplifier (TDFA) numerically and experimentally. The underlying physical mechanisms behind the SC generation process are investigated firstly with a numerical model which includes the fiber gain and loss, the dispersive and nonlinear effects. Simulation results show that abundant soliton pulses are generated in the TDFA, and they are shifted towards the long wavelength side very quickly with the nonlinearity of Raman soliton self-frequency shift (SSFS), and eventually the Raman SSFS process is halted due to the silica fiber's infrared loss. A spectrally-flat 2-2.5 μm SC source could be generated as the result of the spectral superposition of these abundant soliton pulses. These simulation results correspond qualitatively well to the following experimental results. Then, in the experiment, a cladding pumped large-mode-area TDFA is built for pursuing a high-power 2-2.5 μm SC source. By enhancing the pump strength, the output SC spectrum broadens to the long wavelength side gradually. At the highest pump power, the obtained SC source has a maximum average power of 203.4 W with a power conversion efficiency of 38.7%. It has a 3 dB spectral bandwidth of 545 nm ranging from 1990 to 2535 nm, indicating a power spectral density in excess of 370 mW/nm. Meanwhile, the output SC source has a good beam profile. This SC source, to the best of our knowledge, is the brightest spectrally-flat 2-2.5 μm light source ever reported. It will be highly desirable in a lot of long-range atmospheric applications, such as broad-spectrum LIDAR, free space communication and hyper-spectral imaging.
NASA Technical Reports Server (NTRS)
Williams, F. E.; Lemon, R. S.
1974-01-01
The engineering equations and mathematical models developed for use in the space shuttle functional simulator (SSFS) are presented, and include extensive revisions and additions to earlier documentation. Definitions of coordinate systems used by the SSFS models and coordinate tranformations are given, along with documentation of the flexible body mathematical models. The models were incorporated in the SSFS and are in the checkout stage.
Applications of step-selection functions in ecology and conservation.
Thurfjell, Henrik; Ciuti, Simone; Boyce, Mark S
2014-01-01
Recent progress in positioning technology facilitates the collection of massive amounts of sequential spatial data on animals. This has led to new opportunities and challenges when investigating animal movement behaviour and habitat selection. Tools like Step Selection Functions (SSFs) are relatively new powerful models for studying resource selection by animals moving through the landscape. SSFs compare environmental attributes of observed steps (the linear segment between two consecutive observations of position) with alternative random steps taken from the same starting point. SSFs have been used to study habitat selection, human-wildlife interactions, movement corridors, and dispersal behaviours in animals. SSFs also have the potential to depict resource selection at multiple spatial and temporal scales. There are several aspects of SSFs where consensus has not yet been reached such as how to analyse the data, when to consider habitat covariates along linear paths between observations rather than at their endpoints, how many random steps should be considered to measure availability, and how to account for individual variation. In this review we aim to address all these issues, as well as to highlight weak features of this modelling approach that should be developed by further research. Finally, we suggest that SSFs could be integrated with state-space models to classify behavioural states when estimating SSFs.
NASA Astrophysics Data System (ADS)
Okada, Aoi; Nishio, Johji; Iijima, Ryosuke; Ota, Chiharu; Goryu, Akihiro; Miyazato, Masaki; Ryo, Mina; Shinohe, Takashi; Miyajima, Masaaki; Kato, Tomohisa; Yonezawa, Yoshiyuki; Okumura, Hajime
2018-06-01
To investigate the mechanism of contraction/expansion behavior of Shockley stacking faults (SSFs) in 4H-SiC p–i–n diodes, the dependences of the SSF behavior on temperature and injection current density were investigated by electroluminescence image observation. We investigated the dependences of both triangle- and bar-shaped SSFs on the injection current density at four temperature levels. All SSFs in this study show similar temperature and injection current density dependences. We found that the expansion of SSFs at a high current density was converted to contraction at a certain value as the current decreased and that the value is temperature-dependent. It has been confirmed that SSF behavior, which was considered complex or peculiar, might be explained mainly by the energy change caused by SSFs.
NASA Astrophysics Data System (ADS)
Yamashita, T.; Hayashi, S.; Naijo, T.; Momose, K.; Osawa, H.; Senzaki, J.; Kojima, K.; Kato, T.; Okumura, H.
2018-05-01
Double Shockley-type stacking faults (2SSFs) formed in 4H-SiC epitaxial films with a dopant concentration of 1.0 × 1016 cm-3 were characterized using grazing incident X-ray topography and high-resolution scanning transmission electron microscopy. The origins of 2SSFs were investigated, and it was found that 2SSFs in the epitaxial layer originated from narrow SFs with a double Shockley structure in the substrate. Partial dislocations formed between 4H-type and 2SSF were also characterized. The shapes of 2SSFs are related with Burgers vectors and core types of the two Shockley partial dislocations.
Sinking skin flap syndrome and paradoxical herniation secondary to lumbar drainage.
Zhao, Jinchuan; Li, Guichen; Zhang, Yang; Zhu, Xiaobo; Hou, Kun
2015-06-01
Decompressive craniectomy (DC) has been regaining popularity in the field of neurosurgery because it can alleviate intracranial hypertension and brain swelling. Lumbar drainage (LD) is affective in managing numerous neurosurgical circumstances such as aneurysmal subarachnoid hemorrhage, refractory intracranial hypertension, cerebrospinal fluid (CSF) leakage and intraoperative brain relaxation. Sinking skin flap syndrome (SSFS) or paradoxical herniation (PH) is a rare complication and sporadically occurs in patients after DC. Hereby, we report for the first time that DC patients with LD can progress to SSFS or PH. We also evaluated the risk factors for the incidence of SSFS in DC patients with LD. We retrospectively assessed 37 patients who underwent DC and LD for cerebrovascular diseases from the First Hospital of Jilin University between January, 2007 and December, 2012. Nine (4 male and 5 female) of 37 patients experienced SSFS or PH following LD. At the last follow-up (mean 9 months, range 6-12 months), eight patients recovered completely due to timely conservative management and one patient died from PH. The mortality rate was 11% (1/9) from the complications of PH or SSFS. Further statistical analysis revealed that mean daily CSF volume was a risk factor for the incidence of SSFS in DC patients with LD. SSFS or PH can be identified in DC patients following LD. Patients that undergo DC and LD should be monitored more intensively. Most patients can completely recover with timely conservative management, bed rest, Trendelenburg position, sufficient intravenous fluid, and temporary clipping of the catheter. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Yosep; Choi, Junhyun; Tong, Meiping, E-mail: tongmeiping@iee.pku.edu.cn
2014-04-01
Millimeter-sized spherical silica foams (SSFs) with hierarchical multi-modal pore structure featuring high specific surface area and ordered mesoporous frameworks were successfully prepared using aqueous agar addition, foaming and drop-in-oil processes. The pore-related properties of the prepared spherical silica (SSs) and SSFs were systematically characterized by field emission-scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), small-angle X-ray diffraction (SAXRD), Hg intrusion porosimetry, and N{sub 2} adsorption–desorption isotherm measurements. Improvements in the BET surface area and total pore volume were observed at 504 m{sup 2} g{sup −1} and 5.45 cm{sup 3} g{sup −1}, respectively, after an agar addition and foaming process. Despitemore » the increase in the BET surface area, the mesopore wall thickness and the pore size of the mesopores generated from the block copolymer with agar addition were unchanged based on the SAXRD, TEM, and BJH methods. The SSFs prepared in the present study were confirmed to have improved BET surface area and micropore volume through the agar loading, and to exhibit interconnected 3-dimensional network macropore structure leading to the enhancement of total porosity and BET surface area via the foaming process. - Highlights: • Millimeter-sized spherical silica foams (SSFs) are successfully prepared. • SSFs exhibit high BET surface area and ordered hierarchical pore structure. • Agar addition improves BET surface area and micropore volume of SSFs. • Foaming process generates interconnected 3-D network macropore structure of SSFs.« less
Aguirre, Paula; Ojeda, Esther; García, Joan; Barragán, Jesús; Mujeriego, Rafael
2005-01-01
The objective of this article is to evaluate the effect of water depth on organic matter removal efficiency in horizontal subsurface flow constructed wetlands (SSFs). Experiments were carried out in a pilot plant comprising eight parallel SSF of almost equal surface area (54-56 m2 each) and treating urban wastewater. Each SSF differs from the others in the aspect ratio or the size of the granular medium or the water depth. During a period of two years, the shallow SSFs (0.27 m water depth) removed more chemical oxygen demand (COD) (72-81%), biochemical oxygen demand (BOD)5 (72-85%), ammonia (35-56%), and dissolved reactive phosphorus (DRP) (8-23%) than deep SSFs (0.5 m water depth) (59-64% for COD; 51-57% for BOD5; 18-29% for ammonia; and 0-7% for DRP). Experiments carried out during the summer indicated that sulphate reduction accounted for a clearly higher organic matter removal in the deep SSFs than in the shallow ones. Denitrification seemed to be a significant mechanism for organic matter removal to occur in shallow SSFs. The results suggest that the relative contribution of different metabolic pathways varies with depth.
Decompressive craniectomy and hydrocephalus: proposal of a therapeutic flow chart.
Peraio, Simone; Calcagni, Maria Lucia; Mattoli, Maria Vittoria; Marziali, Giammaria; DE Bonis, Pasquale; Pompucci, Angelo; Anile, Carmelo; Mangiola, Annunziato
2017-12-01
Decompressive craniectomy (DC) may be necessary to save the lives of patients suffering from intracranial hypertension. However, this procedure is not complication-free. Its two main complications are hydrocephalus and the sinking skin-flap syndrome (SSFS). The radiological findings and the clinical evaluation may be not enough to decide when and/or how to treat hydrocephalus in a decompressed patient. SSFS and hydrocephalus may be not unrelated. In fact, a patient affected by hydrocephalus, after the ventriculo-peritoneal shunt, can develop SSFS; on the other hand, SSFS per se can cause hydrocephalus. Treating hydrocephalus in decompressed patients can be challenging. Radiological findings and clinical evaluation may not be enough to define the most appropriate therapeutic strategy. Cerebrospinal fluid (CSF) dynamics and metabolic evaluations can represent important diagnostic tools for assessing the need of a CSF shunt in patients with a poor baseline neurologic status. Based on our experience, we propose a flow chart for treating decompressed patients affected by ventriculomegaly.
Basurto, Xavier; Schlüter, Maja
2017-01-01
Small-scale fisheries (SSFs) in developing countries are expected to play a significant role in poverty alleviation and enhancing food security in the decades to come. To realize this expectation, a better understanding of their informal self-governance arrangements is critical for developing policies that can improve fishers’ livelihoods and lead to sustainable ecosystem stewardship. The goal of this paper is to develop a more nuanced understanding of micro-level factors—such as fishers’ characteristics and behavior—to explain observed differences in self-governance arrangements in Northwest Mexico. We focus on two ubiquitous forms of self-governance: hierarchical non-cooperative arrangements between fishers and fishbuyers, such as patron-client relationships (PCs), versus more cooperative arrangements amongst fishers, such as fishing cooperatives (co-ops). We developed an agent-based model of an archetypical SSF that captures key hypotheses from in-depth fieldwork in Northwest Mexico of fishers’ day-to-day fishing and trading. Results from our model indicate that high diversity in fishers’ reliability, and low initial trust between co-op members, makes co-ops’ establishment difficult. PCs cope better with this kind of diversity because, in contrast to co-ops, they have more flexibility in choosing whom to work with. However, once co-ops establish, they cope better with seasonal variability in fish abundance and provide long-term security for the fishers. We argue that existing levels of trust and diversity among fishers matter for different self-governance arrangements to establish and persist, and should therefore be taken into account when developing better, targeted policies for improved SSFs governance. PMID:28406935
Lindkvist, Emilie; Basurto, Xavier; Schlüter, Maja
2017-01-01
Small-scale fisheries (SSFs) in developing countries are expected to play a significant role in poverty alleviation and enhancing food security in the decades to come. To realize this expectation, a better understanding of their informal self-governance arrangements is critical for developing policies that can improve fishers' livelihoods and lead to sustainable ecosystem stewardship. The goal of this paper is to develop a more nuanced understanding of micro-level factors-such as fishers' characteristics and behavior-to explain observed differences in self-governance arrangements in Northwest Mexico. We focus on two ubiquitous forms of self-governance: hierarchical non-cooperative arrangements between fishers and fishbuyers, such as patron-client relationships (PCs), versus more cooperative arrangements amongst fishers, such as fishing cooperatives (co-ops). We developed an agent-based model of an archetypical SSF that captures key hypotheses from in-depth fieldwork in Northwest Mexico of fishers' day-to-day fishing and trading. Results from our model indicate that high diversity in fishers' reliability, and low initial trust between co-op members, makes co-ops' establishment difficult. PCs cope better with this kind of diversity because, in contrast to co-ops, they have more flexibility in choosing whom to work with. However, once co-ops establish, they cope better with seasonal variability in fish abundance and provide long-term security for the fishers. We argue that existing levels of trust and diversity among fishers matter for different self-governance arrangements to establish and persist, and should therefore be taken into account when developing better, targeted policies for improved SSFs governance.
Bioaugmentation Mitigates the Impact of Estrogen on Coliform-Grazing Protozoa in Slow Sand Filters.
Haig, Sarah-Jane; Gauchotte-Lindsay, Caroline; Collins, Gavin; Quince, Christopher
2016-03-15
Exposure to endocrine-disrupting chemicals (EDCs), such as estrogens, is a growing issue for human and animal health as they have been shown to cause reproductive and developmental abnormalities in wildlife and plants and have been linked to male infertility disorders in humans. Intensive farming and weather events, such as storms, flash flooding, and landslides, contribute estrogen to waterways used to supply drinking water. This paper explores the impact of estrogen exposure on the performance of slow sand filters (SSFs) used for water treatment. The feasibility and efficacy of SSF bioaugmentation with estrogen-degrading bacteria was also investigated, to determine whether removal of natural estrogens (estrone, estradiol, and estriol) and overall SSF performance for drinking water treatment could be improved. Strains for SSF augmentation were isolated from full-scale, municipal SSFs so as to optimize survival in the laboratory-scale SSFs used. Concentrations of the natural estrogens, determined by gas chromatography coupled with mass spectrometry (GC-MS), revealed augmented SSFs reduced the overall estrogenic potency of the supplied water by 25% on average and removed significantly more estrone and estradiol than nonaugmented filters. A negative correlation was found between coliform removal and estrogen concentration in nonaugmented filters. This was due to the toxic inhibition of protozoa, indicating that high estrogen concentrations can have functional implications for SSFs (such as impairing coliform removal). Consequently, we suggest that high estrogen concentrations could impact significantly on water quality production and, in particular, on pathogen removal in biological water filters.
Using step and path selection functions for estimating resistance to movement: Pumas as a case study
Katherine A. Zeller; Kevin McGarigal; Samuel A. Cushman; Paul Beier; T. Winston Vickers; Walter M. Boyce
2015-01-01
GPS telemetry collars and their ability to acquire accurate and consistently frequent locations have increased the use of step selection functions (SSFs) and path selection functions (PathSFs) for studying animal movement and estimating resistance. However, previously published SSFs and PathSFs often do not accommodate multiple scales or multiscale modeling....
Haig, Sarah-Jane; Quince, Christopher; Davies, Robert L; Dorea, Caetano C; Collins, Gavin
2014-09-15
Previous laboratory-scale studies to characterise the functional microbial ecology of slow sand filters have suffered from methodological limitations that could compromise their relevance to full-scale systems. Therefore, to ascertain if laboratory-scale slow sand filters (L-SSFs) can replicate the microbial community and water quality production of industrially operated full-scale slow sand filters (I-SSFs), eight cylindrical L-SSFs were constructed and were used to treat water from the same source as the I-SSFs. Half of the L-SSFs sand beds were composed of sterilized sand (sterile) from the industrial filters and the other half with sand taken directly from the same industrial filter (non-sterile). All filters were operated for 10 weeks, with the microbial community and water quality parameters sampled and analysed weekly. To characterize the microbial community phyla-specific qPCR assays and 454 pyrosequencing of the 16S rRNA gene were used in conjunction with an array of statistical techniques. The results demonstrate that it is possible to mimic both the water quality production and the structure of the microbial community of full-scale filters in the laboratory - at all levels of taxonomic classification except OTU - thus allowing comparison of LSSF experiments with full-scale units. Further, it was found that the sand type composing the filter bed (non-sterile or sterile), the water quality produced, the age of the filters and the depth of sand samples were all significant factors in explaining observed differences in the structure of the microbial consortia. This study is the first to the authors' knowledge that demonstrates that scaled-down slow sand filters can accurately reproduce the water quality and microbial consortia of full-scale slow sand filters. Copyright © 2014 Elsevier Ltd. All rights reserved.
Friends with benefits: the evolved psychology of same- and opposite-sex friendship.
Lewis, David M G; Conroy-Beam, Daniel; Al-Shawaf, Laith; Raja, Annia; DeKay, Todd; Buss, David M
2011-12-08
During human evolution, men and women faced distinct adaptive problems, including pregnancy, hunting, childcare, and warfare. Due to these sex-linked adaptive problems, natural selection would have favored psychological mechanisms that oriented men and women toward forming friendships with individuals possessing characteristics valuable for solving these problems. The current study explored sex-differentiated friend preferences and the psychological design features of same- and opposite-sex friendship in two tasks. In Task 1, participants (N = 121) categorized their same-sex friends (SSFs) and opposite-sex friends (OSFs) according to the functions these friends serve in their lives. In Task 2, participants designed their ideal SSFs and OSFs using limited budgets that forced them to make trade-offs between the characteristics they desire in their friends. In Task 1, men, more than women, reported maintaining SSFs for functions related to athleticism and status enhancement and OSFs for mating opportunities. In Task 2, both sexes prioritized agreeableness and dependability in their ideal SSFs, but men prioritized physical attractiveness in their OSFs, whereas women prioritized economic resources and physical prowess. These findings suggest that friend preferences may have evolved to solve ancestrally sex-linked adaptive problems, and that opposite-sex friendship may directly or indirectly serve mating functions.
Liu, Bo-Wen; Hu, Ming-Lie; Fang, Xiao-Hui; Li, Yan-Feng; Chai, Lu; Wang, Ching-Yue; Tong, Weijun; Luo, Jie; Voronin, Aleksandr A; Zheltikov, Aleksei M
2008-09-15
Fiber dispersion and nonlinearity management strategy based on a modification of a photonic-crystal fiber (PCF) core with an air hole is shown to facilitate optimization of PCF components for a stable soliton frequency shift and subpetahertz sideband generation through four-wave mixing. Spectral recoil of an optical soliton by a red-shifted dispersive wave, generated through a soliton instability induced by high-order fiber dispersion, is shown to stabilize the soliton self-frequency shift in a highly nonlinear PCF with an air-hole-modified core relative to pump power variations. A fiber with a 2.3-microm-diameter core modified with a 0.9-microm-diameter air hole is used to demonstrate a robust soliton self-frequency shift of unamplified 50-fs Ti: sapphire laser pulses to a central wavelength of about 960 nm, which remains insensitive to variations in the pump pulse energy within the range from 60 to at least 100 pJ. In this regime of frequency shifting, intense high- and low-frequency branches of dispersive wave radiation are simultaneously observed in the spectrum of PCF output. An air-hole-modified-core PCF with appropriate dispersion and nonlinearity parameters is shown to provide efficient four-wave mixing, giving rise to Stokes and anti-Stokes sidebands whose frequency shift relative to the pump wavelength falls within the subpetahertz range, thus offering an attractive source for nonlinear Raman microspectroscopy.
Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.
1992-01-01
In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.
Guan, Liu; Zhao, Jiahao; Yu, Shijie; Li, Peng; You, Zheng
2010-01-01
Micro-cantilever sensors for mass detection using resonance frequency have attracted considerable attention over the last decade in the field of gas sensing. For such a sensing system, an oscillator circuit loop is conventionally used to actuate the micro-cantilever, and trace the frequency shifts. In this paper, gas experiments are introduced to investigate the mechanical resonance frequency shifts of the micro-cantilever within the circuit loop(mechanical resonance frequency, MRF) and resonating frequency shifts of the electric signal in the oscillator circuit (system working frequency, SWF). A silicon beam with a piezoelectric zinc oxide layer is employed in the experiment, and a Self-Actuating-Detecting (SAD) circuit loop is built to drive the micro-cantilever and to follow the frequency shifts. The differences between the two resonating frequencies and their shifts are discussed and analyzed, and a coefficient α related to the two frequency shifts is confirmed. PMID:22163588
Improved Intrapulse Raman Scattering Control via Asymmetric Airy Pulses
NASA Astrophysics Data System (ADS)
Hu, Yi; Tehranchi, Amirhossein; Wabnitz, Stefan; Kashyap, Raman; Chen, Zhigang; Morandotti, Roberto
2015-02-01
We experimentally demonstrate the possibility of tuning the frequency of a laser pulse via the use of an Airy pulse-seeded soliton self-frequency shift. The intrinsically asymmetric nature of Airy pulses, typically featured by either leading or trailing oscillatory tails (relatively to the main lobe), is revealed through the nonlinear generation of both a primary and a secondary Raman soliton self-frequency shift, a phenomenon which is driven by the soliton fission processes. The resulting frequency shift can be carefully controlled by using time-reversed Airy pulses or, alternatively, by applying an offset to the cubic phase modulation used to generate the pulses. When compared with the use of conventional chirped Gaussian pulses, our technique brings about unique advantages in terms of both efficient frequency tuning and feasibility, along with the generation and control of multicolor Raman solitons with enhanced tunability. Our theoretical analysis agrees well with our experimental observations.
Chen, Lin-Yuan; Tang, Ping-Han; Wu, Ten-Ming
2016-07-14
In terms of the local bond-orientational order (LBOO) parameters, a cluster approach to analyze local structures of simple liquids was developed. In this approach, a cluster is defined as a combination of neighboring seeds having at least nb local-orientational bonds and their nearest neighbors, and a cluster ensemble is a collection of clusters with a specified nb and number of seeds ns. This cluster analysis was applied to investigate the microscopic structures of liquid Ga at ambient pressure (AP). The liquid structures studied were generated through ab initio molecular dynamics simulations. By scrutinizing the static structure factors (SSFs) of cluster ensembles with different combinations of nb and ns, we found that liquid Ga at AP contained two types of cluster structures, one characterized by sixfold orientational symmetry and the other showing fourfold orientational symmetry. The SSFs of cluster structures with sixfold orientational symmetry were akin to the SSF of a hard-sphere fluid. On the contrary, the SSFs of cluster structures showing fourfold orientational symmetry behaved similarly as the anomalous SSF of liquid Ga at AP, which is well known for exhibiting a high-q shoulder. The local structures of a highly LBOO cluster whose SSF displayed a high-q shoulder were found to be more similar to the structure of β-Ga than those of other solid phases of Ga. More generally, the cluster structures showing fourfold orientational symmetry have an inclination to resemble more to β-Ga.
Examining speed versus selection in connectivity models using elk migration as an example
Brennan, Angela; Hanks, Ephraim M.; Merkle, Jerod A.; Cole, Eric K.; Dewey, Sarah R.; Courtemanch, Alyson B.; Cross, Paul C.
2018-01-01
ContextLandscape resistance is vital to connectivity modeling and frequently derived from resource selection functions (RSFs). RSFs estimate relative probability of use and tend to focus on understanding habitat preferences during slow, routine animal movements (e.g., foraging). Dispersal and migration, however, can produce rarer, faster movements, in which case models of movement speed rather than resource selection may be more realistic for identifying habitats that facilitate connectivity.ObjectiveTo compare two connectivity modeling approaches applied to resistance estimated from models of movement rate and resource selection.MethodsUsing movement data from migrating elk, we evaluated continuous time Markov chain (CTMC) and movement-based RSF models (i.e., step selection functions [SSFs]). We applied circuit theory and shortest random path (SRP) algorithms to CTMC, SSF and null (i.e., flat) resistance surfaces to predict corridors between elk seasonal ranges. We evaluated prediction accuracy by comparing model predictions to empirical elk movements.ResultsAll connectivity models predicted elk movements well, but models applied to CTMC resistance were more accurate than models applied to SSF and null resistance. Circuit theory models were more accurate on average than SRP models.ConclusionsCTMC can be more realistic than SSFs for estimating resistance for fast movements, though SSFs may demonstrate some predictive ability when animals also move slowly through corridors (e.g., stopover use during migration). High null model accuracy suggests seasonal range data may also be critical for predicting direct migration routes. For animals that migrate or disperse across large landscapes, we recommend incorporating CTMC into the connectivity modeling toolkit.
Examining speed versus selection in connectivity models using elk migration as an example
Brennan, Angela; Hanks, EM; Merkle, JA; Cole, EK; Dewey, SR; Courtemanch, AB; Cross, Paul C.
2018-01-01
Context: Landscape resistance is vital to connectivity modeling and frequently derived from resource selection functions (RSFs). RSFs estimate relative probability of use and tend to focus on understanding habitat preferences during slow, routine animal movements (e.g., foraging). Dispersal and migration, however, can produce rarer, faster movements, in which case models of movement speed rather than resource selection may be more realistic for identifying habitats that facilitate connectivity. Objective: To compare two connectivity modeling approaches applied to resistance estimated from models of movement rate and resource selection. Methods: Using movement data from migrating elk, we evaluated continuous time Markov chain (CTMC) and movement-based RSF models (i.e., step selection functions [SSFs]). We applied circuit theory and shortest random path (SRP) algorithms to CTMC, SSF and null (i.e., flat) resistance surfaces to predict corridors between elk seasonal ranges. We evaluated prediction accuracy by comparing model predictions to empirical elk movements. Results: All models predicted elk movements well, but models applied to CTMC resistance were more accurate than models applied to SSF and null resistance. Circuit theory models were more accurate on average than SRP algorithms. Conclusions: CTMC can be more realistic than SSFs for estimating resistance for fast movements, though SSFs may demonstrate some predictive ability when animals also move slowly through corridors (e.g., stopover use during migration). High null model accuracy suggests seasonal range data may also be critical for predicting direct migration routes. For animals that migrate or disperse across large landscapes, we recommend incorporating CTMC into the connectivity modeling toolkit.
Merkle, Jerod A.; Cross, Paul C.; Scurlock, Brandon M.; Cole, Eric K.; Courtemanch, Alyson B.; Dewey, Sarah R.; Kauffman, Matthew J.
2018-01-01
Disease models typically focus on temporal dynamics of infection, while often neglecting environmental processes that determine host movement. In many systems, however, temporal disease dynamics may be slow compared to the scale at which environmental conditions alter host space-use and accelerate disease transmission.Using a mechanistic movement modelling approach, we made space-use predictions of a mobile host (elk [Cervus Canadensis] carrying the bacterial disease brucellosis) under environmental conditions that change daily and annually (e.g., plant phenology, snow depth), and we used these predictions to infer how spring phenology influences the risk of brucellosis transmission from elk (through aborted foetuses) to livestock in the Greater Yellowstone Ecosystem.Using data from 288 female elk monitored with GPS collars, we fit step selection functions (SSFs) during the spring abortion season and then implemented a master equation approach to translate SSFs into predictions of daily elk distribution for five plausible winter weather scenarios (from a heavy snow, to an extreme winter drought year). We predicted abortion events by combining elk distributions with empirical estimates of daily abortion rates, spatially varying elk seroprevelance and elk population counts.Our results reveal strong spatial variation in disease transmission risk at daily and annual scales that is strongly governed by variation in host movement in response to spring phenology. For example, in comparison with an average snow year, years with early snowmelt are predicted to have 64% of the abortions occurring on feedgrounds shift to occurring on mainly public lands, and to a lesser extent on private lands.Synthesis and applications. Linking mechanistic models of host movement with disease dynamics leads to a novel bridge between movement and disease ecology. Our analysis framework offers new avenues for predicting disease spread, while providing managers tools to proactively mitigate risks posed by mobile disease hosts. More broadly, we demonstrate how mechanistic movement models can provide predictions of ecological conditions that are consistent with climate change but may be more extreme than has been observed historically.
Stenehjem, Jo S; Friesen, Melissa C; Eggen, Tone; Kjærheim, Kristina; Bråtveit, Magne; Grimsrud, Tom K
2016-01-01
The objective of this study was to examine self-reported frequency of occupational exposure reported by 28,000 Norwegian offshore oil workers in a 1998 survey. Predictors of self-reported exposure frequency were identified to aid future refinements of an expert-based job-exposure-time matrix (JEM). We focus here on reported frequencies for skin contact with oil and diesel, exposure to oil vapor from shaker, to exhaust fumes, vapor from mixing chemicals used for drilling, natural gas, chemicals used for water injection and processing, and to solvent vapor. Exposure frequency was reported by participants as the exposed proportion of the work shift, defined by six categories, in their current or last position offshore (between 1965 and 1999). Binary Poisson regression models with robust variance were used to examine the probabilities of reporting frequent exposure (≥¼ vs. <¼ of work shift) according to main activity, time period, supervisory position, type of company, type of installation, work schedule, and education. Holding a non-supervisory position, working shifts, being employed in the early period of the offshore industry, and having only compulsory education increased the probability of reporting frequent exposure. The identified predictors and group-level patterns may aid future refinement of the JEM previously developed for the present cohort. PMID:25671393
Stenehjem, Jo S; Friesen, Melissa C; Eggen, Tone; Kjærheim, Kristina; Bråtveit, Magne; Grimsrud, Tom K
2015-01-01
The objective of this study was to examine self-reported frequency of occupational exposure reported by 28,000 Norwegian offshore oil workers in a 1998 survey. Predictors of self-reported exposure frequency were identified to aid future refinements of an expert-based job-exposure-time matrix (JEM). We focus here on reported frequencies for skin contact with oil and diesel; exposure to oil vapor from shaker, to exhaust fumes, vapor from mixing chemicals used for drilling, natural gas, chemicals used for water injection and processing, and to solvent vapor. Exposure frequency was reported by participants as the exposed proportion of the work shift, defined by six categories, in their current or last position offshore (between 1965 and 1999). Binary Poisson regression models with robust variance were used to examine the probabilities of reporting frequent exposure (≥¼ vs. <¼ of work shift) according to main activity, time period, supervisory position, type of company, type of installation, work schedule, and education. Holding a non-supervisory position, working shifts, being employed in the early period of the offshore industry, and having only compulsory education increased the probability of reporting frequent exposure. The identified predictors and group-level patterns may aid future refinement of the JEM previously developed for the present cohort.
Coupling of conservative and dissipative forces in frequency-modulation atomic force microscopy
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2006-11-01
Frequency modulation atomic force microscopy (FM-AFM) utilizes the principle of self-excitation to ensure the cantilever probe vibrates at its resonant frequency, regardless of the tip-sample interaction. Practically, this is achieved by fixing the phase difference between tip deflection and driving force at precisely 90° . This, in turn, decouples the frequency shift and excitation amplitude signals, enabling quantitative interpretation in terms of conservative and dissipative tip-sample interaction forces. In this article, we theoretically investigate the effect of phase detuning in the self-excitation mechanism on the coupling between conservative and dissipative forces in FM-AFM. We find that this coupling depends only on the relative difference in the drive and resonant frequencies far from the surface, and is thus very weakly dependent on the actual phase error particularly for high quality factors. This establishes that FM-AFM is highly robust with respect to phase detuning, and enables quantitative interpretation of the measured frequency shift and excitation amplitude, even while operating away from the resonant frequency with the use of appropriate replacements in the existing formalism. We also examine the calibration of phase shifts in FM-AFM measurements and demonstrate that the commonly used approach of minimizing the excitation amplitude can lead to significant phase detuning, particularly in liquid environments.
Koptev, M Yu; Anashkina, E A; Andrianov, A V; Dorofeev, V V; Kosolapov, A F; Muravyev, S V; Kim, A V
2015-09-01
A turnkey fiber laser source generating high-quality pulses with a spectral sech shape and Fourier transform-limited duration of order 100 fs widely tunable in the 1.6-2.65 μm range is presented. It is based on Raman soliton self-frequency shifting in the suspended-core microstructured TeO2-WO3-La2O3 glass fiber pumped by a hybrid Er/Tm fiber system. Detailed experimental and theoretical studies, which are in a very good agreement, of nonlinear pulse dynamics in the tellurite fiber with carefully measured and calculated parameters are reported. A quantitatively verified numerical model is used to show Raman soliton shift in the range well beyond 3 μm for increased pump energy.
Far-infrared self-broadening in methylcyanide - Absorber-perturber resonance
NASA Technical Reports Server (NTRS)
Buffa, G.; Tarrini, O.; De Natale, P.; Inguscio, M.; Pavone, F. S.; Prevedelli, M.; Evenson, K. M.; Zink, L. R.; Schwaab, G. W.
1992-01-01
Using tunable far-infrared spectrometers with high-frequency stability and accuracy, the self-pressure broadening and shift of CH3CN are measured. Evidence of absorber-perturber resonance effects on the collisional line shape are obtained. This tests the theoretical model and its possible improvements and also allows predictions of broadening and shift for a large class of molecules. Moreover, the resonance effect produces a theoretical temperature dependence of self-broadening that is different from what is commonly assumed.
A self-reference PRF-shift MR thermometry method utilizing the phase gradient
NASA Astrophysics Data System (ADS)
Langley, Jason; Potter, William; Phipps, Corey; Huang, Feng; Zhao, Qun
2011-12-01
In magnetic resonance (MR) imaging, the most widely used and accurate method for measuring temperature is based on the shift in proton resonance frequency (PRF). However, inter-scan motion and bulk magnetic field shifts can lead to inaccurate temperature measurements in the PRF-shift MR thermometry method. The self-reference PRF-shift MR thermometry method was introduced to overcome such problems by deriving a reference image from the heated or treated image, and approximates the reference phase map with low-order polynomial functions. In this note, a new approach is presented to calculate the baseline phase map in self-reference PRF-shift MR thermometry. The proposed method utilizes the phase gradient to remove the phase unwrapping step inherent to other self-reference PRF-shift MR thermometry methods. The performance of the proposed method was evaluated using numerical simulations with temperature distributions following a two-dimensional Gaussian function as well as phantom and in vivo experimental data sets. The results from both the numerical simulations and experimental data show that the proposed method is a promising technique for measuring temperature.
Low-frequency, self-sustained oscillations in inductively coupled plasmas used for optical pumping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coffer, J.; Encalada, N.; Huang, M.
We have investigated very low frequency, on the order of one hertz, self-pulsing in alkali-metal inductively-coupled plasmas (i.e., rf-discharge lamps). This self-pulsing has the potential to significantly vary signal-to-noise ratios and (via the ac-Stark shift) resonant frequencies in optically pumped atomic clocks and magnetometers (e.g., the atomic clocks now flying on GPS and Galileo global navigation system satellites). The phenomenon arises from a nonlinear interaction between the atomic physics of radiation trapping and the plasma's electrical nature. To explain the effect, we have developed an evaporation/condensation theory (EC theory) of the self-pulsing phenomenon.
Vibration and noise characteristics of an elevated box girder paved with different track structures
NASA Astrophysics Data System (ADS)
Li, Xiaozhen; Liang, Lin; Wang, Dangxiong
2018-07-01
The vibration and noise of elevated concrete box girders (ECBGs) are now among the most concerned issues in the field of urban rail transit (URT) systems. The track structure, belonging to critical load-transfer components, directly affects the characteristics of loading transmission into bridge, as well as the noise radiation from such system, which further determines the reduction of vibration and noise in ECBGs significantly. In order to investigate the influence of different track structures on the vibration and structure-borne noise of ECBGs, a frequency-domain theoretical model of vehicle-track coupled system, taking into account the effect of multiple wheels, is firstly established in the present work. The analysis of track structures focuses on embedded sleepers, trapezoidal sleepers, and steel-spring floating slabs (SSFS). Next, a vibration and noise field test was performed, with regard to a 30 m simple supported ECBG (with the embedded-sleeper track structure) of an URT system. Based on the tested results, two numerical models, involving a finite element model for the vibration analysis, as well as a statistical energy analysis (SEA) model for the prediction of the noise radiation, are established and validated. The results of the numerical simulations and the field tests are well matched, which offers opportunities to predict the vibration and structure-borne noise of ECBGs by the proposed modelling methodology. From the comparison between the different types of track structures, the spatial distribution and reduction effect of vibration and noise are lastly studied. The force applied on ECBG is substantially determined by both the wheel-rail force (external factor) and the transmission rate of track structure (internal factor). The SSFS track is the most effective for vibration and noise reduction of ECBGs, followed in descending order by the trapezoidal-sleeper and embedded-sleeper tracks. The above result provides a theoretical basis for the vibration and noise reduction design of urban rail transit systems.
Estimation of Occupational Test Norms from Job Analysis Data.
ERIC Educational Resources Information Center
Mecham, Robert C.
Occupational norms exist for some tests, and differences in the distributions of test scores by occupation are evident. Sampling error (SE), situationally specific factors (SSFs), and differences in job content (DIJCs) were explored as possible reasons for the observed differences. SE was explored by analyzing 742 validity studies performed by the…
Self-energy behavior away from the Fermi surface in doped Mott insulators.
Merino, J; Gunnarsson, O; Kotliar, G
2016-02-03
We analyze self-energies of electrons away from the Fermi surface in doped Mott insulators using the dynamical cluster approximation to the Hubbard model. For large onsite repulsion, U, and hole doping, the magnitude of the self-energy for imaginary frequencies at the top of the band ([Formula: see text]) is enhanced with respect to the self-energy magnitude at the bottom of the band ([Formula: see text]). The self-energy behavior at these two [Formula: see text]-points is switched for electron doping. Although the hybridization is much larger for (0, 0) than for [Formula: see text], we demonstrate that this is not the origin of this difference. Isolated clusters under a downward shift of the chemical potential, [Formula: see text], at half-filling reproduce the overall self-energy behavior at (0, 0) and [Formula: see text] found in low hole doped embedded clusters. This happens although there is no change in the electronic structure of the isolated clusters. Our analysis shows that a downward shift of the chemical potential which weakly hole dopes the Mott insulator can lead to a large enhancement of the [Formula: see text] self-energy for imaginary frequencies which is not associated with electronic correlation effects, even in embedded clusters. Interpretations of the strength of electronic correlations based on self-energies for imaginary frequencies are, in general, misleading for states away from the Fermi surface.
Probe-controlled soliton frequency shift in the regime of optical event horizon.
Gu, Jie; Guo, Hairun; Wang, Shaofei; Zeng, Xianglong
2015-08-24
In optical analogy of the event horizon, temporal pulse collision and mutual interactions are mainly between an intense solitary wave (soliton) and a dispersive probe wave. In such a regime, here we numerically investigate the probe-controlled soliton frequency shift as well as the soliton self-compression. In particular, in the dispersion landscape with multiple zero dispersion wavelengths, bi-directional soliton spectral tunneling effects is possible. Moreover, we propose a mid-infrared soliton self-compression to the generation of few-cycle ultrashort pulses, in a bulk of quadratic nonlinear crystals in contrast to optical fibers or cubic nonlinear media, which could contribute to the community with a simple and flexible method to experimental implementations.
Duffing revisited: phase-shift control and internal resonance in self-sustained oscillators
NASA Astrophysics Data System (ADS)
Arroyo, Sebastián I.; Zanette, Damián H.
2016-01-01
We address two aspects of the dynamics of the forced Duffing oscillator which are relevant to the technology of micromechanical devices and, at the same time, have intrinsic significance to the field of nonlinear oscillating systems. First, we study the stability of periodic motion when the phase shift between the external force and the oscillation is controlled - contrary to the standard case, where the control parameter is the frequency of the force. Phase-shift control is the operational configuration under which self-sustained oscillators - and, in particular, micromechanical oscillators - provide a frequency reference useful for time keeping. We show that, contrary to the standard forced Duffing oscillator, under phase-shift control oscillations are stable over the whole resonance curve, and provide analytical approximate expressions for the time dependence of the oscillation amplitude and frequency during transients. Second, we analyze a model for the internal resonance between the main Duffing oscillation mode and a higher-harmonic mode of a vibrating solid bar clamped at its two ends. We focus on the stabilization of the oscillation frequency when the resonance takes place, and present preliminary experimental results that illustrate the phenomenon. This synchronization process has been proposed to counteract the undesirable frequency-amplitude interdependence in nonlinear time-keeping micromechanical devices. Supplementary material in the form of one pdf file and one gif file available from the Journal web page at http://dx.doi.org/10.1140/epjb/e2015-60517-3
NASA Astrophysics Data System (ADS)
Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.
2017-11-01
This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.
Chen, Vivien W.; Ruiz, Bernardo A.; Hsieh, Mei-Chin; Wu, Xiao-Cheng; Ries, Lynn; Lewis, Denise R.
2014-01-01
Introduction The American Joint Committee on Cancer (AJCC) 7th edition introduced major changes in the staging of lung cancer, including Tumor (T), Node (N), Metastasis (M) (TNM) system and new stage/prognostic site-specific factors (SSFs), collected under the Collaborative Stage Version 2 (CSv2) Data Collection System. The intent was to improve the stage precision which could guide treatment options and ultimately lead to better survival. This report examines stage trends, the change in stage distributions from the AJCC 6th to the 7th edition, and findings of the prognostic SSFs for 2010 lung cancer cases. Methods Data were from the November 2012 submission of 18 Surveillance, Epidemiology, and End Results (SEER) Program population-based registries. A total of 344 797 cases of lung cancer, diagnosed in 2004–2010, were analyzed. Results The percentages of small tumors and early stage lung cancer cases increased from 2004 to 2010. The AJCC 7th edition, implemented for 2010 diagnosis year, subclassified tumor size and reclassified multiple tumor nodules, pleural effusions, and involvement of tumors in the contralateral lung, resulting in a slight decrease in stage IB and stage IIIB and a small increase in stage IIA and stage IV. Overall about 80% of cases remained the same stage group in AJCC 6th and 7th editions. About 21% of lung cancer patients had separate tumor nodules in the ipsilateral (same) lung, and 23% of the surgically resected patients had visceral pleural invasion, both adverse prognostic factors. Conclusion It is feasible for high quality population-based registries such as the SEER Program to collect more refined staging and prognostic SSFs that allows better categorization of lung cancer patients with different clinical outcomes and to assess their survival. PMID:25412390
Night-shift work and breast cancer risk in a cohort of Chinese women.
Pronk, Anjoeka; Ji, Bu-Tian; Shu, Xiao-Ou; Xue, Shouzheng; Yang, Gong; Li, Hong-Lan; Rothman, Nathaniel; Gao, Yu-Tang; Zheng, Wei; Chow, Wong-Ho
2010-05-01
Shift work involving disruption of circadian rhythms has been classified as a probable cause of human cancer by the International Agency for Research on Cancer, based on limited epidemiologic evidence and abundant experimental evidence. The authors investigated this association in a population-based prospective cohort study of Chinese women. At baseline (1996-2000), information on lifetime occupational history was obtained from 73,049 women. Lifetime night-shift exposure indices were created using a job exposure matrix. During 2002-2004, self-reported data on frequency and duration of night-shift work were collected. Hazard ratios and 95% confidence intervals, adjusted for major breast cancer risk factors, were calculated. During follow-up through 2007, 717 incident cases of breast cancer were diagnosed. Breast cancer risk was not associated with ever working the night shift on the basis of the job exposure matrix (adjusted hazard ratio = 1.0, 95% confidence interval: 0.9, 1.2) or self-reported history of night-shift work (adjusted hazard ratio = 0.9, 95% confidence interval: 0.7, 1.1). Risk was also not associated with frequency, duration, or cumulative amount of night-shift work. There were no indications of effect modification. The lack of an association between night-shift work and breast cancer adds to the inconsistent epidemiologic evidence. It may be premature to consider shift work a cause of cancer.
Peregrine rogue waves induced by the interaction between a continuous wave and a soliton.
Yang, Guangye; Li, Lu; Jia, Suotang
2012-04-01
Based on the soliton solution on a continuous wave background for an integrable Hirota equation, the reduction mechanism and the characteristics of the Peregrine rogue wave in the propagation of femtosecond pulses of optical fiber are discussed. The results show that there exist two processes of the formation of the Peregrine rogue wave: one is the localized process of the continuous wave background, and the other is the reduction process of the periodization of the bright soliton. The characteristics of the Peregrine rogue wave are exhibited by strong temporal and spatial localization. Also, various initial excitations of the Peregrine rogue wave are performed and the results show that the Peregrine rogue wave can be excited by a small localized (single peak) perturbation pulse of the continuous wave background, even for the nonintegrable case. The numerical simulations show that the Peregrine rogue wave is unstable. Finally, through a realistic example, the influence of the self-frequency shift to the dynamics of the Peregrine rogue wave is discussed. The results show that in the absence of the self-frequency shift, the Peregrine rogue wave can split into several subpulses; however, when the self-frequency shift is considered, the Peregrine rogue wave no longer splits and exhibits mainly a peak changing and an increasing evolution property of the field amplitude.
Two MODIS Aerosol Products Over Ocean on the Terra and Aqua CERES SSF Datasets
NASA Technical Reports Server (NTRS)
Ignatov, Alexander; Minnis, Patrick; Loeb, Norman; Wielicki, Bruce; Miller, Walter; Sun-Mack, Sunny; Tanre, Didier; Remer, Lorraine; Laszlo, Istvan; Geier, Erika
2004-01-01
Over ocean, two aerosol products are reported on the Terra and Aqua CERES SSFs. Both are derived from MODIS, but using different sampling and aerosol algorithms. This study briefly summarizes these products, and compares using 2 weeks of global Terra data from 15-21 December 2000, and 1-7 June 2001.
Isoyama, Soichiro; Barack, Leor; Dolan, Sam R; Le Tiec, Alexandre; Nakano, Hiroyuki; Shah, Abhay G; Tanaka, Takahiro; Warburton, Niels
2014-10-17
For a self-gravitating particle of mass μ in orbit around a Kerr black hole of mass M ≫ μ, we compute the O(μ/M) shift in the frequency of the innermost stable circular equatorial orbit due to the conservative piece of the gravitational self-force acting on the particle. Our treatment is based on a Hamiltonian formulation of the dynamics in terms of geodesic motion in a certain locally defined effective smooth spacetime. We recover the same result using the so-called first law of binary black-hole mechanics. We give numerical results for the innermost stable circular equatorial orbit frequency shift as a function of the black hole's spin amplitude, and compare with predictions based on the post-Newtonian approximation and the effective one-body model. Our results provide an accurate strong-field benchmark for spin effects in the general-relativistic two-body problem.
Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts
Griffith, Jacob; Cluff, Kim; Eckerman, Brandon; Aldrich, Jessica; Becker, Ryan; Moore-Jansen, Peer; Patterson, Jeremy
2018-01-01
Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure. PMID:29596338
Cascaded c-cut Nd:YVO4 self-Raman laser operation with a single 259 cm-1 shift
NASA Astrophysics Data System (ADS)
Guo, Junhong; Zhu, Haiyong; Duan, Yanmin; Xu, Changwen; Ruan, Xiukai; Cui, Guihua; Yan, Lifen
2017-03-01
A cascaded c-cut Nd:YVO4 crystal self-Raman operation was demonstrated with a Raman shift of 259 cm-1. The Stokes oscillation with a primary Raman shift of 890 cm-1 was suppressed and a cascaded self-Raman with a single Raman shift of 259 cm-1 was realized based on suitable coating design. At an incident pump power of 13.3 W, the second Stokes at 1129 nm was obtained as the main output laser and the output power was about 0.81 W. As the incident pump power increased, dual Stokes at 1129 and 1163 nm were obtained. A maximum output power of up to 1.0 W with a conversion efficiency of 6.7% was achieved at an incident pump power of 14.9 W and a pulse repetition frequency of 15 kHz.
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Ren, A.; Zhang, Y. S.
1991-01-01
In the study of the propagation of high power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. In the very high power region, one has to prevent the cutoff reflection caused by the excessive ionization in the background air. A frequency auto-conversion process which can lead to reflectionless propagation of powerful EM pulses in self-generated plasmas is studied. The theory shows that under the proper conditions the carrier frequency, omega, of the pulse will indeed shift upward with the growth of plasma frequency, omega(sub pe). Thus, the plasma during breakdown will always remain transparent to the pulse (i.e., omega greater than omega(sub pe)). A chamber experiment to demonstrate the frequency auto-conversion during the pulse propagation through the self-generated plasma is then conducted in a chamber. The detected frequency shift is compared with the theoretical result calculated y using the measured electron density distribution along the propagation path of the pulse. Good agreement between the theory and the experiment results is obtained.
NASA Astrophysics Data System (ADS)
Rozanov, N. N.; Kiselev, Al. S.; Kiselev, An. S.
2008-08-01
Self-reflection of pulses of intense laser radiation from an inhomogeneity induced by them in a medium with fast optical nonlinearity is analyzed. The reflected radiation is characterized by a considerable Doppler shift and by a signal magnitude that is sufficient for experimental detection.
Self-Mixing Thin-Slice Solid-State Laser Metrology
Otsuka, Kenju
2011-01-01
This paper reviews the dynamic effect of thin-slice solid-state lasers subjected to frequency-shifted optical feedback, which led to the discovery of the self-mixing modulation effect, and its applications to quantum-noise-limited versatile laser metrology systems with extreme optical sensitivity. PMID:22319406
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Zhang, Y. S.; Ren, A.
1990-01-01
A chamber experiment is conducted to study the propagation of a high-power microwave pulse. The results show that the pulse is experiencing frequency up-shift while ionizing the background air if the initial carrier frequency of the pulse is higher than the electron plasma frequency at the incident boundary. Such a frequency autoconversion process may lead to reflectionless propagation of a high-power microwave pulse through the atmosphere.
NASA Astrophysics Data System (ADS)
di Franco, Antonio; Thiriet, Pierre; di Carlo, Giuseppe; Dimitriadis, Charalampos; Francour, Patrice; Gutiérrez, Nicolas L.; Jeudy de Grissac, Alain; Koutsoubas, Drosos; Milazzo, Marco; Otero, María Del Mar; Piante, Catherine; Plass-Johnson, Jeremiah; Sainz-Trapaga, Susana; Santarossa, Luca; Tudela, Sergi; Guidetti, Paolo
2016-12-01
Marine protected areas (MPAs) have largely proven to be effective tools for conserving marine ecosystem, while socio-economic benefits generated by MPAs to fisheries are still under debate. Many MPAs embed a no-take zone, aiming to preserve natural populations and ecosystems, within a buffer zone where potentially sustainable activities are allowed. Small-scale fisheries (SSF) within buffer zones can be highly beneficial by promoting local socio-economies. However, guidelines to successfully manage SSFs within MPAs, ensuring both conservation and fisheries goals, and reaching a win-win scenario, are largely unavailable. From the peer-reviewed literature, grey-literature and interviews, we assembled a unique database of ecological, social and economic attributes of SSF in 25 Mediterranean MPAs. Using random forest with Boruta algorithm we identified a set of attributes determining successful SSFs management within MPAs. We show that fish stocks are healthier, fishermen incomes are higher and the social acceptance of management practices is fostered if five attributes are present (i.e. high MPA enforcement, presence of a management plan, fishermen engagement in MPA management, fishermen representative in the MPA board, and promotion of sustainable fishing). These findings are pivotal to Mediterranean coastal communities so they can achieve conservation goals while allowing for profitable exploitation of fisheries resources.
Di Franco, Antonio; Thiriet, Pierre; Di Carlo, Giuseppe; Dimitriadis, Charalampos; Francour, Patrice; Gutiérrez, Nicolas L; Jeudy de Grissac, Alain; Koutsoubas, Drosos; Milazzo, Marco; Otero, María Del Mar; Piante, Catherine; Plass-Johnson, Jeremiah; Sainz-Trapaga, Susana; Santarossa, Luca; Tudela, Sergi; Guidetti, Paolo
2016-12-01
Marine protected areas (MPAs) have largely proven to be effective tools for conserving marine ecosystem, while socio-economic benefits generated by MPAs to fisheries are still under debate. Many MPAs embed a no-take zone, aiming to preserve natural populations and ecosystems, within a buffer zone where potentially sustainable activities are allowed. Small-scale fisheries (SSF) within buffer zones can be highly beneficial by promoting local socio-economies. However, guidelines to successfully manage SSFs within MPAs, ensuring both conservation and fisheries goals, and reaching a win-win scenario, are largely unavailable. From the peer-reviewed literature, grey-literature and interviews, we assembled a unique database of ecological, social and economic attributes of SSF in 25 Mediterranean MPAs. Using random forest with Boruta algorithm we identified a set of attributes determining successful SSFs management within MPAs. We show that fish stocks are healthier, fishermen incomes are higher and the social acceptance of management practices is fostered if five attributes are present (i.e. high MPA enforcement, presence of a management plan, fishermen engagement in MPA management, fishermen representative in the MPA board, and promotion of sustainable fishing). These findings are pivotal to Mediterranean coastal communities so they can achieve conservation goals while allowing for profitable exploitation of fisheries resources.
Methods and apparatus for broadband frequency comb stabilization
Cox, Jonathan A; Kaertner, Franz X
2015-03-17
Feedback loops can be used to shift and stabilize the carrier-envelope phase of a frequency comb from a mode-locked fibers laser or other optical source. Compared to other frequency shifting and stabilization techniques, feedback-based techniques provide a wideband closed-loop servo bandwidth without optical filtering, beam pointing errors, or group velocity dispersion. It also enables phase locking to a stable reference, such as a Ti:Sapphire laser, continuous-wave microwave or optical source, or self-referencing interferometer, e.g., to within 200 mrad rms from DC to 5 MHz. In addition, stabilized frequency combs can be coherently combined with other stable signals, including other stabilized frequency combs, to synthesize optical pulse trains with pulse durations of as little as a single optical cycle. Such a coherent combination can be achieved via orthogonal control, using balanced optical cross-correlation for timing stabilization and balanced homodyne detection for phase stabilization.
NASA Astrophysics Data System (ADS)
Kornprobst, Jonas; Mittermaier, Thomas J.; Eibert, Thomas F.
2017-09-01
A new receiving scheme for self-mixing receivers is presented that overcomes the disadvantages of the self-heterodyne concept. Generally speaking, the self-mixing receiver offers immunity to phase noise and frequency offsets, especially at very high frequencies, since it does not require radio frequency local oscillators. Our proposed technique eliminates the drawbacks of the self-heterodyne transmission scheme, which are the poor power efficiency and the strong dependence on the continously transmitted carrier. A nonlinear system of equations is constructed that describes a phase retrieval problem for the reconstruction of the original transmit signal before self-mixing. Two different solution strategies, with restrictions in time and frequency domain, are presented. As a consequence, the self-mixing equation system is shown to be solvable with some a-priori information about the transmit signal. With this novel approach, the transmitted information is distributed over the full available bandwidth, and there is no special dependence on a certain subcarrier for the down-conversion. The general performance, regarding bit error ratio over signal to noise ratio, is improved by at least 2 dB as compared to the self-heterodyne transmission scheme. In the case of frequency selective channels, e.g. multi-path propagation, this improvement is shown to be much larger, because the presented approach is able to reconstruct the received subcarriers without the necessity of receiving all subcarriers.
Ingre, Michael; Åkerstedt, Torbjörn; Ekstedt, Mirjam; Kecklund, Göran
2012-07-01
The main objective of the present study was to investigate relative personal fit as the association between rated needs and preferences for work hours, on the one hand, and actual work hours, on the other hand, in three groups (hospital, call-center, and police) working with periodic self-rostering. We also examined the association between personal fit and satisfaction with the work schedule and preference for a fixed and regular shift schedule, respectively. We collected questionnaire data and objective work hour data over 6-12 months from the computerized self-rostering system. The response rate of the questionnaire was 69% at the hospital and call-center and 98% among the police. In total, 29 433 shifts for 285 shift workers were included in the study. Data was analyzed by means of mixed ANOVA, Kendal tau correlations and ordinal (proportional odds) logistic regression. The results show that evening types worked relatively more hours during the evening and night hours compared to morning types as an indication of relative personal fit. Relative personal fit was also found for long shift, short rest, and morning-, evening- and night-shift frequency, but only personal fit related to morning, evening and night-shift was associated with satisfaction with work hours. Reported conflicts at the workplace about work hours and problems with lack of predictability of time for family/leisure activities, was associated with poor satisfaction and a preference for a fixed shift schedule. The present study shows that periodic self-rostering is associated with relative personal fit, in particular with respect to night, evening, and morning work. Personal fit seems to be associated with satisfaction with work hours and may be a moderator of tolerance to shift work exposure.
Influence of atomic densities on propagation property for ultrashort pulses in a two-level medium
NASA Astrophysics Data System (ADS)
Liu, Bingxin; Gong, Shangqing; Song, Xiaohong; Jin, Shiqi
2005-05-01
The influence of atomic densities on the propagation property for ultrashort pulses in a two-level atom (TLA) medium is investigated. With higher atomic densities, the self-induced transparency (SIT) cannot be recovered even for 2? ultrashort pulses. New features such as pulse splitting, red-shift and blue-shift of the corresponding spectra arise, and the component of central frequency gradually disappears.
Retrieval of methanol absorption parameters at terahertz frequencies using multispectral fitting
NASA Astrophysics Data System (ADS)
Slocum, David M.; Xu, Li-Hong; Giles, Robert H.; Goyette, Thomas M.
2015-12-01
A high-resolution broadband study of the methanol absorption spectrum was performed at 1.480-1.495 THz. The transmittance was recorded under both self- and air-broadening conditions for multiple pressures at a resolution of 500 kHz. A multispectral fitting analysis was then performed. The transition frequency, absolute intensity, self- and air-broadening coefficients, and self- and air-induced pressure shifts were retrieved for 221 absorption lines using the multispectral fitting routine. Observed in the data were two different series of transitions, both a b-type Q-branch with K = - 7 ← - 6 and an a-type R-branch with J = 31 ← 30 . The retrieved frequency position values were compared with values from spectral databases and trends within the different series were identified. An analysis of the precision of the fitting routine was also performed.
Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs.
Durán, Vicente; Schnébelin, Cȏme; Guillet de Chatellus, Hugues
2018-05-28
We propose and characterize experimentally a new source of optical frequency combs for performing multi-heterodyne spectrometry. This comb modality is based on a frequency-shifting loop seeded with a continuous-wave (CW) monochromatic laser. The comb lines are generated by successive passes of the CW laser through an acousto-optic frequency shifter. We report the generation of frequency combs with more than 1500 mutually coherent lines, without resorting to non-linear broadening phenomena or external electronic modulation. The comb line spacing is easily reconfigurable from tens of MHz down to the kHz region. We first use a single acousto-optic frequency comb to conduct self-heterodyne interferometry with a high frequency resolution (500 kHz). By increasing the line spacing to 80 MHz, we demonstrate molecular spectroscopy on the sub-millisecond time scale. In order to reduce the detection bandwidth, we subsequently implement an acousto-optic dual-comb spectrometer with the aid of two mutually coherent frequency shifting loops. In each architecture, the potentiality of acousto-optic frequency combs for spectroscopy is validated by spectral measurements of hydrogen cyanide in the near-infrared region.
Coherent multi-heterodyne spectroscopy using acousto-optic frequency combs
NASA Astrophysics Data System (ADS)
Durán, Vicente; Schnébelin, Cȏme; Guillet de Chatellus, Hugues
2018-05-01
We propose and characterize experimentally a new source of optical frequency combs for performing multi-heterodyne spectrometry. This comb modality is based on a frequency shifting loop seeded with a CW monochromatic laser. The comb lines are generated by successive passes of the CW laser through an acousto-optic frequency shifter. We report the generation of frequency combs with more than 1500 mutually coherent lines, without resorting to non-linear broadening phenomena or external electronic modulation. The comb line spacing is easily reconfigurable from tens of MHz down to the kHz region. We first use a single acousto-optic frequency comb to conduct self-heterodyne interferometry with a high frequency resolution (500 kHz). By increasing the line spacing to 80 MHz, we demonstrate molecular spectroscopy on the sub-millisecond time scale. In order to reduce the detection bandwidth, we subsequently implement an acousto-optic dual-comb spectrometer with the aid of two mutually coherent frequency shifting loops. In each architecture, the potentiality of acousto-optic frequency combs for spectroscopy is validated by spectral measurements of hydrogen cyanide in the near-infrared region.
Bassi, Gabriele; Blednykh, Alexei; Smalyuk, Victor
2016-02-24
A novel algorithm for self-consistent simulations of long-range wakefield effects has been developed and applied to the study of both longitudinal and transverse coupled-bunch instabilities at NSLS-II. The algorithm is implemented in the new parallel tracking code space (self-consistent parallel algorithm for collective effects) discussed in the paper. The code is applicable for accurate beam dynamics simulations in cases where both bunch-to-bunch and intrabunch motions need to be taken into account, such as chromatic head-tail effects on the coupled-bunch instability of a beam with a nonuniform filling pattern, or multibunch and single-bunch effects of a passive higher-harmonic cavity. The numericalmore » simulations have been compared with analytical studies. For a beam with an arbitrary filling pattern, intensity-dependent complex frequency shifts have been derived starting from a system of coupled Vlasov equations. The analytical formulas and numerical simulations confirm that the analysis is reduced to the formulation of an eigenvalue problem based on the known formulas of the complex frequency shifts for the uniform filling pattern case.« less
Li, Guicun; Zheng, Yinghui; Ge, Xiaochun; Zeng, Zhinan; Li, Ruxin
2016-08-08
We have experimentally investigated the frequency modulation of high-order harmonics in an orthogonally polarized two-color laser field consisting of a mid-infrared 1800nm fundamental pulse and its second harmonic pulse. It is demonstrated that the high harmonic spectra can be fine-tuned as we slightly change the relative delay of the two-color laser pulses. By analyzing the relative frequency shift of each harmonic at different two-color delays, the nonadiabatic spectral shift induced by the rapid variation of the intensity-dependent intrinsic dipole phase can be distinguished from the blueshift induced by the change of the refractive index during self-phase modulation (SPM). Our comprehensive analysis shows that the frequency modulation pattern is a reflection of the average emission time of high-order harmonic generation (HHG), thus offering a simple method to fine-tune the spectra of the harmonics on a sub-cycle time scale.
Inter-Annual Variability of Soil Moisture Stress Function in the Wheat Field
NASA Astrophysics Data System (ADS)
Akuraju, V. R.; Ryu, D.; George, B.; Ryu, Y.; Dassanayake, K. B.
2014-12-01
Root-zone soil moisture content is a key variable that controls the exchange of water and energy fluxes between land and atmosphere. In the soil-vegetation-atmosphere transfer (SVAT) schemes, the influence of root-zone soil moisture on evapotranspiration (ET) is parameterized by the soil moisture stress function (SSF). Dependence of actual ET: potential ET (fPET) or evaporative fraction to the root-zone soil moisture via SSF can also be used inversely to estimate root-zone soil moisture when fPET is estimated by remotely sensed land surface states. In this work we present fPET versus available soil water (ASW) in the root zone observed in the experimental farm sites in Victoria, Australia in 2012-2013. In the wheat field site, fPET vs ASW exhibited distinct features for different soil depth, net radiation, and crop growth stages. Interestingly, SSF in the wheat field presented contrasting shapes for two cropping years of 2012 and 2013. We argue that different temporal patterns of rainfall (and resulting soil moisture) during the growing seasons in 2012 and 2013 are responsible for the distinctive SSFs. SSF of the wheat field was simulated by the Agricultural Production Systems sIMulator (APSIM). The APSIM was able to reproduce the observed fPET vs. ASW. We discuss implications of our findings for existing modeling and (inverse) remote sensing approaches relying on SSF and alternative growth-stage-dependent SSFs.
Use of self-sensing piezoresistive Si cantilever sensor for determining carbon nanoparticle mass
NASA Astrophysics Data System (ADS)
Wasisto, H. S.; Merzsch, S.; Stranz, A.; Waag, A.; Uhde, E.; Kirsch, I.; Salthammer, T.; Peiner, E.
2011-06-01
A silicon cantilever with slender geometry based Micro Electro Mechanical System (MEMS) for nanoparticles mass detection is presented in this work. The cantilever is actuated using a piezoactuator at the bottom end of the cantilever supporting frame. The oscillation of the microcantilever is detected by a self-sensing method utilizing an integrated full Wheatstone bridge as a piezoresistive strain gauge for signal read out. Fabricated piezoresistive cantilevers of 1.5 mm long, 30 μm wide and 25 μm thick have been employed. This self-sensing cantilever is used due to its simplicity, portability, high-sensitivity and low-cost batch microfabrication. In order to investigate air pollution sampling, a nanoparticles collection test of the piezoresistive cantilever sensor is performed in a sealed glass chamber with a stable carbon aerosol inside. The function principle of cantilever sensor is based on detecting the resonance frequency shift that is directly induced by an additional carbon nanoparticles mass deposited on it. The deposition of particles is enhanced by an electrostatic field. The frequency measurement is performed off-line under normal atmospheric conditions, before and after carbon nanoparticles sampling. The calculated equivalent mass-induced resonance frequency shift of the experiment is measured to be 11.78 +/- 0.01 ng and a mass sensitivity of 8.33 Hz/ng is obtained. The proposed sensor exhibits an effective mass of 2.63 μg, a resonance frequency of 43.92 kHz, and a quality factor of 1230.68 +/- 78.67. These results and analysis indicate that the proposed self-sensing piezoresistive silicon cantilever can offer the necessary potential for a mobile nanoparticles monitor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bassi, Gabriele; Blednykh, Alexei; Smalyuk, Victor
A novel algorithm for self-consistent simulations of long-range wakefield effects has been developed and applied to the study of both longitudinal and transverse coupled-bunch instabilities at NSLS-II. The algorithm is implemented in the new parallel tracking code space (self-consistent parallel algorithm for collective effects) discussed in the paper. The code is applicable for accurate beam dynamics simulations in cases where both bunch-to-bunch and intrabunch motions need to be taken into account, such as chromatic head-tail effects on the coupled-bunch instability of a beam with a nonuniform filling pattern, or multibunch and single-bunch effects of a passive higher-harmonic cavity. The numericalmore » simulations have been compared with analytical studies. For a beam with an arbitrary filling pattern, intensity-dependent complex frequency shifts have been derived starting from a system of coupled Vlasov equations. The analytical formulas and numerical simulations confirm that the analysis is reduced to the formulation of an eigenvalue problem based on the known formulas of the complex frequency shifts for the uniform filling pattern case.« less
Methods and apparatuses for self-generating fault-tolerant keys in spread-spectrum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moradi, Hussein; Farhang, Behrouz; Subramanian, Vijayarangam
Self-generating fault-tolerant keys for use in spread-spectrum systems are disclosed. At a communication device, beacon signals are received from another communication device and impulse responses are determined from the beacon signals. The impulse responses are circularly shifted to place a largest sample at a predefined position. The impulse responses are converted to a set of frequency responses in a frequency domain. The frequency responses are shuffled with a predetermined shuffle scheme to develop a set of shuffled frequency responses. A set of phase differences is determined as a difference between an angle of the frequency response and an angle ofmore » the shuffled frequency response at each element of the corresponding sets. Each phase difference is quantized to develop a set of secret-key quantized phases and a set of spreading codes is developed wherein each spreading code includes a corresponding phase of the set of secret-key quantized phases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Favata, Marc
2011-01-15
The innermost stable circular orbit (ISCO) delimits the transition from circular orbits to those that plunge into a black hole. In the test-mass limit, well-defined ISCO conditions exist for the Kerr and Schwarzschild spacetimes. In the finite-mass case, there are a large variety of ways to define an ISCO in a post-Newtonian (PN) context. Here I generalize the gauge-invariant ISCO condition of Blanchet and Iyer [Classical Quantum Gravity 20, 755 (2003)] to the case of spinning (nonprecessing) binaries. The Blanchet-Iyer ISCO condition has two desirable and unexpected properties: (1) it exactly reproduces the Schwarzschild ISCO in the test-mass limit, andmore » (2) it accurately approximates the recently calculated shift in the Schwarzschild ISCO frequency due to the conservative-piece of the gravitational self-force [L. Barack and N. Sago, Phys. Rev. Lett. 102, 191101 (2009)]. The generalization of this ISCO condition to spinning binaries has the property that it also exactly reproduces the Kerr ISCO in the test-mass limit (up to the order at which PN spin corrections are currently known). The shift in the ISCO due to the spin of the test-particle is also calculated. Remarkably, the gauge-invariant PN ISCO condition exactly reproduces the ISCO shift predicted by the Papapetrou equations for a fully relativistic spinning particle. It is surprising that an analysis of the stability of the standard PN equations of motion is able (without any form of 'resummation') to accurately describe strong-field effects of the Kerr spacetime. The ISCO frequency shift due to the conservative self-force in Kerr is also calculated from this new ISCO condition, as well as from the effective-one-body Hamiltonian of Barausse and Buonanno [Phys. Rev. D 81, 084024 (2010)]. These results serve as a useful point of comparison for future gravitational self-force calculations in the Kerr spacetime.« less
Composite pulsed field gradients with refocused chemical shifts and short recovery time.
Hu, H; Shaka, A J
1999-01-01
An improved self-compensating pulsed field gradient (PFG) technique that combines antiphase gradient pairs with broadband frequency-modulated 180 degrees pulses is proposed. The antiphase gradient pairs lead to superb system recovery. In addition, evolution under chemical shift and heteronuclear J coupling are refocused during the PFG, making it appear effectively instantaneous. This new approach makes it possible to obtain high-resolution phase-sensitive 2D spectra for the PFG version of many experiments such as COSY, DQF-COSY, and HSQC without adding extra compensating delays or pulses. While reasonable suppression of unwanted magnetization is achieved, this method also gives satisfactory retention of desired signals. As a bonus, the field-frequency lock is not perturbed during the experiments. Copyright 1999 Academic Press.
Extended Coherence Time on the Clock Transition of Optically Trapped Rubidium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleine Buening, G.; Will, J.; Ertmer, W.
2011-06-17
Optically trapped ensembles are of crucial importance for frequency measurements and quantum memories but generally suffer from strong dephasing due to inhomogeneous density and light shifts. We demonstrate a drastic increase of the coherence time to 21 s on the magnetic field insensitive clock transition of {sup 87}Rb by applying the recently discovered spin self-rephasing [C. Deutsch et al., Phys. Rev. Lett. 105, 020401 (2010)]. This result confirms the general nature of this new mechanism and thus shows its applicability in atom clocks and quantum memories. A systematic investigation of all relevant frequency shifts and noise contributions yields a stabilitymore » of 2.4x10{sup -11{tau}-1/2}, where {tau} is the integration time in seconds. Based on a set of technical improvements, the presented frequency standard is predicted to rival the stability of microwave fountain clocks in a potentially much more compact setup.« less
NASA Astrophysics Data System (ADS)
Illas, F.; Zurita, S.; Márquez, A. M.; Rubio, J.
1997-04-01
The chemisorption of CO on the atop site of Pt(111) has been simulated by a Pt4 cluster model. Ab initio self consistent field (SCF) and complete active space self consistent field (CASSCF) cluster model wave functions have been obtained for the electronic ground state. Likewise, ab initio SCF wavefunctions have been obtained for two other electronic states. The optimum geometry and vibrational frequencies of chemisorbed CO are reported for the three states. The interaction energy and vibrational shift of chemisorbed CO, with respect to free gas phase CO, have been analyzed for the three electronic states. This analysis is carried out by means of the constrained space orbital variation (CSOV) method. In all cases the bond is found to be dominated by σ donation and π back-donation, known as Blyholder's mechanism. This mechanism is further supported by SCF calculations on a larger, Pt13, cluster model. For both clusters, the CSOV analysis of the vibrational frequency definitely shows that, contrary to previous recent studies, a major contribution to the experimentally observed vibrational shift comes from the π back-donation mechanism. However, we found that, contrary to common belief, σ donation also acts to lower the CO frequency and not to increase it. Physical reasons for such unexpected behaviour are given.
NASA Astrophysics Data System (ADS)
Sturesson, P.; Khaji, Z.; Knaust, S.; Sundqvist, J.; Klintberg, L.; Thornell, G.
2013-12-01
This paper reports on the design, manufacturing and evaluation of a small, wirelessly powered and read resonating antenna circuit with an integrated pressure sensor. The work aims at developing miniature devices suitable for harsh environments, where high temperature prevents the use of conventional, silicon-based microdevices. Here, the device is made of alumina with platinum as conducting material. Ceramic green tapes were structured using high-precision milling, metallized using screen printing, and subsequently laminated to form stacks before they were sintered. The device's frequency shift as a function of temperature was studied up to 900°C. The contributions to the shift both from the thermomechanical deformation of the device at large, and from the integrated and, so far, self-pressurized sensor were sorted out. A total frequency shift of 3200 ppm was observed for the pressure sensor for heating over the whole range. Negligible levels of thermally induced radius of curvature were observed. With three-point bending, a frequency shift of 180 ppm was possible to induce with a curvature of radius of 220 m at a 10 N load. The results indicate that a robust pressure sensor node, which can register pressure changes of a few bars at 900°C and wirelessly transmit the signal, is viable.
Carrier-separating demodulation of phase shifting self-mixing interferometry
NASA Astrophysics Data System (ADS)
Tao, Yufeng; Wang, Ming; Xia, Wei
2017-03-01
A carrier separating method associated with noise-elimination had been introduced into a sinusoidal phase-shifting self-mixing interferometer. The conventional sinusoidal phase shifting self-mixing interferometry was developed into a more competitive instrument with high computing efficiency and nanometer accuracy of λ / 100 in dynamical vibration measurement. The high slew rate electro-optic modulator induced a sinusoidal phase carrier with ultralow insertion loss in this paper. In order to extract phase-shift quickly and precisely, this paper employed the carrier-separating to directly generate quadrature signals without complicated frequency domain transforms. Moreover, most noises were evaluated and suppressed by a noise-elimination technology synthesizing empirical mode decomposition with wavelet transform. The overall laser system was described and inherent advantages such as high computational efficiency and decreased nonlinear errors of the established system were demonstrated. The experiment implemented on a high precision PZT (positioning accuracy was better than 1 nm) and compared with laser Doppler velocity meter. The good agreement of two instruments shown that the short-term resolution had improved from 10 nm to 1.5 nm in dynamic vibration measurement with reduced time expense. This was useful in precision measurement to improve the SMI with same sampling rate. The proposed signal processing was performed in pure time-domain requiring no preprocessing electronic circuits.
Fitzgerald, Matthew; Sagi, Elad; Morbiwala, Tasnim A.; Tan, Chin-Tuan; Svirsky, Mario A.
2013-01-01
Objectives Perception of spectrally degraded speech is particularly difficult when the signal is also distorted along the frequency axis. This might be particularly important for post-lingually deafened recipients of cochlear implants (CI), who must adapt to a signal where there may be a mismatch between the frequencies of an input signal and the characteristic frequencies of the neurons stimulated by the CI. However, there is a lack of tools that can be used to identify whether an individual has adapted fully to a mismatch in the frequency-to-place relationship and if so, to find a frequency table that ameliorates any negative effects of an unadapted mismatch. The goal of the proposed investigation is to test the feasibility of whether real-time selection of frequency tables can be used to identify cases in which listeners have not fully adapted to a frequency mismatch. The assumption underlying this approach is that listeners who have not adapted to a frequency mismatch will select a frequency table that minimizes any such mismatches, even at the expense of reducing the information provided by this frequency table. Design 34 normal-hearing adults listened to a noise-vocoded acoustic simulation of a cochlear implant and adjusted the frequency table in real time until they obtained a frequency table that sounded “most intelligible” to them. The use of an acoustic simulation was essential to this study because it allowed us to explicitly control the degree of frequency mismatch present in the simulation. None of the listeners had any previous experience with vocoded speech, in order to test the hypothesis that the real-time selection procedure could be used to identify cases in which a listener has not adapted to a frequency mismatch. After obtaining a self-selected table, we measured CNC word-recognition scores with that self-selected table and two other frequency tables: a “frequency-matched” table that matched the analysis filters with the noisebands of the noise-vocoder simulation, and a “right information” table that is similar to that used in most cochlear implant speech processors, but in this simulation results in a frequency shift equivalent to 6.5 mm of cochlear space. Results Listeners tended to select a table that was very close to, but shifted slightly lower in frequency from the frequency-matched table. The real-time selection process took on average 2–3 minutes for each trial, and the between-trial variability was comparable to that previously observed with closely-related procedures. The word-recognition scores with the self-selected table were clearly higher than with the right-information table and slightly higher than with the frequency-matched table. Conclusions Real-time self-selection of frequency tables may be a viable tool for identifying listeners who have not adapted to a mismatch in the frequency-to-place relationship, and to find a frequency table that is more appropriate for them. Moreover, the small but significant improvements in word-recognition ability observed with the self-selected table suggest that these listeners based their selections on intelligibility rather than some other factor. The within-subject variability in the real-time selection procedure was comparable to that of a genetic algorithm, and the speed of the real-time procedure appeared to be faster than either a genetic algorithm or a simplex procedure. PMID:23807089
Spectral changes induced by a phase modulator acting as a time lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plansinis, B. W.; Donaldson, W. R.; Agrawal, G. P.
2015-07-06
We show both numerically and experimentally that a phase modulator, acting as a time lens in the Fourier-lens configuration, can induce spectral broadening, narrowing, or shifts, depending on the phase of the modulator cycle. These spectral effects depend on the maximum phase shift that can be imposed by the modulator. In our numerical simulations, pulse spectrum could be compressed by a factor of 8 for a 30 rad phase shift. Experimentally, spectral shifts over a 1.35 nm range and spectral narrowing and broadening by a factor of 2 were demonstrated using a lithium niobate phase modulator with a maximum phasemore » shift of 16 rad at a 10 GHz modulation frequency. All spectral changes were accomplished without employing optical nonlinear effects such as self- or cross-phase modulation.« less
Yu, Aifang; Chen, Xiangyu; Wang, Rui; Liu, Jingyu; Luo, Jianjun; Chen, Libo; Zhang, Yang; Wu, Wei; Liu, Caihong; Yuan, Hongtao; Peng, Mingzeng; Hu, Weiguo; Zhai, Junyi; Wang, Zhong Lin
2016-04-26
In this paper, we demonstrate an application of a triboelectric nanogenerator (TENG) as a self-powered communication unit. An elaborately designed TENG is used to translate a series of environmental triggering signals into binary digital signals and drives an electronic-optical device to transmit binary digital data in real-time without an external power supply. The elaborately designed TENG is built in a membrane structure that can effectively drive the electronic-optical device in a bandwidth from 1.30 to 1.65 kHz. Two typical communication modes (amplitude-shift keying and frequency-shift keying) are realized through the resonant response of TENG to different frequencies, and two digital signals, i.e., "1001" and "0110", are successfully transmitted and received through this system, respectively. Hence, in this study, a simple but efficient method for directly transmitting ambient vibration to the receiver as a digital signal is established using an elaborately designed TENG and an optical communication technique. This type of the communication system, as well as the implementation method presented, exhibits great potential for applications in the smart city, smart home, password authentication, and so on.
Detection of Non-Symmetrical Damage in Smart Plate-Like Structures
NASA Technical Reports Server (NTRS)
Blanks, H. T.; Emeric, P. R.
1998-01-01
A two-dimensional model for in-plane vibrations of a cantilever plate with a non-symmetrical damage is used in the context of defect identification in materials with piezoelectric ceramic patches bonded to their surface. These patches can act both as actuators and sensors in a self-analyzing fashion, which is a characteristic of smart materials. A Galerkin method is used to approximate the dynamic response of these structures. The natural frequency shifts due to the damage are estimated numerically and compared to experimental data obtained from tests on cantilever aluminum plate-like structures damaged at different locations with defects of different depths. The damage location and extent are determined by an enhanced least square identification method. Efficacy of the frequency shift based algorithms is demonstrated using experimental data.
NASA Astrophysics Data System (ADS)
Smetanin, I. V.; Erokhin, A. I.; Baranov, A. N.
2018-07-01
We report the results of the experimental and theoretical study of stimulated temperature scattering in toluene and hexane solutions of Ag-nanoparticles, as well as in pure toluene in the two-photon absorption regime. A four-wave mixing scheme with two counter-propagating pump waves of the same frequency is utilised to demonstrate the lasing effect and the amplification of the backscattered anti-Stokes signal. For the first time, we have measured anti-Stokes spectral shifts which turn out to appreciably exceed the Rayleigh line widths in those liquids. It is shown that the amplification effect is provided predominantly by thermally induced coherent polarisation oscillations, while the dynamic interference temperature grating causes the formation of a self-induced optical cavity inside the interaction region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bora, B., E-mail: bbora@cchen.cl
2015-10-15
On the basis of nonlinear global model, a dual frequency capacitively coupled radio frequency plasma driven by 13.56 MHz and 27.12 MHz has been studied to investigate the influences of driving voltages on the generation of dc self-bias and plasma heating. Fluid equations for the ions inside the plasma sheath have been considered to determine the voltage-charge relations of the plasma sheath. Geometrically symmetric as well as asymmetric cases with finite geometrical asymmetry of 1.2 (ratio of electrodes area) have been considered to make the study more reasonable to experiment. The electrical asymmetry effect (EAE) and finite geometrical asymmetry is found tomore » work differently in controlling the dc self-bias. The amount of EAE has been primarily controlled by the phase angle between the two consecutive harmonics waveforms. The incorporation of the finite geometrical asymmetry in the calculations shift the dc self-bias towards negative polarity direction while increasing the amount of EAE is found to increase the dc self-bias in either direction. For phase angle between the two waveforms ϕ = 0 and ϕ = π/2, the amount of EAE increases significantly with increasing the low frequency voltage, whereas no such increase in the amount of EAE is found with increasing high frequency voltage. In contrast to the geometrically symmetric case, where the variation of the dc self-bias with driving voltages for phase angle ϕ = 0 and π/2 are just opposite in polarity, the variation for the geometrically asymmetric case is different for ϕ = 0 and π/2. In asymmetric case, for ϕ = 0, the dc self-bias increases towards the negative direction with increasing both the low and high frequency voltages, but for the ϕ = π/2, the dc-self bias is increased towards positive direction with increasing low frequency voltage while dc self-bias increases towards negative direction with increasing high frequency voltage.« less
Brennan, Adrian C; Hiscock, Simon J
2010-04-01
Allopolyploid speciation is common in plants and is frequently associated with shifts from outcrossing, for example self-incompatibility, to inbreeding (i.e. selfing). Senecio cambrensis is a recently evolved allohexaploid species that formed following hybridization between diploid self-incompatible S. squalidus and tetraploid self-compatible S. vulgaris. Studies of reproduction in wild populations of S. cambrensis have concluded that it is self-compatible. Here, we investigated self-compatibility in synthetic lines of S. cambrensis generated via hybridization and colchicine-induced polyploidization and wild S. cambrensis using controlled crossing experiments. Synthetic F(1)S. cambrensis individuals were all self-compatible but, in F(2) and later generations, self-incompatible individuals were identified at frequencies of 6.7-9.2%. Self-incompatibility was also detected in wild sampled individuals at a frequency of 12.2%. The mechanism and genetics of self-incompatibility were tested in synthetic S. cambrensis and found to be similar to those of its paternal parent S. squalidus (i.e. sporophytic). These results show, for the first time, that functional sporophytic self-incompatibility can be inherited and expressed in allopolyploids as early as the second (F(2)) generation. Wild S. cambrensis should therefore be considered as possessing a mixed mating system with the potential for evolution towards either inbreeding or outcrossing.
NASA Astrophysics Data System (ADS)
Schroeder, Paul J.; Cich, Matthew J.; Yang, Jinyu; Giorgetta, Fabrizio R.; Swann, William C.; Coddington, Ian; Newbury, Nathan R.; Drouin, Brian J.; Rieker, Gregory B.
2018-05-01
We measure speed-dependent Voigt lineshape parameters with temperature-dependence exponents for several hundred spectroscopic features of pure water spanning 6801-7188 cm-1. The parameters are extracted from broad bandwidth, high-resolution dual frequency comb absorption spectra with multispectrum fitting techniques. The data encompass 25 spectra ranging from 296 K to 1305 K and 1 to 17 Torr of pure water vapor. We present the extracted parameters, compare them to published data, and present speed-dependence, self-shift, and self-broadening temperature-dependent parameters for the first time. Lineshape data is extracted using a quadratic speed-dependent Voigt profile and a single self-broadening power law temperature-dependence exponent over the entire temperature range. The results represent an important step toward a new high-temperature database using advanced lineshape profiles.
Energetic-particle-modified global Alfvén eigenmodes
NASA Astrophysics Data System (ADS)
Lestz, J. B.; Belova, E. V.; Gorelenkov, N. N.
2018-04-01
Fully self-consistent hybrid MHD/particle simulations reveal strong energetic particle modifications to sub-cyclotron global Alfvén eigenmodes (GAEs) in low-aspect ratio, NSTX-like conditions. Key parameters defining the fast ion distribution function—the normalized injection velocity v0/vA and central pitch—are varied in order to study their influence on the characteristics of the excited modes. It is found that the frequency of the most unstable mode changes significantly and continuously with beam parameters, in accordance with the Doppler-shifted cyclotron resonances which drive the modes, and depending most substantially on v0/vA . This unexpected result is present for both counter-propagating GAEs, which are routinely excited in NSTX, and high frequency co-GAEs, which have not been previously studied. Large changes in frequency without clear corresponding changes in the mode structure are signatures of an energetic particle mode, referred to here as an energetic-particle-modified GAE. Additional simulations conducted for a fixed MHD equilibrium demonstrate that the GAE frequency shift cannot be explained by the equilibrium changes due to energetic particle effects.
Energetic-particle-modified global Alfven eigenmodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lestz, J. B.; Belova, E. V.; Gorelenkov, N. N.
Fully self-consistent hybrid MHD/particle simulations reveal strong energetic particle modifications to sub-cyclotron global Alfvén eigenmodes (GAEs) in low-aspect ratio, NSTX-like conditions. Key parameters defining the fast ion distribution function—the normalized injection velocity v 0/v A and central pitch—are varied in order to study their influence on the characteristics of the excited modes. It is found that the frequency of the most unstable mode changes significantly and continuously with beam parameters, in accordance with the Doppler-shifted cyclotron resonances which drive the modes, and depending most substantially on v 0/v A. This unexpected result is present for both counter-propagating GAEs, which aremore » routinely excited in NSTX, and high frequency co-GAEs, which have not been previously studied. Large changes in frequency without clear corresponding changes in the mode structure are signatures of an energetic particle mode, referred to here as an energetic-particle-modified GAE. In conclusion, additional simulations conducted for a fixed MHD equilibrium demonstrate that the GAE frequency shift cannot be explained by the equilibrium changes due to energetic particle effects.« less
Energetic-particle-modified global Alfven eigenmodes
Lestz, J. B.; Belova, E. V.; Gorelenkov, N. N.
2018-04-30
Fully self-consistent hybrid MHD/particle simulations reveal strong energetic particle modifications to sub-cyclotron global Alfvén eigenmodes (GAEs) in low-aspect ratio, NSTX-like conditions. Key parameters defining the fast ion distribution function—the normalized injection velocity v 0/v A and central pitch—are varied in order to study their influence on the characteristics of the excited modes. It is found that the frequency of the most unstable mode changes significantly and continuously with beam parameters, in accordance with the Doppler-shifted cyclotron resonances which drive the modes, and depending most substantially on v 0/v A. This unexpected result is present for both counter-propagating GAEs, which aremore » routinely excited in NSTX, and high frequency co-GAEs, which have not been previously studied. Large changes in frequency without clear corresponding changes in the mode structure are signatures of an energetic particle mode, referred to here as an energetic-particle-modified GAE. In conclusion, additional simulations conducted for a fixed MHD equilibrium demonstrate that the GAE frequency shift cannot be explained by the equilibrium changes due to energetic particle effects.« less
Apparatus and method for monitoring the presence of a conductive media
DuVall, Bruce W.; Valentine, James W.; Morey, Kenneth O.
1979-01-01
An inductive level sensor has inductively coupled primary and secondary windings. Circuitry drives the primary with an AC signal of constant current magnitude and selected frequency f to induce in the secondary, a voltage signal V of magnitude .vertline.V.vertline., frequency f and phase difference .phi. from the driving signal. Circuitry operates to generate a voltage output signal proportional to .vertline.V.vertline. cos (.phi.-.theta.), where .theta. is a selectively set phase shift factor. By properly and selectively adjusting the frequency f and phase shift factor .theta., an output signal .vertline.V.vertline. cos (.phi.-.theta.) can be provided which self-compensates for changes in mutual inductance caused by operating temperature variations so that an output signal is produced which is substantially linearly proportional to changes in the level of a pool of liquid metal being monitored. Disclosed also is calibration circuitry and circuitry for converting the voltage signal .vertline.V.vertline. cos (.phi.-.theta.) into a current signal.
A Signature of Self-Organized Criticality in the HT-6M Edge Plasma Turbulence
NASA Astrophysics Data System (ADS)
Wang, Wen-Hao; Yu, Chang-Xuan; Wen, Yi-Zhi; Xu, Yu-Hong; Ling, Bi-Li; Gong, Xian-Zu; Liu, Bao-Hua; Wan, Bao-Nian
2001-03-01
Power spectra of electron density and floating potential fluctuations in the velocity shear layer of the HT-6M edge region have been measured and analysed. All the spectra have three distinct frequency regions with the spectral decay indices typical of self-organized criticality systems (0, -1 and -4) when Doppler shift effects induced by the plasma E×B flow velocity have been taken into account. These results are consistent with the predictions of the self-organized criticality models, which may be an indication of edge plasma turbulence in the HT-6M tokamak evolving into a critical state independent of local plasma parameters.
Sleep, sleepiness and health complaints in police officers: the effects of a flexible shift system.
Eriksen, Claire Anne; Kecklund, Göran
2007-04-01
The aim of the study was to study the effects of a flexible shift system (based on self-determined work hours) with respect to sleep/wake complaints and subjective health. The comparison group was a rapidly rotating shift system, with frequently occurring quick returns. A secondary aim was to examine the relation between work hour characteristics indicating compressed or difficult rosters (e.g. number of workdays in a row, frequency of quick returns and long work shifts) and subjective sleep and sleepiness, within the flexible shift system group. The sample of the analysis included 533 randomly selected police officers, of which 26% were females. The participants answered a questionnaire. The results showed that the flexible shift system group did not differ with respect to sleep/wake complaints and subjective health. However, the flexible shift group obtained more sleep in connection with the shifts, probably because of longer rest time between shifts. Thus, they worked less quick returns and long work shifts. The association between work hour characteristics and sleep/wake complaints was weak in the flexible shift group. Instead, sleep/wake problems were mainly associated with the attitude to work hours.
Vacuum Bloch-Siegert shift in Landau polaritons with ultra-high cooperativity
NASA Astrophysics Data System (ADS)
Li, Xinwei; Bamba, Motoaki; Zhang, Qi; Fallahi, Saeed; Gardner, Geoff C.; Gao, Weilu; Lou, Minhan; Yoshioka, Katsumasa; Manfra, Michael J.; Kono, Junichiro
2018-06-01
A two-level system resonantly interacting with an a.c. magnetic or electric field constitutes the physical basis of diverse phenomena and technologies. However, Schrödinger's equation for this seemingly simple system can be solved exactly only under the rotating-wave approximation, which neglects the counter-rotating field component. When the a.c. field is sufficiently strong, this approximation fails, leading to a resonance-frequency shift known as the Bloch-Siegert shift. Here, we report the vacuum Bloch-Siegert shift, which is induced by the ultra-strong coupling of matter with the counter-rotating component of the vacuum fluctuation field in a cavity. Specifically, an ultra-high-mobility two-dimensional electron gas inside a high-Q terahertz cavity in a quantizing magnetic field revealed ultra-narrow Landau polaritons, which exhibited a vacuum Bloch-Siegert shift up to 40 GHz. This shift, clearly distinguishable from the photon-field self-interaction effect, represents a unique manifestation of a strong-field phenomenon without a strong field.
Work stress, premenstrual syndrome and dysphoric disorder: are there any associations?
Namavar Jahromi, B; Pakmehr, S; Hagh-Shenas, H
2011-03-01
Women with recurrent and severe symptoms are diagnosed as having premenstrual syndrome (PMS), and if they suffer from severe affective symptoms, a diagnosis of premenstrual dysphoric disorder (PMDD) is made. The purpose of this study was to determine the association of work stress with PMS and PMDD. Fifty-five female medical students in their internship program (ten 24-hour shifts per month) and 38 third-year female medical students without any shift duties were asked to participate in this study. A questionnaire was used to record demographic information and a self-report inventory was used to measure 13 symptoms relevant to PMS and PMDD according to DSM-IV criteria. All participants were asked to complete the inventory every night around midnight for those on shifts or before going to bed at home for 60 consecutive nights. Out of 55 volunteers in the shift-work group, 31 (56%) fulfilled the diagnostic criteria for PMS in contrast to 12 (32%) in the control group. The frequency of PMDD was 12 (22%) in the intern group and 5 (13%) in the control group. Twenty one students (55%) from the control group did not have PMS or PMDD, compared to 12 (22%) students from the shift workers. Decreased energy (70.9%) and irritability (65.4%) were the most frequent symptoms during the luteal phase in the shift-work group. Work stress and an increase in responsibility may produce or exacerbate PMS. Self-help approaches to induce self-awareness, along with psychological and psychiatric interventions, may help susceptible women to overcome this cyclic condition in order to increase their productivity as well as their quality of life.
Low-coherence interferometric tip-clearance probe
NASA Astrophysics Data System (ADS)
Kempe, Andreas; Schlamp, Stefan; Rösgen, Thomas; Haffner, Ken
2003-08-01
We propose an all-fiber, self-calibrating, economical probe that is capable of near-real-time, single-port, simultaneous blade-to-blade tip-clearance measurements with submillimeter accuracy (typically <100 μm, absolute) in the first stages of a gas turbine. Our probe relies on the interference between backreflected light from the blade tips during the 1-μs blade passage time and a frequency-shifted reference with variable time delay, making use of a low-coherence light source. A single optical fiber of arbitrary length connects the self-contained optics and electronics to the turbine.
Characterization of un-irradiated MIMAS MOX fuel by Raman spectroscopy and EPMA
NASA Astrophysics Data System (ADS)
Talip, Zeynep; Peuget, Sylvain; Magnin, Magali; Tribet, Magaly; Valot, Christophe; Vauchy, Romain; Jégou, Christophe
2018-02-01
In this study, Raman spectroscopy technique was implemented to characterize un-irradiated MIMAS (MIcronized - MASter blend) MOX fuel samples with average 7 wt.% Pu content and different damage levels, 13 years after fabrication, one year after thermal recovery and soon after annealing, respectively. The impacts of local Pu content, deviation from stoichiometry and self-radiation damage on Raman spectrum of the studied MIMAS MOX samples were assessed. MIMAS MOX fuel has three different phases Pu-rich agglomerate, coating phase and uranium matrix. In order to distinguish these phases, Raman results were associated with Pu content measurements performed by Electron Microprobe Analysis. Raman results show that T2g frequency significantly shifts from 445 to 453 cm-1 for Pu contents increasing from 0.2 to 25 wt.%. These data are satisfactorily consistent with the calculations obtained with Gruneisen parameters. It was concluded that the position of the T2g band is mainly controlled by Pu content and self-radiation damage. Deviation from stoichiometry does not have a significant influence on T2g band position. Self-radiation damage leads to a shift of T2g band towards lower frequency (∼1-2 cm-1 for the UO2 matrix of damaged sample). However, this shift is difficult to quantify for the coating phase and Pu agglomerates given the dispersion of high Pu concentrations. In addition, 525 cm-1 band, which was attributed to sub-stoichiometric structural defects, is presented for the first time for the self-radiation damaged MOX sample. Thanks to the different oxidation resistance of each phase, it was shown that laser induced oxidation could be alternatively used to identify the phases. It is demonstrated that micro-Raman spectroscopy is an efficient technique for the characterization of heterogeneous MOX samples, due to its low spatial resolution.
Self-Consistent Optimization of Excited States within Density-Functional Tight-Binding.
Kowalczyk, Tim; Le, Khoa; Irle, Stephan
2016-01-12
We present an implementation of energies and gradients for the ΔDFTB method, an analogue of Δ-self-consistent-field density functional theory (ΔSCF) within density-functional tight-binding, for the lowest singlet excited state of closed-shell molecules. Benchmarks of ΔDFTB excitation energies, optimized geometries, Stokes shifts, and vibrational frequencies reveal that ΔDFTB provides a qualitatively correct description of changes in molecular geometries and vibrational frequencies due to excited-state relaxation. The accuracy of ΔDFTB Stokes shifts is comparable to that of ΔSCF-DFT, and ΔDFTB performs similarly to ΔSCF with the PBE functional for vertical excitation energies of larger chromophores where the need for efficient excited-state methods is most urgent. We provide some justification for the use of an excited-state reference density in the DFTB expansion of the electronic energy and demonstrate that ΔDFTB preserves many of the properties of its parent ΔSCF approach. This implementation fills an important gap in the extended framework of DFTB, where access to excited states has been limited to the time-dependent linear-response approach, and affords access to rapid exploration of a valuable class of excited-state potential energy surfaces.
Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping
NASA Technical Reports Server (NTRS)
English, T. C.; Jechart, E.; Kwon, T. M.
1978-01-01
Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).
Accurate deuterium spectroscopy for fundamental studies
NASA Astrophysics Data System (ADS)
Wcisło, P.; Thibault, F.; Zaborowski, M.; Wójtewicz, S.; Cygan, A.; Kowzan, G.; Masłowski, P.; Komasa, J.; Puchalski, M.; Pachucki, K.; Ciuryło, R.; Lisak, D.
2018-07-01
We present an accurate measurement of the weak quadrupole S(2) 2-0 line in self-perturbed D2 and theoretical ab initio calculations of both collisional line-shape effects and energy of this rovibrational transition. The spectra were collected at the 247-984 Torr pressure range with a frequency-stabilized cavity ring-down spectrometer linked to an optical frequency comb (OFC) referenced to a primary time standard. Our line-shape modeling employed quantum calculations of molecular scattering (the pressure broadening and shift and their speed dependencies were calculated, while the complex frequency of optical velocity-changing collisions was fitted to experimental spectra). The velocity-changing collisions are handled with the hard-sphere collisional kernel. The experimental and theoretical pressure broadening and shift are consistent within 5% and 27%, respectively (the discrepancy for shift is 8% when referred not to the speed averaged value, which is close to zero, but to the range of variability of the speed-dependent shift). We use our high pressure measurement to determine the energy, ν0, of the S(2) 2-0 transition. The ab initio line-shape calculations allowed us to mitigate the expected collisional systematics reaching the 410 kHz accuracy of ν0. We report theoretical determination of ν0 taking into account relativistic and QED corrections up to α5. Our estimation of the accuracy of the theoretical ν0 is 1.3 MHz. We observe 3.4σ discrepancy between experimental and theoretical ν0.
Quadrature-quadrature phase-shift keying
NASA Astrophysics Data System (ADS)
Saha, Debabrata; Birdsall, Theodore G.
1989-05-01
Quadrature-quadrature phase-shift keying (Q2PSK) is a spectrally efficient modulation scheme which utilizes available signal space dimensions in a more efficient way than two-dimensional schemes such as QPSK and MSK (minimum-shift keying). It uses two data shaping pulses and two carriers, which are pairwise quadrature in phase, to create a four-dimensional signal space and increases the transmission rate by a factor of two over QPSK and MSK. However, the bit error rate performance depends on the choice of pulse pair. With simple sinusoidal and cosinusoidal data pulses, the Eb/N0 requirement for Pb(E) = 10 to the -5 is approximately 1.6 dB higher than that of MSK. Without additional constraints, Q2PSK does not maintain constant envelope. However, a simple block coding provides a constant envelope. This coded signal substantially outperforms MSKS and TFM (time-frequency multiplexing) in bandwidth efficiency. Like MSK, Q2PSK also has self-clocking and self-synchronizing ability. An optimum class of pulse shapes for use in Q2PSK-format is presented. One suboptimum realization achieves the Nyquist rate of 2 bits/s/Hz using binary detection.
NASA Astrophysics Data System (ADS)
Ju, Yonglin; Jiang, Yan; Zhou, Yuan
A dynamic experimental apparatus was designed and constructed to investigate oscillating flow characteristics in a regenerator subjected to a periodically reversing flow established by means of a self-made linear compressor. Detailed experimental data of oscillating pressure drops and phase shift characteristics for regenerators in a high frequency pulse tube cryocooler with an operating frequency of 50 Hz were given. The correlation equations for the maximum and cycle-averaged friction factors in terms of Reynolds numbers and dimensionless distance X were obtained. It was found that the value of the cycle-averaged pressure drop in the oscillating flow across the regenerator is two to three times higher than that of a steady flow at the same Reynolds numbers based on the cross-sectional mean velocity. In addition, the relationship of the phase shifts between the velocity and pressure wave is also discussed.
Dual-domain lateral shearing interferometer
Naulleau, Patrick P.; Goldberg, Kenneth Alan
2004-03-16
The phase-shifting point diffraction interferometer (PS/PDI) was developed to address the problem of at-wavelength metrology of extreme ultraviolet (EUV) optical systems. Although extremely accurate, the fact that the PS/PDI is limited to use with coherent EUV sources, such as undulator radiation, is a drawback for its widespread use. An alternative to the PS/PDI, with relaxed coherence requirements, is lateral shearing interferometry (LSI). The use of a cross-grating, carrier-frequency configuration to characterize a large-field 4.times.-reduction EUV lithography optic is demonstrated. The results obtained are directly compared with PS/PDI measurements. A defocused implementation of the lateral shearing interferometer in which an image-plane filter allows both phase-shifting and Fourier wavefront recovery. The two wavefront recovery methods can be combined in a dual-domain technique providing suppression of noise added by self-interference of high-frequency components in the test-optic wavefront.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haga, Takafumi; Doi, Akihiro; Murata, Yasuhiro
2015-07-01
We report multifrequency phase-referenced observations of the nearby radio galaxy NGC 4261, which has prominent two-sided jets, using the Very Long Baseline Array at 1.4–43 GHz. We measured radio core positions showing observing frequency dependences (known as “core shift”) in both approaching jets and counterjets. The limit of the core position as the frequency approaches infinity, which suggests a jet base, is separated by 82 ± 16 μas upstream in projection, corresponding to (310 ± 60)R{sub s} (R{sub s}: Schwarzschild radius) as a deprojected distance, from the 43 GHz core in the approaching jet. In addition, the innermost component atmore » the counterjet side appeared to approach the same position at infinity of the frequency, indicating that cores on both sides are approaching the same position, suggesting a spatial coincidence with the central engine. Applying a phase-referencing technique, we also obtained spectral index maps, which indicate that emission from the counterjet is affected by free–free absorption (FFA). The result of the core shift profile on the counterjet also requires FFA because the core positions at 5–15 GHz cannot be explained by a simple core shift model based on synchrotron self-absorption (SSA). Our result is apparently consistent with the SSA core shift with an additional disk-like absorber over the counterjet side. Core shift and opacity profiles at the counterjet side suggest a two-component accretion: a radiatively inefficient accretion flow at the inner region and a truncated thin disk in the outer region. We proposed a possible solution about density and temperature profiles in the outer disk on the basis of the radio observation.« less
Fitzgerald, Matthew B.; Prosolovich, Ksenia; Tan, Chin-Tuan; Glassman, E. Katelyn; Svirsky, Mario A.
2017-01-01
Background Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. Purpose The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. Research Design A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. Study Sample A total of 31 normal-hearing young adults participated in this study. Data Collection and Analysis Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. Results Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. Conclusions Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a “most intelligible” frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition. PMID:28534729
Self-referenced locking of optical coherence by single-detector electronic-frequency tagging
NASA Astrophysics Data System (ADS)
Shay, T. M.; Benham, Vincent; Spring, Justin; Ward, Benjamin; Ghebremichael, F.; Culpepper, Mark A.; Sanchez, Anthony D.; Baker, J. T.; Pilkington, D.; Berdine, Richard
2006-02-01
We report a novel coherent beam combining technique. This is the first actively phase locked optical fiber array that eliminates the need for a separate reference beam. In addition, only a single photodetector is required. The far-field central spot of the array is imaged onto the photodetector to produce the phase control loop signals. Each leg of the fiber array is phase modulated with a separate RF frequency, thus tagging the optical phase shift for each leg by a separate RF frequency. The optical phase errors for the individual array legs are separated in the electronic domain. In contrast with the previous active phase locking techniques, in our system the reference beam is spatially overlapped with all the RF modulated fiber leg beams onto a single detector. The phase shift between the optical wave in the reference leg and in the RF modulated legs is measured separately in the electronic domain and the phase error signal is feedback to the LiNbO 3 phase modulator for that leg to minimize the phase error for that leg relative to the reference leg. The advantages of this technique are 1) the elimination of the reference beam and beam combination optics and 2) the electronic separation of the phase error signals without any degradation of the phase locking accuracy. We will present the first theoretical model for self-referenced LOCSET and describe experimental results for a 3 x 3 array.
Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications
NASA Technical Reports Server (NTRS)
Larsen, Kameron (Inventor); Burt, Eric A. (Inventor); Tjoelker, Robert L. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor)
2017-01-01
An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.
Appearance of Keplerian discs orbiting Kerr superspinars
NASA Astrophysics Data System (ADS)
Stuchlík, Zdeněk; Schee, Jan
2010-11-01
We study optical phenomena related to the appearance of Keplerian accretion discs orbiting Kerr superspinars predicted by string theory. The superspinar exterior is described by standard Kerr naked singularity geometry breaking the black hole limit on the internal angular momentum (spin). We construct local photon escape cones for a variety of orbiting sources that enable us to determine the superspinars silhouette in the case of distant observers. We show that the superspinar silhouette depends strongly on the assumed edge where the external Kerr spacetime is joined to the internal spacetime governed by string theory and significantly differs from the black hole silhouette. The appearance of the accretion disc is strongly dependent on the value of the superspinar spin in both their shape and frequency shift profile. Apparent extension of the disc grows significantly with the growing spin, while the frequency shift grows with the descending spin. This behaviour differs substantially from the appearance of discs orbiting black holes enabling thus, at least in principle, to distinguish clearly the Kerr superspinars and black holes. In vicinity of a Kerr superspinar the non-escaped photons have to be separated to those captured by the superspinar and those being trapped in its strong gravitational field leading to self-illumination of the disc that could even influence its structure and cause self-reflection effect of radiation of the disc. The amount of trapped photons grows with descending superspinar spin. We thus can expect significant self-illumination effects in the field of Kerr superspinars with near-extreme spin a ~ 1.
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G; Walser, Sandra M; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E W
2017-01-01
Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Data from 278 participants (aged 18-23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort.
Quasi-Phasematched Nonlinear Optics: Materials and Devices
2012-02-29
effects all contribute, and that the group velocity dispersion in the vicinity of the pump wavelength and are important factors influencing the breadth...for the physics underlying χ(2) SC generation, so the work was purely empirical, but still resulted in octave-class SC and envelop locking with...specific goals, e.g soliton self-frequency shift, SC generation, etc. emerged, and could then be optimized with the numerical simulation tool
ERIC Educational Resources Information Center
Swink, Shannon; Stuart, Andrew
2012-01-01
The effect of gender on the N1-P2 auditory complex was examined while listening and speaking with altered auditory feedback. Fifteen normal hearing adult males and 15 females participated. N1-P2 components were evoked while listening to self-produced nonaltered and frequency shifted /a/ tokens and during production of /a/ tokens during nonaltered…
Asymmetric wave transmission in a diatomic acoustic/elastic metamaterial
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Bing; Tan, K. T., E-mail: ktan@uakron.edu
2016-08-21
Asymmetric acoustic/elastic wave transmission has recently been realized using nonlinearity, wave diffraction, or bias effects, but always at the cost of frequency distortion, direction shift, large volumes, or external energy. Based on the self-coupling of dual resonators, we propose a linear diatomic metamaterial, consisting of several small-sized unit cells, to realize large asymmetric wave transmission in low frequency domain (below 1 kHz). The asymmetric transmission mechanism is theoretically investigated, and numerically verified by both mass-spring and continuum models. This passive system does not require any frequency conversion or external energy, and the asymmetric transmission band can be theoretically predicted andmore » mathematically controlled, which extends the design concept of unidirectional transmission devices.« less
Wei, Wenjia; Heinze, Stefanie; Gerstner, Doris G.; Walser, Sandra M.; Twardella, Dorothee; Reiter, Christina; Weilnhammer, Veronika; Perez-Alvarez, Carmelo; Steffens, Thomas; Herr, Caroline E.W.
2017-01-01
Background: Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. Materials and Methods: A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. Results: Data from 278 participants (aged 18–23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. Conclusion: This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort. PMID:29319010
NASA Astrophysics Data System (ADS)
Li, Wenjiang; He, Jinglong; He, Sailing
2005-02-01
The colorful artificial 3D silica colloidal crystals (opal) were prepared through self-assembly of silica spheres in the visible frequency range. We directly synthesized nano silver particles in the void of the silica artificial opal film using the photolysis of silver nitrate under UV light, nano silver particles were self-deposited around the surface of silica sphere. The shifts of the stop band of the artificial crystals after exposing different time under UV light were studied. Synthetic silica opal with three-dimensional (3D) structure is potentially useful for the development of diffractive optical devices, micro mechanical systems, and sensory elements because photonic band gaps obtained from self-assembled closely packed periodic structures.
Effects of hydrogen atom spin exchange collisions on atomic hydrogen maser oscillation frequency
NASA Technical Reports Server (NTRS)
Crampton, S. B.
1979-01-01
Frequency shifts due to collisions between hydrogen atoms in an atomic hydrogen maser frequency standard are studied. Investigations of frequency shifts proportional to the spin exchange frequency shift cross section and those proportional to the duration of exchange collisions are discussed. The feasibility of operating a hydrogen frequency standard at liquid helium temperatures is examined.
NASA Astrophysics Data System (ADS)
Matsushita, Satoki; Asaki, Yoshiharu; Fomalont, Edward B.; Morita, Koh-Ichiro; Barkats, Denis; Hills, Richard E.; Kawabe, Ryohei; Maud, Luke T.; Nikolic, Bojan; Tilanus, Remo P. J.; Vlahakis, Catherine; Whyborn, Nicholas D.
2017-03-01
We present millimeter- and submillimeter-wave phase characteristics measured between 2012 and 2014 of Atacama Large Millimeter/submillimeter Array long baseline campaigns. This paper presents the first detailed investigation of the characteristics of phase fluctuation and phase correction methods obtained with baseline lengths up to ˜15 km. The basic phase fluctuation characteristics can be expressed with the spatial structure function (SSF). Most of the SSFs show that the phase fluctuation increases as a function of baseline length, with a power-law slope of ˜0.6. In many cases, we find that the slope becomes shallower (average of ˜0.2-0.3) at baseline lengths longer than ˜1 km, namely showing a turn-over in SSF. These power law slopes do not change with the amount of precipitable water vapor (PWV), but the fitted constants have a weak correlation with PWV, so that the phase fluctuation at a baseline length of 10 km also increases as a function of PWV. The phase correction method using water vapor radiometers (WVRs) works well, especially for the cases where PWV > 1 {mm}, which reduces the degree of phase fluctuations by a factor of two in many cases. However, phase fluctuations still remain after the WVR phase correction, suggesting the existence of other turbulent constituent that cause the phase fluctuation. This is supported by occasional SSFs that do not exhibit any turn-over; these are only seen when the PWV is low (i.e., when the WVR phase correction works less effectively) or after WVR phase correction. This means that the phase fluctuation caused by this turbulent constituent is inherently smaller than that caused by water vapor. Since in these rare cases there is no turn-over in the SSF up to the maximum baseline length of ˜15 km, this turbulent constituent must have scale height of 10 km or more, and thus cannot be water vapor, whose scale height is around 1 km. Based on the characteristics, this large scale height turbulent constituent is likely to be water ice or a dry component. Excess path length fluctuation after the WVR phase correction at a baseline length of 10 km is large (≳ 200 μ {{m}}), which is significant for high frequency (> 450 {GHz} or < 700 μ {{m}}) observations. These results suggest the need for an additional phase correction method to reduce the degree of phase fluctuation, such as fast switching, in addition to the WVR phase correction. We simulated the fast switching phase correction method using observations of single quasars, and the result suggests that it works well, with shorter cycle times linearly improving the coherence.
NASA Astrophysics Data System (ADS)
Won, Yong-Yuk; Jung, Sang-Min; Han, Sang-Kook
2014-08-01
A new technique, which reduces optical beat interference (OBI) noise in orthogonal frequency division multiple access-passive optical network (OFDMA-PON) links, is proposed. A self-homodyne balanced detection, which uses a single laser for the optical line terminal (OLT) as well as for the optical network unit (ONU), reduces OBI noise and also improves the signal to noise ratio (SNR) of the discrete multi-tone (DMT) signal. The proposed scheme is verified by transmitting quadrature phase shift keying (QPSK)-modulated DMT signal over a 20-km single mode fiber. The optical signal to noise ratio (OSNR), that is required for BER of 10-5, is reduced by 2 dB in the balanced detection compared with a single channel due to the cancellation of OBI noise in conjunction with the local laser.
Single-mode dispersive waves and soliton microcomb dynamics
Yi, Xu; Yang, Qi-Fan; Zhang, Xueyue; Yang, Ki Youl; Li, Xinbai; Vahala, Kerry
2017-01-01
Dissipative Kerr solitons are self-sustaining optical wavepackets in resonators. They use the Kerr nonlinearity to both compensate dispersion and offset optical loss. Besides providing insights into nonlinear resonator physics, they can be applied in frequency metrology, precision clocks, and spectroscopy. Like other optical solitons, the dissipative Kerr soliton can radiate power as a dispersive wave through a process that is the optical analogue of Cherenkov radiation. Dispersive waves typically consist of an ensemble of optical modes. Here, a limiting case is studied in which the dispersive wave is concentrated into a single cavity mode. In this limit, its interaction with the soliton induces hysteresis behaviour in the soliton's spectral and temporal properties. Also, an operating point of enhanced repetition-rate stability occurs through balance of dispersive-wave recoil and Raman-induced soliton-self-frequency shift. The single-mode dispersive wave can therefore provide quiet states of soliton comb operation useful in many applications. PMID:28332495
Enhancement of high-order harmonics in a plasma waveguide formed in clustered Ar gas.
Geng, Xiaotao; Zhong, Shiyang; Chen, Guanglong; Ling, Weijun; He, Xinkui; Wei, Zhiyi; Kim, Dong Eon
2018-02-05
Generation of high-order harmonics (HHs) is intensified by using a plasma waveguide created by a laser in a clustered gas jet. The formation of a plasma waveguide and the guiding of a laser beam are also demonstrated. Compared to the case without a waveguide, harmonics were strengthened up to nine times, and blue-shifted. Numerical simulation by solving the time-dependent Schrödinger equation in strong field approximation agreed well with experimental results. This result reveals that the strengthening is the result of improved phase matching and that the blue shift is a result of change in fundamental laser frequency due to self-phase modulation (SPM).
A source mechanism producing HF-induced plasma lines (HFPLS) with up-shifted frequencies
NASA Technical Reports Server (NTRS)
Kuo, S. P.; Lee, M. C.
1992-01-01
Attention is given to a nonlinear scattering process analyzed as a source mechanism producing the frequency up-shifted HFPLs observed in the Arecibo ionospheric heating experiments. A physical picture is offered to explain how Langmuir waves with frequencies greater than the HF heater wave frequency can be produced in the heating experiments and be detected by incoherent radars as frequency up-shifted HFPLs. Since the considered scattering process occurs in a region near the reflection height, it explains why the frequency up-shifted HFPLs should originate from the altitude near the reflection height as observed. The theory also shows that the amount of frequency up-shift is inversely proportional to the frequency of the HF heater and increases linearly with the electron temperature. The quantitative analysis of the theory shows a good agreement with the experimental results.
Network synchronization in hippocampal neurons.
Penn, Yaron; Segal, Menahem; Moses, Elisha
2016-03-22
Oscillatory activity is widespread in dynamic neuronal networks. The main paradigm for the origin of periodicity consists of specialized pacemaking elements that synchronize and drive the rest of the network; however, other models exist. Here, we studied the spontaneous emergence of synchronized periodic bursting in a network of cultured dissociated neurons from rat hippocampus and cortex. Surprisingly, about 60% of all active neurons were self-sustained oscillators when disconnected, each with its own natural frequency. The individual neuron's tendency to oscillate and the corresponding oscillation frequency are controlled by its excitability. The single neuron intrinsic oscillations were blocked by riluzole, and are thus dependent on persistent sodium leak currents. Upon a gradual retrieval of connectivity, the synchrony evolves: Loose synchrony appears already at weak connectivity, with the oscillators converging to one common oscillation frequency, yet shifted in phase across the population. Further strengthening of the connectivity causes a reduction in the mean phase shifts until zero-lag is achieved, manifested by synchronous periodic network bursts. Interestingly, the frequency of network bursting matches the average of the intrinsic frequencies. Overall, the network behaves like other universal systems, where order emerges spontaneously by entrainment of independent rhythmic units. Although simplified with respect to circuitry in the brain, our results attribute a basic functional role for intrinsic single neuron excitability mechanisms in driving the network's activity and dynamics, contributing to our understanding of developing neural circuits.
Diversified pulse generation from frequency shifted feedback Tm-doped fibre lasers.
Chen, He; Chen, Sheng-Ping; Jiang, Zong-Fu; Hou, Jing
2016-05-19
Pulsed fibre lasers operating in the eye-safe 2 μm spectral region have numerous potential applications in areas such as remote sensing, medicine, mid-infrared frequency conversion, and free-space communication. Here, for the first time, we demonstrate versatile 2 μm ps-ns pulses generation from Tm-based fibre lasers based on frequency shifted feedback and provide a comprehensive report of their special behaviors. The lasers are featured with elegant construction and the unparalleled capacity of generating versatile pulses. The self-starting mode-locking is initiated by an intra-cavity acousto-optical frequency shifter. Diversified mode-locked pulse dynamics were observed by altering the pump power, intra-cavity polarization state and cavity structure, including as short as 8 ps single pulse sequence, pulse bundle state and up to 12 nJ, 3 ns nanosecond rectangular pulse. A reflective nonlinear optical loop mirror was introduced to successfully shorten the pulses from 24 ps to 8 ps. Beside the mode-locking operation, flexible Q-switching and Q-switched mode-locking operation can also be readily achieved in the same cavity. Up to 78 μJ high energy nanosecond pulse can be generated in this regime. Several intriguing pulse dynamics are characterized and discussed.
Arteaga-Sierra, F R; Milián, C; Torres-Gómez, I; Torres-Cisneros, M; Moltó, G; Ferrando, A
2014-09-22
We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on the soliton fission and soliton self-frequency shift occurring during supercontinuum generation. The optimization process is carried out by a genetic algorithm that provides the optimum input pulse parameters: wavelength, temporal width and peak power. This algorithm is implemented in a Grid platform in order to take advantage of distributed computing. These results are useful for optical coherence tomography applications where bell-shaped pulses located in the second near-infrared window are needed.
Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum
NASA Technical Reports Server (NTRS)
Lee, Seungwon
2012-01-01
This software processes the flyby spectra of the Chirp Transform Spectrometer (CTS) of the Microwave Instrument for Rosetta Orbiter (MIRO). The tool corrects the effect of Doppler shift and local-oscillator (LO) frequency shift during the flyby mode of MIRO operations. The frequency correction for CTS flyby spectra is performed and is integrated with multiple spectra into a high signal-to-noise averaged spectrum at the rest-frame RF frequency. This innovation also generates the 8 molecular line spectra by dividing continuous 4,096-channel CTS spectra. The 8 line spectra can then be readily used for scientific investigations. A spectral line that is at its rest frequency in the frame of the Earth or an asteroid will be observed with a time-varying Doppler shift as seen by MIRO. The frequency shift is toward the higher RF frequencies on approach, and toward lower RF frequencies on departure. The magnitude of the shift depends on the flyby velocity. The result of time-varying Doppler shift is that of an observed spectral line will be seen to move from channel to channel in the CTS spectrometer. The direction (higher or lower frequency) in the spectrometer depends on the spectral line frequency under consideration. In order to analyze the flyby spectra, two steps are required. First, individual spectra must be corrected for the Doppler shift so that individual spectra can be superimposed at the same rest frequency for integration purposes. Second, a correction needs to be applied to the CTS spectra to account for the LO frequency shifts that are applied to asteroid mode.
NASA Astrophysics Data System (ADS)
Smith, E. F.; Macdonald, F. A.; Schrag, D. P.; Laakso, T.
2014-12-01
The GSSP Precambrian-Cambrian boundary in Newfoundland is defined by the first appearance datum (FAD) of Treptichnus pedum, which is considered to be roughly coincident with the FAD of small shelly fossils (SSFs) and a large negative carbon isotope excursion. An association between the FAD of T. pedum and a negative carbon isotope excursion has previously been documented in Northwest Canada (Narbonne et al., 1994) and Death Valley (Corsetti and Hagadorn, 2000), and since then has been used as an chronostratigraphic marker of the boundary, particularly in siliciclastic poor sections that do not preserve T. pedum. Here we present new high-resolution carbon isotope (δ13C ) chemostratigraphy from multiple sections in western Mongolia and the western United States that span the Ediacaran-Cambrian transition. High-resolution sampling (0.2-1 m) reveals that instead of one large negative excursion, there are multiple, high-frequency negative excursions with an overall negative trend during the latest Ediacaran. These data help to more precisely calibrate changes in the carbon cycle across the boundary as well as to highlight the potential problem of identifying the boundary with just a few negative δ13C values. We then use a simple carbon isotope box model to explore relationships between phosphorous delivery to the ocean, oxygenation, alkalinity, and turnovers in carbonate secreting organisms. Corsetti, F.A., and Hagadorn, J.W., 2000, Precambrian-Cambrian transition: Death Valley, United States: Geology, v. 28, no. 4, p. 299-302. Narbonne, G.M., Kaufman, A.J., and Knoll, A.H., 1994, Integrated chemostratigraphy and biostratigraphy of the Windermere Supergroup, northwestern Canada: Implications for Neoproterozoic correlations and the early evolution of animals: Geological Society of America Bulletin, v. 106, no. 10, p. 1281-1292.
Binaural beats and frequency-coding.
Fritze, W; Köhler, W
1986-01-01
Binaural beats were studied before and during a situation of temporary threshold shift, and no frequency shift could be found. In contrast, subjective binaural frequency comparison revealed a distinct shift. These findings demonstrate the two known modes of perception.
NASA Astrophysics Data System (ADS)
Liu, Zijian; Corley, Steven; Shenderova, Olga; Brenner, Donald; Krim, Jacqueline
2013-03-01
Nano-diamond (ND) particles are known to be beneficial for wear and friction reduction when used as additives in liquids, but the fundamental origins of the improvement in tribological properties has not been established. In order to explore this issue, we have investigated the nanotribological properties of ND coated with self-assembled monolayers (SAM) as additives to solutions, employing gold/chrome coated quartz crystal microbalances (QCM). Measurements were performed with the QCM initially immersed in deionized water. ND particles with positively and negatively charged SAM end groups were then added to the water, while the frequency and amplitude of the QCM were monitored. Negative shifts in both the QCM frequency and amplitude were observed when ND with positively charged SAM end groups were added, while positive shifts in both the QCM frequency and amplitude were observed when ND with negatively charged ND end groups were added. The results are consistent with a lubricating effect for the negatively charged ND, but were only observed for sufficiently small negative ND particle size. Experiments on QCM surfaces with differing textures and roughness are in progress, to determine the separate contributing effects of surface roughness charge-water interactions. Funding provided by NSF DMR.
Formation of stimulated electromagnetic emission of the ionosphere: laboratory modeling
NASA Astrophysics Data System (ADS)
Starodubtsev, Mikhail; Kostrov, Alexander; Nazarov, Vladimir
Laboratory modeling of some physical processes involved in generation of the stimulated elec-tromagnetic emission (SEE) is presented. SEE is a noise component observed in the spectrum of the pump electromagnetic wave reflected from the heated ionosphere during the ionospheric heating experiments. In our laboratory experiments, main attention has been paid to the experimental investigation of generation of the most pronounced SEE components connected to the small-scale filamentation of the heated area of the ionosphere. It has been shown that the main physical mechanism of thermal magnetoplasma nonlinearity in this frequency range is due to thermal self-channeling of the Langmuir waves. This mechanism has the minimal threshold and should appear when both laboratory and ionospheric plasmas are heated by high-power radiowaves. Thermal self-channeling of Langmuir waves is connected with the fact that Langmuir waves are trapped in the area of depleted plasma density. As a result, wave amplitude significantly increases in these depleted ragion, which lead to the local plasma heating and, consequently, to the deepening of the plasma density depletion due to plasma thermo-diffusion. As the result, narrow, magnetic-field-aligned plasma density irregularities are formed in a magnetoplasma. Self-channelled Langmuir waves exhibit well-pronoused spectral satellites shifted by 1-2 MHz from the fundamental frequency (about 700 MHz in our experimental conditions). It has been found that there exist two main mechanisms of satellite formation. First mechanism (dynamic) has been observed during the formation of the small-scale irregularity, when its longitudinal size increases fastly. During this process, spectrum of the trapped wave characterizes by one low-frequency satellite. Physical mechanism, which lead to the formation of this satellite is connected to Doppler shift of the frequency of Langmuir waves trapped in the non-stationar plasma irregularity. Second mechanism (stationary) has been observed in the case of the devel-oped irregularity, i.e. when its shape is close to the cylindrical one. In this regime, spectrum of the trapped wave is characterized by two symmetric (Stokes and anti-Stokes) spectral satellites. It has been proposed that generation of these satellites is connected with scattering of trapped Langmuir waves on the drift oscillations of the irregularity.
Do Hearing Protectors Protect Hearing?
Groenewold, Matthew R.; Masterson, Elizabeth A.; Themann, Christa L.; Davis, Rickie R.
2015-01-01
Background We examined the association between self-reported hearing protection use at work and incidence of hearing shifts over a 5-year period. Methods Audiometric data from 19,911 workers were analyzed. Two hearing shift measures—OSHA standard threshold shift (OSTS) and high-frequency threshold shift (HFTS)—were used to identify incident shifts in hearing between workers’ 2005 and 2009 audiograms. Adjusted odds ratios were generated using multivariable logistic regression with multi-level modeling. Results The odds ratio for hearing shift for workers who reported never versus always wearing hearing protection was nonsignificant for OSTS (OR 1.23, 95% CI 0.92–1.64) and marginally significant for HFTS (OR 1.26, 95% CI 1.00–1.59). A significant linear trend towards increased risk of HFTS with decreased use of hearing protection was observed (P = 0.02). Conclusion The study raises concern about the effectiveness of hearing protection as a substitute for noise control to prevent noise-induced hearing loss in the workplace. Am. J. Ind. Med. 57:1001–1010, 2014. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. PMID:24700499
Built-in self-test (BIST) techniques for millimeter wave CMOS transceivers
NASA Astrophysics Data System (ADS)
Mahzabeen, Tabassum
The seamless integration of complementary metal oxide semiconductor (CMOS) transceivers with a digital CMOS process enhances on-chip testability, thus reducing production and testing costs. Built in self testability also improves yield by offering on-chip compensation. This work focuses on built in self test techniques for CMOS based millimeter wave (mm-wave) transceivers. Built-in-self-test (BIST) using the loopback method is one cost-effective method for testing these transceivers. Since the loopback switch is always present during the normal operation of the transceiver, the requirement of the switch is different than for a conventional switch. The switch needs to have high isolation and high impedance during its OFF period. Two 80 GHz single pole single throw (SPST) switches have been designed, fabricated in standard CMOS process, and measured to connect the loopback path for BIST applications. The loopback switches in this work provide the required criteria for loopback BIST. A stand alone 80 GHz low noise amplifier (LNA) and the same LNA integrated with one of the loopback switches have been fabricated, and measured to observe the difference in performance when the loopback switch is present. Besides the loopback switch, substrate leakage also forms a path between the transmitter and receiver. Substrate leakage has been characterized as a function of distance between the transmitter and receiver for consideration in using the BIST method. A BIST algorithm has been developed to estimate the process variation in device sizes by probing a low frequency ring oscillator to estimate the device variation and map this variation to the 80 GHz LNA. Probing a low frequency circuit is cheaper compared to the probing of a millimeter wave circuit and reduces the testing costs. The performance of the LNA degrades due to variation in device size. Once the shift in the device size is being estimated (from the ring oscillator's shifted frequency), the LNA's performance can be recovered using several methods; for example, using tunable transmission line lengths in the amplifier or using a variable supply voltage. This concept of estimating process variation has been demonstrated in Agilent Design System (ADS).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feister, S., E-mail: feister.7@osu.edu; Orban, C.; Innovative Scientific Solutions, Inc., Dayton, Ohio 45459
Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiersmore » synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.« less
Edge technique for measurement of laser frequency shifts including the Doppler shift
NASA Technical Reports Server (NTRS)
Korb, Larry (Inventor)
1991-01-01
A method is disclosed for determining the frequency shift in a laser system by transmitting an outgoing laser beam. An incoming laser beam having a frequency shift is received. A first signal is acquired by transmitting a portion of the incoming laser beam to an energy monitor detector. A second signal is acquired by transmitting a portion of the incoming laser beam through an edge filter to an edge detector, which derives a first normalized signal which is proportional to the transmission of the edge filter at the frequency of the incoming laser beam. A second normalized signal is acquired which is proportional to the transmission of the edge filter at the frequency of the outgoing laser beam. The frequency shift is determined by processing the first and second normalized signals.
NASA Astrophysics Data System (ADS)
McConnell, Gail; Riis, Erling
2004-10-01
We report on a novel and compact reliable laser source capable of short-wavelength two-photon laser scanning fluorescence microscopy based on soliton self-frequency shift effects in photonic crystal fibre. We demonstrate the function of the system by performing two-photon microscopy of smooth muscle cells and cardiac myocytes from the rat pulmonary vein and Chinese hamster ovary cells loaded with the fluorescent calcium indicator fura-2/AM.
2010-01-01
science and engineering. For example, by measuring the frequency shift of sensor oscillations, one can measure gas adsorption on the sensor surface...free-molecular regime with varied gas pressure. The measurement path of the experimental setup is schematically shown in Fig. 3.1. The sensor is...excited by the electric field between the sensor and fixed electrode by means of a specially designed system of self-induced oscillations. The
Frequency shift of the Bragg and Non-Bragg backscattering from periodic water wave
NASA Astrophysics Data System (ADS)
Wen, Biyang; Li, Ke
2016-08-01
Doppler effect is used to measure the relative speed of a moving target with respect to the radar, and is also used to interpret the frequency shift of the backscattering from the ocean wave according to the water-wave phase velocity. The widely known relationship between the Doppler shift and the water-wave phase velocity was deduced from the scattering measurements data collected from actual sea surface, and has not been verified under man-made conditions. Here we show that this ob- served frequency shift of the scattering data from the Bragg and Non-Bragg water wave is not the Doppler shift corresponding to the water-wave phase velocity as commonly believed, but is the water-wave frequency and its integral multiple frequency. The power spectrum of the backscatter from the periodic water wave consists of serials discrete peaks, which is equally spaced by water wave frequency. Only when the water-wave length is the integer multiples of the Bragg wave, and the radar range resolution is infinite, does the frequency shift of the backscattering mathematically equal the Doppler shift according to the water-wave phase velocity.
Effects of frequency shifts and visual gender information on vowel category judgments
NASA Astrophysics Data System (ADS)
Glidden, Catherine; Assmann, Peter F.
2003-10-01
Visual morphing techniques were used together with a high-quality vocoder to study the audiovisual contribution of talker gender to the identification of frequency-shifted vowels. A nine-step continuum ranging from ``bit'' to ``bet'' was constructed from natural recorded syllables spoken by an adult female talker. Upward and downward frequency shifts in spectral envelope (scale factors of 0.85 and 1.0) were applied in combination with shifts in fundamental frequency, F0 (scale factors of 0.5 and 1.0). Downward frequency shifts generally resulted in malelike voices whereas upward shifts were perceived as femalelike. Two separate nine-step visual continua from ``bit'' to ``bet'' were also constructed, one from a male face and the other a female face, each producing the end-point words. Each step along the two visual continua was paired with the corresponding step on the acoustic continuum, creating natural audiovisual utterances. Category boundary shifts were found for both acoustic cues (F0 and formant frequency shifts) and visual cues (visual gender). The visual gender effect was larger when acoustic and visual information were matched appropriately. These results suggest that visual information provided by the speech signal plays an important supplemental role in talker normalization.
Frequency shifts of an electric-dipole resonance near a conducting surface
NASA Technical Reports Server (NTRS)
Holland, W. R.; Hall, D. G.
1984-01-01
The resonance frequency of an electric dipole placed near a conducting surface is shifted by the dipole-surface interaction. The observation and measurement of these shifts at optical frequencies is reported for an experimental system that consists of a metal-island film spaced a distance d from a continuous Ag film. The dependence of the shift in the frequency of the island resonance on d shows good agreement with that predicted by a classical theory of the dipole-surface interaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toriyama, Koichi; Oguchi, Akihide; Morinaga, Atsuo
2011-12-15
We investigate the phenomenon that a Berry phase evolving linearly in time induces a frequency shift of the resonance transition between two eigenstates, regardless of whether or not they are superposed. Using the magnetic-field-insensitive two-photon microwave--radio-frequency transition, which is free of any other dynamical frequency shift, we demonstrate that the frequency shift caused by a uniform rotation of the magnetic field corresponds to the derivative of the Berry phase with respect to time and depends on the direction of rotation of the magnetic field.
NASA Astrophysics Data System (ADS)
Saikia, P.; Bhuyan, H.; Escalona, M.; Favre, M.; Bora, B.; Kakati, M.; Wyndham, E.; Rawat, R. S.; Schulze, J.
2018-05-01
We investigate the electrical asymmetry effect (EAE) and the current dynamics in a geometrically asymmetric capacitively coupled radio frequency plasma driven by multiple consecutive harmonics based on a nonlinear global model. The discharge symmetry is controlled via the EAE, i.e., by varying the total number of harmonics and tuning the phase shifts ( θ k ) between them. Here, we systematically study the EAE in a low pressure (4 Pa) argon discharge with different geometrical asymmetries driven by a multifrequency rf source consisting of 13.56 MHz and its harmonics. We find that the geometrical asymmetry strongly affects the absolute value of the DC self-bias voltage, but its functional dependence on θ k is similar at different values of the geometrical asymmetry. Also, the values of the DC self-bias are enhanced by adding more consecutive harmonics. The voltage drop across the sheath at the powered and grounded electrode is found to increase/decrease, respectively, with the increase in the number of harmonics of the fundamental frequency. For the purpose of validating the model, its outputs are compared with the results obtained in a geometrically and electrically asymmetric 2f capacitively coupled plasmas experiment conducted by Schuengel et al. [J. Appl. Phys. 112, 053302 (2012)]. Finally, we study the self-excitation of nonlinear plasma series resonance oscillations and its dependence on the geometrical asymmetry as well as the phase angles between the driving frequencies.
Tang, W W; Shu, C
2005-02-21
We demonstrate a regeneratively mode-locked optical pulse source at about 10 GHz using an optoelectronic oscillator constructed with an electro-absorption modulator integrated distributed feedback laser diode. The 10 GHz RF component is derived from the interaction between the pump wave and the backscattered, frequency-downshifted Stokes wave resulted from stimulated Brillouin scattering in an optical fiber. The component serves as a modulation source for the 1556 nm laser diode without the need for any electrical or optical RF filter to perform the frequency extraction. Dispersion-compensated fiber, dispersion-shifted fiber, and standard single-mode fiber have been used respectively to generate optical pulses at variable repetition rates.
Numerical investigation of frequency spectrum in the Hasegawa-Wakatani model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Juhyung; Terry, P. W.
2013-10-15
The wavenumber-frequency spectrum of the two-dimensional Hasegawa-Wakatani model is investigated in the hydrodynamic, intermediate, and adiabatic regimes. A nonlinear frequency and a line width related to energy transfer properties provide a measure of the average frequency and spectral broadening, respectively. In the adiabatic regime, narrow spectra, typical of wave turbulence, are observed with a nonlinear frequency shift in the electron drift direction. In the hydrodynamic regime, broad spectra with almost zero nonlinear frequencies are observed. Nonlinear frequency shifts are shown to be related to nonlinear energy transfer by vorticity advection through the high frequency region of the spectrum. In themore » intermediate regime, the nonlinear frequency shift for density fluctuations is observed to be weaker than that of electrostatic potential fluctuations. The weaker frequency shift of the density fluctuations is due to nonlinear density advection, which favors energy transfer in the low frequency range. Both the nonlinear frequency and the spectral width increase with poloidal wavenumber k{sub y}. In addition, in the adiabatic regime where the nonlinear interactions manifest themselves in the nonlinear frequency shift, the cross-phase between the density and potential fluctuations is observed to match a linear relation, but only if the linear response of the linearly stable eigenmode branch is included. Implications of these numerical observations are discussed.« less
Cascaded a-cut Nd:YVO4 self-Raman with second-Stokes laser at 1313 nm
NASA Astrophysics Data System (ADS)
Xie, Zhi; Duan, Yanmin; Guo, Junhong; Huang, Xiaohong; Yan, Lifen; Zhu, Haiyong
2017-11-01
A diode-end-pumped, acousto-optic Q-switched second-Stokes self-Raman laser at 1313 nm was demonstrated in a common a-cut Nd:YVO4 crystal, with the primary Raman shift of 890 cm-1. At the incident pump power of 17.1 W, the maximum average output power up to 2.51 W and pulse width of 5 ns for second-Stokes were obtained with the pulse repetition frequency of 50 kHz. The slope efficiency and conversion efficiency with respect to the incident pump power are about 23.7% and 14.7%. The efficient output should be attributed to suitable transmittance of the output coupler used.
Effects of a chirped bias voltage on ion energy distributions in inductively coupled plasma reactors
NASA Astrophysics Data System (ADS)
Lanham, Steven J.; Kushner, Mark J.
2017-08-01
The metrics for controlling reactive fluxes to wafers for microelectronics processing are becoming more stringent as feature sizes continue to shrink. Recent strategies for controlling ion energy distributions to the wafer involve using several different frequencies and/or pulsed powers. Although effective, these strategies are often costly or present challenges in impedance matching. With the advent of matching schemes for wide band amplifiers, other strategies to customize ion energy distributions become available. In this paper, we discuss results from a computational investigation of biasing substrates using chirped frequencies in high density, electronegative inductively coupled plasmas. Depending on the frequency range and chirp duration, the resulting ion energy distributions exhibit components sampled from the entire frequency range. However, the chirping process also produces transient shifts in the self-generated dc bias due to the reapportionment of displacement and conduction with frequency to balance the current in the system. The dynamics of the dc bias can also be leveraged towards customizing ion energy distributions.
Frequency Shift During Mass Properties Testing Using Compound Pendulum Method
NASA Technical Reports Server (NTRS)
Wolfe, David; Regan, Chris
2012-01-01
During mass properties testing on the X-48B Blended Wing Body aircraft (The Boeing Company, Chicago, Illinois) at the National Aeronautics and Space Administration Dryden Flight Research Center, Edwards, California, large inertia measurement errors were observed in results from compound pendulum swings when compared to analytical models. By comparing periods of oscillations as measured from an average over the test period versus the period of each oscillation, it was noticed that the frequency of oscillation was shifting significantly throughout the test. This phenomenon was only noticed during compound pendulum swings, and not during bifilar pendulum swings. The frequency shift was only visible upon extensive data analysis of the frequency for each oscillation, and did not appear in averaged frequency data over the test period. Multiple test articles, test techniques, and hardware setups were used in attempts to eliminate or identify the cause of the frequency shift. Plotting the frequency of oscillation revealed a region of minimal shift that corresponded to a larger amplitude range. This region of minimal shift provided the most accurate results compared to a known test article; however, the amplitudes that produce accurate inertia measurements are amplitudes larger than those generally accepted in mass properties testing. This paper examines two case studies of the frequency shift, using mass properties testing performed on a dummy test article, and on the X-48B Blended Wing Body aircraft.
NASA Astrophysics Data System (ADS)
Santos, Ângela R. G.; Cunha, Margarida S.; Avelino, Pedro P.; Chaplin, William J.; Campante, Tiago L.
2017-10-01
The activity-related variations in the solar acoustic frequencies have been known for 30 years. However, the importance of the different contributions is still not well established. With this in mind, we developed an empirical model to estimate the spot-induced frequency shifts, which takes into account the sunspot properties, such as area and latitude. The comparison between the model frequency shifts obtained from the daily sunspot records and those observed suggests that the contribution from a stochastic component to the total frequency shifts is about 30%. The remaining 70% is related to a global, long-term variation. We also propose a new observable to investigate the short-and mid-term variations of the frequency shifts, which is insensitive to the long-term variations contained in the data. On the shortest time scales the variations in the frequency shifts are strongly correlated with the variations in the total area covered by sunspots. However, a significant loss of correlation is still found, which cannot be fully explained by ignoring the invisible side of the Sun when accounting for the total sunspot area. We also verify that the times when the frequency shifts and the sunspot areas do not vary in a similar way tend to coincide with the times of the maximum amplitude of the quasi-biennial variations found in the seismic data.
Frequency shifts in gravitational resonance spectroscopy
Baeßler, S.; Nesvizhevsky, V. V.; Pignol, G.; ...
2015-02-25
Quantum states of ultracold neutrons in a gravitational field are characterized through gravitational resonance spectroscopy. This paper discusses systematic effects that appear in the spectroscopic measurements. The discussed frequency shifts-which we call the Stern-Gerlach shift, interference shift, and spectator-state shift-appear in conceivable measurement schemes and have general importance. Lastly, these shifts have to be taken into account in precision experiments.
NASA Astrophysics Data System (ADS)
Wang, Weizhou; Zhang, Yu; Ji, Baoming; Tian, Anmin
2011-06-01
The C-Hal (Hal = Cl, Br, or I) bond-length change and the corresponding vibrational frequency shift of the C-Hal stretch upon the C-Hal ⋯Y (Y is the electron donor) halogen bond formation have been determined by using density functional theory computations. Plots of the C-Hal bond-length change versus the corresponding vibrational frequency shift of the C-Hal stretch all give straight lines. The coefficients of determination range from 0.94366 to 0.99219, showing that the correlation between the C-Hal bond-length change and the corresponding frequency shift is very good in the halogen-bonded complexes. The possible effects of vibrational coupling, computational method, and anharmonicity on the bond-length change-frequency shift correlation are discussed in detail.
Self-consistent Langmuir waves in resonantly driven thermal plasmas
NASA Astrophysics Data System (ADS)
Lindberg, R. R.; Charman, A. E.; Wurtele, J. S.
2007-12-01
The longitudinal dynamics of a resonantly driven Langmuir wave are analyzed in the limit that the growth of the electrostatic wave is slow compared to the bounce frequency. Using simple physical arguments, the nonlinear distribution function is shown to be nearly invariant in the canonical particle action, provided both a spatially uniform term and higher-order spatial harmonics are included along with the fundamental in the longitudinal electric field. Requirements of self-consistency with the electrostatic potential yield the basic properties of the nonlinear distribution function, including a frequency shift that agrees closely with driven, electrostatic particle simulations over a range of temperatures. This extends earlier work on nonlinear Langmuir waves by Morales and O'Neil [G. J. Morales and T. M. O'Neil, Phys. Rev. Lett. 28, 417 (1972)] and Dewar [R. L. Dewar, Phys. Plasmas 15, 712 (1972)], and could form the basis of a reduced kinetic treatment of plasma dynamics for accelerator applications or Raman backscatter.
Self-consistent frequencies of the electron-photon system
NASA Astrophysics Data System (ADS)
Hawton, Margaret
1993-09-01
The Heisenberg equations describing the dynamics of coupled Fermion photon operators are solved self-consistently. Photon modes, for which ω~=kc, and particlelike Bohr modes with frequencies ωnI~=(En-EI)/ħ are both approximate solutions to the system of equations that results if the current density is the source in the operator Maxwell equations. Current fluctuations associated with the Bohr modes and required by a fluctuation-dissipation theorem are attributed to the point nature of the particle. The interaction energy is given by the Casimir-force-like expression ΔE=1/2ħtsum(ΔωnI+Δωkc) or by the expectation value of 1/2(qcphi-qp^.A^/mc+q2A2/mc2). It is verified that the equal-time momentum-density and vector-potential operators commute if the contributions of both the Bohr modes and vacuum fluctuations are included. Both electromagnetic and Bohr or radiation-reaction modes are found to contribute equally to spontaneous emission and to the Lamb shift.
Self-Raman Nd:YVO4 laser and electro-optic technology for space-based sodium lidar instrument
NASA Astrophysics Data System (ADS)
Krainak, Michael A.; Yu, Anthony W.; Janches, Diego; Jones, Sarah L.; Blagojevic, Branimir; Chen, Jeffrey
2014-02-01
We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nm. A CW External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nm. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nm. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9W @ 532 nm wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.
Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument
NASA Technical Reports Server (NTRS)
Krainak, Michael A.; Yu, Anthony W.; Janches, Diego; Jones, Sarah L.; Blagojevic, Branimir; Chen, Jeffrey
2014-01-01
We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.
Frequency-noise cancellation in semiconductor lasers by nonlinear heterodyne detection.
Bondurant, R S; Welford, D; Alexander, S B; Chan, V W
1986-12-01
The bit-error-rate (BER) performance of conventional noncoherent, heterodyne frequency-shift-keyed (FSK) optical communications systems can be surpassed by the use of a differential FSK modulation format and nonlinear postdetection processing at the receiver. A BER floor exists for conventional frequency-shift keying because of the frequency noise of the transmitter and local oscillator. The use of differential frequency-shift keying with nonlinear postdetection processing suppresses this BER floor for the semiconductor laser system considered here.
Analysis of self-homodyne detection for 6-mode fiber with low-modal crosstalk
NASA Astrophysics Data System (ADS)
Guo, Meng; Hu, Guijun
2017-12-01
In this paper, we present an appropriate analysis on self-homodyne coherent system with 56 × 5 × 3 Gb / s WDM-PDM-MDM quadrature phase-shift keying (QPSK) signals using 6-mode weakly coupled few mode fiber. The mode division technology can effectively improve the spectral efficiency (SE) of self-homodyne detection. Of all the LP modes, LP01 mode is used to transmit the pilot tone (PT), while the others for signal channels. The influence of inter-mode crosstalk is analyzed. The proposed frequency domain MMA shows a better BER performance for intra-mode crosstalk elimination. The path-length misalignment's influence caused by mode differential group delay (MDGD) is also investigated. The system tolerance for different laser's line-width is compared as well as the influence of PT filter's bandwidth.
ERIC Educational Resources Information Center
Riedel, Sharon; And Others
Self-report, pre/post testing is a frequently employed measure of therapeutic change. To investigate whether expectation of change might be an alternative explanation to the scale shift explanation of response shift bias in a self-report measure, a two-session assertiveness training intervention for college women was evaluated under manipulated…
Light beam frequency comb generator
Priatko, G.J.; Kaskey, J.A.
1992-11-24
A light beam frequency comb generator uses an acousto-optic modulator to generate a plurality of light beams with frequencies which are uniformly separated and possess common noise and drift characteristics. A well collimated monochromatic input light beam is passed through this modulator to produce a set of both frequency shifted and unshifted optical beams. An optical system directs one or more frequency shifted beams along a path which is parallel to the path of the input light beam such that the frequency shifted beams are made incident on the modulator proximate to but separated from the point of incidence of the input light beam. After the beam is thus returned to and passed through the modulator repeatedly, a plurality of mutually parallel beams are generated which are frequency-shifted different numbers of times and possess common noise and drift characteristics. 2 figs.
Light beam frequency comb generator
Priatko, Gordon J.; Kaskey, Jeffrey A.
1992-01-01
A light beam frequency comb generator uses an acousto-optic modulator to generate a plurality of light beams with frequencies which are uniformly separated and possess common noise and drift characteristics. A well collimated monochromatic input light beam is passed through this modulator to produce a set of both frequency shifted and unshifted optical beams. An optical system directs one or more frequency shifted beams along a path which is parallel to the path of the input light beam such that the frequency shifted beams are made incident on the modulator proximate to but separated from the point of incidence of the input light beam. After the beam is thus returned to and passed through the modulator repeatedly, a plurality of mutually parallel beams are generated which are frequency-shifted different numbers of times and possess common noise and drift characteristics.
Pressure broadening and frequency shift of the D 1 and D 2 lines of K in the presence of Ne and Kr
NASA Astrophysics Data System (ADS)
Wang, Xulin; Chen, Yao; Quan, Wei; Chi, Haotian; Fang, Jiancheng
2018-02-01
We present the results of pressure broadening and frequency shift of K D 1 and D 2 lines in presence of 1-4 amg of Neon gas and 1-5 amg of Krypton gas by laser absorption spectroscopy. Both pressure broadening and frequency shift are linearly related to gas density with high accuracy. The asymmetry of the absorption line shape caused by van der Waals potential was first found in the near-line wings of large density Kr in the experiment. We have also investigated the temperature dependence of the pressure broadening and frequency shift in a range of 353-403 K in Neon and 373-417 K in Krypton and compared the results of the pressure broadening and frequency shift with previous values.
[Shiftwork and health--experience from a chemical company].
Oberlinner, C; Lang, S; Nasterlack, M; Yong, M
2013-03-01
Shiftwork is an essential part of our society. At the same time scientific evaluations demonstrate possible negative effects of shiftwork on the health status of the employees. Against this background we performed different studies to evaluate these effects within the specific shift system in a large chemical site in Germany. METHODS AND STUDY GROUP: To evaluate the impact of the different working times on job-related stress perception and work-life-balance we performed a cross-sectional study with 1494 blue collar workers (825 shift- and 669 day workers). Employees working in the rotating shift system reported lower frequencies of perceived time pressure (p = 0.008), and lower stress levels (p = 0.01), compared to the day workers. No significant difference was found with regard to work-life-balance and other aspects of job-related stress perception within both groups. Against the general opinion and study-results in the past we did not find a negative effect of our shift-system on self-reported stress. These results are in accordance with results of other cohort-studies on the specific shift system within the company demonstrating no difference in the health status of our shift workers compared to day workers. © Georg Thieme Verlag KG Stuttgart · New York.
Ball, Jane; Day, Tina; Murrells, Trevor; Dall'Ora, Chiara; Rafferty, Anne Marie; Griffiths, Peter; Maben, Jill
2017-01-01
Twenty-four hour nursing care involves shift work including 12-h shifts. England is unusual in deploying a mix of shift patterns. International evidence on the effects of such shifts is growing. A secondary analysis of data collected in England exploring outcomes with 12-h shifts examined the association between shift length, job satisfaction, scheduling flexibility, care quality, patient safety, and care left undone. Data were collected from a questionnaire survey of nurses in a sample of English hospitals, conducted as part of the RN4CAST study, an EU 7 th Framework funded study. The sample comprised 31 NHS acute hospital Trusts from 401 wards, in 46 acute hospital sites. Descriptive analysis included frequencies, percentages and mean scores by shift length, working beyond contracted hours and day or night shift. Multi-level regression models established statistical associations between shift length and nurse self-reported measures. Seventy-four percent (1898) of nurses worked a day shift and 26% (670) a night shift. Most Trusts had a mixture of shifts lengths. Self-reported quality of care was higher amongst nurses working ≤8 h (15.9%) compared to those working longer hours (20.0 to 21.1%). The odds of poor quality care were 1.64 times higher for nurses working ≥12 h (OR = 1.64, 95% CI 1.18-2.28, p = 0.003). Mean 'care left undone' scores varied by shift length: 3.85 (≤8 h), 3.72 (8.01-10.00 h), 3.80 (10.01-11.99 h) and were highest amongst those working ≥12 h (4.23) ( p < 0.001). The rate of care left undone was 1.13 times higher for nurses working ≥12 h (RR = 1.13, 95% CI 1.06-1.20, p < 0.001). Job dissatisfaction was higher the longer the shift length: 42.9% (≥12 h (OR = 1.51, 95% CI 1.17-1.95, p = .001); 35.1% (≤8 h) 45.0% (8.01-10.00 h), 39.5% (10.01-11.99 h). Our findings add to the growing international body of evidence reporting that ≥12 shifts are associated with poor ratings of quality of care and higher rates of care left undone. Future research should focus on how 12-h shifts can be optimised to minimise potential risks.
A physiological frequency-position map of the chinchilla cochlea.
Müller, Marcus; Hoidis, Silvi; Smolders, Jean W T
2010-09-01
Accumulating evidence indicates that mammalian cochlear frequency-position maps (location of maximum vibration of the basilar membrane as a function of frequency) depend on the physiological condition of the inner ear. Cochlear damage desensitizes the ear, after the damage the original location of maximum vibration is tuned to a lower sound frequency. This suggests that frequency-position maps, derived from such desensitized ears, are shifted to lower frequencies, corresponding to a shift of the basilar membrane vibration pattern towards the base for a given stimulus frequency. To test this hypothesis, we re-mapped the cochlear frequency-position map in the chinchilla. We collected frequency-position data from chinchillas in normal physiological condition ("physiological map") and compared these to data previously established from sound overexposed ears ("anatomical map"). The characteristic frequency (CF) of neurons in the cochlear nucleus was determined. Horse-radish peroxidase (HRP) or biocytin (BCT) were injected iontophoretically to trace auditory nerve fibers towards their innervation site in the organ of Corti. The relationship between distance from the base (d, percent) and frequency (f, kHz) was described best by a simple exponential function: d = 61.2 - 42.2 x log(f). The slope of the function was 2.55 mm/octave. Compared to the "anatomical map", the "physiological map" was shifted by about 0.3 octaves to higher frequencies corresponding to a shift of the basilar membrane vibration pattern of 0.8 mm towards the apex for a given stimulus frequency. Our findings affirm that frequency-position maps in the mammalian cochlea depend on the condition of the inner ear. Damage-induced desensitization in mammalian inner ears results in similar shifts of CF (about 0.5 octaves) but different shifts of the maximum of the vibration pattern towards the base at given frequencies, dependent on the mapping constant of the species, longer basilar membranes showing a larger basal shift. Furthermore, the results substantiate the notion that "crowding" at lower frequencies appears to be a specialization rather than a general feature. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Adaptive optics in multiphoton microscopy: comparison of two, three and four photon fluorescence
Sinefeld, David; Paudel, Hari P.; Ouzounov, Dimitre G.; Bifano, Thomas G.; Xu, Chris
2015-01-01
We demonstrate adaptive optics system based on nonlinear feedback from 3- and 4-photon fluorescence. The system is based on femtosecond pulses created by soliton self-frequency shift of a 1550-nm fiber-based femtosecond laser together with micro-electro-mechanical system (MEMS) phase spatial light modulator (SLM). We perturb the 1020-segment SLM using an orthogonal Walsh sequence basis set with a modified version of three-point phase shifting interferometry. We show the improvement after aberrations correction in 3-photon signal from fluorescent beads. In addition, we compare the improvement obtained in the same adaptive optical system for 2-, 3- and 4-photon fluorescence using dye pool. We show that signal improvement resulting from aberration correction grows exponentially as a function of the order of nonlinearity. PMID:26698772
Validity of self-reported exposure to shift work.
Härmä, Mikko; Koskinen, Aki; Ropponen, Annina; Puttonen, Sampsa; Karhula, Kati; Vahtera, Jussi; Kivimäki, Mika
2017-03-01
To evaluate the validity of widely used questionnaire items on work schedule using objective registry data as reference. A cohort study of hospital employees who responded to a self-administered questionnaire on work schedule in 2008, 2012 and 2014 and were linked to individual-level pay-roll-based records on work shifts. For predictive validity, leisure-time fatigue was assessed. According to the survey data in 2014 (n=8896), 55% of the day workers had at least 1 year of earlier shift work experience. 8% of the night shift workers changed to day work during the follow-up. Using pay-roll data as reference, questions on 'shift work with night shifts' and 'permanent night work' showed high sensitivity (96% and 90%) and specificity (92% and 97%). Self-reported 'regular day work' showed moderate sensitivity (73%), but high specificity (99%) and 'shift work without night shifts' showed low sensitivity (62%) and moderate specificity (87%). In multivariate logistic regression analysis, the age-adjusted, sex-adjusted and baseline fatigue-adjusted association between 'shift work without night shifts' and leisure-time fatigue was lower for self-reported compared with objective assessment (1.30, 95% CI 0.94 to 1.82, n=1707 vs 1.89, 95% CI 1.06 to 3.39, n=1627). In contrast, shift work with night shifts, compared with permanent day work, was similarly associated with fatigue in the two assessments (2.04, 95% CI 1.62 to 2.57, n=2311 vs 1.82, 95% CI 1.28 to 2.58, n=1804). The validity of self-reported assessment of shift work varies between work schedules. Exposure misclassification in self-reported data may contribute to bias towards the null in shift work without night shifts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Resonant nonlinear ultrasound spectroscopy
Johnson, Paul A.; TenCate, James A.; Guyer, Robert A.; Van Den Abeele, Koen E. A.
2001-01-01
Components with defects are identified from the response to strains applied at acoustic and ultrasound frequencies. The relative resonance frequency shift .vertline..DELTA..function./.function..sub.0.vertline., is determined as a function of applied strain amplitude for an acceptable component, where .function..sub.0 is the frequency of the resonance peak at the lowest amplitude of applied strain and .DELTA..function. is the frequency shift of the resonance peak of a selected mode to determine a reference relationship. Then, the relative resonance frequency shift .vertline..DELTA..function./.function..sub.0 is determined as a function of applied strain for a component under test, where fo .function..sub.0 the frequency of the resonance peak at the lowest amplitude of applied strain and .DELTA..function. is the frequency shift of the resonance peak to determine a quality test relationship. The reference relationship is compared with the quality test relationship to determine the presence of defects in the component under test.
Laser frequency stabilization and shifting by using modulation transfer spectroscopy
NASA Astrophysics Data System (ADS)
Cheng, Bing; Wang, Zhao-Ying; Wu, Bin; Xu, Ao-Peng; Wang, Qi-Yu; Xu, Yun-Fei; Lin, Qiang
2014-10-01
The stabilizing and shifting of laser frequency are very important for the interaction between the laser and atoms. The modulation transfer spectroscopy for the 87Rb atom with D2 line transition F = 2 → F' = 3 is used for stabilizing and shifting the frequency of the external cavity grating feedback diode laser. The resonant phase modulator with electro—optical effect is used to generate frequency sideband to lock the laser frequency. In the locking scheme, circularly polarized pump- and probe-beams are used. By optimizing the temperature of the vapor, the pump- and probe-beam intensity, the laser linewidth of 280 kHz is obtained. Furthermore, the magnetic field generated by a solenoid is added into the system. Therefore the system can achieve the frequency locking at any point in a range of hundreds of megahertz frequency shifting with very low power loss.
Zhang, Shangjian; Wang, Heng; Zou, Xinhai; Zhang, Yali; Lu, Rongguo; Liu, Yong
2015-06-15
An extinction-ratio-independent electrical method is proposed for measuring chirp parameters of Mach-Zehnder electric-optic intensity modulators based on frequency-shifted optical heterodyne. The method utilizes the electrical spectrum analysis of the heterodyne products between the intensity modulated optical signal and the frequency-shifted optical carrier, and achieves the intrinsic chirp parameters measurement at microwave region with high-frequency resolution and wide-frequency range for the Mach-Zehnder modulator with a finite extinction ratio. Moreover, the proposed method avoids calibrating the responsivity fluctuation of the photodiode in spite of the involved photodetection. Chirp parameters as a function of modulation frequency are experimentally measured and compared to those with the conventional optical spectrum analysis method. Our method enables an extinction-ratio-independent and calibration-free electrical measurement of Mach-Zehnder intensity modulators by using the high-resolution frequency-shifted heterodyne technique.
Multi-pulse frequency shifted (MPFS) multiple access modulation for ultra wideband
Nekoogar, Faranak [San Ramon, CA; Dowla, Farid U [Castro Valley, CA
2012-01-24
The multi-pulse frequency shifted technique uses mutually orthogonal short duration pulses o transmit and receive information in a UWB multiuser communication system. The multiuser system uses the same pulse shape with different frequencies for the reference and data for each user. Different users have a different pulse shape (mutually orthogonal to each other) and different transmit and reference frequencies. At the receiver, the reference pulse is frequency shifted to match the data pulse and a correlation scheme followed by a hard decision block detects the data.
Non-occupational physical activity levels of shift workers compared with non-shift workers
Loef, Bette; Hulsegge, Gerben; Wendel-Vos, G C Wanda; Verschuren, W M Monique; Bakker, Marije F; van der Beek, Allard J; Proper, Karin I
2017-01-01
Objectives Lack of physical activity (PA) has been hypothesised as an underlying mechanism in the adverse health effects of shift work. Therefore, our aim was to compare non-occupational PA levels between shift workers and non-shift workers. Furthermore, exposure–response relationships for frequency of night shifts and years of shift work regarding non-occupational PA levels were studied. Methods Data of 5980 non-shift workers and 532 shift workers from the European Prospective Investigation into Cancer and Nutrition-Netherlands (EPIC-NL) were used in these cross-sectional analyses. Time spent (hours/week) in different PA types (walking/cycling/exercise/chores) and intensities (moderate/vigorous) were calculated based on self-reported PA. Furthermore, sports were operationalised as: playing sports (no/yes), individual versus non-individual sports, and non-vigorous-intensity versus vigorous-intensity sports. PA levels were compared between shift workers and non-shift workers using Generalized Estimating Equations and logistic regression. Results Shift workers reported spending more time walking than non-shift workers (B=2.3 (95% CI 1.2 to 3.4)), but shift work was not associated with other PA types and any of the sports activities. Shift workers who worked 1–4 night shifts/month (B=2.4 (95% CI 0.6 to 4.3)) and ≥5 night shifts/month (B=3.7 (95% CI 1.8 to 5.6)) spent more time walking than non-shift workers. No exposure–response relationships were found between years of shift work and PA levels. Conclusions Shift workers spent more time walking than non-shift workers, but we observed no differences in other non-occupational PA levels. To better understand if and how PA plays a role in the negative health consequences of shift work, our findings need to be confirmed in future studies. PMID:27872151
Non-occupational physical activity levels of shift workers compared with non-shift workers.
Loef, Bette; Hulsegge, Gerben; Wendel-Vos, G C Wanda; Verschuren, W M Monique; Vermeulen, Roel C H; Bakker, Marije F; van der Beek, Allard J; Proper, Karin I
2017-05-01
Lack of physical activity (PA) has been hypothesised as an underlying mechanism in the adverse health effects of shift work. Therefore, our aim was to compare non-occupational PA levels between shift workers and non-shift workers. Furthermore, exposure-response relationships for frequency of night shifts and years of shift work regarding non-occupational PA levels were studied. Data of 5980 non-shift workers and 532 shift workers from the European Prospective Investigation into Cancer and Nutrition-Netherlands (EPIC-NL) were used in these cross-sectional analyses. Time spent (hours/week) in different PA types (walking/cycling/exercise/chores) and intensities (moderate/vigorous) were calculated based on self-reported PA. Furthermore, sports were operationalised as: playing sports (no/yes), individual versus non-individual sports, and non-vigorous-intensity versus vigorous-intensity sports. PA levels were compared between shift workers and non-shift workers using Generalized Estimating Equations and logistic regression. Shift workers reported spending more time walking than non-shift workers (B=2.3 (95% CI 1.2 to 3.4)), but shift work was not associated with other PA types and any of the sports activities. Shift workers who worked 1-4 night shifts/month (B=2.4 (95% CI 0.6 to 4.3)) and ≥5 night shifts/month (B=3.7 (95% CI 1.8 to 5.6)) spent more time walking than non-shift workers. No exposure-response relationships were found between years of shift work and PA levels. Shift workers spent more time walking than non-shift workers, but we observed no differences in other non-occupational PA levels. To better understand if and how PA plays a role in the negative health consequences of shift work, our findings need to be confirmed in future studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Symmetry-breaking oscillations in membrane optomechanics
NASA Astrophysics Data System (ADS)
Wurl, C.; Alvermann, A.; Fehske, H.
2016-12-01
We study the classical dynamics of a membrane inside a cavity in the situation where this optomechanical system possesses a reflection symmetry. Symmetry breaking occurs through supercritical and subcritical pitchfork bifurcations of the static fixed-point solutions. Both bifurcations can be observed through variation of the laser-cavity detuning, which gives rise to a boomerang-like fixed-point pattern with hysteresis. The symmetry-breaking fixed points evolve into self-sustained oscillations when the laser intensity is increased. In addition to the analysis of the accompanying Hopf bifurcations we describe these oscillations at finite amplitudes with an ansatz that fully accounts for the frequency shift relative to the natural membrane frequency. We complete our study by following the route to chaos for the membrane dynamics.
[Effect of the night shift work on micturition patterns of nurses].
Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X
2016-02-18
To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.
[Effect of the night shift work on micturition patterns of nurses].
Wang, Q; Hu, H; Liang, C; Wang, J; Xu, K X
2016-08-18
To compare the effects of rotational night shifts on the micturition patterns of female nurses. A total of 58 nurses without lower urinary tract symptoms were recruited, who worked in the Peking University People's Hospital during January and June in 2014. The nurses aged 20-43 years were divided into two groups, the night-shift group (n=28) and the non-shift group (n=30). The alcohol or coffee intaking were forbidden. In the night-shift group, nurses had worked on rotational shifts for at least 6 months. Their average age was (26.75±4.11) years. In the non-shift group, nurses took regular day-time work, whose average age was (27.80±5.60) years. A voiding diary was kept for 7 consecutive days at the end of 6 months, starting 2 days before their night duties until 4 days after completion of their night duties. For comparison, the non-shift group with regular shifts completed a 7-day voiding diary. In the 7-day recording voiding diary, the nurses were required to have the normal intake of liquid about 1 500-2 000 mL/d. The frequency volume charts of nocturia, the 8-hour interval urine production and frequency were compared between the two groups. Nocturia frequency was increased in the night-shift group [0.5 (0-2.4)] compared with the non-shift group [0 (0-2), P=0.02]. The volume of nocturia was increased in the night-shift group [125 mL (0-660 mL)] compared with the non-shift group [0 mL (0-340 mL), P<0.01]. The 8-hour interval indices showed that urine production changed with shift (P<0.01). In the consecutive 7 days, the nocturnal volume of the night-shift group increased on the day after night shift. When the night-shift nurses returned to daytime duty, the volume of urine decreased but nocturnal urine production remained high, and the frequency of nocturia also increased significantly (P<0.05). Compared with the 8-hour interval indices, the night-shift group's voiding volume [(542.35±204.66) mL] and voiding frequency (2.24±0.69) were more than those of the non-shift group at the afternoon time (from 2 pm to 10 pm). During the 8 h interval night time (from 10 pm to 6 am), the volume of nocturia in the night-shift group [(309.74±162.74) mL] was more than that in the non-shift group [(199.38±153.98) mL, P=0.01]; the frequency of nocturia in the night-shift group (1.31±0.52) was increased than that in the non-shift group (0.82±0.55, P<0.01). The rotational shifts affect the micturition patterns of nurses who go through the night shift work, which increases the volume and frequency of the nocturia.
Laser Self-Mixing Fiber Bragg Grating Sensor for Acoustic Emission Measurement.
Liu, Bin; Ruan, Yuxi; Yu, Yanguang; Xi, Jiangtao; Guo, Qinghua; Tong, Jun; Rajan, Ginu
2018-06-16
Fiber Bragg grating (FBG) is considered a good candidate for acoustic emission (AE) measurement. The sensing and measurement in traditional FBG-based AE systems are based on the variation in laser intensity induced by the Bragg wavelength shift. This paper presents a sensing system by combining self-mixing interference (SMI) in a laser diode and FBG for AE measurement, aiming to form a new compact and cost-effective sensing system. The measurement model of the overall system was derived. The performance of the presented system was investigated from both aspects of theory and experiment. The results show that the proposed system is able to measure AE events with high resolution and over a wide dynamic frequency range.
Ohtomo, Takayuki; Sudo, Seiichi; Otsuka, Kenju
2016-09-20
We observed intermittent modulation by scattered light from a single submicrometer particle moving in the flow channel using a self-mixing microchip Yb:YAG laser Doppler velocimeter (LDV) under lateral beam access. The Doppler-shift frequency chirping (i.e., velocity change) was identified in accordance with a particle passage through the beam focus. Single particle counting, which obeys the Poisson distribution, was performed successfully over a long period of time. The experimental results have been reproduced by a numerical simulation. The LDV signal was increased over 20 dB for a 202-nm particle without chirping by collinear beam access with the laser beam axis aligned along the flow direction.
NASA Astrophysics Data System (ADS)
Wang, Q.; Y Zheng, C.; Liu, Z. J.; Xiao, C. Z.; Feng, Q. S.; Zhang, H. C.; He, X. T.
2018-02-01
The effect of the kinetic nonlinear frequency shift (KNFS) on backward stimulated Brillouin scattering (SBS) in homogeneous plasmas and inhomogeneous flowing plasmas is investigated by three-wave coupled-mode equations. When the positive contribution to the KNFS from electrons as well as the negative contribution from ions is included, the net KNFS can become positive at a large electron-ion temperature ratio {{ZT}}e/{T}i. In homogeneous plasmas, KNFS can greatly reduce the SBS reflectivity at low or large {{ZT}}e/{T}i but has a weak effect on SBS at {{ZT}}e/{T}i where the positive frequency shifts from electrons almost cancels out the negative shifts from ions. In inhomogeneous plasmas, the net negative frequency shift can enhance the backward SBS reflectivity for the negative gradient of the plasma flowing, and can suppress the reflectivity for the positive case. On the contrary, the net positive frequency can suppress the reflectivity for the negative case of the flowing gradient and enhance the reflectivity for the positive case. This indicates that the SBS in inhomogeneous flowing plasmas can be controlled by changing the sign of the nonlinear frequency shift.
Tissue specific resonance frequencies of water and metabolites within the human brain
NASA Astrophysics Data System (ADS)
Chadzynski, Grzegorz L.; Bender, Benjamin; Groeger, Adriane; Erb, Michael; Klose, Uwe
2011-09-01
Chemical shift imaging (CSI) without water suppression was used to examine tissue-specific resonance frequencies of water and metabolites within the human brain. The aim was to verify if there are any regional differences in those frequencies and to determine the influence of chemical shift displacement in slice-selection direction. Unsuppressed spectra were acquired at 3 T from nine subjects. Resonance frequencies of water and after water signal removal of total choline, total creatine and NAA were estimated. Furthermore, frequency distances between the water and those resonances were calculated. Results were corrected for chemical shift displacement. Frequency distances between water and metabolites were consistent and greater for GM than for WM. The highest value of WM to GM difference (14 ppb) was observed for water to NAA frequency distance. This study demonstrates that there are tissue-specific differences between frequency distances of water and metabolites. Moreover, the influence of chemical shift displacement in slice-selection direction is showed to be negligible.
Tissue specific resonance frequencies of water and metabolites within the human brain.
Chadzynski, Grzegorz L; Bender, Benjamin; Groeger, Adriane; Erb, Michael; Klose, Uwe
2011-09-01
Chemical shift imaging (CSI) without water suppression was used to examine tissue-specific resonance frequencies of water and metabolites within the human brain. The aim was to verify if there are any regional differences in those frequencies and to determine the influence of chemical shift displacement in slice-selection direction. Unsuppressed spectra were acquired at 3T from nine subjects. Resonance frequencies of water and after water signal removal of total choline, total creatine and NAA were estimated. Furthermore, frequency distances between the water and those resonances were calculated. Results were corrected for chemical shift displacement. Frequency distances between water and metabolites were consistent and greater for GM than for WM. The highest value of WM to GM difference (14ppb) was observed for water to NAA frequency distance. This study demonstrates that there are tissue-specific differences between frequency distances of water and metabolites. Moreover, the influence of chemical shift displacement in slice-selection direction is showed to be negligible. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Vlahos, Loukas; Sprangle, Phillip
1987-01-01
The nonlinear evolution of cyclotron radiation from streaming and gyrating electrons in an external magnetic field is analyzed. The nonlinear dynamics of both the fields and the particles are treated fully relativistically and self-consistently. The model includes a background plasma and electrostatic effects. The analytical and numerical results show that a substantial portion of the beam particle energy can be converted to electromagnetic wave energy at frequencies far above the electron cyclotron frequency. In general, the excited radiation can propagate parallel to the magnetic field and, hence, escape gyrothermal absorption at higher cyclotron harmonics. The high-frequency Doppler-shifted cyclotron instability can have saturation efficiencies far higher than those associated with well-known instabilities of the electron cyclotron maser type. Although the analysis is general, the possibility of using this model to explain the intense radio emission observed from the sun is explored in detail.
Tailoring of the partial magnonic gap in three-dimensional magnetoferritin-based magnonic crystals
NASA Astrophysics Data System (ADS)
Mamica, S.
2013-07-01
We investigate theoretically the use of magnetoferritin nanoparticles, self-assembled in the protein crystallization process, as the basis for the realization of 3D magnonic crystals in which the interparticle space is filled with a ferromagnetic material. Using the plane wave method we study the dependence of the width of the partial band gap and its central frequency on the total magnetic moment of the magnetoferritin core and the lattice constant of the magnetoferritin crystal. We show that by adjusting the combination of these two parameters the partial gap can be tailored in a wide frequency range and shifted to sub-terahertz frequencies. Moreover, the difference in the width of the partial gap for spin waves propagating in planes parallel and perpendicular to the external field allows for switching on and off the partial magnonic gap by changing the direction of the applied field.
High-order Stokes generation in a KTP Raman laser pumped by a passively Q-switched ND:YLF laser
NASA Astrophysics Data System (ADS)
Wang, Maorong; Zhong, Kai; Mei, Jialin; Guo, Shibei; Xu, Degang; Yao, Jianquan
2015-12-01
High-order Stokes wave was observed in an x-cut KTP crystal based on stimulated Raman scattering (SRS) pumped by a passively Q-switched Nd:YLF laser with a Cr4+:YAG saturable absorber. Output spectra including the fundamental wave at 1047 nm and six Stokes wavelengths at 1077 nm, 1110 nm, 1130 nm, 1143 nm, 1164 nm, 1180 nm based on two Raman frequency shift at 267.4 cm-1 and 693.0 cm-1 were obtained simultaneously. We also detected green light generation with output power of 12 mW from self frequency mixing in the KTP crystal. The maximum total output power reached 452 mW at the repetition frequency of 8.1 kHz, corresponding to the optical-to-optical conversion efficiency of 4.61% and pump-to-Raman conversion efficiency of 3.6%.
NASA Technical Reports Server (NTRS)
vonGierke, Henning E.; Parker, Donald E.
1993-01-01
Human graviceptors, located in the trunk by Mittelstaedt probably transduce acceleration by abdominal viscera motion. As demonstrated previously in biodynamic vibration and impact tolerance research the thoraco-abdominal viscera exhibit a resonance at 4 to 6 Hz. Behavioral observations and mechanical models of otolith graviceptor response indicate a phase shift increasing with frequency between 0.01 and O.5 Hz. Consequently the potential exists for intermodality sensory conflict between vestibular and visceral graviceptor signals at least at the mechanical receptor level. The frequency range of this potential conflict corresponds with the primary frequency range for motion sickness incidence in transportation, in subjects rotated about Earth-horizontal axes (barbecue spit stimulation) and in periodic parabolic flight microgravity research and also for erroneous perception of vertical oscillations in helicopters. We discuss the implications of this hypothesis for previous self motion perception research and suggestions for various future studies.
Effect of Shift Work on Nocturia.
Kim, Jin Wook
2016-01-01
To identify the circadian sensitive component of nocturia by comparing nocturia in patients who voluntarily choose a disrupted circadian rhythm, that is, shift workers, with those who maintain normal day-night cycles. Between 2011 and 2013, a total of 1741 untreated patients, 1376 nonshift workers and 365 shift workers, were compared for nocturia indices based on frequency volume charts (FVCs). General linear model of 8-hour interval urine production and frequency were compared between FVCs of nonshift workers, FVCs of night-shift workers, and FVCs of day-shift workers. Nocturia frequency was increased in the night-shift workers (2.38 ± 1.44) compared with nonshift workers (2.18 ± 1.04) (P <.01). Whereas nocturnal polyuria index did not increase significantly (0.33 ± 0.19 for night-shift workers, 0.34 ± 0.13 for nonshift workers, P = .24), nocturnal bladder capacity index increased significantly (1.41 ± 1.06 for night-shift workers, 1.26 ± 0.92 for nonshift workers, P <.01). Eight-hour interval indices show that urine production changed with shift (P <.01), whereas voiding frequency remains unchanged despite shift changes (P = .35). Patients in alternating work shifts showed increased nocturia, especially during their night shift. These changes tended to be more associated with decreased nocturnal bladder capacity than increased nocturnal polyuria. Copyright © 2015 Elsevier Inc. All rights reserved.
Influence of rate of change of frequency on the overall pitch of frequency-modulated tones.
Gockel, H; Moore, B C; Carlyon, R P
2001-02-01
The mechanism(s) determining pitch may assign less weight to portions of a sound where the frequency is changing rapidly. The present experiments explored the possible effect of this on the overall pitch of frequency-modulated sounds. Pitch matches were obtained between an adjustable unmodulated sinusoid and a sinusoidal carrier that was frequency modulated using a highly asymmetric function with the form of a repeating U or inverted U shaped function. The amplitude was constant during the 400-ms presentation time of each stimulus, except for 10-ms raised-cosine onset and offset ramps. In experiment 1, the carrier level was 50 dB SPL and the geometric mean of the instantaneous frequency of the modulated carrier, fc, was either 0.5, 1, 2, or 8 kHz. The modulation rate (fm) was 5, 10, or 20 Hz. The overall depth (maximum to minimum) of the FM was 8% of fc. For all carrier frequencies, the matched frequency was shifted away from the mean carrier frequency, downwards for the U shaped function stimuli and upwards for the repeated inverted U shaped function stimuli. The shift was typically slightly greater than 1% of fc, and did not vary markedly with fc. The effect of fm was small, but there was a trend for the shifts to decrease with increasing fm for fc = 0.5 kHz and to increase with increasing fm for fc = 2 kHz. In experiment 2, the carrier level was reduced to 20 dB SL and matches were obtained only for fc = 2 kHz. Shifts in matched frequency of about 1% were still observed, but the trend for the shifts to increase with increasing fm no longer occurred. In experiment 3, matches were obtained for a 4-kHz carrier at 50 dB SPL. Shifts of about 1% again occurred, which did not vary markedly with fm. The shifts in matched frequency observed in all three experiments are not predicted by models based on the amplitude- or intensity-weighted average of instantaneous frequency (EWAIF or IWAIF). The shifts (and the pitch shifts observed earlier for two-tone complexes and for stimuli with simultaneous AM and FM) are consistent with a model based on the assumption that the overall pitch of a frequency-modulated sound is determined from a weighted average of period estimates, with the weight attached to a given estimate being inversely related to the short-term rate of change of period and directly related to a compressive function of the amplitude.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise.
Nechaev, Dmitry I; Milekhina, Olga N; Supin, Alexander Ya
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels.
Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise
Nechaev, Dmitry I.; Milekhina, Olga N.; Supin, Alexander Ya.
2015-01-01
The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels. PMID:26462066
Building a good initial model for full-waveform inversion using frequency shift filter
NASA Astrophysics Data System (ADS)
Wang, Guanchao; Wang, Shangxu; Yuan, Sanyi; Lian, Shijie
2018-05-01
Accurate initial model or available low-frequency data is an important factor in the success of full waveform inversion (FWI). The low-frequency helps determine the kinematical relevant components, low-wavenumber of the velocity model, which are in turn needed to avoid FWI trap in local minima or cycle-skipping. However, in the field, acquiring data that <5 Hz is a challenging and expensive task. We attempt to find the common point of low- and high-frequency signal, then utilize the high-frequency data to obtain the low-wavenumber velocity model. It is well known that the instantaneous amplitude envelope of a wavelet is invariant under frequency shift. This means that resolution is constant for a given frequency bandwidth, and independent of the actual values of the frequencies. Based on this property, we develop a frequency shift filter (FSF) to build the relationship between low- and high-frequency information with a constant frequency bandwidth. After that, we can use the high-frequency information to get a plausible recovery of the low-wavenumber velocity model. Numerical results using synthetic data from the Marmousi and layer model demonstrate that our proposed envelope misfit function based on the frequency shift filter can build an initial model with more accurate long-wavelength components, when low-frequency signals are absent in recorded data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tu, Guangde; Rinkevicius, Zilvinas; Vahtras, Olav
We outline an approach within time-dependent density functional theory that predicts x-ray spectra on an absolute scale. The approach rests on a recent formulation of the resonant-convergent first-order polarization propagator [P. Norman et al., J. Chem. Phys. 123, 194103 (2005)] and corrects for the self-interaction energy of the core orbital. This polarization propagator approach makes it possible to directly calculate the x-ray absorption cross section at a particular frequency without explicitly addressing the excited-state spectrum. The self-interaction correction for the employed density functional accounts for an energy shift of the spectrum, and fully correlated absolute-scale x-ray spectra are thereby obtainedmore » based solely on optimization of the electronic ground state. The procedure is benchmarked against experimental spectra of a set of small organic molecules at the carbon, nitrogen, and oxygen K edges.« less
Deshmukh, Sanket A; Solomon, Lee A; Kamath, Ganesh; Fry, H Christopher; Sankaranarayanan, Subramanian K R S
2016-08-24
Understanding the role of water in governing the kinetics of the self-assembly processes of amphiphilic peptides remains elusive. Here, we use a multistage atomistic-coarse-grained approach, complemented by circular dichroism/infrared spectroscopy and dynamic light scattering experiments to highlight the dual nature of water in driving the self-assembly of peptide amphiphiles (PAs). We show computationally that water cage formation and breakage near the hydrophobic groups control the fusion dynamics and aggregation of PAs in the micellar stage. Simulations also suggest that enhanced structural ordering of vicinal water near the hydrophilic amino acids shifts the equilibrium towards the fibre phase and stimulates structure and order during the PA assembly into nanofibres. Experiments validate our simulation findings; the measured infrared O-H bond stretching frequency is reminiscent of an ice-like bond which suggests that the solvated water becomes increasingly ordered with time in the assembled peptide network, thus shedding light on the role of water in a self-assembly process.
Manning, Victoria; Teo, Hui Chin; Guo, Song; Wong, Kim Eng; Li, Ting-Kai
2016-01-28
The prevalence of alcohol use disorders in Asia is increasing and relapse among treated populations remains the norm, not the exception. The extent to which cognitive impairment influences clinical outcome remains unclear, with research dominated by studies of Caucasian populations. This study examines behavioral and self-reported cognitive functioning in detoxified alcohol-dependent (AD) patients in Singapore and its association with outcome. The cognitive performance of 30 recently-detoxified AD inpatients and 30 demographically-matched controls was compared using visuospatial memory, working memory, set-shifting, planning and reflection impulsivity tests of the CANTAB®, and self-reported dysexecutive symptoms and everyday cognitive difficulties. Patients' alcohol use and self-reported cognitive functioning were reassessed 3-months post-discharge. Compared to matched controls, AD inpatients exhibited significantly poorer fluid intelligence, visuospatial memory, working memory, set-shifting flexibility and planning/organization, but not reflection impulsivity. In support of Western studies, a significant proportion (three-quarters) were "clinically impaired" on subtests. Significant reductions were observed in alcohol units, frequency and dependency scores at follow-up, though improvements in self-reported cognitive functioning were limited to abstainers. Baseline cognitive performance did not differentiate those who had abstained from alcohol and relapsed at follow-up. Memory and executive functioning impairments were evident among Asian AD patients alongside self-reported cognitive difficulties, thus cognitively demanding psychological interventions may have limited impact during early detoxification. Future studies can build on these findings, with larger samples and measurement of moderating and mediating factors to extend our understanding of how cognitive impairment influences outcome.
NASA Technical Reports Server (NTRS)
Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.
1982-01-01
Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.
Implications of solar p-mode frequency shifts
NASA Technical Reports Server (NTRS)
Goldreich, Peter; Murray, Norman; Willette, Gregory; Kumar, Pawan
1991-01-01
An expression is derived that relates solar p-mode frequency shifts to changes in the entropy and magnetic field of the sun. The frequency variations result from changes in path length and propagation speed. Path length changes dominate for entropy perturbations, and propagation speed changes dominate for most types of magnetic field peturbations. The p-mode frequencies increased along with solar activity between 1986 and 1989; these frequency shifts exhibited a rapid rise with increasing frequency followed by a precipitous drop. The positive component of the shifts can be accounted for by variations of the mean square magnetic field strength in the vicinity of the photosphere. The magnetic stress perturbation decays above the top of the convection zone on a length scale comparable to the pressure scale height and grows gradually with depth below. The presence of a resonance in the chromospheric cavity means that the transition layer maintains enough coherence to partially reflect acoustic waves even near cycle maximum.
Miasnikov, Alexandre A; Weinberger, Norman M
2012-11-01
Experience often does not produce veridical memory. Understanding false attribution of events constitutes an important problem in memory research. "Peak shift" is a well-characterized, controllable phenomenon in which human and animal subjects that receive reinforcement associated with one sensory stimulus later respond maximally to another stimulus in post-training stimulus generalization tests. Peak shift ordinarily develops in discrimination learning (reinforced CS+, unreinforced CS-) and has long been attributed to the interaction of an excitatory gradient centered on the CS+ and an inhibitory gradient centered on the CS-; the shift is away from the CS-. In contrast, we have obtained peak shifts during single tone frequency training, using stimulation of the cholinergic nucleus basalis (NB) to implant behavioral memory into the rat. As we also recorded cortical activity, we took the opportunity to investigate the possible existence of a neural frequency gradient that could account for behavioral peak shift. Behavioral frequency generalization gradients (FGGs, interruption of ongoing respiration) were determined twice before training while evoked potentials were recorded from the primary auditory cortex (A1), to obtain a baseline gradient of "habituatory" neural decrement. A post-training behavioral FGG obtained 24h after three daily sessions of a single tone paired with NB stimulation (200 trials/day) revealed a peak shift. The peak of the FGG was at a frequency lower than the CS while the cortical inhibitory gradient was at a frequency higher than the CS frequency. Further analysis indicated that the frequency location and magnitude of the gradient could account for the behavioral peak shift. These results provide a neural basis for a systematic case of memory misattribution and may provide an animal model for the study of the neural bases of a type of "false memory". Published by Elsevier Inc.
Decoherence and Collisional Frequency Shifts of Trapped Bosons and Fermions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibble, Kurt; LNE-SYRTE, Observatoire de Paris, 75014 Paris
2009-09-11
We perform exact calculations of collisional frequency shifts for several fermions or bosons using a singlet and triplet basis for pairs of particles. The 'factor of 2 controversy' for bosons becomes clear - the factor is always 2. Decoherence is described by singlet states and they are unaffected by spatially uniform clock fields. Spatial variations are critical, especially for fermions which were previously thought to be immune to collision shifts. The spatial variations lead to decoherence and a novel frequency shift that is not proportional to the partial density of internal states.
NASA Astrophysics Data System (ADS)
McDowell, Sean A. C.
2017-04-01
An MP2 computational study of model hydrogen-bonded pyrrole⋯YZ (YZ = NH3, NCH, BF, CO, N2, OC, FB) complexes was undertaken in order to examine the variation of the Nsbnd H bond length change and its associated vibrational frequency shift. The chemical hardness of Y, as well as the YZ dipole moment, were found to be important parameters in modifying the bond length change/frequency shift. The basis set effect on the computed properties was also assessed. A perturbative model, which accurately reproduced the ab initio Nsbnd H bond length changes and frequency shifts, was useful in rationalizing the observed trends.
NASA Astrophysics Data System (ADS)
Kobayashi, Hiroaki; Gotoda, Hiroshi; Tachibana, Shigeru; Yoshida, Seiji
2017-12-01
We conduct an experimental study using time series analysis based on symbolic dynamics to detect a precursor of frequency-mode-shift during thermoacoustic combustion oscillations in a staged aircraft engine model combustor. With increasing amount of the main fuel, a significant shift in the dominant frequency-mode occurs in noisy periodic dynamics, leading to a notable increase in oscillation amplitudes. The sustainment of noisy periodic dynamics during thermoacoustic combustion oscillations is clearly shown by the multiscale complexity-entropy causality plane in terms of statistical complexity. A modified version of the permutation entropy allows us to detect a precursor of the frequency-mode-shift before the amplification of pressure fluctuations.
Hunting for dark matter with ultra-stable fibre as frequency delay system.
Yang, Wanpeng; Li, Dawei; Zhang, Shuangyou; Zhao, Jianye
2015-07-10
Many cosmological observations point towards the existence of dark-matter(DM) particles and consider them as the main component of the matter content of the universe. The goal of revealing the nature of dark-matter has triggered the development of new, extremely sensitive detectors. It has been demonstrated that the frequencies and phases of optical clock have a transient shift during the DMs' arrival due to the DM-SM(Standard Model) coupling. A simple, reliable and feasible experimental scheme is firstly proposed in this paper, based on "frequency-delay system" to search dark-matter by "self-frequency comparison" of an optical clock. During the arrival of a dark-matter, frequency discrepancy is expected between two signals with a short time difference(~ms) of the same optical clock to exhibit the interaction between atoms and dark-matter. Furthermore, this process can determine the exact position of dark-matter when it is crossing the optical clocks, therefore a network of detecting stations located in different places is recommended to reduce the misjudgment risk to an acceptable level.
Hunting for dark matter with ultra-stable fibre as frequency delay system
Yang, Wanpeng; Li, Dawei; Zhang, Shuangyou; Zhao, Jianye
2015-01-01
Many cosmological observations point towards the existence of dark-matter(DM) particles and consider them as the main component of the matter content of the universe. The goal of revealing the nature of dark-matter has triggered the development of new, extremely sensitive detectors. It has been demonstrated that the frequencies and phases of optical clock have a transient shift during the DMs’ arrival due to the DM-SM(Standard Model) coupling. A simple, reliable and feasible experimental scheme is firstly proposed in this paper, based on “frequency-delay system” to search dark-matter by “self-frequency comparison” of an optical clock. During the arrival of a dark-matter, frequency discrepancy is expected between two signals with a short time difference(~ms) of the same optical clock to exhibit the interaction between atoms and dark-matter. Furthermore, this process can determine the exact position of dark-matter when it is crossing the optical clocks, therefore a network of detecting stations located in different places is recommended to reduce the misjudgment risk to an acceptable level. PMID:26159113
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sago, Norichika; Barack, Leor; Detweiler, Steven
2008-12-15
Recently, two independent calculations have been presented of finite-mass ('self-force') effects on the orbit of a point mass around a Schwarzschild black hole. While both computations are based on the standard mode-sum method, they differ in several technical aspects, which makes comparison between their results difficult--but also interesting. Barack and Sago [Phys. Rev. D 75, 064021 (2007)] invoke the notion of a self-accelerated motion in a background spacetime, and perform a direct calculation of the local self-force in the Lorenz gauge (using numerical evolution of the perturbation equations in the time domain); Detweiler [Phys. Rev. D 77, 124026 (2008)] describesmore » the motion in terms a geodesic orbit of a (smooth) perturbed spacetime, and calculates the metric perturbation in the Regge-Wheeler gauge (using frequency-domain numerical analysis). Here we establish a formal correspondence between the two analyses, and demonstrate the consistency of their numerical results. Specifically, we compare the value of the conservative O({mu}) shift in u{sup t} (where {mu} is the particle's mass and u{sup t} is the Schwarzschild t component of the particle's four-velocity), suitably mapped between the two orbital descriptions and adjusted for gauge. We find that the two analyses yield the same value for this shift within mere fractional differences of {approx}10{sup -5}-10{sup -7} (depending on the orbital radius)--comparable with the estimated numerical error.« less
Local time distribution of the SSC-associated HF-Doppler frequency shifts
NASA Technical Reports Server (NTRS)
Kikuchi, T.; Sugiuchi, H.; Ishimine, T.
1985-01-01
The HF-Doppler frequency shift observed at the storm's sudden commencement is composed of a frequency increase (+) and decrease (-), and classified into four types, SCF(+ -), SCF(- +), SCF(+) and SCF(-). Since the latter two types are special cases of the former two types, two different kinds of electrical field exist in the F region and cause the ExB drift motion of plasma. HUANG (1976) interpreted the frequency increase of SCF(+ -) as due to the westward induction electric field proportional to delta H/ delta t and the succeeding frequency decrease due to the eastward conduction electric field which produces ionospheric currents responsible for the magnetic increase on the ground. In spite of his success in interpreting the SCF(+ -), some other interpretations are needed for the explanation of the whole set of SCF's, particularly SCF(- +). Local time distributions of the SCF's are derived from 41 SCF's which are observed on the HF standard signal (JJY) as received in Okinawa (path length =1600 km) and Kokubunji (60 km). It is shown that the SCF(+ -) appears mainly during the day, whereas the SCF(- +) is observed during the night. The results indicate that the preliminary frequency shift (+) of SCF(+ -) and (-) of SCF(- +) is caused by a westward electric field in the dayside hemisphere, while by an eastward electric field in the nightside hemisphere. The main frequency shift (-) of SCF(+ -) and (+) of SCF(- +) is caused by the reversed electric field. Consequently, the preliminary frequency shift is caused by the dusk-to-dawn electric field, while the main frequency shift by the dawn-to-dusk electric field.
Plasma modification of spoof plasmon propagation along metamaterial-air interfaces
NASA Astrophysics Data System (ADS)
Lee, R.; Wang, B.; Cappelli, M. A.
2017-12-01
We report on measurements of the shift in resonance frequency of "spoof" surface plasmon polariton propagation along a 2-D metamaterial slow-wave structure induced by a gaseous plasma near the metamaterial/air interface. A transmission line circuit model for the metamaterial structure interprets the introduction of a plasma as a decrease in unit cell capacitance, causing a shift in the plasmon dispersion to higher frequency. We show through simulations and experiments that the effects of this shift at the resonance frequency and attenuation below and above resonance depend on the plasma density. The shifts recorded experimentally are small owing to the low plasma densities generated near the structure, ˜ 10 11 cm - 3 , but simulations show that a shift of ˜ 3 % of the resonance frequency can be generated at plasma densities of ˜ 10 12 cm - 3 .
Low-Light-Shift Cesium Fountain without Mechanical Shutters
NASA Technical Reports Server (NTRS)
Enzer, Daphna
2008-01-01
A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.
Blue and red shifted temperature dependence of implicit phonon shifts in graphene
NASA Astrophysics Data System (ADS)
Mann, Sarita; Jindal, V. K.
2017-07-01
We have calculated the implicit shift for various modes of frequency in a pure graphene sheet. Thermal expansion and Grüneisen parameter which are required for implicit shift calculation have already been studied and reported. For this calculation, phonon frequencies are obtained using force constants derived from dynamical matrix calculated using VASP code where the density functional perturbation theory (DFPT) is used in interface with phonopy software. The implicit phonon shift shows an unusual behavior as compared to the bulk materials. The frequency shift is large negative (red shift) for ZA and ZO modes and the value of negative shift increases with increase in temperature. On the other hand, blue shift arises for all other longitudinal and transverse modes with a similar trend of increase with increase in temperature. The q dependence of phonon shifts has also been studied. Such simultaneous red and blue shifts in transverse or out plane modes and surface modes, respectively leads to speculation of surface softening in out of plane direction in preference to surface melting.
3D measurement using combined Gray code and dual-frequency phase-shifting approach
NASA Astrophysics Data System (ADS)
Yu, Shuang; Zhang, Jing; Yu, Xiaoyang; Sun, Xiaoming; Wu, Haibin; Liu, Xin
2018-04-01
The combined Gray code and phase-shifting approach is a commonly used 3D measurement technique. In this technique, an error that equals integer multiples of the phase-shifted fringe period, i.e. period jump error, often exists in the absolute analog code, which can lead to gross measurement errors. To overcome this problem, the present paper proposes 3D measurement using a combined Gray code and dual-frequency phase-shifting approach. Based on 3D measurement using the combined Gray code and phase-shifting approach, one set of low-frequency phase-shifted fringe patterns with an odd-numbered multiple of the original phase-shifted fringe period is added. Thus, the absolute analog code measured value can be obtained by the combined Gray code and phase-shifting approach, and the low-frequency absolute analog code measured value can also be obtained by adding low-frequency phase-shifted fringe patterns. Then, the corrected absolute analog code measured value can be obtained by correcting the former by the latter, and the period jump errors can be eliminated, resulting in reliable analog code unwrapping. For the proposed approach, we established its measurement model, analyzed its measurement principle, expounded the mechanism of eliminating period jump errors by error analysis, and determined its applicable conditions. Theoretical analysis and experimental results show that the proposed approach can effectively eliminate period jump errors, reliably perform analog code unwrapping, and improve the measurement accuracy.
Reversal of orbital angular momentum arising from an extreme Doppler shift.
Gibson, Graham M; Toninelli, Ermes; Horsley, Simon A R; Spalding, Gabriel C; Hendry, Euan; Phillips, David B; Padgett, Miles J
2018-04-10
The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes "negative." In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at [Formula: see text]100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the "negative frequency" regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. Copyright © 2018 the Author(s). Published by PNAS.
Shifts in Teaching Motivation and Sense of Self-as-Teacher in Initial Teacher Education
ERIC Educational Resources Information Center
Tang, Sylvia Y. F.; Cheng, May M. H.; Cheng, Annie Y. N.
2014-01-01
This article presents four student teacher cases using an examination of the nature of shifts in student teachers' motivation for choosing teaching as a career in relation to the development of their sense of self-as-teacher. The analysis relates positive and negative shifts in teaching motivation and sense of self-as-teacher to variation in…
Astrometric "Core-shifts" at the Highest Frequencies
NASA Technical Reports Server (NTRS)
Rioja, Maria; Dodson, Richard
2010-01-01
We discuss the application of a new VLBI astrometric method named "Source/Frequency Phase Referencing" to measurements of "core-shifts" in radio sources used for geodetic observations. We detail the reasons that astrometrical observations of 'core-shifts' have become critical in the era of VLBI2010. We detail how this new method allows the problem to be addressed at the highest frequencies and outline its superior compensation of tropospheric errors.
Automatic oscillator frequency control system
NASA Technical Reports Server (NTRS)
Smith, S. F. (Inventor)
1985-01-01
A frequency control system makes an initial correction of the frequency of its own timing circuit after comparison against a frequency of known accuracy and then sequentially checks and corrects the frequencies of several voltage controlled local oscillator circuits. The timing circuit initiates the machine cycles of a central processing unit which applies a frequency index to an input register in a modulo-sum frequency divider stage and enables a multiplexer to clock an accumulator register in the divider stage with a cyclical signal derived from the oscillator circuit being checked. Upon expiration of the interval, the processing unit compares the remainder held as the contents of the accumulator against a stored zero error constant and applies an appropriate correction word to a correction stage to shift the frequency of the oscillator being checked. A signal from the accumulator register may be used to drive a phase plane ROM and, with periodic shifts in the applied frequency index, to provide frequency shift keying of the resultant output signal. Interposition of a phase adder between the accumulator register and phase plane ROM permits phase shift keying of the output signal by periodic variation in the value of a phase index applied to one input of the phase adder.
NASA Astrophysics Data System (ADS)
Salabert, D.; Régulo, C.; Pérez Hernández, F.; García, R. A.
2018-04-01
The variations of the frequencies of the low-degree acoustic oscillations in the Sun induced by magnetic activity show a dependence on radial order. The frequency shifts are observed to increase towards higher-order modes to reach a maximum of about 0.8 μHz over the 11-yr solar cycle. A comparable frequency dependence is also measured in two other main sequence solar-like stars, the F-star HD 49933, and the young 1 Gyr-old solar analog KIC 10644253, although with different amplitudes of the shifts of about 2 μHz and 0.5 μHz, respectively. Our objective here is to extend this analysis to stars with different masses, metallicities, and evolutionary stages. From an initial set of 87 Kepler solar-like oscillating stars with known individual p-mode frequencies, we identify five stars showing frequency shifts that can be considered reliable using selection criteria based on Monte Carlo simulations and on the photospheric magnetic activity proxy Sph. The frequency dependence of the frequency shifts of four of these stars could be measured for the l = 0 and l = 1 modes individually. Given the quality of the data, the results could indicate that a physical source of perturbation different from that in the Sun is dominating in this sample of solar-like stars.
Two-phase charge-coupled device
NASA Technical Reports Server (NTRS)
Kosonocky, W. F.; Carnes, J. E.
1973-01-01
A charge-transfer efficiency of 99.99% per stage was achieved in the fat-zero mode of operation of 64- and 128-stage two-phase charge-coupled shift registers at 1.0-MHz clock frequency. The experimental two-phase charge-coupled shift registers were constructed in the form of polysilicon gates overlapped by aluminum gates. The unidirectional signal flow was accomplished by using n-type substrates with 0.5 to 1.0 ohm-cm resistivity in conjunction with a channel oxide thickness of 1000 A for the polysilicon gates and 3000 A for the aluminum gates. The operation of the tested shift registers with fat zero is in good agreement with the free-charge transfer characteristics expected for the tested structures. The charge-transfer losses observed when operating the experimental shift registers without the fat zero are attributed to fast interface state trapping. The analytical part of the report contains a review backed up by an extensive appendix of the free-charge transfer characteristics of CCD's in terms of thermal diffusion, self-induced drift, and fringing field drift. Also, a model was developed for the charge-transfer losses resulting from charge trapping by fast interface states. The proposed model was verified by the operation of the experimental two-phase charge-coupled shift registers.
The shift-invariant discrete wavelet transform and application to speech waveform analysis.
Enders, Jörg; Geng, Weihua; Li, Peijun; Frazier, Michael W; Scholl, David J
2005-04-01
The discrete wavelet transform may be used as a signal-processing tool for visualization and analysis of nonstationary, time-sampled waveforms. The highly desirable property of shift invariance can be obtained at the cost of a moderate increase in computational complexity, and accepting a least-squares inverse (pseudoinverse) in place of a true inverse. A new algorithm for the pseudoinverse of the shift-invariant transform that is easier to implement in array-oriented scripting languages than existing algorithms is presented together with self-contained proofs. Representing only one of the many and varied potential applications, a recorded speech waveform illustrates the benefits of shift invariance with pseudoinvertibility. Visualization shows the glottal modulation of vowel formants and frication noise, revealing secondary glottal pulses and other waveform irregularities. Additionally, performing sound waveform editing operations (i.e., cutting and pasting sections) on the shift-invariant wavelet representation automatically produces quiet, click-free section boundaries in the resulting sound. The capabilities of this wavelet-domain editing technique are demonstrated by changing the rate of a recorded spoken word. Individual pitch periods are repeated to obtain a half-speed result, and alternate individual pitch periods are removed to obtain a double-speed result. The original pitch and formant frequencies are preserved. In informal listening tests, the results are clear and understandable.
The shift-invariant discrete wavelet transform and application to speech waveform analysis
NASA Astrophysics Data System (ADS)
Enders, Jörg; Geng, Weihua; Li, Peijun; Frazier, Michael W.; Scholl, David J.
2005-04-01
The discrete wavelet transform may be used as a signal-processing tool for visualization and analysis of nonstationary, time-sampled waveforms. The highly desirable property of shift invariance can be obtained at the cost of a moderate increase in computational complexity, and accepting a least-squares inverse (pseudoinverse) in place of a true inverse. A new algorithm for the pseudoinverse of the shift-invariant transform that is easier to implement in array-oriented scripting languages than existing algorithms is presented together with self-contained proofs. Representing only one of the many and varied potential applications, a recorded speech waveform illustrates the benefits of shift invariance with pseudoinvertibility. Visualization shows the glottal modulation of vowel formants and frication noise, revealing secondary glottal pulses and other waveform irregularities. Additionally, performing sound waveform editing operations (i.e., cutting and pasting sections) on the shift-invariant wavelet representation automatically produces quiet, click-free section boundaries in the resulting sound. The capabilities of this wavelet-domain editing technique are demonstrated by changing the rate of a recorded spoken word. Individual pitch periods are repeated to obtain a half-speed result, and alternate individual pitch periods are removed to obtain a double-speed result. The original pitch and formant frequencies are preserved. In informal listening tests, the results are clear and understandable. .
Kubo, Tatsuhiko; Maruyama, Takashi; Shirane, Kiyoyumi; Otomo, Hajime; Matsumoto, Tetsuro; Oyama, Ichiro
2008-03-01
In 1999, the Japanese Law on Equal Employment Opportunity and Conditions was amended and the previous prohibition of the assignment of female workers to night work was abolished. Subsequently, the number of female shift workers has been increasing in Japan, necessitating greater attention to the health care of this population. The aim of the current study is to evaluate the relationship between anxiety expressed about starting three-shift work and background characteristics among female workers who were being assigned to three-shift work for the first time. The subjects were 38 middle-aged female workers (age range: 44 to 59 years) who were working at a chemical plant. The women completed a self-administered questionnaire before starting three-shift work. Levels of anxiety about starting three-shift work were assessed by the question 'Do you feel anxious about starting three-shift work?' The available responses were: 'Very agree', 'Considerably agree', 'Rather agree', 'Slightly agree' and 'Not agree at all', and 63% of the subjects gave one of the first two answers, which were defined as indicating anxiety. We also acquired information regarding lifestyle and occupation for each subject, including the following factors: frequency of breakfast consumption, subjective sleep insufficiency, previous experience of similar work before beginning shift work, previous experience of two-shift work, and responsibility for household duties. In the study, we found a marginally statistically significant trend association between frequent breakfast consumption and anxiety about starting three-shift work (P(trend) = 0.09). Anxiety was also high among subjects with sleep disorders, especially those suffering from subjective sleep insufficiency (P = 0.08). Due to the small study population, these results should be interpreted with caution and confirmed by future studies.
Treatment of primary vaginismus: a new perspective.
Shaw, J
1994-01-01
This paper challenges the efficacy of a cognitive-behavioral treatment model for women with primary vaginismus and proposes a conceptual shift from a focus on behavior to a focus on differentiation. Primary vaginismus is viewed as a somatic boundary, a symbolic description of an opportunity for differentiation. Four relevant themes are considered: 1) mastery versus incompetence; 2) autonomy versus dependence; 3) boundary versus fusion; and 4) the effect on the therapy of the therapist's level of differentiation. Change at this particular time in history involves shifts in clinical focus from sexual frequency to quality, from performance to experience, from compliance to mastery, and from utilization function to sexual potential. A case is made for sexual competence based on self-competence instead of on behavior. A reevaluation of what constitutes success, both behavioral and developmental, proposes an increase in differentiation in addition to symptom relief.
The ac stark shift and space-borne rubidium atomic clocks
NASA Astrophysics Data System (ADS)
Formichella, V.; Camparo, J.; Sesia, I.; Signorile, G.; Galleani, L.; Huang, M.; Tavella, P.
2016-11-01
Due to its small size, low weight, and low power consumption, the Rb atomic frequency standard (RAFS) is routinely the first choice for atomic timekeeping in space. Consequently, though the device has very good frequency stability (rivaling passive hydrogen masers), there is interest in uncovering the fundamental processes limiting its long-term performance, with the goal of improving the device for future space systems and missions. The ac Stark shift (i.e., light shift) is one of the more likely processes limiting the RAFS' long-term timekeeping ability, yet its manifestation in the RAFS remains poorly understood. In part, this comes from the fact that light-shift induced frequency fluctuations must be quantified in terms of the RAFS' light-shift coefficient and the output variations in the RAFS' rf-discharge lamp, which is a nonlinear inductively-couple plasma (ICP). Here, we analyze the light-shift effect for a family of 10 on-orbit Block-IIR GPS RAFS, examining decade-long records of their on-orbit frequency and rf-discharge lamp fluctuations. We find that the ICP's light intensity variations can take several forms: deterministic aging, jumps, ramps, and non-stationary noise, each of which affects the RAFS' frequency via the light shift. Correlating these light intensity changes with RAFS frequency changes, we estimate the light-shift coefficient, κLS, for the family of RAFS: κLS = -(1.9 ± 0.3) × 10-12/%. The 16% family-wide variation in κLS indicates that while each RAFS may have its own individual κLS, the variance of κLS among similarly designed RAFS can be relatively small. Combining κLS with our estimate of the ICP light intensity's non-stationary noise, we find evidence that random-walk frequency noise in high-quality space-borne RAFS is strongly influenced by the RAFS' rf-discharge lamp via the light shift effect.
Kapuscinski, Martin; Agthe, Michael; Bergström, Lennart
2018-07-15
Self-assembly of nanoparticles into superlattices can be used to create hierarchically structured materials with tailored functions. We have used the surface sensitive quartz crystal microbalance with dissipation monitoring (QCM-D) technique in combination with video microscopy (VM) to obtain time-resolved information on the mass increase and rheological properties of evaporation-induced self-assembly of nanocubes. We have recorded the frequency and dissipation shifts during growth and densification of superlattices formed by self-assembly of oleic acid capped, truncated iron oxide nanocubes and analyzed the time-resolved QCM-D data using a Kelvin-Voigt viscoelastic model. We show that the nanoparticles first assemble into solvent-containing arrays dominated by a viscous response followed by a solvent-releasing step that results in the formation of rigid and well-ordered superlattices. Our findings demonstrate that QCM-D can be successfully used to follow self-assembly and assist in the design of optimized routes to produce well-ordered superlattices. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
The relative importance of fluid and kinetic frequency shifts of an electron plasma wave
NASA Astrophysics Data System (ADS)
Winjum, B. J.; Fahlen, J.; Mori, W. B.
2007-10-01
The total nonlinear frequency shift of a plasma wave including both fluid and kinetic effects is estimated when the phase velocity of the wave is much less than the speed of light. Using a waterbag or fluid model, the nonlinear frequency shift due to harmonic generation is calculated for an arbitrary shift in the wavenumber. In the limit where the wavenumber does not shift, the result is in agreement with previously published work [R. L. Dewar and J. Lindl, Phys. Fluids 15, 820 (1972); T. P. Coffey, Phys. Fluids 14, 1402 (1971)]. This shift is compared to the kinetic shift of Morales and O'Neil [G. J. Morales and T. M. O'Neil, Phys. Rev. Lett. 28, 417 (1972)] for wave amplitudes and values of kλD of interest to Raman backscatter of a laser driver in inertial confinement fusion.
On-field measurement trial of 4×128 Gbps PDM-QPSK signals by linear optical sampling
NASA Astrophysics Data System (ADS)
Bin Liu; Wu, Zhichao; Fu, Songnian; Feng, Yonghua; Liu, Deming
2017-02-01
Linear optical sampling is a promising characterization technique for advanced modulation formats, together with digital signal processing (DSP) and software-synchronized algorithm. We theoretically investigate the acquisition of optical sampling, when the high-speed signal under test is either periodic or random. Especially, when the profile of optical sampling pulse is asymmetrical, the repetition frequency of sampling pulse needs careful adjustment in order to obtain correct waveform. Then, we demonstrate on-field measurement trial of commercial four-channel 128 Gbps polarization division multiplexing quadrature phase shift keying (PDM-QPSK) signals with truly random characteristics by self-developed equipment. A passively mode-locked fiber laser (PMFL) with a repetition frequency of 95.984 MHz is used as optical sampling source, meanwhile four balanced photo detectors (BPDs) with 400 MHz bandwidth and four-channel analog-to-digital convertor (ADC) with 1.25 GS/s sampling rate are used for data acquisition. The performance comparison with conventional optical modulation analyzer (OMA) verifies that the self-developed equipment has the advantages of low cost, easy implementation, and fast response.
Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting
Yun, S. H.; Tearney, G. J.; de Boer, J. F.; Bouma, B. E.
2009-01-01
A novel technique using an acousto-optic frequency shifter in optical frequency domain imaging (OFDI) is presented. The frequency shift eliminates the ambiguity between positive and negative differential delays, effectively doubling the interferometric ranging depth while avoiding image cross-talk. A signal processing algorithm is demonstrated to accommodate nonlinearity in the tuning slope of the wavelength-swept OFDI laser source. PMID:19484034
Yao, Zhongqi; Luo, Jie; Lai, Yun
2017-12-11
In this work, we propose that one-dimensional ultratransparent dielectric photonic crystals with wide-angle impedance matching and shifted elliptical equal frequency contours are promising candidate materials for illusion optics. The shift of the equal frequency contour does not affect the refractive behaviors, but enables a new degree of freedom in phase modulation. With such ultratransparent photonic crystals, we demonstrate some applications in illusion optics, including creating illusions of a different-sized scatterer and a shifted source with opposite phase. Such ultratransparent dielectric photonic crystals may establish a feasible platform for illusion optics devices at optical frequencies.
Sudo, S; Ohtomo, T; Otsuka, K
2015-08-01
We achieved a highly sensitive method for observing the motion of colloidal particles in a flowing suspension using a self-mixing laser Doppler velocimeter (LDV) comprising a laser-diode-pumped thin-slice solid-state laser and a simple photodiode. We describe the measurement method and the optical system of the self-mixing LDV for real-time measurements of the motion of colloidal particles. For a condensed solution, when the light scattered from the particles is reinjected into the solid-state laser, the laser output is modulated in intensity by the reinjected laser light. Thus, we can capture the motion of colloidal particles from the spectrum of the modulated laser output. For a diluted solution, when the relaxation oscillation frequency coincides with the Doppler shift frequency, fd, which is related to the average velocity of the particles, the spectrum reflecting the motion of the colloidal particles is enhanced by the resonant excitation of relaxation oscillations. Then, the spectral peak reflecting the motion of colloidal particles appears at 2×fd. The spectrum reflecting the motion of colloidal particles in a flowing diluted solution can be measured with high sensitivity, owing to the enhancement of the spectrum by the thin-slice solid-state laser.
Frequency-Modulation Correlation Spectrometer
NASA Technical Reports Server (NTRS)
Margolis, J. S.; Martonchik, J. V.
1985-01-01
New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.
Petito Boyce, Catherine; Sax, Sonja N; Cohen, Joel M
2017-08-01
Inhalation plays an important role in exposures to lead in airborne particulate matter in occupational settings, and particle size determines where and how much of airborne lead is deposited in the respiratory tract and how much is subsequently absorbed into the body. Although some occupational airborne lead particle size data have been published, limited information is available reflecting current workplace conditions in the U.S. To address this data gap, the Battery Council International (BCI) conducted workplace monitoring studies at nine lead acid battery manufacturing facilities (BMFs) and five secondary smelter facilities (SSFs) across the U.S. This article presents the results of the BCI studies focusing on the particle size distributions calculated from Personal Marple Impactor sampling data and particle deposition estimates in each of the three major respiratory tract regions derived using the Multiple-Path Particle Dosimetry model. The BCI data showed the presence of predominantly larger-sized particles in the work environments evaluated, with average mass median aerodynamic diameters (MMADs) ranging from 21-32 µm for the three BMF job categories and from 15-25 µm for the five SSF job categories tested. The BCI data also indicated that the percentage of lead mass measured at the sampled facilities in the submicron range (i.e., <1 µm, a particle size range associated with enhanced absorption of associated lead) was generally small. The estimated average percentages of lead mass in the submicron range for the tested job categories ranged from 0.8-3.3% at the BMFs and from 0.44-6.1% at the SSFs. Variability was observed in the particle size distributions across job categories and facilities, and sensitivity analyses were conducted to explore this variability. The BCI results were compared with results reported in the scientific literature. Screening-level analyses were also conducted to explore the overall degree of lead absorption potentially associated with the observed particle size distributions and to identify key issues associated with applying such data to set occupational exposure limits for lead.
Changes in social roles as predictors of changes in drinking behaviour.
Hajema, K J; Knibbe, R A
1998-11-01
To assess the possible effects of changes in marital status, employment status and having children at home on alcohol consumption and the frequency of heavy drinking. With role theory as a starting point it was expected that a shift into more social roles would decrease consumption and heavy drinking while the shift away from social roles would be associated with an increase in consumption and heavy drinking. Prospective cohort study. The province of Limburg, The Netherlands (1980-89). 1327 men and women aged 16-69 years at first measurement. Weekly consumption of standard units (10 g ethanol) of alcoholic beverages; frequency of drinking six units or more; self-reported social role. The acquisition of a spouse role and a parental role but not an employment role was associated with a decrease in consumption or heavy drinking. The loss of the spouse role among women was associated with an increase in heavy drinking. Otherwise, losing a role was not linked with a change in consumption and heavy drinking. Limited support was found for the expectation that role transitions influence drinking behaviour. Our study suggests that other theories must be sought to explain social differences in drinking behaviour.
NASA Astrophysics Data System (ADS)
Kakue, T.; Endo, Y.; Shimobaba, T.; Ito, T.
2014-11-01
We report frequency estimation of loudspeaker diaphragm vibrating at high speed by parallel phase-shifting digital holography which is a technique of single-shot phase-shifting interferometry. This technique records multiple phaseshifted holograms required for phase-shifting interferometry by using space-division multiplexing. We constructed a parallel phase-shifting digital holography system consisting of a high-speed polarization-imaging camera. This camera has a micro-polarizer array which selects four linear polarization axes for 2 × 2 pixels. We set a loudspeaker as an object, and recorded vibration of diaphragm of the loudspeaker by the constructed system. By the constructed system, we demonstrated observation of vibration displacement of loudspeaker diaphragm. In this paper, we aim to estimate vibration frequency of the loudspeaker diaphragm by applying the experimental results to frequency analysis. Holograms consisting of 128 × 128 pixels were recorded at a frame rate of 262,500 frames per second by the camera. A sinusoidal wave was input to the loudspeaker via a phone connector. We observed displacement of the loudspeaker diaphragm vibrating by the system. We also succeeded in estimating vibration frequency of the loudspeaker diaphragm by applying frequency analysis to the experimental results.
Atomic Clocks with Suppressed Blackbody Radiation Shift
NASA Astrophysics Data System (ADS)
Yudin, V. I.; Taichenachev, A. V.; Okhapkin, M. V.; Bagayev, S. N.; Tamm, Chr.; Peik, E.; Huntemann, N.; Mehlstäubler, T. E.; Riehle, F.
2011-07-01
We develop a concept of atomic clocks where the blackbody radiation shift and its fluctuations can be suppressed by 1-3 orders of magnitude independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies ν1 and ν2) which are exposed to the same thermal environment, there exists a “synthetic” frequency νsyn ∝ (ν1-ɛ12ν2) largely immune to the blackbody radiation shift. For example, in the case of Yb+171 it is possible to create a synthetic-frequency-based clock in which the fractional blackbody radiation shift can be suppressed to the level of 10-18 in a broad interval near room temperature (300±15K). We also propose a realization of our method with the use of an optical frequency comb generator stabilized to both frequencies ν1 and ν2, where the frequency νsyn is generated as one of the components of the comb spectrum.
Mass defect effects in atomic clocks
NASA Astrophysics Data System (ADS)
Yudin, Valeriy; Taichenachev, Alexey
2018-03-01
We consider some implications of the mass defect on the frequency of atomic transitions. We have found that some well-known frequency shifts (the gravitational shift and motion-induced shifts such as quadratic Doppler and micromotion shifts) can be interpreted as consequences of the mass defect in quantum atomic physics, i.e. without the need for the concept of time dilation used in special and general relativity theories. Moreover, we show that the inclusion of the mass defect leads to previously unknown shifts for clocks based on trapped ions.
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
NASA Astrophysics Data System (ADS)
Brown, R. C.; Phillips, N. B.; Beloy, K.; McGrew, W. F.; Schioppo, M.; Fasano, R. J.; Milani, G.; Zhang, X.; Hinkley, N.; Leopardi, H.; Yoon, T. H.; Nicolodi, D.; Fortier, T. M.; Ludlow, A. D.
2017-12-01
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an 171Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10-18 level and beyond.
NASA Technical Reports Server (NTRS)
Bahadur, H.; Parshad, R.
1981-01-01
The frequency behavior of AT-cut quartz crystals irradiated by X -, gamma rays and fast neutrons. Initial instability in frequency for gamma and neutron irradiated crystals was found. All the different radiations first give a negative frequency shift at lower doses which are followed by positive frequency shift for increased doses. Results are explained in terms of the fundamental crystal structure. Applications of the frequency results for radiation hardening are proposed.
Reversal of orbital angular momentum arising from an extreme Doppler shift
Toninelli, Ermes; Horsley, Simon A. R.; Hendry, Euan; Phillips, David B.; Padgett, Miles J.
2018-01-01
The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes “negative.” In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at ≈100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the “negative frequency” regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. PMID:29581257
Frequency shifts in distortion-product otoacoustic emissions evoked by swept tones
Shera, Christopher A.; Abdala, Carolina
2016-01-01
When distortion-product otoacoustic emissions (DPOAEs) are evoked using stimuli whose instantaneous frequencies change rapidly and continuously with time (swept tones), the oscillatory interference pattern known as distortion-product fine structure shifts slightly along the frequency axis in the same direction as the sweep. By analogy with the temporal mechanisms thought to underlie the differing efficacies of up- and down-swept stimuli as perceptual maskers (e.g., Schroeder-phase complexes), fine-structure shifts have been ascribed to the phase distortion associated with dispersive wave propagation in the cochlea. This paper tests an alternative hypothesis and finds that the observed shifts arise predominantly as a methodological side effect of the analysis procedures commonly used to extract delayed emissions from the measured time waveform. Approximate expressions for the frequency shifts of DPOAE distortion and reflection components are derived, validated with computer simulations, and applied to account for DPOAE fine-structure shifts measured in human subjects. Component magnitudes are shown to shift twice as much as component phases. Procedures for compensating swept-tone measurements to obtain estimates of the total DPOAE and its components measured at other sweep rates or in the sinusoidal steady state are presented. PMID:27586726
NASA Astrophysics Data System (ADS)
Lider, M. C.; Yurtseven, H.
2018-05-01
The resonant frequency shifts are related to the thermodynamic quantities (compressibility, order parameter and susceptibility) for the α-β transition in quartz. The experimental data for the resonant frequencies and the bulk modulus from the literature are used for those correlations. By calculating the order parameter from the mean field theory, correlation between the resonant frequencies of various modes and the order parameter is examined according to the quasi-harmonic phonon theory for the α-β transition in quartz. Also, correlation between the bulk modulus in relation to the resonant frequency shifts and the order parameter susceptibility is constructed for the α-β transition in this crystalline system.
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2014 CFR
2014-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
47 CFR 97.307 - Emission standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-modulated emission may have a modulation index greater than 1 at the highest modulation frequency. (2) No..., or for frequency-shift keying, the frequency shift between mark and space must not exceed 1 kHz. (5... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO...
The detection of brain oedema with frequency-dependent phase shift electromagnetic induction.
González, César A; Rubinsky, Boris
2006-06-01
The spectroscopic distribution of inductive phase shift in the brain as a function of the relative volume of oedema was evaluated with theoretical and experimental methods in the frequency range 1 to 8 MHz. The theoretical study employed a simple mathematical model of electromagnetic induction in tissue and brain tissue data available from the literature to calculate the phase shift as a function of oedema in the bulk of the brain. Experimental data were generated from bulk measurements of ex vivo homogenized pig brain tissue mixed with various volumes of physiological saline in a volume sample typical of the human brain. There is good agreement between the analytical and the experimental results. Detectable changes in phase shift begin from a frequency of about 3 MHz to 4 MHz in the tested compositions and volume. The phase shift increases with frequency and fluid content. The results suggest that measuring phase shift in the bulk of the brain has the potential for becoming a robust means for non-contact detection of oedema in the brain.
Yüce, Emre; Ctistis, Georgios; Claudon, Julien; Gérard, Jean-Michel; Vos, Willem L
2016-01-11
We have switched GaAs/AlAs and AlGaAs/AlAs planar microcavities that operate in the "Original" (O) telecom band by exploiting the instantaneous electronic Kerr effect. We observe that the resonance frequency reversibly shifts within one picosecond when the nanostructure is pumped with low-energy photons. We investigate experimentally and theoretically the role of several parameters: the material backbone and its electronic bandgap, the quality factor, and the duration of the switch pulse. The magnitude of the frequency shift is reduced when the backbone of the central λ-layer has a greater electronic bandgap compared to the cavity resonance frequency and the frequency of the pump. This observation is caused by the fact that pumping with photon energies near the bandgap resonantly enhances the switched magnitude. We thus find that cavities operating in the telecom O-band are more amenable to ultrafast Kerr switching than those operating at lower frequencies, such as the C-band. Our results indicate that the large bandgap of AlGaAs/AlAs cavity allows to tune both the pump and the probe to the telecom range to perform Kerr switching without detrimental two-photon absorption. We observe that the magnitude of the resonance frequency shift decreases with increasing quality factor of the cavity. Our model shows that the magnitude of the resonance frequency shift depends on the pump pulse duration and is maximized when the duration matches the cavity storage time to within a factor two. In our experiments, we obtain a maximum shift of the cavity resonance relative to the cavity linewidth of 20%. We project that the shift of the cavity resonance can be increased twofold with a pump pulse duration that better matches the cavity storage time. We provide the essential parameter settings for different materials so that the frequency shift of the cavity resonance can be maximized using the electronic Kerr effect.
Bloch-Siegert shift in an interacting Bose-Einstein condensate
NASA Astrophysics Data System (ADS)
Zhang, Jinyi; Eigen, Christoph; Lopes, Raphael; Garratt, Sam; Rousso, David; Smith, Robert P.; Hadzibabic, Zoran; Navon, Nir
2017-04-01
The Bloch-Siegert shift (BSS) is a paradigmatic frequency shift that arises from the nonlinear response of a two-level system (TLS) subjected to strong driving fields. When a TLS is driven by a linearly polarized field, the co-rotating-wave component leads to the famous Rabi oscillations. By contrast the co-rotating-wave component, whose role is usually neglected in a weak driving, leads to a frequency shift of the TLS resonance frequency. This phenomenon is encountered in various areas, from quantum optics to nuclear magnetic resonance.Here, we investigate the BSS in a box-trapped 87 Rb Bose-Einstein condensate (BEC) driven by a strong oscillating magnetic field gradient. By tuning the chemical potential of the gas, we investigate how the BSS evolves from the ideal shift of the two lowest energy levels of a single particle in a box to the unexplored shift of long-wavelength collective excitations of the interacting BEC.
Zander, Thorsten O.; Andreessen, Lena M.; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R.; Gramann, Klaus
2017-01-01
We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort. PMID:28293184
Zander, Thorsten O; Andreessen, Lena M; Berg, Angela; Bleuel, Maurice; Pawlitzki, Juliane; Zawallich, Lars; Krol, Laurens R; Gramann, Klaus
2017-01-01
We tested the applicability and signal quality of a 16 channel dry electroencephalography (EEG) system in a laboratory environment and in a car under controlled, realistic conditions. The aim of our investigation was an estimation how well a passive Brain-Computer Interface (pBCI) can work in an autonomous driving scenario. The evaluation considered speed and accuracy of self-applicability by an untrained person, quality of recorded EEG data, shifts of electrode positions on the head after driving-related movements, usability, and complexity of the system as such and wearing comfort over time. An experiment was conducted inside and outside of a stationary vehicle with running engine, air-conditioning, and muted radio. Signal quality was sufficient for standard EEG analysis in the time and frequency domain as well as for the use in pBCIs. While the influence of vehicle-induced interferences to data quality was insignificant, driving-related movements led to strong shifts in electrode positions. In general, the EEG system used allowed for a fast self-applicability of cap and electrodes. The assessed usability of the system was still acceptable while the wearing comfort decreased strongly over time due to friction and pressure to the head. From these results we conclude that the evaluated system should provide the essential requirements for an application in an autonomous driving context. Nevertheless, further refinement is suggested to reduce shifts of the system due to body movements and increase the headset's usability and wearing comfort.
Multiple-frequency continuous wave ultrasonic system for accurate distance measurement
NASA Astrophysics Data System (ADS)
Huang, C. F.; Young, M. S.; Li, Y. C.
1999-02-01
A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.
NASA Astrophysics Data System (ADS)
Bini, Donato; Damour, Thibault
2016-05-01
We consider Detweiler's redshift variable z for a nonspinning mass m1 in circular motion (with orbital frequency Ω ) around a nonspinning mass m2. We show how the combination of effective-one-body (EOB) theory with the first law of binary dynamics allows one to derive a simple, exact expression for the functional dependence of z on the (gauge-invariant) EOB gravitational potential u =(m1+m2)/R . We then use the recently obtained high-post-Newtonian(PN)-order knowledge of the main EOB radial potential A (u ;ν ) [where ν =m1m2/(m1+m2)2] to decompose the second-self-force-order contribution to the function z (m2Ω ,m1/m2) into a known part (which goes beyond the 4PN level in including the 5PN logarithmic term and the 5.5PN contribution) and an unknown one [depending on the yet unknown, 5PN, 6 PN ,… , contributions to the O (ν2) contribution to the EOB radial potential A (u ;ν )]. We apply our results to the second-self-force-order contribution to the frequency shift of the last stable orbit. We indicate the expected singular behaviors, near the lightring, of the second-self-force-order contributions to both the redshift and the EOB A potential. Our results should help both in extracting information of direct dynamical significance from ongoing second-self-force-order computations and in parametrizing their global strong-field behaviors. We also advocate computing second-self-force-order conservative quantities by iterating the time-symmetric Green-function in the background spacetime.
Spatial filtering velocimeter for vehicle navigation with extended measurement range
NASA Astrophysics Data System (ADS)
He, Xin; Zhou, Jian; Nie, Xiaoming; Long, Xingwu
2015-05-01
The idea of using spatial filtering velocimeter is proposed to provide accurate velocity information for vehicle autonomous navigation system. The presented spatial filtering velocimeter is based on a CMOS linear image sensor. The limited frame rate restricts high speed measurement of the vehicle. To extend measurement range of the velocimeter, a method of frequency shifting is put forward. Theoretical analysis shows that the frequency of output signal can be reduced and the measurement range can be doubled by this method when the shifting direction is set the same with that of image velocity. The approach of fast Fourier transform (FFT) is employed to obtain the power spectra of the spatially filtered signals. Because of limited frequency resolution of FFT, a frequency spectrum correction algorithm, called energy centrobaric correction, is used to improve the frequency resolution. The correction accuracy energy centrobaric correction is analyzed. Experiments are carried out to measure the moving surface of a conveyor belt. The experimental results show that the maximum measurable velocity is about 800deg/s without frequency shifting, 1600deg/s with frequency shifting, when the frame rate of the image is about 8117 Hz. Therefore, the measurement range is doubled by the method of frequency shifting. Furthermore, experiments were carried out to measure the vehicle velocity simultaneously using both the designed SFV and a laser Doppler velocimeter (LDV). The measurement results of the presented SFV are coincident with that of the LDV, but with bigger fluctuation. Therefore, it has the potential of application to vehicular autonomous navigation.
Observation of an optical event horizon in a silicon-on-insulator photonic wire waveguide.
Ciret, Charles; Leo, François; Kuyken, Bart; Roelkens, Gunther; Gorza, Simon-Pierre
2016-01-11
We report on the first experimental observation of an optical analogue of an event horizon in integrated nanophotonic waveguides, through the reflection of a continuous wave on an intense pulse. The experiment is performed in a dispersion-engineered silicon-on-insulator waveguide. In this medium, solitons do not suffer from Raman induced self-frequency shift as in silica fibers, a feature that is interesting for potential applications of optical event horizons. As shown by simulations, this also allows the observation of multiple reflections at the same time on fundamental solitons ejected by soliton fission.
All-optical control of group velocity dispersion in tellurite photonic crystal fibers.
Liu, Lai; Tian, Qijun; Liao, Meisong; Zhao, Dan; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping
2012-12-15
We demonstrate all-optical control of group velocity dispersion (GVD) via optical Kerr effect in highly nonlinear tellurite photonic crystal fibers. The redshift of the zero-dispersion wavelength is over 307 nm, measured by soliton self-frequency shift cancellation, when the pump peak power of a 1.56 μm femtosecond fiber laser is increased to 11.6 kW. The all-optical control of GVD not only offers a new platform for constructing all-optical-control photonic devices but also promises a new class of experiments in nonlinear fiber optics and light-matter interactions.
Constant frequency pulsed phase-locked loop measuring device
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Kushnick, Peter W. (Inventor); Cantrell, John H. (Inventor)
1993-01-01
A measuring apparatus is presented that uses a fixed frequency oscillator to measure small changes in the phase velocity ultrasonic sound when a sample is exposed to environmental changes such as changes in pressure, temperature, etc. The invention automatically balances electrical phase shifts against the acoustical phase shifts in order to obtain an accurate measurement of electrical phase shifts.
NASA Astrophysics Data System (ADS)
Wang, Jiabao; Wen, Zhiping; Wu, Renguang; Guo, Yuanyuan; Chen, Zesheng
2016-06-01
The East Asia-Pacific (EAP) pattern is a well-known meridional teleconnection over East Asia during boreal summer. In this study, the mechanism for growth of the EAP on intraseasonal timescale is investigated through a vorticity budget. It is found that the beta-effect and high-frequency transient eddies have primary contributions to the growth of the low-frequency EAP. The former leads to a westward shift of disturbances associated with the low-frequency EAP and the latter favors an amplification of disturbances, respectively. The interaction between low-frequency disturbances and zonal flow has a damping effect by dragging disturbances eastward. The impact of boreal summer intraseasonal oscillation (BSISO) on the triggering of the low-frequency EAP is also examined in this study based on observational analysis and a linear model experiment. It is shown that an elongated anomalous convection band located in the vicinity of Philippines associated with the dominant mode of BSISO has a significant impact on the initiation of low-frequency EAP via Rossby wave propagation, whereas anomalous convection located over the North Indian Ocean has a limited impact. Based on the results of present study, the low-frequency EAP could be a self-sustained mode, and the BSISO plays a substantial role in triggering the low-frequency EAP.
Heart-rate variability and precompetitive anxiety in swimmers.
Cervantes Blásquez, Julio César; Rodas Font, Gil; Capdevila Ortís, Lluís
2009-11-01
The aim of this study was to test the utility of heart-rate variability (HRV) analyses as a noninvasive means of quantifying cardiac autonomic regulation during precompetitive anxiety situations in swimmers. Psychophysiological state evaluation of 10 volunteer
Driven acoustic oscillations within a vertical magnetic field
NASA Technical Reports Server (NTRS)
Hindman, Bradley W.; Zweibel, Ellen G.; Cally, P. S.
1995-01-01
The effects of a vertical magnetic field on p-mode frequencies, line widths, and eigenfunctions, are examined. A solar model, consisting of a neutrally stable polytropic interior matched to an isothermal chromosphere, is applied. The p-modes are produced by a spatially distributed driver. The atmosphere is threaded by a constant vertical magnetic field. The frequency shifts due to the vertical magnetic field are found to be much smaller than the shifts caused by horizontal fields of similar strength. A large vertical field of 2000 G produces shifts of several nHz. It is found that the frequency shifts decrease with increasing frequency and increase with field strength. The coupling of the acoustic fast mode to the escaping slow modes is inefficient. Constant vertical magnetic field models are therefore incapable of explaining the high level of absorption observed in sunspots and plage.
Attenuation analysis of real GPR wavelets: The equivalent amplitude spectrum (EAS)
NASA Astrophysics Data System (ADS)
Economou, Nikos; Kritikakis, George
2016-03-01
Absorption of a Ground Penetrating Radar (GPR) pulse is a frequency dependent attenuation mechanism which causes a spectral shift on the dominant frequency of GPR data. Both energy variation of GPR amplitude spectrum and spectral shift were used for the estimation of Quality Factor (Q*) and subsequently the characterization of the subsurface material properties. The variation of the amplitude spectrum energy has been studied by Spectral Ratio (SR) method and the frequency shift by the estimation of the Frequency Centroid Shift (FCS) or the Frequency Peak Shift (FPS) methods. The FPS method is more automatic, less robust. This work aims to increase the robustness of the FPS method by fitting a part of the amplitude spectrum of GPR data with Ricker, Gaussian, Sigmoid-Gaussian or Ricker-Gaussian functions. These functions fit different parts of the spectrum of a GPR reference wavelet and the Equivalent Amplitude Spectrum (EAS) is selected, reproducing Q* values used in forward Q* modeling analysis. Then, only the peak frequencies and the time differences between the reference wavelet and the subsequent reflected wavelets are used to estimate Q*. As long as the EAS is estimated, it is used for Q* evaluation in all the GPR section, under the assumption that the selected reference wavelet is representative. De-phasing and constant phase shift, for obtaining symmetrical wavelets, proved useful in the sufficiency of the horizons picking. Synthetic, experimental and real GPR data were examined in order to demonstrate the effectiveness of the proposed methodology.
Karhula, Kati; Härmä, Mikko; Ropponen, Annina; Hakola, Tarja; Sallinen, Mikael; Puttonen, Sampsa
2016-01-01
Twelve-hour shift systems have become more popular in industry. Survey data of shift length, shift rotation speed, self-rated sleep, satisfaction and perceived health were investigated for the associations among 599 predominantly male Finnish industrial employees. The studied forward-rotating shift systems were 12-h fast (12fast, DDNN------, n = 268), 8-h fast (8fast, MMEENN----, n = 161) and 8-h slow (8slow, MMMM-EEEE-NNNN, n = 170). Satisfaction with shift system differed between the groups (p < 0.01) after controlling for age, gender, shift work experience and self-rated stress. In the 12fast, 98% of employees were satisfied with their shift system (75% 8fast, 54% 8slow). Negative effects on sleep and alertness were rare (8%) in the 12fast group (53% 8fast, 66% 8 slow, p < 0.01) and self-reported sleep difficulties were less frequent than in the 8fast and 8slow groups (8%, 27%, 41%, respectively, p < 0.01). The self-reported average sleep duration (12fast 7:50, 8fast 7:24, 8slow 7:15, p < 0.01), and shift-specific sleep before and between morning shifts and after first night shift were longer in the 12fast group. Perceived negative effects of the current shift system on general health (12fast 4%, 8fast 30%, 8slow 41%, p < 0.001) and work-life balance (12fast 8%, 8fast 52%, 8slow 63%, p < 0.001) differed strongly between the groups. In conclusion, the perceived effects of shift work were dependent on both shift length and shift rotation speed: employees in the 12-h rapidly forward-rotating shift system were most satisfied, perceived better work-life balance and slept better than the employees in the 8fast or especially the employees in the 8-h slowly rotating systems.
Roles of safety climate and shift work on perceived injury risk: a multi-level analysis.
Huang, Yueng-Hsiang; Chen, Jiu-Chiuan; DeArmond, Sarah; Cigularov, Konstantin; Chen, Peter Y
2007-11-01
This study evaluated the relationship between employees' work shift (i.e., day shift versus night shift) and perceptions of injury risk, and how the relationship is affected by company level safety climate and injury frequency. The results showed that night shift workers perceived a higher level of injury risk compared to day shift workers. Both company level safety climate and injury frequency played critical roles in predicting individual perceived work injury risk. Perception of injury risk of night shift workers was significantly lower when they perceived high-level rather than low-level safety climate. However, this pattern was not noticeable for day shift workers. These findings highlighted the importance of considering company level factors when attempting to understand the differences between day shift and night shift work on an individual's perception of injury risk.
Frequency-Shift Detectors Bind Binaural as Well as Monaural Frequency Representations
ERIC Educational Resources Information Center
Carcagno, Samuele; Semal, Catherine; Demany, Laurent
2011-01-01
Previous psychophysical work provided evidence for the existence of automatic frequency-shift detectors (FSDs) that establish perceptual links between successive sounds. In this study, we investigated the characteristics of the FSDs with respect to the binaural system. Listeners were presented with sound sequences consisting of a chord of pure…
Rapid jamming avoidance in biosonar.
Gillam, Erin H; Ulanovsky, Nachum; McCracken, Gary F
2007-03-07
The sonar systems of bats and dolphins are in many ways superior to man-made sonar and radar systems, and considerable effort has been devoted to understanding the signal-processing strategies underlying these capabilities. A major feature determining the efficiency of sonar systems is the sensitivity to noise and jamming signals. Previous studies indicated that echolocating bats may adjust their signal structure to avoid jamming ('jamming avoidance response'; JAR). However, these studies relied on behavioural correlations and not controlled experiments. Here, we provide the first experimental evidence for JAR in bats. We presented bats (Tadarida brasiliensis) with 'playback stimuli' consisting of recorded echolocation calls at one of six frequencies. The bats exhibited a JAR by shifting their call frequency away from the presented playback frequency. When the approaching bats were challenged by an abrupt change in the playback stimulus, they responded by shifting their call frequencies upwards, away from the playback. Interestingly, even bats initially calling below the playback's frequency shifted their frequencies upwards, 'jumping' over the playback frequency. These spectral shifts in the bats' calls occurred often within less than 200 ms, in the first echolocation call emitted after the stimulus switch-suggesting that rapid jamming avoidance is important for the bat.
Taylor, P. J.
1967-01-01
Despite the increasing use of continuous process shift work in modern industry, few studies on the medical aspects of shift work can be found in recent literature of occupational health. Physiologists have shown that the ability of the body to adjust its circadian rhythms to alteration in hours of work or sleep can take up to a month. The usual type of shift work in industry involves weekly changes of hours, and thus on theoretical grounds at least this may not be the most suitable frequency for shift changes. Sickness absence of male refinery workers has been studied over a four-year period. The figures show that continuous three-cycle shift workers have consistently and significantly lower rates of sickness than day workers in similar occupations. The annual inception rate (spells) standardized for age was 108% for shift workers and 182% for day workers, and the average annual duration per man was 11 days for shift workers and 18 days for day workers, although the average length of spell was slightly longer among shift workers. As far as is known, such a difference has not been described before in detail. Age-related lateness and absenteeism have been measured and show similar wide differences between the two groups. Although both types of worker are largely self-selected, the difference is not due to medical selection or to an excess of any one type of disease in day workers. Over three-quarters of 150 shift workers interviewed stated that they preferred shift work hours and that sleeping difficulties were not common. It is suggested that the main reasons for the difference between shift and day workers' sickness absence lie in the degree of personal involvement in the work and in the social structure of the working group. PMID:6023084
From self-organization to emergence: Aesthetic implications of shifting ideas of organization
NASA Astrophysics Data System (ADS)
Hayles, N. Katherine
1996-06-01
From 1945-95, a shift took place within cybernetics from a paradigm emphasizing self-organization to one emphasizing emergence. Central in bringing about this shift was the spread of the microcomputer. With its greatly enhanced processing speed and memory capabilities, the microcomputer made simulations possible that could not have been done before. The microcomputer has also been instrumental in effecting a similar change within literary texts. To exemplify the aesthetic implications of the shift from self-organization to emergence, the chapter discusses Vladmir Nabokov's Pale Fire and Milorad Pavić's Dictionary of the Khazars: A Lexicon Novel in 100,000 Words.
Development of high precision digital driver of acoustic-optical frequency shifter for ROG
NASA Astrophysics Data System (ADS)
Zhang, Rong; Kong, Mei; Xu, Yameng
2016-10-01
We develop a high precision digital driver of the acoustic-optical frequency shifter (AOFS) based on the parallel direct digital synthesizer (DDS) technology. We use an atomic clock as the phase-locked loop (PLL) reference clock, and the PLL is realized by a dual digital phase-locked loop. A DDS sampling clock up to 320 MHz with a frequency stability as low as 10-12 Hz is obtained. By constructing the RF signal measurement system, it is measured that the frequency output range of the AOFS-driver is 52-58 MHz, the center frequency of the band-pass filter is 55 MHz, the ripple in the band is less than 1 dB@3MHz, the single channel output power is up to 0.3 W, the frequency stability is 1 ppb (1 hour duration), and the frequency-shift precision is 0.1 Hz. The obtained frequency stability has two orders of improvement compared to that of the analog AOFS-drivers. For the designed binary frequency shift keying (2-FSK) and binary phase shift keying (2-PSK) modulation system, the demodulating frequency of the input TTL synchronous level signal is up to 10 kHz. The designed digital-bus coding/decoding system is compatible with many conventional digital bus protocols. It can interface with the ROG signal detecting software through the integrated drive electronics (IDE) and exchange data with the two DDS frequency-shift channels through the signal detecting software.
Connecting self-efficacy and views about the nature of science in undergraduate research experiences
NASA Astrophysics Data System (ADS)
Quan, Gina M.; Elby, Andrew
2016-12-01
Undergraduate research can support students' more central participation in physics. We analyze markers of two coupled shifts in participation: changes in students' views about the nature of science coupled to shifts in self-efficacy toward physics research. Students in the study worked with faculty and graduate student mentors on research projects while also participating in a seminar where they learned about research and reflected on their experiences. In classroom discussions and in clinical interviews, students described gaining more nuanced views about the nature of science, specifically related to who can participate in research and what participation in research looks like. This shift was coupled to gains in self-efficacy toward their ability to contribute to research; they felt like their contributions as novices mattered. We present two case studies of students who experienced coupled shifts in self-efficacy and views about nature-of-science shifts, and a case study of a student for whom we did not see either shift, to illustrate both the existence of the coupling and the different ways it can play out. After making the case that this coupling occurs, we discuss some potential underlying mechanisms. Finally, we use these results to argue for more nuanced interpretations of self-efficacy measurements.
Amplitude-frequency effect of Y-cut langanite and langatate.
Kim, Yoonkee
2003-12-01
Amplitude-frequency effect of a Y-cut langanite (LGN) resonator and a Y-cut langatate (LGT) resonator were measured. The frequency shifts from the baseline frequency with 1 mA were measured as a function of drive currents up to 28 mA. High-drive current shifted the frequency, but it also heated the crystal locally, causing temperature-related frequency changes. The local heat transfer and its influence on the frequency were analyzed. The amplitude-frequency shift was effectively measured, and was not affected by the temperature-related frequency changes. The 3rd, 5th, and 7th overtones (OT's) were found to behave as soft springs, i.e., resonant frequency decreases as drive current increases. The drive sensitivity coefficients of the 3rd and 5th OT's are in the vicinity of -2 ppb/mA2 for both resonators. The 7th OT's are higher than the other OT's: -5 approximately -7 ppb/mA2. The lowest drive sensitivity is -1.2 ppb/mA2 on the 5th OT of the LGT.
NASA Astrophysics Data System (ADS)
Hefferman, Gerald; Chen, Zhen; Wei, Tao
2017-07-01
This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.
Hefferman, Gerald; Chen, Zhen; Wei, Tao
2017-07-01
This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.
Cunningham, Charles H; Dominguez Viqueira, William; Hurd, Ralph E; Chen, Albert P
2014-02-01
Blip-reversed echo-planar imaging (EPI) is investigated as a method for measuring and correcting the spatial shifts that occur due to bulk frequency offsets in (13)C metabolic imaging in vivo. By reversing the k-space trajectory for every other time point, the direction of the spatial shift for a given frequency is reversed. Here, mutual information is used to find the 'best' alignment between images and thereby measure the frequency offset. Time-resolved 3D images of pyruvate/lactate/urea were acquired with 5 s temporal resolution over a 1 min duration in rats (N = 6). For each rat, a second injection was performed with the demodulation frequency purposely mis-set by +35 Hz, to test the correction for erroneous shifts in the images. Overall, the shift induced by the 35 Hz frequency offset was 5.9 ± 0.6 mm (mean ± standard deviation). This agrees well with the expected 5.7 mm shift based on the 2.02 ms delay between k-space lines (giving 30.9 Hz per pixel). The 0.6 mm standard deviation in the correction corresponds to a frequency-detection accuracy of 4 Hz. A method was presented for ensuring the spatial registration between (13)C metabolic images and conventional anatomical images when long echo-planar readouts are used. The frequency correction method was shown to have an accuracy of 4 Hz. Summing the spatially corrected frames gave a signal-to-noise ratio (SNR) improvement factor of 2 or greater, compared with the highest single frame. Copyright © 2013 John Wiley & Sons, Ltd.
Improvement in Rayleigh Scattering Measurement Accuracy
NASA Technical Reports Server (NTRS)
Fagan, Amy F.; Clem, Michelle M.; Elam, Kristie A.
2012-01-01
Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.
Apparatus and method for noninvasive particle detection using doppler spectroscopy
Sinha, Dipen N.
2016-05-31
An apparatus and method for noninvasively detecting the presence of solid particulate matter suspended in a fluid flowing through a pipe or an oil and gas wellbore are described. Fluid flowing through a conduit containing the particulate solids is exposed to a fixed frequency (>1 MHz) of ultrasonic vibrations from a transducer attached to the outside of the pipe. The returning Doppler frequency shifted signal derived from the scattering of sound from the moving solid particles is detected by an adjacent transducer. The transmitted signal and the Doppler signal are combined to provide sensitive particulate detection. The magnitude of the signal and the Doppler frequency shift are used to determine the particle size distribution and the velocity of the particles. Measurement of the phase shift between the applied frequency and the detected Doppler shifted may be used to determine the direction of motion of the particles.
On the Coriolis effect in acoustic waveguides.
Wegert, Henry; Reindl, Leonard M; Ruile, Werner; Mayer, Andreas P
2012-05-01
Rotation of an elastic medium gives rise to a shift of frequency of its acoustic modes, i.e., the time-period vibrations that exist in it. This frequency shift is investigated by applying perturbation theory in the regime of small ratios of the rotation velocity and the frequency of the acoustic mode. In an expansion of the relative frequency shift in powers of this ratio, upper bounds are derived for the first-order and the second-order terms. The derivation of the theoretical upper bounds of the first-order term is presented for linear vibration modes as well as for stable nonlinear vibrations with periodic time dependence that can be represented by a Fourier series.
NASA Technical Reports Server (NTRS)
Poulain, Pierre-Marie; Luther, Douglas S.; Patzert, William C.
1992-01-01
Two techniques were developed for estimating statistics of inertial oscillations from satellite-tracked drifters that overcome the difficulties inherent in estimating such statistics from data dependent upon space coordinates that are a function of time. Application of these techniques to tropical surface drifter data collected during the NORPAX, EPOCS, and TOGA programs reveals a latitude-dependent, statistically significant 'blue shift' of inertial wave frequency. The latitudinal dependence of the blue shift is similar to predictions based on 'global' internal-wave spectral models, with a superposition of frequency shifting due to modification of the effective local inertial frequency by the presence of strongly sheared zonal mean currents within 12 deg of the equator.
Neural representations of the sense of self
Klemm, William R.
2011-01-01
The brain constructs representations of what is sensed and thought about in the form of nerve impulses that propagate in circuits and network assemblies (Circuit Impulse Patterns, CIPs). CIP representations of which humans are consciously aware occur in the context of a sense of self. Thus, research on mechanisms of consciousness might benefit from a focus on how a conscious sense of self is represented in brain. Like all senses, the sense of self must be contained in patterns of nerve impulses. Unlike the traditional senses that are registered by impulse flow in relatively simple, pauci-synaptic projection pathways, the sense of self is a system- level phenomenon that may be generated by impulse patterns in widely distributed complex and interacting circuits. The problem for researchers then is to identify the CIPs that are unique to conscious experience. Also likely to be of great relevance to constructing the representation of self are the coherence shifts in activity timing relations among the circuits. Consider that an embodied sense of self is generated and contained as unique combinatorial temporal patterns across multiple neurons in each circuit that contributes to constructing the sense of self. As with other kinds of CIPs, those representing the sense of self can be learned from experience, stored in memory, modified by subsequent experiences, and expressed in the form of decisions, choices, and commands. These CIPs are proposed here to be the actual physical basis for conscious thought and the sense of self. When active in wakefulness or dream states, the CIP representations of self act as an agent of the brain, metaphorically as an avatar. Because the selfhood CIP patterns may only have to represent the self and not directly represent the inner and outer worlds of embodied brain, the self representation should have more degrees of freedom than subconscious mind and may therefore have some capacity for a free-will mind of its own. S everal lines of evidence for this theory are reviewed. Suggested new research includes identifying distinct combinatorially coded impulse patterns and their temporal coherence shifts in defined circuitry, such as neocortical microcolumns. This task might be facilitated by identifying the micro-topography of field-potential oscillatory coherences among various regions and between different frequencies associated with specific conscious mentation. Other approaches can include identifying the changes in discrete conscious operations produced by focal trans-cranial magnetic stimulation. PMID:21826192
Su, Xiao-Li; Li, Yanbin
2004-01-15
A piezoelectric immunosensor was developed for rapid detection of Escherichia coli O157:H7. It was based on the immobilization of affinity-purified antibodies onto a monolayer of 16-mercaptohexadecanoic acid (MHDA), a long-chain carboxylic acid-terminating alkanethiol, self-assembled on an AT-cut quartz crystal's Au electrode surface with N-hydroxysuccinimide (NHS) ester as a reactive intermediate. The binding of target bacteria onto the immobilized antibodies decreased the sensor's resonant frequency, and the frequency shift was correlated to the bacterial concentration. The stepwise assembly of the immunosensor was characterized by means of both quartz crystal microbalance (QCM) and cyclic voltammetry techniques. Three analytical procedures, namely immersion, dip-and-dry and flow-through methods, were investigated. The immunosensor could detect the target bacteria in a range of 10(3)-10(8)CFU/ml within 30-50 min, and the sensor-to-sensor reproducibility obtained at 10(3) and 10(5) colony-forming units (CFU)/ml was 18 and 11% R.S.D., respectively. The proposed sensor was comparable to Protein A-based piezoelectric immunosensor in terms of the amount of immobilized antibodies and detection sensitivity.
NASA Astrophysics Data System (ADS)
Huang, S. S.; Huang, C. F.; Huang, K. N.; Young, M. S.
2002-10-01
A highly accurate binary frequency shift-keyed (BFSK) ultrasonic distance measurement system (UDMS) for use in isothermal air is described. This article presents an efficient algorithm which combines both the time-of-flight (TOF) method and the phase-shift method. The proposed method can obtain larger range measurement than the phase-shift method and also get higher accuracy compared with the TOF method. A single-chip microcomputer-based BFSK signal generator and phase detector was designed to record and compute the TOF, two phase shifts, and the resulting distance, which were then sent to either an LCD to display or a PC to calibrate. Experiments were done in air using BFSK with the frequencies of 40 and 41 kHz. Distance resolution of 0.05% of the wavelength corresponding to the frequency of 40 kHz was obtained. The range accuracy was found to be within ±0.05 mm at a range of over 6000 mm. The main advantages of this UDMS system are high resolution, low cost, narrow bandwidth requirement, and ease of implementation.
Elementary Pre-Service Teachers' Response-Shift Bias: Self-Efficacy and Attitudes toward Science
ERIC Educational Resources Information Center
Cartwright, Tina J.; Atwood, Jon
2014-01-01
Response-shift bias occurs when participants' initial constructs, such as self-efficacy in teaching science, are incomplete because they do not fully conceptualize something they have yet to experience. This study examines whether elementary pre-service teachers can consistently evaluate constructs such as self-efficacy and attitudes toward…
NASA Astrophysics Data System (ADS)
Yépez, L. D.; Carrillo, J. L.; Donado, F.; Sausedo-Solorio, J. M.; Miranda-Romagnoli, P.
2016-06-01
The dynamical pattern formation of clusters of magnetic particles in a low-concentration magnetorheological fluid, under the influence of a superposition of two perpendicular sinusoidal fields, is studied experimentally. By varying the frequency and phase shift of the perpendicular fields, this configuration enables us to experimentally analyze a wide range of field configurations, including the case of a pure rotating field and the case of an oscillating unidirectional field. The fields are applied parallel to the horizontal plane where the fluid lies or in the vertical plane. For fields applied in the horizontal plane, we observed that, when the ratio of the frequencies increases, the average cluster size exhibits a kind of periodic resonances. When the phase shift between the fields is varied, the average chain length reaches maximal values for the cases of the rotating field and the unidirectional case. We analyze and discuss these results in terms of a weighted average of the time-dependent Mason number. In the case of a rotating field on the vertical plane, we also observe that the competition between the magnetic and the viscous forces determines the average cluster size. We show that this configuration generates a series of physically meaningful self-organization of clusters and transport phenomena.
Karplus, H.H.B.; Raptis, A.C.
1981-11-13
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
Karplus, Henry H. B.; Raptis, Apostolos C.
1983-01-01
A Doppler flowmeter impulses an ultrasonic fixed-frequency signal obliquely into a slurry flowing in a pipe and a reflected signal is detected after having been scattered off of the slurry particles, whereby the shift in frequencies between the signals is proportional to the slurry velocity and hence slurry flow rate. This flowmeter filters the Doppler frequency-shift signal, compares the filtered and unfiltered shift signals in a divider to obtain a ratio, and then further compares this ratio against a preset fractional ratio. The flowmeter utilizes a voltage-to-frequency convertor to generate a pulsed signal having a determinable rate of repetition precisely proportional to the divergence of the ratios. The pulsed signal serves as the input control for a frequency-controlled low-pass filter, which provides thereby that the cutoff frequency of the filtered signal is known. The flowmeter provides a feedback control by minimizing the divergence. With the cutoff frequency and preset fractional ratio known, the slurry velocity and hence flow will also be determinable.
Digital phase shifter synchronizes local oscillators
NASA Technical Reports Server (NTRS)
Ali, S. M.
1978-01-01
Digital phase-shifting network is used as synchronous frequency multiplier for applications such as phase-locking two signals that may differ in frequency. Circuit has various phase-shift capability. Possible applications include data-communication systems and hybrid digital/analog phase-locked loops.
A binaural beat constructed from a noise
Akeroyd, Michael A
2012-01-01
The binaural beat has been used for over one hundred years as a stimulus for generating the percept of motion. Classically the beat consists of a pure tone at one ear (e.g. 500 Hz) and the same pure tone at the other ear but shifted upwards or downwards in frequency (e.g., 501 Hz). An experiment and binaural computational analysis are reported which demonstrate that a more powerful motion percept can be obtained by applying the concept of the frequency shift to a noise, via an upwards or downwards shift in the frequency of the Fourier components of its spectrum. PMID:21218863
Continuous wave operation of quantum cascade lasers with frequency-shifted feedback
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyakh, A., E-mail: arkadiy.lyakh@ucf.edu; NanoScience Technology Center, University of Central Florida, 12424 Research Pkwy, Orlando, FL 32826; College of Optics and Photonics, University of Central Florida, 304 Scorpius St, Orlando, FL 32826
2016-01-15
Operation of continuous wave quantum cascade lasers with a frequency-shifted feedback provided by an acousto-optic modulator is reported. Measured linewidth of 1.7 cm{sup −1} for these devices, under CW operating conditions, was in a good agreement with predictions of a model based on frequency-shifted feedback seeded by spontaneous emission. Linewidth broadening was observed for short sweep times, consistent with sound wave grating period variation across the illuminated area on the acousto-optic modulator. Standoff detection capability of the AOM-based QCL setup was demonstrated for several solid materials.
NASA Astrophysics Data System (ADS)
Refaeli, Zaharit; Shamir, Yariv; Ofir, Atara; Marcus, Gilad
2018-02-01
We report a simple robust and broadly spectral-adjustable source generating near fully compressed 1053 nm 62 fs pulses directly out of a highly-nonlinear photonic crystal fiber. A dispersion-nonlinearity balance of 800 nm Ti:Sa 20 fs pulses was obtained initially by negative pre-chirping and then launching the pulses into the fibers' normal dispersion regime. Following a self-phase modulation spectral broadening, some energy that leaked below the zero dispersion point formed a soliton whose central wavelength could be tuned by Self-Frequency-Raman-Shift effect. Contrary to a common approach of power, or, fiber-length control over the shift, here we continuously varied the state of polarization, exploiting the Raman and Kerr nonlinearities responsivity for state of polarization. We obtained soliton pulses with central wavelength tuned over 150 nm, spanning from well below 1000 to over 1150 nm, of which we could select stable pulses around the 1 μm vicinity. With linewidth of > 20 nm FWHM Gaussian-like temporal-shape pulses with 62 fs duration and near flat phase structure we confirmed high quality pulse source. We believe such scheme can be used for high energy or high power glass lasers systems, such as Nd or Yb ion-doped amplifiers and systems.
High-frequency tone burst-evoked ABR latency-intensity functions.
Fausti, S A; Olson, D J; Frey, R H; Henry, J A; Schaffer, H I
1993-01-01
High-frequency tone burst stimuli (8, 10, 12, and 14 kHz) have been developed and demonstrated to provide reliable and valid auditory brainstem responses (ABRs) in normal-hearing subjects. In this study, latency-intensity functions (LIFs) were determined using these stimuli in 14 normal-hearing individuals. Significant shifts in response latency occurred as a function of stimulus intensity for all tone burst frequencies. For each 10 dB shift in intensity, latency shifts for waves I and V were statistically significant except for one isolated instance. LIF slopes were comparable between frequencies, ranging from 0.020 to 0.030 msec/dB. These normal LIFs for high-frequency tone burst-evoked ABRs suggest the degree of response latency change that might be expected from, for example, progressive hearing loss due to ototoxic insult, although these phenomena may not be directly related.
Yuantai Hu; Huiliang Hu; Bin Luo; Huan Xue; Jiemin Xie; Ji Wang
2013-08-01
A two-dimensional model was established to study the dynamic characteristics of a quartz crystal resonator with the upper surface covered by an array of hemispherical material units. A frequency-dependent equivalent mass ratio was proposed to simulate the effect of the covered units on frequency shift of the resonator system. It was found that the equivalent mass ratio alternately becomes positive or negative with change of shear modulus and radius of each material unit, which indicates that the equivalent mass ratio is strongly related to the vibration mode of the covered loadings. The further numerical results show the cyclical feature in the relationship of frequency shift and shear modulus/radius as expected. The solutions are useful in the analysis of frequency stability of quartz resonators and acoustic wave sensors.
McCamant, David W
2011-07-28
This work presents a theoretical treatment of the vibrational line shape generated in a femtosecond stimulated Raman spectroscopy (FSRS) experiment under conditions in which the probed vibration undergoes a significant frequency shift during its free induction decay. This theory is applied to simulate the FSRS lineshapes previously observed in rhodopsin (Kukura et al. Science 2005, 310, 1006). The previously determined relaxation times for formation of the trans-photoproduct of rhodopsin were calculated using an incorrect equation for the time dependence of the observed frequency shifts. Here the data are reanalyzed by calculation of the corrected frequency sweep occurring during the vibrational free induction decay. It is shown that the calculated frequency shifts and general conclusions of the original work are sound but that the coherent vibrational frequency shifts of the C(10), C(11), and C(12) hydrogen-out-of-plane vibrations occur with a 140 fs time constant rather than the previously reported 325 fs time constant. This time constant provides an important constraint for models of the dynamics of the cis to trans isomerization process. © 2011 American Chemical Society
Potential objective biomarkers for fatigue among working women
Ebata, Chie; Tatsuta, Hitomi; Tatemichi, Masayuki
2017-01-01
Objective: The prediction of health impairment due to work overload is subjectively assessed based on recognized symptoms; however, objective evaluation is primarily ideal in the field of occupational health. Recently, some biomarkers of autonomic function and/or oxidative stress were reported to be associated with fatigue. This study aimed to preliminarily investigate whether these biomarkers could be objective indicators for fatigue and stress among working women. Method: Participants included 118 full-time female workers (mean age 37.8 years), including 55 shift workers. Self-administered questionnaires, such as visual analog scale (VAS) for general health, a lifestyle questionnaire, SF-8 for health-related quality of life, and K6 for mental health screening, were used. In addition, biomarkers such as acceleration plethysmogram (APG), reactive oxygen metabolites-derived compounds (d-ROMs), and biological antioxidant potential (BAP) were measured. Results: A significant association was observed between BAP and VAS (r=0.482, p<0.01) among shift workers. However, other biomarkers such as APG and d-ROMs were not significantly associated with symptoms. d-ROMs were significantly correlated with age and body mass index. There was a significant negative correlation between BAP and smoking. Results of the APG (low-frequency (LF) /high-frequency (HF) ratio) were significantly correlated with BAP, but not with d-ROMs. The LF/HF ratio and BAP for shift workers were significantly higher than those for day-time workers. Conclusions: Our results suggest that APG and BAP are potential objective biomarkers for fatigue among working women, although further follow-up studies are needed to clarify the scope of usefulness of the biomarkers for fatigue. PMID:28163282
Potential objective biomarkers for fatigue among working women.
Ebata, Chie; Tatsuta, Hitomi; Tatemichi, Masayuki
2017-05-25
The prediction of health impairment due to work overload is subjectively assessed based on recognized symptoms; however, objective evaluation is primarily ideal in the field of occupational health. Recently, some biomarkers of autonomic function and/or oxidative stress were reported to be associated with fatigue. This study aimed to preliminarily investigate whether these biomarkers could be objective indicators for fatigue and stress among working women. Participants included 118 full-time female workers (mean age 37.8 years), including 55 shift workers. Self-administered questionnaires, such as visual analog scale (VAS) for general health, a lifestyle questionnaire, SF-8 for health-related quality of life, and K6 for mental health screening, were used. In addition, biomarkers such as acceleration plethysmogram (APG), reactive oxygen metabolites-derived compounds (d-ROMs), and biological antioxidant potential (BAP) were measured. A significant association was observed between BAP and VAS (r=0.482, p<0.01) among shift workers. However, other biomarkers such as APG and d-ROMs were not significantly associated with symptoms. d-ROMs were significantly correlated with age and body mass index. There was a significant negative correlation between BAP and smoking. Results of the APG (low-frequency (LF) /high-frequency (HF) ratio) were significantly correlated with BAP, but not with d-ROMs. The LF/HF ratio and BAP for shift workers were significantly higher than those for day-time workers. Our results suggest that APG and BAP are potential objective biomarkers for fatigue among working women, although further follow-up studies are needed to clarify the scope of usefulness of the biomarkers for fatigue.
Hyper-Ramsey spectroscopy of optical clock transitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yudin, V. I.; Taichenachev, A. V.; Oates, C. W.
2010-07-15
We present nonstandard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties can be radically suppressed (by two to four orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case, these frequency shifts can be suppressed considerably below a fractional levelmore » of 10{sup -17}. Moreover, our approach opens the door for high-precision optical clocks based on direct frequency comb spectroscopy.« less
Initial atomic coherences and Ramsey frequency pulling in fountain clocks
NASA Astrophysics Data System (ADS)
Gerginov, Vladislav; Nemitz, Nils; Weyers, Stefan
2014-09-01
In the uncertainty budget of primary atomic cesium fountain clocks, evaluations of frequency-pulling shifts of the hyperfine clock transition caused by unintentional excitation of its nearby transitions (Rabi and Ramsey pulling) have been based so far on an approach developed for cesium beam clocks. We re-evaluate this type of frequency pulling in fountain clocks and pay particular attention to the effect of initial coherent atomic states. We find significantly enhanced frequency shifts caused by Ramsey pulling due to sublevel population imbalance and corresponding coherences within the state-selected hyperfine component of the initial atom ground state. Such shifts are experimentally investigated in an atomic fountain clock and quantitative agreement with the predictions of the model is demonstrated.
NASA Astrophysics Data System (ADS)
Poulain, Pierre-Marie; Luther, Douglas S.; Patzert, William C.
1992-11-01
Two techniques have been developed for estimating statistics of inertial oscillations from satellite-tracked drifters. These techniques overcome the difficulties inherent in estimating such statistics from data dependent upon space coordinates that are a function of time. Application of these techniques to tropical surface drifter data collected during the NORPAX, EPOCS, and TOGA programs reveals a latitude-dependent, statistically significant "blue shift" of inertial wave frequency. The latitudinal dependence of the blue shift is similar to predictions based on "global" internal wave spectral models, with a superposition of frequency shifting due to modification of the effective local inertial frequency by the presence of strongly sheared zonal mean currents within 12° of the equator.
Airy pulse shaping using time-dependent power-law potentials
NASA Astrophysics Data System (ADS)
Han, Tianwen; Chen, Hao; Qin, Chengzhi; Li, Wenwan; Wang, Bing; Lu, Peixiang
2018-06-01
We investigate the temporal and spectral evolutions of finite-energy Airy pulses in the presence of power-law optical potentials. The potentials are generated by the time-dependent pumped light, which propagates together with the Airy pulses in a highly nonlinear optical fiber. We show that the intrinsic acceleration of Airy pulses can be modified by an external force that stems from a linear potential, and hence unidirectional frequency shift can be realized. When a triangle potential is employed, the pulse will exhibit self-splitting both in temporal and spectral domains. Additionally, as a parabolic potential is utilized, both the temporal waveform and frequency spectrum of the Airy pulse will exchange alternately between the Airy and Gaussian profiles. By using higher-order power-law potentials, we also realize both revival and antirevival effects for the Airy pulses. The study may find wide applications in pulse reshaping and spectral-temporal imaging for both optical communication and signal processing.
Kingni, Sifeu Takougang; Mbé, Jimmi Hervé Talla; Woafo, Paul
2012-09-01
In this work, we numerically study the dynamics of vertical cavity surface emitting laser (VCSEL) firstly when it is driven by Chua's oscillator, secondly in case where it is driven by a broad frequency spectral bandwidth chaotic oscillator developed by Nana et al. [Commun. Nonlinear Sci. Numer. Simul. 14, 2266 (2009)]. We demonstrated that the VCSEL generated robust chaotic dynamics compared to the ones found in VCSEL subject to a sinusoidally modulated current and therefore it is more suitable for chaos encryption techniques. The synchronization characteristics and the communication performances of unidirectional coupled VCSEL driven by the broad frequency spectral bandwidth chaotic oscillators are investigated numerically. The results show that high-quality synchronization and transmission of messages can be realized for suitable system parameters. Chaos shift keying method is successfully applied to encrypt a message at a high bitrate.
Fukumura, Tomoe; Yoshita, Katsushi; Tabata, Masaji
2015-01-01
The purpose of this study was to understand the actual state of life hours (working time, sleep time, and time of meal intake) and dietary habits of male shift work employees, and to elucidate the impact of working arrangements and dietary habits on their physical condition and health problems. The subjects were 187 male employees (aged 18-64 years) working for an industrial company in Toyama prefecture. We used a self-administered questionnaire to assess dietary habit, lifestyle habits, and life hours at the time of a periodic health examination in April 2013. The subjects were grouped based on their working condition (i.e., day shift, late shift, and late-night shift) into two groups of day shift (n = 107) and shiftwork (n = 80). The proportion of time spent sleeping and feeding was determined in half hour increments, and the incidences of skipping meals (breakfast, lunch and dinner) and midnight snack intake were calculated for each working condition. We also examined the association between the frequency of eating and physical condition for each working condition. The state of life hours of the shiftwork group during the day was similar to that of the day shift group. However, the workers' state of life hours, incidences of skipping meals, and midnight snack intake varied considerably when working at the other shift times. In the shiftwork group, regardless of the working patterns, the BMI and % body fat of the group that ate more than three times a day were significantly lower than those of the group that ate less than twice a day. The results of the present study suggest that it is difficult to ensure the time and opportunity for meals for shift workers. We consider that it is necessary to prevent them skipping of meals, and to support a proper dietary intake during the night.
Analysis of frequency shifting in seismic signals using Gabor-Wigner transform
NASA Astrophysics Data System (ADS)
Kumar, Roshan; Sumathi, P.; Kumar, Ashok
2015-12-01
A hybrid time-frequency method known as Gabor-Wigner transform (GWT) is introduced in this paper for examining the time-frequency patterns of earthquake damaged buildings. GWT is developed by combining the Gabor transform (GT) and Wigner-Ville distribution (WVD). GT and WVD have been used separately on synthetic and recorded earthquake data to identify frequency shifting due to earthquake damages, but GT is prone to windowing effect and WVD involves ambiguity function. Hence to obtain better clarity and to remove the cross terms (frequency interference), GT and WVD are judiciously combined and the resultant GWT used to identify frequency shifting. Synthetic seismic response of an instrumented building and real-time earthquake data recorded on the building were investigated using GWT. It is found that GWT offers good accuracy for even slow variations in frequency, good time-frequency resolution, and localized response. Presented results confirm the efficacy of GWT when compared with GT and WVD used separately. Simulation results were quantified by the Renyi entropy measures and GWT shown to be an adequate technique in identifying localized response for structural damage detection.
Mating system shifts and transposable element evolution in the plant genus Capsella.
Agren, J Ågren; Wang, Wei; Koenig, Daniel; Neuffer, Barbara; Weigel, Detlef; Wright, Stephen I
2014-07-16
Despite having predominately deleterious fitness effects, transposable elements (TEs) are major constituents of eukaryote genomes in general and of plant genomes in particular. Although the proportion of the genome made up of TEs varies at least four-fold across plants, the relative importance of the evolutionary forces shaping variation in TE abundance and distributions across taxa remains unclear. Under several theoretical models, mating system plays an important role in governing the evolutionary dynamics of TEs. Here, we use the recently sequenced Capsella rubella reference genome and short-read whole genome sequencing of multiple individuals to quantify abundance, genome distributions, and population frequencies of TEs in three recently diverged species of differing mating system, two self-compatible species (C. rubella and C. orientalis) and their self-incompatible outcrossing relative, C. grandiflora. We detect different dynamics of TE evolution in our two self-compatible species; C. rubella shows a small increase in transposon copy number, while C. orientalis shows a substantial decrease relative to C. grandiflora. The direction of this change in copy number is genome wide and consistent across transposon classes. For insertions near genes, however, we detect the highest abundances in C. grandiflora. Finally, we also find differences in the population frequency distributions across the three species. Overall, our results suggest that the evolution of selfing may have different effects on TE evolution on a short and on a long timescale. Moreover, cross-species comparisons of transposon abundance are sensitive to reference genome bias, and efforts to control for this bias are key when making comparisons across species.
Ottenvall Hammar, Isabelle; Dahlin-Ivanoff, Synneve; Wilhelmson, Katarina; Eklund, Kajsa
2014-11-28
Older persons' right to exercise self-determination in daily life is supported by several laws. Research shows that older persons' self-determination is not fully respected within the healthcare sector. In order to enable and enhance older persons' self-determination, extensive knowledge of older persons' self-determination is needed. The aim of this study was to explore experiences of self-determination when developing dependence in daily activities among community-dwelling persons 80 years and older. Qualitative interviews were performed in accordance with a grounded theory method, with 11 persons aged 84-95 years who were beginning to develop dependence in daily activities. The data analysis revealed the core category, "Self-determination - shifting between self-governing and being governed". The core category comprised three categories: "Struggling against the aging body", "Decision-making is relational", and "Guarding one's own independence". Self-determination in daily activities was related to a shifting, which was two-fold, and varied between self-governing and being governed by the aging body, or by others. The findings imply a need to adopt a person-centered approach where the older persons' own preferences and needs are in focus, in order to enhance their possibilities to exercise self-determination.
DNA Dispose, but Subjects Decide. Learning and the Extended Synthesis.
Lindholm, Markus
Adaptation by means of natural selection depends on the ability of populations to maintain variation in heritable traits. According to the Modern Synthesis this variation is sustained by mutations and genetic drift. Epigenetics, evodevo, niche construction and cultural factors have more recently been shown to contribute to heritable variation, however, leading an increasing number of biologists to call for an extended view of speciation and evolution. An additional common feature across the animal kingdom is learning, defined as the ability to change behavior according to novel experiences or skills. Learning constitutes an additional source for phenotypic variation, and change in behavior may induce long lasting shifts in fitness, and hence favor evolutionary novelties. Based on published studies, I demonstrate how learning about food, mate choice and habitats has contributed substantially to speciation in the canonical story of Darwin's finches on the Galapagos Islands. Learning cannot be reduced to genetics, because it demands decisions, which requires a subject. Evolutionary novelties may hence emerge both from shifts in allelic frequencies and from shifts in learned, subject driven behavior. The existence of two principally different sources of variation also prevents the Modern Synthesis from self-referring explanations.
Frank, T
2001-04-01
The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.
Hoehmann, D; Müller, S; Dornhoffer, J L
1995-01-01
Low-frequency acoustic biasing using an intensive phase-shifted, low-frequency masker was studied according to its ability to determine disorders of cochlear micromechanics following noise trauma in the guinea pig as animal model. Statistical analyses proved that this technique allowed electrophysiological differentiation of controls versus groups with different degrees of experimentally induced threshold shifts. To substantiate group differences an intensity of at least 70 dB SPL was required for the 52 Hz masker and the difference in relation to the test-tone intensity had to be +/- 10 or +/- 20 dB SPL. The noise-traumatized cochlea could be identified by means of a threshold shift for the 5 microV pseudothreshold, a low modulation span of the compound action potential amplitude (< 25-50 microV frequency dependent), and reduced positive summating potential amplitude with negative non-modulating values within the different measurement phases for 1 and 2 kHz stimulation.
Turgut, Altan; Orr, Marshall; Pasewark, Bruce
2007-05-01
Waveguide invariant theory is used to describe the frequency shifts of constant acoustic intensity level curves in broadband signal spectrograms measured at the New Jersey Shelf during the winter of 2003. The broadband signals (270-330 Hz) were transmitted from a fixed source and received at three fixed receivers, located at 10, 20, and 30 km range along a cross-shelf propagation track. The constant acoustic intensity level curves of the received signals indicate regular frequency shifts that can be well predicted by the change in water depth observed through tens of tidal cycles. A second pattern of frequency shifts is observed at only 30 km range where significant variability of slope-water intrusion was measured. An excellent agreement between observed frequency shifts of the constant acoustic intensity levels and those predicted by the change in tide height and slope water elevations suggests the capability of long-term acoustic monitoring of tide and slope water intrusions in winter conditions.
Santillan, Arturo O; Cutanda-Henríquez, Vicente
2008-11-01
An investigation on the resonance frequency shift for a plane-wave mode in a cylindrical cavity produced by a rigid sphere is reported in this paper. This change of the resonance frequency has been previously considered as a cause of oscillational instabilities in single-mode acoustic levitation devices. It is shown that the use of the Boltzmann-Ehrenfest principle of adiabatic invariance allows the derivation of an expression for the resonance frequency shift in a simpler and more direct way than a method based on a Green's function reported in literature. The position of the sphere can be any point along the axis of the cavity. Obtained predictions of the resonance frequency shift with the deduced equation agree quite well with numerical simulations based on the boundary element method. The results are also confirmed by experiments. The equation derived from the Boltzmann-Ehrenfest principle appears to be more general, and for large spheres, it gives a better approximation than the equation previously reported.
The Effect of Shift Work on Urogenital Disease: a Systematic Review.
Deng, Nanfu; Haney, Nora M; Kohn, Taylor P; Pastuszak, Alexander W; Lipshultz, Larry I
2018-05-28
Non-standard shift work schedules negatively impact the overall health of shift workers, and several studies have shown that shift work, specifically, is detrimental to urogenital health. The aims of this study are to systematically review the literature and determine the effect of shift work on the outcomes of hypogonadism, male infertility, lower urinary tract symptoms, and urogenital cancers. Recent evidence supports associations between non-standard shift work and an increase in the frequency of prostate cancer and the severity of erectile dysfunction, lower urinary tract symptoms, and hypogonadal symptoms, as well as worsening of semen parameters and fertility. These associations are strengthened by the presence of shift work sleep disorder (SWSD) which affects up to 20% of shift workers. No studies have assessed the impact of shift work on the frequency or severity of nephrolithiasis, interstitial cystitis, pelvic pain, prostatitis, or urinary tract infections. Non-standard shift work has been associated with a variety of negative health outcomes and urologic complications, especially with concurrent shift work sleep disorder. Recognition of these elevated risks among shift workers can aid in more effective screening for urologic conditions.
Yang, R G; Zhang, J; Zhai, Z H; Zhai, S Q; Liu, K; Gao, J R
2015-08-10
Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.
Seismic sensitivity to sub-surface solar activity from 18 yr of GOLF/SoHO observations
NASA Astrophysics Data System (ADS)
Salabert, D.; García, R. A.; Turck-Chièze, S.
2015-06-01
Solar activity has significantly changed over the last two Schwabe cycles. After a long and deep minimum at the end of Cycle 23, the weaker activity of Cycle 24 contrasts with the previous cycles. In this work, the response of the solar acoustic oscillations to solar activity is used in order to provide insights into the structural and magnetic changes in the sub-surface layers of the Sun during this on-going unusual period of low activity. We analyze 18 yr of continuous observations of the solar acoustic oscillations collected by the Sun-as-a-star GOLF instrument on board the SoHO spacecraft. From the fitted mode frequencies, the temporal variability of the frequency shifts of the radial, dipolar, and quadrupolar modes are studied for different frequency ranges that are sensitive to different layers in the solar sub-surface interior. The low-frequency modes show nearly unchanged frequency shifts between Cycles 23 and 24, with a time evolving signature of the quasi-biennial oscillation, which is particularly visible for the quadrupole component revealing the presence of a complex magnetic structure. The modes at higher frequencies show frequency shifts that are 30% smaller during Cycle 24, which is in agreement with the decrease observed in the surface activity between Cycles 23 and 24. The analysis of 18 yr of GOLF oscillations indicates that the structural and magnetic changes responsible for the frequency shifts remained comparable between Cycle 23 and Cycle 24 in the deeper sub-surface layers below 1400 km as revealed by the low-frequency modes. The frequency shifts of the higher-frequency modes, sensitive to shallower regions, show that Cycle 24 is magnetically weaker in the upper layers of Sun. Appendices are available in electronic form at http://www.aanda.orgThe following 68 GOLF frequency tables are available and Table A.1 is also available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/578/A137
Modeling perspectives on echolocation strategies inspired by bats flying in groups.
Lin, Yuan; Abaid, Nicole
2015-12-21
Bats navigating with echolocation - which is a type of active sensing achieved by interpreting echoes resulting from self-generated ultrasonic pulses - exhibit unique behaviors during group flight. While bats may benefit from eavesdropping on their peers׳ echolocation, they also potentially suffer from confusion between their own and peers׳ pulses, caused by an effect called frequency jamming. This hardship of group flight is supported by experimental observations of bats simplifying their sound-scape by shifting their pulse frequencies or suppressing echolocation altogether. Here, we investigate eavesdropping and varying pulse emission rate from a modeling perspective to understand these behaviors׳ potential benefits and detriments. We define an agent-based model of echolocating bats avoiding collisions in a three-dimensional tunnel. Through simulation, we show that bats with reasonably accurate eavesdropping can reduce collisions compared to those neglecting information from peers. In large populations, bats minimize frequency jamming by decreasing pulse emission rate, while collision risk increases; conversely, increasing pulse emission rate minimizes collisions by allowing more sensing information generated per bat. These strategies offer benefits for both biological and engineered systems, since frequency jamming is a concern in systems using active sensing. Copyright © 2015 Elsevier Ltd. All rights reserved.
The effect of cockpit noise on the temporary threshold shift of Cessna 172SP flight instructors
NASA Astrophysics Data System (ADS)
Bellini, Andrew Robert
The purpose of this thesis was to study the temporary threshold shift of general aviation flight instructors resulting from their working environment. Exposure to noise before a temporary threshold shift completely recovers can cause a permanent threshold shift with no possibility of recovery, resulting in permanent hearing loss. A result showing minimal to no temporary threshold shift would indicate that hearing personal protective equipment is working properly. This study used sound-level measurements, and audiometric testing, together with survey data to determine whether or not flight instructors were at risk for potential hearing impairment due to temporary threshold shift. Independent t-tests and descriptive statistics were used in analyzing the data. It was determined that there was a difference in temporary threshold shift based on the number of hours a flight instructor flies in a Cessna 172SP for only one frequency - 2000Hz in the left ear. All other frequencies tested in both ears showed no difference. Because there was a very low mean temporary threshold shift at 2000Hz in the left ear and no differences shown for all other frequencies in both ears, it was concluded that there was no need to improve or require additional hearing personal protective equipment, or to require decreased exposure times to aircraft noise.
Influence of the ac-Stark shift on GPS atomic clock timekeeping
NASA Astrophysics Data System (ADS)
Formichella, V.; Camparo, J.; Tavella, P.
2017-01-01
The ac-Stark shift (or light shift) is a fundamental aspect of the field/atom interaction arising from virtual transitions between atomic states, and as Alfred Kastler noted, it is the real-photon counterpart of the Lamb shift. In the rubidium atomic frequency standards (RAFS) flying on Global Positioning System (GPS) satellites, it plays an important role as one of the major perturbations defining the RAFS' frequency: the rf-discharge lamp in the RAFS creates an atomic signal via optical pumping and simultaneously perturbs the atoms' ground-state hyperfine splitting via the light shift. Though the significance of the light shift has been known for decades, to date there has been no concrete evidence that it limits the performance of the high-quality RAFS flying on GPS satellites. Here, we show that the long-term frequency stability of GPS RAFS is primarily determined by the light shift as a consequence of stochastic jumps in lamplight intensity. Our results suggest three paths forward for improved GPS system timekeeping: (1) reduce the light-shift coefficient of the RAFS by careful control of the lamp's spectrum; (2) operate the lamp under conditions where lamplight jumps are not so pronounced; and (3) employ a light source for optical pumping that does not suffer pronounced light jumps (e.g., a diode laser).
NASA Astrophysics Data System (ADS)
Zhu, Zihang; Zhao, Shanghong; Li, Xuan; Lin, Tao; Hu, Dapeng
2018-03-01
Photonic microwave frequency down-conversion with independent multichannel phase shifting and zero-intermediate frequency (IF) receiving is proposed and demonstrated by simulation. By combined use of a phase modulator (PM) in a sagnac loop and an optical bandpass filter (OBPF), orthogonal polarized carrier suppression single sideband (CS-SSB) signals are obtained. By adjusting the polarization controllers (PCs) to introduce the phase difference in the optical domain and using balanced detection to eliminate the direct current components, the phase of the generated IF signal can be arbitrarily tuned. Besides, the radio frequency (RF) vector signal can be also frequency down-converted to baseband directly by choosing two quadrature channels. In the simulation, high gain and continuously tunable phase shifts over the 360 degree range are verified. Furthermore, 2.5 Gbit/s RF vector signals centered at 10 GHz with different modulation formats are successfully demodulated.
Design and Processing of a Novel Chaos-Based Stepped Frequency Synthesized Wideband Radar Signal.
Zeng, Tao; Chang, Shaoqiang; Fan, Huayu; Liu, Quanhua
2018-03-26
The linear stepped frequency and linear frequency shift keying (FSK) signal has been widely used in radar systems. However, such linear modulation signals suffer from the range-Doppler coupling that degrades radar multi-target resolution. Moreover, the fixed frequency-hopping or frequency-coded sequence can be easily predicted by the interception receiver in the electronic countermeasures (ECM) environments, which limits radar anti-jamming performance. In addition, the single FSK modulation reduces the radar low probability of intercept (LPI) performance, for it cannot achieve a large time-bandwidth product. To solve such problems, we propose a novel chaos-based stepped frequency (CSF) synthesized wideband signal in this paper. The signal introduces chaotic frequency hopping between the coherent stepped frequency pulses, and adopts a chaotic frequency shift keying (CFSK) and phase shift keying (PSK) composited coded modulation in a subpulse, called CSF-CFSK/PSK. Correspondingly, the processing method for the signal has been proposed. According to our theoretical analyses and the simulations, the proposed signal and processing method achieve better multi-target resolution and LPI performance. Furthermore, flexible modulation is able to increase the robustness against identification of the interception receiver and improve the anti-jamming performance of the radar.
NASA Technical Reports Server (NTRS)
Sanders, Steven (Inventor); Waarts, Robert G. (Inventor)
2001-01-01
A frequency conversion system comprises first and second gain sources providing first and second frequency radiation outputs where the second gain source receives as input the output of the first gain source and, further, the second gain source comprises a Raman or Brillouin gain fiber for wave shifting a portion of the radiation of the first frequency output into second frequency radiation output to provided a combined output of first and second frequencies. Powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.
Doppler-shifted self-reflected wave from a semiconductor
NASA Astrophysics Data System (ADS)
Schuelzgen, Alex; Hughes, S.; Peyghambarian, Nasser
1997-06-01
We report the first experimental observation of a self- reflected wave inside a very dense saturable absorber. An intense femtosecond pulse saturates the absorption and causes a density front moving into the semiconductor sample. Due to the motion of the boundary between saturated and unsaturated areas of the sample the light reflected at this boundary is red-shifted by the Doppler effect. The spectrally shifted reflection makes it possible to distinguish between surface reflection and self-reflection and is used to proof the concept of the dynamic nonlinear skin effect experimentally. Quite well agreement with model calculations is found.
Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS
NASA Astrophysics Data System (ADS)
Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru
2016-04-01
The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2-8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshmukh, Sanket; Solomon, Lee A.; Kamath, Ganesh
Understanding the role of water in governing the kinetics of the self-assembly processes of amphiphilic peptides has still remained elusive. Here, using a multi-stage atomistic-coarse-grained approach, complemented by circular dichroism/infra-red spectroscopy and dynamic light scattering experiments, we highlight the dual nature of water in dictating the mechanism and dynamics of self-assembly of peptide amphiphiles (PAs). Our computational study shows that (i) Water cage formation and breakage near the hydrophobic groups controls the fusion dynamics and aggregation of PAs in the micellar stage, and (ii) Enhanced structural ordering of vicinal water near the hydrophilic amino acids shifts the equilibrium towards themore » fiber phase and stimulates structure and order in the PAs when they assemble into a hexagonal nanofiber architecture. Finally, spectroscopy and microscopy studies authenticate our computational observation that water ordering near the PAs increases with increase in time. The measured infra-red O-H bond stretch frequency reminiscent of ice-like suggests that the solvated water becomes increasingly solid-like with increased structural order in the assembled peptide network – thus shedding light on the role of water in a self-assembly process.« less
Deshmukh, Sanket; Solomon, Lee A.; Kamath, Ganesh; ...
2016-08-24
Understanding the role of water in governing the kinetics of the self-assembly processes of amphiphilic peptides has still remained elusive. Here, using a multi-stage atomistic-coarse-grained approach, complemented by circular dichroism/infra-red spectroscopy and dynamic light scattering experiments, we highlight the dual nature of water in dictating the mechanism and dynamics of self-assembly of peptide amphiphiles (PAs). Our computational study shows that (i) Water cage formation and breakage near the hydrophobic groups controls the fusion dynamics and aggregation of PAs in the micellar stage, and (ii) Enhanced structural ordering of vicinal water near the hydrophilic amino acids shifts the equilibrium towards themore » fiber phase and stimulates structure and order in the PAs when they assemble into a hexagonal nanofiber architecture. Finally, spectroscopy and microscopy studies authenticate our computational observation that water ordering near the PAs increases with increase in time. The measured infra-red O-H bond stretch frequency reminiscent of ice-like suggests that the solvated water becomes increasingly solid-like with increased structural order in the assembled peptide network – thus shedding light on the role of water in a self-assembly process.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dmitriev, A K; Konovalov, A N; Ul'yanov, V A
2014-04-28
We report an experimental study of the self-mixing effect in a single-mode multifrequency erbium fibre laser when radiation backscattered from an external moving object arrives at its cavity. To eliminate resulting chaotic pulsations in the laser, we have proposed a technique for suppressing backscattered radiation through the use of multimode fibre for radiation delivery. The multifrequency operation of the laser has been shown to lead to strong fluctuations of the amplitude of the Doppler signal and a nonmonotonic variation of the amplitude with distance to the scattering object. In spite of these features, the self-mixing signal was detected with amore » high signal-to-noise ratio (above 10{sup 2}) when the radiation was scattered by a rotating disc, and the Doppler frequency shift, evaluated as the centroid of its spectrum, had high stability (0.15%) and linearity relative to the rotation rate. We conclude that the self-mixing effect in this type of fibre laser can be used for measuring the velocity of scattering objects and in Doppler spectroscopy for monitoring the laser evaporation of materials and biological tissues. (control of laser radiation parameters)« less
Product self-management: evolution in recycling and reuse.
Thomas, Valerie M
2003-12-01
This paper explores the potential to make product recycling and reuse easier by shifting responsibility for product management toward the product itself. Examples range from barcode-enabled Internet sales of used products to RFID-enabled garbage trucks that identify recyclable items and provide rebates. Initial steps toward product self-management have made opportunistic use of product bar codes and Internet markets. In the United States, Internet markets are driving increased reuse of products. In the European Union, recycling and waste management policy is driving the use of radio electronics in waste management. Prospects for product self-management are assessed from both a technological and an economic perspective. The technological analysis indicates that radio-frequency tags offer some advantages over bar codes, but their application to product self-management requires considerable investment in the waste management infrastructure. This suggests that early applications of advanced product tags are most suitable for Germany and other countries where the waste management industry has already integrated information technology into its operations. The economic analysis indicates that increased reuse of products can reduce consumption of new products and materials, although on a less than one-to-one basis, simultaneously reducing costs for consumers and deriving more value from existing products.
The impact of shift work on nurses' job stress, sleep quality and self-perceived health status.
Lin, Shu-Hui; Liao, Wen-Chun; Chen, Mei-Yen; Fan, Jun-Yu
2014-07-01
The aim of this study was to describe the current state of nurses' shift work in Taiwan and how it affects nurses' stress, sleep quality and self-perceived health status. To enable the provision of 24-hour patient care, nurses need to work various shifts. Long-term shift work significantly affects nurses' overall physical and mental health. Nurses from four Chiayi County district hospitals in Taiwan (n = 266) participated in this cross-sectional study from August to September 2010. Demographics, work schedule forms, a stress checklist, a sleep-quality measure and a health-status measure were used to collect data. Independent t-test, one-way anova, Pearson's r, and hierarchical regression were applied for analysis. The results showed that regardless of the amount of shift work they performed, nurses reported moderate job stress, poor sleep quality and moderate self-perceived health. The following significant relationships were observed: job stress was inversely related to sleep quality, which was directly related to self-perceived health status. Hospital managers need to ensure more healthy shift work scheduling in order to improve nurses' clinical performance and personal health status, thereby also improving the quality of patient care. © 2012 John Wiley & Sons Ltd.
Frequency stabilization in nonlinear MEMS and NEMS oscillators
Lopez, Omar Daniel; Antonio, Dario
2014-09-16
An illustrative system includes an amplifier operably connected to a phase shifter. The amplifier is configured to amplify a voltage from an oscillator. The phase shifter is operably connected to a driving amplitude control, wherein the phase shifter is configured to phase shift the amplified voltage and is configured to set an amplitude of the phase shifted voltage. The oscillator is operably connected to the driving amplitude control. The phase shifted voltage drives the oscillator. The oscillator is at an internal resonance condition, based at least on the amplitude of the phase shifted voltage, that stabilizes frequency oscillations in the oscillator.
Modification of optical properties by adiabatic shifting of resonances in a four-level atom
NASA Astrophysics Data System (ADS)
Dutta, Bibhas Kumar; Panchadhyayee, Pradipta
2018-04-01
We describe the linear and nonlinear optical properties of a four-level atomic system, after reducing it to an effective two-level atomic model under the condition of adiabatic shifting of resonances driven by two coherent off-resonant fields. The reduced form of the Hamiltonian corresponding to the two-level system is obtained by employing an adiabatic elimination procedure in the rate equations of the probability amplitudes for the proposed four-level model. For a weak probe field operating in the system, the nonlinear dependence of complex susceptibility on the Rabi frequencies and the detuning parameters of the off-resonant driving fields makes it possible to exhibit coherent control of single-photon and two-photon absorption and transparency, the evolution of enhanced Self-Kerr nonlinearity and noticeable dispersive switching. We have shown how the quantum interference results in the generic four-level model at the adiabatic limit. The present scheme describes the appearance of single-photon transparency without invoking any exact two-photon resonance.
Comprehensive time average digital holographic vibrometry
NASA Astrophysics Data System (ADS)
Psota, Pavel; Lédl, Vít; Doleček, Roman; Mokrý, Pavel; Vojtíšek, Petr; Václavík, Jan
2016-12-01
This paper presents a method that simultaneously deals with drawbacks of time-average digital holography: limited measurement range, limited spatial resolution, and quantitative analysis of the measured Bessel fringe patterns. When the frequency of the reference wave is shifted by an integer multiple of frequency at which the object oscillates, the measurement range of the method can be shifted either to smaller or to larger vibration amplitudes. In addition, phase modulation of the reference wave is used to obtain a sequence of phase-modulated fringe patterns. Such fringe patterns can be combined by means of phase-shifting algorithms, and amplitudes of vibrations can be straightforwardly computed. This approach independently calculates the amplitude values in every single pixel. The frequency shift and phase modulation are realized by proper control of Bragg cells and therefore no additional hardware is required.
Doppler lidar wind measurement with the edge technique
NASA Technical Reports Server (NTRS)
Korb, C. Laurence; Gentry, Bruce M.
1992-01-01
The edge technique is a new and powerful method for measuring small frequency shifts. Range resolved lidar measurements of winds can be made with high accuracy and high vertical resolution using the edge technique to measure the Doppler shift of an atmospheric backscattered signal from a pulsed laser. The edge technique can be used at near-infrared or visible wavelengths using well developed solid state lasers and detectors with various edge filters. In the edge technique, the laser frequency is located on the steep slope of the spectral response function of a high resolution optical filter. Due to the steep slope of the edge, very small frequency shifts cause large changes in measured signal. The frequency of the outgoing laser pulse is determined by measuring its location on the edge of the filter. This is accomplished by sending a small portion of the beam to the edge detection setup where the incoming light is split into two channels - an edge filter and an energy monitor channel. The energy monitor signal is used to normalize the edge filter signal for magnitude. The laser return backscattered from the atmosphere is collected by a telescope and directed through the edge detection setup to determine its frequency (location on the edge) in a similar manner for each range element. The Doppler shift, and thus the wind, is determined from a differential measurement of the frequency of the outgoing laser pulse and the frequency of the laser return backscattered from the atmosphere. We have conducted simulations of the performance of an edge lidar system using an injection seeded pulsed Nd:YAG laser at 1.06 microns. The central fringe of a Fabry-Perot etalon is used as a high resolution edge filter to measure the shift of the aerosol return.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foullon, C.; Nakariakov, V. M.
2010-05-01
The discovery that p-mode frequencies of low degree do not follow changes of solar surface activity during the recent solar minimum offers the possibility of a new diagnostic signature of the responsible pressure perturbation in the wave guiding medium, potentially rich of information regarding the structure of the Sun and the cause of the unusually long solar minimum. Magnetic fields, as well as temperature changes, introduce equilibrium pressure deviations that modify the resonant frequencies of p-mode oscillations. Assuming the perturbation to be caused by a horizontal layer of magnetic field located in a plane-stratified model of the Sun, we compilemore » analytical frequency shifts and process them to allow direct comparison with observations. The effect of magnetism itself on the central p-mode frequencies can be neglected in comparison with the thermal effect of a perturbative layer buried in the solar interior. A parametric study shows that a layer as thin as 2100 km at subsurface depths is able to reproduce reported mean anomalous frequency shifts (not correlated with the surface activity), while a layer of size around 4200 km increasing by a small amount at depths near 0.08 R {sub sun} can explain individual low-degree shifts. It is also possible to obtain the mean shifts via the upward motion through depths near 0.03 R {sub sun} of a rising perturbative layer of thickness around 7000 km. Hence, the anomalous frequency shifts are best explained by thermal effects in the upper regions of the convection zone. The effects of latitudinal distribution are not treated here.« less
Temporal Genetic Dynamics of an Experimental, Biparental Field Population of Phytophthora capsici
Carlson, Maryn O.; Gazave, Elodie; Gore, Michael A.; Smart, Christine D.
2017-01-01
Defining the contributions of dispersal, reproductive mode, and mating system to the population structure of a pathogenic organism is essential to estimating its evolutionary potential. After introduction of the devastating plant pathogen, Phytophthora capsici, into a grower’s field, a lack of aerial spore dispersal restricts migration. Once established, coexistence of both mating types results in formation of overwintering recombinant oospores, engendering persistent pathogen populations. To mimic these conditions, in 2008, we inoculated a field with two P. capsici isolates of opposite mating type. We analyzed pathogenic isolates collected in 2009–2013 from this experimental population, using genome-wide single-nucleotide polymorphism markers. By tracking heterozygosity across years, we show that the population underwent a generational shift; transitioning from exclusively F1 in 2009–2010, to multi-generational in 2011, and ultimately all inbred in 2012–2013. Survival of F1 oospores, characterized by heterozygosity excess, coupled with a low rate of selfing, delayed declines in heterozygosity due to inbreeding and attainment of equilibrium genotypic frequencies. Large allele and haplotype frequency changes in specific genomic regions accompanied the generational shift, representing putative signatures of selection. Finally, we identified an approximately 1.6 Mb region associated with mating type determination, constituting the first detailed genomic analysis of a mating type region (MTR) in Phytophthora. Segregation patterns in the MTR exhibited tropes of sex-linkage, where maintenance of allele frequency differences between isolates of opposite mating type was associated with elevated heterozygosity despite inbreeding. Characterizing the trajectory of this experimental system provides key insights into the processes driving persistent, sexual pathogen populations. PMID:28348576
Wood, W; Pool, G J; Leck, K; Purvis, D
1996-12-01
Past research has found that recipients agree with majority group positions and resist minority group positions on direct measures of influence. The authors suggest that these attitude shifts reflect normative pressures to align with valued majorities and to differentiate from derogated minorities. In support of this idea, participants who considered a majority group relevant to their own self-definitions (but not those who judged it irrelevant), on learning that the group held a counterattitudinal position, shifted their attitudes to agree with the source. In a second study, recipients who judged a minority group (negatively) self-relevant, on learning that the group held a similar attitude to their own, shifted their attitudes to diverge from the source. These shifts in attitudes were based on participants' interpretations of the attitude issues.
Nakao, Takashi; Matsumoto, Tomoya; Morita, Machiko; Shimizu, Daisuke; Yoshimura, Shinpei; Northoff, Georg; Morinobu, Shigeru; Okamoto, Yasumasa; Yamawaki, Shigeto
2013-01-01
Early life stress (ELS), an important risk factor for psychopathology in mental disorders, is associated neuronally with decreased functional connectivity within the default mode network (DMN) in the resting state. Moreover, it is linked with greater deactivation in DMN during a working memory task. Although DMN shows large amplitudes of very low-frequency oscillations (VLFO) and strong involvement during self-oriented tasks, these features’ relation to ELS remains unclear. Therefore, our preliminary study investigated the relationship between ELS and the degree of frontal activations during a resting state and self-oriented task using near-infrared spectroscopy (NIRS). From 22 healthy participants, regional hemodynamic changes in 43 front-temporal channels were recorded during 5 min resting states, and execution of a self-oriented task (color-preference judgment) and a control task (color-similarity judgment). Using a child abuse and trauma scale, ELS was quantified. We observed that ELS showed a negative correlation with medial prefrontal cortex (MPFC) activation during both resting state and color-preference judgment. In contrast, no significant correlation was found between ELS and MPFC activation during color-similarity judgment. Additionally, we observed that ELS and the MPFC activation during color-preference judgment were associated behaviorally with the rate of similar color choice in preference judgment, which suggests that, for participants with higher ELS, decisions in the color-preference judgment were based on an external criterion (color similarity) rather than an internal criterion (subjective preference). Taken together, our neuronal and behavioral findings show that high ELS is related to lower MPFC activation during both rest and self-oriented tasks. This is behaviorally manifest in an abnormal shift from internally to externally guided decision making, even under circumstances where internal guidance is required. PMID:23840186
Self-Transcendence, Sexual Desire, and Sexual Frequency.
Costa, Rui Miguel; Pestana, José; Costa, David
2018-01-02
Self-forgetfulness is a facet of self-transcendence characterized by tendency to experience altered states of consciousness. We examined associations of self-forgetfulness with sexual desire and frequency. Two hundred sixty-one Portuguese men and women completed the self-forgetfulness subscale of the Temperament and Character Inventory-Revised, a measure of openness to experience, and a questionnaire on desired and actual frequency of vaginal intercourse, noncoital sex, and masturbation in the past month. In simple and partial correlations controlling for openness to experience and relationship status, women's self-forgetfulness correlated with desired frequency of intercourse and noncoital sex. For men, self-forgetfulness correlated with actual frequency of intercourse and noncoital sex.
Shifts in fisheries management: adapting to regime shifts
King, Jacquelynne R.; McFarlane, Gordon A.; Punt, André E.
2015-01-01
For many years, fisheries management was based on optimizing yield and maintaining a target biomass, with little regard given to low-frequency environmental forcing. However, this policy was often unsuccessful. In the last two to three decades, fisheries science and management have undergone a shift towards balancing sustainable yield with conservation, with the goal of including ecosystem considerations in decision-making frameworks. Scientific understanding of low-frequency climate–ocean variability, which is manifested as ecosystem regime shifts and states, has led to attempts to incorporate these shifts and states into fisheries assessment and management. To date, operationalizing these attempts to provide tactical advice has met with limited success. We review efforts to incorporate regime shifts and states into the assessment and management of fisheries resources, propose directions for future investigation and outline a potential framework to include regime shifts and changes in ecosystem states into fisheries management.
Davy, Jonathan; Göbel, Matthias
2013-01-01
This study compared the effects of a 1 h self-selected recovery period to those of a standard night shift arrangement (with a total break time of 1-h) over a simulated three-day night shift schedule in a laboratory setting. Results showed that the inclusion of the flexible nap scheme resulted in higher performance output, improvements in physiological strain responses and reduced sleepiness during each night shift and generally over the three-night cycle. Certain variables also revealed the impact of napping compared with the standard rest break condition on the circadian rhythm. The sleep diary records show that the inclusion of the current intervention did not significantly reduce daytime recovery sleep. The results suggest that the potential benefits of flexible napping may outweigh the logistical effort it requires in a workplace environment. Consensus on appropriate napping strategies for shift work remains a challenge. This simulated night shift laboratory study sought to determine the effects of a 1-h self-selected nap opportunity relative to a normal shift set-up. The nap improved performance and decreased sleepiness, without affecting daytime sleep.
Accurate formulas for interaction force and energy in frequency modulation force spectroscopy
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2004-03-01
Frequency modulation atomic force microscopy utilizes the change in resonant frequency of a cantilever to detect variations in the interaction force between cantilever tip and sample. While a simple relation exists enabling the frequency shift to be determined for a given force law, the required complementary inverse relation does not exist for arbitrary oscillation amplitudes of the cantilever. In this letter we address this problem and present simple yet accurate formulas that enable the interaction force and energy to be determined directly from the measured frequency shift. These formulas are valid for any oscillation amplitude and interaction force, and are therefore of widespread applicability in frequency modulation dynamic force spectroscopy.
Upadhyay, Ganesh; Devi, Th Gomti; Singh, Ranjan K; Singh, A; Alapati, P R
2013-05-15
The isotropic and anisotropic Raman peak frequencies of S=O stretching mode of Dimethyl sulfoxide (DMSO) have been discussed in different chemical and isotopic solvent molecules using different mechanisms. The shifting of peak frequency in further dilution of DMSO with solvent molecule is observed for all solvents. Transition dipole - transition dipole interaction and hydrogen bonding may play a major role in shifting of peak frequencies. The non-coincidence effect (NCE) of DMSO was determined for all the solvents and compared with four theoretical models such as McHale's model, Mirone's modification of McHale's model, Logan's model and Onsager-Fröhlich dielectric continuum model respectively. Most of the theoretical models are largely consistent with our experimental data. Copyright © 2013. Published by Elsevier B.V.
Charge-state dynamics in electrostatic force spectroscopy
NASA Astrophysics Data System (ADS)
Ondráček, Martin; Hapala, Prokop; Jelínek, Pavel
2016-07-01
We present a numerical model that allows us to study the response of an oscillating probe in electrostatic force spectroscopy to charge switching in quantum dots at various time scales. The model provides more insight into the behavior of frequency shift and dissipated energy under different scanning conditions when measuring a temporarily charged quantum dot on a surface. Namely, we analyze the dependence of the frequency shift, the dissipated energy, and their fluctuations on the resonance frequency of the tip and on the electron tunneling rates across the tip-quantum dot and quantum dot-sample junctions. We discuss two complementary approaches to simulating the charge dynamics, a stochastic and a deterministic one. In addition, we derive analytic formulas valid for small amplitudes, describing relations between the frequency shift, dissipated energy, and the characteristic rates driving the charging and discharging processes.
Performance Investigation of Millimeter Wave Generation Reliant on Stimulated Brillouin Scattering
NASA Astrophysics Data System (ADS)
Tickoo, Sheetal; Gupta, Amit
2018-04-01
In this work, photonic method of generating the millimeter waves has been done based on Brillouin scattering effect in optical fiber. Here different approaches are proposed to get maximum frequency shift in mm-wave region using only pumps, radio signals with Mach-Zehnder modulator. Moreover for generated signal validation, signals modulated and send to both wired and wireless medium in optical domain. It is observed that maximum shift of 300 GHz is realized using 60 GHz input sine wave. Basically a frequency doubler is proposed which double shift of input frequency and provide better SNR. For the future generation network system, the generation of millimeter waves makes them well reliable for the transmission of the data.
Waves and instabilities in an anisotropic universe
NASA Astrophysics Data System (ADS)
Papadopoulos, D.; Vlahos, L.; Esposito, F. P.
2002-01-01
The excitation of low frequency plasma waves in an expanding anisotropic cosmological model that contains a magnetic field frozen into the matter and pointing in the longitudinal direction is discussed. Using the exact equations governing finite-amplitude wave propagation in hydromagnetic media within the framework of the general theory of relativity, we show that a spectrum of magnetized sound waves will be excited and form large-scale ``damped oscillations'' in the expanding universe. The characteristic frequency of the excited waves is slightly shifted away from the sound frequency and the shift depends on the strength of the primordial magnetic field. This magnetic field dependent shift may have an effect on the acoustic peaks of the CMB.
Salicylate-induced changes in auditory thresholds of adolescent and adult rats.
Brennan, J F; Brown, C A; Jastreboff, P J
1996-01-01
Shifts in auditory intensity thresholds after salicylate administration were examined in postweanling and adult pigmented rats at frequencies ranging from 1 to 35 kHz. A total of 132 subjects from both age levels were tested under two-way active avoidance or one-way active avoidance paradigms. Estimated thresholds were inferred from behavioral responses to presentations of descending and ascending series of intensities for each test frequency value. Reliable threshold estimates were found under both avoidance conditioning methods, and compared to controls, subjects at both age levels showed threshold shifts at selective higher frequency values after salicylate injection, and the extent of shifts was related to salicylate dose level.
Comments on Landau damping due to synchrotron frequency spread
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, K.Y.; /Fermilab
2005-01-01
An inductive/space-charge impedance shifts the synchrotron frequency downwards above/below transition, but it is often said that the coherent synchrotron frequency of the bunch is not shifted in the rigid-dipole mode. On the other hand, the incoherent synchrotron frequency due to the sinusoidal rf always spreads in the downward direction. This spread will therefore not be able to cover the coherent synchrotron frequency, implying that there will not be any Landau damping no matter how large the frequency spread is. By studying the dispersion relation, it is shown that the above argument is incorrect, and there will be Landau damping ifmore » there is sufficient frequency spread. The main reason is that the coherent frequency of the rigid-dipole mode will no longer remain unshifted in the presence of a synchrotron frequency spread.« less
Petlevich, Walter J.; Sverdrup, Edward F.
1978-01-01
A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.
Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor.
You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen
2017-03-31
The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face.
Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor
You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen
2017-01-01
The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face. PMID:28362349
On the role of mean flows in Doppler shifted frequencies
NASA Astrophysics Data System (ADS)
Gerkema, Theo; Maas, Leo R. M.; van Haren, Hans
2013-04-01
In the oceanographic literature, the term 'Doppler shift' often features in the context of mean flows and (internal) waves. Closer inspection reveals that the term is in fact used for two different things, which should be carefully distinguished, for their conflation results in incorrect interpretations. One refers to the difference in frequencies measured by two observers, one at a fixed position and one moving with the mean flow. The other definition is the one used in physics, where the frequency measured by an observer is compared to that of the source. In the latter sense, Doppler shifts occur only if the source and observer move with respect to each other; a steady mean flow cannot create a Doppler shift. We rehash the classical theory to straighten out some misconceptions and discuss how wave dispersion affects the classical relations and their application, for example on near-inertial internal waves.
NASA Astrophysics Data System (ADS)
Wan, Yuhong; Man, Tianlong; Wu, Fan; Kim, Myung K.; Wang, Dayong
2016-11-01
We present a new self-interference digital holographic approach that allows single-shot capturing three-dimensional intensity distribution of the spatially incoherent objects. The Fresnel incoherent correlation holographic microscopy is combined with parallel phase-shifting technique to instantaneously obtain spatially multiplexed phase-shifting holograms. The compressive-sensing-based reconstruction algorithm is implemented to reconstruct the original object from the under sampled demultiplexed holograms. The scheme is verified with simulations. The validity of the proposed method is experimentally demonstrated in an indirectly way by simulating the use of specific parallel phase-shifting recording device.
Investigation of BOLD fMRI Resonance Frequency Shifts and Quantitative Susceptibility Changes at 7 T
Bianciardi, Marta; van Gelderen, Peter; Duyn, Jeff H.
2013-01-01
Although blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments of brain activity generally rely on the magnitude of the signal, they also provide frequency information that can be derived from the phase of the signal. However, because of confounding effects of instrumental and physiological origin, BOLD related frequency information is difficult to extract and therefore rarely used. Here, we explored the use of high field (7 T) and dedicated signal processing methods to extract frequency information and use it to quantify and interpret blood oxygenation and blood volume changes. We found that optimized preprocessing improves detection of task-evoked and spontaneous changes in phase signals and resonance frequency shifts over large areas of the cortex with sensitivity comparable to that of magnitude signals. Moreover, our results suggest the feasibility of mapping BOLD quantitative susceptibility changes in at least part of the activated area and its largest draining veins. Comparison with magnitude data suggests that the observed susceptibility changes originate from neuronal activity through induced blood volume and oxygenation changes in pial and intracortical veins. Further, from frequency shifts and susceptibility values, we estimated that, relative to baseline, the fractional oxygen saturation in large vessels increased by 0.02–0.05 during stimulation, which is consistent to previously published estimates. Together, these findings demonstrate that valuable information can be derived from fMRI imaging of BOLD frequency shifts and quantitative susceptibility changes. PMID:23897623
Viscoelasticity of new generation thermoplastic polyurethane vibration isolators
NASA Astrophysics Data System (ADS)
Bek, Marko; Betjes, Joris; von Bernstorff, Bernd-Steffen; Emri, Igor
2017-12-01
This paper presents the analysis of pressure dependence of three thermoplastic polyurethane (TPU) materials on vibration isolation. The three TPU Elastollan® materials are 1190A, 1175A, and 1195D. The aim of this investigation was to analyze how much the performance of isolation can be enhanced using patented Dissipative bulk and granular systems technology. The technology uses granular polymeric materials to enhance materials properties (without changing its chemical or molecular composition) by exposing them to "self-pressurization," which shifts material energy absorption maxima toward lower frequencies, to match the excitation frequency of dynamic loading to which a mechanical system is exposed. Relaxation experiments on materials were performed at different isobaric and isothermal states to construct mastercurves, the time-temperature-pressure interrelation was modeled using the Fillers-Moonan-Tschoegl model. Dynamic material functions, related to isolation stiffness and energy absorption, were determined with the Schwarzl approximation. An increase in stiffness and energy absorption at selected hydrostatic pressure, compared to its stiffness and energy absorption at ambient conditions, is represented with κk(p, ω), defining the increase in stiffness and κd(p, ω), defining the increase in energy absorption. The study showed that close to the glassy state, moduli of 1190A and 1195D are about 6-9 times higher compared to 1175A, whereas their properties at ambient conditions are, for all practical purposes, the same. TPU 1190A turns out to be most sensitive to pressure: at 300 MPa its properties are shifted for 5.5 decades, while for 1195D and 1175A this shift is only 3.5 and 1.5 decades, respectively. In conclusion, the stiffness and energy absorption of isolation may be increased with pressure for about 100 times for 1190A and 1195D and for about 10 times for 1175A.
Miller, Brian S.; Leaper, Russell; Calderan, Susannah; Gedamke, Jason
2014-01-01
The song of Antarctic blue whales (Balaenoptera musculus intermedia) comprises repeated, stereotyped, low-frequency calls. Measurements of these calls from recordings spanning many years have revealed a long-term linear decline as well as an intra-annual pattern in tonal frequency. While a number of hypotheses for this long-term decline have been investigated, including changes in population structure, changes in the physical environment, and changes in the behaviour of the whales, there have been relatively few attempts to explain the intra-annual pattern. An additional hypothesis that has not yet been investigated is that differences in the observed frequency from each call are due to the Doppler effect. The assumptions and implications of the Doppler effect on whale song are investigated using 1) vessel-based acoustic recordings of Antarctic blue whales with simultaneous observation of whale movement and 2) long-term acoustic recordings from both the subtropics and Antarctic. Results from vessel-based recordings of Antarctic blue whales indicate that variation in peak-frequency between calls produced by an individual whale was greater than would be expected by the movement of the whale alone. Furthermore, analysis of intra-annual frequency shift at Antarctic recording stations indicates that the Doppler effect is unlikely to fully explain the observations of intra-annual pattern in the frequency of Antarctic blue whale song. However, data do show cyclical changes in frequency in conjunction with season, thus suggesting that there might be a relationship among tonal frequency, body condition, and migration to and from Antarctic feeding grounds. PMID:25229644
Miller, Brian S; Leaper, Russell; Calderan, Susannah; Gedamke, Jason
2014-01-01
The song of Antarctic blue whales (Balaenoptera musculus intermedia) comprises repeated, stereotyped, low-frequency calls. Measurements of these calls from recordings spanning many years have revealed a long-term linear decline as well as an intra-annual pattern in tonal frequency. While a number of hypotheses for this long-term decline have been investigated, including changes in population structure, changes in the physical environment, and changes in the behaviour of the whales, there have been relatively few attempts to explain the intra-annual pattern. An additional hypothesis that has not yet been investigated is that differences in the observed frequency from each call are due to the Doppler effect. The assumptions and implications of the Doppler effect on whale song are investigated using 1) vessel-based acoustic recordings of Antarctic blue whales with simultaneous observation of whale movement and 2) long-term acoustic recordings from both the subtropics and Antarctic. Results from vessel-based recordings of Antarctic blue whales indicate that variation in peak-frequency between calls produced by an individual whale was greater than would be expected by the movement of the whale alone. Furthermore, analysis of intra-annual frequency shift at Antarctic recording stations indicates that the Doppler effect is unlikely to fully explain the observations of intra-annual pattern in the frequency of Antarctic blue whale song. However, data do show cyclical changes in frequency in conjunction with season, thus suggesting that there might be a relationship among tonal frequency, body condition, and migration to and from Antarctic feeding grounds.
Effects of Frequency Drift on the Quantification of Gamma-Aminobutyric Acid Using MEGA-PRESS
Tsai, Shang-Yueh; Fang, Chun-Hao; Wu, Thai-Yu; Lin, Yi-Ru
2016-01-01
The MEGA-PRESS method is the most common method used to measure γ-aminobutyric acid (GABA) in the brain at 3T. It has been shown that the underestimation of the GABA signal due to B0 drift up to 1.22 Hz/min can be reduced by post-frequency alignment. In this study, we show that the underestimation of GABA can still occur even with post frequency alignment when the B0 drift is up to 3.93 Hz/min. The underestimation can be reduced by applying a frequency shift threshold. A total of 23 subjects were scanned twice to assess the short-term reproducibility, and 14 of them were scanned again after 2–8 weeks to evaluate the long-term reproducibility. A linear regression analysis of the quantified GABA versus the frequency shift showed a negative correlation (P < 0.01). Underestimation of the GABA signal was found. When a frequency shift threshold of 0.125 ppm (15.5 Hz or 1.79 Hz/min) was applied, the linear regression showed no statistically significant difference (P > 0.05). Therefore, a frequency shift threshold at 0.125 ppm (15.5 Hz) can be used to reduce underestimation during GABA quantification. For data with a B0 drift up to 3.93 Hz/min, the coefficients of variance of short-term and long-term reproducibility for the GABA quantification were less than 10% when the frequency threshold was applied. PMID:27079873
Critical review of stress coatings for membrane optics
NASA Astrophysics Data System (ADS)
Morrison, S.; Gavrin, A.; Gonyer, R.; Blizard, K.; Bradshaw, J.; Gunderson, L.; Jenkins, C.
2005-08-01
The need and desire for large-scale reflectors is immediate and long lasting. Therefore engineers and designers are turning toward processes that produce reflectors much different than the conventional ground glass mirror. This paradigm shift encompasses many new and emerging technologies, including, but not limited to, pressure-augmented stress-coated membrane mirrors. Recent research has centered on determining the proper amount of stress (from the coating) to apply to a membrane substrate to produce a near-net shape that can be augmented with positive pressure to conclude in the smallest figure error. The bulge test has been applied to membrane samples of seven inch diameter, both uncoated and after coating, and central displacements used as data points when coupled with the finite element code ABAQUS to determine strain and stress values. These values are then correlated to the coating process to determine a 'coating prescription' by which that state of minimal figure error can be attained. Vibration testing in vacuum also shows promise as an effective method to determine the amount of stress present in the coated membrane. The shifts in natural frequencies of a coated membrane versus its uncoated self are unique and indicative of the stress increase by the addition of the coating. These natural frequencies are input into theoretical and ABAQUS models to determine strain and stress. This method is used to provide confidence with the bulge test results.
From self-organization to emergence: Aesthetic implications of shifting ideas of organization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayles, N.K.
1996-06-01
From 1945{endash}95, a shift took place within cybernetics from a paradigm emphasizing self-organization to one emphasizing emergence. Central in bringing about this shift was the spread of the microcomputer. With its greatly enhanced processing speed and memory capabilities, the microcomputer made simulations possible that could not have been done before. The microcomputer has also been instrumental in effecting a similar change within literary texts. To exemplify the aesthetic implications of the shift from self-organization to emergence, the chapter discusses Vladmir Nabokov{close_quote}s {ital Pale} {ital Fire} and Milorad Pavi{acute c}{close_quote}s {ital Dictionary} {ital of} {ital the} {ital Khazars}: {ital A} {italmore » Lexicon} {ital Novel} {ital in} 100,000 {ital Words}. {copyright} {ital 1996 American Institute of Physics.}« less
Stimulated scattering in Ag nanoparticle colloids
NASA Astrophysics Data System (ADS)
Averyushkin, A. S.; Bulychev, N. A.; Efimkov, V. F.; Erokhin, A. I.; Kazaryan, M. A.; Mikhailov, S. I.; Saraeva, I. N.; Zubarev, I. G.
2017-05-01
A number of features of stimulated thermal Rayleigh scattering (STRS) in pure liquids and nanoparticle solutions are investigated in this work. It is shown that scattering efficiency is not reduced in the case of wide spectral bandwidth pump radiation. It is shown experimentally that the frequency shift of the scattered signal relative to the pump frequency greatly exceeds the theoretical value. It is also shown theoretically that the frequency shift value does not depend on the linewidth of the pump.
Etlinger, S C; Guttmann, G; Bauer, H
1986-07-01
A description of scalp-recorded, spontaneous, cerebral DC-potential shifts is given independent of other variables (shift stereotypy), in relationship to higher frequencies (theta, alpha 1, alpha 2: 4-13 Hz) and as analyzed pairwise across the median sagittal line (Fz, Cz, Pz) separately according to frequency and condition (relaxation and moderate mental load). Spontaneous DC-shifts are shown to behave unpredictably. Whether measured jointly (up to triads) or as dyad and triad context entropy, the frontal DC-shifts are calculated as being random, whereby their definition as such within the context of the Principle Component Analysis is supported by the analysis of longitudinal registrations. Cross-correlation analysis of the cerebral slow potential's relationship to each of the higher frequencies (theta, alpha 1, alpha 2) reveals it to be highly independent, the highest correlation accounting for merely 11% of the common variance, the average being 9% (R congruent to 0.3). By matching the conjoint activity of the DC-potential between Fz-Cz, Cz-Pz, and Fz-Pz to that of theta, alpha 1, alpha 2 at the same paired sites, the DC-activity is shown to be operating at higher levels of synchronous activity than the higher frequencies, regardless of pairing and/or condition, although the general level of synchronous activity (DC, theta, alpha 1, alpha 2) is remarkably high along the median sagittal line, 75% of the correlation averages of all analysis-pairings being above 0.60.
NASA Technical Reports Server (NTRS)
Xiong, Fuqin; Andro, Monty
2001-01-01
This paper first shows that the Doppler frequency shift affects the frequencies of the RF carrier, subcarriers, envelope, and symbol timing by the same percentage in an Orthogonal Frequency Division Multiplexing (OFDM) signal or any other modulated signals. Then the SNR degradation of an OFDM system due to Doppler frequency shift, frequency offset of the local oscillators and phase noise is analyzed. Expressions are given and values for 4-, 16-, 64-, and 256-QAM OFDM systems are calculated and plotted. The calculations show that the Doppler shift of the D3 project is about 305 kHz, and the degradation due to it is about 0.01 to 0.04 dB, which is negligible. The degradation due to frequency offset and phase noise of local oscillators will be the main source of degradation. To keep the SNR degradation under 0.1 dB, the relative frequency offset due to local oscillators must be below 0.01 for the 16 QAM-OFDM. This translates to an offset of 1.55 MHz (0.01 x 155 MHz) or a stability of 77.5 ppm (0.01 x 155 MHz/20 GHz) for the DI project. To keep the SNR degradation under 0.1 dB, the relative linewidth (0) due to phase noise of the local oscillators must be below 0.0004 for the 16 QAM-OFDM. This translates to a linewidth of 0.062 MHz (0.0004 x 155 MHz) of the 20 GHz RIF carrier. For a degradation of 1 dB, beta = 0.04, and the linewidth can be relaxed to 6.2 MHz.
NASA Astrophysics Data System (ADS)
Chen, Ruizhu; Zhao, Junwei
2018-02-01
Time–distance helioseismology measures acoustic travel times to infer the structure and flow field of the solar interior; however, both the mean travel times and the travel-time shifts suffer systematic center-to-limb variations, which complicate the interpretation and inversions of the time–distance measurements. In particular, the center-to-limb variation in travel-time shifts (CtoL effect) has a significant impact on the inference of the Sun’s meridional circulation, and needs to be removed from the helioseismic measurements, although the observational properties and the physical cause of the CtoL effect have yet to be investigated. In this study, we measure the CtoL effect in the frequency domain using Doppler-velocity data from the Solar Dynamics Observatory/Helioseismic and Magnetic Imager, and study its properties as a function of disk-centric distance, travel distance, and frequency of acoustic waves. It is found that the CtoL effect has a significant frequency dependence—it reverses sign at a frequency around 5.4 mHz and reaches maximum at around 4.0 mHz before the sign reversal. The tendency of frequency dependence varies with disk-centric distance in a way that both the sign-reversal frequency and the maximum-value frequency decrease closer to the limb. The variation tendency does not change with travel distance, but the variation magnitude is approximately proportional to travel distance. For comparison, the flow-induced travel-time shifts show little frequency dependence. These observational properties provide more clues on the nature of the CtoL effect, and also possibly lead to new ways of effect-removal for a more robust determination of the deep meridional flow.
Bernstein wave aided laser third harmonic generation in a plasma
NASA Astrophysics Data System (ADS)
Tyagi, Yachna; Tripathi, Deepak; Kumar, Ashok
2016-09-01
The process of Bernstein wave aided resonant third harmonic generation of laser in a magnetized plasma is investigated. The extra-ordinary mode (X-mode) laser of frequency ω 0 and wave number k → 0 , travelling across the magnetic field in a plasma, exerts a second harmonic ponderomotive force on the electrons imparting them an oscillatory velocity v → 2 ω0 , 2 k → 0 . This velocity beats with the density perturbation due to the Bernstein wave to produce a density perturbation at cyclotron frequency shifted second harmonic. The density perturbation couples with the oscillatory velocity v → ω0 , k → 0 of X-mode of the laser to produce the cyclotron frequency shifted third harmonic current density leading to harmonic radiation. The phase matching condition for the up shifted frequency is satisfied when the Bernstein wave is nearly counter-propagating to the laser. As the transverse wave number of the Bernstein wave is large, it is effective in the phase matched third harmonic generation, when the laser frequency is not too far from the upper hybrid frequency.
Neural Correlates of Vocal Production and Motor Control in Human Heschl's Gyrus
Oya, Hiroyuki; Nourski, Kirill V.; Kawasaki, Hiroto; Larson, Charles R.; Brugge, John F.; Howard, Matthew A.; Greenlee, Jeremy D.W.
2016-01-01
The present study investigated how pitch frequency, a perceptually relevant aspect of periodicity in natural human vocalizations, is encoded in Heschl's gyrus (HG), and how this information may be used to influence vocal pitch motor control. We recorded local field potentials from multicontact depth electrodes implanted in HG of 14 neurosurgical epilepsy patients as they vocalized vowel sounds and received brief (200 ms) pitch perturbations at 100 Cents in their auditory feedback. Event-related band power responses to vocalizations showed sustained frequency following responses that tracked voice fundamental frequency (F0) and were significantly enhanced in posteromedial HG during speaking compared with when subjects listened to the playback of their own voice. In addition to frequency following responses, a transient response component within the high gamma frequency band (75–150 Hz) was identified. When this response followed the onset of vocalization, the magnitude of the response was the same for the speaking and playback conditions. In contrast, when this response followed a pitch shift, its magnitude was significantly enhanced during speaking compared with playback. We also observed that, in anterolateral HG, the power of high gamma responses to pitch shifts correlated with the magnitude of compensatory vocal responses. These findings demonstrate a functional parcellation of HG with neural activity that encodes pitch in natural human voice, distinguishes between self-generated and passively heard vocalizations, detects discrepancies between the intended and heard vocalization, and contains information about the resulting behavioral vocal compensations in response to auditory feedback pitch perturbations. SIGNIFICANCE STATEMENT The present study is a significant contribution to our understanding of sensor-motor mechanisms of vocal production and motor control. The findings demonstrate distinct functional parcellation of core and noncore areas within human auditory cortex on Heschl's gyrus that process natural human vocalizations and pitch perturbations in the auditory feedback. In addition, our data provide evidence for distinct roles of high gamma neural oscillations and frequency following responses for processing periodicity in human vocalizations during vocal production and motor control. PMID:26888939
Goodman, Shawn S; Keefe, Douglas H
2006-06-01
Otoacoustic emissions serve as a noninvasive probe of the medial olivocochlear (MOC) reflex. Stimulus frequency otoacoustic emissions (SFOAEs) elicited by a low-level probe tone may be the optimal type of emission for studying MOC effects because at low levels, the probe itself does not elicit the MOC reflex [Guinan et al. (2003) J. Assoc. Res. Otolaryngol. 4:521]. Based on anatomical considerations, the MOC reflex activated by ipsilateral acoustic stimulation (mediated by the crossed olivocochlear bundle) is predicted to be stronger than the reflex to contralateral stimulation. Broadband noise is an effective activator of the MOC reflex; however, it is also an effective activator of the middle-ear muscle (MEM) reflex, which can make results difficult to interpret. The MEM reflex may be activated at lower levels than measured clinically, and most previous human studies have not explicitly included measurements to rule out MEM reflex contamination. The current study addressed these issues using a higher-frequency SFOAE probe tone to test for cochlear changes mediated by the MOC reflex, while simultaneously monitoring the MEM reflex using a low-frequency probe tone. Broadband notched noise was presented ipsilaterally at various levels to elicit probe-tone shifts. Measurements are reported for 15 normal-hearing subjects. With the higher-frequency probe near 1.5 kHz, only 20% of subjects showed shifts consistent with an MOC reflex in the absence of an MEM-induced shift. With the higher-frequency probe near 3.5 kHz, up to 40% of subjects showed shifts in the absence of an MEM-induced shift. However, these responses had longer time courses than expected for MOC-induced shifts, and may have been dominated by other cochlear processes, rather than MOC reflex. These results suggest caution in the interpretation of effects observed using ipsilaterally presented acoustic activators intended to excite the MOC reflex.
Raman scattering of Cisplatin near silver nanoparticles
NASA Astrophysics Data System (ADS)
Mirsaleh-Kohan, Nasrin; Duplanty, Michael; Torres, Marjorie; Moazzezi, Mojtaba; Rostovtsev, Yuri V.
2018-03-01
The Raman scattering of Cisplatin (the first generation of anticancer drugs) has been studied. In the presence of silver nanoparticles, strong modifications of Raman spectra have been observed. The Raman frequencies have been shifted and the line profiles are broadened. We develop a theoretical model to explain the observed features of the Raman scattering. The model takes into account self-consistently the interaction of molecules with surface plasmonic waves excited in the silver nanoparticles, and it provides a qualitative agreement with the observed Raman spectra. We have demonstrated that the using silver nanoparticles can increase sensitivity of the technique, and potentially it has a broader range of applications to both spectroscopy and microscopy.
High power impulse magnetron sputtering discharges: Instabilities and plasma self-organization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehiasarian, A. P.; New, R.; Hecimovic, A.
We report on instabilities in high power impulse magnetron sputtering plasmas which are likely to be of the generalized drift wave type. They are characterized by well defined regions of high and low plasma emissivity along the racetrack of the magnetron and cause periodic shifts in floating potential. The azimuthal mode number m depends on plasma current, plasma density, and gas pressure. The structures rotate in E-vectorxB-vector direction at velocities of {approx}10 km s{sup -1} and frequencies up to 200 kHz. Collisions with residual gas atoms slow down the rotating wave, whereas increasing ionization degree of the gas and plasmamore » conductivity speeds it up.« less
NASA Astrophysics Data System (ADS)
Rabinovich, Emmanuel M.
2004-05-01
We present an overview of research, conducted and published by the author and colleagues during the preceding decade, with self-oscillating dynamic systems. Special attention has been addressed to sensor type applications that allow one to design a new type of sensors of different physical parameters as well as using system for chemical and biosensors. Many detection methods exploit self-oscillating systems, such as lasers and RF or microwave oscillators, and use changes introduced into a feedback mechanism (for instance laser inter-cavity spectroscopy) for evaluation of different physical parameters such as refractive indices or absorption coefficients. Typically, that approach is very efficient, is easy to implement, and gives high sensitivity. We have demonstrated that a similar method can be used in the case of an RF optoelectronic self-oscillating system (OSOS) with a fiber-optic feedback line. Using fiber as an element of a positive feedback line allows one to design a new family of fiber-optic sensors each of which can be integrated into a fiber-optic feedback line. Changes introduced into the feedback line of an OSOS typically cause an RF frequency shift that can be measured very precisely with an RF frequency counter or spectrum analyzer. For some types of sensors an OSOS can easily incorporate and utilize advantages of well-developed modern inexpensive light sources (VCSELs, LEDs) and opto-electronic components that have been designed for communication purposes. A single closed loop OSOS can be easily duplicated for sensor array measurement via the use of parallel fiber-optics (for example VCSEL arrays and fiber ribbon cables) that have been well developed for telecommunication systems.
Soil-geomorphic heterogeneity governs patchy vegetation dynamics at an arid ecotone.
Bestelmeyer, Brandon T; Ward, Judy P; Havstad, Kris M
2006-04-01
Soil properties are well known to affect vegetation, but the role of soil heterogeneity in the patterning of vegetation dynamics is poorly documented. We asked whether the location of an ecotone separating grass-dominated and sparsely vegetated areas reflected only historical variation in degradation or was related to variation in inherent soil properties. We then asked whether changes in the cover and spatial organization of vegetated and bare patches assessed using repeat aerial photography reflected self-organizing dynamics unrelated to soil variation or the stable patterning of soil variation. We found that the present-day ecotone was related to a shift from more weakly to more strongly developed soils. Parts of the ecotone were stable over a 60-year period, but shifts between bare and vegetated states, as well as persistently vegetated and bare states, occurred largely in small (<40 m2) patches throughout the study area. The probability that patches were presently vegetated or bare, as well as the probability that vegetation persisted and/or established over the 60-year period, was negatively related to surface calcium carbonate and positively related to subsurface clay content. Thus, only a fraction of the landscape was susceptible to vegetation change, and the sparsely vegetated area probably featured a higher frequency of susceptible soil patches. Patch dynamics and self-organizing processes can be constrained by subtle (and often unrecognized) soil heterogeneity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baeßler, S.; Nesvizhevsky, V. V.; Pignol, G.
Quantum states of ultracold neutrons in a gravitational field are characterized through gravitational resonance spectroscopy. This paper discusses systematic effects that appear in the spectroscopic measurements. The discussed frequency shifts-which we call the Stern-Gerlach shift, interference shift, and spectator-state shift-appear in conceivable measurement schemes and have general importance. Lastly, these shifts have to be taken into account in precision experiments.
NASA Astrophysics Data System (ADS)
Zhu, Zihang; Zhao, Shanghong; Li, Xuan; Qu, Kun; Lin, Tao
2018-01-01
A photonic approach to generate frequency-doubled microwave waveforms using an integrated dual-polarization quadrature phase shift keying (DP-QPSK) modulator driven by a sinusoidal radio frequency (RF) signal is proposed. By adjusting the dc bias points of the DP-QPSK modulator, the obtained second-order and six-order harmonics are in phase while the fourth-order harmonics are complementary when the orthogonal polarized outputs of the modulator are photodetected. After properly setting the modulation indices of the modulator, the amplitude of the second-order harmonic is 9 times of that of the six-order harmonic, indicating a frequency-doubled triangular waveform is generated. If a broadband 90° microwave phase shifter is attached after the photodetector (PD) to introduce a 90° phase shift, a frequency-doubled square waveform can be obtained after adjusting the amplitude of the second-order harmonic 3 times of that of the six-order harmonic. The proposal is first theoretically analyzed and then validated by simulation. Simulation results show that a 10 GHz triangular and square waveform sequences are successfully generated from a 5 GHz sinusoidal RF drive signal.
Gmeindl, Leon; Chiu, Yu-Chin; Esterman, Michael S; Greenberg, Adam S; Courtney, Susan M; Yantis, Steven
2016-10-01
The neural substrates of volition have long tantalized philosophers and scientists. Over the past few decades, researchers have employed increasingly sophisticated technology to investigate this issue, but many studies have been limited considerably by their reliance on intrusive experimental procedures (e.g., abrupt instructional cues), measures of brain activity contaminated by overt behavior, or introspective self-report techniques of questionable validity. Here, we used multivoxel pattern time-course analysis of functional magnetic resonance imaging data to index voluntary, covert perceptual acts-shifts of visuospatial attention-in the absence of instructional cues, overt behavioral indices, and self-report. We found that these self-generated, voluntary attention shifts were time-locked to activity in the medial superior parietal lobule, supporting the hypothesis that this brain region is engaged in voluntary attentional reconfiguration. Self-generated attention shifts were also time-locked to activity in the basal ganglia, a novel finding that motivates further research into the role of the basal ganglia in acts of volition. Remarkably, prior to self-generated shifts of attention, we observed early and selective increases in the activation of medial frontal (dorsal anterior cingulate) and lateral prefrontal (right middle frontal gyrus) cortex-activity that likely reflects processing related to the intention or preparation to reorient attention. These findings, which extend recent evidence on freely chosen motor movements, suggest that dorsal anterior cingulate and lateral prefrontal cortices play key roles in both overt and covert acts of volition, and may constitute core components of a brain network underlying the will to attend.
Tracking the Will to Attend: Cortical Activity Indexes Self-Generated, Voluntary Shifts of Attention
Gmeindl, Leon; Chiu, Yu-Chin; Esterman, Michael S.; Greenberg, Adam S.; Courtney, Susan M.; Yantis, Steven
2016-01-01
The neural substrates of volition have long tantalized philosophers and scientists. Over the past few decades, researchers have employed increasingly sophisticated technology to investigate this issue, but many studies have been limited considerably by their reliance on intrusive experimental procedures (e.g., abrupt instructional cues), measures of brain activity contaminated by overt behavior, or introspective self-report techniques of questionable validity. Here, we used multivoxel-pattern time-course analysis of functional magnetic resonance imaging data to index voluntary, covert perceptual acts—shifts of visuospatial attention—in the absence of instructional cues, overt behavioral indices, and self-report. We found that these self-generated, voluntary attention shifts were time-locked to activity in the medial superior parietal lobule, supporting the hypothesis that this brain region is engaged in voluntary attentional reconfiguration. Self-generated attention shifts were also time-locked to activity in the basal ganglia, a novel finding that motivates further research into the role of the basal ganglia in acts of volition. Remarkably, prior to self-generated shifts of attention we observed early and selective increases in activation of medial frontal (dorsal anterior cingulate) and lateral prefrontal cortex (right middle frontal gyrus)—activity that likely reflects processing related to the intention or preparation to reorient attention. These findings, which extend recent evidence on freely chosen motor movements, suggest that dorsal anterior cingulate and lateral prefrontal cortices play key roles in both overt and covert acts of volition, and may constitute core components of a brain network underlying the will to attend. PMID:27301353
NASA Technical Reports Server (NTRS)
Hazra, Rajeeb; Viles, Charles L.; Park, Stephen K.; Reichenbach, Stephen E.; Sieracki, Michael E.
1992-01-01
Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.
Inertial mass sensing with low Q-factor vibrating microcantilevers
NASA Astrophysics Data System (ADS)
Adhikari, S.
2017-10-01
Mass sensing using micromechanical cantilever oscillators has been established as a promising approach. The scientific principle underpinning this technique is the shift in the resonance frequency caused by the additional mass in the dynamic system. This approach relies on the fact that the Q-factor of the underlying oscillator is high enough so that it does not significantly affect the resonance frequencies. We consider the case when the Q-factor is low to the extent that the effect of damping is prominent. It is shown that the mass sensing can be achieved using a shift in the damping factor. We prove that the shift in the damping factor is of the same order as that of the resonance frequency. Based on this crucial observation, three new approaches have been proposed, namely, (a) mass sensing using frequency shifts in the complex plane, (b) mass sensing from damped free vibration response in the time domain, and (c) mass sensing from the steady-state response in the frequency domain. Explicit closed-form expressions relating absorbed mass with changes in the measured dynamic properties have been derived. The rationale behind each new method has been explained using non-dimensional graphical illustrations. The new mass sensing approaches using damped dynamic characteristics can expand the current horizon of micromechanical sensing by incorporating a wide range of additional measurements.
NASA Astrophysics Data System (ADS)
Asemi, H. R.; Asemi, S. R.; Farajpour, A.; Mohammadi, M.
2015-04-01
The potential applications of piezoelectric nanofilms (PNFs) and double-piezoelectric-nanofilm (DPNF) systems as nanoelectromechanical mass sensors are examined. The PNFs carrying multiple nanoparticles at arbitrary locations are modeled as rectangular nonlocal plates with attached concentrated masses. Using the nonlocal elasticity theory and Hamilton's principle, the differential equations of motion are derived for both PNF-based and DPNF-based nanosensors. The influences of small scale, initial stress and temperature change on the frequency shifts of the nanoelectromechanical sensors are taken into consideration. Explicit expressions are derived for the resonance frequencies of the nanosensors by employing the Galerkin method. The present results show that when the value of nonlocal parameter decreases, the frequency shifts of piezoelectric nanosensors increase. Further, the frequency shifts of DPNF-based mass sensors are always greater than those of PNF-based mass sensors. The present work would be helpful in the design of nanoelectromechanical mass sensors using PNFs.
A method of eliminating hydrogen maser wall shift
NASA Technical Reports Server (NTRS)
Levine, M. W.; Vessot, R. F. C.
1972-01-01
Maser output frequency shift was prevented by storage bulb kept at temperature at which wall shift is zero and effects of bulb size, shape, and surface texture are eliminated. Servo system is shown, along with bidirectional counter.
Hyperfine frequencies of {sup 87}Rb and {sup 133}Cs atoms in Xe gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGuyer, B. H.; Xia, T.; Jau, Y.-Y.
2011-09-15
The microwave resonant frequencies of ground-state {sup 87}Rb and {sup 133}Cs atoms in Xe buffer gas are shown to have a relatively large nonlinear dependence on the Xe pressure, presumably because of RbXe or CsXe van der Waals molecules. The nonlinear shifts for Xe are opposite in sign to the previously measured shifts for Ar and Kr, even though all three gases have negative linear shifts. The Xe data show striking discrepancies with the previous theory for nonlinear shifts. Most of this discrepancy is eliminated by accounting for the spin-rotation interaction, {gamma}N{center_dot}S, in addition to the hyperfine-shift interaction, {delta} Amore » I{center_dot}S, in the molecules. To the limit of our experimental accuracy, the shifts of {sup 87}Rb and {sup 133}Cs in He, Ne, and N{sub 2} were linear with pressure.« less
NASA Astrophysics Data System (ADS)
Zhang, Ruiying; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.
2013-08-01
We propose a method for photoacoustic flow measurement based on the Doppler effect from a flowing homogeneous medium. Excited by spatially modulated laser pulses, the flowing medium induces a Doppler frequency shift in the received photoacoustic signals. The frequency shift is proportional to the component of the flow speed projected onto the acoustic beam axis, and the sign of the shift reflects the flow direction. Unlike conventional flowmetry, this method does not rely on particle heterogeneity in the medium; thus, it can tolerate extremely high particle density. A red-ink phantom flowing in a tube immersed in water was used to validate the method in both the frequency and time domains. The phantom flow immersed in an intralipid solution was also measured.
NASA Astrophysics Data System (ADS)
Liu, Wenliang; Wang, Xiaofeng; Wu, Jizhou; Su, Xingliang; Wang, Shen; Sovkov, Vladimir B.; Ma, Jie; Xiao, Liantuan; Jia, Suotang
2017-08-01
We report on the experimental observation and quantitative determination of the laser-induced frequency shift (LIFS) of the ultracold polar molecules formed by photoassociation (PA). The experiments are performed by detecting a series of double PA spectra with a molecular hyperfine structure, which are induced by two PA lasers with a precise and adjustable frequency reference. We find that the LIFS of the molecular hyperfine levels shows a linear dependence on PA laser intensity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Han-Chun; Ye, Tianyu; Mani, R. G.
2015-02-14
Linear polarization angle, θ, dependent measurements of the microwave radiation-induced oscillatory magnetoresistance, R{sub xx}, in high mobility GaAs/AlGaAs 2D electron devices have shown a θ dependence in the oscillatory amplitude along with magnetic field, frequency, and extrema-dependent phase shifts, θ{sub 0}. Here, we suggest a microwave frequency dependence of θ{sub 0}(f) using an analysis that averages over other smaller contributions, when those contributions are smaller than estimates of the experimental uncertainty.
NASA Astrophysics Data System (ADS)
Brandt, N. N.; Chikishev, A. Yu.; Dolgovskii, V. I.; Lebedenko, S. I.
2007-09-01
The effect of solvent on low-frequency oscillations is studied using an example of the 1,1,2,2-tetrachloroethane (TCE) and 1,1,2,2-tetrabromoethane (TBE) molecules, which exhibit torsional oscillations in the terahertz range. Dimethylsulfoxide (DMSO) and carbon tetrachloride (CTC) are used as solvents. It is demonstrated that a decrease in the concentration of the substance under study in the TBE/CTC, TCE/DMSO, and TCE/CTC mixtures leads to a frequency shift of the low-frequency oscillation. The shift is not observed in the TBE/DMSO mixture but a decrease in the TBE concentration causes significant broadening of the low-frequency line.
ERIC Educational Resources Information Center
Greene, Jeffrey Alan; Azevedo, Roger
2007-01-01
This study examined 148 adolescents' use of self-regulated learning (SRL) processes when learning about the circulatory system using hypermedia. We examined participants' verbal protocols to determine the relationship between SRL processes and qualitative shifts in students' mental models from pretest to posttest. Results indicated that…
THE DIALOGICAL SELF IN PSYCHOANALYSIS.
Muller, Felipe
2016-10-01
This paper describes the shift that appears to be taking place in contemporary psychoanalysis, as reflected among intersubjective approaches, from a monological conception of the self to a dialogical one. The monological self emphasizes the separation between mind, body, and external world, focusing on the representational and descriptive/referential function of language. In contrast, the dialogical self emphasizes practices, the permeable nature of relationships between subjects, and the constitutive function of language. This paper attempts to explain the growing emphasis on the dialogical self, understood from a theoretical, metatheoretical, and technical point of view, using contemporary intersubjective approaches to illustrate this shift. © 2016 The Psychoanalytic Quarterly, Inc.
Cardillo, Marcel; Weston, Peter H; Reynolds, Zoe K M; Olde, Peter M; Mast, Austin R; Lemmon, Emily M; Lemmon, Alan R; Bromham, Lindell
2017-08-01
The frequency of evolutionary biome shifts during diversification has important implications for our ability to explain geographic patterns of plant diversity. Recent studies present several examples of biome shifts, but whether frequencies of biome shifts closely reflect geographic proximity or environmental similarity of biomes remains poorly known. We explore this question by using phylogenomic methods to estimate the phylogeny of Hakea, a diverse Australian genus occupying a wide range of biomes. Model-based estimation of ancestral regions indicates that Hakea began diversifying in the Mediterranean biome of southern Australia in the Middle Eocene-Early Oligocene, and dispersed repeatedly into other biomes across the continent. We infer around 47 shifts between biomes. Frequencies of shifts between pairs of biomes are usually similar to those expected from their geographic connectedness or climatic similarity, but in some cases are substantially higher or lower than expected, perhaps reflecting how readily key physiological traits can be modified to adapt lineages to new environments. The history of frequent biome-shifting is reflected in the structure of present-day assemblages, which tend to be more phylogenetically diverse than null-model expectations. The case of Hakea demonstrates that the radiation of large plant clades across wide geographic areas need not be constrained by dispersal limitation or conserved adaptations to particular environments. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Matrix isolation infrared spectra of hydrogen halide and halogen complexes with nitrosyl halides
NASA Technical Reports Server (NTRS)
Allamandola, Louis J.; Lucas, Donald; Pimentel, George C.
1982-01-01
Matrix isolation infrared spectra of nitrosyl halide (XNO) complexes with HX and X2 (X = Cl, Br) are presented. The relative frequency shifts of the HX mode are modest (ClNO H-Cl, delta-nu/nu = -0.045; BrNO H-Br, delta-nu/nu = -0.026), indicating weak hydrogen bonds 1-3 kcal/mol. These shifts are accompanied by significant shifts to higher frequencies in the XN-O stretching mode (CIN-O HCl, delta-nu/nu = +0.016; BrN-O HBr, delta-nu/nu = +0.011). Similar shifts were observed for the XN-O X2 complexes (ClN-O Cl2, delta-nu/nu = +0.009; BrN-O-Br2, delta-nu/nu = +0.013). In all four complexes, the X-NO stretching mode relative shift is opposite in sign and about 1.6 times that of the NO stretching mode. These four complexes are considered to be similar in structure and charge distribution. The XN-O frequency shift suggests that complex formation is accompanied by charge withdrawal from the NO bond ranging from about .04 to .07 electron charges. The HX and X2 molecules act as electron acceptors, drawing electrons out of the antibonding orbital of NO and strengthening the XN-O bond. The implications of the pattern of vibrational shifts concerning the structure of the complexes are discussed.
Pneumatic oscillator circuits for timing and control of integrated microfluidics.
Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E
2013-11-05
Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.
Chen, Yu; Mu, Xiaojing; Wang, Tao; Ren, Weiwei; Yang, Ya; Wang, Zhong Lin; Sun, Chengliang; Gu, Alex Yuandong
2016-01-01
Here, we report a stable and predictable aero-elastic motion in the flow-driven energy harvester, which is different from flapping and vortex-induced-vibration (VIV). A unified theoretical frame work that describes the flutter phenomenon observed in both “stiff” and “flexible” materials for flow driven energy harvester was presented in this work. We prove flutter in both types of materials is the results of the coupled effects of torsional and bending modes. Compared to “stiff” materials, which has a flow velocity-independent flutter frequency, flexible material presents a flutter frequency that almost linearly scales with the flow velocity. Specific to “flexible” materials, pre-stress modulates the frequency range in which flutter occurs. It is experimentally observed that a double-clamped “flexible” piezoelectric P(VDF-TrFE) thin belt, when driven into the flutter state, yields a 1,000 times increase in the output voltage compared to that of the non-fluttered state. At a fixed flow velocity, increase in pre-stress level of the P(VDF-TrFE) thin belt up-shifts the flutter frequency. In addition, this work allows the rational design of flexible piezoelectric devices, including flow-driven energy harvester, triboelectric energy harvester, and self-powered wireless flow speed sensor. PMID:27739484
The effect of combination of magnetic field and low temperature on doped quantum wells
NASA Astrophysics Data System (ADS)
de P. Abreu, E.; Serra, R. M.; Emmel, P. D.
2001-10-01
In this work, we study in the optical absorption of lightly doped and compensated GaAs-GaAlAs quantum wells in the presence of applied magnetic field at low temperatures. The maximum values of magnetic field and temperature are chosen to be 10 T and 5 K, respectively. The wave functions and energies of electrons bound to impurities are calculated variationally using hydrogen-like functions. The absorption coefficient is computed through the use of Fermi golden rule and the statistics of this system is made by a self-consistent calculation of the electrostatic potential generated by ionized impurities, while the convergence parameter is the electronic chemical potential. We focus our attention on 1s→2p ± transitions. The results show that the range of frequency absorbed by the system stays unaltered in 1s→2p - transition and changes for the 1s→2p + transition, presenting a shift to higher frequencies as the magnetic field increases. Another important result is the decrease of the absorption coefficient for the lowest part of the frequency range as the temperature decreases, turning the material almost transparent for those frequencies. This kind of information may be useful for further diagnosis of quantum well systems.
Chen, Yu; Mu, Xiaojing; Wang, Tao; Ren, Weiwei; Yang, Ya; Wang, Zhong Lin; Sun, Chengliang; Gu, Alex Yuandong
2016-10-14
Here, we report a stable and predictable aero-elastic motion in the flow-driven energy harvester, which is different from flapping and vortex-induced-vibration (VIV). A unified theoretical frame work that describes the flutter phenomenon observed in both "stiff" and "flexible" materials for flow driven energy harvester was presented in this work. We prove flutter in both types of materials is the results of the coupled effects of torsional and bending modes. Compared to "stiff" materials, which has a flow velocity-independent flutter frequency, flexible material presents a flutter frequency that almost linearly scales with the flow velocity. Specific to "flexible" materials, pre-stress modulates the frequency range in which flutter occurs. It is experimentally observed that a double-clamped "flexible" piezoelectric P(VDF-TrFE) thin belt, when driven into the flutter state, yields a 1,000 times increase in the output voltage compared to that of the non-fluttered state. At a fixed flow velocity, increase in pre-stress level of the P(VDF-TrFE) thin belt up-shifts the flutter frequency. In addition, this work allows the rational design of flexible piezoelectric devices, including flow-driven energy harvester, triboelectric energy harvester, and self-powered wireless flow speed sensor.
Ju, Jinchuan; Zhang, Jun; Qi, Zumin; Yang, Jianhua; Shu, Ting; Zhang, Jiande; Zhong, Huihuang
2016-01-01
The radio-frequency breakdown due to ultrahigh electric field strength essentially limits power handling capability of an individual high power microwave (HPM) generator, and this issue becomes more challenging for high frequency bands. Coherent power combining therefore provides an alternative approach to achieve an equivalent peak power of the order of ∼100 GW, which consequently provides opportunities to explore microwave related physics at extremes. The triaxial klystron amplifier (TKA) is a promising candidate for coherent power combing in high frequency bands owing to its intrinsic merit of high power capacity, nevertheless phase-locked long pulse radiation from TKA has not yet been obtained experimentally as the coaxial structure of TKA can easily lead to self-excitation of parasitic modes. In this paper, we present investigations into an X-band TKA capable of producing 1.1 GW HPMs with pulse duration of about 103 ns at the frequency of 9.375 GHz in experiment. Furthermore, the shot-to-shot fluctuation standard deviation of the phase shifts between the input and output microwaves is demonstrated to be less than 10°. The reported achievements open up prospects for accomplishing coherent power combining of X-band HPMs in the near future, and might also excite new development interests concerning high frequency TKAs. PMID:27481661
Ju, Jinchuan; Zhang, Jun; Qi, Zumin; Yang, Jianhua; Shu, Ting; Zhang, Jiande; Zhong, Huihuang
2016-08-02
The radio-frequency breakdown due to ultrahigh electric field strength essentially limits power handling capability of an individual high power microwave (HPM) generator, and this issue becomes more challenging for high frequency bands. Coherent power combining therefore provides an alternative approach to achieve an equivalent peak power of the order of ∼100 GW, which consequently provides opportunities to explore microwave related physics at extremes. The triaxial klystron amplifier (TKA) is a promising candidate for coherent power combing in high frequency bands owing to its intrinsic merit of high power capacity, nevertheless phase-locked long pulse radiation from TKA has not yet been obtained experimentally as the coaxial structure of TKA can easily lead to self-excitation of parasitic modes. In this paper, we present investigations into an X-band TKA capable of producing 1.1 GW HPMs with pulse duration of about 103 ns at the frequency of 9.375 GHz in experiment. Furthermore, the shot-to-shot fluctuation standard deviation of the phase shifts between the input and output microwaves is demonstrated to be less than 10°. The reported achievements open up prospects for accomplishing coherent power combining of X-band HPMs in the near future, and might also excite new development interests concerning high frequency TKAs.
Frequency-shift detectors bind binaural as well as monaural frequency representations.
Carcagno, Samuele; Semal, Catherine; Demany, Laurent
2011-12-01
Previous psychophysical work provided evidence for the existence of automatic frequency-shift detectors (FSDs) that establish perceptual links between successive sounds. In this study, we investigated the characteristics of the FSDs with respect to the binaural system. Listeners were presented with sound sequences consisting of a chord of pure tones followed by a single test tone. Two tasks were performed. In the "present/absent" task, the test tone was either identical to one of the chord components or positioned halfway in frequency between two components, and listeners had to discriminate between these two possibilities. In the "up/down" task, the test tone was slightly different in frequency from one of the chord components and listeners had to identify the direction (up or down) of the corresponding shift. When the test tone was a pure tone presented monaurally, either to the same ear as the chord or to the opposite ear, listeners performed the up/down task better than the present/absent task. This paradoxical advantage for directional frequency shifts, providing evidence for FSDs, persisted when the test tone was replaced by a dichotic stimulus consisting of noise but evoking a pitch sensation as a consequence of binaural processing. Performance in the up/down task was similar for the dichotic stimulus and for a monaural narrow-band noise matched in pitch salience to it. Our results indicate that the FSDs are insensitive to sound localization mechanisms and operate on central frequency representations, at or above the level of convergence of the monaural auditory pathways.
Optical fiber sources and transmission controls for multi-Tb/s systems
NASA Astrophysics Data System (ADS)
Nowak, George Adelbert
The accelerating demand for bandwidth capacity in backbone links of terrestrial communications systems is projected to exceed 1Tb/s by 2002. Lightwave carrier frequencies and fused-silica optical fibers provide the natural combination of high passband frequencies and low- loss medium to satisfy this evolving demand for bandwidth capacity. This thesis addresses three key technologies for enabling multi-Tb/s optical fiber communication systems. The first technology is a broadband source based on supercontinuum generation in optical fiber. Using a single modelocked laser with output pulsewidths of 0.5psec pulses, we generate in ~2m of dispersion-shifted fiber more that 200nm of spectral continuum in the vicinity of 1550nm that is flat to better than +/- 0.5 dB over more than 60nm. The short fiber length prevents degradation of timing jitter of the seed pulses and preserves coherence of the continuum by inhibiting environmental perturbations and mapping of random noise from the vicinity of the input pulse across the continuum. Through experiments and simulations, we find that the continuum characteristics result from 3rd order dispersion effects on higher-order soliton compression. We determine optimal fiber properties to provide desired continuum broadness and flatness for given input pulsewidth and energy conditions. The second technology is a novel delay-shifted nonlinear optical loop mirror (DS-NOLM) that performs a transmission control function by serving as an intensity filter and frequency compensator for <5psec soliton transmission systems. A theoretical and experimental study of the DS-NOLM as a transmission control element in a periodically amplified soliton transmission system is presented. We show that DS-NOLMs enable 4ps soliton transmission over 75km of standard dispersion fiber, with 25km spacing between amplifiers, by filtering the dispersive waves and compensating for Raman-induced soliton self-frequency shift. The third technology is all-fiber wavelength conversion employing induced modulational instability. We obtain wavelength conversion over 40nm with a peak conversion efficiency of 28dB using 600mW pump pulses in 720m of high-nonlinearity optical fiber. We show that the high- nonlinearity fiber enhances the phase-matching bandwidth as well as reducing the required fiber lengths and pump powers.
Sveinsdóttir, Herdis
2006-06-01
The aim of this study was to describe and compare the self-assessed quality of sleep, occupational health, working environment, illness experience and job satisfaction among female nurses working different combinations of shifts. Evidence from several studies indicates that there is an association between the disruption of the circadian cycle caused by shift work and adverse health effects. A cross-sectional design was used with a sample of 348 nurses drawn from the registry of the Icelandic Nurses' Association, representing 17% of the workforce of Icelandic nurses. A self-administered questionnaire, measuring occupational health, quality of sleep, the illness experience, job satisfaction and working environment was used. Data were analysed according to type of shift (days only, rotating days/evenings, rotating days/evenings/nights) by use of analysis of variance and chi-square. No difference was found between participants based on type of shift with regard to the illness experience, job satisfaction and quality of sleep. Nurses working rotating day/evening/night shifts reported a longer working day, more stressful environmental risk factors, more strenuous work and that they were less able to control their work-pace. In general, the nurses reported low severity of symptoms; however, nurses working rotating days/evenings shifts experienced more severe gastrointestinal and musculoskeletal symptoms when compared with others. This was explained by the short rest period provided for between evening and morning shifts. In general Icelandic nurses are satisfied with their work and their shift assignment does not seem to pathologically disrupt their circadian cycle. Nevertheless, nursing directors are advised to look more closely at the organization of nurses' work during night shifts, as well as the rest period for nurses changing from evening to day shifts.
Multi-color γ-rays from comb-like electron beams driven by incoherent stacks of laser pulses
NASA Astrophysics Data System (ADS)
Kalmykov, S. Y.; Davoine, X.; Ghebregziabher, I.; Shadwick, B. A.
2017-03-01
Trains of fs-length, GeV-scale electron bunches with controlled energy spacing and a 5-D brightness up to 1017 A/m2 may be produced in a mm-scale uniform plasma. The main element of the scheme is an incoherent stack of 10-TW-scale laser pulses of different colors, with mismatched focal spots, with the highest-frequency pulse advanced in time. While driving an electron density bubble, this stack remains almost proof against nonlinear red-shift and self-compression. As a consequence, the unwanted continuous injection of background electrons is minimized. Weak focusing of the trailing (lower-frequency) component of the stack enforces expansions and contractions of the bubble, inducing controlled periodic injection. The resulting train of electron bunches maintains exceptional quality while being accelerated beyond the energy limits predicted by accepted scalings. Inverse Thomson scattering from this comb-like beam generates a sequence of quasi-monochromatic, fs-length γ-ray beams, an asset for nuclear forensics and pump-probe experiments in dense plasmas.
Mulry, Claire M; Papetti, Christina; De Martinis, Julian; Ravinsky, Mark
Community participation is integral to wellness. This study examined the outcomes of Let's Go, a program designed to facilitate community participation of urban-dwelling, low-income older adults. Fifty-two older adults participated in a mixed-methods, single-group pretest-posttest study. The Impact on Participation and Autonomy Questionnaire, participant surveys, and semistructured interviews were used to evaluate self-reported participation in community-based occupations, confidence, isolation, frequency of community trips, autonomy outdoors, and satisfaction with social life and relationships. Significant improvement was found in participation, confidence, frequency of community trips, autonomy outdoors, and satisfaction with social life and relationships at 4 wk and 6 mo. Qualitative themes were decreased isolation, importance of peer and community support, increased knowledge of mobility options, and a shift from fear to confidence. Community mobility programming can facilitate the participation of marginalized older adults in community-based occupations. Copyright © 2017 by the American Occupational Therapy Association, Inc.
Seismic event classification system
Dowla, F.U.; Jarpe, S.P.; Maurer, W.
1994-12-13
In the computer interpretation of seismic data, the critical first step is to identify the general class of an unknown event. For example, the classification might be: teleseismic, regional, local, vehicular, or noise. Self-organizing neural networks (SONNs) can be used for classifying such events. Both Kohonen and Adaptive Resonance Theory (ART) SONNs are useful for this purpose. Given the detection of a seismic event and the corresponding signal, computation is made of: the time-frequency distribution, its binary representation, and finally a shift-invariant representation, which is the magnitude of the two-dimensional Fourier transform (2-D FFT) of the binary time-frequency distribution. This pre-processed input is fed into the SONNs. These neural networks are able to group events that look similar. The ART SONN has an advantage in classifying the event because the types of cluster groups do not need to be pre-defined. The results from the SONNs together with an expert seismologist's classification are then used to derive event classification probabilities. 21 figures.
Seismic event classification system
Dowla, Farid U.; Jarpe, Stephen P.; Maurer, William
1994-01-01
In the computer interpretation of seismic data, the critical first step is to identify the general class of an unknown event. For example, the classification might be: teleseismic, regional, local, vehicular, or noise. Self-organizing neural networks (SONNs) can be used for classifying such events. Both Kohonen and Adaptive Resonance Theory (ART) SONNs are useful for this purpose. Given the detection of a seismic event and the corresponding signal, computation is made of: the time-frequency distribution, its binary representation, and finally a shift-invariant representation, which is the magnitude of the two-dimensional Fourier transform (2-D FFT) of the binary time-frequency distribution. This pre-processed input is fed into the SONNs. These neural networks are able to group events that look similar. The ART SONN has an advantage in classifying the event because the types of cluster groups do not need to be pre-defined. The results from the SONNs together with an expert seismologist's classification are then used to derive event classification probabilities.
Gabriels, Katleen; Moerenhout, Tania
2018-01-12
Nowadays, digital self-tracking devices offer a plethora of possibilities to both healthy and chronically ill users who want to closely examine their body. This study suggests that self-tracking in a private setting will lead to shifting understandings in professional care. To provide more insight into these shifts, this paper seeks to lay bare the promises and challenges of self-tracking while staying close to the everyday professional experience of the physician. The aim of this study was to (1) offer an analysis of how medical doctors evaluate self-tracking methods in their practice and (2) explore the anticipated shifts that digital self-care will bring about in relation to our findings and those of other studies. A total of 12 in-depth semistructured interviews with general practitioners (GPs) and cardiologists were conducted in Flanders, Belgium, from November 2015 to November 2016. Thematic analysis was applied to examine the transcripts in an iterative process. Four major themes arose in our body of data: (1) the patient as health manager, (2) health obsession and medicalization, (3) information management, and (4) shifting roles of the doctors and impact on the health care organization. Our research findings show a nuanced understanding of the potentials and pitfalls of different forms of self-tracking. The necessity of contextualization of self-tracking data and a professionalization of self-care through digital devices come to the fore as important overarching concepts. This interview study with Belgian doctors examines the potentials and challenges of self-monitoring while focusing on the everyday professional experience of the physician. The dialogue between our dataset and the existing literature affords a fine-grained image of digital self-care and its current meaning in a medical-professional landscape. ©Katleen Gabriels, Tania Moerenhout. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 12.01.2018.
2018-01-01
Background Nowadays, digital self-tracking devices offer a plethora of possibilities to both healthy and chronically ill users who want to closely examine their body. This study suggests that self-tracking in a private setting will lead to shifting understandings in professional care. To provide more insight into these shifts, this paper seeks to lay bare the promises and challenges of self-tracking while staying close to the everyday professional experience of the physician. Objective The aim of this study was to (1) offer an analysis of how medical doctors evaluate self-tracking methods in their practice and (2) explore the anticipated shifts that digital self-care will bring about in relation to our findings and those of other studies. Methods A total of 12 in-depth semistructured interviews with general practitioners (GPs) and cardiologists were conducted in Flanders, Belgium, from November 2015 to November 2016. Thematic analysis was applied to examine the transcripts in an iterative process. Results Four major themes arose in our body of data: (1) the patient as health manager, (2) health obsession and medicalization, (3) information management, and (4) shifting roles of the doctors and impact on the health care organization. Our research findings show a nuanced understanding of the potentials and pitfalls of different forms of self-tracking. The necessity of contextualization of self-tracking data and a professionalization of self-care through digital devices come to the fore as important overarching concepts. Conclusions This interview study with Belgian doctors examines the potentials and challenges of self-monitoring while focusing on the everyday professional experience of the physician. The dialogue between our dataset and the existing literature affords a fine-grained image of digital self-care and its current meaning in a medical-professional landscape. PMID:29330140
Lizama, Natalia; Heyworth, Jane; Thomson, Allyson; Slevin, Terry; Fritschi, Lin
2017-10-01
Recall bias is a potential source of misclassification in case-control studies. Studies have shown that the association between exposure and disease can differ according to participants' beliefs or knowledge about the effect of that exposure on disease. We investigated the association between belief about breast cancer causation and self-reported shift work exposure in a case-control study. Women completed a questionnaire asking whether they believed that shift work caused cancer either before or after reporting their history of shift work. We measured: whether belief modified the association between reported shift work and disease; whether belief was associated with reported shift work exposure; and whether being prompted to recall shift work exposure was associated with an increased likelihood of believing that shift work increased breast cancer risk. There was a significant association between believing shift work increased breast cancer risk and reporting exposure to shift work. Being prompted to recall shift work was not associated with a belief that shift work increased risk. The association between pre-existing belief about breast cancer risk and reported shift work is likely to be due to exposed individuals believing that exposure increases risk, rather than resulting from recall bias. Copyright © 2017 Elsevier Ltd. All rights reserved.
Canessa, Clementina; Iacopelli, Jessica; Pecoraro, Antonio; Spadaro, Giuseppe; Matucci, Andrea; Milito, Cinzia; Vultaggio, Alessandra; Agostini, Carlo; Cinetto, Francesco; Danieli, Maria Giovanna; Gambini, Simona; Marasco, Carolina; Trizzino, Antonino; Vacca, Angelo; De Mattia, Domenico; Martire, Baldassarre; Plebani, Alessandro; Di Gioacchino, Mario; Gatta, Alessia; Finocchi, Andrea; Licciardi, Francesco; Martino, Silvana; De Carli, Marco; Moschese, Viviana; Azzari, Chiara
2017-03-01
In patients with primary antibody deficiencies, subcutaneous administration of IgG (SCIG) replacement is effective, safe, well-tolerated, and can be self-administered at home. A new SCIG replacement at 20% concentration (Hizentra ® ) has been developed and has replaced Vivaglobin ® (SCIG 16%). An observational prospective multi-centric open-label study, with retrospective comparison was conducted in 15 Italian centers, in order to investigate whether and to what extent switching to Hizentra ® would affect frequency of infusions, number of infusion sites, patients' satisfaction, and tolerability in patients previously treated with Vivaglobin ® or intravenous immunoglobulins (IVIG). Any variations of dosage, frequency and duration of the infusions, and of number of infusion sites induced by Hizentra ® with respect to the former treatment were recorded. Practical advantages and disadvantages of Hizentra ® , with respect to the medicinal product formerly used, and the variations in patients' therapy-related satisfaction were monitored by means of the TSQM (Treatment Satisfaction Questionnaire for Medication); number, frequency, and duration of infectious events and adverse effects were recorded. Eighty-two patients switched to Hizentra ® : 19 (23.2%) from IVIG and 63 (76.8%) from Vivaglobin ® . The mean interval between infusions was not affected by the shift (7.0 ± 2.0 days with previous treatment versus 7.1 ± 1.2 during Hizentra ® ). A decrease in the number of infusion sites with Hizentra ® was recorded in 12 out of 56 patients for whom these data were available. At 6 months, 89.7% of patients were satisfied with Hizentra ® ; no difference in terms of effectiveness, side effects, convenience, and global satisfaction was observed. No difference in the incidence of adverse events was reported.
NASA Astrophysics Data System (ADS)
Stomp, Romain-Pierre
This thesis is devoted to the studies of self-assembled InAs quantum dots (QD) by low-temperature Atomic Force Microscopy (AFM) in frequency modulation mode. Several spectroscopic methods are developed to investigate single electron charging from a two-dimensional electron gas (2DEG) to an individual InAs QD. Furthermore, a new technique to measure the absolute tip-sample capacitance is also demonstrated. The main observables are the electrostatic force between the metal-coated AFM tip and sample as well as the sample-induced energy dissipation, and therefore no tunneling current has to be collected at the AFM tip. Measurements were performed by recording simultaneously the shift in the resonant frequency and the Q-factor degradation of the oscillating cantilever either as a function of tip-sample voltage or distance. The signature of single electron charging was detected as an abrupt change in the frequency shift as well as corresponding peaks in the dissipation. The main experimental features in the force agree well with the semi-classical theory of Coulomb blockade by considering the free energy of the system. The observed dissipation peaks can be understood as a back-action effect on the oscillating cantilever beam due to the fluctuation in time of electrons tunneling back and forth between the 2DEG and the QD. It was also possible to extract the absolute value of the tip-sample capacitance, as a consequence of the spectroscopic analysis of the electrostic force as a function of tip-sample distance for different values of the applied voltage. At the same time, the contact potential difference and the residual non-capacitive force could also be determined as a function of tip-sample distance.
Simmons, J M; Ackermann, R F; Gallistel, C R
1998-10-15
Lesions in the medial forebrain bundle rostral to a stimulating electrode have variable effects on the rewarding efficacy of self-stimulation. We attempted to account for this variability by measuring the anatomical and functional effects of electrolytic lesions at the level of the lateral hypothalamus (LH) and by correlating these effects to postlesion changes in threshold pulse frequency (pps) for self-stimulation in the ventral tegmental area (VTA). We implanted True Blue in the VTA and compared cell labeling patterns in forebrain regions of intact and lesioned animals. We also compared stimulation-induced regional [14C]deoxyglucose (DG) accumulation patterns in the forebrains of intact and lesioned animals. As expected, postlesion threshold shifts varied: threshold pps remained the same or decreased in eight animals, increased by small but significant amounts in three rats, and increased substantially in six subjects. Unexpectedly, LH lesions did not anatomically or functionally disconnect all forebrain nuclei from the VTA. Most septal and preoptic regions contained equivalent levels of True Blue label in intact and lesioned animals. In both intact and lesioned groups, VTA stimulation increased metabolic activity in the fundus of the striatum (FS), the nucleus of the diagonal band, and the medial preoptic area. On the other hand, True Blue labeling demonstrated anatomical disconnection of the accumbens, FS, substantia innominata/magnocellular preoptic nucleus (SI/MA), and bed nucleus of the stria terminalis. [14C]DG autoradiography indicated functional disconnection of the lateral preoptic area and SI/MA. Correlations between patterns of True Blue labeling or [14C]deoxyglucose accumulation and postlesion shifts in threshold pulse frequency were weak and generally negative. These direct measures of connectivity concord with the behavioral measures in suggesting a diffuse net-like connection between forebrain nuclei and the VTA.
Biosensing in a microelectrofluidic system using optical whispering-gallery mode spectroscopy
Huang, Lei; Guo, Zhixiong
2011-01-01
Label-free detection of biomolecules using an optical whispering-gallery mode sensor in a microelectrofluidic channel is simulated. Negatively charged bovine serum albumin is considered as the model protein analyte. The analyte transport in aqueous solution is controlled by an externally applied electrical field. The finite element method is employed for solving the equations of the charged species transport, the Poisson equation of electric potential, the equations of conservation of momentum and energy, and the Helmholtz equations of electromagnetic waves. The adsorption process of the protein molecules on the microsensor head surface is monitored by the resonance frequency shifts. Frequency shift caused by temperature variation due to Joule heating is analyzed and found to be negligible. The induced shifts behave in a manner similar to Langmuir-like adsorption kinetics; but the time constant increases due to the presence of the external electrical field. A correlation of the frequency shift, the analyte feed concentration in the solution, and the applied voltage gradient is obtained, in which an excellent linear relationship between the frequency shift and the analyte concentration is revealed. The applied voltage gradient enhances significantly the analyte concentration in the vicinity of the sensor surface; thus, the sensor sensitivity which has a power function of the voltage gradient with exponent 2.85 in the controlled voltage range. Simulated detection of extremely low protein concentration to the pico-molar level is carried out. PMID:22662041
A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp
NASA Astrophysics Data System (ADS)
Tanabe, Takehiko; Akamatsu, Daisuke; Inaba, Hajime; Okubo, Sho; Kobayashi, Takumi; Yasuda, Masami; Hosaka, Kazumoto; Hong, Feng-Lei
2018-06-01
We demonstrate a diode laser system operating at 399 nm that is stabilized to the 6s2 1S0–6s6p 1P1 electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached 1.1 × 10‑11 at an averaging time of τ = 1 s. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the 1S0–1P1 transition in 174Yb was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.
Velocity measurement by vibro-acoustic Doppler.
Nabavizadeh, Alireza; Urban, Matthew W; Kinnick, Randall R; Fatemi, Mostafa
2012-04-01
We describe the theoretical principles of a new Doppler method, which uses the acoustic response of a moving object to a highly localized dynamic radiation force of the ultrasound field to calculate the velocity of the moving object according to Doppler frequency shift. This method, named vibro-acoustic Doppler (VAD), employs two ultrasound beams separated by a slight frequency difference, Δf, transmitting in an X-focal configuration. Both ultrasound beams experience a frequency shift because of the moving objects and their interaction at the joint focal zone produces an acoustic frequency shift occurring around the low-frequency (Δf) acoustic emission signal. The acoustic emission field resulting from the vibration of the moving object is detected and used to calculate its velocity. We report the formula that describes the relation between Doppler frequency shift of the emitted acoustic field and the velocity of the moving object. To verify the theory, we used a string phantom. We also tested our method by measuring fluid velocity in a tube. The results show that the error calculated for both string and fluid velocities is less than 9.1%. Our theory shows that in the worst case, the error is 0.54% for a 25° angle variation for the VAD method compared with an error of -82.6% for a 25° angle variation for a conventional continuous wave Doppler method. An advantage of this method is that, unlike conventional Doppler, it is not sensitive to angles between the ultrasound beams and direction of motion.
When the going gets tough...: Self-motivation is associated with invigoration and fun.
Kazén, Miguel; Kuhl, Julius; Leicht, Eva-Maria
2015-11-01
Personality systems interaction (PSI) theory postulates two executive control modes in volitional action: Self-control and self-regulation (self-motivation). Self-control should deplete energy whereas self-motivation should maintain energy and result in invigoration. There were three groups of participants: Self-control, self-motivation, and pretend, who performed a resource-demanding Stroop-Shift and an anagram task. Performance and energy expenditure were examined in each task. Compared to the other groups, the self-motivation group showed increments in blood glucose throughout the experiment, indicating invigoration, and had better performance on the difficult Stroop-Shift task than the self-control group. Additionally, for the self-motivation group anagram performance correlated with less effort and ease of concentration and was moderated by fun in the task. These results are consonant with the predictions of PSI and self-determination theories. It is concluded that self-control depletes resources whereas self-motivation is associated with invigoration in carrying resource-demanding tasks.
Brunstrom, J M; Roberts, B
2001-07-01
When a partial of a periodic complex is mistuned, its change in pitch is greater than expected. Two experiments examined whether these partial-pitch shifts are related to the computation of global pitch. In experiment 1, stimuli were either harmonic or frequency-shifted (25% of F0) complexes. One partial was mistuned by +/- 4% and played with leading and lagging portions of 500 ms each, relative to the other components (1 s), in both monaural and dichotic contexts. Subjects indicated whether the mistuned partial was higher or lower in pitch when concurrent with the other components. Responses were positively correlated with the direction of mistuning in all conditions. In experiment 2, stimuli from each condition were compared with synchronous equivalents. Subjects matched a pure tone to the pitch of the mistuned partial (component 4). The results showed that partial-pitch shifts are not reduced in size by asynchrony. Similar asynchronies are known to produce a near-exclusion of a mistuned partial from the global-pitch computation. This mismatch indicates that global and partial pitch are derived from different processes. The similarity of the partial-pitch shifts observed for harmonic and frequency-shifted stimuli suggests that they arise from a grouping mechanism that is sensitive to spectral regularity.
Femtogram Mass Biosensor Using Self-Sensing Cantilever for Allergy Check
NASA Astrophysics Data System (ADS)
Sone, Hayato; Ikeuchi, Ayumi; Izumi, Takashi; Okano, Haruki; Hosaka, Sumio
2006-03-01
A self-sensing mass biosensor with a femtogram mass sensitivity has been developed using a piezoresistive microcantilever. The mass change due to antigen and antibody adsorption on the cantilever in water was detected by the resonance frequency shift of the cantilever. We constructed a prototype harmonic vibration sensor using a commercial piezoresistive cantilever, Wheatstone bridge circuits, a positive feedback controller, an exciting piezoactuator and a phase-locked loop (PLL) demodulator. As experimental results, a mass sensitivity of about 190 fg/Hz, and a mass resolution of about 500 fg were obtained in water. The mass sensitivity is 100 times higher than that of a quartz crystal oscillation method. We demonstrated that the sensor can detect the reaction between an antibody of immunoglobulin (IgG) and an antigen of egg albumen (OVA). We confirmed that the binding ratio between the antibody and the antigen was about 1 : 2. The detection method is available for allergy check because the measured reaction ratio occurring on the cantilever concurs with the theoretical method.
NASA Astrophysics Data System (ADS)
Gražulevičiūtė, I.; Garejev, N.; Majus, D.; Jukna, V.; Tamošauskas, G.; Dubietis, A.
2016-02-01
We present a series of measurements, which characterize filamentation dynamics of intense ultrashort laser pulses in the space-time domain, as captured by means of three-dimensional imaging technique in sapphire and fused silica, in the wavelength range of 1.45-2.25 μm, accessing the regimes of weak, moderate and strong anomalous group velocity dispersion (GVD). In the regime of weak anomalous GVD (at 1.45 μm), pulse splitting into two sub-pulses producing a pair of light bullets with spectrally shifted carrier frequencies in both nonlinear media is observed. In contrast, in the regimes of moderate (at 1.8 μm) and strong (at 2.25 μm) anomalous GVD we observe notably different transient dynamics, which however lead to the formation of a single self-compressed quasistationary light bullet with an universal spatiotemporal shape comprised of an extended ring-shaped periphery and a localized intense core that carries the self-compressed pulse.
LD-pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser operating at 1166 and 1176 nm
NASA Astrophysics Data System (ADS)
Sun, Xinzhi; Zhang, Xihe; Li, Shutao; Dong, Yuan
2017-12-01
A laser diode pumped actively Q-switched c-cut Nd:GdVO4 self-Raman laser is experimentally investigated. Simultaneous pulse outputs at 1166 nm and 1176 nm corresponding to the Raman shifts of 807 and 882 cm-1 are acquired. At the pulse repetition frequency (PRF) of 20 kHz, the maximum output power is 103 mW at 1166 nm with the incident pump power of 2.31 W, while 1176 nm output power reaches 530 mW with the incident pump power of 4.11 W. The maximum output power of Raman laser is 570 mW with the incident pump power of 4.11 W and the PRF of 30 kHz. With the incident pump power of 3.67 W and the PRF of 30 kHz, the highest diode-to-Stokes optical conversion efficiency of 14.9% is obtained with the corresponding average output power of 547 mW.
Zhao, Hongyu; Xu, Yan; Wang, Fang; Jiang, Jiang; Zhang, Xiaohui
2015-12-01
Existing studies have found that parent-adolescent conflict frequency and conflict coping tactics influence adolescent family satisfaction and self-satisfaction under the background of Western culture. However, due to differences between Eastern and Western cultures, it is unknown whether previous results of the Western population can be extended to Chinese adolescents. The present study investigated grade differences in parent-adolescent conflict frequency and conflict coping tactics and examined the moderating effects of conflict coping tactics on the relationships between conflict frequency and adolescent family satisfaction and between conflict frequency and adolescent self-satisfaction. Chinese adolescents in Grades 7, 8, 10, and 11 (N = 524) completed measures on conflict frequency, conflict coping tactics, family satisfaction, and self-satisfaction. An analysis of variance (ANOVA) and structural equation model analyses found, first, that conflict frequency decreased with grade level. For coping tactics, conciliation, avoidance, and assertion behaviors increased with grade level. Second, conflict frequency was negatively related to family satisfaction regardless of conciliation and avoidance tactics. By contrast, conflict frequency was negatively related to self-satisfaction when high conciliation and high avoidance behaviors were practiced. In addition, at low conflict frequency conciliation was positively associated with self-satisfaction and was not significant at high conflict frequency.
Coexistence of a self-induced transparency soliton and a Bragg soliton.
Tseng, Hong-Yih; Chi, Sien
2002-11-01
We theoretically show that a self-induced transparency (SIT) soliton and a Bragg soliton can coexist in a nonlinear photonic band gap (PBG) medium doped uniformly with inhomogeneous-broadening two-level atoms. The Maxwell-Bloch equations for the pulse propagating through such a uniformly doped PBG structure are derived first and further reduced to an effective nonlinear Schrödinger equation. This model describes an equivalent physical mechanism for a Bragg-soliton propagation resulting from the effective quadratic dispersion balancing with the effective third-order nonlinearity. Because the resonant atoms are taken into account, the original band gap can be shifted both by the dopants and the instantaneous nonlinearity response originating from an intense optical pulse. As a result, even if a SIT soliton with its central frequency deep inside the original forbidden band, it still can propagate through the resonant PBG medium as long as this SIT soliton satisfies the effective Bragg-soliton propagation. An approximate soliton solution describing such coexistence is found. We also show that the pulse width and group velocity of this soliton solution can be uniquely determined for given material parameters, atomic transition frequency, and input central frequency of the soliton. The numerical examples of the SIT soliton in a one-dimensional As2S3-based PBG structure doped uniformly with Lorentzian line-shape resonant atoms are shown. It is found that a SIT soliton with approximately 100-ps width in such a resonant PBG structure can travel with the velocity being two orders of magnitude slower than the light speed in an unprocessed host medium.
FIBER AND INTEGRATED OPTICS: Radio-frequency electrooptic modulation in optical fibers
NASA Astrophysics Data System (ADS)
Bulyuk, A. N.
1992-10-01
The electrooptic interaction in single-mode optical fibers with both linear and circular birefringe is analyzed. In most cases, a large interaction length imposes a limit on the modulation frequency. A circular birefringence in an optical fiber may lead to an effective coupling of polarization normal modes if a phase-matching condition is satisfied. Through an appropriate choice of polarization states of the light at the entrance and exit of the device, one can achieve a polarization modulation or a frequency shift of the light. There are possible applications in rf polarization modulators, devices for shifting the frequency of light, and detectors of electromagnetic fields.
Method and apparatus for measuring frequency and phase difference
NASA Technical Reports Server (NTRS)
Shores, Paul (Inventor); Lichtenberg, Christopher (Inventor); Kobayashi, Herbert S. (Inventor); Cunningham, Allen R. (Inventor)
1986-01-01
The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.
Optical frequency standards for gravitational wave detection using satellite velocimetry
NASA Astrophysics Data System (ADS)
Vutha, Amar
2015-04-01
Satellite Doppler velocimetry, building on the work of Kaufmann and Estabrook and Wahlquist, is a complementary technique to interferometric methods of gravitational wave detection. This method is based on the fact that the gravitational wave amplitude appears in the apparent Doppler shift of photons propagating from an emitter to a receiver. This apparent Doppler shift can be resolved provided that a frequency standard, capable of quickly averaging down to a high stability, is available. We present a design for a space-capable optical atomic frequency standard, and analyze the sensitivity of satellite Doppler velocimetry for gravitational wave astronomy in the milli-hertz frequency band.
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
Parise, M.
2018-05-18
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parise, M.
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
Prediction of the Lorentz Force Detuning and pressure sensitivity for a Pillbox cavity
NASA Astrophysics Data System (ADS)
Parise, M.
2018-05-01
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effective tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.
Prediction of the Lorentz Force Detuning and Pressure Sensitivity for a Pillbox Cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parise, M.
2018-04-23
The Lorentz Force Detuning (LFD) and the pressure sensitivity are two critical concerns during the design of a Superconducting Radio Frequency (SRF) cavity resonator. The mechanical deformation of the bare Niobium cavity walls, due to the electromagnetic fields and fluctuation of the external pressure in the Helium bath, can dynamically and statically detune the frequency of the cavity and can cause beam phase errors. The frequency shift can be compensated by additional RF power, that is required to maintain the accelerating gradient, or by sophisticated tuning mechanisms and control-compensation algorithms. Passive stiffening is one of the simplest and most effectivemore » tools that can be used during the early design phase, capable of satisfying the Radio Frequency (RF) requisites. This approach requires several multiphysics simulations as well as a deep mechanical and RF knowledge of the phenomena involved. In this paper, is presented a new numerical model for a pillbox cavity that can predict the frequency shifts caused by the LFD and external pressure. This method allows to greatly reduce the computational effort, which is necessary to meet the RF requirements and to keep track of the frequency shifts without using the time consuming multiphysics simulations.« less
NASA Astrophysics Data System (ADS)
Abdulsamad, Feras; Florsch, Nicolas; Schmutz, Myriam; Camerlynck, Christian
2016-12-01
During the last decades, the usage of spectral induced polarization (SIP) measurements in hydrogeology and detecting environmental problems has been extensively increased. However, the physical mechanisms which are responsible for the induced polarization response over the usual frequency range (typically 1 mHz to 10-20 kHz) require better understanding. The phase shift observed at high frequencies is sometimes attributed to the so-called Maxwell-Wagner polarization which takes place when charges cross an interface. However, SIP measurements of tap water show a phase shift at frequencies higher than 1 kHz, where no Maxwell-Wagner polarization may occur. In this paper, we enlighten the possible origin of this phase shift and deduce its likely relationship with the types of the measuring electrodes. SIP Laboratory measurements of tap water using different types of measuring electrodes (polarizable and non-polarizable electrodes) are carried out to detect the origin of the phase shift at high frequencies and the influence of the measuring electrodes types on the observed complex resistivity. Sodium chloride is used to change the conductivity of the medium in order to quantify the solution conductivity role. The results of these measurements are clearly showing the impact of the measuring electrodes type on the measured phase spectrum while the influence on the amplitude spectrum is negligible. The phenomenon appearing on the phase spectrum at high frequency (> 1 kHz) whatever the electrode type is, the phase shows an increase compared to the theoretical response, and the discrepancy (at least in absolute value) increases with frequency, but it is less severe when medium conductivity is larger. Additionally, the frequency corner is shifted upward in frequency. The dependence of this phenomenon on the conductivity and the measuring electrodes type (electrode-electrolyte interface) seems to be due to some dielectric effects (as an electrical double layer of small relaxation time formed at the electrodes interface). Therefore, this dielectric response should be taken into account at high frequency to better analytically separate the medium own response from that linked to the measuring electrodes used. We modeled this effect by adding a capacitance connected in parallel with the traditional equivalent electric circuit used to describe the dielectric response of medium.
Relativistic effects in earth-orbiting Doppler lidar return signals.
Ashby, Neil
2007-11-01
Frequency shifts of side-ranging lidar signals are calculated to high order in the small quantities (v/c), where v is the velocity of a spacecraft carrying a lidar laser or of an aerosol particle that scatters the radiation back into a detector (c is the speed of light). Frequency shift measurements determine horizontal components of ground velocity of the scattering particle, but measured fractional frequency shifts are large because of the large velocities of the spacecraft and of the rotating earth. Subtractions of large terms cause a loss of significant digits and magnify the effect of relativistic corrections in determination of wind velocity. Spacecraft acceleration is also considered. Calculations are performed in an earth-centered inertial frame, and appropriate transformations are applied giving the velocities of scatterers relative to the ground.
Social Work's Response to Poverty: From Benefits Dependence to Economic Self-Sufficiency
ERIC Educational Resources Information Center
Gates, Lauren B.; Koza, Jennifer; Akabas, Sheila H.
2017-01-01
Welfare reform in the 1990s represented a fundamental policy shift in the United States' response to poverty from supporting benefits dependency to promoting economic self-sufficiency. Social work's capacity to integrate this policy shift into practice is central to meeting its mission to alleviate poverty. This study looked at the preparation of…
Shifting Roles, Shifting Contexts, Maintaining Identity
ERIC Educational Resources Information Center
Clift, Renee Tipton
2011-01-01
This self-study describes the ways in which a move to a different state, university, and academic role has shaped my sense of self as a scholar, teacher educator, and college administrator. I draw from role theory and from conceptions of habitus and field to provide a conceptual lens for interpreting the data and my experiences. I then address two…
Connecting Self-Efficacy and Views about the Nature of Science in Undergraduate Research Experiences
ERIC Educational Resources Information Center
Quan, Gina M.; Elby, Andrew
2016-01-01
Undergraduate research can support students' more central participation in physics. We analyze markers of two coupled shifts in participation: changes in students' views about the nature of science coupled to shifts in self-efficacy toward physics research. Students in the study worked with faculty and graduate student mentors on research projects…
Origin of the OH vibrational blue shift in the LiOH crystal.
Hermansson, Kersti; Gajewski, Grzegorz; Mitev, Pavlin D
2008-12-25
The O-H vibrational frequency in crystalline hydroxides is either upshifted or downshifted by its crystalline surroundings. In the LiOH crystal, the experimental gas-to-solid O-H frequency upshift ("blue shift") is approximately +115 cm(-1). Here plane-wave DFT calculations for the isotope-isolated LiOH crystal have been performed and we discuss the origin of the OH frequency upshift, and the nature of the OH group and the interlayer interactions. We find that (1) the vibrational frequency upshift originates from interactions within the LiOH layer; this OH upshift is slightly lessened by the interlayer interactions; (2) the interlayer O-H - - - H-O interaction is largely electrostatic in character (but there is no hydrogen bonding); (3) the gas-to-solid vibrational shift for OH in LiOH(s) and its subsystems qualitatively adheres to a parabola-like "frequency vs electric field strength" correlation curve, which has a maximum for a positive electric field, akin to the correlation curve earlier found in the literature for an isolated OH(-) ion in an electric field.
Microstrip patch antenna for simultaneous strain and temperature sensing
NASA Astrophysics Data System (ADS)
Mbanya Tchafa, F.; Huang, H.
2018-06-01
A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.
Zheng, Hanrong; Fang, Zujie; Wang, Zhaoyong; Lu, Bin; Cao, Yulong; Ye, Qing; Qu, Ronghui; Cai, Haiwen
2018-01-31
It is a basic task in Brillouin distributed fiber sensors to extract the peak frequency of the scattering spectrum, since the peak frequency shift gives information on the fiber temperature and strain changes. Because of high-level noise, quadratic fitting is often used in the data processing. Formulas of the dependence of the minimum detectable Brillouin frequency shift (BFS) on the signal-to-noise ratio (SNR) and frequency step have been presented in publications, but in different expressions. A detailed deduction of new formulas of BFS variance and its average is given in this paper, showing especially their dependences on the data range used in fitting, including its length and its center respective to the real spectral peak. The theoretical analyses are experimentally verified. It is shown that the center of the data range has a direct impact on the accuracy of the extracted BFS. We propose and demonstrate an iterative fitting method to mitigate such effects and improve the accuracy of BFS measurement. The different expressions of BFS variances presented in previous papers are explained and discussed.
Seven, Yasin B.; Mantilla, Carlos B.; Zhan, Wen-Zhi; Sieck, Gary C.
2012-01-01
We hypothesized that diaphragm muscle (DIAm) by a shift in the EMG power spectral density (PSD) to higher frequencies reflects recruitment of more fatigable fast-twitch motor units and motor unit recruitment is reflected by EMG non-stationarity. DIAm EMG was recorded in anesthetized rats during eupnea, hypoxia-hypercapnia (10% O2-5% CO2), airway occlusion, and sneezing (maximal DIAm force). Although power in all frequency bands increased progressively across motor behaviors, PSD centroid frequency increased only during sneezing (p<0.05). The non-stationary period at the onset of EMG activity ranged from ~70 ms during airway occlusion to ~150 ms during eupnea. Within the initial non-stationary period of EMG activity 80–95% of motor units were recruited during different motor behaviors. Motor units augmented their discharge frequencies progressively beyond the non-stationary period; yet, EMG signal became stationary. In conclusion, non-stationarity of DIAm EMG reflects the period of motor unit recruitment, while a shift in the PSD towards higher frequencies reflects recruitment of more fatigable fast-twitch motor units. PMID:22986086
Applications of Space-Time Duality
NASA Astrophysics Data System (ADS)
Plansinis, Brent W.
The concept of space-time duality is based on a mathematical analogy between paraxial diffraction and narrowband dispersion, and has led to the development of temporal imaging systems. The first part of this thesis focuses on the development of a temporal imaging system for the Laboratory for Laser Energetics. Using an electro-optic phase modulator as a time lens, a time-to-frequency converter is constructed capable of imaging pulses between 3 and 12 ps. Numerical simulations show how this system can be improved to image the 1-30 ps range used in OMEGA-EP. By adjusting the timing between the pulse and the sinusoidal clock of the phase modulator, the pulse spectrum can be selectively narrowed, broadened, or shifted. An experimental demonstration of this effect achieved spectral narrowing and broadening by a factor of 2. Numerical simulations show narrowing by a factor of 8 is possible with modern phase modulators. The second part of this thesis explores the space-time analog of reflection and refraction from a moving refractive index boundary. From a physics perspective, a temporal boundary breaks translational symmetry in time, requiring the momentum of the photon to remain unchanged while its energy may change. This leads to a shifting and splitting of the pulse spectrum as the boundary is crossed. Equations for the reflected and transmitted frequencies and a condition for total internal reflection are found. Two of these boundaries form a temporal waveguide, which confines the pulse to a narrow temporal window. These waveguides have a finite number of modes, which do not change during propagation. A single-mode waveguide can be created, allowing only a single pulse shape to form within the waveguide. Temporal reflection and refraction produce a frequency dependent phase shift on the incident pulse, leading to interference fringes between the incident light and the reflected light. In a waveguide, this leads to self-imaging, where the pulse shape reforms periodically at finite propagation lengths. Numerical simulations are performed for the specific case where the moving boundary is produced through cross-phase modulation. In this case, the Kerr nonlinearity causes the boundary to change during propagation, leading to unique temporal and spectral behavior.
Cai, Guangyu; Sun, Jianfeng; Li, Guangyuan; Zhang, Guo; Xu, Mengmeng; Zhang, Bo; Yue, Chaolei; Liu, Liren
2016-06-10
A self-homodyne laser communication system based on orthogonally polarized binary phase shift keying is demonstrated. The working principles of this method and the structure of a transceiver are described using theoretical calculations. Moreover, the signal-to-noise ratio, sensitivity, and bit error rate are analyzed for the amplifier-noise-limited case. The reported experiment validates the feasibility of the proposed method and demonstrates its advantageous sensitivity as a self-homodyne communication system.
Discrimination of rippled-spectrum patterns in noise: A manifestation of compressive nonlinearity
Milekhina, Olga N.; Nechaev, Dmitry I.; Klishin, Vladimir O.
2017-01-01
In normal-hearing listeners, rippled-spectrum discrimination was psychophysically investigated in both silence and with a simultaneous masker background using the following two paradigms: measuring the ripple density resolution with the phase-reversal test and measuring the ripple-shift threshold with the ripple-shift test. The 0.5-oct wide signal was centered on 2 kHz, the signal levels were 50 and 80 dB SPL, and the masker levels varied from 30 to 100 dB SPL. The baseline ripple density resolutions were 8.7 oct-1 and 8.6 oct-1 for the 50-dB and 80-dB signals, respectively. The baseline ripple shift thresholds were 0.015 oct and 0.018 oct for the 50-dB and 80-dB signals, respectively. The maskers were 0.5-oct noises centered on 2 kHz (on-frequency) or 0.75 to 1.25 oct below the signal (off-frequency maskers). The effects of the maskers were as follows: (i) both on- and low-frequency maskers reduced the ripple density resolution and increased the ripple shift thresholds, (ii) the masker levels at threshold (the ripple density resolution decrease down to 3 oct–1 or ripple shift threshold increased up to 0.1 oct) increased with increasing frequency spacing between the signal and masker, (iii) the masker levels at threshold were higher for the 80-dB signal than for the 50-dB signal, and (iv) the difference between the masker levels at threshold for the 50-dB and 80-dB signals decreased with increasing frequency spacing between the masker and signal. Within the 30-dB (from 50 to 80 dB SPL) signal level, the growth of the masker level at threshold was 27.8 dB for the on-frequency masker and 9 dB for the low-frequency masker. It is assumed that the difference between the on- and low-frequency masking of the rippled-spectrum discrimination reflects the cochlear compressive non-linearity. With this assumption, the compression was 0.3 dB/dB. PMID:28346538
The time course of spoken word learning and recognition: studies with artificial lexicons.
Magnuson, James S; Tanenhaus, Michael K; Aslin, Richard N; Dahan, Delphine
2003-06-01
The time course of spoken word recognition depends largely on the frequencies of a word and its competitors, or neighbors (similar-sounding words). However, variability in natural lexicons makes systematic analysis of frequency and neighbor similarity difficult. Artificial lexicons were used to achieve precise control over word frequency and phonological similarity. Eye tracking provided time course measures of lexical activation and competition (during spoken instructions to perform visually guided tasks) both during and after word learning, as a function of word frequency, neighbor type, and neighbor frequency. Apparent shifts from holistic to incremental competitor effects were observed in adults and neural network simulations, suggesting such shifts reflect general properties of learning rather than changes in the nature of lexical representations.
Konorov, S O; Akimov, D A; Zheltikov, A M; Ivanov, A A; Alfimov, M V; Scalora, M
2005-06-15
Femtosecond pulses of fundamental Cr:forsterite laser radiation are used as a pump field to tune the frequency of copropagating second-harmonic pulses of the same laser through cross-phase modulation in a photonic crystal fiber. Sub-100-kW femtosecond pump pulses coupled into a photonic crystal fiber with an appropriate dispersion profile can shift the central frequency of the probe field by more than 100 nm, suggesting a convenient way to control propagation and spectral transformations of ultrashort laser pulses.
New ion trap for atomic frequency standard applications
NASA Technical Reports Server (NTRS)
Prestage, J. D.; Dick, G. J.; Maleki, L.
1989-01-01
A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.
Time Shifted PN Codes for CW Lidar, Radar, and Sonar
NASA Technical Reports Server (NTRS)
Campbell, Joel F. (Inventor); Prasad, Narasimha S. (Inventor); Harrison, Fenton W. (Inventor); Flood, Michael A. (Inventor)
2013-01-01
A continuous wave Light Detection and Ranging (CW LiDAR) system utilizes two or more laser frequencies and time or range shifted pseudorandom noise (PN) codes to discriminate between the laser frequencies. The performance of these codes can be improved by subtracting out the bias before processing. The CW LiDAR system may be mounted to an artificial satellite orbiting the earth, and the relative strength of the return signal for each frequency can be utilized to determine the concentration of selected gases or other substances in the atmosphere.
Electro-optic-waveguide frequency translator in LiNbO(3) fabricated by proton exchange.
Wong, K K; De La Rue, R M; Wright, S
1982-11-01
An optical waveguide phase modulator has been fabricated on X-cut LiNbO(3) by using proton exchange in benzoic acid. The phase modulator was operated as a serrodyne optical-frequency translator with shifted-signal to imagesignal discrimination of 52 dB for a 4-MHz frequency shift. The amplitude of the sawtooth driving signal was 10 V peak to peak. Application of a de bias voltage of either polarity was found to cause a substantial reduction in transmitted-light intensity.
Gómez-García, Teresa; Ruzafa-Martínez, María; Fuentelsaz-Gallego, Carmen; Madrid, Juan Antonio; Rol, Maria Angeles; Martínez-Madrid, María José; Moreno-Casbas, Teresa
2016-01-01
Objective The main objective of this study was to determine the relationship between the characteristics of nurses' work environments in hospitals in the Spanish National Health System (SNHS) with nurse reported quality of care, and how care was provided by using different shifts schemes. The study also examined the relationship between job satisfaction, burnout, sleep quality and daytime drowsiness of nurses and shift work. Methods This was a multicentre, observational, descriptive, cross-sectional study, centred on a self-administered questionnaire. The study was conducted in seven SNHS hospitals of different sizes. We recruited 635 registered nurses who worked on day, night and rotational shifts on surgical, medical and critical care units. Their average age was 41.1 years, their average work experience was 16.4 years and 90% worked full time. A descriptive and bivariate analysis was carried out to study the relationship between work environment, quality and safety care, and sleep quality of nurses working different shift patterns. Results 65.4% (410) of nurses worked on a rotating shift. The Practice Environment Scale of the Nursing Work Index classification ranked 20% (95) as favourable, showing differences in nurse manager ability, leadership and support between shifts (p=0.003). 46.6% (286) were sure that patients could manage their self-care after discharge, but there were differences between shifts (p=0.035). 33.1% (201) agreed with information being lost in the shift change, showing differences between shifts (p=0.002). The Pittsburgh Sleep Quality Index reflected an average of 6.8 (SD 3.39), with differences between shifts (p=0.017). Conclusions Nursing requires shift work, and the results showed that the rotating shift was the most common. Rotating shift nurses reported worse perception in organisational and work environmental factors. Rotating and night shift nurses were less confident about patients' competence of self-care after discharge. The most common nursing care omissions reported were related to nursing care plans. For the Global Sleep Quality score, difference were found between day and night shift workers. PMID:27496241
Jüschke, M; Koch, C; Dreyer, T
2014-09-01
The efficiency of ultrasonic cleaning vessels cannot be measured directly in an easy way. In the presented work, a sensor is developed which quantitatively measures the ablation of a test layer. The sensor element is a quartz crystal which is coated with a sacrificial layer. Small changes in mass of this layer can be measured by a frequency shift of the crystal oscillation. For measurements, a 10 MHz AT-cut quartz crystal was used in a cleaning vessel working at 44.9 kHz. To determine the frequency shift by the ablation of the test layer, the quartz crystal was driven by a frequency generator sweeping the frequency in the range of the resonance frequency and a characteristic frequency was determined. The test layer which was applied to the quartz crystal consisted of silica microparticles suspended in varnish. In a preliminary experiment using a commercial cleaner it could be shown that significant changes in resonance frequency by cavitation effect could be detected. The initial frequency shift of the sacrificial layer is reproducible within 10%. The test layer can be adapted to the conditions of the cleaning vessel. By changing the electrical input power of the vessel, a threshold in the cavitation erosion was found. Copyright © 2014 Elsevier B.V. All rights reserved.
Frequency Invariability of (Pb,La)(Zr,Ti)O₃ Antiferroelectric Thick-Film Micro-Cantilevers.
An, Kun; Jin, Xuechen; Meng, Jiang; Li, Xiao; Ren, Yifeng
2018-05-13
Micro-electromechanical systems comprising antiferroelectric layers can offer both actuation and transduction to integrated technologies. Micro-cantilevers based on the (Pb 0.97 La 0.02 )(Zr 0.95 Ti 0.05 )O₃ (PLZT) antiferroelectric thick film are fabricated by the micro-nano manufacturing process, to utilize the effect of phase transition induced strain and sharp phase switch of antiferroelectric materials. When micro-cantilevers made of antiferroelectric thick films were driven by sweep voltages, there were two resonant peaks corresponding to the natural frequency shift from 27.8 to 27.0 kHz, before and after phase transition. This is the compensation principle for the PLZT micro-cantilever to tune the natural frequency by the amplitude modulation of driving voltage, rather than of frequency modulation. Considering the natural frequency shift about 0.8 kHz and the frequency tuning ability about 156 Hz/V before the phase transition, this can compensate the frequency shift caused by increasing temperature by tuning only the amplitude of driving voltage, when the ultrasonic micro-transducer made of antiferroelectric thick films works for such a long period. Therefore, antiferroelectric thick films with hetero-structures incorporated into PLZT micro-cantilevers not only require a lower driving voltage (no more than 40 V) than rival bulk piezoelectric ceramics, but also exhibit better performance of frequency invariability, based on the amplitude modulation.
Raanan, Dekel; Ren, Liqing; Oron, Dan; Silberberg, Yaron
2018-02-01
Stimulated Raman scattering (SRS) has recently become useful for chemically selective bioimaging. It is usually measured via modulation transfer from the pump beam to the Stokes beam. Impulsive stimulated Raman spectroscopy, on the other hand, relies on the spectral shift of ultrashort pulses as they propagate in a Raman active sample. This method was considered impractical with low energy pulses since the observed shifts are very small compared to the excitation pulse bandwidth, spanning many terahertz. Here we present a new apparatus, using tools borrowed from the field of precision measurement, for the detection of low-frequency Raman lines via stimulated-Raman-scattering-induced spectral shifts. This method does not require any spectral filtration and is therefore an excellent candidate to resolve low-lying Raman lines (<200 cm -1 ), which are commonly masked by the strong Rayleigh scattering peak. Having the advantage of the high repetition rate of the ultrafast oscillator, we reduce the noise level by implementing a lock-in detection scheme with a wavelength shift sensitivity well below 100 fm. This is demonstrated by the measurement of low-frequency Raman lines of various liquid samples.
Perceptual adaptation of voice gender discrimination with spectrally shifted vowels.
Li, Tianhao; Fu, Qian-Jie
2011-08-01
To determine whether perceptual adaptation improves voice gender discrimination of spectrally shifted vowels and, if so, which acoustic cues contribute to the improvement. Voice gender discrimination was measured for 10 normal-hearing subjects, during 5 days of adaptation to spectrally shifted vowels, produced by processing the speech of 5 male and 5 female talkers with 16-channel sine-wave vocoders. The subjects were randomly divided into 2 groups; one subjected to 50-Hz, and the other to 200-Hz, temporal envelope cutoff frequencies. No preview or feedback was provided. There was significant adaptation in voice gender discrimination with the 200-Hz cutoff frequency, but significant improvement was observed only for 3 female talkers with F(0) > 180 Hz and 3 male talkers with F(0) < 170 Hz. There was no significant adaptation with the 50-Hz cutoff frequency. Temporal envelope cues are important for voice gender discrimination under spectral shift conditions with perceptual adaptation, but spectral shift may limit the exclusive use of spectral information and/or the use of formant structure on voice gender discrimination. The results have implications for cochlear implant users and for understanding voice gender discrimination.
Perceptual Adaptation of Voice Gender Discrimination with Spectrally Shifted Vowels
Li, Tianhao; Fu, Qian-Jie
2013-01-01
Purpose To determine whether perceptual adaptation improves voice gender discrimination of spectrally shifted vowels and, if so, which acoustic cues contribute to the improvement. Method Voice gender discrimination was measured for 10 normal-hearing subjects, during 5 days of adaptation to spectrally shifted vowels, produced by processing the speech of 5 male and 5 female talkers with 16-channel sine-wave vocoders. The subjects were randomly divided into 2 groups; one subjected to 50-Hz, and the other to 200-Hz, temporal envelope cutoff frequencies. No preview or feedback was provided. Results: There was significant adaptation in voice gender discrimination with the 200-Hz cutoff frequency, but significant improvement was observed only for 3 female talkers with F0 > 180 Hz and 3 male talkers with F0 < 170 Hz. There was no significant adaptation with the 50-Hz cutoff frequency. Conclusions Temporal envelope cues are important for voice gender discrimination under spectral shift conditions with perceptual adaptation, but spectral shift may limit the exclusive use of spectral information and/or the use of formant structure on voice gender discrimination. The results have implications for cochlear implant users and for understanding voice gender discrimination. PMID:21173392
Stimulated concentration (diffusion) light scattering on nanoparticles in a liquid suspension
NASA Astrophysics Data System (ADS)
Burkhanov, I. S.; Krivokhizha, S. V.; Chaikov, L. L.
2016-06-01
A nonlinear growth of the light scattering intensity has been observed and the frequency shift of the spectral line of scattered light has been measured in light backscattered in suspensions of diamond and latex nanoparticles in water. The shift corresponds to the HWHM of the line of spontaneous scattering on particles. We may conclude that there exists stimulated concentration (diffusion) light scattering on variations of the particle concentration, which is also called the stimulated Mie scattering. In a fibre probe scheme, the growth of the shift of the scattered spectral line is observed with an increase in the exciting beam power. The variation of the frequency shift with an increase in the exciting power is explained by convection in liquid.
Broadband one-dimensional photonic crystal wave plate containing single-negative materials.
Chen, Yihang
2010-09-13
The properties of the phase shift of wave reflected from one-dimensional photonic crystals consisting of periodic layers of single-negative (permittivity- or permeability-negative) materials are demonstrated. As the incident angle increases, the reflection phase shift of TE wave decreases, while that of TM wave increases. The phase shifts of both polarized waves vary smoothly as the frequency changes across the photonic crystal stop band. Consequently, the difference between the phase shift of TE and that of TM wave could remain constant in a rather wide frequency range inside the stop band. These properties are useful to design wave plate or retarder which can be used in wide spectral band. In addition, a broadband photonic crystal quarter-wave plate is proposed.
Tiriveedhi, V; Angaswamy, N; Brand, D; Weber, J; Gelman, A G; Hachem, R; Trulock, E P; Meyers, B; Patterson, G; Mohanakumar, T
2012-01-01
Immune responses to human leucocyte antigen (HLA) and self-antigen collagen V (Col-V) have been proposed in the pathogenesis of chronic rejection (bronchiolitis obliterans syndrome, BOS) following human lung transplantation (LTx). In this study, we defined the role for the shift in immunodominant epitopes of Col-V in inducing T helper phenotype switch leading to immunity to Col-V and BOS. Sera and lavage from BOS(+) LTx recipients with antibodies to Col-V were analysed. Two years prior to BOS, patients developed antibodies to both Col-V,α1(V) and α2(V) chains. However, at clinical diagnosis of BOS, antibodies became restricted to α1(V). Further, lung biopsy from BOS(+) patients bound to antibodies to α1(V), indicating that these epitopes are exposed. Fourteen Col-V peptides [pep1-14, pep1-4 specific to α1(V), pep5-8 to α1,2(V) and pep9-14 to α2(V)] which bind to HLA-DR4 and -DR7, demonstrated that prior to BOS, pep 6, 7, 9, 11 and 14 were immunodominant and induced interleukin (IL)-10. However, at BOS, the response switched to pep1, 4 and 5 and induced interferon (IFN)-γ and IL-17 responses, but not IL-10. The T helper (Th) phenotype switch is accompanied by decreased frequency of regulatory T cells (T(regs) ) in the lavage. LTx recipients with antibodies to α1(V) also demonstrated increased matrix metalloproteinase (MMP) activation with decreased MMP inhibitor, tissue inhibitor of metalloproteinase (TIMP), suggesting that MMP activation may play a role in the exposure of new Col-V antigenic epitopes. We conclude that a shift in immunodominance of self-antigenic determinants of Col-V results in induction of IFN-γ and IL-17 with loss of tolerance leading to autoimmunity to Col-V, which leads to chronic lung allograft rejection. © 2011 The Authors. Clinical and Experimental Immunology © 2011 British Society for Immunology.
NASA Astrophysics Data System (ADS)
Yuya, Philip A.; Wen, Yongkui; Turner, Joseph A.; Dzenis, Yuris A.; Li, Zheng
2007-03-01
The authors report a technique for measuring Young's modulus of a single electrospun nanofiber using the vibrations of two microcantilevers coupled with the nanofiber. The modulus is calculated from the resonant frequency shift resulting from the nanofiber. Polyacrylonitrile nanofibers (200nm diameter) were collected during electrospinning and wrapped on two similar microcantilevers causing a shift in first resonance from 10.0to19.4kHz. Finite element analysis was used to analyze the frequency shift using images from a scanning electron microscope giving a modulus of the as-spun polyacrylonitrile nanofiber of 26.8GPa.
NASA Astrophysics Data System (ADS)
Ibrahim, Dahi Ghareab Abdelsalam; Yasui, Takeshi
2018-04-01
Two-wavelength phase-shift interferometry guided by optical frequency combs is presented. We demonstrate the operation of the setup with a large step sample simultaneously with a resolution test target with a negative pattern. The technique can investigate multi-objects simultaneously with high precision. Using this technique, several important applications in metrology that require high speed and precision are demonstrated.
Performance on a strategy set shifting task in rats following adult or adolescent cocaine exposure
Kantak, Kathleen M.; Barlow, Nicole; Tassin, David H.; Brisotti, Madeline F.; Jordan, Chloe J
2014-01-01
Rationale Neuropsychological testing is widespread in adult cocaine abusers, but lacking in teens. Animal models may provide insight into age-related neuropsychological consequences of cocaine exposure. Objectives Determine whether developmental plasticity protects or hinders behavioral flexibility after cocaine exposure in adolescent vs. adult rats. Methods Using a yoked-triad design, one rat controlled cocaine delivery and the other two passively received cocaine or saline. Rats controlling cocaine delivery (1.0 mg/kg) self-administered for 18 sessions (starting P37 or P77), followed by 18 drug-free days. Rats next were tested in a strategy set shifting task, lasting 11–13 sessions. Results Cocaine self-administration did not differ between age groups. During initial set formation, adolescent-onset groups required more trials to reach criterion and made more errors than adult-onset groups. During the set shift phase, rats with adult-onset cocaine self-administration experience had higher proportions of correct trials and fewer perseverative + regressive errors than age-matched yoked-controls or rats with adolescent-onset cocaine self-administration experience. During reversal learning, rats with adult-onset cocaine experience (self-administered or passive) required fewer trials to reach criterion and the self-administering rats made fewer perseverative + regressive errors than yoked-saline rats. Rats receiving adolescent-onset yoked-cocaine had more trial omissions and longer lever press reaction times than age-matched rats self-administering cocaine or receiving yoked-saline. Conclusions Prior cocaine self-administration may impair memory to reduce proactive interference during set shifting and reversal learning in adult-onset but not adolescent-onset rats (developmental plasticity protective). Passive cocaine may disrupt aspects of executive function in adolescent-onset but not adult-onset rats (developmental plasticity hinders). PMID:24800898
Self-Broadening and Self-Shift Coefficients in the Fundamental Band of 12C 16O
NASA Technical Reports Server (NTRS)
Devi, Malathy V.; Benner, D. Chris; Smith, Mary Ann H.; Rinsland, Curtis P.
1998-01-01
High quality and precise measurements of self-broadened and self-shift coefficients in the fundamental band of C-12O-16 were made using spectra recorded at room temperature with the high-resolution (0.0027 cm(exp -1)) McMath-Pierce Fourier transform spectrometer located at the National Solar Observatory on Kitt Peak, Arizona. The spectral region under investigation (2008-2247 cm(exp -1)) contains the P(31) to R(31) transitions. The data were obtained using a high-purity natural isotopic sample ofcarbon monoxide and two absorption cells with pathlengths of 4.08 and 9.98 cm, respectively. Various pressures of CO were used, ranging between 0.25 and 201.2 Torr. The results were obtained by analyzing five spectra simultaneously, using a multispectrum nonlinear least-squares fitting technique. The self-broadened coefficients ranged from 0.0426(2) cm(exp -1) atm(exp -1) at 296 K to 0.0924(2) cm(exp -1) atm(exp -1) at 296 K, while the pressure-induced shift coefficients varied between -0.0042(3) cm(exp -1) atm(exp -1) at 296 K and +0.0005(l) cm(exp -1) atm(exp -1) at 296 K. The value in parentheses is the estimated uncertainty in units of the last digit. The self-broadened coefficients of lines with same values of m in the P and R branches agree close to within experimental uncertainties while the self-shift coefficients showed considerable variation within and between the two branches. The mean value of the ratios of P branch to R branch self-broadened coefficients was found to be 1.01 with a standard deviation of + or - 0.01. Comparisons of the results with other published data were made.
Young, Laura K; Smithson, Hannah E
2014-01-01
There is evidence that letter identification is mediated by only a narrow band of spatial frequencies and that the center frequency of the neural channel thought to underlie this selectivity is related to the size of the letters. When letters are spatially filtered (at a fixed size) the channel tuning characteristics change according to the properties of the spatial filter (Majaj et al., 2002). Optical aberrations in the eye act to spatially filter the image formed on the retina-their effect is generally to attenuate high frequencies more than low frequencies but often in a non-monotonic way. We might expect the change in the spatial frequency spectrum caused by the aberration to predict the shift in channel tuning observed for aberrated letters. We show that this is not the case. We used critical-band masking to estimate channel-tuning in the presence of three types of aberration-defocus, coma and secondary astigmatism. We found that the maximum masking was shifted to lower frequencies in the presence of an aberration and that this result was not simply predicted by the spatial-frequency-dependent degradation in image quality, assessed via metrics that have previously been shown to correlate well with performance loss in the presence of an aberration. We show that if image quality effects are taken into account (using visual Strehl metrics), the neural channel required to model the data is shifted to lower frequencies compared to the control (no-aberration) condition. Additionally, we show that when spurious resolution (caused by π phase shifts in the optical transfer function) in the image is masked, the channel tuning properties for aberrated letters are affected, suggesting that there may be interference between visual channels. Even in the presence of simulated aberrations, whose properties change from trial-to-trial, observers exhibit flexibility in selecting the spatial frequencies that support letter identification.
Applying time-frequency analysis to assess cerebral autoregulation during hypercapnia.
Placek, Michał M; Wachel, Paweł; Iskander, D Robert; Smielewski, Peter; Uryga, Agnieszka; Mielczarek, Arkadiusz; Szczepański, Tomasz A; Kasprowicz, Magdalena
2017-01-01
Classic methods for assessing cerebral autoregulation involve a transfer function analysis performed using the Fourier transform to quantify relationship between fluctuations in arterial blood pressure (ABP) and cerebral blood flow velocity (CBFV). This approach usually assumes the signals and the system to be stationary. Such an presumption is restrictive and may lead to unreliable results. The aim of this study is to present an alternative method that accounts for intrinsic non-stationarity of cerebral autoregulation and the signals used for its assessment. Continuous recording of CBFV, ABP, ECG, and end-tidal CO2 were performed in 50 young volunteers during normocapnia and hypercapnia. Hypercapnia served as a surrogate of the cerebral autoregulation impairment. Fluctuations in ABP, CBFV, and phase shift between them were tested for stationarity using sphericity based test. The Zhao-Atlas-Marks distribution was utilized to estimate the time-frequency coherence (TFCoh) and phase shift (TFPS) between ABP and CBFV in three frequency ranges: 0.02-0.07 Hz (VLF), 0.07-0.20 Hz (LF), and 0.20-0.35 Hz (HF). TFPS was estimated in regions locally validated by statistically justified value of TFCoh. The comparison of TFPS with spectral phase shift determined using transfer function approach was performed. The hypothesis of stationarity for ABP and CBFV fluctuations and the phase shift was rejected. Reduced TFPS was associated with hypercapnia in the VLF and the LF but not in the HF. Spectral phase shift was also decreased during hypercapnia in the VLF and the LF but increased in the HF. Time-frequency method led to lower dispersion of phase estimates than the spectral method, mainly during normocapnia in the VLF and the LF. The time-frequency method performed no worse than the classic one and yet may offer benefits from lower dispersion of phase shift as well as a more in-depth insight into the dynamic nature of cerebral autoregulation.
An inductor-based converter with EMI reduction for low-voltage thermoelectric energy harvesting
NASA Astrophysics Data System (ADS)
Wang, Chuang; Zhao, Kai; Li, Zunchao
2017-07-01
This paper presents a self-powered inductor-based converter which harvests thermoelectric energy and boosts extremely low voltage to a typical voltage level for supplying body sensor nodes. Electromagnetic interference (EMI) of the converter is reduced by spreading spectrum of fundamental frequency and harmonics via pseudo-random modulation, which is obtained via combining the linear feedback shift register and digitally controlled oscillator. Besides, the methods, namely extracting energy near MPP and reducing the power dissipation, are employed to improve the power efficiency. The presented inductor-based converter is designed and verified in CSMC CMOS 0.18-µm 1P6M process. The results reveal that it achieves the high efficiency and EMI reduction at the same time.
On the physical origin of blue-shifted hydrogen bonds.
Li, Xiaosong; Liu, Lei; Schlegel, H Bernhard
2002-08-14
For blue-shifted hydrogen-bonded systems, the hydrogen stretching frequency increases rather than decreases on complexation. In computations at various levels of theory, the blue-shift in the archetypical system, F(3)C-H.FH, is reproduced at the Hartree-Fock level, indicating that electron correlation is not the primary cause. Calculations also demonstrate that a blue-shift does not require either a carbon center or the absence of a lone pair on the proton donor, because F(3)Si-H.OH(2), F(2)NH.FH, F(2)PH.NH(3), and F(2)PH.OH(2) have substantial blue-shifts. Orbital interactions are shown to lengthen the X-H bond and lower its vibrational frequency, and thus cannot be the source of the blue-shift. In the F(3)CH.FH system, the charge redistribution in F(3)CH can be reproduced very well by replacing the FH with a simple dipole, which suggests that the interactions are predominantly electrostatic. When modeled with a point charge for the proton acceptor, attractive electrostatic interactions elongate the F(3)C-H, while repulsive interactions shorten it. At the equilibrium geometry of a hydrogen-bonded complex, the electrostatic attraction between the dipole moments of the proton donor and proton acceptor must be balanced by the Pauli repulsion between the two fragments. In the absence of orbital interactions that cause bond elongation, this repulsive interaction leads to compression of the X-H bond and a blue-shift in its vibrational frequency.
Efficient detection of a CW signal with a linear frequency drift
NASA Technical Reports Server (NTRS)
Swarztrauber, Paul N.; Bailey, David H.
1989-01-01
An efficient method is presented for the detection of a continuous wave (CW) signal with a frequency drift that is linear in time. Signals of this type occur in transmissions between any two locations that are accelerating relative to one another, e.g., transmissions from the Voyager spacecraft. We assume that both the frequency and the drift are unknown. We also assume that the signal is weak compared to the Gaussian noise. The signal is partitioned into subsequences whose discrete Fourier transforms provide a sequence of instantaneous spectra at equal time intervals. These spectra are then accumulated with a shift that is proportional to time. When the shift is equal to the frequency drift, the signal to noise ratio increases and detection occurs. Here, we show how to compute these accumulations for many shifts in an efficient manner using a variety of Fast Fourier Transformations (FFT). Computing time is proportional to L log L where L is the length of the time series.
I feel good! Gender differences and reporting heterogeneity in self-assessed health.
Schneider, Udo; Pfarr, Christian; Schneider, Brit S; Ulrich, Volker
2012-06-01
For empirical analysis and policy-oriented recommendations, the precise measurement of individual health or well-being is essential. The difficulty is that the answer may depend on individual reporting behaviour. Moreover, if an individual's health perception varies with certain attitudes of the respondent, reporting heterogeneity may lead to index or cut-point shifts of the health distribution, causing estimation problems. An index shift is a parallel shift in the thresholds of the underlying distribution of health categories. In contrast, a cut-point shift means that the relative position of the thresholds changes, implying different response behaviour. Our paper aims to detect how socioeconomic determinants and health experiences influence the individual valuation of health. We analyse the reporting behaviour of individuals on their self-assessed health status, a five-point categorical variable. Using German panel data, we control for observed heterogeneity in the categorical health variable as well as unobserved individual heterogeneity in the panel estimation. In the empirical analysis, we find strong evidence for cut-point shifts. Our estimation results show different impacts of socioeconomic and health-related variables on the five categories of self-assessed health. Moreover, the answering behaviour varies between female and male respondents, pointing to gender-specific perception and assessment of health. Hence, in case of reporting heterogeneity, using self-assessed measures in empirical studies may be misleading and the information needs to be handled with care.
NASA Astrophysics Data System (ADS)
Lee, Seung Seok; Kim, Ju Ha; Choi, Eun Seo
2017-04-01
We proposed novel phase-shifting interferometry using a fiber-optic vibration sensor. The Doppler shift in the coiled fiber caused by vibrations can be used to detect the vibrations by using a fiber-optic interferometer. The principle can be applied to induce phase shifts. While applying vibrations to the coiled fiber at various vibration frequencies, we recorded the variations in the interference fringes. The interference fringe moved to longer wavelengths when a vibration frequency was increased from 38.00 to 38.40 kHz. Phase variations of 3.59 rad/kHz were obtained. The ability to accurately control the phase by using the vibrations in the coiled fiber was demonstrated by the elimination of the depth degeneracy using the complex signal generated by the phase-shifted interference fringes. Using vibrations to control phase shifting can be an acceptable alternative to conventional methods and can be applied to resolve the depth ambiguity in Fourier domain optical coherence tomography.
Uniaxial stress induced symmetry breaking for muon sites in Fe
NASA Technical Reports Server (NTRS)
Kossler, W. J.; Namkung, M.; Hitti, B.; Li, Y.; Kempton, J.; Stronach, C. E.; Goode, L. R., Jr.; Lankford, W. F.; Patterson, B. D.; Kuendig, W.
1984-01-01
Uniaxial stress was used on Fe single crystals to induce muon precession frequency shifts. The frequency shift for a nominally pure Fe sample at 302K was -0.34 + or - .023 MHz per 100 microstrain along the 100 magnetization axis. This corresponds to a change of magnetic field at the muon of 25.1 + to 1.6G/100 magnetic moment. For an Fe (3wt%Si) single crystal the shifts were -0.348 + or - .008 MHz/100 magnetic moment. The agreement between the shifts for Fe and Fe(3wt%Si) shows the effect to be intrinsic to iron and not strongly impurity sensitive. These shifts and their temperature dependence (1/T) are dominated by the effect of strain inducted population shifts between crystallographically equivalent, but mgnetically inequivalent sites. Their magnitudes are in good agreement ith previous theoretical predictions and by previous extrapolation from calculations on Nb and V especially if both 4T(0) and 1T sites contribute comparably.
Investigating lipids as a source of chemical exchange-induced MRI frequency shifts.
Shmueli, K; Dodd, S J; van Gelderen, P; Duyn, J H
2017-04-01
While magnetic susceptibility is a major contributor to NMR resonance frequency variations in the human brain, a substantial contribution may come from the chemical exchange of protons between water and other molecules. Exchange-induced frequency shifts f e have been measured in tissue and protein solutions, but relatively lipid-rich white matter (WM) has a larger f e than gray matter, suggesting that lipids could contribute. Galactocerebrosides (GC) are a prime candidate as they are abundant in WM and susceptible to exchange. To investigate this, f e was measured in a model of WM lipid membranes in the form of multilamellar vesicles (MLVs), consisting of a 1:2 molar ratio of GC and phospholipids (POPC), and in MLVs with POPC only. Chemical shift imaging with 15% volume fraction of dioxane, an internal reference whose protons are assumed not to undergo chemical exchange, was used to remove susceptibility-induced frequency shifts in an attempt to measure f e in MLVs at several lipid concentrations. Initial analysis of these measurements indicated a necessity to correct for small unexpected variations in dioxane concentration due to its effect on the water frequency shift. To achieve this, the actual dioxane concentration was inferred from spectral analysis and its additional contribution to f e was removed through separate experiments which showed that the water-dioxane frequency shift depended linearly on the dioxane concentration at low concentrations with a proportionality constant of -0.021 ± 0.002 ppb/mM in agreement with published experiments. Contrary to expectations and uncorrected results, for GC + POPC vesicles, the dependence of the corrected f e on GC concentration was insignificant (0.023 ± 0.037 ppb/mM; r 2 = 0.085, p > 0.57), whereas for the POPC-only vesicles a small but significant linear increase with POPC concentration was found: 0.044 ± 0.008 ppb/mM (r 2 = 0.877, p < 0.01). These findings suggest that the exchange-induced contribution of lipids to frequency contrast in WM may be small. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Light shift measurements in a Cesium Fountain without the use of mechanical shutters
NASA Technical Reports Server (NTRS)
Tjoelker, Robert L.; Enzer, D. G.; Klipstein, W. M.
2005-01-01
We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.
RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.
Melik, Rohat; Unal, Emre; Perkgoz, Nihan Kosku; Puttlitz, Christian; Demir, Hilmi Volkan
2011-03-01
In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.
Treesuwan, Witcha; Hirao, Hajime; Morokuma, Keiji; Hannongbua, Supa
2012-05-01
As the mechanism underlying the sense of smell is unclear, different models have been used to rationalize structure-odor relationships. To gain insight into odorant molecules from bread baking, binding energies and vibration spectra in the gas phase and in the protein environment [7-transmembrane helices (7TMHs) of rhodopsin] were calculated using density functional theory [B3LYP/6-311++G(d,p)] and ONIOM [B3LYP/6-311++G(d,p):PM3] methods. It was found that acetaldehyde ("acid" category) binds strongly in the large cavity inside the receptor, whereas 2-ethyl-3-methylpyrazine ("roasted") binds weakly. Lys296, Tyr268, Thr118 and Ala117 were identified as key residues in the binding site. More emphasis was placed on how vibrational frequencies are shifted and intensities modified in the receptor protein environment. Principal component analysis (PCA) suggested that the frequency shifts of C-C stretching, CH(3) umbrella, C = O stretching and CH(3) stretching modes have a significant effect on odor quality. In fact, the frequency shifts of the C-C stretching and C = O stretching modes, as well as CH(3) umbrella and CH(3) symmetric stretching modes, exhibit different behaviors in the PCA loadings plot. A large frequency shift in the CH(3) symmetric stretching mode is associated with the sweet-roasted odor category and separates this from the acid odor category. A large frequency shift of the C-C stretching mode describes the roasted and oily-popcorn odor categories, and separates these from the buttery and acid odor categories.
Method for ambiguity resolution in range-Doppler measurements
NASA Technical Reports Server (NTRS)
Heymsfield, Gerald M. (Inventor); Miller, Lee S. (Inventor)
1994-01-01
A method for resolving range and Doppler target ambiguities when the target has substantial range or has a high relative velocity in which a first signal is generated and a second signal is also generated which is coherent with the first signal but at a slightly different frequency such that there exists a difference in frequency between these two signals of Delta f(sub t). The first and second signals are converted into a dual-frequency pulsed signal, amplified, and the dual-frequency pulsed signal is transmitted towards a target. A reflected dual-frequency signal is received from the target, amplified, and changed to an intermediate dual-frequency signal. The intermediate dual-frequency signal is amplified, with extracting of a shifted difference frequency Delta f(sub r) from the amplified intermediate dual-frequency signal done by a nonlinear detector. The final step is generating two quadrature signals from the difference frequency Delta f(sub t) and the shifted difference frequency Delta f(sub r) and processing the two quadrature signals to determine range and Doppler information of the target.
Research and development for a ground-based hydrogen-maser system
NASA Technical Reports Server (NTRS)
1972-01-01
The results of a joint experiment aimed primarily at the determination of the frequency of the H(1) hyperfine transition are reported. The transition frequency value for Cs-133 hyperfine transition is found. The result is the mean of two independent evaluations against the cesium reference, which differ by 0.002 Hz. The one-sigma uncertainty of the value nu sub H is also estimated to be 0.002 Hz. One evaluation is based on wall shift experiments at Harvard University; the other is a result of new wall shift measurement using many storage bulbs of different sizes at the National Bureau of Standards. The experimental procedures and the applied corrections are described. Results for the wall shift and for the frequency of hydrogen are compared with previously published values, and error limits of the experiments are discussed.
Ballestra, Alberto; Somà, Aurelio; Pavanello, Renato
2008-02-06
The dynamic characterization of a set of gold micro beams by electrostatic excitation in presence of residual stress gradient has been studied experimentally. A method to determine the micro-cantilever residual stress gradient by measuring the deflection and curvature and then identifying the residual stress model by means of frequency shift behaviour is presented. A comparison with different numerical FEM models and experimental results has been carried out, introducing in the model the residual stress of the structures, responsible for an initial upward curvature. Dynamic spectrum data are measured via optical interferometry and experimental frequency shift curves are obtained by increasing the dc voltage applied to the specimens. A good correspondence is pointed out between measures and numerical models so that the residual stress effect can be evaluated for different configurations.
Ballestra, Alberto; Somà, Aurelio; Pavanello, Renato
2008-01-01
The dynamic characterization of a set of gold micro beams by electrostatic excitation in presence of residual stress gradient has been studied experimentally. A method to determine the micro-cantilever residual stress gradient by measuring the deflection and curvature and then identifying the residual stress model by means of frequency shift behaviour is presented. A comparison with different numerical FEM models and experimental results has been carried out, introducing in the model the residual stress of the structures, responsible for an initial upward curvature. Dynamic spectrum data are measured via optical interferometry and experimental frequency shift curves are obtained by increasing the dc voltage applied to the specimens. A good correspondence is pointed out between measures and numerical models so that the residual stress effect can be evaluated for different configurations. PMID:27879733
Experimental investigation on frequency shifting of imperfect adhesively bonded pipe joints
NASA Astrophysics Data System (ADS)
Haiyam, F. N.; Hilmy, I.; Sulaeman, E.; Firdaus, T.; Adesta, E. Y. T.
2018-01-01
Inspection tests for any manufactured structure are compulsory in order to detect the existence of damage.It is to ensure the product integrity, reliability and to avoid further catastrophic failure. In this research, modal analysis was utilized to detect structural damage as one of the Non Destructive Testing (NDT) methods. Comparing the vibration signal of a healthy structure with a non-healthy signal was performed. A modal analysis of an adhesively bonded pipe joint was investigated with a healthy joint as a reference. The damage joint was engineered by inserting a nylon fiber, which act as an impurity at adhesive region. The impact test using hammer was utilized in this research. Identification of shifting frequency of a free supported and clamped pipe joint was performed.It was found that shifting frequency occurred to the lower side by 5%.
Varied absorption peaks of dual-band metamaterial absorber analysis by using reflection theory
NASA Astrophysics Data System (ADS)
Xiong, Han; Yu, Yan-Tao; Tang, Ming-Chun; Chen, Shi-Yong; Liu, Dan-Ping; Ou, Xiang; Zeng, Hao
2016-03-01
Cross-resonator metamaterial absorbers (MMA) have been widely investigated from microwave to optical frequencies. However, only part of the factors influencing the absorption properties were analyzed in previous works at the same time. In order to completely understand how the spacer thickness, dielectric parameter and incidence angle affect the absorption properties of the dual-band MMA, two sets of simulation were performed. It was found that with increasing incident angles, the low-frequency absorption peak showed a blue shift, while the high-frequency absorption peaks showed a red shift. However, with the increase in spacer thickness, both of the absorption peaks showed a red shift. By using the reflection theory expressions, the physical mechanism of the cross-resonator MMA was well explained. This method provides an effective way to analyze multi-band absorber in technology.
High-speed optical coherence tomography using fiberoptic acousto-optic phase modulation
NASA Astrophysics Data System (ADS)
Xie, Tuqiang; Wang, Zhenguo; Pan, Yingtian
2003-12-01
We report a new rapid-scanning optical delay device suitable for high-speed optical coherence tomography (OCT) in which an acousto-optic modulator (AOM) is used to independently modulate the Doppler frequency shift of the reference light beam for optical heterodyne detection. Experimental results show that the fluctuation of the measured Doppler frequency shift is less than +/-0.2% over 95% duty cycle of OCT imaging, thus allowing for enhanced signal-to-noise ratio of optical heterodyne detection. The increased Doppler frequency shift by AOM also permits complete envelop demodulation without the compromise of reducing axial resolution; if used with a resonant rapid-scanning optical delay, it will permit high-performance real-time OCT imaging. Potentially, this new rapid-scanning optical delay device will improve the performance of high-speed Doppler OCT techniques.
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10{sup -17} Level
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westergaard, P. G.; Lodewyck, J.; Lecallier, A.
2011-05-27
We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5x10{sup -17} after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice relatedmore » perturbations will not affect the clock accuracy down to the 10{sup -17} level, even for lattices as deep as 150 recoil energies.« less
What is the Temporal Analog of Reflection and Refraction of Optical Beams?
Plansinis, B W; Donaldson, W R; Agrawal, G P
2015-10-30
It is shown numerically and analytically that when an optical pulse approaches a moving temporal boundary across which the refractive index changes, it undergoes a temporal equivalent of reflection and refraction of optical beams at a spatial boundary. The main difference is that the role of angles is played by changes in the frequency. The frequency dependence of the dispersion of the material in which the pulse is propagating plays a fundamental role in determining the frequency shifts experienced by the reflected and refracted pulses. Our analytic expressions for these frequency shifts allow us to find the condition under which an analog of total internal reflection may occur at the temporal boundary.
Harnsberger, James D.; Svirsky, Mario A.; Kaiser, Adam R.; Pisoni, David B.; Wright, Richard; Meyer, Ted A.
2012-01-01
Cochlear implant (CI) users differ in their ability to perceive and recognize speech sounds. Two possible reasons for such individual differences may lie in their ability to discriminate formant frequencies or to adapt to the spectrally shifted information presented by cochlear implants, a basalward shift related to the implant’s depth of insertion in the cochlea. In the present study, we examined these two alternatives using a method-of-adjustment (MOA) procedure with 330 synthetic vowel stimuli varying in F1 and F2 that were arranged in a two-dimensional grid. Subjects were asked to label the synthetic stimuli that matched ten monophthongal vowels in visually presented words. Subjects then provided goodness ratings for the stimuli they had chosen. The subjects’ responses to all ten vowels were used to construct individual perceptual “vowel spaces.” If CI users fail to adapt completely to the basalward spectral shift, then the formant frequencies of their vowel categories should be shifted lower in both F1 and F2. However, with one exception, no systematic shifts were observed in the vowel spaces of CI users. Instead, the vowel spaces differed from one another in the relative size of their vowel categories. The results suggest that differences in formant frequency discrimination may account for the individual differences in vowel perception observed in cochlear implant users. PMID:11386565
NASA Technical Reports Server (NTRS)
Deboo, G. J.; Hedlund, R. C. (Inventor)
1973-01-01
An electronic filter is described which simultaneously maintains a constant bandwidth and a constant center frequency gain as the input signal frequency varies, and remains self-tuning to that center frequency over a decade range. The filter utilizes a field effect transistor (FET) as a voltage variable resistance in the bandpass frequency determining circuit. The FET is responsive to a phase detector to achieve self-tuning.
Education-related inequity in healthcare with heterogeneous reporting of health
d’Uva, Teresa Bago; Lindeboom, Maarten; O’Donnell, Owen; van Doorslaer, Eddy
2011-01-01
Summary Reliance on self-rated health to proxy medical need can bias estimation of education-related inequity in healthcare utilization. We correct this bias both by instrumenting self-rated health with objective health indicators and by purging self-rated health of reporting heterogeneity that is identified from health vignettes. Using data on elderly Europeans, we find that instrumenting self-rated health shifts the distribution of visits to a doctor in the direction of inequality favouring the better educated. There is a further, and typically larger, shift in the same direction when correction is made for the tendency of the better educated to rate their health more negatively. PMID:21938140
The effects of a hot outer atmosphere on acoustic-gravity waves
NASA Technical Reports Server (NTRS)
Hindman, Bradley W.; Zweibel, Ellen G.
1994-01-01
We examine the effects of a hot chromosphere and corona on acoustic-gravity waves in the Sun. We use a simple solar model consisting of a neutrally stable polytrope smoothly matched to an isothermal chromosphere or corona. The temperature of the isothermal region is higher than the minimum temperature of the model. We ignore sphericity, magnetic fields, changes in the gravitational potential, and nonadiabatic effects. We find a family of atmospheric g-modes whose cavity is formed by the extremum in the buoyancy frequency at the transition region. The f-mode is the zero-order member of this family. For large values of the harmonic degree l, f-mode frequencies are below the classic f-mode frequency, mu=(gk)(exp 1/2), whereas at small values of l, the f-mode is identical to the classical f-mode solution. We also find a family of g-modes residing in the low chromosphere. Frequency shifts of p-modes can be positive or negative. When the frequency is less than the acoustic cutoff frequency of the upper isothermal atmsophere, the frequency of the upper isothermal atmosphere, the frequency shift is negative, but when the frequency is above this cutoff, the shifts can be positive. High-frequency acoustic waves which are not reflected by the photospheric cutoff are reflected at the corona by the high sound speed for moderate values of l and v. This result is independent of the solar model as long as the corona is very hot. The data are inconsistent with this result, and reasons for this discrepancy are discussed.
Power allocation and range performance considerations for a dual-frequency EBPSK/MPPSK system
NASA Astrophysics Data System (ADS)
Yao, Yu; Wu, Lenan; Zhao, Junhui
2017-12-01
Extended binary phase shift keying/M-ary position phase shift keying (EBPSK/MPPSK)-MODEM provides radar and communication functions on a single hardware platform with a single waveform. However, its range estimation accuracy is worse than continuous-wave (CW) radar because of the imbalance of power in two carrier frequencies. In this article, the power allocation method for dual-frequency EBPSK/MPPSK modulated systems is presented. The power of two signal transmitters is adequately allocated to ensure that the power in two carrier frequencies is equal. The power allocation ratios for two types of modulation systems are obtained. Moreover, considerations regarding the range of operation of the dual-frequency system are analysed. In addition to theoretical considerations, computer simulations are provided to illustrate the performance.
NASA Astrophysics Data System (ADS)
Li, Mao; Ishihara, Shinsuke; Ji, Qingmin; Akada, Misaho; Hill, Jonathan P.; Ariga, Katsuhiko
2012-10-01
Current nanotechnology based on top-down nanofabrication may encounter a variety of drawbacks in the near future so that development of alternative methods, including the so-called bottom-up approach, has attracted considerable attention. However, the bottom-up strategy, which often relies on spontaneous self-assembly, might be inefficient in the development of the requisite functional materials and systems. Therefore, assembly processes controlled by external stimuli might be a plausible strategy for the development of bottom-up nanotechnology. In this review, we demonstrate a paradigm shift from self-assembly to commanded assembly by describing several examples of assemblies of typical functional molecules, i.e. porphyrins and fullerenes. In the first section, we describe recent progress in the design and study of self-assembled and co-assembled supramolecular architectures of porphyrins and fullerenes. Then, we show examples of assembly induced by external stimuli. We emphasize the paradigm shift from self-assembly to commanded assembly by describing the recently developed electrochemical-coupling layer-by-layer (ECC-LbL) methodology.
Kleiman, Tali; Trope, Yaacov; Amodio, David M
2016-12-01
Self-control in one's food choices often depends on the regulation of attention toward healthy choices and away from temptations. We tested whether selective attention to food cues can be modulated by a newly developed proactive self-control mechanism-control readiness-whereby control activated in one domain can facilitate control in another domain. In two studies, we elicited the activation of control using a color-naming Stroop task and tested its effect on attention to food cues in a subsequent, unrelated task. We found that control readiness modulates both overt attention, which involves shifts in eye gaze (Study 1), and covert attention, which involves shift in mental attention without shifting in eye gaze (Study 2). We further demonstrated that individuals for whom tempting food cues signal a self-control problem (operationalized by relatively higher BMI) were especially likely to benefit from control readiness. We discuss the theoretical contributions of the control readiness model and the implications of our findings for enhancing proactive self-control to overcome temptation in food choices. Copyright © 2016 Elsevier Inc. All rights reserved.
Relationship between shift work schedule and self-reported sleep quality in Chinese employees.
Ma, Yifei; Wei, Fu; Nie, Guanghui; Zhang, Li'e; Qin, Jian; Peng, Suwan; Xiong, Feng; Zhang, Zhiyong; Yang, Xiaobo; Peng, Xiaowu; Wang, Mingjun; Zou, Yunfeng
2018-02-01
Few studies have reported on the effects of fixed and rotating shift systems on the prevalence of sleep disturbance. Thus, in this study, the relationships between different work schedules and sleep disturbance in Chinese workers were investigated. A total of 2180 workers aged 19-65 years responded to the self-report questionnaire on shift work schedule (fixed day-shift, fixed night-shift, two-shift or three-shift system), working hours a day, and working days a week, physical effort, subjective sleep quality and subjective mental state. It was found that the rotating shift workers, namely, two- and three-shift workers, exhibited higher risks of sleep disturbance than with the fixed day-shift workers did (OR 1.37; 95% CI 1.07to 1.74; and OR 2.19; 95% CI 1.52 to 3.15, respectively). The risk was particularly high among two- or three-shift workers who worked more than 8 hours a day or more than 5 days a week and among three-shift workers who reported both light and heavy physical effort at work. Moreover, the two- and three-shift workers (rotating shift workers) suffered from poorer sleep quality than the fixed night shift workers did (OR 1.84; 95% CI 1.01 to 3.32; and OR 2.94; 95% CI 1.53 to 5.64, respectively). Consequently, rotating shift work (two- and three-shift work) is a risk factor for sleep disturbance, and the fixed work rhythm may contribute to the quality of sleep.
Fernandez, Marta; Espinosa, Hugo G; Thiel, David V; Arrinda, Amaia
2018-01-01
The interaction of body-worn antennas with the human body causes a significant decrease in antenna efficiency and a shift in resonant frequency. A resonant slot in a small conductive box placed on the body has been shown to reduce these effects. The specific absorption rate is less than international health standards for most wearable antennas due to small transmitter power. This paper reports the linear relationship between power absorbed by biological tissues at different locations on the body and radiation efficiency based on numerical modeling (r = 0.99). While the -10 dB bandwidth of the antenna remained constant and equal to 12.5%, the maximum frequency shift occurred when the antenna was close to the elbow (6.61%) and on the thigh (5.86%). The smallest change was found on the torso (4.21%). Participants with body-mass index (BMI) between 17 and 29 kg/m 2 took part in experimental measurements, where the maximum frequency shift was 2.51%. Measurements showed better agreement with simulations on the upper arm. These experimental results demonstrate that the BMI for each individual had little effect on the performance of the antenna. Bioelectromagnetics. 39:25-34, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
FBG wavelength demodulation based on a radio frequency optical true time delay method.
Wang, Jin; Zhu, Wanshan; Ma, Chenyuan; Xu, Tong
2018-06-01
A new fiber Bragg grating (FBG) wavelength shift demodulation method based on optical true time delay microwave phase detection is proposed. We used a microwave photonic link (MPL) to transport a radio frequency (RF) signal over a dispersion compensation fiber (DCF). The wavelength shift of the FBG will cause the time delay change of the optical carrier that propagates in an optical fiber with chromatic dispersion, which will result in the variation of the RF signal phase. A long DCF was adopted to enlarge the RF signal phase variation. An IQ mixer was used to measure the RF phase variation of the RF signal propagating in the MPL, and the wavelength shift of the FBG can be obtained by the measured RF signal phase variation. The experimental results showed that the wavelength shift measurement resolution is 2 pm when the group velocity dispersion of the DCF is 79.5 ps/nm and the frequency of the RF signal is 18 GHz. The demodulation time is as short as 0.1 ms. The measurement resolution can be improved simply by using a higher frequency of the RF signal and a longer DCF or larger chromatic dispersion value of the DCF.
Sayal, Kapil; Townsend, Ellen
2016-01-01
This study investigated the relationship between experiential avoidance, coping and the recency and frequency of self-harm, in a community sample (N = 1332, aged 16–69 years). Participants completed online, self-report measures assessing self-harm, momentary affect, experiential avoidance and coping in response to a recent stressor. Participants who had self-harmed reported significantly higher levels of experiential avoidance and avoidance coping, as well as lower levels of approach, reappraisal and emotional regulation coping, than those with no self-harm history. Moreover, more recent self-harm was associated with lower endorsement of approach, reappraisal and emotion regulation coping, and also higher levels of both avoidance coping and experiential avoidance. Higher experiential avoidance and avoidance coping also predicted increased lifetime frequency of self-harm. Conversely, increased approach and reappraisal coping were associated with a decreased likelihood of high frequency self-harm. Although some of the effects were small, particularly in relation to lifetime frequency of self-harm, overall our results suggest that experiential avoidance tendency may be an important psychological factor underpinning self-harm, regardless of suicidal intent (e.g. including mixed intent, suicidal intent, ambivalence), which is not accounted for in existing models of self-harm. PMID:27442036
Kristensen, Mads Aage Toft; Guassora, Ann Dorrit; Arreskov, Anne Beiter; Waldorff, Frans Boch; Hølge-Hazelton, Bibi
2018-06-22
This paper investigated patients' experiences of disease and self-care as well as perceptions of the general practitioner's role in supporting patients with impaired self-care ability. Qualitative interviews with 13 patients with type 2 diabetes, concurrent chronic diseases, and impaired self-care ability assessed by a general practitioner. We analyzed our data using systematic text condensation. The shifting perspectives model of chronic illness formed the theoretical background for the study. Although most patients experienced challenges in adhering to recommended self-care activities, many had developed additional, personal self-care routines that increased wellbeing. Some patients were conscious of self-care trade-offs, including patients with concurrent mental disorders who were much more attentive to their mental disorder than their somatic diseases. Patients' perspectives on diseases could shift over time and were dominated by emotional considerations such as insisting on leading a normal life or struggling with limitations caused by disease. Most patients found support in the ongoing relationship with the same general practitioner, who was valued as a companion or appreciated as a trustworthy health informant. Patient experiences of self-care may collide with what general practitioners find appropriate in a medical regimen. Health professionals should be aware of patients' prominent and shifting considerations about the emotional aspects of disease. Patients valued the general practitioner's role in self-care support, primarily through the long-term doctor-patient relationship. Therefore, relational continuity should be prioritized in chronic care, especially for patients with impaired self-care ability who often have a highly complex disease burden and situational context. Key points Little is known about the perspectives of disease and self-care in patients with a doctor-assessed impaired ability of self-care. • Although patients knew the prescribed regimen they often prioritized self-care routines that increased well-being at the cost of medical recommendations. • Shifting emotional aspects were prominent in patients' considerations of disease and sustained GPs' use of a patient-centred clinical method when discussing self-care. • Relational continuity with general practitioners was a highly valued support and should be prioritized for patients with impaired self-care.
Zhou, Da-Peng; Li, Wenhai; Chen, Liang; Bao, Xiaoyi
2013-01-31
A distributed optical fiber sensor with the capability of simultaneously measuring temperature and strain is proposed using a large effective area non-zero dispersion shifted fiber (LEAF) with sub-meter spatial resolution. The Brillouin frequency shift is measured using Brillouin optical time-domain analysis (BOTDA) with differential pulse-width pair technique, while the spectrum shift of the Rayleigh backscatter is measured using optical frequency-domain reflectometry (OFDR). These shifts are the functions of both temperature and strain, and can be used as two independent parameters for the discrimination of temperature and strain. A 92 m measurable range with the spatial resolution of 50 cm is demonstrated experimentally, and accuracies of ±1.2 °C in temperature and ±15 με in strain could be achieved.
Interpretation of frequency modulation atomic force microscopy in terms of fractional calculus
NASA Astrophysics Data System (ADS)
Sader, John E.; Jarvis, Suzanne P.
2004-07-01
It is widely recognized that small amplitude frequency modulation atomic force microscopy probes the derivative of the interaction force between tip and sample. For large amplitudes, however, such a physical connection is currently lacking, although it has been observed that the frequency shift presents a quantity intermediate to the interaction force and energy for certain force laws. Here we prove that these observations are a universal property of large amplitude frequency modulation atomic force microscopy, by establishing that the frequency shift is proportional to the half-fractional integral of the force, regardless of the force law. This finding indicates that frequency modulation atomic force microscopy can be interpreted as a fractional differential operator, where the order of the derivative/integral is dictated by the oscillation amplitude. We also establish that the measured frequency shift varies systematically from a probe of the force gradient for small oscillation amplitudes, through to the measurement of a quantity intermediate to the force and energy (the half-fractional integral of the force) for large oscillation amplitudes. This has significant implications to measurement sensitivity, since integrating the force will smooth its behavior, while differentiating it will enhance variations. This highlights the importance in choice of oscillation amplitude when wishing to optimize the sensitivity of force spectroscopy measurements to short-range interactions and consequently imaging with the highest possible resolution.
Single-resonator double-negative metamaterial
Warne, Larry K.; Basilio, Lorena I.; Langston, William L.; Johnson, William A.; Ihlefeld, Jon; Ginn, III, James C.; Clem, Paul G.; Sinclair, Michael B.
2016-06-21
Resonances can be tuned in dielectric resonators in order to construct single-resonator, negative-index metamaterials. For example, high-contrast inclusions in the form of metallic dipoles can be used to shift the first electric resonance down (in frequency) to the first magnetic resonance, or alternatively, air splits can be used to shift the first magnetic resonance up (in frequency) near the first electric resonance. Degenerate dielectric designs become especially useful in infrared- or visible-frequency applications where the resonator sizes associated with the lack of high-permittivity materials can become of sufficient size to enable propagation of higher-order lattice modes in the resulting medium.
Quantum-enhanced spectroscopy with entangled multiphoton states
NASA Astrophysics Data System (ADS)
Dinani, Hossein T.; Gupta, Manish K.; Dowling, Jonathan P.; Berry, Dominic W.
2016-06-01
Traditionally, spectroscopy is performed by examining the position of absorption lines. However, at frequencies near the transition frequency, additional information can be obtained from the phase shift. In this work we consider the information about the transition frequency obtained from both the absorption and the phase shift, as quantified by the Fisher information in an interferometric measurement. We examine the use of multiple single-photon states, NOON states, and numerically optimized states that are entangled and have multiple photons. We find the optimized states that improve over the standard quantum limit set by independent single photons for some atom number densities.
Search for supersolidity in solid 4He using multiple-mode torsional oscillators
Eyal, Anna; Mi, Xiao; Talanov, Artem V.; Reppy, John D.
2016-01-01
In 2004, Kim and Chan (KC) reported a decrease in the period of torsional oscillators (TO) containing samples of solid 4He, as the temperature was lowered below 0.2 K [Kim E, Chan MHW (2004) Science 305(5692):1941–1944]. These unexpected results constituted the first experimental evidence that the long-predicted supersolid state of solid 4He may exist in nature. The KC results were quickly confirmed in a number of other laboratories and created great excitement in the low-temperature condensed-matter community. Since that time, however, it has become clear that the period shifts seen in the early experiments can in large part be explained by an increase in the shear modulus of the 4He solid identified by Day and Beamish [Day J, Beamish J (2007) Nature 450(7171):853–856]. Using multiple-frequency torsional oscillators, we can separate frequency-dependent period shifts arising from changes in the elastic properties of the solid 4He from possible supersolid signals, which are expected to be independent of frequency. We find in our measurements that as the temperature is lowered below 0.2 K, a clear frequency-dependent contribution to the period shift arising from changes in the 4He elastic properties is always present. For all of the cells reported in this paper, however, there is always an additional small frequency-independent contribution to the total period shift, such as would be expected in the case of a transition to a supersolid state. PMID:27222579
Interpreting Quasi-Thermal Effects in Ultrafast Spectroscopy of Hydrogen-Bonded Systems.
Stingel, Ashley M; Petersen, Poul B
2018-03-15
Vibrational excitation of molecules in the condensed phase relaxes through vibrational modes of decreasing energy to ultimately generate an equilibrium state in which the energy is distributed among low-frequency modes. In ultrafast vibrational spectroscopy, changes in the vibrational features of hydrogen-bonded NH and OH stretch modes are typically observed to persist long after these high-frequency vibrations have relaxed. Due to the resemblance to the spectral changes caused by heating the sample, these features are typically described as arising from a hot ground state. However, these spectral features appear on ultrafast time scales that are much too fast to result from a true thermal state, and significant differences between the thermal difference spectrum and the induced quasi-thermal changes in ultrafast spectroscopy are often observed. Here, we examine and directly compare the thermal and quasi-thermal responses of the hydrogen-bonded homodimer of 7-azaindole with temperature-dependent FTIR spectroscopy and ultrafast mid-IR continuum spectroscopy. We find that the thermal difference spectra contain contributions from both dissociation of the hydrogen bonds and from frequency shifts due to changes in the thermal population of low-frequency modes. The transient spectra in ultrafast vibrational spectroscopy are also found to contain two contributions: initial frequency shifts over 2.3 ± 0.11 ps associated with equilibration of the initial excitation, and frequency shifts associated with the excitation of several fingerprint modes, which decay over 21.8 ± 0.11 ps, giving rise to a quasi-thermal response caused by a distribution of fingerprint modes being excited within the sample ensemble. This resembles the thermal frequency shifts due to population changes of low-frequency modes, but not the overall thermal spectrum, which is dominated by features caused by dimer dissociation. These findings provide insight into the changes in the vibrational spectrum from different origins and are important for assigning, analyzing, and comparing features in thermal and ultrafast vibrational spectroscopy of hydrogen-bonded complexes.
Stockman, Andrew; Henning, G Bruce; West, Peter; Rider, Andrew T; Ripamonti, Caterina
2017-08-01
When M- or L-cone-isolating sawtooth waveforms flicker at frequencies between 4 and 13.3 Hz, there is a mean hue shift in the direction of the shallower sawtooth slope. Here, we investigate how this shift depends on the alignment of the first and second harmonics of sawtooth-like waveforms. Below 4 Hz, observers can follow hue variations caused by both harmonics, and reliably match reddish and greenish excursions. At higher frequencies, however, the hue variations appear as chromatic flicker superimposed on a steady light, the mean hue of which varies with second-harmonic alignment. Observers can match this mean hue against a variable-duty-cycle rectangular waveform and, separately, set the alignment at which the mean hue flips between reddish and greenish. The maximum hue shifts were approximately frequency independent and occurred when the peaks or troughs of the first and second harmonics roughly aligned at the visual input-consistent with the hue shift's being caused by an early instantaneous nonlinearity that saturates larger hue excursions. These predictions, however, ignore phase delays introduced within the chromatic pathway between its input and the nonlinearity that produces the hue shifts. If the nonlinearity follows the substantial filtering implied by the chromatic temporal contrast-sensitivity function, phase delays will alter the alignment of the first and second harmonics such that at the nonlinearity, the waveforms that produce the maximum hue shifts might well be those with the largest differences in rising and falling slopes-consistent with the hue shift's being caused by a central nonlinearity that limits the rate of hue change.
Pearce, Jeffrey D.; Craven, Timothy E.; Edwards, Matthew S.; Corriere, Matthew A.; Crutchley, Teresa A.; Fleming, Shawn H.; Hansen, Kimberley J.
2010-01-01
Background Atherosclerotic renovascular disease is associated with an increased risk of cardiovascular disease (CVD) events. This study examines associations between Doppler-derived parameters from the renal artery and renal parenchyma and all-cause mortality and fatal and nonfatal CVD events in a cohort of elderly Americans. Study Design Cohort study. Setting A subset of participants from the Cardiovascular Health Study (CHS). Through an ancillary study, 870 (70% recruitment) Forsyth County, NC, CHS participants consented to undergo renal duplex sonography to define the prevalence of renovascular disease in the elderly, resulting in 726 (36% men; mean age, 77 years) technically adequate complete studies included in this investigation. Predictor Renal duplex sonography–derived Doppler signals from the main renal arteries and renal parenchyma. Spectral analysis from Doppler-shifted frequencies and angle of insonation were used to estimate renal artery peak systolic and end diastolic velocity (both in meters per second). Color Doppler was used to identify the corticomedullary junction. Using a 3-mm Doppler sample, the parenchymal peak systolic and end diastolic frequency shift (both in kilohertz) were obtained. Resistive index was calculated as (1 – [end diastolic frequency shift/peak systolic frequency shift]) using Doppler samples from the hilar arteries of the left or right kidney with the higher main renal artery peak systolic velocity. Outcomes & Measurements Proportional hazard regression analysis was used to determine associations between renal duplex sonography–derived Doppler signals and CVD events and all-cause mortality adjusted for accepted cardiovascular risk factors. Index CVD outcomes were defined as coronary events (angina, myocardial infarction, and coronary artery bypass grafting/percutaneous coronary intervention), cerebrovascular events (stroke or transient ischemic attack), and any CVD event (angina, congestive heart failure, myocardial infarction, stroke, transient ischemic attack, and coronary artery bypass grafting [CABG]/percutaneous transluminal coronary intervention [PTCI]). Results During follow-up, 221 deaths (31%), 229 CVD events (32%), 122 coronary events (17%), and 92 cerebrovascular events (13%) were observed. Renal duplex sonography–derived Doppler signals from the renal parenchyma were associated independently with all-cause mortality and CVD outcomes. In particular, increased parenchymal end diastolic frequency shift was associated significantly with any CVD event (HR, 0.73; 95% CI, 0.62-0.87; P < 0.001). Marginally significant associations were observed between increases in parenchymal end diastolic frequency shift and decreased risk of death (HR, 0.86; 95% CI, 0.73-1.00; P = 0.06) and decreased risk of cerebrovascular events (HR, 0.78; 95% CI, 0.61-1.01; P = 0.06). Parenchymal end diastolic frequency shift was not significantly predictive of coronary events (HR, 0.84; 95% CI, 0.67-1.06; P = 0.1). Limitations CHS participants showed a “healthy cohort” effect that may underestimate the rate of CVD events in the general population. Conclusion Renal duplex sonographic Doppler signals from the renal parenchyma showed significant associations with subsequent CVD events after controlling for other significant risk factors. In particular, a standard deviation increase in parenchymal end diastolic frequency shift was associated with 27% risk reduction in any CVD event. PMID:20116688
Laser frequency stabilization by light shift of optical-magnetic double resonances
NASA Astrophysics Data System (ADS)
Zhan, Yuanzhi; Peng, Xiang; Lin, Zaisheng; Gong, Wei; Guo, Hong
2015-05-01
This work adopts the light shift of optical-magnetic double resonance frequency in metastable-state 4He atoms to lock the laser center frequency to the magic point. At this magic frequency, both the left-circularly and right-circularly optical pumping processes will give the same value of optical-magnetic double resonance. With this method and after locking, experimental results show that the laser frequency fluctuation is dramatically reduced to 2.79 MHz in 3600 seconds, comparing with 34.1 MHz drift in the free running mode. In application, with the locked magic laser frequency, the heading error for laser pumped 4He magnetometer can be eliminated much. The National Science Fund for Distinguished Young Scholars of China (Grant No. 61225003), the National Natural Science Foundation of China (Grant No. 61101081), and the National Hi-Tech Research and Development (863) Program.
A comparative study on simulation performances of rigid and bendable SAW for gas sensor
NASA Astrophysics Data System (ADS)
Sidek, Fatini; Arsat, Rashidah; Ibrahim, Rafidah; Idris, Aizzat Ayuni Mohad; Johari, Zaharah; Ling, Leow Pei
2017-03-01
Flexible Surface Acoustic Wave (SAW) devices are very promising technology for various applications that offers excellent flexibility, low in cost and light weight. In this paper, a SAW gas sensor is designed and simulated using COMSOL Multiphysics to investigate the degree of bending effect on the frequency and displacement. The investigations were conducted onto SAW gas sensor as rigid and two different bends direction; bend-in (concave) and bend-out (convex). The operating frequency of the SAW sensor were found to be at the range of 80-200 MHz. The frequency shift of the sensor were obtained after exposing the polyisobutylene (PIB) to the dichloromethane DCM gas which will change the density of sensing layer. From the simulation, it is shown that resonance frequency range of 189MHz for the rigid substrate with displacement of 0.706 nm. Notably, the bending degree of h range from 0.2 µm to 1.25 µm exhibits reduction for displacement and frequency. The higher frequency of bend-out (convex) design achieve is 1.8945 MHz with displacement of 0.68 nm at curve of h= 0.2 µm, Improvement have been observed for the frequency shift of 14 Hz and sensitivity of 1324.24. It shows that the sensor is more sensitive to detect the gas. The evaluation of device bending effect on the eigenfrequency, displacement and frequency shift provide ways to enhance the sensitivity of the gas sensor and expand its possibility of realizing their benefit particularly for sensing device enhancement.
Kuznetsova, G D; Gabova, A V; Lazarev, I E; Obukhov, Iu V; Obukhov, K Iu; Morozov, A A; Kulikov, M A; Shchatskova, A B; Vasil'eva, O N; Tomilovskaia, E S
2015-01-01
Frequency-temporal electroencephalogram (EEG) reactions to hypogravity were studied in 7 male subjects at the age of 20 to 27 years. The experiment was conducted using dry immersion (DI) as the best known method of simulating the space microgravity effects on the Earth. This hypogravity model reproduces hypokinesia, i.e. the weight-bearing and mechanic load removal, which is typical of microgravity. EEG was recorded by Neuroscan-2 (Compumedics) before the experiment (baseline data) and at the end of day 2 in DI. Comparative analysis of the EEG frequency-temporal structure was performed with the use of 2 techniques: Fourier transform and modified wavelet analysis. The Fourier transform elicited that after 2 days in DI the main shifts occurring to the EEG spectral composition are a decline in the alpha power and a slight though reliable growth of theta power. Similar frequency shifts were detected in the same records analyzed using the wavelet transform. According to wavelet analysis, during DI shifts in EEG frequency spectrum are accompanied by frequency desorganization of the EEG dominant rhythm and gross impairment of total stability of the electrical activity with time. Wavelet transform provides an opportunity to quantify changes in the frequency-temporal structure of the electrical activity of the brain. Quantitative evidence of frequency desorganization and temporal instability of EEG wavelet spectrograms may be the key to the understanding of mechanisms that drive functional disorders in the brain cortex in the conditions of hypogravity.
The perceptual enhancement of tones by frequency shifts.
Demany, Laurent; Carcagno, Samuele; Semal, Catherine
2013-04-01
In a chord of pure tones with a flat spectral profile, one tone can be perceptually enhanced relative to the other tones by the previous presentation of a slightly different chord. "Intensity enhancement" (IE) is obtained when the component tones of the two chords have the same frequencies, but in the first chord the target of enhancement is attenuated relative to the other tones. "Frequency enhancement" (FE) is obtained when both chords have a flat spectral profile, but the target of enhancement shifts in frequency from the first to the second chord. We report here an experiment in which IE and FE were measured using a task requiring the listener to indicate whether or not the second chord included a tone identical to a subsequent probe tone. The results showed that a global attenuation of the first chord relative to the second chord disrupted IE more than FE. This suggests that the mechanisms of IE and FE are not the same. In accordance with this suggestion, computations of the auditory excitation patterns produced by the chords indicate that the mechanism of IE is not sufficient to explain FE for small frequency shifts. Copyright © 2013 Elsevier B.V. All rights reserved.
Higher-order differential phase shift keyed modulation
NASA Astrophysics Data System (ADS)
Vanalphen, Deborah K.; Lindsey, William C.
1994-02-01
Advanced modulation/demodulation techniques which are robust in the presence of phase and frequency uncertainties continue to be of interest to communication engineers. We are particularly interested in techniques which accommodate slow channel phase and frequency variations with minimal performance degradation and which alleviate the need for phase and frequency tracking loops in the receiver. We investigate the performance sensitivity to frequency offsets of a modulation technique known as binary Double Differential Phase Shift Keying (DDPSK) and compare it to that of classical binary Differential Phase Shift Keying (DPSK). We also generalize our analytical results to include n(sup -th) order, M-ary DPSK. The DDPSK (n = 2) technique was first introduced in the Russian literature circa 1972 and was studied more thoroughly in the late 1970's by Pent and Okunev. Here, we present an expression for the symbol error probability that is easy to derive and to evaluate numerically. We also present graphical results that establish when, as a function of signal energy-to-noise ratio and normalized frequency offset, binary DDPSK is preferable to binary DPSK with respect to performance in additive white Gaussian noise. Finally, we provide insight into the optimum receiver from a detection theory viewpoint.
Paparo, M.; Benko, J. M.; Hareter, M.; ...
2016-06-17
A sequence search method was developed for searching for regular frequency spacing in δ Scuti stars by visual inspection (VI) and algorithmic search. The sample contains 90 δ Scuti stars observed by CoRoT. An example is given to represent the VI. The algorithm (SSA) is described in detail. The data treatment of the CoRoT light curves, the criteria for frequency filtering, and the spacings derived by two methods (i.e., three approaches: VI, SSA, and FT) are given for each target. Echelle diagrams are presented for 77 targets for which at least one sequence of regular spacing was identified. Comparing the spacing and the shifts between pairs of echelle ridges revealed that at least one pair of echelle ridges is shifted to midway between the spacing for 22 stars. The estimated rotational frequencies compared to the shifts revealed rotationally split doublets, triplets, and multiplets not only for single frequencies, but for the complete echelle ridges in 31 δ Scuti stars. Furthermore, using several possible assumptions for the origin of the spacings, we derived the large separation (more » $${\\rm{\\Delta }}\
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paparo, M.; Benko, J. M.; Hareter, M.
A sequence search method was developed for searching for regular frequency spacing in δ Scuti stars by visual inspection (VI) and algorithmic search. The sample contains 90 δ Scuti stars observed by CoRoT. An example is given to represent the VI. The algorithm (SSA) is described in detail. The data treatment of the CoRoT light curves, the criteria for frequency filtering, and the spacings derived by two methods (i.e., three approaches: VI, SSA, and FT) are given for each target. Echelle diagrams are presented for 77 targets for which at least one sequence of regular spacing was identified. Comparing the spacing and the shifts between pairs of echelle ridges revealed that at least one pair of echelle ridges is shifted to midway between the spacing for 22 stars. The estimated rotational frequencies compared to the shifts revealed rotationally split doublets, triplets, and multiplets not only for single frequencies, but for the complete echelle ridges in 31 δ Scuti stars. Furthermore, using several possible assumptions for the origin of the spacings, we derived the large separation (more » $${\\rm{\\Delta }}\
Seven, Yasin B; Mantilla, Carlos B; Zhan, Wen-Zhi; Sieck, Gary C
2013-01-15
We hypothesized that a shift in diaphragm muscle (DIAm) EMG power spectral density (PSD) to higher frequencies reflects recruitment of more fatigable fast-twitch motor units and motor unit recruitment is reflected by EMG non-stationarity. DIAm EMG was recorded in anesthetized rats during eupnea, hypoxia-hypercapnia (10% O(2)-5% CO(2)), airway occlusion, and sneezing (maximal DIAm force). Although power in all frequency bands increased progressively across motor behaviors, PSD centroid frequency increased only during sneezing (p<0.05). The non-stationary period at the onset of EMG activity ranged from ∼80 ms during airway occlusion to ∼150 ms during eupnea. Within the initial non-stationary period of EMG activity 80-95% of motor units were recruited during different motor behaviors. Motor units augmented their discharge frequencies progressively beyond the non-stationary period; yet, EMG signal became stationary. In conclusion, non-stationarity of DIAm EMG reflects the period of motor unit recruitment, while a shift in the PSD towards higher frequencies reflects recruitment of more fatigable fast-twitch motor units. Copyright © 2012 Elsevier B.V. All rights reserved.
Theoretical Study of Infrared and Raman Spectra of Hydrated Magnesium Sulfate Salts
NASA Technical Reports Server (NTRS)
Chaban, Galina M.; Huo, Winifred M.; Lee, Timothy J.; Kwak, Dochan (Technical Monitor)
2002-01-01
Harmonic and anharmonic vibrational frequencies, as well as infrared and Raman intensities, are calculated for MgSO4.nH20 (n=1-3). Electronic structure theory at the second order Moller-Plesset perturbation theory (MP2) level with a triple-zeta + polarization (TZP) basis set is used to determine the geometry, properties, and vibrational spectra of pure and hydrated MgSO4 salts. The direct vibrational self-consistent field (VSCF) method and its correlation corrected (CC-VSCF) extension are used to determine anharmonic corrections to vibrational frequencies and intensities for the pure MgSO4 and its complex with one water molecule. Very significant differences are found between vibrational of water molecules in complexes with MgSO4 and pure water. Some of the O-H stretching frequencies are shifted to the red very significantly (by up to 1500-2000/cm) upon complexation with magnesium sulfate. They should be observed between 1700 and 3000/cm in a region very different from the corresponding O-H stretch frequency region of pure water (3700-3800/cm). In addition, the SO2 stretching vibrations are found at lower frequency regions than the water vibrations. They can serve as unique identifiers for the presence of sulfate salts. The predicted infrared and Raman spectra should be of valuable help in the design of future missions and analysis of observed data from the ice surface of Jupiter's moon Europa that possibly contains hydrated MgSO4 salts.
Passive Wearable Skin Patch Sensor Measures Limb Hemodynamics Based on Electromagnetic Resonance.
Cluff, Kim; Becker, Ryan; Jayakumar, Balakumar; Han, Kiyun; Condon, Ernie; Dudley, Kenneth; Szatkowski, George; Pipinos, Iraklis I; Amick, Ryan Z; Patterson, Jeremy
2018-04-01
The objectives of this study were to design and develop an open-circuit electromagnetic resonant skin patch sensor, characterize the fluid volume and resonant frequency relationship, and investigate the sensor's ability to measure limb hemodynamics and pulse volume waveform features. The skin patch was designed from an open-circuit electromagnetic resonant sensor comprised of a single baseline trace of copper configured into a square planar spiral which had a self-resonating response when excited by an external radio frequency sweep. Using a human arm phantom with a realistic vascular network, the sensor's performance to measure limb hemodynamics was evaluated. The sensor was able to measure pulsatile blood flow which registered as shifts in the sensor's resonant frequencies. The time-varying waveform pattern of the resonant frequency displayed a systolic upstroke, a systolic peak, a dicrotic notch, and a diastolic down stroke. The resonant frequency waveform features and peak systolic time were validated against ultrasound pulse wave Doppler. A statistical correlation analysis revealed a strong correlation () between the resonant sensor peak systolic time and the pulse wave Doppler peak systolic time. The sensor was able to detect pulsatile flow, identify hemodynamic waveform features, and measure heart rate with 98% accuracy. The open-circuit resonant sensor design leverages the architecture of a thin planar spiral which is passive (does not require batteries), robust and lightweight (does not have electrical components or electrical connections), and may be able to wirelessly monitor cardiovascular health and limb hemodynamics.
Bahadori, Mohammadkarim; Teymourzadeh, Ehsan; Ravangard, Ramin; Nasiri, Ali; Raadabadi, Mehdi; Alimohammadzadeh, Khalil
2016-01-01
Introduction Given the competitive nature of the health market and the multiplicity of factors that may contribute towards patient’s choices of a hospital, patients’ needs and preferences for a hospital must be considered in the planning and decision making of hospitals and health care organizations. This study aimed to identify the factors that contribute to patient’s choices of a clinic and the importance of each factor. Methods A mixed-method approach was used to collect quantitative and qualitative data in two phases. The study was conducted in a hospital clinic in 2014. Qualitative data were collected by face-to-face semi-structured interviews of a sample of 22 managers and heads of outpatient wards. The self-administered questionnaire designed for this study collected quantitative data from a stratified random sample of 381 patients referred to this clinic. The qualitative data were analyzed by a system of coding, while parametrical statistical analyses were conducted to analyze the quantitative data using the independent-samples t-test and ANOVA in SPSS software, version 21.0. Results The qualitative data indicated that there were 21 factors that may contribute to patient’s choices of a clinic, and these factors were classified into six categories, i.e., facilities and physical assets, physicians and employees, location and place, services, price, and promotion. Among the 16 questions studied in the quantitative questionnaire, the highest and lowest means were related to “appropriate clinic environment” (2.47 ± 0.58) and “advertising through TV and radio, the Internet, newspapers, etc.” (1.77 ± 0.75), respectively. There were significant associations between “having experienced and responsive personnel, including physicians and employees” and the patient’s gender and frequency of referrals, between “belonging to the Armed Forces” and the patient’s age and frequency of referrals, between “advertising through TV and radio, the Internet, newspapers, etc.” and shifts and frequency of referrals, between “inadequate facilities and poor quality of services provided in other health care organizations of the Armed Forces” and “adornment and good behavior of staff” and shifts (p < 0.05). Conclusion The most significant contributing factors to attract patients were the “physicians and employees,” and “the clinic’s environment.” Therefore, it is essential for clinic managers and heads of outpatient wards to focus on and strengthen these two factors. Also, since the means of the factors were better in the morning shift, the employees should perform their duties properly and consistently in all shifts. PMID:27382448
Lou, Hans C
2012-02-01
Self-awareness is a pivotal component of any conscious experience and conscious self-regulation of behaviour. A paralimbic network is active, specific and causal in self-awareness. Its regions interact by gamma synchrony. Gamma synchrony develops throughout infancy, childhood and adolescence into adulthood and is regulated by dopamine and other neurotransmitters via GABA interneurons. Major derailments of this network and self-awareness occur in developmental disorders of conscious self-regulation like autism, attention deficit hyperactivity disorder (ADHD) and schizophrenia. Recent research on conscious experience is no longer limited to the study of neural 'correlations' but is increasingly lending itself to the study of causality. This paradigm shift opens new perspectives for understanding the neural mechanisms of the developing self and the causal effects of their disturbance in developmental disorders. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.
[Intention for self-change across the life span: Focusing on concern about self-change].
Chishima, Yuta
2016-06-01
The purpose of the present study was to examine intention for self-change across the life span using measures of self-esteem, frequency of self-reflection, and concern about self-change. We hypothesized that: (a) Intention for self-change decreases with age because of increased self-esteem, decreased self-reflection and concern about self-change, and (b) Associations among self-esteem, frequency of self-reflection, and intention for self-change are mediated by concern about self-change. Participants (N = 997; age range, 15 to 69 yrs) completed an internet survey. ANOVA results suggested that intention for self-change, concern about self-change, and frequency of self-reflection decreased with age, and that self-esteem-scores increased with age. Simultaneous analysis of multiple age groups showed that for all groups of low self-esteem and frequent self-reflection promoted intention for self-change and that there were significant mediating effects for concern about self-change. Therefore, these findings supported out research hypotheses.
Remembering everyday experience through the prism of self-esteem.
Christensen, Tamlin Conner; Wood, Joanne V; Barrett, Lisa Feldman
2003-01-01
Two studies examined whether global self-esteem was associated with bias in memory for autobiographical experience. For 7 days, participants described specific events and made ratings of their experience (i.e., state self-esteem, positive and negative emotion, and perceived valence of the event) in response to each event. Later, participants were presented with their event descriptions and were asked to recall their experience ratings from memory. As hypothesized, higher global self-esteem predicted positive shifts in memory for experience, whereas lower global self-esteem predicted negative shifts in memory for experience. Patterns of bias were strongest for remembered state self-esteem, moderate for positive emotion, and minimal for event valence. Self-esteem did not predict bias for negative emotion. Mood at the time of recall (measured in Study 2) generally did not account for the patterns. These findings strengthen the view that self-esteem is a rich source of knowledge about the self that can influence memory for some kinds of autobiographical experience. Copyright 2003 Society for Personality and Social Psychology, Inc.
The association between different night shiftwork factors and breast cancer: a case–control study
Fritschi, L; Erren, T C; Glass, D C; Girschik, J; Thomson, A K; Saunders, C; Boyle, T; El-Zaemey, S; Rogers, P; Peters, S; Slevin, T; D'Orsogna, A; de Vocht, F; Vermeulen, R; Heyworth, J S
2013-01-01
Background: Research on the possible association between shiftwork and breast cancer is complicated because there are many different shiftwork factors, which might be involved including: light at night, phase shift, sleep disruption and changes in lifestyle factors while on shiftwork (diet, physical activity, alcohol intake and low sun exposure). Methods: We conducted a population-based case–control study in Western Australia from 2009 to 2011 with 1205 incident breast cancer cases and 1789 frequency age-matched controls. A self-administered questionnaire was used to collect demographic, reproductive, and lifestyle factors and lifetime occupational history and a telephone interview was used to obtain further details about the shiftwork factors listed above. Results: A small increase in risk was suggested for those ever doing the graveyard shift (work between midnight and 0500 hours) and breast cancer (odds ratio (OR)=1.16, 95% confidence interval (CI)=0.97–1.39). For phase shift, we found a 22% increase in breast cancer risk (OR=1.22, 95% CI=1.01–1.47) with a statistically significant dose–response relationship (P=0.04). For the other shiftwork factors, risks were marginally elevated and not statistically significant. Conclusion: We found some evidence that some of the factors involved in shiftwork may be associated with breast cancer but the ORs were low and there were inconsistencies in duration and dose–response relationships. PMID:24022188
Fast Eigensolver for Computing 3D Earth's Normal Modes
NASA Astrophysics Data System (ADS)
Shi, J.; De Hoop, M. V.; Li, R.; Xi, Y.; Saad, Y.
2017-12-01
We present a novel parallel computational approach to compute Earth's normal modes. We discretize Earth via an unstructured tetrahedral mesh and apply the continuous Galerkin finite element method to the elasto-gravitational system. To resolve the eigenvalue pollution issue, following the analysis separating the seismic point spectrum, we utilize explicitly a representation of the displacement for describing the oscillations of the non-seismic modes in the fluid outer core. Effectively, we separate out the essential spectrum which is naturally related to the Brunt-Väisälä frequency. We introduce two Lanczos approaches with polynomial and rational filtering for solving this generalized eigenvalue problem in prescribed intervals. The polynomial filtering technique only accesses the matrix pair through matrix-vector products and is an ideal candidate for solving three-dimensional large-scale eigenvalue problems. The matrix-free scheme allows us to deal with fluid separation and self-gravitation in an efficient way, while the standard shift-and-invert method typically needs an explicit shifted matrix and its factorization. The rational filtering method converges much faster than the standard shift-and-invert procedure when computing all the eigenvalues inside an interval. Both two Lanczos approaches solve for the internal eigenvalues extremely accurately, comparing with the standard eigensolver. In our computational experiments, we compare our results with the radial earth model benchmark, and visualize the normal modes using vector plots to illustrate the properties of the displacements in different modes.
Tunable scattering cancellation cloak with plasmonic ellipsoids in the visible
NASA Astrophysics Data System (ADS)
Fruhnert, Martin; Monti, Alessio; Fernandez-Corbaton, Ivan; Alù, Andrea; Toscano, Alessandro; Bilotti, Filiberto; Rockstuhl, Carsten
2016-06-01
The scattering cancellation technique is a powerful tool to reduce the scattered field from electrically small objects in a specific frequency window. The technique relies on covering the object of interest with a shell that scatters light into a far field of equal strength as the object but with a phase shift of π . The resulting destructive interference prohibits its detection in measurements that probe the scattered light. Whereas at radio or microwave frequencies feasible designs have been proposed that allow us to tune the operational frequency upon request, similar capabilities have not yet been explored in the visible. However, such an ability is necessary to capitalize on the technique in many envisioned applications. Here, we solve the problem and study the use of small metallic nanoparticles with an ellipsoidal shape as the material from which the shell is made to build an isotropic geometry. Changing the aspect ratio of the ellipsoids allows us to change the operational frequency. The basic functionality is explored with two complementary analytical approaches. Additionally, we present a powerful multiscattering algorithm that can be used to perform full-wave simulations of clusters of arbitrary particles. We utilize this method to analyze the scattering of the presented designs numerically. Herein we provide useful guidelines for the fabrication of this cloak with self-assembly methods by investigating the effects of disorder.
Development of Michelson interferometer based spatial phase-shift digital shearography
NASA Astrophysics Data System (ADS)
Xie, Xin
Digital shearography is a non-contact, full field, optical measurement method, which has the capability of directly measuring the gradient of deformation. For high measurement sensitivity, phase evaluation method has to be introduced into digital shearography by phase-shift technique. Catalog by phase-shift method, digital phase-shift shearography can be divided into Temporal Phase-Shift Digital Shearography (TPS-DS) and Spatial Phase-Shift Digital Shearography (SPS-DS). TPS-DS is the most widely used phase-shift shearography system, due to its simple algorithm, easy operation and good phase-map quality. However, the application of TPS-DS is only limited in static/step-by-step loading measurement situation, due to its multi-step shifting process. In order to measure the strain under dynamic/continuous loading situation, a SPS-DS system has to be developed. This dissertation aims to develop a series of Michelson Interferometer based SPS-DS measurement methods to achieve the strain measurement by using only a single pair of speckle pattern images. The Michelson Interferometer based SPS-DS systems utilize special designed optical setup to introduce extra carrier frequency into the laser wavefront. The phase information corresponds to the strain field can be separated on the Fourier domain using a Fourier Transform and can further be evaluated with a Windowed Inverse Fourier Transform. With different optical setups and carrier frequency arrangements, the Michelson Interferometer based SPS-DS method is capable to achieve a variety of measurement tasks using only single pair of speckle pattern images. Catalog by the aimed measurand, these capable measurement tasks can be divided into five categories: 1) measurement of out-of-plane strain field with small shearing amount; 2) measurement of relative out-of-plane deformation field with big shearing amount; 3) simultaneous measurement of relative out-of-plane deformation field and deformation gradient field by using multiple carrier frequencies; 4) simultaneous measurement of two directional strain field using dual measurement channels 5) measurement of pure in-plane strain and pure out-of-plane strain with multiple carrier frequencies. The basic theory, optical path analysis, preliminary studies, results analysis and research plan are shown in detail in this dissertation.
Gómez-García, Teresa; Ruzafa-Martínez, María; Fuentelsaz-Gallego, Carmen; Madrid, Juan Antonio; Rol, Maria Angeles; Martínez-Madrid, María José; Moreno-Casbas, Teresa
2016-08-05
The main objective of this study was to determine the relationship between the characteristics of nurses' work environments in hospitals in the Spanish National Health System (SNHS) with nurse reported quality of care, and how care was provided by using different shifts schemes. The study also examined the relationship between job satisfaction, burnout, sleep quality and daytime drowsiness of nurses and shift work. This was a multicentre, observational, descriptive, cross-sectional study, centred on a self-administered questionnaire. The study was conducted in seven SNHS hospitals of different sizes. We recruited 635 registered nurses who worked on day, night and rotational shifts on surgical, medical and critical care units. Their average age was 41.1 years, their average work experience was 16.4 years and 90% worked full time. A descriptive and bivariate analysis was carried out to study the relationship between work environment, quality and safety care, and sleep quality of nurses working different shift patterns. 65.4% (410) of nurses worked on a rotating shift. The Practice Environment Scale of the Nursing Work Index classification ranked 20% (95) as favourable, showing differences in nurse manager ability, leadership and support between shifts (p=0.003). 46.6% (286) were sure that patients could manage their self-care after discharge, but there were differences between shifts (p=0.035). 33.1% (201) agreed with information being lost in the shift change, showing differences between shifts (p=0.002). The Pittsburgh Sleep Quality Index reflected an average of 6.8 (SD 3.39), with differences between shifts (p=0.017). Nursing requires shift work, and the results showed that the rotating shift was the most common. Rotating shift nurses reported worse perception in organisational and work environmental factors. Rotating and night shift nurses were less confident about patients' competence of self-care after discharge. The most common nursing care omissions reported were related to nursing care plans. For the Global Sleep Quality score, difference were found between day and night shift workers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Acoustic levitation and the Boltzmann-Ehrenfest principle
NASA Technical Reports Server (NTRS)
Putterman, S.; Rudnick, Joseph; Barmatz, M.
1989-01-01
The Boltzmann-Ehrenfest principle of adiabatic invariance relates the acoustic potential acting on a sample positioned in a single-mode cavity to the shift in resonant frequency caused by the presence of this sample. This general and simple relation applies to samples and cavities of arbitrary shape, dimension, and compressibility. Positioning forces and torques can, therefore, be determined from straightforward measurements of frequency shifts. Applications to the Rayleigh disk phenomenon and levitated cylinders are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Zhanlong; College of Physics, Jilin University, Changchun 130012; Shan Xiaoning
2012-07-09
The current paper investigates stimulated Raman scattering (SRS) when laser-induced plasma is formed in heavy water by focusing an intense pulsed 532 nm Nd:YAG laser beam at room temperature. An unexpected low-frequency SRS line attributed to the lattice translational modes of ice-VII (D{sub 2}O) is observed. The pressure of the plasma shockwave is estimated using low-frequency SRS line shift.
Simulation of Dual-Electrode Capacitively Coupled Plasma Discharges
NASA Astrophysics Data System (ADS)
Lu, Yijia; Ji, Linhong; Cheng, Jia
2016-12-01
Dual-electrode capacitively coupled plasma discharges are investigated here to lower the non-uniformity of plasma density. The dual-electrode structure proposed by Jung splits the electrode region and increases the flexibility of fine tuning non-uniformity. Different RF voltages, frequencies, phase-shifts and electrode areas are simulated and the influences are discussed. RF voltage and electrode area have a non-monotonic effect on non-uniformity, while frequency has a monotonic effect. Phase-shift has a cyclical influence on non-uniformity. A special combination of 224 V voltage and 11% area ratio with 10 MHz lowers the non-uniformity of the original set (200 V voltage and 0% area ratio with 10 MHz) by 46.5%. The position of the plasma density peak at the probe line has been tracked and properly tuning the phase-shift can obtain the same trace as tuning frequency or voltage. supported by National Natural Science Foundation of China (No. 51405261)
Nuclear spin noise in NMR revisited
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferrand, Guillaume; Luong, Michel; Huber, Gaspard
2015-09-07
The theoretical shapes of nuclear spin-noise spectra in NMR are derived by considering a receiver circuit with finite preamplifier input impedance and a transmission line between the preamplifier and the probe. Using this model, it becomes possible to reproduce all observed experimental features: variation of the NMR resonance linewidth as a function of the transmission line phase, nuclear spin-noise signals appearing as a “bump” or as a “dip” superimposed on the average electronic noise level even for a spin system and probe at the same temperature, pure in-phase Lorentzian spin-noise signals exhibiting non-vanishing frequency shifts. Extensive comparisons to experimental measurementsmore » validate the model predictions, and define the conditions for obtaining pure in-phase Lorentzian-shape nuclear spin noise with a vanishing frequency shift, in other words, the conditions for simultaneously obtaining the spin-noise and frequency-shift tuning optima.« less
Microcantilever-based gas sensor employing two simultaneous physical sensing modes
Loui, Albert; Sirbuly, Donald J; Elhadj, Selim; McCall, Scott K; Hart, Bradley R; Ratto, Timothy V
2014-06-24
According to one embodiment, a system for detecting and identifying gases includes a piezoresistive microcantilever transducer, wherein dissipation of heat from the piezoresistive microcantilever into one or more gases is measured by changes in an electrical resistance of the piezoresistor, a vibrating microcantilever transducer, wherein shifts are measured in resonant frequency of the vibrating microcantilever due to viscous damping thereof by the one or more gases, and a subsystem for correlating the measured resistance changes and the resonant frequency shifts to the one or more gases. In another embodiment, a method for detecting and identifying one or more gases includes determining dissipation of heat from a microcantilever into one or more gases, and determining shifts in resonant frequency of the microcantilever due to viscous damping thereof by the one or more gases. Other systems, methods, and computer program products are also described according to more embodiments.
Improved frequency/voltage converters for fast quartz crystal microbalance applications.
Torres, R; García, J V; Arnau, A; Perrot, H; Kim, L To Thi; Gabrielli, C
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1 kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10 mVHz, for a frequency shift resolution of 0.1 Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5 to 10 MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Improved frequency/voltage converters for fast quartz crystal microbalance applications
NASA Astrophysics Data System (ADS)
Torres, R.; García, J. V.; Arnau, A.; Perrot, H.; Kim, L. To Thi; Gabrielli, C.
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10mV/Hz, for a frequency shift resolution of 0.1Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5to10MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Neural representation of the self-heard biosonar click in bottlenose dolphins (Tursiops truncatus).
Finneran, James J; Mulsow, Jason; Houser, Dorian S; Schlundt, Carolyn E
2017-05-01
The neural representation of the dolphin broadband biosonar click was investigated by measuring auditory brainstem responses (ABRs) to "self-heard" clicks masked with noise bursts having various high-pass cutoff frequencies. Narrowband ABRs were obtained by sequentially subtracting responses obtained with noise having lower high-pass cutoff frequencies from those obtained with noise having higher cutoff frequencies. For comparison to the biosonar data, ABRs were also measured in a passive listening experiment, where external clicks and masking noise were presented to the dolphins and narrowband ABRs were again derived using the subtractive high-pass noise technique. The results showed little change in the peak latencies of the ABR to the self-heard click from 28 to 113 kHz; i.e., the high-frequency neural responses to the self-heard click were delayed relative to those of an external, spectrally "pink" click. The neural representation of the self-heard click is thus highly synchronous across the echolocation frequencies and does not strongly resemble that of a frequency modulated downsweep (i.e., decreasing-frequency chirp). Longer ABR latencies at higher frequencies are hypothesized to arise from spectral differences between self-heard clicks and external clicks, forward masking from previously emitted biosonar clicks, or neural inhibition accompanying the emission of clicks.
Neural representation of the self-heard biosonar click in bottlenose dolphins (Tursiops truncatus)
Finneran, James J.; Mulsow, Jason; Houser, Dorian S.; Schlundt, Carolyn E.
2017-01-01
The neural representation of the dolphin broadband biosonar click was investigated by measuring auditory brainstem responses (ABRs) to “self-heard” clicks masked with noise bursts having various high-pass cutoff frequencies. Narrowband ABRs were obtained by sequentially subtracting responses obtained with noise having lower high-pass cutoff frequencies from those obtained with noise having higher cutoff frequencies. For comparison to the biosonar data, ABRs were also measured in a passive listening experiment, where external clicks and masking noise were presented to the dolphins and narrowband ABRs were again derived using the subtractive high-pass noise technique. The results showed little change in the peak latencies of the ABR to the self-heard click from 28 to 113 kHz; i.e., the high-frequency neural responses to the self-heard click were delayed relative to those of an external, spectrally “pink” click. The neural representation of the self-heard click is thus highly synchronous across the echolocation frequencies and does not strongly resemble that of a frequency modulated downsweep (i.e., decreasing-frequency chirp). Longer ABR latencies at higher frequencies are hypothesized to arise from spectral differences between self-heard clicks and external clicks, forward masking from previously emitted biosonar clicks, or neural inhibition accompanying the emission of clicks. PMID:28599518