Sample records for sensitive screening methods

  1. Terbium-sensitized luminescence screening method for fluoroquinolones in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods commonly used for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay was developed...

  2. Parameter screening: the use of a dummy parameter to identify non-influential parameters in a global sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Khorashadi Zadeh, Farkhondeh; Nossent, Jiri; van Griensven, Ann; Bauwens, Willy

    2017-04-01

    Parameter estimation is a major concern in hydrological modeling, which may limit the use of complex simulators with a large number of parameters. To support the selection of parameters to include in or exclude from the calibration process, Global Sensitivity Analysis (GSA) is widely applied in modeling practices. Based on the results of GSA, the influential and the non-influential parameters are identified (i.e. parameters screening). Nevertheless, the choice of the screening threshold below which parameters are considered non-influential is a critical issue, which has recently received more attention in GSA literature. In theory, the sensitivity index of a non-influential parameter has a value of zero. However, since numerical approximations, rather than analytical solutions, are utilized in GSA methods to calculate the sensitivity indices, small but non-zero indices may be obtained for the indices of non-influential parameters. In order to assess the threshold that identifies non-influential parameters in GSA methods, we propose to calculate the sensitivity index of a "dummy parameter". This dummy parameter has no influence on the model output, but will have a non-zero sensitivity index, representing the error due to the numerical approximation. Hence, the parameters whose indices are above the sensitivity index of the dummy parameter can be classified as influential, whereas the parameters whose indices are below this index are within the range of the numerical error and should be considered as non-influential. To demonstrated the effectiveness of the proposed "dummy parameter approach", 26 parameters of a Soil and Water Assessment Tool (SWAT) model are selected to be analyzed and screened, using the variance-based Sobol' and moment-independent PAWN methods. The sensitivity index of the dummy parameter is calculated from sampled data, without changing the model equations. Moreover, the calculation does not even require additional model evaluations for the Sobol' method. A formal statistical test validates these parameter screening results. Based on the dummy parameter screening, 11 model parameters are identified as influential. Therefore, it can be denoted that the "dummy parameter approach" can facilitate the parameter screening process and provide guidance for GSA users to define a screening-threshold, with only limited additional resources. Key words: Parameter screening, Global sensitivity analysis, Dummy parameter, Variance-based method, Moment-independent method

  3. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2002-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

  4. Applying under-sampling techniques and cost-sensitive learning methods on risk assessment of breast cancer.

    PubMed

    Hsu, Jia-Lien; Hung, Ping-Cheng; Lin, Hung-Yen; Hsieh, Chung-Ho

    2015-04-01

    Breast cancer is one of the most common cause of cancer mortality. Early detection through mammography screening could significantly reduce mortality from breast cancer. However, most of screening methods may consume large amount of resources. We propose a computational model, which is solely based on personal health information, for breast cancer risk assessment. Our model can be served as a pre-screening program in the low-cost setting. In our study, the data set, consisting of 3976 records, is collected from Taipei City Hospital starting from 2008.1.1 to 2008.12.31. Based on the dataset, we first apply the sampling techniques and dimension reduction method to preprocess the testing data. Then, we construct various kinds of classifiers (including basic classifiers, ensemble methods, and cost-sensitive methods) to predict the risk. The cost-sensitive method with random forest classifier is able to achieve recall (or sensitivity) as 100 %. At the recall of 100 %, the precision (positive predictive value, PPV), and specificity of cost-sensitive method with random forest classifier was 2.9 % and 14.87 %, respectively. In our study, we build a breast cancer risk assessment model by using the data mining techniques. Our model has the potential to be served as an assisting tool in the breast cancer screening.

  5. Global sensitivity analysis for urban water quality modelling: Terminology, convergence and comparison of different methods

    NASA Astrophysics Data System (ADS)

    Vanrolleghem, Peter A.; Mannina, Giorgio; Cosenza, Alida; Neumann, Marc B.

    2015-03-01

    Sensitivity analysis represents an important step in improving the understanding and use of environmental models. Indeed, by means of global sensitivity analysis (GSA), modellers may identify both important (factor prioritisation) and non-influential (factor fixing) model factors. No general rule has yet been defined for verifying the convergence of the GSA methods. In order to fill this gap this paper presents a convergence analysis of three widely used GSA methods (SRC, Extended FAST and Morris screening) for an urban drainage stormwater quality-quantity model. After the convergence was achieved the results of each method were compared. In particular, a discussion on peculiarities, applicability, and reliability of the three methods is presented. Moreover, a graphical Venn diagram based classification scheme and a precise terminology for better identifying important, interacting and non-influential factors for each method is proposed. In terms of convergence, it was shown that sensitivity indices related to factors of the quantity model achieve convergence faster. Results for the Morris screening method deviated considerably from the other methods. Factors related to the quality model require a much higher number of simulations than the number suggested in literature for achieving convergence with this method. In fact, the results have shown that the term "screening" is improperly used as the method may exclude important factors from further analysis. Moreover, for the presented application the convergence analysis shows more stable sensitivity coefficients for the Extended-FAST method compared to SRC and Morris screening. Substantial agreement in terms of factor fixing was found between the Morris screening and Extended FAST methods. In general, the water quality related factors exhibited more important interactions than factors related to water quantity. Furthermore, in contrast to water quantity model outputs, water quality model outputs were found to be characterised by high non-linearity.

  6. Comparison of real-time PCR with disk diffusion, agar screen and E-test methods for detection of methicillin-resistant Staphylococcus aureus.

    PubMed

    Shariati, Laleh; Validi, Majid; Tabatabaiefar, Mohammad Amin; Karimi, Ali; Nafisi, Mohammad Reza

    2010-12-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a nosocomial pathogen. Our main objective was to compare oxacillin disk test, oxacillin E-test, and oxacillin agar screen for detection of methicillin resistance in S. aureus, using real-time PCR for mecA as the "gold standard" comparison assay. 196 S. aureus isolates were identified out of 284 Staphylococcus isolates. These isolates were screened for MRSA with several methods: disk diffusion, agar screen (6.0 μg/ml), oxacillin E-test, and real-time PCR for detection of mecA gene. Of the 196 S. aureus isolates tested, 96 isolates (49%) were mecA-positive and 100 isolates (51%) mecA-negative. All methods tested had a statistically significant agreement with real-time PCR. E-test was 100% sensitive and specific for mecA presence. The sensitivity and specificity of oxacillin agar screen method were 98 and 99%, respectively and sensitivity and specificity of oxacillin disk diffusion method were 95 and 93%, respectively. In the present study, oxacillin E-test is proposed as the best phenotypic method. For economic reasons, the oxacillin agar screen method (6.0 μg/ml), which is suitable for the detection of MRSA, is recommended due to its accuracy and low cost.

  7. Rapid automated method for screening of enteric pathogens from stool specimens.

    PubMed Central

    Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C

    1987-01-01

    A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230

  8. Global Sensitivity Analysis of Environmental Models: Convergence, Robustness and Validation

    NASA Astrophysics Data System (ADS)

    Sarrazin, Fanny; Pianosi, Francesca; Khorashadi Zadeh, Farkhondeh; Van Griensven, Ann; Wagener, Thorsten

    2015-04-01

    Global Sensitivity Analysis aims to characterize the impact that variations in model input factors (e.g. the parameters) have on the model output (e.g. simulated streamflow). In sampling-based Global Sensitivity Analysis, the sample size has to be chosen carefully in order to obtain reliable sensitivity estimates while spending computational resources efficiently. Furthermore, insensitive parameters are typically identified through the definition of a screening threshold: the theoretical value of their sensitivity index is zero but in a sampling-base framework they regularly take non-zero values. There is little guidance available for these two steps in environmental modelling though. The objective of the present study is to support modellers in making appropriate choices, regarding both sample size and screening threshold, so that a robust sensitivity analysis can be implemented. We performed sensitivity analysis for the parameters of three hydrological models with increasing level of complexity (Hymod, HBV and SWAT), and tested three widely used sensitivity analysis methods (Elementary Effect Test or method of Morris, Regional Sensitivity Analysis, and Variance-Based Sensitivity Analysis). We defined criteria based on a bootstrap approach to assess three different types of convergence: the convergence of the value of the sensitivity indices, of the ranking (the ordering among the parameters) and of the screening (the identification of the insensitive parameters). We investigated the screening threshold through the definition of a validation procedure. The results showed that full convergence of the value of the sensitivity indices is not necessarily needed to rank or to screen the model input factors. Furthermore, typical values of the sample sizes that are reported in the literature can be well below the sample sizes that actually ensure convergence of ranking and screening.

  9. An Efficient Variable Screening Method for Effective Surrogate Models for Reliability-Based Design Optimization

    DTIC Science & Technology

    2014-04-01

    surrogate model generation is difficult for high -dimensional problems, due to the curse of dimensionality. Variable screening methods have been...a variable screening model was developed for the quasi-molecular treatment of ion-atom collision [16]. In engineering, a confidence interval of...for high -level radioactive waste [18]. Moreover, the design sensitivity method can be extended to the variable screening method because vital

  10. Pyridoxylamine reactivity kinetics as an amine based nucleophile for screening electrophilic dermal sensitizers

    PubMed Central

    Chipinda, Itai; Mbiya, Wilbes; Adigun, Risikat Ajibola; Morakinyo, Moshood K.; Law, Brandon F.; Simoyi, Reuben H.; Siegel, Paul D.

    2015-01-01

    Chemical allergens bind directly, or after metabolic or abiotic activation, to endogenous proteins to become allergenic. Assessment of this initial binding has been suggested as a target for development of assays to screen chemicals for their allergenic potential. Recently we reported a nitrobenzenethiol (NBT) based method for screening thiol reactive skin sensitizers, however, amine selective sensitizers are not detected by this assay. In the present study we describe an amine (pyridoxylamine (PDA)) based kinetic assay to complement the NBT assay for identification of amine-selective and non-selective skin sensitizers. UV-Vis spectrophotometry and fluorescence were used to measure PDA reactivity for 57 chemicals including anhydrides, aldehydes, and quinones where reaction rates ranged from 116 to 6.2 × 10−6 M−1 s−1 for extreme to weak sensitizers, respectively. No reactivity towards PDA was observed with the thiol-selective sensitizers, non-sensitizers and prohaptens. The PDA rate constants correlated significantly with their respective murine local lymph node assay (LLNA) threshold EC3 values (R2 = 0.76). The use of PDA serves as a simple, inexpensive amine based method that shows promise as a preliminary screening tool for electrophilic, amine-selective skin sensitizers. PMID:24333919

  11. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  12. Comparative Evaluation of Preliminary Screening Methods for Colorectal Cancer in a Mass Program.

    PubMed

    Ye, Ding; Huang, Qiuchi; Li, Qilong; Jiang, Xiyi; Mamat, Mayila; Tang, Mengling; Wang, Jianbing; Chen, Kun

    2017-09-01

    The fecal immunochemical test (FIT) has been widely used in preliminary screening for colorectal cancer (CRC). The high-risk factor questionnaire (HRFQ) and quantitative risk-assessment method (QRAM) are recommended for estimating the risk of CRC qualitatively and quantitatively in China. We aimed to prospectively compare the diagnostic values of CRC preliminary screening methods to identify which method is preferable as a screening strategy. Individuals aged 40-74 years old were enrolled in a mass CRC screening program from January 1, 2007 to December 31, 2014, in Jiashan County, Zhejiang Province, China. FIT of two stool specimens at 1-week intervals was performed by laboratory personnel and face-to-face interviews were conducted by trained investigators. Screening data in the program were linked to a CRC surveillance and registry system, and CRC cases reported in the system were regarded as true patients. A total of 96,043 subjects were included. The sensitivity and specificity of FIT for detecting CRC cases were 75.49% (95% CI 69.84-80.39) and 90.36% (95% CI 90.17-90.54), respectively. QRAM was more sensitive (p < 0.001) and less specific (p < 0.001) than HRFQ. The sensitivity and specificity of FIT along with HRFQ were 86.56% (95% CI 81.81-90.22) and 81.37% (95% CI 81.12-81.62), and those of FIT along with QRAM were 88.93% (95% CI 84.47-92.23) and 73.95% (95% CI 73.67-74.23). Our findings suggest that CRC preliminary screening with FIT and QRAM in parallel has high sensitivity and satisfactory specificity, and is a useful strategy in mass screening programs.

  13. Engineering 'cell robots' for parallel and highly sensitive screening of biomolecules under in vivo conditions.

    PubMed

    Song, Lifu; Zeng, An-Ping

    2017-11-09

    Cells are capable of rapid replication and performing tasks adaptively and ultra-sensitively and can be considered as cheap "biological-robots". Here we propose to engineer cells for screening biomolecules in parallel and with high sensitivity. Specifically, we place the biomolecule variants (library) on the bacterial phage M13. We then design cells to screen the library based on cell-phage interactions mediated by a specific intracellular signal change caused by the biomolecule of interest. For proof of concept, we used intracellular lysine concentration in E. coli as a signal to successfully screen variants of functional aspartate kinase III (AK-III) under in vivo conditions, a key enzyme in L-lysine biosynthesis which is strictly inhibited by L-lysine. Comparative studies with flow cytometry method failed to distinguish the wild-type from lysine resistance variants of AK-III, confirming a higher sensitivity of the method. It opens up a new and effective way of in vivo high-throughput screening for functional molecules and can be easily implemented at low costs.

  14. What are the most effective methods for assessment of nutritional status in outpatients with gastric and colorectal cancer?

    PubMed

    Abe Vicente, Mariana; Barão, Katia; Silva, Tiago Donizetti; Forones, Nora Manoukian

    2013-01-01

    To evaluate methods for the identification of nutrition risk and nutritional status in outpatients with colorectal (CRC) and gastric cancer (GC), and to compare the results to those obtained for patients already treated for these cancers. A cross-sectional study was conducted on 137 patients: group 1 (n = 75) consisting of patients with GC or CRC, and group 2 (n = 62) consisting of patients after treatment of GC or CRC under follow up, who were tumor free for a period longer than 3 months. Nutritional status was assessed in these patients using objective methods [body mass index (BMI), phase angle, serum albumin]; nutritional screening tools [Malnutrition Universal Screening Tool (MUST), Malnutrition Screening Tool (MST), Nutritional Risk Index (NRI)], and subjective assessment [Patient-Generated Subjective Global Assessment (PGSGA)]. The sensitivity and specificity of each method was calculated in relation to the PG-SGA used as gold standard. One hundred thirty seven patients participated in the study. Stage IV cancer patients were more common in group 1. There was no difference in BMI between groups (p = 0.67). Analysis of the association between methods of assessing nutritional status and PG-SGA showed that the nutritional screening tools provided more significant results (p < 0.05) than the objective methods in the two groups. PG-SGA detected the highest proportion of undernourished patients in group 1. The nutritional screening tools MUST, NRI and MST were more sensitive than the objective methods. Phase angle measurement was the most sensitive objective method in group 1. The nutritional screening tools showed the best association with PG-SGA and were also more sensitive than the objective methods. The results suggest the combination of MUST and PG-SGA for patients with cancer before and after treatment. Copyright © AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  15. Frailty screening methods for predicting outcome of a comprehensive geriatric assessment in elderly patients with cancer: a systematic review.

    PubMed

    Hamaker, Marije E; Jonker, Judith M; de Rooij, Sophia E; Vos, Alinda G; Smorenburg, Carolien H; van Munster, Barbara C

    2012-10-01

    Comprehensive geriatric assessment (CGA) is done to detect vulnerability in elderly patients with cancer so that treatment can be adjusted accordingly; however, this process is time-consuming and pre-screening is often used to identify fit patients who are able to receive standard treatment versus those in whom a full CGA should be done. We aimed to assess which of the frailty screening methods available show the best sensitivity and specificity for predicting the presence of impairments on CGA in elderly patients with cancer. We did a systematic search of Medline and Embase, and a hand-search of conference abstracts, for studies on the association between frailty screening outcome and results of CGA in elderly patients with cancer. Our search identified 4440 reports, of which 22 publications from 14 studies, were included in this Review. Seven different frailty screening methods were assessed. The median sensitivity and specificity of each screening method for predicting frailty on CGA were as follows: Vulnerable Elders Survey-13 (VES-13), 68% and 78%; Geriatric 8 (G8), 87% and 61%; Triage Risk Screening Tool (TRST 1+; patient considered frail if one or more impairments present), 92% and 47%, Groningen Frailty Index (GFI) 57% and 86%, Fried frailty criteria 31% and 91%, Barber 59% and 79%, and abbreviated CGA (aCGA) 51% and 97%. However, even in case of the highest sensitivity, the negative predictive value was only roughly 60%. G8 and TRST 1+ had the highest sensitivity for frailty, but both had poor specificity and negative predictive value. These findings suggest that, for now, it might be beneficial for all elderly patients with cancer to receive a complete geriatric assessment, since available frailty screening methods have insufficient discriminative power to select patients for further assessment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Time-resolved luminescence screening method for enrofloxacin in beef serum

    USDA-ARS?s Scientific Manuscript database

    Enrofloxacin is one of only two fluoroquinolone antibiotics approved for use in cattle in the U.S. Microbial screening methods currently used in the U.S. for monitoring veterinary drug residues are not sensitive or selective for fluoroquinolones. In this work, a luminescence-based screening assay ...

  17. Biomarkers of Acute Respiratory Allergen Exposure: Screening For Sensitization Potential

    EPA Science Inventory

    Rationale: An in vitro assay to identify respiratory sensitizers will provide a rapid screen and reduce animal use. The study goal was to identify biomarkers that differentiate allergen versus non-allergen responses following an acute exposure. Methods: Female BALB/c mice rec...

  18. Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.

    PubMed

    Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P

    2007-04-01

    To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.

  19. [Possibilities of the TruScreen for screening of precancer and cancer of the uterine cervix].

    PubMed

    Zlatkov, V

    2009-01-01

    The classic approach of detection of pre-cancer and cancer of uterine cervix includes cytological examination, followed by colposcopy assessment of the detected cytological abnormalities. Real-time devices use in-vivo techniques for the measurement, computerized analysis and classifying of different types of cervical tissues. The aim of the present review is to present the technical characteristics and to discus the diagnostic possibilities of TruScreen-automated optical-electron system for cervical screening. The analysis of the presented in the literature diagnostic value of the method at different grades intraepithelial lesions shows that it has higher sensitivity (67-70%) and lower specificity (81%) in comparison to the Pap test with the following results (45-69% sensitivity and 95% specificity). This makes the method suitable for independent primary screening, as well as for adding the diagnostic assurance of the cytological method.

  20. How to select the correct education strategy: when not to go online.

    PubMed

    Klingbeil, Carol G; Johnson, Norah L; Totka, Joan P; Doyle, Lynn

    2009-01-01

    Screening for intimate partner violence is an important injury prevention strategy. Nurses who develop staff education, to promote screening, need to select a method that is sensitive to learners. Online learning, although convenient, is not well suited to sensitive topics such as screening for intimate partner violence. The purpose of this article is to describe a curriculum for intimate partner violence screening based on self-efficacy theory, which includes a hospital-produced video, a role play, and a discussion.

  1. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. [Parameter sensitivity of simulating net primary productivity of Larix olgensis forest based on BIOME-BGC model].

    PubMed

    He, Li-hong; Wang, Hai-yan; Lei, Xiang-dong

    2016-02-01

    Model based on vegetation ecophysiological process contains many parameters, and reasonable parameter values will greatly improve simulation ability. Sensitivity analysis, as an important method to screen out the sensitive parameters, can comprehensively analyze how model parameters affect the simulation results. In this paper, we conducted parameter sensitivity analysis of BIOME-BGC model with a case study of simulating net primary productivity (NPP) of Larix olgensis forest in Wangqing, Jilin Province. First, with the contrastive analysis between field measurement data and the simulation results, we tested the BIOME-BGC model' s capability of simulating the NPP of L. olgensis forest. Then, Morris and EFAST sensitivity methods were used to screen the sensitive parameters that had strong influence on NPP. On this basis, we also quantitatively estimated the sensitivity of the screened parameters, and calculated the global, the first-order and the second-order sensitivity indices. The results showed that the BIOME-BGC model could well simulate the NPP of L. olgensis forest in the sample plot. The Morris sensitivity method provided a reliable parameter sensitivity analysis result under the condition of a relatively small sample size. The EFAST sensitivity method could quantitatively measure the impact of simulation result of a single parameter as well as the interaction between the parameters in BIOME-BGC model. The influential sensitive parameters for L. olgensis forest NPP were new stem carbon to new leaf carbon allocation and leaf carbon to nitrogen ratio, the effect of their interaction was significantly greater than the other parameter' teraction effect.

  3. Sensitive fluorimetric assays for α-glucosidase activity and inhibitor screening based on β-cyclodextrin-coated quantum dots.

    PubMed

    Liu, Si-Yao; Wang, Huan; He, Tian; Qi, Liang; Zhang, Zhi-Qi

    2016-02-01

    A fluorescence method was established for a α-glucosidase activity assay and inhibitor screening based on β-cyclodextrin-coated quantum dots. p-Nitrophenol, the hydrolysis product of the α-glucosidase reaction, could quench the fluorescence of β-cyclodextrin-coated quantum dots via an electron transfer process, leading to fluorescence turn-off, whereas the fluorescence of the system turned on in the presence of α-glucosidase inhibitors. Taking advantage of the excellent properties of quantum dots, this method provided a very simple, rapid and sensitive screening method for α-glucosidase inhibitors. Two α-glucosidase inhibitors, 2,4,6-tribromophenol and acarbose, were used to evaluate the feasibility of this screening model, and IC50 values of 24 μM and 0.55 mM were obtained respectively, which were lower than those previously reported. The method may have potential application in screening α-glucosidase inhibitors. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Sensitivity and specificity of mammographic screening as practised in Vermont and Norway

    PubMed Central

    Hofvind, S; Geller, B M; Skelly, J; Vacek, P M

    2012-01-01

    Objective The aim of this study was to examine the sensitivity and specificity of screening mammography as performed in Vermont, USA, and Norway. Methods Incident screening data from 1997 to 2003 for female patients aged 50–69 years from the Vermont Breast Cancer Surveillance System (116 996 subsequent screening examinations) and the Norwegian Breast Cancer Screening Program (360 872 subsequent screening examinations) were compared. Sensitivity and specificity estimates for the initial (based on screening mammogram only) and final (screening mammogram plus any further diagnostic imaging) interpretations were directly adjusted for age using 5-year age intervals for the combined Vermont and Norway population, and computed for 1 and 2 years of follow-up, which ended at the time of the next screening mammogram. Results For the 1-year follow-up, sensitivities for initial assessments were 82.0%, 88.2% and 92.5% for 1-, 2- and >2-year screening intervals, respectively, in Vermont (p=0.022). For final assessments, the values were 73.6%, 83.3% and 81.2% (p=0.047), respectively. For Norway, sensitivities for initial assessments were 91.0% and 91.3% (p=0.529) for 2- and >2-year intervals, and 90.7% and 91.3%, respectively, for final assessments (p=0.630). Specificity was lower in Vermont than in Norway for each screening interval and for all screening intervals combined, for both initial (90.6% vs 97.8% for all intervals; p<0.001) and final (98.8% vs 99.5% for all intervals; p<0.001) assessments. Conclusion Our study showed higher sensitivity and specificity in a biennial screening programme with an independent double reading than in a predominantly annual screening program with a single reading. Advances in knowledge This study demonstrates that higher recall rates and lower specificity are not always associated with higher sensitivity of screening mammography. Differences in the screening processes in Norway and Vermont suggest potential areas for improvement in the latter. PMID:22993383

  5. Role of re-screening of cervical smears in internal quality control.

    PubMed Central

    Baker, A; Melcher, D; Smith, R

    1995-01-01

    AIMS--To investigate the use of rapid re-screening as a quality control method for previously screened cervical slides; to compare this method with 10% random re-screening and clinically indicated double screening. METHODS--Between June 1990 and December 1994, 117,890 negative smears were subjected to rapid re-screening. RESULTS--This study shows that rapid re-screening detects far greater numbers of false negative cases when compared with both 10% random re-screening and clinically indicated double screening, with no additional demand on human resources. The technique also identifies variation in the performance of screening personnel as an additional benefit. CONCLUSION--Rapid re-screening is an effective method of quality control. Although less sensitive, rapid re-screening should replace 10% random re-screening and selected re-screening as greater numbers of false negative results are detected while consuming less resources. PMID:8543619

  6. [Sensitivity and specificity of the breast screening program in the Isere region based on positive results between 1991 and 1999].

    PubMed

    Garnier, A; Poncet, F; Billette De Villemeur, A; Exbrayat, C; Bon, M F; Chevalier, A; Salicru, B; Tournegros, J M

    2009-06-01

    The screening program guidelines specify that the call back rate of women for additional imaging (positive mammogram) should not exceed 7% at initial screening, and 5% at subsequent screening. Materials and methods. Results in the Isere region (12%) have prompted a review of the correlation between the call back rate and indicators of quality (detection rate, sensitivity, specificity, positive predictive value) for the radiologists providing interpretations during that time period. Three groups of radiologists were identified: the group with call back rate of 10% achieved the best results (sensitivity: 92%, detection rate: 0.53%, specificity: 90%). The group with lowest call back rate (7.7%) showed insufficient sensitivity (58%). The last group with call back rate of 18.3%, showed no improvement in sensitivity (82%) and detection rate (0.53%), but showed reduced specificity (82%). The protocol update in 2001 does not resolve this problematic situation and national results continue to demonstrate a high percentage of positive screening mammograms. A significant increase in the number of positive screening examinations compared to recommended guidelines is not advantageous and leads to an overall decrease in the quality of the screening.

  7. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  8. A comprehensive evaluation of various sensitivity analysis methods: A case study with a hydrological model

    DOE PAGES

    Gan, Yanjun; Duan, Qingyun; Gong, Wei; ...

    2014-01-01

    Sensitivity analysis (SA) is a commonly used approach for identifying important parameters that dominate model behaviors. We use a newly developed software package, a Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), to evaluate the effectiveness and efficiency of ten widely used SA methods, including seven qualitative and three quantitative ones. All SA methods are tested using a variety of sampling techniques to screen out the most sensitive (i.e., important) parameters from the insensitive ones. The Sacramento Soil Moisture Accounting (SAC-SMA) model, which has thirteen tunable parameters, is used for illustration. The South Branch Potomac River basin nearmore » Springfield, West Virginia in the U.S. is chosen as the study area. The key findings from this study are: (1) For qualitative SA methods, Correlation Analysis (CA), Regression Analysis (RA), and Gaussian Process (GP) screening methods are shown to be not effective in this example. Morris One-At-a-Time (MOAT) screening is the most efficient, needing only 280 samples to identify the most important parameters, but it is the least robust method. Multivariate Adaptive Regression Splines (MARS), Delta Test (DT) and Sum-Of-Trees (SOT) screening methods need about 400–600 samples for the same purpose. Monte Carlo (MC), Orthogonal Array (OA) and Orthogonal Array based Latin Hypercube (OALH) are appropriate sampling techniques for them; (2) For quantitative SA methods, at least 2777 samples are needed for Fourier Amplitude Sensitivity Test (FAST) to identity parameter main effect. McKay method needs about 360 samples to evaluate the main effect, more than 1000 samples to assess the two-way interaction effect. OALH and LPτ (LPTAU) sampling techniques are more appropriate for McKay method. For the Sobol' method, the minimum samples needed are 1050 to compute the first-order and total sensitivity indices correctly. These comparisons show that qualitative SA methods are more efficient but less accurate and robust than quantitative ones.« less

  9. A Novel Quantum Dots-Based Point of Care Test for Syphilis

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang

    2010-05-01

    One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.

  10. Test, episode, and programme sensitivities of screening for colorectal cancer as a public health policy in Finland: experimental design.

    PubMed

    Malila, Nea; Oivanen, Tiina; Malminiemi, Outi; Hakama, Matti

    2008-11-20

    To report the sensitivities of the faecal occult blood test, screening episode, and screening programme for colorectal cancer and the benefits of applying a randomised design at the implementation phase of a new public health policy. Experimental design incorporated in public health evaluation using randomisation at individual level in the target population. 161 of the 431 Finnish municipalities in 2004-6. 106 000 adults randomised to screening or control arms. In total, 52 998 adults aged 60-64 in the screening arm received faecal occult blood test kits. Test, episode, and programme sensitivities estimated by the incidence method and corrected for selective attendance and overdiagnosis. The response for screening was high overall (70.8%), and significantly better in women (78.1%) than in men (63.3%). The incidence of cancer in the controls was somewhat higher in men than in women (103 v 93 per 100 000 person years), which was not true for interval cancers (42 v 49 per 100 000 person years). The sensitivity of the faecal occult blood test was 54.6%. Only a few interval cancers were detected among those with positive test results, hence the episode sensitivity of 51.3% was close to the test sensitivity. At the population level the sensitivity of the programme was 37.5%. Although relatively low, the sensitivity of screening for colorectal cancer with the faecal occult blood test in Finland was adequate. An experimental design is a prerequisite for evaluation of such a screening programme because the effectiveness of preventing deaths is likely to be small and results may otherwise remain inconclusive. Thus, screening for colorectal cancer using any primary test modality should be launched in a public health programme with randomisation of the target population at the implementation phase.

  11. Rapid screening of tannase producing microbes by using natural tannin

    PubMed Central

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-01-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes. PMID:24031931

  12. Rapid screening of tannase producing microbes by using natural tannin.

    PubMed

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-07-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes.

  13. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Population and High-Risk Group Screening for Glaucoma: The Los Angeles Latino Eye Study

    PubMed Central

    Francis, Brian A.; Vigen, Cheryl; Lai, Mei-Ying; Winarko, Jonathan; Nguyen, Betsy; Azen, Stanley

    2011-01-01

    Purpose. To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups. Methods. The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening. Results. Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters—C/D, HVF, and IOP—substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92). Conclusions. No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs. PMID:21245400

  15. Reliability and Validity of Observational Risk Screening in Evaluating Dynamic Knee Valgus

    PubMed Central

    Ekegren, Christina L.; Miller, William C.; Celebrini, Richard G.; Eng, Janice J.; MacIntyre, Donna L.

    2012-01-01

    Study Design Nonexperimental methodological study. Objectives To determine the interrater and intrarater reliability and validity of using observational risk screening guidelines to evaluate dynamic knee valgus. Background A deficiency in the neuromuscular control of the hip has been identified as a key risk factor for non-contact anterior cruciate ligament (ACL) injury in post pubescent females. This deficiency can manifest itself as a valgus knee alignment during tasks involving hip and knee flexion. There are currently no scientifically tested methods to screen for dynamic knee valgus in the clinic or on the field. Methods Three physiotherapists used observational risk screening guidelines to rate 40 adolescent female soccer players according to their risk of ACL injury. The rating was based on the amount of dynamic knee valgus observed on a drop jump landing. Ratings were evaluated for intrarater and interrater agreement using kappa coefficients. Sensitivity and specificity of ratings were evaluated by comparing observational ratings with measurements obtained using 3-dimensional (3D) motion analysis. Results Kappa coefficients for intrarater and interrater agreement ranged from 0.75 to 0.85, indicating that ratings were reasonably consistent over time and between physiotherapists. Sensitivity values were inadequate, ranging from 67–87%. This indicated that raters failed to detect up to a third of “truly high risk” individuals. Specificity values ranged from 60–72% which was considered adequate for the purposes of the screen. Conclusion Observational risk screening is a practical and cost-effective method of screening for ACL injury risk. Rater agreement and specificity were acceptable for this method but sensitivity was not. To detect a greater proportion of individuals at risk of ACL injury, coaches and clinicians should ensure that they include additional tests for other high risk characteristics in their screening protocols. PMID:19721212

  16. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  17. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    USDA-ARS?s Scientific Manuscript database

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization integrated approaches combining different chemical, biological and in silico methods are recommended to r...

  18. Improvement of screening methods for silicon planar semiconductor devices

    NASA Technical Reports Server (NTRS)

    Berger, W. M.

    1972-01-01

    The results of the program for the development of a more sensitive method for selecting silicon planar semiconductor devices for long life applications are reported. The manufacturing technologies (MOS and Bipolar) are discussed along with the screening procedures developed as a result of the tests and evaluations, and the effectiveness of the MOS and Bilayer screening procedures are evaluated.

  19. On the Validity and Sensitivity of the Phonics Screening Check: Erratum and Further Analysis

    ERIC Educational Resources Information Center

    Gilchrist, James M.; Snowling, Margaret J.

    2018-01-01

    Duff, Mengoni, Bailey and Snowling ("Journal of Research in Reading," 38: 109-123; 2015) evaluated the sensitivity and specificity of the phonics screening check against two reference standards. This report aims to correct a minor data error in the original article and to present further analysis of the data. The methods used are…

  20. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis

    PubMed Central

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine MA; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-01-01

    Background: We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Methods: Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. Results: In BRCA1/2 mutation carriers of all ages (BRCA1=1219 and BRCA2=732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P>0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Conclusions: Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering. PMID:26908327

  1. In vitro methods for hazard assessment of industrial chemicals – opportunities and challenges

    PubMed Central

    Wong, Chin Lin; Ghassabian, Sussan; Smith, Maree T.; Lam, Ai-Leen

    2015-01-01

    Allergic contact dermatitis (ACD) is a delayed-type hypersensitivity immune reaction mediated by T-lymphocytes as a result of repeated exposure of an allergen primarily on skin. ACD accounts for up to 95% of occupational skin diseases, with epoxy resins implicated as one of the most common causes of ACD. Efficient high-throughput in vitro screening for accurate identification of compounds and materials that may pose hazardous risks in the workplace is crucial. At present, the murine local lymph node assay is the ‘method of choice’ for predicting the sensitizing potency of contact allergens. As the 3Rs principles of reduction, refinement, and replacement in animal testing has gained political and economic momentum, several in vitro screening methods have been developed for identifying potential contact allergens. To date, these latter methods have been utilized primarily to assess the skin sensitizing potential of the chemical components of cosmetic products with scant research attention as to the applicability of these methods to industrial chemicals, particularly epoxy resins. Herein we review the currently utilized in vitro methods and identify the knowledge gaps with regard to assessing the generalizability of in vitro screening methods for assessing the skin sensitizing potential of industrial chemicals. PMID:25999858

  2. In vitro methods for hazard assessment of industrial chemicals - opportunities and challenges.

    PubMed

    Wong, Chin Lin; Ghassabian, Sussan; Smith, Maree T; Lam, Ai-Leen

    2015-01-01

    Allergic contact dermatitis (ACD) is a delayed-type hypersensitivity immune reaction mediated by T-lymphocytes as a result of repeated exposure of an allergen primarily on skin. ACD accounts for up to 95% of occupational skin diseases, with epoxy resins implicated as one of the most common causes of ACD. Efficient high-throughput in vitro screening for accurate identification of compounds and materials that may pose hazardous risks in the workplace is crucial. At present, the murine local lymph node assay is the 'method of choice' for predicting the sensitizing potency of contact allergens. As the 3Rs principles of reduction, refinement, and replacement in animal testing has gained political and economic momentum, several in vitro screening methods have been developed for identifying potential contact allergens. To date, these latter methods have been utilized primarily to assess the skin sensitizing potential of the chemical components of cosmetic products with scant research attention as to the applicability of these methods to industrial chemicals, particularly epoxy resins. Herein we review the currently utilized in vitro methods and identify the knowledge gaps with regard to assessing the generalizability of in vitro screening methods for assessing the skin sensitizing potential of industrial chemicals.

  3. Sensitivity and specificity of different methods for cystic fibrosis-related diabetes screening: is the oral glucose tolerance test still the standard?

    PubMed

    Mainguy, Catherine; Bellon, Gabriel; Delaup, Véronique; Ginoux, Tiphanie; Kassai-Koupai, Behrouz; Mazur, Stéphane; Rabilloud, Muriel; Remontet, Laurent; Reix, Philippe

    2017-01-01

    Cystic fibrosis-related diabetes (CFRD) is a late cystic fibrosis (CF)-associated comorbidity whose prevalence is increasing sharply lifelong. Guidelines for glucose metabolism (GM) monitoring rely on the oral glucose tolerance test (OGTT). However, this test is neither sensitive nor specific. The aim of this study was to compare sensitivity and specificity of different methods for GM monitoring in children and adolescents with CF. Continuous glucose monitoring system (CGMS), used as the reference method, was compared with the OGTT, intravenous glucose tolerance test (IGTT), homeostasis model assessment index of insulin resistance (HOMA-IR), homeostasis model assessment index of β-cell function (HOMA-%B) and glycated haemoglobin A1C. Patients were classified into three groups according to CGMS: normal glucose tolerance (NGT), impaired glucose tolerance (IGT) and diabetes mellitus (DM). Twenty-nine patients (median age: 13.1 years) were recruited. According to CGMS, 11 had DM, 12 IGT and six NGT, whereas OGTT identified three patients with DM and five with IGT. While 13 of 27 had insulin deficiency according to IGTT, there was 19 of 28 according to HOMA-%B. According to HOMA-IR, 12 of 28 had insulin resistance. HOMA-%B was the most sensitive method for CFRD screening [sensitivity 91% (95% CI), specificity 47% (95% CI) and negative predictive value 89% (95% CI)]. OGTT showed the weak capacity to diagnose DM in CF and should no longer be considered as the reference method for CFRD screening in patients with CF. In our study, HOMA-%B showed promising metrics for CFRD screening. Finally, CGMS revealed that pathological glucose excursions were frequent even early in life.

  4. Eliciting population preferences for mass colorectal cancer screening organization.

    PubMed

    Nayaradou, Maximilien; Berchi, Célia; Dejardin, Olivier; Launoy, Guy

    2010-01-01

    The implementation of mass colorectal cancer (CRC) screening is a public health priority. Population participation is fundamental for the success of CRC screening as for any cancer screening program. The preferences of the population may influence their likelihood of participation. The authors sought to elicit population preferences for CRC screening test characteristics to improve the design of CRC screening campaigns. A discrete choice experiment was used. Questionnaires were compiled with a set of pairs of hypothetical CRC screening scenarios. The survey was conducted by mail from June 2006 to October 2006 on a representative sample of 2000 inhabitants, aged 50 to 74 years from the northwest of France, who were randomly selected from electoral lists. Questionnaires were sent to 2000 individuals, each of whom made 3 or 4 discrete choices between hypothetical tests that differed in 7 attributes: how screening is offered, process, sensitivity, rate of unnecessary colonoscopy, expected mortality reduction, method of screening test result transmission, and cost. Complete responses were received from 656 individuals (32.8%). The attributes that influenced population preferences included expected mortality reduction, sensitivity, cost, and process. Participants from high social classes were particularly influenced by sensitivity. The results demonstrate that the discrete choice experiment provides information on patient preferences for CRC screening: improving screening program effectiveness, for instance, by improving test sensitivity (the most valued attribute) would increase satisfaction among the general population with regard to CRC screening programs. Additional studies are required to study how patient preferences actually affect adherence to regular screening programs.

  5. Highly sensitive screening method for nitroaromatic, nitramine and nitrate ester explosives by high performance liquid chromatography-atmospheric pressure ionization-mass spectrometry (HPLC-API-MS) in forensic applications.

    PubMed

    Xu, Xiaoma; van de Craats, Anick M; de Bruyn, Peter C A M

    2004-11-01

    A highly sensitive screening method based on high performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC-API-MS) has been developed for the analysis of 21 nitroaromatic, nitramine and nitrate ester explosives, which include the explosives most commonly encountered in forensic science. Two atmospheric pressure ionization (API) methods, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), and various experimental conditions have been applied to allow for the detection of all 21 explosive compounds. The limit of detection (LOD) in the full-scan mode has been found to be 0.012-1.2 ng on column for the screening of most explosives investigated. For nitrobenzene, an LOD of 10 ng was found with the APCI method in the negative mode. Although the detection of nitrobenzene, 2-, 3-, and 4-nitrotoluene is hindered by the difficult ionization of these compounds, we have found that by forming an adduct with glycine, LOD values in the range of 3-16 ng on column can be achieved. Compared with previous screening methods with thermospray ionization, the API method has distinct advantages, including simplicity and stability of the method applied, an extended screening range and a low detection limit for the explosives studied.

  6. Improving multi-objective reservoir operation optimization with sensitivity-informed dimension reduction

    NASA Astrophysics Data System (ADS)

    Chu, J.; Zhang, C.; Fu, G.; Li, Y.; Zhou, H.

    2015-08-01

    This study investigates the effectiveness of a sensitivity-informed method for multi-objective operation of reservoir systems, which uses global sensitivity analysis as a screening tool to reduce computational demands. Sobol's method is used to screen insensitive decision variables and guide the formulation of the optimization problems with a significantly reduced number of decision variables. This sensitivity-informed method dramatically reduces the computational demands required for attaining high-quality approximations of optimal trade-off relationships between conflicting design objectives. The search results obtained from the reduced complexity multi-objective reservoir operation problems are then used to pre-condition the full search of the original optimization problem. In two case studies, the Dahuofang reservoir and the inter-basin multi-reservoir system in Liaoning province, China, sensitivity analysis results show that reservoir performance is strongly controlled by a small proportion of decision variables. Sensitivity-informed dimension reduction and pre-conditioning are evaluated in their ability to improve the efficiency and effectiveness of multi-objective evolutionary optimization. Overall, this study illustrates the efficiency and effectiveness of the sensitivity-informed method and the use of global sensitivity analysis to inform dimension reduction of optimization problems when solving complex multi-objective reservoir operation problems.

  7. Performance of the EUCAST Disk Diffusion Method, the CLSI Agar Screen Method, and the Vitek 2 Automated Antimicrobial Susceptibility Testing System for Detection of Clinical Isolates of Enterococci with Low- and Medium-Level VanB-Type Vancomycin Resistance: a Multicenter Study

    PubMed Central

    Giske, Christian G.; Haldorsen, Bjørg; Matuschek, Erika; Schønning, Kristian; Leegaard, Truls M.; Kahlmeter, Gunnar

    2014-01-01

    Different antimicrobial susceptibility testing methods to detect low-level vancomycin resistance in enterococci were evaluated in a Scandinavian multicenter study (n = 28). A phenotypically and genotypically well-characterized diverse collection of Enterococcus faecalis (n = 12) and Enterococcus faecium (n = 18) strains with and without nonsusceptibility to vancomycin was examined blindly in Danish (n = 5), Norwegian (n = 13), and Swedish (n = 10) laboratories using the EUCAST disk diffusion method (n = 28) and the CLSI agar screen (n = 18) or the Vitek 2 system (bioMérieux) (n = 5). The EUCAST disk diffusion method (very major error [VME] rate, 7.0%; sensitivity, 0.93; major error [ME] rate, 2.4%; specificity, 0.98) and CLSI agar screen (VME rate, 6.6%; sensitivity, 0.93; ME rate, 5.6%; specificity, 0.94) performed significantly better (P = 0.02) than the Vitek 2 system (VME rate, 13%; sensitivity, 0.87; ME rate, 0%; specificity, 1). The performance of the EUCAST disk diffusion method was challenged by differences in vancomycin inhibition zone sizes as well as the experience of the personnel in interpreting fuzzy zone edges as an indication of vancomycin resistance. Laboratories using Oxoid agar (P < 0.0001) or Merck Mueller-Hinton (MH) agar (P = 0.027) for the disk diffusion assay performed significantly better than did laboratories using BBL MH II medium. Laboratories using Difco brain heart infusion (BHI) agar for the CLSI agar screen performed significantly better (P = 0.017) than did those using Oxoid BHI agar. In conclusion, both the EUCAST disk diffusion and CLSI agar screening methods performed acceptably (sensitivity, 0.93; specificity, 0.94 to 0.98) in the detection of VanB-type vancomycin-resistant enterococci with low-level resistance. Importantly, use of the CLSI agar screen requires careful monitoring of the vancomycin concentration in the plates. Moreover, disk diffusion methodology requires that personnel be trained in interpreting zone edges. PMID:24599985

  8. Modeling screening, prevention, and delaying of Alzheimer's disease: an early-stage decision analytic model

    PubMed Central

    2010-01-01

    Background Alzheimer's Disease (AD) affects a growing proportion of the population each year. Novel therapies on the horizon may slow the progress of AD symptoms and avoid cases altogether. Initiating treatment for the underlying pathology of AD would ideally be based on biomarker screening tools identifying pre-symptomatic individuals. Early-stage modeling provides estimates of potential outcomes and informs policy development. Methods A time-to-event (TTE) simulation provided estimates of screening asymptomatic patients in the general population age ≥55 and treatment impact on the number of patients reaching AD. Patients were followed from AD screen until all-cause death. Baseline sensitivity and specificity were 0.87 and 0.78, with treatment on positive screen. Treatment slowed progression by 50%. Events were scheduled using literature-based age-dependent incidences of AD and death. Results The base case results indicated increased AD free years (AD-FYs) through delays in onset and a reduction of 20 AD cases per 1000 screened individuals. Patients completely avoiding AD accounted for 61% of the incremental AD-FYs gained. Total years of treatment per 1000 screened patients was 2,611. The number-needed-to-screen was 51 and the number-needed-to-treat was 12 to avoid one case of AD. One-way sensitivity analysis indicated that duration of screening sensitivity and rescreen interval impact AD-FYs the most. A two-way sensitivity analysis found that for a test with an extended duration of sensitivity (15 years) the number of AD cases avoided was 6,000-7,000 cases for a test with higher sensitivity and specificity (0.90,0.90). Conclusions This study yielded valuable parameter range estimates at an early stage in the study of screening for AD. Analysis identified duration of screening sensitivity as a key variable that may be unavailable from clinical trials. PMID:20433705

  9. Sensitivity and specificity of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium: A single-center study in Japan.

    PubMed

    Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun

    2016-01-01

    To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Convenient, Sensitive and High-Throughput Method for Screening Botanic Origin

    NASA Astrophysics Data System (ADS)

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-01

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  11. Methicillin-Resistant Staphylococcus aureus: Comparison of Susceptibility Testing Methods and Analysis of mecA-Positive Susceptible Strains

    PubMed Central

    Sakoulas, George; Gold, Howard S.; Venkataraman, Lata; DeGirolami, Paola C.; Eliopoulos, George M.; Qian, Qinfang

    2001-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is responsible for an increasing number of serious nosocomial and community-acquired infections. Phenotypic heterogeneous drug resistance (heteroresistance) to antistaphylococcal beta-lactams affects the results of susceptibility testing. The present study compared the MRSA-Screen latex agglutination test (Denka Seiken Co., Ltd., Tokyo, Japan) for detection of PBP 2a with agar dilution, the VITEK-1 and VITEK-2 systems (bioMérieux, St. Louis, Mo.), and the oxacillin agar screen test for detection of MRSA, with PCR for the mecA gene used as the “gold standard” assay. Analysis of 107 methicillin-susceptible S. aureus (MSSA) isolates and 203 MRSA isolates revealed that the MRSA-Screen latex agglutination test is superior to any single phenotype-based susceptibility testing method, with a sensitivity of 100% and a specificity of 99.1%. Only one isolate that lacked mecA was weakly positive by the MRSA-Screen latex agglutination test. This isolate was phenotypically susceptible to oxacillin and did not contain the mecA gene by Southern blot hybridization. The oxacillin agar screen test, the VITEK-1 system, the VITEK-2 system, and agar dilution showed sensitivities of 99.0, 99.0, 99.5, and 99%, respectively, and specificities of 98.1, 100, 97.2, and 100%, respectively. The differences in sensitivity or specificity were not statistically significant. Oxacillin bactericidal assays showed that mecA- and PBP 2a-positive S. aureus isolates that are susceptible to antistaphylococcal beta-lactams by conventional methods are functionally resistant to oxacillin. We conclude that the accuracy of the MRSA-Screen latex agglutination method for detection of PBP 2a approaches the accuracy of PCR and is more accurate than any susceptibility testing method used alone for the detection of MRSA. PMID:11682512

  12. Interval cancers in a guaiac-based colorectal cancer screening programme: Consequences on sensitivity.

    PubMed

    Blom, Johannes; Törnberg, Sven

    2017-09-01

    Objective To evaluate interval cancers in the population-based colorectal cancer screening programme of Stockholm/Gotland, Sweden. Methods From 2008, individuals aged 60-69 were invited to colorectal cancer screening using biennial guaiac-based faecal occult blood test (Hemoccult®). Interval cancers, defined as colorectal cancer among participants not diagnosed by the screening programme but registered in the Swedish cancer register, were evaluated by cross-checking the screening histories for all cancers in the region 2008-2012. Results Of 203,848 individuals from nine different birth cohorts who participated (∼60%), 4530 (2.2%) tested positive. All invited individuals were followed up for 24 months after invitation. The cancer register reported 557 colorectal cancer, 219 (39.3%) screen-detected cancers and 338 (60.7%) interval cancers, generating both test- and episode sensitivities of approximately 40% and an interval cancer-rate of 17.1/10,000 tests. Among individuals with positive tests without colorectal cancer diagnosed at work-up colonoscopy, 37 interval cancers (10.9%) occurred. There was statistically significant lower sensitivity in women, ranging 22.4-32.2%, compared with 43.2-52.0% in men. Age-group and tumour location were not strongly correlated to screen-detected cancer rates. The programme sensitivity increased by year (20.3-25.0%), with successively more colorectal cancers diagnosed within the expanding programme (11.6-16.2%). Conclusion Interval cancer is a quality indicator of a screening programme. As the interval cancer-rate determined in a well-organized population-based screening programme was actually higher than the screen-detected cancer rate, a change to a more sensitive screening test is indicated. The lower screen-detected cancers among women, and compliance and quality of work-up colonoscopies also need attention.

  13. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    PubMed Central

    Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812

  14. SCIENTIFIC AND TECHNOLOGICAL SUPPORT ON IN VITRO ASSAYS FOR THE AGENCY'S ENDOCRINE DISRUPTOR SCREENING PROGRAM

    EPA Science Inventory

    In response to the 1996 legislative mandate for an endocrine screening and testing program, we are helping develop, standardize and validate relatively sensitive, robust and relatively simple methods for in vitro screening of chemicals that affect estrogen, and androgen function ...

  15. Pooled analysis of the accuracy of five cervical cancer screening tests assessed in eleven studies in Africa and India.

    PubMed

    Arbyn, Marc; Sankaranarayanan, Rengaswamy; Muwonge, Richard; Keita, Namory; Dolo, Amadou; Mbalawa, Charles Gombe; Nouhou, Hassan; Sakande, Boblewende; Wesley, Ramani; Somanathan, Thara; Sharma, Anjali; Shastri, Surendra; Basu, Parthasarathy

    2008-07-01

    Cervical cancer is the main cancer among women in sub-Saharan Africa, India and other parts of the developing world. Evaluation of screening performance of effective, feasible and affordable early detection and management methods is a public health priority. Five screening methods, naked eye visual inspection of the cervix uteri after application of diluted acetic acid (VIA), or Lugol's iodine (VILI) or with a magnifying device (VIAM), the Pap smear and human papillomavirus testing with the high-risk probe of the Hybrid Capture-2 assay (HC2), were evaluated in 11 studies in India and Africa. More than 58,000 women, aged 25-64 years, were tested with 2-5 screening tests and outcome verification was done on all women independent of the screen test results. The outcome was presence or absence of cervical intraepithelial neoplasia (CIN) of different degrees or invasive cervical cancer. Verification was based on colposcopy and histological interpretation of colposcopy-directed biopsies. Negative colposcopy was accepted as a truly negative outcome. VIA showed a sensitivity of 79% (95% CI 73-85%) and 83% (95% CI 77-89%), and a specificity of 85% (95% CI 81-89%) and 84% (95% CI 80-88%) for the outcomes CIN2+ or CIN3+, respectively. VILI was on average 10% more sensitive and equally specific. VIAM showed similar results as VIA. The Pap smear showed lowest sensitivity, even at the lowest cutoff of atypical squamous cells of undetermined significance (57%; 95% CI 38-76%) for CIN2+ but the specificity was rather high (93%; 95% CI 89-97%). The HC2-assay showed a sensitivity for CIN2+ of 62% (95% CI 56-68%) and a specificity of 94% (95% CI 92-95%). Substantial interstudy variation was observed in the accuracy of the visual screening methods. Accuracy of visual methods and cytology increased over time, whereas performance of HC2 was constant. Results of visual tests and colposcopy were highly correlated. This study was the largest ever done that evaluates the cross-sectional accuracy of screening tests for cervical cancer precursors in developing countries. The merit of the study was that all screened subjects were submitted to confirmatory investigations avoiding to verification bias. A major finding was the consistently higher sensitivity but equal specificity of VILI compared with VIA. Nevertheless, some caution is warranted in the interpretation of observed accuracy measures, since a certain degree of gold standard misclassification cannot be excluded. Because of the correlation between visual screening tests and colposcopy and a certain degree of over-diagnosis of apparent CIN2+ by study pathologists, it is possible that both sensitivity and specificity of VIA and VILI were overestimated. Gold standard verification error could also explain the surprisingly low sensitivity of HC2, which contrasts with findings from other studies. (c) 2008 Wiley-Liss, Inc.

  16. Ascertainment and verification of end-stage renal disease and end-stage liver disease in the north american AIDS cohort collaboration on research and design.

    PubMed

    Kitahata, Mari M; Drozd, Daniel R; Crane, Heidi M; Van Rompaey, Stephen E; Althoff, Keri N; Gange, Stephen J; Klein, Marina B; Lucas, Gregory M; Abraham, Alison G; Lo Re, Vincent; McReynolds, Justin; Lober, William B; Mendes, Adell; Modur, Sharada P; Jing, Yuezhou; Morton, Elizabeth J; Griffith, Margaret A; Freeman, Aimee M; Moore, Richard D

    2015-01-01

    The burden of HIV disease has shifted from traditional AIDS-defining illnesses to serious non-AIDS-defining comorbid conditions. Research aimed at improving HIV-related comorbid disease outcomes requires well-defined, verified clinical endpoints. We developed methods to ascertain and verify end-stage renal disease (ESRD) and end-stage liver disease (ESLD) and validated screening algorithms within the largest HIV cohort collaboration in North America (NA-ACCORD). Individuals who screened positive among all participants in twelve cohorts enrolled between January 1996 and December 2009 underwent medical record review to verify incident ESRD or ESLD using standardized protocols. We randomly sampled 6% of contributing cohorts to determine the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of ESLD and ESRD screening algorithms in a validation subcohort. Among 43,433 patients screened for ESRD, 822 screened positive of which 620 met clinical criteria for ESRD. The algorithm had 100% sensitivity, 99% specificity, 82% PPV, and 100% NPV for ESRD. Among 41,463 patients screened for ESLD, 2,024 screened positive of which 645 met diagnostic criteria for ESLD. The algorithm had 100% sensitivity, 95% specificity, 27% PPV, and 100% NPV for ESLD. Our methods proved robust for ascertainment of ESRD and ESLD in persons infected with HIV.

  17. Φ-score: A cell-to-cell phenotypic scoring method for sensitive and selective hit discovery in cell-based assays.

    PubMed

    Guyon, Laurent; Lajaunie, Christian; Fer, Frédéric; Bhajun, Ricky; Sulpice, Eric; Pinna, Guillaume; Campalans, Anna; Radicella, J Pablo; Rouillier, Philippe; Mary, Mélissa; Combe, Stéphanie; Obeid, Patricia; Vert, Jean-Philippe; Gidrol, Xavier

    2015-09-18

    Phenotypic screening monitors phenotypic changes induced by perturbations, including those generated by drugs or RNA interference. Currently-used methods for scoring screen hits have proven to be problematic, particularly when applied to physiologically relevant conditions such as low cell numbers or inefficient transfection. Here, we describe the Φ-score, which is a novel scoring method for the identification of phenotypic modifiers or hits in cell-based screens. Φ-score performance was assessed with simulations, a validation experiment and its application to gene identification in a large-scale RNAi screen. Using robust statistics and a variance model, we demonstrated that the Φ-score showed better sensitivity, selectivity and reproducibility compared to classical approaches. The improved performance of the Φ-score paves the way for cell-based screening of primary cells, which are often difficult to obtain from patients in sufficient numbers. We also describe a dedicated merging procedure to pool scores from small interfering RNAs targeting the same gene so as to provide improved visualization and hit selection.

  18. Φ-score: A cell-to-cell phenotypic scoring method for sensitive and selective hit discovery in cell-based assays

    PubMed Central

    Guyon, Laurent; Lajaunie, Christian; fer, Frédéric; bhajun, Ricky; sulpice, Eric; pinna, Guillaume; campalans, Anna; radicella, J. Pablo; rouillier, Philippe; mary, Mélissa; combe, Stéphanie; obeid, Patricia; vert, Jean-Philippe; gidrol, Xavier

    2015-01-01

    Phenotypic screening monitors phenotypic changes induced by perturbations, including those generated by drugs or RNA interference. Currently-used methods for scoring screen hits have proven to be problematic, particularly when applied to physiologically relevant conditions such as low cell numbers or inefficient transfection. Here, we describe the Φ-score, which is a novel scoring method for the identification of phenotypic modifiers or hits in cell-based screens. Φ-score performance was assessed with simulations, a validation experiment and its application to gene identification in a large-scale RNAi screen. Using robust statistics and a variance model, we demonstrated that the Φ-score showed better sensitivity, selectivity and reproducibility compared to classical approaches. The improved performance of the Φ-score paves the way for cell-based screening of primary cells, which are often difficult to obtain from patients in sufficient numbers. We also describe a dedicated merging procedure to pool scores from small interfering RNAs targeting the same gene so as to provide improved visualization and hit selection. PMID:26382112

  19. Are 2 Questions Enough to Screen for Depression and Anxiety in Patients With Chronic Low Back Pain?

    PubMed Central

    Lie, Stein Atle; Eriksen, Hege R.

    2014-01-01

    Study Design. Cross-sectional study. Objective. To examine the sensitivity of 2 single-item questions compared with 2 longer questionnaires for screening depression and anxiety among patients with chronic low back pain (CLBP). Summary of Background Data. Psychosocial factors are frequently identified as risk factors for developing CLBP and as predictors for treatment, and questionnaires are often used to screen for this. Shorter instruments may be easier to use in clinical practice settings. Methods. A total of 564 patients with 2 to 10 months of at least 50% sickness absence due to nonspecific low back pain were assessed for depression and anxiety with the Mini-International Neuropsychiatric Interview (MINI). Single-item questions for depression and anxiety from the Subjective Health Complaint Inventory and 2 longer questionnaires, the Hospital Anxiety and Depression Scale and Hopkins Symptom Checklist–25, were compared with MINI results, considered the “gold standard” in this study. Sensitivity and specificity of single-item and longer questionnaires and receiver operating characteristic curves were compared. Results. According to MINI, the prevalence of anxiety disorders was 12% whereas that of depressive disorders was 4%. The screening questions showed 95% sensitivity and 56% specificity for depressive disorders and 68% sensitivity and 85% specificity for anxiety disorders. The longer questionnaire, Hospital Anxiety and Depression Scale, showed 91% sensitivity and 85% specificity for depressive disorders and 58% sensitivity and 83% specificity for anxiety disorders. Hopkins Symptom Checklist–25 showed 86% sensitivity and 74% specificity for depressive disorders and 67% sensitivity and 87% specificity for anxiety disorders. For 3 of the anxiety disorders and 2 of the depressive disorders, a perfect sensitivity was found between the screening questions and MINI. Conclusions. A single-item screening question was sensitive for depression but less sensitive for anxiety. The screening questions further performed equal to 2 widely used questionnaires. Validation of these results in other populations and compared with other short-item screeners is needed. Level of Evidence: 3 PMID:24480946

  20. Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

    PubMed

    Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S

    2014-02-10

    Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.

  1. Sensitivity and specificity of Norwegian optometrists’ evaluation of diabetic retinopathy in single-field retinal images – a cross-sectional experimental study

    PubMed Central

    2013-01-01

    Background In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. Methods This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a “gold standard”, images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). Results The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. Conclusions The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education. PMID:23305337

  2. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  3. Screening for Human Immunodeficiency Virus, Hepatitis B Virus, Hepatitis C Virus, and Treponema pallidum by Blood Testing Using a Bio-Flash Technology-Based Algorithm before Gastrointestinal Endoscopy

    PubMed Central

    Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan

    2016-01-01

    Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum. The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. PMID:27707942

  4. Screening for Human Immunodeficiency Virus, Hepatitis B Virus, Hepatitis C Virus, and Treponema pallidum by Blood Testing Using a Bio-Flash Technology-Based Algorithm before Gastrointestinal Endoscopy.

    PubMed

    Jun, Zhou; Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan

    2016-12-01

    Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. Copyright © 2016 Jun et al.

  5. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    PubMed

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  6. Development and application of a general plasmid reference material for GMO screening.

    PubMed

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Fluorescence-based assay as a new screening tool for toxic chemicals

    PubMed Central

    Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey

    2016-01-01

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274

  8. Fluorescence-based assay as a new screening tool for toxic chemicals.

    PubMed

    Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey

    2016-09-22

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.

  9. Fluorescence-based assay as a new screening tool for toxic chemicals

    NASA Astrophysics Data System (ADS)

    Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey

    2016-09-01

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.

  10. A rapid screen for four corticosteroids in equine synovial fluid.

    PubMed

    Agrawal, Karan; Ebel, Joseph G; Bischoff, Karyn

    2014-06-01

    Most antidoping method development in the equine industry has been for plasma and urine, though there has been recent interest in the analysis of synovial fluid for evidence of doping by intra-articular corticosteroid injection. Published methods for corticosteroid analysis in synovial fluid are primarily singleplex methods, do not screen for all corticosteroids of interest and are not adequately sensitive. The purpose of this study is to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) screening method for the detection of four of the most common intra-articularly administered corticosteroids--betamethasone, methylprednisolone, methylprednisolone acetate and triamcinolone acetonide. Sample preparation consisted of protein precipitation followed by a basified liquid-liquid extraction. LC-MS-MS experiments consisted of a six-min isocratic separation using a Phenomenex Polar-RP stationary phase and a mobile phase consisting of 35% acetonitrile, 5 mM ammonium acetate and 0.1% formic acid in nanopure water. The detection system used was a triple quadrupole mass analyzer with thermospray ionization, and compounds were identified using selective reaction monitoring. The method was validated to the ISO/IEC 17025 standard, and real synovial fluid samples were analyzed to demonstrate the application of the method in an antidoping context. The method was highly selective for the four corticosteroids with limits of detection of 1-3 ng/mL. The extraction efficiency was 50-101%, and the matrix effects were 14-31%. These results indicate that the method is a rapid and sensitive screen for the four corticosteroids in equine synovial fluid, fit for purpose for equine antidoping assays.

  11. Convenient, sensitive and high-throughput method for screening botanic origin.

    PubMed

    Yuan, Yuan; Jiang, Chao; Liu, Libing; Yu, Shulin; Cui, Zhanhu; Chen, Min; Lin, Shufang; Wang, Shu; Huang, Luqi

    2014-06-23

    In this work, a rapid (within 4-5 h), sensitive and visible new method for assessing botanic origin is developed by combining loop-mediated isothermal amplification with cationic conjugated polymers. The two Chinese medicinal materials (Jin-Yin-Hua and Shan-Yin-Hua) with similar morphology and chemical composition were clearly distinguished by gene SNP genotyping assays. The identification of plant species in Patented Chinese drugs containing Lonicera buds is successfully performed using this detection system. The method is also robust enough to be used in high-throughput screening. This new method is very helpful to identify herbal materials, and is beneficial for detecting safety and quality of botanic products.

  12. COMPARISON OF IN VIVO AND IN VITRO CHEMICAL SCREENING ASSAYS FOR ESTROGEN-RESPONSIVE PROTEIN BIOMARKER EXPRESSION IN THE SHEEPSHEAD MINNOW (CYPRINODON VARIEGATUS)

    EPA Science Inventory

    Animal welfare concerns and the high cost associated with in vivo chemical screening methods have prompted efforts to develop highly specific and sensitive in vitro techniques to evaluate chemicals for endocrine activity. Diagnostic biomarkers developed using in vitro methods sho...

  13. Improving multi-objective reservoir operation optimization with sensitivity-informed problem decomposition

    NASA Astrophysics Data System (ADS)

    Chu, J. G.; Zhang, C.; Fu, G. T.; Li, Y.; Zhou, H. C.

    2015-04-01

    This study investigates the effectiveness of a sensitivity-informed method for multi-objective operation of reservoir systems, which uses global sensitivity analysis as a screening tool to reduce the computational demands. Sobol's method is used to screen insensitive decision variables and guide the formulation of the optimization problems with a significantly reduced number of decision variables. This sensitivity-informed problem decomposition dramatically reduces the computational demands required for attaining high quality approximations of optimal tradeoff relationships between conflicting design objectives. The search results obtained from the reduced complexity multi-objective reservoir operation problems are then used to pre-condition the full search of the original optimization problem. In two case studies, the Dahuofang reservoir and the inter-basin multi-reservoir system in Liaoning province, China, sensitivity analysis results show that reservoir performance is strongly controlled by a small proportion of decision variables. Sensitivity-informed problem decomposition and pre-conditioning are evaluated in their ability to improve the efficiency and effectiveness of multi-objective evolutionary optimization. Overall, this study illustrates the efficiency and effectiveness of the sensitivity-informed method and the use of global sensitivity analysis to inform problem decomposition when solving the complex multi-objective reservoir operation problems.

  14. Teleoperated robotic sorting system

    DOEpatents

    Roos, Charles E.; Sommer, Jr., Edward J.; Parrish, Robert H.; Russell, James R.

    2008-06-24

    A method and apparatus are disclosed for classifying materials utilizing a computerized touch sensitive screen or other computerized pointing device for operator identification and electronic marking of spatial coordinates of materials to be extracted. An operator positioned at a computerized touch sensitive screen views electronic images of the mixture of materials to be sorted as they are conveyed past a sensor array which transmits sequences of images of the mixture either directly or through a computer to the touch sensitive display screen. The operator manually "touches" objects displayed on the screen to be extracted from the mixture thereby registering the spatial coordinates of the objects within the computer. The computer then tracks the registered objects as they are conveyed and directs automated devices including mechanical means such as air jets, robotic arms, or other mechanical diverters to extract the registered objects.

  15. Teleoperated robotic sorting system

    DOEpatents

    Roos, Charles E.; Sommer, Edward J.; Parrish, Robert H.; Russell, James R.

    2000-01-01

    A method and apparatus are disclosed for classifying materials utilizing a computerized touch sensitive screen or other computerized pointing device for operator identification and electronic marking of spatial coordinates of materials to be extracted. An operator positioned at a computerized touch sensitive screen views electronic images of the mixture of materials to be sorted as they are conveyed past a sensor array which transmits sequences of images of the mixture either directly or through a computer to the touch sensitive display screen. The operator manually "touches" objects displayed on the screen to be extracted from the mixture thereby registering the spatial coordinates of the objects within the computer. The computer then tracks the registered objects as they are conveyed and directs automated devices including mechanical means such as air jets, robotic arms, or other mechanical diverters to extract the registered objects.

  16. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment

    PubMed Central

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-01-01

    Digital PCR has developed rapidly since it was first reported in the 1990s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products. PMID:26239916

  17. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    PubMed

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  18. Sensitivity analysis and nonlinearity assessment of steam cracking furnace process

    NASA Astrophysics Data System (ADS)

    Rosli, M. N.; Sudibyo, Aziz, N.

    2017-11-01

    In this paper, sensitivity analysis and nonlinearity assessment of cracking furnace process are presented. For the sensitivity analysis, the fractional factorial design method is employed as a method to analyze the effect of input parameters, which consist of four manipulated variables and two disturbance variables, to the output variables and to identify the interaction between each parameter. The result of the factorial design method is used as a screening method to reduce the number of parameters, and subsequently, reducing the complexity of the model. It shows that out of six input parameters, four parameters are significant. After the screening is completed, step test is performed on the significant input parameters to assess the degree of nonlinearity of the system. The result shows that the system is highly nonlinear with respect to changes in an air-to-fuel ratio (AFR) and feed composition.

  19. Comparison of four methods to assess colostral IgG concentration in dairy cows.

    PubMed

    Chigerwe, Munashe; Tyler, Jeff W; Middleton, John R; Spain, James N; Dill, Jeffrey S; Steevens, Barry J

    2008-09-01

    To determine sensitivity and specificity of 4 methods to assess colostral IgG concentration in dairy cows and determine the optimal cutpoint for each method. Cross-sectional study. 160 Holstein dairy cows. 171 composite colostrum samples collected within 2 hours after parturition were used in the study. Test methods used to estimate colostral IgG concentration consisted of weight of the first milking, 2 hydrometers, and an electronic refractometer. Results of the test methods were compared with colostral IgG concentration determined by means of radial immunodiffusion. For each method, sensitivity and specificity for detecting colostral IgG concentration < 50 g/L were calculated across a range of potential cutpoints, and the optimal cutpoint for each test was selected to maximize sensitivity and specificity. At the optimal cutpoint for each method, sensitivity for weight of the first milking (0.42) was significantly lower than sensitivity for each of the other 3 methods (hydrometer 1, 0.75; hydrometer 2, 0.76; refractometer, 0.75), but no significant differences were identified among the other 3 methods with regard to sensitivity. Specificities at the optimal cutpoint were similar for all 4 methods. Results suggested that use of either hydrometer or the electronic refractometer was an acceptable method of screening colostrum for low IgG concentration; however, the manufacturer-defined scale for both hydrometers overestimated colostral IgG concentration. Use of weight of the first milking as a screening test to identify bovine colostrum with inadequate IgG concentration could not be justified because of the low sensitivity.

  20. Anthropometric methods for obesity screening in schoolchildren: the Ouro Preto Study.

    PubMed

    Cándido, A P C; Alosta, J P S; Oliveira, C T; Freitas, R N; Freitas, S N; Machado-Coelho, G L L

    2012-01-01

    Childhood obesity is increasing dramatically in last decades. To evaluate the usefulness of body mass index (BMI), skinfold thickness (ST), waist circumference (WC), and foot-to-foot bioelectrical impedance (BIA-FF) for screening for obesity in mixed-race population, using the tetrapolar bioelectrical impedance (BIA-T) technique as reference method. A cross-sectional-based population study was performed in the city of Ouro Preto, Brazil, in 2006. Schoolchildren aged 6-15 years (n = 788) was randomly selected according to age and sex stratified by the proportion of students in each schools of the city. Nonparametric receiver operating characteristic (ROC) analysis was used to define the sensitivity and specificity for each method studied using the tetrapolar method as reference. The BMI and the BIA-FF were the most suitable for adiposity screening in pre-pubertal and pubertal stages because they present a better balance between sensitivity and specificity, and smaller misclassification. For post-pubertal boys, the BF-ST-D was the best body fat assessment method. The results suggest that BIA-FF and BMI are choice methods for obesity screening in mixed population and that the method choice for body fat screening must be done according to sexual maturity of boys and girls. The present study demonstrates the need to perform studies in wider mixed-race population to determine anthropometric parameters and to examine the predictive ability of methods and cut-offs here elucidated in the development of obesity.

  1. Sensitivity and Specificity of a Five-Minute Cognitive Screening Test in Patients With Heart Failure.

    PubMed

    Cameron, Janette D; Gallagher, Robyn; Pressler, Susan J; McLennan, Skye N; Ski, Chantal F; Tofler, Geoffrey; Thompson, David R

    2016-02-01

    Cognitive impairment occurs in up to 80% of patients with heart failure (HF). The National Institute for Neurological Disorders and Stroke (NINDS) and the Canadian Stroke Network (CSN) recommend a 5-minute cognitive screening protocol that has yet to be psychometrically evaluated in HF populations. The aim of this study was to conduct a secondary analysis of the sensitivity and specificity of the NINDS-CSN brief cognitive screening protocol in HF patients. The Montreal Cognitive Assessment (MoCA) was administered to 221 HF patients. The NINDS-CSN screen comprises 3 MoCA items, with lower scores indicating poorer cognitive function. Receiver operator characteristic (ROC) curves were constructed, determining the sensitivity, specificity and appropriate cutoff scores of the NINDS-CSN screen. In an HF population aged 76 ± 12 years, 136 (62%) were characterized with cognitive impairment (MoCA <26). Scores on the NINDS-CSN screen ranged from 3-11. The area under the receiver operating characteristic curve indicated good accuracy in screening for cognitive impairment (0.88; P < .01; 95% CI 0.83-0.92). A cutoff score of ≤9 provided 89% sensitivity and 71% specificity. The NINDS-CSN protocol offers clinicians a feasible telephone method to screen for cognitive impairment in patients with HF. Future studies should include a neuropsychologic battery to more comprehensively examine the diagnostic accuracy of brief cognitive screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. SensiScreen® KRAS exon 2-sensitive simplex and multiplex real-time PCR-based assays for detection of KRAS exon 2 mutations

    PubMed Central

    Guldmann-Christensen, Mariann; Hauge Kyneb, Majbritt; Voogd, Kirsten; Andersen, Christina; Epistolio, Samantha; Merlo, Elisabetta; Yding Wolff, Tine; Hamilton-Dutoit, Stephen; Lorenzen, Jan; Christensen, Ulf Bech

    2017-01-01

    Activating mutations in codon 12 and codon 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) gene are implicated in the development of several human cancer types and influence their clinical evaluation, treatment and prognosis. Numerous different methods for KRAS genotyping are currently available displaying a wide range of sensitivities, time to answer and requirements for laboratory equipment and user skills. Here we present SensiScreen® KRAS exon 2 simplex and multiplex CE IVD assays, that use a novel real-time PCR-based method for KRAS mutation detection based on PentaBase’s proprietary DNA analogue technology and designed to work on standard real-time PCR instruments. By means of the included BaseBlocker™ technology, we show that SensiScreen® specifically amplifies the mutated alleles of interest with no or highly subdued amplification of the wild type allele. Furthermore, serial dilutions of mutant DNA in a wild type background demonstrate that all SensiScreen® assays display a limit of detection that falls within the range of 0.25–1%. Finally, in three different colorectal cancer patient populations, SensiScreen® assays confirmed the KRAS genotype previously determined by commonly used methods for KRAS mutation testing, and notably, in two of the populations, SensiScreen® identified additional mutant positive cases not detected by common methods. PMID:28636636

  3. The influence of film-screen color sensitivity and type of measurement device on kVp measurements.

    PubMed

    Lam, R W; Price, S C

    1989-01-01

    Three methods for evaluating radiographic kVp were studied: the Wisconsin Test Cassette, the Noninvasive Evaluator of Radiation Outputs (NERO), and the Dynalyzer. The Dynalyzer kVp readings were the highest and were followed by NERO and cassette readings in descending order. By film type, the cassette readings ranged from Kodak OG (green sensitive), TMG (green sensitive), XK (blue sensitive), and XRP (blue sensitive) in descending order. The results show that there is significant variation between the methods.

  4. [Comparative sensitivity of different solid-phase immunoassays for detecting HBsAg and anti-HCV in blood].

    PubMed

    León, P; López, J A; Domingo, C J; Echevarría, J M

    1992-10-01

    The sensitivities of seven methods of enzyme-immunoassay for HBsAg detection, as well as of twelve immunoassays for detecting antibody to HCV, were compared, in an attempt to evaluate the need for an official technical validation of such methods prior to its commercialization in Spain. Significant differences were seen for the sensitivities of these methods, which may influence the proficiency of blood bank screening for HBsAg and anti-HCV for preventing cases of post-transfusional viral hepatitis. As a conclusion, it is recommended to establish legal regulations for pre-marketing validation of such assays in Spain, as well as to take the results obtained in these evaluation studies as the basis for selecting those tests which may be more convenient for screening purposes at the blood banks.

  5. [Screening for cancer - economic consideration and cost-effectiveness].

    PubMed

    Kjellberg, Jakob

    2014-06-09

    Cost-effectiveness analysis has become an accepted method to evaluate medical technology and allocate scarce health-care resources. Published decision analyses show that screening for cancer in general is cost-effective. However, cost-effectiveness analyses are only as good as the clinical data and the results are sensitive to the chosen methods and perspective of the analysis.

  6. Computationally inexpensive identification of noninformative model parameters by sequential screening

    NASA Astrophysics Data System (ADS)

    Cuntz, Matthias; Mai, Juliane; Zink, Matthias; Thober, Stephan; Kumar, Rohini; Schäfer, David; Schrön, Martin; Craven, John; Rakovec, Oldrich; Spieler, Diana; Prykhodko, Vladyslav; Dalmasso, Giovanni; Musuuza, Jude; Langenberg, Ben; Attinger, Sabine; Samaniego, Luis

    2015-08-01

    Environmental models tend to require increasing computational time and resources as physical process descriptions are improved or new descriptions are incorporated. Many-query applications such as sensitivity analysis or model calibration usually require a large number of model evaluations leading to high computational demand. This often limits the feasibility of rigorous analyses. Here we present a fully automated sequential screening method that selects only informative parameters for a given model output. The method requires a number of model evaluations that is approximately 10 times the number of model parameters. It was tested using the mesoscale hydrologic model mHM in three hydrologically unique European river catchments. It identified around 20 informative parameters out of 52, with different informative parameters in each catchment. The screening method was evaluated with subsequent analyses using all 52 as well as only the informative parameters. Subsequent Sobol's global sensitivity analysis led to almost identical results yet required 40% fewer model evaluations after screening. mHM was calibrated with all and with only informative parameters in the three catchments. Model performances for daily discharge were equally high in both cases with Nash-Sutcliffe efficiencies above 0.82. Calibration using only the informative parameters needed just one third of the number of model evaluations. The universality of the sequential screening method was demonstrated using several general test functions from the literature. We therefore recommend the use of the computationally inexpensive sequential screening method prior to rigorous analyses on complex environmental models.

  7. Computationally inexpensive identification of noninformative model parameters by sequential screening

    NASA Astrophysics Data System (ADS)

    Mai, Juliane; Cuntz, Matthias; Zink, Matthias; Thober, Stephan; Kumar, Rohini; Schäfer, David; Schrön, Martin; Craven, John; Rakovec, Oldrich; Spieler, Diana; Prykhodko, Vladyslav; Dalmasso, Giovanni; Musuuza, Jude; Langenberg, Ben; Attinger, Sabine; Samaniego, Luis

    2016-04-01

    Environmental models tend to require increasing computational time and resources as physical process descriptions are improved or new descriptions are incorporated. Many-query applications such as sensitivity analysis or model calibration usually require a large number of model evaluations leading to high computational demand. This often limits the feasibility of rigorous analyses. Here we present a fully automated sequential screening method that selects only informative parameters for a given model output. The method requires a number of model evaluations that is approximately 10 times the number of model parameters. It was tested using the mesoscale hydrologic model mHM in three hydrologically unique European river catchments. It identified around 20 informative parameters out of 52, with different informative parameters in each catchment. The screening method was evaluated with subsequent analyses using all 52 as well as only the informative parameters. Subsequent Sobol's global sensitivity analysis led to almost identical results yet required 40% fewer model evaluations after screening. mHM was calibrated with all and with only informative parameters in the three catchments. Model performances for daily discharge were equally high in both cases with Nash-Sutcliffe efficiencies above 0.82. Calibration using only the informative parameters needed just one third of the number of model evaluations. The universality of the sequential screening method was demonstrated using several general test functions from the literature. We therefore recommend the use of the computationally inexpensive sequential screening method prior to rigorous analyses on complex environmental models.

  8. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks

    PubMed Central

    Arampatzis, Georgios; Katsoulakis, Markos A.; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in “sloppy” systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the number of the sensitive parameters. PMID:26161544

  9. Impact of transition from microscopy to molecular screening for detection of intestinal protozoa in Dutch patients.

    PubMed

    Svraka-Latifovic, S; Bouter, S; Naus, H; Bakker, L J; Timmerman, C P; Dorigo-Zetsma, J W

    2014-11-01

    Detection of intestinal protozoa by PCR methods has been described as being sensitive and specific, and as improving the diagnostic yield. Here we present the outcome of the transition from microscopy to molecular screening for detection of a select group of intestinal protozoa in faeces in our laboratory. Introduction of molecular screening for intestinal protozoa resulted in higher sensitivity, reduced hands-on-time, reduced time-to-results, leading to improved diagnostic efficiency. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  10. Comparison of methods for in-house screening of HLA-B*57:01 to prevent abacavir hypersensitivity in HIV-1 care.

    PubMed

    De Spiegelaere, Ward; Philippé, Jan; Vervisch, Karen; Verhofstede, Chris; Malatinkova, Eva; Kiselinova, Maja; Trypsteen, Wim; Bonczkowski, Pawel; Vogelaers, Dirk; Callens, Steven; Ruelle, Jean; Kabeya, Kabamba; De Wit, Stephane; Van Acker, Petra; Van Sandt, Vicky; Emonds, Marie-Paule; Coucke, Paul; Sermijn, Erica; Vandekerckhove, Linos

    2015-01-01

    Abacavir is a nucleoside reverse transcriptase inhibitor used as part of combination antiretroviral therapy in HIV-1-infected patients. Because this drug can cause a hypersensitivity reaction that is correlated with the presence of the HLA-B*57:01 allotype, screening for the presence of HLA-B*57:01 is recommended before abacavir initiation. Different genetic assays have been developed for HLA-B*57:01 screening, each with specific sensitivity, turnaround time and assay costs. Here, a new real-time PCR (qPCR) based analysis is described and compared to sequence specific primer PCR with capillary electrophoresis (SSP PCR CE) on 149 patient-derived samples, using sequence specific oligonucleotide hybridization combined with high resolution SSP PCR as gold standard. In addition to these PCR based methods, a complementary approach was developed using flow cytometry with an HLA-B17 specific monoclonal antibody as a pre-screening assay to diminish the number of samples for genetic testing. All three assays had a maximum sensitivity of >99. However, differences in specificity were recorded, i.e. 84.3%, 97.2% and >99% for flow cytometry, qPCR and SSP PCR CE respectively. Our data indicate that the most specific and sensitive of the compared methods is the SSP PCR CE. Flow cytometry pre-screening can substantially decrease the number of genetic tests for HLA-B*57:01 typing in a clinical setting.

  11. Development and Validation of a P-35S, T-nos, T-35S and P-FMV Tetraplex Real-time PCR Screening Method to Detect Regulatory Genes of Genetically Modified Organisms in Food.

    PubMed

    Eugster, Albert; Murmann, Petra; Kaenzig, Andre; Breitenmoser, Alda

    2014-10-01

    In routine analysis screening methods based on real-time PCR (polymerase chain reaction) are most commonly used for the detection of genetically modified (GM) plant material in food and feed. Screening tests are based on sequences frequently used for GM development, allowing the detection of a large number of GMOs (genetically modified organisms). Here, we describe the development and validation of a tetraplex real-time PCR screening assay comprising detection systems for the regulatory genes Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens nos terminator, Cauliflower Mosaic Virus 35S terminator and Figwort Mosaic Virus 34S promoter. Three of the four primer and probe combinations have already been published elsewhere, whereas primers and probe for the 35S terminator have been developed in-house. Adjustment of primer and probe concentrations revealed a high PCR sensitivity with insignificant physical cross-talk between the four detection channels. The sensitivity of each PCR-system is sufficient to detect a GMO concentration as low as 0.05% of the containing respective element. The specificity of the described tetraplex is high when tested on DNA from GM maize, soy, rapeseed and tomato. We also demonstrate the robustness of the system by inter-laboratory tests. In conclusion, this method provides a sensitive and reliable screening procedure for the detection of the most frequently used regulatory elements present in GM crops either authorised or unauthorised for food.

  12. Pulse Oximetry and Auscultation for Congenital Heart Disease Detection.

    PubMed

    Hu, Xiao-Jing; Ma, Xiao-Jing; Zhao, Qu-Ming; Yan, Wei-Li; Ge, Xiao-Ling; Jia, Bing; Liu, Fang; Wu, Lin; Ye, Ming; Liang, Xue-Cun; Zhang, Jing; Gao, Yan; Zhai, Xiao-Wen; Huang, Guo-Ying

    2017-10-01

    Pulse oximetry (POX) has been confirmed as a specific screening modality for critical congenital heart disease (CCHD), with moderate sensitivity. However, POX is not able to detect most serious and critical cardiac lesions (major congenital heart disease [CHD]) without hypoxemia. In this study, we investigated the accuracy and feasibility of the addition of cardiac auscultation to POX as a screening method for asymptomatic major CHD. A multicenter prospective observational screening study was conducted at 15 hospitals in Shanghai between July 1, 2012, and December 31, 2014. Newborns with either an abnormal POX or cardiac auscultation were defined as screen positive. All screen-positive newborns underwent further echocardiography. False-negative results were identified by clinical follow-up, parents' feedback, and telephone review. We assessed the accuracy of POX plus cardiac auscultation for the detection of major CHD. CHD screening was completed in all 15 hospitals, with a screening rate of 94.0% to 99.8%. In total, 167 190 consecutive asymptomatic newborn infants were screened, of which 203 had major CHD (44 critical and 159 serious). The sensitivity of POX plus cardiac auscultation was 95.5% (95% confidence interval 84.9%-98.7%) for CCHD and 92.1% (95% confidence interval 87.7%-95.1%) for major CHD. The false-positive rate was 1.2% for detecting CCHD and 1.1% for detecting major CHD. In our current study, we show that using POX plus cardiac auscultation significantly improved the detection rate of major CHD in the early neonatal stage, with high sensitivity and a reasonable false-positive rate. It provides strong evidence and a reliable method for neonatal CHD screening. Copyright © 2017 by the American Academy of Pediatrics.

  13. Assessment of circulating copy number variant detection for cancer screening.

    PubMed

    Molparia, Bhuvan; Nichani, Eshaan; Torkamani, Ali

    2017-01-01

    Current high-sensitivity cancer screening methods, largely utilizing correlative biomarkers, suffer from false positive rates that lead to unnecessary medical procedures and debatable public health benefit overall. Detection of circulating tumor DNA (ctDNA), a causal biomarker, has the potential to revolutionize cancer screening. Thus far, the majority of ctDNA studies have focused on detection of tumor-specific point mutations after cancer diagnosis for the purpose of post-treatment surveillance. However, ctDNA point mutation detection methods developed to date likely lack either the scope or analytical sensitivity necessary to be useful for cancer screening, due to the low (<1%) ctDNA fraction derived from early stage tumors. On the other hand, tumor-derived copy number variant (CNV) detection is hypothetically a superior means of ctDNA-based cancer screening for many tumor types, given that, relative to point mutations, each individual tumor CNV contributes a much larger number of ctDNA fragments to the overall pool of circulating free DNA (cfDNA). A small number of studies have demonstrated the potential of ctDNA CNV-based screening in select cancer types. Here we perform an in silico assessment of the potential for ctDNA CNV-based cancer screening across many common cancers, and suggest ctDNA CNV detection shows promise as a broad cancer screening methodology.

  14. Automated detection of neovascularization for proliferative diabetic retinopathy screening.

    PubMed

    Roychowdhury, Sohini; Koozekanani, Dara D; Parhi, Keshab K

    2016-08-01

    Neovascularization is the primary manifestation of proliferative diabetic retinopathy (PDR) that can lead to acquired blindness. This paper presents a novel method that classifies neovascularizations in the 1-optic disc (OD) diameter region (NVD) and elsewhere (NVE) separately to achieve low false positive rates of neovascularization classification. First, the OD region and blood vessels are extracted. Next, the major blood vessel segments in the 1-OD diameter region are classified for NVD, and minor blood vessel segments elsewhere are classified for NVE. For NVD and NVE classifications, optimal region-based feature sets of 10 and 6 features, respectively, are used. The proposed method achieves classification sensitivity, specificity and accuracy for NVD and NVE of 74%, 98.2%, 87.6%, and 61%, 97.5%, 92.1%, respectively. Also, the proposed method achieves 86.4% sensitivity and 76% specificity for screening images with PDR from public and local data sets. Thus, the proposed NVD and NVE detection methods can play a key role in automated screening and prioritization of patients with diabetic retinopathy.

  15. Improving detection of HIV-associated cognitive impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery

    PubMed Central

    de Almeida, Sergio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea Elisa; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K.; Ellis, Ronald J.

    2016-01-01

    Objectives The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia (HAD), but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. Methods 108 participants (including 60 HIV-infected persons), completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible three-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Results Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75% respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared to the gold standard NP battery, were Trail Making Test A, WAIS-III Digit Symbol (DS) and HVLT-R Total Recall (sensitivity 91%, specificity 96%), and DS, BVMT-R Total Recall and Grooved Pegboard Test-Dominant Hand (sensitivity 94%, specificity 91%). Conclusions Both test combinations can be administered in under 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination. PMID:27828876

  16. A rapid, efficient and sensitive plate assay for detection and screening of l-asparaginase-producing microorganisms.

    PubMed

    Mahajan, Richi V; Saran, Saurabh; Saxena, Rajendra K; Srivastava, Ayush K

    2013-04-01

    l-Asparaginase-producing microbes are conventionally screened on phenol red l-asparagine-containing plates. However, sometimes the contrast of the zone obtained (between yellow and pink) is not very sharp and distinct. In the present investigation, an improved method for screening of the microorganisms producing extracellular l-asparaginase is reported wherein bromothymol blue (BTB) is incorporated as pH indicator in l-asparagine-containing medium instead of phenol red. Plates containing BTB at acidic pH are yellow and turn dark blue at alkaline pH. Thus, a dense dark blue zone is formed around microbial colonies producing l-asparaginase, differentiating between enzyme producers and non-producers. The present method is more sensitive and accurate than the conventional method for screening of both fungi and bacteria producing extracellular l-asparaginase. Furthermore, BTB gives a transient green colour at neutral pH (7.0) and dark blue colour at higher pH 8.0-9.0, indicating the potency of the microorganism for l-asparaginase production. © 2013 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  17. Screening markers for chronic atrophic gastritis in Chiapas, Mexico.

    PubMed

    Ley, C; Mohar, A; Guarner, J; Herrera-Goepfert, R; Figueroa, L S; Halperin, D; Parsonnet, J

    2001-02-01

    Intestinal-type gastric adenocarcinomas usually are preceded by chronic atrophic gastritis. Studies of gastric cancer prevention often rely on identification of this condition. In a clinical trial, we sought to determine the best serological screening method for chronic atrophic gastritis and compared our findings to the published literature. Test characteristics of potential screening tests (antibodies to Helicobacter pyloni or CagA, elevated gastrin, low pepsinogen, increased age) alone or in combination were examined among consecutive subjects enrolled in a study of H. pylori and preneoplastic gastric lesions in Chiapas, Mexico; 70% had chronic atrophic gastritis. English-language articles concerning screening for chronic atrophic gastritis were also reviewed. Sensitivity for chronic atrophic gastritis was highest for antibodies to H. pylori (92%) or CagA, or gastrin levels >25 ng/l (both 83%). Specificity, however, was low for these tests (18, 41, and 22%, respectively). Pepsinogen levels were highly specific but insensitive markers of chronic atrophic gastritis (for pepsinogen I <25 microg/l, sensitivity was 6% and specificity was 100%; for pepsinogen I:pepsinogen II ratio <2.5, sensitivity was 14% and specificity was 96%). Combinations of markers did not improve test characteristics. Screening test characteristics from the literature varied widely and did not consistently identify a good screening strategy. In this study, CagA antibodies alone had the best combination of test characteristics for chronic atrophic gastritis screening. However, no screening test was both highly sensitive and highly specific for chronic atrophic gastritis.

  18. Effect of Antiretroviral Therapy on the Diagnostic Accuracy of Symptom Screening for Intensified Tuberculosis Case Finding in a South African HIV Clinic

    PubMed Central

    Rangaka, Molebogeng X.; Wilkinson, Robert J.; Glynn, Judith R.; Boulle, Andrew; van Cutsem, Gilles; Goliath, Rene; Mathee, Shaheed; Maartens, Gary

    2012-01-01

    Background. Current symptom screening algorithms for intensified tuberculosis case finding or prior to isoniazid preventive therapy (IPT) in patients infected with human immunodeficiency virus (HIV) were derived from antiretroviral-naive cohorts. There is a need to validate screening algorithms in patients on antiretroviral therapy (ART). Methods. We performed cross-sectional evaluation of the diagnostic accuracy of symptom screening, including the World Health Organization (WHO) algorithm, to rule out tuberculosis in HIV-infected individuals pre-ART and on ART undergoing screening prior to IPT. Results. A total of 1429 participants, 54% on ART, had symptom screening and a sputum culture result available. Culture-positive tuberculosis was diagnosed in 126 patients (8.8%, 95% confidence interval [CI], 7.4%–10.4%). The WHO symptom screen in the on-ART compared with the pre-ART group had a lower sensitivity (23.8% vs 47.6%), but higher specificity (94.4% vs 79.8%). The effect of ART was independent of CD4+ count in multivariable analyses. The posttest probability of tuberculosis following a negative WHO screen was 8.9% (95% CI, 7.4%–10.8%) and 4.4% (95% CI, 3.7%–5.2%) for the pre-ART and on-ART groups, respectively. Addition of body mass index to the WHO screen significantly improved discriminatory ability in both ART groups, which was further improved by adding CD4 count and ART duration. Conclusions. The WHO symptom screen has poor sensitivity, especially among patients on ART, in a clinic where regular tuberculosis screening is practiced. Consequently, a significant proportion of individuals with tuberculosis would inadvertently be placed on isoniazid monotherapy despite high negative predictive values. Until more sensitive methods of ruling out tuberculosis are established, it would be prudent to do a sputum culture prior to IPT where this is feasible. PMID:22955441

  19. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda

    PubMed Central

    Brooker, Simon; Kabatereine, Narcis B.; Myatt, Mark; Stothard, J. Russell; Fenwick, Alan

    2007-01-01

    Summary Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalence ≥50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$ 218 vs. US$ 482 / high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence exceeds 50% in 75% of schools and for treatment costs of US$ 0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid, and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis. PMID:15960703

  20. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda.

    PubMed

    Brooker, Simon; Kabatereine, Narcis B; Myatt, Mark; Russell Stothard, J; Fenwick, Alan

    2005-07-01

    Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according to categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalences > or =50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$218 vs. US$482/high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence > or =50% in 75% of schools and for treatment costs of US$0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis.

  1. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    PubMed

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  2. Automatic detection of anomalies in screening mammograms

    PubMed Central

    2013-01-01

    Background Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%. PMID:24330643

  3. Quantitative digital image analysis of chromogenic assays for high throughput screening of alpha-amylase mutant libraries.

    PubMed

    Shankar, Manoharan; Priyadharshini, Ramachandran; Gunasekaran, Paramasamy

    2009-08-01

    An image analysis-based method for high throughput screening of an alpha-amylase mutant library using chromogenic assays was developed. Assays were performed in microplates and high resolution images of the assay plates were read using the Virtual Microplate Reader (VMR) script to quantify the concentration of the chromogen. This method is fast and sensitive in quantifying 0.025-0.3 mg starch/ml as well as 0.05-0.75 mg glucose/ml. It was also an effective screening method for improved alpha-amylase activity with a coefficient of variance of 18%.

  4. 454 next generation-sequencing outperforms allele-specific PCR, Sanger sequencing, and pyrosequencing for routine KRAS mutation analysis of formalin-fixed, paraffin-embedded samples

    PubMed Central

    Altimari, Annalisa; de Biase, Dario; De Maglio, Giovanna; Gruppioni, Elisa; Capizzi, Elisa; Degiovanni, Alessio; D’Errico, Antonia; Pession, Annalisa; Pizzolitto, Stefano; Fiorentino, Michelangelo; Tallini, Giovanni

    2013-01-01

    Detection of KRAS mutations in archival pathology samples is critical for therapeutic appropriateness of anti-EGFR monoclonal antibodies in colorectal cancer. We compared the sensitivity, specificity, and accuracy of Sanger sequencing, ARMS-Scorpion (TheraScreen®) real-time polymerase chain reaction (PCR), pyrosequencing, chip array hybridization, and 454 next-generation sequencing to assess KRAS codon 12 and 13 mutations in 60 nonconsecutive selected cases of colorectal cancer. Twenty of the 60 cases were detected as wild-type KRAS by all methods with 100% specificity. Among the 40 mutated cases, 13 were discrepant with at least one method. The sensitivity was 85%, 90%, 93%, and 92%, and the accuracy was 90%, 93%, 95%, and 95% for Sanger sequencing, TheraScreen real-time PCR, pyrosequencing, and chip array hybridization, respectively. The main limitation of Sanger sequencing was its low analytical sensitivity, whereas TheraScreen real-time PCR, pyrosequencing, and chip array hybridization showed higher sensitivity but suffered from the limitations of predesigned assays. Concordance between the methods was k = 0.79 for Sanger sequencing and k > 0.85 for the other techniques. Tumor cell enrichment correlated significantly with the abundance of KRAS-mutated deoxyribonucleic acid (DNA), evaluated as ΔCt for TheraScreen real-time PCR (P = 0.03), percentage of mutation for pyrosequencing (P = 0.001), ratio for chip array hybridization (P = 0.003), and percentage of mutation for 454 next-generation sequencing (P = 0.004). Also, 454 next-generation sequencing showed the best cross correlation for quantification of mutation abundance compared with all the other methods (P < 0.001). Our comparison showed the superiority of next-generation sequencing over the other techniques in terms of sensitivity and specificity. Next-generation sequencing will replace Sanger sequencing as the reference technique for diagnostic detection of KRAS mutation in archival tumor tissues. PMID:23950653

  5. Correlation analysis of two serum-specific immunoglobulin E test systems and skin-prick test in allergic rhinitis patients from northeast China.

    PubMed

    Jiang, Xiao-Dan; Li, Guang-Yu; Dong, Zhen; Zhu, Dong-Dong

    2011-01-01

    Skin-prick testing (SPT) is the most common screening method for allergy evaluation. The detection of serum-specific immunoglobulin E (sIgE) is also commonly used. The sensitivity and specificity of these testing methods may vary due to type of causative allergen and type of allergic manifestation. The purpose of this study was to evaluate the correlation between two methods of measuring sIgE (AllergyScreen [Mediwiss Analytic GmbH, Moers, Germany] and ImmunoCAP [Pharmacia, Uppsala, Sweden]) and SPT for the diagnosis of allergic rhinitis (AR). All 216 patients who were referred to the allergist for suspected AR from June to October 2009 had SPT and the two serological tests. One hundred fifty-eight patients had a positive clinical history and a related positive SPT. The SPT was used as reference standard, and we selected three allergens (Dermatophagoides pteronyssinus, mugwort, and ragweed), which were common in fall in northeast China, to analyze the correlation of the two serum tests and SPT. Compared with the SPT, the diagnostic indexes (accuracy, sensitivity and specificity) of the AllergyScreen system and the ImmunoCAP system were 0.819 versus 0.810, 0.780 versus 0.872, and 0.862 versus 0.741, respectively. The accuracy was similar between the two systems (p > 0.05). The ImmunoCAP system method had a higher sensitivity (p < 0.01). The AllergyScreen system had a higher specificity (p < 0.01). These data support that the AllergyScreen system and ImmunoCAP system can identify potentially significant allergens in the diagnosis of AR in patients from northeastern China.

  6. Performance of an automated electronic acute lung injury screening system in intensive care unit patients.

    PubMed

    Koenig, Helen C; Finkel, Barbara B; Khalsa, Satjeet S; Lanken, Paul N; Prasad, Meeta; Urbani, Richard; Fuchs, Barry D

    2011-01-01

    Lung protective ventilation reduces mortality in patients with acute lung injury, but underrecognition of acute lung injury has limited its use. We recently validated an automated electronic acute lung injury surveillance system in patients with major trauma in a single intensive care unit. In this study, we assessed the system's performance as a prospective acute lung injury screening tool in a diverse population of intensive care unit patients. Patients were screened prospectively for acute lung injury over 21 wks by the automated system and by an experienced research coordinator who manually screened subjects for enrollment in Acute Respiratory Distress Syndrome Clinical Trials Network (ARDSNet) trials. Performance of the automated system was assessed by comparing its results with the manual screening process. Discordant results were adjudicated blindly by two physician reviewers. In addition, a sensitivity analysis using a range of assumptions was conducted to better estimate the system's performance. The Hospital of the University of Pennsylvania, an academic medical center and ARDSNet center (1994-2006). Intubated patients in medical and surgical intensive care units. None. Of 1270 patients screened, 84 were identified with acute lung injury (incidence of 6.6%). The automated screening system had a sensitivity of 97.6% (95% confidence interval, 96.8-98.4%) and a specificity of 97.6% (95% confidence interval, 96.8-98.4%). The manual screening algorithm had a sensitivity of 57.1% (95% confidence interval, 54.5-59.8%) and a specificity of 99.7% (95% confidence interval, 99.4-100%). Sensitivity analysis demonstrated a range for sensitivity of 75.0-97.6% of the automated system under varying assumptions. Under all assumptions, the automated system demonstrated higher sensitivity than and comparable specificity to the manual screening method. An automated electronic system identified patients with acute lung injury with high sensitivity and specificity in diverse intensive care units of a large academic medical center. Further studies are needed to evaluate the effect of automated prompts that such a system can initiate on the use of lung protective ventilation in patients with acute lung injury.

  7. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers.

    PubMed

    Avonto, Cristina; Chittiboyina, Amar G; Rua, Diego; Khan, Ikhlas A

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles after incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, 'HTS-DCYA assay', is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Using the emergency department as a screening site for high blood pressure. A method for improving hypertension detection and appropriate referral.

    PubMed

    Mamon, J; Green, L; Levine, D M; Gibson, G; Gurley, H T

    1987-08-01

    This study describes the development and testing of a high blood pressure protocol for use in emergency departments (ED) to enhance detection of those patients appropriate for subsequent referral. The protocol involves two serial blood pressure measurements and a patient interview to determine: 1) previous history of high blood pressure (HBP), 2) treatment in past year for HBP, and 3) usual source of medical care. The accuracy of patient reporting was validated by comparison with the patients' hospital record (reflecting outpatient and inpatient visits). Results indicate that these self-reports have high levels of sensitivity (range 90-100%) and specificity (range 79-96%). Use of the additional patient information increased the sensitivity of the screening protocol in identifying when and where a patient should be referred. Use of this methodology indicates that the protocol is a simple and effective method for HBP screening. The findings also suggest that the ED is an ideal site for screening the "hard-to-reach" hypertensive population.

  9. Performance of prenatal screening using maternal serum and ultrasound markers for Down syndrome in Chinese women: a systematic review and meta-analysis.

    PubMed

    Tu, S; Rosenthal, M; Wang, D; Huang, J; Chen, Y

    2016-09-01

    Controversies about the performance of conventional prenatal screening using maternal serum and ultrasound markers (PSMSUM) in detecting Down syndrome (DS) have been raised as a result of a recently available noninvasive prenatal test based on cell-free fetal DNA sequencing. To evaluate the screening performance of PSMSUM in detecting DS in Chinese women. An exhaustive literature search of MEDLINE, Embase, the Cochrane Library, ISI Web of Science and China BioMedical Disc. Primary studies, published from January 2004 to November 2014, which examined the screening accuracy of PSMSUM in pregnant Chinese women, compared with a reference standard, either chromosomal verification or inspection of the newborn. Data were extracted as screening positive/negative results for Down and non-Down syndrome pregnancies, allowing estimation of sensitivities and specificities. Risks of bias within and across studies were assessed. Screening accuracy measures were pooled using a bivariate random effects regression model. Seventy-eight studies, involving six categories of PSMSUM, were included. Second-trimester double serum [pooled sensitivity (SEN) = 0.80, pooled specificity (SPE) = 0.95] and triple-serum (pooled SEN = 0.79, pooled SPE = 0.96) screening were the predominant PSMSUM methods. The screening performances of these methods achieved the national standard but varied enormously across studies. First-trimester combined screening (pooled SEN = 0.92, pooled SPE = 0.93) and second-trimester quadruple serum screening (median SEN = 0.86, median SPE = 0.96) performed better, but were rarely used. Second-trimester maternal serum screening has the potential to achieve satisfactory screening performance in middle- and low-income countries. The reported enormous range in screening performance of second-trimester PSMSUM calls for urgent implementation of methods for performance optimization. Meta-analysis results show good accuracy of maternal serum and ultrasound screening for trisomy 21 in Chinese women. © 2016 Royal College of Obstetricians and Gynaecologists.

  10. Demand for Colonoscopy in Colorectal Cancer Screening Using a Quantitative Fecal Immunochemical Test and Age/Sex-Specific Thresholds for Test Positivity.

    PubMed

    Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi

    2018-06-01

    Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.

  11. Screening for diabetic retinopathy using digital colour photography and oral fluorescein angiography.

    PubMed

    Newsom, R; Moate, B; Casswell, T

    2000-08-01

    To evaluate digital colour photography and oral fluorescein angiography (OFA) for diabetic retinopathy screening. Thirty-seven patients were selected from either a diabetic retinopathy screening or a medical retina clinic. Three 45 degrees colour digital images and a single macula 45 degrees OFA image were taken from each eye. Standard seven-field stereo photography with ETDRS grading was used as a gold standard for data comparison. The images were assessed by two graders and the results of each method compared using the McNemar test. Five eyes had no diabetic retinopathy, 50 had background diabetic retinopathy, 3 had pre-proliferative diabetic retinopathy, 11 had proliferative disease and 3 had quiescent posttreatment disease. Clinically significant macular oedema was present in 25 eyes and absent in 48. For grading diabetic retinopathy digital colour photography produced a sensitivity of 0.87 (specificity 0.83); OFA produced a sensitivity of 0.87 (specificity 0.80) (p = 0.1). For the detection of diabetic maculopathy, the sensitivity of digital colour photography was 0.48 (specificity of 0.95) and for OFA was 0.87 (specificity 0.87) (p < 0.01). This pilot study has shown that both digital colour photography and OFA compare well with conventional methods for diabetic retinopathy screening. The results encourage the further evaluation of OFA in the screening for diabetic maculopathy.

  12. Phaeochromocytoma: diagnostic challenges for biochemical screening and diagnosis.

    PubMed

    Barron, Jeffrey

    2010-08-01

    The aim of this article is to provide knowledge of the origin of catecholamines and metabolites so that there can be an informed approach to the methods for biochemical screening for a possible phaeochromocytoma; The article includes a review of catecholamine and metadrenaline metabolism, with methods used in biochemical screening. In the adrenal medulla and a phaeochromocytoma, catecholamines continuously leak from chromaffin granules into the cytoplasm and are converted to metadrenalines. For a phaeochromocytoma to become biochemically detectable, metnoradrenaline secretion needs to rise fourfold, whereas noradrenaline secretion needs to rise 15-fold. The prevalence of a sporadic phaeochromocytoma is low; therefore false-positive results exceed true-positive results. Assay sensitivity is high because it is important not to miss a possible phaeochromocytoma. The use of urine or plasma fractionated metadrenalines as the first-line test has been recommended due to improved sensitivity. A negative result excludes a phaeochromocytoma. Only after a sporadic phaeochromocytoma has been diagnosed biochemically is it cost effective to request imaging. Sensitivities and specificities of the assays differ according to pre-test probabilities of the presence of a phaeochromocytoma, with hereditary and incidentalomas having a higher pre-test probability than sporadic phaeochromocytoma. In conclusion, in screening for a possible phaeochromocytoma, biochemical investigations should be completed first to exclude or establish the diagnosis. The preferred biochemical screening test is fractionated metadrenalines, including methoxytyramine so as not to miss dopamine-secreting tumours.

  13. A mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders

    PubMed Central

    Cui, Naiwen; Zhang, Huidan; Schneider, Nils; Tao, Ye; Asahara, Haruichi; Sun, Zhiyi; Cai, Yamei; Koehler, Stephan A.; de Greef, Tom F. A.; Abbaspourrad, Alireza; Weitz, David A.; Chong, Shaorong

    2016-01-01

    Drop-based microfluidics have recently become a novel tool by providing a stable linkage between phenotype and genotype for high throughput screening. However, use of drop-based microfluidics for screening high-affinity peptide binders has not been demonstrated due to the lack of a sensitive functional assay that can detect single DNA molecules in drops. To address this sensitivity issue, we introduced in vitro two-hybrid system (IVT2H) into microfluidic drops and developed a streamlined mix-and-read drop-IVT2H method to screen a random DNA library. Drop-IVT2H was based on the correlation between the binding affinity of two interacting protein domains and transcriptional activation of a fluorescent reporter. A DNA library encoding potential peptide binders was encapsulated with IVT2H such that single DNA molecules were distributed in individual drops. We validated drop-IVT2H by screening a three-random-residue library derived from a high-affinity MDM2 inhibitor PMI. The current drop-IVT2H platform is ideally suited for affinity screening of small-to-medium-sized libraries (103–106). It can obtain hits within a single day while consuming minimal amounts of reagents. Drop-IVT2H simplifies and accelerates the drop-based microfluidics workflow for screening random DNA libraries, and represents a novel alternative method for protein engineering and in vitro directed protein evolution. PMID:26940078

  14. Screening of fluoroquinolone residues in caprine milk using a 5-kg luminescence photometer

    USDA-ARS?s Scientific Manuscript database

    A terbium-sensitized luminescence (TSL) method was developed to screen presence of residues of four fluoroquinolones (FQ) registered in caprine milk in the European Union: enrofloxacin, ciprofloxacin, flumequine, and danofloxacin. After extraction in McIlvaine buffer and SPE cleanup, TSL was measure...

  15. Validation of the Arab Youth Mental Health scale as a screening tool for depression/anxiety in Lebanese children

    PubMed Central

    2011-01-01

    Background Early detection of common mental disorders, such as depression and anxiety, among children and adolescents requires the use of validated, culturally sensitive, and developmentally appropriate screening instruments. The Arab region has a high proportion of youth, yet Arabic-language screening instruments for mental disorders among this age group are virtually absent. Methods We carried out construct and clinical validation on the recently-developed Arab Youth Mental Health (AYMH) scale as a screening tool for depression/anxiety. The scale was administered with 10-14 year old children attending a social service center in Beirut, Lebanon (N = 153). The clinical assessment was conducted by a child and adolescent clinical psychiatrist employing the DSM IV criteria. We tested the scale's sensitivity, specificity, and internal consistency. Results Scale scores were generally significantly associated with how participants responded to standard questions on health, mental health, and happiness, indicating good construct validity. The results revealed that the scale exhibited good internal consistency (Cronbach's alpha = 0.86) and specificity (79%). However, it exhibited moderate sensitivity for girls (71%) and poor sensitivity for boys (50%). Conclusions The AYMH scale is useful as a screening tool for general mental health states and a valid screening instrument for common mental disorders among girls. It is not a valid instrument for detecting depression and anxiety among boys in an Arab culture. PMID:21435213

  16. Comparison of Alcohol Use Disorder Screens During College Athlete Pre-Participation Evaluations.

    PubMed

    Majka, Erek; Graves, Travis; Diaz, Vanessa A; Player, Marty S; Dickerson, Lori M; Gavin, Jennifer K; Wessell, Andrea

    2016-05-01

    The US Preventive Services Task Force (USPSTF) recommends screening adults for alcohol misuse, a challenge among young adults who may not have regular primary care. The pre-participation evaluation (PPE) provides an opportunity for screening, but traditional screening tools require extra time in an already busy visit. The objective of this study was to compare the 10-item Alcohol Use Disorders Identification Test (AUDIT) with a single-question alcohol misuse screen in a population of college-aged athletes. This cross-sectional study was performed during an athletic PPE clinic at a college in the Southeastern United States among athletes ages 18 years and older. Written AUDIT and single-question screen "How many times in the past year have you had X or more drinks in a day?" (five for men, four for women) asked orally were administered to each participant. Sensitivity, specificity, and positive and negative predictive values for the single-question screen were compared to AUDIT. A total of 225 athletes were screened; 60% were female; 29% screened positive by AUDIT; 59% positive by single-question instrument. Males were more likely to screen positive by both methods. Compared to the AUDIT, the brief single-question screen had 92% sensitivity for alcohol misuse and 55% specificity. The negative predictive value of the single-question screen was 95% compared to AUDIT. A single-question screen for alcohol misuse in college-aged athletes had a high sensitivity and negative predictive value compared to the more extensive AUDIT screen. Ease of administration of this screening tool is ideal for use within the pre-participation physical among college-aged athletes who may not seek regular medical care.

  17. [Interval cancers and episode sensitivity in population-based screening programmes for colorectal cancer: a systematic review].

    PubMed

    Domènech, Xènia; Garcia, Montse; Benito, Llúcia; Binefa, Gemma; Vidal, Carmen; Milà, Núria; Moreno, Víctor

    2015-01-01

    To describe interval cancers (IC) and the sensitivity of colorectal cancer (CRC) screening programmes. A systematic review of the literature was conducted through a MEDLINE (PubMed) search. The search strategy combined the terms 'interval cancer', 'false negative', 'mass screening', 'screening' 'early detection of cancer', 'colorectal cancer' and 'bowel cancer'. Inclusion criteria consisted of population-based screening programmes, original articles written in English or Spanish and publication dates between 1999/01/01 and 2015/02/28. A narrative synthesis of the included articles was performed detailing the characteristics of the screening programmes, the IC rate, and the information sources used in each study. Thirteen articles were included. The episode sensitivity of CRC screening programmes ranged from 42.2% to 65.3% in programmes using the guaiac test and between 59.1% and 87.0% with the immunochemical test. We found a higher proportion of women who were diagnosed with IC and these lesions were mainly located in the proximal colon. There is wide variability in the IC rate in CRC programmes. To ensure comparability between programmes, there is a need for consensus on the working definition of IC and the methods used for their identification and quantification. Copyright © 2014 SESPAS. Published by Elsevier Espana. All rights reserved.

  18. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  19. Diagnostic Validity of High-Density Barium Sulfate in Gastric Cancer Screening: Follow-up of Screenees by Record Linkage with the Osaka Cancer Registry

    PubMed Central

    Yamamoto, Kenyu; Yamazaki, Hideo; Kuroda, Chikazumi; Kubo, Tsugio; Oshima, Akira; Katsuda, Toshizo; Kuwano, Tadao; Takeda, Yoshihiro

    2010-01-01

    Background The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate. Methods The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated. Results The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests. Conclusions Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis. PMID:20551581

  20. Sensitivity of neuroprogenitor cells to chemical-induced apoptosis using a multiplexed assay suitable for high-throughput screening*

    EPA Science Inventory

    AbstractHigh-throughput methods are useful for rapidly screening large numbers of chemicals for biological activity, including the perturbation of pathways that may lead to adverse cellular effects. In vitro assays for the key events of neurodevelopment, including apoptosis, may ...

  1. [Screening for risk of child abuse and neglect. A practicable method?].

    PubMed

    Kindler, H

    2010-10-01

    Selective primary prevention programs for child abuse and neglect depend on risk screening instruments that have the goal of systematically identifying families who can profit most from early help. Based on a systematic review of longitudinal studies, a set of established risk factors for early child abuse and neglect is presented. Nearly half of the items included in screening instruments can be seen as validated. Available studies indicate a high sensitivity of risk screening instruments. Positive predictive values, however, are low. Overall, the use of risk screening instruments in the area of primary prevention for families at risk represents a feasible method, as long as stigmatizing effects can be avoided and participating families also benefit beyond preventing endangerment.

  2. Automated cloud screening of AVHRR imagery using split-and-merge clustering

    NASA Technical Reports Server (NTRS)

    Gallaudet, Timothy C.; Simpson, James J.

    1991-01-01

    Previous methods to segment clouds from ocean in AVHRR imagery have shown varying degrees of success, with nighttime approaches being the most limited. An improved method of automatic image segmentation, the principal component transformation split-and-merge clustering (PCTSMC) algorithm, is presented and applied to cloud screening of both nighttime and daytime AVHRR data. The method combines spectral differencing, the principal component transformation, and split-and-merge clustering to sample objectively the natural classes in the data. This segmentation method is then augmented by supervised classification techniques to screen clouds from the imagery. Comparisons with other nighttime methods demonstrate its improved capability in this application. The sensitivity of the method to clustering parameters is presented; the results show that the method is insensitive to the split-and-merge thresholds.

  3. A high-sensitivity ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method for screening synthetic cannabinoids and other drugs of abuse in urine.

    PubMed

    Sundström, Mira; Pelander, Anna; Angerer, Verena; Hutter, Melanie; Kneisel, Stefan; Ojanperä, Ilkka

    2013-10-01

    The continuing emergence of designer drugs imposes high demands on the scope and sensitivity of toxicological drug screening procedures. An ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method was developed for screening and simultaneous confirmation of both designer drugs and other drugs of abuse in urine samples in a single run. The method covered selected synthetic cannabinoids and cathinones, amphetamines, natural cannabinoids, opioids, cocaine and other important drugs of abuse, together with their main urinary metabolites. The database consisted of 277 compounds with molecular formula and exact monoisotopic mass; retention time was included for 192 compounds, and primary and secondary qualifier ion exact mass for 191 and 95 compounds, respectively. Following a solid-phase extraction, separation was performed by UHPLC and mass analysis by HR-TOFMS. MS, and broad-band collision-induced dissociation data were acquired at m/z range 50-700. Compound identification was based on a reverse database search with acceptance criteria for retention time, precursor ion mass accuracy, isotopic pattern and abundance of qualifier ions. Mass resolving power in spiked urine samples was on average FWHM 23,500 and mass accuracy 0.3 mDa. The mean and median cut-off concentrations determined for 75 compounds were 4.2 and 1 ng/mL, respectively. The range of cut-off concentrations for synthetic cannabinoids was 0.2-60 ng/mL and for cathinones 0.7-15 ng/mL. The method proved to combine high sensitivity and a wide scope in a manner not previously reported in drugs of abuse screening. The method's feasibility was demonstrated with 50 authentic urine samples.

  4. Evaluation of 3D-CPA, HR-HPV, and TCT joint detection on cervical disease screening.

    PubMed

    Liang, Hui; Fu, Min; Zhou, Jian; Song, Lei

    2016-08-01

    The application value of three-dimensional color power angiography (3D-CPA), high-risk human papillomavirus (HR-HPV), ThinPrep cytology test (TCT) joint detection on cervical disease screening was investigated. In total, 1,900 patients that were examined in Gynecological and Cervix Clinic of Maternal and Child Care Service Center of Xuzhou from June 2012 to March 2015 were enrolled in the present study. After admission, the patients underwent TCT, HR-HPV and 3D-CPA examinations, and vascular morphology and typing, vascularization index (VI) were recorded. Colposcopic biopsy was performed in patients with a positive outcome of any of the three indices. Pathological diagnosis was taken as the golden standard to assess the sensitivity, specificity, diagnostic rate, and Youden index of the three methods being used independently or jointly. Of the 1,900 patients, 276 cases (14.53%) were HR-HPV-positive, 214 cases (11.26%) were VI-positive and 164 cases (8.63%) were TCT-positive. A total of 418 cases were confirmed with a positive outcome of any of the three indices and a cervical biopsy was obtained. Of the 418 cases, 162 cases (38.75%) were diagnosed with chronic cervicitis, 146 cases with low-level cervical intraepithelial neoplasia (CIN) (34.93%), 104 cases (24.88%) with high level CIN, 6 cases (1.44%) with cervical cancer. Histology more than low level CIN was defined as positive: i) screening results when the three methods were used independently: HPV was confirmed with the highest sensitivity (90.63%), VI with the highest specificity (83.95%), and HPV with the highest diagnostic accuracy (83.73%); ii) screening results under HPV+TCT and HPV+TCT+VI: HPV+TCT+VI was confirmed with the highest sensitivity and specificity: sensitivity (94.53%), specificity (81.48%), diagnosis coincidence rate (89.47%) and the highest Youden index of 0.760; and iii) vascular morphology and grading were significantly different in the early stage cervical carcinoma, high level CIM, and cervicitis groups. In conclusion, the joint detection of 3D-CPA, HR-HPV, and TCT improved the sensitivity and accuracy of cervical disease screening. 3D-CPA technology may therefore be used as an auxiliary screening method for cervical cancer.

  5. Validation of a Nutrition Screening Tool for Pediatric Patients with Cystic Fibrosis.

    PubMed

    Souza Dos Santos Simon, Miriam Isabel; Forte, Gabriele Carra; da Silva Pereira, Juliane; da Fonseca Andrade Procianoy, Elenara; Drehmer, Michele

    2016-05-01

    In cystic fibrosis (CF), nutrition diagnosis is of critical relevance because the early identification of nutrition-related compromise enables early, adequate intervention and, consequently, influences patient prognosis. Up to now, there has not been a validated nutrition screening tool that takes into consideration clinical variables. To validate a specific nutritional risk screening tool for patients with CF based on clinical variables, anthropometric parameters, and dietary intake. Cross-sectional study. The nutrition screening tool was compared with a risk screening tool proposed by McDonald and the Cystic Fibrosis Foundation criteria. Patients aged 6 to 18 years, with a diagnosis of CF confirmed by two determinations of elevated chloride level in sweat (sweat test) and/or by identification of two CF-associated genetic mutations who were receiving follow-up care through the outpatient clinic of a Cystic Fibrosis Treatment Center. Earlier identification of nutritional risk in CF patients aged 6 to 18 years when a new screening tool was applied. Agreement among the tested methods was assessed by means of the kappa coefficient for categorical variables. Sensitivity, specificity, and accuracy values were calculated. The significance level was set at 5% (P<0.05). Statistical analyses were carried out in PASW Statistics for Windows version 18.0 (2009, SPSS Inc). Eighty-two patients (49% men, aged 6 to 18 years) were enrolled in the study. The agreement between the proposed screening tool and the tool for screening nutritional risk for CF by the McDonald method was good (κ=0.804; P<0.001) and the sensitivity and specificity was 85% and 95%, respectively. Agreement with the Cystic Fibrosis Foundation criteria was lower (κ=0.418; P<0.001), and the sensitivity and specificity were both 72%. The proposed screening tool with defined clinical variables promotes earlier identification of nutritional risk in pediatric patients with CF. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  6. Combined zebrafish-yeast chemical-genetic screens reveal gene-copper-nutrition interactions that modulate melanocyte pigmentation.

    PubMed

    Ishizaki, Hironori; Spitzer, Michaela; Wildenhain, Jan; Anastasaki, Corina; Zeng, Zhiqiang; Dolma, Sonam; Shaw, Michael; Madsen, Erik; Gitlin, Jonathan; Marais, Richard; Tyers, Mike; Patton, E Elizabeth

    2010-01-01

    Hypopigmentation is a feature of copper deficiency in humans, as caused by mutation of the copper (Cu(2+)) transporter ATP7A in Menkes disease, or an inability to absorb copper after gastric surgery. However, many causes of copper deficiency are unknown, and genetic polymorphisms might underlie sensitivity to suboptimal environmental copper conditions. Here, we combined phenotypic screens in zebrafish for compounds that affect copper metabolism with yeast chemical-genetic profiles to identify pathways that are sensitive to copper depletion. Yeast chemical-genetic interactions revealed that defects in intracellular trafficking pathways cause sensitivity to low-copper conditions; partial knockdown of the analogous Ap3s1 and Ap1s1 trafficking components in zebrafish sensitized developing melanocytes to hypopigmentation in low-copper environmental conditions. Because trafficking pathways are essential for copper loading into cuproproteins, our results suggest that hypomorphic alleles of trafficking components might underlie sensitivity to reduced-copper nutrient conditions. In addition, we used zebrafish-yeast screening to identify a novel target pathway in copper metabolism for the small-molecule MEK kinase inhibitor U0126. The zebrafish-yeast screening method combines the power of zebrafish as a disease model with facile genome-scale identification of chemical-genetic interactions in yeast to enable the discovery and dissection of complex multigenic interactions in disease-gene networks.

  7. Screening for Chlamydia trachomatis in asymptomatic women in Hungary. An epidemiological and cost-effectiveness analysis.

    PubMed

    Nyári, T; Nyári, C; Woodward, M; Mészáros, G; Deák, J; Nagy, E; Kovács, L

    2001-04-01

    A multicenter survey was carried out in order to determine the prevalence and risk factors for Chlamydia trachomatis infection in the population of asymptomatic women in Hungary. Results were used to carry out a cost-effectiveness analysis of screening for chlamydial infection in women with asymptomatic genital infections. The non-amplified nucleic acid hybridization method (PACE 2 Gen-Probe) was used to diagnose C. trachomatis and Bayes' theorem was applied to assess the prevalence of the infection. Multiple logistic regression analysis was performed to differentiate the risk factors for chlamydial infections. According to the test, the prevalence of Chlamydia trachomatis among 1300 pregnant women was 4.5%. The sensitivity and specificity of the test are estimated to be 70% and 99%, respectively. After Bayes' correction, the overall estimated prevalence of chlamydial infection was 5.1%. There were significant differences in proportions of chlamydial infection in different regions, and also in different age groups and different family status groups. The highest rate was for women aged below 20 years: 16.9%. Cost-effectiveness analysis, with associated sensitivity analysis was carried out for women aged below 20 years. Three screening strategies were compared: using the ELISA method, using amplified Gen-Probe method and no screening. The amplified Gen-Probe method was best provided, the infection prevalence exceeded 16.7%, the PID rate exceeded 24% and the probability of tubal infertility in untreated women exceeded 25%. We conclude that screening with amplified Gen-Probe assays (followed by treatment of positive patients) is the preferred screening strategy for young women in Hungary.

  8. Screening for Pancreatic Cancer

    PubMed Central

    Brand, Randall E.

    2007-01-01

    Despite improvements in the clinical and surgical management of pancreatic cancer, limited strides have been made in the early detection of this highly lethal malignancy. The majority of localized pancreatic tumors are asymptomatic, and the recognized presenting symptoms of pancreatic adenocarcinoma are often vague and heterogeneous in nature. These factors, coupled with the lack of a sensitive and noninvasive screening method, have made population-based screening for pancreatic cancer impossible. Nevertheless, at least two large institutions have performed multimodality-screening protocols for individuals with high risk of pancreatic cancer based on genetic predisposition and strong family history. Abnormalities noted during these screening protocols prompted further investigation or surgery that resulted in the discovery of benign, potentially malignant, and malignant pancreatic lesions. In addition to ductal epithelial pancreatic intraepithelial neoplasia, greater sensitivity has recently been achieved in the identification and characterization of precancerous mucinous pancreatic tumors. Advancements in proteomics and DNA microarray technology may confirm serum-based biomarkers that could be incorporated into future screening algorithms for pancreatic cancer. PMID:21960811

  9. Photovoltaic and Impedance Spectroscopy Study of Screen-Printed TiO₂ Based CdS Quantum Dot Sensitized Solar Cells.

    PubMed

    Atif, M; Farooq, W A; Fatehmulla, Amanullah; Aslam, M; Ali, Syed Mansoor

    2015-01-19

    Cadmium sulphide (CdS) quantum dot sensitized solar cells (QDSSCs) based on screen-printed TiO₂ were assembled using a screen-printing technique. The CdS quantum dots (QDs) were grown by using the Successive Ionic Layer Adsorption and Reaction (SILAR) method. The optical properties were studied by UV-Vis absorbance spectroscopy. Photovoltaic characteristics and impedance spectroscopic measurements of CdS QDSSCs were carried out under air mass 1.5 illuminations. The experimental results of capacitance against voltage indicate a trend from positive to negative capacitance because of the injection of electrons from the Fluorine doped tin oxide (FTO) electrode into TiO₂.

  10. Automatic classification of transiently evoked otoacoustic emissions using an artificial neural network.

    PubMed

    Buller, G; Lutman, M E

    1998-08-01

    The increasing use of transiently evoked otoacoustic emissions (TEOAE) in large neonatal hearing screening programmes makes a standardized method of response classification desirable. Until now methods have been either subjective or based on arbitrary response characteristics. This study takes an expert system approach to standardize the subjective judgements of an experienced scorer. The method that is developed comprises three stages. First, it transforms TEOAEs from waveforms in the time domain into a simplified parameter set. Second, the parameter set is classified by an artificial neural network that has been taught on a large database TEOAE waveforms and corresponding expert scores. Third, additional fuzzy logic rules automatically detect probable artefacts in the waveforms and synchronized spontaneous emission components. In this way, the knowledge of the experienced scorer is encapsulated in the expert system software and thereafter can be accessed by non-experts. Teaching and evaluation of the neural network was based on TEOAEs from a database totalling 2190 neonatal hearing screening tests. The database was divided into learning and test groups with 820 and 1370 waveforms respectively. From each recorded waveform a set of 12 parameters was calculated, representing signal static and dynamic properties. The artifical network was taught with parameter sets of only the learning groups. Reproduction of the human scorer classification by the neural net in the learning group showed a sensitivity for detecting screen fails of 99.3% (299 from 301 failed results on subjective scoring) and a specificity for detecting screen passes of 81.1% (421 of 519 pass results). To quantify the post hoc performance of the net (generalization), the test group was then presented to the network input. Sensitivity was 99.4% (474 from 477) and specificity was 87.3% (780 from 893). To check the efficiency of the classification method, a second learning group was selected out of the previous test group, and the previous learning group was used as the test group. Repeating learning and test procedures yielded 99.3% sensitivity and 80.7% specificity for reproduction, and 99.4% sensitivity and 86.7% specificity for generalization. In all respects, performance was better than for a previously optimized method based simply on cross-correlation between replicate non-linear waveforms. It is concluded that classification methods based on neural networks show promise for application to large neonatal screening programmes utilizing TEOAEs.

  11. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    PubMed Central

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  12. A reporter system for replication-competent gammaretroviruses: the inGluc-MLV-DERSE assay

    PubMed Central

    Aloia, Amanda L.; Duffy, Lisa; Pak, Vladimir; Lee, KyeongEun; Sanchez-Martinez, Silvia; Derse, David; Heidecker, Gisela; Cornetta, Kenneth; Rein, Alan

    2012-01-01

    While novel retroviral vectors for use in gene-therapy products are reducing the potential for formation of replication-competent retrovirus (RCR), it remains crucial to screen products for RCR for both research and clinical purposes. For clinical grade gammaretrovirus-based vectors, RCR screening is achieved by an extended S+L− or marker rescue assay, while standard methods for replication-competent lentivirus detection are still in development. In this report, we describe a rapid and sensitive method for replication-competent gammaretrovirus detection. We used this assay to detect three members of the gammaretrovirus family and compared the sensitivity of our assay with well-established methods for retrovirus detection, including the extended S+L− assay. Results presented here demonstrate that this assay should be useful for gene-therapy product testing. PMID:22402321

  13. Developing a Screening Algorithm for Type II Diabetes Mellitus in the Resource-Limited Setting of Rural Tanzania.

    PubMed

    West, Caroline; Ploth, David; Fonner, Virginia; Mbwambo, Jessie; Fredrick, Francis; Sweat, Michael

    2016-04-01

    Noncommunicable diseases are on pace to outnumber infectious disease as the leading cause of death in sub-Saharan Africa, yet many questions remain unanswered with concern toward effective methods of screening for type II diabetes mellitus (DM) in this resource-limited setting. We aim to design a screening algorithm for type II DM that optimizes sensitivity and specificity of identifying individuals with undiagnosed DM, as well as affordability to health systems and individuals. Baseline demographic and clinical data, including hemoglobin A1c (HbA1c), were collected from 713 participants using probability sampling of the general population. We used these data, along with model parameters obtained from the literature, to mathematically model 8 purposed DM screening algorithms, while optimizing the sensitivity and specificity using Monte Carlo and Latin Hypercube simulation. An algorithm that combines risk assessment and measurement of fasting blood glucose was found to be superior for the most resource-limited settings (sensitivity 68%, sensitivity 99% and cost per patient having DM identified as $2.94). Incorporating HbA1c testing improves the sensitivity to 75.62%, but raises the cost per DM case identified to $6.04. The preferred algorithms are heavily biased to diagnose those with more severe cases of DM. Using basic risk assessment tools and fasting blood sugar testing in lieu of HbA1c testing in resource-limited settings could allow for significantly more feasible DM screening programs with reasonable sensitivity and specificity. Copyright © 2016 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  14. The inclusion of N-terminal pro-brain natriuretic peptide in a sensitive screening strategy for systemic sclerosis-related pulmonary arterial hypertension: a cohort study

    PubMed Central

    2013-01-01

    Introduction Pulmonary arterial hypertension (PAH) is a major cause of mortality in systemic sclerosis (SSc). Screening guidelines for PAH recommend multiple investigations, including annual echocardiography, which together have low specificity and may not be cost-effective. We sought to evaluate the predictive accuracy of serum N-terminal pro-brain natriuretic peptide (NT-proBNP) in combination with pulmonary function tests (PFT) (‘proposed’ algorithm) in a screening algorithm for SSc-PAH. Methods We evaluated our proposed algorithm (PFT with NT-proBNP) on 49 consecutive SSc patients with suspected pulmonary hypertension undergoing right heart catherisation (RHC). The predictive accuracy of the proposed algorithm was compared with existing screening recommendations, and is presented as sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Overall, 27 patients were found to have pulmonary hypertension (PH) at RHC, while 22 had no PH. The sensitivity, specificity, PPV and NPV of the proposed algorithm for PAH was 94.1%, 54.5%, 61.5% and 92.3%, respectively; current European Society of Cardiology (ESC)/European Respiratory Society (ERS) guidelines achieved a sensitivity, specificity, PPV and NPV of 94.1%, 31.8%, 51.6% and 87.5%, respectively. In an alternate case scenario analysis, estimating a PAH prevalence of 10%, the proposed algorithm achieved a sensitivity, specificity, PPV and NPV for PAH of 94.1%, 54.5%, 18.7% and 98.8%, respectively. Conclusions The combination of NT-proBNP with PFT is a sensitive, yet simple and non-invasive, screening strategy for SSc-PAH. Patients with a positive screening result can be referred for echocardiography, and further confirmatory testing for PAH. In this way, it may be possible to shift the burden of routine screening away from echocardiography. The findings of this study should be confirmed in larger studies. PMID:24246100

  15. Fever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan

    PubMed Central

    2011-01-01

    Background Entry screening tends to start with a search for febrile international passengers, and infrared thermoscanners have been employed for fever screening in Japan. We aimed to retrospectively assess the feasibility of detecting influenza cases based on fever screening as a sole measure. Methods Two datasets were collected at Narita International Airport during the 2009 pandemic. The first contained confirmed influenza cases (n = 16) whose diagnosis took place at the airport during the early stages of the pandemic, and the second contained a selected and suspected fraction of passengers (self-reported or detected by an infrared thermoscanner; n = 1,049) screened from September 2009 to January 2010. The sensitivity of fever (38.0°C) for detecting H1N1-2009 was estimated, and the diagnostic performances of the infrared thermoscanners in detecting hyperthermia at cut-off levels of 37.5°C, 38.0°C and 38.5°C were also estimated. Results The sensitivity of fever for detecting H1N1-2009 cases upon arrival was estimated to be 22.2% (95% confidence interval: 0, 55.6) among nine confirmed H1N1-2009 cases, and 55.6% of the H1N1-2009 cases were under antipyretic medications upon arrival. The sensitivity and specificity of the infrared thermoscanners in detecting hyperthermia ranged from 50.8-70.4% and 63.6-81.7%, respectively. The positive predictive value appeared to be as low as 37.3-68.0%. Conclusions The sensitivity of entry screening is a product of the sensitivity of fever for detecting influenza cases and the sensitivity of the infrared thermoscanners in detecting fever. Given the additional presence of confounding factors and unrestricted medications among passengers, reliance on fever alone is unlikely to be feasible as an entry screening measure. PMID:21539735

  16. A fluorescence high throughput screening method for the detection of reactive electrophiles as potential skin sensitizers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avonto, Cristina; Chittiboyina, Amar G.; Rua, Diego

    2015-12-01

    Skin sensitization is an important toxicological end-point in the risk assessment of chemical allergens. Because of the complexity of the biological mechanisms associated with skin sensitization, integrated approaches combining different chemical, biological and in silico methods are recommended to replace conventional animal tests. Chemical methods are intended to characterize the potential of a sensitizer to induce earlier molecular initiating events. The presence of an electrophilic mechanistic domain is considered one of the essential chemical features to covalently bind to the biological target and induce further haptenation processes. Current in chemico assays rely on the quantification of unreacted model nucleophiles aftermore » incubation with the candidate sensitizer. In the current study, a new fluorescence-based method, ‘HTS-DCYA assay’, is proposed. The assay aims at the identification of reactive electrophiles based on their chemical reactivity toward a model fluorescent thiol. The reaction workflow enabled the development of a High Throughput Screening (HTS) method to directly quantify the reaction adducts. The reaction conditions have been optimized to minimize solubility issues, oxidative side reactions and increase the throughput of the assay while minimizing the reaction time, which are common issues with existing methods. Thirty-six chemicals previously classified with LLNA, DPRA or KeratinoSens™ were tested as a proof of concept. Preliminary results gave an estimated 82% accuracy, 78% sensitivity, 90% specificity, comparable to other in chemico methods such as Cys-DPRA. In addition to validated chemicals, six natural products were analyzed and a prediction of their sensitization potential is presented for the first time. - Highlights: • A novel fluorescence-based method to detect electrophilic sensitizers is proposed. • A model fluorescent thiol was used to directly quantify the reaction products. • A discussion of the reaction workflow and critical parameters is presented. • The method could provide a useful tool to complement existing chemical assays.« less

  17. AN APPROACH FOR SCREENING CHOLINESTERASE INHIBITORS IN DRINKING WATER USING AN IMMOBILIZED ENZYME ASSAY

    EPA Science Inventory

    A simple, inexpensive and sensitive method for detecting organophosphate and carbamate insecticides is reported. Acetylcholinesterase was immobilized to PorexR Lateral-FloTM membrane material and remained active for several months at room temperature. The assay was sensitive ...

  18. Development of a novel single tube nested PCR for enhanced detection of cytomegalovirus DNA from dried blood spots.

    PubMed

    Atkinson, C; Emery, V C; Griffiths, P D

    2014-02-01

    Newborn screening for congenital cytomegalovirus (CCMV) using dried blood spots (DBS) has been proposed because many developed countries have DBS screening programmes in place for other diseases. The aim of this study was to develop a rapid, single tube nested polymerase chain reaction (PCR) method for enhanced detection of CMV from DBS compared to existing (single target) real time PCRs. The new method was compared with existing real time PCRs for sensitivity and specificity. Overall sensitivity of the single target PCR assays in both asymptomatic and symptomatic infants with laboratory confirmed congenital CMV was 69% (CMV PCR or culture positive before day 21 of life). In contrast, the single tube nested assay had an increased sensitivity of 81% with100% specificity. Overall the assay detected CMV from a DBS equivalent to an original blood sample which contained 500IU/ml. In conclusion this single tube nested methodology allows simultaneous amplification and detection of CMV DNA in 1.5h removing the associated contamination risk of a two step nested PCR. Owing to its increased sensitivity, it has the potential to be used as a screening assay and ultimately allow early identification and intervention for children with congenital CMV. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. A comparative rapid and sensitive method to screen l-asparaginase producing fungi.

    PubMed

    Dhale, Mohan A; Mohan-Kumari, H Puttananjaiah

    2014-07-01

    Fungi are well known to produce various industrial enzymes and secondary metabolites with different colours. Fungi producing l-asparaginase enzyme are conventionally screened on medium containing phenol red (PR). The contrast between enzyme-hydrolysed zone and unhydrolysed l-asparagine is not very evident and distinct in medium containing PR and bromothymol blue (BB) due to coloured secondary metabolite production. Thus, PR and BB limit and affect the detection and screening method. In the present investigation, an improved method for screening is reported by comparing with PR and BB, wherein methyl red (MR) is incorporated as pH indicator. The enzyme activity was distinctly observed (red and light-yellow) in MR incorporated medium compared to PR and BB. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Evaluation of RealStar Reverse Transcription–Polymerase Chain Reaction Kits for Filovirus Detection in the Laboratory and Field

    PubMed Central

    Rieger, Toni; Kerber, Romy; El Halas, Hussein; Pallasch, Elisa; Duraffour, Sophie; Günther, Stephan; Ölschläger, Stephan

    2016-01-01

    Background. Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing. Methods. The RealStar Filovirus Screen reverse transcription–polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD. Results. The Filovirus Screen kit detected EBOV, Sudan virus, Taï Forest virus, Bundibugyo virus, Reston virus, and Marburg virus and differentiated between the genera Ebolavirus and Marburgvirus. The amount of filovirus RNA that could be detected with a probability of 95% ranged from 11 to 67 RNA copies/reaction on a LightCycler 480 II. The Zaire Ebolavirus kit is based on the Filovirus Screen kit but was optimized for detection of EBOV. It has an improved signal-to-noise ratio at low EBOV RNA concentrations and is somewhat more sensitive than the Filovirus kit. Both kits show significantly lower analytical sensitivity on a SmartCycler II. Clinical evaluation revealed that the SmartCycler II, compared with other real-time PCR platforms, decreases the clinical sensitivity of the Filovirus Screen kit to diagnose EVD at an early stage. Conclusions. The Filovirus Screen kit detects all human-pathogenic filoviruses with good analytical sensitivity if performed on an appropriate real-time PCR platform. High analytical sensitivity is important for early diagnosis of EVD. PMID:27549586

  1. Fully automated screening of immunocytochemically stained specimens for early cancer detection

    NASA Astrophysics Data System (ADS)

    Bell, André A.; Schneider, Timna E.; Müller-Frank, Dirk A. C.; Meyer-Ebrecht, Dietrich; Böcking, Alfred; Aach, Til

    2007-03-01

    Cytopathological cancer diagnoses can be obtained less invasive than histopathological investigations. Cells containing specimens can be obtained without pain or discomfort, bloody biopsies are avoided, and the diagnosis can, in some cases, even be made earlier. Since no tissue biopsies are necessary these methods can also be used in screening applications, e.g., for cervical cancer. Among the cytopathological methods a diagnosis based on the analysis of the amount of DNA in individual cells achieves high sensitivity and specificity. Yet this analysis is time consuming, which is prohibitive for a screening application. Hence, it will be advantageous to retain, by a preceding selection step, only a subset of suspicious specimens. This can be achieved using highly sensitive immunocytochemical markers like p16 ink4a for preselection of suspicious cells and specimens. We present a method to fully automatically acquire images at distinct positions at cytological specimens using a conventional computer controlled microscope and an autofocus algorithm. Based on the thus obtained images we automatically detect p16 ink4a-positive objects. This detection in turn is based on an analysis of the color distribution of the p16 ink4a marker in the Lab-colorspace. A Gaussian-mixture-model is used to describe this distribution and the method described in this paper so far achieves a sensitivity of up to 90%.

  2. TINS, target immobilized NMR screening: an efficient and sensitive method for ligand discovery.

    PubMed

    Vanwetswinkel, Sophie; Heetebrij, Robert J; van Duynhoven, John; Hollander, Johan G; Filippov, Dmitri V; Hajduk, Philip J; Siegal, Gregg

    2005-02-01

    We propose a ligand screening method, called TINS (target immobilized NMR screening), which reduces the amount of target required for the fragment-based approach to drug discovery. Binding is detected by comparing 1D NMR spectra of compound mixtures in the presence of a target immobilized on a solid support to a control sample. The method has been validated by the detection of a variety of ligands for protein and nucleic acid targets (K(D) from 60 to 5000 muM). The ligand binding capacity of a protein was undiminished after 2000 different compounds had been applied, indicating the potential to apply the assay for screening typical fragment libraries. TINS can be used in competition mode, allowing rapid characterization of the ligand binding site. TINS may allow screening of targets that are difficult to produce or that are insoluble, such as membrane proteins.

  3. Laboratory audit as part of the quality assessment of a primary HPV-screening program.

    PubMed

    Hortlund, Maria; Sundström, Karin; Lamin, Helena; Hjerpe, Anders; Dillner, Joakim

    2016-02-01

    As primary HPV screening programs are rolled out, methods are needed for routine quality assurance of HPV laboratory analyzes. To explore the use of similar design for audit as currently used in cytology-based screening, to estimate the clinical sensitivity to identify women at risk for CIN 3 or worse (CIN3+). Population-based cohort study conducted within the cervical screening program in Stockholm, Sweden, in 2011-2012. All women with histopathologically confirmed CIN3+ in the following two years were identified by registry analysis. Primary HPV and cytology screening results were collected. For women who had not been HPV tested, biobanked cytology samples were HPV-tested. If the original HPV result had been negative, the sample and subsequent biopsies were analyzed with broad HPV typing (general primer PCR and Luminex). 154 women had a biobanked prediagnostic cytology sample taken up to 2 years before a histopathologically confirmed CIN3+. The high-risk HPV-positivity was 97% (148/154 women), whereas 143/154 (94%) women had had a cytological abnormality. Among the six HPV-negative samples, one sample was HPV 33 positive in repeat testing whereas the other five cases were HPV-negative also on repeat testing, but HPV-positive in the subsequent tumor tissue. A sensitivity of the HPV test that is higher than the sensitivity of cytology suggests adequate quality of the testing. Regular audits of clinical sensitivity, similar to those of cytology-based screening, should be used also in HPV-based screening programs, in order to continuously monitor the performance of the analyzes. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Allergic sensitization: screening methods

    PubMed Central

    2014-01-01

    Experimental in silico, in vitro, and rodent models for screening and predicting protein sensitizing potential are discussed, including whether there is evidence of new sensitizations and allergies since the introduction of genetically modified crops in 1996, the importance of linear versus conformational epitopes, and protein families that become allergens. Some common challenges for predicting protein sensitization are addressed: (a) exposure routes; (b) frequency and dose of exposure; (c) dose-response relationships; (d) role of digestion, food processing, and the food matrix; (e) role of infection; (f) role of the gut microbiota; (g) influence of the structure and physicochemical properties of the protein; and (h) the genetic background and physiology of consumers. The consensus view is that sensitization screening models are not yet validated to definitively predict the de novo sensitizing potential of a novel protein. However, they would be extremely useful in the discovery and research phases of understanding the mechanisms of food allergy development, and may prove fruitful to provide information regarding potential allergenicity risk assessment of future products on a case by case basis. These data and findings were presented at a 2012 international symposium in Prague organized by the Protein Allergenicity Technical Committee of the International Life Sciences Institute’s Health and Environmental Sciences Institute. PMID:24739743

  5. [Test and programme sensitivities of screening for colorectal cancer in Reggio Emilia].

    PubMed

    Campari, Cinzia; Sassatelli, Romano; Paterlini, Luisa; Camellini, Lorenzo; Menozzi, Patrizia; Cattani, Antonella

    2011-01-01

    to estimate the sensitivity of the immunochemical test for faecal occult blood (FOBT) and the sensitivity of the colorectal tumour screening programme in the province of Reggio Emilia. retrospective cohort study, including a sample of 80,357 people of both genders, aged 50-69, who underwent FOBT, during the first round of the screening programme in the province of Reggio Emilia, from April 2005 to December 2007. incidence of interval cancer. The proportional incidence method was used to estimate the sensitivity of FOBT and of the screening programme. Data were stratified according to gender, age and year of interval. the overall sensitivity of FOBT was 73.2% (95%IC 63.8-80.7). The sensitivity of FOBT was lower in females (70.5% vs 75.1%), higher in the 50-59 age group (78.6% vs 70.2%) and higher in the colon than rectum (75.1% vs 68.9%). The test had a significantly higher sensitivity in the 1st year of interval than in the 2nd (84.4% vs 60.5%; RR=0.39, 95%IC 0.22-0.70), a difference which was confirmed, also when data were stratified according to gender. The overall sensitivity of the programme is 70.9% (95%IC 61.5-78.5). No statistically significant differences were shown, if data were stratified according to gender, age or site. Again the sensitivity in the 1st year was significantly higher than in the 2nd year of interval (83.2% vs 57.0%; RR=0.41, 95%IC 0.24-0.69). Overall our data confirmed the findings of similar Italian studies, despite subgroup analysis showed some differences in sensitivity in our study.

  6. Plasma Septin9 versus fecal immunochemical testing for colorectal cancer screening: a prospective multicenter study.

    PubMed

    Johnson, David A; Barclay, Robert L; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T

    2014-01-01

    Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9-80.9%) and 68.0% (95% CI 58.2-76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5-86.3%) compared with 97.4% (95% CI 94.1-98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% -95% CI 62.5-80.1%) was shown to be statistically non-inferior to FIT (68.0%-95% CI 58.2-76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. ClinicalTrials.gov NCT01580540.

  7. [Primary care screening of problems in the elderly and a proposal for a screening protocol with a multidimensional approach].

    PubMed

    Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele

    2016-07-21

    The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.

  8. IRAS: High-Throughput Identification of Novel Alternative Splicing Regulators.

    PubMed

    Zheng, S

    2016-01-01

    Alternative splicing is a fundamental regulatory process of gene expression. Defects in alternative splicing can lead to various diseases, and modification of disease-causing splicing events presents great therapeutic promise. Splicing outcome is commonly affected by extracellular stimuli and signaling cascades that converge on RNA-binding splicing regulators. These trans-acting factors recognize cis-elements in pre-mRNA transcripts to affect spliceosome assembly and splice site choices. Identification of these splicing regulators and/or upstream modulators has been difficult and traditionally done by piecemeal. High-throughput screening strategies to find multiple regulators of exon splicing have great potential to accelerate the discovery process, but typically confront low sensitivity and low specificity of screening assays. Here we describe a unique screening strategy, IRAS (identifying regulators of alternative splicing), using a pair of dual-output minigene reporters to allow for sensitive detection of exon splicing changes. Each dual-output reporter produces green fluorescent protein (GFP) and red fluorescent protein (RFP) fluorescent signals to assay the two spliced isoforms exclusively. The two complementary minigene reporters alter GFP/RFP output ratios in the opposite direction in response to splicing change. Applying IRAS in cell-based high-throughput screens allows sensitive and specific identification of splicing regulators and modulators for any alternative exons of interest. In comparison to previous high-throughput screening methods, IRAS substantially enhances the specificity of the screening assay. This strategy significantly eliminates false positives without sacrificing sensitive identification of true regulators of splicing. © 2016 Elsevier Inc. All rights reserved.

  9. Controversies in colorectal cancer screening.

    PubMed

    Pox, Christian P

    2014-01-01

    Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.

  10. Laboratory screening markers in gastroenterology--state of the art.

    PubMed

    Kocna, Petr; Vanickova, Zdislava; Zima, Tomas

    2013-06-01

    Screening tests for gastrointestinal diseases acceptable for population with a high sensitivity and high specificity can now be offered by clinical laboratories. This paper summarizes major recent advances in this area of laboratory medicine. Relevant articles published within the last 5 years in the NLM (National Library of Medicine) PubMed - Medline database covering the three gastrointestinal diseases - colorectal cancer, coeliac disease, and atrophic gastritis were included for this overview. In Europe, colorectal cancer (CRCA) is the second most frequent malignant disease. Quantitative immunochemical analysis of the stool for haemoglobin provides the best screening test to date, with both sensitivity and specificity approaching 95%. Even though coeliac disease (CD) affects approximately 1% of the general population, it remains largely unrecognised. Recommended methods for screening currently involve the detection of IgA and IgG antibodies against tissue transglutaminase and deamidated gliadin peptide. Evaluations of screening are now discussed for other diseases of the gastrointestinal tract - such as chronic atrophic gastritis (CAG), and inflammatory bowel disease (IBD). Detection of infection by Helicobacter pylori and stomach-specific plasmatic biomarkers, especially pepsinogen I/II ratio, could help with the prevention of gastric carcinomas. The use of faecal calprotectin as a screening test could substantially reduce the number of invasive methods necessary for the diagnostic work-up of patients with IBD. Screening tests for CRCA and CD have been used worldwide for many years. Screening strategies for gastrointestinal diseases are suggested in the text, based on recent basic science, clinical papers as well as our own experience.

  11. Use of the Analysis of the Volatile Faecal Metabolome in Screening for Colorectal Cancer

    PubMed Central

    2015-01-01

    Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT. PMID:26086914

  12. Two enzyme immunoassays to screen for 2,4-dichlorophenoxyacetic acid in water.

    PubMed

    Fleeker, J

    1987-01-01

    Two solid-phase enzyme immunoassays were developed to measure 2,4-dichlorophenoxyacetic acid (2,4-D), using 2 sets of structurally distinct immunogens and enzyme ligands. The 2,4-D analog, 2-methyl-4-chlorophenoxyacetic acid (MCPA), gave a similar response with both methods, whereas other phenoxy herbicides cross-reacted differently. In method A, the aromatic moiety of 2,4-D was distal from the carrier protein and labeled enzyme, whereas in method B, the acetic acid portion of the herbicide was distal. The use of both methods to screen for this herbicide in ground water and municipal and river water reduced the number of false-positive responses. Water sources having a low background response could be monitored with either method alone. When a concentration step, with disposable C18 extraction columns, was used, the limit of sensitivity was 5 micrograms/L. Method A was the more sensitive of the 2 methods with a limit of detection of 10 micrograms/L without the concentration step.

  13. Colorimetry and SERS dual-mode detection of telomerase activity: combining rapid screening with high sensitivity.

    PubMed

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping

    2014-01-01

    As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an "elongate and capture" procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.

  14. Performance of alternative strategies for primary cervical cancer screening in sub-Saharan Africa: systematic review and meta-analysis of diagnostic test accuracy studies

    PubMed Central

    Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick

    2015-01-01

    Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020

  15. How to improve colon cancer screening rates

    PubMed Central

    Alberti, Luiz Ronaldo; Garcia, Diego Paim Carvalho; Coelho, Debora Lucciola; De Lima, David Correa Alves; Petroianu, Andy

    2015-01-01

    Colorectal carcinoma is a common cause of death throughout the world and may be prevented by routine control, which can detect precancerous neoplasms and early cancers before they undergo malignant transformation or metastasis. Three strategies may improve colon cancer screening rates: convince the population about the importance of undergoing a screening test; achieve higher efficacy in standard screening tests and make them more available to the community and develop new more sensitive and efficacious screening methods and make them available as routine tests. In this light, the present study seeks to review these three means through which to increase colon cancer screening rates. PMID:26688708

  16. Sensitivity and specificity of Norwegian optometrists' evaluation of diabetic retinopathy in single-field retinal images - a cross-sectional experimental study.

    PubMed

    Sundling, Vibeke; Gulbrandsen, Pål; Straand, Jørund

    2013-01-10

    In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a "gold standard", images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education.

  17. A Novel Extraction Method Combining Plasma with a Whole-Blood Fraction Shows Excellent Sensitivity and Reproducibility for Patients at High Risk for Invasive Aspergillosis

    PubMed Central

    Springer, Jan; Schloßnagel, Hannes; Heinz, Werner; Doedt, Thomas; Soeller, Rainer; Einsele, Hermann

    2012-01-01

    Diagnosis of invasive aspergillosis (IA) is still a major problem in routine clinical practice. Early diagnosis is essential for a good patient prognosis. PCR is a highly sensitive method for the detection of nucleic acids and could play an important role in improving the diagnosis of fungal infections. Therefore, a novel DNA extraction method, ultraclean production (UCP), was developed allowing purification of both cellular and cell-free circulating fungal DNA. In this prospective study we evaluated the commercially available UCP extraction system and compared it to an in-house system. Sixty-three patients at high risk for IA were screened twice weekly, and DNA extracted by both methods was cross-analyzed, in triplicate, by two different real-time PCR assays. The negative predictive values were high for all methods (94.3 to 100%), qualifying them as screening methods, but the sensitivity and diagnostic odds ratios were higher using the UCP extraction method. Sensitivity ranged from 33.3 to 66.7% using the in-house extracts to 100% using the UCP extraction method. Most of the unclassified patients showed no positive PCR results; however, single-positive PCR replicates were observed in some cases. These can bear clinical relevance but should be interpreted with additional clinical and laboratory data. The PCR assays from the UCP extracts showed greater reproducibility than the in-house method for probable IA patients. The standardized UCP extraction method yielded superior results, with regard to sensitivity and reproducibility, than the in-house method. This was independent of the PCR assay used to detect fungal DNA in the sample extracts. PMID:22593600

  18. Determinants of Cervical Cancer Screening Accuracy for Visual Inspection with Acetic Acid (VIA) and Lugol’s Iodine (VILI) Performed by Nurse and Physician

    PubMed Central

    Raifu, Amidu O.; El-Zein, Mariam; Sangwa-Lugoma, Ghislain; Ramanakumar, Agnihotram; Walter, Stephen D.

    2017-01-01

    Background Visual inspection with acetic acid (VIA) and Lugol’s iodine (VILI) are used to screen women for cervical cancer in low-resource settings. Little is known about correlates of their diagnostic accuracy by healthcare provider. We examined determinants of VIA and VILI screening accuracy by examiner in a cross-sectional screening study of 1528 women aged 30 years or older in a suburb of Kinshasa, Democratic Republic of Congo. Methods We used a logistic regression model for sensitivity and specificity to estimate the diagnostic accuracy of VIA and VILI, independently performed by nurse and physician, as a function of sociodemographic and reproductive health characteristics. Results Nurses rated tests as positive more often than physicians (36.3% vs 30.2% for VIA, 26.2% vs 25.2% for VILI). Women’s age was the most important determinant of performance. It was inversely associated with sensitivity (nurse’s VIA: p<0.001, nurse’s VILI: p = 0.018, physician’s VIA: p = 0.005, physician’s VILI: p = 0.006) but positively associated with specificity (all four combinations: p<0.001). Increasing parity adversely affected sensitivity and specificity, but the effects on sensitivity were significant for nurses only. The screening performance of physician’s assessment was significantly better than the nurse’s (difference in sensitivity: VIA = 13%, VILI = 16%; difference in specificity: VIA = 6%, VILI = 1%). Conclusions Age and parity influence the performance of visual tests for cervical cancer screening. Proper training of local healthcare providers in the conduct of these tests should take into account these factors for improved performance of VIA and VILI in detecting cervical precancerous lesions among women in limited-resource settings. PMID:28107486

  19. Fragment screening of cyclin G-associated kinase by weak affinity chromatography.

    PubMed

    Meiby, Elinor; Knapp, Stefan; Elkins, Jonathan M; Ohlson, Sten

    2012-11-01

    Fragment-based drug discovery (FBDD) has become a new strategy for drug discovery where lead compounds are evolved from small molecules. These fragments form low affinity interactions (dissociation constant (K(D)) = mM - μM) with protein targets, which require fragment screening methods of sufficient sensitivity. Weak affinity chromatography (WAC) is a promising new technology for fragment screening based on selective retention of fragments by a drug target. Kinases are a major pharmaceutical target, and FBDD has been successfully applied to several of these targets. In this work, we have demonstrated the potential to use WAC in combination with mass spectrometry (MS) detection for fragment screening of a kinase target-cyclin G-associated kinase (GAK). One hundred seventy fragments were selected for WAC screening by virtual screening of a commercial fragment library against the ATP-binding site of five different proteins. GAK protein was immobilized on a capillary HPLC column, and compound binding was characterized by frontal affinity chromatography. Compounds were screened in sets of 13 or 14, in combination with MS detection for enhanced throughput. Seventy-eight fragments (46 %) with K(D) < 200 μM were detected, including a few highly efficient GAK binders (K(D) of 2 μM; ligand efficiency = 0.51). Of special interest is that chiral screening by WAC may be possible, as two stereoisomeric fragments, which both contained one chiral center, demonstrated twin peaks. This ability, in combination with the robustness, sensitivity, and simplicity of WAC makes it a new method for fragment screening of considerable potential.

  20. A high throughput screen for biomining cellulase activity from metagenomic libraries.

    PubMed

    Mewis, Keith; Taupp, Marcus; Hallam, Steven J

    2011-02-01

    Cellulose, the most abundant source of organic carbon on the planet, has wide-ranging industrial applications with increasing emphasis on biofuel production (1). Chemical methods to modify or degrade cellulose typically require strong acids and high temperatures. As such, enzymatic methods have become prominent in the bioconversion process. While the identification of active cellulases from bacterial and fungal isolates has been somewhat effective, the vast majority of microbes in nature resist laboratory cultivation. Environmental genomic, also known as metagenomic, screening approaches have great promise in bridging the cultivation gap in the search for novel bioconversion enzymes. Metagenomic screening approaches have successfully recovered novel cellulases from environments as varied as soils (2), buffalo rumen (3) and the termite hind-gut (4) using carboxymethylcellulose (CMC) agar plates stained with congo red dye (based on the method of Teather and Wood (5)). However, the CMC method is limited in throughput, is not quantitative and manifests a low signal to noise ratio (6). Other methods have been reported (7,8) but each use an agar plate-based assay, which is undesirable for high-throughput screening of large insert genomic libraries. Here we present a solution-based screen for cellulase activity using a chromogenic dinitrophenol (DNP)-cellobioside substrate (9). Our library was cloned into the pCC1 copy control fosmid to increase assay sensitivity through copy number induction (10). The method uses one-pot chemistry in 384-well microplates with the final readout provided as an absorbance measurement. This readout is quantitative, sensitive and automated with a throughput of up to 100X 384-well plates per day using a liquid handler and plate reader with attached stacking system.

  1. Rapid, sensitive and reproducible method for point-of-collection screening of liquid milk for adulterants using a portable Raman spectrometer with novel optimized sample well

    NASA Astrophysics Data System (ADS)

    Nieuwoudt, Michel K.; Holroyd, Steve E.; McGoverin, Cushla M.; Simpson, M. Cather; Williams, David E.

    2017-02-01

    Point-of-care diagnostics are of interest in the medical, security and food industry, the latter particularly for screening food adulterated for economic gain. Milk adulteration continues to be a major problem worldwide and different methods to detect fraudulent additives have been investigated for over a century. Laboratory based methods are limited in their application to point-of-collection diagnosis and also require expensive instrumentation, chemicals and skilled technicians. This has encouraged exploration of spectroscopic methods as more rapid and inexpensive alternatives. Raman spectroscopy has excellent potential for screening of milk because of the rich complexity inherent in its signals. The rapid advances in photonic technologies and fabrication methods are enabling increasingly sensitive portable mini-Raman systems to be placed on the market that are both affordable and feasible for both point-of-care and point-of-collection applications. We have developed a powerful spectroscopic method for rapidly screening liquid milk for sucrose and four nitrogen-rich adulterants (dicyandiamide (DCD), ammonium sulphate, melamine, urea), using a combined system: a small, portable Raman spectrometer with focusing fibre optic probe and optimized reflective focusing wells, simply fabricated in aluminium. The reliable sample presentation of this system enabled high reproducibility of 8% RSD (residual standard deviation) within four minutes. Limit of detection intervals for PLS calibrations ranged between 140 - 520 ppm for the four N-rich compounds and between 0.7 - 3.6 % for sucrose. The portability of the system and reliability and reproducibility of this technique opens opportunities for general, reagentless adulteration screening of biological fluids as well as milk, at point-of-collection.

  2. A simple and sensitive high-throughput GFP screening in woody and herbaceous plants.

    PubMed

    Hily, Jean-Michel; Liu, Zongrang

    2009-03-01

    Green fluorescent protein (GFP) has been used widely as a powerful bioluminescent reporter, but its visualization by existing methods in tissues or whole plants and its utilization for high-throughput screening remains challenging in many species. Here, we report a fluorescence image analyzer-based method for GFP detection and its utility for high-throughput screening of transformed plants. Of three detection methods tested, the Typhoon fluorescence scanner was able to detect GFP fluorescence in all Arabidopsis thaliana tissues and apple leaves, while regular fluorescence microscopy detected it only in Arabidopsis flowers and siliques but barely in the leaves of either Arabidopsis or apple. The hand-held UV illumination method failed in all tissues of both species. Additionally, the Typhoon imager was able to detect GFP fluorescence in both green and non-green tissues of Arabidopsis seedlings as well as in imbibed seeds, qualifying it as a high-throughput screening tool, which was further demonstrated by screening the seedlings of primary transformed T(0) seeds. Of the 30,000 germinating Arabidopsis seedlings screened, at least 69 GFP-positive lines were identified, accounting for an approximately 0.23% transformation efficiency. About 14,000 seedlings grown in 16 Petri plates could be screened within an hour, making the screening process significantly more efficient and robust than any other existing high-throughput screening method for transgenic plants.

  3. Comparison of Triage Strategies for HPV-Positive Women: Canadian Cervical Cancer Screening Trial Results.

    PubMed

    Isidean, Sandra D; Mayrand, Marie-Hélène; Ramanakumar, Agnihotram V; Rodrigues, Isabel; Ferenczy, Alex; Ratnam, Sam; Coutlée, François; Franco, Eduardo L

    2017-06-01

    Background: High-risk human papillomavirus (HR-HPV) testing has become a preferred cervical cancer screening strategy in some countries due to its superior sensitivity over cytology-based methods for identifying cervical intraepithelial neoplasia of grade 2 or worse (CIN2 + ). Improved sensitivity has been accompanied by reductions in specificity and concerns regarding overscreening and overtreatment of women with transient or nonprogressing HR-HPV infections. Triage of HR-HPV + women to colposcopy is, thus, warranted for appropriate management and treatment. Methods: Using data from the Canadian Cervical Cancer Screening Trial (CCCaST), we compared the performance of cytology and HR-HPV strategies to detect CIN2 + among HR-HPV + women (age, 30-69 years). Colposcopy referral rates and performance gains from adding other HR-HPV genotypes to HPV16/18 + triage were also evaluated. Results: A strategy referring all women HPV16/18 + and HPV16/18 - , but with atypical squamous cells of undetermined significance or worse cytology (ASC-US + ) had the highest sensitivity [82.5%; 95% confidence interval (CI), 70.9%-91.0%] but yielded the highest colposcopy referral rate. HPV16/18 + triage was the next most sensitive strategy (64.1%; 95% CI, 51.1%-75.7%). Low-grade squamous intraepithelial lesion or worse cytology (LSIL + ) triage yielded a low sensitivity (32.8%; 95% CI, 21.9%-45.4%) but had the most favorable specificity (93.6%; 95% CI, 91.0%-95.6%), positive predictive value (41.5%; 95% CI, 28.1%-55.9%), and colposcopy referral rate of strategies examined. HPV viral load triage strategies did not perform optimally overall. Inclusion of HR-HPV genotypes 31 and 52 to HPV16/18 + triage provided the highest sensitivities. Conclusion: Concerns surrounding HPV-based screening can be effectively mitigated via triage. Impact: Balancing the benefits of HPV-based primary cervical screening with informed management recommendations for HR-HPV + women may decide the success of its widening utilization. Cancer Epidemiol Biomarkers Prev; 26(6); 923-9. ©2017 AACR . ©2017 American Association for Cancer Research.

  4. Impact of normalization methods on high-throughput screening data with high hit rates and drug testing with dose-response data.

    PubMed

    Mpindi, John-Patrick; Swapnil, Potdar; Dmitrii, Bychkov; Jani, Saarela; Saeed, Khalid; Wennerberg, Krister; Aittokallio, Tero; Östling, Päivi; Kallioniemi, Olli

    2015-12-01

    Most data analysis tools for high-throughput screening (HTS) seek to uncover interesting hits for further analysis. They typically assume a low hit rate per plate. Hit rates can be dramatically higher in secondary screening, RNAi screening and in drug sensitivity testing using biologically active drugs. In particular, drug sensitivity testing on primary cells is often based on dose-response experiments, which pose a more stringent requirement for data quality and for intra- and inter-plate variation. Here, we compared common plate normalization and noise-reduction methods, including the B-score and the Loess a local polynomial fit method under high hit-rate scenarios of drug sensitivity testing. We generated simulated 384-well plate HTS datasets, each with 71 plates having a range of 20 (5%) to 160 (42%) hits per plate, with controls placed either at the edge of the plates or in a scattered configuration. We identified 20% (77/384) as the critical hit-rate after which the normalizations started to perform poorly. Results from real drug testing experiments supported this estimation. In particular, the B-score resulted in incorrect normalization of high hit-rate plates, leading to poor data quality, which could be attributed to its dependency on the median polish algorithm. We conclude that a combination of a scattered layout of controls per plate and normalization using a polynomial least squares fit method, such as Loess helps to reduce column, row and edge effects in HTS experiments with high hit-rates and is optimal for generating accurate dose-response curves. john.mpindi@helsinki.fi. Supplementary information: R code and Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press.

  5. Evaluation of ALK gene rearrangement in central nervous system metastases of non-small-cell lung cancer using two-step RT-PCR technique.

    PubMed

    Nicoś, M; Krawczyk, P; Wojas-Krawczyk, K; Bożyk, A; Jarosz, B; Sawicki, M; Trojanowski, T; Milanowski, J

    2017-12-01

    RT-PCR technique has showed a promising value as pre-screening method for detection of mRNA containing abnormal ALK sequences, but its sensitivity and specificity is still discussable. Previously, we determined the incidence of ALK rearrangement in CNS metastases of NSCLC using IHC and FISH methods. We evaluated ALK gene rearrangement using two-step RT-PCR method with EML4-ALK Fusion Gene Detection Kit (Entrogen, USA). The studied group included 145 patients (45 females, 100 males) with CNS metastases of NSCLC and was heterogeneous in terms of histology and smoking status. 21% of CNS metastases of NSCLC (30/145) showed presence of mRNA containing abnormal ALK sequences. FISH and IHC tests confirmed the presence of ALK gene rearrangement and expression of ALK abnormal protein in seven patients with positive result of RT-PCR analysis (4.8% of all patients, 20% of RT-PCR positive patients). RT-PCR method compared to FISH analysis achieved 100% of sensitivity and only 82.7% of specificity. IHC method compared to FISH method indicated 100% of sensitivity and 97.8% of specificity. In comparison to IHC, RT-PCR showed identical sensitivity with high number of false positive results. Utility of RT-PCR technique in screening of ALK abnormalities and in qualification patients for molecularly targeted therapies needs further validation.

  6. Evaluation of the Premi Test and comparison with the One-Plate Test for the detection of antimicrobials in kidney.

    PubMed

    Cantwell, H; O'Keeffe, M

    2006-02-01

    The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.

  7. A low density microarray method for the identification of human papillomavirus type 18 variants.

    PubMed

    Meza-Menchaca, Thuluz; Williams, John; Rodríguez-Estrada, Rocío B; García-Bravo, Aracely; Ramos-Ligonio, Ángel; López-Monteon, Aracely; Zepeda, Rossana C

    2013-09-26

    We describe a novel microarray based-method for the screening of oncogenic human papillomavirus 18 (HPV-18) molecular variants. Due to the fact that sequencing methodology may underestimate samples containing more than one variant we designed a specific and sensitive stacking DNA hybridization assay. This technology can be used to discriminate between three possible phylogenetic branches of HPV-18. Probes were attached covalently on glass slides and hybridized with single-stranded DNA targets. Prior to hybridization with the probes, the target strands were pre-annealed with the three auxiliary contiguous oligonucleotides flanking the target sequences. Screening HPV-18 positive cell lines and cervical samples were used to evaluate the performance of this HPV DNA microarray. Our results demonstrate that the HPV-18's variants hybridized specifically to probes, with no detection of unspecific signals. Specific probes successfully reveal detectable point mutations in these variants. The present DNA oligoarray system can be used as a reliable, sensitive and specific method for HPV-18 variant screening. Furthermore, this simple assay allows the use of inexpensive equipment, making it accessible in resource-poor settings.

  8. A Low Density Microarray Method for the Identification of Human Papillomavirus Type 18 Variants

    PubMed Central

    Meza-Menchaca, Thuluz; Williams, John; Rodríguez-Estrada, Rocío B.; García-Bravo, Aracely; Ramos-Ligonio, Ángel; López-Monteon, Aracely; Zepeda, Rossana C.

    2013-01-01

    We describe a novel microarray based-method for the screening of oncogenic human papillomavirus 18 (HPV-18) molecular variants. Due to the fact that sequencing methodology may underestimate samples containing more than one variant we designed a specific and sensitive stacking DNA hybridization assay. This technology can be used to discriminate between three possible phylogenetic branches of HPV-18. Probes were attached covalently on glass slides and hybridized with single-stranded DNA targets. Prior to hybridization with the probes, the target strands were pre-annealed with the three auxiliary contiguous oligonucleotides flanking the target sequences. Screening HPV-18 positive cell lines and cervical samples were used to evaluate the performance of this HPV DNA microarray. Our results demonstrate that the HPV-18's variants hybridized specifically to probes, with no detection of unspecific signals. Specific probes successfully reveal detectable point mutations in these variants. The present DNA oligoarray system can be used as a reliable, sensitive and specific method for HPV-18 variant screening. Furthermore, this simple assay allows the use of inexpensive equipment, making it accessible in resource-poor settings. PMID:24077317

  9. Shifted Transversal Design smart-pooling for high coverage interactome mapping

    PubMed Central

    Xin, Xiaofeng; Rual, Jean-François; Hirozane-Kishikawa, Tomoko; Hill, David E.; Vidal, Marc; Boone, Charles; Thierry-Mieg, Nicolas

    2009-01-01

    “Smart-pooling,” in which test reagents are multiplexed in a highly redundant manner, is a promising strategy for achieving high efficiency, sensitivity, and specificity in systems-level projects. However, previous applications relied on low redundancy designs that do not leverage the full potential of smart-pooling, and more powerful theoretical constructions, such as the Shifted Transversal Design (STD), lack experimental validation. Here we evaluate STD smart-pooling in yeast two-hybrid (Y2H) interactome mapping. We employed two STD designs and two established methods to perform ORFeome-wide Y2H screens with 12 baits. We found that STD pooling achieves similar levels of sensitivity and specificity as one-on-one array-based Y2H, while the costs and workloads are divided by three. The screening-sequencing approach is the most cost- and labor-efficient, yet STD identifies about twofold more interactions. Screening-sequencing remains an appropriate method for quickly producing low-coverage interactomes, while STD pooling appears as the method of choice for obtaining maps with higher coverage. PMID:19447967

  10. A high-throughput liquid bead array-based screening technology for Bt presence in GMO manipulation.

    PubMed

    Fu, Wei; Wang, Huiyu; Wang, Chenguang; Mei, Lin; Lin, Xiangmei; Han, Xueqing; Zhu, Shuifang

    2016-03-15

    The number of species and planting areas of genetically modified organisms (GMOs) has been rapidly developed during the past ten years. For the purpose of GMO inspection, quarantine and manipulation, we have now devised a high-throughput Bt-based GMOs screening method based on the liquid bead array. This novel method is based on the direct competitive recognition between biotinylated antibodies and beads-coupled antigens, searching for Bt presence in samples if it contains Bt Cry1 Aa, Bt Cry1 Ab, Bt Cry1 Ac, Bt Cry1 Ah, Bt Cry1 B, Bt Cry1 C, Bt Cry1 F, Bt Cry2 A, Bt Cry3 or Bt Cry9 C. Our method has a wide GMO species coverage so that more than 90% of the whole commercialized GMO species can be identified throughout the world. Under our optimization, specificity, sensitivity, repeatability and availability validation, the method shows a high specificity and 10-50 ng/mL sensitivity of quantification. We then assessed more than 1800 samples in the field and food market to prove capacity of our method in performing a high throughput screening work for GMO manipulation. Our method offers an applicant platform for further inspection and research on GMO plants. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  12. Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs

    NASA Astrophysics Data System (ADS)

    Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle

    2015-07-01

    Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.

  13. Comparison of different screening methods for blood pressure disorders in children and adolescents.

    PubMed

    Mourato, Felipe Alves; Lima Filho, José Luiz; Mattos, Sandra da Silva

    2015-01-01

    To compare different methods of screening for blood pressure disorders in children and adolescents. A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Influence of personal characteristics of individual women on sensitivity and specificity of mammography in the Million Women Study: cohort study

    PubMed Central

    Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta

    2004-01-01

    Objectives To examine how lifestyle, hormonal, and other factors influence the sensitivity and specificity of mammography. Methods Women recruited into the Million Women Study completed a questionnaire about various personal factors before routine mammographic screening. A sample of 122 355 women aged 50-64 years were followed for outcome of screening and incident breast cancer in the next 12 months. Sensitivity and specificity were calculated by using standard definitions, with adjustment for potential confounding factors. Results Breast cancer was diagnosed in 726 (0.6%) women, 629 in screen positive and 97 in screen negative women; 3885 (3.2%) were screen positive but had no subsequent diagnosis of breast cancer. Overall sensitivity was 86.6% and specificity was 96.8%. Three factors had an adverse effect on both measures: use of hormone replacement therapy (sensitivity: 83.0% (95% confidence interval 77.4% to 87.6%), 84.7% (73.9% to 91.6%), and 92.1% (87.6% to 95.0%); specificity: 96.8% (96.6% to 97.0%), 97.8% (97.5% to 98.0%), and 98.1% (98.0% to 98.2%), respectively, for current, past, and never use); previous breast surgery v no previous breast surgery (sensitivity: 83.5% (75.7% to 89.1%) v 89.4% (86.5% to 91.8%); specificity: 96.2% (95.8% to 96.5%) v 97.4% (97.3% to 97.5%), respectively); and body mass index < 25 v ≥ 25 (sensitivity: 85.7% (81.2% to 89.3%) v 91.0% (87.5% to 93.6%); specificity: 97.2% (97.0% to 97.3%) v 97.4% (97.3% to 97.6%), respectively). Neither sensitivity nor specificity varied significantly according to age, family history of breast cancer, parity, past oral contraceptive use, tubal ligation, physical activity, smoking, or alcohol consumption. Conclusions The efficiency, and possibly the effectiveness, of mammographic screening is lower in users of hormone replacement therapy, in women with previous breast surgery, and in thin women compared with other women. PMID:15331472

  15. Tension fracture of laminates for transport fuselage. Part 1: Material screening

    NASA Technical Reports Server (NTRS)

    Walker, T. H.; Avery, W. B.; Ilcewicz, L. B.; Poe, C. C., Jr.; Harris, C. E.

    1992-01-01

    Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Applications of composites to fuselage structures require a database and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity; (2) evaluate composite failure criteria; and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in major load bearing plies. Parameters for conventional fracture criteria were found to increase with crack length for the smallest notch sizes studied. Most material and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Traitional methods of correcting for specimen finite width were found to be lacking. Results indicate that a range of notch sizes must be tested to determine notch sensitivity. Data for a single small notch size (0.25 in. diameter) was found to give no indication of the sensitivity of a particular material and laminate layup to larger notch sizes.

  16. Sensitivity of nested-PCR for plasmodium detection in pooled whole blood samples and its usefulness to blood donor screening in endemic areas.

    PubMed

    de Freitas, Daniel Roberto Coradi; Gomes, Luciano Teixeira; Fontes, Cor Jesus F; Tauil, Pedro Luiz; Pang, Lorrin W; Duarte, Elisabeth Carmen

    2014-04-01

    Transfusion-transmitted malaria is a severe disease with high fatality rate. Most Brazilian blood banks in the Amazon region perform malaria screening using microscopic examination (thick smears). Since low parasite concentrations are expected in asymptomatic blood donors a high sensitivity test should be used for donor screening. This study determined the sensitivity of a nested-PCR for plasmodium detection in pooled samples. We performed a one-stage criterion validation study with 21 positive samples pooled with samples from ten negative volunteer until three different concentrations were reached (0.33; 0.25; 0.20 parasites/μL - p/μL). Nested PCR was performed as described by Snounou et al. (1993). Sensitivities (and confidence intervals) were determined by stratum of final parasite concentration on the pooled samples. All samples with parasitemia values of 0.33 and 0.25 p/μL had 100% sensitivity (95%CI=86.3-100). One negative result was obtained from a sample with 0.20 p/μL sensitivity=95.2% (95%CI=76.2-99.9). Compared to parasitemia detectable under ideal conditions of thick smear, this nested-PCR in pooled sample was able to detect 40 times more parasites per microliter. Nested-PCR in pooled samples should be considered as a high sensitive alternative to thick smear for donor screening in blood banks at endemic regions. Local authorities need to assess cost:benefit advantages of this method compared to alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Lead screening in DBS by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry: application to newborns and pregnant women.

    PubMed

    Rello, Luis; Aramendía, Maite; Belarra, Miguel A; Resano, Martín

    2015-01-01

    DBS have become a clinical specimen especially adequate for establishing home-based collection protocols. In this work, high-resolution continuum source graphite furnace atomic absorption spectrometry is evaluated for the direct monitoring of Pb in DBS, both as a quantitative tool and a screening method. The development of the screening model is based on the establishment of the unreliability region around the threshold limits, 100 or 50 μg l(-1). More than 500 samples were analyzed to validate the model. The screening method demonstrated high sensitivity (the rate of true positives detected was always higher than 95%), an excellent LOD (1 µg l(-1)) and high throughput (10 min per sample).

  18. Fecal occult blood testing beliefs and practices of U.S. primary care physicians: serious deviations from evidence-based recommendations.

    PubMed

    Nadel, Marion R; Berkowitz, Zahava; Klabunde, Carrie N; Smith, Robert A; Coughlin, Steven S; White, Mary C

    2010-08-01

    Fecal occult blood testing (FOBT) is an important option for colorectal cancer screening that should be available in order to achieve high population screening coverage. However, results from a national survey of clinical practice in 1999-2000 indicated that many primary care physicians used inadequate methods to implement FOBT screening and follow-up. To determine whether methods to screen for fecal occult blood have improved, including the use of newer more sensitive stool tests. Cross-sectional national survey of primary care physicians. Participants consisted of 1,134 primary care physicians who reported ordering or performing FOBT in the 2006-2007 National Survey of Primary Care Physicians' Recommendations and Practices for Cancer Screening. Self-reported data on details of FOBT implementation and follow-up of positive results. Most physicians report using standard guaiac tests; higher sensitivity guaiac tests and immunochemical tests were reported by only 22.0% and 8.9%, respectively. In-office testing, that is, testing of a single specimen collected during a digital rectal examination in the office, is still widely used although inappropriate for screening: 24.9% of physicians report using only in-office tests and another 52.9% report using both in-office and home tests. Recommendations improved for follow-up after a positive test: fewer physicians recommend repeating the FOBT (17.8%) or using tests other than colonoscopy for the diagnostic work-up (6.6%). Only 44.3% of physicians who use home tests have reminder systems to ensure test completion and return. Many physicians continue to use inappropriate methods to screen for fecal occult blood. Intensified efforts to inform physicians of recommended technique and promote the use of tracking systems are needed.

  19. The PHQ-PD as a Screening Tool for Panic Disorder in the Primary Care Setting in Spain

    PubMed Central

    Wood, Cristina Mae; Ruíz-Rodríguez, Paloma; Tomás-Tomás, Patricia; Gracia-Gracia, Irene; Dongil-Collado, Esperanza; Iruarrizaga, M. Iciar

    2016-01-01

    Introduction Panic disorder is a common anxiety disorder and is highly prevalent in Spanish primary care centres. The use of validated tools can improve the detection of panic disorder in primary care populations, thus enabling referral for specialized treatment. The aim of this study is to determine the accuracy of the Patient Health Questionnaire-Panic Disorder (PHQ-PD) as a screening and diagnostic tool for panic disorder in Spanish primary care centres. Method We compared the psychometric properties of the PHQ-PD to the reference standard, the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview. General practitioners referred 178 patients who completed the entire PHQ test, including the PHQ-PD, to undergo the SCID-I. The sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios of the PHQ-PD were assessed. Results The operating characteristics of the PHQ-PD are moderate. The best cut-off score was 5 (sensitivity .77, specificity .72). Modifications to the questionnaire's algorithms improved test characteristics (sensitivity .77, specificity .72) compared to the original algorithm. The screening question alone yielded the highest sensitivity score (.83). Conclusion Although the modified algorithm of the PHQ-PD only yielded moderate results as a diagnostic test for panic disorder, it was better than the original. Using only the first question of the PHQ-PD showed the best psychometric properties (sensitivity). Based on these findings, we suggest the use of the screening questions for screening purposes and the modified algorithm for diagnostic purposes. PMID:27525977

  20. [New intensifying screens in clinical radiology. II. Examinations in clinical practice].

    PubMed

    Freyschmidt, J; Saure, D; Hagemann, G

    1976-09-01

    A clinically applicable procedure for testing new intensifying rare earth screens, as well as the special Siemens' screen is described. The results are related to universal screens. The film-screen combination alpha 4XD (gadolinium oxysulphide with normal, green sensitive film) results in a reduction of radiation dose to half with detail comparable with universal screens. The Siemens' special screen has similar advantages. Screens with a higher intensification factor and reduction of the mAs to one sixth results in loss of detail. This does not necessarily reduce their clinical use if they are used for appropriate purposes. The results of this clinically orientated technique agreed well with physically objective methods using lead grids. The advantages of the new screens are discussed in terms of their practical application.

  1. Using the Center for Epidemiologic Studies Depression Scale to Screen for Depression in Systemic Lupus Erythematosus

    PubMed Central

    Julian, Laura J.; Gregorich, Steven E.; Tonner, Chris; Yazdany, Jinoos; Trupin, Laura; Criswell, Lindsey A.; Yelin, ED; Katz, Patricia P.

    2013-01-01

    Objective Identifying persons with systemic lupus erythematosus (SLE) at risk for depression would facilitate the identification and treatment of an important comorbidity conferring additional risk for poor outcomes. The purpose of this study was to determine the utility of a brief screening measure, the Center for Epidemiologic Studies Depression Scale (CES-D), in detecting mood disorders in persons with SLE. Methods This cross-sectional study examined 150 persons with SLE. Screening cut points were empirically derived using threshold selection methods, and receiver operating characteristic curves were estimated. The empirically derived cut points of the CES-D were used as the screening measures and were compared to other commonly used CES-D cut points in addition to other commonly used methods to screen for depression. Diagnoses of major depressive disorder or other mood disorders were determined using a “gold standard” structured clinical interview. Results Of the 150 persons with SLE, 26% of subjects met criteria for any mood disorder and 17% met criteria for major depressive disorder. Optimal threshold estimations suggested a CES-D cut score of 24 and above, which yielded adequate sensitivity and specificity in detecting major depressive disorder (88% and 93%, respectively) and correctly classified 92% of participants. To detect the presence of any mood disorder, a cut score of 20 and above was suggested, yielding sensitivity and specificity of 87% and correctly classifying 87%. Conclusion These results suggest the CES-D may be a useful screening measure to identify patients at risk for depression. PMID:21312347

  2. Colorimetry and SERS dual-mode detection of telomerase activity: combining rapid screening with high sensitivity

    NASA Astrophysics Data System (ADS)

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping

    2014-01-01

    As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis. Electronic supplementary information (ESI) available: TEM images of individual MB@Au NPs, results of dynamic light scattering analysis and extinction spectrum obtained using colorimetry detection. See DOI: 10.1039/c3nr04942f

  3. Prospective evaluation of methylated SEPT9 in plasma for detection of asymptomatic colorectal cancer

    PubMed Central

    Church, Timothy Robert; Wandell, Michael; Lofton-Day, Catherine; Mongin, Steven J; Burger, Matthias; Payne, Shannon R; Castaños-Vélez, Esmeralda; Blumenstein, Brent A; Rösch, Thomas; Osborn, Neal; Snover, Dale; Day, Robert W; Ransohoff, David F

    2014-01-01

    Background As screening methods for colorectal cancer (CRC) are limited by uptake and adherence, further options are sought. A blood test might increase both, but none has yet been tested in a screening setting. Objective We prospectively assessed the accuracy of circulating methylated SEPT9 DNA (mSEPT9) for detecting CRC in a screening population. Design Asymptomatic individuals ≥50 years old scheduled for screening colonoscopy at 32 US and German clinics voluntarily gave blood plasma samples before colon preparation. Using a commercially available assay, three independent blinded laboratories assayed plasma DNA of all CRC cases and a stratified random sample of other subjects in duplicate real time PCRs. The primary outcomes measures were standardised for overall sensitivity and specificity estimates. Results 7941 men (45%) and women (55%), mean age 60 years, enrolled. Results from 53 CRC cases and from 1457 subjects without CRC yielded a standardised sensitivity of 48.2% (95% CI 32.4% to 63.6%; crude rate 50.9%); for CRC stages I–IV, values were 35.0%, 63.0%, 46.0% and 77.4%, respectively. Specificity was 91.5% (95% CI 89.7% to 93.1%; crude rate 91.4%). Sensitivity for advanced adenomas was low (11.2%). Conclusions Our study using the blood based mSEPT9 test showed that CRC signal in blood can be detected in asymptomatic average risk individuals undergoing screening. However, the utility of the test for population screening for CRC will require improved sensitivity for detection of early cancers and advanced adenomas. Clinical Trial Registration Number: NCT00855348 PMID:23408352

  4. Classification and virtual screening of androgen receptor antagonists.

    PubMed

    Li, Jiazhong; Gramatica, Paola

    2010-05-24

    Computational tools, such as quantitative structure-activity relationship (QSAR), are highly useful as screening support for prioritization of substances of very high concern (SVHC). From the practical point of view, QSAR models should be effective to pick out more active rather than inactive compounds, expressed as sensitivity in classification works. This research investigates the classification of a big data set of endocrine-disrupting chemicals (EDCs)-androgen receptor (AR) antagonists, mainly aiming to improve the external sensitivity and to screen for potential AR binders. The kNN, lazy IB1, and ADTree methods and the consensus approach were used to build different models, which improve the sensitivity on external chemicals from 57.1% (literature) to 76.4%. Additionally, the models' predictive abilities were further validated on a blind collected data set (sensitivity: 85.7%). Then the proposed classifiers were used: (i) to distinguish a set of AR binders into antagonists and agonists; (ii) to screen a combined estrogen receptor binder database to find out possible chemicals that can bind to both AR and ER; and (iii) to virtually screen our in-house environmental chemical database. The in silico screening results suggest: (i) that some compounds can affect the normal endocrine system through a complex mechanism binding both to ER and AR; (ii) new EDCs, which are nonER binders, but can in silico bind to AR, are recognized; and (iii) about 20% of compounds in a big data set of environmental chemicals are predicted as new AR antagonists. The priority should be given to them to experimentally test the binding activities with AR.

  5. A quartz-based micro catalytic methane sensor by high resolution screen printing

    NASA Astrophysics Data System (ADS)

    Lu, Wenshuai; Jing, Gaoshan; Bian, Xiaomeng; Yu, Hongyan; Cui, Tianhong

    2016-02-01

    A micro catalytic methane sensor was proposed and fabricated on a bulk fused quartz substrate using a high resolution screen printing technique for the first time, with reduced power consumption and optimized sensitivity. The sensor was designed by the finite element method and quartz was chosen as the substrate material and alumina support with optimized dimensions. Fabrication of the sensor consisted of two MEMS processes, lift-off and high resolution screen printing, with the advantages of high yield and uniformity. When the sensor’s regional working temperature changes from 250 °C to 470 °C, its sensitivity increases, as well as the power consumption. The highest sensitivity can reach 1.52 mV/% CH4. A temperature of 300 °C was chosen as the optimized working temperature, and the sensor’s sensitivity, power consumption, nonlinearity and response time are 0.77 mV/% CH4, 415 mW, 2.6%, and 35 s, respectively. This simple, but highly uniform fabrication process and the reliable performance of this sensor may lead to wide applications for methane detection.

  6. Efficient exploration of chemical space by fragment-based screening.

    PubMed

    Hall, Richard J; Mortenson, Paul N; Murray, Christopher W

    2014-01-01

    Screening methods seek to sample a vast chemical space in order to identify starting points for further chemical optimisation. Fragment based drug discovery exploits the superior sampling of chemical space that can be achieved when the molecular weight is restricted. Here we show that commercially available fragment space is still relatively poorly sampled and argue for highly sensitive screening methods to allow the detection of smaller fragments. We analyse the properties of our fragment library versus the properties of X-ray hits derived from the library. We particularly consider properties related to the degree of planarity of the fragments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Evaluation of different methods to detect methicillin resistance in Staphylococcus aureus (MRSA).

    PubMed

    Alipour, Farzad; Ahmadi, Malahat; Javadi, Shahram

    2014-01-01

    The studies suggest that dogs living with human are potential risk of becoming MRSA carrier and increased risk of infections caused by MRSA. Phenotypic methods to detect methicillin resistance in Staphylococcus aureus (MRSA) are inadequate. The objective of the present study was to determine methicillin resistance in S. aureus by phenotypic susceptibility test (oxacillin disk diffusion, cefoxitin disk diffusion, oxacillin screen agar) and molecular methods (PCR as a gold standard) and the latex agglutination test for the detection of PBP2a and to evaluate the results of these tests for its sensitivity and specificity. A total of 100 swab samples were taken from muzzle site, in more contact with human, of dogs and MRSA were isolated. Oxacillin (1 μg), cefoxitin (30 μg) disk diffusion and oxacillin screen agar method were used. The isolates were also subjected to latex agglutination test for detection of PBP2a and PCR to detect mecA gene. By PCR 37% of isolates show the presence of mecA. Latex agglutination was found to be the most sensitive (97.29%) and cefoxitin disk diffusion to be the most specific (96.82%) tests for detection of MRSA. Our finding showed that combining oxacillin screen agar or cefoxitin disk diffusion with latex agglutination improves sensitivity and specificity to detect methicillin resistance S. aureus (MRSA) isolates. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  8. Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.

    PubMed

    Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M

    1997-06-01

    To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of screening. Advantages of the IRT/DNA protocol over IRT analysis include improved positive predictive value, reduction of false-positive infants, and more rapid diagnosis with elimination of recall specimens.

  9. Fragment length analysis screening for detection of CEBPA mutations in intermediate-risk karyotype acute myeloid leukemia.

    PubMed

    Fuster, Oscar; Barragán, Eva; Bolufer, Pascual; Such, Esperanza; Valencia, Ana; Ibáñez, Mariam; Dolz, Sandra; de Juan, Inmaculada; Jiménez, Antonio; Gómez, Maria Teresa; Buño, Ismael; Martínez, Joaquín; Cervera, José; Montesinos, Pau; Moscardó, Federico; Sanz, Miguel Ángel

    2012-01-01

    During last years, molecular markers have been increased as prognostic factors routinely screened in acute myeloid leukemia (AML). Recently, an increasing interest has been reported in introducing to clinical practice screening for mutations in the CCAAT/enhancer-binding protein α (CEBPA) gene in AML, as it seems to be a good prognostic factor. However, there is no reliable established method for assessing CEBPA mutations during the diagnostic work-up of AMLs. We describe here a straightforward and reliable fragment analysis method based in PCR capillary electrophoresis (PCR-CE) for screening of CEBPA mutations; moreover, we present the results obtained in 151 intermediate-risk karyotype AML patients (aged 16-80 years). The method gave a specificity of 100% and sensitivity of 93% with a lower detection limit of 1-5% for CEBPA mutations. The series found 19 mutations and four polymorphisms in 12 patients, seven of whom (58%) presented two mutations. The overall frequency of CEBPA mutations in AML was 8% (n = 12). CEBPA mutations showed no coincidence with FLT3-ITD or NPM1 mutations. CEBPA mutation predicted better disease-free survival in the group of patients without FLT3-ITD, NPM, or both genes mutated (HR 3.6, IC 95%; 1.0-13.2, p = 0.05) and better overall survival in patients younger than 65 of this group without molecular markers (HR 4.0, IC 95%; 1.0-17.4, p = 0.05). In conclusion, the fragment analysis method based in PCR-CE is a rapid, specific, and sensitive method for CEBPA mutation screening and our results confirm that CEBPA mutations can identify a subgroup of patients with favorable prognosis in AML with intermediate-risk karyotype.

  10. Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.

    PubMed

    Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.

    2003-12-01

    OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.

  11. Screening DNA chip and event-specific multiplex PCR detection methods for biotech crops.

    PubMed

    Lee, Seong-Hun

    2014-11-01

    There are about 80 biotech crop events that have been approved by safety assessment in Korea. They have been controlled by genetically modified organism (GMO) and living modified organism (LMO) labeling systems. The DNA-based detection method has been used as an efficient scientific management tool. Recently, the multiplex polymerase chain reaction (PCR) and DNA chip have been developed as simultaneous detection methods for several biotech crops' events. The event-specific multiplex PCR method was developed to detect five biotech maize events: MIR604, Event 3272, LY 038, MON 88017 and DAS-59122-7. The specificity was confirmed and the sensitivity was 0.5%. The screening DNA chip was developed from four endogenous genes of soybean, maize, cotton and canola respectively along with two regulatory elements and seven genes: P35S, tNOS, pat, bar, epsps1, epsps2, pmi, cry1Ac and cry3B. The specificity was confirmed and the sensitivity was 0.5% for four crops' 12 events: one soybean, six maize, three cotton and two canola events. The multiplex PCR and DNA chip can be available for screening, gene-specific and event-specific analysis of biotech crops as efficient detection methods by saving on workload and time. © 2014 Society of Chemical Industry. © 2014 Society of Chemical Industry.

  12. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants.

    PubMed

    Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir

    2012-07-06

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10-11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary.

  13. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    PubMed Central

    Salazar, Carolina; Armenta, Jenny M.; Shulaev, Vladimir

    2012-01-01

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10−11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary. PMID:24957640

  14. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    PubMed

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  15. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  16. Evaluation of the GARD assay in a blind Cosmetics Europe study.

    PubMed

    Johansson, Henrik; Gradin, Robin; Forreryd, Andy; Agemark, Maria; Zeller, Kathrin; Johansson, Angelica; Larne, Olivia; van Vliet, Erwin; Borrebaeck, Carl; Lindstedt, Malin

    2017-01-01

    Chemical hypersensitivity is an immunological response towards foreign substances, commonly referred to as sensitizers, which gives rise primarily to the clinical symptoms known as allergic contact dermatitis. For the purpose of mitigating risks associated with consumer products, chemicals are screened for sensitizing effects. Historically, such predictive screenings have been performed using animal models. However, due to industrial and regulatory demand, animal models for the purpose of sensitization assessment are being replaced by non-animal testing methods, a global trend that is spreading across industries and market segments. To meet this demand, the Genomic Allergen Rapid Detection (GARD) assay was developed. GARD is a novel, cell-based assay that utilizes the innate recognition of xenobiotic substances by dendritic cells, as measured by a multivariate readout of genomic biomarkers. Following cellular stimulation, chemicals are classified as sensitizers or non-sensitizers based on induced transcriptional profiles. Recently, a number of non-animal methods were comparatively evaluated by Cosmetics Europe, using a coherent and blinded test panel of reference chemicals with human and local lymph node assay data, comprising a wide range of sensitizers and non-sensitizers. The outcome of the GARD assay is presented in this paper. It was demonstrated that GARD is a highly functional assay with a predictive performance of 83% in this Cosmetics Europe dataset. The average accumulated predictive accuracy of GARD across independent datasets was 86% for skin sensitization hazard.

  17. Nuclear morphology for the detection of alterations in bronchial cells from lung cancer: an attempt to improve sensitivity and specificity.

    PubMed

    Fafin-Lefevre, Mélanie; Morlais, Fabrice; Guittet, Lydia; Clin, Bénédicte; Launoy, Guy; Galateau-Sallé, Françoise; Plancoulaine, Benoît; Herlin, Paulette; Letourneux, Marc

    2011-08-01

    To identify which morphologic or densitometric parameters are modified in cell nuclei from bronchopulmonary cancer based on 18 parameters involving shape, intensity, chromatin, texture, and DNA content and develop a bronchopulmonary cancer screening method relying on analysis of sputum sample cell nuclei. A total of 25 sputum samples from controls and 22 bronchial aspiration samples from patients presenting with bronchopulmonary cancer who were professionally exposed to cancer were used. After Feulgen staining, 18 morphologic and DNA content parameters were measured on cell nuclei, via image cytom- etry. A method was developed for analyzing distribution quantiles, compared with simply interpreting mean values, to characterize morphologic modifications in cell nuclei. Distribution analysis of parameters enabled us to distinguish 13 of 18 parameters that demonstrated significant differences between controls and cancer cases. These parameters, used alone, enabled us to distinguish two population types, with both sensitivity and specificity > 70%. Three parameters offered 100% sensitivity and specificity. When mean values offered high sensitivity and specificity, comparable or higher sensitivity and specificity values were observed for at least one of the corresponding quantiles. Analysis of modification in morphologic parameters via distribution analysis proved promising for screening bronchopulmonary cancer from sputum.

  18. The validity of self-reported cancer screening history and the role of social disadvantage in Ontario, Canada.

    PubMed

    Lofters, Aisha; Vahabi, Mandana; Glazier, Richard H

    2015-01-29

    Self-report may not be an accurate method of determining cervical, breast and colorectal cancer screening rates due to recall, acquiescence and social desirability biases, particularly for certain sociodemographic groups. Therefore, the aims of this study were to determine the validity of self-report of cancer screening in Ontario, Canada, both for people in the general population and for socially disadvantaged groups based on immigrant status, ethnicity, education, income, language ability, self-rated health, employment status, age category (for cervical cancer screening), and gender (for fecal occult blood testing). We linked multiple data sources for this study, including the Canadian Community Health Survey and provincial-level health databases. Using administrative data as our gold standard, we calculated validity measures for self-report (i.e. sensitivity, specificity, positive and negative likelihood ratios, positive and negative predictive values), calculated report-to-record ratios, and conducted a multivariable regression analysis to determine which characteristics were independently associated with over-reporting of screening. Specificity was less than 70% overall and for all subgroups for cervical and breast cancer screening, and sensitivity was lower than 80% overall and for all subgroups for fecal occult blood testing FOBT. Report-to-record ratios were persistently significantly greater than 1 across all cancer screening types, highest for the FOBT group: 1.246 [1.189-1.306]. Regression analyses showed no consistent patterns, but sociodemographic characteristics were associated with over-reporting for each screening type. We have found that in Ontario, as in other jurisdictions, there is a pervasive tendency for people to over-report their cancer screening histories. Sociodemographic status also appears to influence over-reporting. Public health practitioners and policymakers need to be aware of the limitations of self-report and adjust their methods and interpretations accordingly.

  19. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    PubMed

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  20. An Independent Investigation of the Utility of the Learning Disability Screening Questionnaire (LDSQ) within a Community Learning Disability Team

    ERIC Educational Resources Information Center

    Stirk, Steven; Field, Bryony; Black, Jessica

    2018-01-01

    Background: The Learning Disability Screening Questionnaire (LDSQ) has been shown to have high sensitivity and specificity to identify those who are likely to meet intellectual disability diagnostic criteria (McKenzie, et al. [McKenzie K., 2015]). However, there is no independent research to date to support these findings. Materials and Methods:…

  1. Generation and Characterization of Environmentally Sensitive Variants of the β-Galactosidase from Lactobacillus delbrueckii subsp. bulgaricus

    PubMed Central

    Yoast, Sienna; Adams, Robin M.; Mainzer, Stanley E.; Moon, Keith; Palombella, Anthony L.; Schmidt, Brian F.

    1994-01-01

    A method is described for generating and screening variants of the β-galactosidase from Lactobacillus delbrueckii subsp. bulgaricus sensitive to several environmental stresses, with potential application in the food industry. Chemical mutagenesis with hydroxylamine or methoxylamine was performed on the β-galactosidase gene carried on an Escherichia coli expression vector. Mutants sensitive to cold, heat, low pH, low magnesium concentration, and the presence of urea were isolated by screening for reduced color development on β-galactosidase indicator plates. The mutations responsible for three variant β-galactosidases were localized, and the base substitutions were determined by DNA sequencing. The amino acid alterations associated with one low-pH-sensitive (pHs) and two urea-sensitive (Us) variants correspond to P584L (pHs1), G400S/R479Q (Us26), and G167E/E168K/E363K/V492M (Us17), respectively. Mutant pHs1 is also heat, cold, low magnesium, and urea sensitive; Us26 is also cold sensitive; and Us17 is also low-pH sensitive. PMID:16349230

  2. An EEG-based functional connectivity measure for automatic detection of alcohol use disorder.

    PubMed

    Mumtaz, Wajid; Saad, Mohamad Naufal B Mohamad; Kamel, Nidal; Ali, Syed Saad Azhar; Malik, Aamir Saeed

    2018-01-01

    The abnormal alcohol consumption could cause toxicity and could alter the human brain's structure and function, termed as alcohol used disorder (AUD). Unfortunately, the conventional screening methods for AUD patients are subjective and manual. Hence, to perform automatic screening of AUD patients, objective methods are needed. The electroencephalographic (EEG) data have been utilized to study the differences of brain signals between alcoholics and healthy controls that could further developed as an automatic screening tool for alcoholics. In this work, resting-state EEG-derived features were utilized as input data to the proposed feature selection and classification method. The aim was to perform automatic classification of AUD patients and healthy controls. The validation of the proposed method involved real-EEG data acquired from 30 AUD patients and 30 age-matched healthy controls. The resting-state EEG-derived features such as synchronization likelihood (SL) were computed involving 19 scalp locations resulted into 513 features. Furthermore, the features were rank-ordered to select the most discriminant features involving a rank-based feature selection method according to a criterion, i.e., receiver operating characteristics (ROC). Consequently, a reduced set of most discriminant features was identified and utilized further during classification of AUD patients and healthy controls. In this study, three different classification models such as Support Vector Machine (SVM), Naïve Bayesian (NB), and Logistic Regression (LR) were used. The study resulted into SVM classification accuracy=98%, sensitivity=99.9%, specificity=95%, and f-measure=0.97; LR classification accuracy=91.7%, sensitivity=86.66%, specificity=96.6%, and f-measure=0.90; NB classification accuracy=93.6%, sensitivity=100%, specificity=87.9%, and f-measure=0.95. The SL features could be utilized as objective markers to screen the AUD patients and healthy controls. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Cost-effectiveness analysis of colorectal cancer screening methods in Iran.

    PubMed

    Allameh, Zahra; Davari, Majid; Emami, Mohammad Hasan

    2011-03-01

    Screening can prevent colorectal cancer from becoming advanced by early detection of precancerous lesions. Cost-effectiveness analysis of colorectal cancer screening methods is highly necessary due to increased prevalence, decreased age at onset and the limited budget in Iran. Methods of screening currently available in Iran were selected. A systematic search revealed the sensitivity and specificity of each method. For this study, a model for a 20 year screening period of a population of 100,000 apparently healthy persons of ages 45-65 years in Isfahan Province was used. The cost-effectiveness of each method and the ratio of cost-effectiveness were calculated based on this model. The most and the least effective methods were CT colonography and fecal occult blood test, respectively. The highest and lowest expenditures in the governmental sector were related to fecal occult blood test and flexible sigmoidoscopy and in the private sector, to CT colonography and fecal occult blood test, respectively. The cost per cancer detected in 20 years of screening in the governmental sector was 0.28, 0.22 and 0.42 billion Rials, respectively for screening by colonoscopy, flexible sigmoidoscopy and fecal occult blood test. In the private sector, these were 1.54 (colonoscopy), 1.68 (flexible sigmoidoscopy), and 1.60 (fecal occult blood test) billion and 2.58 billion Rials for CT colonography, respectively. Although CT colonography is the most effective method, it needs a budget of 2.58 billion Rials for each screened patient. If costs in the governmental sector are considered, flexible sigmoidoscopy would be the most cost-effective method for screening the 45 - 65-year-old population in Iran.

  4. Does Assessing Eye Alignment along with Refractive Error or Visual Acuity Increase Sensitivity for Detection of Strabismus in Preschool Vision Screening?

    PubMed Central

    2007-01-01

    Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881

  5. A preliminary cost-effectiveness analysis of hepatitis E vaccination among pregnant women in epidemic regions.

    PubMed

    Zhao, Yueyuan; Zhang, Xuefeng; Zhu, Fengcai; Jin, Hui; Wang, Bei

    2016-08-02

    Objective To estimate the cost-effectiveness of hepatitis E vaccination among pregnant women in epidemic regions. Methods A decision tree model was constructed to evaluate the cost-effectiveness of 3 hepatitis E virus vaccination strategies from societal perspectives. The model parameters were estimated on the basis of published studies and experts' experience. Sensitivity analysis was used to evaluate the uncertainties of the model. Results Vaccination was more economically effective on the basis of the incremental cost-effectiveness ratio (ICER< 3 times China's per capital gross domestic product/quality-adjusted life years); moreover, screening and vaccination had higher QALYs and lower costs compared with universal vaccination. No parameters significantly impacted ICER in one-way sensitivity analysis, and probabilistic sensitivity analysis also showed screening and vaccination to be the dominant strategy. Conclusion Screening and vaccination is the most economical strategy for pregnant women in epidemic regions; however, further studies are necessary to confirm the efficacy and safety of the hepatitis E vaccines.

  6. Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.

    PubMed

    Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S

    2012-01-01

    Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.

  7. [Value of Immunohistochemical Methods in Detecting EML4-ALK Fusion Mutations: A Meta-analysis].

    PubMed

    Liu, Chang; Cai, Lu; Zhong, Diansheng; Wang, Jing

    2016-01-01

    The fusion between echinoderm microtubule-associated protein 4 (EML4) and anaplastic lymphatic tumor kinase (ALK) rearrangement is present in approximately 5% of non-small cell lung cancer (NSCLC) patients. It has been regarded as another new target gene after epidermal growth factor receptor (EGFR) and K-ras. Figures showed that the disease control rate could reach up to 80% in NSCLC patients with EML4-ALK fusion gene after treated with ALK inhibitors. Thus, exploring an accurate and rapid detecting method is the key in screening NSCLC patients with EML4-ALK expressions. The aim of this study is to analyze the specificity and sensitivity of IHC in detecting EML4-ALK fusion mutations. To evaluate the accuracy and clinical value of this method, and then provide basis for individual molecular therapy of NSCLC patients. Using Pubmed database to search all documents required. The deadline of retrieval was February 25, 2015. Then further screening the articles according to the inclusion and exclusion criteria. Using diagnostic test meta-analysis methods to analyze the sensitivity and specificity of the immunohistochemistry (IHC) method compared with fluorescence in situ hybridization (FISH) method. Eleven literatures were added into the meta analysis, there were 3,234 of total cases. The diagnostic odds ratio (DOR) was 1,135.00 (95%CI: 337.10-3,821.46); the area under curve (AUC) of summary receiver operating characteristic curve (SROC) curve was 0.992,3 (SEAUC=0.003,2), the Q* was 0.964,4 (SEQ*=0.008,7). Immunohistochemical detection of EML4-ALK fusion gene mutation with specific antibody is feasible. It has high sensitivity and specificity. IHC can be a simple and rapid way in screening EML4-ALK fusion gene mutation and exhibits important clinical values.

  8. Plasma Septin9 versus Fecal Immunochemical Testing for Colorectal Cancer Screening: A Prospective Multicenter Study

    PubMed Central

    Johnson, David A.; Barclay, Robert L.; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T.

    2014-01-01

    Background Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. Objective To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. Design: In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Measurements Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. Results For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9–80.9%) and 68.0% (95% CI 58.2–76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5–86.3%) compared with 97.4% (95% CI 94.1–98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% –95% CI 62.5–80.1%) was shown to be statistically non-inferior to FIT (68.0%–95% CI 58.2–76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. Conclusions At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. Trial Registration ClinicalTrials.gov NCT01580540 PMID:24901436

  9. Criteria To Screen for Chronic Sinonasal Disease

    PubMed Central

    Dixon, Anne E.; Sugar, Elizabeth A.; Zinreich, S. James; Slavin, Raymond G.; Corren, Jonathan; Naclerio, Robert M.; Ishii, Masaru; Cohen, Rubin I.; Brown, Ellen D.; Wise, Robert A.; Irvin, Charles G.

    2009-01-01

    Background: Sinusitis and rhinitis are associated with uncontrolled asthma. There are no simple, validated tools to screen for these diseases. The objective of this study was to assess instruments to assist in the diagnosis of chronic sinonasal disease. Methods: Participants without acute sinonasal symptoms underwent an extensive evaluation. The results were submitted to an expert panel that used the Delphi method to achieve consensus. Using the consensus diagnosis of the panel, we determined the sensitivity and specificity of test procedures to diagnose chronic sinonasal disease. We determined the reproducibility of the most sensitive and specific instrument in a separate cohort. Results: Fifty-nine participants were evaluated, and the expert panel reached consensus for all (42 participants with chronic sinonasal disease, 17 participants without chronic sinonasal disease). A six-item questionnaire based on the frequency of nasal symptoms was the most sensitive tool used to diagnose sinonasal disease (minimum specificity, 0.90). Reproducibility testing in a separate cohort of 63 participants (41 chronic sinonasal disease with asthma, 22 chronic sinonasal disease without asthma) showed a concordance correlation coefficient of 0.91 (95% CI, 0.85 to 0.94) when this questionnaire was limited to five items (ie, excluding a question on smell). This five-item questionnaire had a sensitivity of 0.90 (95% CI, 0.77 to 0.97), a specificity of 0.94 (95% CI, 0.71 to 1.00), and an area under the receiver operating characteristic curve of 0.97 (95% CI, 0.93 to 1.0). Sinus CT scans and nasal endoscopy lacked sensitivity for use in the diagnosis of chronic sinonasal disease. Conclusions: We have developed a sensitive, specific, and reproducible instrument to screen for chronic sinonasal disease. Validation studies of this five-item questionnaire are needed, including in patients with asthma. PMID:19581356

  10. Improving Detection of HIV-Associated Cognitive Impairment: Comparison of the International HIV Dementia Scale and a Brief Screening Battery.

    PubMed

    de Almeida, Sérgio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea E; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K; Ellis, Ronald J

    2017-03-01

    The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia, but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. A total of 108 participants (including 60 HIV-infected persons) completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible 3-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75%, respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared with the gold standard NP battery, were Trail Making Test A, Wechsler Adult Intelligence Scale III Digit Symbol and Hopkins Verbal Learning Test-Revised Total Recall (sensitivity 91%, specificity 96%), and Digit Symbol, Brief Visuospatial Memory Test-Revised Total Recall and Grooved Pegboard Test-dominant hand (sensitivity 94%, specificity 91%). Both test combinations can be administered in less than 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination.

  11. Detection of Methylated Circulating DNA as Noninvasive Biomarkers for Breast Cancer Diagnosis

    PubMed Central

    Cheuk, Isabella Wai Yin; Shin, Vivian Yvonne

    2017-01-01

    Internationally, breast cancer is the most common female cancer, and is induced by a combination of environmental, genetic, and epigenetic risk factors. Despite the advancement of imaging techniques, invasive sampling of breast epithelial cells is the only definitive diagnostic procedure for patients with breast cancer. To date, molecular biomarkers with high sensitivity and specificity for the screening and early detection of breast cancer are lacking. Recent evidence suggests that the detection of methylated circulating cell-free DNA in the peripheral blood of patients with cancer may be a promising quantitative and noninvasive method for cancer diagnosis. Methylation detection based on a multi-gene panel, rather than on the methylation status of a single gene, may be used to increase the sensitivity and specificity of breast cancer screening. In this review, the results of 14 relevant studies, investigating the efficacy of cell-free DNA methylation screening for breast cancer diagnosis, have been summarized. The genetic risk factors for breast cancer, the methods used for breast cancer detection, and the techniques and limitations related to the detection of cell-free DNA methylation status, have also been reviewed and discussed. From this review, we conclude that the analysis of peripheral blood or other samples to detect differentially methylated cell-free DNA is a promising technique for use in clinical settings, and may improve the sensitivity of screening for both, early detection and disease relapse, and thus improve the future prognosis of patients with breast cancer. PMID:28382090

  12. Urine benzodiazepines screening of involuntarily drugged and robbed or raped patients.

    PubMed

    Boussairi, A; Dupeyron, J P; Hernandez, B; Delaitre, D; Beugnet, L; Espinoza, P; Diamant-Berger, O

    1996-01-01

    This study involved 35 patients who claimed to have been drugged before being robbed or raped, despite urine negative toxicologic screening by immunoenzymatic methods. The urines were frozen for further investigations, including enzymatic hydrolysis of urinary conjugates, liquid-solid extraction and, finally, immunoenzymatic screening of concentrated urine extract. Urine benzodiazepines were analyzed by immunoenzymatic assay before and after enzymatic hydrolysis combined with extraction. On direct immunoenzymatic screening, 17 of the 35 urine samples were benzodiazepine positive. Enrichment of preserved specimens improved the detection threshold from 200 ng/mL to 50 ng/mL and 10 of the 18 negative urines became positive. This method allowed us to demonstrate the benzodiazepines in half of previously negative urine samples. Benzodiazepine screening is particularly problematic because of low dosage, rapid elimination, failure to detect conjugated metabolites by immunoenzymatic reagents and high threshold of sensitivity for certain substances.

  13. Fecal Immunochemical Test (FIT) for Colon Cancer Screening: Variable Performance with Ambient Temperature

    PubMed Central

    Doubeni, Chyke A.; Jensen, Christopher D.; Fedewa, Stacey A.; Quinn, Virginia P.; Zauber, Ann G.; Schottinger, Joanne E.; Corley, Douglas A.; Levin, Theodore R.

    2017-01-01

    Introduction Fecal immunochemical tests (FITs) are widely used in colorectal cancer (CRC) screening, but hemoglobin degradation, due to exposure of the collected sample to high temperatures, could reduce test sensitivity. We examined the relation of ambient temperature exposure with FIT positivity rate and sensitivity. Methods This was a retrospective cohort study of patients 50 to 75 years in Kaiser Permanente Northern California’s CRC screening program, which began mailing FIT kits annually to screen-eligible members in 2007. Primary outcomes were FIT positivity rate and sensitivity to detect CRC. Predictors were month, season, and daily ambient temperatures of test result dates based on US National Oceanic and Atmospheric Administration data. Results Patients (n =472,542) completed 1,141,162 FITs. Weekly test positivity rate ranged from 2.6% to 8.0% (median, 4.4%) and varied significantly by month (June/July vs December/January rate ratio [RR] =0.79, 95% confidence interval [CI], 0.76 to 0.83) and season. FIT sensitivity was lower in June/July (74.5%; 95% CI, 72.5 to 76.6) than January/December (78.9%; 95% CI, 77.0 to 80.7). Conclusions FITs completed during high ambient temperatures had lower positivity rates and lower sensitivity. Changing kit design, specimen transportation practices, or avoiding periods of high ambient temperatures may help optimize FIT performance, but may also increase testing complexity and reduce patient adherence, requiring careful study. PMID:28076249

  14. Cervical Cancer Screening Program by Visual Inspection: Acceptability and Feasibility in Health Insurance Companies.

    PubMed

    Horo, Apollinaire G; Didi-Kouko Coulibaly, Judith; Koffi, Abdoul; Tchounga, Boris; Seni, Konan; Aka, Kacou Edèle; Kone, Mamourou

    2015-01-01

    Objective. To assess willingness to participate and diagnostic accuracy of visual inspection for early detection of cervical neoplasia among women in a health insurance company. Patients and Method. Cervical cancer screening was systematically proposed to 800 women after consecutive information and awareness sessions. The screening method was visual inspection with acetic acid (VIA) or Lugol's iodine (VILI). Results. Among the 800 identified women, 640 (82%) have accepted the screening, their mean age was 39 years, and 12.0% of them were involved in a polygamist couple. 28.2% of women had prior cervical screening. VIA has been detected positive in 5.9% of women versus 8.6% for VILI. The sensitivity was 72.9% and specificity was 95.2% for VIA versus 71.2% and 97.3% for VILI respectively. The histological examination highlighted a nonspecific chronic cervicitis in 4.6%, CIN1 lesions in 5.91%, and CIN2/3 in 1.2% of the cases. Conclusion. Cervical cancer screening by visual inspection showed appropriate diagnostic accuracy when used to detect early cervical lesions. It is a simple and easy to perform method that could be introduced progressively in the health insurance policy while waiting for a national screening program.

  15. Systematic screening and characterization of flavonoid glycosides in Carthamus tinctorius L. by liquid chromatography/UV diode-array detection/electrospray ionization tandem mass spectrometry.

    PubMed

    Jin, Yu; Xiao, Yuan-sheng; Zhang, Fei-fang; Xue, Xing-ya; Xu, Qing; Liang, Xin-miao

    2008-02-13

    The traditional Chinese medicine (TCM) is a complex system, which always consists of numerous compounds with significant difference in the content and physical and chemical properties. In this paper, a screening method based on target molecular weights was developed to characterize the flavonoid glycosides in the flower of Carthamus tinctorius L. The screening tables of aglycone and glycan were designed, respectively, in order to select and combine freely. The multiple reaction monitoring (MRM) scan mode with higher sensitivity and selectivity was adopted in the screening, which benefit the characterization for the minor components. Seventy-seven flavonoid glycosides were screened out finally, and their structures were characterized by tandem mass spectrometric method in both positive and negative ion modes. The glycosylation mode, aglycone, sequence and/or the interglycosidic linkages of the glycan portion and glycosylation position were elucidated by the fragmentation rule in the MS. Numerous compounds screened out with this method showed the structure variety in secondary plant metabolites, and the purposeful screening systemically and subsequent structure characterization offered more information about the chemical constitutions of TCM.

  16. Time-lapse imaging assay using the BioStation CT: A sensitive drug-screening method for three-dimensional cell culture

    PubMed Central

    Sakamoto, Ruriko; Rahman, M Mamunur; Shimomura, Manami; Itoh, Manabu; Nakatsura, Tetsuya

    2015-01-01

    Three-dimensional (3D) cell culture is beneficial for physiological studies of tumor cells, due to its potential to deliver a high quantity of cell culture information that is representative of the cancer microenvironment and predictive of drug responses in vivo. Currently, gel-associated or matrix-associated 3D cell culture is comprised of intricate procedures that often result in experimental complexity. Therefore, we developed an innovative anti-cancer drug sensitivity screening technique for 3D cell culture on NanoCulture Plates (NCP) by employing the imaging device BioStation CT. Here, we showed that the human breast cancer cell lines BT474 and T47D form multicellular spheroids on NCP plates and compared their sensitivity to the anti-cancer drugs trastuzumab and paclitaxel using the BioStation CT. The anticancer drugs reduced spheroid migration velocity and suppressed spheroid fusion. In addition, primary cells derived from the human breast cancer tissues B58 and B61 grown on NCP plates also exhibited similar drug sensitivity. These results were in good agreement with the conventional assay method using ATP quantification. We confirmed the antitumor effects of the drugs on cells seeded in 96-well plates using the BioStation CT imaging technique. We expect this method to be useful in research for new antitumor agents and for drug sensitivity tests in individually-tailored cancer treatments. PMID:25865675

  17. Results of the two incidence screenings in the National Lung Screening Trial.

    PubMed

    Aberle, Denise R; DeMello, Sarah; Berg, Christine D; Black, William C; Brewer, Brenda; Church, Timothy R; Clingan, Kathy L; Duan, Fenghai; Fagerstrom, Richard M; Gareen, Ilana F; Gatsonis, Constantine A; Gierada, David S; Jain, Amanda; Jones, Gordon C; Mahon, Irene; Marcus, Pamela M; Rathmell, Joshua M; Sicks, JoRean

    2013-09-05

    The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).

  18. Faecal immunochemical tests versus guaiac faecal occult blood tests: what clinicians and colorectal cancer screening programme organisers need to know.

    PubMed

    Tinmouth, Jill; Lansdorp-Vogelaar, Iris; Allison, James E

    2015-08-01

    Although colorectal cancer (CRC) is a common cause of cancer-related death, it is fortunately amenable to screening with faecal tests for occult blood and endoscopic tests. Despite the evidence for the efficacy of guaiac-based faecal occult blood tests (gFOBT), they have not been popular with primary care providers in many jurisdictions, in part because of poor sensitivity for advanced colorectal neoplasms (advanced adenomas and CRC). In order to address this issue, high sensitivity gFOBT have been recommended, however, these tests are limited by a reduction in specificity compared with the traditional gFOBT. Where colonoscopy is available, some providers have opted to recommend screening colonoscopy to their patients instead of faecal testing, as they believe it to be a better test. Newer methods for detecting occult human blood in faeces have been developed. These tests, called faecal immunochemical tests (FIT), are immunoassays specific for human haemoglobin. FIT hold considerable promise over the traditional guaiac methods including improved analytical and clinical sensitivity for CRC, better detection of advanced adenomas, and greater screenee participation. In addition, the quantitative FIT are more flexible than gFOBT as a numerical result is reported, allowing customisation of the positivity threshold. When compared with endoscopy, FIT are less sensitive for the detection of advanced colorectal neoplasms when only one time testing is applied to a screening population; however, this is offset by improved participation in a programme of annual or biennial screens and a better safety profile. This review will describe how gFOBT and FIT work and will present the evidence that supports the use of FIT over gFOBT, including the cost-effectiveness of FIT relative to gFOBT. Finally, specific issues related to FIT implementation will be discussed, particularly with respect to organised CRC screening programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belinsky, Steven A; Palmisano, William A

    A molecular marker-based method for monitoring and detecting cancer in humans. Aberrant methylation of gene promoters is a marker for cancer risk in humans. A two-stage, or "nested" polymerase chain reaction method is disclosed for detecting methylated DNA sequences at sufficiently high levels of sensitivity to permit cancer screening in biological fluid samples, such as sputum, obtained non-invasively. The method is for detecting the aberrant methylation of the p16 gene, O 6-methylguanine-DNA methyltransferase gene, Death-associated protein kinase gene, RAS-associated family 1 gene, or other gene promoters. The method offers a potentially powerful approach to population-based screening for the detection ofmore » lung and other cancers.« less

  20. Rapid bacteriological screening of cosmetic raw materials by using bioluminescence.

    PubMed

    Nielsen, P; Van Dellen, E

    1989-01-01

    Incoming cosmetic raw materials are routinely tested for microbial content. Standard plate count methods require up to 72 h. A rapid, sensitive, and inexpensive raw material screening method was developed that detects the presence of bacteria by means of ATP (bioluminescence). With a 24-h broth enrichment, the minimum bacterial ATP detection threshold of 1 cfu/g sample can be achieved using purified firefly luciferin-luciferase and an ATP releasing reagent. By using this rapid screen, microbiologically free material may be released for production within 24 h, while contaminated material undergoes further quantitative and identification testing. In order for a raw material to be validated for this method it must be evaluated for (1) a potential nonmicrobial light-contributing reaction resulting in a false positive or, (2) degradation of the ATP giving a false negative, and (3) confirmation that the raw material has not overwhelmed the buffering capacity of the enrichment broth. The key criteria for a rapid screen was the sensitivity to detect less than one colony forming unit per g product, the speed to do this within 24 h, and cost efficiency. Bioluminescence meets these criteria. With an enrichment step, it can detect less than one cfu/g sample. After the enrichment step, analysis time per sample is approximately 2 min and the cost for material and reagents is less than one dollar per sample.

  1. Tear fluid proteomics multimarkers for diabetic retinopathy screening

    PubMed Central

    2013-01-01

    Background The aim of the project was to develop a novel method for diabetic retinopathy screening based on the examination of tear fluid biomarker changes. In order to evaluate the usability of protein biomarkers for pre-screening purposes several different approaches were used, including machine learning algorithms. Methods All persons involved in the study had diabetes. Diabetic retinopathy (DR) was diagnosed by capturing 7-field fundus images, evaluated by two independent ophthalmologists. 165 eyes were examined (from 119 patients), 55 were diagnosed healthy and 110 images showed signs of DR. Tear samples were taken from all eyes and state-of-the-art nano-HPLC coupled ESI-MS/MS mass spectrometry protein identification was performed on all samples. Applicability of protein biomarkers was evaluated by six different optimally parameterized machine learning algorithms: Support Vector Machine, Recursive Partitioning, Random Forest, Naive Bayes, Logistic Regression, K-Nearest Neighbor. Results Out of the six investigated machine learning algorithms the result of Recursive Partitioning proved to be the most accurate. The performance of the system realizing the above algorithm reached 74% sensitivity and 48% specificity. Conclusions Protein biomarkers selected and classified with machine learning algorithms alone are at present not recommended for screening purposes because of low specificity and sensitivity values. This tool can be potentially used to improve the results of image processing methods as a complementary tool in automatic or semiautomatic systems. PMID:23919537

  2. Risk factor assessment to anticipate performance in the National Developmental Screening Test in children from a disadvantaged area.

    PubMed

    Montes, Alejandro; Pazos, Gustavo

    2016-02-01

    Identifying children at risk of failing the National Developmental Screening Test by combining prevalences of children suspected of having inapparent developmental disorders (IDDs) and associated risk factors (RFs) would allow to save resources. 1. To estimate the prevalence of children suspected of having IDDs. 2. To identify associated RFs. 3. To assess three methods developed based on observed RFs and propose a pre-screening procedure. The National Developmental Screening Test was administered to 60 randomly selected children aged between 2 and 4 years old from a socioeconomically disadvantaged area from Puerto Madryn. Twenty-four biological and socioenvironmental outcome measures were assessed in order to identify potential RFs using bivariate and multivariate analyses. The likelihood of failing the screening test was estimated as follows: 1. a multivariate logistic regression model was developed; 2. a relationship was established between the number of RFs present in each child and the percentage of children who failed the test; 3. these two methods were combined. The prevalence of children suspected of having IDDs was 55.0% (95% confidence interval: 42.4%-67.6%). Six RFs were initially identified using the bivariate approach. Three of them (maternal education, number of health checkups and Z scores for height-for-age, and maternal age) were included in the logistic regression model, which has a greater explanatory power. The third method included in the assessment showed greater sensitivity and specificity (85% and 79%, respectively). The estimated prevalence of children suspected of having IDDs was four times higher than the national standards. Seven RFs were identified. Combining the analysis of risk factor accumulation and a multivariate model provides a firm basis for developing a sensitive, specific and practical pre-screening procedure for socioeconomically disadvantaged areas. Sociedad Argentina de Pediatría.

  3. Development of a screening tool to predict malnutrition among children under two years old in Zambia

    PubMed Central

    Hasegawa, Junko; Ito, Yoichi M; Yamauchi, Taro

    2017-01-01

    ABSTRACT Background: Maternal and child undernutrition is an important issue, particularly in low- and middle-income countries. Children at high risk of malnutrition should be prioritized to receive necessary interventions to minimize such risk. Several risk factors have been proposed; however, until now, there has been no appropriate evaluation method to identify these children. In sub-Saharan Africa, children commonly receive regular check-ups from community health workers. A simple and easy nutrition assessment method is therefore needed for use by semi-professional health workers. Objectives: The aim of this study was to develop and test a practical screening tool for community use in predicting growth stunting in children under two years in rural Zambia. Methods: Field research was conducted from July to August 2014 in Southern Province, Zambia. Two hundred and sixty-four mother-child pairs participated in the study. Anthropometric measurements were performed on all children and mothers, and all mothers were interviewed. Risk factors for the screening test were estimated by using least absolute shrinkage and selection operator analysis. After re-evaluating all participants using the new screening tool, a receiver operating characteristic curve was drawn to set the cut-off value. Sensitivity and specificity were also calculated. Results: The screening tool included age, weight-for-age Z-score status, birth weight, feeding status, history of sibling death, multiple birth, and maternal education level. The total score ranged from 0 to 22, and the cut-off value was eight. Sensitivity and specificity were 0.963 and 0.697 respectively. Conclusions: A screening tool was developed to predict children at high risk of malnutrition living in Zambia. Further longitudinal studies are needed to confirm the test’s validity in detecting future stunting and to investigate the effectiveness of malnutrition treatment. PMID:28730929

  4. The New Technologies for Cervical Cancer Screening randomised controlled trial. An overview of results during the first phase of recruitment.

    PubMed

    Ronco, Guglielmo; Brezzi, Silvia; Carozzi, Francesca; Dalla Palma, Paolo; Giorgi-Rossi, Paolo; Minucci, Daria; Naldoni, Carlo; Segnan, Nereo; Zappa, Marco; Zorzi, Manuel; Cuzick, Jack

    2007-10-01

    To study the impact of different cervical cancer screening strategies including HPV testing. A randomised controlled trial with a conventional arm (conventional cytology) and an experimental arm following two phases (first HPV testing+conventional cytology, second HPV testing alone). In phase one, different protocols were applied to different age groups (25-34 and 35-60). Published data on test accuracy during the phase one of recruitment are summarised. 45,307 women were recruited in phase one (about 95,000 overall). In the age group 35-60, HPV testing (by Hybrid Capture 2) alone at 2 RLU cut-off increased sensitivity vs. conventional cytology (relative sensitivity 1.41; 95% CI: 0.98-1.02) with a small loss in Positive Predictive Value (PPV; relative PPV 0.75; 95% CI: 0.45-1.25). Adding liquid-based cytology as screening test and referring to colposcopy women positive to either only marginally increased sensitivity but strongly reduced PPV. In the age group 25-34, similar results (relative sensitivity vs. conventional cytology 1.58; 95% CI: 1.032.44; relative PPV 0.78; 95% CI: 0.72-1.16) were obtained, despite 14% of women were HPV positive, with a strategy based on HPV alone as screening test, triaging HPV positive women by cytology, directly referring those ASCUS+ to colposcopy and repeating both tests after 1 year in those with normal cytology. HPV testing, if used as screening test, should be applied alone, with cytology triage essential in younger women but preferable at all ages. Follow-up data will allow analysis of the safety of prolonging screening intervals and the relative persistence of lesions detected with different methods.

  5. Multi-component identification and target cell-based screening of potential bioactive compounds in toad venom by UPLC coupled with high-resolution LTQ-Orbitrap MS and high-sensitivity Qtrap MS.

    PubMed

    Ren, Wei; Han, Lingyu; Luo, Mengyi; Bian, Baolin; Guan, Ming; Yang, Hui; Han, Chao; Li, Na; Li, Tuo; Li, Shilei; Zhang, Yangyang; Zhao, Zhenwen; Zhao, Haiyu

    2018-04-28

    Traditional Chinese medicines (TCMs) are undoubtedly treasured natural resources for discovering effective medicines in treating and preventing various diseases. However, it is still extremely difficult for screening the bioactive compounds due to the tremendous constituents in TCMs. In this work, the chemical composition of toad venom was comprehensively analyzed using ultra-high performance liquid chromatography (UPLC) coupled with high-resolution LTQ-Orbitrap mass spectrometry and 93 compounds were detected. Among them, 17 constituents were confirmed by standard substances and 8 constituents were detected in toad venom for the first time. Further, a compound database of toad venom containing the fullest compounds was further constructed using UPLC coupled with high-sensitivity Qtrap MS. Then a target cell-based approach for screening potential bioactive compounds from toad venom was developed by analyzing the target cell extracts. The reliability of this method was validated by negative controls and positive controls. In total, 17 components in toad venom were discovered to interact with the target cancer cells. Further, in vitro pharmacological trials were performed to confirm the anti-cancer activity of four of them. The results showed that the six bufogenins and seven bufotoxins detected in our research represented a promising resource to explore bufogenins/bufotoxins-based anticancer agents with low cardiotoxic effect. The target cell-based screening method coupled with the compound database of toad venom constructed by UPLC-Qtrap-MS with high sensitivity provide us a new strategy to rapidly screen and identify the potential bioactive constituents with low content in natural products, which was beneficial for drug discovery from other TCMs. ᅟ Graphical abstract.

  6. Detection of Cryptosporidium oocysts in fresh and frozen cattle faeces: comparison of three methods.

    PubMed

    Brook, E J; Christley, R M; French, N P; Hart, C A

    2008-01-01

    The aim of this study was to compare the performance of three commonly used screening tests for Cryptosporidium oocysts in fresh and frozen cattle faeces. Twenty-nine freshly voided faecal samples were collected from calves from three farms in the northwest of England. Three diagnostic tests for Cryptosporidium were carried out on each sample both before and after freezing - the modified Ziehl-Neelsen (MZN) and auramine phenol (APh) stains and a commercial enzyme immunoassay (EIA) kit, the ProSpecT Cryptosporidium Microplate assay (Remel, Lenexa, KS). Twelve samples were deemed positive by the reference standard (polymerase chain reaction, PCR). There were some discrepancies between the results of the screening tests and the levels of agreement were quantified. The sensitivity and specificity of each method was determined, with PCR as the gold standard. Sensitivity and specificity of the MZN stain was optimized when samples with fewer than two oocyst-like bodies were classified as negative. All three screening methods used were effective in detecting Cryptosporidium infection in both fresh and frozen calf faeces. This study has highlighted the value of determining characteristics of tests used for diagnosis and epidemiological studies.

  7. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2001-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen is disclosed. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. The prescreen is preferably formed by a collection of light transmitting and refracting elements, preferably spheres 80, partially embedded in a light blocking layer. Toward the back of the spheres 80 are effective apertures 82 where the light blocking layer 81 is absent or at least thinner than in other regions toward the side of the spheres. The projected image enters spheres 80 through the effective apertures 82, and exits the spheres 80 centered orientationally about the normal to the lens axis. The re-oriented light rays then enter the diffusion screen for viewing.

  8. Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens.

    PubMed

    Bohaychuk, Valerie M; Gensler, Gary E; King, Robin K; Wu, John T; McMullen, Lynn M

    2005-12-01

    Rapid and molecular technologies such as enzyme-linked immunosorbent assay (ELISA), PCR, and lateral flow immunoprecipitation can reduce the time and labor involved in screening food products for the presence of pathogens. These technologies were compared with conventional culture methodology for the detection of Salmonella, Campylobacter, Listeria, and Escherichia coli O157:H7 inoculated in raw and processed meat and poultry products. Recommended protocols were modified so that the same enrichment broths used in the culture methods were also used in the ELISA, PCR, and lateral flow immunoprecipitation assays. The percent agreement between the rapid technologies and culture methods ranged from 80 to 100% depending on the pathogen detected and the method used. ELISA, PCR, and lateral flow immunoprecipitation all performed well, with no statistical difference, compared with the culture method for the detection of E. coli O157:H7. ELISA performed better for the detection of Salmonella, with sensitivity and specificity rates of 100%. PCR performed better for the detection of Campylobacter jejuni, with 100% agreement to the culture method. PCR was highly sensitive for the detection of all the foodborne pathogens tested except Listeria monocytogenes. Although the lateral flow immunoprecipitation tests were statistically different from the culture methods for Salmonella and Listeria because of false-positive results, the tests did not produce any false negatives, indicating that this method would be suitable for screening meat and poultry products for these pathogens.

  9. Cost-effectiveness of breast cancer screening using mammography in Vietnamese women

    PubMed Central

    2018-01-01

    Background The incidence rate of breast cancer is increasing and has become the most common cancer in Vietnamese women while the survival rate is lower than that of developed countries. Early detection to improve breast cancer survival as well as reducing risk factors remains the cornerstone of breast cancer control according to the World Health Organization (WHO). This study aims to evaluate the costs and outcomes of introducing a mammography screening program for Vietnamese women aged 45–64 years, compared to the current situation of no screening. Methods Decision analytical modeling using Markov chain analysis was used to estimate costs and health outcomes over a lifetime horizon. Model inputs were derived from published literature and the results were reported as incremental cost-effectiveness ratios (ICERs) and/or incremental net monetary benefits (INMBs). One-way sensitivity analyses and probabilistic sensitivity analyses were performed to assess parameter uncertainty. Results The ICER per life year gained of the first round of mammography screening was US$3647.06 and US$4405.44 for women aged 50–54 years and 55–59 years, respectively. In probabilistic sensitivity analyses, mammography screening in the 50–54 age group and the 55–59 age group were cost-effective in 100% of cases at a threshold of three times the Vietnamese Gross Domestic Product (GDP) i.e., US$6332.70. However, less than 50% of the cases in the 60–64 age group and 0% of the cases in the 45–49 age group were cost effective at the WHO threshold. The ICERs were sensitive to the discount rate, mammography sensitivity, and transition probability from remission to distant recurrence in stage II for all age groups. Conclusion From the healthcare payer viewpoint, offering the first round of mammography screening to Vietnamese women aged 50–59 years should be considered, with the given threshold of three times the Vietnamese GDP per capita. PMID:29579131

  10. Cervical Cancer Screening in Low-Resource Settings: A Cost-Effectiveness Framework for Valuing Tradeoffs between Test Performance and Program Coverage

    PubMed Central

    Campos, Nicole G.; Castle, Philip E.; Wright, Thomas C.; Kim, Jane J.

    2016-01-01

    As cervical cancer screening programs are implemented in low-resource settings, protocols are needed to maximize health benefits under operational constraints. Our objective was to develop a framework for examining health and economic tradeoffs between screening test sensitivity, population coverage, and follow-up of screen-positive women, to help decision makers identify where program investments yield the greatest value. As an illustrative example, we used an individual-based Monte Carlo simulation model of the natural history of human papillomavirus (HPV) and cervical cancer calibrated to epidemiologic data from Uganda. We assumed once in a lifetime screening at age 35 with two-visit HPV DNA testing or one-visit visual inspection with acetic acid (VIA). We assessed the health and economic tradeoffs that arise between 1) test sensitivity and screening coverage; 2) test sensitivity and loss to follow-up (LTFU) of screen-positive women; and 3) test sensitivity, screening coverage, and LTFU simultaneously. The decline in health benefits associated with sacrificing HPV DNA test sensitivity by 20% (e.g., shifting from provider- to self-collection of specimens) could be offset by gains in coverage if coverage increased by at least 20%. When LTFU was 10%, two-visit HPV DNA testing with 80-90% sensitivity was more effective and more cost-effective than one-visit VIA with 40% sensitivity, and yielded greater health benefits than VIA even as VIA sensitivity increased to 60% and HPV test sensitivity declined to 70%. As LTFU increased, two-visit HPV DNA testing became more costly and less effective than one-visit VIA. Setting-specific data on achievable test sensitivity, coverage, follow-up rates, and programmatic costs are needed to guide programmatic decision making for cervical cancer screening. PMID:25943074

  11. Colon Capsule Endoscopy compared to Conventional Colonoscopy under routine screening conditions

    PubMed Central

    2010-01-01

    Background Colonoscopy (CSPY) for colorectal cancer screening has several limitations. Colon Capsule Endoscopy (PillCam Colon, CCE) was compared to CSPY under routine screening conditions. Methods We performed a prospective, single-center pilot study at a University Hospital. Data were obtained from November 2007 until May 2008. Patients underwent CCE on Day 1 and CSPY on Day 2. Outcomes were evaluated regarding sensitivity and specificity of polyp detection rate, with a significance level set at >5 mm. Results 59 individuals were included in this study, the results were evaluable in 56 patients (males 34, females 22; median age 59). CCE was complete in 36 subjects. Polyp detection rate for significant polyps was 11% on CSPY and 27% on CCE. 6/56 (11%) patients had polyps on CSPY not detected on CCE (miss rate). Overall sensitivity was 79% (95% confidence interval [CI], 61 to 90), specificity was 54% (95% CI, 35 to 70), positive predictive value (PPV) was 63% and negative predictive value (NPV) was 71%. Adjusted to significance of findings, sensitivity was 50% (95% CI, 19 to 81), specificity was 76% (95% CI, 63 to 86), PPV was 20% and NPV was 93%. Conclusion In comparison to the gold standard, the sensitivity of CCE for detection of relevant polyps is low, however, the high NPV supports its role as a possible screening tool. Trial Registration NCT00991003. PMID:20565828

  12. Introduction of a hydrolysis probe PCR assay for high-throughput screening of methicillin-resistant Staphylococcus aureus with the ability to include or exclude detection of Staphylococcus argenteus.

    PubMed

    Bogestam, Katja; Vondracek, Martin; Karlsson, Mattias; Fang, Hong; Giske, Christian G

    2018-01-01

    Many countries using sensitive screening methods for detection of carriage of methicillin-resistant Staphylococcus aureus (MRSA) have a sustained low incidence of MRSA infections. For diagnostic laboratories with high sample volumes, MRSA screening requires stability, low maintenance and high performance at a low cost. Herein we designed oligonucleotides for a new nuc targeted hydrolysis probe PCR to replace the standard in-house nuc SybrGreen PCR assay. This new, more time-efficient, PCR assay resulted in a 40% increase in daily sample capacity, with maintained high specificity and sensitivity. The assay was also able to detect Staphylococcus aureus clonal cluster 75 (CC75) lineage strains, recently re-classified as Staphylococcus argenteus, with a sensitivity considerably increased compared to our previous assay. While awaiting consensus if the CC75 lineage of S. aureus should be considered as S. argenteus, and whether methicillin-resistant S. argenteus should be included in the MRSA definition, many diagnostic laboratories need to update their MRSA assay sensitivity/specificity towards this lineage/species. The MRSA screening assay presented in this manuscript is comprised of nuc oligonucleotides separately targeting S. aureus and CC75 lineage strains/S. argenteus, thus providing high user flexibility for the detection of CC75 lineage strains/S. argenteus.

  13. Nested methylation-specific polymerase chain reaction cancer detection method

    DOEpatents

    Belinsky, Steven A [Albuquerque, NM; Palmisano, William A [Edgewood, NM

    2007-05-08

    A molecular marker-based method for monitoring and detecting cancer in humans. Aberrant methylation of gene promoters is a marker for cancer risk in humans. A two-stage, or "nested" polymerase chain reaction method is disclosed for detecting methylated DNA sequences at sufficiently high levels of sensitivity to permit cancer screening in biological fluid samples, such as sputum, obtained non-invasively. The method is for detecting the aberrant methylation of the p16 gene, O 6-methylguanine-DNA methyltransferase gene, Death-associated protein kinase gene, RAS-associated family 1 gene, or other gene promoters. The method offers a potentially powerful approach to population-based screening for the detection of lung and other cancers.

  14. Hierarchical screening for multiple mental disorders.

    PubMed

    Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J

    2013-10-01

    There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.

  15. Study designs for determining and comparing sensitivities of disease screening tests.

    PubMed

    Prorok, Philip C; Kramer, Barnett S; Miller, Anthony B

    2015-12-01

    To investigate the capability of various study designs to determine the sensitivity of a disease screening test. Quantities that can be calculated from these designs were derived and examined for their relationship to true sensitivity (the ability to detect unrecognized disease that would surface clinically in the absence of screening) and overdiagnosis. To examine the sensitivity of one test, the single cohort design, in which all participants receive the test, is particularly weak, providing only an upper bound on the true sensitivity, and yields no information about overdiagnosis. A randomized design, with one control arm and participants tested in the other, that includes sufficient post-screening follow-up, allows calculation of bounds on, and an approximation to, true sensitivity and also determination of overdiagnosis. Without follow-up, bounds on the true sensitivity can be calculated. To compare two tests, the single cohort paired design in which all participants receive both tests is precarious. The three arm randomized design with post screening follow-up is preferred, yielding an approximation to the true sensitivity, bounds on the true sensitivity, and the extent of overdiagnosis of each test. Without post screening follow-up, bounds on the true sensitivities can be calculated. When an unscreened control arm is not possible, the two-arm randomized design is recommended. Individual test sensitivities cannot be determined, but with sufficient post-screening follow-up, an order relationship can be established, as can the difference in overdiagnosis between the two tests. © The Author(s) 2015.

  16. Screen-Printing of ZnO Nanostructures from Sol-Gel Solutions for Their Application in Dye-Sensitized Solar Cells.

    PubMed

    Sarkar, Kuhu; Braden, Erik V; Bonke, Shannon A; Bach, Udo; Müller-Buschbaum, Peter

    2015-08-24

    Diblock copolymers have been used in sol-gel synthesis to successfully tailor the nanoscale morphology of thin ZnO films. As the fabrication of several-micron-thick mesoporous films such as those required in dye-sensitized solar cells (DSSCs) was difficult with this approach, we exploited the benefits of diblock-copolymer-directed synthesis that made it compatible with screen printing. The simple conversion of the diblock copolymer ZnO precursor sol to a screen-printing paste was not possible as it resulted in poor film properties. To overcome this problem, an alternative route is proposed in which the diblock copolymer ZnO precursor sol is first blade coated and calcined, then converted to a screen-printing paste. This allows the benefits of diblock-copolymer-directed particle formation to be compatible with printing methods. The morphologies of the ZnO nanostructures were studied by SEM and correlated with the current density-voltage characteristics. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment

    PubMed Central

    Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-01-01

    Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624

  18. A laboratory and field evaluation of a portable immunoassay test for triazine herbicides in environmental water samples

    USGS Publications Warehouse

    Schulze, P.A.; Capel, P.D.; Squillace, P.J.; Helsel, D.R.

    1993-01-01

    The usefulness and sensitivity, of a portable immunoassay test for the semiquantitative field screening of water samples was evaluated by means of laboratory and field studies. Laboratory results indicated that the tests were useful for the determination of atrazine concentrations of 0.1 to 1.5 μg/L. At a concentration of 1 μg/L, the relative standard deviation in the difference between the regression line and the actual result was about 40 percent. The immunoassay was less sensitive and produced similar errors for other triazine herbicides. After standardization, the test results were relatively insensitive to ionic content and variations in pH (range, 4 to 10), mildly sensitive to temperature changes, and quite sensitive to the timing of the final incubation step, variances in timing can be a significant source of error. Almost all of the immunoassays predicted a higher atrazine concentration in water samples when compared to results of gas chromatography. If these tests are used as a semiquantitative screening tool, this tendency for overprediction does not diminish the tests' usefulness. Generally, the tests seem to be a valuable method for screening water samples for triazine herbicides.

  19. MNSs Blood Group Glycophorin Variants in Taiwan: A Genotype-Serotype Correlation Study of ‘Mia’ and Sta with Report of Two New Alleles for Sta

    PubMed Central

    Chen, Tai-Di; Chen, Ding-Ping; Wang, Wei-Ting; Sun, Chien-Feng

    2014-01-01

    Background Glycophorin variants of the MNSs blood group are important in Taiwan. For more than 20 years, screening for the most frequent irregular antibody, anti-‘Mia’, has been conducted by using ‘Mia’(+) RBCs, with a significant success. However, the sensitivity and the specificity of this screening strategy have never been validated, and the true incidences of different glycophorin variants in Taiwan have been in controversy. Also, the significance of another less frequent and usually separately reported variant, Sta, has never been evaluated. Methodology/Principal Findings We ran a population-based screening (from unselected patients in our hospital) for MNSs blood group glycophorin variants by PCR-sequencing method. GP.Mur (Mil.III) was confirmed by sequence from 57 out of 1027 samples (5.6%), and there was no other Miltenberger subtype glycophorin variant found. Glycophorin variant Sta was found from 35 out of 1027 samples (3.4%). In contrast to anti-‘Mia’, which is the most frequently identified irregular antibody in Taiwan, the prevalence of anti-Sta was only 0.13% as determined by serologic method. In addition, two new alleles for Sta were found and reported. Conclusion/Significance We confirm the long-standing assumption that GP.Mur is the only prevalent Miltenberger subtype in Taiwan. The current anti-‘Mia’ screening method used in Taiwan, although neither sensitive nor specific, is still a suitable practice. Although Sta antigen has a high prevalence in Taiwan, routine screening for anti-Sta is not warranted based on current evidence. PMID:24858913

  20. Rapid and sensitive screening and selective quantification of antibiotics in human urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    PubMed

    Wang, He-Xing; Wang, Bin; Zhou, Ying; Jiang, Qing-Wu

    2014-12-01

    A rapid and sensitive method for the screening and selective quantification of antibiotics in urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry was developed. This method allowed the injection of 200 μL urine extract. The 200-μL injection volume used in this method increased the absolute sensitivity for target antibiotics in solvent by an average 13.3 times, with a range from 8.4 to 28.5 times, compared with the 10-μL conventional injection volume. A 96-well solid phase extraction procedure was established to eliminate the contamination on the chromatographic column resulting from the large-volume injection and increase the throughput of sample preparation. Fourteen target antibiotics from six common categories (β-lactams, quinolones, tetracyclines, macrolides, sulfonamides, and chloramphenicols) were selected as model compounds, and a database containing an additional 74 antibiotics was compiled for posttarget screening. The limit of detection of the target antibiotics, defined as a signal-to-noise ratio of 3, ranged from 0.04 to 1.99 ng/mL. The mean interday recoveries ranged between 79.6 and 121.3 %, with a relative standard deviation from 2.9 to 18.3 % at three spiking levels of 20 ng/mL, 50 ng/mL, and 100 ng/mL. This method was successfully applied in 60 real urine samples from schoolchildren aged 8-11 years, and four target antibiotics (azithromycin, sulfadiazine, trimethoprim, and oxytetracycline) and two posttarget antibiotics (sulfadimidine and cefaclor) were found in the urine samples. This method can be used as a large-scale biomonitoring tool for exposure of the human population to antibiotics.

  1. The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.

    PubMed

    Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M

    2016-09-01

    One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  2. Methods for Initial Characterization of Campylobacter jejuni Bacteriophages.

    PubMed

    Sørensen, Martine Camilla Holst; Gencay, Yilmaz Emre; Brøndsted, Lone

    2017-01-01

    Here we describe an initial characterization of Campylobacter jejuni bacteriophages by host range analysis, genome size determination by pulsed-field gel electrophoresis, and receptor-type identification by screening mutants for phage sensitivity.

  3. An special epithelial staining agents: folic acid receptor-mediated diagnosis (FRD) effectively and conveniently screen patients with cervical cancer.

    PubMed

    Lu, Meng-Han; Hu, Ling-Yun; Du, Xin-Xin; Yang, Min; Zhang, Wei-Yi; Huang, Ke; Li, Li-An; Jiang, Shu-Fang; Li, Ya-Li

    2015-01-01

    High-quality screening with cytology has markedly reduced mortality from cervical cancer. However, it needs experienced pathologists to review and make the final decisions. We have developed folic acid receptor-mediated diagnosis (FRD) kits to effectively and conveniently screen patients with cervical cancer. We conduct present study aim to assess clinical significances of FRD in screening cervical cancer. A total of 169 patients were enrolled at Chinese People's liberation Army (PLA) general hospital. We compared diagnostic significances of FRD with thinprep cytology test (TCT). Meanwhile, colposcopy was also performed to confirm any lesion suspicious for cervical cancer. The sensitivity and specificity of FRD were 71.93% and 66.07% in diagnosis cervical cancer, respectively. Meanwhile, the positive predictive values (PPV), negative predictive values (NPV), Youden index were 51.90%, 82.22%, 0.38, respectively. On the other hand, the sensitivity and specificity of TCT in diagnosis cervical cancer were 73.68% and 61.61% respectively. PPV, NPV and Youden index for TCT were 49.41%, 82.14% and 0.35 respectively. Overall, FRD have high values of sensitivity, specificity and Youden index. However, this difference failed to statistical significance. FRD have comparable diagnostic significance with TCT. Therefore, FRD might serve as one effective method to screen cervical cancer. Especially for those patients living in remote regions of China, where cytology was unavailable.

  4. An special epithelial staining agents: folic acid receptor-mediated diagnosis (FRD) effectively and conveniently screen patients with cervical cancer

    PubMed Central

    Lu, Meng-Han; Hu, Ling-Yun; Du, Xin-Xin; Yang, Min; Zhang, Wei-Yi; Huang, Ke; Li, Li-An; Jiang, Shu-Fang; Li, Ya-Li

    2015-01-01

    High-quality screening with cytology has markedly reduced mortality from cervical cancer. However, it needs experienced pathologists to review and make the final decisions. We have developed folic acid receptor-mediated diagnosis (FRD) kits to effectively and conveniently screen patients with cervical cancer. We conduct present study aim to assess clinical significances of FRD in screening cervical cancer. A total of 169 patients were enrolled at Chinese People’s liberation Army (PLA) general hospital. We compared diagnostic significances of FRD with thinprep cytology test (TCT). Meanwhile, colposcopy was also performed to confirm any lesion suspicious for cervical cancer. The sensitivity and specificity of FRD were 71.93% and 66.07% in diagnosis cervical cancer, respectively. Meanwhile, the positive predictive values (PPV), negative predictive values (NPV), Youden index were 51.90%, 82.22%, 0.38, respectively. On the other hand, the sensitivity and specificity of TCT in diagnosis cervical cancer were 73.68% and 61.61% respectively. PPV, NPV and Youden index for TCT were 49.41%, 82.14% and 0.35 respectively. Overall, FRD have high values of sensitivity, specificity and Youden index. However, this difference failed to statistical significance. FRD have comparable diagnostic significance with TCT. Therefore, FRD might serve as one effective method to screen cervical cancer. Especially for those patients living in remote regions of China, where cytology was unavailable. PMID:26221336

  5. Accuracy of visual inspection performed by community health workers in cervical cancer screening.

    PubMed

    Driscoll, Susan D; Tappen, Ruth M; Newman, David; Voege-Harvey, Kathi

    2018-05-22

    Cervical cancer remains the leading cause of cancer and mortality in low-resource areas with healthcare personnel shortages. Visual inspection is a low-resource alternative method of cervical cancer screening in areas with limited access to healthcare. To assess accuracy of visual inspection performed by community health workers (CHWs) and licensed providers, and the effect of provider training on visual inspection accuracy. Five databases and four websites were queried for studies published in English up to December 31, 2015. Derivations of "cervical cancer screening" and "visual inspection" were search terms. Visual inspection screening studies with provider definitions, colposcopy reference standards, and accuracy data were included. A priori variables were extracted by two independent reviewers. Bivariate linear mixed-effects models were used to compare visual inspection accuracy. Provider type was a significant predictor of visual inspection sensitivity (P=0.048); sensitivity was 15 percentage points higher among CHWs than physicians (P=0.014). Components of provider training were significant predictors of sensitivity and specificity. Community-based visual inspection programs using adequately trained CHWs could reduce barriers and expand access to screening, thereby decreasing cervical cancer incidence and mortality for women at highest risk and those living in remote areas with limited access to healthcare personnel. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Modulation of molecular hybridization and charge screening in a carbon nanotube network channel using the electrical pulse method.

    PubMed

    Woo, Jun-Myung; Kim, Seok Hyang; Chun, Honnggu; Kim, Sung Jae; Ahn, Jinhong; Park, Young June

    2013-09-21

    In this paper, we investigate the effect of electrical pulse bias on DNA hybridization events in a biosensor platform, using a Carbon Nanotube Network (CNN) and Gold Nano Particles (GNP) as an electrical channel. The scheme provides both hybridization rate enhancement of bio molecules, and electrical measurement in a transient state to avoid the charge screening effect, thereby significantly improving the sensitivity. As an example, the probe DNA molecules oscillate with pulse trains, resulting in the enhancement of DNA hybridization efficiency, and accordingly of the sensor performances in Tris-EDTA (TE) buffer solution, by as much as over three times, compared to the non-biasing conditions. More importantly, a wide dynamic range of 10(6) (target-DNA concentration from 5 pM to 5 μM) is achieved in human serum. In addition, the pulse biasing method enables one to obtain the conductance change, before the ions within the Electrical Double Layer (EDL) are redistributed, to avoid the charge screening effect, leading to an additional sensitivity enhancement.

  7. Evaluation of a specialized filter-paper matrix for transportation of extended bovine semen to screen for bovine herpesvirus-1 by real-time PCR.

    PubMed

    Sarangi, Laxmi Narayan; Naveena, Thodangala; Rana, Samir Kumar; Surendra, Kota Sri Naga Leela; Reddy, Rachamreddy Venkata Chandrasekhar; Bajibabu, Putla; Ponnanna, Nadikerianda Muthappa; Sharma, Girish Kumar; Srinivasan, Villuppanoor Alwar

    2018-07-01

    The extended frozen semen (EFS) batches produced from infectious bovine rhinotracheitis (IBR) sero-positive cattle and buffalo bulls housed in various semen stations in India are transported to the testing laboratory in liquid nitrogen (LN 2 ) for screening bovine herpesvirus-1 (BoHV-1). This procedure is laborious and poses LN 2 related hazards. An alternative logistics for transportation of samples was investigated. Use of Flinders Technology Associates (FTA ® ) elute card was evaluated for transportation of extended bovine semen to screen BoHV-1 DNA by real-time PCR targeting gB gene and the method was compared with the OIE approved Chelex resin based method. A protocol for extraction of BoHV-1 DNA from FTA ® card spotted with extended semen was optimized. The viral DNA was found to be stable on FTA ® card for at least 28 days when the cards are stored at 4°-37 °C. The analytical sensitivity for the assay was determined using variable dilutions of BoHV-1 spiked semen and positive plasmid harbouring gB gene (97bp) spotted onto FTA ® card and it was found to be 10 0.8 TCID 50 /ml or 100 copies respectively in real-time PCR. The test could detect as low as 10 0.008 TCID 50 /ml or 1 copy of positive plasmid when more number of replicates (n = 6) of the same sample were tested. This sensitivity was found to be comparable to Chelex method and both the methods demonstrated a very strong correlation (r = 0.9774; 95% CI: 0.9620-0.9860) in terms of Ct value (p < 0.0001). The diagnostic sensitivity and specificity of the FTA method in comparison to the Chelex method was 83.08% (95% CI: 71.73%-91.24%) and 93.23% (95% CI: 89.38%-96.01%) respectively when 316 samples were screened by both the methods. The degree of agreement between these two tests was good (Kappa value: 0.738; 95% CI: 0.646-0.829). The method was found to be robust and highly repeatable in inter-assay and intra-assay precision testing. The result suggests that the FTA ® card holds promise as an alternative system for transportation of EFS for downstream screening of BoHV-1 DNA. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Normal taste acuity and preference in female adolescents with impaired 6-n-propylthiouracil sensitivity.

    PubMed

    Nagai, Ayako; Kubota, Masaru; Sakai, Midori; Higashiyama, Yukie

    2014-01-01

    This study was conducted to determine the relationship between 6-n-propylthiouracil sensitivity and taste characteristics in female students at Nara Women's University. Participants (n=135) were screened for 6-npropylthiouracil sensitivity using a taste test with 0.56 mM 6-n-propylthiouracil solution, and the sensitivity was confirmed by an assay for the bitter-taste receptor gene, TAS2R38. Based on the screening results, 33 6-npropylthiouracil tasters and 21 non-tasters were enrolled. The basic characteristics that are thought to influence taste acuity, including body mass index, saliva volume and serum micronutrient concentrations (iron, zinc and copper), were similar between the two groups. In an analysis using a filter-paper disc method, there were no differences in the acuity for four basic tastes (sweet, salty, sour and bitter) between 6-n-propylthiouracil tasters and non-tasters. In addition, the taste preference for the four basic tastes as measured by a visual analogue scale was also comparable between the two groups. This is the first study to demonstrate that 6-n-propylthiouracil nontasters have taste sensitivity for the four basic tastes similar to that in 6-n-propylthiouracil tasters, at least in female adolescents, as measured by the gustatory test using a filter-paper disc method.

  9. Effectiveness of VIA, Pap, and HPV DNA Testing in a Cervical Cancer Screening Program in a Peri-Urban Community in Andhra Pradesh, India

    PubMed Central

    Gravitt, Patti E.; Paul, Proma; Katki, Hormuzd A.; Vendantham, Haripriya; Ramakrishna, Gayatri; Sudula, Mrudula; Kalpana, Basany; Ronnett, Brigitte M.; Vijayaraghavan, K.; Shah, Keerti V.

    2010-01-01

    Background While many studies have compared the efficacy of Pap cytology, visual inspection with acetic acid (VIA) and human papillomavirus (HPV) DNA assays for the detection cervical intraepithelial neoplasia and cancer, few have evaluated the program effectiveness. Methods and Findings A population-based sample of 5603 women from Medchal Mandal in Andhra Pradesh, India were invited to participate in a study comparing Pap cytology, VIA, and HPV DNA screening for the detection of CIN3+. Participation in primary screening and all subsequent follow-up visits was rigorously tracked. A 20% random sample of all women screened, in addition to all women with a positive screening test result underwent colposcopy with directed biopsy for final diagnosis. Sensitivity, specificity, positive and negative predictive values were adjusted for verification bias. HPV testing had a higher sensitivity (100%) and specificity (90.6%) compared to Pap cytology (sensitivity  =  78.2%; specificity = 86.0%) and VIA (sensitivity = 31.6%; specificity = 87.5%). Since 58% of the sample refused involvement and another 28% refused colposcopy or biopsy, we estimated that potentially 87.6% of the total underlying cases of CIN3 and cancer may have been missed due to program failures. Conclusions We conclude that despite our use of available resources, infrastructure, and guidelines for cervical cancer screening implementation in resource limited areas, community participation and non-compliance remain the major obstacles to successful reduction in cervical cancer mortality in this Indian population. HPV DNA testing was both more sensitive and specific than Pap cytology and VIA. The use of a less invasive and more user-friendly primary screening strategy (such as self-collected swabs for HPV DNA testing) may be required to achieve the coverage necessary for effective reduction in cervical cancer mortality. PMID:21060889

  10. A new concept and a comprehensive evaluation of SYSMEX UF-1000i  flow cytometer to identify culture-negative urine specimens in patients with UTI.

    PubMed

    Monsen, T; Ryden, P

    2017-09-01

    Urinary tract infections (UTIs) are among the most common bacterial infections in men and urine culture is gold standard for diagnosis. Considering the high prevalence of culture-negative specimens, any method that identifies such specimens is of interest. The aim was to evaluate a new screening concept for flow cytometry analysis (FCA). The outcomes were evaluated against urine culture, uropathogen species and three conventional screening methods. A prospective, consecutive study examined 1,312 urine specimens, collected during January and February 2012. The specimens were analyzed using the Sysmex UF1000i FCA. Based on the FCA data culture negative specimens were identified in a new model by use of linear discriminant analysis (FCA-LDA). In total 1,312 patients were included. In- and outpatients represented 19.6% and 79.4%, respectively; 68.3% of the specimens originated from women. Of the 610 culture-positive specimens, Escherichia coli represented 64%, enterococci 8% and Klebsiella spp. 7%. Screening with FCA-LDA at 95% sensitivity identified 42% (552/1312) as culture negative specimens when UTI was defined according to European guidelines. The proposed screening method was either superior or similar in comparison to the three conventional screening methods. In conclusion, the proposed/suggested and new FCA-LDA screening method was superior or similar to three conventional screening methods. We recommend the proposed screening method to be used in clinic to exclude culture negative specimens, to reduce workload, costs and the turnaround time. In addition, the FCA data may add information that enhance handling and support diagnosis of patients with suspected UTI pending urine culture [corrected].

  11. Assessing direct analysis in real-time-mass spectrometry (DART-MS) for the rapid identification of additives in food packaging.

    PubMed

    Ackerman, L K; Noonan, G O; Begley, T H

    2009-12-01

    The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.

  12. The in-capillary DPPH-capillary electrophoresis-the diode array detector combined with reversed-electrode polarity stacking mode for screening and quantifying major antioxidants in Cuscuta chinensis Lam.

    PubMed

    Liu, Jiao; Tian, Ji; Li, Jin; Azietaku, John Teye; Zhang, Bo-Li; Gao, Xiu-Mei; Chang, Yan-Xu

    2016-07-01

    An in-capillary 2, 2-diphenyl-1-picrylhydrazyl (DPPH)-CE-the DAD (in-capillary DPPH-CE-DAD) combined with reversed-electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β-CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p-coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH-CE-DAD method. Sensitivity was enhanced under reversed-electrode polarity stacking mode and 10- to 31-fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in-capillary DPPH-CE-DAD method combined with reversed-electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Development of a test of suprathreshold acuity in noise in Brazilian Portuguese: a new method for hearing screening and surveillance.

    PubMed

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: "a hearing check is recommended" (red light), "a hearing check would be advisable" (yellow light), and "no hearing difficulties" (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention.

  14. Smartphone-Based Hearing Screening in Noisy Environments

    PubMed Central

    Na, Youngmin; Joo, Hyo Sung; Yang, Hyejin; Kang, Soojin; Hong, Sung Hwa; Woo, Jihwan

    2014-01-01

    It is important and recommended to detect hearing loss as soon as possible. If it is found early, proper treatment may help improve hearing and reduce the negative consequences of hearing loss. In this study, we developed smartphone-based hearing screening methods that can ubiquitously test hearing. However, environmental noise generally results in the loss of ear sensitivity, which causes a hearing threshold shift (HTS). To overcome this limitation in the hearing screening location, we developed a correction algorithm to reduce the HTS effect. A built-in microphone and headphone were calibrated to provide the standard units of measure. The HTSs in the presence of either white or babble noise were systematically investigated to determine the mean HTS as a function of noise level. When the hearing screening application runs, the smartphone automatically measures the environmental noise and provides the HTS value to correct the hearing threshold. A comparison to pure tone audiometry shows that this hearing screening method in the presence of noise could closely estimate the hearing threshold. We expect that the proposed ubiquitous hearing test method could be used as a simple hearing screening tool and could alert the user if they suffer from hearing loss. PMID:24926692

  15. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia

    PubMed Central

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-01-01

    Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612

  16. A deep learning method for early screening of lung cancer

    NASA Astrophysics Data System (ADS)

    Zhang, Kunpeng; Jiang, Huiqin; Ma, Ling; Gao, Jianbo; Yang, Xiaopeng

    2018-04-01

    Lung cancer is the leading cause of cancer-related deaths among men. In this paper, we propose a pulmonary nodule detection method for early screening of lung cancer based on the improved AlexNet model. In order to maintain the same image quality as the existing B/S architecture PACS system, we convert the original CT image into JPEG format image by analyzing the DICOM file firstly. Secondly, in view of the large size and complex background of CT chest images, we design the convolution neural network on basis of AlexNet model and sparse convolution structure. At last we train our models on the software named DIGITS which is provided by NVIDIA. The main contribution of this paper is to apply the convolutional neural network for the early screening of lung cancer and improve the screening accuracy by combining the AlexNet model with the sparse convolution structure. We make a series of experiments on the chest CT images using the proposed method, of which the sensitivity and specificity indicates that the method presented in this paper can effectively improve the accuracy of early screening of lung cancer and it has certain clinical significance at the same time.

  17. Using Publicly Reported Nursing-Sensitive Screening Indicators to Measure Hospital Performance: The Netherlands Experience in 2011.

    PubMed

    Stalpers, Dewi; van der Linden, Dimitri; Kaljouw, Marian J; Schuurmans, Marieke J

    2016-01-01

    Deliberate screening allows detection of health risks that are otherwise not noticeable and allows expedient intervention to minimize complications and optimize outcomes, especially during critical events like hospitalization. Little research has evaluated the usefulness of screening performance and outcome indicators as measures to differentiate nursing quality, although policymakers are using them to benchmark hospitals. The aims of this study were to examine hospital performance based on nursing-sensitive screening indicators and to assess associations with hospital characteristics and nursing-sensitive outcomes for patients. A secondary use of nursing-sensitive data from the Dutch Health Care Inspectorate was performed, including the mandatory screening and outcome indicators related to delirium, malnutrition, pain and pressure ulcers. The sample consisted of all 93 hospitals in the Netherlands in 2011. High- and low-performing hospitals were determined based on the overall proportion of screened patients. Descriptive statistics and analysis of variance were used to examine screening performances in relation to hospital characteristics and nursing-sensitive outcomes. Over all hospitals, the average screening rates ranged from 59% (delirium) to 94% (pain). Organizational characteristics were not different in high- and low-performing hospitals. The hospitals with the best overall screening performances had significantly better results regarding protein intake within malnourished patients (p < .01). For mortality, marginal significant effects did not remain after controlling for organizational structures. No associations were found with prevalence of pressure ulcers and patient self-reported pain scores. The screening for patient risks is an important nursing task. Our findings suggest that nursing-sensitive screening indicators may be relevant measures for benchmarking nursing quality in hospitals. Time-trend studies are required to support our findings and to further investigate relations with nursing-sensitive outcomes.

  18. Identifying DNA Methylation Biomarkers for Non-Endoscopic Detection of Barrett’s Esophagus

    PubMed Central

    Moinova, Helen R.; LaFramboise, Thomas; Lutterbaugh, James D.; Chandar, Apoorva Krishna; Dumot, John; Faulx, Ashley; Brock, Wendy; De la Cruz Cabrera, Omar; Guda, Kishore; Barnholtz-Sloan, Jill S.; Iyer, Prasad G.; Canto, Marcia I.; Wang, Jean S.; Shaheen, Nicholas J.; Thota, Prashanti N.; Willis, Joseph E.; Chak, Amitabh; Markowitz, Sanford D.

    2018-01-01

    We report a biomarker-based non-endoscopic method for detecting Barrett’s esophagus (BE), based on detecting methylated DNAs retrieved via a swallowable balloon-based esophageal sampling device. BE is the precursor of, and a major recognized risk factor for, developing esophageal adenocarcinoma (EAC). Endoscopy, the current standard for BE detection, is not cost-effective for population screening. We performed genome-wide screening to ascertain regions targeted for recurrent aberrant cytosine methylation in BE, identifying high-frequency methylation within the CCNA1 locus. We tested CCNA1 DNA methylation as a BE biomarker in cytology brushings of the distal esophagus from 173 individuals with or without BE. CCNA1 DNA methylation demonstrated an area under the curve (AUC)=0.95 for discriminating BE-related metaplasia and neoplasia cases versus normal individuals, performing identically to methylation of VIM DNA, an established BE biomarker. When combined, the resulting two biomarker panel was 95% sensitive and 91% specific. These results were replicated in an independent validation cohort of 149 individuals, who were assayed using the same cutoff values for test positivity established in the training population. To progress toward non-endoscopic esophageal screening, we engineered a well-tolerated, swallowable, encapsulated balloon device able to selectively sample the distal esophagus within 5 minutes. In balloon samples from 86 individuals, tests of CCNA1 plus VIM DNA methylation detected BE metaplasia with 90.3% sensitivity and 91.7% specificity. Combining the balloon sampling device with molecular assays of CCNA1 plus VIM DNA methylation enables an efficient, well-tolerated, sensitive, and specific method of screening at-risk populations for BE. PMID:29343623

  19. Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China

    PubMed Central

    Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan

    2015-01-01

    Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582

  20. Development of a loop-mediated isothermal amplification method for rapid mass-screening of sand flies for Leishmania infection.

    PubMed

    Nzelu, Chukwunonso O; Gomez, Eduardo A; Cáceres, Abraham G; Sakurai, Tatsuya; Martini-Robles, Luiggi; Uezato, Hiroshi; Mimori, Tatsuyuki; Katakura, Ken; Hashiguchi, Yoshihisa; Kato, Hirotomo

    2014-04-01

    Entomological monitoring of Leishmania infection in leishmaniasis endemic areas offers epidemiologic advantages for predicting the risk and expansion of the disease, as well as evaluation of the effectiveness of control programs. In this study, we developed a highly sensitive loop-mediated isothermal amplification (LAMP) method for the mass screening of sand flies for Leishmania infection based on the 18S rRNA gene. The LAMP technique could detect 0.01 parasites, which was more sensitive than classical PCR. The method was robust and could amplify the target DNA within 1h from a crude sand fly template without DNA purification. Amplicon detection could be accomplished by the newly developed colorimetric malachite green (MG)--mediated naked eye visualization. Pre-addition of MG to the LAMP reaction solution did not inhibit amplification efficiency. The field applicability of the colorimetric MG-based LAMP assay was demonstrated with 397 field-caught samples from the endemic areas of Ecuador and eight positive sand flies were detected. The robustness, superior sensitivity, and ability to produce better visual discriminatory reaction products than existing LAMP fluorescence and turbidity assays indicated the field potential usefulness of this new method for surveillance and epidemiological studies of leishmaniasis in developing countries. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Reevaluation of confirmatory tests for human T-cell leukemia virus Type 1 using a luciferase immunoprecipitation system in blood donors.

    PubMed

    Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya

    2015-04-01

    Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.

  2. A New Versatile Microarray-based Method for High Throughput Screening of Carbohydrate-active Enzymes*

    PubMed Central

    Vidal-Melgosa, Silvia; Pedersen, Henriette L.; Schückel, Julia; Arnal, Grégory; Dumon, Claire; Amby, Daniel B.; Monrad, Rune Nygaard; Westereng, Bjørge; Willats, William G. T.

    2015-01-01

    Carbohydrate-active enzymes have multiple biological roles and industrial applications. Advances in genome and transcriptome sequencing together with associated bioinformatics tools have identified vast numbers of putative carbohydrate-degrading and -modifying enzymes including glycoside hydrolases and lytic polysaccharide monooxygenases. However, there is a paucity of methods for rapidly screening the activities of these enzymes. By combining the multiplexing capacity of carbohydrate microarrays with the specificity of molecular probes, we have developed a sensitive, high throughput, and versatile semiquantitative enzyme screening technique that requires low amounts of enzyme and substrate. The method can be used to assess the activities of single enzymes, enzyme mixtures, and crude culture broths against single substrates, substrate mixtures, and biomass samples. Moreover, we show that the technique can be used to analyze both endo-acting and exo-acting glycoside hydrolases, polysaccharide lyases, carbohydrate esterases, and lytic polysaccharide monooxygenases. We demonstrate the potential of the technique by identifying the substrate specificities of purified uncharacterized enzymes and by screening enzyme activities from fungal culture broths. PMID:25657012

  3. Determination of a steroid profile in heel prick blood using LC-MS/MS.

    PubMed

    Boelen, Anita; Ruiter, An F C; Claahsen-van der Grinten, Hedi L; Endert, Erik; Ackermans, Mariette T

    2016-01-01

    The aim of this study was to improve the sensitivity of the congenital adrenal hyperplasia (CAH) neonatal screening by including second-tier steroid profiling on a DBS using LC-MS. We developed a method to measure the steroid profile in DBS and established gestational age-specific reference ranges of cortisol, cortisone, 11-deoxycortisol, 21-deoxycortisol, 17-hydroxyprogesterone, testosterone, Δ4-androstenedione, corticosterone and 11-deoxycorticosterone using 450 heel prick samples of neonates, participating in the Dutch Screening Program. Analyzing 92 cards with a positive CAH screening showed that only 21-deoxycortisol was 100% specific for diagnosed CAH patients. Steroid precursors can be measured in DBS and we suggest to implement the method as a second tier testing for CAH in The Netherlands.

  4. A Screening Method for Assessing Cumulative Impacts

    PubMed Central

    Alexeeff, George V.; Faust, John B.; August, Laura Meehan; Milanes, Carmen; Randles, Karen; Zeise, Lauren; Denton, Joan

    2012-01-01

    The California Environmental Protection Agency (Cal/EPA) Environmental Justice Action Plan calls for guidelines for evaluating “cumulative impacts.” As a first step toward such guidelines, a screening methodology for assessing cumulative impacts in communities was developed. The method, presented here, is based on the working definition of cumulative impacts adopted by Cal/EPA [1]: “Cumulative impacts means exposures, public health or environmental effects from the combined emissions and discharges in a geographic area, including environmental pollution from all sources, whether single or multi-media, routinely, accidentally, or otherwise released. Impacts will take into account sensitive populations and socio-economic factors, where applicable and to the extent data are available.” The screening methodology is built on this definition as well as current scientific understanding of environmental pollution and its adverse impacts on health, including the influence of both intrinsic, biological factors and non-intrinsic socioeconomic factors in mediating the effects of pollutant exposures. It addresses disparities in the distribution of pollution and health outcomes. The methodology provides a science-based tool to screen places for relative cumulative impacts, incorporating both the pollution burden on a community- including exposures to pollutants, their public health and environmental effects- and community characteristics, specifically sensitivity and socioeconomic factors. The screening methodology provides relative rankings to distinguish more highly impacted communities from less impacted ones. It may also help identify which factors are the greatest contributors to a community’s cumulative impact. It is not designed to provide quantitative estimates of community-level health impacts. A pilot screening analysis is presented here to illustrate the application of this methodology. Once guidelines are adopted, the methodology can serve as a screening tool to help Cal/EPA programs prioritize their activities and target those communities with the greatest cumulative impacts. PMID:22470315

  5. Comparison of simple screening criteria with the International Caries Detection and Assessment System classification in determining restorative treatment need.

    PubMed

    Kämppi, Antti; Tanner, Tarja; Päkkilä, Jari; Patinen, Pertti; Tjäderhane, Leo; Anttonen, Vuokko

    2016-04-01

    The Finnish Defence Forces' unique oral health-screening protocol (FDFsp) has been in use for decades. In FDFsp, restorative treatment need is determined based on the World Health Organization (WHO) criteria. The aim of this study was to compare the outcome of screening restorative treatment need with the outcome of using the International Caries Detection and Assessment System (ICDAS) classification at both individual and tooth levels. Our hypothesis was that the outcome of screening with FDFsp agrees with the outcome of using the ICDAS classification. In this study, a trained, calibrated examiner estimated, in a visual-tactile manner the restorative treatment need of 337 young healthy adults using the FDFsp. During the screening, 74 conscripts were selected for a thorough inspection. The inclusion criteria for those selected were: having no, having one to five, or having six or more caries lesions needing restorative treatment. In the thorough inspection, the participants were inspected in a visual-tactile manner using the ICDAS classification. The association of the outcomes achieved using the two different methods was analysed at individual and tooth levels. Sensitivity, specificity, and kappa values were calculated. Wisdom teeth were excluded. At the individual level, the agreement between the outcomes of using FDFsp and ICDAS ≥4 was excellent: sensitivity, 94.1%; specificity, 97.5%; and kappa = 0.92. When ICDAS ≥3 was used, the values were 72.7%, 96.7%, and 0.66%, respectively. Screening performed by a trained examiner using specific criteria is a reliable method for detecting individuals with restorative treatment need. The outcome of screening agrees strongly with results using the ICDAS classification. © 2015 FDI World Dental Federation.

  6. Radiologists’ Interpretive Skills in Screening vs. Diagnostic Mammography: Are They Related?

    PubMed Central

    Elmore, Joann G.; Cook, Andrea J.; Bogart, Andy; Carney, Patricia A.; Geller, Berta; Taplin, Stephen; Buist, Diana SM; Onega, Tracy; Lee, Christoph I.; Miglioretti, Diana L.

    2016-01-01

    Purpose To determine whether radiologists who perform well in screening also perform well in interpreting diagnostic mammography. Materials & Methods We evaluated the accuracy of 468 radiologists interpreting 2,234,947 screening and 196,164 diagnostic mammograms. Adjusting for site, radiologist, and patient characteristics, we identified radiologists with performance in the highest tertile and compared to those with lower performance. Results A moderate correlation was noted for radiologists’ accuracy when interpreting screening versus their accuracy on diagnostic exams: sensitivity (rspearman=0.51, 95% CI: 0.22, 0.80; P=0.0006), specificity (rspearman=0.40, 95% CI: 0.30, 0.49; P<0.0001). Conclusion Different educational approaches to screening and diagnostic imaging should be considered. PMID:27438069

  7. [Use the Markov-decision tree model to optimize vaccination strategies of hepatitis E among women aged 15 to 49].

    PubMed

    Chen, Z M; Ji, S B; Shi, X L; Zhao, Y Y; Zhang, X F; Jin, H

    2017-02-10

    Objective: To evaluate the cost-utility of different hepatitis E vaccination strategies in women aged 15 to 49. Methods: The Markov-decision tree model was constructed to evaluate the cost-utility of three hepatitis E virus vaccination strategies. Parameters of the models were estimated on the basis of published studies and experience of experts. Both methods on sensitivity and threshold analysis were used to evaluate the uncertainties of the model. Results: Compared with non-vaccination group, strategy on post-screening vaccination with rate as 100%, could save 0.10 quality-adjusted life years per capital in the women from the societal perspectives. After implementation of screening program and with the vaccination rate reaching 100%, the incremental cost utility ratio (ICUR) of vaccination appeared as 5 651.89 and 6 385.33 Yuan/QALY, respectively. Vaccination post to the implementation of a screening program, the result showed better benefit than the vaccination rate of 100%. Results from the sensitivity analysis showed that both the cost of hepatitis E vaccine and the inoculation compliance rate presented significant effects. If the cost were lower than 191.56 Yuan (RMB) or the inoculation compliance rate lower than 0.23, the vaccination rate of 100% strategy was better than the post-screening vaccination strategy, otherwise the post-screening vaccination strategy appeared the optimal strategy. Conclusion: Post-screening vaccination for women aged 15 to 49 from social perspectives seemed the optimal one but it had to depend on the change of vaccine cost and the rate of inoculation compliance.

  8. Comparing sensitivity and specificity of screening mammography in the United States and Denmark

    PubMed Central

    Jacobsen, Katja Kemp; O'Meara, Ellen S.; Key, Dustin; Buist, Diana SM; Kerlikowske, Karla; Vejborg, Ilse; Sprague, Brian L.; Lynge, Elsebeth; von Euler-Chelpin, My

    2015-01-01

    Delivery of screening mammography differs substantially between the United States (US) and Denmark. We evaluate whether there are differences in screening sensitivity and specificity. We included screens from women screened at age 50-69 years during 1996-2008/2009 in the US Breast Cancer Surveillance Consortium (BCSC) (n=2,872,791), and from two population-based mammography screening programs in Denmark (Copenhagen, n=148,156 and Funen, n=275,553). Women were followed for one year. For initial screens, recall rate was significantly higher in BCSC (17.6%) than in Copenhagen (4.3%) and Funen (3.1%). Sensitivity was fairly similar in BCSC (91.8%) and Copenhagen (90.5%) and Funen (92.5%). At subsequent screens, recall rates were 8.8%, 1.8% and 1.4% in BCSC, Copenhagen and Funen, respectively. The BCSC sensitivity (82.3%) was lower compared to Copenhagen (88.9%) and Funen (86.9%), but when stratified by time since last screen, the sensitivity was similar. For both initial and subsequent screening, the specificity of screening in BCSC (83.2 and 91.6%) was significantly lower than in Copenhagen (96.6 and 98.8%) and Funen. (97.9 and 99.2%). Taking time since last screen into account, American and Danish women had the same probability of having their asymptomatic cancers detected at screening. However, the majority of women free of asymptomatic cancers experienced more harms in terms of false-positive findings in the US than in Denmark. PMID:25944711

  9. Analysis of the discriminative methods for diagnosis of benign and malignant solitary pulmonary nodules based on serum markers.

    PubMed

    Wang, Wanping; Liu, Mingyue; Wang, Jing; Tian, Rui; Dong, Junqiang; Liu, Qi; Zhao, Xianping; Wang, Yuanfang

    2014-01-01

    Screening indexes of tumor serum markers for benign and malignant solitary pulmonary nodules (SPNs) were analyzed to find the optimum method for diagnosis. Enzyme-linked immunosorbent assays, an automatic immune analyzer and radioimmunoassay methods were used to examine the levels of 8 serum markers in 164 SPN patients, and the sensitivity for differential diagnosis of malignant or benign SPN was compared for detection using a single plasma marker or a combination of markers. The results for serological indicators that closely relate to benign and malignant SPNs were screened using the Fisher discriminant analysis and a non-conditional logistic regression analysis method, respectively. The results were then verified by the k-means clustering analysis method. The sensitivity when using a combination of serum markers to detect SPN was higher than that using a single marker. By Fisher discriminant analysis, cytokeratin 19 fragments (CYFRA21-1), carbohydrate antigen 125 (CA125), squamous cell carcinoma antigen (SCC) and breast cancer antigen (CA153), which relate to the benign and malignant SPNs, were screened. Through non-conditional logistic regression analysis, CYFRA21-1, SCC and CA153 were obtained. Using the k-means clustering analysis, the cophenetic correlation coefficient (0.940) obtained by the Fisher discriminant analysis was higher than that obtained with logistic regression analysis (0.875). This study indicated that the Fisher discriminant analysis functioned better in screening out serum markers to recognize the benign and malignant SPN. The combined detection of CYFRA21-1, CA125, SCC and CA153 is an effective way to distinguish benign and malignant SPN, and will find an important clinical application in the early diagnosis of SPN. © 2014 S. Karger GmbH, Freiburg.

  10. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia

    PubMed Central

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-01-01

    Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661

  11. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening

    PubMed Central

    Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric

    2015-01-01

    Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306

  12. Cost-effectiveness analysis of population-based screening of hepatocellular carcinoma: Comparing ultrasonography with two-stage screening

    PubMed Central

    Kuo, Ming-Jeng; Chen, Hsiu-Hsi; Chen, Chi-Ling; Fann, Jean Ching-Yuan; Chen, Sam Li-Sheng; Chiu, Sherry Yueh-Hsia; Lin, Yu-Min; Liao, Chao-Sheng; Chang, Hung-Chuen; Lin, Yueh-Shih; Yen, Amy Ming-Fang

    2016-01-01

    AIM: To assess the cost-effectiveness of two population-based hepatocellular carcinoma (HCC) screening programs, two-stage biomarker-ultrasound method and mass screening using abdominal ultrasonography (AUS). METHODS: In this study, we applied a Markov decision model with a societal perspective and a lifetime horizon for the general population-based cohorts in an area with high HCC incidence, such as Taiwan. The accuracy of biomarkers and ultrasonography was estimated from published meta-analyses. The costs of surveillance, diagnosis, and treatment were based on a combination of published literature, Medicare payments, and medical expenditure at the National Taiwan University Hospital. The main outcome measure was cost per life-year gained with a 3% annual discount rate. RESULTS: The results show that the mass screening using AUS was associated with an incremental cost-effectiveness ratio of USD39825 per life-year gained, whereas two-stage screening was associated with an incremental cost-effectiveness ratio of USD49733 per life-year gained, as compared with no screening. Screening programs with an initial screening age of 50 years old and biennial screening interval were the most cost-effective. These findings were sensitive to the costs of screening tools and the specificity of biomarker screening. CONCLUSION: Mass screening using AUS is more cost effective than two-stage biomarker-ultrasound screening. The most optimal strategy is an initial screening age at 50 years old with a 2-year inter-screening interval. PMID:27022228

  13. High-throughput detection and screening of plants modified by gene editing using quantitative real-time polymerase chain reaction.

    PubMed

    Peng, Cheng; Wang, Hua; Xu, Xiaoli; Wang, Xiaofu; Chen, Xiaoyun; Wei, Wei; Lai, Yongmin; Liu, Guoquan; Godwin, Ian Douglas; Li, Jieqin; Zhang, Ling; Xu, Junfeng

    2018-05-15

    Gene editing techniques are becoming powerful tools for modifying target genes in organisms. Although several methods have been developed to detect gene-edited organisms, these techniques are time and labour intensive. Meanwhile, few studies have investigated high-throughput detection and screening strategies for plants modified by gene editing. In this study, we developed a simple, sensitive and high-throughput quantitative real-time (qPCR)-based method. The qPCR-based method exploits two differently labelled probes that are placed within one amplicon at the gene editing target site to simultaneously detect the wild-type and a gene-edited mutant. We showed that the qPCR-based method can accurately distinguish CRISPR/Cas9-induced mutants from the wild-type in several different plant species, such as Oryza sativa, Arabidopsis thaliana, Sorghum bicolor, and Zea mays. Moreover, the method can subsequently determine the mutation type by direct sequencing of the qPCR products of mutations due to gene editing. The qPCR-based method is also sufficiently sensitive to distinguish between heterozygous and homozygous mutations in T 0 transgenic plants. In a 384-well plate format, the method enabled the simultaneous analysis of up to 128 samples in three replicates without handling the post-polymerase chain reaction (PCR) products. Thus, we propose that our method is an ideal choice for screening plants modified by gene editing from many candidates in T 0 transgenic plants, which will be widely used in the area of plant gene editing. © 2018 The Authors The Plant Journal © 2018 John Wiley & Sons Ltd.

  14. Technologic advances for evaluation of cervical cytology: is newer better?

    PubMed

    Hartmann, K E; Nanda, K; Hall, S; Myers, E

    2001-12-01

    Among those women who have cervical cancer and have been screened, 14% to 33% of the cases represent failure to detect abnormalities that existed at the time of screening. New technologies intended to improve detection of cytologic abnormalities include liquid-based, thin-layer cytology (ThinPrep, AutoCyte), computerized rescreening (PAPNET), and algorithm-based computer rescreening (AutoPap). This report combines evidence reviews conducted for the U.S. Preventive Services Task Force and the Agency for Healthcare Research and Quality, in which we systematically identified articles on cervical neoplasia, cervical dysplasia, and screening published between January 1966 and March 2001. We note the challenges for improving screening methods, providing an overview of methods for collecting and evaluating cytologic samples, and examining the evidence about the diagnostic performance of new technologies for detecting cervical lesions. Using standard criteria for evaluation of the diagnostic tests, we determined that knowledge about the sensitivity, specificity, and predictive values of new technologies is meager. Only one study of liquid-based cytology used a reference standard of colposcopy, with histology as indicated, to assess participants with normal screening results. Lack of an adequate reference standard is the overwhelming reason that test characteristics cannot be properly assessed or compared. Most publications compare results of screening using the new technology with expert panel review of the cytologic specimen. In that case, the tests are not independent measures and do nothing to relate the screening test findings to the true status of the cervix, making determination of false-negatives, and thus sensitivity, specificity, and negative predictive value, impossible. We did not identify any literature about health outcomes or cost effectiveness of using these tools in a system of screening. For the purposes of guiding decision making about choice of screening tools, the current evidence is inadequate to gauge whether new technologies are "better" than conventional cytology..

  15. Budget Impact Analysis of Switching to Digital Mammography in a Population-Based Breast Cancer Screening Program: A Discrete Event Simulation Model

    PubMed Central

    Comas, Mercè; Arrospide, Arantzazu; Mar, Javier; Sala, Maria; Vilaprinyó, Ester; Hernández, Cristina; Cots, Francesc; Martínez, Juan; Castells, Xavier

    2014-01-01

    Objective To assess the budgetary impact of switching from screen-film mammography to full-field digital mammography in a population-based breast cancer screening program. Methods A discrete-event simulation model was built to reproduce the breast cancer screening process (biennial mammographic screening of women aged 50 to 69 years) combined with the natural history of breast cancer. The simulation started with 100,000 women and, during a 20-year simulation horizon, new women were dynamically entered according to the aging of the Spanish population. Data on screening were obtained from Spanish breast cancer screening programs. Data on the natural history of breast cancer were based on US data adapted to our population. A budget impact analysis comparing digital with screen-film screening mammography was performed in a sample of 2,000 simulation runs. A sensitivity analysis was performed for crucial screening-related parameters. Distinct scenarios for recall and detection rates were compared. Results Statistically significant savings were found for overall costs, treatment costs and the costs of additional tests in the long term. The overall cost saving was 1,115,857€ (95%CI from 932,147 to 1,299,567) in the 10th year and 2,866,124€ (95%CI from 2,492,610 to 3,239,638) in the 20th year, representing 4.5% and 8.1% of the overall cost associated with screen-film mammography. The sensitivity analysis showed net savings in the long term. Conclusions Switching to digital mammography in a population-based breast cancer screening program saves long-term budget expense, in addition to providing technical advantages. Our results were consistent across distinct scenarios representing the different results obtained in European breast cancer screening programs. PMID:24832200

  16. Ultrasensitive Single Fluorescence-Labeled Probe-Mediated Single Universal Primer-Multiplex-Droplet Digital Polymerase Chain Reaction for High-Throughput Genetically Modified Organism Screening.

    PubMed

    Niu, Chenqi; Xu, Yuancong; Zhang, Chao; Zhu, Pengyu; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2018-05-01

    As genetically modified (GM) technology develops and genetically modified organisms (GMOs) become more available, GMOs face increasing regulations and pressure to adhere to strict labeling guidelines. A singleplex detection method cannot perform the high-throughput analysis necessary for optimal GMO detection. Combining the advantages of multiplex detection and droplet digital polymerase chain reaction (ddPCR), a single universal primer-multiplex-ddPCR (SUP-M-ddPCR) strategy was proposed for accurate broad-spectrum screening and quantification. The SUP increases efficiency of the primers in PCR and plays an important role in establishing a high-throughput, multiplex detection method. Emerging ddPCR technology has been used for accurate quantification of nucleic acid molecules without a standard curve. Using maize as a reference point, four heterologous sequences ( 35S, NOS, NPTII, and PAT) were selected to evaluate the feasibility and applicability of this strategy. Surprisingly, these four genes cover more than 93% of the transgenic maize lines and serve as preliminary screening sequences. All screening probes were labeled with FAM fluorescence, which allows the signals from the samples with GMO content and those without to be easily differentiated. This fiveplex screening method is a new development in GMO screening. Utilizing an optimal amplification assay, the specificity, limit of detection (LOD), and limit of quantitation (LOQ) were validated. The LOD and LOQ of this GMO screening method were 0.1% and 0.01%, respectively, with a relative standard deviation (RSD) < 25%. This method could serve as an important tool for the detection of GM maize from different processed, commercially available products. Further, this screening method could be applied to other fields that require reliable and sensitive detection of DNA targets.

  17. Cost-effectiveness analysis of universal newborn screening for medium chain acyl-CoA dehydrogenase deficiency in France

    PubMed Central

    2012-01-01

    Background Five diseases are currently screened on dried blood spots in France through the national newborn screening programme. Tandem mass spectrometry (MS/MS) is a technology that is increasingly used to screen newborns for an increasing number of hereditary metabolic diseases. Medium chain acyl-CoA dehydrogenase deficiency (MCADD) is among these diseases. We sought to evaluate the cost-effectiveness of introducing MCADD screening in France. Methods We developed a decision model to evaluate, from a societal perspective and a lifetime horizon, the cost-effectiveness of expanding the French newborn screening programme to include MCADD. Published and, where available, routine data sources were used. Both costs and health consequences were discounted at an annual rate of 4%. The model was applied to a French birth cohort. One-way sensitivity analyses and worst-case scenario simulation were performed. Results We estimate that MCADD newborn screening in France would prevent each year five deaths and the occurrence of neurological sequelae in two children under 5 years, resulting in a gain of 128 life years or 138 quality-adjusted life years (QALY). The incremental cost per year is estimated at €2.5 million, down to €1 million if this expansion is combined with a replacement of the technology currently used for phenylketonuria screening by MS/MS. The resulting incremental cost-effectiveness ratio (ICER) is estimated at €7 580/QALY. Sensitivity analyses indicate that while the results are robust to variations in the parameters, the model is most sensitive to the cost of neurological sequelae, MCADD prevalence, screening effectiveness and screening test cost. The worst-case scenario suggests an ICER of €72 000/QALY gained. Conclusions Although France has not defined any threshold for judging whether the implementation of a health intervention is an efficient allocation of public resources, we conclude that the expansion of the French newborn screening programme to MCADD would appear to be cost-effective. The results of this analysis have been used to produce recommendations for the introduction of universal newborn screening for MCADD in France. PMID:22681855

  18. Ultra-sensitive high performance liquid chromatography-laser-induced fluorescence based proteomics for clinical applications.

    PubMed

    Patil, Ajeetkumar; Bhat, Sujatha; Pai, Keerthilatha M; Rai, Lavanya; Kartha, V B; Chidangil, Santhosh

    2015-09-08

    An ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique has been developed by our group at Manipal, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from volunteers (normal, and different pre-malignant/malignant conditions) were recorded using this set-up. The protein profiles were analyzed using principal component analysis (PCA) to achieve objective detection and classification of malignant, premalignant and healthy conditions with high sensitivity and specificity. The HPLC-LIF protein profiling combined with PCA, as a routine method for screening, diagnosis, and staging of cervical cancer and oral cancer, is discussed in this paper. In recent years, proteomics techniques have advanced tremendously in life sciences and medical sciences for the detection and identification of proteins in body fluids, tissue homogenates and cellular samples to understand biochemical mechanisms leading to different diseases. Some of the methods include techniques like high performance liquid chromatography, 2D-gel electrophoresis, MALDI-TOF-MS, SELDI-TOF-MS, CE-MS and LC-MS techniques. We have developed an ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from healthy and volunteers with different malignant conditions were recorded by using this set-up. The protein profile data were analyzed using principal component analysis (PCA) for objective classification and detection of malignant, premalignant and healthy conditions. The method is extremely sensitive to detect proteins with limit of detection of the order of femto-moles. The HPLC-LIF combined with PCA as a potential proteomic method for the diagnosis of oral cancer and cervical cancer has been discussed in this paper. This article is part of a Special Issue entitled: Proteomics in India. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  20. Factors Influencing Choices for Colorectal Cancer Screening Among Previously Unscreened African and Caucasian Americans: Findings from a Triangulation Mixed Methods Investigation

    PubMed Central

    Ruffin, Mack T.; Creswell, John W.; Jimbo, Masahito

    2014-01-01

    We investigated factors that influence choice of colorectal cancer (CRC) screening test and assessed the most- and least-preferred options among fecal occult blood testing (FOBT), flexible sigmoidoscopy, colonoscopy, and double contrast barium enema among adults with varied race, gender, and geographic region demographics. Mixed methods data collection consisted of 10 focus group interviews and a survey of the 93 focus group participants. Participants were ≥50 years of age and reported not having been screened for colorectal cancer in the last ten years. Analyses examined differences by race, gender, and geographic location. Participants had modest knowledge about CRC and there were fewer correct answers to knowledge questions by African Americans. Participants recognized value of early detection, and identified health symptoms and their doctor's recommendation as influential for obtaining CRC screening. They chose colonoscopy and FOBT as the most preferred tests, while barium enema was least preferred. The analysis revealed intra-group variations in preference, though there were no significant differences by race, gender, or location. Openness of discussing this sensitive topic, lack of knowledge about colorectal cancer and screening costs, and diversity of preferences expressed within study groups suggest the importance of patient-physician dialogue about colorectal cancer screening options. New approaches to promoting colorectal cancer screening need to explore methods to facilitate patients establishing and expressing preferences among the screening options. PMID:19082695

  1. Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2013-01-01

    The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

  2. A high-throughput colorimetric assay for glucose detection based on glucose oxidase-catalyzed enlargement of gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin

    2015-09-01

    We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a

  3. Danish method study on cervical screening in women offered HPV vaccination as girls (Trial23): a study protocol.

    PubMed

    Thamsborg, Lise Holst; Andersen, Berit; Larsen, Lise Grupe; Christensen, Jette; Johansen, Tonje; Hariri, Jalil; Christiansen, Sanne; Rygaard, Carsten; Lynge, Elsebeth

    2018-05-26

    The first birth cohorts of women offered human papillomavirus (HPV) vaccination as girls are now entering cervical screening. However, there is no international consensus on how to screen HPV vaccinated women. These women are better protected against cervical cancer and could therefore be offered less intensive screening. Primary HPV testing is more sensitive than cytology, allowing for a longer screening interval. The aim of Trial23 is to investigate if primary HPV testing with cytology triage of HPV positive samples is a reasonable screening scheme for women offered HPV vaccination as girls. Trial23 is a method study embedded in the existing cervical screening programme in four out of five Danish regions. Without affecting the screening programme, women born in 1994 are randomised to present screening with liquid-based cytology every third year (present programme arm) or present screening plus an HPV test (HPV arm). The study started 1 February 2017 and will run over three screening rounds corresponding to 7-8 years. The primary endpoint is cervical intraepithelial neoplasia grade 3 or above. The trial is undertaken as a non-inferiority study including intention-to-treat and per-protocol analyses. The potential effect of primary HPV screening with a 6-year interval will be calculated from the observed data. The study protocol has been submitted to the ethical committee and deemed a method study. All women are screened according to routine guidelines. The study will contribute new evidence on the future screening of HPV vaccinated birth cohorts of women. All results will be published in open-access journal. NCT03049553; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Frailty Screening Tools for Elderly Patients Incident to Dialysis.

    PubMed

    van Loon, Ismay N; Goto, Namiko A; Boereboom, Franciscus T J; Bots, Michiel L; Verhaar, Marianne C; Hamaker, Marije E

    2017-09-07

    A geriatric assessment is an appropriate method for identifying frail elderly patients. In CKD, it may contribute to optimize personalized care. However, a geriatric assessment is time consuming. The purpose of our study was to compare easy to apply frailty screening tools with the geriatric assessment in patients eligible for dialysis. A total of 123 patients on incident dialysis ≥65 years old were included <3 weeks before to ≤2 weeks after dialysis initiation, and all underwent a geriatric assessment. Patients with impairment in two or more geriatric domains on the geriatric assessment were considered frail. The diagnostic abilities of six frailty screening tools were compared with the geriatric assessment: the Fried Frailty Index, the Groningen Frailty Indicator, Geriatric8, the Identification of Seniors at Risk, the Hospital Safety Program, and the clinical judgment of the nephrologist. Outcome measures were sensitivity, specificity, positive predictive value, and negative predictive value. In total, 75% of patients were frail according to the geriatric assessment. Sensitivity of frailty screening tools ranged from 48% (Fried Frailty Index) to 88% (Geriatric8). The discriminating features of the clinical judgment were comparable with the other screening tools. The Identification of Seniors at Risk screening tool had the best discriminating abilities, with a sensitivity of 74%, a specificity of 80%, a positive predictive value of 91%, and a negative predictive value of 52%. The negative predictive value was poor for all tools, which means that almost one half of the patients screened as fit (nonfrail) had two or more geriatric impairments on the geriatric assessment. All frailty screening tools are able to detect geriatric impairment in elderly patients eligible for dialysis. However, all applied screening tools, including the judgment of the nephrologist, lack the discriminating abilities to adequately rule out frailty compared with a geriatric assessment. Copyright © 2017 by the American Society of Nephrology.

  5. Mixture-based combinatorial libraries from small individual peptide libraries: a case study on α1-antitrypsin deficiency.

    PubMed

    Chang, Yi-Pin; Chu, Yen-Ho

    2014-05-16

    The design, synthesis and screening of diversity-oriented peptide libraries using a "libraries from libraries" strategy for the development of inhibitors of α1-antitrypsin deficiency are described. The major buttress of the biochemical approach presented here is the use of well-established solid-phase split-and-mix method for the generation of mixture-based libraries. The combinatorial technique iterative deconvolution was employed for library screening. While molecular diversity is the general consideration of combinatorial libraries, exquisite design through systematic screening of small individual libraries is a prerequisite for effective library screening and can avoid potential problems in some cases. This review will also illustrate how large peptide libraries were designed, as well as how a conformation-sensitive assay was developed based on the mechanism of the conformational disease. Finally, the combinatorially selected peptide inhibitor capable of blocking abnormal protein aggregation will be characterized by biophysical, cellular and computational methods.

  6. A user-operated test of suprathreshold acuity in noise for adult hearing screening: The SUN (Speech Understanding in Noise) test.

    PubMed

    Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando

    2014-09-01

    A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Screening athletes with Down syndrome for ocular disease.

    PubMed

    Gutstein, Walter; Sinclair, Stephen H; North, Rachel V; Bekiroglu, N

    2010-02-01

    Persons with Down syndrome are well known to have a high prevalence of vision and eye health problems, many of which are undetected or untreated primarily because of infrequent ocular examinations. Public screening programs, directed toward the pediatric population, have become more popular and commonly use letter or symbol charts. This study compares 2 vision screening methods, the Lea Symbol chart and a newly developed interactive computer program, the Vimetrics Central Vision Analyzer (CVA), in their ability to identify ocular disease in the Down syndrome population. Athletes with Down syndrome participating in the European Special Olympics underwent an ocular screening including history, auto-refraction, colour vision assessment, stereopsis assessment, motility assessment, pupil reactivity, and tonometry testing, as well as anterior segment and fundus examinations to evaluate for ocular disease. Visual acuity was tested with the Lea chart and CVA to evaluate these as screening tests for detecting ocular disease as well as significant, uncorrected refractive errors. Among the 91 athletes that presented to the screening, 79 (158 eyes) were sufficiently cooperative for the examination to be completed. Mean age was 26 years +/-10.8 SD. Significant, uncorrected refractive errors (>/=1.00 spherical equivalent) were detected in 28 (18%) eyes and ocular pathology in 51 (32%) eyes. The Lea chart sensitivity and specificity were 43% and 74%, respectively, for detecting ocular pathology and 58% and 100% for detecting uncorrected refractive errors. The CVA sensitivity and specificity were 70% and 86% for detecting pathology and 71% and 100% for detecting uncorrected refractive errors. This study confirmed the findings of prior studies in identifying a significant presence of uncorrected refractive errors and ocular pathology in the Down syndrome population. Screening with the Lea symbol chart found borderline sufficient sensitivity and specificity for the test to be used for screening in this population. The better sensitivity and specificity of the CVA, if adjusted normative values are utilized, appear to make this test sufficient for testing Down syndrome children for identifying both refractive errors and ocular pathology. Copyright 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  8. Comparing Approaches to Optimize Cut-off Scores for Short Cognitive Screening Instruments in Mild Cognitive Impairment and Dementia

    PubMed Central

    O’Caoimh, Rónán; Gao, Yang; Svendovski, Anton; Gallagher, Paul; Eustace, Joseph; Molloy, D. William

    2017-01-01

    Background: Although required to improve the usability of cognitive screening instruments (CSIs), the use of cut-off scores is controversial yet poorly researched. Objective: To explore cut-off scores for two short CSIs: the Standardized Mini-Mental State Examination (SMMSE) and Quick Mild Cognitive Impairment (Qmci) screen, describing adjustments in scores for diagnosis (MCI or dementia), age (≤, >75 years), and education (<, ≥12 years), comparing two methods: the maximal accuracy approach, derived from receiver operating characteristic curves, and Youden’s Index. Methods: Pooled analysis of assessments from patients attending memory clinics in Canada between 1999–2010 : 766 with mild cognitive impairment (MCI) and 1,746 with dementia, and 875 normal controls. Results: The Qmci was more accurate than the SMMSE in differentiating controls from MCI or cognitive impairment (MCI and dementia). Employing the maximal accuracy approach, the optimal SMMSE cut-off for cognitive impairment was <28/30 (AUC 0.86, sensitivity 74%, specificity 88%) versus <63/100 for the Qmci (AUC 0.93, sensitivity 85%, specificity 85%). Using Youden’s Index, the optimal SMMSE cut-off remained <28/30 but fell slightly to <62/100 for the Qmci (sensitivity 83%, specificity 87%). The optimal cut-off for MCI was <29/30 for the SMMSE and <67/100 for the Qmci, irrespective of technique. The maximal accuracy approach generally produced higher Qmci cut-offs than Youden’s Index, both requiring adjustment for age and education. There were no clinically meaningful differences in SMMSE cut-off scores by age and education or method employed. Conclusion: Caution should be exercised selecting cut-offs as these differ by age, education, and method of derivation, with the extent of adjustment varying between CSIs. PMID:28222528

  9. High-performance thin-layer chromatography screening of multi class antibiotics in animal food by bioluminescent bioautography and electrospray ionization mass spectrometry.

    PubMed

    Chen, Yisheng; Schwack, Wolfgang

    2014-08-22

    The world-wide usage and partly abuse of veterinary antibiotics resulted in a pressing need to control residues in animal-derived foods. Large-scale screening for residues of antibiotics is typically performed by microbial agar diffusion tests. This work employing high-performance thin-layer chromatography (HPTLC) combined with bioautography and electrospray ionization mass spectrometry introduces a rapid and efficient method for a multi-class screening of antibiotic residues. The viability of the bioluminescent bacterium Aliivibrio fischeri to the studied antibiotics (16 species of 5 groups) was optimized on amino plates, enabling detection sensitivity down to the strictest maximum residue limits. The HPTLC method was developed not to separate the individual antibiotics, but for cleanup of sample extracts. The studied antibiotics either remained at the start zones (tetracyclines, aminoglycosides, fluoroquinolones, and macrolides) or migrated into the front (amphenicols), while interfering co-extracted matrix compounds were dispersed at hRf 20-80. Only after a few hours, the multi-sample plate image clearly revealed the presence or absence of antibiotic residues. Moreover, molecular information as to the suspected findings was rapidly achieved by HPTLC-mass spectrometry. Showing remarkable sensitivity and matrix-tolerance, the established method was successfully applied to milk and kidney samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Computational diagnosis of canine lymphoma

    NASA Astrophysics Data System (ADS)

    Mirkes, E. M.; Alexandrakis, I.; Slater, K.; Tuli, R.; Gorban, A. N.

    2014-03-01

    One out of four dogs will develop cancer in their lifetime and 20% of those will be lymphoma cases. PetScreen developed a lymphoma blood test using serum samples collected from several veterinary practices. The samples were fractionated and analysed by mass spectrometry. Two protein peaks, with the highest diagnostic power, were selected and further identified as acute phase proteins, C-Reactive Protein and Haptoglobin. Data mining methods were then applied to the collected data for the development of an online computer-assisted veterinary diagnostic tool. The generated software can be used as a diagnostic, monitoring and screening tool. Initially, the diagnosis of lymphoma was formulated as a classification problem and then later refined as a lymphoma risk estimation. Three methods, decision trees, kNN and probability density evaluation, were used for classification and risk estimation and several preprocessing approaches were implemented to create the diagnostic system. For the differential diagnosis the best solution gave a sensitivity and specificity of 83.5% and 77%, respectively (using three input features, CRP, Haptoglobin and standard clinical symptom). For the screening task, the decision tree method provided the best result, with sensitivity and specificity of 81.4% and >99%, respectively (using the same input features). Furthermore, the development and application of new techniques for the generation of risk maps allowed their user-friendly visualization.

  11. Determining Performance Acceptability of Electrochemical Oxygen Sensors

    NASA Technical Reports Server (NTRS)

    Gonzales, Daniel

    2012-01-01

    A method has been developed to screen commercial electrochemical oxygen sensors to reduce the failure rate. There are three aspects to the method: First, the sensitivity over time (several days) can be measured and the rate of change of the sensitivity can be used to predict sensor failure. Second, an improvement to this method would be to store the sensors in an oxygen-free (e.g., nitrogen) environment and intermittently measure the sensitivity over time (several days) to accomplish the same result while preserving the sensor lifetime by limiting consumption of the electrode. Third, the second time derivative of the sensor response over time can be used to determine the point in time at which the sensors are sufficiently stable for use.

  12. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    PubMed

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all <15%. The satisfactory recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  14. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    PubMed

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  15. An Overview on Prenatal Screening for Chromosomal Aberrations.

    PubMed

    Hixson, Lucas; Goel, Srishti; Schuber, Paul; Faltas, Vanessa; Lee, Jessica; Narayakkadan, Anjali; Leung, Ho; Osborne, Jim

    2015-10-01

    This article is a review of current and emerging methods used for prenatal detection of chromosomal aneuploidies. Chromosomal anomalies in the developing fetus can occur in any pregnancy and lead to death prior to or shortly after birth or to costly lifelong disabilities. Early detection of fetal chromosomal aneuploidies, an atypical number of certain chromosomes, can help parents evaluate their pregnancy options. Current diagnostic methods include maternal serum sampling or nuchal translucency testing, which are minimally invasive diagnostics, but lack sensitivity and specificity. The gold standard, karyotyping, requires amniocentesis or chorionic villus sampling, which are highly invasive and can cause abortions. In addition, many of these methods have long turnaround times, which can cause anxiety in mothers. Next-generation sequencing of fetal DNA in maternal blood enables minimally invasive, sensitive, and reasonably rapid analysis of fetal chromosomal anomalies and can be of clinical utility to parents. This review covers traditional methods and next-generation sequencing techniques for diagnosing aneuploidies in terms of clinical utility, technological characteristics, and market potential. © 2015 Society for Laboratory Automation and Screening.

  16. Real-time, label-free monitoring of cell viability based on cell adhesion measurements with an atomic force microscope.

    PubMed

    Yang, Fang; Riedel, René; Del Pino, Pablo; Pelaz, Beatriz; Said, Alaa Hassan; Soliman, Mahmoud; Pinnapireddy, Shashank R; Feliu, Neus; Parak, Wolfgang J; Bakowsky, Udo; Hampp, Norbert

    2017-03-22

    The adhesion of cells to an oscillating cantilever sensitively influences the oscillation amplitude at a given frequency. Even early stages of cytotoxicity cause a change in the viscosity of the cell membrane and morphology, both affecting their adhesion to the cantilever. We present a generally applicable method for real-time, label free monitoring and fast-screening technique to assess early stages of cytotoxicity recorded in terms of loss of cell adhesion. We present data taken from gold nanoparticles of different sizes and surface coatings as well as some reference substances like ethanol, cadmium chloride, and staurosporine. Measurements were recorded with two different cell lines, HeLa and MCF7 cells. The results obtained from gold nanoparticles confirm earlier findings and attest the easiness and effectiveness of the method. The reported method allows to easily adapt virtually every AFM to screen and assess toxicity of compounds in terms of cell adhesion with little modifications as long as a flow cell is available. The sensitivity of the method is good enough indicating that even single cell analysis seems possible.

  17. Current Technologies and Recent Developments for Screening of HPV-Associated Cervical and Oropharyngeal Cancers

    PubMed Central

    Shah, Sunny S.; Senapati, Satyajyoti; Klacsmann, Flora; Miller, Daniel L.; Johnson, Jeff J.; Chang, Hsueh-Chia; Stack, M. Sharon

    2016-01-01

    Mucosal infection by the human papillomavirus (HPV) is responsible for a growing number of malignancies, predominantly represented by cervical cancer and oropharyngeal squamous cell carcinoma. Because of the prevalence of the virus, persistence of infection, and long latency period, novel and low-cost methods are needed for effective population level screening and monitoring. We review established methods for screening of cervical and oral cancer as well as commercially-available techniques for detection of HPV DNA. We then describe the ongoing development of microfluidic nucleic acid-based biosensors to evaluate circulating host microRNAs that are produced in response to an oncogenic HPV infection. The goal is to develop an ideal screening platform that is low-cost, portable, and easy to use, with appropriate signal stability, sensitivity and specificity. Advances in technologies for sample lysis, pre-treatment and concentration, and multiplexed nucleic acid detection are provided. Continued development of these devices provides opportunities for cancer screening in low resource settings, for point-of-care diagnostics and self-screening, and for monitoring response to vaccination or surgical treatment. PMID:27618102

  18. Is early detection of abused children possible?: a systematic review of the diagnostic accuracy of the identification of abused children

    PubMed Central

    2013-01-01

    Background Early detection of abused children could help decrease mortality and morbidity related to this major public health problem. Several authors have proposed tools to screen for child maltreatment. The aim of this systematic review was to examine the evidence on accuracy of tools proposed to identify abused children before their death and assess if any were adapted to screening. Methods We searched in PUBMED, PsycINFO, SCOPUS, FRANCIS and PASCAL for studies estimating diagnostic accuracy of tools identifying neglect, or physical, psychological or sexual abuse of children, published in English or French from 1961 to April 2012. We extracted selected information about study design, patient populations, assessment methods, and the accuracy parameters. Study quality was assessed using QUADAS criteria. Results A total of 2 280 articles were identified. Thirteen studies were selected, of which seven dealt with physical abuse, four with sexual abuse, one with emotional abuse, and one with any abuse and physical neglect. Study quality was low, even when not considering the lack of gold standard for detection of abused children. In 11 studies, instruments identified abused children only when they had clinical symptoms. Sensitivity of tests varied between 0.26 (95% confidence interval [0.17-0.36]) and 0.97 [0.84-1], and specificity between 0.51 [0.39-0.63] and 1 [0.95-1]. The sensitivity was greater than 90% only for three tests: the absence of scalp swelling to identify children victims of inflicted head injury; a decision tool to identify physically-abused children among those hospitalized in a Pediatric Intensive Care Unit; and a parental interview integrating twelve child symptoms to identify sexually-abused children. When the sensitivity was high, the specificity was always smaller than 90%. Conclusions In 2012, there is low-quality evidence on the accuracy of instruments for identifying abused children. Identified tools were not adapted to screening because of low sensitivity and late identification of abused children when they have already serious consequences of maltreatment. Development of valid screening instruments is a pre-requisite before considering screening programs. PMID:24314318

  19. Effective classification of the prevalence of Schistosoma mansoni.

    PubMed

    Mitchell, Shira A; Pagano, Marcello

    2012-12-01

    To present an effective classification method based on the prevalence of Schistosoma mansoni in the community. We created decision rules (defined by cut-offs for number of positive slides), which account for imperfect sensitivity, both with a simple adjustment of fixed sensitivity and with a more complex adjustment of changing sensitivity with prevalence. To reduce screening costs while maintaining accuracy, we propose a pooled classification method. To estimate sensitivity, we use the De Vlas model for worm and egg distributions. We compare the proposed method with the standard method to investigate differences in efficiency, measured by number of slides read, and accuracy, measured by probability of correct classification. Modelling varying sensitivity lowers the lower cut-off more significantly than the upper cut-off, correctly classifying regions as moderate rather than lower, thus receiving life-saving treatment. The classification method goes directly to classification on the basis of positive pools, avoiding having to know sensitivity to estimate prevalence. For model parameter values describing worm and egg distributions among children, the pooled method with 25 slides achieves an expected 89.9% probability of correct classification, whereas the standard method with 50 slides achieves 88.7%. Among children, it is more efficient and more accurate to use the pooled method for classification of S. mansoni prevalence than the current standard method. © 2012 Blackwell Publishing Ltd.

  20. A Simple Method for High Throughput Chemical Screening in Caenorhabditis Elegans

    PubMed Central

    Lucanic, Mark; Garrett, Theo; Gill, Matthew S.; Lithgow, Gordon J.

    2018-01-01

    Caenorhabditis elegans is a useful organism for testing chemical effects on physiology. Whole organism small molecule screens offer significant advantages for identifying biologically active chemical structures that can modify complex phenotypes such as lifespan. Described here is a simple protocol for producing hundreds of 96-well culture plates with fairly consistent numbers of C. elegans in each well. Next, we specified how to use these cultures to screen thousands of chemicals for effects on the lifespan of the nematode C. elegans. This protocol makes use of temperature sensitive sterile strains, agar plate conditions, and simple animal handling to facilitate the rapid and high throughput production of synchronized animal cultures for screening. PMID:29630057

  1. A Functional Assay for GPR55: Envision Protocol.

    PubMed

    Anavi-Goffer, Sharon; Ross, Ruth A

    2016-01-01

    AlphaScreen(®) SureFire(®) assay is a novel technology that combines luminescent oxygen channeling technology, nano-beads, and monocloncal antibodies to detect the level of a selected protein in a volume lower than 5 μl. This method is more sensitive compared with the traditional enzyme-linked immunosorbent assays (ELISA), and can detect an increasing number of new targets. Here, we described a method for AlphaScreen(®) SureFire(®) assay that targets ERK1/2 phosphorylation, a primary downstream signaling pathway that conveys activation of GPR55 by L-α-lysophosphatidylinositol (LPI) and certain cannabinoids.

  2. Integrating Men’s Health and Masculinity Theories to Explain Colorectal Cancer Screening Behavior

    PubMed Central

    Christy, Shannon M.; Mosher, Catherine E.; Rawl, Susan M.

    2013-01-01

    Colorectal cancer (CRC) is the third most common cause of cancer deaths among men in the United States. Although CRC screening has been found to reduce CRC incidence and mortality, current screening rates among men are suboptimal due to various practical and psychosocial barriers. One potential barrier to CRC screening identified in qualitative studies with men is the threat to masculinity that endoscopic screening methods pose. Indeed, beliefs about masculinity have been predictive of other preventive health behaviors among men. In this review paper, we propose a novel conceptual framework to explain men’s CRC screening behavior that integrates masculinity norms, gender role conflict, men’s health care experiences, behaviors, and beliefs, and social and background variables. This framework has the potential to guide future research on men’s CRC screening behaviors and other health behaviors and may inform gender-sensitive interventions which target masculinity beliefs to increase preventive health behaviors. PMID:23813927

  3. Integrating men's health and masculinity theories to explain colorectal cancer screening behavior.

    PubMed

    Christy, Shannon M; Mosher, Catherine E; Rawl, Susan M

    2014-01-01

    Colorectal cancer (CRC) is the third most common cause of cancer deaths among men in the United States. Although CRC screening has been found to reduce CRC incidence and mortality, current screening rates among men are suboptimal due to various practical and psychosocial barriers. One potential barrier to CRC screening identified in qualitative studies with men is the threat to masculinity that endoscopic screening methods pose. Indeed, beliefs about masculinity have been predictive of other preventive health behaviors among men. In this review article, we propose a novel conceptual framework to explain men's CRC screening behavior that integrates masculinity norms, gender role conflict, men's health care experiences, behaviors, and beliefs, and social and background variables. This framework has the potential to guide future research on men's CRC screening behaviors and other health behaviors and may inform gender-sensitive interventions that target masculinity beliefs to increase preventive health behaviors.

  4. Primary Screening for Cervical Cancer Based on High-Risk Human Papillomavirus (HPV) Detection and HPV 16 and HPV 18 Genotyping, in Comparison to Cytology

    PubMed Central

    Constantinidis, Theocharis; Constantinidis, Theodoros C.

    2015-01-01

    Objectives The objective of the present study is to assess the performance of a high-risk human papillomavirus (HR-HPV) DNA test with individual HPV-16/HPV-18 genotyping as a method for primary cervical cancer screening compared with liquid-based cytology (LBC) in a population of Greek women taking part in routine cervical cancer screening. Methods The study, conducted by the “HEllenic Real life Multicentric cErvical Screening” (HERMES) study group, involved the recruitment of 4,009 women, aged 25–55, who took part in routine cervical screening at nine Gynecology Departments in Greece. At first visit cervical specimens were collected for LBC and HPV testing using the Roche Cobas 4800 system. Women found positive for either cytology or HPV were referred for colposcopy, whereas women negative for both tests will be retested after three years. The study is ongoing and the results of the first screening round are reported herein. Results Valid results for cytology and HPV testing were obtained for 3,993 women. The overall prevalence of HR-HPV was 12.7%, of HPV-16 2.7% and of HPV-18 1.4%. Of those referred for colposcopy, cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was detected in 41 women (1.07%). At the threshold of CIN2+, cytology [atypical squamous cells of undetermined significance (ASC-US) or worse] and HPV testing showed a sensitivity of 53.7% and 100% respectively, without change between age groups. Cytology and HPV testing showed specificity of 96.8% and 90.3% respectively, which was increased in older women (≥30) in comparison to younger ones (25–29). Genotyping for HPV16/18 had similar accuracy to cytology for the detection of CIN2+ (sensitivity: 58.5%; specificity 97.5%) as well as for triage to colposcopy (sensitivity: 58.5% vs 53.7% for cytology). Conclusion HPV testing has much better sensitivity than cytology to identify high-grade cervical lesions with slightly lower specificity. HPV testing with individual HPV-16/HPV-18 genotyping could represent a more accurate methodology for primary cervical cancer screening in comparison to liquid-based cytology, especially in older women. PMID:25793281

  5. Public stated preferences and predicted uptake for genome-based colorectal cancer screening

    PubMed Central

    2014-01-01

    Background Emerging developments in nanomedicine allow the development of genome-based technologies for non-invasive and individualised screening for diseases such as colorectal cancer. The main objective of this study was to measure user preferences for colorectal cancer screening using a nanopill. Methods A discrete choice experiment was used to estimate the preferences for five competing diagnostic techniques including the nanopill and iFOBT. Alternative screening scenarios were described using five attributes namely: preparation involved, sensitivity, specificity, complication rate and testing frequency. Fourteen random and two fixed choice tasks, each consisting of three alternatives, were offered to 2225 individuals. Data were analysed using the McFadden conditional logit model. Results Thirteen hundred and fifty-six respondents completed the questionnaire. The most important attributes (and preferred levels) were the screening technique (nanopill), sensitivity (100%) and preparation (no preparation). Stated screening uptake for the nanopill was 79%, compared to 76% for iFOBT. In the case of screening with the nanopill, the percentage of people preferring not to be screened would be reduced from 19.2% (iFOBT) to 16.7%. Conclusions Although the expected benefits of nanotechnology based colorectal cancer screening are improved screening uptake, assuming more accurate test results and less preparation involved, the relative preference of the nanopill is only slightly higher than the iFOBT. Estimating user preferences during the development of diagnostic technologies could be used to identify relative performance, including perceived benefits and harms compared to competitors allowing for significant changes to be made throughout the process of development. PMID:24642027

  6. Results at recruitment from a randomized controlled trial comparing human papillomavirus testing alone with conventional cytology as the primary cervical cancer screening test.

    PubMed

    Ronco, Guglielmo; Giorgi-Rossi, Paolo; Carozzi, Francesca; Confortini, Massimo; Dalla Palma, Paolo; Del Mistro, Annarosa; Gillio-Tos, Anna; Minucci, Daria; Naldoni, Carlo; Rizzolo, Raffaella; Schincaglia, Patrizia; Volante, Renza; Zappa, Marco; Zorzi, Manuel; Cuzick, Jack; Segnan, Nereo

    2008-04-02

    In the first recruitment phase of a randomized trial of cervical cancer screening methods (New Technologies for Cervical Cancer Screening [NTCC] study), we compared screening with conventional cytology with screening by human papillomavirus (HPV) testing in combination with liquid-based cytology. HPV-positive women were directly referred to colposcopy if aged 35 or older; if younger, they were retested after 1 year. In the second recruitment phase of NTCC, we randomly assigned women to conventional cytology (n = 24,661) with referral to colposcopy if cytology indicated atypical squamous cells of undetermined significance or more severe abnormality or to testing for high-risk HPV DNA alone by Hybrid Capture 2 (n = 24,535) with referral to colposcopy if the test was positive at a concentration of HPV DNA 1 pg/mL or greater. For the main endpoint of the study, histologic detection of cervical intraepithelial neoplasia of grade 2 or more (CIN2+), we calculated and compared sensitivity and positive predictive value (PPV) of the two screening methods using HPV DNA cutoffs of 1 pg/mL and 2 pg/mL. All statistical tests were two-sided. For women aged 35-60 years, the relative sensitivity of HPV testing for detection of CIN2+ at a cutoff of 1 pg/mL vs conventional cytology was 1.92 (95% CI = 1.28 to 2.87) and the relative PPV was 0.80 (95% CI = 0.55 to 1.18). At a cutoff of 2 pg/mL HPV DNA, the relative sensitivity was 1.81 (95% CI = 1.20 to 2.72) and the relative PPV was 0.99 (95% CI = 0.67 to 1.46). In this age group, there was no evidence of heterogeneity between study phases. Among women aged 25-34 years, the relative sensitivity for detection of CIN2+ of HPV testing at a cutoff of 1 pg/mL vs cytology was 3.50 (95% CI = 2.11 to 5.82), statistically significantly larger (P = .019) than that observed in phase 1 at this age (1.58; 95% CI = 1.03 to 2.44). For women aged 35-60 years, HPV testing with a cutoff of 2 pg/mL achieves a substantial gain in sensitivity over cytology with only a small reduction in PPV. Among women aged 25-34 years, the large relative sensitivity of HPV testing compared with conventional cytology and the difference between relative sensitivity during phases 1 and 2 suggests that there is frequent regression of CIN2+ that are detected by direct referral of younger HPV-positive women to colposcopy. Thus, triage test or repeat testing is needed if HPV is to be used for primary testing in this context.

  7. The bimanual ovarian palpation examination in the Prostate, Lung, Colorectal and Ovarian cancer screening trial: Performance and complications.

    PubMed

    Doroudi, Maryam; Kramer, Barnett S; Pinsky, Paul F

    2017-12-01

    Objective To provide evidence about the performance characteristics and consequences of bimanual ovarian palpation. Setting and methods The Prostate, Lung, Colorectal and Ovarian cancer screening trial randomized 154,900 individuals to either an intervention or control arm. Enrolled eligible participants were aged 55-74, had no history of trial cancers, and no current treatment for cancer. Intervention arm women received CA-125 tests and transvaginal ultrasound. Bimanual ovarian palpation was offered annually during the first four years of the trial. Bimanual ovarian palpation-specific sensitivity and specificity were calculated, as were rates of diagnostic procedures and resulting complications following positive bimanual ovarian palpation screens. Results A total of 20,872 women received at least one bimanual ovarian palpation, with 50,498 total bimanual ovarian palpation examinations performed. The sensitivity and specificity of bimanual ovarian palpation were 5.1% (2/39) and 99.0% (49,957/50,459), respectively; no cases were detected by bimanual ovarian palpation alone. Rates for most follow-up procedures for abnormal results in women without ovarian cancer were higher among the group with another screening test positive, except for pelvic exam, where rates were similar. No complications were reported in the bimanual ovarian palpation-only positive group. Conclusion Low sensitivity of bimanual ovarian palpation alone and in combination with other tests argue against using bimanual ovarian palpation as a screening test for ovarian cancer in asymptomatic women.

  8. Tension fracture of laminates for transport fuselage. Part 1: Material screening

    NASA Technical Reports Server (NTRS)

    Walker, T. H.; Avery, W. B.; Ilcewicz, L. B.; Poe, C. C., Jr.; Harris, C. E.

    1992-01-01

    Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Application of composites to fuselage structures requires a data base and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity, (2) evaluate composite failure criteria, and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in load bearing plies. Parameters for conventional fracture criteria were found to increase with the crack length of the smallest notch sizes studied. Most materials and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Results indicate that a range of notch sizes must be tested to determine notch sensitivity.

  9. Quantitative assessment model for gastric cancer screening

    PubMed Central

    Chen, Kun; Yu, Wei-Ping; Song, Liang; Zhu, Yi-Min

    2005-01-01

    AIM: To set up a mathematic model for gastric cancer screening and to evaluate its function in mass screening for gastric cancer. METHODS: A case control study was carried on in 66 patients and 198 normal people, then the risk and protective factors of gastric cancer were determined, including heavy manual work, foods such as small yellow-fin tuna, dried small shrimps, squills, crabs, mothers suffering from gastric diseases, spouse alive, use of refrigerators and hot food, etc. According to some principles and methods of probability and fuzzy mathematics, a quantitative assessment model was established as follows: first, we selected some factors significant in statistics, and calculated weight coefficient for each one by two different methods; second, population space was divided into gastric cancer fuzzy subset and non gastric cancer fuzzy subset, then a mathematic model for each subset was established, we got a mathematic expression of attribute degree (AD). RESULTS: Based on the data of 63 patients and 693 normal people, AD of each subject was calculated. Considering the sensitivity and specificity, the thresholds of AD values calculated were configured with 0.20 and 0.17, respectively. According to these thresholds, the sensitivity and specificity of the quantitative model were about 69% and 63%. Moreover, statistical test showed that the identification outcomes of these two different calculation methods were identical (P>0.05). CONCLUSION: The validity of this method is satisfactory. It is convenient, feasible, economic and can be used to determine individual and population risks of gastric cancer. PMID:15655813

  10. Synthetic lethal RNAi screening identifies sensitizing targets for gemcitabine therapy in pancreatic cancer

    PubMed Central

    Azorsa, David O; Gonzales, Irma M; Basu, Gargi D; Choudhary, Ashish; Arora, Shilpi; Bisanz, Kristen M; Kiefer, Jeffrey A; Henderson, Meredith C; Trent, Jeffrey M; Von Hoff, Daniel D; Mousses, Spyro

    2009-01-01

    Background Pancreatic cancer retains a poor prognosis among the gastrointestinal cancers. It affects 230,000 individuals worldwide, has a very high mortality rate, and remains one of the most challenging malignancies to treat successfully. Treatment with gemcitabine, the most widely used chemotherapeutic against pancreatic cancer, is not curative and resistance may occur. Combinations of gemcitabine with other chemotherapeutic drugs or biological agents have resulted in limited improvement. Methods In order to improve gemcitabine response in pancreatic cancer cells, we utilized a synthetic lethal RNAi screen targeting 572 known kinases to identify genes that when silenced would sensitize pancreatic cancer cells to gemcitabine. Results Results from the RNAi screens identified several genes that, when silenced, potentiated the growth inhibitory effects of gemcitabine in pancreatic cancer cells. The greatest potentiation was shown by siRNA targeting checkpoint kinase 1 (CHK1). Validation of the screening results was performed in MIA PaCa-2 and BxPC3 pancreatic cancer cells by examining the dose response of gemcitabine treatment in the presence of either CHK1 or CHK2 siRNA. These results showed a three to ten-fold decrease in the EC50 for CHK1 siRNA-treated cells versus control siRNA-treated cells while treatment with CHK2 siRNA resulted in no change compared to controls. CHK1 was further targeted with specific small molecule inhibitors SB 218078 and PD 407824 in combination with gemcitabine. Results showed that treatment of MIA PaCa-2 cells with either of the CHK1 inhibitors SB 218078 or PD 407824 led to sensitization of the pancreatic cancer cells to gemcitabine. Conclusion These findings demonstrate the effectiveness of synthetic lethal RNAi screening as a tool for identifying sensitizing targets to chemotherapeutic agents. These results also indicate that CHK1 could serve as a putative therapeutic target for sensitizing pancreatic cancer cells to gemcitabine. PMID:19519883

  11. Health economic evaluation of plasma oxysterol screening in the diagnosis of Niemann-Pick Type C disease among intellectually disabled using discrete event simulation.

    PubMed

    van Karnebeek, Clara D M; Mohammadi, Tima; Tsao, Nicole; Sinclair, Graham; Sirrs, Sandra; Stockler, Sylvia; Marra, Carlo

    2015-02-01

    Recently a less invasive method of screening and diagnosing Niemann-Pick C (NP-C) disease has emerged. This approach involves the use of a metabolic screening test (oxysterol assay) instead of the current practice of clinical assessment of patients suspected of NP-C (review of medical history, family history and clinical examination for the signs and symptoms). Our objective is to compare costs and outcomes of plasma oxysterol screening versus current practice in diagnosis of NP-C disease among intellectually disabled (ID) patients using decision-analytic methods. A discrete event simulation model was conducted to follow ID patients through the diagnosis and treatment of NP-C, forecast the costs and effectiveness for a cohort of ID patients and compare the outcomes and costs in two different arms of the model: plasma oxysterol screening and routine diagnosis procedure (anno 2013) over 5 years of follow up. Data from published sources and clinical trials were used in simulation model. Unit costs and quality-adjusted life-years (QALYs) were discounted at a 3% annual rate in the base case analysis. Deterministic and probabilistic sensitivity analyses were conducted. The outcomes of the base case model showed that using plasma oxysterol screening for diagnosis of NP-C disease among ID patients is a dominant strategy. It would result in lower total cost and would slightly improve patients' quality of life. The average amount of cost saving was $3642 CAD and the incremental QALYs per each individual ID patient in oxysterol screening arm versus current practice of diagnosis NP-C was 0.0022 QALYs. Results of sensitivity analysis demonstrated robustness of the outcomes over the wide range of changes in model inputs. Whilst acknowledging the limitations of this study, we conclude that screening ID children and adolescents with oxysterol tests compared to current practice for the diagnosis of NP-C is a dominant strategy with clinical and economic benefits. The less costly, more sensitive and specific oxysterol test has potential to save costs to the healthcare system while improving patients' quality of life and may be considered as a routine tool in the NP-C diagnosis armamentarium for ID. Further research is needed to elucidate its effectiveness in patients presenting characteristics other than ID in childhood and adolescence. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Screening for Victims of Sex Trafficking in the Emergency Department: A Pilot Program

    PubMed Central

    Mumma, Bryn E.; Scofield, Marisa E.; Mendoza, Lydia P.; Toofan, Yalda; Youngyunpipatkul, Justin; Hernandez, Bryan

    2017-01-01

    Introduction Estimates suggest that hundreds of thousands of sex trafficking victims live in the United States. Several screening tools for healthcare professionals to identify sex trafficking victims have been proposed, but the effectiveness of these tools in the emergency department (ED) remains unclear. Our primary objective in this study was to evaluate the feasibility of a screening survey to identify adult victims of sex trafficking in the ED. We also compared the sensitivity of emergency physician concern and a screening survey for identifying sex trafficking victims in the ED and determined the most effective question(s) for identifying adult victims of sex trafficking. Methods We enrolled a convenience sample of medically stable female ED patients, age 18–40 years. Patients completed a 14-question survey. Physician concern for sex trafficking was documented prior to informing the physician of the survey results. A “yes” answer to any question or physician concern was considered a positive screen, and the patient was offered social work consultation. We defined a “true positive” as a patient admission for or social work documentation of sex trafficking. Demographic and clinical information were collected from the electronic medical record. Results We enrolled 143 patients, and of those 39 (27%, 95% confidence interval [CI] [20%–35%]) screened positive, including 10 (25%, 95% CI [13%–41%]) ultimately identified as victims of sex trafficking. Sensitivity of the screening survey (100%, 95% CI [74%–100%]) was better than physician concern (40%, 95% CI [12%–74%]) for identifying victims of sex trafficking, difference 60%, 95% CI [30%–90%]. Physician specificity (91%, 95% CI [85%–95%]), however, was slightly better than the screening survey (78%, 95% CI [70%–85%]), difference 13%, 95% CI [4%–21%]. All 10 (100%, 95%CI [74%–100%]) “true positive” cases answered “yes” to the screening question regarding abuse. Conclusion Identifying adult victims of sex trafficking in the ED is feasible. A screening survey appears to have greater sensitivity than physician concern, and a single screening question may be sufficient to identify all adult victims of sex trafficking in the ED. PMID:28611881

  13. Ovarian Cancer Screening Pilot Trial In High Risk Women — EDRN Public Portal

    Cancer.gov

    BACKGROUND: No proven ovarian cancer (OC) screening strategy exists for women who are at increased risk for the disease. A risk of ovarian cancer algorithm (ROCA) using serial CA125 values have previously shown greater positive predictive value (PPV) and sensitivity than a single CA125 in screening women at general population risk. We hypothesized that using ROCA would yield a reasonable PPV for ovarian cancer screening in a cohort at increased risk. METHODS: Between 7/2001 and 9/2006, 25 sites (14 CGN, 3 ovarian SPOREs, 1 EDRN, 7 others) prospectively enrolled patients. Inclusion criteria included: among self, 1st degree and 2nd degree relatives in same lineage either (i) BRCA 1/2 mutation, or (ii) two of OC or early onset (age 1% to ultrasound (US) and risk > 10% additionally to a gynecologic oncologist. Objectives included PPV for study indicated surgery, sensitivity, and compliance. Sample size was chosen to observe 8 OC endpoints with a power of 80% to rule out PPV < or = 10% if the true PPV = 20%.

  14. Effectiveness of Computer-Aided Detection in Community Mammography Practice

    PubMed Central

    Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.

    2011-01-01

    Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with higher breast cancer detection rates or more favorable stage, size, or lymph node status of invasive breast cancer. Conclusion CAD use during film-screen screening mammography in the United States is associated with decreased specificity but not with improvement in the detection rate or prognostic characteristics of invasive breast cancer. PMID:21795668

  15. Computer-automated dementia screening using a touch-tone telephone.

    PubMed

    Mundt, J C; Ferber, K L; Rizzo, M; Greist, J H

    2001-11-12

    This study investigated the sensitivity and specificity of a computer-automated telephone system to evaluate cognitive impairment in elderly callers to identify signs of early dementia. The Clinical Dementia Rating Scale was used to assess 155 subjects aged 56 to 93 years (n = 74, 27, 42, and 12, with a Clinical Dementia Rating Scale score of 0, 0.5, 1, and 2, respectively). These subjects performed a battery of tests administered by an interactive voice response system using standard Touch-Tone telephones. Seventy-four collateral informants also completed an interactive voice response version of the Symptoms of Dementia Screener. Sixteen cognitively impaired subjects were unable to complete the telephone call. Performances on 6 of 8 tasks were significantly influenced by Clinical Dementia Rating Scale status. The mean (SD) call length was 12 minutes 27 seconds (2 minutes 32 seconds). A subsample (n = 116) was analyzed using machine-learning methods, producing a scoring algorithm that combined performances across 4 tasks. Results indicated a potential sensitivity of 82.0% and specificity of 85.5%. The scoring model generalized to a validation subsample (n = 39), producing 85.0% sensitivity and 78.9% specificity. The kappa agreement between predicted and actual group membership was 0.64 (P<.001). Of the 16 subjects unable to complete the call, 11 provided sufficient information to permit us to classify them as impaired. Standard scoring of the interactive voice response-administered Symptoms of Dementia Screener (completed by informants) produced a screening sensitivity of 63.5% and 100% specificity. A lower criterion found a 90.4% sensitivity, without lowering specificity. Computer-automated telephone screening for early dementia using either informant or direct assessment is feasible. Such systems could provide wide-scale, cost-effective screening, education, and referral services to patients and caregivers.

  16. Modeling screening, prevention, and delaying of Alzheimer's disease: an early-stage decision analytic model.

    PubMed

    Furiak, Nicolas M; Klein, Robert W; Kahle-Wrobleski, Kristin; Siemers, Eric R; Sarpong, Eric; Klein, Timothy M

    2010-04-30

    Alzheimer's Disease (AD) affects a growing proportion of the population each year. Novel therapies on the horizon may slow the progress of AD symptoms and avoid cases altogether. Initiating treatment for the underlying pathology of AD would ideally be based on biomarker screening tools identifying pre-symptomatic individuals. Early-stage modeling provides estimates of potential outcomes and informs policy development. A time-to-event (TTE) simulation provided estimates of screening asymptomatic patients in the general population age > or =55 and treatment impact on the number of patients reaching AD. Patients were followed from AD screen until all-cause death. Baseline sensitivity and specificity were 0.87 and 0.78, with treatment on positive screen. Treatment slowed progression by 50%. Events were scheduled using literature-based age-dependent incidences of AD and death. The base case results indicated increased AD free years (AD-FYs) through delays in onset and a reduction of 20 AD cases per 1000 screened individuals. Patients completely avoiding AD accounted for 61% of the incremental AD-FYs gained. Total years of treatment per 1000 screened patients was 2,611. The number-needed-to-screen was 51 and the number-needed-to-treat was 12 to avoid one case of AD. One-way sensitivity analysis indicated that duration of screening sensitivity and rescreen interval impact AD-FYs the most. A two-way sensitivity analysis found that for a test with an extended duration of sensitivity (15 years) the number of AD cases avoided was 6,000-7,000 cases for a test with higher sensitivity and specificity (0.90,0.90). This study yielded valuable parameter range estimates at an early stage in the study of screening for AD. Analysis identified duration of screening sensitivity as a key variable that may be unavailable from clinical trials.

  17. Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification

    PubMed Central

    Oh, Kyudam; Pak, Nikita; Saunders, D. Curtis; Conrardy, Christina; Landers, James P.; Tong, Suxiang; Forest, Craig R.

    2016-01-01

    Sensitive identification of the etiology of viral diseases is key to implementing appropriate prevention and treatment. The gold standard for virus identification is the polymerase chain reaction (PCR), a technique that allows for highly specific and sensitive detection of pathogens by exponentially amplifying a specific region of DNA from as little as a single copy through thermocycling a biochemical cocktail. Today, molecular biology laboratories use commercial instruments that operate in 0.5–2 h/analysis using reaction volumes of 5–50 μL contained within polymer tubes or chambers. Towards reducing this volume and maintaining performance, we present a semi-quantitative, systematic experimental study of how PCR yield is affected by tube/chamber substrate, surface-area-to-volume ratio (SA:V), and passivation methods. We perform PCR experiments using traditional PCR tubes as well as using disposable polymer microchips with 1 μL reaction volumes thermocycled using water baths. We report the first oil encapsulation microfluidic PCR method without fluid flow and its application to the first microfluidic amplification of Epstein Barr virus using consensus degenerate primers, a powerful and broad PCR method to screen for both known and novel members of a viral family. The limit of detection is measured as 140 starting copies of DNA from a starting concentration of 3×105 copies/mL, regarded as an accepted sensitivity threshold for diagnostic purposes, and reaction specificity was improved as compared to conventional methods. Also notable, these experiments were conducted with conventional reagent concentrations, rather than commonly spiked enzyme and/or template mixtures. This experimental study of the effects of substrate, SA:V, and passivation, together with sensitive and specific microfluidic PCR with consensus degenerate primers represent advances towards lower cost and higher throughput pathogen screening. PMID:23080522

  18. Fecal immunochemical tests in combination with blood tests for colorectal cancer and advanced adenoma detection—systematic review

    PubMed Central

    Niedermaier, Tobias; Weigl, Korbinian; Hoffmeister, Michael; Brenner, Hermann

    2017-01-01

    Background Colorectal cancer (CRC) is a common but largely preventable cancer. Although fecal immunochemical tests (FITs) detect the majority of CRCs, they miss some of the cancers and most advanced adenomas (AAs). The potential of blood tests in complementing FITs for the detection of CRC or AA has not yet been systematically investigated. Methods We conducted a systematic review of performance of FIT combined with an additional blood test for CRC and AA detection versus FIT alone. PubMed and Web of Science were searched until June 9, 2017. Results Some markers substantially increased sensitivity for CRC when combined with FIT, albeit typically at a major loss of specificity. For AA, no relevant increase in sensitivity could be achieved. Conclusion Combining FIT and blood tests might be a promising approach to enhance sensitivity of CRC screening, but comprehensive evaluation of promising marker combinations in screening populations is needed. PMID:29435309

  19. The sensitivity and specificity of the Middlesex Elderly Assessment of Mental State (MEAMS) for detecting cognitive impairment after stroke.

    PubMed

    Cartoni, A; Lincoln, N B

    2005-03-01

    The aim of the study was to assess the sensitivity and specificity of the MEAMS (Golding, 1989) for detecting cognitive impairment after stroke. Stroke patients admitted to hospital received a cognitive screening assessment, the MEAMS, and a detailed cognitive assessment. The information obtained from the detailed assessment was summarised in a structured written report. From the conclusions in these reports, patients were classified as "impaired" or "not impaired" in perception, memory, executive function and language. The sensitivity and specificity of the MEAMS subtests and the overall number of tests passed were determined in relation to the presence of impairment, as given in the overall conclusion of the written reports. There were 30 stroke patients, aged 58 to 92 (mean 75.80, SD 7.94) years. Of these, 17 were men and 13 were women. The sensitivity of the MEAMS subtests ranged from 11% to 100% and the specificity ranged from 69% to 100%. The sensitivity of the overall MEAMS score was 52% and the specificity was 100%, using a cut-off score of 3 or more fails to indicate impairment. Three subtests, Orientation, Naming and Unusual views had 81% sensitivity and 50% specificity for detecting problems in language, perception or memory. The MEAMS was not a sensitive screen for overall cognitive impairment or for memory, perceptual, language, or executive function problems after stroke, but it was specific. Although screening for cognitive impairment is important, the MEAMS is not recommended as the sole method, as it produces an unacceptably high false negative rate. Three subtests (Orientation, Naming and Unusual views) had 81% sensitivity and 50% specificity for detecting cognitive problems in language, perception or memory after stroke.

  20. Three screening methods for cognitive dysfunction using the Mini-Mental State Examination and Korean Dementia Screening Questionnaire.

    PubMed

    Choi, Seong Hye; Park, Moon Ho

    2016-02-01

    To screen for and determine cognitive dysfunction, cognitive tests and/or informant reports are commonly used. However, these cognitive tests and informant reports are not always available. The present study investigated three screening methods using the Mini-Mental State Examination (MMSE) as the cognitive test, and the Korean dementia screening questionnaire (KDSQ) as the informant report. Participants were recruited from the Korea Clinical Research Center for Dementia of South Korea, and included 2861 patients with Alzheimer's disease (dementia), 3519 patients with mild cognitive impairment and 1375 controls with no cognitive dysfunction. Three screening methods were tested: (i) MMSE alone (MMSE(cut-off) ); (ii) a conventional combination of MMSE and KDSQ (MMSE+KDSQ(cut-off) ); and (iii) a decision tree with MMSE and KDSQ (MMSE+KDSQ(decision tree) ). For discriminating any cognitive dysfunction from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.784). For discriminating dementia from controls, MMSE+KDSQ(cut-off) had the highest area under the receiver operating characteristic curve (0.899). For discriminating mild cognitive impairment from controls, MMSE(cut-off) had the highest area under the receiver operating characteristic curve (0.683). MMSE+KDSQ(decision tree) showed the highest sensitivity for all discriminations. For overall classification accuracy, MMSE+KDSQ(decision tree) had the highest value (70.0%). These three methods had different advantageous properties for screening and staging cognitive dysfunction. As there might be different availability across clinical settings, these three methods can be selected and used according to situational needs. © 2015 Japan Geriatrics Society.

  1. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    PubMed Central

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPRfalse-positive rate, sensitivity, and CDRcancer detection rate at all annual interpretive volumes. Conclusion These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow. © RSNA, 2014 Online supplemental material is available for this article. PMID:24960110

  2. Evaluation and recommendation of sensitivity analysis methods for application to Stochastic Human Exposure and Dose Simulation models.

    PubMed

    Mokhtari, Amirhossein; Christopher Frey, H; Zheng, Junyu

    2006-11-01

    Sensitivity analyses of exposure or risk models can help identify the most significant factors to aid in risk management or to prioritize additional research to reduce uncertainty in the estimates. However, sensitivity analysis is challenged by non-linearity, interactions between inputs, and multiple days or time scales. Selected sensitivity analysis methods are evaluated with respect to their applicability to human exposure models with such features using a testbed. The testbed is a simplified version of a US Environmental Protection Agency's Stochastic Human Exposure and Dose Simulation (SHEDS) model. The methods evaluated include the Pearson and Spearman correlation, sample and rank regression, analysis of variance, Fourier amplitude sensitivity test (FAST), and Sobol's method. The first five methods are known as "sampling-based" techniques, wheras the latter two methods are known as "variance-based" techniques. The main objective of the test cases was to identify the main and total contributions of individual inputs to the output variance. Sobol's method and FAST directly quantified these measures of sensitivity. Results show that sensitivity of an input typically changed when evaluated under different time scales (e.g., daily versus monthly). All methods provided similar insights regarding less important inputs; however, Sobol's method and FAST provided more robust insights with respect to sensitivity of important inputs compared to the sampling-based techniques. Thus, the sampling-based methods can be used in a screening step to identify unimportant inputs, followed by application of more computationally intensive refined methods to a smaller set of inputs. The implications of time variation in sensitivity results for risk management are briefly discussed.

  3. Specific and Sensitive Isothermal Electrochemical Biosensor for Plant Pathogen DNA Detection with Colloidal Gold Nanoparticles as Probes

    NASA Astrophysics Data System (ADS)

    Lau, Han Yih; Wu, Haoqi; Wee, Eugene J. H.; Trau, Matt; Wang, Yuling; Botella, Jose R.

    2017-01-01

    Developing quick and sensitive molecular diagnostics for plant pathogen detection is challenging. Herein, a nanoparticle based electrochemical biosensor was developed for rapid and sensitive detection of plant pathogen DNA on disposable screen-printed carbon electrodes. This 60 min assay relied on the rapid isothermal amplification of target pathogen DNA sequences by recombinase polymerase amplification (RPA) followed by gold nanoparticle-based electrochemical assessment with differential pulse voltammetry (DPV). Our method was 10,000 times more sensitive than conventional polymerase chain reaction (PCR)/gel electrophoresis and could readily identify P. syringae infected plant samples even before the disease symptoms were visible. On the basis of the speed, sensitivity, simplicity and portability of the approach, we believe the method has potential as a rapid disease management solution for applications in agriculture diagnostics.

  4. Specific and Sensitive Isothermal Electrochemical Biosensor for Plant Pathogen DNA Detection with Colloidal Gold Nanoparticles as Probes.

    PubMed

    Lau, Han Yih; Wu, Haoqi; Wee, Eugene J H; Trau, Matt; Wang, Yuling; Botella, Jose R

    2017-01-17

    Developing quick and sensitive molecular diagnostics for plant pathogen detection is challenging. Herein, a nanoparticle based electrochemical biosensor was developed for rapid and sensitive detection of plant pathogen DNA on disposable screen-printed carbon electrodes. This 60 min assay relied on the rapid isothermal amplification of target pathogen DNA sequences by recombinase polymerase amplification (RPA) followed by gold nanoparticle-based electrochemical assessment with differential pulse voltammetry (DPV). Our method was 10,000 times more sensitive than conventional polymerase chain reaction (PCR)/gel electrophoresis and could readily identify P. syringae infected plant samples even before the disease symptoms were visible. On the basis of the speed, sensitivity, simplicity and portability of the approach, we believe the method has potential as a rapid disease management solution for applications in agriculture diagnostics.

  5. Component analysis and target cell-based neuroactivity screening of Panax ginseng by ultra-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry.

    PubMed

    Yuan, Jinbin; Chen, Yang; Liang, Jian; Wang, Chong-Zhi; Liu, Xiaofei; Yan, Zhihong; Tang, Yi; Li, Jiankang; Yuan, Chun-Su

    2016-12-01

    Ginseng is one of the most widely used natural medicines in the world. Recent studies have suggested Panax ginseng has a wide range of beneficial effects on aging, central nervous system disorders, and neurodegenerative diseases. However, knowledge about the specific bioactive components of ginseng is still limited. This work aimed to screen for the bioactive components in Panax ginseng that act against neurodegenerative diseases, using the target cell-based bioactivity screening method. Firstly, component analysis of Panax ginseng extracts was performed by UPLC-QTOF-MS, and a total of 54 compounds in white ginseng were characterized and identified according to the retention behaviors, accurate MW, MS characteristics, parent nucleus, aglycones, side chains, and literature data. Then target cell-based bioactivity screening method was developed to predict the candidate compounds in ginseng with SH-SY5Y cells. Four ginsenosides, Rg 2 , Rh 1 , Ro, and Rd, were observed to be active. The target cell-based bioactivity screening method coupled with UPLC-QTOF-MS technique has suitable sensitivity and it can be used as a screening tool for low content bioactive constituents in natural products. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Efficacy of ACL injury risk screening methods in identifying high-risk landing patterns during a sport-specific task.

    PubMed

    Fox, A S; Bonacci, J; McLean, S G; Saunders, N

    2017-05-01

    Screening methods sensitive to movement strategies that increase anterior cruciate ligament (ACL) loads are likely to be effective in identifying athletes at-risk of ACL injury. Current ACL injury risk screening methods are yet to be evaluated for their ability to identify athletes' who exhibit high-risk lower limb mechanics during sport-specific maneuvers associated with ACL injury occurrences. The purpose of this study was to examine the efficacy of two ACL injury risk screening methods in identifying high-risk lower limb mechanics during a sport-specific landing task. Thirty-two female athletes were screened using the Landing Error Scoring System (LESS) and Tuck Jump Assessment. Participants' also completed a sport-specific landing task, during which three-dimensional kinematic and kinetic data were collected. One-dimensional statistical parametric mapping was used to examine the relationships between screening method scores, and the three-dimensional hip and knee joint rotation and moment data from the sport-specific landing. Higher LESS scores were associated with reduced knee flexion from 30 to 57 ms after initial contact (P = 0.003) during the sport-specific landing; however, no additional relationships were found. These findings suggest the LESS and Tuck Jump Assessment may have minimal applicability in identifying athletes' who exhibit high-risk landing postures in the sport-specific task examined. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. An electrochemical immunoassay for the screening of celiac disease in saliva samples.

    PubMed

    Adornetto, Gianluca; Fabiani, Laura; Volpe, Giulia; De Stefano, Alessia; Martini, Sonia; Nenna, Raffaella; Lucantoni, Federica; Bonamico, Margherita; Tiberti, Claudio; Moscone, Danila

    2015-09-01

    A highly sensitive electrochemical immunoassay for the initial diagnosis of celiac disease (CD) in saliva samples that overcomes the problems related to its high viscosity and to the low concentration of anti-transglutaminase antigen (tTG) IgA in this medium has been developed for the first time. The system uses magnetic beads (MBs) covered with tTG, which reacts with the anti-tTG IgA antibodies present in positive saliva samples. An anti-human IgA, conjugated with alkaline phosphate (AP) enzyme, was used as the label and a strip of eight magnetized screen-printed electrodes as the electrochemical transducer. In particular, two different immunoassay approaches were optimized and blindly compared to analyze a large number of saliva samples, whose anti-tTG IgA levels were independently determined by the radioimmunoassay (RIA) method. The obtained results, expressed as Ab index, were used to perform a diagnostic test evaluation through the construction of receiver operating characteristic (ROC) curves. The approach, involving a pre-incubation between the anti-human IgA-AP and saliva samples prior to the addition of MBs-tTG, showed a cutoff of 0.022 with 95% clinical sensitivity and 96% clinical specificity. The area under the ROC curve is equal to 1, a result that classifies our test as "perfect." This study demonstrates that it is possible to perform the screening of CD with a rapid, simple, inexpensive, and sensitive method able to detect anti-tTG antibodies in saliva samples, which are easily obtained by non-invasive techniques. This aspect is of fundamental importance to screen a large number of subjects, especially in the pediatric age.

  8. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  9. Development of an algorithm for phenotypic screening of carbapenemase-producing Enterobacteriaceae in the routine laboratory.

    PubMed

    Robert, Jérôme; Pantel, Alix; Merens, Audrey; Meiller, Elodie; Lavigne, Jean-Philippe; Nicolas-Chanoine, Marie-Hélène

    2017-01-17

    Carbapenemase-producing Enterobacteriaceae (CPE) are difficult to identify among carbapenem non-susceptible Enterobacteriaceae (NSE). We designed phenotypic strategies giving priority to high sensitivity for screening putative CPE before further testing. Presence of carbapenemase-encoding genes in ertapenem NSE (MIC > 0.5 mg/l) consecutively isolated in 80 French laboratories between November 2011 and April 2012 was determined by the Check-MDR-CT103 array method. Using the Mueller-Hinton (MH) disk diffusion method, clinical diameter breakpoints of carbapenems other than ertapenem, piperazicillin+tazobactam, ticarcillin+clavulanate and cefepime as well as diameter cut-offs for these antibiotics and temocillin were evaluated alone or combined to determine their performances (sensitivity, specificity, positive and negative likelihood ratios) for identifying putative CPE among these ertapenem-NSE isolates. To increase the screening specificity, these antibiotics were also tested on cloxacillin-containing MH when carbapenem NSE isolates belonged to species producing chromosomal cephalosporinase (AmpC) but Escherichia coli. Out of the 349 ertapenem NSE, 52 (14.9%) were CPE, including 39 producing OXA-48 group carbapenemase, eight KPC and five MBL. A screening strategy based on the following diameter cut offs, ticarcillin+clavulanate <15 mm, temocillin <15 mm, meropenem or imipenem <22 mm, and cefepime <26 mm, showed 100% sensitivity and 68.1% specificity with the better likelihood ratios combination. The specificity increased when a diameter cut-off <32 mm for imipenem (76.1%) or meropenem (78.8%) further tested on cloxacillin-containing MH was added to the previous strategy for AmpC-producing isolates. The proposed strategies that allowed for increasing the likelihood of CPE among ertapenem-NSE isolates should be considered as a surrogate for carbapenemase production before further CPE confirmatory testing.

  10. Psychophysical Calibration of Mobile Touch-Screens for Vision Testing in the Field

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2015-01-01

    The now ubiquitous nature of touch-screen displays in cell phones and tablet computers makes them an attractive option for vision testing outside of the laboratory or clinic. Accurate measurement of parameters such as contrast sensitivity, however, requires precise control of absolute and relative screen luminances. The nonlinearity of the display response (gamma) can be measured or checked using a minimum motion technique similar to that developed by Anstis and Cavanagh (1983) for the determination of isoluminance. While the relative luminances of the color primaries vary between subjects (due to factors such as individual differences in pre-retinal pigment densities), the gamma nonlinearity can be checked in the lab using a photometer. Here we compare results obtained using the psychophysical method with physical measurements for a number of different devices. In addition, we present a novel physical method using the device's built-in front-facing camera in conjunction with a mirror to jointly calibrate the camera and display. A high degree of consistency between devices is found, but some departures from ideal performance are observed. In spite of this, the effects of calibration errors and display artifacts on estimates of contrast sensitivity are found to be small.

  11. An EEG-based machine learning method to screen alcohol use disorder.

    PubMed

    Mumtaz, Wajid; Vuong, Pham Lam; Xia, Likun; Malik, Aamir Saeed; Rashid, Rusdi Bin Abd

    2017-04-01

    Screening alcohol use disorder (AUD) patients has been challenging due to the subjectivity involved in the process. Hence, robust and objective methods are needed to automate the screening of AUD patients. In this paper, a machine learning method is proposed that utilized resting-state electroencephalography (EEG)-derived features as input data to classify the AUD patients and healthy controls and to perform automatic screening of AUD patients. In this context, the EEG data were recorded during 5 min of eyes closed and 5 min of eyes open conditions. For this purpose, 30 AUD patients and 15 aged-matched healthy controls were recruited. After preprocessing the EEG data, EEG features such as inter-hemispheric coherences and spectral power for EEG delta, theta, alpha, beta and gamma bands were computed involving 19 scalp locations. The selection of most discriminant features was performed with a rank-based feature selection method assigning a weight value to each feature according to a criterion, i.e., receiver operating characteristics curve. For example, a feature with large weight was considered more relevant to the target labels than a feature with less weight. Therefore, a reduced set of most discriminant features was identified and further be utilized during classification of AUD patients and healthy controls. As results, the inter-hemispheric coherences between the brain regions were found significantly different between the study groups and provided high classification efficiency ( Accuracy  = 80.8, sensitivity  = 82.5, and specificity  = 80, F - Measure  = 0.78). In addition, the power computed in different EEG bands were found significant and provided an overall classification efficiency as ( Accuracy  = 86.6, sensitivity  = 95, specificity  = 82.5, and F - Measure  = 0.88). Further, the integration of these EEG feature resulted into even higher results ( Accuracy  = 89.3 %, sensitivity  = 88.5 %, specificity  = 91 %, and F - Measure  = 0.90). Based on the results, it is concluded that the EEG data (integration of the theta, beta, and gamma power and inter-hemispheric coherence) could be utilized as objective markers to screen the AUD patients and healthy controls.

  12. Evaluation of the Utility of Screening Mammography for High-Risk Women Undergoing Screening Breast MR Imaging.

    PubMed

    Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel

    2017-10-01

    Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.

  13. Binding-Site Assessment by Virtual Fragment Screening

    PubMed Central

    Huang, Niu; Jacobson, Matthew P.

    2010-01-01

    The accurate prediction of protein druggability (propensity to bind high-affinity drug-like small molecules) would greatly benefit the fields of chemical genomics and drug discovery. We have developed a novel approach to quantitatively assess protein druggability by computationally screening a fragment-like compound library. In analogy to NMR-based fragment screening, we dock ∼11000 fragments against a given binding site and compute a computational hit rate based on the fraction of molecules that exceed an empirically chosen score cutoff. We perform a large-scale evaluation of the approach on four datasets, totaling 152 binding sites. We demonstrate that computed hit rates correlate with hit rates measured experimentally in a previously published NMR-based screening method. Secondly, we show that the in silico fragment screening method can be used to distinguish known druggable and non-druggable targets, including both enzymes and protein-protein interaction sites. Finally, we explore the sensitivity of the results to different receptor conformations, including flexible protein-protein interaction sites. Besides its original aim to assess druggability of different protein targets, this method could be used to identifying druggable conformations of flexible binding site for lead discovery, and suggesting strategies for growing or joining initial fragment hits to obtain more potent inhibitors. PMID:20404926

  14. Development of a Test of Suprathreshold Acuity in Noise in Brazilian Portuguese: A New Method for Hearing Screening and Surveillance

    PubMed Central

    Vaez, Nara; Desgualdo-Pereira, Liliane; Paglialonga, Alessia

    2014-01-01

    This paper describes the development of a speech-in-noise test for hearing screening and surveillance in Brazilian Portuguese based on the evaluation of suprathreshold acuity performances. The SUN test (Speech Understanding in Noise) consists of a list of intervocalic consonants in noise presented in a multiple-choice paradigm by means of a touch screen. The test provides one out of three possible results: “a hearing check is recommended” (red light), “a hearing check would be advisable” (yellow light), and “no hearing difficulties” (green light) (Paglialonga et al., Comput. Biol. Med. 2014). This novel test was developed in a population of 30 normal hearing young adults and 101 adults with varying degrees of hearing impairment and handicap, including normal hearing. The test had 84% sensitivity and 76% specificity compared to conventional pure-tone screening and 83% sensitivity and 86% specificity to detect disabling hearing impairment. The test outcomes were in line with the degree of self-perceived hearing handicap. The results found here paralleled those reported in the literature for the SUN test and for conventional speech-in-noise measures. This study showed that the proposed test might be a viable method to identify individuals with hearing problems to be referred to further audiological assessment and intervention. PMID:25247181

  15. Application of Abbreviated Protocol of Magnetic Resonance Imaging for Breast Cancer Screening in Dense Breast Tissue.

    PubMed

    Chen, Shuang-Qing; Huang, Min; Shen, Yu-Ying; Liu, Chen-Lu; Xu, Chuan-Xiao

    2017-03-01

    The study aimed to evaluate the usefulness of an abbreviated protocol (AP) of magnetic resonance imaging (MRI) in comparison to a full diagnostic protocol (FDP) of MRI in the breast cancer screening with dense breast tissue. There are 478 female participants with dense breast tissue and negative mammography results, who were imaged with MRI using AP and FDP. The AP and FDP images were analyzed separately, and the sensitivity and specificity of breast cancer detection were calculated. The chi-square test and receiver operating characteristics curves were used to assess the breast cancer diagnostic capabilities of the two protocols. Sixteen cases of breast cancer from 478 patients with dense breasts were detected using the FDP method, with pathologic confirmation of nine cases of ductal carcinoma in situ, six cases of invasive ductal carcinoma, and one case of mucinous carcinoma. Fifteen cases of breast cancer were successfully screened using the AP method. The sensitivity showed no obvious significant difference between AP and FDP (χ 2  = 0.592, P = 0.623), but the specificity showed a statistically significant difference (χ 2  = 4.619, P = 0.036). The receiver operating characteristics curves showed high efficacy of both methods in the detection of breast cancer in dense breast tissue (the areas under the curve were 0.931 ± 0.025 and 0.947 ± 0.024, respectively), and the ability to diagnose breast cancer was not statistically significantly different between the two methods. The AP of MRI may improve the detection rate of breast cancer in dense breast tissue, and it may be useful in efficient breast cancer screening. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. The efficacy of semi-quantitative urine protein-to-creatinine (P/C) ratio for the detection of significant proteinuria in urine specimens in health screening settings.

    PubMed

    Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh

    2016-01-01

    Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.

  17. Validation of an ELISA Synthetic Cannabinoids Urine Assay

    PubMed Central

    Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.

    2015-01-01

    Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046

  18. Time-lapse imaging assay using the BioStation CT: a sensitive drug-screening method for three-dimensional cell culture.

    PubMed

    Sakamoto, Ruriko; Rahman, M Mamunur; Shimomura, Manami; Itoh, Manabu; Nakatsura, Tetsuya

    2015-06-01

    Three-dimensional (3D) cell culture is beneficial for physiological studies of tumor cells, due to its potential to deliver a high quantity of cell culture information that is representative of the cancer microenvironment and predictive of drug responses in vivo. Currently, gel-associated or matrix-associated 3D cell culture is comprised of intricate procedures that often result in experimental complexity. Therefore, we developed an innovative anti-cancer drug sensitivity screening technique for 3D cell culture on NanoCulture Plates (NCP) by employing the imaging device BioStation CT. Here, we showed that the human breast cancer cell lines BT474 and T47D form multicellular spheroids on NCP plates and compared their sensitivity to the anti-cancer drugs trastuzumab and paclitaxel using the BioStation CT. The anticancer drugs reduced spheroid migration velocity and suppressed spheroid fusion. In addition, primary cells derived from the human breast cancer tissues B58 and B61 grown on NCP plates also exhibited similar drug sensitivity. These results were in good agreement with the conventional assay method using ATP quantification. We confirmed the antitumor effects of the drugs on cells seeded in 96-well plates using the BioStation CT imaging technique. We expect this method to be useful in research for new antitumor agents and for drug sensitivity tests in individually-tailored cancer treatments. © 2015 The Authors. Cancer Science published by Wiley Publishing Asia Pty Ltd on behalf of Japanese Cancer Association.

  19. A Metric for Reducing False Positives in the Computer-Aided Detection of Breast Cancer from Dynamic Contrast-Enhanced Magnetic Resonance Imaging Based Screening Examinations of High-Risk Women.

    PubMed

    Levman, Jacob E D; Gallego-Ortiz, Cristina; Warner, Ellen; Causer, Petrina; Martel, Anne L

    2016-02-01

    Magnetic resonance imaging (MRI)-enabled cancer screening has been shown to be a highly sensitive method for the early detection of breast cancer. Computer-aided detection systems have the potential to improve the screening process by standardizing radiologists to a high level of diagnostic accuracy. This retrospective study was approved by the institutional review board of Sunnybrook Health Sciences Centre. This study compares the performance of a proposed method for computer-aided detection (based on the second-order spatial derivative of the relative signal intensity) with the signal enhancement ratio (SER) on MRI-based breast screening examinations. Comparison is performed using receiver operating characteristic (ROC) curve analysis as well as free-response receiver operating characteristic (FROC) curve analysis. A modified computer-aided detection system combining the proposed approach with the SER method is also presented. The proposed method provides improvements in the rates of false positive markings over the SER method in the detection of breast cancer (as assessed by FROC analysis). The modified computer-aided detection system that incorporates both the proposed method and the SER method yields ROC results equal to that produced by SER while simultaneously providing improvements over the SER method in terms of false positives per noncancerous exam. The proposed method for identifying malignancies outperforms the SER method in terms of false positives on a challenging dataset containing many small lesions and may play a useful role in breast cancer screening by MRI as part of a computer-aided detection system.

  20. Methicillin-Resistant and Methicillin-Sensitive Staphylococcus aureus Screening and Decolonization to Reduce Surgical Site Infection in Elective Total Joint Arthroplasty.

    PubMed

    Sporer, Scott M; Rogers, Thea; Abella, Linda

    2016-09-01

    Deep infection after elective total joint arthroplasty remains a devastating complication. Preoperative nasal swab screening for Staphylococcus aureus colonization and subsequent treatment of colonized patients is one proposed method to identify at-risk patients and decrease surgical site infections (SSIs). The purpose of this study was to determine whether a preoperative staphylococcus screening and treatment program would decrease the incidence of SSI in elective joint arthroplasty patients. Since January 2009, a total of 9690 patients having an elective joint arthroplasty were screened before surgery for Methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-sensitive Staphylococcus aureus (MSSA) with nares swabs. All patients with positive nare colonization for MSSA and MRSA were treated with mupirocin and chlorhexidine gluconate showers for 5 days before surgery. MRSA patients received vancomycin preoperatively and were placed in contact isolation. All elective arthroplasty patients used chlorhexidine gluconate antiseptic cloths the evening prior and the day of surgery. Perioperative infection rates were compared from 1 year before implementation to 5 years after implementation of this screening protocol. SSI rates have decreased from 1.11% (prescreening) to 0.34% (nasal screening; P < .05) after initiation of the process. Staphylococcus was identified in 66.7% of the SSI infections before nasal screening and in 33.3% of the SSI after routine screening (P > .05). The addition of MRSA and/or MSSA nares screening along with a perioperative decolonization protocol has resulted in a decreased SSI rate by 69%. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. High-resolution melting (HRM) re-analysis of a polyposis patients cohort reveals previously undetected heterozygous and mosaic APC gene mutations.

    PubMed

    Out, Astrid A; van Minderhout, Ivonne J H M; van der Stoep, Nienke; van Bommel, Lysette S R; Kluijt, Irma; Aalfs, Cora; Voorendt, Marsha; Vossen, Rolf H A M; Nielsen, Maartje; Vasen, Hans F A; Morreau, Hans; Devilee, Peter; Tops, Carli M J; Hes, Frederik J

    2015-06-01

    Familial adenomatous polyposis is most frequently caused by pathogenic variants in either the APC gene or the MUTYH gene. The detection rate of pathogenic variants depends on the severity of the phenotype and sensitivity of the screening method, including sensitivity for mosaic variants. For 171 patients with multiple colorectal polyps without previously detectable pathogenic variant, APC was reanalyzed in leukocyte DNA by one uniform technique: high-resolution melting (HRM) analysis. Serial dilution of heterozygous DNA resulted in a lowest detectable allelic fraction of 6% for the majority of variants. HRM analysis and subsequent sequencing detected pathogenic fully heterozygous APC variants in 10 (6%) of the patients and pathogenic mosaic variants in 2 (1%). All these variants were previously missed by various conventional scanning methods. In parallel, HRM APC scanning was applied to DNA isolated from polyp tissue of two additional patients with apparently sporadic polyposis and without detectable pathogenic APC variant in leukocyte DNA. In both patients a pathogenic mosaic APC variant was present in multiple polyps. The detection of pathogenic APC variants in 7% of the patients, including mosaics, illustrates the usefulness of a complete APC gene reanalysis of previously tested patients, by a supplementary scanning method. HRM is a sensitive and fast pre-screening method for reliable detection of heterozygous and mosaic variants, which can be applied to leukocyte and polyp derived DNA.

  2. Direct Identification of On-Bead Peptides Using Surface-Enhanced Raman Spectroscopic Barcoding System for High-Throughput Bioanalysis

    PubMed Central

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-01-01

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery. PMID:26017924

  3. Direct identification of on-bead peptides using surface-enhanced Raman spectroscopic barcoding system for high-throughput bioanalysis.

    PubMed

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-05-28

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery.

  4. Comparison of Enzyme-Linked Immunosorbent Assay, Surface Plasmon Resonance and Biolayer Interferometry for Screening of Deoxynivalenol in Wheat and Wheat Dust.

    PubMed

    Sanders, Melanie; McPartlin, Daniel; Moran, Kara; Guo, Yirong; Eeckhout, Mia; O'Kennedy, Richard; De Saeger, Sarah; Maragos, Chris

    2016-04-11

    A sample preparation method was developed for the screening of deoxynivalenol (DON) in wheat and wheat dust. Extraction was carried out with water and was successful due to the polar character of DON. For detection, an enzyme-linked immunosorbent assay (ELISA) was compared to the sensor-based techniques of surface plasmon resonance (SPR) and biolayer interferometry (BLI) in terms of sensitivity, affinity and matrix effect. The matrix effects from wheat and wheat dust using SPR were too high to further use this screenings method. The preferred ELISA and BLI methods were validated according to the criteria established in Commission Regulation 519/2014/EC and Commission Decision 2002/657/EC. A small survey was executed on 16 wheat lots and their corresponding dust samples using the validated ELISA method. A linear correlation (r = 0.889) was found for the DON concentration in dust versus the DON concentration in wheat (LOD wheat: 233 μg/kg, LOD wheat dust: 458 μg/kg).

  5. Sensitivity, Specificity, and Predictive Values: Foundations, Pliabilities, and Pitfalls in Research and Practice.

    PubMed

    Trevethan, Robert

    2017-01-01

    Within the context of screening tests, it is important to avoid misconceptions about sensitivity, specificity, and predictive values. In this article, therefore, foundations are first established concerning these metrics along with the first of several aspects of pliability that should be recognized in relation to those metrics. Clarification is then provided about the definitions of sensitivity, specificity, and predictive values and why researchers and clinicians can misunderstand and misrepresent them. Arguments are made that sensitivity and specificity should usually be applied only in the context of describing a screening test's attributes relative to a reference standard; that predictive values are more appropriate and informative in actual screening contexts, but that sensitivity and specificity can be used for screening decisions about individual people if they are extremely high; that predictive values need not always be high and might be used to advantage by adjusting the sensitivity and specificity of screening tests; that, in screening contexts, researchers should provide information about all four metrics and how they were derived; and that, where necessary, consumers of health research should have the skills to interpret those metrics effectively for maximum benefit to clients and the healthcare system.

  6. Sensitivity, Specificity, and Predictive Values: Foundations, Pliabilities, and Pitfalls in Research and Practice

    PubMed Central

    Trevethan, Robert

    2017-01-01

    Within the context of screening tests, it is important to avoid misconceptions about sensitivity, specificity, and predictive values. In this article, therefore, foundations are first established concerning these metrics along with the first of several aspects of pliability that should be recognized in relation to those metrics. Clarification is then provided about the definitions of sensitivity, specificity, and predictive values and why researchers and clinicians can misunderstand and misrepresent them. Arguments are made that sensitivity and specificity should usually be applied only in the context of describing a screening test’s attributes relative to a reference standard; that predictive values are more appropriate and informative in actual screening contexts, but that sensitivity and specificity can be used for screening decisions about individual people if they are extremely high; that predictive values need not always be high and might be used to advantage by adjusting the sensitivity and specificity of screening tests; that, in screening contexts, researchers should provide information about all four metrics and how they were derived; and that, where necessary, consumers of health research should have the skills to interpret those metrics effectively for maximum benefit to clients and the healthcare system. PMID:29209603

  7. Screening and determination of polycyclic aromatic hydrocarbons in seafoods using QuEChERS-based extraction and high-performance liquid chromatography with fluorescence detection.

    PubMed

    Gratz, Samuel R; Ciolino, Laura A; Mohrhaus, Angela S; Gamble, Bryan M; Gracie, Jill M; Jackson, David S; Roetting, John P; McCauley, Heather A; Heitkemper, Douglas T; Fricke, Fred L; Krol, Walter J; Arsenault, Terri L; White, Jason C; Flottmeyer, Michele M; Johnson, Yoko S

    2011-01-01

    A rapid, sensitive, and accurate method for the screening and determination of polycyclic aromatic hydrocarbons (PAHs) in edible seafood is described. The method uses quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based extraction and HPLC with fluorescence detection (FLD). The method was developed and validated in response to the massive Deepwater Horizon oil spill in the Gulf of Mexico. Rapid and highly sensitive PAH screening methods are critical tools needed for oil spill response; they help to assess when seafood is safe for harvesting and consumption. Sample preparation involves SPE of edible seafood portions with acetonitrile, followed by the addition of salts to induce water partitioning. After centrifugation, a portion of the acetonitrile layer is filtered prior to analysis via HPLC-FLD. The chromatographic method uses a polymeric C18 stationary phase designed for PAH analysis with gradient elution, and it resolves 15 U.S. Environmental Protection Agency priority parent PAHs in fewer than 20 min. The procedure was validated in three laboratories for the parent PAHs using spike recovery experiments at PAH fortification levels ranging from 25 to 10 000 microg/kg in oysters, shrimp, crab, and finfish, with recoveries ranging from 78 to 99%. Additional validation was conducted for a series of alkylated homologs of naphthalene, dibenzothiophene, and phenanthrene, with recoveries ranging from 87 to 128%. Method accuracy was further assessed based on analysis of National Institute of Standards and Technology Standard Reference Material 1974b. The method provides method detection limits in the sub to low ppb (microg/kg) range, and practical LOQs in the low ppb (microg/kg) range for most of the PAH compounds studied.

  8. Anaemia in pregnancy in the district of Anuradhapura, Sri Lanka--need for updating prevalence data and screening strategies.

    PubMed

    Chathurani, U; Dharshika, I; Galgamuwa, D; Wickramasinghe, N D; Agampodi, T C; Agampodi, S B

    2012-09-01

    To determine the prevalence of anaemia during pregnancy in Anuradhapura district and evaluate present screening methods for anaemia. Modified WHO 30 cluster sampling method with increased precision was used to estimate the prevalence of anaemia in the Anuradhapura district, Sri Lanka. Serum haemoglobin was measured using methemoglobin method. Clinical examination was carried out to evaluate the conjunctival method in anaemia screening. Values recorded from haemoglobin colour scale method used in the field antenatal clinics were collected. A total of 990 pregnant women participated in the study. In the first, second and third trimesters, prevalence of anaemia was 7.6%, 19.7% and 19.3% respectively. Gestational age adjusted anaemia prevalence among pregnant women in this study population was 14.1% (95% CI 12.0-16.4%). Mean and median haemoglobin concentration of the study sample was 11.8g/dL (SD 1.02g/dl and IQR 11.2-12.5g/dl). Among anaemic pregnant women, average values for Mean Corpuscular Volume (MCV), Mean Corpuscular Haemoglobin (MCH), and Mean Corpuscular Haemoglobin Concentration (MCHC) were, 82.9 fl (SD 11.5), 27.6 (SD-3.6) pg/cell and 32.9g/dl (SD 1.8) respectively. Sensitivity and specificity of haemoglobin colour scale method was 50% (95% CI 29.0-71.0%) and 76.3% (95% CI 66.9-83.7%) respectively. Sensitivity and specificity of conjunctival method in detecting anaemia during pregnancy was 18.8% (95% CI 11.9-28.4) and 69.3% (95% CI 58.2- 78.6%). Prevalence of anaemia in the district of Anuradhapura was less than 50% of the estimated prevalence for Sri Lanka. Both haemoglobin colour scale and conjunctival method were having low validity in detecting anaemia in pregnancy.

  9. An electronic screen for triaging adolescent substance use by risk levels.

    PubMed

    Levy, Sharon; Weiss, Roger; Sherritt, Lon; Ziemnik, Rosemary; Spalding, Allegra; Van Hook, Shari; Shrier, Lydia A

    2014-09-01

    Screening adolescents for substance use and intervening immediately can reduce the burden of addiction and substance-related morbidity. Several screening tools have been developed to identify problem substance use for adolescents, but none have been calibrated to triage adolescents into clinically relevant risk categories to guide interventions. To describe the psychometric properties of an electronic screen and brief assessment tool that triages adolescents into 4 actionable categories regarding their experience with nontobacco substance use. Adolescent patients (age range, 12-17 years) arriving for routine medical care at 2 outpatient primary care centers and 1 outpatient center for substance use treatment at a pediatric hospital completed an electronic screening tool from June 1, 2012, through March 31, 2013, that consisted of a question on the frequency of using 8 types of drugs in the past year (Screening to Brief Intervention). Additional questions assessed severity of any past-year substance use. Patients completed a structured diagnostic interview (Composite International Diagnostic Interview-Substance Abuse Module), yielding Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) substance use diagnoses. For the entire screen and the Screening to Brief Intervention, sensitivity and specificity for identifying nontobacco substance use, substance use disorders, severe substance use disorders, and tobacco dependence were calculated using the Composite International Diagnostic Interview-Substance Abuse Module as the criterion standard. Of 340 patients invited to participate, 216 (63.5%) enrolled in the study. Sensitivity and specificity were 100% and 84% (95% CI, 76%-89%) for identifying nontobacco substance use, 90% (95% CI, 77%-96%) and 94% (95% CI, 89%-96%) for substance use disorders, 100% and 94% (95% CI, 90%-96%) for severe substance use disorders, and 75% (95% CI, 52%-89%) and 98% (95% CI, 95%-100%) for nicotine dependence. No significant differences were found in sensitivity or specificity between the full tool and the Screening to Brief Intervention. A single screening question assessing past-year frequency use for 8 commonly misused categories of substances appears to be a valid method for discriminating among clinically relevant risk categories of adolescent substance use.

  10. An Electronic Screen for Triaging Adolescent Substance Use by Risk Levels

    PubMed Central

    Levy, Sharon; Weiss, Roger; Sherritt, Lon; Ziemnik, Rosemary; Spalding, Allegra; Van Hook, Shari; Shrier, Lydia A.

    2014-01-01

    IMPORTANCE Screening adolescents for substance use and intervening immediately can reduce the burden of addiction and substance-related morbidity. Several screening tools have been developed to identify problem substance use for adolescents, but none have been calibrated to triage adolescents into clinically relevant risk categories to guide interventions. OBJECTIVE To describe the psychometric properties of an electronic screen and brief assessment tool that triages adolescents into 4 actionable categories regarding their experience with nontobacco substance use. DESIGN, SETTING, AND PARTICIPANTS Adolescent patients (age range, 12–17 years) arriving for routine medical care at 2 outpatient primary care centers and 1 outpatient center for substance use treatment at a pediatric hospital completed an electronic screening tool from June 1, 2012, through March 31, 2013, that consisted of a question on the frequency of using 8 types of drugs in the past year (Screening to Brief Intervention). Additional questions assessed severity of any past-year substance use. Patients completed a structured diagnostic interview (Composite International Diagnostic Interview–Substance Abuse Module), yielding Diagnostic and Statistical Manual of Mental Disorders (Fifth Edition) substance use diagnoses. MAIN OUTCOMES AND MEASURES For the entire screen and the Screening to Brief Intervention, sensitivity and specificity for identifying nontobacco substance use, substance use disorders, severe substance use disorders, and tobacco dependence were calculated using the Composite International Diagnostic Interview–Substance Abuse Module as the criterion standard. RESULTS Of 340 patients invited to participate, 216 (63.5%) enrolled in the study. Sensitivity and specificity were 100% and 84%(95%CI, 76%–89%) for identifying nontobacco substance use, 90% (95%CI, 77%–96%) and 94%(95%CI, 89%–96%) for substance use disorders, 100% and 94%(95%CI, 90%–96%) for severe substance use disorders, and 75% (95%CI, 52%–89%) and 98%(95%CI, 95%–100%) for nicotine dependence. No significant differences were found in sensitivity or specificity between the full tool and the Screening to Brief Intervention. CONCLUSIONS AND RELEVANCE A single screening question assessing past-year frequency use for 8 commonly misused categories of substances appears to be a valid method for discriminating among clinically relevant risk categories of adolescent substance use. PMID:25070067

  11. Comparison of sensitivity of lung nodule detection between radiologists and technologists on low-dose CT lung cancer screening images

    PubMed Central

    Kakinuma, R; Ashizawa, K; Kobayashi, T; Fukushima, A; Hayashi, H; Kondo, T; Machida, M; Matsusako, M; Minami, K; Oikado, K; Okuda, M; Takamatsu, S; Sugawara, M; Gomi, S; Muramatsu, Y; Hanai, K; Muramatsu, Y; Kaneko, M; Tsuchiya, R; Moriyama, N

    2012-01-01

    Objectives The objective of this study was to compare the sensitivity of detection of lung nodules on low-dose screening CT images between radiologists and technologists. Methods 11 radiologists and 10 technologists read the low-dose screening CT images of 78 subjects. On images with a slice thickness of 5 mm, there were 60 lung nodules that were ≥5 mm in diameter: 26 nodules with pure ground-glass opacity (GGO), 7 nodules with mixed ground-glass opacity (GGO with a solid component) and 27 solid nodules. On images with a slice thickness of 2 mm, 69 lung nodules were ≥5 mm in diameter: 35 pure GGOs, 7 mixed GGOs and 27 solid nodules. The 21 observers read screening CT images of 5-mm slice thickness at first; then, 6 months later, they read screening CT images of 2-mm slice thickness from the 78 subjects. Results The differences in the mean sensitivities of detection of the pure GGOs, mixed GGOs and solid nodules between radiologists and technologists were not statistically significant, except for the case of solid nodules; the p-values of the differences for pure GGOs, mixed GGOs and solid nodules on the CT images with 5-mm slice thickness were 0.095, 0.461 and 0.005, respectively, and the corresponding p-values on CT images of 2-mm slice thickness were 0.971, 0.722 and 0.0037, respectively. Conclusion Well-trained technologists may contribute to the detection of pure and mixed GGOs ≥5 mm in diameter on low-dose screening CT images. PMID:22919013

  12. Validity of an interviewer-administered patient health questionnaire-9 to screen for depression in HIV-infected patients in Cameroon.

    PubMed

    Pence, Brian W; Gaynes, Bradley N; Atashili, Julius; O'Donnell, Julie K; Tayong, Gladys; Kats, Dmitry; Whetten, Rachel; Whetten, Kathryn; Njamnshi, Alfred K; Ndumbe, Peter M

    2012-12-20

    In high-income countries, depression is prevalent in HIV patients and is associated with lower medication adherence and clinical outcomes. Emerging evidence from low-income countries supports similar relationships. Yet little research has validated rapid depression screening tools integrated into routine HIV clinical care. Using qualitative methods, we adapted the Patient Health Questionnaire-9 (PHQ-9) depression screening instrument for use with Cameroonian patients. We then conducted a cross-sectional validity study comparing an interviewer-administered PHQ-9 to the reference standard Composite International Diagnostic Interview in 400 patients on antiretroviral therapy attending a regional HIV treatment center in Bamenda, Cameroon. The prevalence of major depressive disorder (MDD) in the past month was 3% (n=11 cases). Using a standard cutoff score of ≥10 as a positive depression screen, the PHQ-9 had estimated sensitivity of 27% (95% confidence interval: 6-61%) and specificity of 94% (91-96%), corresponding to positive and negative likelihood ratios of 4.5 and 0.8. There was little evidence of variation in specificity by gender, number of HIV symptoms, or result of a dementia screen. The low prevalence of MDD yielded very imprecise sensitivity estimates. Although the PHQ-9 was developed as a self-administered tool, we assessed an interviewer-administered version due to the literacy level of the target population. The PHQ-9 demonstrated high specificity but apparently low sensitivity for detecting MDD in this sample of HIV patients in Cameroon. Formative work to define the performance of proven screening tools in new settings remains important as research on mental health expands in low-income countries. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Primary screening for cervical cancer based on high-risk human papillomavirus (HPV) detection and HPV 16 and HPV 18 genotyping, in comparison to cytology.

    PubMed

    Agorastos, Theodoros; Chatzistamatiou, Kimon; Katsamagkas, Taxiarchis; Koliopoulos, George; Daponte, Alexandros; Constantinidis, Theocharis; Constantinidis, Theodoros C

    2015-01-01

    The objective of the present study is to assess the performance of a high-risk human papillomavirus (HR-HPV) DNA test with individual HPV-16/HPV-18 genotyping as a method for primary cervical cancer screening compared with liquid-based cytology (LBC) in a population of Greek women taking part in routine cervical cancer screening. The study, conducted by the "HEllenic Real life Multicentric cErvical Screening" (HERMES) study group, involved the recruitment of 4,009 women, aged 25-55, who took part in routine cervical screening at nine Gynecology Departments in Greece. At first visit cervical specimens were collected for LBC and HPV testing using the Roche Cobas 4800 system. Women found positive for either cytology or HPV were referred for colposcopy, whereas women negative for both tests will be retested after three years. The study is ongoing and the results of the first screening round are reported herein. Valid results for cytology and HPV testing were obtained for 3,993 women. The overall prevalence of HR-HPV was 12.7%, of HPV-16 2.7% and of HPV-18 1.4%. Of those referred for colposcopy, cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was detected in 41 women (1.07%). At the threshold of CIN2+, cytology [atypical squamous cells of undetermined significance (ASC-US) or worse] and HPV testing showed a sensitivity of 53.7% and 100% respectively, without change between age groups. Cytology and HPV testing showed specificity of 96.8% and 90.3% respectively, which was increased in older women (≥30) in comparison to younger ones (25-29). Genotyping for HPV16/18 had similar accuracy to cytology for the detection of CIN2+ (sensitivity: 58.5%; specificity 97.5%) as well as for triage to colposcopy (sensitivity: 58.5% vs 53.7% for cytology). HPV testing has much better sensitivity than cytology to identify high-grade cervical lesions with slightly lower specificity. HPV testing with individual HPV-16/HPV-18 genotyping could represent a more accurate methodology for primary cervical cancer screening in comparison to liquid-based cytology, especially in older women.

  14. Rectal swab sampling followed by an enrichment culture-based real-time PCR assay to detect Salmonella enterocolitis in children.

    PubMed

    Lin, L-H; Tsai, C-Y; Hung, M-H; Fang, Y-T; Ling, Q-D

    2011-09-01

    Although routine bacterial culture is the traditional reference standard method for the detection of Salmonella infection in children with diarrhoea, it is a time-consuming procedure that usually only gives results after 3-4 days. Some molecular detection methods can improve the turn-around time to within 24 h, but these methods are not applied directly from stool or rectal swab specimens as routine diagnostic methods for the detection of gastrointestinal pathogens. In this study, we tested the feasibility of a bacterial enrichment culture-based real-time PCR assay method for detecting and screening for diarrhoea in children caused by Salmonella. Our results showed that the minimum real-time PCR assay time required to detect enriched bacterial culture from a swab was 3 h. In all children with suspected Salmonella diarrhoea, the enrichment culture-based real-time PCR achieved 85.4% sensitivity and 98.1% specificity, as compared with the 53.7% sensitivity and 100% specificity of detection with the routine bacterial culture method. We suggest that rectal swab sampling followed by enrichment culture-based real-time PCR is suitable as a rapid method for detecting and screening for Salmonella in paediatric patients. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  15. Rapid screening for inflammatory neuropathies by standardized clinical criteria

    PubMed Central

    Tramontozzi, Louis A.

    2016-01-01

    Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273

  16. [Psychometric properties and diagnostic value of 'lexical screening for aphasias'].

    PubMed

    Pena-Chavez, R; Martinez-Jimenez, L; Lopez-Espinoza, M

    2014-09-16

    INTRODUCTION. Language assessment in persons with brain injury makes it possible to know whether they require language rehabilitation or not. Given the importance of a precise evaluation, assessment instruments must be valid and reliable, so as to avoid mistaken and subjective diagnoses. AIM. To validate 'lexical screening for aphasias' in a sample of 58 Chilean individuals. SUBJECTS AND METHODS. A screening-type language test, lasting 20 minutes and based on the lexical processing model devised by Patterson and Shewell (1987), was constructed. The sample was made up of two groups containing 29 aphasic subjects and 29 control subjects from different health centres in the regions of Biobio and Maule, Chile. Their ages ranged between 24 and 79 years and had between 0 and 17 years' schooling. Tests were carried out to determine discriminating validity, concurrent validity with the aphasia disorder assessment battery, reliability, sensitivity and specificity. RESULTS. The statistical analysis showed a high discriminating validity (p < 0.001), an acceptable mean concurrent validity with aphasia disorder assessment battery (rs = 0.65), high mean reliability (alpha = 0.87), moderate mean sensitivity (69%) and high mean specificity (86%). CONCLUSION. 'Lexical screening for aphasias' is valid and reliable for assessing language in persons with aphasias; it is sensitive for detecting aphasic subjects and is specific for precluding language disorders in persons with normal language abilities.

  17. A new versatile microarray-based method for high throughput screening of carbohydrate-active enzymes.

    PubMed

    Vidal-Melgosa, Silvia; Pedersen, Henriette L; Schückel, Julia; Arnal, Grégory; Dumon, Claire; Amby, Daniel B; Monrad, Rune Nygaard; Westereng, Bjørge; Willats, William G T

    2015-04-03

    Carbohydrate-active enzymes have multiple biological roles and industrial applications. Advances in genome and transcriptome sequencing together with associated bioinformatics tools have identified vast numbers of putative carbohydrate-degrading and -modifying enzymes including glycoside hydrolases and lytic polysaccharide monooxygenases. However, there is a paucity of methods for rapidly screening the activities of these enzymes. By combining the multiplexing capacity of carbohydrate microarrays with the specificity of molecular probes, we have developed a sensitive, high throughput, and versatile semiquantitative enzyme screening technique that requires low amounts of enzyme and substrate. The method can be used to assess the activities of single enzymes, enzyme mixtures, and crude culture broths against single substrates, substrate mixtures, and biomass samples. Moreover, we show that the technique can be used to analyze both endo-acting and exo-acting glycoside hydrolases, polysaccharide lyases, carbohydrate esterases, and lytic polysaccharide monooxygenases. We demonstrate the potential of the technique by identifying the substrate specificities of purified uncharacterized enzymes and by screening enzyme activities from fungal culture broths. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  18. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    PubMed

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  19. Evaluation of a recombinant yeast cell estrogen screening assay.

    PubMed Central

    Coldham, N G; Dave, M; Sivapathasundaram, S; McDonnell, D P; Connor, C; Sauer, M J

    1997-01-01

    A wide range of chemicals with diverse structures derived from plant and environmental origins are reported to have hormonal activity. The potential for appreciable exposure of humans to such substances prompts the need to develop sensitive screening methods to quantitate and evaluate the risk to the public. Yeast cells transformed with plasmids encoding the human estrogen receptor and an estrogen responsive promoter linked to a reporter gene were evaluated for screening compounds for estrogenic activity. Relative sensitivity to estrogens was evaluated by reference to 17 beta-estradiol (E2) calibration curves derived using the recombinant yeast cells, MCF-7 human breast cancer cells, and a prepubertal mouse uterotrophic bioassay. The recombinant yeast cell bioassay (RCBA) was approximately two and five orders of magnitude more sensitive to E2 than MCF-7 cells and the uterotrophic assay, respectively. The estrogenic potency of 53 chemicals, including steroid hormones, synthetic estrogens, environmental pollutants, and phytoestrogens, was measured using the RCBA. Potency values produced with the RCBA relative to E2 (100) included estrone (9.6), diethylstilbestrol (74.3), tamoxifen (0.0047), alpha-zearalanol (1.3), equol (0.085), 4-nonylphenol (0.005), and butylbenzyl phathalate (0.0004), which were similar to literature values but generally higher than those produced by the uterotrophic assay. Exquisite sensitivity, absence of test compound biotransformation, ease of use, and the possibility of measuring antiestrogenic activity are important attributes that argue for the suitability of the RCBA in screening for potential xenoestrogens to evaluate risk to humans, wildlife, and the environment. Images Figure 1. Figure 2. Figure 3. Figure 4. PMID:9294720

  20. Method for detecting the reactivity of chemicals towards peptides as an alternative test method for assessing skin sensitization potential.

    PubMed

    Cho, Sun-A; Jeong, Yun Hyeok; Kim, Ji Hoon; Kim, Seoyoung; Cho, Jun-Cheol; Heo, Yong; Heo, Young; Suh, Kyung-Do; Shin, Kyeho; An, Susun

    2014-02-10

    Cosmetics are normally composed of various ingredients. Some cosmetic ingredients can act as chemical haptens reacting toward proteins or peptides of human skin and they can provoke an immunologic reaction, called as skin sensitization. This haptenation process is very important step of inducing skin sensitization and evaluating the sensitizing potentials of cosmetic ingredients is very important for consumer safety. Therefore, animal alternative methods focusing on monitoring haptenation potential are undergoing vigorous research. To examine the further usefulness of spectrophotometric methods to monitor reactivity of chemicals toward peptides for cosmetic ingredients. Forty chemicals (25 sensitizers and 15 non-sensitizers) were reacted with 2 synthetic peptides, e.g., the cysteine peptides (Ac-RFAACAA-COOH) with free thiol group and the lysine peptides (Ac-RFAAKAA-COOH) with free amine group. Unreacted peptides can be detected after incubating with 5,5'-dithiobis-2-nitrobenzoic acid or fluorescamine™ as detection reagents for free thiol and amine group, respectively. Chemicals were categorized as sensitizers when they induced more than 10% depletion of cysteine peptides or more than 30% depletion of lysine peptides. The sensitivity, specificity, and accuracy were 80.0%, 86.7% and 82.5%, respectively. These results demonstrate that spectrophotometric methods can be an easy, fast, and high-throughput screening tools predicting the skin sensitization potential of chemical including cosmetic ingredient. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    PubMed

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.

  2. High performance of a new PCR-based urine assay for HPV-DNA detection and genotyping.

    PubMed

    Tanzi, Elisabetta; Bianchi, Silvia; Fasolo, Maria Michela; Frati, Elena R; Mazza, Francesca; Martinelli, Marianna; Colzani, Daniela; Beretta, Rosangela; Zappa, Alessandra; Orlando, Giovanna

    2013-01-01

    Human papillomavirus (HPV) testing has been proposed as a means of replacing or supporting conventional cervical screening (Pap test). However, both methods require the collection of cervical samples. Urine sample is easier and more acceptable to collect and could be helpful in facilitating cervical cancer screening. The aim of this study was to evaluate the sensitivity and specificity of urine testing compared to conventional cervical smear testing using a PCR-based method with a new, designed specifically primer set. Paired cervical and first voided urine samples collected from 107 women infected with HIV were subjected to HPV-DNA detection and genotyping using a PCR-based assay and a restriction fragment length polymorphism method. Sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) were calculated using the McNemar's test for differences. Concordance between tests was assessed using the Cohen's unweighted Kappa (k). HPV DNA was detected in 64.5% (95% CI: 55.1-73.1%) of both cytobrush and urine samples. High concordance rates of HPV-DNA detection (k = 0.96; 95% CI: 0.90-1.0) and of high risk-clade and low-risk genotyping in paired samples (k = 0.80; 95% CI: 0.67-0.92 and k = 0.74; 95% CI: 0.60-0.88, respectively) were observed. HPV-DNA detection in urine versus cervix testing revealed a sensitivity of 98.6% (95% CI: 93.1-99.9%) and a specificity of 97.4% (95% CI: 87.7-99.9%), with a very high NPV (97.4%; 95% CI: 87.7-99.9%). The PCR-based assay utilized in this study proved highly sensitive and specific for HPV-DNA detection and genotyping in urine samples. These data suggest that a urine-based assay would be a suitable and effective tool for epidemiological surveillance and, most of all, screening programs. Copyright © 2012 Wiley Periodicals, Inc.

  3. Usefulness of Chest Radiographs for Scoliosis Screening: A Comparison with Thoraco-Lumbar Standing Radiographs

    PubMed Central

    Oh, Chang Hyun; Kim, Chan Gyu; Lee, Myoung Seok; Park, Hyeong-Chun; Park, Chong Oon

    2012-01-01

    Purpose The purposes of this study were to evaluate the usefulness and limitations of chest radiographs in scoliosis screening and to compare these results with those of thoraco-lumbar standing radiographs (TLSR). Materials and Methods During Korean conscription, 419 males were retrospectively examined using both chest radiographs and TLSR to confirm the scoliosis and Cobb angle at the Regional Military Manpower. We compared the types of spinal curves and Cobb angles as measured from different radiographs. Results In the pattern of spinal curves, the overall matching rate of chest radiographs using TLSR was about 58.2% (244 of 419 cases). Cobb angle differences between chest radiographs and TLSR with meaningful difference was observed in 156 cases (37.2%); a relatively high proportion (9.5%) of Cobb angle differences more than 10 degrees was also observed. The matching rate of both spinal curve types and Cobb angle accuracy between chest radiographs and TLSR was 27.9% (117 among 419 cases). Chest radiographs for scoliosis screening were observed with 93.94% of sensitivity and 61.67% of specificity in thoracic curves; however, less than 40% of sensitivity (38.27%, 20.00%, and 25.80%) and more than 95% of specificity (97.34%, 99.69%, and 98.45%) were observed in thoraco-lumbar, lumbar, and double major curves, respectively. Conclusion The accuracy of chest radiographs for scoliosis screening was low. The incidence of thoracic curve scoliosis was overestimated and lumbar curve scoliosis was easily missed by chest radiography. Scoliosis screening using chest radiography has limited values, nevertheless, it is useful method for detecting thoracic curve scoliosis. PMID:23074120

  4. Improved agar diffusion method for detecting residual antimicrobial agents.

    PubMed

    Tsai, C E; Kondo, F

    2001-03-01

    The improved agar diffusion method for determination of residual antimicrobial agents was investigated, and the sensitivities of various combinations of test organisms and assay media were determined using 7 organisms, 5 media, and 31 antimicrobial agents. Bacillus stearothermophilus and synthetic assay medium (SAM) showed the greatest sensitivity for screening penicillins (penicillin G and ampicillin). The combination of Bacillus subtilis and minimum medium (MM) was the most sensitive for tetracyclines (oxytetracycline and chlortetracycline), B. stearothermophilus and SAM or Micrococcus luteus and Mueller-Hinton agar (MHA) for detecting tylosin and erythromycin, B. subtilis and MHA for aminoglycosides (streptomycin, kanamycin, gentamicin, and dihydrostreptomycin), B. stearothermophilus and SAM for polyethers (salinomycin and lasalocid), and B. subtilis and MM or Clostridium perfringens and GAM for polypeptides (thiopeptin, enramycin, virginiamycin, and bacitracin). However, gram-negative bacterium Escherichia coli ATCC 27166 and MM were better for screening for colistin and polymixin-B. For detecting the synthetic drugs tested, the best combination was B. subtilis and MM for sulfonamides, E. coli 27166 and MM for quinolones (oxolinic acid and nalidixic acid), B. subtilis and MM for furans (furazolidone), and the bioluminescent bacterium Photobacterium phosphoreum and luminescence assay medium for chloramphenicol and oxolinic acid. The results showed that the use of four assay plates, B. stearothermophilus and SAM, B. subtilis and MM, M. luteus and MHA, and E. coli 27166 and MM, was superior to the currently available techniques for screening for residual antimicrobial agents in edible animal tissues.

  5. Indirect electrochemical detection for total bile acids in human serum.

    PubMed

    Zhang, Xiaoqing; Zhu, Mingsong; Xu, Biao; Cui, Yue; Tian, Gang; Shi, Zhenghu; Ding, Min

    2016-11-15

    Bile acids level in serum is a useful index for screening and diagnosis of hepatobiliary diseases. As bile acids concentration is closely related to the degree of hepatobiliary diseases, detecting it is a vital factor to understand the stage of the diseases. The prevalent determination for bile acids is the enzymatic cycling method which has low sensitivity while reagent-consuming. It is desirable to develop a new method with lower cost and higher sensitivity. An indirect electrochemical detection (IED) for bile acids in human serum was established using the screen printed carbon electrode (SPCE). Since bile acids do not show electrochemical signals, they were converted to 3-ketosteroids by 3-α-hydroxysteroid dehydrogenase (3α-HSD) in the presence of nicotinamide adenine dinucleotide (NAD(+)), which was reduced to NADH. NADH could then be oxidized on the surface of SPCE, generating a signal that was used to calculate the total bile acids (TBA) concentration. A good linear calibration for TBA was obtained at the concentration range from 5.00μM to 400μM in human serum. Both the precisions and recoveries were sufficient to be used in a clinical setting. The TBA concentrations in 35 human serum samples by our IED method didn't show significant difference with the result by enzymatic cycling method, using the paired t-test. Moreover, our IED method is reagent-saving, sensitive and cost-effective. Copyright © 2016. Published by Elsevier B.V.

  6. Rapid Screening Method for New Psychoactive Substances of Forensic Interest: Electrochemistry and Analytical Determination of Phenethylamines Derivatives (NBOMe) via Cyclic and Differential Pulse Voltammetry.

    PubMed

    Andrade, Ana Flávia B; Mamo, Samuel Kasahun; Gonzalez-Rodriguez, Jose

    2017-02-07

    The NBOMe derivatives are phenethylamines derived from the 2C class of hallucinogens. Only a few human pharmacologic studies have been conducted on these drugs, and several cases of intoxication and deaths have been reported. Presently, NBOMe are not a part of the routine drugs-of-abuse screening procedure for many police forces, and there are no rapid immunoassay screening tests that can detect the presence of those compounds. In this Article, the voltammetric behavior of 25B NBOMe and 25I NBOMe were investigated and their electroanalytical characteristics determined for the first time. A novel, fast, and sensitive screening method for the identification of the two most common NBOMes (25B-NBOMe and 25I-NBOMe) in real samples is reported. The method uses the electrochemical oxidation of these molecules to produce an analytical signal that can be related to the NBOMe concentration with an average lower limit of quantitation of 0.01 mg/mL for both of them. The method is selective enough to identify the two compounds individually, even given the great similarity in their structure.

  7. Aptamer-mediated colorimetric method for rapid and sensitive detection of chloramphenicol in food.

    PubMed

    Yan, Chao; Zhang, Jing; Yao, Li; Xue, Feng; Lu, Jianfeng; Li, Baoguang; Chen, Wei

    2018-09-15

    We report an aptamer-mediated colorimetric method for sensitive detection of chloramphenicol (CAP). The aptamer of CAP is immobilized by the hybridization with pre-immobilized capture probe in the microtiter plate. The horseradish peroxidase (HRP) is covalently attached to the aptamer by the biotin-streptavidin system for signal production. CAP will preferably bind with aptamer due to the high binding affinity, which attributes to the release of aptamer and HRP and thus, affects the optical signal intensity. Quantitative determination of CAP is successfully achieved in the wide range from 0.001 to 1000 ng/mL with detection limit of 0.0031 ng/mL, which is more sensitive than traditional immunoassays. This method is further validated by measuring the recovery of CAP spiked in two different food matrices (honey and fish). The aptamer-mediated colorimetric method can be a useful protocol for rapid and sensitive screening of CAP, and may be used as an alternative means for traditional immunoassays. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Rapid and sensitive detection of human astrovirus in water samples by loop-mediated isothermal amplification with hydroxynaphthol blue dye.

    PubMed

    Yang, Bo-Yun; Liu, Xiao-Lu; Wei, Yu-Mei; Wang, Jing-Qi; He, Xiao-Qing; Jin, Yi; Wang, Zi-Jian

    2014-02-14

    The aim of this paper was to develop a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for rapid, sensitive and inexpensive detection of astrovirus. The detection limit of LAMP using in vitro RNA transcripts was 3.6 × 10 copies·μL⁻¹, which is as sensitive as the presently used PCR assays. However, the LAMP products could be identified as different colors with the naked eye following staining with hydroxynaphthol blue dye (HNB). No cross-reactivity with other gastroenteric viruses (rotavirus and norovirus) was observed, indicating the relatively high specificity of LAMP. The RT-LAMP method with HNB was used to effectively detect astrovirus in reclaimed water samples. The LAMP technique described in this study is a cheap, sensitive, specific and rapid method for the detection of astrovirus. The RT-LAMP method can be simply applied for the specific detection of astrovirus and has the potential to be utilized in the field as a screening test.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Sennett, Charlene A.; Giger, Maryellen L.

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patientsmore » (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.« less

  10. Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Sennett, Charlene A.; Giger, Maryellen L.

    2014-01-15

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patientsmore » (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.« less

  11. A method for screening climate change-sensitive infectious diseases.

    PubMed

    Wang, Yunjing; Rao, Yuhan; Wu, Xiaoxu; Zhao, Hainan; Chen, Jin

    2015-01-14

    Climate change is a significant and emerging threat to human health, especially where infectious diseases are involved. Because of the complex interactions between climate variables and infectious disease components (i.e., pathogen, host and transmission environment), systematically and quantitatively screening for infectious diseases that are sensitive to climate change is still a challenge. To address this challenge, we propose a new statistical indicator, Relative Sensitivity, to identify the difference between the sensitivity of the infectious disease to climate variables for two different climate statuses (i.e., historical climate and present climate) in non-exposure and exposure groups. The case study in Anhui Province, China has demonstrated the effectiveness of this Relative Sensitivity indicator. The application results indicate significant sensitivity of many epidemic infectious diseases to climate change in the form of changing climatic variables, such as temperature, precipitation and absolute humidity. As novel evidence, this research shows that absolute humidity has a critical influence on many observed infectious diseases in Anhui Province, including dysentery, hand, foot and mouth disease, hepatitis A, hemorrhagic fever, typhoid fever, malaria, meningitis, influenza and schistosomiasis. Moreover, some infectious diseases are more sensitive to climate change in rural areas than in urban areas. This insight provides guidance for future health inputs that consider spatial variability in response to climate change.

  12. A Method for Screening Climate Change-Sensitive Infectious Diseases

    PubMed Central

    Wang, Yunjing; Rao, Yuhan; Wu, Xiaoxu; Zhao, Hainan; Chen, Jin

    2015-01-01

    Climate change is a significant and emerging threat to human health, especially where infectious diseases are involved. Because of the complex interactions between climate variables and infectious disease components (i.e., pathogen, host and transmission environment), systematically and quantitatively screening for infectious diseases that are sensitive to climate change is still a challenge. To address this challenge, we propose a new statistical indicator, Relative Sensitivity, to identify the difference between the sensitivity of the infectious disease to climate variables for two different climate statuses (i.e., historical climate and present climate) in non-exposure and exposure groups. The case study in Anhui Province, China has demonstrated the effectiveness of this Relative Sensitivity indicator. The application results indicate significant sensitivity of many epidemic infectious diseases to climate change in the form of changing climatic variables, such as temperature, precipitation and absolute humidity. As novel evidence, this research shows that absolute humidity has a critical influence on many observed infectious diseases in Anhui Province, including dysentery, hand, foot and mouth disease, hepatitis A, hemorrhagic fever, typhoid fever, malaria, meningitis, influenza and schistosomiasis. Moreover, some infectious diseases are more sensitive to climate change in rural areas than in urban areas. This insight provides guidance for future health inputs that consider spatial variability in response to climate change. PMID:25594780

  13. A combined strategy for screening a clustered mobile population returning from highly endemic areas for Plasmodium falciparum.

    PubMed

    Li, Mei; Li, Jun; Xia, Zhigui; Xiao, Ning; Jiang, Weikang; Wen, Yongkang

    2017-04-30

    Early and accurate diagnosis of imported malaria cases in clusters is crucial for protecting the health of patients and local populations, especially confirmed parasitic persons who are asymptomatic. A total of 226 gold miners who had stayed in highly endemic areas of Ghana for more than six months and returned in clusters were selected randomly. Blood samples from them were tested with microscopy, nest polymerase chain reaction, and rapid diagnostic test (RDT). The sensitivity, specificity, predictive values, agreement rate, and Youden's index of each of three diagnostic methods were calculated and compared with the defined gold standard. A quick and efficient way to respond to screening such a clustered mobile population was predicted and analyzed by evaluating two assumed results of combining microscopy and RDT with or without symptoms of illness. The rate of the carriers of malaria parasites in the populations of gold miners was 19.47%, including 39 P. falciparum. Among the three diagnostic methods, the microscopy method showed the highest specificity, while the RDT method showed the highest sensitivity but the lowest specificity in detecting P. falciparum. The assumed results of combining RDT and microscopy with symptoms showed the best results among all the test results in screening P. falciparum. It was too complex and difficult to catch all parasite carriers in a short period of time among populations with such a complicated situation as that in Shanglin County. A strategy of combing microscopy and RDT for diagnosis is highly recommended.

  14. Screening and prevention of neonatal glucose 6-phosphate dehydrogenase deficiency in Guangzhou, China.

    PubMed

    Jiang, J; Li, B; Cao, W; Jiang, X; Jia, X; Chen, Q; Wu, J

    2014-06-09

    We aimed to summarize the results of screening protocol and prevention of neonatal glucose 6-phosphate dehydrogenase (G6PD) deficiency during a 22-year-long period to provide a basis of reference for the screening of this disease. About 1,705,569 newborn subjects in Guangzhou City were screened for this deficiency. Specimens were collected according to the conventional method of specimen acquisition for "newborn dried bloodspot screening", preserved, and inspected. The specimens were studied with fluorescent spot test and quantitative fluorescence assay. Diagnosis was performed using the modified NBTG6PD/6PGD ratio method. Bloodspot filter paper specimens were sent to the laboratory within 24 h via EMS Express, and the G6PD test was performed on the same day. The G6PD deficiency-positive rate was 4.2% in the samples screened using the fluorescent spot test, while it was 5% in case of the quantitative fluorescence assay. Neonatal screening for G6PD deficiency for 11,437 cases (6117 boys and 5320 girls) showed positive results in 481 cases. About 420 cases (318 boys and 102 girls) of G6PD deficiency were confirmed with the modified Duchenne NBT ratio method. The total detection rate was 3.7:5.2% for boys and 1.9% for girls. Quantitative fluorescence assay improved the sensitivity and detection rate. Accelerating the speed of sample delivery by using Internet network systems and ensuring online availability of screening results can aid the screening and diagnosis of this deficiency within 1 week of birth.

  15. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    PubMed Central

    Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L

    2007-01-01

    Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958

  16. Towards early detection of cervical cancer: Fractal dimension of AFM images of human cervical epithelial cells at different stages of progression to cancer.

    PubMed

    Guz, Nataliia V; Dokukin, Maxim E; Woodworth, Craig D; Cardin, Andrew; Sokolov, Igor

    2015-10-01

    We used AFM HarmoniX modality to analyse the surface of individual human cervical epithelial cells at three stages of progression to cancer, normal, immortal (pre-malignant) and carcinoma cells. Primary cells from 6 normal strains, 6 cancer, and 6 immortalized lines (derived by plasmid DNA-HPV-16 transfection of cells from 6 healthy individuals) were tested. This cell model allowed for good control of the cell phenotype down to the single cell level, which is impractical to attain in clinical screening tests (ex-vivo). AFM maps of physical (nonspecific) adhesion are collected on fixed dried cells. We show that a surface parameter called fractal dimension can be used to segregate normal from both immortal pre-malignant and malignant cells with sensitivity and specificity of more than 99%. The reported method of analysis can be directly applied to cells collected in liquid cytology screening tests and identified as abnormal with regular optical methods to increase sensitivity. Despite cervical smear screening, sometimes it is very difficult to differentiate cancers cells from pre-malignant cells. By using AFM to analyze the surface properties of human cervical epithelial cells, the authors were able to accurately identify normal from abnormal cells. This method could augment existing protocols to increase diagnostic accuracy. Copyright © 2015. Published by Elsevier Inc.

  17. Development and validation of duplex, triplex, and pentaplex real-time PCR screening assays for the detection of genetically modified organisms in food and feed.

    PubMed

    Huber, Ingrid; Block, Annette; Sebah, Daniela; Debode, Frédéric; Morisset, Dany; Grohmann, Lutz; Berben, Gilbert; Stebih, Dejan; Milavec, Mojca; Zel, Jana; Busch, Ulrich

    2013-10-30

    Worldwide, qualitative methods based on PCR are most commonly used as screening tools for genetically modified material in food and feed. However, the increasing number and diversity of genetically modified organisms (GMO) require effective methods for simultaneously detecting several genetic elements marking the presence of transgenic events. Herein we describe the development and validation of a pentaplex, as well as complementary triplex and duplex real-time PCR assays, for the detection of the most common screening elements found in commercialized GMOs: P-35S, T-nos, ctp2-cp4-epsps, bar, and pat. The use of these screening assays allows the coverage of many GMO events globally approved for commercialization. Each multiplex real-time PCR assay shows high specificity and sensitivity with an absolute limit of detection below 20 copies for the targeted sequences. We demonstrate by intra- and interlaboratory tests that the assays are robust as well as cost- and time-effective for GMO screening if applied in routine GMO analysis.

  18. Predicting the effectiveness of the Finnish population-based colorectal cancer screening programme.

    PubMed

    Chiu, Sherry Yueh-Hsia; Malila, Nea; Yen, Amy Ming-Fang; Chen, Sam Li-Sheng; Fann, Jean Ching-Yuan; Hakama, Matti

    2017-12-01

    Objective Because colorectal cancer (CRC) has a long natural history, estimating the effectiveness of CRC screening programmes requires long-term follow-up. As an alternative, we here demonstrate the use of a temporal multi-state natural history model to predict the effectiveness of CRC screening. Methods In the Finnish population-based biennial CRC screening programme using faecal occult blood tests (FOBT), which was conducted in a randomised health services study, we estimated the pre-clinical incidence, the mean sojourn time (MST), and the sensitivity of FOBT using a Markov model to analyse data from 2004 to 2007. These estimates were applied to predict, through simulation, the effects of five rounds of screening on the relative rate of reducing advanced CRC with 6 years of follow-up, and on the reduction in mortality with 10 years of follow-up, in a cohort of 500,000 subjects aged 60 to 69. Results For localised and non-localised CRC, respectively, the MST was 2.06 and 1.36 years and the sensitivity estimates were 65.12% and 73.70%. The predicted relative risk of non-localised CRC and death from CRC in the screened compared with the control population was 0.86 (95% CI: 0.79-0.98) and 0.91 (95% CI: 0.85-1.02), respectively. Conclusion Based on the preliminary results of the Finnish CRC screening programme, our model predicted a 9% reduction in CRC mortality and a 14% reduction in advanced CRC.

  19. Costs of cervical cancer screening and treatment using visual inspection with acetic acid (VIA) and cryotherapy in Ghana: the importance of scale

    PubMed Central

    Quentin, Wilm; Adu-Sarkodie, Yaw; Terris-Prestholt, Fern; Legood, Rosa; Opoku, Baafuor K; Mayaud, Philippe

    2011-01-01

    Objectives To estimate the incremental costs of visual inspection with acetic acid (VIA) and cryotherapy at cervical cancer screening facilities in Ghana; to explore determinants of costs through modelling; and to estimate national scale-up and annual programme costs. Methods Resource-use data were collected at four out of six active VIA screening centres, and unit costs were ascertained to estimate the costs per woman of VIA and cryotherapy. Modelling and sensitivity analysis were used to explore the influence of observed differences between screening facilities on estimated costs and to calculate national costs. Results Incremental economic costs per woman screened with VIA ranged from 4.93 US$ to 14.75 US$, and costs of cryotherapy were between 47.26 US$ and 84.48 US$ at surveyed facilities. Under base case assumptions, our model estimated the costs of VIA to be 6.12 US$ per woman and those of cryotherapy to be 27.96 US$. Sensitivity analysis showed that the number of women screened per provider and treated per facility was the most important determinants of costs. National annual programme costs were estimated to be between 0.6 and 4.0 million US$ depending on assumed coverage and adopted screening strategy. Conclusion When choosing between different cervical cancer prevention strategies, the feasibility of increasing uptake to achieve economies of scale should be a major concern. PMID:21214692

  20. Clarifying the debate on population-based screening for breast cancer with mammography

    PubMed Central

    Chen, Tony Hsiu-Hsi; Yen, Amy Ming-Fang; Fann, Jean Ching-Yuan; Gordon, Paula; Chen, Sam Li-Sheng; Chiu, Sherry Yueh-Hsia; Hsu, Chen-Yang; Chang, King-Jen; Lee, Won-Chul; Yeoh, Khay Guan; Saito, Hiroshi; Promthet, Supannee; Hamashima, Chisato; Maidin, Alimin; Robinson, Fredie; Zhao, Li-Zhong

    2017-01-01

    Abstract Background: The recent controversy about using mammography to screen for breast cancer based on randomized controlled trials over 3 decades in Western countries has not only eclipsed the paradigm of evidence-based medicine, but also puts health decision-makers in countries where breast cancer screening is still being considered in a dilemma to adopt or abandon such a well-established screening modality. Methods: We reanalyzed the empirical data from the Health Insurance Plan trial in 1963 to the UK age trial in 1991 and their follow-up data published until 2015. We first performed Bayesian conjugated meta-analyses on the heterogeneity of attendance rate, sensitivity, and over-detection and their impacts on advanced stage breast cancer and death from breast cancer across trials using Bayesian Poisson fixed- and random-effect regression model. Bayesian meta-analysis of causal model was then developed to assess a cascade of causal relationships regarding the impact of both attendance and sensitivity on 2 main outcomes. Results: The causes of heterogeneity responsible for the disparities across the trials were clearly manifested in 3 components. The attendance rate ranged from 61.3% to 90.4%. The sensitivity estimates show substantial variation from 57.26% to 87.97% but improved with time from 64% in 1963 to 82% in 1980 when Bayesian conjugated meta-analysis was conducted in chronological order. The percentage of over-detection shows a wide range from 0% to 28%, adjusting for long lead-time. The impacts of the attendance rate and sensitivity on the 2 main outcomes were statistically significant. Causal inference made by linking these causal relationships with emphasis on the heterogeneity of the attendance rate and sensitivity accounted for the variation in the reduction of advanced breast cancer (none-30%) and of mortality (none-31%). We estimated a 33% (95% CI: 24–42%) and 13% (95% CI: 6–20%) breast cancer mortality reduction for the best scenario (90% attendance rate and 95% sensitivity) and the poor scenario (30% attendance rate and 55% sensitivity), respectively. Conclusion: Elucidating the scenarios from high to low performance and learning from the experiences of these trials helps screening policy-makers contemplate on how to avoid errors made in ineffective studies and emulate the effective studies to save women lives. PMID:28099330

  1. Human papillomavirus testing and liquid-based cytology in primary screening of women younger than 35 years: results at recruitment for a randomised controlled trial.

    PubMed

    Ronco, Guglielmo; Giorgi-Rossi, Paolo; Carozzi, Francesca; Dalla Palma, Paolo; Del Mistro, Annarosa; De Marco, Laura; De Lillo, Margherita; Naldoni, Carlo; Pierotti, Paola; Rizzolo, Raffaella; Segnan, Nereo; Schincaglia, Patrizia; Zorzi, Manuel; Confortini, Massimo; Cuzick, Jack

    2006-07-01

    Testing for human papillomavirus (HPV) DNA is more sensitive but less specific than cytological analysis. Loss in specificity is most relevant in women younger than 35 years because of increased HPV prevalence. We aimed to compare conventional screening with an experimental strategy in women aged 25-34 years, and investigate the effect of different criteria of referral to define the best methods of HPV screening. Women were randomly assigned to the conventional procedure (standard cytology, with referral to colposcopy if cytology showed atypical squamous cells of undetermined significance or more [ASCUS+]) or an experimental procedure (liquid-based cytology and testing for high-risk HPV types, with referral to colposcopy with ASCUS+ cytology). Women positive for HPV (cutoff > or = 1 pg/mL) but with normal cytology were retested after 1 year. The main endpoint was the presence of cervical intraepithelial neoplasia at grade 2 or more (CIN2+) in reviewed histology. The main analysis was by intention to screen. This trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN81678807. We randomly assigned 5808 women aged 25-34 years to the conventional group and 6002 to the experimental group. The experimental procedure was significantly more sensitive than the conventional procedure (55 vs 33 CIN2+ lesions detected; relative sensitivity 1.61 [95% CI 1.05-2.48]), but had a lower positive predictive value (PPV; relative PPV 0.55 [0.37-0.82]). HPV testing (> or = 1 pg/mL) with cytology triage was also more sensitive than conventional cytology (relative sensitivity 1.58 [1.03-2.44], relative PPV 0.78 [0.52-1.16]). Relative PPV could be improved, with minimum loss in sensitivity, by use of a 2 pg/mL cutoff for HPV testing. Compared with conventional cytology, liquid-based cytology had a relative sensitivity of 1.32 (0.84-2.06), relative PPV 0.58 [0.38-0.89]). HPV testing alone with cytology triage could be a feasible alternative to conventional cytology for screening women younger than 35 years. Follow-up will provide data on possible overdiagnosis and on the feasibility of extended intervals.

  2. Economic evaluation of DNA ploidy analysis vs liquid-based cytology for cervical screening.

    PubMed

    Nghiem, V T; Davies, K R; Beck, J R; Follen, M; MacAulay, C; Guillaud, M; Cantor, S B

    2015-06-09

    DNA ploidy analysis involves automated quantification of chromosomal aneuploidy, a potential marker of progression toward cervical carcinoma. We evaluated the cost-effectiveness of this method for cervical screening, comparing five ploidy strategies (using different numbers of aneuploid cells as cut points) with liquid-based Papanicolaou smear and no screening. A state-transition Markov model simulated the natural history of HPV infection and possible progression into cervical neoplasia in a cohort of 12-year-old females. The analysis evaluated cost in 2012 US$ and effectiveness in quality-adjusted life-years (QALYs) from a health-system perspective throughout a lifetime horizon in the US setting. We calculated incremental cost-effectiveness ratios (ICERs) to determine the best strategy. The robustness of optimal choices was examined in deterministic and probabilistic sensitivity analyses. In the base-case analysis, the ploidy 4 cell strategy was cost-effective, yielding an increase of 0.032 QALY and an ICER of $18 264/QALY compared to no screening. For most scenarios in the deterministic sensitivity analysis, the ploidy 4 cell strategy was the only cost-effective strategy. Cost-effectiveness acceptability curves showed that this strategy was more likely to be cost-effective than the Papanicolaou smear. Compared to the liquid-based Papanicolaou smear, screening with a DNA ploidy strategy appeared less costly and comparably effective.

  3. Contribution of mammography to MRI screening in BRCA mutation carriers by BRCA status and age: individual patient data meta-analysis.

    PubMed

    Phi, Xuan-Anh; Saadatmand, Sepideh; De Bock, Geertruida H; Warner, Ellen; Sardanelli, Francesco; Leach, Martin O; Riedl, Christopher C; Trop, Isabelle; Hooning, Maartje J; Mandel, Rodica; Santoro, Filippo; Kwan-Lim, Gek; Helbich, Thomas H; Tilanus-Linthorst, Madeleine M A; van den Heuvel, Edwin R; Houssami, Nehmat

    2016-03-15

    We investigated the additional contribution of mammography to screening accuracy in BRCA1/2 mutation carriers screened with MRI at different ages using individual patient data from six high-risk screening trials. Sensitivity and specificity of MRI, mammography and the combination of these tests were compared stratified for BRCA mutation and age using generalised linear mixed models with random effect for studies. Number of screens needed (NSN) for additional mammography-only detected cancer was estimated. In BRCA1/2 mutation carriers of all ages (BRCA1 = 1,219 and BRCA2 = 732), adding mammography to MRI did not significantly increase screening sensitivity (increased by 3.9% in BRCA1 and 12.6% in BRCA2 mutation carriers, P > 0.05). However, in women with BRCA2 mutation younger than 40 years, one-third of breast cancers were detected by mammography only. Number of screens needed for mammography to detect one breast cancer not detected by MRI was much higher for BRCA1 compared with BRCA2 mutation carriers at initial and repeat screening. Additional screening sensitivity from mammography above that from MRI is limited in BRCA1 mutation carriers, whereas mammography contributes to screening sensitivity in BRCA2 mutation carriers, especially those ⩽ 40 years. The evidence from our work highlights that a differential screening schedule by BRCA status is worth considering.

  4. A First Application of Enzyme-Linked Immunosorbent Assay for Screening Cyclodiene Insecticides in Ground Water

    USGS Publications Warehouse

    Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.

  5. Screening for Binge Eating Disorders Using the Patient Health Questionnaire in a Community Sample

    PubMed Central

    Striegel-Moore, Ruth H.; Perrin, Nancy; DeBar, Lynn; Wilson, G. Terence; Rosselli, Francine; Kraemer, Helena C.

    2009-01-01

    Objective To examine the operating characteristics of the Patient Health Questionnaire eating disorder module (PHQ-ED) for identifying bulimia nervosa/binge eating disorder (BN/BED) or recurrent binge eating (RBE) in a community sample, and to compare true positive (TP) versus false positive (FP) cases on clinical validators. Method 259 screen positive individuals and a random sample of 89 screen negative cases completed a diagnostic interview. Sensitivity, specificity, and Positive Predictive Value (PPV) were calculated. TP and FP cases were compared using t-tests and Chi-Square tests. Results The PHQ-ED had high sensitivity (100%) and specificity (92%) for detecting BN/BED or RBE, but PPV was low (15% or 19%). TP and FP cases did not differ significantly on frequency of subjective bulimic episodes, objective overeating, restraint, on BMI, and on self-rated health. Conclusions The PHQ-ED is recommended for use in large populations only in conjunction with follow-up questions to rule out cases without objective bulimic episodes. PMID:19424976

  6. Screening for Cystic Fibrosis-Related Diabetes: Matching Pathophysiology and Addressing Current Challenges.

    PubMed

    Boudreau, Valérie; Reynaud, Quitterie; Dubois, Catherine Lehoux; Coriati, Adèle; Desjardins, Katherine; Durieu, Isabelle; Rabasa-Lhoret, Rémi

    2016-10-01

    Nearly 50% of adult patients with cystic fibrosis (CF) have diabetes. The occurrence of CF-related diabetes (CFRD) is preceded and is associated with deterioration of lung function and nutritional status. Microvascular complications can occur, but the main cause of death is respiratory failure rather than cardiovascular causes as in type 1 or type 2 diabetes. Because other methods such as glycated hemoglobin (A1C) levels are less sensitive in patients with CF, the recommended screening test is the oral glucose tolerance test (OGTT) with a 75 g glucose dose. However, OGTT is poorly suited for patients with CF, who are already facing a high disease-care burden, and appropriate CF-glucose cut-off for diagnosis and prognosis are also questioned. Thus, alternative screening methods are compared to the classical test (2-hour OGTT), including shorter OGTTs and continuous glucose monitoring. Moreover, many challenges complicate the screening for diabetes such as the complex medical care time for a patient, which is reflected by low adherence to screening tests. The best screening test should take into account the particularities of CFRD and the complexity of the CF medical care. Copyright © 2016 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  7. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less

  8. PCR technology for screening and quantification of genetically modified organisms (GMOs).

    PubMed

    Holst-Jensen, Arne; Rønning, Sissel B; Løvseth, Astrid; Berdal, Knut G

    2003-04-01

    Although PCR technology has obvious limitations, the potentially high degree of sensitivity and specificity explains why it has been the first choice of most analytical laboratories interested in detection of genetically modified (GM) organisms (GMOs) and derived materials. Because the products that laboratories receive for analysis are often processed and refined, the quality and quantity of target analyte (e.g. protein or DNA) frequently challenges the sensitivity of any detection method. Among the currently available methods, PCR methods are generally accepted as the most sensitive and reliable methods for detection of GM-derived material in routine applications. The choice of target sequence motif is the single most important factor controlling the specificity of the PCR method. The target sequence is normally a part of the modified gene construct, for example a promoter, a terminator, a gene, or a junction between two of these elements. However, the elements may originate from wildtype organisms, they may be present in more than one GMO, and their copy number may also vary from one GMO to another. They may even be combined in a similar way in more than one GMO. Thus, the choice of method should fit the purpose. Recent developments include event-specific methods, particularly useful for identification and quantification of GM content. Thresholds for labelling are now in place in many countries including those in the European Union. The success of the labelling schemes is dependent upon the efficiency with which GM-derived material can be detected. We will present an overview of currently available PCR methods for screening and quantification of GM-derived DNA, and discuss their applicability and limitations. In addition, we will discuss some of the major challenges related to determination of the limits of detection (LOD) and quantification (LOQ), and to validation of methods.

  9. A novel hypothesis on the sensitivity of the fecal occult blood test: Results of a joint analysis of 3 randomized controlled trials.

    PubMed

    Lansdorp-Vogelaar, Iris; van Ballegooijen, Marjolein; Boer, Rob; Zauber, Ann; Habbema, J Dik F

    2009-06-01

    Estimates of the fecal occult blood test (FOBT) (Hemoccult II) sensitivity differed widely between screening trials and led to divergent conclusions on the effects of FOBT screening. We used microsimulation modeling to estimate a preclinical colorectal cancer (CRC) duration and sensitivity for unrehydrated FOBT from the data of 3 randomized controlled trials of Minnesota, Nottingham, and Funen. In addition to 2 usual hypotheses on the sensitivity of FOBT, we tested a novel hypothesis where sensitivity is linked to the stage of clinical diagnosis in the situation without screening. We used the MISCAN-Colon microsimulation model to estimate sensitivity and duration, accounting for differences between the trials in demography, background incidence, and trial design. We tested 3 hypotheses for FOBT sensitivity: sensitivity is the same for all preclinical CRC stages, sensitivity increases with each stage, and sensitivity is higher for the stage in which the cancer would have been diagnosed in the absence of screening than for earlier stages. Goodness-of-fit was evaluated by comparing expected and observed rates of screen-detected and interval CRC. The hypothesis with a higher sensitivity in the stage of clinical diagnosis gave the best fit. Under this hypothesis, sensitivity of FOBT was 51% in the stage of clinical diagnosis and 19% in earlier stages. The average duration of preclinical CRC was estimated at 6.7 years. Our analysis corroborated a long duration of preclinical CRC, with FOBT most sensitive in the stage of clinical diagnosis. (c) 2009 American Cancer Society.

  10. Use and imaging performance of CMOS flat panel imager with LiF/ZnS(Ag) and Gadox scintillation screens for neutron radiography

    NASA Astrophysics Data System (ADS)

    Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2011-01-01

    In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.

  11. Neonatal screening for glucose-6-phosphate dehydrogenase deficiency fails to detect heterozygote females.

    PubMed

    Zaffanello, Marco; Rugolotto, Simone; Zamboni, Giorgio; Gaudino, Rossella; Tatò, Luciano

    2004-01-01

    We examined glucose-6-phosphate dehydrogenase (G6PD) deficiency in north-eastern Italian Caucasian neonates detected by neonatal screening, in order to measure the incidence of heterozygote females detected by neonatal screening, and to estimate the near-true total incidence. A total of 85,437 Caucasian neonates, born between January 2000 and December 2001, have been enclosed in the study. The total incidence of the disease, measured by fluorescent method, is 0.9 per thousand; the total incidence, calculated by Hardy-Weinberg law, is 4.8 per thousand. The frequency of missed females is 93% of total females expected with G6PD deficiency; most of them are very likely heterozygous females. The sensitivity of the fluorescent method might be not sufficient to detect all females. Since heterozygote females might develop the symptoms of G6PD deficiency later, these results suggest that the G6PD neonatal screening may not be helpful in preventing disease in females.

  12. Validation of an UHPLC-MS/MS Method for Screening of Antimicrobial Residues in Eggs and Their Application to Analyses of Eggs from Laying Hens Subjected to Pharmacological Treatment

    PubMed Central

    Caldeira, Letícia Gomes Magnago; Santos, Flávio Alves; de Oliveira, Andréa Melo Garcia; Lima, Josefa Abucater; de Souza, Leonardo Francisco; da Silva, Guilherme Resende; de Assis, Débora Cristina Sampaio

    2017-01-01

    A multiresidue method by UHPLC/MS-MS was optimized and validated for the screening and semiquantitative detection of antimicrobials residues from tetracyclines, aminoglycosides, quinolones, lincosamides, β-lactams, sulfonamides, and macrolides families in eggs. A qualitative approach was used to ensure adequate sensitivity to detect residues at the level of interest, defined as maximum residue limit (MRL), or less. The applicability of the methods was assessed by analyzing egg samples from hens that had been subjected to pharmacological treatment with neomycin, enrofloxacin, lincomycin, oxytetracycline, and doxycycline during five days and after discontinuation of medication (10 days). The method was adequate for screening all studied analytes in eggs, since the performance parameters ensured a false-compliant rate below or equal to 5%, except for flumequine. In the analyses of eggs from laying hens subjected to pharmacological treatment, all antimicrobial residues were detected throughout the experimental period, even after discontinuation of medication, except for neomycin, demonstrating the applicability of the method for analyses of antimicrobial residues in eggs. PMID:29181222

  13. Performance and comparison of self-reported STI symptoms among high-risk populations - MSM, sex workers, persons living with HIV/AIDS - in El Salvador.

    PubMed

    Shah, Neha S; Kim, Evelyn; de Maria Hernández Ayala, Flor; Guardado Escobar, Maria Elena; Nieto, Ana Isabel; Kim, Andrea A; Paz-Bailey, Gabriela

    2014-12-01

    Resource-limited countries have limited laboratory capability and rely on syndromic management to diagnose sexually transmitted infections (STIs). We aimed to estimate the sensitivity, specificity and positive predictive value (PPV) of STI syndromic management when used as a screening method within a study setting. Men who have sex with men (MSM), female sex workers (FSWs) and people living with HIV/AIDS (PLWHA) participated in a behavioural surveillance study. Data were obtained on demographics, sexual behaviours, STI history and service utilisation. Biological specimens were tested for genital inflammatory infections (Neisseria gonorrhoeae [GC], Chlamydia trachomatis [CT], Mycoplasma genitalium [MG], Trichomonas vaginalis [TV]) and genital ulcerative infection (syphilis and Herpes simplex virus-2). There was a high prevalence of Herpes simplex virus-2 (MSM 48.1%, FSW 82.0% and PLWHA 84.4%). Most participants reported no ulcerative symptoms and the majority of men reported no inflammatory symptoms. Sensitivity and PPV were poor for inflammatory infections among PLWHA and MSM. Sensitivity in FSWs for inflammatory infections was 75%. For ulcerative infections, sensitivity was poor, but specificity and PPV were high. Reliance on self-reported symptoms may not be an effective screening strategy for these populations. STI prevention studies should focus on symptom recognition and consider routine screening and referral for high-risk populations. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. A prediction model based on an artificial intelligence system for moderate to severe obstructive sleep apnea.

    PubMed

    Sun, Lei Ming; Chiu, Hung-Wen; Chuang, Chih Yuan; Liu, Li

    2011-09-01

    Obstructive sleep apnea (OSA) is a major concern in modern medicine; however, it is difficult to diagnose. Screening questionnaires such as the Berlin questionnaire, Rome questionnaire, and BASH'IM score are used to identify patients with OSA. However, the sensitivity and specificity of these tools are not satisfactory. We aim to introduce an artificial intelligence method to screen moderate to severe OSA patients (apnea-hypopnea index ≧15). One hundred twenty patients were asked to complete a newly developed questionnaire before undergoing an overnight polysomnography (PSG) study. One hundred ten validated questionnaires were enrolled in this study. Genetic algorithm (GA) was used to build the five best models based on these questionnaires. The same data were analyzed with logistic regression (LR) for comparison. The sensitivity of the GA models varied from 81.8% to 88.0%, with a specificity of 95% to 97%. On the other hand, the sensitivity and specificity of the LR model were 55.6% and 57.9%, respectively. GA provides a good solution to build models for screening moderate to severe OSA patients, who require PSG evaluation and medical intervention. The questionnaire did not require any special biochemistry data and was easily self-administered. The sensitivity and specificity of the GA models are satisfactory and may improve when more patients are recruited.

  15. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching.

    PubMed

    Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W

    2010-04-01

    The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

  16. A marine bacterial adhesion microplate test using the DAPI fluorescent dye: a new method to screen antifouling agents.

    PubMed

    Leroy, C; Delbarre-Ladrat, C; Ghillebaert, F; Rochet, M J; Compère, C; Combes, D

    2007-04-01

    To develop a method to screen antifouling agents against marine bacterial adhesion as a sensitive, rapid and quantitative microplate fluorescent test. Our experimental method is based on a natural biofilm formed by mono-incubation of the marine bacterium Pseudoalteromonas sp. D41 in sterile natural sea water in a 96-well polystyrene microplate. The 4'6-diamidino-2-phenylindole dye was used to quantify adhered bacteria in each well. The total measured fluorescence in the wells was correlated with the amount of bacteria showing a detection limit of one bacterium per 5 microm(2) and quantifying 2 x 10(7) to 2 x 10(8) bacteria adhered per cm(2). The antifouling properties of three commercial surface-active agents and chlorine were tested by this method in the prevention of adhesion and also in the detachment of already adhered bacteria. The marine bacterial adhesion inhibition rate depending on the agent concentration showed a sigmoid shaped dose-response curve. This test is well adapted for a rapid and quantitative first screening of antifouling agents directly in seawater in the early steps of marine biofilm formation. In contrast to the usual screenings of antifouling products which detect a bactericidal activity, this test is more appropriate to screen antifouling agents for bacterial adhesion removal or bacterial adhesion inhibition activities. This screening test focuses on the antifouling properties of the products, especially the initial steps of marine biofilm formation.

  17. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  18. Holographic deep learning for rapid optical screening of anthrax spores

    PubMed Central

    Jo, YoungJu; Park, Sangjin; Jung, JaeHwang; Yoon, Jonghee; Joo, Hosung; Kim, Min-hyeok; Kang, Suk-Jo; Choi, Myung Chul; Lee, Sang Yup; Park, YongKeun

    2017-01-01

    Establishing early warning systems for anthrax attacks is crucial in biodefense. Despite numerous studies for decades, the limited sensitivity of conventional biochemical methods essentially requires preprocessing steps and thus has limitations to be used in realistic settings of biological warfare. We present an optical method for rapid and label-free screening of Bacillus anthracis spores through the synergistic application of holographic microscopy and deep learning. A deep convolutional neural network is designed to classify holographic images of unlabeled living cells. After training, the network outperforms previous techniques in all accuracy measures, achieving single-spore sensitivity and subgenus specificity. The unique “representation learning” capability of deep learning enables direct training from raw images instead of manually extracted features. The method automatically recognizes key biological traits encoded in the images and exploits them as fingerprints. This remarkable learning ability makes the proposed method readily applicable to classifying various single cells in addition to B. anthracis, as demonstrated for the diagnosis of Listeria monocytogenes, without any modification. We believe that our strategy will make holographic microscopy more accessible to medical doctors and biomedical scientists for easy, rapid, and accurate point-of-care diagnosis of pathogens. PMID:28798957

  19. Developing and validating a perinatal depression screening tool in Kenya blending Western criteria with local idioms: A mixed methods study.

    PubMed

    Green, Eric P; Tuli, Hawa; Kwobah, Edith; Menya, D; Chesire, Irene; Schmidt, Christina

    2018-03-01

    Routine screening for perinatal depression is not common in most primary health care settings. The U.S. Preventive Services Task Force only recently updated their recommendation on depression screening to specifically recommend screening during the pre- and postpartum periods. While practitioners in high-income countries can respond to this new recommendation by implementing one of several existing depression screening tools developed in Western contexts, such as the Edinburgh Postnatal Depression Scale (EPDS) or the Patient Health Questionnaire-9 (PHQ-9), these tools lack strong evidence of cross-cultural equivalence, validity for case finding, and precision in measuring response to treatment in developing countries. Thus, there is a critical need to develop and validate new screening tools for perinatal depression that can be used by lay health workers, primary health care personnel, and patients. Working in rural Kenya, we used free listing, card sorting, and item analysis methods to develop a locally-relevant screening tool that blended Western psychiatric concepts with local idioms of distress. We conducted a validation study with a random sample of 193 pregnant women and new mothers to test the diagnostic accuracy of this scale along with the EPDS and PHQ-9. The sensitivity/specificity of the EPDS and PHQ-9 was estimated to be 0.70/0.72 and 0.70/0.73, respectively. This compared to sensitivity/specificity of 0.90/0.90 for a new 9-item locally-developed tool called the Perinatal Depression Screening (PDEPS). Across these three tools, internal consistency reliability ranged from 0.77 to 0.81 and test-retest reliability ranged from 0.57 to 0.67. The prevalence of depression ranges from 5.2% to 6.2% depending on the clinical reference standard. The EPDS and PHQ-9 are valid and reliable screening tools for perinatal depression in rural Western Kenya, the PDEPS may be a more useful alternative. At less than 10%, the prevalence of depression in this region appears to be lower than other published estimates for African and other low-income countries. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. When does mass screening for open neural tube defects in low-risk pregnancies result in cost savings?

    PubMed Central

    Tosi, L L; Detsky, A S; Roye, D P; Morden, M L

    1987-01-01

    Using a decision analysis model, we estimated the savings that might be derived from a mass prenatal screening program aimed at detecting open neural tube defects (NTDs) in low-risk pregnancies. Our baseline analysis showed that screening v. no screening could be expected to save approximately $8 per pregnancy given a cost of $7.50 for the maternal serum alpha-feto-protein (MSAFP) test and a cost of $42,507 for hospital and rehabilitation services for the first 10 years of life for a child with spina bifida. When a more liberal estimate of the costs of caring for such a child was used, the savings with the screening program were more substantial. We performed extensive sensitivity analyses, which showed that the savings were somewhat sensitive to the cost of the MSAFP test and highly sensitive to the specificity (but not the sensitivity) of the test. A screening program for NTDs in low-risk pregnancies may result in substantial savings in direct health care costs if the screening protocol is followed rigorously and efficiently. PMID:2433011

  1. High-Throughput, Motility-Based Sorter for Microswimmers and Gene Discovery Platform

    NASA Astrophysics Data System (ADS)

    Yuan, Jinzhou; Raizen, David; Bau, Haim

    2015-11-01

    Animal motility varies with genotype, disease progression, aging, and environmental conditions. In many studies, it is desirable to carry out high throughput motility-based sorting to isolate rare animals for, among other things, forward genetic screens to identify genetic pathways that regulate phenotypes of interest. Many commonly used screening processes are labor-intensive, lack sensitivity, and require extensive investigator training. Here, we describe a sensitive, high throughput, automated, motility-based method for sorting nematodes. Our method was implemented in a simple microfluidic device capable of sorting many thousands of animals per hour per module, and is amenable to parallelism. The device successfully enriched for known C. elegans motility mutants. Furthermore, using this device, we isolated low-abundance mutants capable of suppressing the somnogenic effects of the flp-13 gene, which regulates sleep-like quiescence in C. elegans. Subsequent genomic sequencing led to the identification of a flp-13-suppressor gene. This research was supported, in part, by NIH NIA Grant 5R03AG042690-02.

  2. Clinician Suspicion of an Alcohol Problem: An Observational Study From the AAFP National Research Network

    PubMed Central

    Vinson, Daniel C.; Turner, Barbara J.; MSED; Manning, Brian K.; Galliher, James M.

    2013-01-01

    PURPOSE In clinical practice, detection of alcohol problems often relies on clinician suspicion instead of using a screening instrument. We assessed the sensitivity, specificity, and predictive values of clinician suspicion compared with screening-detected alcohol problems in patients. METHODS We undertook a cross-sectional study of 94 primary care clinicians’ office visits. Brief questionnaires were completed separately after a visit by both clinicians and eligible patients. The patient’s anonymous exit questionnaire screened for hazardous drinking based on the Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) and for harmful drinking (alcohol abuse or dependence) based on 2 questions from the Diagnostic and Statistical Manual of Mental Disorders. After the visit, clinicians responded to the question, “Does this patient have problems with alcohol?” with answer options including “yes, hazardous drinking” and “yes, alcohol abuse or dependence.” Analyses assessed the associations between patients’ responses to screening questions and clinician’s suspicions. RESULTS Of 2,518 patients with an office visit, 2,173 were eligible, and 1,699 (78%) completed the exit questionnaire. One hundred seventy-one (10.1%) patients had a positive screening test for hazardous drinking (an AUDIT-C score of 5 or greater) and 64 (3.8%) for harmful drinking. Clinicians suspected alcohol problems in 81 patients (hazardous drinking in 37, harmful drinking in 40, and both in 4). The sensitivity of clinician suspicion of either hazardous or harmful drinking was 27% and the specificity was 98%. Positive and negative predictive values were 62% and 92%, respectively. CONCLUSION Clinician suspicion of alcohol problems had poor sensitivity but high specificity for identifying patients who had a positive screening test for alcohol problems. These data support the routine use of a screening tool to supplement clinicians’ suspicions, which already provide reasonable positive predictive value. PMID:23319506

  3. Ab initio study of energy transfer rates and impact sensitivities of crystalline explosives.

    PubMed

    Bernstein, Jonathan

    2018-02-28

    Impact sensitivities of various crystalline explosives were predicted by means of plane wave-density functional theory calculations. Crystal structures and complete vibrational spectra of TATB, PETN, FOX7, TEX, 14DNI, and β-HMX molecular crystals were calculated. A correlation between the phonon-vibron coupling (which is proportionally related to the energy transfer rate between the phonon manifold and the intramolecular vibrational modes) and impact sensitivities of secondary explosives was found. We propose a method, based on ab initio calculations, for the evaluation of impact sensitivities, which consequently can assist in screening candidates for chemical synthesis of high energetic materials.

  4. Ab initio study of energy transfer rates and impact sensitivities of crystalline explosives

    NASA Astrophysics Data System (ADS)

    Bernstein, Jonathan

    2018-02-01

    Impact sensitivities of various crystalline explosives were predicted by means of plane wave-density functional theory calculations. Crystal structures and complete vibrational spectra of TATB, PETN, FOX7, TEX, 14DNI, and β-HMX molecular crystals were calculated. A correlation between the phonon-vibron coupling (which is proportionally related to the energy transfer rate between the phonon manifold and the intramolecular vibrational modes) and impact sensitivities of secondary explosives was found. We propose a method, based on ab initio calculations, for the evaluation of impact sensitivities, which consequently can assist in screening candidates for chemical synthesis of high energetic materials.

  5. Associations of reward sensitivity with food consumption, activity pattern, and BMI in children.

    PubMed

    De Decker, Annelies; Sioen, Isabelle; Verbeken, Sandra; Braet, Caroline; Michels, Nathalie; De Henauw, Stefaan

    2016-05-01

    In the current study, the associations of reward sensitivity with weight related behaviors and body mass index were investigated in a general population sample of 443 Flemish children (50.3% boys) aged 5.5-12 years. Cross-sectional data on palatable food consumption frequency, screen time, physical activity, parental education level and measured length and weight were collected. The Drive subscale of the 'Behavioral Inhibition Scale/Behavioral Activation Scale' was used as a short method to measure reward sensitivity. A significant positive association of reward sensitivity with the fast food and sweet drink consumption frequency was found. Furthermore, a significant positive association of reward sensitivity with the z-score of body mass index was demonstrated, which explained additional variance to the variance explained by palatable food consumption frequency, screen time, physical activity and parental education level. Hence, the assessment of reward sensitivity may have an added value to the assessment of weight-related behavior indicators when evaluating the determinants of overweight in a child. In sum, children high in reward sensitivity might be more attracted to fast food and sweet drinks, and hence, might be more vulnerable to develop unfavorable food habits and overweight. These findings suggest that considering inter-individual differences in reward sensitivity is of importance in future childhood obesity prevention campaigns. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population

    PubMed Central

    Wahl, Jochen; Barleon, Lorenz; Morfeld, Peter; Lichtmeß, Andrea; Haas-Brähler, Sibylle; Pfeiffer, Norbert

    2016-01-01

    Purpose To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). Methods 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into “no glaucoma”, “possible glaucoma” and “probable glaucoma” was defined as “gold standard”. A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Values and relationships of CDR and IOP and the FDT were considered additionally and a glaucoma score was generated. The structure of the screening model was specified a priori whereas values of the parameters were chosen post-hoc to optimize sensitivity and specificity of the algorithm. Simple screening models based on IOP and / or FDT were investigated for comparison. Results 111 persons (2.66%) were classified as glaucoma suspects, thereof 13 (0.31%) as probable and 98 (2.35%) as possible glaucoma suspects by the expert. Re-evaluation by the screening model revealed a sensitivity of 83.8% and a specificity of 99.6% for all glaucoma suspects. The positive predictive value of the model was 80.2%, the negative predictive value 99.6%. Simple screening models showed insufficient diagnostic accuracy. Conclusion Adjustment of ONH and symmetry parameters with respect to excavation and IOP in an expert system produced sufficiently satisfying diagnostic accuracy. This screening model seems to be applicable in such a working population with relatively low age and low glaucoma prevalence. Different experts should validate the model in different populations. PMID:27479301

  7. Utilization of teledentistry as a tool to screen for dental caries among 12-year-old school children in a rural region of India.

    PubMed

    Purohit, Bharathi M; Singh, Abhinav; Dwivedi, Ashish

    2017-03-01

    The study aims to assess the reliability of video-graphic method as a tool to screen the dental caries among 12-year-old school children in a rural region of India. A total of 139 school children participated in the study. Visual tactile examinations were conducted using the Decayed, Missing, and Filled Teeth (DMFT) index. Simultaneously, standardized video recording of the oral cavity was performed. Sensitivity and specificity values were calculated for video-graphic assessment of dental caries. Bland-Altman plot was used to assess agreement between the two methods of caries assessment. Likelihood ratio (LR) and receiver-operating characteristic (ROC) curve were used to assess the predictive accuracy of the video-graphic method. Mean DMFT for the study population was 2.47 ± 2.01 and 2.46 ± 1.91 by visual tactile and video-graphic assessment (P = 0.76; > 0.05). Sensitivity and specificity values of 0.86 and 0.58 were established for video-graphic assessment. A fair degree of agreement was noted between the two methods with Intraclass correlation coefficient (ICC) value of 0.56. LR for video-graphic assessment was 2.05. Bland-Altman plot confirmed the level of agreement between the two assessment methods. The area under curve was 0.69 (CI 0.57, 0.80, P = 0.001). Teledentistry examination is comparable to clinical examination when screening for dental caries among school children. This study provides evidence that teledentistry may be used as an alternative screening tool for assessment of dental caries and is viable for remote consultation and treatment planning. Teledentistry offers to change the dynamics of dental care delivery and may effectively bridge the rural-urban oral health divide. © 2016 American Association of Public Health Dentistry.

  8. Rapid screening for human-pathogenic Mucorales using rolling circle amplification.

    PubMed

    Dolatabadi, S; Najafzadeh, M J; de Hoog, G S

    2014-12-01

    Mucormycosis has emerged as a relatively common severe mycosis in patients with haematological and allogeneic stem cell transplantation. Source of transmission is from unidentified sources in the environment. Early diagnosis of infection and its source of contamination are paramount for rapid and appropriate therapy. In this study, rolling circle amplification (RCA) is introduced as a sensitive, specific and reproducible isothermal DNA amplification technique for rapid molecular identification of six of the most virulent species (Rhizopus microsporus, R. arrhizus var. arrhizus, R. arrhizus var. delemar, Mucor irregularis, Mucor circinelloides, Lichtheimia ramosa, Lichtheimia corymbifera). DNAs of target species were successfully amplified, with no cross reactivity between species. RCA can be considered as a rapid detection method with high specificity and sensitivity, suitable for large screening. © 2014 Blackwell Verlag GmbH.

  9. Physical and genetic-interaction density reveals functional organization and informs significance cutoffs in genome-wide screens

    PubMed Central

    Dittmar, John C.; Pierce, Steven; Rothstein, Rodney; Reid, Robert J. D.

    2013-01-01

    Genome-wide experiments often measure quantitative differences between treated and untreated cells to identify affected strains. For these studies, statistical models are typically used to determine significance cutoffs. We developed a method termed “CLIK” (Cutoff Linked to Interaction Knowledge) that overlays biological knowledge from the interactome on screen results to derive a cutoff. The method takes advantage of the fact that groups of functionally related interacting genes often respond similarly to experimental conditions and, thus, cluster in a ranked list of screen results. We applied CLIK analysis to five screens of the yeast gene disruption library and found that it defined a significance cutoff that differed from traditional statistics. Importantly, verification experiments revealed that the CLIK cutoff correlated with the position in the rank order where the rate of true positives drops off significantly. In addition, the gene sets defined by CLIK analysis often provide further biological perspectives. For example, applying CLIK analysis retrospectively to a screen for cisplatin sensitivity allowed us to identify the importance of the Hrq1 helicase in DNA crosslink repair. Furthermore, we demonstrate the utility of CLIK to determine optimal treatment conditions by analyzing genome-wide screens at multiple rapamycin concentrations. We show that CLIK is an extremely useful tool for evaluating screen quality, determining screen cutoffs, and comparing results between screens. Furthermore, because CLIK uses previously annotated interaction data to determine biologically informed cutoffs, it provides additional insights into screen results, which supplement traditional statistical approaches. PMID:23589890

  10. An improvement of LLNA:DA to assess the skin sensitization potential of chemicals.

    PubMed

    Zhang, Hongwei; Shi, Ying; Wang, Chao; Zhao, Kangfeng; Zhang, Shaoping; Wei, Lan; Dong, Li; Gu, Wen; Xu, Yongjun; Ruan, Hongjie; Zhi, Hong; Yang, Xiaoyan

    2017-01-01

    We developed a modified local lymph node assay based on ATP (LLNA:DA), termed the Two-Stage LLNA:DA, to further reduce the animal numbers in the identification of sensitizers. In the Two-Stage LLNA:DA procedure, 13 chemicals ranging from non-sensitizers to extreme sensitizers were selected. The first stage used reduced LLNA:DA (rLLNA:DA) to screen out sensitive chemicals. The second stage used LLNA:DA based on OECD 442 (A) to classify those potential sensitizers screened out in the first stage. In the first stage, the SIs of the methyl methacrylate, salicylic acid, methyl salicylate, ethyl salicylate, isopropanol and propanediol were below 1.8 and need not to be tested in the second step. Others continued to be tested by LLNA:DA. In the second stage, sodium lauryl sulphate and xylene were classified as weak sensitizers. a-hexyl cinnamic aldehyde and eugenol were moderate sensitizers. Benzalkonium chloride and glyoxal were strong sensitizers, and phthalic anhydride was an extreme sensitizer. The 9/9, 11/12, 10/11, and 8/13 (positive or negative only) categories of the Two-Stage LLNA:DA were consistent with those from the other methods (LLNA, LLNA:DA, GPMT/BT and HMT/HPTA), suggesting that Two-Stage LLNA:DA have a high coincidence rate with reported data. In conclusion, The Two-Stage LLNA:DA is in line with the "3R" rules, and can be a modification of LLNA:DA but needs more study.

  11. Concurrent evaluation of visual, cytological and HPV testing as screening methods for the early detection of cervical neoplasia in Mumbai, India.

    PubMed

    Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R

    2005-03-01

    Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.

  12. Familial Breast/Ovarian Cancer and BRCA1/2 Genetic Screening: The Role of Immunohistochemistry as an Additional Method in the Selection of Patients

    PubMed Central

    Vaz, Fátima H.; Machado, Patrícia M.; Brandão, Rita D.; Laranjeira, Cátia T.; Eugénio, Joana S.; Fernandes, Aires H.; André, Saudade P.

    2007-01-01

    Only 20–25% of families screened for BRCA1/2 mutations are found positive. Because only a positive result is informative, we studied the role of BRCA1/2 immunohistochemistry as an additional method for patient selection. From 53 high-risk-affected probands, 18 (34%) had available paraffin blocks of their tumors and were selected for this study. Mutation screening was done by conformation-sensitive gel electrophoresis and multiplex ligation-dependent probe amplification. For immunohistochemistry, 21 neoplastic specimens (15 breast carcinomas, 5 ovary neoplasms, and 1 rectal adenocarcinoma) were analyzed with BRCA1 (monoclonal antibody, Ab-1, oncogene) and BRCA2 (polyclonal antibody, Ab-2, oncogene) antibodies. Absence of the BRCA1 protein was confirmed in negative tumors by Western blotting. Seven patients were positive for BRCA1/2 mutations: 5 for BRCA1 and 2 for BRCA2. Four out of five positive patients had tumors negative for BRCA1 immunostaining, and the remaining 13 BRCA1-negative patients had positive BRCA1 immunostaining in all tumor samples. Sensitivity to predict for BRCA1 mutation carriers was 80%, and specificity was 100%, with a positive predictive value of 100% and a negative predictive value of 93%. This correlation was statistically significant (p=0.001). No correlation was observed for BRCA2. If larger studies confirm these results, high-risk patients with BRCA1-negative tumors should be screened first for this gene. PMID:17625228

  13. Fasting capillary blood glucose: an appropriate measurement in screening for diabetes and pre-diabetes in low-resource rural settings.

    PubMed

    Zhao, X; Zhao, W; Zhang, H; Li, J; Shu, Y; Li, S; Cai, L; Zhou, J; Li, Y; Hu, R

    2013-01-01

    To evaluate the efficiency of fasting capillary blood glucose (FCG) measurement as compared with fasting venous plasma glucose (FPG) measurement in screening diabetes and pre-diabetes in low-resource rural settings. In 2010, 993 participants were randomly selected from 9 villages in Yunnan province using cluster sampling method. Samples for FCG and FPG test were obtained after demographics and physical examination. The oral glucose tolerance test was performed in parallel as gold standard for diagnosis. Diagnostic capacities of the FCG measurement in predicting undiagnosed diabetes and pre-diabetes were assessed. The performance of FCG and FPG tests was compared. Fifty-seven individuals with undiagnosed diabetes and 145 subjects with pre-diabetes were detected. The concordance between FCG and FPG levels was high (r = 0.75, p < 0.001). The area under the curve (AUC) for FCG test in predicting diabetes was 0.88 [95% confidence interval (CI) 0.82-0.93] with the optimal cutoff value of 5.65 mmol/l, sensitivity of 84.2%, and specificity of 79.3%. The corresponding values in FPG tests were 0.92 (95% CI 0.88-0.97) (AUC), 6.51 mmol/l (optimal cutoff point), 82.5% (sensitivity) and 98.3% (specificity), respectively. No significant difference was found in the AUC for the two screening strategies. FCG measurement is considered to be a convenient, practicable screening method in low-resource rural communities with acceptable test properties.

  14. Clinical utility of a single-item test for DSM-5 alcohol use disorder among outpatients with anxiety and depressive disorders.

    PubMed

    Bartoli, Francesco; Crocamo, Cristina; Biagi, Enrico; Di Carlo, Francesco; Parma, Francesca; Madeddu, Fabio; Capuzzi, Enrico; Colmegna, Fabrizia; Clerici, Massimo; Carrà, Giuseppe

    2016-08-01

    There is a lack of studies testing accuracy of fast screening methods for alcohol use disorder in mental health settings. We aimed at estimating clinical utility of a standard single-item test for case finding and screening of DSM-5 alcohol use disorder among individuals suffering from anxiety and mood disorders. We recruited adults consecutively referred, in a 12-month period, to an outpatient clinic for anxiety and depressive disorders. We assessed the National Institute on Alcohol Abuse and Alcoholism (NIAAA) single-item test, using the Mini- International Neuropsychiatric Interview (MINI), plus an additional item of Composite International Diagnostic Interview (CIDI) for craving, as reference standard to diagnose a current DSM-5 alcohol use disorder. We estimated sensitivity and specificity of the single-item test, as well as positive and negative Clinical Utility Indexes (CUIs). 242 subjects with anxiety and mood disorders were included. The NIAAA single-item test showed high sensitivity (91.9%) and specificity (91.2%) for DSM-5 alcohol use disorder. The positive CUI was 0.601, whereas the negative one was 0.898, with excellent values also accounting for main individual characteristics (age, gender, diagnosis, psychological distress levels, smoking status). Testing for relevant indexes, we found an excellent clinical utility of the NIAAA single-item test for screening true negative cases. Our findings support a routine use of reliable methods for rapid screening in similar mental health settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. The sensitivity and specificity of subjective memory complaints and the subjective memory rating scale, deterioration cognitive observee, mini-mental state examination, six-item screener and clock drawing test in dementia screening.

    PubMed

    Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J

    2013-01-01

    The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.

  16. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia.

    PubMed

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-09-01

    Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.

  17. Detection of anti-PL-12 autoantibodies by ELISA using a recombinant antigen; study of the immunoreactive region

    PubMed Central

    García-Lozano, J R; González-Escribano, M F; Rodríguez, R; Rodriguez-Sanchez, J L; Targoff, I N; Wichmann, I; Núñez-Roldán, A

    1998-01-01

    Autoantibodies to aminoacyl-tRNA synthetases are highly associated with myositis and detection is important in clinical diagnosis; however, current methods of screening limit its clinical utility. In the present study, alanyl-tRNA synthetase (PL-12) recombinant protein was obtained by immunological screening of a HeLa expression library and used in an ELISA with 22 anti-PL-12 sera, 200 autoimmune sera negative for PL-12 and 100 healthy individual sera. Sensitivity of the method was 95% (21/22) and specificity 100%. Mapping of the immunoreactive region was carried out using three anti-PL-12 sera and different recombinant protein-derived peptides. Results show that the same conformational epitope located within amino acids 730–951 of the PL-12 antigen outside the catalytic region was recognized by the three anti-PL-12 sera tested. We conclude that ELISA using recombinant protein is an effective and useful method for routine screening for anti-PL-12 autoantibodies. PMID:9822271

  18. A Multiplexed Serum Biomarker Immunoassay Panel Discriminates Clinical Lung Cancer Patients from High-Risk Individuals Found to be Cancer-Free by CT Screening

    PubMed Central

    Bigbee, William L.; Gopalakrishnan, Vanathi; Weissfeld, Joel L.; Wilson, David O.; Dacic, Sanja; Lokshin, Anna E.; Siegfried, Jill M.

    2012-01-01

    Introduction Clinical decision-making in the setting of CT screening could benefit from accessible biomarkers that help predict the level of lung cancer risk in high-risk individuals with indeterminate pulmonary nodules. Methods To identify candidate serum biomarkers, we measured 70 cancer-related proteins by Luminex xMAP® multiplexed immunoassays in a training set of sera from 56 patients with biopsy-proven primary non small cell lung cancer and 56 age-, sex- and smoking-matched CT-screened controls. Results We identified a panel of 10 serum biomarkers – prolactin, transthyretin, thrombospondin-1, E-selectin, C-C motif chemokine 5, macrophage migration inhibitory factor, plasminogen activator inhibitor, receptor tyrosine-protein kinase, Cyfra 21.1, and serum amyloid A – that distinguished lung cancer from controls with an estimated balanced accuracy (average of sensitivity and specificity) of 76.0%±3.8% from 20-fold internal cross-validation. We then iteratively evaluated this model in independent test and verification case/control studies confirming the initial classification performance of the panel. The classification performance of the 10-biomarker panel was also analytically validated using ELISAs in a second independent case/control population further validating the robustness of the panel. Conclusions The performance of this 10-biomarker panel based model was 77.1% sensitivity/76.2% specificity in cross-validation in the expanded training set, 73.3% sensitivity/93.3% specificity (balanced accuracy 83.3%) in the blinded verification set with the best discriminative performance in Stage I/II cases: 85% sensitivity (balanced accuracy 89.2%). Importantly, the rate of misclassification of CT-screened controls was not different in most control subgroups with or without airflow obstruction or emphysema or pulmonary nodules. These biomarkers have potential to aid in the early detection of lung cancer and more accurate interpretation of indeterminate pulmonary nodules detected by screening CT. PMID:22425918

  19. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    PubMed

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  20. A Redox Sensitive Pathway in the Mouse ES Cell Assay Modeled From ToxCast HTS Data

    EPA Science Inventory

    The broad chemical landscape coupled with the lack of developmental toxicity information across most environmental chemicals has motivated the need for high- throughput screening methods and predictive models of developmental toxicity. Towards this end, we used the mouse embryoni...

  1. [Effectiveness of FTA Elute® indicating cartridge in combination with hybrid capture 2 for cervical cancer screening].

    PubMed

    Chen, Feng; Zhang, Xi; Wang, Shaoming; Hu, Shangying; Chen, Wen; Zhao, Fanghui; He, Wei; Zhang, Yuqing; Qiao, Youlin

    2015-02-01

    To evaluate the effectiveness of FTA Elute® Cartridge (GE healthcare, Kent, UK) in combination with hybrid capture 2 (HC2) testing for cervical cancer screening. From May to June 2012, 412 women aged 25 to 65 years in Jiangxi Tonggu were enrolled in the study. We used pathological outcome as the gold standard, and the accuracy of the FTA card in combination with HC2 testing was investigated from both physician- and self-sampling, respectively. Physician sampling using the FTA card in combination with HC2 testing showed a comparable sensitivity (12/13) with the liquid based medium, but a higher specificity 69.5% (266/383) vs (77.8%, 298/383) (P < 0.001).When self sampling method was used, the sensitivity and specificity of using the FTA card in combination with HC2 testing with liquid based medium was 10/13 vs 8/13(P = 0.625) and (62.3%, 238/382) vs (75.7%, 289/382) (P < 0.001). The agreement of detection results for HC2 between FTA and liquid-based sampling medium was 86.1% (340/395) and 79.5% (314/395). For physician-collected samples used for HC2 testing to detect CIN2+, the accuracy of the FTA card was superior to that of the liquid-based medium (area under the receiver operating characteristic curve (AUC) = 0.898, 95%CI:0.838-0.958). FTA Elute® cartridge in combination with HC2 testing is a promising method of specimen transport for cervical cancer screening programs with a good precision.With further optimization, it could become an effective method for cervical cancer screening in various economic levels of areas.

  2. Validation of an ELISA Synthetic Cannabinoids Urine Assay.

    PubMed

    Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A

    2015-10-01

    Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.

  3. Sensitivity analysis of a short distance atmospheric dispersion model applied to the Fukushima disaster

    NASA Astrophysics Data System (ADS)

    Périllat, Raphaël; Girard, Sylvain; Korsakissok, Irène; Mallet, Vinien

    2015-04-01

    In a previous study, the sensitivity of a long distance model was analyzed on the Fukushima Daiichi disaster case with the Morris screening method. It showed that a few variables, such as horizontal diffusion coefficient or clouds thickness, have a weak influence on most of the chosen outputs. The purpose of the present study is to apply a similar methodology on the IRSN's operational short distance atmospheric dispersion model, called pX. Atmospheric dispersion models are very useful in case of accidental releases of pollutant to minimize the population exposure during the accident and to obtain an accurate assessment of short and long term environmental and sanitary impact. Long range models are mostly used for consequences assessment while short range models are more adapted to the early phases of the crisis and are used to make prognosis. The Morris screening method was used to estimate the sensitivity of a set of outputs and to rank the inputs by their influences. The input ranking is highly dependent on the considered output, but a few variables seem to have a weak influence on most of them. This first step revealed that interactions and non-linearity are much more pronounced with the short range model than with the long range one. Afterward, the Sobol screening method was used to obtain more quantitative results on the same set of outputs. Using this method was possible for the short range model because it is far less computationally demanding than the long range model. The study also confronts two parameterizations, Doury's and Pasquill's models, to contrast their behavior. The Doury's model seems to excessively inflate the influence of some inputs compared to the Pasquill's model, such as the altitude of emission and the air stability which do not have the same role in the two models. The outputs of the long range model were dominated by only a few inputs. On the contrary, in this study the influence is shared more evenly between the inputs.

  4. Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms

    PubMed Central

    Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish

    2014-01-01

    Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224

  5. An evaluation of a rapid real time polymerase chain reaction assay for detection of group B streptococcus as part of a neonatal group B streptococcus prevention strategy.

    PubMed

    Money, Deborah; Dobson, Simon; Cole, Lesley; Karacabeyli, Eda; Blondel-Hill, Edith; Milner, Ruth; Thomas, Eva

    2008-09-01

    To evaluate the sensitivity, specificity, and feasibility of a rapid real-time polymerase chain reaction (PCR) test for group B streptococcus (GBS) completed during labour, compared with the standard culture test performed at 35 to 37 weeks' gestation. Women presenting to the maternity unit for term vaginal delivery had two vaginal/rectal samples collected. One swab was tested using a rapid PCR method (IDI-Strep B, Infectio Diagnostic [IDI] Inc., Sainte-Foy QC ), and the other was cultured after enrichment (intrapartum culture). Comparisons were made between these results and those of a culture-based screen at 35 to 37 weeks' gestation. Of the 190 women enrolled, 85% had results of the standard screen at 35 to 37 weeks available for comparison. The sensitivity and specificity of the standard 35- to 37-week screen were 84.3% (95% confidence interval [CI], 71.4-93.0) and 93.2% (95% CI 86.5-97.2) respectively, whereas the sensitivity and specificity of the rapid PCR were 90.7% (95% CI 79.7-96.9) and 97.6% (95% CI 93.1-99.5), respectively. The median reporting time for the rapid PCR test was 99 minutes (range 50-255). Results were available more than four hours before delivery in 81% of cases. In this Canadian centre, a rapid PCR test done at the time of labour (IDI-Strep B) demonstrated high sensitivity and specificity, comparable to the 35- to 37-week screen. The time to reporting results was acceptably short, allowing for timely administration of intrapartum prophylactic antibiotics.

  6. Diagnostic accuracy of high-risk HPV DNA genotyping for primary cervical cancer screening and triage of HPV-positive women, compared to cytology: preliminary results of the PIPAVIR study.

    PubMed

    Chatzistamatiou, Kimon; Moysiadis, Theodoros; Angelis, Eleftherios; Kaufmann, Andreas; Skenderi, Alkmini; Jansen-Duerr, Pidder; Lekka, Irini; Kilintzis, Vasilis; Angelidou, Stamatia; Katsiki, Evangelia; Hagemann, Ingke; Tsertanidou, Athena; Koch, Isabel; Boecher, Oliver; Soutschek, Erwin; Maglaveras, Nikolaos; Agorastos, Theodoros

    2017-05-01

    The purpose of the presented PIPAVIR (persistent infections with human papillomaviruses; http://www.pipavir.com ) subanalysis is to assess the performance of high-risk (hr) HPV-DNA genotyping as a method of primary cervical cancer screening and triage of HPV positive women to colposcopy compared to liquid-based cytology (LBC) in an urban female population. Women, aged 30-60, provided cervicovaginal samples at the Family-Planning Centre, Hippokratio Hospital of Thessaloniki, Greece, and the Department of Gynecology and Obstetrics in Mare Klinikum, Kiel, Germany. Cytology and HPV genotyping was performed using LBC and HPV Multiplex Genotyping (MPG), respectively. Women positive for cytology [atypical squamous cells of undetermined significance (ASC-US) or worse] or hrHPV were referred for colposcopy. Among 1723/1762 women included in the final analysis, hrHPV and HPV16/18 prevalence was 17.7 and 9.6%, respectively. Cytology was ASCUS or worse in 7.6%. Cervical Intraepithelial Neoplasia grade 2 or worse (CIN2+) was detected in 28 women (1.6%). Sensitivity of cytology (ASCUS or worse) and HPV DNA testing for the detection of CIN2+ was 50.0 and 100%, and specificity was 94.49 and 85.49%, respectively. The screening approach according to which only women positive for HPV16/18 and for hrHPV(non16/18) with ASCUS or worse were referred to colposcopy presented 78.57% sensitivity and 13.17% positive predictive value (PPV). HPV testing represents a more sensitive methodology for primary cervical cancer screening compared to cytology. For triage of HPV positive women to colposcopy, partial HPV genotyping offers better sensitivity than cytology, at the cost of higher number of colposcopies.

  7. Rapid screening of guar gum using portable Raman spectral identification methods.

    PubMed

    Srivastava, Hirsch K; Wolfgang, Steven; Rodriguez, Jason D

    2016-01-25

    Guar gum is a well-known inactive ingredient (excipient) used in a variety of oral pharmaceutical dosage forms as a thickener and stabilizer of suspensions and as a binder of powders. It is also widely used as a food ingredient in which case alternatives with similar properties, including chemically similar gums, are readily available. Recent supply shortages and price fluctuations have caused guar gum to come under increasing scrutiny for possible adulteration by substitution of cheaper alternatives. One way that the U.S. FDA is attempting to screen pharmaceutical ingredients at risk for adulteration or substitution is through field-deployable spectroscopic screening. Here we report a comprehensive approach to evaluate two field-deployable Raman methods--spectral correlation and principal component analysis--to differentiate guar gum from other gums. We report a comparison of the sensitivity of the spectroscopic screening methods with current compendial identification tests. The ability of the spectroscopic methods to perform unambiguous identification of guar gum compared to other gums makes them an enhanced surveillance alternative to the current compendial identification tests, which are largely subjective in nature. Our findings indicate that Raman spectral identification methods perform better than compendial identification methods and are able to distinguish guar gum from other gums with 100% accuracy for samples tested by spectral correlation and principal component analysis. Published by Elsevier B.V.

  8. Application of a High Throughput Method of Biomarker Discovery to Improvement of the EarlyCDT®-Lung Test

    PubMed Central

    Macdonald, Isabel K.; Murray, Andrea; Healey, Graham F.; Parsy-Kowalska, Celine B.; Allen, Jared; McElveen, Jane; Robertson, Chris; Sewell, Herbert F.; Chapman, Caroline J.; Robertson, John F. R.

    2012-01-01

    Background The National Lung Screening Trial showed that CT screening for lung cancer led to a 20% reduction in mortality. However, CT screening has a number of disadvantages including low specificity. A validated autoantibody assay is available commercially (EarlyCDT®-Lung) to aid in the early detection of lung cancer and risk stratification in patients with pulmonary nodules detected by CT. Recent advances in high throughput (HTP) cloning and expression methods have been developed into a discovery pipeline to identify biomarkers that detect autoantibodies. The aim of this study was to demonstrate the successful clinical application of this strategy to add to the EarlyCDT-Lung panel in order to improve its sensitivity and specificity (and hence positive predictive value, (PPV)). Methods and Findings Serum from two matched independent cohorts of lung cancer patients were used (n = 100 and n = 165). Sixty nine proteins were initially screened on an abridged HTP version of the autoantibody ELISA using protein prepared on small scale by a HTP expression and purification screen. Promising leads were produced in shake flask culture and tested on the full assay. These results were analyzed in combination with those from the EarlyCDT-Lung panel in order to provide a set of re-optimized cut-offs. Five proteins that still displayed cancer/normal differentiation were tested for reproducibility and validation on a second batch of protein and a separate patient cohort. Addition of these proteins resulted in an improvement in the sensitivity and specificity of the test from 38% and 86% to 49% and 93% respectively (PPV improvement from 1 in 16 to 1 in 7). Conclusion This is a practical example of the value of investing resources to develop a HTP technology. Such technology may lead to improvement in the clinical utility of the EarlyCDT­-Lung test, and so further aid the early detection of lung cancer. PMID:23272083

  9. A Comparative Analysis of Coprologic Diagnostic Methods for Detection of Toxoplama gondii in Cats

    PubMed Central

    Salant, Harold; Spira, Dan T.; Hamburger, Joseph

    2010-01-01

    The relative role of transmission of Toxoplasma gondii infection from cats to humans appears to have recently increased in certain areas. Large-scale screening of oocyst shedding in cats cannot rely on microscopy because oocyst identification lacks sensitivity and specificity, or on bioassays, which require test animals and weeks before examination. We compared a sensitive and species-specific coprologic–polymerase chain reaction (copro-PCR) for detection of T. gondii infected cats with microscopy and a bioassay. In experimentally infected cats followed over time, microscopy was positive occasionally, and positive copro-PCR and bioassay results were obtained continuously from days 2 to 24 post-infection. The copro-PCR is at least as sensitive and specific as the bioassay and is capable of detecting infective oocysts during cat infection. Therefore, this procedure can be used as the new gold standard for determining potential cat infectivity. Its technologic advantages over the bioassay make it superior for large-scale screening of cats. PMID:20439968

  10. Mutation screening of the CDKL5 gene in cryptogenic infantile intractable epilepsy and review of clinical sensitivity.

    PubMed

    Intusoma, Utcharee; Hayeeduereh, Fadell; Plong-On, Oradawan; Sripo, Thanya; Vasiknanonte, Punnee; Janjindamai, Supachai; Lusawat, Apasri; Thammongkol, Sasipa; Visudtibhan, Anannit; Limprasert, Pornprot

    2011-09-01

    To perform CDKL5 mutation screening in Thai children with cryptogenic infantile intractable epilepsy and to determine the clinical sensitivity of CDKL5 screening when different inclusion criteria were applied. Children with cryptogenic infantile intractable epilepsy were screened for CDKL5 mutation using multiplex ligation-dependent probe amplification and DNA sequencing. The clinical sensitivity was reviewed by combining the results of studies using similar inclusion screening criteria. Thirty children (19 girls and 11 boys) with a median seizure onset of 7 months were screened. Almost a half had infantile spasms and one fifth had stereotypic hand movements. A novel c.2854C>T (p.R952X) was identified in an ambulatory girl who had severe mental retardation, multiple types of seizures without Rett-like features. Her mother had a mild intellectual disability, yet her grandmother and half sister were normal despite having the same genetic alteration (random X-inactivation patterns). The pathogenicity of p.R952X identified here was uncertain since healthy relatives and 6 female controls also harbor this alteration. The clinical sensitivity of CDKL5 mutation screening among females with Rett-like features and negative MECP2 screening was 7.8% while the clinical sensitivity among females having cryptogenic intractable seizures with an onset before the ages of 12, 6 and 3 months were 4.7, 11.6 and 14.3%, respectively. Copyright © 2011 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  11. Weak cation magnetic separation technology and MALDI-TOF-MS in screening serum protein markers in primary type I osteoporosis.

    PubMed

    Shi, X L; Li, C W; Liang, B C; He, K H; Li, X Y

    2015-11-30

    We investigated weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of primary type I osteoporosis. We selected 16 postmenopausal women with osteoporosis and nine postmenopausal women as controls to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were obtained from controls and patients. Serum protein was extracted with the WCX protein chip system; protein fingerprints were examined using MALDI-TOF-MS. The preprocessed and model construction data were handled by the ProteinChip system. The diagnostic models were established using a genetic arithmetic model combined with a support vector machine (SVM). The SVM model with the highest Youden index was selected. Combinations with the highest accuracy in distinguishing different groups of data were selected as potential biomarkers. From the two groups of serum proteins, 123 cumulative MS protein peaks were selected. Significant intensity differences in the protein peaks of 16 postmenopausal women with osteoporosis were screened. The difference in Youden index between the four groups of protein peaks showed that the highest peaks had mass-to-charge ratios of 8909.047, 8690.658, 13745.48, and 15114.52. A diagnosis model was established with these four markers as the candidates, and the model specificity and sensitivity were found to be 100%. Two groups of specimens in the SVM results on the scatterplot were distinguishable. We established a diagnosis model, and provided a new serological method for screening and diagnosis of osteoporosis with high sensitivity and specificity.

  12. The accuracy and efficiency of electronic screening for recruitment into a clinical trial on COPD.

    PubMed

    Schmickl, Christopher N; Li, Man; Li, Guangxi; Wetzstein, Marnie M; Herasevich, Vitaly; Gajic, Ognjen; Benzo, Roberto P

    2011-10-01

    Participant recruitment is an important process in successful conduct of randomized controlled trials. To facilitate enrollment into a National Institutes of Health-sponsored clinical trial involving patients with chronic obstructive pulmonary disease (COPD), we developed and prospectively validated an automated electronic screening tool based on boolean free-text search of admission notes in electronic medical records. During a 2-week validation period, all patients admitted to prespecified general medical services were screened for eligibility by both the electronic screening tool and a COPD nurse. Group discussion was the gold standard for confirmation of true-positive results. Compared with the gold standard, electronic screening yielded 100% sensitivity, 92% specificity, 100% negative predictive value, and 72% positive predictive value. Compared with traditional manual screening, electronic screening demonstrated time-saving potential of 76%. Thus, the electronic screening tool accurately identifies potential study subjects and improves efficiency of patient accrual for a clinical trial on COPD. This method may be expanded into other institutional and clinical settings. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Rhythm-based heartbeat duration normalization for atrial fibrillation detection.

    PubMed

    Islam, Md Saiful; Ammour, Nassim; Alajlan, Naif; Aboalsamh, Hatim

    2016-05-01

    Screening of atrial fibrillation (AF) for high-risk patients including all patients aged 65 years and older is important for prevention of risk of stroke. Different technologies such as modified blood pressure monitor, single lead ECG-based finger-probe, and smart phone using plethysmogram signal have been emerging for this purpose. All these technologies use irregularity of heartbeat duration as a feature for AF detection. We have investigated a normalization method of heartbeat duration for improved AF detection. AF is an arrhythmia in which heartbeat duration generally becomes irregularly irregular. From a window of heartbeat duration, we estimate the possible rhythm of the majority of heartbeats and normalize duration of all heartbeats in the window based on the rhythm so that we can measure the irregularity of heartbeats for both AF and non-AF rhythms in the same scale. Irregularity is measured by the entropy of distribution of the normalized duration. Then we classify a window of heartbeats as AF or non-AF by thresholding the measured irregularity. The effect of this normalization is evaluated by comparing AF detection performances using duration with the normalization, without normalization, and with other existing normalizations. Sensitivity and specificity of AF detection using normalized heartbeat duration were tested on two landmark databases available online and compared with results of other methods (with/without normalization) by receiver operating characteristic (ROC) curves. ROC analysis showed that the normalization was able to improve the performance of AF detection and it was consistent for a wide range of sensitivity and specificity for use of different thresholds. Detection accuracy was also computed for equal rates of sensitivity and specificity for different methods. Using normalized heartbeat duration, we obtained 96.38% accuracy which is more than 4% improvement compared to AF detection without normalization. The proposed normalization method was found useful for improving performance and robustness of AF detection. Incorporation of this method in a screening device could be crucial to reduce the risk of AF-related stroke. In general, the incorporation of the rhythm-based normalization in an AF detection method seems important for developing a robust AF screening device. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Extrasolar planets as a probe of modified gravity

    NASA Astrophysics Data System (ADS)

    Vargas dos Santos, Marcelo; Mota, David F.

    2017-06-01

    We propose a new method to test modified gravity theories, taking advantage of the available data on extrasolar planets. We computed the deviations from the Kepler third law and use that to constrain gravity theories beyond General Relativity. We investigate gravity models which incorporate three screening mechanisms: the Chameleon, the Symmetron and the Vainshtein. We find that data from exoplanets orbits are very sensitive to the screening mechanisms putting strong constraints in the parameter space for the Chameleon models and the Symmetron, complementary and competitive to other methods, like interferometers and solar system. With the constraints on Vainshtein we are able to work beyond the hypothesis that the crossover scale is of the same order of magnitude than the Hubble radius rc ∼ H0-1, which makes the screening work automatically, testing how strong this hypothesis is and the viability of other scales.

  15. Molecular Detection of Invasive Species in Heterogeneous Mixtures Using a Microfluidic Carbon Nanotube Platform

    PubMed Central

    Mahon, Andrew R.; Barnes, Matthew A.; Senapati, Satyajyoti; Feder, Jeffrey L.; Darling, John A.; Chang, Hsueh-Chia; Lodge, David M.

    2011-01-01

    Screening methods to prevent introductions of invasive species are critical for the protection of environmental and economic benefits provided by native species and uninvaded ecosystems. Coastal ecosystems worldwide remain vulnerable to damage from aquatic species introductions, particularly via ballast water discharge from ships. Because current ballast management practices are not completely effective, rapid and sensitive screening methods are needed for on-site testing of ships in transit. Here, we describe a detection technology based on a microfluidic chip containing DNA oligonucleotide functionalized carbon nanotubes. We demonstrate the efficacy of the chip using three ballast-transported species either established (Dreissena bugensis) or of potential threat (Eriocheir sinensis and Limnoperna fortuneii) to the Laurentian Great Lakes. With further refinement for on-board application, the technology could lead to real-time ballast water screening to improve ship-specific management and control decisions. PMID:21364993

  16. Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors.

    PubMed

    Shahshahani, Hayedeh J; Meraat, Nahid; Mansouri, Fatemeh

    2013-07-01

    Haemoglobin screening methods need to be highly sensitive to detect both low and high haemoglobin levels and avoid unnecessary rejection of potential blood donors. The aim of this study was to evaluate the accuracy of measurements by HemoCue in blood donors. Three hundred and fourteen randomly selected, prospective blood donors were studied. Single fingerstick blood samples were obtained to determine the donors' haemoglobin levels by HemoCue, while venous blood samples were drawn for measurement of the haemoglobin level by both HemoCue and an automated haematology analyser as the reference method. The sensitivity, specificity, predictive values and correlation between the reference method and HemoCue were assessed. Cases with a haemoglobin concentration in the range of 12.5-17.9 g/dL were accepted for blood donation. Analysis of paired results showed that haemoglobin levels measured by HemoCue were higher than those measured by the reference method. There was a significant correlation between the reference method and HemoCue for haemoglobin levels less than 12.5 g/dL. The correlation was less strong for increasing haemoglobin levels. Linear correlation was poor for haemoglobin levels over 18 g/dL. Thirteen percent of donors, who had haemoglobin levels close to the upper limit, were unnecessarily rejected. HemoCue is suitable for screening for anaemia in blood donors. Most donors at Yazd are males and a significant percentage of them have haemoglobin values close to the upper limit for acceptance as a blood donor; since these subjects could be unnecessarily rejected on the basis of HemoCue results and testing with this method is expensive, it is recommended that qualitative methods are used for primary screening and accurate quantitative methods used in clinically suspicious cases or when qualitative methods fail.

  17. Digital Rectal Examination and Balloon Expulsion Test in the Study of Defecatory Disorders: Are They Suitable as Screening or Excluding Tests?

    PubMed

    Caetano, Ana C; Santa-Cruz, André; Rolanda, Carla

    2016-01-01

    Background . Rome III criteria add physiological criteria to symptom-based criteria of chronic constipation (CC) for the diagnosis of defecatory disorders (DD). However, a gold-standard test is still lacking and physiological examination is expensive and time-consuming. Aim . Evaluate the usefulness of two low-cost tests-digital rectal examination (DRE) and balloon expulsion test (BET)-as screening or excluding tests of DD. Methods . We performed a systematic search in PUBMED and MEDLINE. We selected studies where constipated patients were evaluated by DRE or BET. Heterogeneity was assessed and random effect models were used to calculate the sensitivity, specificity, and negative predictive value (NPV) of the DRE and the BET. Results . Thirteen studies evaluating BET and four studies evaluating DRE (2329 patients) were selected. High heterogeneity ( I 2 > 80%) among studies was demonstrated. The studies evaluating the BET showed a sensitivity and specificity of 67% and 80%, respectively. Regarding the DRE, a sensitivity of 80% and specificity of 84% were calculated. NPV of 72% for the BET and NPV of 64% for the DRE were estimated. The sensitivity and specificity were similar when we restrict the analysis to studies using Rome criteria to define CC. The BET seems to perform better when a cut-off time of 2 minutes is used and when it is compared with a combination of physiological tests. Considering the DRE, strict criteria seem to improve the sensitivity but not the specificity of the test. Conclusion . Neither of the low-cost tests seems suitable for screening or excluding DD.

  18. The novel measuring method for screening and assessing chromium content in clothes and shoes materials

    NASA Astrophysics Data System (ADS)

    Salerno-Kochan, R.

    2017-10-01

    The aim of this paper is to propose the bioindicative measuring method for screening and assessing the safety of textile and leather materials in relation to chemical threats. This method is based on toxicological assay in which Tetrahymena pyriformis, unicellular organism belonging to protozoans, is used as a test organism. For the realization of the research goal the sensitivity threshold of test organisms to chromium(VI) solutions was identified. The changes in cell development of test organisms in chromium solutions were registered by colorimetric measurements in the presence of alamarBlue® cell viability reagent. Empirical data enabled to fit logistic curves on the base of which the level of chromium toxicity was estimated. In the second step, harmfulness of aqueous extracts obtained from textile and leather samples containing chromium in relation to test organisms was evaluated. The performed research confirmed the high efficiency of the proposed method in screening and assessing chromium content in clothes and shoes materials and showed possibilities of using it in safety assessment of products with regard to chemical risks.

  19. Comparison of Enzyme-Linked Immunosorbent Assay, Surface Plasmon Resonance and Biolayer Interferometry for Screening of Deoxynivalenol in Wheat and Wheat Dust

    PubMed Central

    Sanders, Melanie; McPartlin, Daniel; Moran, Kara; Guo, Yirong; Eeckhout, Mia; O’Kennedy, Richard; De Saeger, Sarah; Maragos, Chris

    2016-01-01

    A sample preparation method was developed for the screening of deoxynivalenol (DON) in wheat and wheat dust. Extraction was carried out with water and was successful due to the polar character of DON. For detection, an enzyme-linked immunosorbent assay (ELISA) was compared to the sensor-based techniques of surface plasmon resonance (SPR) and biolayer interferometry (BLI) in terms of sensitivity, affinity and matrix effect. The matrix effects from wheat and wheat dust using SPR were too high to further use this screenings method. The preferred ELISA and BLI methods were validated according to the criteria established in Commission Regulation 519/2014/EC and Commission Decision 2002/657/EC. A small survey was executed on 16 wheat lots and their corresponding dust samples using the validated ELISA method. A linear correlation (r = 0.889) was found for the DON concentration in dust versus the DON concentration in wheat (LOD wheat: 233 μg/kg, LOD wheat dust: 458 μg/kg). PMID:27077883

  20. Sesquiterpene lactone dermatitis in the young: is atopy a risk factor?

    PubMed

    Paulsen, Evy; Otkjaer, Aksel; Andersen, Klaus E

    2008-07-01

    Screening for Compositae contact allergy has documented fairly high prevalence in adults, and recent studies indicate that the allergy may be more common in children than previously believed. However, detailed information on sensitization in this age group is sparse. The objective of this study was to present another 2 cases in children and review the literature. Screening with sesquiterpene lactone (SL) mix has shown prevalence of 0.5% and 1.8% in 2 studies, while screening with 2 different Compositae mixes detected 4.2% and 2.6% positives among children and adolescents. All individual case reports describe sensitization in atopic children, and the largest screening study showed a prevalence of Compositae mix sensitization that was significantly higher in children with atopic dermatitis compared with non-atopics. Compositae sensitization should be considered in children with a family or personal history of atopy, summer-related, or -exacerbated dermatitis of any kind, and a history of plant exposure. Screening with SL mix is recommended but should be supplemented with plant extracts based on exposure history. Compositae weeds, especially dandelions, seem to be important sensitizers in children.

  1. Cost-effectiveness analysis of mammography and clinical breast examination strategies

    PubMed Central

    Ahern, Charlotte Hsieh; Shen, Yu

    2009-01-01

    Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473

  2. Screening for sepsis in general hospitalized patients: a systematic review.

    PubMed

    Alberto, L; Marshall, A P; Walker, R; Aitken, L M

    2017-08-01

    Sepsis is a condition widely observed outside critical care areas. To examine the application of sepsis screening tools for early recognition of sepsis in general hospitalized patients to: (i) identify the accuracy of these tools; (ii) determine the outcomes associated with their implementation; and (iii) describe the implementation process. A systematic review method was used. PubMed, CINAHL, Cochrane, Scopus, Web of Science, and Embase databases were systematically searched for primary articles, published from January 1990 to June 2016, that investigated screening tools or alert mechanisms for early identification of sepsis in adult general hospitalized patients. The review protocol was registered with PROSPERO (CRD42016042261). More than 8000 citations were screened for eligibility after duplicates had been removed. Six articles met the inclusion criteria testing two types of sepsis screening tools. Electronic tools can capture, recognize abnormal variables, and activate an alert in real time. However, accuracy of these tools was inconsistent across studies with only one demonstrating high specificity and sensitivity. Paper-based, nurse-led screening tools appear to be more sensitive in the identification of septic patients but were only studied in small samples and particular populations. The process of care measures appears to be enhanced; however, demonstrating improved outcomes is more challenging. Implementation details are rarely reported. Heterogeneity of studies prevented meta-analysis. Clinicians, researchers and health decision-makers should consider these findings and limitations when implementing screening tools, research or policy on sepsis recognition in general hospitalized patients. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Primary care validation of a single-question alcohol screening test.

    PubMed

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  4. Screening for sexually transmitted infection pathogens in semen samples

    PubMed Central

    Peeling, RW; Embree, J

    2005-01-01

    The transmission of sexually transmitted infection (STI) pathogens from an infected donor to the recipient of a semen donation in assisted conception may result not only in acute infection but also in long-term reproductive complications or adverse outcomes of pregnancy, including infection of the offspring. Screening for bacterial STI pathogens, Chlamydia trachomatis and Neisseria gonorrhoeae is strongly recommended because these pathogens can cause serious reproductive complications in the recipients of semen donations and infection in their offspring. Screening for these pathogens should be performed using the most sensitive methods, such as nucleic acid amplified tests. False-negative results due to inhibitory substances in the semen sample should be monitored using amplification controls. Where specimen transport is not a problem and culture facilities are available, N gonorrhoeae can also be detected by culture. Laboratories performing screening should subscribe to proficiency programs and have strict quality controls. Although Trichomonas vaginalis, group B streptococcus and genital mycoplasmas have been associated with adverse outcomes of pregnancy, the frequent finding of these organisms in healthy individuals brings into question the validity of mandatory inclusion of these organisms in the screening panel. Although viral STI pathogens and Treponema pallidum - the causative agent of syphilis - may be detected in semen, their presence may be more sensitively detected through antibody testing of the donor. Screening donors for HIV, hepatitis B and syphilis by serology is uniformly recommended in all of the guidelines, but the value of screening either donors or semen samples for cytomegalovirus, herpes simplex viruses and human papilloma viruses is less clear. PMID:18159531

  5. Anxiety and Depression Screening for Youth in a Primary Care Population

    PubMed Central

    Katon, Wayne; Joan, Russo; Richardson, Laura; McCauley, Elizabeth; Lozano, Paula

    2008-01-01

    Objective Prior studies have shown a low rate of accurate identification by primary care physicians of mental health disorders in youth. This study tested the psychometric properties of two brief mental health screening questionnaires, the Mood and Feelings Questionnaire – Short Form (MFQ-SF) and Childhood Anxiety Sensitivity Index (ASI), in a large sample of youth. Methods In a sample of 1375 youth age 11 to 17 (779 with asthma, 596 randomly selected controls) enrolled in an HMO, the psychometric properties (optimum cutoffs on Receiver Operating Curve (ROC) curves, sensitivity, specificity, positive and negative predictive values) of two brief anxiety and depression screens were examined versus a “gold standard” structured psychiatric interview. Results Both the MFQ-SF and ASI performed well on ROC analysis for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better on ROC analysis than the ASI for youth with major depression (area under the curve of 0.84 vs 0.77). For screening youth with anxiety disorders ROC curves showed that both the MFQ-SF and ASI only performed in the fair range (area under the curve of 0.76). Conclusion The MFQ-SF and ASI are two relatively brief questionnaires that performed well for screening youth for one or more DSM-IV anxiety or depressive disorders. The MFQ-SF performed better than the ASI for screening youth with major depression. Use of these instruments could increase the accuracy of identification of mental health disorders in youth by primary care physicians. PMID:18501865

  6. The Abbreviated Mental Test 4 for cognitive screening of older adults presenting to the Emergency Department.

    PubMed

    Dyer, Adam H; Briggs, Robert; Nabeel, Shamis; O'Neill, Desmond; Kennelly, Sean P

    2017-12-01

    A commonly cited reason for the infrequent detection of cognitive impairment in the Emergency Department (ED) is the lack of an appropriate screening tool. The Abbreviated Mental Test 4 (AMT4) is a brief instrument recommended for cognitive screening of older adults in the ED. However, its exact utility in the detection of altered mental status in the ED is yet to be fully determined. The present study evaluated the ability of the AMT4 to identify impaired mental status in the ED, defined as positive scores on either the Confusion Assessment Method-ICU for delirium, the standardized Mini Mental State Examination as a general cognitive screener or the Eight-item Interview to Differentiate Aging and Dementia for dementia. Of 196 adults at least 70 years of age (mean: 78.5±5.9), the AMT4 had a sensitivity of 0.53 (0.42-0.63) and a specificity of 0.96 (0.89-0.99) for impaired mental status in the ED. The AMT4 was positive in almost all patients (92%; 24/26) screening positive for delirium, but less than half (47.8%; 22/46) of those screening positive for probable dementia, and less than a quarter (22.2%; 6/27) of those screening positive for probable cognitive impairment. The present study found that the limited sensitivity of the AMT4 in identifying the majority of cognitively impaired persons restricts its use in isolation as a general cognitive screener in the ED.

  7. Local-global classifier fusion for screening chest radiographs

    NASA Astrophysics Data System (ADS)

    Ding, Meng; Antani, Sameer; Jaeger, Stefan; Xue, Zhiyun; Candemir, Sema; Kohli, Marc; Thoma, George

    2017-03-01

    Tuberculosis (TB) is a severe comorbidity of HIV and chest x-ray (CXR) analysis is a necessary step in screening for the infective disease. Automatic analysis of digital CXR images for detecting pulmonary abnormalities is critical for population screening, especially in medical resource constrained developing regions. In this article, we describe steps that improve previously reported performance of NLM's CXR screening algorithms and help advance the state of the art in the field. We propose a local-global classifier fusion method where two complementary classification systems are combined. The local classifier focuses on subtle and partial presentation of the disease leveraging information in radiology reports that roughly indicates locations of the abnormalities. In addition, the global classifier models the dominant spatial structure in the gestalt image using GIST descriptor for the semantic differentiation. Finally, the two complementary classifiers are combined using linear fusion, where the weight of each decision is calculated by the confidence probabilities from the two classifiers. We evaluated our method on three datasets in terms of the area under the Receiver Operating Characteristic (ROC) curve, sensitivity, specificity and accuracy. The evaluation demonstrates the superiority of our proposed local-global fusion method over any single classifier.

  8. Alu–based cell-free DNA: a novel biomarker for screening of gastric cancer

    PubMed Central

    Zhao, Jianmei; Shen, Xianjuan; Jing, Rongrong; Yu, Juan; Li, Li; Shi, Yingjuan; Zhang, Lurong; Wang, Zhiwei; Cong, Hui

    2017-01-01

    Gastric cancer (GC) is the fourth most common cancer and the second major cause of cancer-related deaths worldwide. In our previous study, a novel and sensitive method for quantifying cell-free DNA (CFD) in human blood was established and tested for its ability to predict patients with tumor. We want to investigate CFD expression in the sera of GC patients in an attempt to explore the clinical significance of CFD in improving the early screening of GC and monitoring GC progression by the branched DNA (bDNA)-based Alu assay. The concentration of CFD was quantitated by bDNA-based Alu assay. CEA, CA19-9, C72-4 and CA50 concentrations were determined by ABBOTT ARCHITECT I2000 SR. We found the CFD concentrations have significant differences between GC patients, benign gastric disease (BGD) patients and healthy controls (P < 0.05). CFD were weakly correlated with CEA (r = −0.197, P < 0.05) or CA50 (r = 0.206, P < 0.05), and no correlation with CA19-9 (r = −0.061, P > 0.05) or CA72-4 (r = 0.011, P > 0.05). In addition, CFD concentrations were significantly higher in stage I GC patients than BGD patients and healthy controls (P < 0.05), but there was no significant difference in CEA, CA19-9 and CA50 among the three traditional tumor markers (P > 0.05). Our analysis showed that CFD was more sensitive than CEA, CA19-9, CA72-4 or CA50 in early screening of GC. Compared with CEA, CA19-9, CA72-4 and CA50, CFD may prove to be a better biomarker for the screening of GC, thus providing a sensitive biomarker for screening and monitoring progression of GC. PMID:28903321

  9. Cost-Effectiveness of Double Reading versus Single Reading of Mammograms in a Breast Cancer Screening Programme

    PubMed Central

    Posso, Margarita; Carles, Misericòrdia; Rué, Montserrat; Puig, Teresa; Bonfill, Xavier

    2016-01-01

    Objectives The usual practice in breast cancer screening programmes for mammogram interpretation is to perform double reading. However, little is known about its cost-effectiveness in the context of digital mammography. Our purpose was to evaluate the cost-effectiveness of double reading versus single reading of digital mammograms in a population-based breast cancer screening programme. Methods Data from 28,636 screened women was used to establish a decision-tree model and to compare three strategies: 1) double reading; 2) double reading for women in their first participation and single reading for women in their subsequent participations; and 3) single reading. We calculated the incremental cost-effectiveness ratio (ICER), which was defined as the expected cost per one additionally detected cancer. We performed a deterministic sensitivity analysis to test the robustness of the ICER. Results The detection rate of double reading (5.17‰) was similar to that of single reading (4.78‰; P = .768). The mean cost of each detected cancer was €8,912 for double reading and €8,287 for single reading. The ICER of double reading versus single reading was €16,684. The sensitivity analysis showed variations in the ICER according to the sensitivity of reading strategies. The strategy that combines double reading in first participation with single reading in subsequent participations was ruled out due to extended dominance. Conclusions From our results, double reading appears not to be a cost-effective strategy in the context of digital mammography. Double reading would eventually be challenged in screening programmes, as single reading might entail important net savings without significantly changing the cancer detection rate. These results are not conclusive and should be confirmed in prospective studies that investigate long-term outcomes like quality adjusted life years (QALYs). PMID:27459663

  10. Screening for Autism Spectrum Disorders in Children With Down Syndrome

    PubMed Central

    DiGuiseppi, Carolyn; Hepburn, Susan; Davis, Jonathan M.; Fidler, Deborah J.; Hartway, Sara; Lee, Nancy Raitano; Miller, Lisa; Ruttenber, Margaret; Robinson, Cordelia

    2015-01-01

    Objective We assessed the prevalence of autism spectrum disorders (ASD) and screening test characteristics in children with Down syndrome. Method Eligible children born in a defined geographic area between January 1, 1996, and December 31, 2003, were recruited through a population-based birth defects registry and community outreach, then screened with the modified checklist for autism in toddlers or social communication questionnaire, as appropriate. Screen-positive children and a random sample of screen-negative children underwent developmental evaluation. Results We screened 123 children (27.8% of the birth cohort). Mean age was 73.4 months (range, 31–142). Compared to screen-negative children, screen-positive children had similar sociodemo-graphic characteristics but a lower mean developmental quotient (mean difference: 11.0; 95% confidence interval: 4.8–17.3). Weighted prevalences of autistic disorder and total ASD were 6.4% (95% confidence interval [CI]: 2.6%–11.6%) and 18.2% (95% CI: 9.7%–26.8%), respectively. The estimated minimum ASD prevalence, accounting for unscreened children, is 5.1% (95% CI: 3.3%–7.4%). ASD prevalence increased with greater cognitive impairment. Screening test sensitivity was 87.5% (95% CI: 66.6%–97.7%); specificity was 49.9% (95% CI: 37.0%–61.4%). Conclusion The prevalence of ASD among children with Down syndrome aged 2 to 11 years is substantially higher than in the general population. The modified checklist for autism in toddlers and social communication questionnaire were highly sensitive in children with Down syndrome but could result in many false positive tests if universal screening were implemented using current algorithms. Research needs include development of specific ASD screening algorithms and improved diagnostic discrimination in children with Down syndrome. Timely identification of these co-occurring diagnoses is essential so appropriate interventions can be provided. PMID:20375732

  11. Comparison of three screening tests for autism in preterm children with birth weights less than 1,500 grams

    PubMed Central

    Dudova, Iva; Markova, Daniela; Kasparova, Martina; Zemankova, Jana; Beranova, Stepanka; Urbanek, Tomas; Hrdlicka, Michal

    2014-01-01

    Background Preterm children seem to be at increased risk for autism spectrum disorders (ASD). Methods Parents of 157 children with birth weights less than 1,500 g (age 2 years, corrected for prematurity; 88 boys, 69 girls) completed screening questionnaires. The screening battery included the Modified Checklist for Autism in Toddlers (M-CHAT), Communication and Symbolic Behavior Scales Developmental Profile Infant-Toddler Checklist (CSBS-DP-ITC), and the Infant/Toddler Sensory Profile (ITSP). Children with disabilities were excluded. All children who screened positive on any of the screening tools were subsequently assessed by clinical examination including the Autism Diagnostic Observation Schedule. Results Fifty-six children (35.7%) screened positive on at least one of the parental screening questionnaires. Of the 56 children who tested positive, 33 participated in the detailed clinical follow-up assessment. A diagnosis of ASD was confirmed in 13 of the 33 children. The ASD prevalence was 9.7% of the sample. Analysis of children with and without an ASD diagnosis found significant differences relative to gestational age (26.9 weeks vs 28.3 weeks, P=0.033) and length of the stay in hospital (89.5 days vs 75.4 days, P=0.042). The screening tool with the most positive results was CSBS-DP-ITC (42 positive screens [PS]), followed by M-CHAT (28 PS), and ITSP (22 PS). Differences in the frequency of PS among the tests were significant (P=0.008). CSBS-DP-ITC had the highest sensitivity (0.846), followed by M-CHAT (0.692) and ITSP (0.462). Conclusion Our results indicate a higher prevalence of autism in children with birth weights <1,500 g at 2 years of age compared to the general population prevalence. The ASD diagnosis was associated with shorter gestation times and longer hospital stays. Our findings support the simultaneous use of more than one screening tests in order to increase screening sensitivity. PMID:25484588

  12. Screening protocol for dysphagia in adults: comparison with videofluoroscopic findings.

    PubMed

    Sassi, Fernanda C; Medeiros, Gisele C; Zilberstein, Bruno; Jayanthi, Shri Krishna; de Andrade, Claudia R F

    2017-12-01

    To compare the videofluoroscopic findings of patients with suspected oropharyngeal dysphagia with the results of a clinical screening protocol. A retrospective observational cohort study was conducted on all consecutive patients with suspected oropharyngeal dysphagia between March 2015 and February 2016 who were assigned to receive a videofluoroscopic assessment of swallowing. All patients were first submitted to videofluoroscopy and then to the clinical assessment of swallowing. The clinical assessment was performed within the first 24 hours after videofluoroscopy. The videofluoroscopy results were analyzed regarding penetration/aspiration using an 8-point multidimensional perceptual scale. The accuracy of the clinical protocol was analyzed using the sensitivity, specificity, likelihood ratios and predictive values. The selected sample consisted of 50 patients. The clinical protocol presented a sensitivity of 50% and specificity of 95%, with an accuracy of 88%. "Cough" and "wet-hoarse" vocal quality after/during swallowing were clinical indicators that appeared to correctly identify the presence of penetration/aspiration risk. The clinical protocol used in the present study is a simple, rapid and reliable clinical assessment. Despite the absence of a completely satisfactory result, especially in terms of the sensitivity and positive predictive values, we suggest that lower rates of pneumonia can be achieved using a formal dysphagia screening method.

  13. Impedimetric detection of cocaine by using an aptamer attached to a screen printed electrode modified with a dendrimer/silver nanoparticle nanocomposite.

    PubMed

    Roushani, Mahmoud; Shahdost-Fard, Faezeh

    2018-03-12

    The authors describe a highly sensitive method for the aptamer (Apt) based impedimetric determination of cocaine. The surface of a screen-printed electrode (SPE) was modified with a nanocomposite of dendrimer and silver nanoparticles (AgNPs). The cocaine-binding Apt was attached to a dendrimer/AgNP/SPE surface, forming a sensitive layer for the determination of cocaine. The incubation with the analyte resulted in the formation of a cocaine/Apt complex on the electrode surface. As a consequence, folding and conformational change in the aptamer structure was induced, this resulting in a change in the impedimetric signal. The aptaassay exhibits highly efficient sensing characteristics with a good linearity of 1 fmol L -1 to 100 nmol L -1 (with two linear ranges) and a limit of detection (LOD) of 333 amol L -1 . Its excellent specificity and high sensitivity suggest that this kind of aptamer-based assay may be applied to detect other targets in this field. Graphical Abstract Designing of an aptaassay via immobilization of a functionalized aptamer with silver nanoparticle (AgNPs-Apt) on the modified screen-printed electrode (SPE) with dendrimer/silver nanoparticle nanocomposite (Den-AgNPs) for impedimetric detection of cocaine.

  14. Based on surface-enhanced Raman spectroscopy analysis of serum albumin in different stages of liver disease for early screening primary liver cancer

    NASA Astrophysics Data System (ADS)

    Liao, Fadian; Ruan, Qiuyong; Lin, Juqiang; Lin, Jinyong; Zeng, Yongyi; Li, Ling; Huang, Zufang; Liu, Nenrong; Chen, Rong

    2014-09-01

    Despite the introduction of high-technology methods of detection and diagnosis, screening of primary liver cancer (PLC) remains imperfect. To diagnosis PLC earlier, Surface-enhanced Raman spectroscopy (SERS) coupled with cellulose-acetate membrane electrophoresis were introduced to separate human serum albumin and SERS spectra. Three groups (15 normal persons' samples, 17 hepatitis/cirrhosis samples, 15 cases of PLC) of serum albumin were tested. Silver colloid was used to obtain SERS spectra of human serum albumin. Principal component analysis (PCA) and linear discriminant analysis (LDA) were also employed for statistical analysis. The mean Raman spectra of three groups and the difference spectra of any two suggested that the albumin has changed in liver patients. Compared to normal groups, some Raman peaks have shifted or even disappeared in hepatitis/cirrhosis and PLCs groups. The sensitivity and specificity between PLCs and normal groups is 80% and 93.3%. Among hepatitis/cirrhosis and normal groups, the sensitivity is 88.2% and specificity is also 93.3%. Besides, the sensitivity and specificity between PLCs and hepatitis/cirrhosis groups is 86.7% and 76.5%. All the above data and results indicated that early screening of PLC is potential by SERS in different stages of liver disease before cancer occurs.

  15. Musculoskeletal impairment survey in Rwanda: Design of survey tool, survey methodology, and results of the pilot study (a cross sectional survey)

    PubMed Central

    Atijosan, Oluwarantimi; Kuper, Hannah; Rischewski, Dorothea; Simms, Victoria; Lavy, Christopher

    2007-01-01

    Background Musculoskeletal impairment (MSI) is an important cause of morbidity and mortality worldwide, especially in developing countries. Prevalence studies for MSI in the developing world have used varying methodologies and are seldom directly comparable. This study aimed to develop a new tool to screen for and diagnose MSI and to pilot test the methodology for a national survey in Rwanda. Methods A 7 question screening tool to identify cases of MSI was developed through literature review and discussions with healthcare professionals. To validate the tool, trained rehabilitation technicians screened 93 previously identified gold standard 'cases' and 86 'non cases'. Sensitivity, specificity and positive predictive value were calculated. A standardised examination protocol was developed to determine the aetiology and diagnosis of MSI for those who fail the screening test. For the national survey in Rwanda, multistage cluster random sampling, with probability proportional to size procedures will be used for selection of a cross-sectional, nationally representative sample of the population. Households to be surveyed will be chosen through compact segment sampling and all individuals within chosen households will be screened. A pilot survey of 680 individuals was conducted using the protocol. Results: The screening tool demonstrated 99% sensitivity and 97% specificity for MSI, and a positive predictive value of 98%. During the pilot study 468 out of 680 eligible subjects (69%) were screened. 45 diagnoses were identified in 38 persons who were cases of MSI. The subjects were grouped into categories based on diagnostic subgroups of congenital (1), traumatic (17), infective (2) neurological (6) and other acquired(19). They were also separated into mild (42.1%), moderate (42.1%) and severe (15.8%) cases, using an operational definition derived from the World Health Organisation's International Classification of Functioning, Disability and Health. Conclusion: The screening tool had good sensitivity and specificity and was appropriate for use in a national survey. The pilot study showed that the survey protocol was appropriate for measuring the prevalence of MSI in Rwanda. This survey is an important step to building a sound epidemiological understanding of MSI, to enable appropriate health service planning. PMID:17391509

  16. Cyquant cell proliferation assay as a fluorescence-based method for in vitro screening of antimalarial activity.

    PubMed

    Sriwilaijaroen, Nongluk; Kelly, Jane Xu; Riscoe, Michael; Wilairat, Prapon

    2004-12-01

    The appearance of drug resistant parasites and the absence of an effective vaccine have resulted in the need for new effective antimalarial drugs. Consequently, a convenient method for in vitro screening of large numbers of antimalarial drug candidates has become apparent. The CyQUANT cell proliferation assay is a highly sensitive fluorescence-based method for quantitation of cell number by measuring the strong fluorescence produced when green GR dye binds to nucleic acids. We have applied the CyQUANT assay method to evaluate the growth of Plasmodium falciparum D6 strain in culture. The GR-nucleic acid fluorescence linearly correlated with percent parasitemia at both 0.75 or 1 percent hematocrit with the same correlation coefficient of r2 = 0.99. The sensitivity of P. falciparum D6 strain to chloroquine and to 3,6-bis-omega-diethylaminoamyloxyxanthone, a novel antimalarial, determined by the CyQUANT assay were comparable to those obtained by the traditional [3H]-ethanolamine assay: IC50 value of chloroquine was 54 nM and 51 nM by the CyQUANT and [3H]-ethanolamine assay, respectively; IC50 value for 3,6-bis-omega-diethylaminoamyloxyxanthone was 254 nM and 223 nM by the CyQUANT and [3H]-ethanolamine assay, respectively. This procedure requires no radioisotope, uses simple equipment, and is an easy and convenient procedure, with no washing and harvesting steps. Moreover, all procedures can be set up continuously and thus, the CyQUANT assay is suitable in automatic high through-put drug screening of antimalarial drugs.

  17. Cross-national comparison of screening mammography accuracy measures in U.S., Norway, and Spain.

    PubMed

    Domingo, Laia; Hofvind, Solveig; Hubbard, Rebecca A; Román, Marta; Benkeser, David; Sala, Maria; Castells, Xavier

    2016-08-01

    To compare accuracy measures for mammographic screening in Norway, Spain, and the US. Information from women aged 50-69 years who underwent mammographic screening 1996-2009 in the US (898,418 women), Norway (527,464), and Spain (517,317) was included. Screen-detected cancer, interval cancer, and the false-positive rates, sensitivity, specificity, positive predictive value (PPV) for recalls (PPV-1), PPV for biopsies (PPV-2), 1/PPV-1 and 1/PPV-2 were computed for each country. Analyses were stratified by age, screening history, time since last screening, calendar year, and mammography modality. The rate of screen-detected cancers was 4.5, 5.5, and 4.0 per 1000 screening exams in the US, Norway, and Spain respectively. The highest sensitivity and lowest specificity were reported in the US (83.1 % and 91.3 %, respectively), followed by Spain (79.0 % and 96.2 %) and Norway (75.5 % and 97.1 %). In Norway, Spain and the US, PPV-1 was 16.4 %, 9.8 %, and 4.9 %, and PPV-2 was 39.4 %, 38.9 %, and 25.9 %, respectively. The number of women needed to recall to detect one cancer was 20.3, 6.1, and 10.2 in the US, Norway, and Spain, respectively. Differences were found across countries, suggesting that opportunistic screening may translate into higher sensitivity at the cost of lower specificity and PPV. • Positive predictive value is higher in population-based screening programmes in Spain and Norway. • Opportunistic mammography screening in the US has lower positive predictive value. • Screening settings in the US translate into higher sensitivity and lower specificity. • The clinical burden may be higher for women screened opportunistically.

  18. Use of the Dynamic Visual Acuity Test as a screener for community-dwelling older adults who fall.

    PubMed

    Honaker, Julie A; Shepard, Neil T

    2011-01-01

    Adequate function of the peripheral vestibular system, specifically the vestibulo-ocular reflex (VOR; a network of neural connections between the peripheral vestibular system and the extraocular muscles) is essential for maintaining stable vision during head movements. Decreased visual acuity resulting from an impaired peripheral vestibular system may impede balance and postural control and place an individual at risk of falling. Therefore, sensitive measures of the vestibular system are warranted to screen for the tendency to fall, alerting clinicians to recommend further risk of falling assessment and referral to a falling risk reduction program. Dynamic Visual Acuity (DVA) testing is a computerized VOR assessment method to evaluate the peripheral vestibular system during head movements; reduced visual acuity as documented with DVA testing may be sensitive to screen for falling risk. This study examined the sensitivity and specificity of the computerized DVA test with yaw plane head movements for identifying community-dwelling adults (58-78 years) who are prone to falling. A total of 16 older adults with a history of two or more unexplained falls in the previous twelve months and 16 age and gender matched controls without a history of falls in the previous twelve months participated. Computerized DVA with horizontal head movements at a fixed velocity of 120 deg/sec was measured and compared with the Dynamic Gait Index (DGI) a gold standard gait assessment measurement for identifying falling risk. Receiver operating characteristics (ROC) curve analysis and area under the ROC curve (AUC) were used to assess the sensitivity and specificity of the computerized DVA as a screening measure for falling risk as determined by the DGI. Results suggested a link between computerized DVA and the propensity to fall; DVA in the yaw plane was found to be a sensitive (92%) and accurate screening measure when using a cutoff logMAR value of >0.25.

  19. Development of a qPCR direct detection method for Listeria monocytogenes in milk

    USDA-ARS?s Scientific Manuscript database

    There is a growing movement among consumers in the US and Europe towards minimally processed foods, including raw milk and dairy products. This trend significantly increases exposure to dairy-borne pathogens and indicates a need for rapid, sensitive screening tests for raw dairy products to reduce ...

  20. Fatty acid ethyl esters (FAEEs) as markers for alcohol in meconium: method validation and implementation of a screening program for prenatal drug exposure.

    PubMed

    Hastedt, Martin; Krumbiegel, Franziska; Gapert, René; Tsokos, Michael; Hartwig, Sven

    2013-09-01

    Alcohol consumption during pregnancy is a widespread problem and can cause severe fetal damage. As the diagnosis of fetal alcohol syndrome is difficult, the implementation of a reliable marker for alcohol consumption during pregnancy into meconium drug screening programs would be invaluable. A previously published gas chromatography mass spectrometry method for the detection of fatty acid ethyl esters (FAEEs) as alcohol markers in meconium was optimized and newly validated for a sample size of 50 mg. This method was applied to 122 cases from a drug-using population. The meconium samples were also tested for common drugs of abuse. In 73 % of the cases, one or more drugs were found. Twenty percent of the samples tested positive for FAEEs at levels indicating significant alcohol exposure. Consequently, alcohol was found to be the third most frequently abused substance within the study group. This re-validated method provides an increase in testing sensitivity, is reliable and easily applicable as part of a drug screening program. It can be used as a non-invasive tool to detect high alcohol consumption in the last trimester of pregnancy. The introduction of FAEEs testing in meconium screening was found to be of particular use in a drug-using population.

  1. FAITH – Fast Assembly Inhibitor Test for HIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less

  2. A neurite quality index and machine vision software for improved quantification of neurodegeneration.

    PubMed

    Romero, Peggy; Miller, Ted; Garakani, Arman

    2009-12-01

    Current methods to assess neurodegradation in dorsal root ganglion cultures as a model for neurodegenerative diseases are imprecise and time-consuming. Here we describe two new methods to quantify neuroprotection in these cultures. The neurite quality index (NQI) builds upon earlier manual methods, incorporating additional morphological events to increase detection sensitivity for the detection of early degeneration events. Neurosight is a machine vision-based method that recapitulates many of the strengths of NQI while enabling high-throughput screening applications with decreased costs.

  3. Next-generation libraries for robust RNA interference-based genome-wide screens

    PubMed Central

    Kampmann, Martin; Horlbeck, Max A.; Chen, Yuwen; Tsai, Jordan C.; Bassik, Michael C.; Gilbert, Luke A.; Villalta, Jacqueline E.; Kwon, S. Chul; Chang, Hyeshik; Kim, V. Narry; Weissman, Jonathan S.

    2015-01-01

    Genetic screening based on loss-of-function phenotypes is a powerful discovery tool in biology. Although the recent development of clustered regularly interspaced short palindromic repeats (CRISPR)-based screening approaches in mammalian cell culture has enormous potential, RNA interference (RNAi)-based screening remains the method of choice in several biological contexts. We previously demonstrated that ultracomplex pooled short-hairpin RNA (shRNA) libraries can largely overcome the problem of RNAi off-target effects in genome-wide screens. Here, we systematically optimize several aspects of our shRNA library, including the promoter and microRNA context for shRNA expression, selection of guide strands, and features relevant for postscreen sample preparation for deep sequencing. We present next-generation high-complexity libraries targeting human and mouse protein-coding genes, which we grouped into 12 sublibraries based on biological function. A pilot screen suggests that our next-generation RNAi library performs comparably to current CRISPR interference (CRISPRi)-based approaches and can yield complementary results with high sensitivity and high specificity. PMID:26080438

  4. The Substance Abuse Subtle Screening Inventory-3 and Stages of Change: A Screening Validity Study

    ERIC Educational Resources Information Center

    Laux, John M.; Piazza, Nick J.; Salyers, Kathleen; Roseman, Christopher P.

    2012-01-01

    The sensitivity of the Substance Abuse Subtle Screening Inventory-3 (SASSI-3) was examined among substance-dependent adults enrolled in a family drug court. The SASSI-3 had a high sensitivity rate with this population, even across varying levels of motivation to change. (Contains 2 tables.)

  5. West Nile virus transmission via organ transplantation and blood transfusion - Louisiana, 2008.

    PubMed

    2009-11-20

    Three years after the introduction and spread of West Nile virus (WNV) in the United States, transmission through blood transfusion and solid organ transplantation was documented in 2002. Within a year, these findings led to nationwide screening of blood donors for WNV. Although screening is extremely sensitive, current methods still do not detect all WNV-infected blood donations, and organ donors are not screened routinely. In October 2008, the Louisiana Department of Health (LDH) was notified of a heart transplant recipient with suspected West Nile neuroinvasive disease (WNND). LDH launched an investigation to confirm the diagnosis and determine whether the organ recipient's infection was derived from the organ donor or blood products the donor received before organ donation. The investigation concluded that two cases of probable transfusion-transmitted WNV resulted from a common blood donor; one infection resulted in WNND via an organ donor, and the other resulted in asymptomatic WNV infection via blood transfusion directly. This investigation also found that criteria used by the blood-screening laboratory to screen the implicated blood donation for WNV were less stringent than criteria used by other blood collection centers in the area. Use of the more stringent screening criteria might have detected the WNV and prevented the blood donation from being used. To increase the likelihood of detecting WNV-positive donations, blood centers should use the most sensitive screening criteria feasible and communicate frequently with nearby blood centers on screening results during times of high WNV activity in their geographic area. In addition, health-care providers should consider WNND as a possible cause of neurologic complications in patients after blood transfusion or organ transplantation.

  6. Serology for Helicobacter pylori compared with symptom questionnaires in screening before direct access endoscopy.

    PubMed

    Mendall, M A; Jazrawi, R P; Marrero, J M; Molineaux, N; Levi, J; Maxwell, J D; Northfield, T C

    1995-03-01

    This prospective study aimed to compare serology for Helicobacter pylori with two, symptom questionnaires in screening patients before direct access endoscopy. Methods were compared in terms of the number of endoscopies saved and pathology missed in 315 patients referred to a gastroenterology unit by 65 local GPs. The serology used was based on an acid glycine extract of H pylori. One in-house questionnaire was based on the Glasgow dyspepsia (GLADYS) system and the other questionnaire was that reported by Holdstock et al. A cut off point of 6.3 U/ml for H pylori serology was selected for screening patients (97% sensitive and 75% specific). Serology was combined with a history of NSAID usage in determining who should have endoscopy. For the in-house questionnaire, a cut off score of more than 8 out of a possible maximum of 18 was chosen, after prior evaluation in 118 patients referred for direct access endoscopy (the sensitivity for detection of peptic ulcer was 88%, specificity 61%). A cut off score of more than 412 was used for the Holdstock questionnaire. In patients under 45 years, serology detected more peptic ulcers than the in-house questionnaire and the Holdstock questionnaire (27/28 v 24/28, NS and v 20/28, p < 0.05 respectively). The Holdstock questionnaire saved significantly more endoscopies than the other two methods (76/149 v 57/149 for the in-house questionnaire, p = 0.05 and 59/149 for serology, p = 0.05). In all age groups combined, serology was significantly better than the in-house and Holdstock questionnaires at detecting peptic ulcers and gastric cancer (61/63, 52/63, p<0.02, and 50/63, p<0.01 respectively). But serology saved significantly fewer endoscopies (89/315, 135/315, p<0.005, and 119/315, p<0.05 respectively). Serology was inferior to the Holdstock questionnaire at detecting severe oesophagitis. It is concluded that serology is the method of choice in screening before direct access upper gastrointestinal endoscopy in those under 45 years. It best combines a high sensitivity for peptic ulcer disease with a large reduction in unnecessary negative endoscopies.

  7. Cervical digital photography for screening of uterine cervix cancer and its precursor lesions in developing countries.

    PubMed

    Hillmann, Elise de Castro; Dos Reis, Ricardo; Monego, Heleusa; Appel, Márcia; Hammes, Luciano Serpa; Rivoire, Waldemar Augusto; Capp, Edison

    2013-07-01

    This study aims to evaluate and to compare the performance of cervical digital photography (CDP) to the visual inspection with acetic acid (VIA) and visual inspection with Lugol's iodine (VILI) methods for screening the uterine cervix cancer and its precursor lesions in developing countries. A cross-sectional study was performed in Brazil. 176 women were evaluated by VIA, VILI, CDP with acetic acid and CDP with Lugol's iodine. Kappa statistic was used to estimate the interobserver and intermethod agreement. Sensitivity, specificity and diagnostic accuracy of the four methods (VIA, VILI, CDP with acetic acid, CDP with Lugol's iodine) was calculated. Interobserver agreement for CDP with acetic acid was K = 0.441 and for CDP with Lugol's iodine was K = 0.533; intermethod agreement of VIA and CDP with acetic acid, K = 0.559; and of VILI and CDP with Lugol's iodine, K = 0.507. Sensitivity and specificity of CDP with acetic acid were 84.00 and 95.83 %, and of CDP with Lugol's iodine were 88.00 and 97.26 %, respectively. The diagnostic accuracy of CDP with acetic acid and CDP with Lugol's iodine was 92.78 and 94.90 %, respectively. This was the first study to assess the CDP with Lugol's iodine performance, which had similar performance to the CDP with acetic acid. CDP is considered a promising method for screening the uterine cervix cancer and its precursor lesions in developing countries.

  8. The Power of Neuroimaging Biomarkers for Screening Frontotemporal Dementia

    PubMed Central

    McMillan, Corey T.; Avants, Brian B.; Cook, Philip; Ungar, Lyle; Trojanowski, John Q.; Grossman, Murray

    2014-01-01

    Frontotemporal dementia (FTD) is a clinically and pathologically heterogeneous neurodegenerative disease that can result from either frontotemporal lobar degeneration (FTLD) or Alzheimer’s disease (AD) pathology. It is critical to establish statistically powerful biomarkers that can achieve substantial cost-savings and increase feasibility of clinical trials. We assessed three broad categories of neuroimaging methods to screen underlying FTLD and AD pathology in a clinical FTD series: global measures (e.g., ventricular volume), anatomical volumes of interest (VOIs) (e.g., hippocampus) using a standard atlas, and data-driven VOIs using Eigenanatomy. We evaluated clinical FTD patients (N=93) with cerebrospinal fluid, gray matter (GM) MRI, and diffusion tensor imaging (DTI) to assess whether they had underlying FTLD or AD pathology. Linear regression was performed to identify the optimal VOIs for each method in a training dataset and then we evaluated classification sensitivity and specificity in an independent test cohort. Power was evaluated by calculating minimum sample sizes (mSS) required in the test classification analyses for each model. The data-driven VOI analysis using a multimodal combination of GM MRI and DTI achieved the greatest classification accuracy (89% SENSITIVE; 89% SPECIFIC) and required a lower minimum sample size (N=26) relative to anatomical VOI and global measures. We conclude that a data-driven VOI approach employing Eigenanatomy provides more accurate classification, benefits from increased statistical power in unseen datasets, and therefore provides a robust method for screening underlying pathology in FTD patients for entry into clinical trials. PMID:24687814

  9. T-2 Toxin/HT-2 Toxin and Ochratoxin A ELISAs Development and In-House Validation in Food in Accordance with Commission Regulation (EU) No 519/2014

    PubMed Central

    Oplatowska-Stachowiak, Michalina; Sajic, Nermin; Haasnoot, Willem; Campbell, Katrina; Elliott, Christopher T.; Salden, Martin

    2017-01-01

    T-2 toxin/HT-2 toxin (T-2/HT-2) and ochratoxin A (OTA) are mycotoxins that can contaminate a variety of agricultural commodities. To protect consumers’ health, indicative limits for T-2/HT-2 and maximum limits for OTA have been set by the European Commission, requiring food business operators and controlling agencies to conduct routine checks for the presence of these harmful contaminants. Screening methods are increasingly used for monitoring purposes. Due to the demand for new and improved screening tools, two individual detection methods, T-2/HT-2 and OTA enzyme-linked immunosorbent assays (ELISAs), were developed in this study. The T-2/HT-2 ELISA was based on a T-2 monoclonal antibody with an IC50 (50% inhibitory concentration) of 0.28 ng/mL and 125% cross-reactivity with HT-2. As regards the OTA ELISA, a new sensitive monoclonal antibody specific to OTA with an IC50 of 0.13 ng/mL was produced. Both developed ELISA tests were then validated in agricultural commodities in accordance with the new performance criteria guidelines for the validation of screening methods for mycotoxins included in Commission Regulation (EU) No 519/2014. The T-2/HT-2 ELISA was demonstrated to be suitable for the detection of T-2/HT-2 in cereals and baby food at and above the screening target concentration (STC) of 12.5 μg/kg and 7.5 μg/kg, respectively. The OTA ELISA was shown to be applicable for the detection of OTA in cereals, coffee, cocoa and wine at and above the STC of 2 μg/kg, 2.5 μg/kg, 2.5 μg/kg and 0.4 ng/mL, respectively. The accuracy of both ELISAs was further confirmed by analysing proficiency test and reference samples. The developed methods can be used for sensitive and high-throughput screening for the presence of T-2/HT-2 and OTA in agricultural commodities. PMID:29189752

  10. T-2 Toxin/HT-2 Toxin and Ochratoxin A ELISAs Development and In-House Validation in Food in Accordance with the Commission Regulation (EU) No 519/2014.

    PubMed

    Oplatowska-Stachowiak, Michalina; Kleintjens, Tim; Sajic, Nermin; Haasnoot, Willem; Campbell, Katrina; Elliott, Christopher T; Salden, Martin

    2017-11-30

    T-2 toxin/HT-2 toxin (T-2/HT-2) and ochratoxin A (OTA) are mycotoxins that can contaminate a variety of agricultural commodities. To protect consumers' health, indicative limits for T-2/HT-2 and maximum limits for OTA have been set by the European Commission, requiring food business operators and controlling agencies to conduct routine checks for the presence of these harmful contaminants. Screening methods are increasingly used for monitoring purposes. Due to the demand for new and improved screening tools, two individual detection methods, T-2/HT-2 and OTA enzyme-linked immunosorbent assays (ELISAs), were developed in this study. The T-2/HT-2 ELISA was based on a T-2 monoclonal antibody with an IC 50 (50% inhibitory concentration) of 0.28 ng/mL and 125% cross-reactivity with HT-2. As regards the OTA ELISA, a new sensitive monoclonal antibody specific to OTA with an IC 50 of 0.13 ng/mL was produced. Both developed ELISA tests were then validated in agricultural commodities in accordance with the new performance criteria guidelines for the validation of screening methods for mycotoxins included in Commission Regulation (EU) No 519/2014. The T-2/HT-2 ELISA was demonstrated to be suitable for the detection of T-2/HT-2 in cereals and baby food at and above the screening target concentration (STC) of 12.5 μg/kg and 7.5 μg/kg, respectively. The OTA ELISA was shown to be applicable for the detection of OTA in cereals, coffee, cocoa and wine at and above the STC of 2 μg/kg, 2.5 μg/kg, 2.5 μg/kg and 0.4 ng/mL, respectively. The accuracy of both ELISAs was further confirmed by analysing proficiency test and reference samples. The developed methods can be used for sensitive and high-throughput screening for the presence of T-2/HT-2 and OTA in agricultural commodities.

  11. Effectiveness of the critical congenital heart disease screening program for early diagnosis of cardiac abnormalities in newborn infants.

    PubMed

    Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B

    2017-10-01

    To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants.  Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at  Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.

  12. Preliminary Evaluation of a Brief Autism Screener for Young Children

    PubMed Central

    Shenouda, Josephine; Mehta, Uday; Yee, Emily; Garcia, Patricia; Rajan, Mangala; Goldfarb, Madeleine

    2018-01-01

    ABSTRACT: Objective: Our objective was to assess the operating characteristics of the Psychological Development Questionnaire-1 (PDQ-1), an autism screener for use with young children. Methods: In Phase 1, we evaluated the concordance of the PDQ-1 with established autism scales, determined test-retest reliability, and identified a risk threshold score. In Phase 2, a population of 1959 toddler-age children was prospectively screened through multiple pediatric practices in a diverse metropolitan region, using the new instrument. Screen-positive children were referred for diagnostic evaluation. Screened children received follow-up at age 4 years to identify autism cases missed by screening and to specify the scale's psychometric properties. Results: By screening a diverse population of low risk children, age 18 to 36 months, with the PDQ-1, we detected individuals with autism who had not come to professional attention. Overall, the PDQ-1 showed a positive predictive value (PPV) of 88%, with a sensitivity of 85% and specificity of 99% in a low risk population. High specificity, good sensitivity, and PPV were observed across the 18 to 36 month age-range. Conclusion: The findings provide preliminary empirical support for this parent report–based indicator of toddler psychological development and suggest that the PDQ-1 may be a useful supplement to developmental surveillance of autism. Additional research is needed with high risk samples and large, unselected populations under real-world conditions. PMID:29300209

  13. Rapid and sensitive detection of human astrovirus in water samples by loop-mediated isothermal amplification with hydroxynaphthol blue dye

    PubMed Central

    2014-01-01

    Background The aim of this paper was to develop a reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for rapid, sensitive and inexpensive detection of astrovirus. Results The detection limit of LAMP using in vitro RNA transcripts was 3.6×10 copies·μL-1, which is as sensitive as the presently used PCR assays. However, the LAMP products could be identified as different colors with the naked eye following staining with hydroxynaphthol blue dye (HNB). No cross-reactivity with other gastroenteric viruses (rotavirus and norovirus) was observed, indicating the relatively high specificity of LAMP. The RT-LAMP method with HNB was used to effectively detect astrovirus in reclaimed water samples. Conclusions The LAMP technique described in this study is a cheap, sensitive, specific and rapid method for the detection of astrovirus. The RT-LAMP method can be simply applied for the specific detection of astrovirus and has the potential to be utilized in the field as a screening test. PMID:24524254

  14. Multi-test cervical cancer diagnosis with missing data estimation

    NASA Astrophysics Data System (ADS)

    Xu, Tao; Huang, Xiaolei; Kim, Edward; Long, L. Rodney; Antani, Sameer

    2015-03-01

    Cervical cancer is a leading most common type of cancer for women worldwide. Existing screening programs for cervical cancer suffer from low sensitivity. Using images of the cervix (cervigrams) as an aid in detecting pre-cancerous changes to the cervix has good potential to improve sensitivity and help reduce the number of cervical cancer cases. In this paper, we present a method that utilizes multi-modality information extracted from multiple tests of a patient's visit to classify the patient visit to be either low-risk or high-risk. Our algorithm integrates image features and text features to make a diagnosis. We also present two strategies to estimate the missing values in text features: Image Classifier Supervised Mean Imputation (ICSMI) and Image Classifier Supervised Linear Interpolation (ICSLI). We evaluate our method on a large medical dataset and compare it with several alternative approaches. The results show that the proposed method with ICSLI strategy achieves the best result of 83.03% specificity and 76.36% sensitivity. When higher specificity is desired, our method can achieve 90% specificity with 62.12% sensitivity.

  15. Highly sensitive chemiluminescent point mutation detection by circular strand-displacement amplification reaction.

    PubMed

    Shi, Chao; Ge, Yujie; Gu, Hongxi; Ma, Cuiping

    2011-08-15

    Single nucleotide polymorphism (SNP) genotyping is attracting extensive attentions owing to its direct connections with human diseases including cancers. Here, we have developed a highly sensitive chemiluminescence biosensor based on circular strand-displacement amplification and the separation by magnetic beads reducing the background signal for point mutation detection at room temperature. This method took advantage of both the T4 DNA ligase recognizing single-base mismatch with high selectivity and the strand-displacement reaction of polymerase to perform signal amplification. The detection limit of this method was 1.3 × 10(-16)M, which showed better sensitivity than that of most of those reported detection methods of SNP. Additionally, the magnetic beads as carrier of immobility was not only to reduce the background signal, but also may have potential apply in high through-put screening of SNP detection in human genome. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. [Analysis of tools, methods and results of toxicological screening for detection of drug abuse in Italian professional drivers].

    PubMed

    Rosso, G L

    2013-01-01

    Three years after a protocol agreement between the State and the Regions came into force in 2008 (drug testing at the workplace Law) a large number of studies have been conducted to analyse and test the efficacy of on-site screening tests for detection of drug consumption (opiates, cocaine, cannabinoids, amphetamine and methamphetamine, MDMA and methadone), which are frequently used by the occupational health physician, and also to present data resulting from workplace drug testing obtained during health surveillance programmes. The aim of the present study was to verify whether the features of sensitivity and specificity of the most common on-site testing ensure correct application of the provisions of current Italian legislation and also to analyse published studies showing the frequency of positive drug testing. A review of Italian and international literature was carried out aimed at identifying studies relating to: (1) performance of on-site screening tests frequently used by the occupational health physician, (2) prevalence of drug use/abuse among Italian public and commercial transport drivers. A comparison between the studies was then carried out. Several rapid on-site screening tests are commercially available (Italian law does not provide standards for the technical specifications of the tests), the sensitivity and specificity of which varies depending on the model and the substance tested. The sensitivity of these tools is poor when used for the detection of low concentrations of drugs and/or their metabolites in urine (close to the cut-off). Studies are lacking that compare on-site tests performed by the occupational health physician and confirmative tests in specialized laboratories (with particular regard to false positives found by the occupational health physician). The major studies in terms of methods and/or size reported a positive rate (confirmed at the first level) between 1.6% and 1.9%. The drugs most frequently used/abused were cannabis and cocaine. The performance of on-site screening tests (to detect psychotropic substances on urine matrix) and the methodology required by Italian law show that the aims of Italian workplace drug testing legislation have not been achieved The low positive rate observed in Italian studies could be due to an error in the first phase of screening performed by the occupational health physician.

  17. Low sensitivity of implant sonication when screening for infection in revision surgery

    PubMed Central

    Van Diek, Floor M; Albers, Christiaan G M; Van Hooff, Miranda L; Meis, Jacques F; Goosen, Jon H M

    2017-01-01

    Background and purpose Prosthetic-joint infection (PJI) is the most serious complication of arthroplasty, and accurate identification of a potentially responsible microorganism is essential for successful antibiotic treatment. We therefore determined the diagnostic accuracy of sonication and compared it with tissue culture as a screening tool in detecting prosthetic joint infection in revision arthroplasty. Patients and methods 252 consecutive revision arthroplasty cases were enrolled. These cases were determined as being suspected or unsuspected of having infection according to standard criteria. Perioperatively, 6 periprosthetic interface tissue biopsies were obtained from each patient and the implants removed were sonicated. The sensitivity and specificity of periprosthetic tissue culture and sonication fluid cultures were determined. Results Preoperatively, 75 revision cases were classified as having PJI (33 early and 42 late) and 177 were unsuspected of having infection. Compared with tissue culture, the sensitivity of the sonication fluid analysis was low: 0.47 (95% CI: 0.35–0.59) for sonication as compared to 0.68 (95% CI: 0.56–0.78) for tissue culture. The specificity of the sonication fluid analysis was higher than that for tissue culture: 0.99 (95% CI: 0.96–1.0) as compared to 0.80 (95% CI: 0.74–0.86). Interpretation Sonication is a highly specific test for diagnosis of PJI. However, due to the low sensitivity, a negative sonication result does not rule out the presence of PJI. Thus, sonication is not of value for screening of microorganisms during revision surgery. PMID:28287012

  18. Integrated Magneto-Electrochemical Sensor for Exosome Analysis.

    PubMed

    Jeong, Sangmoo; Park, Jongmin; Pathania, Divya; Castro, Cesar M; Weissleder, Ralph; Lee, Hakho

    2016-02-23

    Extracellular vesicles, including exosomes, are nanoscale membrane particles that carry molecular information on parental cells. They are being pursued as biomarkers of cancers that are difficult to detect or serially follow. Here we present a compact sensor technology for rapid, on-site exosome screening. The sensor is based on an integrated magneto-electrochemical assay: exosomes are immunomagnetically captured from patient samples and profiled through electrochemical reaction. By combining magnetic enrichment and enzymatic amplification, the approach enables (i) highly sensitive, cell-specific exosome detection and (ii) sensor miniaturization and scale-up for high-throughput measurements. As a proof-of-concept, we implemented a portable, eight-channel device and applied it to screen extracellular vesicles in plasma samples from ovarian cancer patients. The sensor allowed for the simultaneous profiling of multiple protein markers within an hour, outperforming conventional methods in assay sensitivity and speed.

  19. Integrated Magneto-Electrochemical Sensor for Exosome Analysis

    PubMed Central

    Jeong, Sangmoo; Park, Jongmin; Pathania, Divya; Castro, Cesar M.; Weissleder, Ralph; Lee, Hakho

    2016-01-01

    Extracellular vesicles, including exosomes, are nanoscale vesicles that carry molecular information of parental cells. They are being pursued as biomarkers of cancers that are difficult to detect or serially follow. Here we present a compact sensor technology for rapid, on-site exosome screening. The sensor is based on an integrated magnetic-electrochemical assay: exosomes are immunomagnetically captured from patient samples, and profiled through electrochemical reaction. By combining magnetic enrichment and enzymatic amplification, the approach enables i) highly sensitive, cell-specific exosome detection, and ii) sensor miniaturization and scale-up for high throughput measurements. As a proof-of-concept, we implemented a portable, eight-channel device, and applied it to screen extracellular vesicles in plasma samples from ovarian cancer patients. The sensor allowed for the profiling of multiple protein markers simultaneously within an hour, outperforming conventional methods in assay sensitivity and speed. PMID:26808216

  20. Gram stain method shows better sensitivity than clinical criteria for detection of bacterial vaginosis in surveillance of pregnant, low-income women in a clinical setting.

    PubMed Central

    Tam, M T; Yungbluth, M; Myles, T

    1998-01-01

    OBJECTIVE: The purpose of the study is to determine whether the Gram stain method is superior to the clinical criteria for the diagnosis of bacterial vaginosis in low-income pregnant women seen in a resident clinic setting. The clinical criteria is the current diagnostic method employed to diagnose bacterial vaginosis. STUDY DESIGN: In this study, 51 pregnant women with vaginal discharge were prospectively evaluated. All were screened using the clinical criteria, Gram stain method, and culture of the discharge. The modified scoring system instituted by Nugent et al. (J Clin Microbiol 29:297-301, 1991) was employed in reading the Gram stain smears. The clinical criteria were then compared with the Gram stain method. Isolation of moderate to many Gardnerella vaginalis growth by culture was used as the confirmatory finding. RESULTS: Sensitivity of the Gram stain method (91%) was significantly higher than that of the clinical criteria (46%), (sign test P = 0.0023, < 0.01). The Gram stain method also has both a low false-negative (4%) and high negative predictive value (96%), making it an ideal diagnostic test. CONCLUSION: The Gram stain method is a rapid and cost-effective test that is also highly reproducible and readily available in many laboratories. These features make the Gram stain method a more desirable screening procedure for bacterial vaginosis in a clinic population. PMID:9894174

  1. Can we rely on the multiplex ligation-dependent probe amplification method (MLPA) for prenatal diagnosis?

    PubMed Central

    Omrani, Mir Davood; Azizi, Faezeh; Rajabibazl, Masoumeh; Safavi Naini, Niloufar; Omrani, Sara; Abbasi, Arezo Mona; Saleh Gargari, Soraya

    2014-01-01

    Background: The major aneuploidies that are diagnosed prenatally involve the autosomal chromosomes 13, 18, and 21, as well as sex chromosomes, X and Y. Because multiplex ligation-dependent probe amplification (MLPA) is rapid and non-invasive, it has replaced traditional culture methods for the screening and diagnosis of common aneuploidies in some countries. Objective: To evaluate the sensitivity and specificity of MLPA in a cross-sectional descriptive study for the detection of chromosomal aneuploidies in comparison to other methods. Materials and Methods: Genomic DNA was extracted from the peripheral blood samples of 10 normal controls and the amniotic fluid of 55 patients. Aneuploidies screening of chromosomes 13, 18, 21, X and Y were carried out using specific MLPA probe mixes (P095-A2). For comparison purposes, samples were also tested by Quantitative Fluorescent-PCR (QF-PCR) and routine chromosomal culture method. Results: Using this specific MLPA technique and data-analyzing software (Genemarker v1.85), one case was diagnosed with 45, X (e.g. Monosomy X or Turner’s Syndrome), and the remaining 54 cases revealed normal karyotypes. These results were concordant with routine chromosomal culture and QF-PCR findings. Conclusion: The experiment demonstrates that MLPA can provide a rapid and accurate clinical method for prenatal identification of common chromosomal aneuploidies with 100% sensitivity and 100% specificity. PMID:24976821

  2. Real-time and online screening method for materials emitting volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Kim, Changhyuk; Sul, Yong Tae; Pui, David Y. H.

    2016-09-01

    In the semiconductor industry, volatile organic compounds (VOCs) in the cleanroom air work as airborne molecular contamination, which reduce the production yield of semiconductor chips by forming nanoparticles and haze on silicon wafers and photomasks under ultraviolet irradiation during photolithography processes. Even though VOCs in outdoor air are removed by gas filters, VOCs can be emitted from many kinds of materials used in cleanrooms, such as organic solvents and construction materials (e.g., adhesives, flame retardants and sealants), threatening the production of semiconductors. Therefore, finding new replacements that emit lower VOCs is now essential in the semiconductor industry. In this study, we developed a real-time and online method to screen materials for developing the replacements by converting VOCs into nanoparticles under soft X-ray irradiation. This screening method was applied to measure VOCs emitted from different kinds of organic solvents and adhesives. Our results showed good repeatability and high sensitivity for VOCs, which come from aromatic compounds, some alcohols and all tested adhesives (Super glue and cleanroom-use adhesives). In addition, the overall trend of measured VOCs from cleanroom-use adhesives was well matched with those measured by a commercial thermal desorption-gas chromatography-mass spectrometry, which is a widely used off-line method for analyzing VOCs. Based on the results, this screening method can help accelerate the developing process for reducing VOCs in cleanrooms.

  3. Quantitative influence of risk factors on blood glucose level.

    PubMed

    Chen, Songjing; Luo, Senlin; Pan, Limin; Zhang, Tiemei; Han, Longfei; Zhao, Haixiu

    2014-01-01

    The aim of this study is to quantitatively analyze the influence of risk factors on the blood glucose level, and to provide theory basis for understanding the characteristics of blood glucose change and confirming the intervention index for type 2 diabetes. The quantitative method is proposed to analyze the influence of risk factors on blood glucose using back propagation (BP) neural network. Ten risk factors are screened first. Then the cohort is divided into nine groups by gender and age. According to the minimum error principle, nine BP models are trained respectively. The quantitative values of the influence of different risk factors on the blood glucose change can be obtained by sensitivity calculation. The experiment results indicate that weight is the leading cause of blood glucose change (0.2449). The second factors are cholesterol, age and triglyceride. The total ratio of these four factors reaches to 77% of the nine screened risk factors. And the sensitivity sequences can provide judgment method for individual intervention. This method can be applied to risk factors quantitative analysis of other diseases and potentially used for clinical practitioners to identify high risk populations for type 2 diabetes as well as other disease.

  4. Optimization of information content in a mass spectrometry based flow-chemistry system by investigating different ionization approaches.

    PubMed

    Martha, Cornelius T; Hoogendoorn, Jan-Carel; Irth, Hubertus; Niessen, Wilfried M A

    2011-05-15

    Current development in catalyst discovery includes combinatorial synthesis methods for the rapid generation of compound libraries combined with high-throughput performance-screening methods to determine the associated activities. Of these novel methodologies, mass spectrometry (MS) based flow chemistry methods are especially attractive due to the ability to combine sensitive detection of the formed reaction product with identification of introduced catalyst complexes. Recently, such a mass spectrometry based continuous-flow reaction detection system was utilized to screen silver-adducted ferrocenyl bidentate catalyst complexes for activity in a multicomponent synthesis of a substituted 2-imidazoline. Here, we determine the merits of different ionization approaches by studying the combination of sensitive detection of product formation in the continuous-flow system with the ability to simultaneous characterize the introduced [ferrocenyl bidentate+Ag](+) catalyst complexes. To this end, we study the ionization characteristics of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), no-discharge APCI, dual ESI/APCI, and dual APCI/no-discharge APCI. Finally, we investigated the application potential of the different ionization approaches by the investigation of ferrocenyl bidentate catalyst complex responses in different solvents. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Node-pore sensing enables label-free surface-marker profiling of single cells.

    PubMed

    Balakrishnan, Karthik R; Whang, Jeremy C; Hwang, Richard; Hack, James H; Godley, Lucy A; Sohn, Lydia L

    2015-03-03

    Flow cytometry is a ubiquitous, multiparametric method for characterizing cellular populations. However, this method can grow increasingly complex with the number of proteins that need to be screened simultaneously: spectral emission overlap of fluorophores and the subsequent need for compensation, lengthy sample preparation, and multiple control tests that need to be performed separately must all be considered. These factors lead to increased costs, and consequently, flow cytometry is performed in core facilities with a dedicated technician operating the instrument. Here, we describe a low-cost, label-free microfluidic method that can determine the phenotypic profiles of single cells. Our method employs Node-Pore Sensing to measure the transit times of cells as they interact with a series of different antibodies, each corresponding to a specific cell-surface antigen, that have been functionalized in a single microfluidic channel. We demonstrate the capabilities of our method not only by screening two acute promyelocytic leukemia human cells lines (NB4 and AP-1060) for myeloid antigens, CD13, CD14, CD15, and CD33, simultaneously, but also by distinguishing a mixture of cells of similar size—AP-1060 and NALM-1—based on surface markers CD13 and HLA-DR. Furthermore, we show that our method can screen complex subpopulations in clinical samples: we successfully identified the blast population in primary human bone marrow samples from patients with acute myeloid leukemia and screened these cells for CD13, CD34, and HLA-DR. We show that our label-free method is an affordable, highly sensitive, and user-friendly technology that has the potential to transform cellular screening at the benchside.

  6. Cost effectiveness analysis of screening for sight threatening diabetic eye disease

    PubMed Central

    James, Marilyn; Turner, David A; Broadbent, Deborah M; Vora, Jiten; Harding, Simon P

    2000-01-01

    Objective To measure the cost effectiveness of systematic photographic screening for sight threatening diabetic eye disease compared with existing practice. Design Cost effectiveness analysis Setting Liverpool. Subjects A target population of 5000 diabetic patients invited for screening. Main outcome measures Cost effectiveness (cost per true positive) of systematic and opportunistic programmes; incremental cost effectiveness of replacing opportunistic with systematic screening. Results Baseline prevalence of sight threatening eye disease was 14.1%. The cost effectiveness of the systematic programme was £209 (sensitivity 89%, specificity 86%, compliance 80%, annual cost £104 996) and of the opportunistic programme was £289 (combined sensitivity 63%, specificity 92%, compliance 78%, annual cost £99 981). The incremental cost effectiveness of completely replacing the opportunistic programme was £32. Absolute values of cost effectiveness were highly sensitive to varying prevalence, sensitivity and specificity, compliance, and programme size. Conclusion Replacing existing programmes with systematic screening for diabetic eye disease is justified. PMID:10856062

  7. Receiver operating characteristic analysis of prediction for gastric cancer development using serum pepsinogen and Helicobacter pylori antibody tests.

    PubMed

    Hamashima, Chisato; Sasazuki, Shizuka; Inoue, Manami; Tsugane, Shoichiro

    2017-03-09

    Chronic Helicobacter pylori infection plays a central role in the development of gastric cancer as shown by biological and epidemiological studies. The H. pylori antibody and serum pepsinogen (PG) tests have been anticipated to predict gastric cancer development. We determined the predictive sensitivity and specificity of gastric cancer development using these tests. Receiver operating characteristic analysis was performed, and areas under the curve were estimated. The predictive sensitivity and specificity of gastric cancer development were compared among single tests and combined methods using serum pepsinogen and H. pylori antibody tests. From a large-scale population-based cohort of over 100,000 subjects followed between 1990 and 2004, 497 gastric cancer subjects and 497 matched healthy controls were chosen. The predictive sensitivity and specificity were low in all single tests and combination methods. The highest predictive sensitivity and specificity were obtained for the serum PG I/II ratio. The optimal PG I/II cut-off values were 2.5 and 3.0. At a PG I/II cut-off value of 3.0, the sensitivity was 86.9% and the specificity was 39.8%. Even if three biomarkers were combined, the sensitivity was 97.2% and the specificity was 21.1% when the cut-off values were 3.0 for PG I/II, 70 ng/mL for PG I, and 10.0 U/mL for H. pylori antibody. The predictive accuracy of gastric cancer development was low with the serum pepsinogen and H. pylori antibody tests even if these tests were combined. To adopt these biomarkers for gastric cancer screening, a high specificity is required. When these tests are adopted for gastric cancer screening, they should be carefully interpreted with a clear understanding of their limitations.

  8. Noninvasive High-Throughput Single-Cell Analysis of HIV Protease Activity Using Ratiometric Flow Cytometry

    PubMed Central

    Gaber, Rok; Majerle, Andreja; Jerala, Roman; Benčina, Mojca

    2013-01-01

    To effectively fight against the human immunodeficiency virus infection/acquired immunodeficiency syndrome (HIV/AIDS) epidemic, ongoing development of novel HIV protease inhibitors is required. Inexpensive high-throughput screening assays are needed to quickly scan large sets of chemicals for potential inhibitors. We have developed a Förster resonance energy transfer (FRET)-based, HIV protease-sensitive sensor using a combination of a fluorescent protein pair, namely mCerulean and mCitrine. Through extensive in vitro characterization, we show that the FRET-HIV sensor can be used in HIV protease screening assays. Furthermore, we have used the FRET-HIV sensor for intracellular quantitative detection of HIV protease activity in living cells, which more closely resembles an actual viral infection than an in vitro assay. We have developed a high-throughput method that employs a ratiometric flow cytometry for analyzing large populations of cells that express the FRET-HIV sensor. The method enables FRET measurement of single cells with high sensitivity and speed and should be used when subpopulation-specific intracellular activity of HIV protease needs to be estimated. In addition, we have used a confocal microscopy sensitized emission FRET technique to evaluate the usefulness of the FRET-HIV sensor for spatiotemporal detection of intracellular HIV protease activity. PMID:24287545

  9. Specific guidelines for assessing and improving the methodological quality of economic evaluations of newborn screening

    PubMed Central

    2012-01-01

    Background Economic evaluation of newborn screening poses specific methodological challenges. Amongst others, these challenges refer to the use of quality adjusted life years (QALYs) in newborns, and which costs and outcomes need to be considered in a full evaluation of newborn screening programmes. Because of the increasing scale and scope of such programmes, a better understanding of the methods of high-quality economic evaluations may be crucial for both producers/authors and consumers/reviewers of newborn screening-related economic evaluations. The aim of this study was therefore to develop specific guidelines designed to assess and improve the methodological quality of economic evaluations in newborn screening. Methods To develop the guidelines, existing guidelines for assessing the quality of economic evaluations were identified through a literature search, and were reviewed and consolidated using a deductive iterative approach. In a subsequent test phase, these guidelines were applied to various economic evaluations which acted as case studies. Results The guidelines for assessing and improving the methodological quality of economic evaluations in newborn screening are organized into 11 categories: “bibliographic details”, “study question and design”, “modelling”, “health outcomes”, “costs”, “discounting”, “presentation of results”, “sensitivity analyses”, “discussion”, “conclusions”, and “commentary”. Conclusions The application of the guidelines highlights important issues regarding newborn screening-related economic evaluations, and underscores the need for such issues to be afforded greater consideration in future economic evaluations. The variety in methodological quality detected by this study reveals the need for specific guidelines on the appropriate methods for conducting sound economic evaluations in newborn screening. PMID:22947299

  10. Hair-based rapid analyses for multiple drugs in forensics and doping: application of dynamic multiple reaction monitoring with LC-MS/MS.

    PubMed

    Shah, Iltaf; Petroczi, Andrea; Uvacsek, Martina; Ránky, Márta; Naughton, Declan P

    2014-01-01

    Considerable efforts are being extended to develop more effective methods to detect drugs in forensic science for applications such as preventing doping in sport. The aim of this study was to develop a sensitive and accurate method for analytes of forensic and toxicological nature in human hair at sub-pg levels. The hair test covers a range of different classes of drugs and metabolites of forensic and toxicological nature including selected anabolic steroids, cocaine, amphetamines, cannabinoids, opiates, bronchodilators, phencyclidine and ketamine. For extraction purposes, the hair samples were decontaminated using dichloromethane, ground and treated with 1 M sodium hydroxide and neutralised with hydrochloric acid and phosphate buffer and the homogenate was later extracted with hexane using liquid-liquid extraction (LLE). Following extraction from hair samples, drug-screening employed liquid chromatography coupled to tandem mass spectrometric (LC-MS/MS) analysis using dynamic multiple reaction monitoring (DYN-MRM) method using proprietary software. The screening method (for > 200 drugs/metabolites) was calibrated with a tailored drug mixture and was validated for 20 selected drugs for this study. Using standard additions to hair sample extracts, validation was in line with FDA guidance. A Zorbax Eclipse plus C18 (2.1 mm internal diameter × 100 mm length × 1.8 μm particle size) column was used for analysis. Total instrument run time was 8 minutes with no noted matrix interferences. The LOD of compounds ranged between 0.05-0.5 pg/mg of hair. 233 human hair samples were screened using this new method and samples were confirmed positive for 20 different drugs, mainly steroids and drugs of abuse. This is the first report of the application of this proprietary system to investigate the presence of drugs in human hair samples. The method is selective, sensitive and robust for the screening and confirmation of multiple drugs in a single analysis and has potential as a very useful tool for the analysis of large array of controlled substances and drugs of abuse.

  11. Noninvasive chromosome screening of human embryos by genome sequencing of embryo culture medium for in vitro fertilization.

    PubMed

    Xu, Juanjuan; Fang, Rui; Chen, Li; Chen, Daozhen; Xiao, Jian-Ping; Yang, Weimin; Wang, Honghua; Song, Xiaoqing; Ma, Ting; Bo, Shiping; Shi, Chong; Ren, Jun; Huang, Lei; Cai, Li-Yi; Yao, Bing; Xie, X Sunney; Lu, Sijia

    2016-10-18

    Preimplantation genetic screening (PGS) is widely used to select in vitro-fertilized embryos free of chromosomal abnormalities and to improve the clinical outcome of in vitro fertilization (IVF). A disadvantage of PGS is that it requires biopsy of the preimplantation human embryo, which can limit the clinical applicability of PGS due to the invasiveness and complexity of the process. Here, we present and validate a noninvasive chromosome screening (NICS) method based on sequencing the genomic DNA secreted into the culture medium from the human blastocyst. By using multiple annealing and looping-based amplification cycles (MALBAC) for whole-genome amplification (WGA), we performed next-generation sequencing (NGS) on the spent culture medium used to culture human blastocysts (n = 42) and obtained the ploidy information of all 24 chromosomes. We validated these results by comparing each with their corresponding whole donated embryo and obtained a high correlation for identification of chromosomal abnormalities (sensitivity, 0.882, and specificity, 0.840). With this validated NICS method, we performed chromosome screening on IVF embryos from seven couples with balanced translocation, azoospermia, or recurrent pregnancy loss. Six of them achieved successful clinical pregnancies, and five have already achieved healthy live births thus far. The NICS method avoids the need for embryo biopsy and therefore substantially increases the safety of its use. The method has the potential of much wider chromosome screening applicability in clinical IVF, due to its high accuracy and noninvasiveness.

  12. Assessing emotional well-being of children in a Honduran orphanage: feasibility of two screening tools.

    PubMed

    Debiasi, Laura B; Reynolds, Annette; Buckner, Ellen B

    2012-01-01

    The World Health Organization (WHO) has determined mental health in children to be a priority area for evidence-based interventions. Effective and efficient screening methods are needed to assess emotional well-being of children from diverse cultures. This descriptive study examined two tools for feasibility, sensitivity, cultural appropriateness, and cost/time effectiveness. Emotional well-being was conceptualized using the Roy Adaptation Model as part of the self-concept adaptive mode. Emotional indicators were measured from Human Figure Drawings. Anxiety was measured using a modification of the Revised Children's Manifest Anxiety Survey (RCMAS). The sample included 11 girls who were 7 to 12 years of age and recruited from a girls' orphanage in Honduras. Results indicated the Human Figure Drawings identified more children possibly at risk than the RCMAS. Human Figure Drawings were found to be a time/cost-effective, sensitive, and culturally appropriate means for measuring emotional well-being in the setting. This study contributes to nursing knowledge by demonstrating feasibility of the screening tools for measuring emotional well-being of children in varied cultures.

  13. Posttraumatic stress disorder in veterans and military personnel: epidemiology, screening, and case recognition.

    PubMed

    Gates, Margaret A; Holowka, Darren W; Vasterling, Jennifer J; Keane, Terence M; Marx, Brian P; Rosen, Raymond C

    2012-11-01

    Posttraumatic stress disorder (PTSD) is a psychiatric disorder that affects 7-8% of the general U.S. population at some point during their lifetime; however, the prevalence is much higher among certain subgroups, including active duty military personnel and veterans. In this article, we review the empirical literature on the epidemiology and screening of PTSD in military and veteran populations, including the availability of sensitive and reliable screening tools. Although estimates vary across studies, evidence suggests that the prevalence of PTSD in deployed U.S. military personnel may be as high as 14-16%. Prior studies have identified trauma characteristics and pre- and posttrauma factors that increase risk of PTSD among veterans and military personnel. This information may help to inform prevention and screening efforts, as screening programs could be targeted to high-risk populations. Large-scale screening efforts have recently been implemented by the U.S. Departments of Defense and Veterans Affairs. Given the prevalence and potential consequences of PTSD among veterans and active duty military personnel, development and continued evaluation of effective screening methods is an important public health need.

  14. Comprehensive Mechanistic Analysis of Hits from High-Throughput and Docking Screens against β-Lactamase

    PubMed Central

    Babaoglu, Kerim; Simeonov, Anton; Irwin, John J.; Nelson, Michael E.; Feng, Brian; Thomas, Craig J.; Cancian, Laura; Costi, M. Paola; Maltby, David A.; Jadhav, Ajit; Inglese, James; Austin, Christopher P.; Shoichet, Brian K.

    2009-01-01

    High-throughput screening (HTS) is widely used in drug discovery. Especially for screens of unbiased libraries, false positives can dominate “hit lists”; their origins are much debated. Here we determine the mechanism of every active hit from a screen of 70,563 unbiased molecules against β-lactamase using quantitative HTS (qHTS). Of the 1274 initial inhibitors, 95% were detergent-sensitive and were classified as aggregators. Among the 70 remaining were 25 potent, covalent-acting β-lactams. Mass spectra, counter-screens, and crystallography identified 12 as promiscuous covalent inhibitors. The remaining 33 were either aggregators or irreproducible. No specific reversible inhibitors were found. We turned to molecular docking to prioritize molecules from the same library for testing at higher concentrations. Of 16 tested, 2 were modest inhibitors. Subsequent X-ray structures corresponded to the docking prediction. Analog synthesis improved affinity to 8 µM. These results suggest that it may be the physical behavior of organic molecules, not their reactivity, that accounts for most screening artifacts. Structure-based methods may prioritize weak-but-novel chemotypes in unbiased library screens. PMID:18333608

  15. Cervical screening and the aftermath of childhood sexual abuse: are clinical staff trained to recognise and manage the effect this has on their patients?

    PubMed

    Walker, Judith; Allan, Helen T

    2014-07-01

    To evaluate the training needs and awareness of childhood sexual abuse amongst clinical staff taking cervical screening samples in one inner city primary care trust. Studies exploring sexual abuse and nonparticipation in cervical screening have demonstrated that women can experience re-traumatisation if care during examinations is insensitive to their particular needs. This was a mixed methods, service evaluation in three phases. A literature review, a questionnaire to cervical screening staff in an inner city primary care trust and a focus group of four staff drawn from questionnaire respondents to explore themes raised in the questionnaire data. Data analysis of both quantitative and qualitative data showed that clinical staff underestimated the frequency of childhood sexual abuse although they were aware of the difficulties and reluctance some women experience undergoing gynaecological examinations. When women did disclose childhood sexual abuse or when staff suspected a history of childhood sexual abuse, staff reported feeling unsure of how they should proceed. There was no support or clinical supervision, and unmet training needs were identified. Nurses expressed anxiety around the potential of the screening test to cause more harm than good and at their inability to provide more help than listening. Staff wanted support and further training after completing their cervical screening training course to assist in their provision of sensitive care to patients who have experienced childhood sexual abuse. Whilst our results cannot be generalised to a wider population, they may be meaningful for the community of cervical screening takers. We argue that screening staff require further training and professional support (clinical supervision) to increase their confidence when providing safe and sensitive practice for childhood sexual abuse survivors. If staff feel more confident and competent when responding to disclosure of childhood sexual abuse in screening situations, women who have experienced childhood sexual abuse might participate in the screening programme more readily. © 2013 John Wiley & Sons Ltd.

  16. Fast detection and characterization of organic and inorganic gunshot residues on the hands of suspects by CMV-GC-MS and LIBS.

    PubMed

    Tarifa, Anamary; Almirall, José R

    2015-05-01

    A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  17. Sensitivity and Specificity of 2 Autism Screeners Among Referred Children Between 16 and 48 Months of Age.

    PubMed

    Salisbury, Louisa A; Nyce, Jonathan D; Hannum, Charles D; Sheldrick, R Christopher; Perrin, Ellen C

    2018-04-01

    Autism screening is recommended by the American Academy of Pediatrics and the Centers for Disease Control and Prevention at ages 18 and 24 months. Popular screening tests have been validated for the age range of 16 to 30 months. However, only a minority of children with autism spectrum disorder (ASD) are identified by age 3 years, and many are not identified until after they enter school. Thus, we aimed to measure the sensitivity and specificity of 2 available screening tests for ASDs in children older than 30 months. We assessed the sensitivity and specificity of 2 ASD screening tools administered to parents of children who were referred to a developmental clinic between the ages of 16 and 48 months: the Modified Checklist for Autism in Toddlers (M-CHAT) and the Parent's Observations of Social Interactions (POSI), which is a component of a comprehensive screening instrument called, the Survey of Well-being of Young Children. Both the M-CHAT and the POSI had acceptable sensitivity (≥75%) among children across the age range studied. Their specificity was limited by the fact that the study was conducted in a developmental referral clinic. Two readily available screening tools, the POSI and the M-CHAT, have acceptable sensitivity in evaluating risk for autism in children at least to age 48 months. Further research should investigate their sensitivity and specificity when used in primary care settings.

  18. QSPR studies on the photoinduced-fluorescence behaviour of pharmaceuticals and pesticides.

    PubMed

    López-Malo, D; Bueso-Bordils, J I; Duart, M J; Alemán-López, P A; Martín-Algarra, R V; Antón-Fos, G M; Lahuerta-Zamora, L; Martínez-Calatayud, J

    2017-07-01

    Fluorimetric analysis is still a growing line of research in the determination of a wide range of organic compounds, including pharmaceuticals and pesticides, which makes necessary the development of new strategies aimed at improving the performance of fluorescence determinations as well as the sensitivity and, especially, the selectivity of the newly developed analytical methods. In this paper are presented applications of a useful and growing tool suitable for fostering and improving research in the analytical field. Experimental screening, molecular connectivity and discriminant analysis are applied to organic compounds to predict their fluorescent behaviour after their photodegradation by UV irradiation in a continuous flow manifold (multicommutation flow assembly). The screening was based on online fluorimetric measurement and comprised pre-selected compounds with different molecular structures (pharmaceuticals and some pesticides with known 'native' fluorescent behaviour) to study their changes in fluorescent behaviour after UV irradiation. Theoretical predictions agree with the results from the experimental screening and could be used to develop selective analytical methods, as well as helping to reduce the need for expensive, time-consuming and trial-and-error screening procedures.

  19. Modeling Test and Treatment Strategies for Presymptomatic Alzheimer Disease

    PubMed Central

    Burke, James F.; Langa, Kenneth M.; Hayward, Rodney A.; Albin, Roger L.

    2014-01-01

    Objectives In this study, we developed a model of presymptomatic treatment of Alzheimer disease (AD) after a screening diagnostic evaluation and explored the circumstances required for an AD prevention treatment to produce aggregate net population benefit. Methods Monte Carlo simulation methods were used to estimate outcomes in a simulated population derived from data on AD incidence and mortality. A wide variety of treatment parameters were explored. Net population benefit was estimated in aggregated QALYs. Sensitivity analyses were performed by individually varying the primary parameters. Findings In the base-case scenario, treatment effects were uniformly positive, and net benefits increased with increasing age at screening. A highly efficacious treatment (i.e. relative risk 0.6) modeled in the base-case is estimated to save 20 QALYs per 1000 patients screened and 221 QALYs per 1000 patients treated. Conclusions Highly efficacious presymptomatic screen and treat strategies for AD are likely to produce substantial aggregate population benefits that are likely greater than the benefits of aspirin in primary prevention of moderate risk cardiovascular disease (28 QALYS per 1000 patients treated), even in the context of an imperfect treatment delivery environment. PMID:25474698

  20. Screening HIV-Infected Patients with Low CD4 Counts for Cryptococcal Antigenemia prior to Initiation of Antiretroviral Therapy: Cost Effectiveness of Alternative Screening Strategies in South Africa

    PubMed Central

    Rockers, Peter C.; Bonawitz, Rachael; Sriruttan, Charlotte; Glencross, Deborah K.; Cassim, Naseem; Coetzee, Lindi M.; Greene, Gregory S.; Chiller, Tom M.; Vallabhaneni, Snigdha; Long, Lawrence; van Rensburg, Craig; Govender, Nelesh P.

    2016-01-01

    Background In 2015 South Africa established a national cryptococcal antigenemia (CrAg) screening policy targeted at HIV-infected patients with CD4+ T-lymphocyte (CD4) counts <100 cells/ μl who are not yet on antiretroviral treatment (ART). Two screening strategies are included in national guidelines: reflex screening, where a CrAg test is performed on remnant blood samples from CD4 testing; and provider-initiated screening, where providers order a CrAg test after a patient returns for CD4 test results. The objective of this study was to compare costs and effectiveness of these two screening strategies. Methods We developed a decision analytic model to compare reflex and provider-initiated screening in terms of programmatic and health outcomes (number screened, number identified for preemptive treatment, lives saved, and discounted years of life saved) and screening and treatment costs (2015 USD). We estimated a base case with prevalence and other parameters based on data collected during CrAg screening pilot projects integrated into routine HIV care in Gauteng, Free State, and Western Cape Provinces. We conducted sensitivity analyses to explore how results change with underlying parameter assumptions. Results In the base case, for each 100,000 CD4 tests, the reflex strategy compared to the provider-initiated strategy has higher screening costs ($37,536 higher) but lower treatment costs ($55,165 lower), so overall costs of screening and treatment are $17,629 less with the reflex strategy. The reflex strategy saves more lives (30 lives, 647 additional years of life saved). Sensitivity analyses suggest that reflex screening dominates provider-initiated screening (lower total costs and more lives saved) or saves additional lives for small additional costs (< $125 per life year) across a wide range of conditions (CrAg prevalence, patient and provider behavior, patient survival without treatment, and effectiveness of preemptive fluconazole treatment). Conclusions In countries with substantial numbers of people with untreated, advanced HIV disease such as South Africa, CrAg screening before initiation of ART has the potential to reduce cryptococcal meningitis and save lives. Reflex screening compared to provider-initiated screening saves more lives and is likely to be cost saving or have low additional costs per additional year of life saved. PMID:27390864

Top