Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan
2017-09-01
Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%), compared to the sensitivity (91-100%) of the new molecular diagnostic workflow. Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.
Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David
2017-01-01
Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65–88%), compared to the sensitivity (91–100%) of the new molecular diagnostic workflow. Conclusions/Significance Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited. PMID:28915255
Instrumentation in molecular imaging.
Wells, R Glenn
2016-12-01
In vivo molecular imaging is a challenging task and no single type of imaging system provides an ideal solution. Nuclear medicine techniques like SPECT and PET provide excellent sensitivity but have poor spatial resolution. Optical imaging has excellent sensitivity and spatial resolution, but light photons interact strongly with tissues and so only small animals and targets near the surface can be accurately visualized. CT and MRI have exquisite spatial resolution, but greatly reduced sensitivity. To overcome the limitations of individual modalities, molecular imaging systems often combine individual cameras together, for example, merging nuclear medicine cameras with CT or MRI to allow the visualization of molecular processes with both high sensitivity and high spatial resolution.
Molecular breast imaging using a dedicated high-performance instrument
NASA Astrophysics Data System (ADS)
O'Connor, Michael K.; Wagenaar, Douglas; Hruska, Carrie B.; Phillips, Stephen; Caravaglia, Gina; Rhodes, Deborah
2006-08-01
In women with radiographically dense breasts, the sensitivity of mammography is less than 50%. With the increase in the percent of women with dense breasts, it is important to look at alternative screening techniques for this population. This article reviews the strengths and weaknesses of current imaging techniques and focuses on recent developments in semiconductor-based gamma camera systems that offer significant improvements in image quality over that achievable with single-crystal sodium iodide systems. We have developed a technique known as Molecular Breast Imaging (MBI) using small field of view Cadmium Zinc Telluride (CZT) gamma cameras that permits the breast to be imaged in a similar manner to mammography, using light pain-free compression. Computer simulations and experimental studies have shown that use of low-energy high sensitivity collimation coupled with the excellent energy resolution and intrinsic spatial resolution of CZT detectors provides optimum image quality for the detection of small breast lesions. Preliminary clinical studies with a prototype dual-detector system have demonstrated that Molecular Breast Imaging has a sensitivity of ~90% for the detection of breast tumors less than 10 mm in diameter. By comparison, conventional scintimammography only achieves a sensitivity of 50% in the detection of lesions < 10 mm. Because Molecular Breast Imaging is not affected by breast density, this technique may offer an important adjunct to mammography in the evaluation of women with dense breast parenchyma.
New Researches and Application Progress of Commonly Used Optical Molecular Imaging Technology
Chen, Zhi-Yi; Yang, Feng; Lin, Yan; Zhou, Qiu-Lan; Liao, Yang-Ying
2014-01-01
Optical molecular imaging, a new medical imaging technique, is developed based on genomics, proteomics and modern optical imaging technique, characterized by non-invasiveness, non-radiativity, high cost-effectiveness, high resolution, high sensitivity and simple operation in comparison with conventional imaging modalities. Currently, it has become one of the most widely used molecular imaging techniques and has been applied in gene expression regulation and activity detection, biological development and cytological detection, drug research and development, pathogenesis research, pharmaceutical effect evaluation and therapeutic effect evaluation, and so forth, This paper will review the latest researches and application progresses of commonly used optical molecular imaging techniques such as bioluminescence imaging and fluorescence molecular imaging. PMID:24696850
Kojima, Taisuke
2018-01-01
Molecular adsorption on a sensing surface involves molecule-substrate and molecule-molecule interactions. Combining optical systems and a quartz crystal microbalance (QCM) on the same sensing surface allows the quantification of such interactions and reveals the physicochemical properties of the adsorbed molecules. However, low sensitivity of the current reflection-based techniques compared to the QCM technique hinders the quantitative analysis of the adsorption events. Here, a layer-by-layer surface modification of a QCM sensor is studied to increase the optical sensitivity. The intermediate layers of organic-inorganic molecules and metal-metal oxide were explored on a gold (Au) surface of a QCM sensor. First, polyhedral oligomeric silsesquioxane-derivatives that served as the organic-inorganic intermediate layer were synthesized and modified on the Au-QCM surface. Meanwhile, titanium oxide, fabricated by anodic oxidation of titanium, was used as a metal-metal oxide intermediate layer on a titanium-coated QCM surface. The developed technique enabled interrogation of the molecular adsorption owing to the enhanced optical sensitivity.
Yu, Gloria Qingyu; Yu, Peiqiang
2015-09-01
The objectives of this project were to (1) combine vibrational spectroscopy with chemometric multivariate techniques to determine the effect of processing applications on molecular structural changes of lipid biopolymer that mainly related to functional groups in green- and yellow-type Crop Development Centre (CDC) pea varieties [CDC strike (green-type) vs. CDC meadow (yellow-type)] that occurred during various processing applications; (2) relatively quantify the effect of processing applications on the antisymmetric CH3 ("CH3as") and CH2 ("CH2as") (ca. 2960 and 2923 cm(-1), respectively), symmetric CH3 ("CH3s") and CH2 ("CH2s") (ca. 2873 and 2954 cm(-1), respectively) functional groups and carbonyl C=O ester (ca. 1745 cm(-1)) spectral intensities as well as their ratios of antisymmetric CH3 to antisymmetric CH2 (ratio of CH3as to CH2as), ratios of symmetric CH3 to symmetric CH2 (ratio of CH3s to CH2s), and ratios of carbonyl C=O ester peak area to total CH peak area (ratio of C=O ester to CH); and (3) illustrate non-invasive techniques to detect the sensitivity of individual molecular functional group to the various processing applications in the recently developed different types of pea varieties. The hypothesis of this research was that processing applications modified the molecular structure profiles in the processed products as opposed to original unprocessed pea seeds. The results showed that the different processing methods had different impacts on lipid molecular functional groups. Different lipid functional groups had different sensitivity to various heat processing applications. These changes were detected by advanced molecular spectroscopy with chemometric techniques which may be highly related to lipid utilization and availability. The multivariate molecular spectral analyses, cluster analysis, and principal component analysis of original spectra (without spectral parameterization) are unable to fully distinguish the structural differences in the antisymmetric and symmetric CH3 and CH2 spectral region (ca. 3001-2799 cm(-1)) and carbonyl C=O ester band region (ca. 1771-1714 cm(-1)). This result indicated that the sensitivity to detect treatment difference by multivariate analysis of cluster analysis (CLA) and principal components analysis (PCA) might be lower compared with univariate molecular spectral analysis. In the future, other more sensitive techniques such as "discriminant analysis" could be considered for discriminating and classifying structural differences. Molecular spectroscopy can be used as non-invasive technique to study processing-induced structural changes that are related to lipid compound in legume seeds.
Molecular methods for pathogen detection and quantification
USDA-ARS?s Scientific Manuscript database
Ongoing interest in convenient, inexpensive, fast, sensitive and accurate techniques for detecting and/or quantifying the presence of soybean pathogens has resulted in increased usage of molecular tools. The method of extracting a molecular target (usually DNA or RNA) for detection depends wholly up...
Bojunga, Jörg; Kusterer, Klaus; Schumm-Draeger, Petra-Maria; Usadel, Klaus-Henning
2002-12-01
Thyroid cancers are the most common endocrine malignancies and are being diagnosed with increasing frequency. In addition to other measures, diagnosis is based on fine-needle aspiration cytology examination. Recently, new assays using reverse transcription-polymerase chain reaction (PCR) are being tested to improve sensitivity and specificity of primary diagnosis and detection of recurrent thyroid cancer. In the preoperative diagnosis of thyroid cancer, several tissue- and/or tumor-specific mRNA have been described and in several cases, a higher sensitivity and specificity could be achieved using molecular techniques compared to conventional methods. In the postoperative follow-up of patients with thyroid cancer, conflicting data have been published and the use of PCR techniques revealed several problems of the molecular approach, which are based on some technical as well as biologic limitations. Despite these problems, which are discussed in detail in this review, molecular techniques may nevertheless improve the sensitivity and accuracy of fine-needle aspiration of thyroid nodules, fine-needle aspiration of metastases, and detection of recurrent disease in peripheral blood samples.
Surface Plasmon Resonance-Based Fiber Optic Sensors Utilizing Molecular Imprinting
Gupta, Banshi D.; Shrivastav, Anand M.; Usha, Sruthi P.
2016-01-01
Molecular imprinting is earning worldwide attention from researchers in the field of sensing and diagnostic applications, due to its properties of inevitable specific affinity for the template molecule. The fabrication of complementary template imprints allows this technique to achieve high selectivity for the analyte to be sensed. Sensors incorporating this technique along with surface plasmon or localized surface plasmon resonance (SPR/LSPR) provide highly sensitive real time detection with quick response times. Unfolding these techniques with optical fiber provide the additional advantages of miniaturized probes with ease of handling, online monitoring and remote sensing. In this review a summary of optical fiber sensors using the combined approaches of molecularly imprinted polymer (MIP) and the SPR/LSPR technique is discussed. An overview of the fundamentals of SPR/LSPR implementation on optical fiber is provided. The review also covers the molecular imprinting technology (MIT) with its elementary study, synthesis procedures and its applications for chemical and biological anlayte detection with different sensing methods. In conclusion, we explore the advantages, challenges and the future perspectives of developing highly sensitive and selective methods for the detection of analytes utilizing MIT with the SPR/LSPR phenomenon on optical fiber platforms. PMID:27589746
Zehender, Hartmut; Mayr, Lorenz M
2007-10-01
In recent years, mass spectrometry has gained widespread use as an assay and screening technology in drug discovery because it enables sensitive, label-free detection of low-molecular weight modulators of biomolecules as well as sensitive and accurate detection of high-molecular weight modifications of biomolecules. Electrospray and matrix-assisted laser desorption ionization are the most widely used ionization techniques to identify chemical compounds interfering with enzymatic function, receptor-ligand binding or molecules modulating a protein-protein interaction of interest. Mass spectrometry based techniques are no longer restricted to screening in biochemical assay systems but have now become also applicable to imaging of biomolecules and chemical compounds in cell-based assay systems and even in highly complex tissue sections.
Metamaterial absorber for molecular detection and identification (Conference Presentation)
NASA Astrophysics Data System (ADS)
Tanaka, Takuo
2017-03-01
Metamaterial absorber was used for a background-suppressed surface-enhanced molecular detection technique. By utilizing the resonant coupling between plasmonic modes of a metamaterial absorber and infrared (IR) vibrational modes of a self-assembled monolayer (SAM), attomole level molecular sensitivity was experimentally demonstrated. IR absorption spectroscopy of molecular vibrations is of importance in chemical, material, medical science and so on, since it provides essential information of the molecular structure, composition, and orientation. In the vibrational spectroscopic techniques, in addition to the weak signals from the molecules, strong background degrades the signal-to-noise ratio, and suppression of the background is crucial for the further improvement of the sensitivity. Here, we demonstrate low-background resonant Surface enhanced IR absorption (SEIRA) by using the metamaterial IR absorber that offers significant background suppression as well as plasmonic enhancement. By using mask-less laser lithography technique, metamaterial absorber which consisted of 1D array of Au micro-ribbons on a thick Au film separated by a transparent gap layer made of MgF2 was fabricated. This metamaterial structure was designed to exhibit an anomalous IR absorption at 3000 cm-1, which spectrally overlapped with C-H stretching vibrational modes. 16-Mercaptohexadecanoic acid (16-MHDA) was used as a test molecule, which formed a 2-nm thick SAM with their thiol head-group chemisorbed on the Au surface. In the FTIR measurements, the symmetric and asymmetric C-H stretching modes were clearly observed as reflection peaks within a broad plasmonic absorption of the metamaterial, and 1.8 attomole molecular sensitivity was experimentally demonstrated.
INTERNALIZATION AND FATE OF INDIVIDUAL MANUFACTURED NANOMATERIAL WITHIN LIVING CELLS
Using quantitative fluorescence imaging with single molecule sensitivity, combined with molecular biology techniques, we have been investigating the cellular interactions and fate of one nanoparticle or nanoscale aggregate at a time, identifying molecular interactions and cellula...
Fecal Molecular Markers for Colorectal Cancer Screening
Kanthan, Rani; Senger, Jenna-Lynn; Kanthan, Selliah Chandra
2012-01-01
Despite multiple screening techniques, including colonoscopy, flexible sigmoidoscopy, radiological imaging, and fecal occult blood testing, colorectal cancer remains a leading cause of death. As these techniques improve, their sensitivity to detect malignant lesions is increasing; however, detection of precursor lesions remains problematic and has generated a lack of general acceptance for their widespread usage. Early detection by an accurate, noninvasive, cost-effective, simple-to-use screening technique is central to decreasing the incidence and mortality of this disease. Recent advances in the development of molecular markers in faecal specimens are encouraging for its use as a screening tool. Genetic mutations and epigenetic alterations that result from the carcinogenetic process can be detected by coprocytobiology in the colonocytes exfoliated from the lesion into the fecal matter. These markers have shown promising sensitivity and specificity in the detection of both malignant and premalignant lesions and are gaining popularity as a noninvasive technique that is representative of the entire colon. In this paper, we summarize the genetic and epigenetic fecal molecular markers that have been identified as potential targets in the screening of colorectal cancer. PMID:22969796
Micro-machined calorimetric biosensors
Doktycz, Mitchel J.; Britton, Jr., Charles L.; Smith, Stephen F.; Oden, Patrick I.; Bryan, William L.; Moore, James A.; Thundat, Thomas G.; Warmack, Robert J.
2002-01-01
A method and apparatus are provided for detecting and monitoring micro-volumetric enthalpic changes caused by molecular reactions. Micro-machining techniques are used to create very small thermally isolated masses incorporating temperature-sensitive circuitry. The thermally isolated masses are provided with a molecular layer or coating, and the temperature-sensitive circuitry provides an indication when the molecules of the coating are involved in an enthalpic reaction. The thermally isolated masses may be provided singly or in arrays and, in the latter case, the molecular coatings may differ to provide qualitative and/or quantitative assays of a substance.
Molecular Diagnostic Testing for Aspergillus
Powers-Fletcher, Margaret V.
2016-01-01
The direct detection of Aspergillus nucleic acid in clinical specimens has the potential to improve the diagnosis of aspergillosis by offering more rapid and sensitive identification of invasive infections than is possible with traditional techniques, such as culture or histopathology. Molecular tests for Aspergillus have been limited historically by lack of standardization and variable sensitivities and specificities. Recent efforts have been directed at addressing these limitations and optimizing assay performance using a variety of specimen types. This review provides a summary of standardization efforts and outlines the complexities of molecular testing for Aspergillus in clinical mycology. PMID:27487954
Imaging-based molecular barcoding with pixelated dielectric metasurfaces
NASA Astrophysics Data System (ADS)
Tittl, Andreas; Leitis, Aleksandrs; Liu, Mingkai; Yesilkoy, Filiz; Choi, Duk-Yong; Neshev, Dragomir N.; Kivshar, Yuri S.; Altug, Hatice
2018-06-01
Metasurfaces provide opportunities for wavefront control, flat optics, and subwavelength light focusing. We developed an imaging-based nanophotonic method for detecting mid-infrared molecular fingerprints and implemented it for the chemical identification and compositional analysis of surface-bound analytes. Our technique features a two-dimensional pixelated dielectric metasurface with a range of ultrasharp resonances, each tuned to a discrete frequency; this enables molecular absorption signatures to be read out at multiple spectral points, and the resulting information is then translated into a barcode-like spatial absorption map for imaging. The signatures of biological, polymer, and pesticide molecules can be detected with high sensitivity, covering applications such as biosensing and environmental monitoring. Our chemically specific technique can resolve absorption fingerprints without the need for spectrometry, frequency scanning, or moving mechanical parts, thereby paving the way toward sensitive and versatile miniaturized mid-infrared spectroscopy devices.
Coherent nonlinear optical imaging: beyond fluorescence microscopy.
Min, Wei; Freudiger, Christian W; Lu, Sijia; Xie, X Sunney
2011-01-01
The quest for ultrahigh detection sensitivity with spectroscopic contrasts other than fluorescence has led to various novel approaches to optical microscopy of biological systems. Coherent nonlinear optical imaging, especially the recently developed nonlinear dissipation microscopy (including stimulated Raman scattering and two-photon absorption) and pump-probe microscopy (including excited-state absorption, stimulated emission, and ground-state depletion), provides new image contrasts for nonfluorescent species. Thanks to the high-frequency modulation transfer scheme, these imaging techniques exhibit superb detection sensitivity. By directly interrogating vibrational and/or electronic energy levels of molecules, they offer high molecular specificity. Here we review the underlying principles and excitation and detection schemes, as well as exemplary biomedical applications of this emerging class of molecular imaging techniques.
Molecular Diode Studies Based on a Highly Sensitive Molecular Measurement Technique.
Iwane, Madoka; Fujii, Shintaro; Kiguchi, Manabu
2017-04-26
In 1974, molecular electronics pioneers Mark Ratner and Arieh Aviram predicted that a single molecule could act as a diode, in which electronic current can be rectified. The electronic rectification property of the diode is one of basic functions of electronic components and since then, the molecular diode has been investigated as a first single-molecule device that would have a practical application. In this review, we first describe the experimental fabrication and electronic characterization techniques of molecular diodes consisting of a small number of molecules or a single molecule. Then, two main mechanisms of the rectification property of the molecular diode are discussed. Finally, representative results for the molecular diode are reviewed and a brief outlook on crucial issues that need to be addressed in future research is discussed.
Molecular Diode Studies Based on a Highly Sensitive Molecular Measurement Technique
Iwane, Madoka; Fujii, Shintaro; Kiguchi, Manabu
2017-01-01
In 1974, molecular electronics pioneers Mark Ratner and Arieh Aviram predicted that a single molecule could act as a diode, in which electronic current can be rectified. The electronic rectification property of the diode is one of basic functions of electronic components and since then, the molecular diode has been investigated as a first single-molecule device that would have a practical application. In this review, we first describe the experimental fabrication and electronic characterization techniques of molecular diodes consisting of a small number of molecules or a single molecule. Then, two main mechanisms of the rectification property of the molecular diode are discussed. Finally, representative results for the molecular diode are reviewed and a brief outlook on crucial issues that need to be addressed in future research is discussed. PMID:28445393
Ultra-High Aggregate Bandwidth Two-Dimensional Multiple-Wavelength Diode Laser Arrays
1993-12-09
during the growth of the cavity spacer region using the fact that the molecular beam epitaxy growth of GaAs is highly sensitive to the substrate... molecular beam epitaxy (MBE) crystal growth, the GaAs growth rate is highly sensitive to the substrate temperature above 650"C (2], a GaAs/AIGaAs... epitaxial growth technique to make reproducible and repeatable multi-wavelength VCSEL arrays. Our approach to fabricate the spatially graded layer
Song, Heli; Liu, Qingyun; Xie, Yongshu
2018-02-15
As a promising low-cost solar energy conversion technique, dye-sensitized solar cells have undergone spectacular development since 1991. For practical applications, improvement of power conversion efficiency has always been one of the major research topics. Porphyrins are outstanding sensitizers endowed with strong sunlight harvesting ability in the visible region and multiple reaction sites available for functionalization. However, judicious molecular design in consideration of light-harvest, energy levels, operational dynamics, adsorption geometry and suppression of back reactions is specifically required for achieving excellent photovoltaic performance. This feature article highlights some of the recently developed porphyrin sensitizers, especially focusing on the systematic dye structure optimization approach in combination with coadsorption and cosensitization methods in pursuing higher efficiencies. Herein, we expect to provide more insights into the structure-performance correlation and molecular engineering strategies in a stepwise manner.
Immunohistochemistry as a surrogate for molecular testing: a review.
Swanson, Paul E
2015-02-01
Despite the myriad of genetic and epigenetic alterations in human neoplasms that seem to demand specific molecular probes for their identification and practical application to diagnostic pathology, immunohistochemistry (IHC) remains a vital component of laboratory testing in the emerging molecular era. The development and proper application of sensitive and specific antibodies raised against cryptic proteins only expressed in quantity after gene translocation, translocation-specific chimeric fusion peptides, and gene products overexpressed because of gene amplification demonstrate that IHC is a legitimate surrogate for traditional cytogenetic and in situ hybridization-based identification of chromosomal abnormalities, if not a viable molecular technique in its own right. Similarly, the detection of mutational events, through the reliable demonstration of protein loss, the identification of proteins overexpressed because of activating mutations, the specific visualization of mutant gene products, and the localization of splice variant gene products emphasizes the potential value of IHC as a surrogate for mutational analyses of genes important to both diagnosis and prediction of therapeutic response. In the latter setting IHC also provides a means of approximating gene expression profiles in the molecular classification and risk stratification of human neoplasms. For time being, the application of appropriately targeted sensitive and specific antibodies provides a cost-effective screening modality, if not replacement, for selected molecular techniques, but IHC will lose its value if the development of companion tests for emerging novel biomarkers does not keep pace with molecular techniques, particularly as the costs and time constraints of genomic sequencing diminish over time.
Nucleic Acid-Based Approaches for Detection of Viral Hepatitis
Behzadi, Payam; Ranjbar, Reza; Alavian, Seyed Moayed
2014-01-01
Context: To determining suitable nucleic acid diagnostics for individual viral hepatitis agent, an extensive search using related keywords was done in major medical library and data were collected, categorized, and summarized in different sections. Results: Various types of molecular biology tools can be used to detect and quantify viral genomic elements and analyze the sequences. These molecular assays are proper technologies for rapidly detecting viral agents with high accuracy, high sensitivity, and high specificity. Nonetheless, the application of each diagnostic method is completely dependent on viral agent. Conclusions: Despite rapidity, automation, accuracy, cost-effectiveness, high sensitivity, and high specificity of molecular techniques, each type of molecular technology has its own advantages and disadvantages. PMID:25789132
Molecular oxygen detection using frequency modulation diode laser spectroscopy
NASA Technical Reports Server (NTRS)
Wang, Liang-Guo; Sachse, Glen
1990-01-01
A high-sensitivity spectroscopic measurement of O2 using two-tone frequency modulation spectroscopy with a GaAlAs diode laser is presented. An oxygen sensor based on this technique would be non-intrusive, compact and possess high sensitivity and fast time response.
A Sensitive TLRH Targeted Imaging Technique for Ultrasonic Molecular Imaging
Hu, Xiaowen; Zheng, Hairong; Kruse, Dustin E.; Sutcliffe, Patrick; Stephens, Douglas N.; Ferrara, Katherine W.
2010-01-01
The primary goals of ultrasound molecular imaging are the detection and imaging of ultrasound contrast agents (microbubbles), which are bound to specific vascular surface receptors. Imaging methods that can sensitively and selectively detect and distinguish bound microbubbles from freely circulating microbubbles (free microbubbles) and surrounding tissue are critically important for the practical application of ultrasound contrast molecular imaging. Microbubbles excited by low frequency acoustic pulses emit wide-band echoes with a bandwidth extending beyond 20 MHz; we refer to this technique as TLRH (transmission at a low frequency and reception at a high frequency). Using this wideband, transient echo, we have developed and implemented a targeted imaging technique incorporating a multi-frequency co-linear array and the Siemens Antares® imaging system. The multi-frequency co-linear array integrates a center 5.4 MHz array, used to receive echoes and produce radiation force, and two outer 1.5 MHz arrays used to transmit low frequency incident pulses. The targeted imaging technique makes use of an acoustic radiation force sub-sequence to enhance accumulation and a TLRH imaging sub-sequence to detect bound microbubbles. The radiofrequency (RF) data obtained from the TLRH imaging sub-sequence are processsed to separate echo signatures between tissue, free microbubbles, and bound microbubbles. By imaging biotin-coated microbubbles targeted to avidin-coated cellulose tubes, we demonstrate that the proposed method has a high contrast-to-tissue ratio (up to 34 dB) and a high sensitivity to bound microbubbles (with the ratio of echoes from bound microbubbles versus free microbubbles extending up to 23 dB). The effects of the imaging pulse acoustic pressure, the radiation force sub-sequence and the use of various slow-time filters on the targeted imaging quality are studied. The TLRH targeted imaging method is demonstrated in this study to provide sensitive and selective detection of bound microbubbles for ultrasound molecularly-targeted imaging. PMID:20178897
Hammond, G. Denise; Vojta, Adam L.; Grant, Sheila A.; Hunt, Heather K.
2016-01-01
The creation of label-free biosensors capable of accurately detecting trace contaminants, particularly small organic molecules, is of significant interest for applications in environmental monitoring. This is achieved by pairing a high-sensitivity signal transducer with a biorecognition element that imparts selectivity towards the compound of interest. However, many environmental pollutants do not have corresponding biorecognition elements. Fortunately, biomimetic chemistries, such as molecular imprinting, allow for the design of artificial receptors with very high selectivity for the target. Here, we perform a proof-of-concept study to show how artificial receptors may be created from inorganic silanes using the molecular imprinting technique and paired with high-sensitivity transducers without loss of device performance. Silica microsphere Whispering Gallery Mode optical microresonators are coated with a silica thin film templated by a small fluorescent dye, fluorescein isothiocyanate, which serves as our model target. Oxygen plasma degradation and solvent extraction of the template are compared. Extracted optical devices are interacted with the template molecule to confirm successful sorption of the template. Surface characterization is accomplished via fluorescence and optical microscopy, ellipsometry, optical profilometry, and contact angle measurements. The quality factors of the devices are measured to evaluate the impact of the coating on device sensitivity. The resulting devices show uniform surface coating with no microstructural damage with Q factors above 106. This is the first report demonstrating the integration of these devices with molecular imprinting techniques, and could lead to new routes to biosensor creation for environmental monitoring. PMID:27314397
High sensitivity optical molecular imaging system
NASA Astrophysics Data System (ADS)
An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie
2018-02-01
Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.
Molecular engineering of sensitizers for dye-sensitized solar cell applications.
Giribabu, Lingamallu; Kanaparthi, Ravi Kumar; Velkannan, Veerapandian
2012-06-01
Dye-sensitized solar cells (DSSCs) have attracted considerable attention in recent years as they offer the possibility of low-cost conversion of photovoltaic energy. This account focuses on recent advances in molecular design and technological aspects of sensitizers based on metal complexes, metal-free organics and tetrapyrrolic compounds which include porphyrins, phthalocyanines as well as corroles. Special attention has been paid to the design principles of these dyes, and co-sensitization, an emerging technique to extend the absorption range, is also discussed as a way to improve the performance of the device. This account also focuses on recent advances of efficient ruthenium sensitizers as well as other metal complexes and their applications in DSSCs. Recent developments in the area of metal-free organic and tetrapyrrolic sensitizers are also discussed. Copyright © 2012 The Japan Chemical Journal Forum and Wiley Periodicals, Inc.
Ultrafast and nonlinear surface-enhanced Raman spectroscopy.
Gruenke, Natalie L; Cardinal, M Fernanda; McAnally, Michael O; Frontiera, Renee R; Schatz, George C; Van Duyne, Richard P
2016-04-21
Ultrafast surface-enhanced Raman spectroscopy (SERS) has the potential to study molecular dynamics near plasmonic surfaces to better understand plasmon-mediated chemical reactions such as plasmonically-enhanced photocatalytic or photovoltaic processes. This review discusses the combination of ultrafast Raman spectroscopic techniques with plasmonic substrates for high temporal resolution, high sensitivity, and high spatial resolution vibrational spectroscopy. First, we introduce background information relevant to ultrafast SERS: the mechanisms of surface enhancement in Raman scattering, the characterization of plasmonic materials with ultrafast techniques, and early complementary techniques to study molecule-plasmon interactions. We then discuss recent advances in surface-enhanced Raman spectroscopies with ultrafast pulses with a focus on the study of molecule-plasmon coupling and molecular dynamics with high sensitivity. We also highlight the challenges faced by this field by the potential damage caused by concentrated, highly energetic pulsed fields in plasmonic hotspots, and finally the potential for future ultrafast SERS studies.
Broad-Spectrum Molecular Detection of Fungal Nucleic Acids by PCR-Based Amplification Techniques.
Czurda, Stefan; Lion, Thomas
2017-01-01
Over the past decade, the incidence of life-threatening invasive fungal infections has dramatically increased. Infections caused by hitherto rare and emerging fungal pathogens are associated with significant morbidity and mortality among immunocompromised patients. These observations render the coverage of a broad range of clinically relevant fungal pathogens highly important. The so-called panfungal or, perhaps more correctly, broad-range nucleic acid amplification techniques do not only facilitate sensitive detection of all clinically relevant fungal species but are also rapid and can be applied to analyses of any patient specimens. They have therefore become valuable diagnostic tools for sensitive screening of patients at risk of invasive fungal infections. This chapter summarizes the currently available molecular technologies employed in testing of a wide range of fungal pathogens, and provides a detailed workflow for patient screening by broad-spectrum nucleic acid amplification techniques.
DNA-based techniques for authentication of processed food and food supplements.
Lo, Yat-Tung; Shaw, Pang-Chui
2018-02-01
Authentication of food or food supplements with medicinal values is important to avoid adverse toxic effects, provide consumer rights, as well as for certification purpose. Compared to morphological and spectrometric techniques, molecular authentication is found to be accurate, sensitive and reliable. However, DNA degradation and inclusion of inhibitors may lead to failure in PCR amplification. This paper reviews on the existing DNA extraction and PCR protocols, and the use of small size DNA markers with sufficient discriminative power for molecular authentication. Various emerging new molecular techniques such as isothermal amplification for on-site diagnosis, next-generation sequencing for high-throughput species identification, high resolution melting analysis for quick species differentiation, DNA array techniques for rapid detection and quantitative determination in food products are also discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Next Generation LOCAD-PTS Cartridge Development
NASA Technical Reports Server (NTRS)
Morris, H.; Nutter, D.; Weite, E.; Wells, M.; Maule, J.; Damon, M.; Monaco, L.; Steele, A.; Wainwright, N.
2008-01-01
Future astrobiology exploration missions will require rapid, point-of-use techniques for surface science experiments and contamination monitoring. The Lab-On-a-Chip Application Development (LOCAD) team is developing operational instruments that advance spaceflight technologies to molecular-based methods. Currently, LOCAD-Portable Test System (PTS) is quantifying levels of the bacterial molecule endotoxin onboard the Internatioal Space Station. Future research and development will focus on more sensitive molecular techniques that expand the number of compounds detected to include beta-glucan from fungal cell walls.
Streeter, Jason E.; Gessner, Ryan; Miles, Iman; Dayton, Paul A.
2010-01-01
Molecular imaging with ultrasound relies on microbubble contrast agents (MCAs) selectively adhering to a ligand-specific target. Prior studies have shown that only small quantities of microbubbles are retained at their target sites, therefore, enhancing contrast sensitivity to low concentrations of microbubbles is essential to improve molecular imaging techniques. In order to assess the effect of MCA diameter on imaging sensitivity, perfusion and molecular imaging studies were performed with microbubbles of varying size distributions. To assess signal improvement and MCA circulation time as a function of size and concentration, blood perfusion was imaged in rat kidneys using nontargeted size-sorted MCAs with a Siemens Sequoia ultrasound system (Siemans, Mountain View, CA) in cadence pulse sequencing (CPS) mode. Molecular imaging sensitivity improvements were studied with size-sorted αvβ3-targeted bubbles in both fibrosarcoma and R3230 rat tumor models. In perfusion imaging studies, video intensity and contrast persistence was ≈8 times and ≈3 times greater respectively, for “sorted 3-micron” MCAs (diameter, 3.3 ± 1.95 μm) when compared to “unsorted” MCAs (diameter, 0.9 ± 0.45 μm) at low concentrations. In targeted experiments, application of sorted 3-micron MCAs resulted in a ≈20 times video intensity increase over unsorted populations. Tailoring size-distributions results in substantial imaging sensitivity improvement over unsorted populations, which is essential in maximizing sensitivity to small numbers of MCAs for molecular imaging. PMID:20236606
La Belle, Jeffrey T; Fairchild, Aaron; Demirok, Ugur K; Verma, Aman
2013-05-15
There is a critical need for more accurate, highly sensitive and specific assay for disease diagnosis and management. A novel, multiplexed, single sensor using rapid and label free electrochemical impedance spectroscopy tuning method has been developed. The key challenges while monitoring multiple targets is frequency overlap. Here we describe the methods to circumvent the overlap, tune by use of nanoparticle (NP) and discuss the various fabrication and characterization methods to develop this technique. First sensors were fabricated using printed circuit board (PCB) technology and nickel and gold layers were electrodeposited onto the PCB sensors. An off-chip conjugation of gold NP's to molecular recognition elements (with verification technique) is described as well. A standard covalent immobilization of the molecular recognition elements is also discussed with quality control techniques. Finally use and verification of sensitivity and specificity is also presented. By use of gold NP's of various sizes, we have demonstrated the possibility and shown little loss of sensitivity and specificity in the molecular recognition of inflammatory markers as "model" targets for our tuning system. By selection of other sized NP's or NP's of various materials, the tuning effect can be further exploited. The novel platform technology developed could be utilized in critical care, clinical management and at home health and disease management. Copyright © 2013 Elsevier Inc. All rights reserved.
Fallahi, Shirzad; Mazar, Zahra Arab; Ghasemian, Mehrdad; Haghighi, Ali
2015-05-01
To compare analytical sensitivity and specificity of a newly described DNA amplification technique, LAMP and nested PCR assay targeting the RE and B1 genes for the detection of Toxoplasma gondii (T. gondii) DNA. The analytical sensitivity of LAMP and nested-PCR was obtained against10-fold serial dilutions of T. gondii DNA ranging from 1 ng to 0.01 fg. DNA samples of other parasites and human chromosomal DNA were used to determine the specificity of molecular assays. After testing LAMP and nested-PCR in duplicate, the detection limit of RE-LAMP, B1-LAMP, RE-nested PCR and B1-nested PCR assays was one fg, 100 fg, 1 pg and 10 pg of T. gondii DNA respectively. All the LAMP assays and nested PCRs were 100% specific. The RE-LAMP assay revealed the most sensitivity for the detection of T. gondii DNA. The obtained results demonstrate that the LAMP technique has a greater sensitivity for detection of T. gondii. Furthermore, these findings indicate that primers based on the RE are more suitable than those based on the B1 gene. However, the B1-LAMP assay has potential as a diagnostic tool for detection of T. gondii. Copyright © 2015 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.
Molecular detection of pathogens in water--the pros and cons of molecular techniques.
Girones, Rosina; Ferrús, Maria Antonia; Alonso, José Luis; Rodriguez-Manzano, Jesus; Calgua, Byron; Corrêa, Adriana de Abreu; Hundesa, Ayalkibet; Carratala, Anna; Bofill-Mas, Sílvia
2010-08-01
Pollution of water by sewage and run-off from farms produces a serious public health problem in many countries. Viruses, along with bacteria and protozoa in the intestine or in urine are shed and transported through the sewer system. Even in highly industrialized countries, pathogens, including viruses, are prevalent throughout the environment. Molecular methods are used to monitor viral, bacterial, and protozoan pathogens, and to track pathogen- and source-specific markers in the environment. Molecular techniques, specifically polymerase chain reaction-based methods, provide sensitive, rapid, and quantitative analytical tools with which to study such pathogens, including new or emerging strains. These techniques are used to evaluate the microbiological quality of food and water, and to assess the efficiency of virus removal in drinking and wastewater treatment plants. The range of methods available for the application of molecular techniques has increased, and the costs involved have fallen. These developments have allowed the potential standardization and automation of certain techniques. In some cases they facilitate the identification, genotyping, enumeration, viability assessment, and source-tracking of human and animal contamination. Additionally, recent improvements in detection technologies have allowed the simultaneous detection of multiple targets in a single assay. However, the molecular techniques available today and those under development require further refinement in order to be standardized and applicable to a diversity of matrices. Water disinfection treatments may have an effect on the viability of pathogens and the numbers obtained by molecular techniques may overestimate the quantification of infectious microorganisms. The pros and cons of molecular techniques for the detection and quantification of pathogens in water are discussed. (c) 2010 Elsevier Ltd. All rights reserved.
Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere
2015-12-01
Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.
Single-molecule spectroscopic methods.
Haustein, Elke; Schwille, Petra
2004-10-01
Being praised for the mere fact of enabling the detection of individual fluorophores a dozen years ago, single-molecule techniques nowadays represent standard methods for the elucidation of the structural rearrangements of biologically relevant macromolecules. Single-molecule-sensitive techniques, such as fluorescence correlation spectroscopy, allow real-time access to a multitude of molecular parameters (e.g. diffusion coefficients, concentration and molecular interactions). As a result of various recent advances, this technique shows promise even for intracellular applications. Fluorescence imaging can reveal the spatial localization of fluorophores on nanometer length scales, whereas fluorescence resonance energy transfer supports a wide range of different applications, including real-time monitoring of conformational rearrangements (as in protein folding). Still in their infancy, single-molecule spectroscopic methods thus provide unprecedented insights into basic molecular mechanisms. Copyright 2004 Elsevier Ltd.
Imaging-based molecular barcoding with pixelated dielectric metasurfaces.
Tittl, Andreas; Leitis, Aleksandrs; Liu, Mingkai; Yesilkoy, Filiz; Choi, Duk-Yong; Neshev, Dragomir N; Kivshar, Yuri S; Altug, Hatice
2018-06-08
Metasurfaces provide opportunities for wavefront control, flat optics, and subwavelength light focusing. We developed an imaging-based nanophotonic method for detecting mid-infrared molecular fingerprints and implemented it for the chemical identification and compositional analysis of surface-bound analytes. Our technique features a two-dimensional pixelated dielectric metasurface with a range of ultrasharp resonances, each tuned to a discrete frequency; this enables molecular absorption signatures to be read out at multiple spectral points, and the resulting information is then translated into a barcode-like spatial absorption map for imaging. The signatures of biological, polymer, and pesticide molecules can be detected with high sensitivity, covering applications such as biosensing and environmental monitoring. Our chemically specific technique can resolve absorption fingerprints without the need for spectrometry, frequency scanning, or moving mechanical parts, thereby paving the way toward sensitive and versatile miniaturized mid-infrared spectroscopy devices. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
Microwave Three-Wave Mixing Experiments for Chirality Determination: Current Status
NASA Astrophysics Data System (ADS)
Perez, Cristobal; Shubert, V. Alvin; Schmitz, David; Medcraft, Chris; Krin, Anna; Schnell, Melanie
2015-06-01
Microwave three-wave mixing experiments have been shown to provide a novel and sensitive way to generate and measure enantiomer-specific molecular signatures. The handedness of the sample can be obtained from the phase of the molecular free induction decay whereas the enantiomeric excess can be determined by the amplitude of the chiral signal. After the introduction of this technique by Patterson et al. remarkable improvements have been realized and experimental strategies for both absolute phase determination and enantiomeric excess have been presented. This technique has been also successfully implemented at higher microwave frequencies. Here we present the current status of this technique as well future directions and perspectives. This will be illustrated through our systematic study of chiral terpenes as well as preliminary results in molecular clusters. Patterson, D.; Schnell, M.; Doyle, J. M. Enantiomer-Specific Detection of Chiral Molecules via Microwave Spectroscopy. Nature 2013, 497, 475-477. Patterson, D.; Doyle, J. M. Sensitive Chiral Analysis via Microwave Three-Wave Mixing. Phys. Rev. Lett. 2013, 111, 023008. Shubert, V. A.; Schmitz, D.; Patterson, D.; Doyle, J. M.; Schnell, M. Identifying Enantiomers in Mixtures of Chiral Molecules with Broadband Microwave Spectroscopy. Angew. Chem. Int. Ed. 2014, 53, 1152-1155. Lobsiger, S.; Perez, C.; Evangelisti, L.; Lehmann, K. K.; Pate, B. H. Molecular Structure and Chirality Detection by Fourier Transform Microwave Spectroscopy. J. Phys. Chem. Lett. 2014, 6, 196-200.
Ortalli, Margherita; Attard, Luciano; Vanino, Elisa; Gaibani, Paolo; Vocale, Caterina; Rossini, Giada; Cagarelli, Roberto; Pierro, Anna; Billi, Patrizia; Mastroianni, Antonio; Di Cesare, Simona; Codeluppi, Mauro; Franceschini, Erica; Melchionda, Fraia; Gramiccia, Marina; Scalone, Aldo; Gentilomi, Giovanna A.; Landini, Maria P.
2017-01-01
The diagnosis of visceral leishmaniasis (VL) remains challenging, due to the limited sensitivity of microscopy, the poor performance of serological methods in immunocompromised patients and the lack of standardization of molecular tests. The aim of this study was to implement a combined diagnostic workflow by integrating serological and molecular tests with standardized clinical criteria. Between July 2013 and June 2015, the proposed workflow was applied to specimens obtained from 94 in-patients with clinical suspicion of VL in the Emilia-Romagna region, Northern Italy. Serological tests and molecular techniques were employed. Twenty-one adult patients (22%) had a confirmed diagnosis of VL by clinical criteria, serology and/or real-time polymerase chain reaction; 4 of these patients were HIV-positive. Molecular tests exhibited higher sensitivity than serological tests for the diagnosis of VL. In our experience, the rK39 immunochromatographic test was insufficiently sensitive for use as a screening test for the diagnosis of VL caused by L. infantum in Italy. However, as molecular tests are yet not standardized, further studies are required to identify an optimal screening test for Mediterranean VL. PMID:28832646
Molecular Weight Effects on the Viscoelastic Response of a Polyimide
NASA Technical Reports Server (NTRS)
Nicholson, Lee M.; Whitley, Karen S.; Gates, Thomas S.
2000-01-01
The effect of molecular weight on the viscoelastic performance of an advanced polymer (LaRC -SI) was investigated through the use of creep compliance tests. Testing consisted of short-term isothermal creep and recovery with the creep segments performed under constant load. The tests were conducted at three temperatures below the glass transition temperature of each material with different molecular weight. Through the use of time-aging-time superposition procedures, the material constants, material master curves and aging-related parameters were evaluated at each temperature for a given molecular weight. The time-temperature superposition technique helped to describe the effect of temperature on the timescale of the viscoelastic response of each molecular weight. It was shown that the low molecular weight materials have increased creep compliance and creep compliance rate, and are more sensitive to temperature than the high molecular weight materials. Furthermore, a critical molecular weight transition was observed to occur at a weight-average molecular weight of approximately 25000 g/mol below which, the temperature sensitivity of the time-temperature superposition shift factor increases rapidly.
Kang, Kyung Aih; Wang, Jianting
2014-12-07
Molecular sensing/imaging utilizing fluorophores has been one of the most frequently used techniques in biomedical research. As for any molecular imaging techniques, fluorescence mediated sensing always seeks for greater specificity and sensitivity. Since fluorophores emit fluorescence while their electron energy state changes, manipulating the local electromagnetic field around the fluorophores may be a way to enhance the specificity and sensitivity. Gold nanoparticles (GNPs) are known to form a very strong electromagnetic field on their surface [i.e., surface plasmon field (SPF)], upon receiving photonic energy. The level of fluorescence change by GNP-SPF may range from complete quenching to extensive enhancement, depending upon the SPF strength, excitation and emission wavelengths, and quantum yield of the fluorophore. Here, we report a novel design that utilizes BOTH fluorescence quenching and enhancement abilities of the GNP in one single nano-entity, providing high specificity and sensitivity. The construct utilizes a specially designed molecular dual-spacer that places the fluorphore at the location with an appropriate GNP-SFP strength before and after exposed to the biomarker. A model system to test the concept was an optical signal mediator activated by urokinase-type plasminogen activator (uPA; breast cancer secreting enzyme). The resulting contrast agent shows less than 10% of the natural fluorescence but, in the presence of uPA, its fluorescence emission is triggered and emits its fluorescence approximately twice of the natural form. This study demonstrated that our novel design of an optical contrast agent can be conditionally activated with enhanced sensitivity, using both quenching and enhancement phenomena of fluorophores in the electromagnetic field of the appropriate strengths (in this case, locally generated by the GNP-SPF). This entity is similar to molecular beacon in terms of specificity but with greater sensitivity. In addition, it is not restricted to only DNA or RNA sensing but for any designs that cause the change in the distance between the fluorophore and GNP, upon the time of encountering biomarker of interest.
NASA Astrophysics Data System (ADS)
Melquíades, Mônica C.; Aderne, Rian; Cuin, Alexandre; Quirino, Welber G.; Cremona, Marco; Legnani, Cristiano
2017-07-01
In this work, a near infrared (NIR) sensitive molecule, Tin(II)2,3-naphthalocyanine (SnNc) was characterized by different techniques. UV-Vis spectroscopy and cyclic voltammetry were performed in order to determine the absorption spectrum, the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbital (LUMO) energies of this molecule deposited in form of thin films. We found energies of 5.0 ± 0.1 eV and 3.7 ± 0.1 eV for HOMO and LUMO, respectively. The charge carrier mobility was also investigated by space charge limit current technique showing values of μh (8.8 ± 0.1) x 10-5 cm2V-1s-1. SnNc alone or blended with fullerene was used as efficient NIR sensitive layer due to its absorption around 875 nm. The crystalline structure of SnNc was studied by X-ray powder diffraction, showing a monoclinic system and P21/c space group, with cell parameters a = (15.948 ± 6) Å, b = (15.818 ± 2) Å, c = (14.649 ± 1) Å and β = (67.096 ± 6) Å. Desorption/Ionization-Time of Flight Mass Spectrometry (LDI-TOFMS) technique was employed to obtain information of molecular structure of the SnNc in thin film, showing that the thin film of the SnNc has no dimer formation. Due to its absorption around 875 nm, SnNc blended with fullerene was used as efficient NIR sensitive layer in the fabrication of an organic up-conversion device. When the device is submitted to IR radiation, a gain of about 133% was observed in the luminous efficiency when compared to values without IR irradiation.
ERIC Educational Resources Information Center
Bornhorst, Joshua A.; Deibel, Michael A.; Mulnix, Amy B.
2004-01-01
A novel experimental sequence for the advanced undergraduate laboratory course has been developed at Earlham College. Utilizing recent improvements in molecular techniques for a time-sensitive environment, undergraduates were able to create a chimera of a selected gene and green fluorescent protein (GFP) in a bacterial expression plasmid over the…
Molecular diagnosis of toxoplasmosis in immunocompromised patients.
Robert-Gangneux, Florence; Belaz, Sorya
2016-08-01
Toxoplasmosis in immunocompromised patients is associated with a high mortality rate. Molecular techniques are important tools to diagnose acute disease in immunocompromised patients, but there are various methods with variable efficiency. Some of them have been validated for the diagnosis of congenital toxoplasmosis, but the impact of their use has not been evaluated in immunocompromised patients. Toxoplasmosis is of increasing importance in non-HIV immunocompromised patients. In addition, the picture of disease shows greater severity in South America, both in immunocompetent study participants and in congenitally infected infants. These epidemiological differences could influence the sensitivity of diagnostic methods. This review analyzes recent data on molecular diagnosis and compares them with older ones, in light of progress gained in molecular techniques and of recent epidemiological findings. Most recent studies were conducted in South America and used PCR targeting the B1 gene. PCR on blood could allow diagnosing a significant proportion of patients with ocular toxoplasmosis in Brazil. Quantitative PCR methods with specific probes should be used to improve sensitivity and warrant specificity. Performance of quantitative PCR targeting the repeated 529 bp sequence for the diagnosis of toxoplasmosis in immunocompromised patients needs evaluation in field studies in South America and in western countries.
Molecular beacon probes-base multiplex NASBA Real-time for detection of HIV-1 and HCV.
Mohammadi-Yeganeh, S; Paryan, M; Mirab Samiee, S; Kia, V; Rezvan, H
2012-06-01
Developed in 1991, nucleic acid sequence-based amplification (NASBA) has been introduced as a rapid molecular diagnostic technique, where it has been shown to give quicker results than PCR, and it can also be more sensitive. This paper describes the development of a molecular beacon-based multiplex NASBA assay for simultaneous detection of HIV-1 and HCV in plasma samples. A well-conserved region in the HIV-1 pol gene and 5'-NCR of HCV genome were used for primers and molecular beacon design. The performance features of HCV/HIV-1 multiplex NASBA assay including analytical sensitivity and specificity, clinical sensitivity and clinical specificity were evaluated. The analysis of scalar concentrations of the samples indicated that the limit of quantification of the assay was <1000 copies/ml for HIV-1 and <500 copies/ml for HCV with 95% confidence interval. Multiplex NASBA assay showed a 98% sensitivity and 100% specificity. The analytical specificity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes detected all HCV genotypes and all major variants of HIV-1. This method may represent a relatively inexpensive isothermal method for detection of HIV-1/HCV co-infection in monitoring of patients.
Liu, Jie; Kabir, Furqan; Manneh, Jainaba; Lertsethtakarn, Paphavee; Begum, Sharmin; Gratz, Jean; Becker, Steve M; Operario, Darwin J; Taniuchi, Mami; Janaki, Lalitha; Platts-Mills, James A; Haverstick, Doris M; Kabir, Mamun; Sobuz, Shihab U; Nakjarung, Kaewkanya; Sakpaisal, Pimmada; Silapong, Sasikorn; Bodhidatta, Ladaporn; Qureshi, Shahida; Kalam, Adil; Saidi, Queen; Swai, Ndealilia; Mujaga, Buliga; Maro, Athanasia; Kwambana, Brenda; Dione, Michel; Antonio, Martin; Kibiki, Gibson; Mason, Carl J; Haque, Rashidul; Iqbal, Najeeha; Zaidi, Anita K M; Houpt, Eric R
2014-08-01
Childhood diarrhoea can be caused by many pathogens that are difficult to assay in the laboratory. Molecular diagnostic techniques provide a uniform method to detect and quantify candidate enteropathogens. We aimed to develop and assess molecular tests for identification of enteropathogens and their association with disease. We developed and assessed molecular diagnostic tests for 15 enteropathogens across three platforms-PCR-Luminex, multiplex real-time PCR, and TaqMan array card-at five laboratories worldwide. We judged the analytical and clinical performance of these molecular techniques against comparator methods (bacterial culture, ELISA, and PCR) using 867 diarrhoeal and 619 non-diarrhoeal stool specimens. We also measured molecular quantities of pathogens to predict the association with diarrhoea, by univariate logistic regression analysis. The molecular tests showed very good analytical and clinical performance at all five laboratories. Comparator methods had limited sensitivity compared with the molecular techniques (20-85% depending on the target) but good specificity (median 97·3%, IQR 96·5-98·9; mean 95·2%, SD 9·1). Positive samples by comparator methods usually had higher molecular quantities of pathogens than did negative samples, across almost all platforms and for most pathogens (p<0·05). The odds ratio for diarrhoea at a given quantity (measured by quantification cycle, Cq) showed that for most pathogens associated with diarrhoea-including Campylobacter jejuni and Campylobacter coli, Cryptosporidium spp, enteropathogenic Escherichia coli, heat-stable enterotoxigenic E coli, rotavirus, Shigella spp and enteroinvasive E coli, and Vibrio cholerae-the strength of association with diarrhoea increased at higher pathogen loads. For example, Shigella spp at a Cq range of 15-20 had an odds ratio of 8·0 (p<0·0001), but at a Cq range of 25-30 the odds ratio fell to 1·7 (p=0·043). Molecular diagnostic tests can be implemented successfully and with fidelity across laboratories around the world. In the case of diarrhoea, these techniques can detect pathogens with high sensitivity and ascribe diarrhoeal associations based on quantification, including in mixed infections, providing rich and unprecedented measurements of infectious causes. Bill & Melinda Gates Foundation Next Generation Molecular Diagnostics Project. Copyright © 2014 Elsevier Ltd. All rights reserved.
AlWakeel, Suaad S
2017-09-01
This study aimed to determine the bacterial species colonizing the nasal and oropharyngeal mucosa of fuel workers in Central Riyadh, Saudi Arabia on a microbiological and molecular level. Throat and nasal swab samples were obtained from 29 fuel station attendants in the period of time extending from March to May 2014 in Riyadh, Saudi Arabia. Microbiological identification techniques were utilized to identify the bacterial species isolated. Antibiotic sensitivity was assessed for each of the bacterial isolates. Molecular identification techniques based on PCR analysis of specific genomic sequences was conducted and was the basis on which phylogeny representation was done for 10 randomly selected samples of the isolates. Blood was drawn and a complete blood count was conducted to note the hematological indices for each of the study participants. Nineteen bacterial species were isolated from both the nasal cavity and the oropharynx including Streptococcus thoraltensis , alpha-hemolytic streptococci, Staphylococcus hominis , coagulase-negative staphylococci, Leuconostoc mesenteroides , Erysipelothrix rhusiopathiae and several others. We found 100% sensitivity of the isolates to ciprofloxacin, cefuroxime and gentamicin. Whereas cefotaxime and azithromycin posted sensitivities of 85.7% and 91.4%, respectively. Low sensitivities (<60% sensitivity) to the antibiotics ampicillin, erythromycin, clarithromycin and norfloxacin were observed. Ninety-seven percent similarity to the microbial bank species was noted when the isolates were compared to it. Most hematological indices recorded were within the normal range. In conclusion, exposure to toxic fumes and compounds within fuel products may be a contributing factor to bacterial colonization of the respiratory tract in fuel workers.
Flexible scintillator autoradiography for tumor margin inspection using 18F-FDG
NASA Astrophysics Data System (ADS)
Vyas, K. N.; Grootendorst, M.; Mertzanidou, T.; Macholl, S.; Stoyanov, D.; Arridge, S. R.; Tuch, D. S.
2018-03-01
Autoradiography potentially offers high molecular sensitivity and spatial resolution for tumor margin estimation. However, conventional autoradiography requires sectioning the sample which is destructive and labor-intensive. Here we describe a novel autoradiography technique that uses a flexible ultra-thin scintillator which conforms to the sample surface. Imaging with the flexible scintillator enables direct, high-resolution and high-sensitivity imaging of beta particle emissions from targeted radiotracers. The technique has the potential to identify positive tumor margins in fresh unsectioned samples during surgery, eliminating the processing time demands of conventional autoradiography. We demonstrate the feasibility of the flexible autoradiography approach to directly image the beta emissions from radiopharmaceuticals using lab experiments and GEANT-4 simulations to determine i) the specificity for 18F compared to 99mTc-labeled tracers ii) the sensitivity to detect signal from various depths within the tissue. We found that an image resolution of 1.5 mm was achievable with a scattering background and we estimate a minimum detectable activity concentration of 0.9 kBq/ml for 18F. We show that the flexible autoradiography approach has high potential as a technique for molecular imaging of tumor margins using 18F-FDG in a tumor xenograft mouse model imaged with a radiation-shielded EMCCD camera. Due to the advantage of conforming to the specimen, the flexible scintillator showed significantly better image quality in terms of tumor signal to whole-body background noise compared to rigid and optimally thick CaF2:Eu and BC400. The sensitivity of the technique means it is suitable for clinical translation.
Impurity measurements in semiconductor materials using trace element accelerator mass spectrometry
NASA Astrophysics Data System (ADS)
McDaniel, F. D.; Datar, S. A.; Nigam, M.; Ravi Prasad, G. V.
2002-05-01
Accelerator mass spectrometry (AMS) is commonly used to determine the abundance ratios of long-lived isotopes such as 10B, 14C, 36Cl, 129I, etc. to their stable counterparts at levels as low as 10 -16. Secondary ion mass spectrometry (SIMS) is routinely used to determine impurity levels in materials by depth profiling techniques. Trace-element accelerator mass spectrometry (TEAMS) is a combination of AMS and SIMS, presently being used at the University of North Texas, for high-sensitivity (ppb) impurity analyses of stable isotopes in semiconductor materials. The molecular break-up characteristics of AMS are used with TEAMS to remove the molecular interferences present in SIMS. Measurements made with different substrate/impurity combinations demonstrate that TEAMS has higher sensitivity for many elements than other techniques such as SIMS and can assist with materials characterization issues. For example, measurements of implanted As in the presence of Ge in Ge xSi 1- x/Si is difficult with SIMS because of molecular interferences from 74GeH, 29Si 30Si 16O, etc. With TEAMS, the molecular interferences are removed and higher sensitivities are obtained. Measured substrates include Si, SiGe, CoSi 2, GaAs and GaN. Measured impurities include B, N, F, Mg, P, Cl, Cr, Fe, Ni, Co, Cu, Zn, Ge, As, Se, Mo, Sn and Sb. A number of measurements will be presented to illustrate the range and power of TEAMS.
Yola, Mehmet Lütfi; Eren, Tanju; Atar, Necip
2014-10-15
The molecular imprinting technique depends on the molecular recognition. It is a polymerization method around the target molecule. Hence, this technique creates specific cavities in the cross-linked polymeric matrices. In present study, a sensitive imprinted electrochemical biosensor based on Fe@Au nanoparticles (Fe@AuNPs) involved in 2-aminoethanethiol (2-AET) functionalized multi-walled carbon nanotubes (f-MWCNs) modified glassy carbon (GC) electrode was developed for determination of cefexime (CEF). The results of X-ray photoelectron spectroscopy (XPS) and reflection-absorption infrared spectroscopy (RAIRS) confirmed the formation of the developed surfaces. CEF imprinted film was constructed by cyclic voltammetry (CV) for 9 cycles in the presence of 80 mM pyrrole in phosphate buffer solution (pH 6.0) containing 20mM CEF. The developed electrochemical biosensor was validated according to the International Conference on Harmonisation (ICH) guideline and found to be linear, sensitive, selective, precise and accurate. The linearity range and the detection limit were obtained as 1.0 × 10(-10)-1.0 × 10(-8)M and 2.2 × 10(-11)M, respectively. The developed CEF imprinted sensor was successfully applied to real samples such as human plasma. In addition, the stability and reproducibility of the prepared molecular imprinted electrode were investigated. The excellent long-term stability and reproducibility of the prepared CEF imprinted electrodes make them attractive in electrochemical sensors. Copyright © 2014 Elsevier B.V. All rights reserved.
Circumstellar radio molecular lines
NASA Technical Reports Server (NTRS)
NGUYEN-QUANG-RIEU
1987-01-01
Radio molecular lines appear to be useful probes into the stellar environment. Silicon oxide masers provide information on the physical conditions in the immediate vicinity of the stellar photosphere. Valuable information on the physics operating in the envelope of IRC + 10216 was recently obtained by high sensitivity observations and detailed theoretical analyses. Infrared speckle interferometry in the molecular lines and in the continuum is helpful in the investigation of the inner region of the envelope. These techniques are discussed in terms of late-type star mass loss.
Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Gildea, Sarah; Cullinane, Ann
2016-03-01
Equine influenza (EI) is a highly contagious disease caused by viruses of the H3N8 subtype. The rapid diagnosis of EI is essential to reduce the disease spread. Many rapid antigen detection (RAD) tests for diagnosing human influenza are available, but their ability to diagnose EI has not been systematically evaluated. The aim of this study was to compare the performance of 22 RAD tests in the diagnosis of EI. The 22 RAD tests were performed on fivefold serial dilutions of EI virus to determine their detection limits. The four most sensitive RAD tests (ImmunoAce Flu, BD Flu examan, Quick chaser Flu A, B and ESPLINE Influenza A&B-N) were further evaluated using nasopharyngeal samples collected from experimentally infected and naturally infected horses. The results were compared to those obtained using molecular tests. The detection limits of the 22 RAD tests varied hugely. Even the four RAD tests showing the best sensitivity were 125-fold less sensitive than the molecular techniques. The duration of virus detection in the experimentally infected horses was shorter using the RAD tests than using the molecular techniques. The RAD tests detected between 27% and 73% of real-time RT-PCR-positive samples from naturally infected horses. The study demonstrated the importance of choosing the right RAD tests as only three of 22 were fit for diagnosing EI. It was also indicated that even RAD tests with the highest sensitivity serve only as an adjunct to molecular tests because of the potential for false-negative results. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Renault, Ilana Zalcberg; Scholl, Vanesa; Hassan, Rocio; Capelleti, Paola; de Lima, Marcos; Cortes, Jorge
2011-01-01
Tyrosine kinase inhibitors have changed the management and outcomes of chronic myeloid leukemia patients. Quantitative polymerase chain reaction is used to monitor molecular responses to tyrosine kinase inhibitors. Molecular monitoring represents the most sensitive tool to judge chronic myeloid leukemia disease course and allows early detection of relapse. Evidence of achieving molecular response is important for several reasons: 1. early molecular response is associated with major molecular response rates at 18-24 months; 2. patients achieving major molecular response are less likely to lose their complete cytogenetic response; 3. a durable, stable major molecular response is associated with increased progression-free survival. However, standardization of molecular techniques is still challenging. PMID:23049363
Molecular diagnosis of strongyloidiasis in a population of an endemic area through nested-PCR.
Sharifdini, Meysam; Keyhani, Amir; Eshraghian, Mohammad Reza; Beigom Kia, Eshrat
2018-01-01
This study is aimed to diagnose and analyze strongyloidiasis in a population of an endemic area of Iran using nested-PCR, coupled with parasitological methods. Screening of strongyloidiasis infected people using reliable diagnostic techniques are essential to decrease the mortality and morbidity associated with this infection. Molecular methods have been proved to be highly sensitive and specific for detection of Strongyloides stercoralis in stool samples. A total of 155 fresh single stool samples were randomly collected from residents of north and northwest of Khouzestan Province, Iran. All samples were examined by parasitological methods including formalin-ether concentration and nutrient agar plate culture, and molecular method of nested-PCR. Infections with S. stercoralis were analyzed according to demographic criteria. Based on the results of nested-PCR method 15 cases (9.7%) were strongyloidiasis positive. Nested-PCR was more sensitive than parasitological techniques on single stool sampling. Elderly was the most important population index for higher infectivity with S. stercoralis . In endemic areas of S. stercoralis , old age should be considered as one of the most important risk factors of infection, especially among the immunosuppressed individuals.
Label-free optical imaging of nonfluorescent molecules by stimulated radiation.
Min, Wei
2011-12-01
Imaging contrasts other than fluorescence are highly desirable for label-free detection and interrogation of nonfluorescent molecular species inside live cells, tissues, and organisms. The recently developed stimulated Raman scattering (SRS) and stimulated emission microscopy techniques provide sensitive and specific contrast mechanisms for nonfluorescent species, by employing the light amplification aspect of stimulated radiation. Compared to their spontaneous counterparts, stimulated radiation can enhance the imaging performance significantly, making the previously 'dark' molecules observable. Here we review and summarize the underlying principles of this emerging class of molecular imaging techniques. Copyright © 2011 Elsevier Ltd. All rights reserved.
Quantitative imaging of disease signatures through radioactive decay signal conversion
Thorek, Daniel LJ; Ogirala, Anuja; Beattie, Bradley J; Grimm, Jan
2013-01-01
In the era of personalized medicine there is an urgent need for in vivo techniques able to sensitively detect and quantify molecular activities. Sensitive imaging of gamma rays is widely used, but radioactive decay is a physical constant and signal is independent of biological interactions. Here we introduce a framework of novel targeted and activatable probes excited by a nuclear decay-derived signal to identify and measure molecular signatures of disease. This was accomplished utilizing Cerenkov luminescence (CL), the light produced by β-emitting radionuclides such as clinical positron emission tomography (PET) tracers. Disease markers were detected using nanoparticles to produce secondary Cerenkov-induced fluorescence. This approach reduces background signal compared to conventional fluorescence imaging. In addition to information from a PET scan, we demonstrate novel medical utility by quantitatively determining prognostically relevant enzymatic activity. This technique can be applied to monitor other markers and facilitates a shift towards activatable nuclear medicine agents. PMID:24013701
The role of rapid antigen testing for influenza in the era of molecular diagnostics.
Dale, Suzanne E
2010-08-01
Rapid antigen testing for influenza has been both maligned and revered since its conception. Microbiologists have long lamented the lack of sensitivity of commercial rapid influenza detection tests (RIDTs), whereas many clinicians have eschewed their utility by emphasizing the value of definitely diagnosing influenza at the patient's bedside. RIDTs, although quick and easy to perform, are widely accepted as being less sensitive than traditional culture techniques and newer molecular methods, including reverse-transcription polymerase chain reaction (RT-PCR). Moreover, the performance characteristics of RIDTs vary widely, and their applications as clinical diagnostic tools are not well understood. In contrast, traditional techniques are time consuming and require significant expertise to perform. Often, the delay in diagnosing influenza through these methods has little impact on patient care. The benefits of achieving a diagnosis of influenza at the point of care are numerous and include increased access to appropriate antivirals, appropriate patient cohorting for infection control purposes, and better resource utilization. Therefore, it behooves the microbiology community to communicate these issues to clinicians and to work to improve the sensitivity of RIDTs.
Overview of hybridization and detection techniques.
Hilario, Elena
2007-01-01
A misconception regarding the sensitivity of nonradioactive methods for screening genomic DNA libraries often hinders the establishment of these environmentally friendly techniques in molecular biology laboratories. Nonradioactive probes, properly prepared and quantified, can detect DNA target molecules to the femtomole range. However, appropriate hybridization techniques and detection methods should also be adopted for an efficient use of nonradioactive techniques. Detailed descriptions of genomic library handling before and during the nonradioactive hybridization and detection are often omitted from publications. This chapter aims to fill this void by providing a collection of technical tips on hybridization and detection techniques.
Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios
2014-01-01
Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions.
Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A.; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios
2014-01-01
Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions. PMID:24812614
Portable SERS sensor for malachite green and other small dye molecules
NASA Astrophysics Data System (ADS)
Qiu, Suyan; Zhao, Fusheng; Li, Jingting; Shih, Wei-Chuan
2017-02-01
Sensitive detection of specific chemicals on site can be extremely powerful in many fields. Owing to its molecular fingerprinting capability, surface-enhanced Raman scattering has been one of the technological contenders. In this paper, we describe the novel use of DNA topological nanostructure on nanoporous gold nanoparticle (NPG-NP) array chip for chemical sensing. NPG-NP features large surface area and high-density plasmonic field enhancement known as "hotspots". Hence, NPG-NP array chip has found many applications in nanoplasmonic sensor development. This technique can provide novel label-free molecular sensing capability and enables high sensitivity and specificity detection using a portable Raman spectrometer.
NASA Astrophysics Data System (ADS)
Ozturk, Mehmet Saadeddin
Optical microscopy has been one of the essential tools for biological studies for decades, however, its application areas was limited to superficial investigation due to strong scattering in live tissues. Even though advanced techniques such as confocal or multiphoton methods have been recently developed to penetrate beyond a few hundreds of microns deep in tissues, they still cannot perform in the mesoscopic regime (millimeter scale) without using destructive sample preparation protocols such as clearing techniques. They provide rich cellular information; however, they cannot be readily employed to investigate the biological processes at larger scales. Herein, we will present our effort to establish a novel imaging approach that can quantify molecular expression in intact tissues, well beyond the current microscopy depth limits. Mesoscopic Fluorescence Molecular Tomography (MFMT) is an emerging imaging modality that offers unique potential for the non-invasive molecular assessment of thick in-vitro and in-vivo live tissues. This novel imaging modality is based on an optical inverse problem that allows for retrieval of the quantitative spatial distribution of fluorescent tagged bio-markers at millimeter depth. MFMT is well-suited for in-vivo subsurface tissue imaging and thick bio-printed specimens due to its high sensitivity and fast acquisition times, as well as relatively large fields of view. Herein, we will first demonstrate the potential of this technique using our first generation MFMT system applied to multiplexed reporter gene imaging (in-vitro) and determination of Photodynamic Therapy (PDT) agent bio-distribution in a mouse model (in-vivo). Second, we will present the design rationale, in silico benchmarking, and experimental validation of a second generation MFMT (2GMFMT) system. We will demonstrate the gain in resolution and sensitivity achieved due to the de-scanned dense detector configuration implemented. The potential of this novel platform will be showcased by applying it to the longitudinal assessment of Ink-Jet Bio-Printed tumor models. This preliminary investigation focuses on monitoring four patient-derived glioblastoma multiforme (GBM) spheroids within their bioreactor for up to 70 days and following their volume change prior to and after exposure to a cytotoxic drug. Overall, our studies indicate that 2GMFMT is a powerful technique for in-vitro and in-vivo thick tissue molecular imaging applications due to its high resolution, fast tomographic imaging capability, and high sensitivity.
Brennan, T.M.; Hammons, B.E.; Tsao, J.Y.
1992-12-15
A method for on-line accurate monitoring and precise control of molecular beam epitaxial growth of Groups III-III-V or Groups III-V-V layers in an advanced semiconductor device incorporates reflection mass spectrometry. The reflection mass spectrometry is responsive to intentional perturbations in molecular fluxes incident on a substrate by accurately measuring the molecular fluxes reflected from the substrate. The reflected flux is extremely sensitive to the state of the growing surface and the measurements obtained enable control of newly forming surfaces that are dynamically changing as a result of growth. 3 figs.
Brennan, Thomas M.; Hammons, B. Eugene; Tsao, Jeffrey Y.
1992-01-01
A method for on-line accurate monitoring and precise control of molecular beam epitaxial growth of Groups III-III-V or Groups III-V-V layers in an advanced semiconductor device incorporates reflection mass spectrometry. The reflection mass spectrometry is responsive to intentional perturbations in molecular fluxes incident on a substrate by accurately measuring the molecular fluxes reflected from the substrate. The reflected flux is extremely sensitive to the state of the growing surface and the measurements obtained enable control of newly forming surfaces that are dynamically changing as a result of growth.
Fourier transform ion cyclotron resonance mass spectrometry
NASA Astrophysics Data System (ADS)
Marshall, Alan G.
1998-06-01
As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.
Peeters, Bart; Herijgers, Paul; Beuselinck, Kurt; Peetermans, Willy E.; Herregods, Marie-Christin
2016-01-01
Identification of the causative pathogen of infective endocarditis (IE) is crucial for adequate management and therapy. A broad-range PCR-electrospray ionization mass spectrometry (PCR-ESI-MS) technique was compared with broad-spectrum 16S rRNA PCR and amplicon sequencing (16S rRNA PCR) for the detection of bacterial pathogens in 40 heart valves obtained from 34 definite infective endocarditis patients according to the modified Duke criteria and six nonendocarditis patients. Concordance between the two molecular techniques was 98% for being positive or negative, 97% for concordant identification up to the genus level, and 77% for concordant identification up to the species level. Sensitivity for detecting the causative pathogen (up to the genus level) in excised heart valves was 88% for 16S rRNA PCR and 85% for PCR-ESI-MS; the specificity was 83% for both methods. The two molecular techniques were significantly more sensitive than valve culture (18%) and accurately identified bacteria in excised heart valves. In eight patients with culture-negative IE, the following results were obtained: concordant detection of Coxiella burnetii (n = 2), Streptococcus gallolyticus (n = 1), Propionibacterium acnes (n = 1), and viridans group streptococci (n = 1) by both molecular tests, detection of P. acnes by PCR-ESI-MS whereas the 16S rRNA PCR was negative (n = 1), and a false-negative result by both molecular techniques (n = 2). In one case of IE caused by viridans streptococci, PCR-ESI-MS was positive for Enterococcus spp. The advantages of PCR-ESI-MS compared to 16S rRNA PCR are its automated workflow and shorter turnaround times. PMID:27629895
Zhang, Xiaojuan; Reeves, Daniel B; Perreard, Irina M; Kett, Warren C; Griswold, Karl E; Gimi, Barjor; Weaver, John B
2013-12-15
Functionalized magnetic nanoparticles (mNPs) have shown promise in biosensing and other biomedical applications. Here we use functionalized mNPs to develop a highly sensitive, versatile sensing strategy required in practical biological assays and potentially in vivo analysis. We demonstrate a new sensing scheme based on magnetic spectroscopy of nanoparticle Brownian motion (MSB) to quantitatively detect molecular targets. MSB uses the harmonics of oscillating mNPs as a metric for the freedom of rotational motion, thus reflecting the bound state of the mNP. The harmonics can be detected in vivo from nanogram quantities of iron within 5s. Using a streptavidin-biotin binding system, we show that the detection limit of the current MSB technique is lower than 150 pM (0.075 pmole), which is much more sensitive than previously reported techniques based on mNP detection. Using mNPs conjugated with two anti-thrombin DNA aptamers, we show that thrombin can be detected with high sensitivity (4 nM or 2 pmole). A DNA-DNA interaction was also investigated. The results demonstrated that sequence selective DNA detection can be achieved with 100 pM (0.05 pmole) sensitivity. The results of using MSB to sense these interactions, show that the MSB based sensing technique can achieve rapid measurement (within 10s), and is suitable for detecting and quantifying a wide range of biomarkers or analytes. It has the potential to be applied in variety of biomedical applications or diagnostic analyses. © 2013 Elsevier B.V. All rights reserved.
Youker, Robert T.; Teng, Haibing
2014-01-01
Abstract. Quantitative analysis of protein complex stoichiometries and mobilities are critical for elucidating the mechanisms that regulate cellular pathways. Fluorescence fluctuation spectroscopy (FFS) techniques can measure protein dynamics, such as diffusion coefficients and formation of complexes, with extraordinary precision and sensitivity. Complete calibration and characterization of the microscope instrument is necessary in order to avoid artifacts during data acquisition and to capitalize on the full capabilities of FFS techniques. We provide an overview of the theory behind FFS techniques, discuss calibration procedures, provide protocols, and give practical considerations for performing FFS experiments. One important parameter recovered from FFS measurements is the relative molecular brightness that can correlate with oligomerization. Three methods for measuring molecular brightness (fluorescence correlation spectroscopy, photon-counting histogram, and number and brightness analysis) recover similar values when measuring samples under ideal conditions in vitro. However, examples are given illustrating that these different methods used for calculating molecular brightness of fluorescent molecules in cells are not always equivalent. Methods relying on spot measurements are more prone to bleaching and movement artifacts that can lead to underestimation of brightness values. We advocate for the use of multiple FFS techniques to study molecular brightnesses to overcome and compliment limitations of individual techniques. PMID:25260867
NASA Astrophysics Data System (ADS)
Hodges, James N.; Siller, Brian; McCall, Benjamin J.
2015-06-01
The technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy, or NICE-OHVMS, has been used to great effect to precisely and accurately measure a variety of molecular ion transitions from species such as H_3^+, CH_5^+, HeH^+, and HCO^+, achieving MHz or in some cases sub-MHz uncertainty. It is a powerful technique, but a complete theoretical understanding of the complex NICE-OHVMS lineshape is needed to fully unlock its potential. NICE-OHVMS is the direct result of the combination of the highly sensitive spectroscopic technique Noise Immune Cavity Enhanced Optical Heterodyne Molecular Spectroscopy(NICE-OHMS) with Velocity Modulation Spectroscopy(VMS), applying the most sensitive optical detection method with ion species selectivity. The theoretical underpinnings of NICE-OHMS lineshapes are well established, as are those of VMS. This presentation is the logical extension of those two preceding bodies of work. Simulations of NICE-OHVMS lineshapes under a variety of conditions and fits of experimental data to the model are presented. The significance and accuracy of the various inferred parameters, along with the prospect of using them to extract additional information from observed transitions, are discussed. J.~N. Hodges, et al. J. Chem. Phys. (2013), 139, 164201. A.~J. Perry, et al. J. Chem. Phys. (2014), 141, 101101. K.~N. Crabtree, et al. Chem. Phys. Lett. (2012), 551, 1-6. F.~M. Schmidt, et al. J. Opt. Soc. Amer. A (2008), 24, 1392--1405. J.~W. Farley, J. Chem. Phys. (1991), 95, 5590--5602.
Magnetomotive Molecular Nanoprobes
John, Renu; Boppart, Stephen A.
2012-01-01
Tremendous developments in the field of biomedical imaging in the past two decades have resulted in the transformation of anatomical imaging to molecular-specific imaging. The main approaches towards imaging at a molecular level are the development of high resolution imaging modalities with high penetration depths and increased sensitivity, and the development of molecular probes with high specificity. The development of novel molecular contrast agents and their success in molecular optical imaging modalities have lead to the emergence of molecular optical imaging as a more versatile and capable technique for providing morphological, spatial, and functional information at the molecular level with high sensitivity and precision, compared to other imaging modalities. In this review, we discuss a new class of dynamic contrast agents called magnetomotive molecular nanoprobes for molecular-specific imaging. Magnetomotive agents are superparamagnetic nanoparticles, typically iron-oxide, that are physically displaced by the application of a small modulating external magnetic field. Dynamic phase-sensitive position measurements are performed using any high resolution imaging modality, including optical coherence tomography (OCT), ultrasonography, or magnetic resonance imaging (MRI). The dynamics of the magnetomotive agents can be used to extract the biomechanical tissue properties in which the nanoparticles are bound, and the agents can be used to deliver therapy via magnetomotive displacements to modulate or disrupt cell function, or hyperthermia to kill cells. These agents can be targeted via conjugation to antibodies, and in vivo targeted imaging has been shown in a carcinogen-induced rat mammary tumor model. The iron-oxide nanoparticles also exhibit negative T2 contrast in MRI, and modulations can produce ultrasound imaging contrast for multimodal imaging applications. PMID:21517766
Pump-probe optical microscopy for imaging nonfluorescent chromophores.
Wei, Lu; Min, Wei
2012-06-01
Many chromophores absorb light intensely but have undetectable fluorescence. Hence microscopy techniques other than fluorescence are highly desirable for imaging these chromophores inside live cells, tissues, and organisms. The recently developed pump-probe optical microscopy techniques provide fluorescence-free contrast mechanisms by employing several fundamental light-molecule interactions including excited state absorption, stimulated emission, ground state depletion, and the photothermal effect. By using the pump pulse to excite molecules and the subsequent probe pulse to interrogate the created transient states on a laser scanning microscope, pump-probe microscopy offers imaging capability with high sensitivity and specificity toward nonfluorescent chromophores. Single-molecule sensitivity has even been demonstrated. Here we review and summarize the underlying principles of this emerging class of molecular imaging techniques.
Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan
2014-01-01
Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery.
Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan
2014-01-01
Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery. PMID:25250092
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A.; García, Paquita; Sall, Amadou A.; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
Objective We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. Study Design For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Results Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. Conclusion This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles. PMID:22570700
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A; García, Paquita; Sall, Amadou A; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles.
2014-01-01
Summary Vibrational transitions contain some of the richest fingerprints of molecules and materials, providing considerable physicochemical information. Vibrational transitions can be characterized by different spectroscopies, and alternatively by several imaging techniques enabling to reach sub-microscopic spatial resolution. In a quest to always push forward the detection limit and to lower the number of needed vibrational oscillators to get a reliable signal or imaging contrast, surface plasmon resonances (SPR) are extensively used to increase the local field close to the oscillators. Another approach is based on maximizing the collective response of the excited vibrational oscillators through molecular coherence. Both features are often naturally combined in vibrational nonlinear optical techniques. In this frame, this paper reviews the main achievements of the two most common vibrational nonlinear optical spectroscopies, namely surface-enhanced sum-frequency generation (SE-SFG) and surface-enhanced coherent anti-Stokes Raman scattering (SE-CARS). They can be considered as the nonlinear counterpart and/or combination of the linear surface-enhanced infrared absorption (SEIRA) and surface-enhanced Raman scattering (SERS) techniques, respectively, which are themselves a branching of the conventional IR and spontaneous Raman spectroscopies. Compared to their linear equivalent, those nonlinear vibrational spectroscopies have proved to reach higher sensitivity down to the single molecule level, opening the way to astonishing perspectives for molecular analysis. PMID:25551056
When insect endosymbionts and plant endophytes mediate biological control outcomes
USDA-ARS?s Scientific Manuscript database
The identification of endosymbionts and endophytes within insect and plant tissues, respectively, has increased exponentially over the past 10-15 years, enabled largely by the proliferation of sensitive molecular techniques and publicly accessible databases of nucleotide sequences. However, the rate...
Fluorescence Molecular Tomography: Principles and Potential for Pharmaceutical Research
Stuker, Florian; Ripoll, Jorge; Rudin, Markus
2011-01-01
Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated labeling strategies that have been developed for selectively labeling target molecules. More recently, two and three-dimensional optical imaging methods have also been applied to monitor biological processes in intact biological organisms such as animals or even humans. These whole body optical imaging approaches have to cope with the fact that biological tissue is a highly scattering and absorbing medium. As a consequence, light propagation in tissue is well described by a diffusion approximation and accurate reconstruction of spatial information is demanding. While in vivo optical imaging is a highly sensitive method, the signal is strongly surface weighted, i.e., the signal detected from the same light source will become weaker the deeper it is embedded in tissue, and strongly depends on the optical properties of the surrounding tissue. Derivation of quantitative information, therefore, requires tomographic techniques such as fluorescence molecular tomography (FMT), which maps the three-dimensional distribution of a fluorescent probe or protein concentration. The combination of FMT with a structural imaging method such as X-ray computed tomography (CT) or Magnetic Resonance Imaging (MRI) will allow mapping molecular information on a high definition anatomical reference and enable the use of prior information on tissue's optical properties to enhance both resolution and sensitivity. Today many of the fluorescent assays originally developed for studies in cellular systems have been successfully translated for experimental studies in animals. The opportunity of monitoring molecular processes non-invasively in the intact organism is highly attractive from a diagnostic point of view but even more so for the drug developer, who can use the techniques for proof-of-mechanism and proof-of-efficacy studies. This review shall elucidate the current status and potential of fluorescence tomography including recent advances in multimodality imaging approaches for preclinical and clinical drug development. PMID:24310495
2013-01-01
Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243
Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R
2013-06-10
Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.
Deng, S; Zhou, Z; de Hoog, G S; Wang, X; Abliz, P; Sun, J; Najafzadeh, M J; Pan, W; Lei, W; Zhu, S; Hasimu, H; Zhang, P; Guo, Y; Deng, D; Liao, W
2015-12-01
Tinea capitis is very common in Western China, with the most widespread aetiological agent being Trichophyton violaceum, while Microsporum canis is prevalent in the remainder of China. Conventional diagnostics and internal transcribed spacer (ITS) sequencing analyses have proven relatively limited due to the close phylogenetic relationship of anthropophilic dermatophytes. Therefore, alternative molecular tools with sufficient specificity, reproducibility and sensitivity are necessary. To evaluate two molecular techniques [multiplex ligation-dependent probe amplification (MLPA) and rolling circle amplification (RCA)] for rapid detection of the aetiological agents of tinea capitis, T. violaceum and M. canis. Probes of RCA and MLPA were designed with target sequences in the rDNA ITS gene region. Strains tested consist of 31 T. violaceum, 22 M. canis and 24 reference strains of species that are taxonomically close to the target species. The specificity and reproducibility of RCA and MLPA in detection of T. violaceum and M. canis were both 100% in both species. Sensitivity testing showed that RCA was positive at concentrations down to 1·68 × 10(6) copies of DNA in the TvioRCA probe, and 2·7 × 10(8) copies of DNA in McRCA. MLPA yielded positive results at concentrations of DNA down to 1·68 × 10(1) copies in the TvioMLPA probe and 2·7 × 10(2) in McMLPA. The two techniques were sufficiently specific and sensitive for discriminating the target DNA of T. violaceum and M. canis from that of closely related dermatophytes. RCA and MLPA are advantageous in their reliability and ease of operation compared with standard polymerase chain reaction and conventional methods. © 2015 British Association of Dermatologists.
van Ruymbeke, E; Lee, H; Chang, T; Nikopoulou, A; Hadjichristidis, N; Snijkers, F; Vlassopoulos, D
2014-07-21
An emerging challenge in polymer physics is the quantitative understanding of the influence of a macromolecular architecture (i.e., branching) on the rheological response of entangled complex polymers. Recent investigations of the rheology of well-defined architecturally complex polymers have determined the composition in the molecular structure and identified the role of side-products in the measured samples. The combination of different characterization techniques, experimental and/or theoretical, represents the current state-of-the-art. Here we review this interdisciplinary approach to molecular rheology of complex polymers, and show the importance of confronting these different tools for ensuring an accurate characterization of a given polymeric sample. We use statistical tools in order to relate the information available from the synthesis protocols of a sample and its experimental molar mass distribution (typically obtained from size exclusion chromatography), and hence obtain precise information about its structural composition, i.e. enhance the existing sensitivity limit. We critically discuss the use of linear rheology as a reliable quantitative characterization tool, along with the recently developed temperature gradient interaction chromatography. The latter, which has emerged as an indispensable characterization tool for branched architectures, offers unprecedented sensitivity in detecting the presence of different molecular structures in a sample. Combining these techniques is imperative in order to quantify the molecular composition of a polymer and its consequences on the macroscopic properties. We validate this approach by means of a new model asymmetric comb polymer which was synthesized anionically. It was thoroughly characterized and its rheology was carefully analyzed. The main result is that the rheological signal reveals fine molecular details, which must be taken into account to fully elucidate the viscoelastic response of entangled branched polymers. It is important to appreciate that, even optimal model systems, i.e., those synthesized with high-vacuum anionic methods, need thorough characterization via a combination of techniques. Besides helping to improve synthetic techniques, this methodology will be significant in fine-tuning mesoscopic tube-based models and addressing outstanding issues such as the quantitative description of the constraint release mechanism.
Mishra, Amaresh; Fischer, Markus K R; Bäuerle, Peter
2009-01-01
Dye-sensitized solar cells (DSSC) have attracted considerable attention in recent years as they offer the possibility of low-cost conversion of photovoltaic energy. This Review focuses on recent advances in molecular design and technological aspects of metal-free organic dyes for applications in dye-sensitized solar cells. Special attention has been paid to the design principles of these dyes and on the effect of various electrolyte systems. Cosensitization, an emerging technique to extend the absorption range, is also discussed as a way to improve the performance of the device. In addition, we report on inverted dyes for photocathodes, which constitutes a relatively new approach for the production of tandem cells. Special consideration has been paid to the correlation between the molecular structure and physical properties to their performance in DSSCs.
Detection of electrically neutral and nonpolar molecules in ionic solutions using silicon nanowires
NASA Astrophysics Data System (ADS)
Wu, Ying-Pin; Chu, Chia-Jung; Tsai, Li-Chu; Su, Ya-Wen; Chen, Pei-Hua; Moodley, Mathew K.; Huang, Ding; Chen, Yit-Tsong; Yang, Ying-Jay; Chen, Chii-Dong
2017-04-01
We report on a technique that can extend the use of nanowire sensors to the detection of interactions involving nonpolar and neutral molecules in an ionic solution environment. This technique makes use of the fact that molecular interactions result in a change in the permittivity of the molecules involved. For the interactions taking place at the surface of nanowires, this permittivity change can be determined from the analysis of the measured complex impedance of the nanowire. To demonstrate this technique, histidine was detected using different charge polarities controlled by the pH value of the solution. This included the detection of electrically neutral histidine at a sensitivity of 1 pM. Furthermore, it is shown that nonpolar molecules, such as hexane, can also be detected. The technique is applicable to the use of nanowires with and without a surface-insulating oxide. We show that information about the changes in amplitude and the phase of the complex impedance reveals the fundamental characteristics of the molecular interactions, including the molecular field and the permittivity.
Drug sensitivity testing platforms for gastric cancer diagnostics.
Lau, Vianne; Wong, Andrea Li-Ann; Ng, Christopher; Mok, Yingting; Lakshmanan, Manikandan; Yan, Benedict
2016-02-01
Gastric cancer diagnostics has traditionally been histomorphological and primarily the domain of surgical pathologists. Although there is an increasing usage of molecular and genomic techniques for clinical diagnostics, there is an emerging field of personalised drug sensitivity testing. In this review, we describe the various personalised drug sensitivity testing platforms and discuss the challenges facing clinical adoption of these assays for gastric cancer. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
3D metamaterial absorber for attomole molecular detection (Conference Presentation)
NASA Astrophysics Data System (ADS)
Tanaka, Takuo; Ishikawa, Atsushi
2016-09-01
3D Metamaterial absorber was used for a background-suppressed surface-enhanced molecular detection technique. By utilizing the resonant coupling of plasmonic modes of a metamaterial absorber and infrared (IR) vibrational modes of a self-assembled monolayer (SAM), attomole level molecular sensitivity was experimentally demonstrated. IR absorption spectroscopy of molecular vibrations is of importance in chemical, material, medical science and so on, since it provides essential information of the molecular structure, composition, and orientation. In the vibrational spectroscopic techniques, in addition to the weak signals from the molecules, strong background degrades the signal-to-noise ratio, and suppression of the background is crucial for the further improvement of the sensitivity. Here, we demonstrate low-background resonant Surface enhanced IR absorption (SEIRA) by using the metamaterial IR absorber that offers significant background suppression as well as plasmonic enhancement. The fabricated metamaterial consisted of 1D array of Au micro-ribbons on a thick Au film separated by a transparent gap layer made of MgF2. The surface structures were designed to exhibit an anomalous IR absorption at 3000 cm-1, which spectrally overlapped with C-H stretching vibrational modes. 16-Mercaptohexadecanoic acid (16-MHDA) was used as a test molecule, which formed a 2-nm thick SAM with their thiol head-group chemisorbed on the Au surface. In the FTIR measurements, the symmetric and asymmetric C-H stretching modes were clearly observed as reflection peaks within a broad plasmonic absorption of the metamaterial.
Lidar Measurements of Tropospheric Wind Profiles with the Double Edge Technique
NASA Technical Reports Server (NTRS)
Gentry, Bruce M.; Li, Steven X.; Korb, C. Laurence; Mathur, Savyasachee; Chen, Huailin
1998-01-01
Research has established the importance of global tropospheric wind measurements for large scale improvements in numerical weather prediction. In addition, global wind measurements provide data that are fundamental to the understanding and prediction of global climate change. These tasks are closely linked with the goals of the NASA Earth Science Enterprise and Global Climate Change programs. NASA Goddard has been actively involved in the development of direct detection Doppler lidar methods and technologies to meet the wind observing needs of the atmospheric science community. A variety of direct detection Doppler wind lidar measurements have recently been reported indicating the growing interest in this area. Our program at Goddard has concentrated on the development of the edge technique for lidar wind measurements. Implementations of the edge technique using either the aerosol or molecular backscatter for the Doppler wind measurement have been described. The basic principles have been verified in lab and atmospheric lidar wind experiments. The lidar measurements were obtained with an aerosol edge technique lidar operating at 1064 nm. These measurements demonstrated high spatial resolution (22 m) and high velocity sensitivity (rms variances of 0.1 m/s) in the planetary boundary layer (PBL). The aerosol backscatter is typically high in the PBL and the effects of the molecular backscatter can often be neglected. However, as was discussed in the original edge technique paper, the molecular contribution to the signal is significant above the boundary layer and a correction for the effects of molecular backscatter is required to make wind measurements. In addition, the molecular signal is a dominant source of noise in regions where the molecular to aerosol ratio is large since the energy monitor channel used in the single edge technique measures the sum of the aerosol and molecular signals. To extend the operation of the edge technique into the free troposphere we have developed a variation of the edge technique called the double edge technique. In this paper a ground based aerosol double edge lidar is described and the first measurements of wind profiles in the free troposphere obtained with this lidar will be presented.
Smart dual-mode fluorescent gold nanoparticle agents.
Kang, Kyung A; Wang, Jianting
2014-01-01
Fluorophore-mediated, molecular sensing is one of the most popular and important technique in biomedical studies. As in any sensing technique, the two most important factors in this sensing are the sensitivity and specificity. Since the fluorescence of a fluorophore is emitted in the process of fluorophore electrons returning from their excited to ground state, a tool that can locally manipulate the electron state can be useful to maximize the sensitivity and specificity. A good tool candidate for this purpose is nanosized metal particles that can form an electromagnetic (EM) field at a sufficiently strong level, upon receiving a particular wavelength that fits the excitation wavelength of the fluorophore to be used. There are several metal nanoparticle types that can generate a sufficiently strong EM field for this purpose. Nevertheless, for the biomedical studies, which require minimal toxicity, gold nanoparticles (GNPs) are known to be the most suitable. In this article, various methods for fluorescence alteration using GNPs, which can be beneficially utilized for biomarker-specific, highly sensitive molecular sensing and imaging, are discussed. For further resources related to this article, please visit the WIREs website. The authors have declared no conflicts of interest for this article. © 2014 Wiley Periodicals, Inc.
Practical Molecular Biology for Students: An Integrated Approach to Teaching Basic Techniques.
ERIC Educational Resources Information Center
Hames, B. David; And Others
1990-01-01
An activity that introduces students to the correct handling of bacterial recombinants, antibiotic sensitivity testing, insertional inactivation, plasmid DNA isolation, restriction endonuclease digestion, agarose gel electrophoresis, Southern blotting, hybridization, and autoradiography is presented. A list of needed materials, procedures, safety…
Ohmido, Nobuko; Fukui, Kiichi; Kinoshita, Toshiro
2010-01-01
Fluorescence in situ hybridization (FISH) is an effective method for the physical mapping of genes and repetitive DNA sequences on chromosomes. Physical mapping of unique nucleotide sequences on specific rice chromosome regions was performed using a combination of chromosome identification and highly sensitive FISH. Increases in the detection sensitivity of smaller DNA sequences and improvements in spatial resolution have ushered in a new phase in FISH technology. Thus, it is now possible to perform in situ hybridization on somatic chromosomes, pachytene chromosomes, and even on extended DNA fibers (EDFs). Pachytene-FISH allows the integration of genetic linkage maps and quantitative chromosome maps. Visualization methods using FISH can reveal the spatial organization of the centromere, heterochromatin/euchromatin, and the terminal structures of rice chromosomes. Furthermore, EDF-FISH and the DNA combing technique can resolve a spatial distance of 1 kb between adjacent DNA sequences, and the detection of even a 300-bp target is now feasible. The copy numbers of various repetitive sequences and the sizes of various DNA molecules were quantitatively measured using the molecular combing technique. This review describes the significance of these advances in molecular cytology in rice and discusses future applications in plant studies using visualization techniques.
Sanjuan-Jimenez, Rocio; Colmenero, Juan D; Morata, Pilar
2017-06-01
Brucellosis remains an emerging and re-emerging zoonosis worldwide causing high human morbidity. It usually affects persons who are permanently exposed to fastidious microorganisms of the Brucella genus and has a nonspecific clinical picture. Thus, diagnosis of brucellosis can sometimes be difficult. Molecular techniques have recently been found very useful in the diagnosis of brucellosis together with its common and very diverse focal complications. We herein review all the lessons learned by our group concerning the molecular diagnosis of human brucellosis over the last twenty years. The results, initially using one-step conventional PCR, later PCR-ELISA and more recently real-time PCR, using both fluorescent intercalating reagents (SYBR-Green I) and specific probes (Taqman), have shown that these techniques are all much more sensitive than bacteriological methods and more specific than the usual serological techniques for the diagnosis of primary infection, the post-treatment control of the disease, early detection of relapse and the diagnosis of focal complications. Optimization of the technique and improvements introduced over the years show that molecular methods, currently accessible for most clinical laboratories, enable easy rapid diagnosis of brucellosis at the same time as they avoid any risk to laboratory personnel while handling live Brucella spp. Copyright © 2017 Elsevier B.V. All rights reserved.
Plasmonic SERS nanochips and nanoprobes for medical diagnostics and bio-energy applications
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Wang, Hsin-Neng; Crawford, Bridget M.; Fales, Andrew M.; Vo-Dinh, Tuan
2017-02-01
The development of rapid, easy-to-use, cost-effective, high accuracy, and high sensitive DNA detection methods for molecular diagnostics has been receiving increasing interest. Over the last five years, our laboratory has developed several chip-based DNA detection techniques including the molecular sentinel-on-chip (MSC), the multiplex MSC, and the inverse molecular sentinel-on-chip (iMS-on-Chip). In these techniques, plasmonic surface-enhanced Raman scattering (SERS) Nanowave chips were functionalized with DNA probes for single-step DNA detection. Sensing mechanisms were based on hybridization of target sequences and DNA probes, resulting in a distance change between SERS reporters and the Nanowave chip's gold surface. This distance change resulted in change in SERS intensity, thus indicating the presence and capture of the target sequences. Our techniques were single-step DNA detection techniques. Target sequences were detected by simple delivery of sample solutions onto DNA probe-functionalized Nanowave chips and SERS signals were measured after 1h - 2h incubation. Target sequence labeling or washing to remove unreacted components was not required, making the techniques simple, easy-to-use, and cost effective. The usefulness of the techniques for medical diagnostics was illustrated by the detection of genetic biomarkers for respiratory viral infection and of dengue virus 4 DNA.
Recent technological advancements in tuberculosis diagnostics - A review.
Gupta, Shagun; Kakkar, Vipan
2018-09-15
Early diagnosis and on-time effective treatment are indispensable for Tuberculosis (TB) control - a life threatening infectious communicable disease. The conventional techniques for diagnosing TB normally take two to three weeks. This delay in diagnosis and further increase in detection complexity due to the emerging risks of XDR-TB (Extensively drug Resistant-TB) and MDR-TB (Multidrug Resistant-TB) are evoking interest of researchers in the field of developing rapid TB detection techniques such as biosensing and other point-of-care (POC) techniques. Biosensing technologies along with the collaboration with nanotechnology have enormous potential to boost the MTB detection and for overall management in clinical diagnosis. A diverse range of portable, sensitive and rapid biosensors based on different signal transducer principles and with different biomarkers detection capabilities have been developed for TB detection in the early stages. Further, a lot of progress has been achieved over the years in developing various point-of-care diagnostic tools including non-molecular methods and molecular techniques. The objective of this study is to present a succinct review of the available TB detection techniques that are either in use or under development. The focus of this review is on the current developments occurred in nano-biosensing technologies. A synopsis of ameliorations in different non-molecular diagnostic tools and progress in the field of molecular techniques along with the role of emerging Lab-on-Chip technology for diagnosing and mitigating the TB consequences have also been presented. Copyright © 2018 Elsevier B.V. All rights reserved.
Immobilized enzymes: understanding enzyme - surface interactions at the molecular level.
Hoarau, Marie; Badieyan, Somayesadat; Marsh, E Neil G
2017-11-22
Enzymes immobilized on solid supports have important and industrial and medical applications. However, their uses are limited by the significant reductions in activity and stability that often accompany the immobilization process. Here we review recent advances in our understanding of the molecular level interactions between proteins and supporting surfaces that contribute to changes in stability and activity. This understanding has been facilitated by the application of various surface-sensitive spectroscopic techniques that allow the structure and orientation of enzymes at the solid/liquid interface to be probed, often with monolayer sensitivity. An appreciation of the molecular interactions between enzyme and surface support has allowed the surface chemistry and method of enzyme attachement to be fine-tuned such that activity and stability can be greatly enhanced. These advances suggest that a much wider variety of enzymes may eventually be amenable to immobilization as green catalysts.
NASA Technical Reports Server (NTRS)
Nicholson, Lee M.; Whitley, Karen S.; Gates, Thomas S.
2000-01-01
The effect of molecular weight on the viscoelastic performance of an advanced polymer (LaRC-SI) was investigated through the use of creep compliance tests. Testing consisted of short-term isothermal creep and recovery with the creep segments performed under constant load. The tests were conducted at three temperatures below the glass transition temperature of five materials of different molecular weight. Through the use of time-aging-time superposition procedures, the material constants, material master curves and aging-related parameters were evaluated at each temperature for a given molecular weight. The time-temperature superposition technique helped to describe the effect of temperature on the timescale of the viscoelastic response of each molecular weight. It was shown that the low molecular weight materials have higher creep compliance and creep rate, and are more sensitive to temperature than the high molecular weight materials. Furthermore, a critical molecular weight transition was observed to occur at a weight-average molecular weight of M (bar) (sub w) 25000 g/mol below which, the temperature sensitivity of the time-temperature superposition shift factor increases rapidly. The short-term creep compliance data were used in association with Struik's effective time theory to predict the long-term creep compliance behavior for the different molecular weights. At long timescales, physical aging serves to significantly decrease the creep compliance and creep rate of all the materials tested.
Molecular diagnostics for human leptospirosis.
Waggoner, Jesse J; Pinsky, Benjamin A
2016-10-01
The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.
Critical layer thickness in In/sub 0. 2/Ga/sub 0. 8/As/GaAs single strained quantum well structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, I.J.; Gourley, P.L.; Dawson, L.R.
1987-09-28
We report accurate determination of the critical layer thickness (CLT) for single strained-layer epitaxy in the InGaAs/GaAs system. Our samples were molecular beam epitaxially grown, selectively doped, single quantum well structures comprising a strained In/sub 0.2/Ga/sub 0.8/As layer imbedded in GaAs. We determined the CLT by two sensitive techniques: Hall-effect measurements at 77 K and photoluminescence microscopy. Both techniques indicate a CLT of about 20 nm. This value is close to that determined previously (--15 nm) for comparable strained-layer superlattices, but considerably less than the value of --45 nm suggested by recent x-ray rocking-curve measurements. We show by a simplemore » calculation that photoluminescence microscopy is more than two orders of magnitude more sensitive to dislocations than x-ray diffraction. Our results re-emphasize the necessity of using high-sensitivity techniques for accurate determination of critical layer thicknesses.« less
Nonlinear Interferometric Vibrational Imaging (NIVI) with Novel Optical Sources
NASA Astrophysics Data System (ADS)
Boppart, Stephen A.; King, Matthew D.; Liu, Yuan; Tu, Haohua; Gruebele, Martin
Optical imaging is essential in medicine and in fundamental studies of biological systems. Although many existing imaging modalities can supply valuable information, not all are capable of label-free imaging with high-contrast and molecular specificity. The application of molecular or nanoparticle contrast agents may adversely influence the biological system under investigation. These substances also present ongoing concerns over toxicity or particle clearance, which must be properly addressed before their approval for in vivo human imaging. Hence there is an increasing appreciation for label-free imaging techniques. It is of primary importance to develop imaging techniques that can indiscriminately identify and quantify biochemical compositions to high degrees of sensitivity and specificity through only the intrinsic optical response of endogenous molecular species. The development and use of nonlinear interferometric vibrational imaging, which is based on the interferometric detection of optical signals from coherent anti-Stokes Raman scattering (CARS), along with novel optical sources, offers the potential for label-free molecular imaging.
Chaudhary, Prem Prashant; Brablcová, Lenka; Buriánková, Iva; Rulík, Martin
2013-09-01
Methanogenic archaeal communities existing in freshwater sediments are responsible for approximately 50 % of the total global emission of methane. This process contributes significantly to global warming and, hence, necessitates interventional control measures to limit its emission. Unfortunately, the diversity and functional interactions of methanogenic populations occurring in these habitats are yet to be fully characterized. Considering several disadvantages of conventional culture-based methodologies, in recent years, impetus is given to molecular biology approaches to determine the community structure of freshwater sedimentary methanogenic archaea. 16S rRNA and methyl coenzyme M reductase (mcrA) gene-based cloning techniques are the first choice for this purpose. In addition, electrophoresis-based (denaturing gradient gel electrophoresis, temperature gradient gel electrophoresis, and terminal restriction fragment length polymorphism) and quantitative real-time polymerase chain reaction techniques have also found extensive applications. These techniques are highly sensitive, rapid, and reliable as compared to traditional culture-dependent approaches. Molecular diversity studies revealed the dominance of the orders Methanomicrobiales and Methanosarcinales of methanogens in freshwater sediments. The present review discusses in detail the status of the diversity of methanogens and the molecular approaches applied in this area of research.
Veterinary extension on sampling techniques related to heartwater research.
Steyn, H C; McCrindle, C M E; Du Toit, D
2010-09-01
Heartwater, a tick-borne disease caused by Ehrlichia ruminantium, is considered to be a significant cause of mortality amongst domestic and wild ruminants in South Africa. The main vector is Amblyomma hebraeum and although previous epidemiological studies have outlined endemic areas based on mortalities, these have been limited by diagnostic methods which relied mainly on positive brain smears. The indirect fluorescent antibody test (IFA) has a low specificity for heartwater organisms as it cross-reacts with some other species. Since the advent of biotechnology and genomics, molecular epidemiology has evolved using the methodology of traditional epidemiology coupled with the new molecular techniques. A new quantitative real-time polymerase chain reaction (qPCR) test has been developed for rapid and accurate diagnosis of heartwater in the live animal. This method can also be used to survey populations of A. hebraeum ticks for heartwater. Sampling whole blood and ticks for this qPCR differs from routine serum sampling, which is used for many serological tests. Veterinary field staff, particularly animal health technicians, are involved in surveillance and monitoring of controlled and other diseases of animals in South Africa. However, it was found that the sampling of whole blood was not done correctly, probably because it is a new sampling technique specific for new technology, where the heartwater organism is much more labile than the serum antibodies required for other tests. This qPCR technique is highly sensitive and can diagnose heartwater in the living animal within 2 hours, in time to treat it. Poor sampling techniques that decrease the sensitivity of the test will, however, result in a false negative diagnosis. This paper describes the development of a skills training programme for para-veterinary field staff, to facilitate research into the molecular epidemiology of heartwater in ruminants and eliminate any sampling bias due to collection errors. Humane handling techniques were also included in the training, in line with the current focus on improved livestock welfare.
Diagnostic Molecular Microbiology: A 2018 Snapshot.
Fairfax, Marilynn Ransom; Bluth, Martin H; Salimnia, Hossein
2018-06-01
Molecular biological techniques have evolved expeditiously and in turn have been applied to the detection of infectious disease. Maturation of these technologies and their coupling with related technological advancement in fluorescence, electronics, digitization, nanodynamics, and sensors among others have afforded clinical medicine additional tools toward expedient identification of infectious organisms at concentrations and sensitivities previously unattainable. These advancements have been adapted in select settings toward addressing clinical demands for more timely and effective patient management. Copyright © 2018 Elsevier Inc. All rights reserved.
Ahmed, Heba A; MacLeod, Ewan T; Hide, Geoff; Welburn, Susan C; Picozzi, Kim
2011-05-07
Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach.
Centelleghe, Cinzia; Beffagna, Giorgia; Zanetti, Rossella; Zappulli, Valentina; Di Guardo, Giovanni; Mazzariol, Sandro
2016-09-01
Cetacean Morbillivirus (CeMV) has been identified as the most pathogenic virus for cetaceans. Over the past three decades, this RNA virus has caused several outbreaks of lethal disease in odontocetes and mysticetes worldwide. Isolation and identification of CeMV RNA is very challenging in whales because of the poor preservation status frequently shown by tissues from stranded animals. Nested reverse transcription polymerase chain reaction (nested RT-PCR) is used instead of conventional RT-PCR when it is necessary to increase the sensitivity and the specificity of the reaction. This study describes a new nested RT-PCR technique useful to amplify small amounts of the cDNA copy of Cetacean morbillivirus (CeMV) when it is present in scant quantity in whales' biological specimens. This technique was used to analyze different tissues (lung, brain, spleen and other lymphoid tissues) from one under human care seal and seven cetaceans stranded along the Italian coastline between October 2011 and September 2015. A well-characterized, 200 base pair (bp) fragment of the dolphin Morbillivirus (DMV) haemagglutinin (H) gene, obtained by nested RT-PCR, was sequenced and used to confirm DMV positivity in all the eight marine mammals under study. In conclusion, this nested RT-PCR protocol can represent a sensitive detection method to identify CeMV-positive, poorly preserved tissue samples. Furthermore, this is also a rather inexpensive molecular technique, relatively easy to apply. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jeongho; Kim, Kyung Hwan; Oang, Key Young
Characterization of transient molecular structures formed during chemical and biological processes is essential for understanding their mechanisms and functions. Over the last decade, time-resolved X-ray liquidography (TRXL) and time-resolved X-ray absorption spectroscopy (TRXAS) have emerged as powerful techniques for molecular and electronic structural analysis of photoinduced reactions in the solution phase. Both techniques make use of a pump–probe scheme that consists of (1) an optical pump pulse to initiate a photoinduced process and (2) an X-ray probe pulse to monitor changes in the molecular structure as a function of time delay between pump and probe pulses. TRXL is sensitive tomore » changes in the global molecular structure and therefore can be used to elucidate structural changes of reacting solute molecules as well as the collective response of solvent molecules. On the other hand, TRXAS can be used to probe changes in both local geometrical and electronic structures of specific X-ray-absorbing atoms due to the element-specific nature of core-level transitions. These techniques are complementary to each other and a combination of the two methods will enhance the capability of accurately obtaining structural changes induced by photoexcitation. Here we review the principles of TRXL and TRXAS and present recent application examples of the two methods for studying chemical and biological processes in solution. Furthermore, we briefly discuss the prospect of using X-ray free electron lasers for the two techniques, which will allow us to keep track of structural dynamics on femtosecond time scales in various solution-phase molecular reactions.« less
Guevara, María Ángeles; de María, Nuria; Sáez-Laguna, Enrique; Vélez, María Dolores; Cervera, María Teresa; Cabezas, José Antonio
2017-01-01
Different molecular techniques have been developed to study either the global level of methylated cytosines or methylation at specific gene sequences. One of them is the methylation-sensitive amplified polymorphism technique (MSAP) which is a modification of amplified fragment length polymorphism (AFLP). It has been used to study methylation of anonymous CCGG sequences in different fungi, plants, and animal species. The main variation of this technique resides on the use of isoschizomers with different methylation sensitivity (such as HpaII and MspI) as a frequent-cutter restriction enzyme. For each sample, MSAP analysis is performed using both EcoRI/HpaII- and EcoRI/MspI-digested samples. A comparative analysis between EcoRI/HpaII and EcoRI/MspI fragment patterns allows the identification of two types of polymorphisms: (1) methylation-insensitive polymorphisms that show common EcoRI/HpaII and EcoRI/MspI patterns but are detected as polymorphic amplified fragments among samples and (2) methylation-sensitive polymorphisms which are associated with the amplified fragments that differ in their presence or absence or in their intensity between EcoRI/HpaII and EcoRI/MspI patterns. This chapter describes a detailed protocol of this technique and discusses the modifications that can be applied to adjust the technology to different species of interest.
Phase 2 SBIR Final Report: An Ultra-Sensitive Optical Biosensor for Flood Safety
2002-08-23
can be completed in 2 to 4 hours. Currently accepted tests using commercial test kits based on immunochemical techniques offer results in 22 to 24...tagging is imperfect, leading to a background of non-specific surface and molecular binding limiting the signal. The use of a reporter fluorochrome can ...Waveguide Patterning: Surface flow channels: The rectangular cuvettes (as shown in Section II, Figure 4-3) can be etched using standard techniques. The
Optical Brain Imaging: A Powerful Tool for Neuroscience.
Zhu, Xinpei; Xia, Yanfang; Wang, Xuecen; Si, Ke; Gong, Wei
2017-02-01
As the control center of organisms, the brain remains little understood due to its complexity. Taking advantage of imaging methods, scientists have found an accessible approach to unraveling the mystery of neuroscience. Among these methods, optical imaging techniques are widely used due to their high molecular specificity and single-molecule sensitivity. Here, we overview several optical imaging techniques in neuroscience of recent years, including brain clearing, the micro-optical sectioning tomography system, and deep tissue imaging.
NASA Astrophysics Data System (ADS)
Es-Safi, Nour-Eddine; Essassi, El Mokhtar; Massoui, Mohamed; Banoub, Joseph
Mass spectrometry is an important tool for the identification and structural elucidation of natural and synthesized compounds. Its high sensitivity and the possibility of coupling liquid chromatography with mass spectrometry detection make it a technique of choice for the investigation of complex mixtures like raw natural extracts. The mass spectrometer is a universal detector that can achieve very high sensitivity and provide information on the molecular mass. More detailed information can be subsequently obtained by resorting to collision-induced dissociation tandem mass spectrometry (CID-MS/MS). In this review, the application of mass spectrometric techniques for the identification of natural and synthetic compounds is presented. The gas-phase fragmentation patterns of a series of four natural flavonoid glycosides, three synthesized benzodiazepines and two synthesized quinoxalinone derivatives were investigated using electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry techniques. Exact accurate masses were measured using a modorate resolution quadrupole orthogonal time-of-flight QqTOF-MS/MS hybrid mass spectrometer instrument. Confirmation of the molecular masses and the chemical structures of the studied compounds were achieved by exploring the gas-phase breakdown routes of the ionized molecules. This was rationalized by conducting low-energy collision CID-MS/MS analyses (product ion- and precursor ion scans) using a conventional quadrupole hexapole-quadrupole (QhQ) tandem mass spectrometer.
Hyperspectral imaging with laser-scanning sum-frequency generation microscopy
Hanninen, Adam; Shu, Ming Wai; Potma, Eric O.
2017-01-01
Vibrationally sensitive sum-frequency generation (SFG) microscopy is a chemically selective imaging technique sensitive to non-centrosymmetric molecular arrangements in biological samples. The routine use of SFG microscopy has been hampered by the difficulty of integrating the required mid-infrared excitation light into a conventional, laser-scanning nonlinear optical (NLO) microscope. In this work, we describe minor modifications to a regular laser-scanning microscope to accommodate SFG microscopy as an imaging modality. We achieve vibrationally sensitive SFG imaging of biological samples with sub-μm resolution at image acquisition rates of 1 frame/s, almost two orders of magnitude faster than attained with previous point-scanning SFG microscopes. Using the fast scanning capability, we demonstrate hyperspectral SFG imaging in the CH-stretching vibrational range and point out its use in the study of molecular orientation and arrangement in biologically relevant samples. We also show multimodal imaging by combining SFG microscopy with second-harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) on the same imaging platfrom. This development underlines that SFG microscopy is a unique modality with a spatial resolution and image acquisition time comparable to that of other NLO imaging techniques, making point-scanning SFG microscopy a valuable member of the NLO imaging family. PMID:28966861
NASA Astrophysics Data System (ADS)
Yano, Taka-aki; Hara, Masahiko
2018-06-01
Tip-enhanced Raman scattering microscopy, a family of scanning probe microscopy techniques, has been recognized as a powerful surface analytical technique with both single-molecule sensitivity and angstrom-scale spatial resolution. This review covers the current status of tip-enhanced Raman scattering microscopy in surface and material nanosciences, including a brief history, the basic principles, and applications for the nanoscale characterization of a variety of nanomaterials. The focus is on the recent trend of combining tip-enhanced Raman scattering microscopy with various external stimuli such as pressure, voltage, light, and temperature, which enables the local control of the molecular properties and functions and also enables chemical reactions to be induced on a nanometer scale.
THz QCL-Based Cryogen-Free Spectrometer for in Situ Trace Gas Sensing
Consolino, Luigi; Bartalini, Saverio; Beere, Harvey E.; Ritchie, David A.; Vitiello, Miriam Serena; De Natale, Paolo
2013-01-01
We report on a set of high-sensitivity terahertz spectroscopy experiments making use of QCLs to detect rotational molecular transitions in the far-infrared. We demonstrate that using a compact and transportable cryogen-free setup, based on a quantum cascade laser in a closed-cycle Stirling cryostat, and pyroelectric detectors, a considerable improvement in sensitivity can be obtained by implementing a wavelength modulation spectroscopy technique. Indeed, we show that the sensitivity of methanol vapour detection can be improved by a factor ≈ 4 with respect to standard direct absorption approaches, offering perspectives for high sensitivity detection of a number of chemical compounds across the far-infrared spectral range. PMID:23478601
THz QCL-based cryogen-free spectrometer for in situ trace gas sensing.
Consolino, Luigi; Bartalini, Saverio; Beere, Harvey E; Ritchie, David A; Vitiello, Miriam Serena; De Natale, Paolo
2013-03-11
We report on a set of high-sensitivity terahertz spectroscopy experiments making use of QCLs to detect rotational molecular transitions in the far-infrared. We demonstrate that using a compact and transportable cryogen-free setup, based on a quantum cascade laser in a closed-cycle Stirling cryostat, and pyroelectric detectors, a considerable improvement in sensitivity can be obtained by implementing a wavelength modulation spectroscopy technique. Indeed, we show that the sensitivity of methanol vapour detection can be improved by a factor ≈ 4 with respect to standard direct absorption approaches, offering perspectives for high sensitivity detection of a number of chemical compounds across the far-infrared spectral range.
Application of cytology and molecular biology in diagnosing premalignant or malignant oral lesions
Mehrotra, Ravi; Gupta, Anurag; Singh, Mamta; Ibrahim, Rahela
2006-01-01
Early detection of a premalignant or cancerous oral lesion promises to improve the survival and the morbidity of patients suffering from these conditions. Cytological study of oral cells is a non-aggressive technique that is well accepted by the patient, and is therefore an attractive option for the early diagnosis of oral cancer, including epithelial atypia and squamous cell carcinoma. However its usage has been limited so far due to poor sensitivity and specificity in diagnosing oral malignancies. Lately it has re-emerged due to improved methods and it's application in oral precancer and cancer as a diagnostic and predictive method as well as for monitoring patients. Newer diagnostic techniques such as "brush biopsy" and molecular studies have been developed. Recent advances in cytological techniques and novel aspects of applications of scraped or exfoliative cytology for detecting these lesions and predicting their progression or recurrence are reviewed here. PMID:16556320
Advances in Small Animal Imaging Systems
NASA Astrophysics Data System (ADS)
Loudos, George K.
2007-11-01
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided.
Biance-Valero, E; De Laval, F; Delerue, M; Savini, H; Cheinin, S; Leroy, P; Soullié, B
2013-05-01
The authors report the results of molecular biology techniques for the early diagnosis of cases (invasion phase) of schistosomiasis during two epidemics occurring during French military projects in the Central African Republic and Madagascar. The use of these techniques in real time for subjects not residing in the endemic area significantly improves the sensitivity of screening. The attack rates of these episodes, according to a case definition that took positive specific PCR results into account, were 59% and 26%. These results are a concrete illustration of the proverb that "yaws begin where the trail stops".
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC),more » supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.« less
Jafari, M T; Rezaei, B; Zaker, B
2009-05-01
Application of ion mobility spectrometry (IMS) as the detection technique for a separation method based on molecular imprinted polymer (MIP) was investigated and evaluated for the first time. On the basis of the results obtained in this work, the MIP-IMS system can be used as a powerful technique for separation, preconcentration, and detection of the metronidazole drug in pharmaceutical and human serum samples. The method is exhaustively validated in terms of sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.05-70.00 microg/mL was obtained for the determination of metronidazole with IMS. The recovery of analyzed drug was calculated to be above 89%, and the relative standard deviation (RSD) was lower than 6% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient cleanup of the samples using MIP separation before the analysis by IMS as a detection technique.
White, P. Lewis; Archer, Alice E.; Barnes, Rosemary A.
2005-01-01
The accepted limitations associated with classic culture techniques for the diagnosis of invasive fungal infections have lead to the emergence of many non-culture-based methods. With superior sensitivities and quicker turnaround times, non-culture-based methods may aid the diagnosis of invasive fungal infections. In this review of the diagnostic service, we assessed the performances of two antigen detection techniques (enzyme-linked immunosorbent assay [ELISA] and latex agglutination) with a molecular method for the detection of invasive Candida infection and invasive aspergillosis. The specificities for all three assays were high (≥97%), although the Candida PCR method had enhanced sensitivity over both ELISA and latex agglutination with values of 95%, 75%, and 25%, respectively. However, calculating significant sensitivity values for the Aspergillus detection methods was not feasible due to a low number of proven/probable cases. Despite enhanced sensitivity, the PCR method failed to detect nucleic acid in a probable case of invasive Candida infection that was detected by ELISA. In conclusion, both PCR and ELISA techniques should be used in unison to aid the detection of invasive fungal infections. PMID:15872239
Maas, Miriam; van Roon, Annika; Dam-Deisz, Cecile; Opsteegh, Marieke; Massolo, Alessandro; Deksne, Gunita; Teunis, Peter; van der Giessen, Joke
2016-10-30
A new method, based on a magnetic capture based DNA extraction followed by qPCR, was developed for the detection of the zoonotic parasite Echinococcus multilocularis in definitive hosts. Latent class analysis was used to compare this new method with the currently used phenol-chloroform DNA extraction followed by single tube nested PCR. In total, 60 red foxes and coyotes from three different locations were tested with both molecular methods and the sedimentation and counting technique (SCT) or intestinal scraping technique (IST). Though based on a limited number of samples, it could be established that the magnetic capture based DNA extraction followed by qPCR showed similar sensitivity and specificity as the currently used phenol-chloroform DNA extraction followed by single tube nested PCR. All methods have a high specificity as shown by Bayesian latent class analysis. Both molecular assays have higher sensitivities than the combined SCT and IST, though the uncertainties in sensitivity estimates were wide for all assays tested. The magnetic capture based DNA extraction followed by qPCR has the advantage of not requiring hazardous chemicals like the phenol-chloroform DNA extraction followed by single tube nested PCR. This supports the replacement of the phenol-chloroform DNA extraction followed by single tube nested PCR by the magnetic capture based DNA extraction followed by qPCR for molecular detection of E. multilocularis in definitive hosts. Copyright © 2016 Elsevier B.V. All rights reserved.
Alba Álvarez, Luz María; García García, José María; Pérez Hernández, M Dolores; Martínez González, Susana; Palacios Gutiérrez, Juan José
2017-04-01
To determine the utility of molecular techniques in the diagnosis of resistance and the extent of resistance to first-line drugs in our region. From 2004 to 2013, 1,889 strains of Mycobacterium tuberculosis complex isolated in Asturias, Spain, were studied using phenotypic (Clinical and Laboratory Standards Institute guidelines) and molecular (INNOLiPA RIF-TB © ; GenotypeMDRplus © ; GenotypeMDRsl © ) sensitivity tests. 1,759 strains (94.52%) were sensitive to all first-line drugs, and 102 strains (5.48%) showed some resistance: 81 strains (4.35%) were resistant to 1 single drug, 14 (0.75%) were polyresistant, and 7 (0.37%) were multiresistant (resistant to rifampicin and isoniazid). In total, 137 resistances were identified: 60 to isoniazid (3.22%), 7 to rifampicin (0.37%), 9 to pyrazinamide (0.48%), 11 to ethambutol (0.59%), and 50 to streptomycin (2.68%). Of the mutations detected, 75.9% (63/83) correlated with resistance, while 24.09% of mutations detected (20/83) were not associated with resistance; 16 of these involved a silent mutation at codon 514 of the rpoB gene. Between 0 and 90% of strains, depending on the drug under consideration, were resistant even when no gene mutations were detected using marketed systems. Molecular techniques are very useful, particularly for obtaining rapid results, but these must be confirmed with standard phenotypic sensitivity testing. The rate of resistance in our region is low and multi-drug resistantcases (0.37%) are sporadic. Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.
Molecular wake shield gas analyzer
NASA Technical Reports Server (NTRS)
Hoffman, J. H.
1980-01-01
Techniques for measuring and characterizing the ultrahigh vacuum in the wake of an orbiting spacecraft are studied. A high sensitivity mass spectrometer that contains a double mass analyzer consisting of an open source miniature magnetic sector field neutral gas analyzer and an identical ion analyzer is proposed. These are configured to detect and identify gas and ion species of hydrogen, helium, nitrogen, oxygen, nitric oxide, and carbon dioxide and any other gas or ion species in the 1 to 46 amu mass range. This range covers the normal atmospheric constituents. The sensitivity of the instrument is sufficient to measure ambient gases and ion with a particle density of the order of one per cc. A chemical pump, or getter, is mounted near the entrance aperture of the neutral gas analyzer which integrates the absorption of ambient gases for a selectable period of time for subsequent release and analysis. The sensitivity is realizable for all but rare gases using this technique.
SU-E-I-39: Molecular Image Guided Cancer Stem Cells Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdollahi, H
Purpose: Cancer stem cells resistance to radiation is a problematic issue that has caused a big fail in cancer treatment. Methods: As a primary work, molecular imaging can indicate the main mechanisms of radiation resistance of cancer stem cells. By developing and commissioning new probes and nanomolecules and biomarkers, radiation scientist will able to identify the essential pathways of radiation resistance of cancer stem cells. As the second solution, molecular imaging is a best way to find biological target volume and delineate cancer stem cell tissues. In the other hand, by molecular imaging techniques one can image the treatment responsemore » in tumor and also in normal tissue. In this issue, the response of cancer stem cells to radiation during therapy course can be imaged, also the main mechanisms of radiation resistance and finding the best radiation modifiers (sensitizers) can be achieved by molecular imaging modalities. In adaptive radiotherapy the molecular imaging plays a vital role to have higher tumor control probability by delivering high radiation doses to cancer stem cells in any time of treatment. The outcome of a feasible treatment is dependent to high cancer stem cells response to radiation and removing all of which, so a good imaging modality can show this issue and preventing of tumor recurrence and metastasis. Results: Our results are dependent to use of molecular imaging as a new modality in the clinic. We propose molecular imaging as a new radiobiological technique to solve radiation therapy problems due to cancer stem cells. Conclusion: Molecular imaging guided cancer stem cell diagnosis and therapy is a new approach in the field of cancer treatment. This new radiobiological imaging technique should be developed in all clinics as a feasible tool that is more biological than physical imaging.« less
Elbasuney, Sherif; El-Sherif, Ashraf F
2017-01-01
The instant detection of explosives and explosive-related compounds has become an urgent priority in recent years for homeland security and counter-terrorism applications. Modern techniques should offer enhancement in selectivity, sensitivity, and standoff distances. Miniaturisation, portability, and field-ruggedisation are crucial requirements. This study reports on instant and standoff identification of concealed explosive-related compounds using customized Raman technique. Stokes Raman spectra of common explosive-related compounds were generated and spectrally resolved to create characteristic finger print spectra. The scattered Raman emissions over the band 400:2000cm -1 were compared to infrared absorption using FTIR. It has been demonstrated that the two vibrational spectroscopic techniques were opposite and completing each other. Molecular vibrations with strong absorption in infrared (those involve strong change in dipole moments) induced weak signals in Raman and vice versa. The tailored Raman offered instant detection, high sensitivity, and standoff detection capabilities. Raman demonstrated characteristic fingerprint spectra with stable baseline and sharp intense peaks. Complete correlations of absorption/scattered signals to certain molecular vibrations were conducted to generate an entire spectroscopic profile of explosive-related compounds. This manuscript shades the light on Raman as one of the prevailing technologies for instantaneous detection of explosive-related compounds. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Perricone, Margherita; Palandri, Francesca; Ottaviani, Emanuela; Angelini, Mario; Bagli, Laura; Bellesia, Enrica; Donati, Meris; Gemmati, Donato; Zucchini, Patrizia; Mancini, Stefania; Marchica, Valentina; Trubini, Serena; Matteis, Giovanna De; Zacomo, Silvia Di; Favarato, Mosè; Fioroni, Annamaria; Bolzonella, Caterina; Maccari, Giorgia; Navaglia, Filippo; Gatti, Daniela; Toffolatti, Luisa; Orlandi, Linda; Laloux, Vèronique; Manfrini, Marco; Galieni, Piero; Giannini, Barbara; Tieghi, Alessia; Barulli, Sara; Serino, Maria Luisa; Maccaferri, Monica; Scortechini, Anna Rita; Giuliani, Nicola; Vallisa, Daniele; Bonifacio, Massimiliano; Accorsi, Patrizia; Salbe, Cristina; Fazio, Vinicio; Gusella, Milena; Toffoletti, Eleonora; Salvucci, Marzia; Svaldi, Mirija; Gherlinzoni, Filippo; Cassavia, Francesca; Orsini, Francesco; Martinelli, Giovanni
2017-01-01
To date, a plenty of techniques for the detection of JAK2V617F is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory. A network of 19 centers was established to 1) evaluate the inter- and intra-laboratory variability in JAK2V617F quantification, 2) identify the most robust assay for the standardization of the molecular test and 3) allow consistent interpretation of individual patient analysis results. The study was conceived in 3 different rounds, in which all centers had to blindly test DNA samples with different JAK2V617F allele burden (AB) using both quantitative and qualitative assays. The positivity of samples with an AB < 1% was not detected by qualitative assays. Conversely, laboratories performing the quantitative approach were able to determine the expected JAK2V617F AB. Quantitative results were reliable across all mutation loads with moderate variability at low AB (0.1 and 1%; CV = 0.46 and 0.77, respectively). Remarkably, all laboratories clearly distinguished between the 0.1 and 1% mutated samples. In conclusion, a qualitative approach is not sensitive enough to detect the JAK2V617F mutation, especially at low AB. On the contrary, the ipsogen JAK2 MutaQuant CE-IVD kit resulted in a high, efficient and sensitive quantification detection of all mutation loads. This study sets the basis for the standardization of molecular techniques for JAK2V617F determination, which will require the employment of approved operating procedures and the use of certificated standards, such as the recent WHO 1st International Reference Panel for Genomic JAK2V617F. PMID:28427233
Perricone, Margherita; Palandri, Francesca; Ottaviani, Emanuela; Angelini, Mario; Bagli, Laura; Bellesia, Enrica; Donati, Meris; Gemmati, Donato; Zucchini, Patrizia; Mancini, Stefania; Marchica, Valentina; Trubini, Serena; De Matteis, Giovanna; Di Zacomo, Silvia; Favarato, Mosè; Fioroni, Annamaria; Bolzonella, Caterina; Maccari, Giorgia; Navaglia, Filippo; Gatti, Daniela; Toffolatti, Luisa; Orlandi, Linda; Laloux, Vèronique; Manfrini, Marco; Galieni, Piero; Giannini, Barbara; Tieghi, Alessia; Barulli, Sara; Serino, Maria Luisa; Maccaferri, Monica; Scortechini, Anna Rita; Giuliani, Nicola; Vallisa, Daniele; Bonifacio, Massimiliano; Accorsi, Patrizia; Salbe, Cristina; Fazio, Vinicio; Gusella, Milena; Toffoletti, Eleonora; Salvucci, Marzia; Svaldi, Mirija; Gherlinzoni, Filippo; Cassavia, Francesca; Orsini, Francesco; Martinelli, Giovanni
2017-05-16
To date, a plenty of techniques for the detection of JAK2V617F is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory.A network of 19 centers was established to 1) evaluate the inter- and intra-laboratory variability in JAK2V617F quantification, 2) identify the most robust assay for the standardization of the molecular test and 3) allow consistent interpretation of individual patient analysis results. The study was conceived in 3 different rounds, in which all centers had to blindly test DNA samples with different JAK2V617F allele burden (AB) using both quantitative and qualitative assays.The positivity of samples with an AB < 1% was not detected by qualitative assays. Conversely, laboratories performing the quantitative approach were able to determine the expected JAK2V617F AB. Quantitative results were reliable across all mutation loads with moderate variability at low AB (0.1 and 1%; CV = 0.46 and 0.77, respectively). Remarkably, all laboratories clearly distinguished between the 0.1 and 1% mutated samples.In conclusion, a qualitative approach is not sensitive enough to detect the JAK2V617F mutation, especially at low AB. On the contrary, the ipsogen JAK2 MutaQuant CE-IVD kit resulted in a high, efficient and sensitive quantification detection of all mutation loads. This study sets the basis for the standardization of molecular techniques for JAK2V617F determination, which will require the employment of approved operating procedures and the use of certificated standards, such as the recent WHO 1st International Reference Panel for Genomic JAK2V617F.
NASA Astrophysics Data System (ADS)
Asoka-Kumar, P.; Gossmann, H.-J.; Unterwald, F. C.; Feldman, L. C.; Leung, T. C.; Au, H. L.; Talyanski, V.; Nielsen, B.; Lynn, K. G.
1993-08-01
Positron annihilation in Si is a quantitaive, depth-sensitive technique for the detection of vacancylike defects or voids. A sensitivity of 5×1015 cm-3 for voidlike defects is easily achieved. The technique has been applied to a study of point-defect distributions in thin films of Si grown by molecular-beam epitaxy. A special procedure was developed to remove the influence of the native oxide on the positron measurement. 200-nm-thick films grown at temperatures between 475 and 560 °C show no defects below the sensitivity limit and are indistinguishable from the bulk substrate. So are films grown at 220 °C, provided a 2-min high-temperature anneal to a peak temperature of >=500 °C is executed every ~=30 nm during growth. If TRTA=450 °C, part of the film contains vacancylike defects to a concentration of ~=1018 cm-3. These results correlate well with current-voltage characteristics of p-n junctions grown with different rapid thermal anneal (RTA) temperatures. Ion scattering, with a defect sensitivity of ~=1%, shows no difference between films grown with different TRTA. Recrystallization of amorphous films, deposited at room temperature and annealed in situ at 550 °C, always leaves a significant defect concentration of ~=2×1018 cm-3; those defects are reduced but still present even after a 2-h 800 °C furnace anneal.
Chai, Qipeng; Li, Wenqin; Liu, Jingchuan; Geng, Zhiyuan; Tian, He; Zhu, Wei-hong
2015-01-01
Dye-sensitized solar cell (DSSC) is considered as a feasible route to the clean and renewable energy conversion technique. The commercial application requires further enhancements on photovoltaic efficiency and simplification on the device fabrication. For avoiding the unpreferable trade-off between photocurrent (JSC) and photovoltage (VOC), here we report the molecular engineering and comprehensive photovoltaic characterization of three cyclopentadithiophene-bridged D-A-π-A motif sensitizers with a change in donor group. We make a careful choice on the donor and conjugation bridge for synergistically increasing JSC and VOC. Comparing with the reference dye WS-2, the photovoltaic efficiency with the single component dye of WS-51 increases by 18%, among one of the rare examples in pure metal-free organic dyes exceeding 10% in combination with traditional iodine redox couples. Moreover, WS-51 exhibits several prominent merits on potentially scale-up industrial application: i) facile synthetic route to target molecule, ii) simple dipping procedure without requirement of co-sensitization, and iii) rapid dye adsorption capability. PMID:26066974
The principle and application of new PCR Technologies
NASA Astrophysics Data System (ADS)
Yu, Miao; Cao, Yue; Ji, Yubin
2017-12-01
Polymerase chain reaction (PCR) is essentially a selective DNA amplification technique commonlyapplied for genetic testing and molecular diagnosis because of its high specificity and sensitivity.PCR technologies as the key of molecular biology, has realized that the qualitative detection of absolute quantitative has been changed. It has produced a variety of new PCR technologies, such as extreme PCR, photonic PCR, o-amplification at lower denaturation temperature PCR, nanoparticle PCR and so on. In this paper, the principle and application of PCR technologies are reviewed, and its development is prospected too.
NASA Astrophysics Data System (ADS)
Nabok, A. V.; Tsargorodskaya, A.; Hassan, A. K.; Starodub, N. F.
2005-06-01
The environmental toxins, such as herbicides simazine and atrazine, and T2 mycotoxin were registered with the optical methods of surface plasmon resonance (SPR) and recently developed total internal reflection ellipsometry (TIRE). The immune assay approach was exploited for in situ registration of the above low molecular weight toxins with specific antibodies immobilised onto the gold surface via (poly)allylamine hydrochloride layer using electrostatic self-assembly (ESA) technique. The comparison of two methods of SPR and TIRE shows a higher sensitivity of the latter.
Li, Dong-Yan; He, Xi-Wen; Chen, Yang; Li, Wen-You; Zhang, Yu-Kui
2013-12-11
This work presented a novel strategy for the synthesis of the hybrid structure silica/CdTe/molecularly imprinted polymer (Si-NP/CdTe/MIP) to recognize and detect the template bovine hemoglobin (BHb). First, amino-functionalized silica nanoparticles (Si-NP) and carboxyl-terminated CdTe quantum dots (QDs) were assembled into composite nanoparticles (Si-NP/CdTe) using the EDC (1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride) chemistry. Next, Si-NP/CdTe/MIP was synthesized by anchoring molecularly imprinted polymer (MIP) layer on the surface of Si-NP/CdTe through the sol-gel technique and surface imprinting technique. The hybrid structure possessed the selectivity of molecular imprinting technique and the sensitivity of CdTe QDs as well as well-defined morphology. The binding experiment and fluorescence method demonstrated its special recognition performance toward the template BHb. Under the optimized conditions, the fluorescence intensity of the Si-NP/CdTe/MIP decreased linearly with the increase of BHb in the concentration range 0.02-2.1 μM, and the detection limit was 9.4 nM. Moreover, the reusability and reproducibility and the successful applications in practical samples indicated the synthesis of Si-NP/CdTe/MIP provided an alternative solution for special recognition and determination of protein from real samples.
Kim, Jeongho; Kim, Kyung Hwan; Oang, Key Young; Lee, Jae Hyuk; Hong, Kiryong; Cho, Hana; Huse, Nils; Schoenlein, Robert W; Kim, Tae Kyu; Ihee, Hyotcherl
2016-03-07
Characterization of transient molecular structures formed during chemical and biological processes is essential for understanding their mechanisms and functions. Over the last decade, time-resolved X-ray liquidography (TRXL) and time-resolved X-ray absorption spectroscopy (TRXAS) have emerged as powerful techniques for molecular and electronic structural analysis of photoinduced reactions in the solution phase. Both techniques make use of a pump-probe scheme that consists of (1) an optical pump pulse to initiate a photoinduced process and (2) an X-ray probe pulse to monitor changes in the molecular structure as a function of time delay between pump and probe pulses. TRXL is sensitive to changes in the global molecular structure and therefore can be used to elucidate structural changes of reacting solute molecules as well as the collective response of solvent molecules. On the other hand, TRXAS can be used to probe changes in both local geometrical and electronic structures of specific X-ray-absorbing atoms due to the element-specific nature of core-level transitions. These techniques are complementary to each other and a combination of the two methods will enhance the capability of accurately obtaining structural changes induced by photoexcitation. Here we review the principles of TRXL and TRXAS and present recent application examples of the two methods for studying chemical and biological processes in solution. Furthermore, we briefly discuss the prospect of using X-ray free electron lasers for the two techniques, which will allow us to keep track of structural dynamics on femtosecond time scales in various solution-phase molecular reactions.
Fong, Celesta; Dong, Aurelia W; Hill, Anita J; Boyd, Ben J; Drummond, Calum J
2015-07-21
Positron annihilation lifetime spectroscopy (PALS) has been shown to be highly sensitive to conformational, structural and microenvironmental transformations arising from subtle geometric changes in molecular geometry in self-assembling biomimetic systems. The ortho-positronium (oPs) may be considered an active probe that can provide information on intrinsic packing and mobility within low molecular weight solids, viscous liquids, and soft matter systems. In this perspective we provide a critical overview of the literature in this field, including the evolution of analysis software and experimental protocols with commentary upon the practical utility of PALS. In particular, we discuss how PALS can provide unique insight into the macroscopic transport properties of several porous biomembrane-like nanostructures and suggest how this insight may provide information on the release of drugs from these matrices to aid in developing therapeutic interventions. We discuss the potentially exciting and fruitful application of this technique to membrane dynamics, diffusion and permeability. We propose that PALS can provide novel molecular level information that is complementary to conventional characterisation techniques.
2011-01-01
Background Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. Results A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Conclusions Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach. PMID:21548975
Protein purification and analysis: next generation Western blotting techniques.
Mishra, Manish; Tiwari, Shuchita; Gomes, Aldrin V
2017-11-01
Western blotting is one of the most commonly used techniques in molecular biology and proteomics. Since western blotting is a multistep protocol, variations and errors can occur at any step reducing the reliability and reproducibility of this technique. Recent reports suggest that a few key steps, such as the sample preparation method, the amount and source of primary antibody used, as well as the normalization method utilized, are critical for reproducible western blot results. Areas covered: In this review, improvements in different areas of western blotting, including protein transfer and antibody validation, are summarized. The review discusses the most advanced western blotting techniques available and highlights the relationship between next generation western blotting techniques and its clinical relevance. Expert commentary: Over the last decade significant improvements have been made in creating more sensitive, automated, and advanced techniques by optimizing various aspects of the western blot protocol. New methods such as single cell-resolution western blot, capillary electrophoresis, DigiWest, automated microfluid western blotting and microchip electrophoresis have all been developed to reduce potential problems associated with the western blotting technique. Innovative developments in instrumentation and increased sensitivity for western blots offer novel possibilities for increasing the clinical implications of western blot.
Parasites under the Spotlight: Applications of Vibrational Spectroscopy to Malaria Research.
Perez-Guaita, David; Marzec, Katarzyna M; Hudson, Andrew; Evans, Corey; Chernenko, Tatyana; Matthäus, Christian; Miljkovic, Milos; Diem, Max; Heraud, Philip; Richards, Jack S; Andrew, Dean; Anderson, David A; Doerig, Christian; Garcia-Bustos, Jose; McNaughton, Don; Wood, Bayden R
2018-04-20
New technologies to diagnose malaria at high sensitivity and specificity are urgently needed in the developing world where the disease continues to pose a huge burden on society. Infrared and Raman spectroscopy-based diagnostic methods have a number of advantages compared with other diagnostic tests currently on the market. These include high sensitivity and specificity for detecting low levels of parasitemia along with ease of use and portability. Here, we review the application of vibrational spectroscopic techniques for monitoring and detecting malaria infection. We discuss the role of vibrational (infrared and Raman) spectroscopy in understanding the processes of parasite biology and its application to the study of interactions with antimalarial drugs. The distinct molecular phenotype that characterizes malaria infection and the high sensitivity enabling detection of low parasite densities provides a genuine opportunity for vibrational spectroscopy to become a front-line tool in the elimination of this deadly disease and provide molecular insights into the chemistry of this unique organism.
Pérez-Ruiz, Mercedes; Vicente, Diego; Navarro-Marí, José María
2008-07-01
Rapid diagnosis of acute viral and bacterial infections of the central nervous system (meningitis and encephalitis) is highly important for the clinical management of the patient and helps to establish early therapy that may solve life-threatening situations, to avoid unnecessary empirical treatments, to reduce hospital stay, and to facilitate appropriate interventions in the context of public health. Molecular techniques, especially real-time polymerase chain reaction, have become the fastest and most sensitive diagnostic procedures for autochthonous viral meningitis and encephalitis, and their role is becoming increasingly important for the diagnosis and control of most frequent acute bacterial meningitides. Automatic and closed systems may encourage the widespread and systematic use of molecular techniques for the diagnosis of these neurological syndromes in most laboratories.
New Insights for Diagnosis of Pineapple Fusariosis by MALDI-TOF MS Technique.
Santos, Cledir; Ventura, José Aires; Lima, Nelson
2016-08-01
Fusarium is one of the most economically important fungal genus, since it includes many pathogenic species which cause a wide range of plant diseases. Morphological or molecular biology identification of Fusarium species is a limiting step in the fast diagnosis and treatment of plant disease caused by these fungi. Mass spectrometry by matrix-assisted laser/desorption ionisation-time-of-flight (MALDI-TOF)-based fingerprinting approach was applied to the fungal growth monitoring and direct detection of strain Fusarium guttiforme E-480 inoculated in both pineapple cultivars Pérola and Imperial side shoots, that are susceptible and resistant, respectively, to this fungal strain. MALDI-TOF MS technique was capable to detect fungal molecular mass peaks in the susceptible pineapple stem side shoot tissue. It is assumed that these molecular masses are mainly constituted by ribosomal proteins. MALDI-TOF-based fingerprinting approach has herein been demonstrated to be sensitive and accurate for the direct detection of F. guttiforme E-480 molecular masses on both susceptible and resistant pineapple side stem free of any pre-treatment. According to the results obtained, the changing on molecular mass peaks of infected susceptible pineapple tissue together with the possibility of fungal molecular masses analysis into this pineapple tissue can be a good indication for an early diagnosis by MALDI-TOF MS of pineapple fusariosis.
Gago, Sara; Esteban, Cristina; Valero, Clara; Zaragoza, Oscar; Puig de la Bellacasa, Jorge; Buitrago, María José
2014-04-01
A molecular diagnostic technique based on real-time PCR was developed for the simultaneous detection of three of the most frequent causative agents of fungal opportunistic pneumonia in AIDS patients: Pneumocystis jirovecii, Histoplasma capsulatum, and Cryptococcus neoformans/Cryptococcus gattii. This technique was tested in cultured strains and in clinical samples from HIV-positive patients. The methodology used involved species-specific molecular beacon probes targeted to the internal transcribed spacer regions of the rDNA. An internal control was also included in each assay. The multiplex real-time PCR assay was tested in 24 clinical strains and 43 clinical samples from AIDS patients with proven fungal infection. The technique developed showed high reproducibility (r(2) of >0.98) and specificity (100%). For H. capsulatum and Cryptococcus spp., the detection limits of the method were 20 and 2 fg of genomic DNA/20 μl reaction mixture, respectively, while for P. jirovecii the detection limit was 2.92 log10 copies/20 μl reaction mixture. The sensitivity in vitro was 100% for clinical strains and 90.7% for clinical samples. The assay was positive for 92.5% of the patients. For one of the patients with proven histoplasmosis, P. jirovecii was also detected in a bronchoalveolar lavage sample. No PCR inhibition was detected. This multiplex real-time PCR technique is fast, sensitive, and specific and may have clinical applications.
Detecting molecules and cells labeled with magnetic particles using an atomic magnetometer
NASA Astrophysics Data System (ADS)
Yu, Dindi; Ruangchaithaweesuk, Songtham; Yao, Li; Xu, Shoujun
2012-09-01
The detection of magnetically labeled molecules and cells involves three essential parameters: sensitivity, spatial resolution, and molecular specificity. We report on the use of atomic magnetometry and its derivative techniques to achieve high performance in terms of all these parameters. With a sensitivity of 80 fT/√Hz for dc magnetic fields, we show that 7,000 streptavidin-conjugated magnetic microparticles magnetized by a permanent magnet produce a magnetic field of 650 pT; this result predicts that a single such particle can be detected during one second of signal averaging. Spatial information is obtained using a scanning magnetic imaging scheme. The spatial resolution is 20 μm with a detection distance of more than 1 cm; this distance is much longer than that in previous reports. The molecular specificity is achieved using force-induced remnant magnetization spectroscopy, which currently uses an atomic magnetometer for detection. As an example, we perform measurement of magnetically labeled human CD4+ T cells, whose count in the blood is the diagnostic criterion for human immunodeficiency virus infection. Magnetic particles that are specifically bound to the cells are resolved from nonspecifically bound particles and quantitatively correlate with the number of cells. The magnetic particles have an overall size of 2.8 μm, with a magnetic core in nanometer regime. The combination of our techniques is predicted to be useful in molecular and cellular imaging.
Zhou, Haiying; Yan, Ying; Ee, Xueping; Hunter, Daniel A; Akers, Walter J; Wood, Matthew D; Berezin, Mikhail Y
2016-12-01
Peripheral nerve injury evokes a complex cascade of chemical reactions including generation of molecular radicals. Conversely, the reactions within nerve induced by stress are difficult to directly detect or measure to establish causality. Monitoring these reactions in vivo would enable deeper understanding of the nature of the injury and healing processes. Here, we utilized near-infrared fluorescence molecular probes delivered via intra-neural injection technique to enable live, in vivo imaging of tissue response associated with nerve injury and stress. These initially quenched fluorescent probes featured specific sensitivity to hydroxyl radicals and become fluorescent upon encountering reactive oxygen species (ROS). Intraneurally delivered probes demonstrated rapid activation in injured rat sciatic nerve but minimal activation in normal, uninjured nerve. In addition, these probes reported activation within sciatic nerves of living rats after a stress caused by a pinprick stimulus to the abdomen. This imaging approach was more sensitive to detecting changes within nerves due to the induced stress than other techniques to evaluate cellular and molecular changes. Specifically, neither histological analysis of the sciatic nerves, nor the expression of pain and stress associated genes in dorsal root ganglia could provide statistically significant differences between the control and stressed groups. Overall, the results demonstrate a novel imaging approach to measure ROS in addition to the impact of ROS within nerve in live animals. Copyright © 2016 Elsevier Inc. All rights reserved.
Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.
Santa, Tomofumi
2011-01-01
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.
Molecularly imprinted hydroxyapatite thin film for bilirubin recognition.
Yang, Zhengpeng; Zhang, Chunjing
2011-11-15
A novel piezoelectric sensor has been developed for bilirubin (BR) detection, based on the modification of molecularly imprinted hydroxyapatite (HAP) film onto a quartz crystal by molecular imprinting and surface sol-gel technique. The performance of the developed BR biosensor was evaluated and the results indicated that a sensitive BR biosensor could be fabricated. The obtained BR biosensor presents high-selectivity monitoring of BR, better reproducibility, shorter response time (37 min), wider linear range (0.05-80μM) and lower detection limit (0.01μM). The analytical application of the BR biosensor confirms the feasibility of BR detection in serum sample. Copyright © 2011 Elsevier B.V. All rights reserved.
Intracellular applications of fluorescence correlation spectroscopy: prospects for neuroscience.
Kim, Sally A; Schwille, Petra
2003-10-01
Based on time-averaging fluctuation analysis of small fluorescent molecular ensembles in equilibrium, fluorescence correlation spectroscopy has recently been applied to investigate processes in the intracellular milieu. The exquisite sensitivity of fluorescence correlation spectroscopy provides access to a multitude of measurement parameters (rates of diffusion, local concentration, states of aggregation and molecular interactions) in real time with fast temporal and high spatial resolution. The introduction of dual-color cross-correlation, imaging, two-photon excitation, and coincidence analysis coupled with fluorescence correlation spectroscopy has expanded the utility of the technique to encompass a wide range of promising applications in living cells that may provide unprecedented insight into understanding the molecular mechanisms of intracellular neurobiological processes.
Liu, Meichuan; Ding, Xue; Yang, Qiwei; Wang, Yu; Zhao, Guohua; Yang, Nianjun
2017-06-05
A simple and highly sensitive photoelectrochemical (PEC) sensor towards Microcystin-LR (MC-LR), a kind of typical cyanobacterial toxin in water samples, was developed on a surface molecular imprinted TiO 2 coated multiwalled carbon nanotubes (MI-TiO 2 @CNTs) hybrid nanostructure. It was synthesized using a feasible two-step sol-gel method combining with in situ surface molecular imprinting technique (MIT). With a controllable core-shell tube casing structure, the resultant MI-TiO 2 @CNTs are enhanced greatly in visible-light driven response capacity. In comparison with the traditional TiO 2 (P25) and non-imprinted (NI-)TiO 2 @CNTs, the MI-TiO 2 @CNTs based PEC sensor showed a much higher photoelectric oxidation capacity towards MC-LR. Using this sensor, the determination of MC-LR was doable in a wide linear range from 1.0pM to 3.0nM with a high photocurrent response sensitivity. An outstanding selectivity towards MC-LR was further achieved with this sensor, proven by simultaneously monitoring 100-fold potential co-existing interferences. The superiority of the obtained MC-LR sensor in sensitivity and selectivity is mainly attributed to the high specific surface area and excellent photoelectric activity of TiO 2 @CNTs heterojunction structure, as well as the abundant active recognition sites on its functionalized molecular imprinting surface. A promising PEC analysis platform with high sensitivity and selectivity for MC-LR has thus been provided. Copyright © 2017 Elsevier B.V. All rights reserved.
Molecular imaging with radionuclides, a powerful technique for studying biological processes in vivo
NASA Astrophysics Data System (ADS)
Cisbani, E.; Cusanno, F.; Garibaldi, F.; Magliozzi, M. L.; Majewski, S.; Torrioli, S.; Tsui, B. M. W.
2007-02-01
Our team is carrying on a systematic study devoted to the design of a SPECT detector with submillimeter resolution and adequate sensitivity (1 cps/kBq). Such system will be used for functional imaging of biological processes at molecular level in small animal. The system requirements have been defined by two relevant applications: study of atherosclerotic plaques characterization and stem cells diffusion and homing. In order to minimize costs and implementation time, the gamma detector will be based—as much as possible—on conventional components: scintillator crystal and position sensitive PhotoMultipliers read by individual channel electronics. A coded aperture collimator should be adapted to maximize the efficiency. The optimal selection of the detector components is investigated by systematic use of Monte-Carlo simulations (and laboratory validation tests); and finally preliminary results are presented and discussed here.
In vivo molecular photoacoustic tomography of melanomas targeted by bioconjugated gold nanocages.
Kim, Chulhong; Cho, Eun Chul; Chen, Jingyi; Song, Kwang Hyun; Au, Leslie; Favazza, Christopher; Zhang, Qiang; Cobley, Claire M; Gao, Feng; Xia, Younan; Wang, Lihong V
2010-08-24
Early diagnosis, accurate staging, and image-guided resection of melanomas remain crucial clinical objectives for improving patient survival and treatment outcomes. Conventional techniques cannot meet this demand because of the low sensitivity, low specificity, poor spatial resolution, shallow penetration, and/or ionizing radiation. Here we overcome such limitations by combining high-resolution photoacoustic tomography (PAT) with extraordinarily optical absorbing gold nanocages (AuNCs). When bioconjugated with [Nle(4),D-Phe(7)]-alpha-melanocyte-stimulating hormone, the AuNCs can serve as a novel contrast agent for in vivo molecular PAT of melanomas with both exquisite sensitivity and high specificity. The bioconjugated AuNCs enhanced contrast approximately 300% more than the control, PEGylated AuNCs. The in vivo PAT quantification of the amount of AuNCs accumulated in melanomas was further validated with inductively coupled plasma mass spectrometry (ICP-MS).
Molecular identification of Coccidioides spp. in soil samples from Brazil
2011-01-01
Background Since 1991 several outbreaks of acute coccidioidomycosis (CM) were diagnosed in the semi-arid Northeast of Brazil, mainly related to disturbance of armadillo burrows caused by hunters while digging them for the capture of these animals. This activity causes dust contaminated with arthroconidia of Coccidioides posadasii, which, once inhaled, cause the mycosis. We report on the identification of C. posadasii in soil samples related to outbreaks of CM. Results Twenty four soil samples had their DNA extracted and subsequently submitted to a semi-nested PCR technique using specific primers. While only 6 (25%) soil samples were positive for C. posadasii by mice inoculation, all (100%) were positive by the molecular tool. Conclusion This methodology represents a simple, sensitive and specific molecular technique to determine the environmental distribution of Coccidioides spp. in endemic areas, but cannot distinguish the species. Moreover, it may be useful to identify culture isolates. Key-words: 1. Coccidioidomycosis. 2. Coccidioides spp. 3. C. posadasii. 4. Semi-arid. 5. Semi-nested PCR PMID:21575248
SYMPOSIUM ON MULTIMODALITY CARDIOVASCULAR MOLECULAR IMAGING IMAGING TECHNOLOGY - PART 2
de Kemp, Robert A.; Epstein, Frederick H.; Catana, Ciprian; Tsui, Benjamin M.W.; Ritman, Erik L.
2013-01-01
Rationale The ability to trace or identify specific molecules within a specific anatomic location provides insight into metabolic pathways, tissue components and tracing of solute transport mechanisms. With the increasing use of small animals for research such imaging must have sufficiently high spatial resolution to allow anatomic localization as well as sufficient specificity and sensitivity to provide an accurate description of the molecular distribution and concentration. Methods Imaging methods based on electromagnetic radiation, such as PET, SPECT, MRI and CT, are increasingly applicable due to recent advances in novel scanner hardware, image reconstruction software and availability of novel molecules which have enhanced sensitivity in these methodologies. Results Micro-PET has been advanced by development of detector arrays that provide higher resolution and positron emitting elements that allow new molecular tracers to be labeled. Micro-MRI has been improved in terms of spatial resolution and sensitivity by increased magnet field strength and development of special purpose coils and associated scan protocols. Of particular interest is the associated ability to image local mechanical function and solute transport processes which can be directly related to the molecular information. This is further strengthened by the synergistic integration of the PET with MRI. Micro-SPECT has been improved by use of coded aperture imaging approaches as well as image reconstruction algorithms which can better deal with the photon limited scan data. The limited spatial resolution can be partially overcome by integrating the SPECT with CT. Micro-CT by itself provides exquisite spatial resolution of anatomy, but recent developments of high spatial resolution photon counting and spectrally-sensitive imaging arrays, combined with x-ray optical devices, have promise for actual molecular identification by virtue of the chemical bond lengths of molecules, especially of bio-polymers. Conclusion With the increasing use of small animals for evaluating new clinical imaging techniques as well as providing increased insights into patho-physiological phenomena, the availability of improved detection systems, scanning protocols and associated software, the repertoire of molecular imaging is greatly increased in sensitivity and specificity. PMID:20457793
Advancing Porous Silicon Biosensor Technology for Use in Clinical Diagnostics
NASA Astrophysics Data System (ADS)
Bonanno, Lisa Marie
Inexpensive and robust analytical techniques for detecting molecular recognition events are in great demand in healthcare, food safety, and environmental monitoring. Despite vast research in this area, challanges remain to develop practical biomolecular platforms that, meet the rigorous demands of real-world applications. This includes maintaining low-cost devices that are sensitive and specific in complex test specimens, are stable after storage, have short assay time, and possess minimal complexity of instrumentation for readout. Nanostructured porous silicon (PSi) material has been identified as an ideal candidate towards achieving these goals and the past decade has seen diverse proof-of-principle studies developing optical-based sensing techniques. In Part 1 of this thesis, the impact of surface chemistry and PSi morphology on detection sensitivity of target molecules is investigated. Initial proof-of-concept that PSi devices facilitate detection of protein in whole blood is demonstrated. This work highlights the importance of material stability and blocking chemistry for sensor use in real world biological samples. In addition, the intrinisic filtering capability of the 3-D PSi morphology is shown as an advantage in complex solutions, such as whole blood. Ultimately, this initial work identified a need to improve detection sensitivity of the PSI biosensor technique to facilitate clinical diagnostic use over relevant target concentration ranges. The second part of this thesis, builds upon sensitivity challenges that are highlighted in the first part of the thesis and development of a surface-bound competitive inhibition immunoassay facilitated improved detection sensitivity of small molecular weight targets (opiates) over a relevant clinical concentration range. In addition, optimization of assay protocol addressed issues of maintaining stability of sensors after storage. Performance of the developed assay (specificity and sensitivity) was then validated in a blind clinical study that screened real patient urine samples (n=70) for opiates in collaboration with Strong Memorial Hospital Clinical Toxicology Laboratory. PSI sensor results showed improved clinical specificity over current commercial opiate immunoassay techniques and therefore, identified potential for a reduction in false-negative and false-positive screening results. Here, we demonstrate for the first time, successful clinical capability of a PSi sensor to detect opiates as a model target in real-world patient samples. The final part of this thesis explores novel sensor designs to leverage the tunable optical properties of PSi photonic devices and facilitate colorimetric readout of molecular recognition events by the unaided eye. Such a design is ideal for uncomplicated diagnostic screening at point-of-care as no instrumentation is needed for result readout. The photonic PSi transducers were integrated with target analyte-responsive hydrogels (TRAP-gels) that upon exposure to a target solution would swell and dissolute, inducing material property changes that were optically detected by the incorporated PSi transducer. This strategy extends target detection throughout the 3-ll internal volume of the PSi, improving upon current techniques that limit detection to the surface area (2-ll) of PSi. Work to acheive this approach involved design of TRAP-gel networks, polymer synthesis and characterization techniques, and optical characterization of the hybrid hydrogel-PSi material sensor. Successful implementation of a hybrid sensor design was exhibited for a. model chemical target (reducing agent), in which visual colorimetric change from red to green was observed for above-threshold exposure to the chemical target. In addition, initial proof-of-concept of an opiate responsive TRAP-gel is also demonstrated where cross-links are formed between antibody-antigen interactions and exposure to opiates induces bulk gel dissolution.
Niobium pentoxide: a promising surface-enhanced Raman scattering active semiconductor substrate
NASA Astrophysics Data System (ADS)
Shan, Yufeng; Zheng, Zhihui; Liu, Jianjun; Yang, Yong; Li, Zhiyuan; Huang, Zhengren; Jiang, Dongliang
2017-03-01
Surface-enhanced Raman scattering technique, as a powerful tool to identify the molecular species, has been severely restricted to the noble metals. The surface-enhanced Raman scattering substrates based on semiconductors would overcome the shortcomings of metal substrates and promote development of surface-enhanced Raman scattering technique in surface science, spectroscopy, and biomedicine studies. However, the detection sensitivity and enhancement effects of semiconductor substrates are suffering from their weak activities. In this work, a semiconductor based on Nb2O5 is reported as a new candidate for highly sensitive surface-enhanced Raman scattering detection of dye molecules. The largest enhancement factor value greater than 107 was observed with the laser excitation at 633 and 780 nm for methylene blue detection. As far as literature review shows, this is in the rank of the highest sensitivity among semiconductor materials; even comparable to the metal nanostructure substrates with "hot spots". The impressive surface-enhanced Raman scattering activities can be attributed to the chemical enhancement dominated by the photo-induced charge transfer, as well as the electromagnetic enhancement, which have been supported by the density-functional-theory and finite element method calculation results. The chemisorption of dye on Nb2O5 creates a new highest occupied molecular orbital and lowest unoccupied molecular orbital contributed by both fragments in the molecule-Nb2O5 system, which makes the charge transfer more feasible with longer excitation wavelength. In addition, the electromagnetic enhancement mechanism also accounts for two orders of magnitude enhancement in the overall enhancement factor value. This work has revealed Nb2O5 nanoparticles as a new semiconductor surface-enhanced Raman scattering substrate that is able to replace noble metals and shows great potentials applied in the fields of biology related.
Surface, Water, and Air Biocharacterization (SWAB) Flight Experiment
NASA Technical Reports Server (NTRS)
Castro, V. A.; Ott, C. M.; Pierson, D. L.
2012-01-01
The determination of risk from infectious disease during spaceflight missions is composed of several factors including both the concentration and characteristics of the microorganisms to which the crew are exposed. Thus, having a good understanding of the microbial ecology aboard spacecraft provides the necessary information to mitigate health risks to the crew. While preventive measures are taken to minimize the presence of pathogens on spacecraft, medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a specific culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. To address this bias in our understanding of the ISS environment, the Surface, Water, and Air Biocharacterization (SWAB) Flight Experiment was designed to investigate and develop monitoring technology to provide better microbial characterization. For the SWAB flight experiment, we hypothesized that environmental analysis using non-culture-based technologies would reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. Key findings during this experiment included: a) Generally, advanced molecular techniques were able to reveal a few organisms not recovered using culture-based methods; however, there is no indication that current monitoring is "missing" any medically significant bacteria or fungi. b) Molecular techniques have tremendous potential for microbial monitoring, however, sample preparation and data analysis present challenges for spaceflight hardware. c) Analytical results indicate that some molecular techniques, such as denaturing gradient gel electrophoresis (DGGE), can be much less sensitive than culture-based methods. d) More sensitive molecular techniques, such as quantitative polymerase chain reaction (QPCR), were able to identify viral DNA from ISS environments, suggesting potential transfer of the organism between crewmembers. In addition, the hardware selected for this experiment represented advances for next-generation sample collection. The advanced nature of this collection hardware was noted, when the Sartorius MD8 Air Port air sampler from the SWAB experiment remained on board ISS at the request of JAXA investigators, who intend to use it in completion of their microbial ecology experiment.
NASA Astrophysics Data System (ADS)
Krüger, Magnus; Huang, Mao-Dong; Becker-Roß, Helmut; Florek, Stefan; Ott, Ingo; Gust, Ronald
The development of high-resolution continuum source molecular absorption spectrometry made the quantification of fluorine feasible by measuring the molecular absorption as gallium monofluoride (GaF). Using this new technique, we developed on the example of 5-fluorouracil (5-FU) a graphite furnace method to quantify fluorine in organic molecules. The effect of 5-FU on the generation of the diatomic GaF molecule was investigated. The experimental conditions such as gallium nitrate amount, temperature program, interfering anions (represented as corresponding acids) and calibration for the determination of 5-FU in standard solution and in cellular matrix samples were investigated and optimized. The sample matrix showed no effect on the sensitivity of GaF molecular absorption. A simple calibration curve using an inorganic sodium fluoride solution can conveniently be used for the calibration. The described method is sensitive and the achievable limit of detection is 0.23 ng of 5-FU. In order to establish the concept of "fluorine as a probe in medicinal chemistry" an exemplary application was selected, in which the developed method was successfully demonstrated by performing cellular uptake studies of the 5-FU in human colon carcinoma cells.
The market trend analysis and prospects of cancer molecular diagnostics kits.
Seo, Ju Hwan; Lee, Joon Woo; Cho, Daemyeong
2018-01-01
The molecular diagnostics market can be broadly divided into PCR (rt-PCR, d-PCR), NGS(Next Generation Sequencing), Microarray, FISH(Fluorescent in situ-hybridization) and other categories, based on the diagnostic technique. Also, depending on the disease being diagnosed, the market can also be divided into cancer, infectious diseases, HIV/STDs (herpes, syphilis), and women's health issues such as breast cancer, cervical cancer, ovarian cancer, HPV(human papillomavirus), and vaginitis.Chromosome analysis (including Fluorescent In-situ Hybridization) is one type of blood cancer diagnostic method, which involves the direct detection of individual cells with chromosomal translocation, but there have been problems of sensitivity when using this method. PCR targeting individual genes or the RT (reverse transcription)-PCR method offers outstanding sensitivity, but one drawback is the risk of false-positive reaction caused by contamination of samples, etc. Blood cancer molecular diagnostics kits allow us to overcome these shortcomings, and related products have been under development, with a focus on improving detection sensitivity, enabling multiple tests, and reducing the cost and diagnostic time. Blood cancer molecular diagnostics is usually performed based on platforms such as PCR. The global market for blood cancer molecular diagnostics kits is $ 335.9 million as of 2016 and is expected to reach $ 6980 million in 2026 with an average annual growth rate of 32.9%. The market in South Korea is anticipated to grow at an average annual rate of 28.9%, from $ 3.75 million as of 2016 to $ 60.89 million in 2026. The Market for blood cancer molecular diagnostics kits is judged to be higher in growth possibility due to the increase in the number of cancer patients.
The use of biochemical methods in extraterrestrial life detection
NASA Astrophysics Data System (ADS)
McDonald, Gene
2006-08-01
Instrument development for in situ extraterrestrial life detection focuses primarily on the ability to distinguish between biological and non-biological material, mostly through chemical analysis for potential biosignatures (e.g., biogenic minerals, enantiomeric excesses). In constrast, biochemical analysis techniques commonly applied to Earth life focus primarily on the exploration of cellular and molecular processes, not on the classification of a given system as biological or non-biological. This focus has developed because of the relatively large functional gap between life and non-life on Earth today. Life on Earth is very diverse from an environmental and physiological point of view, but is highly conserved from a molecular point of view. Biochemical analysis techniques take advantage of this similarity of all terrestrial life at the molecular level, particularly through the use of biologically-derived reagents (e.g., DNA polymerases, antibodies), to enable analytical methods with enormous sensitivity and selectivity. These capabilities encourage consideration of such reagents and methods for use in extraterrestrial life detection instruments. The utility of this approach depends in large part on the (unknown at this time) degree of molecular compositional differences between extraterrestrial and terrestrial life. The greater these differences, the less useful laboratory biochemical techniques will be without significant modification. Biochemistry and molecular biology methods may need to be "de-focused" in order to produce instruments capable of unambiguously detecting a sufficiently wide range of extraterrestrial biochemical systems. Modern biotechnology tools may make that possible in some cases.
Kühnemund, Malte; Hernández-Neuta, Iván; Sharif, Mohd Istiaq; Cornaglia, Matteo; Gijs, Martin A.M.
2017-01-01
Abstract Single molecule quantification assays provide the ultimate sensitivity and precision for molecular analysis. However, most digital analysis techniques, i.e. droplet PCR, require sophisticated and expensive instrumentation for molecule compartmentalization, amplification and analysis. Rolling circle amplification (RCA) provides a simpler means for digital analysis. Nevertheless, the sensitivity of RCA assays has until now been limited by inefficient detection methods. We have developed a simple microfluidic strategy for enrichment of RCA products into a single field of view of a low magnification fluorescent sensor, enabling ultra-sensitive digital quantification of nucleic acids over a dynamic range from 1.2 aM to 190 fM. We prove the broad applicability of our analysis platform by demonstrating 5-plex detection of as little as ∼1 pg (∼300 genome copies) of pathogenic DNA with simultaneous antibiotic resistance marker detection, and the analysis of rare oncogene mutations. Our method is simpler, more cost-effective and faster than other digital analysis techniques and provides the means to implement digital analysis in any laboratory equipped with a standard fluorescent microscope. PMID:28077562
Molecular Rotation Signals: Molecule Chemistry and Particle Physics
NASA Astrophysics Data System (ADS)
Grabow, Jens-Uwe
2015-06-01
Molecules - large or small - are attractive academic resources, with numerous questions on their chemical behaviour as well as problems in fundamental physics now (or still) waiting to be answered: Targeted by high-resolution spectroscopy, a rotating molecular top can turn into a laboratory for molecule chemistry or a laboratory for particle physics. Once successfully entrained (many species - depending on size and chemical composition - have insufficient vapour pressures or are of transient nature, such that specifically designed pulsed-jet sources are required for their transfer into the gas phase or in-situ generation) into the collision-free environment of a supersonic-jet expansion, each molecular top comes with its own set of challenges, theoretically and experimentally: Multiple internal interactions are causing complicated energy level schemes and the resulting spectra will be rather difficult to predict theoretically. Experimentally, these spectra are difficult to assess and assign. With today's broad-banded chirp microwave techniques, finding and identifying such spectral features have lost their major drawback of being very time consuming for many molecules. For other molecules, the unrivalled resolution and sensitivity of the narrow-banded impulse microwave techniques provide a window to tackle - at the highest precision available to date - fundamental questions in physics, even particle physics - potentially beyond the standard model. Molecular charge distribution, properties of the chemical bond, details on internal dynamics and intermolecular interaction, the (stereo-chemical) molecular structure (including the possibility of their spatial separation) as well as potential evidence for tiny yet significant interactions encode their signature in pure molecular rotation subjected to time-domain microwave spectroscopic techniques. Ongoing exciting technical developments promise rapid progress. We present recent examples from Hannover, new directions, and an outlook at the future of molecular rotation spectroscopy.
Imaging and Force Recognition of Single Molecular Behaviors Using Atomic Force Microscopy
Li, Mi; Dang, Dan; Liu, Lianqing; Xi, Ning; Wang, Yuechao
2017-01-01
The advent of atomic force microscopy (AFM) has provided a powerful tool for investigating the behaviors of single native biological molecules under physiological conditions. AFM can not only image the conformational changes of single biological molecules at work with sub-nanometer resolution, but also sense the specific interactions of individual molecular pair with piconewton force sensitivity. In the past decade, the performance of AFM has been greatly improved, which makes it widely used in biology to address diverse biomedical issues. Characterizing the behaviors of single molecules by AFM provides considerable novel insights into the underlying mechanisms guiding life activities, contributing much to cell and molecular biology. In this article, we review the recent developments of AFM studies in single-molecule assay. The related techniques involved in AFM single-molecule assay were firstly presented, and then the progress in several aspects (including molecular imaging, molecular mechanics, molecular recognition, and molecular activities on cell surface) was summarized. The challenges and future directions were also discussed. PMID:28117741
NASA Astrophysics Data System (ADS)
Holman, Hoi-Ying N.; Goth-Goldstein, Regine; Blakely, Elanor A.; Bjornstad, Kathy; Martin, Michael C.; McKinney, Wayne R.
2000-05-01
Vibrational spectroscopy, when combined with synchrotron radiation-based (SR) microscopy, is a powerful new analytical tool with high spatial resolution for detecting biochemical changes in the individual living cells. In contrast to other microscopy methods that require fixing, drying, staining or labeling, SR-FTIR microscopy probes intact living cells providing a composite view of all of the molecular response and the ability to monitor the response over time in the same cell. Observed spectral changes include all types of lesions induced in that cell as well as cellular responses to external and internal stresses. These spectral changes combined with other analytical tools may provide a fundamental understanding of the key molecular mechanisms induced in response to stresses created by low- doses of chemicals. In this study we used the high spatial - resolution SR-FTIR vibrational spectromicroscopy as a sensitive analytical tool to detect chemical- and radiation- induced changes in individual human cells. Our preliminary spectral measurements indicate that this technique is sensitive enough to detect changes in nucleic acids and proteins of cells treated with environmentally relevant concentrations of dioxin. This technique has the potential to distinguish changes from exogenous or endogenous oxidative processes. Future development of this technique will allow rapid monitoring of cellular processes such as drug metabolism, early detection of disease, bio- compatibility of implant materials, cellular repair mechanisms, self assembly of cellular apparatus, cell differentiation and fetal development.
NASA Astrophysics Data System (ADS)
Xing, Yanlong; Fuss, Harald; Lademann, Jürgen; Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Patzelt, Alexa; Meinke, Martina C.; Jung, Sora; Esser, Norbert
2018-04-01
In this study, a new therapeutic drug monitoring approach has been tested based on the combination of CaF molecular absorption using high-resolution continuum source absorption spectrometry (HR-CSAS) and surface enhanced Raman spectroscopy (SERS). HR-CSAS with mini graphite tube was successfully tested for clinical therapeutic drug monitoring of the fluorine-containing drug capecitabine in sweat samples of cancer patients: It showed advantageous features of high selectivity (no interference from Cl), high sensitivity (characteristic mass of 0.1 ng at CaF 583.069 nm), low sample consumption (down to 30 nL) and fast measurement (no sample pretreatment and less than 1 min of responding time) in tracing the fluorine signal out of capecitabine. However, this technique has the disadvantage of the total loss of the drug's structure information after burning the sample at very high temperature. Therefore, a new concept of combining HR-CSAS with a non-destructive spectroscopic method (SERS) was proposed for the sensitive sensing and specific identification of capecitabine. We tested and succeed in obtaining the molecular characteristics of the metabolite of capecitabine (named 5-fluorouracil) by the non-destructive SERS technique. With the results shown in this work, it is demonstrated that the combined spectroscopic technique of HR-CSAS and SERS will be very useful in efficient therapeutic drug monitoring in the future.
Walker, Martin; Basáñez, María-Gloria; Ouédraogo, André Lin; Hermsen, Cornelus; Bousema, Teun; Churcher, Thomas S
2015-01-16
Quantitative molecular methods (QMMs) such as quantitative real-time polymerase chain reaction (q-PCR), reverse-transcriptase PCR (qRT-PCR) and quantitative nucleic acid sequence-based amplification (QT-NASBA) are increasingly used to estimate pathogen density in a variety of clinical and epidemiological contexts. These methods are often classified as semi-quantitative, yet estimates of reliability or sensitivity are seldom reported. Here, a statistical framework is developed for assessing the reliability (uncertainty) of pathogen densities estimated using QMMs and the associated diagnostic sensitivity. The method is illustrated with quantification of Plasmodium falciparum gametocytaemia by QT-NASBA. The reliability of pathogen (e.g. gametocyte) densities, and the accompanying diagnostic sensitivity, estimated by two contrasting statistical calibration techniques, are compared; a traditional method and a mixed model Bayesian approach. The latter accounts for statistical dependence of QMM assays run under identical laboratory protocols and permits structural modelling of experimental measurements, allowing precision to vary with pathogen density. Traditional calibration cannot account for inter-assay variability arising from imperfect QMMs and generates estimates of pathogen density that have poor reliability, are variable among assays and inaccurately reflect diagnostic sensitivity. The Bayesian mixed model approach assimilates information from replica QMM assays, improving reliability and inter-assay homogeneity, providing an accurate appraisal of quantitative and diagnostic performance. Bayesian mixed model statistical calibration supersedes traditional techniques in the context of QMM-derived estimates of pathogen density, offering the potential to improve substantially the depth and quality of clinical and epidemiological inference for a wide variety of pathogens.
Development and Testing of Molecular Adsorber Coatings
NASA Technical Reports Server (NTRS)
Abraham, Nithin; Hasegawa, Mark; Straka, Sharon
2012-01-01
The effect of on-orbit molecular contamination has the potential to degrade the performance of spaceflight hardware and diminish the lifetime of the spacecraft. For example, sensitive surfaces, such as optical surfaces, electronics, detectors, and thermal control surfaces, are vulnerable to the damaging effects of contamination from outgassed materials. The current solution to protect these surfaces is through the use of zeolite coated ceramic adsorber pucks. However, these pucks and its additional complex mounting hardware requirements result in several disadvantages, such as size, weight, and cost related concerns, that impact the spacecraft design and the integration and test schedule. As a result, a new innovative molecular adsorber coating was developed as a sprayable alternative to mitigate the risk of on-orbit molecular contamination. In this study, the formulation for molecular adsorber coatings was optimized using various binders, pigment treatment methods, binder to pigment ratios, thicknesses, and spray application techniques. The formulations that passed coating adhesion and vacuum thermal cycling tests were further tested for its adsorptive capacity. Accelerated molecular capacitance tests were performed in an innovatively designed multi-unit system containing idealized contaminant sources. This novel system significantly increased the productivity of the testing phase for the various formulations that were developed. Work performed during the development and testing phases has demonstrated successful application of molecular adsorber coatings onto metallic substrates, as well as, very promising results for the adhesion performance and the molecular capacitance of the coating. Continued testing will assist in the qualification of molecular adsorber coatings for use on future contamination sensitive spaceflight missions.
Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression
NASA Astrophysics Data System (ADS)
Wong, Chak P.; Gump, Jared C.
2006-07-01
Explosive formulations with reduced-sensitivity RDX showed reduced shock sensitivity using Naval Ordnance Laboratory (NOL) Large Scale Gap Test, compared with similar formulations using standard RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light on the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. I-RDX®, a form of reduced- sensitivity RDX was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transform IR (FTIR). The pressure dependence of the Raman mode frequencies of I-RDX® was determined and compared with that of standard RDX. The behavior of I-RDX® near the pressure at which standard RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph is presented.
Scolaro, Loretta; Lorenser, Dirk; Madore, Wendy-Julie; Kirk, Rodney W.; Kramer, Anne S.; Yeoh, George C.; Godbout, Nicolas; Sampson, David D.; Boudoux, Caroline; McLaughlin, Robert A.
2015-01-01
Molecular imaging using optical techniques provides insight into disease at the cellular level. In this paper, we report on a novel dual-modality probe capable of performing molecular imaging by combining simultaneous three-dimensional optical coherence tomography (OCT) and two-dimensional fluorescence imaging in a hypodermic needle. The probe, referred to as a molecular imaging (MI) needle, may be inserted tens of millimeters into tissue. The MI needle utilizes double-clad fiber to carry both imaging modalities, and is interfaced to a 1310-nm OCT system and a fluorescence imaging subsystem using an asymmetrical double-clad fiber coupler customized to achieve high fluorescence collection efficiency. We present, to the best of our knowledge, the first dual-modality OCT and fluorescence needle probe with sufficient sensitivity to image fluorescently labeled antibodies. Such probes enable high-resolution molecular imaging deep within tissue. PMID:26137379
Advances in Molecular Rotational Spectroscopy for Applied Science
NASA Astrophysics Data System (ADS)
Harris, Brent; Fields, Shelby S.; Pulliam, Robin; Muckle, Matt; Neill, Justin L.
2017-06-01
Advances in chemical sensitivity and robust, solid-state designs for microwave/millimeter-wave instrumentation compel the expansion of molecular rotational spectroscopy as research tool into applied science. It is familiar to consider molecular rotational spectroscopy for air analysis. Those techniques for molecular rotational spectroscopy are included in our presentation of a more broad application space for materials analysis using Fourier Transform Molecular Rotational Resonance (FT-MRR) spectrometers. There are potentially transformative advantages for direct gas analysis of complex mixtures, determination of unknown evolved gases with parts per trillion detection limits in solid materials, and unambiguous chiral determination. The introduction of FT-MRR as an alternative detection principle for analytical chemistry has created a ripe research space for the development of new analytical methods and sampling equipment to fully enable FT-MRR. We present the current state of purpose-built FT-MRR instrumentation and the latest application measurements that make use of new sampling methods.
NASA Astrophysics Data System (ADS)
So, Stephen; Wysocki, Gerard
2010-02-01
Faraday Rotation Spectroscopy (FRS) is a polarization based spectroscopic technique which can provide higher sensitivity concentration measurements of paramagnetic gases and free radicals than direct absorption spectroscopic techniques. We have developed sensor systems which require only 0.2W to perform TDLAS (tunable diode laser absorption spectroscopy), and can additionally be quickly duty cycled, enabling operation in wireless sensor networks of laser-based trace gas sensors We adapted our integrated TDLAS electronics to perform FRS in a compact and more sensitive system for quantification of molecular oxygen (O2) using a 762.3nm VCSEL in the A band. Using an AC magnetic field, we demonstrate detector noise dominated performance, achieving 2.1×10-6/Hz1/2 equivalent detectable fractional absorption and a minimum detection limit of 462 ppmv O2 in 1 second in a 15cm path. At longer paths and integration times, such a sensor will enable oxygen measurements at biotic respiration levels (<1ppmv) to measure CO2 - O2 exchange for mapping natural exchange of greenhouse gases. Potential improvement of detection limits by increasing various system performance parameters is described.
Yu, Peiqiang
2013-02-20
Heat-related processing of cereal grains, legume seeds, and oil seeds could be used to improve nutrient availability in ruminants. However, different types of processing may have a different impact on intrinsic structure of tissues. To date, there is little research on structure changes after processing within intact tissues. The synchrotron-based molecular imaging technique enables us to detect inherent structure change on a molecular level. The objective of this study was to visualize tissue of black-type canola (Brassica) seed with a thick seed coat after heat-related processing in a chemical way using the synchrotron imaging technique. The results showed that the chemical images of protein amides were obtained through the imaging technique for the raw, wet, and dry heated black type of canola seed tissues. It seems that different types of processing have a different impact on the protein spectral profile in the black type of canola tissues. Wet heating had a greater impact on the protein α-helix to β-sheet ratio than dry heating. Both dry and wet heating resulted in different patterns in amide I, the second derivative, and FSD spectra. However, the exact differences in the tissue images are relatively difficult to be obtained through visual comparison. Future studies should focus on (1) comparing the response and sensitivity of canola seeds to various processing methods between the yellow-type and black-type of canola seeds; (2) developing a sensitive method to compare the image difference between tissues and between treatments; (3) developing a method to link images to nutrient digestion, and (4) revealing how structure changes affect nutrient absorption in humans and animals.
"Peak tracking chip" for label-free optical detection of bio-molecular interaction and bulk sensing.
Bougot-Robin, Kristelle; Li, Shunbo; Zhang, Yinghua; Hsing, I-Ming; Benisty, Henri; Wen, Weijia
2012-10-21
A novel imaging method for bulk refractive index sensing or label-free bio-molecular interaction sensing is presented. This method is based on specially designed "Peak tracking chip" (PTC) involving "tracks" of adjacent resonant waveguide gratings (RWG) "micropads" with slowly evolving resonance position. Using a simple camera the spatial information robustly retrieves the diffraction efficiency, which in turn transduces either the refractive index of the liquids on the tracks or the effective thickness of an immobilized biological layer. Our intrinsically multiplex chip combines tunability and versatility advantages of dielectric guided wave biochips without the need of costly hyperspectral instrumentation. The current success of surface plasmon imaging techniques suggests that our chip proposal could leverage an untapped potential to routinely extend such techniques in a convenient and sturdy optical configuration toward, for instance for large analytes detection. PTC design and fabrication are discussed with challenging process to control micropads properties by varying their period (step of 2 nm) or their duty cycle through the groove width (steps of 4 nm). Through monochromatic imaging of our PTC, we present experimental demonstration of bulk index sensing on the range [1.33-1.47] and of surface biomolecule detection of molecular weight 30 kDa in aqueous solution using different surface densities. A sensitivity of the order of 10(-5) RIU for bulk detection and a sensitivity of the order of ∼10 pg mm(-2) for label-free surface detection are expected, therefore opening a large range of application of our chip based imaging technique. Exploiting and chip design, we expect as well our chip to open new direction for multispectral studies through imaging.
Bergman, Nina; Shevchenko, Denys; Bergquist, Jonas
2014-01-01
This review summarizes various approaches for the analysis of low molecular weight (LMW) compounds by different laser desorption/ionization mass spectrometry techniques (LDI-MS). It is common to use an agent to assist the ionization, and small molecules are normally difficult to analyze by, e.g., matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) using the common matrices available today, because the latter are generally small organic compounds themselves. This often results in severe suppression of analyte peaks, or interference of the matrix and analyte signals in the low mass region. However, intrinsic properties of several LDI techniques such as high sensitivity, low sample consumption, high tolerance towards salts and solid particles, and rapid analysis have stimulated scientists to develop methods to circumvent matrix-related issues in the analysis of LMW molecules. Recent developments within this field as well as historical considerations and future prospects are presented in this review.
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing; Ibrahim, Yehia M.; Burnum-Johnson, Kristin E.; Orton, Daniel J.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.; Baker, Erin S.
2017-01-01
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits. PMID:28301728
CMOS Time-Resolved, Contact, and Multispectral Fluorescence Imaging for DNA Molecular Diagnostics
Guo, Nan; Cheung, Ka Wai; Wong, Hiu Tung; Ho, Derek
2014-01-01
Instrumental limitations such as bulkiness and high cost prevent the fluorescence technique from becoming ubiquitous for point-of-care deoxyribonucleic acid (DNA) detection and other in-field molecular diagnostics applications. The complimentary metal-oxide-semiconductor (CMOS) technology, as benefited from process scaling, provides several advanced capabilities such as high integration density, high-resolution signal processing, and low power consumption, enabling sensitive, integrated, and low-cost fluorescence analytical platforms. In this paper, CMOS time-resolved, contact, and multispectral imaging are reviewed. Recently reported CMOS fluorescence analysis microsystem prototypes are surveyed to highlight the present state of the art. PMID:25365460
[THE ROLE OF SYSTEM QUORUM SENSING UNDER CHRONIC UROGENITAL CHLAMYDIA INFECTION].
2015-10-01
It is established that system quorum sensing (QS) assure social behavior of bacteria in regulation of genes of virulence and generalization of inflectional inflammatory process under chronic urogenital chlamydia infection. The techniques of gas chromatography and mass-spectrometry were applied to detect molecular markers of generalization of infectious process under urogenital chlamydiasis--activators of QS microbes (lactones, quinolones, furan ethers). The developed diagnostic gas chromatography and mass-spectrometry criteria of indexation of molecular markers under chronic urogenital chlamydia infection have high level of diagnostic sensitivity, specificity and prognostic value of positive and negative result. The application of techniques of gas chromatography and mass-spectrometry permits enhancing effectiveness of diagnostic of chronic inflectional inflammatory diseases of urogenital system of chlamydia etiology with identification of prognostic criteria of generalization of infectious process and subsequent prescription of timely and appropriate therapy
Risk Assessment of Radiation Exposure using Molecular Biodosimetry
NASA Technical Reports Server (NTRS)
Elliott, Todd F.; George, K.; Hammond, D. K.; Cucinotta, F. A.
2007-01-01
Current cytogenetic biodosimetry methods would be difficult to adapt to spaceflight operations, because they require toxic chemicals and a substantial amount of time to perform. In addition, current biodosimetry techniques are limited to whole body doses over about 10cGy. Development of new techniques that assess radiation exposure response at the molecular level could overcome these limitations and have important implications in the advancement of biodosimetry. Recent technical advances include expression profiling at the transcript and protein level to assess multiple biomarkers of exposure, which may lead to the development of a radiation biomarker panel revealing possible fingerprints of individual radiation sensitivity. So far, many biomarkers of interest have been examined in their response to ionizing radiation, such as cytokines and members of the DNA repair pathway. New technology, such as the Luminex system can analyze many biomarkers simultaneously in one sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartig, Kyle C.; Ghebregziabher, Isaac; Jovanovic, Igor
The ability to perform not only elementally but also isotopically sensitive detection and analysis at standoff distances is important for remote sensing applications in diverse ares, such as nuclear nonproliferation, environmental monitoring, geophysics, and planetary science. We demonstrate isotopically sensitive real-time standoff detection of uranium by the use of femtosecond filament-induced laser ablation molecular isotopic spectrometry. A uranium oxide molecular emission isotope shift of 0.05 ± 0.007 nm is reported at 593.6 nm. We implement both spectroscopic and acoustic diagnostics to characterize the properties of uranium plasma generated at different filament- uranium interaction points. The resulting uranium oxide emission exhibitsmore » a nearly constant signal-to-background ratio over the length of the filament, unlike the uranium atomic and ionic emission, for which the signal-to-background ratio varies significantly along the filament propagation. This is explained by the different rates of increase of plasma density and uranium oxide density along the filament length resulting from spectral and temporal evolution of the filament along its propagation. Lastly, the results provide a basis for the optimal use of filaments for standoff detection and analysis of uranium isotopes and indicate the potential of the technique for a wider range of remote sensing applications that require isotopic sensitivity.« less
Hartig, Kyle C.; Ghebregziabher, Isaac; Jovanovic, Igor
2017-01-01
The ability to perform not only elementally but also isotopically sensitive detection and analysis at standoff distances is impor-tant for remote sensing applications in diverse ares, such as nuclear nonproliferation, environmental monitoring, geophysics, and planetary science. We demonstrate isotopically sensitive real-time standoff detection of uranium by the use of femtosecond filament-induced laser ablation molecular isotopic spectrometry. A uranium oxide molecular emission isotope shift of 0.05 ± 0.007 nm is reported at 593.6 nm. We implement both spectroscopic and acoustic diagnostics to characterize the properties of uranium plasma generated at different filament-uranium interaction points. The resulting uranium oxide emis-sion exhibits a nearly constant signal-to-background ratio over the length of the filament, unlike the uranium atomic and ionic emission, for which the signal-to-background ratio varies significantly along the filament propagation. This is explained by the different rates of increase of plasma density and uranium oxide density along the filament length resulting from spectral and temporal evolution of the filament along its propagation. The results provide a basis for the optimal use of filaments for standoff detection and analysis of uranium isotopes and indicate the potential of the technique for a wider range of remote sensing applications that require isotopic sensitivity. PMID:28272450
Hartig, Kyle C.; Ghebregziabher, Isaac; Jovanovic, Igor
2017-03-08
The ability to perform not only elementally but also isotopically sensitive detection and analysis at standoff distances is important for remote sensing applications in diverse ares, such as nuclear nonproliferation, environmental monitoring, geophysics, and planetary science. We demonstrate isotopically sensitive real-time standoff detection of uranium by the use of femtosecond filament-induced laser ablation molecular isotopic spectrometry. A uranium oxide molecular emission isotope shift of 0.05 ± 0.007 nm is reported at 593.6 nm. We implement both spectroscopic and acoustic diagnostics to characterize the properties of uranium plasma generated at different filament- uranium interaction points. The resulting uranium oxide emission exhibitsmore » a nearly constant signal-to-background ratio over the length of the filament, unlike the uranium atomic and ionic emission, for which the signal-to-background ratio varies significantly along the filament propagation. This is explained by the different rates of increase of plasma density and uranium oxide density along the filament length resulting from spectral and temporal evolution of the filament along its propagation. Lastly, the results provide a basis for the optimal use of filaments for standoff detection and analysis of uranium isotopes and indicate the potential of the technique for a wider range of remote sensing applications that require isotopic sensitivity.« less
NASA Astrophysics Data System (ADS)
Hartig, Kyle C.; Ghebregziabher, Isaac; Jovanovic, Igor
2017-03-01
The ability to perform not only elementally but also isotopically sensitive detection and analysis at standoff distances is impor-tant for remote sensing applications in diverse ares, such as nuclear nonproliferation, environmental monitoring, geophysics, and planetary science. We demonstrate isotopically sensitive real-time standoff detection of uranium by the use of femtosecond filament-induced laser ablation molecular isotopic spectrometry. A uranium oxide molecular emission isotope shift of 0.05 ± 0.007 nm is reported at 593.6 nm. We implement both spectroscopic and acoustic diagnostics to characterize the properties of uranium plasma generated at different filament-uranium interaction points. The resulting uranium oxide emis-sion exhibits a nearly constant signal-to-background ratio over the length of the filament, unlike the uranium atomic and ionic emission, for which the signal-to-background ratio varies significantly along the filament propagation. This is explained by the different rates of increase of plasma density and uranium oxide density along the filament length resulting from spectral and temporal evolution of the filament along its propagation. The results provide a basis for the optimal use of filaments for standoff detection and analysis of uranium isotopes and indicate the potential of the technique for a wider range of remote sensing applications that require isotopic sensitivity.
Black Molecular Adsorber Coatings for Spaceflight Applications
NASA Technical Reports Server (NTRS)
Abraham, Nithin Susan; Hasegawa, Mark Makoto; Straka, Sharon A.
2014-01-01
The molecular adsorber coating is a new technology that was developed to mitigate the risk of on-orbit molecular contamination on spaceflight missions. The application of this coating would be ideal near highly sensitive, interior surfaces and instruments that are negatively impacted by outgassed molecules from materials, such as plastics, adhesives, lubricants, epoxies, and other similar compounds. This current, sprayable paint technology is comprised of inorganic white materials made from highly porous zeolite. In addition to good adhesion performance, thermal stability, and adsorptive capability, the molecular adsorber coating offers favorable thermal control characteristics. However, low reflectivity properties, which are typically offered by black thermal control coatings, are desired for some spaceflight applications. For example, black coatings are used on interior surfaces, in particular, on instrument baffles for optical stray light control. Similarly, they are also used within light paths between optical systems, such as telescopes, to absorb light. Recent efforts have been made to transform the white molecular adsorber coating into a black coating with similar adsorptive properties. This result is achieved by optimizing the current formulation with black pigments, while still maintaining its adsorption capability for outgassing control. Different binder to pigment ratios, coating thicknesses, and spray application techniques were explored to develop a black version of the molecular adsorber coating. During the development process, coating performance and adsorption characteristics were studied. The preliminary work performed on black molecular adsorber coatings thus far is very promising. Continued development and testing is necessary for its use on future contamination sensitive spaceflight missions.
Black molecular adsorber coatings for spaceflight applications
NASA Astrophysics Data System (ADS)
Abraham, Nithin S.; Hasegawa, Mark M.; Straka, Sharon A.
2014-09-01
The molecular adsorber coating is a new technology that was developed to mitigate the risk of on-orbit molecular contamination on spaceflight missions. The application of this coating would be ideal near highly sensitive, interior surfaces and instruments that are negatively impacted by outgassed molecules from materials, such as plastics, adhesives, lubricants, epoxies, and other similar compounds. This current, sprayable paint technology is comprised of inorganic white materials made from highly porous zeolite. In addition to good adhesion performance, thermal stability, and adsorptive capability, the molecular adsorber coating offers favorable thermal control characteristics. However, low reflectivity properties, which are typically offered by black thermal control coatings, are desired for some spaceflight applications. For example, black coatings are used on interior surfaces, in particular, on instrument baffles for optical stray light control. Similarly, they are also used within light paths between optical systems, such as telescopes, to absorb light. Recent efforts have been made to transform the white molecular adsorber coating into a black coating with similar adsorptive properties. This result is achieved by optimizing the current formulation with black pigments, while still maintaining its adsorption capability for outgassing control. Different binder to pigment ratios, coating thicknesses, and spray application techniques were explored to develop a black version of the molecular adsorber coating. During the development process, coating performance and adsorption characteristics were studied. The preliminary work performed on black molecular adsorber coatings thus far is very promising. Continued development and testing is necessary for its use on future contamination sensitive spaceflight missions.
Analyzing Single Giant Unilamellar Vesicles With a Slotline-Based RF Nanometer Sensor
Cui, Yan; Kenworthy, Anne K.; Edidin, Michael; ...
2016-03-11
Novel techniques that enable reagent free detection and analysis of single cells are of great interest for the development of biological and medical sciences, as well as point-of-care health service technologies. Highly sensitive and broadband RF sensors are promising candidates for such a technique. In this paper, we present a highly sensitive and tunable RF sensor, which is based on interference processes and built with a 100-nm slotline structure. The highly concentrated RF fields, up to ~ 1.76×10 7 V/m, enable strong interactions between giant unilamellar vesicles (GUVs) and fields for high-sensitivity operations. We also provide two modeling approaches tomore » extract cell dielectric properties from measured scattering parameters. GUVs of different molecular compositions are synthesized and analyzed with the RF sensor at ~ 2, ~ 2.5, and ~ 2.8 GHz with an initial |S 21| min of ~ -100 dB. Corresponding GUV dielectric properties are obtained. Finally, a one-dimensional scanning of single GUV is also demonstrated.« less
Improved detection of endoparasite DNA in soil sample PCR by the use of anti-inhibitory substances.
Krämer, F; Vollrath, T; Schnieder, T; Epe, C
2002-09-26
Although there have been numerous microbial examinations of soil for the presence of human pathogenic developmental parasite stages of Ancylostoma caninum and Toxocara canis, molecular techniques (e.g. DNA extraction, purification and subsequent PCR) have scarcely been applied. Here, DNA preparations of soil samples artificially contaminated with genomic DNA or parasite eggs were examined by PCR. A. caninum and T. canis-specific primers based on the ITS-2 sequence were used for amplification. After the sheer DNA preparation a high content of PCR-interfering substances was still detectable. Subsequently, two different inhibitors of PCR-interfering agents (GeneReleaser, Bioventures Inc. and Maximator, Connex GmbH) were compared in PCR. Both substances increased PCR sensitivity greatly. However, comparison of the increase in sensitivity achieved with the two compounds demonstrated the superiority of Maximator, which enhanced sensitivity to the point of permitting positive detection of a single A. caninum egg and three T. canis eggs in a soil sample. This degree of sensitivity could not be achieved with GeneReleaser for either parasite Furthermore, Maximator not only increased sensitivity; it also cost less, required less time and had a lower risk of contamination. Future applications of molecular methods in epidemiological examinations of soil samples are discussed/elaborated.
Nondestructive surface analysis for material research using fiber optic vibrational spectroscopy
NASA Astrophysics Data System (ADS)
Afanasyeva, Natalia I.
2001-11-01
The advanced methods of fiber optical vibrational spectroscopy (FOVS) has been developed in conjunction with interferometer and low-loss, flexible, and nontoxic optical fibers, sensors, and probes. The combination of optical fibers and sensors with Fourier Transform (FT) spectrometer has been used in the range from 2.5 to 12micrometers . This technique serves as an ideal diagnostic tool for surface analysis of numerous and various diverse materials such as complex structured materials, fluids, coatings, implants, living cells, plants, and tissue. Such surfaces as well as living tissue or plants are very difficult to investigate in vivo by traditional FT infrared or Raman spectroscopy methods. The FOVS technique is nondestructive, noninvasive, fast (15 sec) and capable of operating in remote sampling regime (up to a fiber length of 3m). Fourier transform infrared (FTIR) and Raman fiber optic spectroscopy operating with optical fibers has been suggested as a new powerful tool. These techniques are highly sensitive techniques for structural studies in material research and various applications during process analysis to determine molecular composition, chemical bonds, and molecular conformations. These techniques could be developed as a new tool for quality control of numerous materials as well as noninvasive biopsy.
High Sensitivity, Low Power Nano Sensors and Devices for Chemical Sensing
NASA Technical Reports Server (NTRS)
Li, Jing; Powell, Dan; Getty, Stephanie; Lu, Yi-Jiang
2004-01-01
The chemical sensor market has been projected to grow to better than $40 billion dollars worldwide within the next 10 years. Some of the primary motivations to develop nanostructured chemical sensors are monitoring and control of environmental pollution; improved diagnostics for consumption; improvement in measurement precision and accuracy; and improved detection limits for Homeland security, battlefield environments, and process and quality control of industrial applications. In each of these applications, there is demand for sensitivity, selectivity and stability of environmental and biohazard detection and capture beyond what is currently commercially available. Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. One such nanotechnology-enabled chemical sensor has been developed at NASA Ames leveraging nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxide nanobelts or nanowires, as a sensing medium bridging a pair of interdigitated electrodes (IDE) realized through a silicon-based microfabrication and micromachining technique. The DE fingers are fabricated on a silicon substrate using standard photolithography and thin film metallization techniques. It is noteworthy that the fabrication techniques employed are not confined to the silicon substrate. Through spin casting and careful substrate selection (i.e. clothing, glass, polymer, etc.), additional degrees of freedom can be exploited to enhance sensitivity or to conform to unique applications. Both in-situ growth of nanostructured materials and casting of nanostructured dispersions were used to produce analogous chemical sensing devices.
Phase-Sensitive Surface Plasmon Resonance Sensors: Recent Progress and Future Prospects
Deng, Shijie; Wang, Peng; Yu, Xinglong
2017-01-01
Surface plasmon resonance (SPR) is an optical sensing technique that is capable of performing real-time, label-free and high-sensitivity monitoring of molecular interactions. SPR biosensors can be divided according to their operating principles into angle-, wavelength-, intensity- and phase-interrogated devices. With their complex optical configurations, phase-interrogated SPR sensors generally provide higher sensitivity and throughput, and have thus recently emerged as prominent biosensing devices. To date, several methods have been developed for SPR phase interrogation, including heterodyne detection, polarimetry, shear interferometry, spatial phase modulation interferometry and temporal phase modulation interferometry. This paper summarizes the fundamentals of phase-sensitive SPR sensing, reviews the available methods for phase interrogation of these sensors, and discusses the future prospects for and trends in the development of this technology. PMID:29206182
Design Principles of Nanoparticles as Contrast Agents for Magnetic Resonance Imaging
NASA Astrophysics Data System (ADS)
Shan, Liang; Gu, Xinbin; Wang, Paul
2013-09-01
Molecular imaging is an emerging field that introduces molecular agents into traditional imaging techniques, enabling visualization, characterization and measurement of biological processes at the molecular and cellular levels in humans and other living systems. The promise of molecular imaging lies in its potential for selective potency by targeting biomarkers or molecular targets and the imaging agents serve as reporters for the selectivity of targeting. Development of an efficient molecular imaging agent depends on well-controlled high-quality experiment design involving target selection, agent synthesis, in vitro characterization, and in vivo animal characterization before it is applied in humans. According to the analysis from the Molecular Imaging and Contrast Agent Database (MICAD,
Hybrid optimal descriptors as a tool to predict skin sensitization in accordance to OECD principles.
Toropova, Alla P; Toropov, Andrey A
2017-06-05
Skin sensitization (allergic contact dermatitis) is a widespread problem arising from the contact of chemicals with the skin. The detection of molecular features with undesired effect for skin is complex task owing to unclear biochemical mechanisms and unclearness of conditions of action of chemicals to skin. The development of computational methods for estimation of this endpoint in order to reduce animal testing is recommended (Cosmetics Directive EC regulation 1907/2006; EU Regulation, Regulation, 1223/2009). The CORAL software (http://www.insilico.eu/coral) gives good predictive models for the skin sensitization. Simplified molecular input-line entry system (SMILES) together with molecular graph are used to represent the molecular structure for these models. So-called hybrid optimal descriptors are used to establish quantitative structure-activity relationships (QSARs). The aim of this study is the estimation of the predictive potential of the hybrid descriptors. Three different distributions into the training (≈70%), calibration (≈15%), and validation (≈15%) sets are studied. QSAR for these three distributions are built up with using the Monte Carlo technique. The statistical characteristics of these models for external validation set are used as a measure of predictive potential of these models. The best model, according to the above criterion, is characterized by n validation =29, r 2 validation =0.8596, RMSE validation =0.489. Mechanistic interpretation and domain of applicability for these models are defined. Copyright © 2017 Elsevier B.V. All rights reserved.
In vivo molecular photoacoustic tomography of melanomas targeted by bio-conjugated gold nanocages
Kim, Chulhong; Cho, Eun Chul; Chen, Jingyi; Song, Kwang Hyun; Au, Leslie; Favazza, Christopher; Zhang, Qiang; Cobley, Claire M.; Gao, Feng; Xia, Younan; Wang, Lihong V.
2010-01-01
Early diagnosis, accurate staging, and image-guided resection of melanomas remain crucial clinical objectives for improving patient survival and treatment outcomes. Conventional techniques cannot meet this demand because of the low sensitivity, low specificity, poor spatial resolution, shallow penetration, and/or ionizing radiation. Here we overcome such limitations by combining high-resolution photoacoustic tomography (PAT) with extraordinarily optical absorbing gold nanocages (AuNCs). When bio-conjugated with [Nle4,D-Phe7]-α-melanocyte-stimulating hormone, the AuNCs can serve as a novel contrast agent for in vivo molecular PAT of melanomas with both exquisite sensitivity and high specificity. The bio-conjugated AuNCs enhanced contrast ~300% more than the control, PEGylated AuNCs. The in vivo PAT quantification of the amount of AuNCs accumulated in melanomas was further validated with inductively coupled plasma mass spectrometry (ICP-MS). PMID:20731439
NASA Technical Reports Server (NTRS)
Ross, M. D.; Pote, K. G.; Rarey, K. E.; Verma, L. M.
1981-01-01
The gravity receptors of all vertebrates utilize a 'test mass' consisting of a complex arrangement of mineral and organic substance that lies over the sensory receptor areas. In most vertebrates, the mineral is a polymorph of calcium carbonate in the form of minute, single crystals called otoconia. An investigation is conducted to determine the number of proteins in otoconial complexes and their molecular weights. The investigation makes use of a microdisk gel electrophoresis method reported by Gainer (1971). The most important finding of the reported research is that analysis of the proteins of the organic material of the otoconial complexes is possible when sensitive microanalytical methods are employed. Further modification of the basic technique employed and the inclusion of other sensitive staining methods should mean that, in the future, protein separation by molecular weight will be possible in sample pools containing only two otoconial masses.
Methodological development of topographic correction in 2D/3D ToF-SIMS images using AFM images
NASA Astrophysics Data System (ADS)
Jung, Seokwon; Lee, Nodo; Choi, Myungshin; Lee, Jungmin; Cho, Eunkyunng; Joo, Minho
2018-02-01
Time-of-flight secondary-ion mass spectrometry (ToF-SIMS) is an emerging technique that provides chemical information directly from the surface of electronic materials, e.g. OLED and solar cell. It is very versatile and highly sensitive mass spectrometric technique that provides surface molecular information with their lateral distribution as a two-dimensional (2D) molecular image. Extending the usefulness of ToF-SIMS, a 3D molecular image can be generated by acquiring multiple 2D images in a stack. These imaging techniques by ToF-SIMS provide an insight into understanding the complex structures of unknown composition in electronic material. However, one drawback in ToF-SIMS is not able to represent topographical information in 2D and 3D mapping images. To overcome this technical limitation, topographic information by ex-situ technique such as atomic force microscopy (AFM) has been combined with chemical information from SIMS that provides both chemical and physical information in one image. The key to combine two different images obtained from ToF-SIMS and AFM techniques is to develop the image processing algorithm, which performs resize and alignment by comparing the specific pixel information of each image. In this work, we present methodological development of the semiautomatic alignment and the 3D structure interpolation system for the combination of 2D/3D images obtained by ToF-SIMS and AFM measurements, which allows providing useful analytical information in a single representation.
Probing molecular dynamics in solution with x-ray valence-to-core spectroscopy
NASA Astrophysics Data System (ADS)
Doumy, Gilles; March, Anne Marie; Tu, Ming-Feng; Al Haddad, Andre; Southworth, Stephen; Young, Linda; Walko, Donald; Bostedt, Christoph
2017-04-01
Hard X-ray spectroscopies are powerful tools for probing the electronic and geometric structure of molecules in complex or disordered systems and have been particularly useful for studying molecules in the solution phase. They are element specific, sensitive to the electronic structure and the local arrangements of surrounding atoms of the element being selectively probed. When combined in a pump-probe scheme with ultrafast lasers, X-ray spectroscopies can be used to track the evolution of structural changes that occur after photoexcitation. Efficient use of hard x-ray radiation coming from high brilliance synchrotrons and upcoming high repetition rate X-ray Free Electron Lasers requires MHz repetition rate lasers and data acquisition systems. High information content Valence-to-Core x-ray emission is directly sensitive to the molecular orbitals involved in photochemistry. We report on recent progress towards fully enabling this photon-hungry technique for the study of time-resolved molecular dynamics, including efficient detection and use of polychromatic x-ray micro-probe at the Advanced Photon Source. Work was supported by the U.S. Department of Energy, Office of Science, Chemical Sciences, Geosciences, and Biosciences Division.
NASA Technical Reports Server (NTRS)
Webster, C. R.
1985-01-01
A simple method is described for substantially reducing the amplitude of interference fringes that limit the sensitivities of tunable-laser high-resolution absorption spectrometers. A lead-salt diode laser operating in the 7-micron region is used with a single Brewster-plate spoiler to reduce the fringe amplitude by a factor of 30 and also to allow the detection of absorptances 0.001 percent in a single laser scan without subtraction techniques, without complex frequency modulation, and without distortion of the molecular line-shape signals. Application to multipass-cell spectrometers is described.
Biotechnical use of polymerase chain reaction for microbiological analysis of biological samples.
Lantz, P G; Abu al-Soud, W; Knutsson, R; Hahn-Hägerdal, B; Rådström, P
2000-01-01
Since its introduction in the mid-80s, polymerase chain reaction (PCR) technology has been recognised as a rapid, sensitive and specific molecular diagnostic tool for the analysis of micro-organisms in clinical, environmental and food samples. Although this technique can be extremely effective with pure solutions of nucleic acids, it's sensitivity may be reduced dramatically when applied directly to biological samples. This review describes PCR technology as a microbial detection method, PCR inhibitors in biological samples and various sample preparation techniques that can be used to facilitate PCR detection, by either separating the micro-organisms from PCR inhibitors and/or by concentrating the micro-organisms to detectable concentrations. Parts of this review are updated and based on a doctoral thesis by Lantz [1] and on a review discussing methods to overcome PCR inhibition in foods [2].
The utility of ductal lavage in breast cancer detection and risk assessment
Domchek, Susan M
2002-01-01
Ductal lavage (DL) permits noninvasive retrieval of epithelial cells from the breast. Clinical development of this technique has been fueled largely by its potential, as yet unproven, to improve detection of breast cancer and definition of individual risk for development of breast cancer. Early studies demonstrate the feasibility of performing this technique, provide data on cellular yield and findings, and demonstrate the ability to measure molecular markers in DL fluid. However, the sensitivity and specificity of DL for the detection of breast cancer remains unknown, as does the significance of atypia, particularly mild atypia, when found in DL fluid. Although DL appears safe and the device is approved by the US Food and Drug Administration, DL is still best utilized in the setting of clinical trials designed to resolve issues of sensitivity, specificity, and localization. PMID:11879562
Method and apparatus for enhancing laser absorption sensitivity
NASA Technical Reports Server (NTRS)
Webster, Christopher R. (Inventor)
1987-01-01
A simple optomechanical method and apparatus is described for substantially reducing the amplitude of unwanted multiple interference fringes which often limit the sensitivities of tunable laser absorption spectrometers. An exterior cavity is defined by partially transmissible surfaces such as a laser exit plate, a detector input, etc. That cavity is spoiled by placing an oscillating plate in the laser beam. For tunable diode laser spectroscopy in the mid-infrared region, a Brewster-plate spoiler allows the harmonic detection of absorptances of less than 10 to the -5 in a single laser scan. Improved operation is achieved without subtraction techniques, without complex laser frequency modulation, and without distortion of the molecular lineshape signal. The technique is applicable to tunable lasers operating from UV to IR wavelengths and in spectrometers which employ either short or long pathlengths, including the use of retroreflectors or multipass cells.
Plasmon Resonance Methods in GPCR Signaling and Other Membrane Events
Alves, I.D.; Park, C.K.; Hruby, V.J.
2005-01-01
The existence of surface guided electromagnetic waves has been theoretically predicted from Maxwell’s equations and investigated during the first decades of the 20th century. However, it is only since the late 1960’s that they have attracted the interest of surface physicists and earned the moniker of “surface plasmon”. With the advent of commercially available instruments and well established theories, the technique has been used to study a wide variety of biochemical and biotechnological phenomena. Spectral response of the resonance condition serves as a sensitive indicator of the optical properties of thin films immobilized within a wavelength of the surface. This enhanced surface sensitivity has provided a boon to the surface sciences, and fosters collaboration between surface chemistry, physics and the ongoing biological and biotechnological revolution. Since then, techniques based on surface plasmons such as Surface Plasmon Resonance (SPR), SPR Imaging, Plasmon Waveguide Resonance (PWR) and others, have been increasingly used to determine the affinity and kinetics of a wide variety of real time molecular interactions such as protein-protein, lipid-protein and ligand-protein, without the need for a molecular tag or label. The physical-chemical methodologies used to immobilize membranes at the surface of these optical devices are reviewed, pointing out advantages and limitations of each method. The paper serves to summarize both historical and more recent developments of these technologies for investigating structure-function aspects of these molecular interactions, and regulation of specific events in signal transduction by G-protein coupled receptors (GPCRs). PMID:16101432
Larenas-Linnemann, Désirée; Luna-Pech, Jorge A; Mösges, Ralph
2017-01-01
Percutaneous skin prick tests (SPT) have been considered the preferred method for confirming IgE-mediated sensitization. This reliable and minimally invasive technique correlates with in vivo challenges, has good reproducibility, is easily quantified, and allows analyzing multiple allergens simultaneously. Potent extracts and a proficient tester improve its accuracy. Molecular-based allergy diagnostics (MA-Dx) quantifies allergenic components obtained either from purification of natural sources or recombinant technology to identify the patient's reactivity to those specific allergenic protein components. For a correct allergy diagnosis, the patient selection is crucial. MA-Dx has been shown to have a high specificity, however, as MA-Dx testing can be ordered by any physician, the pre-selection of patients might not always be optimal, reducing test specificity. Also, MA-Dx is less sensitive than in vitro testing with the whole allergen or SPT. Secondly, no allergen-specific immunotherapy (AIT) trial has yet shown efficacy with patients selected on the basis of their MA-Dx results. Thirdly, why would we need molecular diagnosis, as no molecular treatment can yet be offered? Then there are the practical arguments of costs (SPT highly cost-efficient), test availability for MA-Dx still lacking in wide areas of the world and scarce in others. As such, it is hard physicians can build confidence in the test and their interpretation of the MA-Dx results. as of now these techniques should be reserved for situations of complex allergies and polysensitization; in the future MA-Dx might help to reduce the number of allergens for AIT, but trials are needed to prove this concept.
Davis, S C; Makarov, A A; Hughes, J D
1999-01-01
Analysis of sub-ppb levels of polynuclear aromatic hydrocarbons (PAHs) in drinking water by high performance liquid chromatography (HPLC) fluorescence detection typically requires large water samples and lengthy extraction procedures. The detection itself, although selective, does not give compound identity confirmation. Benchtop gas chromatography/mass spectrometry (GC/MS) systems operating in the more sensitive selected ion monitoring (SIM) acquisition mode discard spectral information and, when operating in scanning mode, are less sensitive and scan too slowly. The selectivity of hyperthermal surface ionisation (HSI), the high column flow rate capacity of the supersonic molecular beam (SMB) GC/MS interface, and the high acquisition rate of time-of-flight (TOF) mass analysis, are combined here to facilitate a rapid, specific and sensitive technique for the analysis of trace levels of PAHs in water. This work reports the advantages gained by using the GC/HSI-TOF system over the HPLC fluorescence method, and discusses in some detail the nature of the instrumentation used.
Ultrasensitive detection and characterization of molecules with infrared plasmonic metamaterials
Cheng, Fei; Yang, Xiaodong; Gao, Jie
2015-01-01
Infrared vibrational spectroscopy is an effective technique which enables the direct probe of molecular fingerprints, and such detection can be further enhanced by the emerging engineered plasmonic metamaterials. Here we experimentally demonstrate ultrasensitive detection and characterization of polymer molecules based on an asymmetric infrared plasmonic metamaterial, and quantitatively analyze the molecule detection sensitivity and molecule-structure interactions. A sharp, non-radiative Fano resonance supported by the plasmonic metamaterial exhibits strongly enhanced near-field, and the resonance frequency is tailored to match the vibrational fingerprint of the target molecule. By utilizing the near-field nature of the plasmonic excitation, significantly enhanced absorption signal of molecules in the infrared spectroscopy are obtained, enabling ultrasensitive detection of only minute quantities of organic molecules. The enhancement of molecular absorption up to 105 fold is obtained, and sensitive detection of molecules at zeptomole levels (corresponding to a few tens of molecules within a unit cell) is achieved with high signal-to-noise ratio in our experiment. The demonstrated infrared plasmonic metamaterial sensing platform offers great potential for improving the specificity and sensitivity of label-free, biochemical detection. PMID:26388404
Study of complex molecular systems by probe vibrational spectroscopy method
NASA Astrophysics Data System (ADS)
Boldeskul, A. E.; Zatsepin, V. M.; Atakhodjaev, A. K.; Shermatov, A. N.; Ashburiev, R.
1984-03-01
Experimental study of benzonitril as a probe in aqueous solution of sodium lauril sulphate /SDS/ by Raman spectroscopy technique showed integral moments of √ /C X N/ line to be extremely sensitive to the structural transitions in micellar systems. The central part of the experimental contour was used to determine integral moments with the help of line shape approximant received by Mori method
NASA Astrophysics Data System (ADS)
Ashby, Paul David
Investigation into the origin of forces dates to the early Greeks. Yet, only in recent decades have techniques for elucidating the molecular origin of forces been developed. Specifically, Chemical Force Microscopy uses the high precision and nanometer scale probe of Atomic Force Microscopy to measure molecular and interfacial interactions. This thesis presents the development of many novel Chemical Force Microscopy techniques for measuring equilibrium and time-dependant force profiles of molecular interactions, which led to a greater understanding of the origin of interfacial forces in solution. In chapter 2, Magnetic Feedback Chemical Force Microscopy stiffens the cantilever for measuring force profiles between self-assembled monolayer (SAM) surfaces. Hydroxyl and carboxyl terminated SAMs produce long-range interactions that extend one or three nanometers into the solvent, respectively. In chapter 3, an ultra low noise AFM is produced through multiple modifications to the optical deflection detection system and signal processing electronics. In chapter 4, Brownian Force Profile Reconstruction is developed for accurate measurement of steep attractive interactions. Molecular ordering is observed for OMCTS, 1-nonanol, and water near flat surfaces. The molecular ordering of the solvent produces structural or solvation forces, providing insight into the orientation and possible solidification of the confined solvent. Seven molecular layers of OMCTS are observed but the oil remains fluid to the last layer. 1-nonanol strongly orders near the surface and becomes quasi-crystalline with four layers. Water is oriented by the surface and symmetry requires two layers of water (3.7 A) to be removed simultaneously. In chapter 5, electronic control of the cantilever Q (Q-control) is used to obtain the highest imaging sensitivity. In chapter 6, Energy Dissipation Chemical Force Microscopy is developed to investigate the time dependence and dissipative characteristics of SAM interfacial interactions in solution. Long-range adhesive forces for hydroxyl and carboxyl terminated SAM surfaces arise from solvent, not ionic, interactions. Exclusion of the solvent and contact between the SAM surfaces leads to rearrangement of the SAM headgroups. The isolation of the chemical and physical interfacial properties from the topography by Energy Dissipation Chemical Force Microscopy produces a new quantitative high-sensitivity imaging mode.
Cherry, Simon R; Jones, Terry; Karp, Joel S; Qi, Jinyi; Moses, William W; Badawi, Ramsey D
2018-01-01
PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4-5 for imaging a single organ such as the brain or heart. The world's first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Preparation and coherent manipulation of pure quantum states of a single molecular ion
NASA Astrophysics Data System (ADS)
Chou, Chin-Wen; Kurz, Christoph; Hume, David B.; Plessow, Philipp N.; Leibrandt, David R.; Leibfried, Dietrich
2017-05-01
Laser cooling and trapping of atoms and atomic ions has led to advances including the observation of exotic phases of matter, the development of precision sensors and state-of-the-art atomic clocks. The same level of control in molecules could also lead to important developments such as controlled chemical reactions and sensitive probes of fundamental theories, but the vibrational and rotational degrees of freedom in molecules pose a challenge for controlling their quantum mechanical states. Here we use quantum-logic spectroscopy, which maps quantum information between two ion species, to prepare and non-destructively detect quantum mechanical states in molecular ions. We develop a general technique for optical pumping and preparation of the molecule into a pure initial state. This enables us to observe high-resolution spectra in a single ion (CaH+) and coherent phenomena such as Rabi flopping and Ramsey fringes. The protocol requires a single, far-off-resonant laser that is not specific to the molecule, so many other molecular ions, including polyatomic species, could be treated using the same methods in the same apparatus by changing the molecular source. Combined with the long interrogation times afforded by ion traps, a broad range of molecular ions could be studied with unprecedented control and precision. Our technique thus represents a critical step towards applications such as precision molecular spectroscopy, stringent tests of fundamental physics, quantum computing and precision control of molecular dynamics.
Preparation and coherent manipulation of pure quantum states of a single molecular ion.
Chou, Chin-Wen; Kurz, Christoph; Hume, David B; Plessow, Philipp N; Leibrandt, David R; Leibfried, Dietrich
2017-05-10
Laser cooling and trapping of atoms and atomic ions has led to advances including the observation of exotic phases of matter, the development of precision sensors and state-of-the-art atomic clocks. The same level of control in molecules could also lead to important developments such as controlled chemical reactions and sensitive probes of fundamental theories, but the vibrational and rotational degrees of freedom in molecules pose a challenge for controlling their quantum mechanical states. Here we use quantum-logic spectroscopy, which maps quantum information between two ion species, to prepare and non-destructively detect quantum mechanical states in molecular ions. We develop a general technique for optical pumping and preparation of the molecule into a pure initial state. This enables us to observe high-resolution spectra in a single ion (CaH + ) and coherent phenomena such as Rabi flopping and Ramsey fringes. The protocol requires a single, far-off-resonant laser that is not specific to the molecule, so many other molecular ions, including polyatomic species, could be treated using the same methods in the same apparatus by changing the molecular source. Combined with the long interrogation times afforded by ion traps, a broad range of molecular ions could be studied with unprecedented control and precision. Our technique thus represents a critical step towards applications such as precision molecular spectroscopy, stringent tests of fundamental physics, quantum computing and precision control of molecular dynamics.
Reis, Levi Eduardo Soares; Coura-Vital, Wendel; Roatt, Bruno Mendes; Bouillet, Leoneide Érica Maduro; Ker, Henrique Gama; Fortes de Brito, Rory Cristiane; Resende, Daniela de Melo; Carneiro, Mariângela; Giunchetti, Rodolfo Cordeiro; Marques, Marcos José; Carneiro, Cláudia Martins; Reis, Alexandre Barbosa
2013-11-08
Polymerase chain reaction (PCR) and its variations represent highly sensitive and specific methods for Leishmania DNA detection and subsequent canine visceral leishmaniasis (CVL) diagnosis. The aim of this work was to compare three different molecular diagnosis techniques (conventional PCR [cPCR], seminested PCR [snPCR], and quantitative PCR [qPCR]) in samples of skin and spleen from 60 seropositive dogs by immunofluorescence antibody test and enzyme-linked immunosorbent assay. Parasitological analysis was conducted by culture of bone marrow aspirate and optical microscopic assessment of ear skin and spleen samples stained with Giemsa, the standard tests for CVL diagnosis. The primers L150/L152 and LINR4/LIN17/LIN19 were used to amplify the conserved region of the Leishmania kDNA minicircle in the cPCR, and snPCR and qPCR were performed using the DNA polymerase gene (DNA pol α) primers from Leishmania infantum. The parasitological analysis revealed parasites in 61.7% of the samples. Sensitivities were 89.2%, 86.5%, and 97.3% in the skin and 81.1%, 94.6%, and 100.0% in spleen samples used for cPCR, snPCR, and qPCR, respectively. We demonstrated that the qPCR method was the best technique to detect L. infantum in both skin and spleen samples. However, we recommend the use of skin due to the high sensitivity and sampling being less invasive. Copyright © 2013 Elsevier B.V. All rights reserved.
Advances in serological, imaging techniques and molecular diagnosis of Toxoplasma gondii infection.
Rostami, Ali; Karanis, Panagiotis; Fallahi, Shirzad
2018-06-01
Toxoplasmosis is worldwide distributed zoonotic infection disease with medical importance in immunocompromised patients, pregnant women and congenitally infected newborns. Having basic information on the traditional and new developed methods is essential for general physicians and infectious disease specialists for choosing a suitable diagnostic approach for rapid and accurate diagnosis of the disease and, consequently, timely and effective treatment. We conducted English literature searches in PubMed from 1989 to 2016 using relevant keywords and summarized the recent advances in diagnosis of toxoplasmosis. Enzyme-linked immunosorbent assay (ELISA) was most used method in past century. Recently advanced ELISA-based methods including chemiluminescence assays (CLIA), enzyme-linked fluorescence assay (ELFA), immunochromatographic test (ICT), serum IgG avidity test and immunosorbent agglutination assays (ISAGA) have shown high sensitivity and specificity. Recent studies using recombinant or chimeric antigens and multiepitope peptides method demonstrated very promising results to development of new strategies capable of discriminating recently acquired infections from chronic infection. Real-time PCR and loop-mediated isothermal amplification (LAMP) are two recently developed PCR-based methods with high sensitivity and specificity and could be useful to early diagnosis of infection. Computed tomography, magnetic resonance imaging, nuclear imaging and ultrasonography could be useful, although their results might be not specific alone. This review provides a summary of recent developed methods and also attempts to improve their sensitivity for diagnosis of toxoplasmosis. Serology, molecular and imaging technologies each has their own advantages and limitations which can certainly achieve definitive diagnosis of toxoplasmosis by combining these diagnostic techniques.
Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression
NASA Astrophysics Data System (ADS)
Wong, Chak
2005-07-01
Explosives formulations with Reduced- Sensitivity RDX showed reduced shock sensitivity using NOL Large Scale Gap Test, compared with similar formulations using normal RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light to the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. SIRDX, a form of Reduced- Sensitivity RDX, was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transformed IR (FTIR). The pressure dependence of the Raman mode frequencies of SIRDX was determined and compared with that of normal RDX. The behavior of SIRDX near the pressure at which normal RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph will be presented. Implications to the reduction in sensitivity will be discussed.
NASA Astrophysics Data System (ADS)
Markus, Charles R.; McCollum, Jefferson E.; Hodges, James Neil; Perry, Adam J.; McCall, Benjamin J.
2017-06-01
Molecular ions are challenging to study with conventional spectroscopic methods. Laboratory discharges produce ions in trace quantities which can be obscured by the abundant neutral molecules present. The technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy (NICE-OHVMS) overcomes these challenges by combining the ion-neutral discrimination of velocity modulation spectroscopy with the sensitivity of Noise-Immune Cavity-Enhanced Optical Heterodyne Molecular Spectroscopy (NICE-OHMS), and has been able to determine transition frequencies of molecular ions in the mid-infrared (mid-IR) with sub-MHz uncertainties when calibrated with an optical frequency comb. However, the extent of these studies was limited by the presence of fringes due to parasitic etalons and the speed and noise characteristics of mid-IR detectors. Recently, we have overcome these limitations by implementing up-conversion detection and dithered optics. We performed up-conversion using periodically poled lithium niobate to convert light from the mid-IR to the visible to be within the coverage of sensitive and fast silicon detectors while maintaining our heterodyne and velocity modulation signals. The parasitic etalons were removed by rapidly rotating CaF_2 windows with galvanometers, which is known as a Brewster-plate spoiler, which averaged out the fringes in detection. Together, these improved the sensitivity by more than an order of magnitude and have enabled extended spectroscopic surveys of molecular ions in the mid-IR. J. N. Hodges, A. J. Perry, P. A. Jenkins II, B. M. Siller, and B. J. McCall, J. Chem. Phys. (2013), 139, 164201. C. R. Webster, J. Opt. Soc. Am. B (1985), 2, 1464. C. R. Markus, A. J. Perry, J. N. Hodges, and B. J. McCall, Opt. Express (2017), 25, 3709-3721.
Nicoś, M; Krawczyk, P; Wojas-Krawczyk, K; Bożyk, A; Jarosz, B; Sawicki, M; Trojanowski, T; Milanowski, J
2017-12-01
RT-PCR technique has showed a promising value as pre-screening method for detection of mRNA containing abnormal ALK sequences, but its sensitivity and specificity is still discussable. Previously, we determined the incidence of ALK rearrangement in CNS metastases of NSCLC using IHC and FISH methods. We evaluated ALK gene rearrangement using two-step RT-PCR method with EML4-ALK Fusion Gene Detection Kit (Entrogen, USA). The studied group included 145 patients (45 females, 100 males) with CNS metastases of NSCLC and was heterogeneous in terms of histology and smoking status. 21% of CNS metastases of NSCLC (30/145) showed presence of mRNA containing abnormal ALK sequences. FISH and IHC tests confirmed the presence of ALK gene rearrangement and expression of ALK abnormal protein in seven patients with positive result of RT-PCR analysis (4.8% of all patients, 20% of RT-PCR positive patients). RT-PCR method compared to FISH analysis achieved 100% of sensitivity and only 82.7% of specificity. IHC method compared to FISH method indicated 100% of sensitivity and 97.8% of specificity. In comparison to IHC, RT-PCR showed identical sensitivity with high number of false positive results. Utility of RT-PCR technique in screening of ALK abnormalities and in qualification patients for molecularly targeted therapies needs further validation.
Current Status and Future Perspectives of Mass Spectrometry Imaging
Nimesh, Surendra; Mohottalage, Susantha; Vincent, Renaud; Kumarathasan, Prem
2013-01-01
Mass spectrometry imaging is employed for mapping proteins, lipids and metabolites in biological tissues in a morphological context. Although initially developed as a tool for biomarker discovery by imaging the distribution of protein/peptide in tissue sections, the high sensitivity and molecular specificity of this technique have enabled its application to biomolecules, other than proteins, even in cells, latent finger prints and whole organisms. Relatively simple, with no requirement for labelling, homogenization, extraction or reconstitution, the technique has found a variety of applications in molecular biology, pathology, pharmacology and toxicology. By discriminating the spatial distribution of biomolecules in serial sections of tissues, biomarkers of lesions and the biological responses to stressors or diseases can be better understood in the context of structure and function. In this review, we have discussed the advances in the different aspects of mass spectrometry imaging processes, application towards different disciplines and relevance to the field of toxicology. PMID:23759983
Magnetic resonance microscopy: concepts, challenges, and state-of-the-art.
Gimi, Barjor
2006-01-01
Recent strides in targeted therapy and regenerative medicine have created a need to identify molecules and metabolic pathways implicated in a disease and its treatment. These molecules and pathways must be discerned at the cellular level to meaningfully reveal the biochemical underpinnings of the disease and to identify key molecular targets for therapy. Magnetic resonance (MR) techniques are well suited for molecular and functional imaging because of their noninvasive nature and their versatility in extracting physiological, biochemical, and functional information over time. However, MR is an insensitive technique; MR microscopy seeks to increase detection sensitivity, thereby localizing biochemical and functional information at the level of single cells or small cellular clusters. Here, we discuss some of the challenges facing MR microscopy and the technical and phenomenological strategies used to overcome these challenges. Some of the applications of MR microscopy are highlighted in this chapter.
NASA Technical Reports Server (NTRS)
Chin, G.; Buhl, D.; Florez, J. M.
1981-01-01
A survey of acousto-optic spectrometers for molecular astronomy is presented, noting a technique of combining the acoustic bending of a collimated coherent light beam with a Bragg cell followed by an array of sensitive photodetectors. This acousto-optic spectrometer has a large bandwidth, a large number of channels, high resolution, and is energy efficient. Receiver development has concentrated on high-frequency heterodyne systems for the study of the chemical composition of the interstellar medium. RF spectrometers employing acousto-optic diffraction cells are described. Acousto-optic techniques have been suggested for applications to electronic warfare, electronic countermeasures and electronic support systems. Plans to use integrated optics for the further miniaturization of acousto-optic spectrometers are described. Bulk acousto-optic spectrometers with 300 MHz and 1 GHz bandwidths are being developed for use in the back-end of high-frequency heterodyne receivers for astronomical research.
Raman Spectroscopy of Microbial Pigments
Edwards, Howell G. M.; Oren, Aharon
2014-01-01
Raman spectroscopy is a rapid nondestructive technique providing spectroscopic and structural information on both organic and inorganic molecular compounds. Extensive applications for the method in the characterization of pigments have been found. Due to the high sensitivity of Raman spectroscopy for the detection of chlorophylls, carotenoids, scytonemin, and a range of other pigments found in the microbial world, it is an excellent technique to monitor the presence of such pigments, both in pure cultures and in environmental samples. Miniaturized portable handheld instruments are available; these instruments can be used to detect pigments in microbiological samples of different types and origins under field conditions. PMID:24682303
Fang, Cheng; Wang, Kun; Zeng, Chaoting; Chi, Chongwei; Shang, Wenting; Ye, Jinzuo; Mao, Yamin; Fan, Yingfang; Yang, Jian; Xiang, Nan; Zeng, Ning; Zhu, Wen; Fang, Chihua; Tian, Jie
2016-01-01
Tissue necrosis commonly accompanies the development of a wide range of serious diseases. Therefore, highly sensitive detection and precise boundary delineation of necrotic tissue via effective imaging techniques are crucial for clinical treatments; however, no imaging modalities have achieved satisfactory results to date. Although fluorescence molecular imaging (FMI) shows potential in this regard, no effective necrosis-avid fluorescent probe has been developed for clinical applications. Here, we demonstrate that indocyanine green (ICG) can achieve high avidity of necrotic tissue owing to its interaction with lipoprotein (LP) and phospholipids. The mechanism was explored at the cellular and molecular levels through a series of in vitro studies. Detection of necrotic tissue and real-time image-guided surgery were successfully achieved in different organs of different animal models with the help of FMI using in house-designed imaging devices. The results indicated that necrotic tissue with a 0.6 mm diameter could be effectively detected with precise boundary definition. We believe that the new discovery and the associated imaging techniques will improve personalized and precise surgery in the near future. PMID:26864116
Molecular-Scale Investigation of Heavy Metal Ions at a Charged Langmuir Monolayer
NASA Astrophysics Data System (ADS)
Rock, William; Qiao, Baofu; Uysal, Ahmet; Bu, Wei; Lin, Binhua
Solvent extraction - the surfactant-aided preferential transfer of a species from an aqueous to an organic phase - is an important technique used in heavy and precious metal refining and reprocessing. Solvent extraction requires transfer through an oil/water interface, and interfacial interactions are expected to control transfer kinetics and phase stability, yet these key interactions are poorly understood. Langmuir monolayers with charged headgroups atop concentrated salt solutions containing heavy metal ions act as a model of solvent extraction interfaces; studies of ions at a charged surface are also fundamentally important to many other phenomena including protein solvation, mineral surface chemistry, and electrochemistry. We probe these charged interfaces using a variety of surface-sensitive techniques - vibrational sum frequency generation (VSFG) spectroscopy, x-ray reflectivity (XRR), x-ray fluorescence near total reflection (XFNTR), and grazing incidence diffraction (GID). We integrate experiments with Molecular Dynamics (MD) simulations to uncover the molecular-level interfacial structure. This work is supported by the U.S. DOE, BES, Contract DE-AC02-06CH11357. ChemMatCARS is supported by NSF/CHE-1346572.
Cho, Yunjo; Jin, Jang Mi; Witt, Matthias; Birdwell, Justin E.; Na, Jeong-Geol; Roh, Nam-Sun; Kim, Sunghwan
2013-01-01
Laser desorption ionization (LDI) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was used to analyze shale oils. Previous work showed that LDI is a sensitive ionization technique for assessing aromatic nitrogen compounds, and oils generated from Green River Formation oil shales are well-documented as being rich in nitrogen. The data presented here demonstrate that LDI is effective in ionizing high-double-bond-equivalent (DBE) compounds and, therefore, is a suitable method for characterizing compounds with condensed structures. Additionally, LDI generates radical cations and protonated ions concurrently, the distribution of which depends upon the molecular structures and elemental compositions, and the basicity of compounds is closely related to the generation of protonated ions. This study demonstrates that LDI FT-ICR MS is an effective ionization technique for use in the study of shale oils at the molecular level. To the best of our knowledge, this is the first time that LDI FT-ICR MS has been applied to shale oils.
Multiple Myeloma Minimal Residual Disease.
Paiva, Bruno; García-Sanz, Ramón; San Miguel, Jesús F
Assessment of minimal residual disease (MRD) is becoming standard diagnostic care for potentially curable neoplasms such as some acute leukemias as well as chronic myeloid and lymphocytic leukemia. Although multiple myeloma (MM) remains as an incurable disease, around half of the patients achieve complete remission (CR), and recent data suggests increasing rates of curability with "total-therapy-like" programs. This landscape is likely to be improved with the advent of new antibodies and small molecules. Therefore, conventional serological and morphological techniques have become suboptimal for sensitive evaluation of highly effective treatment strategies. Although, existing data suggests that MRD could be used as a biomarker to evaluate treatment efficacy, help on therapeutic decisions, and act as surrogate for overall survival, the role of MRD in MM is still a matter of extensive debate. Here, we review the different levels of remission used to define depth of response in MM and their clinical significance, as well as the prognostic value and unique characteristics of MRD detection using immunophenotypic, molecular, and imaging techniques. Key facts The higher efficacy of new treatment strategies for MM demand the incorporation of highly sensitive techniques to monitor treatment efficacy MRD could be used as a more potent surrogate biomarker for survival than standard CR We need to understand the pros and cons of the different MRD techniques The time has come to incorporate highly sensitive, cost-effective, readily available, and standardized MRD techniques into clinical trials to assess its role in therapeutic decisions.
Fiber sensors for molecular detection
NASA Astrophysics Data System (ADS)
Gu, Claire; Yang, Xuan; Zhang, Jin; Newhouse, Rebecca; Cao, Liangcai
2010-11-01
The demand on sensors for detecting chemical and biological agents is greater than ever before, including medical, environmental, food safety, military, and security applications. At present, most detection or sensing techniques tend to be either non-molecular specific, bulky, expensive, relatively inaccurate, or unable to provide real time data. Clearly, alternative sensing technologies are urgently needed. Recently, we have been working to develop a compact fiber optic surface enhanced Raman scattering (SERS) sensor system that integrates various novel ideas to achieve compactness, high sensitivity and consistency, molecular specificity, and automatic preliminary identification capabilities. The unique sensor architecture is expected to bring SERS sensors to practical applications due to a combination of 1) novel SERS substrates that provide the high sensitivity and consistency, molecular specificity, and applicability to a wide range of compounds; 2) a unique hollow core optical fiber probe with double SERS substrate structure that provides the compactness, reliability, low cost, and ease of sampling; and 3) an innovative matched spectral filter set that provides automatic preliminary molecule identification. In this paper, we will review the principle of operation and some of the important milestones of fiber SERS sensor development with emphasis on our recent work to integrate photonic crystal fiber SERS probes with a portable Raman spectrometer and to demonstrate a matched spectral filter for molecule identification.
Borrini, Francesco; Bolognese, Antonio; Lamy, Aude; Sabourin, Jean-Christophe
2015-01-01
KRAS genotyping is mandatory in metastatic colorectal cancer treatment prior to undertaking antiepidermal growth factor receptor (EGFR) monoclonal antibody therapy. BRAF V600E mutation is often present in colorectal carcinoma with CpG island methylator phenotype and microsatellite instability. Currently, KRAS and BRAF evaluation is based on molecular biology techniques such as SNaPshot or Sanger sequencing. As molecular testing is performed on formalin-fixed paraffin-embedded (FFPE) samples, immunodetection would appear to be an attractive alternative for detecting mutations. Thus, our objective was to assess the validity of KRAS and BRAF immunodetection of mutations compared with the genotyping reference method in colorectal adenocarcinoma. KRAS and BRAF genotyping was assessed by SNaPshot. A rabbit anti-human KRAS polyclonal antibody was tested on 33 FFPE colorectal tumor samples with known KRAS status. Additionally, a mouse anti-human BRAF monoclonal antibody was tested on 30 FFPE tumor samples with known BRAF status. KRAS immunostaining demonstrated both poor sensitivity (27%) and specificity (64%) in detecting KRAS mutation. Conversely, BRAF immunohistochemistry showed perfect sensitivity (100%) and specificity (100%) in detecting V600E mutation. Although molecular biology remains the reference method for detecting KRAS mutation, immunohistochemistry could be an attractive method for detecting BRAF V600E mutation in colorectal cancer. PMID:25983749
Combined photoacoustic and magneto-acoustic imaging.
Qu, Min; Mallidi, Srivalleesha; Mehrmohammadi, Mohammad; Ma, Li Leo; Johnston, Keith P; Sokolov, Konstantin; Emelianov, Stanislav
2009-01-01
Ultrasound is a widely used modality with excellent spatial resolution, low cost, portability, reliability and safety. In clinical practice and in the biomedical field, molecular ultrasound-based imaging techniques are desired to visualize tissue pathologies, such as cancer. In this paper, we present an advanced imaging technique - combined photoacoustic and magneto-acoustic imaging - capable of visualizing the anatomical, functional and biomechanical properties of tissues or organs. The experiments to test the combined imaging technique were performed using dual, nanoparticle-based contrast agents that exhibit the desired optical and magnetic properties. The results of our study demonstrate the feasibility of the combined photoacoustic and magneto-acoustic imaging that takes the advantages of each imaging techniques and provides high sensitivity, reliable contrast and good penetrating depth. Therefore, the developed imaging technique can be used in wide range of biomedical and clinical application.
Bench-to-bedside review: Rapid molecular diagnostics for bloodstream infection - a new frontier?
2012-01-01
Among critically ill patients, the diagnosis of bloodstream infection poses a major challenge. Current standard bacterial identification based on blood culture platforms is intrinsically time-consuming and slow. The continuous evolvement of molecular techniques has the potential of providing a faster, more sensitive and direct identification of causative pathogens without prior need for cultivation. This may ultimately impact clinical decision-making and antimicrobial treatment. This review summarises the currently available technologies, their strengths and limitations and the obstacles that have to be overcome in order to develop a satisfactory bedside point-of-care diagnostic tool for detection of bloodstream infection. PMID:22647543
Circulating Cell-Free Tumour DNA in the Management of Cancer
Francis, Glenn; Stein, Sandra
2015-01-01
With the development of new sensitive molecular techniques, circulating cell-free tumour DNA containing mutations can be identified in the plasma of cancer patients. The applications of this technology may result in significant changes to the care and management of cancer patients. Whilst, currently, these “liquid biopsies” are used to supplement the histological diagnosis of cancer and metastatic disease, in the future these assays may replace the need for invasive procedures. Applications include the monitoring of tumour burden, the monitoring of minimal residual disease, monitoring of tumour heterogeneity, monitoring of molecular resistance and early diagnosis of tumours and metastatic disease. PMID:26101870
NASA Technical Reports Server (NTRS)
Albyn, Keith; Burns, Dewitt
2006-01-01
Recent quartz crystal microbalance measurements made in the Marshall Space Flight Center, Photo-Deposition Facility, for several materials, recorded a significant loss of deposited contaminants when the deposition surface of the microbalance was illuminated by a deuterium lamp. These measurements differ from observations made by other investigators in which the rate of deposition increased significantly when the deposition surface was illuminated with vacuum ultraviolet radiation. These observations suggest that the accelerated deposition of molecular contaminants on optically sensitive surfaces is dependant upon the contaminant being deposited and must be addressed during the materials selection process by common material screening techniques.
NASA Astrophysics Data System (ADS)
Wren, Stephen P.; Piletsky, Sergey A.; Karim, Kal; Gascoine, Paul; Lacey, Richard; Sun, Tong; Grattan, Kenneth T. V.
2014-05-01
Previously, we have developed chemical sensors using fibre optic-based techniques for the detection of Cocaine, utilising molecularly imprinted polymers (MIPs) containing fluorescein moieties as the signalling groups. Here, we report the computational design of a fluorophore which was incorporated into a MIP for the generation of a novel sensor that offers improved sensitivity for Cocaine with a detection range of 1-100μM. High selectivity for Cocaine over a suite of known Cocaine interferants (25μM) was also demonstrated by measuring changes in the intensity of fluorescence signals received from the sensor.
Sensitive molecular diagnostics using surface-enhanced resonance Raman scattering (SERRS)
NASA Astrophysics Data System (ADS)
Faulds, Karen; Graham, Duncan; McKenzie, Fiona; MacRae, Douglas; Ricketts, Alastair; Dougan, Jennifer
2009-02-01
Surface enhanced resonance Raman scattering (SERRS) is an analytical technique with several advantages over competitive techniques in terms of improved sensitivity and multiplexing. We have made great progress in the development of SERRS as a quantitative analytical method, in particular for the detection of DNA. SERRS is an extremely sensitive and selective technique which when applied to the detection of labelled DNA sequences allows detection limits to be obtained which rival, and in most cases, are better than fluorescence. Here the conditions are explored which will enable the successful detection of DNA using SERRS. The enhancing surface which is used is crucial and in this case suspensions of nanoparticles were used as they allow quantitative behaviour to be achieved and allow analogous systems to current fluorescence based systems to be made. The aggregation conditions required to obtain SERRS of DNA are crucial and herein we describe the use of spermine as an aggregating agent. The nature of the label which is used, be it fluorescent, positively or negatively charged also effects the SERRS response and these conditions are again explored here. We have clearly demonstrated the ability to identify the components of a mixture of 5 analytes in solution by using two different excitation wavelengths and also of a 6-plex using data analysis techniques. These conditions will allow the use of SERRS for the detection of target DNA in a meaningful diagnostic assay.
Molecular epidemiology for vector research on leishmaniasis.
Kato, Hirotomo; Gomez, Eduardo A; Cáceres, Abraham G; Uezato, Hiroshi; Mimori, Tatsuyuki; Hashiguchi, Yoshihisa
2010-03-01
Leishmaniasis is a protozoan disease caused by the genus Leishmania transmitted by female phlebotomine sand flies. Surveillance of the prevalence of Leishmania and responsive vector species in endemic and surrounding areas is important for predicting the risk and expansion of the disease. Molecular biological methods are now widely applied to epidemiological studies of infectious diseases including leishmaniasis. These techniques are used to detect natural infections of sand fly vectors with Leishmania protozoa and are becoming powerful tools due to their sensitivity and specificity. Recently, genetic analyses have been performed on sand fly species and genotyping using PCR-RFLP has been applied to the sand fly taxonomy. In addition, a molecular mass screening method has been established that enables both sand fly species and natural leishmanial infections to be identified simultaneously in hundreds of sand flies with limited effort. This paper reviews recent advances in the study of sand flies, vectors of leishmaniasis, using molecular biological approaches.
Myjak, P; Majewska, A C; Bajer, A; Siński, E; Wedrychowicz, H; Gołab, E; Budak, A; Stańczak, J
2001-01-01
After a long period of using basic microscopic, immunological and biochemical methods for diagnosis, rapid development of nucleic acids investigation enabled introduction of specific and sensitive methods of detection of pathogenic agents on the molecular level. Among others, polymerase chain reaction (PCR), discovered in mid of 80'ies and then automatized, offered an attractive alternative to conventional testing systems. In this paper we describe reliable diagnostic tests widely used in the world, including Poland, and capable of detecting different disease agents as parasites and fungi in clinical specimens and pathogens of emerging zoonotic diseases in ticks. The possibilities of using molecular methods for determination of Plasmodium falciparum drug resistance is also discussed. Moreover, the report offers information concerning kinds of molecular tests and institutions in which there are executed.
Molecular Epidemiology for Vector Research on Leishmaniasis
Kato, Hirotomo; Gomez, Eduardo A; Cáceres, Abraham G; Uezato, Hiroshi; Mimori, Tatsuyuki; Hashiguchi, Yoshihisa
2010-01-01
Leishmaniasis is a protozoan disease caused by the genus Leishmania transmitted by female phlebotomine sand flies. Surveillance of the prevalence of Leishmania and responsive vector species in endemic and surrounding areas is important for predicting the risk and expansion of the disease. Molecular biological methods are now widely applied to epidemiological studies of infectious diseases including leishmaniasis. These techniques are used to detect natural infections of sand fly vectors with Leishmania protozoa and are becoming powerful tools due to their sensitivity and specificity. Recently, genetic analyses have been performed on sand fly species and genotyping using PCR-RFLP has been applied to the sand fly taxonomy. In addition, a molecular mass screening method has been established that enables both sand fly species and natural leishmanial infections to be identified simultaneously in hundreds of sand flies with limited effort. This paper reviews recent advances in the study of sand flies, vectors of leishmaniasis, using molecular biological approaches. PMID:20617005
In vivo nanoparticle-mediated radiopharmaceutical-excited fluorescence molecular imaging
Hu, Zhenhua; Qu, Yawei; Wang, Kun; Zhang, Xiaojun; Zha, Jiali; Song, Tianming; Bao, Chengpeng; Liu, Haixiao; Wang, Zhongliang; Wang, Jing; Liu, Zhongyu; Liu, Haifeng; Tian, Jie
2015-01-01
Cerenkov luminescence imaging utilizes visible photons emitted from radiopharmaceuticals to achieve in vivo optical molecular-derived signals. Since Cerenkov radiation is weak, non-optimum for tissue penetration and continuous regardless of biological interactions, it is challenging to detect this signal with a diagnostic dose. Therefore, it is challenging to achieve useful activated optical imaging for the acquisition of direct molecular information. Here we introduce a novel imaging strategy, which converts γ and Cerenkov radiation from radioisotopes into fluorescence through europium oxide nanoparticles. After a series of imaging studies, we demonstrate that this approach provides strong optical signals with high signal-to-background ratios, an ideal tissue penetration spectrum and activatable imaging ability. In comparison with present imaging techniques, it detects tumour lesions with low radioactive tracer uptake or small tumour lesions more effectively. We believe it will facilitate the development of nuclear and optical molecular imaging for new, highly sensitive imaging applications. PMID:26123615
NASA Astrophysics Data System (ADS)
Skala, Melissa C.; Crow, Matthew J.; Wax, Adam; Izatt, Joseph A.
2009-02-01
Molecular imaging is a powerful tool for investigating disease processes and potential therapies in both in vivo and in vitro systems. However, high resolution molecular imaging has been limited to relatively shallow penetration depths that can be accessed with microscopy. Optical coherence tomography (OCT) is an optical analogue to ultrasound with relatively good penetration depth (1-2 mm) and resolution (~1-10 μm). We have developed and characterized photothermal OCT as a molecular contrast mechanism that allows for high resolution molecular imaging at deeper penetration depths than microscopy. Our photothermal system consists of an amplitude-modulated heating beam that spatially overlaps with the focused spot of the sample arm of a spectral-domain OCT microscope. Validation experiments in tissue-like phantoms containing gold nanospheres that absorb at 532 nm revealed a sensitivity of 14 parts per million nanospheres (weight/weight) in a tissue-like environment. The nanospheres were then conjugated to anti-EGFR, and molecular targeting was confirmed in cells that over-express EGFR (MDA-MB-468) and cells that express low levels of EGFR (MDA-MB-435). Molecular imaging in three-dimensional tissue constructs was confirmed with a significantly lower photothermal signal (p<0.0001) from the constructs composed of cells that express low levels of EGFR compared to the over-expressing cell constructs (300% signal increase). This technique could potentially augment confocal and multiphoton microscopy as a method for deep-tissue, depth-resolved molecular imaging with relatively high resolution and target sensitivity, without photobleaching or cytotoxicity.
Kühnemund, Malte; Hernández-Neuta, Iván; Sharif, Mohd Istiaq; Cornaglia, Matteo; Gijs, Martin A M; Nilsson, Mats
2017-05-05
Single molecule quantification assays provide the ultimate sensitivity and precision for molecular analysis. However, most digital analysis techniques, i.e. droplet PCR, require sophisticated and expensive instrumentation for molecule compartmentalization, amplification and analysis. Rolling circle amplification (RCA) provides a simpler means for digital analysis. Nevertheless, the sensitivity of RCA assays has until now been limited by inefficient detection methods. We have developed a simple microfluidic strategy for enrichment of RCA products into a single field of view of a low magnification fluorescent sensor, enabling ultra-sensitive digital quantification of nucleic acids over a dynamic range from 1.2 aM to 190 fM. We prove the broad applicability of our analysis platform by demonstrating 5-plex detection of as little as ∼1 pg (∼300 genome copies) of pathogenic DNA with simultaneous antibiotic resistance marker detection, and the analysis of rare oncogene mutations. Our method is simpler, more cost-effective and faster than other digital analysis techniques and provides the means to implement digital analysis in any laboratory equipped with a standard fluorescent microscope. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.
Ackerman, L K; Noonan, G O; Begley, T H
2009-12-01
The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.
NASA Astrophysics Data System (ADS)
Yu, Ping; Ma, Lixin
2012-02-01
In this work we developed two biomedical imaging techniques for early detection of breast cancer. Both image modalities provide molecular imaging capability to probe site-specific targeting dyes. The first technique, heterodyne CCD fluorescence mediated tomography, is a non-invasive biomedical imaging that uses fluorescent photons from the targeted dye on the tumor cells inside human breast tissue. The technique detects a large volume of tissue (20 cm) with a moderate resolution (1 mm) and provides the high sensitivity. The second technique, dual-band spectral-domain optical coherence tomography, is a high-resolution tissue imaging modality. It uses a low coherence interferometer to detect coherent photons hidden in the incoherent background. Due to the coherence detection, a high resolution (20 microns) is possible. We have finished prototype imaging systems for the development of both image modalities and performed imaging experiments on tumor tissues. The spectroscopic/tomographic images show contrasts of dense tumor tissues and tumor necrotic regions. In order to correlate the findings from our results, a diffusion-weighted magnetic resonance imaging (MRI) of the tumors was performed using a small animal 7-Telsa MRI and demonstrated excellent agreement.
Resonant Soft X-ray Scattering as a Powerful Probe of Buried Polymer Interfaces
NASA Astrophysics Data System (ADS)
Chen, Wei; Jiang, Zhang; Tirrell, Matthew
Elucidation of polymer interfacial structures provides insights into interfacial molecular mechanisms for coating protection, adhesion, lubrication, friction, wettability, biocompatibility, and even charge transport properties. Resonant Soft X-ray Scattering (RSoXS) offers a unique element, site and valence specific probe to study spatial modulations of molecular orbital degrees of freedom on the nanoscopic length scale. This unique sensitivity is achieved by merging small angle x-ray scattering and x-ray absorption spectroscopy into a single experiment, where the scattering provides information about spatial modulations and the spectroscopy provides sensitivity to the molecular anisotropy. Here we applied RSoXS to polystyrene (PS) films at solid-solid interfaces and poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) brushes at solid-liquid interfaces. It is found that the interfacial width of PS thin film is about one order of magnitude large than those observed by traditional scattering techniques. In addition, although the ion-induced changes of PMPC thickness are not apparent in aqueous solutions, their chain conformations like polyzwitterion distribution and correlation varied, dependent on salt types, ionic strengths and ion valences. Consequently, it is evident that RSoXS is a powerful probe of buried polymer interlaces with both spatial and chemical sensitivities. This work was supported by the U.S. Department of Energy, Office of Science, Program in Basic Energy Sciences, Division of Materials Science and Engineering.
Molecular interferometric imaging study of molecular interactions
NASA Astrophysics Data System (ADS)
Zhao, Ming; Wang, Xuefeng; Nolte, David
2008-02-01
Molecular Interferometric Imaging (MI2) is a sensitive detection platform for direct optical detection of immobilized biomolecules. It is based on inline common-path interferometry combined with far-field optical imaging. The substrate is a simple thermal oxide on a silicon surface with a thickness at or near the quadrature condition that produces a π/2 phase shift between the normal-incident wave reflected from the top oxide surface and the bottom silicon surface. The presence of immobilized or bound biomolecules on the surface produces a relative phase shift that is converted to a far-field intensity shift and is imaged by a reflective microscope onto a CCD camera. Shearing interferometry is used to remove the spatial 1/f noise from the illumination to achieve shot-noise-limited detection of surface dipole density profiles. The lateral resolution of this technique is diffraction limited at 0.4 micron, and the best longitudinal resolution is 10 picometers. The minimum detectable mass at the metrology limit is 2 attogram, which is 8 antibody molecules of size 150 kDa. The corresponding scaling mass sensitivity is 5 fg/mm compared with 1 pg/mm for typical SPR sensitivity. We have applied MI2 to immunoassay applications, and real-time binding kinetics has been measured for antibody-antigen reactions. The simplicity of the substrate and optical read-out make MI2 a promising analytical assay tool for high-throughput screening and diagnostics.
European Science Notes Information Bulletin Reports on Current European/ Middle Eastern Science
1988-07-01
41 Recently concluded and planned experiments are described which arc based on static Kerr effect dis- persion- spectroscopy , optical Kerr effect...studies, and both electric and magnetic resonance 6 molecular beam spectroscopy . These advanced techniques are used to measure with great precision...simuhItio , using thrcc-dimcn- flight using temperature-sensitive films and infrared sional singularities in a panel ncthod. camecras placed on either side
2012-07-01
use of molecular biological techniques (MBTs) has allowed microbial ecologists and environmental engineers to determine microbial community...metabolic genes). The most common approaches used in bioremediation research are those based on the polymerase chain reaction (PCR) amplification of... bioremediation . Because of its sensitivity compared to direct hybridization/probing, PCR is increasingly used to analyze groundwater samples and soil samples
Kokosková, B; Mráz, I; Fousek, J
2010-05-01
Detection of Clavibacter michiganensis subsp. michiganensis (Cmm), causing bacterial canker of tomato, was verified using PTA-ELISA and IFAS with PAbs of Neogen Europe Ltd. (UK), and with published and also laboratory-generated PCR primers from the Cmm tomatinase gene. The specificity of this technique was determined with 15 plant-pathogenic and 4 common, saprophytic bacteria. With IFAS, crossreactions were found for Pantoea dispersa, P. agglomerans and Rahnella aquatilis, and with PTA-ELISA for Curtobacterium flaccumfaciens, Pectobacterium atrosepticum and Dickeya sp. Cross-reactions with subspecies other than michiganensis were also found using both methods. Molecular methods were optimized by verification of annealing temperatures and times for both primers. Conditions were finally adjusted to 30 s at 65 degrees C for Dreier's and 10 s at 69 degrees C for our primer set. After this optimization, both primer pairs produced positive reaction only with Cmm. By means of PTA-ELISA and IFAS, Cmm strains were detected at a concentration up to 10(5) CFU/mL and 10(3) CFU/mL, respectively. The PCR test with bacterial cell suspensions reached a sensitivity of 10(3) CFU/mL with our designed primers and 104 CFU/mL with Dreier's primer pair.
A Protein Nanopore-Based Approach for Bacteria Sensing
NASA Astrophysics Data System (ADS)
Apetrei, Aurelia; Ciuca, Andrei; Lee, Jong-kook; Seo, Chang Ho; Park, Yoonkyung; Luchian, Tudor
2016-11-01
We present herein a first proof of concept demonstrating the potential of a protein nanopore-based technique for real-time detection of selected Gram-negative bacteria ( Pseudomonas aeruginosa or Escherichia coli) at a concentration of 1.2 × 108 cfu/mL. The anionic charge on the bacterial outer membrane promotes the electrophoretically driven migration of bacteria towards a single α-hemolysin nanopore isolated in a lipid bilayer, clamped at a negative electric potential, and followed by capture at the nanopore's mouth, which we found to be described according to the classical Kramers' theory. By using a specific antimicrobial peptide as a putative molecular biorecognition element for the bacteria used herein, we suggest that the detection system can combine the natural sensitivity of the nanopore-based sensing techniques with selective biological recognition, in aqueous samples, and highlight the feasibility of the nanopore-based platform to provide portable, sensitive analysis and monitoring of bacterial pathogens.
Cavity-Enhanced Absorption Spectroscopy and Photoacoustic Spectroscopy for Human Breath Analysis
NASA Astrophysics Data System (ADS)
Wojtas, J.; Tittel, F. K.; Stacewicz, T.; Bielecki, Z.; Lewicki, R.; Mikolajczyk, J.; Nowakowski, M.; Szabra, D.; Stefanski, P.; Tarka, J.
2014-12-01
This paper describes two different optoelectronic detection techniques: cavity-enhanced absorption spectroscopy and photoacoustic spectroscopy. These techniques are designed to perform a sensitive analysis of trace gas species in exhaled human breath for medical applications. With such systems, the detection of pathogenic changes at the molecular level can be achieved. The presence of certain gases (biomarkers), at increased concentration levels, indicates numerous human diseases. Diagnosis of a disease in its early stage would significantly increase chances for effective therapy. Non-invasive, real-time measurements, and high sensitivity and selectivity, capable of minimum discomfort for patients, are the main advantages of human breath analysis. At present, monitoring of volatile biomarkers in breath is commonly useful for diagnostic screening, treatment for specific conditions, therapy monitoring, control of exogenous gases (such as bacterial and poisonous emissions), as well as for analysis of metabolic gases.
Mwingira, Felista; Genton, Blaise; Kabanywanyi, Abdu-Noor M; Felger, Ingrid
2014-11-18
The use of molecular techniques to detect malaria parasites has been advocated to improve the accuracy of parasite prevalence estimates, especially in moderate to low endemic settings. Molecular work is time-consuming and costly, thus the effective gains of this technique need to be carefully evaluated. Light microscopy (LM) and rapid diagnostic tests (RDT) are commonly used to detect malaria infection in resource constrained areas, but their limited sensitivity results in underestimation of the proportion of people infected with Plasmodium falciparum. This study aimed to evaluate the extent of missed infections via a community survey in Tanzania, using polymerase chain reaction (PCR) to detect P. falciparum parasites and gametocytes. Three hundred and thirty individuals of all ages from the Kilombero and Ulanga districts (Tanzania) were enrolled in a cross-sectional survey. Finger prick blood samples were collected for parasite detection by RDT, LM and molecular diagnosis using quantitative 18S rRNA PCR and msp2 nPCR. Gametocytes were detected by LM and by amplifying transcripts of the gametocyte-specific marker pfs25. Results from all three diagnostic methods were available for a subset of 226 individuals. Prevalence of P. falciparum was 38% (86/226; 95% CI 31.9-44.4%) by qPCR, 15.9% (36/226; 95% CI 11.1-20.7%) by RDT and 5.8% (13/226; 95% CI 2.69- 8.81%) by LM. qPCR was positive for 72% (26/36) of the RDT-positive samples. Gametocyte prevalence was 10.6% (24/226) by pfs25-qRT-PCR and 1.2% by LM. LM showed the poorest performance, detecting only 15% of P. falciparum parasite carriers identified by PCR. Thus, LM is not a sufficiently accurate technique from which to inform policies and malaria control or elimination efforts. The diagnostic performance of RDT was superior to that of LM. However, it is also insufficient when precise prevalence data are needed for monitoring intervention success or for determining point prevalence rates in countrywide surveillance. Detection of gametocytes by PCR was 10-times more sensitive than by LM. These findings support the need for molecular techniques to accurately estimate the human infectious reservoir and hence the transmission potential in a population.
Molecular imaging in neuroendocrine tumors: molecular uptake mechanisms and clinical results.
Koopmans, Klaas P; Neels, Oliver N; Kema, Ido P; Elsinga, Philip H; Links, Thera P; de Vries, Elisabeth G E; Jager, Pieter L
2009-09-01
Neuroendocrine tumors can originate almost everywhere in the body and consist of a great variety of subtypes. This paper focuses on molecular imaging methods using nuclear medicine techniques in neuroendocrine tumors, coupling molecular uptake mechanisms of radiotracers with clinical results. A non-systematic review is presented on receptor based and metabolic imaging methods. Receptor-based imaging covers the molecular backgrounds of somatostatin, vaso-intestinal peptide (VIP), bombesin and cholecystokinin (CCK) receptors and their link with nuclear imaging. Imaging methods based on specific metabolic properties include meta-iodo-benzylguanide (MIBG) and dimercapto-sulphuric acid (DMSA-V) scintigraphy as well as more modern positron emission tomography (PET)-based methods using radio-labeled analogues of amino acids, glucose, dihydroxyphenylalanine (DOPA), dopamine and tryptophan. Diagnostic sensitivities are presented for each imaging method and for each neuroendocrine tumor subtype. Finally, a Forest plot analysis of diagnostic performance is presented for each tumor type in order to provide a comprehensive overview for clinical use.
Glais, Laurent; Jacquot, Emmanuel
2015-01-01
Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.
Asero, Riccardo
2005-09-01
Molecular biology techniques have led to the identification of a number of allergens in vegetable foods, but due to the lack of purified food proteins for routine diagnostic use, the detection of sensitizing allergens remains a nearly impossible task in most clinical settings. The allergen-resolved diagnosis of food allergy is essential because each plant-derived food may contain a number of different allergens showing different physical/chemical characteristics that strongly influence the clinical expression of allergy; moreover, many allergens may cross-react with homologue proteins present in botanically unrelated vegetable foods. Through a review of the available literature, this study aimed to detect "markers" of sensitization to specific plant food allergens that are easily accessible in the clinical practice. There are several "markers" of sensitization to different allergenic proteins in vegetable foods that can be helpful in the clinical practice. Specific algorithms for patients allergic to Rosaceae and to tree nuts were built. Clinical allergologists lacking the assistance of an advanced molecular biology lab may take advantage of some specific clinical data as well as of some "markers" in the difficult task of correctly diagnosing patients with plant food allergy and to provide them the best preventive advice. Copyright (c) 2005 S. Karger AG, Basel.
[Differentiation of species within the Mycobacterium tuberculosis complex by molecular techniques].
Herrera-León, Laura; Pozuelo-Díaz, Rodolfo; Molina Moreno, Tamara; Valverde Cobacho, Azucena; Saiz Vega, Pilar; Jiménez Pajares, María Soledad
2009-11-01
The Mycobacterium tuberculosis complex includes the following species: Mycobacterium tuberculosis, Mycobacterium africanum, Mycobacterium bovis, Mycobacterium bovis-BCG, Mycobacterium microti, Mycobacterium caprae, Mycobacterium pinnipedii, and Mycobacterium canettii. These species cause tuberculosis in humans and animals. Identification of mycobacterial strains has classically been performed by phenotype study. Over the last years, laboratories have developed several molecular techniques to differentiate between these species. The aim of this study is to evaluate these methods and develop a simple, fast, identification scheme. We analyzed 251 strains randomly obtained from the strains studied in 2004, and 797 strains received by the Reference Laboratory between 2005 and 2007. Phenotype characterization of 4183 strains isolated during that period was done by studying the colony morphology, characteristics in culture, nitrate reduction, niacin accumulation, and growth in the presence of thiophen-2-carboxylic acid hydrazide 10 microg/mL and pyrazinamide 50 microg/mL. The molecular identification scheme designed was as follows: 1) gyrB PCR-RFLP with RsaI, TaqI or SacII and hsp65 RFLP/PCR with HhaI., and 2) multiplex-PCR to determine the presence/absence of the RD9 and RD1 regions. The results showed 100% agreement between phenotype study and the molecular scheme. This molecular identification scheme is a simple and fast method, with 100% sensitivity and specificity, that can be implemented in most clinical laboratories at a low cost.
236U measurement with accelerator mass spectrometry at CIAE
NASA Astrophysics Data System (ADS)
Wang, Xianggao; Jiang, Shan; He, Ming; Dong, Kejun; Wang, Wei; Li, Chaoli; He, Guozhu; Li, Shizhuo; Gong, Jie; Lu, Liyuan; Wu, Shaoyong
2010-07-01
236U is a long-lived radioactive isotope which is produced principally by thermal neutron capture on 235U. 236U may be potentially applied in geological research and nuclear safeguards. Accelerator mass spectrometry is presently the most sensitive technique for the measurement of 236U and a measurement method for long-lived heavy ion 236U has been developed. The set-up uses a dedicated injector and the newly proposed 208Pb 16O2- molecular ions for the simulation of 236U ion transport. A sensitivity of lower than 10 -10 has been achieved for the isotopic ratio 236U/ 238U in present work.
Vidal-Melgosa, Silvia; Pedersen, Henriette L; Schückel, Julia; Arnal, Grégory; Dumon, Claire; Amby, Daniel B; Monrad, Rune Nygaard; Westereng, Bjørge; Willats, William G T
2015-04-03
Carbohydrate-active enzymes have multiple biological roles and industrial applications. Advances in genome and transcriptome sequencing together with associated bioinformatics tools have identified vast numbers of putative carbohydrate-degrading and -modifying enzymes including glycoside hydrolases and lytic polysaccharide monooxygenases. However, there is a paucity of methods for rapidly screening the activities of these enzymes. By combining the multiplexing capacity of carbohydrate microarrays with the specificity of molecular probes, we have developed a sensitive, high throughput, and versatile semiquantitative enzyme screening technique that requires low amounts of enzyme and substrate. The method can be used to assess the activities of single enzymes, enzyme mixtures, and crude culture broths against single substrates, substrate mixtures, and biomass samples. Moreover, we show that the technique can be used to analyze both endo-acting and exo-acting glycoside hydrolases, polysaccharide lyases, carbohydrate esterases, and lytic polysaccharide monooxygenases. We demonstrate the potential of the technique by identifying the substrate specificities of purified uncharacterized enzymes and by screening enzyme activities from fungal culture broths. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Czaplicki, Lauren M.; Gunsch, Claudia K.
2017-01-01
Bioremediation is generally viewed as a cost effective and sustainable technology because it relies on microbes to transform pollutants into benign compounds. Advances in molecular biological analyses allow unprecedented microbial detection and are increasingly incorporated into bioremediation. Throughout history, state-of-the-art techniques have informed bioremediation strategies. However, the insights those techniques provided were not as in depth as those provided by recently developed omics tools. Advances in next generation sequencing (NGS) have now placed metagenomics and metatranscriptomics within reach of environmental engineers. As NGS costs decrease, metagenomics and metatranscriptomics have become increasingly feasible options to rapidly scan sites for specific degradative functions and identify microorganisms important in pollutant degradation. These omic techniques are capable of revolutionizing biological treatment in environmental engineering by allowing highly sensitive characterization of previously uncultured microorganisms. Omics enables the discovery of novel microorganisms for use in bioaugmentation and supports systematic optimization of biostimulation strategies. This review describes the omics journey from roots in biology and medicine to its current status in environmental engineering including potential future directions in commercial application. PMID:28348455
Moreno, Elizabeth Castro; Gonçalves, Andréa Vieira; Chaves, Anderson Vieira; Melo, Maria Norma; Lambertucci, José Roberto; Andrade, Antero Silva Ribeiro; Negrão-Corrêa, Deborah; Antunes, Carlos Mauricio de Figueiredo; Carneiro, Mariângela
2009-01-01
Background One of the most important drawbacks in visceral leishmaniasis (VL) population studies is the difficulty of diagnosing asymptomatic carriers. The aim of this study, conducted in an urban area in the Southeast of Brazil, was to evaluate the performance of serology to identify asymptomatic VL infection in participants selected from a cohort with a two-year follow-up period. Methodology Blood samples were collected in 2001 from 136 cohort participants (97 positive and 39 negatives, PCR/hybridization carried out in 1999). They were clinically evaluated and none had progressed to disease from their asymptomatic state. As controls, blood samples from 22 control individuals and 8 patients with kala-azar were collected. Two molecular biology techniques (reference tests) were performed: PCR with Leishmania-generic primer followed by hybridization using L. infantum probe, and PCR with specific primer to L. donovani complex. Plasma samples were tested by ELISA using three different antigens: L. infantum and L. amazonensis crude antigens, and rK39 recombinant protein. Accuracy of the serological tests was evaluated using sensitivity, specificity, likelihood ratio and ROC curve. Findings The presence of Leishmania was confirmed, by molecular techniques, in all kala-azar patients and in 117 (86%) of the 136 cohort participants. Kala-azar patients showed high reactivity in ELISAs, whereas asymptomatic individuals presented low reactivity against the antigens tested. When compared to molecular techniques, the L. amazonensis and L. infantum antigens showed higher sensitivity (49.6% and 41.0%, respectively) than rK39 (26.5%); however, the specificity of rK39 was higher (73.7%) than L. amazonensis (52.6%) and L. infantum antigens (36.8%). Moreover, there was low agreement among the different antigens used (kappa<0.10). Conclusions Serological tests were inaccurate for diagnosing asymptomatic infections compared to molecular methods; this could lead to misclassification bias in population studies. Therefore, studies which have used serological assays to estimate prevalence, to evaluate intervention programs or to identify risk factors for Leishmania infection, may have had their results compromised. PMID:19841736
Nanotechnology: a promising method for oral cancer detection and diagnosis.
Chen, Xiao-Jie; Zhang, Xue-Qiong; Liu, Qi; Zhang, Jing; Zhou, Gang
2018-06-11
Oral cancer is a common and aggressive cancer with high morbidity, mortality, and recurrence rate globally. Early detection is of utmost importance for cancer prevention and disease management. Currently, tissue biopsy remains the gold standard for oral cancer diagnosis, but it is invasive, which may cause patient discomfort. The application of traditional noninvasive methods-such as vital staining, exfoliative cytology, and molecular imaging-is limited by insufficient sensitivity and specificity. Thus, there is an urgent need for exploring noninvasive, highly sensitive, and specific diagnostic techniques. Nano detection systems are known as new emerging noninvasive strategies that bring the detection sensitivity of biomarkers to nano-scale. Moreover, compared to current imaging contrast agents, nanoparticles are more biocompatible, easier to synthesize, and able to target specific surface molecules. Nanoparticles generate localized surface plasmon resonances at near-infrared wavelengths, providing higher image contrast and resolution. Therefore, using nano-based techniques can help clinicians to detect and better monitor diseases during different phases of oral malignancy. Here, we review the progress of nanotechnology-based methods in oral cancer detection and diagnosis.
Giardiasis: an update review on sensitivity and specificity of methods for laboratorial diagnosis.
Soares, Renata; Tasca, Tiana
2016-10-01
Giardiasis is a major cause of diarrhoea transmitted by ingestion of contaminated water and food with cysts, and it has been spread among people with poor oral hygiene. The traditional diagnosis is performed by identifying trophozoites and cysts of Giardia duodenalis through microscopy of faecal samples. In addition to microscopy, different methods have been validated for giardiasis diagnosis which are based on immunologic and molecular analyses. The aim of this study was to conduct a review of the main methods applied in clinical laboratory for diagnosis of giardiasis, in the last 10years, regarding the specificity and sensitivity criteria. It was observed high variability in the performance of the same methodology across studies; however, several techniques have been considered better than microscopy. The later, although gold standard, presents low sensitivity in cases of low number of cysts in the sample, and the experience of the microscopist must also be considered. We conclude that microscopy should still be held and complementary technique is recommended, in order to provide a reliable diagnosis and a proper treatment of the patient. Copyright © 2016 Elsevier B.V. All rights reserved.
Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy
NASA Technical Reports Server (NTRS)
Cooper, David E.
1986-01-01
Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.
NASA Astrophysics Data System (ADS)
Mumm, H. P.; Huber, M.; Bauder, W.; Abrams, N.; Deibel, C.; Huffer, C.; Huffman, P.; Schelhammer, K.; Janssens, R.; Jiang, C.; Scott, R.; Pardo, R.; Rehm, K.; Vondrasek, R.; Swank, C.; O'Shaughnessy, C.; Paul, M.; Yang, L.
2017-01-01
We report the development of an Accelerator Mass Spectrometry technique to measure the 3He/4He isotopic ratio using a radio frequency (RF) discharge source and the ATLAS facility at Argonne National Laboratory. Control over 3He/4He ratio in helium several orders of magnitude lower than natural abundance is critical for neutron lifetime and source experiments using liquid helium. Due to low ultimate beam currents, the ATLAS accelerator and beam line were tuned using a succession of species of the same M/q. A unique RF source was developed for the experiment due to large natural 3He backgrounds. Analog H_3 + and DH + molecular ions are eliminated by dissociation via a gold stripper foil near the detector. The stripped ions were dispersed in a magnetic spectrograph and 3He2 + ions counted in the focal plane detector. This technique is sensitive to 3 He /4 He ratios in the regime of 10-12 with backgrounds that appear to be below 10-14. The techniques used to reduce the backgrounds and remaining outstanding problems will be presented along with results from measurements on high purity 4He samples.
Monteiro, Liziane O F; Malachias, Ângelo; Pound-Lana, Gwenaelle; Magalhães-Paniago, Rogério; Mosqueira, Vanessa C F; Oliveira, Mônica C; de Barros, André Luís B; Leite, Elaine A
2018-05-22
A long-circulating and pH-sensitive liposome containing paclitaxel (SpHL-PTX) was recently developed by our group. Once in an acidic environment, for example, tumors, these liposomes undergo destabilization, releasing the encapsulated drug. In this way, the aim of this study was to evaluate the molecular and supramolecular interactions between the lipid bilayer and PTX in similar biological environment conditions. High-sensitivity analyses of SpHL-PTX structures were obtained by the small-angle X-ray scattering technique combined with other techniques such as dynamic light scattering, asymmetric flow field-flow fractionation, transmission electron microscopy, and high-performance liquid chromatography. The results showed that PTX incorporation in the liposomal bilayer clearly leads to changes in supramolecular organization of dioleoylphosphatidylethanolamine (DOPE) molecules, inducing the formation of more ordered structures. Changes in supramolecular organization were observed at lower pH, indicating that pH sensitivity was preserved even in the presence of fetal bovine serum proteins. Furthermore, morphological and physicochemical characterization of SpHL-PTX evidenced the formation of nanosized dispersion suitable for intravenous administration. In conclusion, a stable nanosized dispersion of PTX was obtained at pH 7.4 with suitable parameters for intravenous administration. At lower pH conditions, the pH sensitivity of the system was clearly evidenced by changes in the supramolecular organization of DOPE molecules, which is crucial for the delivery of PTX into the cytoplasm of the targeted cells. In this way, the results obtained by different techniques confirm the feasibility of SpHL as a promising tool to PTX delivery in acidic environments, such as tumors.
Laser-induced contamination control for high-power lasers in space-based LIDAR missions
NASA Astrophysics Data System (ADS)
Alves, Jorge; Pettazzi, Federico; Tighe, Adrian; Wernham, Denny
2017-11-01
In the framework of the ADM-Aeolus satellite mission, successful test campaigns have been performed in ESTEC's laser laboratory, and the efficiency of several mitigation techniques against Laser-Induced Contamination (LIC) have been demonstrated for the ALADIN laser. These techniques include the standard contamination control methods of materials identification with particular tendency to cause LIC, reduction of the outgassing of organic materials by vacuum bake-out and shielding of optical surfaces from the contamination sources. Also novel mitigation methods such as in-situ cleaning via partial pressures, or the usage of molecular absorbers were demonstrated. In this context, a number of highly sensitive optical measurement techniques have been developed and tested to detect and monitor LIC deposits at nanometre level.
NASA Astrophysics Data System (ADS)
Saha, Subhrakanti; Chen, Lee Chuin; Mandal, Mridul Kanti; Hiraoka, Kenzo
2013-03-01
This work describes the development and application of a new thermal desorption technique that makes use of the Leidenfrost phenomenon in open ion sources at atmospheric pressure for direct mass spectrometric detection of ultratrace levels of illicit, therapeutic, and stimulant drugs, toxicants, and peptides (molecular weight above 1 kDa) in their unaltered state from complex real world samples without or with minor sample pretreatment. A low temperature dielectric barrier discharge ion source was used throughout the experiments and the analytical figures of merit of this technique were investigated. Further, this desorption technique coupled with other ionization sources such as electrospray ionization (ESI) and dc corona discharge atmospheric pressure chemical ionization (APCI) in open atmosphere was also investigated. The use of the high-resolution `Exactive Orbitrap' mass spectrometer provided unambiguous identification of trace levels of the targeted compounds from complex mixtures and background noise; the limits of detection for various small organic molecules and peptides treated with this technique were at the level of parts per trillion and 10-9 M, respectively. The high sensitivity of the present technique is attributed to the spontaneous enrichment of analyte molecules during the slow evaporation of the solvent, as well as to the sequential desorption of molecules from complex mixtures based on their volatilities. This newly developed desorption technique is simple and fast, while molecular ions are observed as the major ions.
Non destructive examination of interface of molecular assembly
NASA Astrophysics Data System (ADS)
Perez, Guy; Richard, Isaline; Lecomte, Jean-Claude
2017-11-01
Molecular assembly interfaces can be characterised by mechanical testing and/or the interaction between waves and the interface. The disadvantage of the mechanical approach is that new defects may be produced at the interface, or existing defects may be destroyed. Using the interaction between waves and the interface is a non-destructive approach. But what kind of waves should be used? Electromagnetic waves in the visible range depend on wave attenuation in the material, infrared waves also depend on the thickness and X-ray waves have a too short a wave length to detect interface defects. In this article, the use of acoustic waves is proposed for non-destructive examination of molecular assembly interfaces. Acoustic wave propagation is very sensitive to variations in interface characteristics depending on whether the waves are reflected or transmitted. To improve the sensitivity and resolution of this technique, small wave lengths have been used with a scanning acoustic microscope (S.A.M.) with a band width from 1MHz to 400 MHz. After a short description of the principle of the method, results are given for different types of components. Different applications of acoustic microscopy are proposed for non-destructive examination of interfaces and defect detection in materials.
Giustacchini, Alice; Thongjuea, Supat; Barkas, Nikolaos; Woll, Petter S; Povinelli, Benjamin J; Booth, Christopher A G; Sopp, Paul; Norfo, Ruggiero; Rodriguez-Meira, Alba; Ashley, Neil; Jamieson, Lauren; Vyas, Paresh; Anderson, Kristina; Segerstolpe, Åsa; Qian, Hong; Olsson-Strömberg, Ulla; Mustjoki, Satu; Sandberg, Rickard; Jacobsen, Sten Eirik W; Mead, Adam J
2017-06-01
Recent advances in single-cell transcriptomics are ideally placed to unravel intratumoral heterogeneity and selective resistance of cancer stem cell (SC) subpopulations to molecularly targeted cancer therapies. However, current single-cell RNA-sequencing approaches lack the sensitivity required to reliably detect somatic mutations. We developed a method that combines high-sensitivity mutation detection with whole-transcriptome analysis of the same single cell. We applied this technique to analyze more than 2,000 SCs from patients with chronic myeloid leukemia (CML) throughout the disease course, revealing heterogeneity of CML-SCs, including the identification of a subgroup of CML-SCs with a distinct molecular signature that selectively persisted during prolonged therapy. Analysis of nonleukemic SCs from patients with CML also provided new insights into cell-extrinsic disruption of hematopoiesis in CML associated with clinical outcome. Furthermore, we used this single-cell approach to identify a blast-crisis-specific SC population, which was also present in a subclone of CML-SCs during the chronic phase in a patient who subsequently developed blast crisis. This approach, which might be broadly applied to any malignancy, illustrates how single-cell analysis can identify subpopulations of therapy-resistant SCs that are not apparent through cell-population analysis.
Bioimaging of cells and tissues using accelerator-based sources.
Petibois, Cyril; Cestelli Guidi, Mariangela
2008-07-01
A variety of techniques exist that provide chemical information in the form of a spatially resolved image: electron microprobe analysis, nuclear microprobe analysis, synchrotron radiation microprobe analysis, secondary ion mass spectrometry, and confocal fluorescence microscopy. Linear (LINAC) and circular (synchrotrons) particle accelerators have been constructed worldwide to provide to the scientific community unprecedented analytical performances. Now, these facilities match at least one of the three analytical features required for the biological field: (1) a sufficient spatial resolution for single cell (< 1 mum) or tissue (<1 mm) analyses, (2) a temporal resolution to follow molecular dynamics, and (3) a sensitivity in the micromolar to nanomolar range, thus allowing true investigations on biological dynamics. Third-generation synchrotrons now offer the opportunity of bioanalytical measurements at nanometer resolutions with incredible sensitivity. Linear accelerators are more specialized in their physical features but may exceed synchrotron performances. All these techniques have become irreplaceable tools for developing knowledge in biology. This review highlights the pros and cons of the most popular techniques that have been implemented on accelerator-based sources to address analytical issues on biological specimens.
Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai
2014-04-01
Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.
Investigating the Endobacteria Which Thrive in Arbuscular Mycorrhizal Fungi.
Desirò, Alessandro; Salvioli, Alessandra; Bonfante, Paola
2016-01-01
The study of the so-called unculturable bacteria is still considered a challenging task. However, given recent improvements in the sensitivity of culture-free approaches, the identification and characterization of such microbes in complex biological samples is now possible. In this chapter we report how endobacteria thriving inside arbuscular mycorrhizal fungi (AMF), which are themselves obligate biotrophs of plants, can be studied using a combination of in vitro culture, molecular biology, and microscopy techniques.
NASA Astrophysics Data System (ADS)
Palomaki, Peter Karl Bunk
Solar energy may be the only renewable source of energy available to the human race that could provide the energy we require while at the same time minimizing negative impacts on the planet and population. These characteristics may be instrumental in diminishing the potential for societal conflict. In order for photovoltaic devices to succeed on a global scale, research and development must lead to reduced costs and/or increased efficiency. Dye-Sensitized Solar Cells (DSSCs) are one class of nextgeneration photovoltaic technologies with the potential to realize these goals. Herein, I describe efforts towards developing a new light harvesting array of chromophores assembled on oxide substrates using copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC or ‘click’ chemistry) that could prove useful in improving DSCC performance while maintaining low cost and simple fabrication. Specifically, molecular multilayers of porphyrin-based chromophores have been fabricated via sequential selflimiting CuAAC reactions to generate multilayered light harvesting films. Films of synthetic porphyrins, perylenes, and mixtures of the two are constructed in order to highlight the versatility of this molecular layer-by-layer (LbL) technique. Characterization in the form of electrochemical techniques, UV-Visible spectroscopy, infrared spectroscopy (IR), and water contact angle all indicate that the films are reacting as expected. Film thickness and morphology are investigated using X-ray reflectivity showing that film growth displays a high degree of linearity, while the roughness increases with thickness. Growth angles based on the porphyrin plane are estimated via a comparison of molecular models and experimentally determined thickness measurements. A more finite measurement of growth angle (and as a result the primary bonding mode) is determined by grazing angle IR spectroscopy. Blocking layer studies suggest that the films could be useful as a self-passivating layer in DSSCs to reduce recombination effects and improve DSSC device efficiency. Porphyrin light harvesting films assembled on ITO show a cathodic photocurrent when assembled in a DSSC device. Cobalt2+/3+ and I- /I3- redox mediators are commonly used in DSSCs as an electron shuttle. Experiments with cobalt2+/3+ redox mediators as well as I-/I3- provide an initial benchmark for the performance of unoptimized solar cells with multilayered porphyrin sensitizer films. Devices operating with I -/I3- show the largest photocurrents, but low open circuit potentials. Devices using cobalt2+/3+ result in lower photocurrents but greater operating potentials than I-/I 3-. For all redox mediators tested, photocurrent increases with the addition of porphyrin layers beyond a monolayer. However, photocurrent reaches a maximum value at a point greater than one layer, after which it decreases. This demonstrates that multilayered porphyrin light harvesting films can be beneficial to improving DSSC performance but optimal film thickness (number of layers) is dependent on the redox mediator. This facile and versatile technique for creating molecular multilayer films may have implications in light harvesting materials, sensors, and molecular electronics. It could be amenable to large scale roll-to-roll processing which would be advantageous for applications requiring large surface area depositions. In summary, these techniques allow for simple and rapid evaluation of numerous molecular components in light harvesting arrays that could lead to much needed breakthroughs in solar applications.
Extreme sensitivity biosensing platform based on hyperbolic metamaterials
NASA Astrophysics Data System (ADS)
Sreekanth, Kandammathe Valiyaveedu; Alapan, Yunus; Elkabbash, Mohamed; Ilker, Efe; Hinczewski, Michael; Gurkan, Umut A.; de Luca, Antonio; Strangi, Giuseppe
2016-06-01
Optical sensor technology offers significant opportunities in the field of medical research and clinical diagnostics, particularly for the detection of small numbers of molecules in highly diluted solutions. Several methods have been developed for this purpose, including label-free plasmonic biosensors based on metamaterials. However, the detection of lower-molecular-weight (<500 Da) biomolecules in highly diluted solutions is still a challenging issue owing to their lower polarizability. In this context, we have developed a miniaturized plasmonic biosensor platform based on a hyperbolic metamaterial that can support highly confined bulk plasmon guided modes over a broad wavelength range from visible to near infrared. By exciting these modes using a grating-coupling technique, we achieved different extreme sensitivity modes with a maximum of 30,000 nm per refractive index unit (RIU) and a record figure of merit (FOM) of 590. We report the ability of the metamaterial platform to detect ultralow-molecular-weight (244 Da) biomolecules at picomolar concentrations using a standard affinity model streptavidin-biotin.
Byron, Meg; Hall, Lisa L; Lawrence, Jeanne B
2013-01-01
Fluorescence in situ hybridization (FISH) is not a singular technique, but a battery of powerful and versatile tools for examining the distribution of endogenous genes and RNAs in precise context with each other and in relation to specific proteins or cell structures. This unit offers the details of highly sensitive and successful protocols that were initially developed largely in our lab and honed over a number of years. Our emphasis is on analysis of nuclear RNAs and DNA to address specific biological questions about nuclear structure, pre-mRNA metabolism, or the role of noncoding RNAs; however, cytoplasmic RNA detection is also discussed. Multifaceted molecular cytological approaches bring precise resolution and sensitive multicolor detection to illuminate the organization and functional roles of endogenous genes and their RNAs within the native structure of fixed cells. Solutions to several common technical pitfalls are discussed, as are cautions regarding the judicious use of digital imaging and the rigors of analyzing and interpreting complex molecular cytological results.
Park, Joong-Ki; Rho, Hyun Soo; Kristensen, Reinhardt Møbjerg; Kim, Won; Giribet, Gonzalo
2006-11-01
Recent progress in molecular techniques has generated a wealth of information for phylogenetic analysis. Among metazoans all but a single phylum have been incorporated into some sort of molecular analysis. However, the minute and rare species of the phylum Loricifera have remained elusive to molecular systematists. Here we report the first molecular sequence data (nearly complete 18S rRNA) for a member of the phylum Loricifera, Pliciloricus sp. from Korea. The new sequence data were analyzed together with 52 other ecdysozoan sequences, with all other phyla represented by three or more sequences. The data set was analyzed using parsimony as an optimality criterion under direct optimization as well as using a Bayesian approach. The parsimony analysis was also accompanied by a sensitivity analysis. The results of both analyses are largely congruent, finding monophyly of each ecdysozoan phylum, except for Priapulida, in which the coelomate Meiopriapulus is separate from a clade of pseudocoelomate priapulids. The data also suggest a relationship of the pseudocoelomate priapulids to kinorhynchs, and a relationship of nematodes to tardigrades. The Bayesian analysis placed the arthropods as the sister group to a clade that includes tardigrades and nematodes. However, these results were shown to be parameter dependent in the sensitivity analysis. The position of Loricifera was extremely unstable to parameter variation, and support for a relationship of loriciferans to any particular ecdysozoan phylum was not found in the data.
El-Naby, Eman H; Kamel, Ayman H
2015-09-01
A biomimetic potentiometric sensor for specific recognition of dextromethorphan (DXM), a drug classified according to the Drug Enforcement Administration (DEA) as a "drug of concern", is designed and characterized. A molecularly imprinted polymer (MIP), with special molecular recognition properties of DXM, was prepared by thermal polymerization in which DXM acted as template molecule, methacrylic acid (MAA) and acrylonitrile (AN) acted as functional monomers in the presence of ethylene glycol dimethacrylate (EGDMA) as crosslinker. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors revealed near-Nernstian response with slopes of 49.6±0.5 and 53.4±0.5 mV decade(-1) with a detection limit of 1.9×10(-6), and 1.0×10(-6) mol L(-1) DXM with MIP/MAA and MIP/AN membrane based sensors, respectively. Significantly improved accuracy, precision, response time, stability, selectivity and sensitivity were offered by these simple and cost-effective potentiometric sensors compared with other standard techniques. The method has the requisite accuracy, sensitivity and precision to assay DXM in pharmaceutical products. Copyright © 2015 Elsevier B.V. All rights reserved.
Highly sensitive detection of molecular interactions with plasmonic optical fiber grating sensors.
Voisin, Valérie; Pilate, Julie; Damman, Pascal; Mégret, Patrice; Caucheteur, Christophe
2014-01-15
Surface Plasmon resonance (SPR) optical fiber biosensors constitute a miniaturized counterpart to the bulky prism configuration and offer remote operation in very small volumes of analyte. They are a cost-effective and relatively straightforward technique to yield in situ (or even possibly in vivo) molecular detection. The biosensor configuration reported in this work uses nanometric-scale gold-coated tilted fiber Bragg gratings (TFBGs) interrogated by light polarized radially to the optical fiber outer surface, so as to maximize the optical coupling with the SPR. These gratings were recently associated to aptamers to assess their label-free biorecognition capability in buffer and serum solutions. In this work, using the well-acknowledged biotin-streptavidin pair as a benchmark, we go forward in the demonstration of their unique sensitivity. In addition to the monitoring of the self-assembled monolayer (SAM) in real time, we report an unprecedented limit of detection (LOD) as low as 2 pM. Finally, an immunosensing experiment is realized with human transferrin (dissociation constant Kd~10(-8) M(-1)). It allows to assess both the reversibility and the robustness of the SPR-TFBG biosensors and to confirm their high sensitivity. © 2013 Published by Elsevier B.V.
Hane, Francis T.; Li, Tao; Smylie, Peter; Pellizzari, Raiili M.; Plata, Jennifer A.; DeBoef, Brenton; Albert, Mitchell S.
2017-01-01
The Hyperpolarized gas Chemical Exchange Saturation Transfer (HyperCEST) Magnetic Resonance (MR) technique has the potential to increase the sensitivity of a hyperpolarized xenon-129 MRI contrast agent. Signal enhancement is accomplished by selectively depolarizing the xenon within a cage molecule which, upon exchange, reduces the signal in the dissolved phase pool. Herein we demonstrate the in vivo detection of the cucurbit[6]uril (CB6) contrast agent within the vasculature of a living rat. Our work may be used as a stepping stone towards using the HyperCEST technique as a molecular imaging modality. PMID:28106110
Mm-Wave Spectroscopic Sensors, Catalogs, and Uncatalogued Lines
NASA Astrophysics Data System (ADS)
Medvedev, Ivan; Neese, Christopher F.; De Lucia, Frank C.
2014-06-01
Analytical chemical sensing based on high resolution rotational molecular spectra has been recognized as a viable technique for decades. We recently demonstrated a compact implementation of such a sensor. Future generations of these sensors will rely on automated algorithms for quantification of chemical dilutions based on their spectral libraries, as well as identification of spectral features not present in spectral catalogs. Here we present an algorithm aimed at detection of unidentified lines in complex molecular species based on spectroscopic libraries developed in our previous projects. We will discuss the approaches suitable for data mining in feature-rich rotational molecular spectra. Neese, C.F., I.R. Medvedev, G.M. Plummer, A.J. Frank, C.D. Ball, and F.C. De Lucia, "A Compact Submillimeter/Terahertz Gas Sensor with Efficient Gas Collection, Preconcentration, and ppt Sensitivity." Sensors Journal, IEEE, 2012. 12(8): p. 2565-2574
Temporal mapping of photochemical reactions and molecular excited states with carbon specificity
NASA Astrophysics Data System (ADS)
Wang, K.; Murahari, P.; Yokoyama, K.; Lord, J. S.; Pratt, F. L.; He, J.; Schulz, L.; Willis, M.; Anthony, J. E.; Morley, N. A.; Nuccio, L.; Misquitta, A.; Dunstan, D. J.; Shimomura, K.; Watanabe, I.; Zhang, S.; Heathcote, P.; Drew, A. J.
2017-04-01
Photochemical reactions are essential to a large number of important industrial and biological processes. A method for monitoring photochemical reaction kinetics and the dynamics of molecular excitations with spatial resolution within the active molecule would allow a rigorous exploration of the pathway and mechanism of photophysical and photochemical processes. Here we demonstrate that laser-excited muon pump-probe spin spectroscopy (photo-μSR) can temporally and spatially map these processes with a spatial resolution at the single-carbon level in a molecule with a pentacene backbone. The observed time-dependent light-induced changes of an avoided level crossing resonance demonstrate that the photochemical reactivity of a specific carbon atom is modified as a result of the presence of the excited state wavefunction. This demonstrates the sensitivity and potential of this technique in probing molecular excitations and photochemistry.
Molecular fluorescence as a monitor of minor stratospheric constituents
NASA Technical Reports Server (NTRS)
Schofield, K.
1975-01-01
The potential of molecular fluorescence was assessed as a stratospheric monitor of the concentrations of various minor species. Seventeen molecules were considered and all spectral regions from the vacuum ultraviolet through to the infrared are included. The exercise has produced few surprises; however, further confirmation has emerged as to the feasibility of this sensitive technique for monitoring stratospheric OH, NO2, and SO2, sufficient to warrant its development as analytical flight hardware for these species. All the other molecules have been eliminated with the exception of C10 which appears to have promise but requires additional information before its detection limit can be calculated; its fluorescence spectrum is as yet uninvestigated. A handbook for molecular fluorescence is presented, and a compilation of all reported studies for simple molecules using line source excitation is included.
Diagnostic procedures in tularaemia with special focus on molecular and immunological techniques.
Splettstoesser, W D; Tomaso, H; Al Dahouk, S; Neubauer, H; Schuff-Werner, P
2005-08-01
Tularaemia is a severe bacterial zoonosis caused by the highly infectious agent Francisella tularensis. It is endemic in countries of the northern hemisphere ranging from North America to Europe, Asia and Japan. Very recently, Francisella-like strains causing disease in humans were described from tropical northern Australia. In the last decade, efforts have been made to develop sensitive and specific immunological and molecular techniques for the laboratory diagnosis of tularaemia and also for the definite identification of members of the species F. tularensis and its four subspecies. Screening for the keyword 'Francisella' a Medline search over the last decade was performed and articles describing diagnostic methods for tularaemia and its causative agent were selected. Besides classical microbiological techniques (cultivation, biochemical profiling, susceptibility testing) several new immunological and molecular approaches to identify F. tularensis have been introduced employing highly specific antibodies and various polymerase chain reaction (PCR)-based methods. Whereas direct antigen detection by enzyme-linked immunosorbent assay (ELISA) or immunofluorescence might allow early presumptive diagnosis of tularaemia, these methods--like all PCR techniques--still await further evaluation. Therefore, diagnosis of tularaemia still relies mainly on the demonstration of specific antibodies in the host. ELISA and immunoblot methods started to replace the standard tube or micro-agglutination assays. However, the diagnostic value of antibody detection in the very early clinical phase of tularaemia is limited. Francisella tularensis is regarded as a 'highest priority' biological agent (category 'A' according to the CDC, Atlanta, GA, USA), thus rapid and reliable diagnosis of tularaemia is required not only for a timely onset of therapy, the handling of outbreak investigations but also for the surveillance of endemic foci. Only very recently, evaluated test kits for serological diagnosis of human tularaemia became available, while the introduction of standardized molecular techniques for detection and typing is still missing.
The dawn of the liquid biopsy in the fight against cancer
Domínguez-Vigil, Irma G.; Moreno-Martínez, Ana K.; Wang, Julia Y.; Roehrl, Michael H.A.; Barrera-Saldaña, Hugo A.
2018-01-01
Cancer is a molecular disease associated with alterations in the genome, which, thanks to the highly improved sensitivity of mutation detection techniques, can be identified in cell-free DNA (cfDNA) circulating in blood, a method also called liquid biopsy. This is a non-invasive alternative to surgical biopsy and has the potential of revealing the molecular signature of tumors to aid in the individualization of treatments. In this review, we focus on cfDNA analysis, its advantages, and clinical applications employing genomic tools (NGS and dPCR) particularly in the field of oncology, and highlight its valuable contributions to early detection, prognosis, and prediction of treatment response. PMID:29416824
Chirped Laser Dispersion Spectroscopy for Remote Open-Path Trace-Gas Sensing
Nikodem, Michal; Wysocki, Gerard
2012-01-01
In this paper we present a prototype instrument for remote open-path detection of nitrous oxide. The sensor is based on a 4.53 μm quantum cascade laser and uses the chirped laser dispersion spectroscopy (CLaDS) technique for molecular concentration measurements. To the best of our knowledge this is the first demonstration of open-path laser-based trace-gas detection using a molecular dispersion measurement. The prototype sensor achieves a detection limit down to the single-ppbv level and exhibits excellent stability and robustness. The instrument characterization, field deployment performance, and the advantages of applying dispersion sensing to sensitive trace-gas detection in a remote open-path configuration are presented. PMID:23443389
Chirped laser dispersion spectroscopy for remote open-path trace-gas sensing.
Nikodem, Michal; Wysocki, Gerard
2012-11-28
In this paper we present a prototype instrument for remote open-path detection of nitrous oxide. The sensor is based on a 4.53 μm quantum cascade laser and uses the chirped laser dispersion spectroscopy (CLaDS) technique for molecular concentration measurements. To the best of our knowledge this is the first demonstration of open-path laser-based trace-gas detection using a molecular dispersion measurement. The prototype sensor achieves a detection limit down to the single-ppbv level and exhibits excellent stability and robustness. The instrument characterization, field deployment performance, and the advantages of applying dispersion sensing to sensitive trace-gas detection in a remote open-path configuration are presented.
Detection of early primary colorectal cancer with upconversion luminescent NP-based molecular probes
NASA Astrophysics Data System (ADS)
Liu, Chunyan; Qi, Yifei; Qiao, Ruirui; Hou, Yi; Chan, Kaying; Li, Ziqian; Huang, Jiayi; Jing, Lihong; Du, Jun; Gao, Mingyuan
2016-06-01
Early detection and diagnosis of cancers is extremely beneficial for improving the survival rate of cancer patients and molecular imaging techniques are believed to be relevant for offering clinical solutions. Towards early cancer detection, we developed a primary animal colorectal cancer model and constructed a tumor-specific imaging probe by using biocompatible NaGdF4:Yb,Er@NaGdF4 upconversion luminescent NPs for establishing a sensitive early tumor imaging method. The primary animal tumor model, which can better mimic the human colorectal cancer, was built upon continual administration of 1,2-dimethylhydrazine in Kunming mice and the tumor development was carefully monitored through histopathological and immunohistochemical analyses to reveal the pathophysiological processes and molecular features of the cancer microenvironment. The upconversion imaging probe was constructed through covalent coupling of PEGylated core-shell NPs with folic acid whose receptor is highly expressed in the primary tumors. Upon 980 nm laser excitation, the primary colorectal tumors in the complex abdominal environment were sensitively imaged owing to the ultralow background of the upconversion luminescence and the high tumor-targeting specificity of the nanoprobe. We believe that the current studies provide a highly effective and potential approach for early colorectal cancer diagnosis and tumor surgical navigation.Early detection and diagnosis of cancers is extremely beneficial for improving the survival rate of cancer patients and molecular imaging techniques are believed to be relevant for offering clinical solutions. Towards early cancer detection, we developed a primary animal colorectal cancer model and constructed a tumor-specific imaging probe by using biocompatible NaGdF4:Yb,Er@NaGdF4 upconversion luminescent NPs for establishing a sensitive early tumor imaging method. The primary animal tumor model, which can better mimic the human colorectal cancer, was built upon continual administration of 1,2-dimethylhydrazine in Kunming mice and the tumor development was carefully monitored through histopathological and immunohistochemical analyses to reveal the pathophysiological processes and molecular features of the cancer microenvironment. The upconversion imaging probe was constructed through covalent coupling of PEGylated core-shell NPs with folic acid whose receptor is highly expressed in the primary tumors. Upon 980 nm laser excitation, the primary colorectal tumors in the complex abdominal environment were sensitively imaged owing to the ultralow background of the upconversion luminescence and the high tumor-targeting specificity of the nanoprobe. We believe that the current studies provide a highly effective and potential approach for early colorectal cancer diagnosis and tumor surgical navigation. Electronic supplementary information (ESI) available: (1) Molecular structure of Jeffamine-modified FA; (2) immunohistochemical analysis of FR expression in the colorectal tissue derived from mice treated with NaCl at different weeks; (3) biodistributions of probes of NP-FA and NP-IgG in the main organs of mice. See DOI: 10.1039/c5nr07858j
NASA Astrophysics Data System (ADS)
Martin, Michael C.; Holman, Hoi-Ying N.; Blakely, Eleanor A.; Goth-Goldstein, Regine; McKinney, Wayne R.
2000-03-01
Vibrational spectroscopy, when combined with synchrotron radiation-based (SR) microscopy, is a powerful new analytical tool with high spatial resolution for detecting biochemical changes in individual living cells. In contrast to other microscopy methods that require fixing, drying, staining or labeling, SR FTIR microscopy probes intact living cells providing a composite view of all of the molecular responses and the ability to monitor the responses over time in the same cell. Observed spectral changes include all types of lesions induced in that cell as well as cellular responses to external and internal stresses. These spectral changes combined with other analytical tools may provide a fundamental understanding of the key molecular mechanisms induced in response to stresses created by low-doses of radiation and chemicals. In this study we used high spatial-resolution SR FTIR vibrational spectromicroscopy at ALS Beamline 1.4.3 as a sensitive analytical tool to detect chemical- and radiation-induced changes in individual human cells. Our preliminary spectral measurements indicate that this technique is sensitive enough to detect changes in nucleic acids and proteins of cells treated with environmentally relevant concentrations of oxidative stresses: bleomycin, hydrogen peroxide, and X-rays. We observe spectral changes that are unique to each exogenous stressor. This technique has the potential to distinguish changes from exogenous or endogenous oxidative processes. Future development of this technique will allow rapid monitoring of cellular processes such as drug metabolism, early detection of disease, bio-compatibility of implant materials, cellular repair mechanisms, self assembly of cellular apparatus, cell differentiation and fetal development.
Molecular malaria diagnostics: A systematic review and meta-analysis.
Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F
2016-01-01
Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.
Single-molecule experiments in biological physics: methods and applications.
Ritort, F
2006-08-16
I review single-molecule experiments (SMEs) in biological physics. Recent technological developments have provided the tools to design and build scientific instruments of high enough sensitivity and precision to manipulate and visualize individual molecules and measure microscopic forces. Using SMEs it is possible to manipulate molecules one at a time and measure distributions describing molecular properties, characterize the kinetics of biomolecular reactions and detect molecular intermediates. SMEs provide additional information about thermodynamics and kinetics of biomolecular processes. This complements information obtained in traditional bulk assays. In SMEs it is also possible to measure small energies and detect large Brownian deviations in biomolecular reactions, thereby offering new methods and systems to scrutinize the basic foundations of statistical mechanics. This review is written at a very introductory level, emphasizing the importance of SMEs to scientists interested in knowing the common playground of ideas and the interdisciplinary topics accessible by these techniques. The review discusses SMEs from an experimental perspective, first exposing the most common experimental methodologies and later presenting various molecular systems where such techniques have been applied. I briefly discuss experimental techniques such as atomic-force microscopy (AFM), laser optical tweezers (LOTs), magnetic tweezers (MTs), biomembrane force probes (BFPs) and single-molecule fluorescence (SMF). I then present several applications of SME to the study of nucleic acids (DNA, RNA and DNA condensation) and proteins (protein-protein interactions, protein folding and molecular motors). Finally, I discuss applications of SMEs to the study of the nonequilibrium thermodynamics of small systems and the experimental verification of fluctuation theorems. I conclude with a discussion of open questions and future perspectives.
TOPICAL REVIEW: Single-molecule experiments in biological physics: methods and applications
NASA Astrophysics Data System (ADS)
Ritort, F.
2006-08-01
I review single-molecule experiments (SMEs) in biological physics. Recent technological developments have provided the tools to design and build scientific instruments of high enough sensitivity and precision to manipulate and visualize individual molecules and measure microscopic forces. Using SMEs it is possible to manipulate molecules one at a time and measure distributions describing molecular properties, characterize the kinetics of biomolecular reactions and detect molecular intermediates. SMEs provide additional information about thermodynamics and kinetics of biomolecular processes. This complements information obtained in traditional bulk assays. In SMEs it is also possible to measure small energies and detect large Brownian deviations in biomolecular reactions, thereby offering new methods and systems to scrutinize the basic foundations of statistical mechanics. This review is written at a very introductory level, emphasizing the importance of SMEs to scientists interested in knowing the common playground of ideas and the interdisciplinary topics accessible by these techniques. The review discusses SMEs from an experimental perspective, first exposing the most common experimental methodologies and later presenting various molecular systems where such techniques have been applied. I briefly discuss experimental techniques such as atomic-force microscopy (AFM), laser optical tweezers (LOTs), magnetic tweezers (MTs), biomembrane force probes (BFPs) and single-molecule fluorescence (SMF). I then present several applications of SME to the study of nucleic acids (DNA, RNA and DNA condensation) and proteins (protein-protein interactions, protein folding and molecular motors). Finally, I discuss applications of SMEs to the study of the nonequilibrium thermodynamics of small systems and the experimental verification of fluctuation theorems. I conclude with a discussion of open questions and future perspectives.
Gibbons, Don L.; Pricl, Sabrina; Posocco, Paola; Laurini, Erik; Fermeglia, Maurizio; Sun, Hanshi; Talpaz, Moshe; Donato, Nicholas; Quintás-Cardama, Alfonso
2014-01-01
The acquisition of mutations within the BCR-ABL1 kinase domain is frequently associated with tyrosine kinase inhibitor (TKI) failure in chronic myeloid leukemia. Sensitive sequencing techniques have revealed a high prevalence of compound BCR-ABL1 mutations (polymutants) in patients failing TKI therapy. To investigate the molecular consequences of such complex mutant proteins with regards to TKI resistance, we determined by cloning techniques the presence of polymutants in a cohort of chronic-phase patients receiving imatinib followed by dasatinib therapy. The analysis revealed a high frequency of polymutant BCR-ABL1 alleles even after failure of frontline imatinib, and also the progressive exhaustion of the pool of unmutated BCR-ABL1 alleles over the course of sequential TKI therapy. Molecular dynamics analyses of the most frequent polymutants in complex with TKIs revealed the basis of TKI resistance. Modeling of BCR-ABL1 in complex with the potent pan-BCR-ABL1 TKI ponatinib highlighted potentially effective therapeutic strategies for patients carrying these recalcitrant and complex BCR-ABL1 mutant proteins while unveiling unique mechanisms of escape to ponatinib therapy. PMID:24550512
Molecular Tools To Study Preharvest Food Safety Challenges.
Kumar, Deepak; Thakur, Siddhartha
2018-02-01
Preharvest food safety research and activities have advanced over time with the recognition of the importance and complicated nature of the preharvest phase of food production. In developed nations, implementation of preharvest food safety procedures along with strict monitoring and containment at various postharvest stages such as slaughter, processing, storage, and distribution have remarkably reduced the burden of foodborne pathogens in humans. Early detection and adequate surveillance of pathogens at the preharvest stage is of the utmost importance to ensure a safe meat supply. There is an urgent need to develop rapid, cost-effective, and point-of-care diagnostics which could be used at the preharvest stage and would complement postmortem and other quality checks performed at the postharvest stage. With newer methods and technologies, more efforts need to be directed toward developing rapid, sensitive, and specific methods for detection or screening of foodborne pathogens at the preharvest stage. In this review, we will discuss the molecular methods available for detection and molecular typing of bacterial foodborne pathogens at the farm. Such methods include conventional techniques such as endpoint PCR, real-time PCR, DNA microarray, and more advanced techniques such as matrix-assisted layer desorption ionization-time of flight mass spectrometry and whole-genome sequencing.
Quantum dots versus organic fluorophores in fluorescent deep-tissue imaging--merits and demerits.
Bakalova, Rumiana; Zhelev, Zhivko; Gadjeva, Veselina
2008-12-01
The use of fluorescence in deep-tissue imaging is rapidly expanding in last several years. The progress in fluorescent molecular probes and fluorescent imaging techniques gives an opportunity to detect single cells and even molecular targets in live organisms. The highly sensitive and high-speed fluorescent molecular sensors and detection devices allow the application of fluorescence in functional imaging. With the development of novel bright fluorophores based on nanotechnologies and 3D fluorescence scanners with high spatial and temporal resolution, the fluorescent imaging has a potential to become an alternative of the other non-invasive imaging techniques as magnetic resonance imaging, positron-emission tomography, X-ray, computing tomography. The fluorescent imaging has also a potential to give a real map of human anatomy and physiology. The current review outlines the advantages of fluorescent nanoparticles over conventional organic dyes in deep-tissue imaging in vivo and defines the major requirements to the "perfect fluorophore". The analysis proceeds from the basic principles of fluorescence and major characteristics of fluorophores, light-tissue interactions, and major limitations of fluorescent deep-tissue imaging. The article is addressed to a broad readership - from specialists in this field to university students.
Warrack, Bethanne M; Redding, Brian P; Chen, Guodong; Bolgar, Mark S
2013-05-01
PEGylation has been widely used to improve the biopharmaceutical properties of therapeutic proteins and peptides. Previous studies have used multiple analytical techniques to determine the fate of both the therapeutic molecule and unconjugated poly(ethylene glycol) (PEG) after drug administration. A straightforward strategy utilizing liquid chromatography-mass spectrometry (LC-MS) to characterize high-molecular weight PEG in biologic matrices without a need for complex sample preparation is presented. The method is capable of determining whether high-MW PEG is cleaved in vivo to lower-molecular weight PEG species. Reversed-phase chromatographic separation is used to take advantage of the retention principles of polymeric materials whereby elution order correlates with PEG molecular weight. In-source collision-induced dissociation (CID) combined with selected reaction monitoring (SRM) or selected ion monitoring (SIM) mass spectrometry (MS) is then used to monitor characteristic PEG fragment ions in biological samples. MS provides high sensitivity and specificity for PEG and the observed retention times in reversed-phase LC enable estimation of molecular weight. This method was successfully used to characterize PEG molecular weight in mouse serum samples. No change in molecular weight was observed for 48 h after dosing.
Vibrational Spectroscopy on Photoexcited Dye-Sensitized Films via Pump-Degenerate Four-Wave Mixing.
Abraham, Baxter; Fan, Hao; Galoppini, Elena; Gundlach, Lars
2018-03-01
Molecular sensitization of semiconductor films is an important technology for energy and environmental applications including solar energy conversion, photocatalytic hydrogen production, and water purification. Dye-sensitized films are also scientifically complex and interesting systems with a long history of research. In most applications, photoinduced heterogeneous electron transfer (HET) at the molecule/semiconductor interface is of critical importance, and while great progress has been made in understanding HET, many open questions remain. Of particular interest is the role of combined electronic and vibrational effects and coherence of the dye during HET. The ultrafast nature of the process, the rapid intramolecular vibrational energy redistribution, and vibrational cooling present complications in the study of vibronic coupling in HET. We present the application of a time domain vibrational spectroscopy-pump-degenerate four-wave mixing (pump-DFWM)-to dye-sensitized solid-state semiconductor films. Pump-DFWM can measure Raman-active vibrational modes that are triggered by excitation of the sample with an actinic pump pulse. Modifications to the instrument for solid-state samples and its application to an anatase TiO 2 film sensitized by a Zn-porphyrin dye are discussed. We show an effective combination of experimental techniques to overcome typical challenges in measuring solid-state samples with laser spectroscopy and observe molecular vibrations following HET in a picosecond time window. The cation spectrum of the dye shows modes that can be assigned to the linker group and a mode that is localized on the Zn-phorphyrin chromophore and that is connected to photoexcitation.
Application and Miniaturization of Linear and Nonlinear Raman Microscopy for Biomedical Imaging
NASA Astrophysics Data System (ADS)
Mittal, Richa
Current diagnostics for several disorders rely on surgical biopsy or evaluation of ex vivo bodily fluids, which have numerous drawbacks. We evaluated the potential for vibrational techniques (both linear and nonlinear Raman) as a reliable and noninvasive diagnostic tool. Raman spectroscopy is an optical technique for molecular analysis that has been used extensively in various biomedical applications. Based on demonstrated capabilities of Raman spectroscopy we evaluated the potential of the technique for providing a noninvasive diagnosis of mucopolysaccharidosis (MPS). These studies show that Raman spectroscopy can detect subtle changes in tissue biochemistry. In applications where sub-micrometer visualization of tissue compositional change is required, a transition from spectroscopy to high quality imaging is necessary. Nonlinear vibrational microscopy is sensitive to the same molecular vibrations as linear Raman, but features fast imaging capabilities. Coherent Raman scattering when combined with other nonlinear optical (NLO) techniques (like two-photon excited fluorescence and second harmonic generation) forms a collection of advanced optical techniques that provide noninvasive chemical contrast at submicron resolution. This capability to examine tissues without external molecular agents is driving the NLO approach towards clinical applications. However, the unique imaging capabilities of NLO microscopy are accompanied by complex instrument requirements. Clinical examination requires portable imaging systems for rapid inspection of tissues. Optical components utilized in NLO microscopy would then need substantial miniaturization and optimization to enable in vivo use. The challenges in designing compact microscope objective lenses and laser beam scanning mechanisms are discussed. The development of multimodal NLO probes for imaging oral cavity tissue is presented. Our prototype has been examined for ex vivo tissue imaging based on intrinsic fluorescence and SHG contrast. These studies show a potential for multiphoton compact probes to be used for real time imaging in the clinic.
Plasmonic gold nanostar for biomedical sensing
NASA Astrophysics Data System (ADS)
Liu, Yang; Yuan, Hsiangkuo; Fales, Andrew M.; Vo-Dinh, Tuan
2014-03-01
Cancer has become one of most significant death reasons and causes approximately 7.9 million human deaths worldwide each year. The challenge to detect cancer at an early stage makes cancer-related biomarkers sensing attract more and more research interest and efforts. Surface-enhanced Raman scattering (SERS) provides a promising method for various biomarkers (DNA, RNA, protein, et al.) detection due to its high sensitivity, specificity and capability for multiple analytes detection. Raman spectroscopy is a non-destructive photon-scattering technique, which provides molecule-specific information on molecular vibrational energy levels. SERS takes advantage of plasmonic effects and can enhance Raman signal up to 1015 at "hot spots". Due to its excellent sensitivity, SERS has been capable of achieving single-molecule detection limit. Local pH environment has been identified to be a potential biomarker for cancer diagnosis since solid cancer contains highly acidic environments. A near-infrared (NIR) SERS nanoprobe based on gold nanostars for pH sensing is developed for future cancer detection. Near-infrared (NIR) light is more suitable for in vivo applications because of its low attenuation rate and tissue auto fluorescence. SERS spectrum of pH reporter under various pH environments is monitored and used for pH sensing. Furthermore, density functional theory (DFT) calculation is performed to investigate Raman spectra changes with pH at the molecular level. The study demonstrates that SERS is a sensitive tool to monitor minor molecular structural changes due to local pH environment for cancer detection.
Image processing for grazing incidence fast atom diffraction
NASA Astrophysics Data System (ADS)
Debiossac, Maxime; Roncin, Philippe
2016-09-01
Grazing incidence fast atom diffraction (GIFAD, or FAD) has developed as a surface sensitive technique. Compared with thermal energies helium diffraction (TEAS or HAS), GIFAD is less sensitive to thermal decoherence but also more demanding in terms of surface coherence, the mean distance between defects. Such high quality surfaces can be obtained from freshly cleaved crystals or in a molecular beam epitaxy (MBE) chamber where a GIFAD setup has been installed allowing in situ operation. Based on recent publications by Atkinson et al. (2014) and Debiossac et al. (2014), the paper describes in detail the basic steps needed to measure the relative intensities of the diffraction spots. Care is taken to outline the underlying physical assumptions.
NASA Astrophysics Data System (ADS)
Maev, R. Gr.; Solodov, I. Yu.
2000-05-01
Classical nonlinear acoustics of solids operates with distributed material nonlinearity related to unharmonicity of molecular interaction forces. Weakening of molecular bonds in a defect area or intermittent lack of elastic coupling between the faces of a vibrating crack or unbond ("clapping") results in anomalously high local contact acoustic nonlinearity (CAN). CAN properties and spectral features are different from those of the classical analog and important to develop new acoustic NDE techniques. Three approaches to nonlinear NDE methodology have been experimentally verified: low-frequency (hundreds of Hz) vibration technique, intermediate-frequency (hundreds of kHz) standing wave and high-frequency (tens of MHz) propagation modes. Low-frequency nonlinear contact vibrations revealed multiple sub- and super-harmonics generation featuring non-monotonous (sinx/x type) spectra. Parametric instability observed in resonator with a nonlinear contact leads to the output spectrum splitting up into successive sub-harmonics as the wave amplitude increases. High-frequency experiments demonstrated abnormal increases in the third harmonic amplitude: 3 or 4 order enhancement of the 3-ω nonlinear parameter was measured for the nonlinear contact. The CAN spectral features in both acoustic and vibration modes were used for nonlinear NDE of simulated and realistic flaws in glass, metal welds, etc. The sensitivities of the techniques are compared and their practical applicability assessed.
Kress, Alla; Wang, Xiao; Ranchon, Hubert; Savatier, Julien; Rigneault, Hervé; Ferrand, Patrick; Brasselet, Sophie
2013-07-02
Fluorescence anisotropy and linear dichroism imaging have been widely used for imaging biomolecular orientational distributions in protein aggregates, fibrillar structures of cells, and cell membranes. However, these techniques do not give access to complete orientational order information in a whole image, because their use is limited to parts of the sample where the average orientation of molecules is known a priori. Fluorescence anisotropy is also highly sensitive to depolarization mechanisms such as those induced by fluorescence energy transfer. A fully excitation-polarization-resolved fluorescence microscopy imaging that relies on the use of a tunable incident polarization and a nonpolarized detection is able to circumvent these limitations. We have developed such a technique in confocal epifluorescence microscopy, giving access to new regions of study in the complex and heterogeneous molecular organization of cell membranes. Using this technique, we demonstrate morphological changes at the subdiffraction scale in labeled COS-7 cell membranes whose cytoskeleton is perturbed. Molecular orientational order is also seen to be affected by cholesterol depletion, reflecting the strong interplay between lipid-packing regions and their nearby cytoskeleton. This noninvasive optical technique can reveal local organization in cell membranes when used as a complement to existing methods such as generalized polarization. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Applications of LC-MS in PET Radioligand Development and Metabolic Elucidation
Ma, Ying; Kiesewetter, Dale O.; Lang, Lixin; Gu, Dongyu; Chen, Xiaoyuan
2013-01-01
Positron emission tomography (PET) is a very sensitive molecular imaging technique that when employed with an appropriate radioligand has the ability to quantititate physiological processes in a non-invasive manner. Since the imaging technique detects all radioactive emissions in the field of view, the presence and biological activity of radiolabeled metabolites must be determined for each radioligand in order to validate the utility of the radiotracer for measuring the desired physiological process. Thus, the identification of metabolic profiles of radiolabeled compounds is an important aspect of design, development, and validation of new radiopharmaceuticals and their applications in drug development and molecular imaging. Metabolite identification for different chemical classes of radiopharmaceuticals allows rational design to minimize the formation and accumulation of metabolites in the target tissue, either through enhanced excretion or minimized metabolism. This review will discuss methods for identifying and quantitating metabolites during the pre-clinical development of radiopharmaceuticals with special emphasis on the application of LC/MS. PMID:20540692
NASA Astrophysics Data System (ADS)
Smith, R. Scott; Matthiesen, Jesper; Kay, Bruce D.
2010-03-01
Molecular beam techniques, temperature-programmed desorption (TPD), and reflection absorption infrared spectroscopy (RAIRS) are used to explore the relationship between krypton permeation through and the self-diffusivity of supercooled liquid methanol at temperatures (100-115 K) near the glass transition temperature, Tg (103 K). Layered films, consisting of CH3OH and CD3OH, are deposited on top of a monolayer of Kr on a graphene covered Pt(111) substrate at 25 K. Concurrent Kr TPD and RAIRS spectra are acquired during the heating of the composite film to temperatures above Tg. The CO vibrational stretch is sensitive to the local molecular environment and is used to determine the supercooled liquid diffusivity from the intermixing of the isotopic layers. We find that the Kr permeation and the diffusivity of the supercooled liquid are directly and quantitatively correlated. These results validate the rare-gas permeation technique as a tool for probing the diffusivity of supercooled liquids.
Smith, R Scott; Matthiesen, Jesper; Kay, Bruce D
2010-03-28
Molecular beam techniques, temperature-programmed desorption (TPD), and reflection absorption infrared spectroscopy (RAIRS) are used to explore the relationship between krypton permeation through and the self-diffusivity of supercooled liquid methanol at temperatures (100-115 K) near the glass transition temperature, T(g) (103 K). Layered films, consisting of CH(3)OH and CD(3)OH, are deposited on top of a monolayer of Kr on a graphene covered Pt(111) substrate at 25 K. Concurrent Kr TPD and RAIRS spectra are acquired during the heating of the composite film to temperatures above T(g). The CO vibrational stretch is sensitive to the local molecular environment and is used to determine the supercooled liquid diffusivity from the intermixing of the isotopic layers. We find that the Kr permeation and the diffusivity of the supercooled liquid are directly and quantitatively correlated. These results validate the rare-gas permeation technique as a tool for probing the diffusivity of supercooled liquids.
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy.
Evans, Conor L; Potma, Eric O; Puoris'haag, Mehron; Côté, Daniel; Lin, Charles P; Xie, X Sunney
2005-11-15
Imaging living organisms with molecular selectivity typically requires the introduction of specific labels. Many applications in biology and medicine, however, would significantly benefit from a noninvasive imaging technique that circumvents such exogenous probes. In vivo microscopy based on vibrational spectroscopic contrast offers a unique approach for visualizing tissue architecture with molecular specificity. We have developed a sensitive technique for vibrational imaging of tissues by combining coherent anti-Stokes Raman scattering (CARS) with video-rate microscopy. Backscattering of the intense forward-propagating CARS radiation in tissue gives rise to a strong epi-CARS signal that makes in vivo imaging possible. This substantially large signal allows for real-time monitoring of dynamic processes, such as the diffusion of chemical compounds, in tissues. By tuning into the CH(2) stretching vibrational band, we demonstrate CARS imaging and spectroscopy of lipid-rich tissue structures in the skin of a live mouse, including sebaceous glands, corneocytes, and adipocytes, with unprecedented contrast at subcellular resolution.
Direct Detection Doppler Lidar for Spaceborne Wind Measurement
NASA Technical Reports Server (NTRS)
Korb, C. Laurence; Flesia, Cristina
1999-01-01
The theory of double edge lidar techniques for measuring the atmospheric wind using aerosol and molecular backscatter is described. Two high spectral resolution filters with opposite slopes are located about the laser frequency for the aerosol based measurement or in the wings of the Rayleigh - Brillouin profile for the molecular measurement. This doubles the signal change per unit Doppler shift and improves the measurement accuracy by nearly a factor of 2 relative to the single edge technique. For the aerosol based measurement, the use of two high resolution edge filters reduces the effects of background, Rayleigh scattering, by as much as an order of magnitude and substantially improves the measurement accuracy. Also, we describe a method that allows the Rayleigh and aerosol components of the signal to be independently determined. A measurement accuracy of 1.2 m/s can be obtained for a signal level of 1000 detected photons which corresponds to signal levels in the boundary layer. For the molecular based measurement, we describe the use of a crossover region where the sensitivity of a molecular and aerosol-based measurement are equal. This desensitizes the molecular measurement to the effects of aerosol scattering and greatly simplifies the measurement. Simulations using a conical scanning spaceborne lidar at 355 nm give an accuracy of 2-3 m/s for altitudes of 2-15 km for a 1 km vertical resolution, a satellite altitude of 400 km, and a 200 km x 200 km spatial.
Sideband-Separating, Millimeter-Wave Heterodyne Receiver
NASA Technical Reports Server (NTRS)
Ward, John S.; Bumble, Bruce; Lee, Karen A.; Kawamura, Jonathan H.; Chattopadhyay, Goutam; Stek, paul; Stek, Paul
2010-01-01
Researchers have demonstrated a submillimeter-wave spectrometer that combines extremely broad bandwidth with extremely high sensitivity and spectral resolution to enable future spacecraft to measure the composition of the Earth s troposphere in three dimensions many times per day at spatial resolutions as high as a few kilometers. Microwave limb sounding is a proven remote-sensing technique that measures thermal emission spectra from molecular gases along limb views of the Earth s atmosphere against a cold space background.
Nanoantenna-Enhanced Infrared Spectroscopic Chemical Imaging.
Kühner, Lucca; Hentschel, Mario; Zschieschang, Ute; Klauk, Hagen; Vogt, Jochen; Huck, Christian; Giessen, Harald; Neubrech, Frank
2017-05-26
Spectroscopic infrared chemical imaging is ideally suited for label-free and spatially resolved characterization of molecular species, but often suffers from low infrared absorption cross sections. Here, we overcome this limitation by utilizing confined electromagnetic near-fields of resonantly excited plasmonic nanoantennas, which enhance the molecular absorption by orders of magnitude. In the experiments, we evaporate microstructured chemical patterns of C 60 and pentacene with nanometer thickness on top of homogeneous arrays of tailored nanoantennas. Broadband mid-infrared spectra containing plasmonic and vibrational information were acquired with diffraction-limited resolution using a two-dimensional focal plane array detector. Evaluating the enhanced infrared absorption at the respective frequencies, spatially resolved chemical images were obtained. In these chemical images, the microstructured chemical patterns are only visible if nanoantennas are used. This confirms the superior performance of our approach over conventional spectroscopic infrared imaging. In addition to the improved sensitivity, our technique provides chemical selectivity, which would not be available with plasmonic imaging that is based on refractive index sensing. To extend the accessible spectral bandwidth of nanoantenna-enhanced spectroscopic imaging, we employed nanostructures with dual-band resonances, providing broadband plasmonic enhancement and sensitivity. Our results demonstrate the potential of nanoantenna-enhanced spectroscopic infrared chemical imaging for spatially resolved characterization of organic layers with thicknesses of several nanometers. This is of potential interest for medical applications which are currently hampered by state-of-art infrared techniques, e.g., for distinguishing cancerous from healthy tissues.
Wuethrich, Alain; Sina, Abu Ali Ibn; Ahmed, Mostak; Lin, Ting-Yun; Carrascosa, Laura G; Trau, Matt
2018-06-14
Interfacial biosensing performs the detection of biomolecules at the bare-metal interface for disease diagnosis by comparing how biological species derived from patients and healthy individuals interact with bare metal surfaces. This technique retrieves clinicopathological information without complex surface functionalisation which is a major limitation of conventional techniques. However, it is still challenging to detect subtle molecular changes by interfacial biosensing, and the detection often requires prolonged sensing times due to the slow diffusion process of the biomolecules towards the sensor surface. Herein, we report on a novel strategy for interfacial biosensing which involves in situ electrochemical detection under the action of an electric field-induced nanoscopic flow at nanometre distance to the sensing surface. This nanomixing significantly increases target adsorption, reduces sensing time, and enables the detection of small molecular changes with enhanced sensitivity. Using a multiplex electrochemical microdevice that enables nanomixing and in situ label-free electrochemical detection, we demonstrate the detection of multiple cancer biomarkers on the same device. We present data for the detection of aberrant phosphorylation in the EGFR protein and hypermethylation in the EN1 gene region. Our method significantly shortens the assay period (from 40 min and 20 min to 3 minutes for protein and DNA, respectively), increases the sensitivity by up to two orders of magnitude, and improves detection specificity.
Wang, Bo; Han, Soe-Soe; Cho, Cho; Han, Jin-Hee; Cheng, Yang; Lee, Seong-Kyun; Galappaththy, Gawrie N. L; Thimasarn, Krongthong; Soe, Myat Thu; Oo, Htet Wai; Kyaw, Myat Phone
2014-01-01
Asymptomatic infection is an important obstacle for controlling disease in countries where malaria is endemic. Because asymptomatic carriers do not seek treatment for their infections, they can have high levels of gametocytes and constitute a reservoir available for new infection. We employed a sample pooling/PCR-based molecular detection strategy for screening malaria infection in residents from areas of Myanmar where malaria is endemic. Blood samples (n = 1,552) were collected from residents in three areas of malaria endemicity (Kayin State, Bago, and Tanintharyi regions) of Myanmar. Two nested PCR and real-time PCR assays showed that asymptomatic infection was detected in about 1.0% to 9.4% of residents from the surveyed areas. The sensitivities of the two nested PCR and real-time PCR techniques were higher than that of microscopy examination (sensitivity, 100% versus 26.4%; kappa values, 0.2 to 0.5). Among the three regions, parasite-positive samples were highly detected in subjects from the Bago and Tanintharyi regions. Active surveillance of residents from regions of intense malaria transmission would reduce the risk of morbidity and mitigate transmission to the population in these areas of endemicity. Our data demonstrate that PCR-based molecular techniques are more efficient than microscopy for nationwide surveillance of malaria in countries where malaria is endemic. PMID:24648557
RNAi screen for rapid therapeutic target identification in leukemia patients
Tyner, Jeffrey W.; Deininger, Michael W.; Loriaux, Marc M.; Chang, Bill H.; Gotlib, Jason R.; Willis, Stephanie G.; Erickson, Heidi; Kovacsovics, Tibor; O'Hare, Thomas; Heinrich, Michael C.; Druker, Brian J.
2009-01-01
Targeted therapy has vastly improved outcomes in certain types of cancer. Extension of this paradigm across a broad spectrum of malignancies will require an efficient method to determine the molecular vulnerabilities of cancerous cells. Improvements in sequencing technology will soon enable high-throughput sequencing of entire genomes of cancer patients; however, determining the relevance of identified sequence variants will require complementary functional analyses. Here, we report an RNAi-assisted protein target identification (RAPID) technology that individually assesses targeting of each member of the tyrosine kinase gene family. We demonstrate that RAPID screening of primary leukemia cells from 30 patients identifies targets that are critical to survival of the malignant cells from 10 of these individuals. We identify known, activating mutations in JAK2 and K-RAS, as well as patient-specific sensitivity to down-regulation of FLT1, CSF1R, PDGFR, ROR1, EPHA4/5, JAK1/3, LMTK3, LYN, FYN, PTK2B, and N-RAS. We also describe a previously undescribed, somatic, activating mutation in the thrombopoietin receptor that is sensitive to down-stream pharmacologic inhibition. Hence, the RAPID technique can quickly identify molecular vulnerabilities in malignant cells. Combination of this technique with whole-genome sequencing will represent an ideal tool for oncogenic target identification such that specific therapies can be matched with individual patients. PMID:19433805
Cano, I; Ferro, P; Alonso, M C; Bergmann, S M; Römer-Oberdörfer, A; Garcia-Rosado, E; Castro, D; Borrego, J J
2007-01-01
The development and evaluation of a protocol based on polymerase chain reaction (PCR) and nucleic acid hybridization techniques for the specific detection of lymphocystis disease virus (LCDV) in several marine fish species. The pair of primers for PCR, OBL3 and OBL4, was designed based on published nucleotide sequence (LCDV-1) and amplifies a fragment within the major capsid protein. The sensitivity was evaluated using DNA from purified viral particles, as well as from cells inoculated with several viral concentrations. The PCR combined with slot blot was the most sensitive methodology, detecting 2.5 ng of viral DNA. Using this methodology LCDV was detected at 5 days postinoculation from SAF-1 cells initially inoculated with 10(-5) TCID(50) ml(-1). The combination of PCR with membrane hybridization has also been proved to be adequate to detect LCDV from apparently healthy carriers by means of caudal fin sample analysis. This asymptomatic infection was also demonstrated by classical virological methods (cell culture and immunoblot). The protocol described in this study allows the specific detection of LCDV, both in cell cultures and in fin homogenates from asymptomatic fish. The detection of asymptomatic carriers by a rapid molecular method using caudal fin sampling, which does not imply animal killing, could be an important tool to control epizootics caused by LCDV, as fish could be analysed before their introduction and/or mobilization in farm facilities.
Wang, Jiaqi; Fang, Ruizhe; Wang, Lu; Chen, Guang; Wang, Hongzhi; Wang, Zhichao; Zhao, Danfeng; Pavlov, Valentin N; Kabirov, Ildar; Wang, Ziqi; Guo, Pengyu; Peng, Li; Xu, Wanhai
2018-06-27
Emerging novel optical imaging techniques with cancer-specific molecular imaging agents offer a powerful and promising platform for cancer detection and resection. White-light cystoscopy and random bladder biopsies remain the most appropriate but nonetheless suboptimal diagnostic technique for bladder cancer, which is associated with high morbidity and recurrence. However, white-light cystoscopy has intrinsic shortcomings. Although current optical imaging technologies hold great potential for improved diagnostic accuracy, there are few imaging agents for specific molecular targeting. Carbonic anhydrase IX (CAIX) plays a pivotal role in tumorigenesis and tumor progression with potential value as an imaging target. Here, we investigated the feasibility of CAIX as a target and validated the diagnostic performance and significance of CAIX as an imaging agent. We first analyzed the data from The Cancer Genome Atlas (TCGA). Pairs of samples comprising bladder cancer and adjacent normal tissue were collected. All tissue samples were used for real-time PCR and immunohistochemistry to compare CAIX expression in normal and cancer tissue. Using blue-light cystoscopy, we observed the optical distribution of fluorescently labeled CAIX antibody in freshly excised human bladders and obtained random bladder biopsies to assess sensitivity and specificity. The TCGA data revealed that CAIX expression was significantly higher in bladder cancer specimens than in normal tissue. The outcome was similar in quantitative real-time PCR analysis. In immunohistochemical analysis, bladder cancer specimens classified in four pathological subtypes presented a variety of positive staining intensities, whereas no benign specimens showed CAIX staining. Using blue-light cystoscopy, we distinguished bladder cancers that were mainly papillary, some variants of urothelial carcinoma, and less carcinoma in situ, from benign tissue, despite the presence of suspicious-appearing mucosa. The sensitivity and specificity for CAIX-targeted imaging were 88.00% and 93.75%, respectively. CAIX-targeted molecular imaging could be a feasible and adaptive alternative approach for the accurate diagnosis and complete resection of bladder cancer. © 2018 The Author(s). Published by S. Karger AG, Basel.
Peñalber, Chariz Y; Grenoble, Zlata; Baker, Gary A; Baldelli, Steven
2012-04-21
Advancement in the field of ionic liquid technology requires a comprehensive understanding of their surface properties, as a wide range of chemical reactions occur mainly at interfaces. As essential media currently used in several technological applications, their accurate molecular level description at the gas-liquid interface is of utmost importance. Due to the high degree of chemical information provided in the vibrational spectrum, vibrational spectroscopy gives the most detailed model for molecular structure. The inherently surface-sensitive technique, sum frequency generation (SFG) spectroscopy, in combination with bulk-sensitive vibrational spectroscopic techniques such as FTIR and Raman, has been used in this report to characterize the surface of cyano-containing ionic liquids, such as [BMIM][SCN], [BMIM][DCA], [BMIM][TCM] and [EMIM][TCB] at the gas-liquid interface. By structural variation of the anion while keeping the cation constant, emphasis on the molecular arrangement of the anion at the gas-liquid interface is reported, and its subsequent role (if any) in determining the surface molecular orientation of the cation. Vibrational modes seen in the C-H stretching region revealed the presence of the cation at the gas-liquid interface. The cation orientation is independent of the type of cyano-containing anion, however, a similar arrangement at the surface as reported in previous studies was found, with the imidazolium ring lying flat at the surface, and the alkyl chains pointing towards the gas phase. SFG results show that all three anions of varying symmetry, namely, [DCA](-) (C(2v)), [TCM](-)(D(3h)) and [TCB](-) (T(d)) in ionic liquids [BMIM]DCA], [BMIM][TCM] and [EMIM][TCB] are significantly tilted from the surface plane, while the linear [SCN](-) in [BMIM][SCN] exhibited poor ordering, as seen in the absence of its C-N stretching mode in the SFG vibrational spectra. This journal is © the Owner Societies 2012
Cismesia, Adam P.; Bailey, Laura S.; Bell, Matthew R.; Tesler, Larry F.; Polfer, Nicolas C.
2016-01-01
The detailed chemical information contained in the vibrational spectrum of a cryogenically cooled analyte would, in principle, make infrared (IR) ion spectroscopy a gold standard technique for molecular identification in mass spectrometry. Despite this immense potential, there are considerable challenges in both instrumentation and methodology to overcome before the technique is analytically useful. Here, we discuss the promise of IR ion spectroscopy for small molecule analysis in the context of metabolite identification. Experimental strategies to address sensitivity constraints, poor overall duty cycle, and speed of the experiment are intimately tied to the development of a mass-selective cryogenic trap. Therefore, the most likely avenues for success, in the authors? opinion, are presented here, alongside alternative approaches and some thoughts on data interpretation. PMID:26975370
Analysis of low molecular weight compounds by MALDI-FTICR-MS.
Wang, Hao-Yang; Chu, Xu; Zhao, Zhi-Xiong; He, Xiao-Shuang; Guo, Yin-Long
2011-05-15
This review focuses on recent applications of matrix-assisted laser desorption ionization-Fourier-transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) in qualitative and quantitative analysis of low molecular weight compounds. The scope of the work includes amino acids, small peptides, mono and oligosaccharides, lipids, metabolic compounds, small molecule phytochemicals from medicinal herbs and even the volatile organic compounds from tobacco. We discuss both direct analysis and analysis following derivatization. In addition we review sample preparation strategies to reduce interferences in the low m/z range and to improve sensitivities by derivatization with charge tags. We also present coupling of head space techniques with MALDI-FTICR-MS. Furthermore, omics analyses based on MALDI-FTICR-MS were also discussed, including proteomics, metabolomics and lipidomics, as well as the relative MS imaging for bio-active low molecular weight compounds. Finally, we discussed the investigations on dissociation/rearrangement processes of low molecular weight compounds by MALDI-FTICR-MS. Copyright © 2011 Elsevier B.V. All rights reserved.
Functional optical coherence tomography: principles and progress
NASA Astrophysics Data System (ADS)
Kim, Jina; Brown, William; Maher, Jason R.; Levinson, Howard; Wax, Adam
2015-05-01
In the past decade, several functional extensions of optical coherence tomography (OCT) have emerged, and this review highlights key advances in instrumentation, theoretical analysis, signal processing and clinical application of these extensions. We review five principal extensions: Doppler OCT (DOCT), polarization-sensitive OCT (PS-OCT), optical coherence elastography (OCE), spectroscopic OCT (SOCT), and molecular imaging OCT. The former three have been further developed with studies in both ex vivo and in vivo human tissues. This review emphasizes the newer techniques of SOCT and molecular imaging OCT, which show excellent potential for clinical application but have yet to be well reviewed in the literature. SOCT elucidates tissue characteristics, such as oxygenation and carcinogenesis, by detecting wavelength-dependent absorption and scattering of light in tissues. While SOCT measures endogenous biochemical distributions, molecular imaging OCT detects exogenous molecular contrast agents. These newer advances in functional OCT broaden the potential clinical application of OCT by providing novel ways to understand tissue activity that cannot be accomplished by other current imaging methodologies.
Functional Optical Coherence Tomography: Principles and Progress
Kim, Jina; Brown, William; Maher, Jason R.; Levinson, Howard; Wax, Adam
2015-01-01
In the past decade, several functional extensions of optical coherence tomography (OCT) have emerged, and this review highlights key advances in instrumentation, theoretical analysis, signal processing and clinical application of these extensions. We review five principal extensions: Doppler OCT (DOCT), polarization-sensitive OCT (PS-OCT), optical coherence elastography (OCE), spectroscopic OCT (SOCT), and molecular imaging OCT. The former three have been further developed with studies in both ex vivo and in vivo human tissues. This review emphasizes the newer techniques of SOCT and molecular imaging OCT, which show excellent potential for clinical application but have yet to be well reviewed in the literature. SOCT elucidates tissue characteristics, such as oxygenation and carcinogenesis, by detecting wavelength-dependent absorption and scattering of light in tissues. While SOCT measures endogenous biochemical distributions, molecular imaging OCT detects exogenous molecular contrast agents. These newer advances in functional OCT broaden the potential clinical application of OCT by providing novel ways to understand tissue activity that cannot be accomplished by other current imaging methodologies. PMID:25951836
Merino, P; Große, C; Rosławska, A; Kuhnke, K; Kern, K
2015-09-29
Exciton creation and annihilation by charges are crucial processes for technologies relying on charge-exciton-photon conversion. Improvement of organic light sources or dye-sensitized solar cells requires methods to address exciton dynamics at the molecular scale. Near-field techniques have been instrumental for this purpose; however, characterizing exciton recombination with molecular resolution remained a challenge. Here, we study exciton dynamics by using scanning tunnelling microscopy to inject current with sub-molecular precision and Hanbury Brown-Twiss interferometry to measure photon correlations in the far-field electroluminescence. Controlled injection allows us to generate excitons in solid C60 and let them interact with charges during their lifetime. We demonstrate electrically driven single-photon emission from localized structural defects and determine exciton lifetimes in the picosecond range. Monitoring lifetime shortening and luminescence saturation for increasing carrier injection rates provides access to charge-exciton annihilation dynamics. Our approach introduces a unique way to study single quasi-particle dynamics on the ultimate molecular scale.
Xiao, Minyu; Joglekar, Suneel; Zhang, Xiaoxian; Jasensky, Joshua; Ma, Jialiu; Cui, Qingyu; Guo, L Jay; Chen, Zhan
2017-03-08
A wide variety of charge carrier dynamics, such as transport, separation, and extraction, occur at the interfaces of planar heterojunction solar cells. Such factors can affect the overall device performance. Therefore, understanding the buried interfacial molecular structure in various devices and the correlation between interfacial structure and function has become increasingly important. Current characterization techniques for thin films such as X-ray diffraction, cross section scanning electronmicroscopy, and UV-visible absorption spectroscopy are unable to provide the needed molecular structural information at buried interfaces. In this study, by controlling the structure of the hole transport layer (HTL) in a perovskite solar cell and applying a surface/interface-sensitive nonlinear vibrational spectroscopic technique (sum frequency generation vibrational spectroscopy (SFG)), we successfully probed the molecular structure at the buried interface and correlated its structural characteristics to solar cell performance. Here, an edge-on (normal to the interface) polythiophene (PT) interfacial molecular orientation at the buried perovskite (photoactive layer)/PT (HTL) interface showed more than two times the power conversion efficiency (PCE) of a lying down (tangential) PT interfacial orientation. The difference in interfacial molecular structure was achieved by altering the alkyl side chain length of the PT derivatives, where PT with a shorter alkyl side chain showed an edge-on interfacial orientation with a higher PCE than that of PT with a longer alkyl side chain. With similar band gap alignment and bulk structure within the PT layer, it is believed that the interfacial molecular structural variation (i.e., the orientation difference) of the various PT derivatives is the underlying cause of the difference in perovskite solar cell PCE.
13C-13C rotational resonance in a transmembrane peptide: A comparison of the fluid and gel phases
NASA Astrophysics Data System (ADS)
Langlais, Denis B.; Hodges, Robert S.; Davis, James H.
1999-05-01
A comparative study of two doubly 13C labeled amphiphilic transmembrane peptides was undertaken to determine the potential of rotational resonance for measuring internuclear distances through the direct dipolar coupling in the presence of motion. The two peptides, having the sequence acetyl-K2-G-L16-K2-A-amide, differed only in the position of 13C labels. The first peptide, [1-13C]leu11:[α-13C]leu12, had labels on adjacent residues, at the carbonyl of leu11 and the α carbon of leu12. The second, [1-13C]leu8:[α-13\\|C]leu11, was labeled on consecutive turns of the α-helical peptide. The internuclear distance between labeled positions of the first peptide, which for an ideal α helix has a value of 2.48 Å, is relatively independent of internal flexibility or peptide conformational change. The dipolar coupling between these two nuclei is sensitive to motional averaging by molecular reorientation, however, making this peptide ideal for investigating these motions. The internuclear distance between labels on the second peptide has an expected static ideal α-helix value of 4.6 Å, but this is sensitive to internal flexibility. In addition, the dipolar coupling between these two nuclei is much weaker because of their larger separation, making this peptide a much more difficult test of the rotational resonance technique. The dipolar couplings between the labeled nuclei of these two peptides were measured by rotational resonance in the dry peptide powders and in multilamellar dispersions with dimyristoylphosphatidylcholine in the gel phase, at -10 °C, and in the fluid phase, at 40 °C. The results for the peptide having adjacent labels can be readily interpreted in terms of a simple model for the peptide motion. The results for the second peptide show that, in the fluid phase, the motionally averaged dipolar coupling is too small to be measured by rotational resonance. Rotational resonance, rotational echo double resonance, and related techniques can be used to obtain reliable and valuable dipolar couplings in static solid and membrane systems. The interpretation of these couplings in terms of internuclear distances is straightforward in the absence of molecular motion. These techniques hold considerable promise for membrane protein structural studies under conditions, such as at low temperatures, where molecular motion does not modulate the dipolar couplings. However, a typical membrane at physiological temperatures exhibits complex molecular motions. In the absence of an accurate and detailed description of both internal and whole body molecular motions, it is unlikely that techniques of this type, which are based on extracting distances from direct internuclear dipolar couplings, can be used to study molecular structure under these conditions. Furthermore, the reduction in the strengths of the dipolar couplings by these motions dramatically reduces the useful range of distances which can be measured.
Quinone-based stable isotope probing for assessment of 13C substrate-utilizing bacteria
NASA Astrophysics Data System (ADS)
Kunihiro, Tadao; Katayama, Arata; Demachi, Toyoko; Veuger, Bart; Boschker, Henricus T. S.; van Oevelen, Dick
2015-04-01
In this study, we attempted to establish quinone-stable-isotope probing (SIP) technique to link substrate-utilizing bacterial group to chemotaxonomic group in bacterial community. To identify metabolically active bacterial group in various environments, SIP techniques combined with biomarkers have been widely utilized as an attractive method for environmental study. Quantitative approaches of the SIP technique have unique advantage to assess substrate-incorporation into bacteria. As a most major quantitative approach, SIP technique based on phospholipid-derived fatty acids (PLFA) have been applied to simultaneously assess substrate-incorporation rate into bacteria and microbial community structure. This approach is powerful to estimate the incorporation rate because of the high sensitivity due to the detection by a gas chromatograph-combustion interface-isotope ratio mass spectrometer (GC-c-IRMS). However, its phylogenetic resolution is limited by specificity of a compound-specific marker. We focused on respiratory quinone as a biomarker. Our previous study found a good correlation between concentrations of bacteria-specific PLFAs and quinones over several orders of magnitude in various marine sediments, and the quinone method has a higher resolution (bacterial phylum level) for resolving differences in bacterial community composition more than that of bacterial PLFA. Therefore, respiratory quinones are potentially good biomarkers for quantitative approaches of the SIP technique. The LC-APCI-MS method as molecular-mass based detection method for quinone was developed and provides useful structural information for identifying quinone molecular species in environmental samples. LC-MS/MS on hybrid triple quadrupole/linear ion trap, which enables to simultaneously identify and quantify compounds in a single analysis, can detect high molecular compounds with their isotope ions. Use of LC-MS/MS allows us to develop quinone-SIP based on molecular mass differences due to 13C abundance in the quinone. In this study, we verified carbon stable isotope of quinone compared with bulk carbon stable isotope of bacterial culture. Results indicated a good correlation between carbon stable isotope of quinone compared with bulk carbon stable isotope. However, our measurement conditions for detection of quinone isotope-ions incurred underestimation of 13C abundance in the quinone. The quinone-SIP technique needs further optimization for measurement conditions of LC-MS/MS.
Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.
2012-01-01
Background A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Methodology Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. Results 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Conclusion Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately. PMID:22253934
Mugasa, Claire M; Adams, Emily R; Boer, Kimberly R; Dyserinck, Heleen C; Büscher, Philippe; Schallig, Henk D H F; Leeflang, Mariska M G
2012-01-01
A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately.
Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?
Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A
2015-04-01
Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.
Evaluation of a nested-PCR for mycobacterium tuberculosis detection in blood and urine samples.
da Cruz, Heidi Lacerda Alves; de Albuquerque Montenegro, Rosana; de Araújo Lima, Juliana Falcão; da Rocha Poroca, Diogo; da Costa Lima, Juliana Figueirêdo; Maria Lapa Montenegro, Lílian; Crovella, Sergio; Charifker Schindler, Haiana
2011-01-01
The polymerase chain reaction (PCR) and its variations, such as the nested-PCR, have been described as promising techniques for rapid diagnosis of tuberculosis (TB). With the aim of evaluating the usefulness of a nested-PCR method on samples of blood and urine of patients suspected of tuberculosis we analyzed 192 clinical samples, using as a molecular target the insertion element IS6110 specific of M. tuberculosis genome. Nested-PCR method showed higher sensitivity in patients with extrapulmonary tuberculosis (47.8% and 52% in blood and urine) when compared to patients with the pulmonary form of the disease (sensitivity of 29% and 26.9% in blood and urine), regardless of the type of biological sample used. The nested-PCR is a rapid technique that, even if not showing a good sensitivity, should be considered as a helpful tool especially in the extrapulmonary cases or in cases where confirmatory diagnosis is quite difficult to be achieved by routine methods. The performance of PCR-based techniques should be considered and tested in future works on other types of biological specimens besides sputum, like blood and urine, readily obtainable in most cases. The improving of M. tuberculosis nested-PCR detection in TB affected patients will give the possibility of an earlier detection of bacilli thus interrupting the transmission chain of the disease.
NASA Astrophysics Data System (ADS)
Khodabakhsh, Amir; Johansson, Alexandra C.; Foltynowicz, Aleksandra
2015-04-01
Noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS) is a recently developed technique that utilizes phase modulation to obtain immunity to frequency-to-amplitude noise conversion by the cavity modes and yields high absorption sensitivity over a broad spectral range. We describe the principles of the technique and discuss possible comb-cavity matching solutions. We present a theoretical description of NICE-OFCS signals detected with a Fourier transform spectrometer (FTS) and validate the model by comparing it to experimental CO2 spectra around 1,575 nm. Our system is based on an Er:fiber femtosecond laser locked to a cavity and phase-modulated at a frequency equal to a multiple of the cavity free spectral range (FSR). The NICE-OFCS signal is detected by a fast-scanning FTS equipped with a high-bandwidth commercial detector. We demonstrate a simple method of passive locking of the modulation frequency to the cavity FSR that significantly improves the long-term stability of the system, allowing averaging times on the order of minutes. Using a cavity with a finesse of ~9,000, we obtain absorption sensitivity of 6.4 × 10-11 cm-1 Hz-1/2 per spectral element and concentration detection limit for CO2 of 450 ppb Hz-1/2, determined by multiline fitting.
Saha, Subhrakanti; Chen, Lee Chuin; Mandal, Mridul Kanti; Hiraoka, Kenzo
2013-03-01
This work describes the development and application of a new thermal desorption technique that makes use of the Leidenfrost phenomenon in open ion sources at atmospheric pressure for direct mass spectrometric detection of ultratrace levels of illicit, therapeutic, and stimulant drugs, toxicants, and peptides (molecular weight above 1 kDa) in their unaltered state from complex real world samples without or with minor sample pretreatment. A low temperature dielectric barrier discharge ion source was used throughout the experiments and the analytical figures of merit of this technique were investigated. Further, this desorption technique coupled with other ionization sources such as electrospray ionization (ESI) and dc corona discharge atmospheric pressure chemical ionization (APCI) in open atmosphere was also investigated. The use of the high-resolution 'Exactive Orbitrap' mass spectrometer provided unambiguous identification of trace levels of the targeted compounds from complex mixtures and background noise; the limits of detection for various small organic molecules and peptides treated with this technique were at the level of parts per trillion and 10(-9) M, respectively. The high sensitivity of the present technique is attributed to the spontaneous enrichment of analyte molecules during the slow evaporation of the solvent, as well as to the sequential desorption of molecules from complex mixtures based on their volatilities. This newly developed desorption technique is simple and fast, while molecular ions are observed as the major ions.
Brensinger, Karen; Rollman, Christopher; Copper, Christine; Genzman, Ashton; Rine, Jacqueline; Lurie, Ira; Moini, Mehdi
2016-01-01
To address the need for the forensic analysis of high explosives, a novel capillary electrophoresis mass spectrometry (CE-MS) technique has been developed for high resolution, sensitivity, and mass accuracy detection of these compounds. The technique uses perfluorooctanoic acid (PFOA) as both a micellar electrokinetic chromatography (MEKC) reagent for separation of neutral explosives and as the complexation reagent for mass spectrometric detection of PFOA-explosive complexes in the negative ion mode. High explosives that formed complexes with PFOA included RDX, HMX, tetryl, and PETN. Some nitroaromatics were detected as molecular ions. Detection limits in the high parts per billion range and linear calibration responses over two orders of magnitude were obtained. For proof of concept, the technique was applied to the quantitative analysis of high explosives in sand samples. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Recent progress in tissue optical clearing
Zhu, Dan; Larin, Kirill V; Luo, Qingming; Tuchin, Valery V
2013-01-01
Tissue optical clearing technique provides a prospective solution for the application of advanced optical methods in life sciences. This paper gives a review of recent developments in tissue optical clearing techniques. The physical, molecular and physiological mechanisms of tissue optical clearing are overviewed and discussed. Various methods for enhancing penetration of optical-clearing agents into tissue, such as physical methods, chemical-penetration enhancers and combination of physical and chemical methods are introduced. Combining the tissue optical clearing technique with advanced microscopy image or labeling technique, applications for 3D microstructure of whole tissues such as brain and central nervous system with unprecedented resolution are demonstrated. Moreover, the difference in diffusion and/or clearing ability of selected agents in healthy versus pathological tissues can provide a highly sensitive indicator of the tissue health/pathology condition. Finally, recent advances in optical clearing of soft or hard tissue for in vivo imaging and phototherapy are introduced. PMID:24348874
Biosensor-based microRNA detection: techniques, design, performance, and challenges.
Johnson, Blake N; Mutharasan, Raj
2014-04-07
The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)-attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.
Recombinase polymerase amplification applied to plant virus detection and potential implications.
Babu, Binoy; Ochoa-Corona, Francisco M; Paret, Mathews L
2018-04-01
Several isothermal techniques for the detection of plant pathogens have been developed with the advent of molecular techniques. Among them, Recombinase Polymerase Amplification (RPA) is becoming an important technique for the rapid, sensitive and cost-effective detection of plant viruses. The RPA technology has the advantage to be implemented in field-based scenarios because the method requires a minimal sample preparation, and is performed at constant low temperature (37-42 °C). The RPA technique is rapidly becoming a promising tool for use in rapid detection and further diagnostics in plant clinics and monitoring quarantine services. This paper presents a review of studies conducted using RPA for detection/diagnosis of plant viruses with either DNA genomes (Banana bunchy top virus, Bean golden yellow mosaic virus, Tomato mottle virus, Tomato yellow leaf curl virus) or RNA genomes (Little Cherry virus 2, Plum pox virus and Rose rosette virus). Copyright © 2018 Elsevier Inc. All rights reserved.
Arrays of dipolar molecular rotors in Tris(o-phenylenedioxy) cyclotriphosphazene.
Zhao, Ke; Dron, Paul I; Kaleta, Jiří; Rogers, Charles T; Michl, Josef
2014-01-01
Regular two-dimensional or three-dimensional arrays of mutually interacting dipolar molecular rotors represent a worthy synthetic objective. Their dielectric properties, including possible collective behavior, will be a sensitive function of the location of the rotors, the orientation of their axes, and the size of their dipoles. Host-guest chemistry is one possible approach to gaining fine control over these factors. We describe the progress that has been achieved in recent years using tris (o-phenylenedioxy)cyclotriphosphazene as a host and a series of rod-shaped dipolar molecular rotors as guests. Structures of both surface and bulk inclusion compounds have been established primarily by solid-state nuclear magnetic resonance (NMR) and powder X-ray diffraction (XRD) techniques. Low-temperature dielectric spectroscopy revealed rotational barriers as low as 1.5 kcal/mol, but no definitive evidence for collective behavior has been obtained so far.
Cocinero, Emilio J; Çarçabal, Pierre
2015-01-01
Although carbohydrates represent one of the most important families of biomolecules, they remain under-studied in comparison to the other biomolecular families (peptides, nucleobases). Beyond their best-known function of energy source in living systems, they act as mediator of molecular recognition processes, carrying molecular information in the so-called "sugar code," just to name one of their countless functions. Owing to their high conformational flexibility, they encode extremely rich information conveyed via the non-covalent hydrogen bonds within the carbohydrate and with other biomolecular assemblies, such as peptide subunits of proteins. Over the last decade there has been tremendous progress in the study of the conformational preferences of neutral oligosaccharides, and of the interactions between carbohydrates and various molecular partners (water, aromatic models, and peptide models), using vibrational spectroscopy as a sensitive probe. In parallel, other spectroscopic techniques have recently become available to the study of carbohydrates in the gas phase (microwave spectroscopy, IRMPD on charged species).
James, Ameh; Macdonald, Joanne
2015-01-01
Isothermal molecular diagnostics are bridging the technology gap between traditional diagnostics and polymerase chain reaction-based methods. These new techniques enable timely and accurate testing, especially in settings where there is a lack of infrastructure to support polymerase chain reaction facilities. Despite this, there is a significant lack of uptake of these technologies in developing countries where they are highly needed. Among these novel isothermal technologies, recombinase polymerase amplification (RPA) holds particular potential for use in developing countries. This rapid nucleic acid amplification approach is fast, highly sensitive and specific, and amenable to countries with a high burden of infectious diseases. Implementation of RPA technology in developing countries is critically required to assess limitations and potentials of the diagnosis of infectious disease, and may help identify impediments that prevent adoption of new molecular technologies in low resource- and low skill settings. This review focuses on approaching diagnosis of infectious disease with RPA.
NASA Astrophysics Data System (ADS)
Dutta Banik, Gourab; Maity, Abhijit; Som, Suman; Pal, Mithun; Pradhan, Manik
2018-04-01
We report on the performance of a widely tunable continuous wave mode-hop-free external-cavity quantum cascade laser operating at λ ~ 5.2 µm combined with cavity ring-down spectroscopy (CRDS) technique for high-resolution molecular spectroscopy. The CRDS system has been utilized for simultaneous and molecule-specific detection of several environmentally and bio-medically important trace molecular species such as nitric oxide, nitrous oxide, carbonyl sulphide and acetylene (C2H2) at ultra-low concentrations by probing numerous rotationally resolved ro-vibrational transitions in the mid-IR spectral region within a relatively small spectral range of ~0.035 cm-1. This continuous wave external-cavity quantum cascade laser-based multi-component CRDS sensor with high sensitivity and molecular specificity promises applications in environmental sensing as well as non-invasive medical diagnosis through human breath analysis.
Thermospheric temperature measurement technique.
NASA Technical Reports Server (NTRS)
Hueser, J. E.; Fowler, P.
1972-01-01
A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.
Blumencranz, Peter; Whitworth, Pat W; Deck, Kenneth; Rosenberg, Anne; Reintgen, Douglas; Beitsch, Peter; Chagpar, Anees; Julian, Thomas; Saha, Sukamal; Mamounas, Eleftherios; Giuliano, Armando; Simmons, Rache
2007-10-01
When sentinel node dissection reveals breast cancer metastasis, completion axillary lymph node dissection is ideally performed during the same operation. Intraoperative histologic techniques have low and variable sensitivity. A new intraoperative molecular assay (GeneSearch BLN Assay; Veridex, LLC, Warren, NJ) was evaluated to determine its efficiency in identifying significant sentinel lymph node metastases (>.2 mm). Positive or negative BLN Assay results generated from fresh 2-mm node slabs were compared with results from conventional histologic evaluation of adjacent fixed tissue slabs. In a prospective study of 416 patients at 11 clinical sites, the assay detected 98% of metastases >2 mm and 88% of metastasis greater >.2 mm, results superior to frozen section. Micrometastases were less frequently detected (57%) and assay positive results in nodes found negative by histology were rare (4%). The BLN Assay is properly calibrated for use as a stand alone intraoperative molecular test.
Kramer, Eric A; Rentschler, Mark E
2018-06-04
As minimally invasive surgical techniques progress, the demand for efficient, reliable methods for vascular ligation and tissue closure becomes pronounced. The surgical advantages of energy-based vessel sealing exceed those of traditional, compression-based ligatures in procedures sensitive to duration, foreign bodies, and recovery time alike. Although the use of energy-based devices to seal or transect vasculature and connective tissue bundles is widespread, the breadth of heating strategies and energy dosimetry used across devices underscores an uncertainty as to the molecular nature of the sealing mechanism and induced tissue effect. Furthermore, energy-based techniques exhibit promise for the closure and functional repair of soft and connective tissues in the nervous, enteral, and dermal tissue domains. A constitutive theory of molecular bonding forces that arise in response to supraphysiological temperatures is required in order to optimize and progress the use of energy-based tissue fusion. While rapid tissue bonding has been suggested to arise from dehydration, dipole interactions, molecular cross-links, or the coagulation of cellular proteins, long-term functional tissue repair across fusion boundaries requires that the reaction to thermal damage be tailored to catalyze the onset of biological healing and remodeling. In this review, we compile and contrast findings from published thermal fusion research in an effort to encourage a molecular approach to characterization of the prevalent and promising energy-based tissue bond.
Can we trust intraoperative culture results in nonunions?
Palmer, Michael P; Altman, Daniel T; Altman, Gregory T; Sewecke, Jeffrey J; Ehrlich, Garth D; Hu, Fen Z; Nistico, Laura; Melton-Kreft, Rachel; Gause, Trent M; Costerton, John W
2014-07-01
To identify the presence of bacterial biofilms in nonunions comparing molecular techniques (multiplex polymerase chain reaction and mass spectrometry, fluorescent in situ hybridization) with routine intraoperative cultures. Thirty-four patients with nonunions were scheduled for surgery and enrolled in this ongoing prospective study. Intraoperative specimens were collected from removed implants, surrounding tissue membrane, and local soft tissue followed by standard culture analysis, Ibis's second generation molecular diagnostics (Ibis Biosystems), and bacterial 16S rRNA-based fluorescence in situ hybridization (FISH). Confocal microscopy was used to visualize the tissue specimens reacted with the FISH probes, which were chosen based on the Ibis analysis. Thirty-four patient encounters were analyzed. Eight were diagnosed as infected nonunions by positive intraoperative culture results. Ibis confirmed the presence of bacteria in all 8 samples. Ibis identified bacteria in a total of 30 of 34 encounters, and these data were confirmed by FISH. Twenty-two of 30 Ibis-positive samples were culture-negative. Four samples were negative by all methods of analysis. No samples were positive by culture, but negative by molecular techniques. Our preliminary data indicate that molecular diagnostics are more sensitive for identifying bacteria than cultures in cases of bony nonunion. This is likely because of the inability of cultures to detect biofilms and bacteria previously exposed to antibiotic therapy. Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.
A fast method for detecting Cryptosporidium parvum oocysts in real world samples
NASA Astrophysics Data System (ADS)
Stewart, Shona; McClelland, Lindy; Maier, John
2005-04-01
Contamination of drinking water with pathogenic microorganisms such as Cryptosporidium has become an increasing concern in recent years. Cryptosporidium oocysts are particularly problematic, as infections caused by this organism can be life threatening in immunocompromised patients. Current methods for monitoring and analyzing water are often laborious and require experts to conduct. In addition, many of the techniques require very specific reagents to be employed. These factors add considerable cost and time to the analytical process. Raman spectroscopy provides specific molecular information on samples, and offers advantages of speed, sensitivity and low cost over current methods of water monitoring. Raman spectroscopy is an optical method that has demonstrated the capability to identify and differentiate microorganisms at the species and strain levels. In addition, this technique has exhibited sensitivities down to the single organism detection limit. We have employed Raman spectroscopy and Raman Chemical Imaging, in conjunction with chemometric techniques, to detect small numbers of oocysts in the presence of interferents derived from real-world water samples. Our investigations have also indicated that Raman Chemical Imaging may provide chemical and physiological information about an oocyst sample which complements information provided by the traditional methods. This work provides evidence that Raman imaging is a useful technique for consideration in the water quality industry.
Ruiz-García, Leonor; Cabezas, Jose Antonio; de María, Nuria; Cervera, María-Teresa
2010-01-01
Different molecular techniques have been developed to study either the global level of methylated cytosines or methylation at specific gene sequences. One of them is a modification of the Amplified Fragment Length Polymorphism (AFLP) technique that has been used to study methylation of anonymous CCGG sequences in different fungi, plant and animal species. The main variation of this technique is based on the use of isoschizomers with different methylation sensitivity (such as HpaII and MspI) as a frequent cutter restriction enzyme. For each sample, AFLP analysis is performed using both EcoRI/HpaII and EcoRI/MspI digested samples. Comparative analysis between EcoRI/HpaII and EcoRI/MspI fragment patterns allows the identification of two types of polymorphisms: (1) "Methylation-insensitive polymorphisms" that show common EcoRI/HpaII and EcoRI/MspI patterns but are detected as polymorphic amplified fragments among samples; and (2) "Methylation-sensitive polymorphisms" that are associated with amplified fragments differing in their presence or absence or in their intensity between EcoRI/HpaII and EcoRI/MspI patterns. This chapter describes a detailed protocol of this technique and discusses modifications that can be applied to adjust the technology to different species of interest.
Sensitive coating for water vapors detection based on thermally sputtered calcein thin films.
Kruglenko, I; Shirshov, Yu; Burlachenko, J; Savchenko, A; Kravchenko, S; Manera, M G; Rella, R
2010-09-15
In this paper the adsorption properties of thermally sputtered calcein thin films towards water and other polar molecules vapors are studied by different characterization techniques: quartz crystal microbalance, surface plasmon resonance and visible spectroscopy. Sensitivity of calcein thin films to water vapors resulted much higher as compared with those of a number of dyes whose structure was close to that of calcein. All types of sensors with calcein coatings have demonstrated linear concentration dependences in the wide range of water vapor pressure from low concentrations up to 27,000 ppm (close to saturation). At higher concentrations of water vapor all sensors demonstrate the abrupt increase of the response (up to two orders). A theoretical model is advanced explaining the adsorption properties of calcein thin films taking into account their chemical structure and peculiarities of molecular packing. The possibility of application of thermally sputtered calcein films in sensing technique is discussed. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Exploitation of molecular profiling techniques for GM food safety assessment.
Kuiper, Harry A; Kok, Esther J; Engel, Karl-Heinz
2003-04-01
Several strategies have been developed to identify unintended alterations in the composition of genetically modified (GM) food crops that may occur as a result of the genetic modification process. These include comparative chemical analysis of single compounds in GM food crops and their conventional non-GM counterparts, and profiling methods such as DNA/RNA microarray technologies, proteomics and metabolite profiling. The potential of profiling methods is obvious, but further exploration of specificity, sensitivity and validation is needed. Moreover, the successful application of profiling techniques to the safety evaluation of GM foods will require linked databases to be built that contain information on variations in profiles associated with differences in developmental stages and environmental conditions.
Advances in Mid-Infrared Spectroscopy for Chemical Analysis
NASA Astrophysics Data System (ADS)
Haas, Julian; Mizaikoff, Boris
2016-06-01
Infrared spectroscopy in the 3-20 μm spectral window has evolved from a routine laboratory technique into a state-of-the-art spectroscopy and sensing tool by benefitting from recent progress in increasingly sophisticated spectra acquisition techniques and advanced materials for generating, guiding, and detecting mid-infrared (MIR) radiation. Today, MIR spectroscopy provides molecular information with trace to ultratrace sensitivity, fast data acquisition rates, and high spectral resolution catering to demanding applications in bioanalytics, for example, and to improved routine analysis. In addition to advances in miniaturized device technology without sacrificing analytical performance, selected innovative applications for MIR spectroscopy ranging from process analysis to biotechnology and medical diagnostics are highlighted in this review.
[MALDI-TOF mass spectrometry in the investigation of large high-molecular biological compounds].
Porubl'ova, L V; Rebriiev, A V; Hromovyĭ, T Iu; Minia, I I; Obolens'ka, M Iu
2009-01-01
MALDI-TOF (Matrix-Assisted Laser Desorption/Ionization Time-of-Flight) mass spectrometry has become, in the recent years, a tool of choice for analyses of biological polymers. The wide mass range, high accuracy, informativity and sensitivity make it a superior method for analysis of all kinds of high-molecular biological compounds including proteins, nucleic acids and lipids. MALDI-TOF-MS is particularly suitable for the identification of proteins by mass fingerprint or microsequencing. Therefore it has become an important technique of proteomics. Furthermore, the method allows making a detailed analysis of post-translational protein modifications, protein-protein and protein-nucleic acid interactions. Recently, the method was also successfully applied to nucleic acid sequencing as well as screening for mutations.
Issues in contemporary and potential future molecular diagnostics for dengue.
Sekaran, Shamala Devi; Soe, Hui Jen
2017-03-01
Dengue has been the most common arbovirus infection worldwide with 2.5 billion people living in over 100 endemic tropical and subtropical regions. Due to the high number of asymptomatic cases and the signs and symptoms being rather unspecific, dengue cases are often under-reported and might influence dengue surveillance programs. Therefore, a rapid, easy to use, inexpensive, and highly sensitive and specific diagnostic tool is essential for early and accurate diagnosis to ease the clinical management of patients as well as for the development of new interventions. Areas covered: This report discusses the contemporary dengue diagnostic tool, mainly from the aspect of molecular diagnosis where an overview of several nuclei acid amplification tests has been included. Potential molecular diagnostic tools such as biosensor and microarray are also discussed in this report. Expert commentary: Rapidness and accuracy in terms of sensitivity and specificity is imperative in dengue diagnosis for both clinical management and surveillance of dengue to ensure early treatment and corrective control measures can be carried out. In the next five years it is expected that there will be newer tests developed using not only the lateral flow techniques but more specifically biosensors and nanotechnology. These new technologies will have to be validated with the appropriate number and category of samples and to address the issue of cross-reactivity.
Shi, Huijie; Zhao, Jinzhi; Wang, Yingling; Zhao, Guohua
2016-07-15
A highly selective and sensitive photoelectrochemical (PEC) sensor was fabricated for fast and convenient detection of PCB 101 in environmental water samples with a low detection limit of 1.0×10(-14)molL(-1) based on single crystalline TiO2 nanorods (NRs). By integration with molecular imprinting (MI) technique, the PEC sensor's selectivity towards PCB 101 was significantly improved, so that the interference caused by 100-fold excess of PCB 126 and PCB 77 which had similar structure with PCB 101 was below 37%, not to mention other coexisted pollutants. This high selectivity could be attributed to the high-quality expression of the molecular imprinting sites on the rigid and smooth surface of single crystalline TiO2 NRs on which PCB 101 could be selectively and preferentially adsorbed. The oriented and multiple halogen bonds formed between PCB 101 and the molecular imprinting sites played a critical role in improving the recognition ability of the PEC sensor. Meanwhile, the one dimensional nanorods structure of TiO2 was beneficial for the efficient separation of photogenerated electrons and holes, leading to enhanced photocurrent response and further improving the sensitivity of the PEC sensor. Copyright © 2016 Elsevier B.V. All rights reserved.
Zou, Dongqing; Zhao, Wenkai; Cui, Bin; Li, Dongmei; Liu, Desheng
2018-01-17
A theoretical investigation of the gas detection performance of manganese(ii) phthalocyanine (MnPc) molecular junctions for six different gases (NO, CO, O 2 , CO 2 , NO 2 , and NH 3 ) is executed through a non-equilibrium Green's function technique in combination with spin density functional theory. Herein, we systematically studied the adsorption structural configurations, the adsorption energy, the charge transfer, and the spin transport properties of the MnPc molecular junctions with these gas adsorbates. Remarkably, NO adsorption can achieve an off-state of the Mn spin; this may be an effective measure to switch the molecular spin. In addition, our results indicate that by measuring spin filter efficiency and the changes in total current through the molecular junctions, the CO, NO, O 2 , and NO 2 gas molecules can be detected selectively. However, the CO 2 and NH 3 gas adsorptions are difficult to be detected due to weak van der Waals interaction between these two gases and central Mn atom. Our findings provide important clues to the application of nanosensors for highly sensitive and selective based on MnPc molecular junction systems.
Nyvold, Charlotte Guldborg
2015-05-01
Hematological malignancies are a heterogeneous group of cancers with respect to both presentation and prognosis, and many subtypes are nowadays associated with aberrations that make up excellent molecular targets for the quantification of minimal residual disease. The quantitative PCR methodology is outstanding in terms of sensitivity, specificity and reproducibility and thus an excellent choice for minimal residual disease assessment. However, the methodology still has pitfalls that should be carefully considered when the technique is integrated in a clinical setting.
NASA Astrophysics Data System (ADS)
Hartinger, Klaus; Bartels, Randy A.
2008-01-01
We demonstrate a single-shot measurement of the transient phase modulation due to field free molecular alignment at the revival times of a rotational wave packet. The wave packet is excited by an arbitrarily polarized ultrashort laser pulse in CO2 at room temperature. With this technique the time dependence along the eigenpolarization directions of the linear susceptibility tensor, i.e., the time dependence of its principle components, can be directly observed with high sensitivity.
New imaging systems in nuclear medicine. Final report, January 1, 1993--December 31, 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-12-31
The aim of this program has been to improve the performance of positron emission tomography (PET) to achieve high resolution with high sensitivity. Towards this aim, the authors have carried out the following studies: (1) explored new techniques for detection of annihilation radiation including new detector materials and system geometries, specific areas that they have studied include--exploration of factors related to resolution and sensitivity of PET instrumentation including geometry, detection materials and coding, and the exploration of technique to improve the image quality by use of depth of interaction and increased sampling; (2) complete much of the final testing ofmore » PCR-II, an analog-coded cylindrical positron tomograph, developed and constructed during the current funding period; (3) developed the design of a positron microtomograph with mm resolution for quantitative studies in small animals, a single slice version of this device has been designed and studied by use of computer simulation; (4) continued and expanded the program of biological studies in animal models. Current studies have included imaging of animal models of Parkinson`s and Huntington`s disease and cancer. These studies have included new radiopharmaceuticals and techniques involving molecular biology.« less
NASA Astrophysics Data System (ADS)
Kwong, Tiffany C.; Nouizi, Farouk; Sampathkumaran, Uma; Zhu, Yue; Alam, Maksudul M.; Gulsen, Gultekin
2015-03-01
Fluorescent tomography has been hindered by poor tissue penetration and weak signal which results in poor spatial resolution and quantification accuracy. Recently, it has been reported that activatable temperature responsive fluorescent probes which respond to focused ultrasound heating can improve the resolution and quantification of fluorescent tomography in deep tissue. This has lead to a new imaging modality, "Temperature-modulated fluorescent tomography." This technique relies on activatable thermo-sensitive fluorescent nanocapsules for whose fluorescence quantum efficiency is temperature dependent. Within a 4-5° C temperature range, the fluorescent signal increase more than 10-fold. In this molecular probe, Indocyanine Green (ICG) is encapsulated inside the core of a thermo-reversible pluronic micelle. Here we show the fluorescence response and temperature range of the nanocapsules which have been optimized for a higher temperature range to be used for in vivo animal imaging. We report on the feasibility of these temperature-sensitive reversible nanocapsules for in vivo applications by studying the pharmacokinetics in a subcutaneous mouse tumor model in vivo.
SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Xiaoliang Sunney
Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly,more » even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.« less
Paul, Bijan Kumar; Samanta, Anuva; Guchhait, Nikhil
2010-05-13
A simple intramolecular charge transfer (ICT) compound, 5-(4-dimethylamino-phenyl)-penta-2,4-dienoic acid methyl ester (DPDAME), has been documented to be a potential molecular reporter for probing microheterogeneous environments of a model transport protein bovine serum albumin (BSA) using spectroscopic techniques. Meteoric modifications to the emission profile of DPDAME upon addition of BSA come out to be a result of its binding to hydrophobic subdomain IIA. The highly polarity-sensitive ICT emission of DPDAME is found to be a proficient extrinsic molecular reporter for efficient mapping of native, intermediate, unfolded, and refolded states of the protein. Experimental data coupled with a reinforcing support from theoretical simulation using CHARMM22 software confirm the binding site of the probe to be the subdomain IIA of BSA, while FRET study reveals a remarkably close approach of our extrinsic molecular reporter to Trp-212 (in domain IIA): the distance between DPDAME and Trp-212 is 1.437 nm. The caliber of DPDAME as an external fluorescence marker also extends to the depiction of protein-surfactant (BSA-SDS) interaction to commendable fruition. Additionally, the protective action of small amounts of SDS on urea-denatured protein is documented by polarity-sensitive ICT emission of the probe. The present study also reflects the enhancement of the stability of BSA with respect to chemically induced denaturation by urea as a result of binding to the probe DPDAME.
Papper, V; Medvedeva, N; Fishov, I; Likhtenshtein, G I
2000-01-01
We proposed a new method for the study of molecular dynamics and fluidity of the living and model biomembranes and surface systems. The method is based on the measurements of the sensitized photoisomerization kinetics of a photochrome probe. The cascade triplet cis-trans photoisomerization of the excited stilbene derivative sensitized with the excited triplet Erythrosin B has been studied in a model liposome membrane. The photoisomerization reaction is depressed with nitroxide radicals quenching the excited triplet state of the sensitizer. The enhanced fluorescence polarization of the stilbene probe incorporated into liposome membranes indicates that the stilbene molecules are squeezed in a relatively viscous media of the phospholipids. Calibration of the "triple" cascade system is based on a previously proposed method that allows the measurement of the product of the quenching rate constant and the sensitizer's triplet lifetime, as well as the quantitative detection of the nitroxide radicals in the vicinity of the membrane surface. The experiment was conducted using the constant-illumination fluorescence technique. Sensitivity of the method using a standard commercial spectrofluorimeter is about 10(-12) mol of fluorescence molecules per sample and can be improved using an advanced fluorescence technique. The minimal local concentration of nitroxide radicals or any other quenchers being detected is about 10(-5) M. This method enables the investigation of any chemical and biological surface processes of microscopic scale when the minimal volume is about 10(-3) microL or less.
Piezoelectric detection of bilirubin based on bilirubin-imprinted titania film electrode.
Yang, Zhengpeng; Yan, Jinlong; Zhang, Chunjing
2012-02-01
A novel quartz crystal microbalance (QCM) sensor with a high selectivity and sensitivity has been developed for bilirubin determination, based on the modification of bilirubin-imprinted titania film onto a quartz crystal by molecular imprinting and surface sol-gel techniques. The performance of the developed bilirubin biosensor was evaluated and the results indicated that a sensitive bilirubin biosensor could be fabricated. The obtained bilirubin biosensor presents high-selectivity monitoring of bilirubin, better reproducibility, shorter response time (30 min), wider linear range (0.1-50 μM), and lower detection limit (0.05 μM). The analytical application of the bilirubin biosensor confirms the feasibility of bilirubin determination in serum sample. Copyright © 2011 Elsevier Inc. All rights reserved.
Slawinski, Janusz; Gorski, Zbigniew
2008-05-01
Using an ultrasensitive CCD camera, an extremely low light intensity from the acupuncture-sensitive point JG4 at the left hand was recorded. As the intensity of the light was very weak and the time of electrostimulation exceeded the recommended period, the quality of biophoton images was poor. Chemiluminescent and fluorescent hydrophilic, hydrophobic and amphyphilic molecular probes were used to: (i) ensure penetration of probes into skin, (ii) enhance the intensity of BP emission, (iii) shorten time and (iv) obtain information about mechanisms of biophotons generation in EAP-sensitive points and channels. The results obtained partially fulfilled expectations and indicate on the necessity to elaborate special techniques of probes deposition on the skin.
Biomedical application of MALDI mass spectrometry for small-molecule analysis.
van Kampen, Jeroen J A; Burgers, Peter C; de Groot, Ronald; Gruters, Rob A; Luider, Theo M
2011-01-01
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is an emerging analytical tool for the analysis of molecules with molar masses below 1,000 Da; that is, small molecules. This technique offers rapid analysis, high sensitivity, low sample consumption, a relative high tolerance towards salts and buffers, and the possibility to store sample on the target plate. The successful application of the technique is, however, hampered by low molecular weight (LMW) matrix-derived interference signals and by poor reproducibility of signal intensities during quantitative analyses. In this review, we focus on the biomedical application of MALDI-MS for the analysis of small molecules and discuss its favorable properties and its challenges as well as strategies to improve the performance of the technique. Furthermore, practical aspects and applications are presented. © 2010 Wiley Periodicals, Inc.
Smith, Kirsty F; de Salas, Miguel; Adamson, Janet; Rhodes, Lesley L
2014-03-07
The identification of toxin-producing dinoflagellates for monitoring programmes and bio-compound discovery requires considerable taxonomic expertise. It can also be difficult to morphologically differentiate toxic and non-toxic species or strains. Various molecular methods have been used for dinoflagellate identification and detection, and this study describes the development of eight real-time polymerase chain reaction (PCR) assays targeting the large subunit ribosomal RNA (LSU rRNA) gene of species from the genera Gymnodinium, Karenia, Karlodinium, and Takayama. Assays proved to be highly specific and sensitive, and the assay for G. catenatum was further developed for quantification in response to a bloom in Manukau Harbour, New Zealand. The assay estimated cell densities from environmental samples as low as 0.07 cells per PCR reaction, which equated to three cells per litre. This assay not only enabled conclusive species identification but also detected the presence of cells below the limit of detection for light microscopy. This study demonstrates the usefulness of real-time PCR as a sensitive and rapid molecular technique for the detection and quantification of micro-algae from environmental samples.
Kinetics of coal conversion to soluble products. Final technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, J.W.
1994-04-12
The objectives of this work are (1) to measure the kinetics of the conversion of coals to soluble products under model liquefaction conditions using GPS techniques to count the number of bonds broken; (2) to analyze these data using kinetic schemes based on the behavior of crosslinked macromolecular networks. The product was Soxhlet extracted with pyridine until the pyridine solution was clear. A gel permeation chromatogram of the pyridine soluble is shown in Figure 2A. The improved mass sensitive detector system requires only about 500 ng to acquire a chromatogram having fairly good S/N ratio. Apparently, no disturbance is causedmore » by the remaining tetralin and naphthalene formed by dehydrogenation of tetralin. These seriously affect the lower molecular weight region when IR or UV detectors are used. It is a notable advantage of the mass sensitive detector that suitable adjustment of the nebulizer and of the evaporator completely suppressed the contribution of solvent to the chromatogram. The molecular weight distribution of liquefaction product appears to be almost unimodal if the small shoulder at the lower elution volume side is neglected.« less
Inductively coupled plasma mass spectrometry (ICP MS): a versatile tool.
Ammann, Adrian A
2007-04-01
Inductively coupled plasma (ICP) mass spectrometry (MS) is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and matrices introduced by a variety of specialized devices. Outstanding properties such as high sensitivity (ppt-ppq), relative salt tolerance, compound-independent element response and highest quantitation accuracy lead to the unchallenged performance of ICP MS in efficiently detecting, identifying and reliably quantifying trace elements. The increasing availability of relevant reference compounds and high separation selectivity extend the molecular identification capability of ICP MS hyphenated to species-specific separation techniques. While molecular ion source MS is specialized in determining the structure of unknown molecules, ICP MS is an efficient and highly sensitive tool for target-element orientated discoveries of relevant and unknown compounds. This special-feature, tutorial article presents the principle and advantages of ICP MS, highlighting these using examples from recently published investigations. Copyright 2007 John Wiley & Sons, Ltd.
Rivera, Vanessa; Gaviria, Marcela; Muñoz-Cadavid, Cesar; Cano, Luz; Naranjo, Tonny
2015-01-01
The diagnosis of cryptococcosis is usually performed based on cultures of tissue or body fluids and isolation of the fungus, but this method may require several days. Direct microscopic examination, although rapid, is relatively insensitive. Biochemical and immunodiagnostic rapid tests are also used. However, all of these methods have limitations that may hinder final diagnosis. The increasing incidence of fungal infections has focused attention on tools for rapid and accurate diagnosis using molecular biological techniques. Currently, PCR-based methods, particularly nested, multiplex and real-time PCR, provide both high sensitivity and specificity. In the present study, we evaluated a nested PCR targeting the gene encoding the ITS-1 and ITS-2 regions of rDNA in samples from a cohort of patients diagnosed with cryptococcosis. The results showed that in our hands, this Cryptococcus nested PCR assay has 100% specificity and 100% sensitivity and was able to detect until 2 femtograms of Cryptococcus DNA. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.
Neuroimaging of Central Sensitivity Syndromes: Key Insights from the Scientific Literature
Walitt, Brian; Čeko, Marta; Gracely, John L.; Gracely, Richard H.
2016-01-01
Central sensitivity syndromes are characterized by distressing symptoms, such as pain and fatigue, in the absence of clinically obvious pathology. The scientific underpinnings of these disorders are not currently known. Modern neuroimaging techniques promise new insights into mechanisms mediating these postulated syndromes. We review the results of neuroimaging applied to five central sensitivity syndromes: fibromyalgia, chronic fatigue syndrome, irritable bowel syndrome, temporomandibular joint disorder, and vulvodynia syndrome. Neuroimaging studies of basal metabolism, anatomic constitution, molecular constituents, evoked neural activity, and treatment effect are compared across all of these syndromes. Evoked sensory paradigms reveal sensory augmentation to both painful and non-painful stimulation. This is a transformative observation for these syndromes, which were historically considered to be completely of hysterical or feigned in origin. However, whether sensory augmentation represents the cause of these syndromes, a predisposing factor, an endophenotype, or an epiphenomenon cannot be discerned from the current literature. Further, the result from cross-sectional neuroimaging studies of basal activity, anatomy, and molecular constituency are extremely heterogeneous within and between the syndromes. A defining neuroimaging “signature” cannot be discerned for any of the particular syndromes or for an over-arching central sensitization mechanism common to all of the syndromes. Several issues confound initial attempts to meaningfully measure treatment effects in these syndromes. At this time, the existence of “central sensitivity syndromes” is based more soundly on clinical and epidemiological evidence. A coherent picture of a “central sensitization” mechanism that bridges across all of these syndromes does not emerge from the existing scientific evidence. PMID:26717948
NASA Astrophysics Data System (ADS)
Furton, Kenneth G.; Almirall, Jose R.; Wang, Jing
1999-02-01
In this paper, we present data comparing a variety of different conditions for extracting ignitable liquid residues from simulated fire debris samples in order to optimize the conditions for using Solid Phase Microextraction. A simulated accelerant mixture containing 30 components, including those from light petroleum distillates, medium petroleum distillates and heavy petroleum distillates were used to study the important variables controlling Solid Phase Microextraction (SPME) recoveries. SPME is an inexpensive, rapid and sensitive method for the analysis of volatile residues from the headspace over solid debris samples in a container or directly from aqueous samples followed by GC. The relative effects of controllable variables, including fiber chemistry, adsorption and desorption temperature, extraction time, and desorption time, have been optimized. The addition of water and ethanol to simulated debris samples in a can was shown to increase the sensitivity when using headspace SPME extraction. The relative enhancement of sensitivity has been compared as a function of the hydrocarbon chain length, sample temperature, time, and added ethanol concentrations. The technique has also been optimized to the extraction of accelerants directly from water added to the fire debris samples. The optimum adsorption time for the low molecular weight components was found to be approximately 25 minutes. The high molecular weight components were found at a higher concentration the longer the fiber was exposed to the headspace (up to 1 hr). The higher molecular weight components were also found in higher concentrations in the headspace when water and/or ethanol was added to the debris.
Liu, Peng; Johansson, Viktor; Trilaksana, Herri; Rosdahl, Jan; Andersson, Gunther G; Kloo, Lars
2017-06-14
The organization of dye molecules in the dye layer adsorbed on the semiconductor substrate in dye-sensitized solar cells has been studied using a combination of theoretical methods and experimental techniques. The model system is based on the simple D-π-A dye L0, which has been chemically modified by substituting the acceptor group CN with Br (L0Br) to offer better X-ray contrast. Experimental EXAFS data based on the Br K-edge backscattering show no obvious difference between dye-sensitized titania powder and titania film samples, thus allowing model systems to be based on powder slurries. Ab initio molecular dynamic (aiMD) calculations have been performed to extract less biased information from the experimental EXASF data. Using the aiMD calculation as input, the EXAFS structural models can be generated a priori that match the experimental data. Our study shows that the L0Br dye adsorbs in the trans-L0Br configuration and that adsorption involves both a proximity to other L0Br dye molecules and the titanium atoms in the TiO 2 substrate. These results indicate direct coordination of the dye molecules to the TiO 2 surface in contrast to previous results on metal-organic dyes. The molecular coverage of L0Br on mesoporous TiO 2 was also estimated using NICIS spectroscopy. The NICISS results emphasized that the L0Br dye on nanoporous titania mainly forms monolayers with a small contribution of multilayer coverage.
Chalcogenide glass mid-infrared on-chip sensor for chemical sensing
NASA Astrophysics Data System (ADS)
Lin, Hongtao
Chemical sensing in the mid-infrared (mid-IR) has been considered to be significant for molecular detection for decades, but until recently has mostly relied on benchtop spectroscopic instruments like Fourier transform infrared spectrometers, etc. Recent strides in planar photonic integration envision compact, standalone "sensor-on-a-chip" devices for molecular analysis as a potentially disruptive technology as compared to their conventional bulky counterparts. However, the difficulty of achieving adequate sensitivity in integrated optical sensors is still a key barrier towards their practical application, limited by the weak interactions between photons and molecules over the short optical path length accessible on a chip. To solve the sensitivity challenge, a novel mid-IR photothermal spectroscopic sensing technique was proposed and theoretically examined. Through dramatically amplified photothermal effects in an optical nano-cavity doubly resonant at both mid-IR pump and near infrared probe wavelengths, a device design based on nested 1-D nanobeam photonic crystal cavities is numerically analyzed to demonstrate the technique's potential for single small gas molecule detection without the need for cryogenically cooled mid-IR photo-detectors. Furthermore, since silica becomes opaque at wavelengths beyond 3.5 microm, new material platforms and fabrication techniques are needed for mid-IR on-chip chemical sensors. Chalcogenide glasses (ChG), amorphous compounds containing S, Se and Te, are ideal material choices for mid-IR chemical sensors given their broad mid-IR transparency window, large photothermal figure-of-merit, amorphous structure and low processing temperature. A ChG lift-off process and a nano-fabrication technique using focused ion beam milling have been developed to fabricate mid-IR ChG resonators and photonic crystal waveguide cavities. ChG resonators on CaF2 substrate claimed a high quality factor around 4 x 105. Using these devices, we have also demonstrated mid-IR cavity enhanced absorption spectroscopy for the first time with mass loading limit of detection as low as 0.05 ng for ethanol.
Pascut, Flavius C.; Goh, Huey T.; Welch, Nathan; Buttery, Lee D.; Denning, Chris; Notingher, Ioan
2011-01-01
Raman microspectroscopy (RMS) was used to detect and image molecular markers specific to cardiomyocytes (CMs) derived from human embryonic stem cells (hESCs). This technique is noninvasive and thus can be used to discriminate individual live CMs within highly heterogeneous cell populations. Principal component analysis (PCA) of the Raman spectra was used to build a classification model for identification of individual CMs. Retrospective immunostaining imaging was used as the gold standard for phenotypic identification of each cell. We were able to discriminate CMs from other phenotypes with >97% specificity and >96% sensitivity, as calculated with the use of cross-validation algorithms (target 100% specificity). A comparison between Raman spectral images corresponding to selected Raman bands identified by the PCA model and immunostaining of the same cells allowed assignment of the Raman spectral markers. We conclude that glycogen is responsible for the discrimination of CMs, whereas myofibril proteins have a lesser contribution. This study demonstrates the potential of RMS for allowing the noninvasive phenotypic identification of hESC progeny. With further development, such label-free optical techniques may enable the separation of high-purity cell populations with mature phenotypes, and provide repeated measurements to monitor time-dependent molecular changes in live hESCs during differentiation in vitro. PMID:21190678
Rodent Brain Microinjection to Study Molecular Substrates of Motivated Behavior
Poland, Ryan S.; Bull, Cecilia; Syed, Wahab A.; Bowers, M. Scott
2015-01-01
Brain microinjection can aid elucidation of the molecular substrates of complex behaviors, such as motivation. For this purpose rodents can serve as appropriate models, partly because the response to behaviorally relevant stimuli and the circuitry parsing stimulus-action outcomes is astonishingly similar between humans and rodents. In studying molecular substrates of complex behaviors, the microinjection of reagents that modify, augment, or silence specific systems is an invaluable technique. However, it is crucial that the microinjection site is precisely targeted in order to aid interpretation of the results. We present a method for the manufacture of surgical implements and microinjection needles that enables accurate microinjection and unlimited customizability with minimal cost. Importantly, this technique can be successfully completed in awake rodents if conducted in conjunction with other JoVE articles that covered requisite surgical procedures. Additionally, there are many behavioral paradigms that are well suited for measuring motivation. The progressive ratio is a commonly used method that quantifies the efficacy of a reinforcer to maintain responding despite an (often exponentially) increasing work requirement. This assay is sensitive to reinforcer magnitude and pharmacological manipulations, which allows reinforcing efficacy and/ or motivation to be determined. We also present a straightforward approach to program operant software to accommodate a progressive ratio reinforcement schedule. PMID:26437131
NASA Astrophysics Data System (ADS)
Nurlela; Wibowo, R.; Gunlazuardi, J.
2017-04-01
Interaction between TiO2 and dyes sensitizer have been studied. The chlorophyll presents in the crude leave extract (CLE-dye) from cassava (Manihot utilissima) was immobilized on to the photo-anode, consists of TiO2 supported by fluor doped Tin oxide (SnO2-F) Glass. The TiO2 was prepared by Rapid Breakdown Anodization (RBA) method then immobilized on to glass coated by SnO2-F using doctor blade technique, to give CLE-dye/TiO2/SnO2-F/Glass photo-anode. The prepared photo-anode was characterized by UV-Vis-DRS, FTIR, XRD, SEM, electrochemical and spectro-electrochemical systems. In this study, the HOMO (highest occupied molecular orbital) and LUMO (lowest unoccupied molecular orbital) energy level of the CLE-dye were empirically determined by cyclic voltammetry method, while spectro-electro-chemistry method was used to determine the coefficient of degradation and formation of the dyes, and diffusion coefficient of the hole recombination as well. Good anchoring between TiO2 with dye extracts (CLE-dye) can be seen from value of dye LUMO energy level (-4.26 eV), which is approaching the conduction band of TiO2 (-4.3 eV). The coefficient of degradation and formation of the CLE-dye showed a quasi reversible and diffusion coefficient hole recombination values were small, indicated that it is quite suitable as a sensitizer in a dyes sensitized solar cell.
Sisco, Edward; Dake, Jeffrey
2016-04-14
Direct Analysis in Real Time Mass Spectrometry (DART-MS) has been used to detect the presence of non-narcotic adulterants in beverages. The non-narcotic adulterants that were examined in this work incorporated a number low molecular weight alcohols, acetone, ammonium hydroxide, and sodium hypochlorite. Analysis of the adulterants was completed by pipetting 1 µL deposits onto glass microcapillaries along with an appropriate dopant species followed by introduction into the DART gas stream. It was found that detection of these compounds in the complex matrices of common beverages (soda, energy drinks, etc.) was simplified through the use of a dopant species to allow for adduct formation with the desired compound(s) of interest. Other parameters that were investigated included DART gas stream temperature, in source collision induced dissociation, ion polarity, and DART needle voltage. Sensitivities of the technique were found to range from 0.001 % volume fraction to 0.1 % volume fraction, comparable to traditional analyses completed using headspace gas chromatography mass spectrometry (HS-GC/MS). Once a method was established using aqueous solutions, , fifteen beverages were spiked with each of the nine adulterants, to simulate real world detection, and in nearly all cases the adulterant could be detected either in pure form, or complexed with the added dopant species. This technique provides a rapid way to directly analyze beverages believed to be contaminated with non-narcotic adulterants at sensitivities similar to or exceeding those of traditional confirmatory analyses.
Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua
2017-01-01
Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.
Manipulating explosive sensitivity through structural modifications in a nitrate ester system
NASA Astrophysics Data System (ADS)
Manner, Virginia
2017-06-01
Understanding how condensed phase effects influence sensitivity is essential for developing next generation insensitive high explosives. However, the ability to predictably manipulate explosive sensitivity remains an elusive goal. Explosive sensitivity has been suggested to be governed by multiple factors, from intramolecular effects such as bond dissociation energy, oxygen balance, and the electrostatic potential of reactive functional groups, to larger scale effects, such as crystal structure and hot spot formation. We have developed derivatives of the explosive pentaerythritol tetranitrate (PETN) and examined them experimentally and theoretically, in order to better understand which properties influence sensitivity. With this molecular framework, we can evaluate how small changes to the structure of the molecule influence qualities such as oxygen balance, heat of formation, heat capacity, compressibility, crystal packing, and hydrogen bonding, through techniques such as differential scanning calorimetry, x-ray crystallography, and atomistic simulation. We have also used small-scale sensitivity testing as an initial tool to screen for large and consistent differences in handling sensitivity. We will discuss the many factors that contribute to sensitivity in this series of systematically-modified molecules as well as in existing well-studied explosive systems, such as triaminotrinitrobenzene (TATB) and nitroglycerin (NG). In collaboration with: Thomas Myers, Marc Cawkwell, Edward Kober, Bryce Tappan, Geoffrey Brown, Mary Sandstrom, LOS ALAMOS NATL LAB.
Development of MRM-based assays for the absolute quantitation of plasma proteins.
Kuzyk, Michael A; Parker, Carol E; Domanski, Dominik; Borchers, Christoph H
2013-01-01
Multiple reaction monitoring (MRM), sometimes called selected reaction monitoring (SRM), is a directed tandem mass spectrometric technique performed on to triple quadrupole mass spectrometers. MRM assays can be used to sensitively and specifically quantify proteins based on peptides that are specific to the target protein. Stable-isotope-labeled standard peptide analogues (SIS peptides) of target peptides are added to enzymatic digests of samples, and quantified along with the native peptides during MRM analysis. Monitoring of the intact peptide and a collision-induced fragment of this peptide (an ion pair) can be used to provide information on the absolute peptide concentration of the peptide in the sample and, by inference, the concentration of the intact protein. This technique provides high specificity by selecting for biophysical parameters that are unique to the target peptides: (1) the molecular weight of the peptide, (2) the generation of a specific fragment from the peptide, and (3) the HPLC retention time during LC/MRM-MS analysis. MRM is a highly sensitive technique that has been shown to be capable of detecting attomole levels of target peptides in complex samples such as tryptic digests of human plasma. This chapter provides a detailed description of how to develop and use an MRM protein assay. It includes sections on the critical "first step" of selecting the target peptides, as well as optimization of MRM acquisition parameters for maximum sensitivity of the ion pairs that will be used in the final method, and characterization of the final MRM assay.
Detection of Methylated Circulating DNA as Noninvasive Biomarkers for Breast Cancer Diagnosis
Cheuk, Isabella Wai Yin; Shin, Vivian Yvonne
2017-01-01
Internationally, breast cancer is the most common female cancer, and is induced by a combination of environmental, genetic, and epigenetic risk factors. Despite the advancement of imaging techniques, invasive sampling of breast epithelial cells is the only definitive diagnostic procedure for patients with breast cancer. To date, molecular biomarkers with high sensitivity and specificity for the screening and early detection of breast cancer are lacking. Recent evidence suggests that the detection of methylated circulating cell-free DNA in the peripheral blood of patients with cancer may be a promising quantitative and noninvasive method for cancer diagnosis. Methylation detection based on a multi-gene panel, rather than on the methylation status of a single gene, may be used to increase the sensitivity and specificity of breast cancer screening. In this review, the results of 14 relevant studies, investigating the efficacy of cell-free DNA methylation screening for breast cancer diagnosis, have been summarized. The genetic risk factors for breast cancer, the methods used for breast cancer detection, and the techniques and limitations related to the detection of cell-free DNA methylation status, have also been reviewed and discussed. From this review, we conclude that the analysis of peripheral blood or other samples to detect differentially methylated cell-free DNA is a promising technique for use in clinical settings, and may improve the sensitivity of screening for both, early detection and disease relapse, and thus improve the future prognosis of patients with breast cancer. PMID:28382090
Mitra, Amrit Krishna; Sau, Abhishek; Pal, Uttam; Saha, Chandan; Basu, Samita
2017-07-01
This paper vividly indicates that steady state as well as time-resolved fluorescence techniques can serve as highly sensitive monitors to explore the interactions of 5,7-dimethoxy-2,3,4,9-tetrahydro-1H-carbazol-1-one with model transport proteins, bovine serum albumin (BSA) and human serum albumin (HSA). Besides these, we have used fluorescence anisotropy study to assess the degree of restrictions imparted by the micro-environments of serum albumins. Again, to speculate the triplet excited state interaction between such fluorophore and albumin proteins (BSA& HSA), laser flash-photolysis experiments have been carried out. Molecular docking experiments have also been performed to support the conclusions obtained from steady state experiments.
Molecular Imaging and Precision Medicine in Lung Cancer.
Zukotynski, Katherine A; Gerbaudo, Victor H
2017-01-01
Precision medicine allows tailoring of preventive or therapeutic interventions to avoid the expense and toxicity of futile treatment given to those who will not respond. Lung cancer is a heterogeneous disease functionally and morphologically. PET is a sensitive molecular imaging technique with a major role in the precision medicine algorithm of patients with lung cancer. It contributes to the precision medicine of lung neoplasia by interrogating tumor heterogeneity throughout the body. It provides anatomofunctional insight during diagnosis, staging, and restaging of the disease. It is a biomarker of tumoral heterogeneity that helps direct selection of the most appropriate treatment, the prediction of early response to cytotoxic and cytostatic therapies, and is a prognostic biomarker in patients with lung cancer. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
From thermometric to spectrophotometric kinetic-catalytic methods of analysis. A review.
Cerdà, Víctor; González, Alba; Danchana, Kaewta
2017-05-15
Kinetic-catalytic analytical methods have proved to be very easy and highly sensitive strategies for chemical analysis, that rely on simple instrumentation [1,2]. Molecular absorption spectrophotometry is commonly used as the detection technique. However, other detection systems, like electrochemical or thermometric ones, offer some interesting possibilities since they are not affected by the color or turbidity of the samples. In this review some initial experience with thermometric kinetic-catalytic methods is described, up to our current experience exploiting spectrophotometric flow techniques to automate this kind of reactions, including the use of integrated chips. Procedures for determination of inorganic and organic species in organic and inorganic matrices are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Lei; Wu, Hongxu; Wang, Guiqi
2017-01-01
Endobronchial ultrasonography using a guide sheath (EBUS-GS) is a novel method used for collecting peripheral pulmonary lesion (PPL) samples. EBUS-GS is performed by introducing a guide sheath-covered miniprobe into the target bronchus and then withdrawing the miniprobe after lesion detection, leaving the guide sheath in situ as a working channel for obtaining lesion samples. EBUS-GS can improve PPL diagnosis rates and be used for obtaining specimens for molecular analysis. In this review, we discuss the clinical applications of EBUS-GS, the factors that affect its diagnostic sensitivity, and potential complications. We also compare EBUS-GS with other available diagnostic techniques and discuss the strengths and limitations of this method. PMID:29063872
NASA Astrophysics Data System (ADS)
Axner, Ove; Ehlers, Patrick; Hausmaninger, Thomas; Silander, Isak; Ma, Weiguang
2014-10-01
Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) is a powerful technique for detection of molecular compounds in gas phase that is based on a combination of two important concepts: frequency modulation spectroscopy (FMS) for reduction of noise, and cavity enhancement, for prolongation of the interaction length between the light and the sample. Due to its unique properties, it has demonstrated unparalleled detection sensitivity when it comes to detection of molecular constituents in the gas phase. However, despite these, it has so far not been used for detection of atoms, i.e. for elemental analysis. The present work presents an assessment of the expected performance of Doppler-broadened (Db) NICE-OHMS for analytical atomic spectrometry, then referred to as noise-immune cavity-enhanced analytical atomic spectrometry (NICE-AAS). After a description of the basic principles of Db-NICE-OHMS, the modulation and detection conditions for optimum performance are identified. Based on a previous demonstrated detection sensitivity of Db-NICE-OHMS of 5 × 10- 12 cm- 1 Hz- 1/2 (corresponding to a single-pass absorbance of 7 × 10- 11 over 10 s), the expected limits of detection (LODs) of Hg and Na by NICE-AAS are estimated. Hg is assumed to be detected in gas phase directly while Na is considered to be atomized in a graphite furnace (GF) prior to detection. It is shown that in the absence of spectral interferences, contaminated sample compartments, and optical saturation, it should be feasible to detect Hg down to 10 zg/cm3 (10 fg/m3 or 10- 5 ng/m3), which corresponds to 25 atoms/cm3, and Na down to 0.5 zg (zg = zeptogram = 10- 21 g), representing 50 zg/mL (parts-per-sextillion, pps, 1:1021) in liquid solution (assuming a sample of 10 μL) or solely 15 atoms injected into the GF, respectively. These LODs are several orders of magnitude lower (better) than any previous laser-based absorption technique previously demonstrated under atmospheric pressure conditions. It is prophesied that NICE-AAS could provide such high detection sensitivity that the instrumentation should not, by itself, be the limiting factor of an assessment of elemental abundance; the accuracy of an assessment would then instead be limited by concomitant species, e.g. originating from the handling procedures of the sample or the environment.
Molecular identification of Malassezia species isolated from dermatitis affections.
Affes, M; Ben Salah, S; Makni, F; Sellami, H; Ayadi, A
2009-05-01
The lipophilic yeast of the genus Malassezia are opportunistic microorganisms of the skin microflora but they can be agents of various dermatomycoses. The aim of this study was to perform molecular identification of the commonly isolated Malassezia species from various dermatomycoses in our region. Thirty strains of Malassezia were isolated from different dermatologic affections: pityriasis versicolor (17), dandruff (5), seborrheic dermatitis (4), onyxis (2), folliculitis (1) and blepharitis (1). These species were identified by their morphological features and biochemical characterisation. The molecular identification was achieved by amplification of the internal transcribed spacer region by simple PCR. PCR technique was used for molecular characterisation of four Malassezia species: Malassezia globosa (270 bp), Malassezia furfur (230 bp), Malassezia sympodialis (190 bp) and Malassezia restricta (320 bp). We have detected the association between M. furfur and M. sympodialis in 16% and confirmed presumptive identification in 70% of the cases. The phenotypic identification based on microscopic and physiological method is difficult and time consuming. The application of a simple PCR method provides a sensitive and rapid identification system for Malassezia species, which may be applied in epidemiological surveys and routine practice.
Virgilio, Edoardo; Giarnieri, Enrico; Giovagnoli, Maria Rosaria; Montagnini, Monica; Proietti, Antonella; D'Urso, Rosaria; Mercantini, Paolo; Valabrega, Stefano; Balducci, Genoveffa; Cavallini, Marco
2018-03-01
Detecting free tumor cells in the peritoneal lavage fluid of gastric cancer patients permits to assess a more accurate prognosis, predict peritoneal recurrence and select cases for a more aggressive treatment. Currently, cytology and molecular biology comprise the two most popular methods of detection that are under constant study by researchers. We burrowed into the available literature comparing cytological with molecular detection of free intraperitoneal gastric cancer cells. PubMed, Science Direct, Scopus and Google Scholar were the search engines investigated. As of 2017, 51 dedicated studies have been published. Messenger RNA of carcinoembryonic antigen was the genetic target most frequently described. The genetic technique is usually superior to cytology in sensitivity (38-100% vs. 12.3-67% respectively), whereas cytological examination tends to show a slight pre-eminence in specificity (approximately 100%). So far, given the imperfection of each method, employment of both cytology and molecular examination seem to be mandatory. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Single-Molecule Real-Time 3D Imaging of the Transcription Cycle by Modulation Interferometry.
Wang, Guanshi; Hauver, Jesse; Thomas, Zachary; Darst, Seth A; Pertsinidis, Alexandros
2016-12-15
Many essential cellular processes, such as gene control, employ elaborate mechanisms involving the coordination of large, multi-component molecular assemblies. Few structural biology tools presently have the combined spatial-temporal resolution and molecular specificity required to capture the movement, conformational changes, and subunit association-dissociation kinetics, three fundamental elements of how such intricate molecular machines work. Here, we report a 3D single-molecule super-resolution imaging study using modulation interferometry and phase-sensitive detection that achieves <2 nm axial localization precision, well below the few-nanometer-sized individual protein components. To illustrate the capability of this technique in probing the dynamics of complex macromolecular machines, we visualize the movement of individual multi-subunit E. coli RNA polymerases through the complete transcription cycle, dissect the kinetics of the initiation-elongation transition, and determine the fate of σ 70 initiation factors during promoter escape. Modulation interferometry sets the stage for single-molecule studies of several hitherto difficult-to-investigate multi-molecular transactions that underlie genome regulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Preservation of tumour oxygen after hyperbaric oxygenation monitored by magnetic resonance imaging
Kinoshita, Y; Kohshi, K; Kunugita, N; Tosaki, T; Yokota, A
1999-01-01
Hyperbaric oxygen (HBO) has been proposed to reduce tumour hypoxia by increasing the dissolved molecular oxygen in tissue. Using a non-invasive magnetic resonance imaging (MRI) technique, we monitored the changes in MRI signal intensity after HBO exposure because dissolved paramagnetic molecular oxygen itself shortens the T1 relation time. SCCVII tumour cells transplanted in mice were used. The molecular oxygen-enhanced MR images were acquired using an inversion recovery-preparation fast low angle shot (IR-FLASH) sequence sensitizing the paramagnetic effects of molecular oxygen using a 4.7 tesla MR system. MR signal of muscles decreased rapidly and returned to the control level within 40 min after decompression, whereas that of tumours decreased gradually and remained at a high level 60 min after HBO exposure. In contrast, the signal from the tumours in the normobaric oxygen group showed no significant change. Our data suggested that MR signal changes of tumours and muscles represent an alternation of extravascular oxygenation. The preserving tumour oxygen concentration after HBO exposure may be important regarding adjuvant therapy for cancer patients. © 2000 Cancer Research Campaign PMID:10638972
Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M
2016-05-01
To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Burns, Malcolm; Wiseman, Gordon; Knight, Angus; Bramley, Peter; Foster, Lucy; Rollinson, Sophie; Damant, Andrew; Primrose, Sandy
2016-01-07
Following a report on a significant amount of horse DNA being detected in a beef burger product on sale to the public at a UK supermarket in early 2013, the Elliott report was published in 2014 and contained a list of recommendations for helping ensure food integrity. One of the recommendations included improving laboratory testing capacity and capability to ensure a harmonised approach for testing for food authenticity. Molecular biologists have developed exquisitely sensitive methods based on the polymerase chain reaction (PCR) or mass spectrometry for detecting the presence of particular nucleic acid or peptide/protein sequences. These methods have been shown to be specific and sensitive in terms of lower limits of applicability, but they are largely qualitative in nature. Historically, the conversion of these qualitative techniques into reliable quantitative methods has been beset with problems even when used on relatively simple sample matrices. When the methods are applied to complex sample matrices, as found in many foods, the problems are magnified resulting in a high measurement uncertainty associated with the result which may mean that the assay is not fit for purpose. However, recent advances in the technology and the understanding of molecular biology approaches have further given rise to the re-assessment of these methods for their quantitative potential. This review focuses on important issues for consideration when validating a molecular biology assay and the various factors that can impact on the measurement uncertainty of a result associated with molecular biology approaches used in detection of food fraud, with a particular focus on quantitative PCR-based and proteomics assays.
Investigating buried polymer interfaces using sum frequency generation vibrational spectroscopy
Chen, Zhan
2010-01-01
This paper reviews recent progress in the studies of buried polymer interfaces using sum frequency generation (SFG) vibrational spectroscopy. Both buried solid/liquid and solid/solid interfaces involving polymeric materials are discussed. SFG studies of polymer/water interfaces show that different polymers exhibit varied surface restructuring behavior in water, indicating the importance of probing polymer/water interfaces in situ. SFG has also been applied to the investigation of interfaces between polymers and other liquids. It has been found that molecular interactions at such polymer/liquid interfaces dictate interfacial polymer structures. The molecular structures of silane molecules, which are widely used as adhesion promoters, have been investigated using SFG at buried polymer/silane and polymer/polymer interfaces, providing molecular-level understanding of polymer adhesion promotion. The molecular structures of polymer/solid interfaces have been examined using SFG with several different experimental geometries. These results have provided molecular-level information about polymer friction, adhesion, interfacial chemical reactions, interfacial electronic properties, and the structure of layer-by-layer deposited polymers. Such research has demonstrated that SFG is a powerful tool to probe buried interfaces involving polymeric materials, which are difficult to study by conventional surface sensitive analytical techniques. PMID:21113334
Molecular Characterization of Growth Hormone-producing Tumors in the GC Rat Model of Acromegaly.
Martín-Rodríguez, Juan F; Muñoz-Bravo, Jose L; Ibañez-Costa, Alejandro; Fernandez-Maza, Laura; Balcerzyk, Marcin; Leal-Campanario, Rocío; Luque, Raúl M; Castaño, Justo P; Venegas-Moreno, Eva; Soto-Moreno, Alfonso; Leal-Cerro, Alfonso; Cano, David A
2015-11-09
Acromegaly is a disorder resulting from excessive production of growth hormone (GH) and consequent increase of insulin-like growth factor 1 (IGF-I), most frequently caused by pituitary adenomas. Elevated GH and IGF-I levels results in wide range of somatic, cardiovascular, endocrine, metabolic, and gastrointestinal morbidities. Subcutaneous implantation of the GH-secreting GC cell line in rats leads to the formation of tumors. GC tumor-bearing rats develop characteristics that resemble human acromegaly including gigantism and visceromegaly. However, GC tumors remain poorly characterized at a molecular level. In the present work, we report a detailed histological and molecular characterization of GC tumors using immunohistochemistry, molecular biology and imaging techniques. GC tumors display histopathological and molecular features of human GH-producing tumors, including hormone production, cell architecture, senescence activation and alterations in cell cycle gene expression. Furthermore, GC tumors cells displayed sensitivity to somatostatin analogues, drugs that are currently used in the treatment of human GH-producing adenomas, thus supporting the GC tumor model as a translational tool to evaluate therapeutic agents. The information obtained would help to maximize the usefulness of the GC rat model for research and preclinical studies in GH-secreting tumors.
Molecular Characterization of Growth Hormone-producing Tumors in the GC Rat Model of Acromegaly
Martín-Rodríguez, Juan F.; Muñoz-Bravo, Jose L.; Ibañez-Costa, Alejandro; Fernandez-Maza, Laura; Balcerzyk, Marcin; Leal-Campanario, Rocío; Luque, Raúl M.; Castaño, Justo P.; Venegas-Moreno, Eva; Soto-Moreno, Alfonso; Leal-Cerro, Alfonso; Cano, David A.
2015-01-01
Acromegaly is a disorder resulting from excessive production of growth hormone (GH) and consequent increase of insulin-like growth factor 1 (IGF-I), most frequently caused by pituitary adenomas. Elevated GH and IGF-I levels results in wide range of somatic, cardiovascular, endocrine, metabolic, and gastrointestinal morbidities. Subcutaneous implantation of the GH-secreting GC cell line in rats leads to the formation of tumors. GC tumor-bearing rats develop characteristics that resemble human acromegaly including gigantism and visceromegaly. However, GC tumors remain poorly characterized at a molecular level. In the present work, we report a detailed histological and molecular characterization of GC tumors using immunohistochemistry, molecular biology and imaging techniques. GC tumors display histopathological and molecular features of human GH-producing tumors, including hormone production, cell architecture, senescence activation and alterations in cell cycle gene expression. Furthermore, GC tumors cells displayed sensitivity to somatostatin analogues, drugs that are currently used in the treatment of human GH-producing adenomas, thus supporting the GC tumor model as a translational tool to evaluate therapeutic agents. The information obtained would help to maximize the usefulness of the GC rat model for research and preclinical studies in GH-secreting tumors. PMID:26549306
Fluorescent probes for lipid rafts: from model membranes to living cells.
Klymchenko, Andrey S; Kreder, Rémy
2014-01-16
Membrane microdomains (rafts) remain one of the controversial issues in biophysics. Fluorescent molecular probes, which make these lipid nanostructures visible through optical techniques, are one of the tools currently used to study lipid rafts. The most common are lipophilic fluorescent probes that partition specifically into liquid ordered or liquid disordered phase. Their partition depends on the lipid composition of a given phase, which complicates their use in cellular membranes. A second class of probes is based on environment-sensitive dyes, which partition into both phases, but stain them by different fluorescence color, intensity, or lifetime. These probes can directly address the properties of each separate phase, but their cellular applications are still limited. The present review focuses on summarizing the current state in the field of developing and applying fluorescent molecular probes to study lipid rafts. We highlight an urgent need to develop new probes, specifically adapted for cell plasma membranes and compatible with modern fluorescence microscopy techniques to push the understanding of membrane microdomains forward. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Shirinzadeh, B.; Herring, G. C.; Barros, Toya
1999-01-01
The feasibility of using the Rayleigh scattering technique for molecular density imaging of the free-stream flow field in the Langley 0.3-Meter Transonic Cryogenic Tunnel has been experimentally demonstrated. The Rayleigh scattering was viewed with a near-backward geometry with a frequency-doubled output from a diode-pumped CW Nd:YAG laser and an intensified charge-coupled device camera. Measurements performed in the range of free-stream densities from 3 x 10(exp 25) to 24 x 10(exp 25) molecules/cu m indicate that the observed relative Rayleigh signal levels are approximately linear with flow field density. The absolute signal levels agree (within approx. 30 percent) with the expected signal levels computed based on the well-known quantities of flow field density, Rayleigh scattering cross section for N2, solid angle of collection, transmission of the optics, and the independently calibrated camera sensitivity. These results show that the flow field in this facility is primarily molecular (i.e., not contaminated by clusters) and that Rayleigh scattering is a viable technique for quantitative nonintrusive diagnostics in this facility.
Isoquinoline alkaloids and their binding with DNA: calorimetry and thermal analysis applications.
Bhadra, Kakali; Kumar, Gopinatha Suresh
2010-11-01
Alkaloids are a group of natural products with unmatched chemical diversity and biological relevance forming potential quality pools in drug screening. The molecular aspects of their interaction with many cellular macromolecules like DNA, RNA and proteins are being currently investigated in order to evolve the structure activity relationship. Isoquinolines constitute an important group of alkaloids. They have extensive utility in cancer therapy and a large volume of data is now emerging in the literature on their mode, mechanism and specificity of binding to DNA. Thermodynamic characterization of the binding of these alkaloids to DNA may offer key insights into the molecular aspects that drive complex formation and these data can provide valuable information about the balance of driving forces. Various thermal techniques have been conveniently used for this purpose and modern calorimetric instrumentation provides direct and quick estimation of thermodynamic parameters. Thermal melting studies and calorimetric techniques like isothermal titration calorimetry and differential scanning calorimetry have further advanced the field by providing authentic, reliable and sensitive data on various aspects of temperature dependent structural analysis of the interaction. In this review we present the application of various thermal techniques, viz. isothermal titration calorimetry, differential scanning calorimetry and optical melting studies in the characterization of drug-DNA interactions with particular emphasis on isoquinoline alkaloid-DNA interaction.
NASA Astrophysics Data System (ADS)
Peterson, Katie L.; Srivastava, Kriti; Pierre, Valérie C.
2018-05-01
Fluorine magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) of chemical and physiological processes is becoming more widespread. The strength of this technique comes from the negligible background signal in in vivo 19F MRI and the large chemical shift window of 19F that enables it to image concomitantly more than one marker. These same advantages have also been successfully exploited in the design of responsive 19F probes. Part of the recent growth of this technique can be attributed to novel designs of 19F probes with improved imaging parameters due to the incorporation of paramagnetic metal ions. In this review, we provide a description of the theories and strategies that have been employed successfully to improve the sensitivity of 19F probes with paramagnetic metal ions. The Bloch-Wangsness-Redfield theory accurately predicts how molecular parameters such as distance, geometry, rotational correlation times, as well as the nature, oxidation state, and spin state of the metal ion affect the sensitivity of the fluorine-based probes. The principles governing the design of responsive 19F probes are subsequently described in a “how to” guide format. Examples of such probes and their advantages and disadvantages are highlighted through a synopsis of the literature.
Prasad, Bhim Bali; Srivastava, Amrita; Tiwari, Mahavir Prasad
2013-03-29
The present work is related to combination of molecularly imprinted solid-phase microextraction and complementary molecularly imprinted polymer-sensor. The molecularly imprinted polymer grafted on titanium dioxide modified silica fiber was used for microextraction, while the same polymer immobilized on multiwalled carbon nanotubes/titanium dioxide modified pencil graphite electrode served as a detection tool. In both cases, the surface initiated polymerization was found to be advantageous to obtain a nanometer thin imprinted film. The modified silica fiber exhibited high adsorption capacity and enantioselective diffusion of aspartic acid isomers into respective molecular cavities. This combination enabled double preconcentrations of d- and l-aspartic acid that helped sensing both isomers in real samples, without any cross-selectivity and matrix complications. Taking into account 6×10(4)-fold dilution of serum and 2×10(3)-fold dilution of cerebrospinal fluid required by the proposed method, the limit of detection for l-aspartic acid is 0.031ngmL(-1). Also, taking into account 50-fold dilution required by the proposed method, the limit of detection for d-aspartic acid is 0.031ngmL(-1) in cerebrospinal fluid. Copyright © 2013 Elsevier B.V. All rights reserved.
Ground-based mm-wave emission spectroscopy for the detection and monitoring of stratospheric ozone
NASA Technical Reports Server (NTRS)
Parrish, A.; Dezafra, R.; Solomon, P.
1981-01-01
The molecular rotational spectrum of ozone is quite rich in the mm-wave region from 50 to 300 GHz. An apparatus, which was developed primarily for detection and measurement of stratospheric ClO and other trace molecules, is found to be well suited also for the observation of ozone lines. The collecting antenna of the apparatus is a simple mm-waveguide feedhorn. The detector is a superheterodyne mixer using a special high frequency Schottky diode and a klystron local oscillator. The spectrometer is a 256 channel filter bank with 1 MHz resolution per channel. The apparatus is believed to be the first ground-based mm-wave instrument having the capability of obtaining data of sufficient quality to make use of the inversion technique. The ground based radio technique is most sensitive to changes in vertical distribution in the region above 25 km, a region which is difficult to sample by other techniques.
Bartholomew, J.L.; Arkoosh , M.R.; Rohovec, J.S.
1991-01-01
The specificity of the antibody response of salmonids to Renibacterium salmoninarum antigens was demonstrated by western blotting techniques that utilized a monoclonal antibody against salmonid immunoglobulin. In this study, the specificity of the response in immunized chinook salmon Oncorhynchus tshawytschawas compared with the response in naturally infected chinook salmon and coho salmon O. kisutch, and immunized rabbits. The antibody response in immunized salmon and rabbits and the naturally infected fish was primarily against the 57–58kilodalton protein complex. In addition to recognizing these proteins in the extracellular fraction and whole-cell preparations, antibody from the immunized salmon and rabbits detected four proteins with lower molecular masses. Western blotting techniques allow identification of the specific antigens recognized and are a useful tool for comparing the immunogenicity of different R. salmoninarumpreparations. Immunofluorescent techniques with whole bacteria were less sensitive than western blotting in detecting salmonid anti-R. salmoninarumantibody.
Laudat, P; Demondion, E; Jouannet, C; Charron, J; Chillou, C; Salaun, V; Mankikian, B
2012-06-01
Patients admitted in cardiac surgery and cardiac ICU at the Clinic Saint-Gatien (Tours) are screened for MRSA at the entrance by nasal swab and culture on blood agar and selective chromogenic medium made by addition of cefoxitin: BBL CHROMagar MRSA-II BD (result obtained at Day +1). We wanted to assess the molecular biology techniques available to obtain a result at day 0 for the majority of patients and to define an economic and practical strategy for the laboratory. We studied four molecular biology techniques: Cepheid GeneXpert (Cepheid) GeneOhm (BD), LightCycler (Roche) and Hyplex (I2A). Upon reception, nasal swabs were treated by culture, considered as reference, and one of the techniques of molecular biology, according to the manufacturer's notice. We conducted four studies between April 2008 and February 2009 to obtain a significant sample for each of them. By screening we mean a method that allows us to exclude MRSA carriage for patients waiting for surgery, and not to change patient management: for example, lack of isolation measures specific to entrance, no modification of antibiotic prophylaxis during surgery and no isolation measures in the immediate postoperative period. The criteria we considered for this evaluation were: (1) technician time: time to perform one or a series of sample(s) n=10 or more (about 2h for all techniques except GeneXpert 75min), level of skilled competences (no specific training for GeneXpert); (2) results: turnaround time (all molecular biology techniques), ease of reading and results interpretations (no specialized training required for GeneXpert), failure or not (12% of failure of internal controls for GeneOhm); (3) economic: cost for one or a series of sample(s) (n=10 or more), if we considered X as the reference culture cost (10 X Hyplex and LightCycler, 20 X and 40 X for GeneXpert GeneOhm); (4) NPV: 100% for GeneXpert and LightCycler. At same sensitivity, no technique, including culture, can solve alone our problem, which is: (1) get results at day 0 for batch of samples (n<10): all molecular biology techniques; (2) beyond 10 samples: LightCycler (Roche) automated or Hyplex (I2A) manual; (3) when the result at day 1 is sufficient, the use of chromogenic agar with a reading of less than 18h as BBL CHROMagar MRSA II (BD) remains the most economical; (4) to be sure that a patient admitted at Day 0, even at night's emergency, is not carrier of MRSA: only Cepheid GeneXpert technology (IL). Furthermore, Cepheid GeneXpert (IL) allows performing several tests in parallel. The rapidity of this system can help control the transmission and make better use of antibiotics. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salvador Palau, A.; Eder, S. D., E-mail: sabrina.eder@uib.no; Kaltenbacher, T.
Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beammore » using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.« less
Mayahi, Mansour; Gharibi, Darioush; Ghadimipour, Rahim; Talazadeh, Forough
2016-01-01
Ornithobacterium rhinotracheale (ORT) is a bacterium associated with respiratory disease, growth retardation, decreased egg production and mortality in chickens and turkeys. The objective of this study was isolation, identification and evaluation of antimicrobial susceptibility of ORT bacterium in slaughtered broilers chicken flocks based on cultural and molecular tests in Khuzestan province, south-west of Iran. A total of 210 tracheal swab samples were collected from 21 broiler flocks slaughtered in abattoirs of the province. The results of cultural and biochemical tests showed that 23 (10.95%) isolates from tracheal swabs of 4 flocks (19.04%) were identified as ORT, but according to molecular characterization, 18 (8.57%) ORT isolates were positive in PCR assay and produced the predicted 784 bp amplification product. Finally, using the disk diffusion method, the drug resistance patterns of ORT isolates were determined against a panel of commonly used antimicrobial agents. Antimicrobial susceptibility test revealed that all isolates (100%) were sensitive to tetracycline, florfenicol and cephalexin. The highest antimicrobial resistance (89.00%) was seen for fosfomycin, sultrim and gentamicin. The results of present research showed that there was significant difference between the isolation rates of ORT from various areas of the province. As well, our findings indicated that the simultaneous use of both cultural and molecular techniques results in more comprehensive outcomes in the isolation and identification of the organismfrom understudy hosts. PMID:28144427
Leishmania infections: Molecular targets and diagnosis.
Akhoundi, Mohammad; Downing, Tim; Votýpka, Jan; Kuhls, Katrin; Lukeš, Julius; Cannet, Arnaud; Ravel, Christophe; Marty, Pierre; Delaunay, Pascal; Kasbari, Mohamed; Granouillac, Bruno; Gradoni, Luigi; Sereno, Denis
2017-10-01
Progress in the diagnosis of leishmaniases depends on the development of effective methods and the discovery of suitable biomarkers. We propose firstly an update classification of Leishmania species and their synonymies. We demonstrate a global map highlighting the geography of known endemic Leishmania species pathogenic to humans. We summarize a complete list of techniques currently in use and discuss their advantages and limitations. The available data highlights the benefits of molecular markers in terms of their sensitivity and specificity to quantify variation from the subgeneric level to species complexes, (sub) species within complexes, and individual populations and infection foci. Each DNA-based detection method is supplied with a comprehensive description of markers and primers and proposal for a classification based on the role of each target and primer in the detection, identification and quantification of leishmaniasis infection. We outline a genome-wide map of genes informative for diagnosis that have been used for Leishmania genotyping. Furthermore, we propose a classification method based on the suitability of well-studied molecular markers for typing the 21 known Leishmania species pathogenic to humans. This can be applied to newly discovered species and to hybrid strains originating from inter-species crosses. Developing more effective and sensitive diagnostic methods and biomarkers is vital for enhancing Leishmania infection control programs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Rapid screening for human-pathogenic Mucorales using rolling circle amplification.
Dolatabadi, S; Najafzadeh, M J; de Hoog, G S
2014-12-01
Mucormycosis has emerged as a relatively common severe mycosis in patients with haematological and allogeneic stem cell transplantation. Source of transmission is from unidentified sources in the environment. Early diagnosis of infection and its source of contamination are paramount for rapid and appropriate therapy. In this study, rolling circle amplification (RCA) is introduced as a sensitive, specific and reproducible isothermal DNA amplification technique for rapid molecular identification of six of the most virulent species (Rhizopus microsporus, R. arrhizus var. arrhizus, R. arrhizus var. delemar, Mucor irregularis, Mucor circinelloides, Lichtheimia ramosa, Lichtheimia corymbifera). DNAs of target species were successfully amplified, with no cross reactivity between species. RCA can be considered as a rapid detection method with high specificity and sensitivity, suitable for large screening. © 2014 Blackwell Verlag GmbH.
Novel Electrochemical Raman Spectroscopy Enabled by Water Immersion Objective.
Zeng, Zhi-Cong; Hu, Shu; Huang, Sheng-Chao; Zhang, Yue-Jiao; Zhao, Wei-Xing; Li, Jian-Feng; Jiang, Chaoyang; Ren, Bin
2016-10-04
Electrochemical Raman spectroscopy is a powerful molecular level diagnostic technique for in situ investigation of adsorption and reactions on various material surfaces. However, there is still a big room to improve the optical path to meet the increasing request of higher detection sensitivity and spatial resolution. Herein, we proposed a novel electrochemical Raman setup based on a water immersion objective. It dramatically reduces mismatch of the refractive index in the light path. Consequently, significant improvement in detection sensitivity and spatial resolution has been achieved from both Zemax simulation and the experimental results. Furthermore, the thickness of electrolyte layer could be expanded to 2 mm without any influence on the signal collection. Such a thick electrolyte layer allows a much normal electrochemical response during the spectroelectrochemical investigations of the methanol oxidation.
Single-molecule protein sequencing through fingerprinting: computational assessment
NASA Astrophysics Data System (ADS)
Yao, Yao; Docter, Margreet; van Ginkel, Jetty; de Ridder, Dick; Joo, Chirlmin
2015-10-01
Proteins are vital in all biological systems as they constitute the main structural and functional components of cells. Recent advances in mass spectrometry have brought the promise of complete proteomics by helping draft the human proteome. Yet, this commonly used protein sequencing technique has fundamental limitations in sensitivity. Here we propose a method for single-molecule (SM) protein sequencing. A major challenge lies in the fact that proteins are composed of 20 different amino acids, which demands 20 molecular reporters. We computationally demonstrate that it suffices to measure only two types of amino acids to identify proteins and suggest an experimental scheme using SM fluorescence. When achieved, this highly sensitive approach will result in a paradigm shift in proteomics, with major impact in the biological and medical sciences.
Determination of Diffusion Parameters of CO2 Through Microporous PTFE Using a Potentiometric Method
NASA Astrophysics Data System (ADS)
Tarsiche, I.; Ciurchea, D.
Dk values at the diffusion of CO2 through microporous PTFE of 1 to 7 × 10- 7 cm2 s- 1 in the concentration range from 4 × 10- 4 to 0.22 g/l CO2 are determined using a simple, fast and reliable potentiometric method. The method is based on the least-squares fitting of the potential versus time response of a self made CO2 sensitive Severinghaus type sensor with PTFE as a gas-permeable membrane. The obtained results are in good agreement with other reported literature data, both experimental or calculated ones using molecular dynamics simulations. The proposed technique is very sensitive especially at low concentrations of gas and may be used for the study of other polymeric membranes too.
Kasama, Toshihiro; Kaji, Noritada; Tokeshi, Manabu; Baba, Yoshinobu
2017-01-01
Due to the inherent characteristics including confinement of molecular diffusion and high surface-to-volume ratio, microfluidic device-based immunoassay has great advantages in cost, speed, sensitivity, and so on, compared with conventional techniques such as microtiter plate-based ELISA, latex agglutination method, and lateral flow immunochromatography. In this paper, we explain the detection of C-reactive protein as a model antigen by using our microfluidic immunoassay device, so-called immuno-pillar device. We describe in detail how we fabricated and used the immuno-pillar devices.
Magic Angle Spinning NMR Metabolomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhi Hu, Jian
Nuclear Magnetic Resonance (NMR) spectroscopy is a non-destructive, quantitative, reproducible, untargeted and unbiased method that requires no or minimal sample preparation, and is one of the leading analytical tools for metabonomics research [1-3]. The easy quantification and the no need of prior knowledge about compounds present in a sample associated with NMR are advantageous over other techniques [1,4]. 1H NMR is especially attractive because protons are present in virtually all metabolites and its NMR sensitivity is high, enabling the simultaneous identification and monitoring of a wide range of low molecular weight metabolites.
Pitfalls in PCR troubleshooting: Expect the unexpected?
Schrick, Livia; Nitsche, Andreas
2015-01-01
PCR is a well-understood and established laboratory technique often used in molecular diagnostics. Huge experience has been accumulated over the last years regarding the design of PCR assays and their set-up, including in-depth troubleshooting to obtain the optimal PCR assay for each purpose. Here we report a PCR troubleshooting that came up with a surprising result never observed before. With this report we hope to sensitize the reader to this peculiar problem and to save troubleshooting efforts in similar situations, especially in time-critical and ambitious diagnostic settings. PMID:27077041
Superhydrophobic Ag nanostructures on polyaniline membranes with strong SERS enhancement.
Liu, Weiyu; Miao, Peng; Xiong, Lu; Du, Yunchen; Han, Xijiang; Xu, Ping
2014-11-07
We demonstrate here a facile fabrication of n-dodecyl mercaptan-modified superhydrophobic Ag nanostructures on polyaniline membranes for molecular detection based on SERS technique, which combines the superhydrophobic condensation effect and the high enhancement factor. It is calculated that the as-fabricated superhydrophobic substrate can exhibit a 21-fold stronger molecular condensation, and thus further amplifies the SERS signal to achieve more sensitive detection. The detection limit of the target molecule, methylene blue (MB), on this superhydrophobic substrate can be 1 order of magnitude higher than that on the hydrophilic substrate. With high reproducibility, the feasibility of using this SERS-active superhydrophobic substrate for quantitative molecular detection is explored. A partial least squares (PLS) model was established for the quantification of MB by SERS, with correlation coefficient R(2) = 95.1% and root-mean-squared error of prediction (RMSEP) = 0.226. We believe this superhydrophobic SERS substrate can be widely used in trace analysis due to its facile fabrication, high signal reproducibility and promising SERS performance.
Jensen, Malene Ringkjøbing; Bernadó, Pau; Houben, Klaartje; Blanchard, Laurence; Marion, Dominque; Ruigrok, Rob W H; Blackledge, Martin
2010-08-01
Intrinsically disordered regions of significant length are present throughout eukaryotic genomes, and are particularly prevalent in viral proteins. Due to their inherent flexibility, these proteins inhabit a conformational landscape that is too complex to be described by classical structural biology. The elucidation of the role that conformational flexibility plays in molecular function will redefine our understanding of the molecular basis of biological function, and the development of appropriate technology to achieve this aim remains one of the major challenges for the future of structural biology. NMR is the technique of choice for studying intrinsically disordered proteins, providing information about structure, flexibility and interactions at atomic resolution even in completely disordered proteins. In particular residual dipolar couplings (RDCs) are sensitive and powerful tools for determining local and long-range structural behaviour in flexible proteins. Here we describe recent applications of the use of RDCs to quantitatively describe the level of local structure in intrinsically disordered proteins involved in replication and transcription in Sendai virus.
Hofman, Anton H; Reza, Mehedi; Ruokolainen, Janne; Ten Brinke, Gerrit; Loos, Katja
2017-09-01
Involving supramolecular chemistry in self-assembling block copolymer systems enables design of complex macromolecular architectures that, in turn, could lead to complex phase behavior. It is an elegant route, as complicated and sensitive synthesis techniques can be avoided. Highly grafted double-comb diblock copolymers based on symmetric double hydrogen bond accepting poly(4-vinylpyridine)-block-poly(N-acryloylpiperidine) diblock copolymers and donating 3-nonadecylphenol amphiphiles are realized and studied systematically by changing the molecular weight of the copolymer. Double perpendicular lamellae-in-lamellae are formed in all complexes, independent of the copolymer molecular weight. Temperature-resolved measurements demonstrate that the supramolecular nature and ability to crystallize are responsible for the formation of such multiblock-like structures. Because of these driving forces and severe plasticization of the complexes in the liquid crystalline state, this supramolecular approach can be useful for steering self-assembly of both low- and high-molecular-weight block copolymer systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Saylor, Karen L.; Anver, Miriam R.; Salomon, David S.; Golubeva, Yelena G.
2016-01-01
Laser capture microdissection (LCM) of tissue is an established tool in medical research for collection of distinguished cell populations under direct microscopic visualization for molecular analysis. LCM samples have been successfully analyzed in a number of genomic and proteomic downstream molecular applications. However, LCM sample collection and preparation procedure has to be adapted to each downstream analysis platform. In this present manuscript we describe in detail the adaptation of LCM methodology for the collection and preparation of fresh frozen samples for NanoString analysis based on a study of a model of mouse mammary gland carcinoma and its lung metastasis. Our adaptation of LCM sample preparation and workflow to the requirements of the NanoString platform allowed acquiring samples with high RNA quality. The NanoString analysis of such samples provided sensitive detection of genes of interest and their associated molecular pathways. NanoString is a reliable gene expression analysis platform that can be effectively coupled with LCM. PMID:27077656
In Silico PCR Tools for a Fast Primer, Probe, and Advanced Searching.
Kalendar, Ruslan; Muterko, Alexandr; Shamekova, Malika; Zhambakin, Kabyl
2017-01-01
The polymerase chain reaction (PCR) is fundamental to molecular biology and is the most important practical molecular technique for the research laboratory. The principle of this technique has been further used and applied in plenty of other simple or complex nucleic acid amplification technologies (NAAT). In parallel to laboratory "wet bench" experiments for nucleic acid amplification technologies, in silico or virtual (bioinformatics) approaches have been developed, among which in silico PCR analysis. In silico NAAT analysis is a useful and efficient complementary method to ensure the specificity of primers or probes for an extensive range of PCR applications from homology gene discovery, molecular diagnosis, DNA fingerprinting, and repeat searching. Predicting sensitivity and specificity of primers and probes requires a search to determine whether they match a database with an optimal number of mismatches, similarity, and stability. In the development of in silico bioinformatics tools for nucleic acid amplification technologies, the prospects for the development of new NAAT or similar approaches should be taken into account, including forward-looking and comprehensive analysis that is not limited to only one PCR technique variant. The software FastPCR and the online Java web tool are integrated tools for in silico PCR of linear and circular DNA, multiple primer or probe searches in large or small databases and for advanced search. These tools are suitable for processing of batch files that are essential for automation when working with large amounts of data. The FastPCR software is available for download at http://primerdigital.com/fastpcr.html and the online Java version at http://primerdigital.com/tools/pcr.html .
Te, Shu Harn; Chen, Enid Yingru; Gin, Karina Yew-Hoong
2015-08-01
The increasing occurrence of harmful cyanobacterial blooms, often linked to deteriorated water quality and adverse public health effects, has become a worldwide concern in recent decades. The use of molecular techniques such as real-time quantitative PCR (qPCR) has become increasingly popular in the detection and monitoring of harmful cyanobacterial species. Multiplex qPCR assays that quantify several toxigenic cyanobacterial species have been established previously; however, there is no molecular assay that detects several bloom-forming species simultaneously. Microcystis and Cylindrospermopsis are the two most commonly found genera and are known to be able to produce microcystin and cylindrospermopsin hepatotoxins. In this study, we designed primers and probes which enable quantification of these genera based on the RNA polymerase C1 gene for Cylindrospermopsis species and the c-phycocyanin beta subunit-like gene for Microcystis species. Duplex assays were developed for two molecular techniques-qPCR and droplet digital PCR (ddPCR). After optimization, both qPCR and ddPCR assays have high linearity and quantitative correlations for standards. Comparisons of the two techniques showed that qPCR has higher sensitivity, a wider linear dynamic range, and shorter analysis time and that it was more cost-effective, making it a suitable method for initial screening. However, the ddPCR approach has lower variability and was able to handle the PCR inhibition and competitive effects found in duplex assays, thus providing more precise and accurate analysis for bloom samples. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Mixed infections in tuberculosis: The missing part in a puzzle.
Tarashi, Samira; Fateh, Abolfazl; Mirsaeidi, Mehdi; Siadat, Seyed Davar; Vaziri, Farzam
2017-12-01
The mixed strains infection phenomenon is a major problem posing serious challenges in control of tuberculosis (TB). In patients with mixed infection, several different strains of Mycobacterium tuberculosis can be isolated simultaneously. Although different genotyping methods and various molecular approaches can be employed for detection of mixed infection in clinical samples, the MIRU-VNTR technique is more sensitive with higher discriminative power than many widely used techniques. Furthermore, the recent introduction of whole genome sequencing (WGS) promises to reveal more details about mixed infection with high resolution. WGS has been used for detection of mixed infection with high sensitivity and discriminatory, but the technology is currently limited to developed countries. Mixed infection may involve strains with different susceptibility patterns, which may alter the treatment outcome. In this report, we review the current concepts of mixed strains infection and also infection involving strains with a different susceptibility pattern in TB. We evaluate the importance of identifying mixed infection for diagnosis as well as treatment and highlight the accuracy and clinical utility of direct genotyping of clinical specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of phase detection schemes based on surface plasmon resonance using interferometry.
Kashif, Muhammad; Bakar, Ahmad Ashrif A; Arsad, Norhana; Shaari, Sahbudin
2014-08-28
Surface plasmon resonance (SPR) is a novel optical sensing technique with a unique ability to monitor molecular binding in real-time for biological and chemical sensor applications. Interferometry is an excellent tool for accurate measurement of SPR changes, the measurement and comparison is made for the sensitivity, dynamic range and resolution of the different analytes using interferometry techniques. SPR interferometry can also employ phase detection in addition to the amplitude of the reflected light wave, and the phase changes more rapidly compared with other approaches, i.e., intensity, angle and wavelength. Therefore, the SPR phase interferometer offers the advantages of spatial phase resolution and high sensitivity. This work discusses the advancements in interferometric SPR methods to measure the phase shifts due to refractive index changes. The main application areas of SPR sensors are demonstrated, i.e., the Fabry-Perot interferometer, Michelson interferometer and Mach-Zehnder interferometer, with different configurations. The three interferometers are discussed in detail, and solutions are suggested to enhance the performance parameters that will aid in future biological and chemical sensors.
Development of Phase Detection Schemes Based on Surface Plasmon Resonance Using Interferometry
Kashif, Muhammad; Bakar, Ahmad Ashrif A.; Arsad, Norhana; Shaari, Sahbudin
2014-01-01
Surface plasmon resonance (SPR) is a novel optical sensing technique with a unique ability to monitor molecular binding in real-time for biological and chemical sensor applications. Interferometry is an excellent tool for accurate measurement of SPR changes, the measurement and comparison is made for the sensitivity, dynamic range and resolution of the different analytes using interferometry techniques. SPR interferometry can also employ phase detection in addition to the amplitude of the reflected light wave, and the phase changes more rapidly compared with other approaches, i.e., intensity, angle and wavelength. Therefore, the SPR phase interferometer offers the advantages of spatial phase resolution and high sensitivity. This work discusses the advancements in interferometric SPR methods to measure the phase shifts due to refractive index changes. The main application areas of SPR sensors are demonstrated, i.e., the Fabry-Perot interferometer, Michelson interferometer and Mach-Zehnder interferometer, with different configurations. The three interferometers are discussed in detail, and solutions are suggested to enhance the performance parameters that will aid in future biological and chemical sensors. PMID:25171117
Shields, Margaret V; Abdullah, Leath; Namdari, Surena
2016-06-01
Propionibacterium acnes is the most common cause of infection after shoulder arthroplasty. Whereas there are several methods that can aid in the diagnosis of P. acnes infection, there is not a single "gold standard" because of the difficulties inherent in identifying this bacterium. We present an evidence-based discussion of the demographic, clinical, and radiographic predictors of P. acnes infection and review the current options for diagnosis. This review was written after a comprehensive analysis of the current literature related to shoulder periprosthetic joint infection and P. acnes identification. Of the techniques reviewed, α-defensin had the highest sensitivity in detecting P. acnes infection (63%). C-reactive protein level and erythrocyte sedimentation rate were often normal in cases of infection. Whereas P. acnes can be challenging to successfully diagnose, there are several options that are considered preferable because of their higher sensitivities and specificities. The current gold standard is intraoperative culture, but major advances in molecular techniques may provide future improvements in diagnostic accuracy. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Simulation of gas diffusion and sorption in nanoceramic semiconductors
NASA Astrophysics Data System (ADS)
Skouras, E. D.; Burganos, V. N.; Payatakes, A. C.
1999-05-01
Gas diffusion and sorption in nanoceramic semiconductors are studied using atomistic simulation techniques and numerical results are presented for a variety of sorbate-sorbent systems. SnO2, BaTiO3, CuO, and MgO substrates are built on the computer using lattice constants and atomic parameters that have been either measured or computed by ab initio methods. The Universal force field is employed here for the description of both intramolecular and nonbonded interactions for various gas sorbates, including CH4, CO, CO2, and O2, pure and in binary mixtures. Mean residence times are determined by molecular dynamics computations, whereas the Henry constant and the isosteric heat of adsorption are estimated by a Monte Carlo technique. The effects of surface hydroxylation on the diffusion and sorption characteristics are quantified and discussed in view of their significance in practical gas sensing applications. The importance of fast diffusion on the response time of the sensitive layer and of the sorption efficiency on the overall sensitivity as well as the potential synergy of the two phenomena are discussed.
Calvopiña, Manuel; Buendía-Sánchez, María; López-Abán, Julio; Vicente, Belén; Muro, Antonio
2018-01-01
Amphimeriasis, a fish-borne zoonotic disease caused by the liver fluke Amphimerus spp., has recently been reported as an emerging disease affecting an indigenous Ameridian group, the Chachi, living in Ecuador. The only method for diagnosing amphimeriasis was the microscopic detection of eggs from the parasite in patients' stool samples with very low sensitivity. Our group developed an ELISA technique for detection of anti-Amphimerus IgG in human sera and a molecular method based on LAMP technology (named LAMPhimerus) for specific and sensitive parasite DNA detection. The LAMPhimerus method showed to be much more sensitive than classical parasitological methods for amphimeriasis diagnosis using human stool samples for analysis. The objective of this work is to demonstrate the feasibility of using dried stool samples on filter paper as source of DNA in combination with the effectiveness of our previously designed LAMPhimerus assay for successfully Amphimerus sp. detection in clinical stool samples. A total of 102 untreated and undiluted stool samples collected from Chachi population were spread as thin layer onto common filter paper for easily transportation to our laboratory and stored at room temperature for one year until DNA extraction. When LAMPhimerus method was applied for Amphimerus sp. DNA detection, a higher number of positive results was detected (61/102; 59.80%) in comparison to parasitological methods (38/102; 37.25%), including 28/61 (45.90%) microscopy-confirmed Amphimerus sp. infections. The diagnostic parameters for the sensitivity and specificity werecalculated for our LAMPhimerus assay, which were 79.17% and 65.98%, respectively. We demonstrate, for the first time, that common filter paper is useful for easy collection and long-term storage of human stool samples for later DNA extraction and molecular analysis of human-parasitic trematode eggs. This simple, economic and easily handling method combined with the specific and sensible LAMPhimerus assay has the potential to beused as an effective molecular large-scale screening test for amphimeriasis-endemic areas. PMID:29444135
Adegoke, Oluwasesan; Kato, Tatsuya; Park, Enoch Y
2016-06-15
Conventional techniques used to diagnose influenza virus face several challenges, such as low sensitivity, slow detection, false positive results and misinterpreted data. Hence, diagnostic probes that can offer robust detection qualities, such as high sensitivity, rapid detection, elimination of false positive data, and specificity for influenza virus, are urgently needed. The near-infrared (NIR) range is an attractive spectral window due to low photon absorption by biological tissues, hence well-constructed fluorescent biosensors that emit within the NIR window can offer an improved limit of detection (LOD). Here, we demonstrate the use of a newly synthesized NIR quinternary alloyed CdZnSeTeS quantum dots (QDs) as an ultrasensitive fluorescence reporter in a conjugated molecular beacon (MB) assay to detect extremely low concentrations of influenza virus H1N1 RNA. Under optimum conditions, two different strains of influenza virus H1N1 RNA were detected based on fluorescence enhancement signal transduction. We successfully discriminated between two different strains of influenza virus H1N1 RNA based on the number of complementary nucleotide base pairs of the MB to the target RNA sequence. The merits of our bioprobe system are rapid detection, high sensitivity (detects H1N1 viral RNA down to 2 copies/mL), specificity and versatility (detects H1N1 viral RNA in human serum). For comparison, a conventional CdSe/ZnS-MB probe could not detect the extremely low concentrations of H1N1 viral RNA detected by our NIR alloyed CdZnSeTeS-MB probe. Our bioprobe detection system produced a LOD as low as ~1 copy/mL and is more sensitive than conventional molecular tests and rapid influenza detection tests (RIDTS) probes. Copyright © 2016 Elsevier B.V. All rights reserved.
Mohamad, Nurhidayatul Asma; Mustafa, Shuhaimi; Khairil Mokhtar, Nur Fadhilah; El Sheikha, Aly Farag
2018-03-05
The pharmaceutical industry has boosted gelatin consumption worldwide. This is supported by the availability of cost-effective gelatin production from porcine by-products. However, cross-contamination of gelatin materials, where porcine gelatin was unintentionally included in the other animal sources of gelatin, has caused significant concerns about halal authenticity. The real-time polymerase chain reaction (PCR) has enabled a highly specific and sensitive animal species detection method in various food products. Hence, such a technique was employed in the present study to detect and quantify porcine DNA in gelatin using a molecular beacon probe, with differences in performance between mitochondrial (cytochrome b gene) and chromosomal DNA-(MPRE42 repetitive element) based porcine-specific PCR assays being compared. A higher sensitivity was observed in chromosomal DNA (MPRE-PCR assay), where this assay allows the detection of gelatin DNA at amounts as as low as 1 pg, whereas mitochondrial DNA (CBH-PCR assay) can only detect at levels down to 10 pg of gelatin DNA. When an analysis with commercial gelatin and gelatin capsule samples was conducted, the same result was observed, with a significantly more sensitive detection being provided by the repetitive element of chromosomal DNA. The present study has established highly sensitive DNA-based porcine detection systems derived from chromosomal DNA that are feasible for highly processed products such as gelatin and gelatin capsules containing a minute amount of DNA. This sensitive detection method can also be implemented to assist the halal authentication process of various food products available on the market. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Dejous, Corinne; Hallil, Hamida; Raimbault, Vincent; Lachaud, Jean-Luc; Plano, Bernard; Delépée, Raphaël; Favetta, Patrick; Agrofoglio, Luigi; Rebière, Dominique
2016-01-01
Cancer is a leading cause of death worldwide and actual analytical techniques are restrictive in detecting it. Thus, there is still a challenge, as well as a need, for the development of quantitative non-invasive tools for the diagnosis of cancers and the follow-up care of patients. We introduce first the overall interest of electronic nose or tongue for such application of microsensors arrays with data processing in complex media, either gas (e.g., Volatile Organic Compounds or VOCs as biomarkers in breath) or liquid (e.g., modified nucleosides as urinary biomarkers). Then this is illustrated with a versatile acoustic wave transducer, functionalized with molecularly-imprinted polymers (MIP) synthesized for adenosine-5′-monophosphate (AMP) as a model for nucleosides. The device including the thin film coating is described, then static measurements with scanning electron microscopy (SEM) and electrical characterization after each step of the sensitive MIP process (deposit, removal of AMP template, capture of AMP target) demonstrate the thin film functionality. Dynamic measurements with a microfluidic setup and four targets are presented afterwards. They show a sensitivity of 5 Hz·ppm−1 of the non-optimized microsensor for AMP detection, with a specificity of three times compared to PMPA, and almost nil sensitivity to 3′AMP and CMP, in accordance with previously published results on bulk MIP. PMID:27331814
Dejous, Corinne; Hallil, Hamida; Raimbault, Vincent; Lachaud, Jean-Luc; Plano, Bernard; Delépée, Raphaël; Favetta, Patrick; Agrofoglio, Luigi; Rebière, Dominique
2016-06-20
Cancer is a leading cause of death worldwide and actual analytical techniques are restrictive in detecting it. Thus, there is still a challenge, as well as a need, for the development of quantitative non-invasive tools for the diagnosis of cancers and the follow-up care of patients. We introduce first the overall interest of electronic nose or tongue for such application of microsensors arrays with data processing in complex media, either gas (e.g., Volatile Organic Compounds or VOCs as biomarkers in breath) or liquid (e.g., modified nucleosides as urinary biomarkers). Then this is illustrated with a versatile acoustic wave transducer, functionalized with molecularly-imprinted polymers (MIP) synthesized for adenosine-5'-monophosphate (AMP) as a model for nucleosides. The device including the thin film coating is described, then static measurements with scanning electron microscopy (SEM) and electrical characterization after each step of the sensitive MIP process (deposit, removal of AMP template, capture of AMP target) demonstrate the thin film functionality. Dynamic measurements with a microfluidic setup and four targets are presented afterwards. They show a sensitivity of 5 Hz·ppm(-1) of the non-optimized microsensor for AMP detection, with a specificity of three times compared to PMPA, and almost nil sensitivity to 3'AMP and CMP, in accordance with previously published results on bulk MIP.
DNA Methyltransferase Activity Assays: Advances and Challenges
Poh, Wan Jun; Wee, Cayden Pang Pee; Gao, Zhiqiang
2016-01-01
DNA methyltransferases (MTases), a family of enzymes that catalyse the methylation of DNA, have a profound effect on gene regulation. A large body of evidence has indicated that DNA MTase is potentially a predictive biomarker closely associated with genetic disorders and genetic diseases like cancer. Given the attention bestowed onto DNA MTases in molecular biology and medicine, highly sensitive detection of DNA MTase activity is essential in determining gene regulation, epigenetic modification, clinical diagnosis and therapeutics. Conventional techniques such as isotope labelling are effective, but they often require laborious sample preparation, isotope labelling, sophisticated equipment and large amounts of DNA, rendering them unsuitable for uses at point-of-care. Simple, portable, highly sensitive and low-cost assays are urgently needed for DNA MTase activity screening. In most recent technological advances, many alternative DNA MTase activity assays such as fluorescent, electrochemical, colorimetric and chemiluminescent assays have been proposed. In addition, many of them are coupled with nanomaterials and/or enzymes to significantly enhance their sensitivity. Herein we review the progress in the development of DNA MTase activity assays with an emphasis on assay mechanism and performance with some discussion on challenges and perspectives. It is hoped that this article will provide a broad coverage of DNA MTase activity assays and their latest developments and open new perspectives toward the development of DNA MTase activity assays with much improved performance for uses in molecular biology and clinical practice. PMID:26909112
Ale, Angelique; Ermolayev, Vladimir; Deliolanis, Nikolaos C; Ntziachristos, Vasilis
2013-05-01
The ability to visualize early stage lung cancer is important in the study of biomarkers and targeting agents that could lead to earlier diagnosis. The recent development of hybrid free-space 360-deg fluorescence molecular tomography (FMT) and x-ray computed tomography (XCT) imaging yields a superior optical imaging modality for three-dimensional small animal fluorescence imaging over stand-alone optical systems. Imaging accuracy was improved by using XCT information in the fluorescence reconstruction method. Despite this progress, the detection sensitivity of targeted fluorescence agents remains limited by nonspecific background accumulation of the fluorochrome employed, which complicates early detection of murine cancers. Therefore we examine whether x-ray CT information and bulk fluorescence detection can be combined to increase detection sensitivity. Correspondingly, we research the performance of a data-driven fluorescence background estimator employed for subtraction of background fluorescence from acquisition data. Using mice containing known fluorochromes ex vivo, we demonstrate the reduction of background signals from reconstructed images and sensitivity improvements. Finally, by applying the method to in vivo data from K-ras transgenic mice developing lung cancer, we find small tumors at an early stage compared with reconstructions performed using raw data. We conclude with the benefits of employing fluorescence subtraction in hybrid FMT-XCT for early detection studies.
Mohon, Abu Naser; Elahi, Rubayet; Khan, Wasif A; Haque, Rashidul; Sullivan, David J; Alam, Mohammad Shafiul
2014-06-01
Molecular diagnosis of malaria by nucleotide amplification requires sophisticated and expensive instruments, typically found only in well-established laboratories. Loop-mediated isothermal amplification (LAMP) has provided a new platform for an easily adaptable molecular technique for molecular diagnosis of malaria without the use of expensive instruments. A new primer set has been designed targeting the 18S rRNA gene for the detection of Plasmodium falciparum in whole blood samples. The efficacy of LAMP using the new primer set was assessed in this study in comparison to that of a previously described set of LAMP primers as well as with microscopy and real-time PCR as reference methods for detecting P. falciparum. Pre-addition of hydroxy napthol blue (HNB) in the LAMP reaction caused a distinct color change, thereby improving the visual detection system. The new LAMP assay was found to be 99.1% sensitive compared to microscopy and 98.1% when compared to real-time PCR. Meanwhile, its specificity was 99% and 100% in contrast to microscopy and real-time PCR, respectively. Moreover, the LAMP method was in very good agreement with microscopy and real-time PCR (0.94 and 0.98, respectively). This new LAMP method can detect at least 5parasites/μL of infected blood within 35min, while the other LAMP method tested in this study, could detect a minimum of 100parasites/μL of human blood after 60min of amplification. Thus, the new method is sensitive and specific, can be carried out in a very short time, and can substitute PCR in healthcare clinics and standard laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
Light Assisted IN-VIVO Microwave Sensing for Electrical Characterization of Prokaryotes
NASA Astrophysics Data System (ADS)
Sharma, Rajveer; Daya, K. S.; Tirumalai, Prem Saran
2012-11-01
This paper reports an in vivo characterization technique to characterize dielectric properties of living tissues and bio-molecules at microwave frequency using cavity perturbation technique, where a slot ring resonant sensor has been used, that works at 8 GHz and has been designed to enumerate the effective dielectric constant of Spirulina platensis and chlorophyll molecule. Observed value of the dielectric constant of Spirulina platensis was 8 ± 0.04 in the absence of light and 14.575 ± 0.145 in the presence of light. Molecular polarizability of chl a molecule was 5.07 ± 0.05 × 104 Å3. Experimentally calculated local electric field actually experienced by chl a molecule was 14.197 ± 0.003 V/m for applied field of 9.79 V/m across the slot ring, dipole moment of chl a molecule was 2.175 ± 0.005 × 105 Debye and total polarisation produced due to these molecules was 1.545 ± 0.005 C/m2. Observed relaxation time of chl a molecule was 8.09 ± 0.18 × 10-9s. The proposed sensing method can be an alternate to spectral characterisation technique, generally used to characterize light sensitive bio-molecules and can also be extended to characterize light sensitive bio-molecules in plant cells.
Tang, Feng; Cen, Si-Ying; He, Huan; Liu, Yi; Yuan, Bi-Feng; Feng, Yu-Qi
2016-05-23
Determination of low-molecular-weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been a great challenge in the analytical research field. Here we developed a universal peptide-based derivatization (peptidylation) strategy for the sensitive analysis of low-molecular-weight compounds by MALDI-TOF-MS. Upon peptidylation, the molecular weights of target analytes increase, thus avoiding serious matrix ion interference in the low-molecular-weight region in MALDI-TOF-MS. Since peptides typically exhibit good signal response during MALDI-TOF-MS analysis, peptidylation endows high detection sensitivities of low-molecular-weight analytes. As a proof-of-concept, we analyzed low-molecular-weight compounds of aldehydes and thiols by the developed peptidylation strategy. Our results showed that aldehydes and thiols can be readily determined upon peptidylation, thus realizing the sensitive and efficient determination of low-molecular-weight compounds by MALDI-TOF-MS. Moreover, target analytes also can be unambiguously detected in biological samples using the peptidylation strategy. The established peptidylation strategy is a universal strategy and can be extended to the sensitive analysis of various low-molecular-weight compounds by MALDI-TOF-MS, which may be potentially used in areas such as metabolomics.
Longitudinal molecular characterization of endoscopic specimens from colorectal lesions
Minarikova, Petra; Benesova, Lucie; Halkova, Tereza; Belsanova, Barbora; Suchanek, Stepan; Cyrany, Jiri; Tuckova, Inna; Bures, Jan; Zavoral, Miroslav; Minarik, Marek
2016-01-01
AIM: To compare molecular profiles of proximal colon, distal colon and rectum in large adenomas, early and late carcinomas. To assess feasibility of testing directed at molecular markers from this study in routine clinical practice. METHODS: A prospective 3-year study has resulted in the acquisition of samples from 159 large adenomas and 138 carcinomas along with associated clinical parameters including localization, grade and histological type for adenomas and localization and stage for carcinomas. A complex molecular phenotyping has been performed using multiplex ligation-dependent probe amplification technique for the evaluation of CpG-island methylator phenotype (CIMP), PCR fragment analysis for detection of microsatellite instability and denaturing capillary electrophoresis for sensitive detection of somatic mutations in KRAS, BRAF, TP53 and APC genes. RESULTS: Molecular types according to previously introduced Jass classification have been evaluated for large adenomas and early and late carcinomas. An increase in CIMP+ type, eventually accompanied with KRAS mutations, was notable between large adenomas and early carcinomas. As expected, the longitudinal observations revealed a correlation of the CIMP+/BRAF+ type with proximal location. CONCLUSION: Prospective molecular classification of tissue specimens is feasible in routine endoscopy practice. Increased frequency of some molecular types corresponds to the developmental stages of colorectal tumors. As expected, a clear distinction is notable for tumors located in proximal colon supposedly arising from the serrated (methylation) pathway. PMID:27239120
LAMPhimerus: A novel LAMP assay for detecting Amphimerus sp. DNA in human stool samples
Calvopiña, Manuel; Fontecha-Cuenca, Cristina; Sugiyama, Hiromu; Sato, Megumi; López Abán, Julio; Vicente, Belén; Muro, Antonio
2017-01-01
Background Amphimeriasis is a fish-borne disease caused by the liver fluke Amphimerus spp. that has recently been reported as endemic in the tropical Pacific side of Ecuador with a high prevalence in humans and domestic animals. The diagnosis is based on the stool examination to identify parasite eggs, but it lacks sensitivity. Additionally, the morphology of the eggs may be confounded with other liver and intestinal flukes. No immunological or molecular methods have been developed to date. New diagnostic techniques for specific and sensitive detection of Amphimerus spp. DNA in clinical samples are needed. Methodology/Principal findings A LAMP targeting a sequence of the Amphimerus sp. internal transcribed spacer 2 region was designed. Amphimerus sp. DNA was obtained from adult worms recovered from animals and used to optimize the molecular assays. Conventional PCR was performed using outer primers F3-B3 to verify the proper amplification of the Amphimerus sp. DNA target sequence. LAMP was optimized using different reaction mixtures and temperatures, and it was finally set up as LAMPhimerus. The specificity and sensitivity of both PCR and LAMP were evaluated. The detection limit was 1 pg of genomic DNA. Field testing was done using 44 human stool samples collected from localities where fluke is endemic. Twenty-five samples were microscopy positive for Amphimerus sp. eggs detection. In molecular testing, PCR F3-B3 was ineffective when DNA from fecal samples was used. When testing all human stool samples included in our study, the diagnostic parameters for the sensitivity and specificity were calculated for our LAMPhimerus assay, which were 76.67% and 80.77%, respectively. Conclusions/Significance We have developed and evaluated, for the first time, a specific and sensitive LAMP assay for detecting Amphimerus sp. in human stool samples. The procedure has been named LAMPhimerus method and has the potential to be adapted for field diagnosis and disease surveillance in amphimeriasis-endemic areas. Future large-scale studies will assess the applicability of this novel LAMP assay. PMID:28628614
Coherent Anti-Stokes Raman Scattering Spectroscopy of Single Molecules in Solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunney Xie, Wei Min, Chris Freudiger, Sijia Lu
2012-01-18
During this funding period, we have developed two breakthrough techniques. The first is stimulated Raman scattering microscopy, providing label-free chemical contrast for chemical and biomedical imaging based on vibrational spectroscopy. Spontaneous Raman microscopy provides specific vibrational signatures of chemical bonds, but is often hindered by low sensitivity. We developed a three-dimensional multiphoton vibrational imaging technique based on stimulated Raman scattering (SRS). The sensitivity of SRS imaging is significantly greater than that of spontaneous Raman microscopy, which is achieved by implementing high-frequency (megahertz) phase-sensitive detection. SRS microscopy has a major advantage over previous coherent Raman techniques in that it offers background-freemore » and readily interpretable chemical contrast. We demonstrated a variety of biomedical applications, such as differentiating distributions of omega-3 fatty acids and saturated lipids in living cells, imaging of brain and skin tissues based on intrinsic lipid contrast, and monitoring drug delivery through the epidermis. This technology offers exciting prospect for medical imaging. The second technology we developed is stimulated emission microscopy. Many chromophores, such as haemoglobin and cytochromes, absorb but have undetectable fluorescence because the spontaneous emission is dominated by their fast non-radiative decay. Yet the detection of their absorption is difficult under a microscope. We use stimulated emission, which competes effectively with the nonradiative decay, to make the chromophores detectable, as a new contrast mechanism for optical microscopy. We demonstrate a variety of applications of stimulated emission microscopy, such as visualizing chromoproteins, non-fluorescent variants of the green fluorescent protein, monitoring lacZ gene expression with a chromogenic reporter, mapping transdermal drug distribu- tions without histological sectioning, and label-free microvascular imaging based on endogenous contrast of haemoglobin. For all these applications, sensitivity is orders of magnitude higher than for spontaneous emission or absorption contrast, permitting nonfluorescent reporters for molecular imaging. Although we did not accomplish the original goal of detecting single-molecule by CARS, our quest for high sensitivity of nonlinear optical microscopy paid off in providing the two brand new enabling technologies. Both techniques were greatly benefited from the use of high frequency modulation for microscopy, which led to orders of magnitude increase in sensitivity. Extensive efforts have been made on optics and electronics to accomplish these breakthroughs.« less
Rai, Keshav; Bhattarai, Narayan Raj; Agarwal, Sudha; Khanal, Basudha
2016-01-01
Background Detection of Mycobacterium leprae in slit skin smear (SSS) is a gold standard technique for the leprosy diagnosis. Over recent years, molecular diagnosis by using PCR has been increasingly used as an alternative for its diagnosis due to its higher sensitivity. This study was carried out for comparative evaluation of PCR and SSS microscopy in a cohort of new leprosy cases diagnosed in B. P. Koirala Institute of health Sciences, Dharan, Nepal. Methodology/Principal Findings In this prospective crossectional study, 50 new clinically diagnosed cases of leprosy were included. DNA was extracted from SSS and PCR was carried out to amplify 129 bp sequence of M. leprae repetitive element. Sensitivity of SSS and PCR was 18% and 72% respectively. Improvement of 54% case detection by PCR clearly showed its advantage over SSS. Furthermore, PCR could confirm the leprosy diagnosis in 66% of AFB negative cases indicating its superiority over SSS. In the paucibacillary (PB) patients, whose BI was zero; sensitivity of PCR was 44%, whereas it was 78% in the multibacillary patients. Conclusions/Significance Our study showed PCR to be more sensitive than SSS microscopy in diagnosing leprosy. Moreover, it explored the characteristic feature of PCR which detected higher level of early stage(PB) cases tested negative by SSS. Being an expensive technique, PCR may not be feasible in all the cases, however, it would be useful in diagnosis of early cases of leprosy as opposed to SSS. PMID:28027305
Siwakoti, Shraddha; Rai, Keshav; Bhattarai, Narayan Raj; Agarwal, Sudha; Khanal, Basudha
2016-12-01
Detection of Mycobacterium leprae in slit skin smear (SSS) is a gold standard technique for the leprosy diagnosis. Over recent years, molecular diagnosis by using PCR has been increasingly used as an alternative for its diagnosis due to its higher sensitivity. This study was carried out for comparative evaluation of PCR and SSS microscopy in a cohort of new leprosy cases diagnosed in B. P. Koirala Institute of health Sciences, Dharan, Nepal. In this prospective crossectional study, 50 new clinically diagnosed cases of leprosy were included. DNA was extracted from SSS and PCR was carried out to amplify 129 bp sequence of M. leprae repetitive element. Sensitivity of SSS and PCR was 18% and 72% respectively. Improvement of 54% case detection by PCR clearly showed its advantage over SSS. Furthermore, PCR could confirm the leprosy diagnosis in 66% of AFB negative cases indicating its superiority over SSS. In the paucibacillary (PB) patients, whose BI was zero; sensitivity of PCR was 44%, whereas it was 78% in the multibacillary patients. Our study showed PCR to be more sensitive than SSS microscopy in diagnosing leprosy. Moreover, it explored the characteristic feature of PCR which detected higher level of early stage(PB) cases tested negative by SSS. Being an expensive technique, PCR may not be feasible in all the cases, however, it would be useful in diagnosis of early cases of leprosy as opposed to SSS.
Bruno, William; Martinuzzi, Claudia; Andreotti, Virginia; Pastorino, Lorenza; Spagnolo, Francesco; Dalmasso, Bruna; Cabiddu, Francesco; Gualco, Marina; Ballestrero, Alberto; Bianchi-Scarrà, Giovanna; Queirolo, Paola
2017-01-01
Finding the best technique to identify BRAF mutations with a high sensitivity and specificity is mandatory for accurate patient selection for target therapy. BRAF mutation frequency ranges from 40 to 60% depending on melanoma clinical characteristics and detection technique used. Intertumoral heterogeneity could lead to misinterpretation of BRAF mutational status; this is especially important if testing is performed on primary specimens, when metastatic lesions are unavailable. Aim of this study was to identify the best combination of methods for detecting BRAF mutations (among peptide nucleic acid – PNA-clamping real-time PCR, immunohistochemistry and capillary sequencing) and investigate BRAF mutation heterogeneity in a series of 100 primary melanomas and a subset of 25 matched metastatic samples. Overall, we obtained a BRAF mutation frequency of 62%, based on the combination of at least two techniques. Concordance between mutation status in primary and metastatic tumor was good but not complete (67%), when agreement of at least two techniques were considered. Next generation sequencing was used to quantify the threshold of detected mutant alleles in discordant samples. Combining different methods excludes that the observed heterogeneity is technique-based. We propose an algorithm for BRAF mutation testing based on agreement between immunohistochemistry and PNA; a third molecular method could be added in case of discordance of the results. Testing the primary tumor when the metastatic sample is unavailable is a good option if at least two methods of detection are used, however the presence of intertumoral heterogeneity or the occurrence of additional primaries should be carefully considered. PMID:28039443
Morphology-Driven Control of Metabolite Selectivity Using Nanostructure-Initiator Mass Spectrometry
Gao, Jian; Louie, Katherine B.; Steinke, Philipp; ...
2017-05-26
Nanostructure-initiator mass spectrometry (NIMS) is a laser desorption/ionization analysis technique based on the vaporization of a nanostructure-trapped liquid "initiator" phase. Here we report an intriguing relationship between NIMS surface morphology and analyte selectivity. Scanning electron microscopy and spectroscopic ellipsometry were used to characterize the surface morphologies of a series of NIMS substrates generated by anodic electrochemical etching. Mass spectrometry imaging was applied to compare NIMS sensitivity of these various surfaces toward the analysis of diverse analytes. The porosity of NIMS surfaces was found to increase linearly with etching time where the pore size ranged from 4 to 12 nm withmore » corresponding porosities estimated to be 7-70%. Surface morphology was found to significantly and selectively alter NIMS sensitivity. The small molecule ( < 2k Da) sensitivity was found to increase with increased porosity, whereas low porosity had the highest sensitivity for the largest molecules examined. Estimation of molecular sizes showed that this transition occurs when the pore size is < 3× the maximum of molecular dimensions. While the origins of selectivity are unclear, increased signal from small molecules with increased surface area is consistent with a surface area restructuring-driven desorption/ionization process where signal intensity increases with porosity. In contrast, large molecules show highest signal for the low-porosity and small-pore-size surfaces. We attribute this to strong interactions between the initiator-coated pore structures and large molecules that hinder desorption/ionization by trapping large molecules. This finding may enable us to design NIMS surfaces with increased specificity to molecules of interest.« less
Martinuzzi, Claudia; Pastorino, Lorenza; Andreotti, Virginia; Garuti, Anna; Minuto, Michele; Fiocca, Roberto; Bianchi-Scarrà, Giovanna; Ghiorzo, Paola; Grillo, Federica; Mastracci, Luca
2016-09-01
The optimal method for BRAF mutation detection remains to be determined despite advances in molecular detection techniques. The aim of this study was to compare, against classical Sanger sequencing, the diagnostic performance of two of the most recently developed, highly sensitive methods: BRAF V600E immunohistochemistry (IHC) and peptide nucleic-acid (PNA)-clamp qPCR. BRAF exon 15 mutations were searched in formalin-fixed paraffin-embedded tissues from 86 papillary thyroid carcinoma using the three methods. The limits of detection of Sanger sequencing in borderline or discordant cases were quantified by next generation sequencing. BRAF mutations were found in 74.4 % of cases by PNA, in 71 % of cases by IHC, and in 64 % of cases by Sanger sequencing. Complete concordance for the three methods was observed in 80 % of samples. Better concordance was observed with the combination of two methods, particularly PNA and IHC (59/64) (92 %), while the combination of PNA and Sanger was concordant in 55 cases (86 %). Sensitivity of the three methods was 99 % for PNA, 94.2 % for IHC, and 89.5 % for Sanger. Our data show that IHC could be used as a cost-effective, first-line method for BRAF V600E detection in daily practice, followed by PNA analysis in negative or uninterpretable cases, as the most efficient method. PNA-clamp quantitative PCR is highly sensitive and complementary to IHC as it also recognizes other mutations besides V600E and it is suitable for diagnostic purposes.
Development of a fast and efficient method for hepatitis A virus concentration from green onion.
Zheng, Yan; Hu, Yuan
2017-11-01
Hepatitis A virus (HAV) can cause serious liver disease and even death. HAV outbreaks are associated with the consumption of raw or minimally processed produce, making it a major public health concern. Infections have occurred despite the fact that effective HAV vaccine has been available. Development of a rapid and sensitive HAV detection method is necessary for an investigation of an HAV outbreak. Detection of HAV is complicated by the lack of a reliable culture method. In addition, due to the low infectious dose of HAV, these methods must be very sensitive. Current methods rely on efficient sample preparation and concentration steps followed by sensitive molecular detection techniques. Using green onions which was involved in most recent HAV outbreaks as a representative produce, a method of capturing virus particles was developed using carboxyl-derivatized magnetic beads in this study. Carboxyl beads, like antibody-coated beads or cationic beads, detect HAV at a level as low as 100 pfu/25g of green onions. RNA from virus concentrated in this manner can be released by heat-shock (98°C 5min) for molecular detection without sacrificing sensitivity. Bypassing the RNA extraction procedure saves time and removes multiple manipulation steps, which makes large scale HAV screening possible. In addition, the inclusion of beef extract and pectinase rather than NP40 in the elution buffer improved the HAV liberation from the food matrix over current methods by nearly 10 fold. The method proposed in this study provides a promising tool to improve food risk assessment and protect public health. Published by Elsevier B.V.
Fluorescent probes for real-time measurement of nitric oxide in living cells.
Li, Huili; Wan, Ajun
2015-11-07
Nitric oxide (NO) is an important signaling molecule in biology. Both NO excess and insufficiency have been implicated in numerous physiological and pathological conditions. In order to study the diverse biological roles of NO in cells and tissues, many techniques have been developed for assaying NO. Recently, new generations of fluorescent probes have become indispensible tools for the study of NO biology because of their sensitivity, selectivity, spatiotemporal resolution, and experimental feasibility. Rational application of these probes in the study requires the understanding of the molecular mechanism that the probes are involved in. In this review, we will present an arsenal of fluorescent probes used to detect NO in living cells and animal tissues. We will also discuss the molecular mechanisms, actualities and prospects of fluorescent probes in detecting NO in cell biology.
NASA Astrophysics Data System (ADS)
Hartmann, Jean-Michel; Tran, Ha; Armante, Raymond; Boulet, Christian; Campargue, Alain; Forget, François; Gianfrani, Livio; Gordon, Iouli; Guerlet, Sandrine; Gustafsson, Magnus; Hodges, Joseph T.; Kassi, Samir; Lisak, Daniel; Thibault, Franck; Toon, Geoffrey C.
2018-07-01
We review progress, since publication of the book ``Collisional effects on molecular spectra: Laboratory experiments and models, consequences for applications" (Elsevier, Amsterdam, 2008), on measuring, modeling and predicting the influence of pressure (ie of intermolecular collisions) on the spectra of gas molecules. We first introduce recently developed experimental techniques of high accuracy and sensitivity. We then complement the aforementioned book by presenting the theoretical approaches, results and data proposed (mostly) in the last decade on the topics of isolated line shapes, line-broadening and -shifting, line-mixing, the far wings and associated continua, and collision-induced absorption. Examples of recently demonstrated consequences of the progress in the description of spectral shapes for some practical applications (metrology, probing of gas media, climate predictions) are then given. Remaining issues and directions for future research are finally discussed.
Kaastrup, Kaja; Sikes, Hadley D
2012-10-21
Although polymerization-based amplification (PBA) has demonstrated promise as an inexpensive technique for use in molecular diagnostics, oxygen inhibition of radical photopolymerization has hindered its implementation in point-of-care devices. The addition of 0.3-0.7 μM eosin to an aqueous acrylate monomer solution containing a tertiary amine allows an interfacial polymerization reaction to proceed in air only near regions of a test surface where additional eosin initiators coupled to proteins have been localized as a function of molecular recognition events. The dose of light required for the reaction is inversely related to eosin concentration. This system achieves sensitivities comparable to those reported for inert gas-purged systems and requires significantly shorter reaction times. We provide several comparisons of this system with other implementations of polymerization-based amplification.
Voltage-Driven Conformational Switching with Distinct Raman Signature in a Single-Molecule Junction.
Bi, Hai; Palma, Carlos-Andres; Gong, Yuxiang; Hasch, Peter; Elbing, Mark; Mayor, Marcel; Reichert, Joachim; Barth, Johannes V
2018-04-11
Precisely controlling well-defined, stable single-molecule junctions represents a pillar of single-molecule electronics. Early attempts to establish computing with molecular switching arrays were partly challenged by limitations in the direct chemical characterization of metal-molecule-metal junctions. While cryogenic scanning probe studies have advanced the mechanistic understanding of current- and voltage-induced conformational switching, metal-molecule-metal conformations are still largely inferred from indirect evidence. Hence, the development of robust, chemically sensitive techniques is instrumental for advancement in the field. Here we probe the conformation of a two-state molecular switch with vibrational spectroscopy, while simultaneously operating it by means of the applied voltage. Our study emphasizes measurements of single-molecule Raman spectra in a room-temperature stable single-molecule switch presenting a signal modulation of nearly 2 orders of magnitude.
Probe-based measurement of lateral single-electron transfer between individual molecules
Steurer, Wolfram; Fatayer, Shadi; Gross, Leo; Meyer, Gerhard
2015-01-01
The field of molecular electronics aims at using single molecules as functional building blocks for electronics components, such as switches, rectifiers or transistors. A key challenge is to perform measurements with atomistic control over the alignment of the molecule and its contacting electrodes. Here we use atomic force microscopy to examine charge transfer between weakly coupled pentacene molecules on insulating films with single-electron sensitivity and control over the atomistic details. We show that, in addition to the imaging capability, the probe tip can be used to control the charge state of individual molecules and to detect charge transfers to/from the tip, as well as between individual molecules. Our approach represents a novel route for molecular charge transfer studies with a host of opportunities, especially in combination with single atom/molecule manipulation and nanopatterning techniques. PMID:26387533
Niemeyer, D M; Jaffe, R I; Wiggins, L B
2000-11-01
At present, the use of molecular probes and polymerase chain reaction (PCR) for the identification of microorganisms in body fluids or tissues is becoming more commonplace. There is an added advantage when serological or culture methods are difficult, expensive, or unavailable. Slow-growing or fastidious microorganisms, including Mycobacterium tuberculosis, spirochetes, viruses, and the dimorphic fungi, can be detected rapidly using these techniques. The presence of different chromosomal or plasmid-mediated antibiotic-resistant markers can also be determined. PCR is an extremely powerful tool that has been applied to research, and more recently it has been used to augment standard clinical applications. It is a very simple process that can amplify nucleic acid sequences, both DNA and RNA, a million times over. The sensitivity, rapidity, broad applicability, and compactness of this technology make it an ideal candidate for use in the military arena. We recently established a molecular biology laboratory at a Deployable Medical System at the Camp Parks Army Reserve Training Facility in Dublin, California. This article will briefly summarize the use of PCR and its applicability in the air-transportable hospital field environment. Proper handling, processing, and testing as well as the requirements for setting up a molecular biology laboratory will be discussed. Finally, the benefits and disadvantages of using PCR-based techniques in the deployed field environment will be considered.
Kostal, Jakub; Voutchkova-Kostal, Adelina
2016-01-19
Using computer models to accurately predict toxicity outcomes is considered to be a major challenge. However, state-of-the-art computational chemistry techniques can now be incorporated in predictive models, supported by advances in mechanistic toxicology and the exponential growth of computing resources witnessed over the past decade. The CADRE (Computer-Aided Discovery and REdesign) platform relies on quantum-mechanical modeling of molecular interactions that represent key biochemical triggers in toxicity pathways. Here, we present an external validation exercise for CADRE-SS, a variant developed to predict the skin sensitization potential of commercial chemicals. CADRE-SS is a hybrid model that evaluates skin permeability using Monte Carlo simulations, assigns reactive centers in a molecule and possible biotransformations via expert rules, and determines reactivity with skin proteins via quantum-mechanical modeling. The results were promising with an overall very good concordance of 93% between experimental and predicted values. Comparison to performance metrics yielded by other tools available for this endpoint suggests that CADRE-SS offers distinct advantages for first-round screenings of chemicals and could be used as an in silico alternative to animal tests where permissible by legislative programs.
Schweitzer, Mary Higby; Schroeter, Elena R; Goshe, Michael B
2014-07-15
Advances in resolution and sensitivity of analytical techniques have provided novel applications, including the analyses of fossil material. However, the recovery of original proteinaceous components from very old fossil samples (defined as >1 million years (1 Ma) from previously named limits in the literature) is far from trivial. Here, we discuss the challenges to recovery of proteinaceous components from fossils, and the need for new sample preparation techniques, analytical methods, and bioinformatics to optimize and fully utilize the great potential of information locked in the fossil record. We present evidence for survival of original components across geological time, and discuss the potential benefits of recovery, analyses, and interpretation of fossil materials older than 1 Ma, both within and outside of the fields of evolutionary biology.
Fang, Ching; Liu, Ju-Tsung; Lin, Cheng-Huang
2003-03-01
This work describes a novel method for the accurate determination of lysergic acid diethylamide (LSD) in tablets. A technique involving sweeping-micellar electrokinetic chromatography (MEKC) was used for the initial on-line concentration and separation, after which a cryogenic molecular fluorescence experiment was performed at 77 K. Using this approach, not only the separation of LSD from the tablet extract was achieved, but on-line spectra were readily distinguishable and could be unambiguously assigned. The results are in agreement with analyses by gas chromatography-mass spectrometry (GC-MS). Thus, this method, which was found to be accurate, sensitive and rapid, has the potential for use as a reliable complementary method to GC-MS in such analyses.
Progress in the detection of neoplastic progress and cancer by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Bakker Schut, Tom C.; Stone, Nicholas; Kendall, Catherine A.; Barr, Hugh; Bruining, Hajo A.; Puppels, Gerwin J.
2000-05-01
Early detection of cancer is important because of the improved survival rates when the cancer is treated early. We study the application of NIR Raman spectroscopy for detection of dysplasia because this technique is sensitive to the small changes in molecular invasive in vivo detection using fiber-optic probes. The result of an in vitro study to detect neoplastic progress of esophageal Barrett's esophageal tissue will be presented. Using multivariate statistics, we developed three different linear discriminant analysis classification models to predict tissue type on the basis of the measured spectrum. Spectra of normal, metaplastic and dysplasia tissue could be discriminated with an accuracy of up to 88 percent. Therefore Raman spectroscopy seems to be a very suitable technique to detect dysplasia in Barrett's esophageal tissue.
Elemental and isotopic imaging of biological samples using NanoSIMS.
Kilburn, Matt R; Clode, Peta L
2014-01-01
With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.
Ultrabroadband infrared nanospectroscopic imaging
Bechtel, Hans A.; Muller, Eric A.; Olmon, Robert L.; Martin, Michael C.; Raschke, Markus B.
2014-01-01
Characterizing and ultimately controlling the heterogeneity underlying biomolecular functions, quantum behavior of complex matter, photonic materials, or catalysis requires large-scale spectroscopic imaging with simultaneous specificity to structure, phase, and chemical composition at nanometer spatial resolution. However, as with any ultrahigh spatial resolution microscopy technique, the associated demand for an increase in both spatial and spectral bandwidth often leads to a decrease in desired sensitivity. We overcome this limitation in infrared vibrational scattering-scanning probe near-field optical microscopy using synchrotron midinfrared radiation. Tip-enhanced localized light–matter interaction is induced by low-noise, broadband, and spatially coherent synchrotron light of high spectral irradiance, and the near-field signal is sensitively detected using heterodyne interferometric amplification. We achieve sub-40-nm spatially resolved, molecular, and phonon vibrational spectroscopic imaging, with rapid spectral acquisition, spanning the full midinfrared (700–5,000 cm−1) with few cm−1 spectral resolution. We demonstrate the performance of synchrotron infrared nanospectroscopy on semiconductor, biomineral, and protein nanostructures, providing vibrational chemical imaging with subzeptomole sensitivity. PMID:24803431
Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.
Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias
2012-12-01
Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.
Charge-transfer-based terbium MOF nanoparticles as fluorescent pH sensor for extreme acidity.
Qi, Zewan; Chen, Yang
2017-01-15
Newly emerged metal organic frameworks (MOFs) have aroused the great interest in designing functional materials by means of its flexible structure and component. In this study, we used lanthanide Tb 3+ ions and small molecular ligands to design and assemble a kind of pH-sensitive MOF nanoparticle based on intramolecular-charge-transfer effect. This kind of made-to-order MOF nanoparticle for H + is highly specific and sensitive and could be used to fluorescently indicate pH value of strong acidic solution via preset mechanism through luminescence of Tb 3+ . The long luminescence lifetime of Tb 3+ allows eliminating concomitant non-specific fluorescence by time-revised fluorescence techniques, processing an advantage in sensing H + in biological media with strong autofluorescence. Our method showed a great potential of MOF structures in designing and constructing sensitive sensing materials for specific analytes directly via the assembly of functional ions/ligands. Copyright © 2016 Elsevier B.V. All rights reserved.
Streby, Ashleigh; Mull, Bonnie J; Levy, Karen; Hill, Vincent R
2015-05-01
Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Foursuch assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices.
Streby, Ashleigh; Mull, Bonnie J.; Levy, Karen
2015-01-01
Naegleria fowleri is a thermophilic free-living ameba found in freshwater environments worldwide. It is the cause of a rare but potentially fatal disease in humans known as primary amebic meningoencephalitis. Established N. fowleri detection methods rely on conventional culture techniques and morphological examination followed by molecular testing. Multiple alternative real-time PCR assays have been published for rapid detection of Naegleria spp. and N. fowleri. Four such assays were evaluated for the detection of N. fowleri from surface water and sediment. The assays were compared for thermodynamic stability, analytical sensitivity and specificity, detection limits, humic acid inhibition effects, and performance with seeded environmental matrices. Twenty-one ameba isolates were included in the DNA panel used for analytical sensitivity and specificity analyses. N. fowleri genotypes I and III were used for method performance testing. Two of the real-time PCR assays were determined to yield similar performance data for specificity and sensitivity for detecting N. fowleri in environmental matrices. PMID:25855343
Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui
2017-01-01
Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation. PMID:29084241
Muramoto, Shin; Brison, Jeremy; Castner, David G.
2011-01-01
The surface sensitivity of Binq+ (n = 1, 3, 5, q = 1, 2) and C60q+ (q = 1, 2) primary ions in static time-of-flight secondary ion mass spectrometry (ToF-SIMS) experiments were investigated for molecular trehalose and polymeric tetraglyme organic films. Parameters related to surface sensitivity (impact crater depth, implantation depth, and molecular escape depths) were measured. Under static ToF-SIMS conditions (primary ion doses of 1 × 1012 ions/cm2), the 25 keV Bi1+ primary ions were the most surface sensitive with a molecular escape depth of 1.8 nm for protein films with tetraglyme overlayers, but they had the deepest implantation depth (~18 and 26 nm in trehalose and tetraglyme films, respectively). The 20 keV C60++ primary ions were the second most surface sensitive with a slightly larger molecular escape depth of 2.3 nm. The most important factor that determined the surface sensitivity of the primary ion was its impact crater depth, or the amount of surface erosion. The most surface sensitive primary ions, Bi1+ and C60++, created impact craters with depths of 0.3 and 1.0 nm, respectively, in tetraglyme films. In contrast, Bi5++ primary ions created impact craters with a depth of 1.8 nm in tetraglyme films and were the least surface sensitive with a molecular escape depth of 4.7 nm. PMID:22084828
High-resolution magnetic resonance spectroscopy using a solid-state spin sensor
NASA Astrophysics Data System (ADS)
Glenn, David R.; Bucher, Dominik B.; Lee, Junghyun; Lukin, Mikhail D.; Park, Hongkun; Walsworth, Ronald L.
2018-03-01
Quantum systems that consist of solid-state electronic spins can be sensitive detectors of nuclear magnetic resonance (NMR) signals, particularly from very small samples. For example, nitrogen–vacancy centres in diamond have been used to record NMR signals from nanometre-scale samples, with sensitivity sufficient to detect the magnetic field produced by a single protein. However, the best reported spectral resolution for NMR of molecules using nitrogen–vacancy centres is about 100 hertz. This is insufficient to resolve the key spectral identifiers of molecular structure that are critical to NMR applications in chemistry, structural biology and materials research, such as scalar couplings (which require a resolution of less than ten hertz) and small chemical shifts (which require a resolution of around one part per million of the nuclear Larmor frequency). Conventional, inductively detected NMR can provide the necessary high spectral resolution, but its limited sensitivity typically requires millimetre-scale samples, precluding applications that involve smaller samples, such as picolitre-volume chemical analysis or correlated optical and NMR microscopy. Here we demonstrate a measurement technique that uses a solid-state spin sensor (a magnetometer) consisting of an ensemble of nitrogen–vacancy centres in combination with a narrowband synchronized readout protocol to obtain NMR spectral resolution of about one hertz. We use this technique to observe NMR scalar couplings in a micrometre-scale sample volume of approximately ten picolitres. We also use the ensemble of nitrogen–vacancy centres to apply NMR to thermally polarized nuclear spins and resolve chemical-shift spectra from small molecules. Our technique enables analytical NMR spectroscopy at the scale of single cells.
ten Kate, Gerrit L.; Sijbrands, Eric J. G.; Valkema, Roelf; ten Cate, Folkert J.; Feinstein, Steven B.; van der Steen, Antonius F. W.; Daemen, Mat J. A. P.
2010-01-01
Current developments in cardiovascular biology and imaging enable the noninvasive molecular evaluation of atherosclerotic vascular disease. Intraplaque neovascularization sprouting from the adventitial vasa vasorum has been identified as an independent predictor of intraplaque hemorrhage and plaque rupture. These intraplaque vasa vasorum result from angiogenesis, most likely under influence of hypoxic and inflammatory stimuli. Several molecular imaging techniques are currently available. Most experience has been obtained with molecular imaging using positron emission tomography and single photon emission computed tomography. Recently, the development of targeted contrast agents has allowed molecular imaging with magnetic resonance imaging, ultrasound and computed tomography. The present review discusses the use of these molecular imaging techniques to identify inflammation and intraplaque vasa vasorum to identify vulnerable atherosclerotic plaques at risk of rupture and thrombosis. The available literature on molecular imaging techniques and molecular targets associated with inflammation and angiogenesis is discussed, and the clinical applications of molecular cardiovascular imaging and the use of molecular techniques for local drug delivery are addressed. PMID:20552308
Rossi, Esther; Bizzarro, Tommaso; Martini, Maurizio; Longatto-Filho, Adhemar; Schmitt, Fernando; Fagotti, Anna; Scambia, Giovanni; Zannoni, Gian Franco
2017-01-01
The cytological analysis of peritoneal effusions serves as a diagnostic and prognostic aid for either primary or metastatic diseases. Among the different cytological preparations, liquid based cytology (LBC) represents a feasible and reliable method ensuring also the application of ancillary techniques (i.e immunocytochemistry-ICC and molecular testing). We recorded 10348 LBC peritoneal effusions between January 2000 and December 2014. They were classified as non-diagnostic (ND), negative for malignancy-NM, atypical-suspicious for malignancy-SM and positive for malignancy-PM. The cytological diagnosis included 218 ND, 9.035 NM, 213 SM and 882 PM. A total of 8048 (7228 NM, 115SM, 705 PM) cases with histological follow-up were included. Our NM included 21 malignant and 7207 benign histological diagnoses. Our 820 SMs+PMs were diagnosed as 107 unknown malignancies (30SM and 77PM), 691 metastatic lesions (81SM and 610PM), 9 lymphomas (2SM and 7PM), 9 mesotheliomas (1SM and 8SM), 4 sarcomas (1SM and 3PM). Primary gynecological cancers contributed with 64% of the cases. We documented 97.4% sensitivity, 99.9% specificity, 98% diagnostic accuracy, 99.7% negative predictive value (NPV) and 99.7% positive predictive value (PPV). Furthermore, the morphological diagnoses were supported by either 173 conclusive ICC results or 50 molecular analyses. Specifically the molecular testing was performed for the EGFR and KRAS mutational analysis based on the previous or contemporary diagnoses of Non Small Cell Lung Cancer (NSCLC) and colon carcinomas. We identified 10 EGFR in NSCCL and 7 KRAS mutations on LBC stored material. Peritoneal cytology is an adjunctive tool in the surgical management of tumors mostly gynecological cancers. LBC maximizes the application of ancillary techniques such as ICC and molecular analysis with feasible diagnostic and predictive yields also in controversial cases.
Rossi, Esther; Bizzarro, Tommaso; Martini, Maurizio; Longatto-Filho, Adhemar; Schmitt, Fernando; Fagotti, Anna; Scambia, Giovanni; Zannoni, Gian Franco
2017-01-01
Background The cytological analysis of peritoneal effusions serves as a diagnostic and prognostic aid for either primary or metastatic diseases. Among the different cytological preparations, liquid based cytology (LBC) represents a feasible and reliable method ensuring also the application of ancillary techniques (i.e immunocytochemistry-ICC and molecular testing). Methods We recorded 10348 LBC peritoneal effusions between January 2000 and December 2014. They were classified as non-diagnostic (ND), negative for malignancy-NM, atypical-suspicious for malignancy-SM and positive for malignancy-PM. Results The cytological diagnosis included 218 ND, 9.035 NM, 213 SM and 882 PM. A total of 8048 (7228 NM, 115SM, 705 PM) cases with histological follow-up were included. Our NM included 21 malignant and 7207 benign histological diagnoses. Our 820 SMs+PMs were diagnosed as 107 unknown malignancies (30SM and 77PM), 691 metastatic lesions (81SM and 610PM), 9 lymphomas (2SM and 7PM), 9 mesotheliomas (1SM and 8SM), 4 sarcomas (1SM and 3PM). Primary gynecological cancers contributed with 64% of the cases. We documented 97.4% sensitivity, 99.9% specificity, 98% diagnostic accuracy, 99.7% negative predictive value (NPV) and 99.7% positive predictive value (PPV). Furthermore, the morphological diagnoses were supported by either 173 conclusive ICC results or 50 molecular analyses. Specifically the molecular testing was performed for the EGFR and KRAS mutational analysis based on the previous or contemporary diagnoses of Non Small Cell Lung Cancer (NSCLC) and colon carcinomas. We identified 10 EGFR in NSCCL and 7 KRAS mutations on LBC stored material. Conclusions Peritoneal cytology is an adjunctive tool in the surgical management of tumors mostly gynecological cancers. LBC maximizes the application of ancillary techniques such as ICC and molecular analysis with feasible diagnostic and predictive yields also in controversial cases. PMID:28099523
Exposure to low molecular weight (LMW) chemicals contributes to both dermal and respiratory sensitization and is an important occupational health problem. Our goal was to establish an in vivo murine model for hazard identification of LMW chemicals that have the potential to indu...
Sensitivities of ionic explosives
NASA Astrophysics Data System (ADS)
Politzer, Peter; Lane, Pat; Murray, Jane S.
2017-03-01
We have investigated the relevance for ionic explosive sensitivity of three factors that have been demonstrated to be related to the sensitivities of molecular explosives. These are (1) the maximum available heat of detonation, (2) the amount of free space per molecule (or per formula unit) in the crystal lattice and (3) specific features of the electrostatic potential on the molecular or ionic surface. We find that for ionic explosives, just as for molecular ones, there is an overall tendency for impact sensitivity to increase as the maximum detonation heat release is greater. This means that the usual emphasis upon designing explosives with large heats of detonation needs to be tempered somewhat. We also show that a moderate detonation heat release does not preclude a high level of detonation performance for ionic explosives, as was already demonstrated for molecular ones. Relating the free space per formula unit to sensitivity may require a modified procedure for ionic explosives; this will continue to be investigated. Finally, an encouraging start has been made in linking impact sensitivities to the electrostatic potentials on ionic surfaces, although limited so far to ammonium salts.
NASA Astrophysics Data System (ADS)
Liu, Chao-Fei; Juzeliūnas, Gediminas; Liu, W. M.
2017-02-01
Atomic-molecular Bose-Einstein condensates (BECs) offer brand new opportunities to revolutionize quantum gases and probe the variation of fundamental constants with unprecedented sensitivity. The recent realization of spin-orbit coupling (SOC) in BECs provides a new platform for exploring completely new phenomena unrealizable elsewhere. In this study, we find a way of creating a Rashba-Dresselhaus SOC in atomic-molecular BECs by combining the spin-dependent photoassociation and Raman coupling, which can control the formation and distribution of a different type of topological excitation—carbon-dioxide-like skyrmion. This skyrmion is formed by two half-skyrmions of molecular BECs coupling with one skyrmion of atomic BECs, where the two half-skyrmions locate at both sides of one skyrmion. Carbon-dioxide-like skyrmion can be detected by measuring the vortices structures using the time-of-flight absorption imaging technique in real experiments. Furthermore, we find that SOC can effectively change the occurrence of the Chern number in k space, which causes the creation of topological spin textures from some separated carbon-dioxide-like monomers each with topological charge -2 to a polymer chain of the skyrmions. This work helps in creating dual SOC atomic-molecular BECs and opens avenues to manipulate topological excitations.
Structure-activity relationships for serotonin transporter and dopamine receptor selectivity.
Agatonovic-Kustrin, Snezana; Davies, Paul; Turner, Joseph V
2009-05-01
Antipsychotic medications have a diverse pharmacology with affinity for serotonergic, dopaminergic, adrenergic, histaminergic and cholinergic receptors. Their clinical use now also includes the treatment of mood disorders, thought to be mediated by serotonergic receptor activity. The aim of our study was to characterise the molecular properties of antipsychotic agents, and to develop a model that would indicate molecular specificity for the dopamine (D(2)) receptor and the serotonin (5-HT) transporter. Back-propagation artificial neural networks (ANNs) were trained on a dataset of 47 ligands categorically assigned antidepressant or antipsychotic utility. The structure of each compound was encoded with 63 calculated molecular descriptors. ANN parameters including hidden neurons and input descriptors were optimised based on sensitivity analyses, with optimum models containing between four and 14 descriptors. Predicted binding preferences were in excellent agreement with clinical antipsychotic or antidepressant utility. Validated models were further tested by use of an external prediction set of five drugs with unknown mechanism of action. The SAR models developed revealed the importance of simple molecular characteristics for differential binding to the D(2) receptor and the 5-HT transporter. These included molecular size and shape, solubility parameters, hydrogen donating potential, electrostatic parameters, stereochemistry and presence of nitrogen. The developed models and techniques employed are expected to be useful in the rational design of future therapeutic agents.
Gallo, Erik; Gorelov, Evgeny; Guda, Alexander A; Bugaev, Aram L; Bonino, Francesca; Borfecchia, Elisa; Ricchiardi, Gabriele; Gianolio, Diego; Chavan, Sachin; Lamberti, Carlo
2017-12-04
We used Ni K-edge resonant-valence-to-core X-ray emission spectroscopy (RVtC-XES, also referred to as direct RIXS), an element-selective bulk-sensitive synchrotron-based technique, to investigate the electronic structure of the CPO-27-Ni metal-organic framework (MOF) upon molecular adsorption of significant molecular probes: H 2 O, CO, H 2 S, and NO. We compare RVtC-XES with UV-vis spectroscopy, and we show that the element selectivity of RVtC-XES is of strategic significance to observe the full set of d-d excitations in Ni 2+ , which are partially overshadowed by the low-energy π-π* transitions of the Ni ligands in standard diffuse-reflectance UV-vis experiments. Our combined RVtC-XES/UV-vis approach provides access to the whole set of d-d excitations, allowing us a complete discussion of the changes undergone by the electronic configuration of the Ni 2+ sites hosted within the MOF upon molecular adsorption. The experimental data have been interpreted by multiplet ligand-field theory calculations based on Wannier orbitals. This study represents a step further in understanding the ability of the CPO-27-Ni MOFs in molecular sorption and separation applications.
Takeno, Shinya; Bamba, Takeshi; Nakazawa, Yoshihisa; Fukusaki, Eiichiro; Okazawa, Atsushi; Kobayashi, Akio
2008-04-01
Commercial development of trans-1,4-polyisoprene from Eucommia ulmoides Oliver (EU-rubber) requires specific knowledge on selection of high-rubber-content lines and establishment of agronomic cultivation methods for achieving maximum EU-rubber yield. The development can be facilitated by high-throughput and highly sensitive analytical techniques for EU-rubber extraction and quantification. In this paper, we described an efficient EU-rubber extraction method, and validated that the accuracy was equivalent to that of the conventional Soxhlet extraction method. We also described a highly sensitive quantification method for EU-rubber by Fourier transform infrared spectroscopy (FT-IR) and pyrolysis-gas chromatography/mass spectrometry (PyGC/MS). We successfully applied the extraction/quantification method for study of seasonal changes in EU-rubber content and molecular weight distribution.
Plasmonic biosensor for label-free G-quadruplexes detection
NASA Astrophysics Data System (ADS)
Qiu, Suyan; Zhao, Fusheng; Santos, Greggy M.; Shih, Wei-Chuan
2016-03-01
G-quadruplex, readily formed by the G-rich sequence, potentially distributes in over 40 % of all human genes, such as the telomeric DNA with the G-rich sequence found at the end of the chromosome. The G-quadruplex structure is supposed to possess a diverse set of critical functions in the mammalian genome for transcriptional regulation, DNA replication and genome stability. However, most of the currently available methods for G-quadruplex identification are restricted to fluorescence techniques susceptible to poor sensitivity. It is essential to propose methods with higher sensitivity to specifically recognize the G-quadruplexes. In this study, we demonstrate a label-free plasmonic biosensor for G-quadruplex detection by relying on the advantages of nanoporous gold (NPG) disks that provide high-density plasmonic hot spots, suitable for molecular recognition capability without the requirement for labeling processes.
Resonant soft X-ray scattering for polymer materials
Liu, Feng; Brady, Michael A.; Wang, Cheng
2016-04-16
Resonant Soft X-ray Scattering (RSoXS) was developed within the last few years, and the first dedicated resonant soft X-ray scattering beamline for soft materials was constructed at the Advanced Light Source, LBNL. RSoXS combines soft X-ray spectroscopy with X-ray scattering and thus offers statistical information for 3D chemical morphology over a large length scale range from nanometers to micrometers. Using RSoXS to characterize multi-length scale soft materials with heterogeneous chemical structures, we have demonstrated that soft X-ray scattering is a unique complementary technique to conventional hard X-ray and neutron scattering. Its unique chemical sensitivity, large accessible size scale, molecular bondmore » orientation sensitivity with polarized X-rays, and high coherence have shown great potential for chemically specific structural characterization for many classes of materials.« less
Filip, Xenia; Borodi, Gheorghe; Filip, Claudiu
2011-10-28
A solid state structural investigation of ethoxzolamide is performed on microcrystalline powder by using a multi-technique approach that combines X-ray powder diffraction (XRPD) data analysis based on direct space methods with information from (13)C((15)N) solid-state Nuclear Magnetic Resonance (SS-NMR) and molecular modeling. Quantum chemical computations of the crystal were employed for geometry optimization and chemical shift calculations based on the Gauge Including Projector Augmented-Wave (GIPAW) method, whereas a systematic search in the conformational space was performed on the isolated molecule using a molecular mechanics (MM) approach. The applied methodology proved useful for: (i) removing ambiguities in the XRPD crystal structure determination process and further refining the derived structure solutions, and (ii) getting important insights into the relationship between the complex network of non-covalent interactions and the induced supra-molecular architectures/crystal packing patterns. It was found that ethoxzolamide provides an ideal case study for testing the accuracy with which this methodology allows to distinguish between various structural features emerging from the analysis of the powder diffraction data. This journal is © the Owner Societies 2011
Arab-Mazar, Zahra; Fallahi, Shirzad; Koochaki, Ameneh; Haghighi, Ali; Seyyed Tabaei, Seyyed Javad
2016-02-01
Serological assays for the diagnosis of toxoplasmosis mostly rely on the tachyzoite specific antigens of Toxoplasma gondii, which are difficult to produce by conventional methods. The aim of this study was to clone and express of GRA7 protein of T. gondii and evaluate its potential for immunodiagnosis of toxoplasmosis in cancer patients. As well as validate the results using a new molecular assay, LAMP technique. The GRA7 gene was successfully cloned, expressed and purified by affinity chromatography and the production was evaluated by SDS PAGE, dot blot and western blot analyses. The rGRA7 was used for developing an ELISA based on the rGRA7 using sera from patients with toxoplasmosis and healthy controls. Furthermore, 50 serum samples from leukemic children infected with toxoplasmosis and 50 seronegative controls were included to evaluate the sensitivity and specificity of rGRA7 based ELISA. Finally, the LAMP technique was used to assess the accuracy and validity of the results obtained by rGRA7 based ELISA. The consistency of the results of two tests was determined by using the Kappa coefficient of agreement. The rGRA7 showed higher and optimum immunoreactivity with 1:100 dilution of serum from Toxoplasma infected patients. The sensitivity and specificity of test were calculated as 92 and 94%, respectively. According to the Kappa coefficient of agreement, there was a significant conformance between the results obtained by ELISA based on the rGRA7 and the results of LAMP technique (≈96%, P<0.001). Findings of the present study showed that rGRA7 can be used as a potential immunogenic antigen for developing immunodiagnostic tools for immunodiagnosis of toxoplasmosis in patients including patients with cancer. Copyright © 2015. Published by Elsevier GmbH.
Karpf, Andreas; Qiao, Yuhao; Rao, Gottipaty N
2016-06-01
We present a simplified cavity ringdown (CRD) trace gas detection technique that is insensitive to vibration, and capable of extremely sensitive, real-time absorption measurements. A high-power, multimode Fabry-Perot (FP) diode laser with a broad wavelength range (Δλlaser∼0.6 nm) is used to excite a large number of cavity modes, thereby reducing the detector's susceptibility to vibration and making it well suited for field deployment. When detecting molecular species with broad absorption features (Δλabsorption≫Δλlaser), the laser's broad linewidth removes the need for precision wavelength stabilization. The laser's power and broad linewidth allow the use of on-axis cavity alignment, improving the signal-to-noise ratio while maintaining its vibration insensitivity. The use of an FP diode laser has the added advantages of being inexpensive, compact, and insensitive to vibration. The technique was demonstrated using a 1.1 W (λ=400 nm) diode laser to measure low concentrations of nitrogen dioxide (NO2) in zero air. A sensitivity of 38 parts in 1012 (ppt) was achieved using an integration time of 128 ms; for single-shot detection, 530 ppt sensitivity was demonstrated with a measurement time of 60 μs, which opens the door to sensitive measurements with extremely high temporal resolution; to the best of our knowledge, these are the highest speed measurements of NO2 concentration using CRD spectroscopy. The reduced susceptibility to vibration was demonstrated by introducing small vibrations into the apparatus and observing that there was no measurable effect on the sensitivity of detection.
Hess, Nancy J.; Pasa-Tolic, Ljiljana; Bailey, Vanessa L.; ...
2017-04-12
Understanding the role played by microorganisms within soil systems is challenged by the unique intersection of physics, chemistry, mineralogy and biology in fostering habitat for soil microbial communities. To address these challenges will require observations across multiple spatial and temporal scales to capture the dynamics and emergent behavior from complex and interdependent processes. The heterogeneity and complexity of the rhizosphere require advanced techniques that press the simultaneous frontiers of spatial resolution, analyte sensitivity and specificity, reproducibility, large dynamic range, and high throughput. Fortunately many exciting technical advancements are now available to inform and guide the development of new hypotheses. Themore » aim of this Special issue is to provide a holistic view of the rhizosphere in the perspective of modern molecular biology methodologies that enabled a highly-focused, detailed view on the processes in the rhizosphere, including numerous, strong and complex interactions between plant roots, soil constituents and microorganisms. We discuss the current rhizosphere research challenges and knowledge gaps, as well as perspectives and approaches using newly available state-of-the-art toolboxes. These new approaches and methodologies allow the study of rhizosphere processes and properties, and rhizosphere as a central component of ecosystems and biogeochemical cycles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hess, Nancy J.; Paša-Tolić, Ljiljana; Bailey, Vanessa L.
Understanding the role played by microorganisms within soil systems is challenged by the unique intersection of physics, chemistry, mineralogy and biology in fostering habitat for soil microbial communities. To address these challenges will require observations across multiple spatial and temporal scales to capture the dynamics and emergent behavior from complex and interdependent processes. The heterogeneity and complexity of the rhizosphere require advanced techniques that press the simultaneous frontiers of spatial resolution, analyte sensitivity and specificity, reproducibility, large dynamic range, and high throughput. Fortunately many exciting technical advancements are now available to inform and guide the development of new hypotheses. Themore » aim of this Special issue is to provide a holistic view of the rhizosphere in the perspective of modern molecular biology methodologies that enabled a highly-focused, detailed view on the processes in the rhizosphere, including numerous, strong and complex interactions between plant roots, soil constituents and microorganisms. We discuss the current rhizosphere research challenges and knowledge gaps, as well as perspectives and approaches using newly available state-of-the-art toolboxes. These new approaches and methodologies allow the study of rhizosphere processes and properties, and rhizosphere as a central component of ecosystems and biogeochemical cycles.« less
Kaczmarek, J; Jedryczka, M; Fitt, B D L; Lucas, J A; Latunde-Dada, A O
2009-01-01
Spores of many fungal pathogens are dispersed by wind. Detection of these airborne inocula is important in forecasting both the onset and the risk of epiphytotics. Species-specific primers targeted at the internal transcribed spacer (ITS) region of Leptosphaeria maculans and L. biglobosa - the causal organisms of phoma stem canker and stem lesions of Brassica spp., including oilseed rape - were used to detect DNA extracted from particles deposited on tapes obtained from a spore trap operated in Rarwino (northwest Poland) from September to November in 2004 and 2006. The quantities of DNA assessed by traditional end-point PCR and quantitative real-time PCR were compared to microscopic counts of airborne ascospores. Results of this study showed that fluctuations in timing of ascospore release corresponded to the dynamics of combined concentrations of DNA from L. maculans and L. biglobosa, with significant positive correlations between ascospore number and DNA yield. Thus the utilization of PCR-based molecular diagnostic techniques enabled the detection, identification, and accurate quantification of airborne inoculum at the species level. Moreover, real-time PCR was more sensitive than traditional PCR, especially in years with low ascospore numbers.
Coupling corona discharge for ambient extractive ionization mass spectrometry.
Hu, Bin; Zhang, Xinglei; Li, Ming; Peng, Xuejiao; Han, Jing; Yang, Shuiping; Ouyang, Yongzhong; Chen, Huanwen
2011-12-07
Unlike the extractive electrospray ionization (EESI) technique described elsewhere, a corona discharge instead of electrospray ionization has been utilized to charge a neutral solvent spray under ambient conditions for the generation of highly charged microdroplets, which impact a neutral sample plume for the extractive ionization of the analytes in raw samples without any sample pretreatment. Using the positive ion mode, molecular radical cations were easily generated for the detection of non-polar compounds (e.g., benzene, cyclohexane, etc.), while protonated molecular ions of polar compounds (e.g., acetonitrile, acetic ether) were readily produced for the detection. By dispensing the matrix in a relatively large space, this method tolerates highly complex matrices. For a given sample such as lily fragrances, more compounds were detected by the method established here than the EESI technique. An acceptable relative standard deviation (RSD 8.9%, n = 11) was obtained for the direct measurement of explosives (10 ppb) in waste water samples. The experimental data demonstrate that this method could simultaneously detect both polar and non-polar analytes with high sensitivity, showing promising applications for the rapid detection of a wide variety of compounds present in complex matrices.
Rapid non-enzymatic extraction method for isolating PCR-quality camelpox virus DNA from skin.
Yousif, A Ausama; Al-Naeem, A Abdelmohsen; Al-Ali, M Ahmad
2010-10-01
Molecular diagnostic investigations of orthopoxvirus (OPV) infections are performed using a variety of clinical samples including skin lesions, tissues from internal organs, blood and secretions. Skin samples are particularly convenient for rapid diagnosis and molecular epidemiological investigations of camelpox virus (CMLV). Classical extraction procedures and commercial spin-column-based kits are time consuming, relatively expensive, and require multiple extraction and purification steps in addition to proteinase K digestion. A rapid non-enzymatic procedure for extracting CMLV DNA from dried scabs or pox lesions was developed to overcome some of the limitations of the available DNA extraction techniques. The procedure requires as little as 10mg of tissue and produces highly purified DNA [OD(260)/OD(280) ratios between 1.47 and 1.79] with concentrations ranging from 6.5 to 16 microg/ml. The extracted CMLV DNA was proven suitable for virus-specific qualitative and, semi-quantitative PCR applications. Compared to spin-column and conventional viral DNA extraction techniques, the two-step extraction procedure saves money and time, and retains the potential for automation without compromising CMLV PCR sensitivity. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Chourasia, Mehul Kumar; Raghavendra, Kamaraju; Bhatt, Rajendra M; Swain, Dipak Kumar; Meshram, Hemraj M; Meshram, Jayant K; Suman, Shrity; Dubey, Vinita; Singh, Gyanendra; Prasad, Kona Madhavinadha; Kleinschmidt, Immo
2017-08-08
The burden of sub-patent malaria is difficult to recognize in low endemic areas due to limitation of diagnostic tools, and techniques. Polymerase chain reaction (PCR), a molecular based technique, is one of the key methods for detection of low parasite density infections. The study objective was to assess the additional burden of asymptomatic and sub-patent malaria infection among tribal populations inhabiting three endemic villages in Keshkal sub-district, Chhattisgarh, India. A cross-sectional survey was conducted in March-June 2016, during the low transmission season, to measure and compare prevalence of malaria infection using three diagnostics: rapid diagnostic test, microscopy and nested-PCR. Out of 437 individuals enrolled in the study, 103 (23.6%) were malaria positive by PCR and/or microscopy of whom 89.3% were Plasmodium falciparum cases, 77.7% were afebrile and 35.9% had sub-patent infections. A substantial number of asymptomatic and sub-patent malaria infections were identified in the survey. Hence, strategies for identifying and reducing the hidden burden of asymptomatic and sub-patent infections should focus on forest rural tribal areas using more sensitive molecular diagnostic methods to curtail malaria transmission.
Application of advanced cytometric and molecular technologies to minimal residual disease monitoring
NASA Astrophysics Data System (ADS)
Leary, James F.; He, Feng; Reece, Lisa M.
2000-04-01
Minimal residual disease monitoring presents a number of theoretical and practical challenges. Recently it has been possible to meet some of these challenges by combining a number of new advanced biotechnologies. To monitor the number of residual tumor cells requires complex cocktails of molecular probes that collectively provide sensitivities of detection on the order of one residual tumor cell per million total cells. Ultra-high-speed, multi parameter flow cytometry is capable of analyzing cells at rates in excess of 100,000 cells/sec. Residual tumor selection marker cocktails can be optimized by use of receiver operating characteristic analysis. New data minimizing techniques when combined with multi variate statistical or neural network classifications of tumor cells can more accurately predict residual tumor cell frequencies. The combination of these techniques can, under at least some circumstances, detect frequencies of tumor cells as low as one cell in a million with an accuracy of over 98 percent correct classification. Detection of mutations in tumor suppressor genes requires insolation of these rare tumor cells and single-cell DNA sequencing. Rare residual tumor cells can be isolated at single cell level by high-resolution single-cell cell sorting. Molecular characterization of tumor suppressor gene mutations can be accomplished using a combination of single- cell polymerase chain reaction amplification of specific gene sequences followed by TA cloning techniques and DNA sequencing. Mutations as small as a single base pair in a tumor suppressor gene of a single sorted tumor cell have been detected using these methods. Using new amplification procedures and DNA micro arrays it should be possible to extend the capabilities shown in this paper to screening of multiple DNA mutations in tumor suppressor and other genes on small numbers of sorted metastatic tumor cells.
Rossi, Esther Diana; Bizzarro, Tommaso; Schmitt, Fernando; Longatto-Filho, Adhemar
2015-04-01
Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility. © 2015 American Cancer Society.
Cost-effectiveness study of the microbiological diagnosis of tuberculosis using geneXpert MTB/RIF®.
Herráez, Óscar; Asencio-Egea, María Ángeles; Huertas-Vaquero, María; Carranza-González, Rafael; Castellanos-Monedero, Jesús; Franco-Huerta, María; Barberá-Farré, José Ramón; Tenías-Burillo, José María
To perform a cost-effectiveness analysis of a molecular biology technique for the diagnosis of tuberculosis compared to the classical diagnostic alternative. A cost-effectiveness analysis was performed to evaluate the theoretical implementation of a molecular biology method including two alternative techniques for early detection of Mycobacterium tuberculosis Complex, and resistance to rifampicin (alternative1: one determination in selected patients; alternative2: two determinations in all the patients). Both alternatives were compared with the usual procedure for microbiological diagnosis of tuberculosis (staining and microbiological culture), and was accomplished on 1,972 patients in the period in 2008-2012. The effectiveness was measured in QALYs, and the uncertainty was assessed by univariate, multivariate and probabilistic analysis of sensitivity. A value of €8,588/QALYs was obtained by the usual method. Total expenditure with the alternative1 was €8,487/QALYs, whereas with alternative2, the cost-effectiveness ratio amounted to €2,960/QALYs. Greater diagnostic efficiency was observed by applying the alternative2, reaching a 75% reduction in the number of days that a patient with tuberculosis remains without an adequate treatment, and a 70% reduction in the number of days that a patient without tuberculosis remains in hospital. The implementation of a molecular microbiological technique in the diagnosis of tuberculosis is extremely cost-effective compared to the usual method. Its introduction into the routine diagnostic procedure could lead to an improvement in quality care for patients, given that it would avoid both unnecessary hospitalisations and treatments, and reflected in economic savings to the hospital. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
NASA Astrophysics Data System (ADS)
Digman, Michelle
Fluorescence fluctuation spectroscopy has evolved from single point detection of molecular diffusion to a family of microscopy imaging correlation tools (i.e. ICS, RICS, STICS, and kICS) useful in deriving spatial-temporal dynamics of proteins in living cells The advantage of the imaging techniques is the simultaneous measurement of all points in an image with a frame rate that is increasingly becoming faster with better sensitivity cameras and new microscopy modalities such as the sheet illumination technique. A new frontier in this area is now emerging towards a high level of mapping diffusion rates and protein dynamics in the 2 and 3 dimensions. In this talk, I will discuss the evolution of fluctuation analysis from the single point source to mapping diffusion in whole cells and the technology behind this technique. In particular, new methods of analysis exploit correlation of molecular fluctuations originating from measurement of fluctuation correlations at distant points (pair correlation analysis) and methods that exploit spatial averaging of fluctuations in small regions (iMSD). For example the pair correlation fluctuation (pCF) analyses done between adjacent pixels in all possible radial directions provide a window into anisotropic molecular diffusion. Similar to the connectivity atlas of neuronal connections from the MRI diffusion tensor imaging these new tools will be used to map the connectome of protein diffusion in living cells. For biological reaction-diffusion systems, live single cell spatial-temporal analysis of protein dynamics provides a mean to observe stochastic biochemical signaling in the context of the intracellular environment which may lead to better understanding of cancer cell invasion, stem cell differentiation and other fundamental biological processes. National Institutes of Health Grant P41-RRO3155.
NASA Astrophysics Data System (ADS)
Zhang, Weiying; Lou, Inchio; Ung, Wai Kin; Kong, Yijun; Mok, Kai Meng
2014-06-01
Freshwater algal blooms have become a growing concern world-wide. They are caused by a high level of cyanobacteria, predominantly Microcystis spp. and Cylindrospermopsis raciborskii, which can produce microcystin and cylindrospermopsin, respectively. Longtime exposure to these cyanotoxins may affect public health, thus reliable detection, quantification, and enumeration of these harmful algae species has become a priority in water quality management. Traditional manual enumeration of algal bloom cells primarily involves microscopic identification which limited by inaccuracy and time-consumption.With the development of molecular techniques and an increasing number of microbial sequences available in the Genbank database, the use of molecular methods can be used for more rapid, reliable, and accurate detection and quantification. In this study, multiplex polymerase chain reaction (PCR) and real-time quantitative PCR (qPCR) techniques were developed and applied for monitoring cyanobacteria Microcystis spp. and C. raciborskii in the Macau Storage Reservoir (MSR). The results showed that the techniques were successful for identifying and quantifying the species in pure cultures and mixed cultures, and proved to be a potential application for water sampling in MSR. When the target species were above 1 million cells/L, similar cell numbers estimated by microscopic enumeration and qPCR were obtained. Further quantification in water samples indicated that the ratio of the estimated number of cell by microscopy and qPCR was 0.4-12.9 for cyanobacteria and 0.2-3.9 for C. raciborskii. However, Microcystis spp. was not observed by manual enumeration, while it was detected at low levels by qPCR, suggesting that qPCR is more sensitive and accurate. Thus the molecular approaches provide an additional reliable monitoring option to traditional microscopic enumeration for the ecosystems monitoring program.
Torsional tapping atomic force microscopy for molecular resolution imaging of soft matter
NASA Astrophysics Data System (ADS)
Hobbs, Jamie; Mullin, Nic
2012-02-01
Despite considerable advances in image resolution on challenging, soft systems, a method for obtaining molecular resolution on `real' samples with significant surface roughness has remained elusive. Here we will show that a relatively new technique, torsional tapping AFM (TTAFM), is capable of imaging with resolution down to 3.7 Angrstrom on the surface of `bulk' polymer films [1]. In TTAFM T-shaped cantilevers are driven into torsional oscillation. As the tip is offset from the rotation axis this provides a tapping motion. Due to the high frequency and Q of the oscillation and relatively small increase in spring constant, improved cantilever dynamics and force sensitivity are obtained. As the tip offset from the torsional axis is relatively small (typically 25 microns), the optical lever sensitivity is considerably improved compared to flexural oscillation. Combined these give a reduction in noise floor by a factor of 12 just by changing the cantilever geometry. The ensuing low noise allows the use of ultra-sharp `whisker' tips with minimal blunting. As the cantilevers remain soft in the flexural axis, the force when imaging with error is also reduced, further protecting the tip. We will show that this combination allows routine imaging of the molecular structure of semicrystalline polymer films, including chain folds, loose loops and tie-chains in polyethylene, and the helical conformation of polypropylene within the crystal, using a standard, commercial AFM. [4pt] [1] N Mullin, JK Hobbs, PRL 107, 197801 (2011)
ToF-SIMS and Laser-SNMS Imaging of Heterogeneous Topographically Complex Polymer Systems.
Pelster, Andreas; Körsgen, Martin; Kurosawa, Takako; Morita, Hiromi; Arlinghaus, Heinrich F
2016-10-04
Heterogeneous polymer coatings, such as those used in organic electronics and medical devices, are of increasing industrial importance. In order to advance the development of these types of systems, analytical techniques are required which are able to determine the elemental and molecular spatial distributions, on a nanometer scale, with very high detection efficiency and sensitivity. The goal of this study was to investigate the suitability of laser postionization secondary neutral mass spectrometry (Laser-SNMS) with a 157 nm postionization laser beam to image structured polymer mixtures and compare the results with time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements using Bi 3 + primary ions. The results showed that Laser-SNMS is better suited than ToF-SIMS for unambiguous detection and submicrometer imaging of the wide range of polymers investigated. The data also showed that Laser-SNMS has the advantage of being much more sensitive (in general higher by more than an order of magnitude and peaking at up to 3 orders of magnitude) than ToF-SIMS while also showing superior performance on topographically complex structured insulating surfaces, due to significantly reduced field effects and a higher dynamic range as compared to ToF-SIMS. It is concluded that Laser-SNMS is a powerful complementary technique to ToF-SIMS for the analysis of heterogeneous polymers and other complex structured organic mixtures, providing submicrometer resolution and high sensitivity.
NASA Technical Reports Server (NTRS)
Morten, F. D. (Editor); Seeley, John S. (Editor)
1986-01-01
The present conference on advancements in IR-sensitive materials and detector technologies employing them gives attention to thermal detectors, focal plane array processing detectors, novel detector designs, general properties of IR optics materials, and preparation methods for such materials. Specific topics encompass the fabrication of InSb MIS structures prepared by photochemical vapor deposition, IR heterodyne detectors employing cadmium mercury telluride, low microphony pyroelectric arrays, IR detection based on minority carrier extrusion, longwave reststrahl in IR crystals, and molecular beam techniques for optical thin film fabrication.
Molecularly imprinted polymer sensors for detection in the gas, liquid, and vapor phase.
Jenkins, Amanda L; Ellzy, Michael W; Buettner, Leonard C
2012-06-01
Fast, reliable, and inexpensive analytical techniques for detection of airborne chemical warfare agents are desperately needed. Recent advances in the field of molecularly imprinted polymers have created synthetic nanomaterials that can sensitively and selectively detect these materials in aqueous environments, but thus far, they have not been demonstrated to work for detection of vapors. The imprinted polymers function by mimicking the function of biological receptors. They can provide high sensitivity and selectivity but, unlike their biological counterparts, maintain excellent thermal and mechanical stability. The traditional imprinted polymer approach is further enhanced in this work by the addition of a luminescent europium that has been introduced into the polymers to provide enhanced chemical affinity as well as a method for signal transduction to indicate the binding event. The europium in these polymers is so sensitive to the bound target; it can distinguish between species differing by a single methyl group. The imprinted polymer technology is fiber optic-based making it inexpensive and easily integratable with commercially available miniature fiber optic spectrometer technologies to provide a shoebox size device. In this work, we will describe efforts to apply these sensors for detection of airborne materials and vapors. Successful application of this technology will provide accurate low level vapor detection of chemical agents or pesticides with little to no false positives. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.
Bioanalytical applications of SERS (surface-enhanced Raman spectroscopy).
Hudson, Stephen D; Chumanov, George
2009-06-01
Surface-enhanced Raman scattering (SERS) is a powerful technique for analyzing biological samples as it can rapidly and nondestructively provide chemical and, in some cases, structural information about molecules in aqueous environments. In the Raman scattering process, both visible and near-infrared (NIR) wavelengths of light can be used to induce polarization of Raman-active molecules, leading to inelastic light scattering that yields specific molecular vibrational information. The development of surface enhancement has enabled Raman scattering to be an effective tool for qualitative as well as quantitative measurements with high sensitivity and specificity. Recent advances have led to many novel applications of SERS for biological analyses, resulting in new insights for biochemistry and molecular biology, the detection of biological warfare agents, and medical diagnostics for cancer, diabetes, and other diseases. This trend article highlights many of these recent investigations and provides a brief outlook in order to assess possible future directions of SERS as a bioanalytical tool.
Polymerase chain reaction: A molecular diagnostic tool in periodontology
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease. PMID:27143822
Intravascular Optical Imaging Technology for Investigating the Coronary Artery
Suter, Melissa J.; Nadkarni, Seemantini K.; Weisz, Giora; Tanaka, Atsushi; Jaffer, Farouc A.; Bouma, Brett E.; Tearney, Guillermo J.
2012-01-01
There is an ever-increasing demand for new imaging methods that can provide additional information about the coronary wall to better characterize and stratify high-risk plaques, and to guide interventional and pharmacologic management of patients with coronary artery disease. While there are a number of imaging modalities that facilitate the assessment of coronary artery pathology, this review paper focuses on intravascular optical imaging modalities that provide information on the microstructural, compositional, biochemical, biomechanical, and molecular features of coronary lesions and stents. The optical imaging modalities discussed include angioscopy, optical coherence tomography, polarization sensitive-optical coherence tomography, laser speckle imaging, near-infrared spectroscopy, time-resolved laser induced fluorescence spectroscopy, Raman spectroscopy, and near-infrared fluorescence molecular imaging. Given the wealth of information that these techniques can provide, optical imaging modalities are poised to play an increasingly significant role in the evaluation of the coronary artery in the future. PMID:21920342
Imaging Live Drosophila Brain with Two-Photon Fluorescence Microscopy
NASA Astrophysics Data System (ADS)
Ahmed, Syeed Ehsan
Two-photon fluorescence microscopy is an imaging technique which delivers distinct benefits for in vivo cellular and molecular imaging. Cyclic adenosine monophosphate (cAMP), a second messenger molecule, is responsible for triggering many physiological changes in neural system. However, the mechanism by which this molecule regulates responses in neuron cells is not yet clearly understood. When cAMP binds to a target protein, it changes the structure of that protein. Therefore, studying this molecular structure change with fluorescence resonance energy transfer (FRET) imaging can shed light on the cAMP functioning mechanism. FRET is a non-radiative dipole-dipole coupling which is sensitive to small distance change in nanometer scale. In this study we have investigated the effect of dopamine in cAMP dynamics in vivo. In our study two-photon fluorescence microscope was used for imaging mushroom bodies inside live Drosophila melanogaster brain and we developed a method for studying the change in cyclic AMP level.
Michaelsen, Astrid; Piñar, Guadalupe
2010-01-01
This case study shows the application of nontraditional diagnostic methods to investigate the microbial consortia inhabiting an ancient manuscript. The manuscript was suspected to be biologically deteriorated and SEM observations showed the presence of fungal spores attached to fibers, but classic culturing methods did not succeed in isolating microbial contaminants. Therefore, molecular methods, including PCR, denaturing gradient gel electrophoresis (DGGE), and clone libraries, were used as a sensitive alternative to conventional cultivation techniques. DGGE fingerprints revealed a high biodiversity of both bacteria and fungi inhabiting the manuscript. DNA sequence analysis confirmed the existence of fungi and bacteria in manuscript samples. A number of fungal clones identified on the manuscript showed similarity to fungal species inhabiting dry or saline environments, suggesting that the manuscript environment selects for osmophilic or xerophilic fungal species. Most of the bacterial sequences retrieved from the manuscript belong to phylotypes with cellulolytic activities. PMID:20449583
Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applications
Sosnovik, David E.; Nahrendorf, Matthias; Weissleder, Ralph
2008-01-01
Magnetic nanoparticles (MNP) are playing an increasingly important role in cardiovascular molecular imaging. These agents are superparamagnetic and consist of a central core of iron-oxide surrounded by a carbohydrate or polymer coat. The size, physical properties and pharmacokinetics of MNP make them highly suited to cellular and molecular imaging of atherosclerotic plaque and myocardial injury. MNP have a sensitivity in the nanomolar range and can be detected with T1, T2, T2*, off resonance and steady state free precession sequences. Targeted imaging with MNP is being actively explored and can be achieved through either surface modification or through the attachment of an affinity ligand to the nanoparticle. First generation MNP are already in clinical use and second generation agents, with longer blood half lives, are likely to be approved for routine clinical use in the near future. PMID:18324368
Jensen, Malene Ringkjøbing; Markwick, Phineus R L; Meier, Sebastian; Griesinger, Christian; Zweckstetter, Markus; Grzesiek, Stephan; Bernadó, Pau; Blackledge, Martin
2009-09-09
Intrinsically disordered proteins (IDPs) inhabit a conformational landscape that is too complex to be described by classical structural biology, posing an entirely new set of questions concerning the molecular understanding of functional biology. The characterization of the conformational properties of IDPs, and the elucidation of the role they play in molecular function, is therefore one of the major challenges remaining for modern structural biology. NMR is the technique of choice for studying this class of proteins, providing information about structure, flexibility, and interactions at atomic resolution even in completely disordered states. In particular, residual dipolar couplings (RDCs) have been shown to be uniquely sensitive and powerful tools for characterizing local and long-range structural behavior in disordered proteins. In this review we describe recent applications of RDCs to quantitatively describe the level of local structure and transient long-range order in IDPs involved in viral replication, neurodegenerative disease, and cancer.
NASA Astrophysics Data System (ADS)
Vaknin, D.; Garlea, V. O.; Demmel, F.; Mamontov, E.; Nojiri, H.; Martin, C.; Chiorescu, I.; Qiu, Y.; Kögerler, P.; Fielden, J.; Engelhardt, L.; Rainey, C.; Luban, M.
2010-11-01
Inelastic neutron scattering (INS) in variable magnetic field and high-field magnetization measurements in the millikelvin temperature range were performed to gain insight into the low-energy magnetic excitation spectrum and the field-induced level crossings in the molecular spin cluster {Cr8}-cubane. These complementary techniques provide consistent estimates of the lowest level-crossing field. The overall features of the experimental data are explained using an isotropic Heisenberg model, based on three distinct exchange interactions linking the eight CrIII paramagnetic centers (spins s = 3/2), that is supplemented with a relatively large molecular magnetic anisotropy term for the lowest S = 1 multiplet. It is noted that the existence of the anisotropy is clearly evident from the magnetic field dependence of the excitations in the INS measurements, while the magnetization measurements are not sensitive to its effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaknin, D.; Garlea, Vasile O; Demmel, F.
Inelastic neutron scattering (INS) in variable magnetic field and high-field magnetization measurements in the millikelvin temperature range were performed to gain insight into the low-energy magnetic excitation spectrum and the field-induced level crossings in the molecular spin cluster {Cr8}-cubane. These complementary techniques provide consistent estimates of the lowest level-crossing field. The overall features of the experimental data are explained using an isotropic Heisenberg model, based on three distinct exchange interactions linking the eight CrIII paramagnetic centers (spins s = 3/2), that is supplemented with a relatively large molecular magnetic anisotropy term for the lowest S = 1 multiplet. It ismore » noted that the existence of the anisotropy is clearly evident from the magnetic field dependence of the excitations in the INS measurements, while the magnetization measurements are not sensitive to its effects.« less
Cutaneous Amebiasis: The Importance of Molecular Diagnosis of an Emerging Parasitic Disease
Morán, Patricia; Rojas, Liliana; Cerritos, René; Zermeño, Valeria; Valadez, Alicia; de Oca, Griselda Montes; Reyes, Miguel Ángel; González, Enrique; Partida, Oswaldo; Hernández, Eric; Nieves, Miriam; Portillo, Tobías; Gudiño, Marco; Ramiro, Manuel; Ximénez, Cecilia
2013-01-01
Cutaneous amebiasis is the least common clinical form of human amebiasis in Mexico, sexual amebiasis was only occasionally observed before the late 1980s. However, in the last few decades, most of the documented cases of cutaneous amebiasis from around the world are sexually transmitted. We present two cases of sexually transmitted genital amebiasis. The molecular characterization of the Entamoeba species in the affected tissues underlines the importance of an etiological diagnosis using specific and sensitive techniques that avoid the rapid destruction of tissues and the irreversible sequelae to the anatomy and function of the affected organs. In addition, for those interested in the study of the human-amoebic disease relationship and its epidemiology, the detection of a new, mixed infection in an invasive case of amebiasis reveals new perspectives in the study of the extraordinarily complex host-parasite relationship in amebiasis. PMID:23208883
Polymerase chain reaction: A molecular diagnostic tool in periodontology.
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease.
Molecular diagnostics for the detection and characterization of microbial pathogens.
Procop, Gary W
2007-09-01
New and advanced methods of molecular diagnostics are changing the way we practice clinical microbiology, which affects the practice of medicine. Signal amplification and real-time nucleic acid amplification technologies offer a sensitive and specific result with a more rapid turnaround time than has ever before been possible. Numerous methods of postamplification analysis afford the simultaneous detection and differentiation of numerous microbial pathogens, their mechanisms of resistance, and the construction of disease-specific assays. The technical feasibility of these assays has already been demonstrated. How these new, often more expensive tests will be incorporated into routine practice and the impact they will have on patient care remain to be determined. One of the most attractive uses for such techniques is to achieve a more rapid characterization of the infectious agent so that a narrower-spectrum antimicrobial agent may be used, which should have an impact on resistance patterns.
Molecular Modeling of Thermodynamic and Transport Properties for CO 2 and Aqueous Brines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Hao; Economou, Ioannis G.; Panagiotopoulos, Athanassios Z.
Molecular simulation techniques using classical force-fields occupy the space between ab initio quantum mechanical methods and phenomenological correlations. In particular, Monte Carlo and molecular dynamics algorithms can be used to provide quantitative predictions of thermodynamic and transport properties of fluids relevant for geologic carbon sequestration at conditions for which experimental data are uncertain or not available. These methods can cover time and length scales far exceeding those of quantum chemical methods, while maintaining transferability and predictive power lacking from phenomenological correlations. The accuracy of predictions depends sensitively on the quality of the molecular models used. Many existing fixed-point-charge models formore » water and aqueous mixtures fail to represent accurately these fluid properties, especially when descriptions covering broad ranges of thermodynamic conditions are needed. Recent work on development of accurate models for water, CO 2, and dissolved salts, as well as their mixtures, is summarized in this Account. Polarizable models that can respond to the different dielectric environments in aqueous versus nonaqueous phases are necessary for predictions of properties over extended ranges of temperatures and pressures. Phase compositions and densities, activity coefficients of the dissolved salts, interfacial tensions, viscosities and diffusivities can be obtained in near-quantitative agreement to available experimental data, using relatively modest computational resources. In some cases, for example, for the composition of the CO 2-rich phase in coexistence with an aqueous phase, recent results from molecular simulations have helped discriminate among conflicting experimental data sets. The sensitivity of properties on the quality of the intermolecular interaction model varies significantly. Properties such as the phase compositions or electrolyte activity coefficients are much more sensitive than phase densities, viscosities, or component diffusivities. Strong confinement effects on physical properties in nanoscale media can also be directly obtained from molecular simulations. Future work on molecular modeling for CO 2 and aqueous brines is likely to be focused on more systematic generation of interaction models by utilizing quantum chemical as well as direct experimental measurements. New ion models need to be developed for use with the current generation of polarizable water models, including ion–ion interactions that will allow for accurate description of dense, mixed brines. Methods will need to be devised that go beyond the use of effective potentials for incorporation of quantum effects known to be important for water, and reactive force fields developed that can handle bond creation and breaking in systems with carbonate and silicate minerals. Lastly, another area of potential future work is the integration of molecular simulation methods in multiscale models for the chemical reactions leading to mineral dissolution and flow within the porous media in underground formations.« less
Molecular Modeling of Thermodynamic and Transport Properties for CO2 and Aqueous Brines.
Jiang, Hao; Economou, Ioannis G; Panagiotopoulos, Athanassios Z
2017-04-18
Molecular simulation techniques using classical force-fields occupy the space between ab initio quantum mechanical methods and phenomenological correlations. In particular, Monte Carlo and molecular dynamics algorithms can be used to provide quantitative predictions of thermodynamic and transport properties of fluids relevant for geologic carbon sequestration at conditions for which experimental data are uncertain or not available. These methods can cover time and length scales far exceeding those of quantum chemical methods, while maintaining transferability and predictive power lacking from phenomenological correlations. The accuracy of predictions depends sensitively on the quality of the molecular models used. Many existing fixed-point-charge models for water and aqueous mixtures fail to represent accurately these fluid properties, especially when descriptions covering broad ranges of thermodynamic conditions are needed. Recent work on development of accurate models for water, CO 2 , and dissolved salts, as well as their mixtures, is summarized in this Account. Polarizable models that can respond to the different dielectric environments in aqueous versus nonaqueous phases are necessary for predictions of properties over extended ranges of temperatures and pressures. Phase compositions and densities, activity coefficients of the dissolved salts, interfacial tensions, viscosities and diffusivities can be obtained in near-quantitative agreement to available experimental data, using relatively modest computational resources. In some cases, for example, for the composition of the CO 2 -rich phase in coexistence with an aqueous phase, recent results from molecular simulations have helped discriminate among conflicting experimental data sets. The sensitivity of properties on the quality of the intermolecular interaction model varies significantly. Properties such as the phase compositions or electrolyte activity coefficients are much more sensitive than phase densities, viscosities, or component diffusivities. Strong confinement effects on physical properties in nanoscale media can also be directly obtained from molecular simulations. Future work on molecular modeling for CO 2 and aqueous brines is likely to be focused on more systematic generation of interaction models by utilizing quantum chemical as well as direct experimental measurements. New ion models need to be developed for use with the current generation of polarizable water models, including ion-ion interactions that will allow for accurate description of dense, mixed brines. Methods will need to be devised that go beyond the use of effective potentials for incorporation of quantum effects known to be important for water, and reactive force fields developed that can handle bond creation and breaking in systems with carbonate and silicate minerals. Another area of potential future work is the integration of molecular simulation methods in multiscale models for the chemical reactions leading to mineral dissolution and flow within the porous media in underground formations.
Molecular Modeling of Thermodynamic and Transport Properties for CO 2 and Aqueous Brines
Jiang, Hao; Economou, Ioannis G.; Panagiotopoulos, Athanassios Z.
2017-02-24
Molecular simulation techniques using classical force-fields occupy the space between ab initio quantum mechanical methods and phenomenological correlations. In particular, Monte Carlo and molecular dynamics algorithms can be used to provide quantitative predictions of thermodynamic and transport properties of fluids relevant for geologic carbon sequestration at conditions for which experimental data are uncertain or not available. These methods can cover time and length scales far exceeding those of quantum chemical methods, while maintaining transferability and predictive power lacking from phenomenological correlations. The accuracy of predictions depends sensitively on the quality of the molecular models used. Many existing fixed-point-charge models formore » water and aqueous mixtures fail to represent accurately these fluid properties, especially when descriptions covering broad ranges of thermodynamic conditions are needed. Recent work on development of accurate models for water, CO 2, and dissolved salts, as well as their mixtures, is summarized in this Account. Polarizable models that can respond to the different dielectric environments in aqueous versus nonaqueous phases are necessary for predictions of properties over extended ranges of temperatures and pressures. Phase compositions and densities, activity coefficients of the dissolved salts, interfacial tensions, viscosities and diffusivities can be obtained in near-quantitative agreement to available experimental data, using relatively modest computational resources. In some cases, for example, for the composition of the CO 2-rich phase in coexistence with an aqueous phase, recent results from molecular simulations have helped discriminate among conflicting experimental data sets. The sensitivity of properties on the quality of the intermolecular interaction model varies significantly. Properties such as the phase compositions or electrolyte activity coefficients are much more sensitive than phase densities, viscosities, or component diffusivities. Strong confinement effects on physical properties in nanoscale media can also be directly obtained from molecular simulations. Future work on molecular modeling for CO 2 and aqueous brines is likely to be focused on more systematic generation of interaction models by utilizing quantum chemical as well as direct experimental measurements. New ion models need to be developed for use with the current generation of polarizable water models, including ion–ion interactions that will allow for accurate description of dense, mixed brines. Methods will need to be devised that go beyond the use of effective potentials for incorporation of quantum effects known to be important for water, and reactive force fields developed that can handle bond creation and breaking in systems with carbonate and silicate minerals. Lastly, another area of potential future work is the integration of molecular simulation methods in multiscale models for the chemical reactions leading to mineral dissolution and flow within the porous media in underground formations.« less
Empirical Observations on the Sensitivity of Hot Cathode Ionization Type Vacuum Gages
NASA Technical Reports Server (NTRS)
Summers, R. L.
1969-01-01
A study of empirical methods of predicting tile relative sensitivities of hot cathode ionization gages is presented. Using previously published gage sensitivities, several rules for predicting relative sensitivity are tested. The relative sensitivity to different gases is shown to be invariant with gage type, in the linear range of gage operation. The total ionization cross section, molecular and molar polarizability, and refractive index are demonstrated to be useful parameters for predicting relative gage sensitivity. Using data from the literature, the probable error of predictions of relative gage sensitivity based on these molecular properties is found to be about 10 percent. A comprehensive table of predicted relative sensitivities, based on empirical methods, is presented.
Evaluation of molecular dynamics simulation methods for ionic liquid electric double layers.
Haskins, Justin B; Lawson, John W
2016-05-14
We investigate how systematically increasing the accuracy of various molecular dynamics modeling techniques influences the structure and capacitance of ionic liquid electric double layers (EDLs). The techniques probed concern long-range electrostatic interactions, electrode charging (constant charge versus constant potential conditions), and electrolyte polarizability. Our simulations are performed on a quasi-two-dimensional, or slab-like, model capacitor, which is composed of a polarizable ionic liquid electrolyte, [EMIM][BF4], interfaced between two graphite electrodes. To ensure an accurate representation of EDL differential capacitance, we derive new fluctuation formulas that resolve the differential capacitance as a function of electrode charge or electrode potential. The magnitude of differential capacitance shows sensitivity to different long-range electrostatic summation techniques, while the shape of differential capacitance is affected by charging technique and the polarizability of the electrolyte. For long-range summation techniques, errors in magnitude can be mitigated by employing two-dimensional or corrected three dimensional electrostatic summations, which led to electric fields that conform to those of a classical electrostatic parallel plate capacitor. With respect to charging, the changes in shape are a result of ions in the Stern layer (i.e., ions at the electrode surface) having a higher electrostatic affinity to constant potential electrodes than to constant charge electrodes. For electrolyte polarizability, shape changes originate from induced dipoles that soften the interaction of Stern layer ions with the electrode. The softening is traced to ion correlations vertical to the electrode surface that induce dipoles that oppose double layer formation. In general, our analysis indicates an accuracy dependent differential capacitance profile that transitions from the characteristic camel shape with coarser representations to a more diffuse profile with finer representations.
Cao, Jing; Feng, Chao; Liu, Yan; Wang, Shouyu; Liu, Fei
2014-07-15
Since many diseases are caused by pathogenic bacterial infections, accurate and rapid detection of pathogenic bacteria is in urgent need to timely apply appropriate treatments and to reduce economic costs. To end this, we designed molecular beacon-Au nanoparticle hybrid nanoprobes to improve the bacterial detection efficiency and sensitivity. Here, we show that the designed molecular beacon modified Au nanoparticles could specifically recognize synthetic DNAs targets and can readily detect targets in clinical samples. Moreover, the hybrid nanoprobes can recognize Escherichia coli within an hour at a concentration of 10(2) cfu/ml, which is 1000-folds sensitive than using molecular beacon directly. Our results show that the molecular beacon-Au nanoparticle hybrid nanoprobes have great potential in medical and biological applications. Copyright © 2014 Elsevier B.V. All rights reserved.
[The use of molecular biology techniques in the articles published in Revista Médica de Chile].
Herskovic, V; Jacard, M; Reyes, H
2000-04-01
Molecular biology is a new branch of biological sciences, with novel laboratory techniques that are being progressively applied into biomedical and clinical research and, furthermore, into medical practice. To evaluate the use of molecular biology techniques in Chilean biomedical and clinical research and its evolution in the recent decade. All papers published as research articles, clinical experiences or case reports, in Revista Médica de Chile, during two time periods: 1987-1989 and 1997-1999, were reviewed to find out whether molecular biology techniques had been used or not. This journal publishes roughly 40% of papers generated in Chile, in biomedical or clinical topics, while another 15% appears in foreign journals. Among 341 papers published in 1987-1989, 57 (16.7%) had used one or more molecular biology techniques; in contrast, among 318 papers published in 1997-1999, 91 (28.8%) had used them (p < 0.001). Most papers using molecular biology techniques were research articles. Immunology, genetics, endocrinology, hematology, hepatology and rheumatology were the specialties providing a greater number and proportion of papers using molecular biology techniques. Chilean universities were the main institutions sponsoring these articles and FONDECYT (the Chilean Government Research Granting Office) was the main source of funding. The University of Chile (State-owned) provided most centers where these publications had been generated, followed by the Pontifical Catholic University of Chile. Molecular biology techniques have been rapidly and progressively incorporated as research tools in biomedicine and clinical medicine, in Chile. At the present time, these techniques are predominantly used in research conducted in University settings and funded by Governmental research grants.
NASA Astrophysics Data System (ADS)
Ghosh, S. B.; Bhattacharya, K.; Nayak, S.; Mukherjee, P.; Salaskar, D.; Kale, S. P.
2015-09-01
Definitive identification of microorganisms, including pathogenic and non-pathogenic bacteria, is extremely important for a wide variety of applications including food safety, environmental studies, bio-terrorism threats, microbial forensics, criminal investigations and above all disease diagnosis. Although extremely powerful techniques such as those based on PCR and microarrays exist, they require sophisticated laboratory facilities along with elaborate sample preparation by trained researchers. Among different spectroscopic techniques, FTIR was used in the 1980s and 90s for bacterial identification. In the present study five species of Bacillus were isolated from the aerobic predigester chamber of Nisargruna Biogas Plant (NBP) and were identified to the species level by biochemical and molecular biological (16S ribosomal DNA sequence) methods. Those organisms were further checked by solid state spectroscopic absorbance measurements using a wide range of electromagnetic radiation (wavelength 200 nm to 25,000 nm) encompassing UV, visible, near Infrared and Infrared regions. UV-Vis and NIR spectroscopy was performed on dried bacterial cell suspension on silicon wafer in specular mode while FTIR was performed on KBr pellets containing the bacterial cells. Consistent and reproducible species specific spectra were obtained and sensitivity up to a level of 1000 cells was observed in FTIR with a DTGS detector. This clearly shows the potential of solid state spectroscopic techniques for simple, easy to implement, reliable and sensitive detection of bacteria from environmental samples.
NASA Technical Reports Server (NTRS)
Wang, Liang-Guo; Sachse, Glen
1990-01-01
Closed-cycle CO2 laser operation with removal of O2 and regeneration of CO2 can be achieved by catalytic CO-O2 recombination. Both parametric studies of the optimum catalyst formulation and long-term performance tests require on line monitoring of CO, O2 and CO2 concentrations. There are several existing methods for molecular oxygen detection. These methods are either intrusive (such as electrochemical method or mass spectrometry) or very expensive (such as CARS, UV laser absorption). Researchers demonstrated a high-sensitivity spectroscopic measurement of O2 using the two-tone frequency modulation spectroscopy (FMS) technique with a near infrared GaAlAs diode laser. Besides its inexpensive cost, fast response time, nonintrusive measurements and high sensitivity, this technique may also be used to differentiate between isotopes due to its high spectroscopic resolution. This frequency modulation spectroscopy technique could also be applied for the on-line monitoring of CO and CO2 using InGaAsP diode lasers operation in the 1.55 microns region and H2O in the 1.3 microns region. The existence of single mode optical fibers at the near infrared region makes it possible to combine FMS with optical fiber technology. Optical fiber FMS is particularly suitable for making point-measurements at one or more locations in the CO2 laser/catalyst system.
Localization of Bovine Papillomavirus Nucleic Acid in Equine Sarcoids.
Gaynor, A M; Zhu, K W; Dela Cruz, F N; Affolter, V K; Pesavento, P A
2016-05-01
Bovine papillomaviruses (BPV1/BPV2) have long been associated with equine sarcoids; deciphering their contribution has been difficult due to their ubiquitous presence on skin and in the environment, as well as the lack of decent techniques to interrogate their role in pathogenesis. We have developed and characterized an in situ hybridization (ISH) assay that uses a pool of probes complementary to portions of the E5, E6, and E7 genes. This assay is highly sensitive for direct visualization of viral transcript and nucleic acid in routinely processed histopathologic samples. We demonstrate here the visualization of BPV nucleic acid in 18 of 18 equine sarcoids, whereas no detectable viral DNA was present in 15 of 15 nonsarcoid controls by this technique. In nearly 90% (16/18) of the sarcoids, 50% or more of the fibroblastic cell nuclei distributed throughout the neoplasm had detectable hybridization. In the remaining 2 cases, fewer than half of the fibroblastic cells contained detectable hybridization, but viral nucleic acid was also detected in epithelial cells of the sebaceous glands, hair follicles and epidermis. A sensitive ISH assay is an indispensable addition to the molecular methods used to detect viral nucleic acid in tissue. We have used this technique to determine the specific cellular localization and distribution of BPV in a subset of equine sarcoids. © The Author(s) 2015.
Moros, J; Lorenzo, J A; Laserna, J J
2011-07-01
In general, any standoff sensor for the effective detection of explosives must meet two basic requirements: first, a capacity to detect the response generated from only a small amount of material located at a distance of several meters (high sensitivity) and second, the ability to provide easily distinguishable responses for different materials (high specificity). Raman spectroscopy and laser-induced breakdown spectroscopy (LIBS) are two analytical techniques which share similar instrumentation and, at the same time, generate complementary data. These factors have been taken into account recently for the design of sensors used in the detection of explosives. Similarly, research on the proper integration of both techniques has been around for a while. A priori, the different operational conditions required by the two techniques oblige the acquisition of the response for each sensor through sequential analysis, previously necessary to define the proper hierarchy of actuation. However, such an approach does not guarantee that Raman and LIBS responses obtained may relate to each other. Nonetheless, the possible advantages arising from the integration of the molecular and elemental spectroscopic information come with an obvious underlying requirement, simultaneous data acquisition. In the present paper, strong and weak points of Raman spectroscopy and LIBS for solving explosives detection problems, in terms of selectivity, sensitivity, and throughput, are critically examined, discussed, and compared for assessing the ensuing options on the fusion of the responses of both sensing technologies.
Methods for nanoparticle labeling of ricin and effect on toxicity
NASA Astrophysics Data System (ADS)
Wark, Alastair W.; Yu, Jun; Lindsay, Christopher D.; Nativo, Paola; Graham, Duncan
2009-09-01
The unique optical properties associated with nanostructured materials that support the excitation of surface plasmons offer many new opportunities for the enhanced optical investigation of biological materials that pose a security threat. In particular, ricin is considered a significant bioterrorism risk due to its high toxicity combined with its ready availability as a byproduct in castor oil production. Therefore, the development of optical techniques capable of rapid on-site toxin detection with high molecular specificity and sensitivity continues to be of significant importance. Furthermore, understanding of the ricin cell entry and intracellular pathways remains poor due to a lack of suitable bioanalytical techniques. Initial work aimed at simultaneously tackling both these issues is described where different approaches for the nanoparticle labeling of ricin are investigated along with changes in ricin toxicity associated with the labeling process.
Stimuli-sensitive hydrogels: an excellent carrier for drug and cell delivery.
Garg, Tarun; Singh, Simranjit; Goyal, Amit Kumar
2013-01-01
The stimuli-sensitive hydrogel is an injectable formulation that is used to deliver drugs, cells, and genes into the body. Hydrogels are available in various physical forms such as solid molded, pressed powder matrix, microparticle, coating, or membrane forms. The network structure of hydrogels can be macroporous, microporous, or nonporous. Different categories of biomaterials, such as natural, synthetic, and combinations (e.g., semisynthetic such as natural-natural, natural-synthetic, and synthetic-synthetic polymers), are commonly used in hydrogel preparation. Classification of hydrogels mainly depends upon physical stimuli (temperature, electric fields, solvent composition, light, pressure, sound, and magnetic fields) and chemical or biochemical stimuli (pH, ions, and specific molecular recognition events). Several approaches for the synthesis of hydrogels have been reported, including emulsification, micromolding, photolithography, isostatic ultra high pressure, and microfluidic techniques. Hydrogels provide structural integrity and cellular organization, serve as tissue barriers, act as bioadhesive and drug depots, deliver bioactive agents and cells, and possess unique swelling properties and structures. This review provides a detailed account of the need for development of hydrogels, along with the materials used and techniques adopted to manufacture scaffolds for tissue engineering and for prolonged drug, cell, and gene delivery.