Sample records for sensitivity analysis determined

  1. Thermodynamic modeling of transcription: sensitivity analysis differentiates biological mechanism from mathematical model-induced effects.

    PubMed

    Dresch, Jacqueline M; Liu, Xiaozhou; Arnosti, David N; Ay, Ahmet

    2010-10-24

    Quantitative models of gene expression generate parameter values that can shed light on biological features such as transcription factor activity, cooperativity, and local effects of repressors. An important element in such investigations is sensitivity analysis, which determines how strongly a model's output reacts to variations in parameter values. Parameters of low sensitivity may not be accurately estimated, leading to unwarranted conclusions. Low sensitivity may reflect the nature of the biological data, or it may be a result of the model structure. Here, we focus on the analysis of thermodynamic models, which have been used extensively to analyze gene transcription. Extracted parameter values have been interpreted biologically, but until now little attention has been given to parameter sensitivity in this context. We apply local and global sensitivity analyses to two recent transcriptional models to determine the sensitivity of individual parameters. We show that in one case, values for repressor efficiencies are very sensitive, while values for protein cooperativities are not, and provide insights on why these differential sensitivities stem from both biological effects and the structure of the applied models. In a second case, we demonstrate that parameters that were thought to prove the system's dependence on activator-activator cooperativity are relatively insensitive. We show that there are numerous parameter sets that do not satisfy the relationships proferred as the optimal solutions, indicating that structural differences between the two types of transcriptional enhancers analyzed may not be as simple as altered activator cooperativity. Our results emphasize the need for sensitivity analysis to examine model construction and forms of biological data used for modeling transcriptional processes, in order to determine the significance of estimated parameter values for thermodynamic models. Knowledge of parameter sensitivities can provide the necessary context to determine how modeling results should be interpreted in biological systems.

  2. Improving the sensitivity and accuracy of gamma activation analysis for the rapid determination of gold in mineral ores.

    PubMed

    Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel

    2017-04-01

    Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.

  3. Statistical sensitivity analysis of a simple nuclear waste repository model

    NASA Astrophysics Data System (ADS)

    Ronen, Y.; Lucius, J. L.; Blow, E. M.

    1980-06-01

    A preliminary step in a comprehensive sensitivity analysis of the modeling of a nuclear waste repository. The purpose of the complete analysis is to determine which modeling parameters and physical data are most important in determining key design performance criteria and then to obtain the uncertainty in the design for safety considerations. The theory for a statistical screening design methodology is developed for later use in the overall program. The theory was applied to the test case of determining the relative importance of the sensitivity of near field temperature distribution in a single level salt repository to modeling parameters. The exact values of the sensitivities to these physical and modeling parameters were then obtained using direct methods of recalculation. The sensitivity coefficients found to be important for the sample problem were thermal loading, distance between the spent fuel canisters and their radius. Other important parameters were those related to salt properties at a point of interest in the repository.

  4. Analysis of the sensitivity properties of a model of vector-borne bubonic plague.

    PubMed

    Buzby, Megan; Neckels, David; Antolin, Michael F; Estep, Donald

    2008-09-06

    Model sensitivity is a key to evaluation of mathematical models in ecology and evolution, especially in complex models with numerous parameters. In this paper, we use some recently developed methods for sensitivity analysis to study the parameter sensitivity of a model of vector-borne bubonic plague in a rodent population proposed by Keeling & Gilligan. The new sensitivity tools are based on a variational analysis involving the adjoint equation. The new approach provides a relatively inexpensive way to obtain derivative information about model output with respect to parameters. We use this approach to determine the sensitivity of a quantity of interest (the force of infection from rats and their fleas to humans) to various model parameters, determine a region over which linearization at a specific parameter reference point is valid, develop a global picture of the output surface, and search for maxima and minima in a given region in the parameter space.

  5. An initial investigation into methods of computing transonic aerodynamic sensitivity coefficients

    NASA Technical Reports Server (NTRS)

    Carlson, Leland A.

    1991-01-01

    The three dimensional quasi-analytical sensitivity analysis and the ancillary driver programs are developed needed to carry out the studies and perform comparisons. The code is essentially contained in one unified package which includes the following: (1) a three dimensional transonic wing analysis program (ZEBRA); (2) a quasi-analytical portion which determines the matrix elements in the quasi-analytical equations; (3) a method for computing the sensitivity coefficients from the resulting quasi-analytical equations; (4) a package to determine for comparison purposes sensitivity coefficients via the finite difference approach; and (5) a graphics package.

  6. USE OF SENSITIVITY ANALYSIS ON A PHYSIOLOGICALLY-BASED PHARMACOKINETIC (PBPK) MODEL FOR CHLOROFORM IN RATS TO DETERMINE AGE-RELATED TOXICITY

    EPA Science Inventory

    USE OF SENSITIVITY ANALYSIS ON A PHYSIOLOGICALLY BASED PHARMACOKINETIC (PBPK) MODEL FOR CHLOROFORM IN RATS TO DETERMINE AGE-RELATED TOXICITY.
    CR Eklund, MV Evans, and JE Simmons. US EPA, ORD, NHEERL, ETD,PKB, Research Triangle Park, NC.

    Chloroform (CHCl3) is a disinfec...

  7. Analysis of sensitivity and uncertainty in an individual-based model of a threatened wildlife species

    Treesearch

    Bruce G. Marcot; Peter H. Singleton; Nathan H. Schumaker

    2015-01-01

    Sensitivity analysis—determination of how prediction variables affect response variables—of individual-based models (IBMs) are few but important to the interpretation of model output. We present sensitivity analysis of a spatially explicit IBM (HexSim) of a threatened species, the Northern Spotted Owl (NSO; Strix occidentalis caurina) in Washington...

  8. Sensitivity analysis of Jacobian determinant used in treatment planning for lung cancer

    NASA Astrophysics Data System (ADS)

    Shao, Wei; Gerard, Sarah E.; Pan, Yue; Patton, Taylor J.; Reinhardt, Joseph M.; Durumeric, Oguz C.; Bayouth, John E.; Christensen, Gary E.

    2018-03-01

    Four-dimensional computed tomography (4DCT) is regularly used to visualize tumor motion in radiation therapy for lung cancer. These 4DCT images can be analyzed to estimate local ventilation by finding a dense correspondence map between the end inhalation and the end exhalation CT image volumes using deformable image registration. Lung regions with ventilation values above a threshold are labeled as regions of high pulmonary function and are avoided when possible in the radiation plan. This paper investigates a sensitivity analysis of the relative Jacobian error to small registration errors. We present a linear approximation of the relative Jacobian error. Next, we give a formula for the sensitivity of the relative Jacobian error with respect to the Jacobian of perturbation displacement field. Preliminary sensitivity analysis results are presented using 4DCT scans from 10 individuals. For each subject, we generated 6400 random smooth biologically plausible perturbation vector fields using a cubic B-spline model. We showed that the correlation between the Jacobian determinant and the Frobenius norm of the sensitivity matrix is close to -1, which implies that the relative Jacobian error in high-functional regions is less sensitive to noise. We also showed that small displacement errors on the average of 0.53 mm may lead to a 10% relative change in Jacobian determinant. We finally showed that the average relative Jacobian error and the sensitivity of the system for all subjects are positively correlated (close to +1), i.e. regions with high sensitivity has more error in Jacobian determinant on average.

  9. Boundary formulations for sensitivity analysis without matrix derivatives

    NASA Technical Reports Server (NTRS)

    Kane, J. H.; Guru Prasad, K.

    1993-01-01

    A new hybrid approach to continuum structural shape sensitivity analysis employing boundary element analysis (BEA) is presented. The approach uses iterative reanalysis to obviate the need to factor perturbed matrices in the determination of surface displacement and traction sensitivities via a univariate perturbation/finite difference (UPFD) step. The UPFD approach makes it possible to immediately reuse existing subroutines for computation of BEA matrix coefficients in the design sensitivity analysis process. The reanalysis technique computes economical response of univariately perturbed models without factoring perturbed matrices. The approach provides substantial computational economy without the burden of a large-scale reprogramming effort.

  10. Fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics.

    PubMed

    Pujol-Vila, F; Vigués, N; Díaz-González, M; Muñoz-Berbel, X; Mas, J

    2015-05-15

    Global urban and industrial growth, with the associated environmental contamination, is promoting the development of rapid and inexpensive general toxicity methods. Current microbial methodologies for general toxicity determination rely on either bioluminescent bacteria and specific medium solution (i.e. Microtox(®)) or low sensitivity and diffusion limited protocols (i.e. amperometric microbial respirometry). In this work, fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics is presented, using Escherichia coli as a bacterial model. Ferricyanide reduction kinetic analysis (variation of ferricyanide absorption with time), much more sensitive than single absorbance measurements, allowed for direct and fast toxicity determination without pre-incubation steps (assay time=10 min) and minimizing biomass interference. Dual wavelength analysis at 405 (ferricyanide and biomass) and 550 nm (biomass), allowed for ferricyanide monitoring without interference of biomass scattering. On the other hand, refractive index (RI) matching with saccharose reduced bacterial light scattering around 50%, expanding the analytical linear range in the determination of absorbent molecules. With this method, different toxicants such as metals and organic compounds were analyzed with good sensitivities. Half maximal effective concentrations (EC50) obtained after 10 min bioassay, 2.9, 1.0, 0.7 and 18.3 mg L(-1) for copper, zinc, acetic acid and 2-phenylethanol respectively, were in agreement with previously reported values for longer bioassays (around 60 min). This method represents a promising alternative for fast and sensitive water toxicity monitoring, opening the possibility of quick in situ analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Efficient sensitivity analysis and optimization of a helicopter rotor

    NASA Technical Reports Server (NTRS)

    Lim, Joon W.; Chopra, Inderjit

    1989-01-01

    Aeroelastic optimization of a system essentially consists of the determination of the optimum values of design variables which minimize the objective function and satisfy certain aeroelastic and geometric constraints. The process of aeroelastic optimization analysis is illustrated. To carry out aeroelastic optimization effectively, one needs a reliable analysis procedure to determine steady response and stability of a rotor system in forward flight. The rotor dynamic analysis used in the present study developed inhouse at the University of Maryland is based on finite elements in space and time. The analysis consists of two major phases: vehicle trim and rotor steady response (coupled trim analysis), and aeroelastic stability of the blade. For a reduction of helicopter vibration, the optimization process requires the sensitivity derivatives of the objective function and aeroelastic stability constraints. For this, the derivatives of steady response, hub loads and blade stability roots are calculated using a direct analytical approach. An automated optimization procedure is developed by coupling the rotor dynamic analysis, design sensitivity analysis and constrained optimization code CONMIN.

  12. Variational Methods in Sensitivity Analysis and Optimization for Aerodynamic Applications

    NASA Technical Reports Server (NTRS)

    Ibrahim, A. H.; Hou, G. J.-W.; Tiwari, S. N. (Principal Investigator)

    1996-01-01

    Variational methods (VM) sensitivity analysis, which is the continuous alternative to the discrete sensitivity analysis, is employed to derive the costate (adjoint) equations, the transversality conditions, and the functional sensitivity derivatives. In the derivation of the sensitivity equations, the variational methods use the generalized calculus of variations, in which the variable boundary is considered as the design function. The converged solution of the state equations together with the converged solution of the costate equations are integrated along the domain boundary to uniquely determine the functional sensitivity derivatives with respect to the design function. The determination of the sensitivity derivatives of the performance index or functional entails the coupled solutions of the state and costate equations. As the stable and converged numerical solution of the costate equations with their boundary conditions are a priori unknown, numerical stability analysis is performed on both the state and costate equations. Thereafter, based on the amplification factors obtained by solving the generalized eigenvalue equations, the stability behavior of the costate equations is discussed and compared with the state (Euler) equations. The stability analysis of the costate equations suggests that the converged and stable solution of the costate equation is possible only if the computational domain of the costate equations is transformed to take into account the reverse flow nature of the costate equations. The application of the variational methods to aerodynamic shape optimization problems is demonstrated for internal flow problems at supersonic Mach number range. The study shows, that while maintaining the accuracy of the functional sensitivity derivatives within the reasonable range for engineering prediction purposes, the variational methods show a substantial gain in computational efficiency, i.e., computer time and memory, when compared with the finite difference sensitivity analysis.

  13. Determination of IgE antibodies to the benzylpenicilloyl determinant: a comparison of the sensitivity and specificity of three radio allergo sorbent test methods.

    PubMed

    Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E

    1997-01-01

    The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.

  14. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    ERIC Educational Resources Information Center

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  15. [Comparative evaluation of the sensitivity of Acinetobacter to colistin, using the prediffusion and minimum inhibitory concentration methods: detection of heteroresistant isolates].

    PubMed

    Herrera, Melina E; Mobilia, Liliana N; Posse, Graciela R

    2011-01-01

    The objective of this study is to perform a comparative evaluation of the prediffusion and minimum inhibitory concentration (MIC) methods for the detection of sensitivity to colistin, and to detect Acinetobacter baumanii-calcoaceticus complex (ABC) heteroresistant isolates to colistin. We studied 75 isolates of ABC recovered from clinically significant samples obtained from various centers. Sensitivity to colistin was determined by prediffusion as well as by MIC. All the isolates were sensitive to colistin, with MIC = 2µg/ml. The results were analyzed by dispersion graph and linear regression analysis, revealing that the prediffusion method did not correlate with the MIC values for isolates sensitive to colistin (r² = 0.2017). Detection of heteroresistance to colistin was determined by plaque efficiency of all the isolates with the same initial MICs of 2, 1, and 0.5 µg/ml, which resulted in 14 of them with a greater than 8-fold increase in the MIC in some cases. When the sensitivity of these resistant colonies was determined by prediffusion, the resulting dispersion graph and linear regression analysis yielded an r² = 0.604, which revealed a correlation between the methodologies used.

  16. Peptidylation for the determination of low-molecular-weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Tang, Feng; Cen, Si-Ying; He, Huan; Liu, Yi; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-05-23

    Determination of low-molecular-weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) has been a great challenge in the analytical research field. Here we developed a universal peptide-based derivatization (peptidylation) strategy for the sensitive analysis of low-molecular-weight compounds by MALDI-TOF-MS. Upon peptidylation, the molecular weights of target analytes increase, thus avoiding serious matrix ion interference in the low-molecular-weight region in MALDI-TOF-MS. Since peptides typically exhibit good signal response during MALDI-TOF-MS analysis, peptidylation endows high detection sensitivities of low-molecular-weight analytes. As a proof-of-concept, we analyzed low-molecular-weight compounds of aldehydes and thiols by the developed peptidylation strategy. Our results showed that aldehydes and thiols can be readily determined upon peptidylation, thus realizing the sensitive and efficient determination of low-molecular-weight compounds by MALDI-TOF-MS. Moreover, target analytes also can be unambiguously detected in biological samples using the peptidylation strategy. The established peptidylation strategy is a universal strategy and can be extended to the sensitive analysis of various low-molecular-weight compounds by MALDI-TOF-MS, which may be potentially used in areas such as metabolomics.

  17. ’Coxiella Burnetii’ Vaccine Development: Lipopolysaccharide Structural Analysis

    DTIC Science & Technology

    1991-02-20

    Analytical instrumentation and methodology is presented for the determination of endotoxin -related structures at much improved sensitivity and... ENDOTOXIN CHARACTERIZATION BY SFC .......................... 10 III. COXIELLA BURNETII LPS CHARACTERIZATION A. EXPERIMENTAL...period for the determination of endotoxin -related structures at much improved sensitivity and specificity. Reports, and their applications, are listed in

  18. Design sensitivity analysis of rotorcraft airframe structures for vibration reduction

    NASA Technical Reports Server (NTRS)

    Murthy, T. Sreekanta

    1987-01-01

    Optimization of rotorcraft structures for vibration reduction was studied. The objective of this study is to develop practical computational procedures for structural optimization of airframes subject to steady-state vibration response constraints. One of the key elements of any such computational procedure is design sensitivity analysis. A method for design sensitivity analysis of airframes under vibration response constraints is presented. The mathematical formulation of the method and its implementation as a new solution sequence in MSC/NASTRAN are described. The results of the application of the method to a simple finite element stick model of the AH-1G helicopter airframe are presented and discussed. Selection of design variables that are most likely to bring about changes in the response at specified locations in the airframe is based on consideration of forced response strain energy. Sensitivity coefficients are determined for the selected design variable set. Constraints on the natural frequencies are also included in addition to the constraints on the steady-state response. Sensitivity coefficients for these constraints are determined. Results of the analysis and insights gained in applying the method to the airframe model are discussed. The general nature of future work to be conducted is described.

  19. Methods of determining complete sensor requirements for autonomous mobility

    NASA Technical Reports Server (NTRS)

    Curtis, Steven A. (Inventor)

    2012-01-01

    A method of determining complete sensor requirements for autonomous mobility of an autonomous system includes computing a time variation of each behavior of a set of behaviors of the autonomous system, determining mobility sensitivity to each behavior of the autonomous system, and computing a change in mobility based upon the mobility sensitivity to each behavior and the time variation of each behavior. The method further includes determining the complete sensor requirements of the autonomous system through analysis of the relative magnitude of the change in mobility, the mobility sensitivity to each behavior, and the time variation of each behavior, wherein the relative magnitude of the change in mobility, the mobility sensitivity to each behavior, and the time variation of each behavior are characteristic of the stability of the autonomous system.

  20. Determining the best treatment for simple bone cyst: a decision analysis.

    PubMed

    Lee, Seung Yeol; Chung, Chin Youb; Lee, Kyoung Min; Sung, Ki Hyuk; Won, Sung Hun; Choi, In Ho; Cho, Tae-Joon; Yoo, Won Joon; Yeo, Ji Hyun; Park, Moon Seok

    2014-03-01

    The treatment of simple bone cysts (SBC) in children varies significantly among physicians. This study examined which procedure is better for the treatment of SBC, using a decision analysis based on current published evidence. A decision tree focused on five treatment modalities of SBC (observation, steroid injection, autologous bone marrow injection, decompression, and curettage with bone graft) were created. Each treatment modality was further branched, according to the presence and severity of complications. The probabilities of all cases were obtained by literature review. A roll back tool was utilized to determine the most preferred treatment modality. One-way sensitivity analysis was performed to determine the threshold value of the treatment modalities. Two-way sensitivity analysis was utilized to examine the joint impact of changes in probabilities of two parameters. The decision model favored autologous bone marrow injection. The expected value of autologous bone marrow injection was 0.9445, while those of observation, steroid injection, decompression, and curettage and bone graft were 0.9318, 0.9400, 0.9395, and 0.9342, respectively. One-way sensitivity analysis showed that autologous bone marrow injection was better than that of decompression for the expected value when the rate of pathologic fracture, or positive symptoms of SBC after autologous bone marrow injection, was lower than 20.4%. In our study, autologous bone marrow injection was found to be the best choice of treatment of SBC. However, the results were sensitive to the rate of pathologic fracture after treatment of SBC. Physicians should consider the possibility of pathologic fracture when they determine a treatment method for SBC.

  1. Weighting-Based Sensitivity Analysis in Causal Mediation Studies

    ERIC Educational Resources Information Center

    Hong, Guanglei; Qin, Xu; Yang, Fan

    2018-01-01

    Through a sensitivity analysis, the analyst attempts to determine whether a conclusion of causal inference could be easily reversed by a plausible violation of an identification assumption. Analytic conclusions that are harder to alter by such a violation are expected to add a higher value to scientific knowledge about causality. This article…

  2. Rapid separation on copper powder of total mercury in blood and determination of mercury by flameless atomic absorption spectrometry.

    PubMed

    Dogan, S; Haerdi, W

    1979-01-01

    The determination of mercury in blood by flameless atomic absorption spectrometry (FAAS) has been described. Prior to its analysis, the sample was decomposed by combustion and separated on a copper powder micro-column. A special type of cell has been used which gives a better sensitivity compared with the types of cells described in the literature and the method of FAAS analysis has been improved. The sensitivity of 0.1 ng for 1% absorbance was observed and the standard deviation for six determinations at this level was found to be +/- 0.05 ng, for 95% probability.

  3. Highly sensitive catalytic spectrophotometric determination of ruthenium

    NASA Astrophysics Data System (ADS)

    Naik, Radhey M.; Srivastava, Abhishek; Prasad, Surendra

    2008-01-01

    A new and highly sensitive catalytic kinetic method (CKM) for the determination of ruthenium(III) has been established based on its catalytic effect on the oxidation of L-phenylalanine ( L-Pheala) by KMnO 4 in highly alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance at 526 nm. The proposed CKM is based on the fixed time procedure under optimum reaction conditions. It relies on the linear relationship where the change in the absorbance (Δ At) versus added Ru(III) amounts in the range of 0.101-2.526 ng ml -1 is plotted. Under the optimum conditions, the sensitivity of the proposed method, i.e. the limit of detection corresponding to 5 min is 0.08 ng ml -1, and decreases with increased time of analysis. The method is featured with good accuracy and reproducibility for ruthenium(III) determination. The ruthenium(III) has also been determined in presence of several interfering and non-interfering cations, anions and polyaminocarboxylates. No foreign ions interfered in the determination ruthenium(III) up to 20-fold higher concentration of foreign ions. In addition to standard solutions analysis, this method was successfully applied for the quantitative determination of ruthenium(III) in drinking water samples. The method is highly sensitive, selective and very stable. A review of recently published catalytic spectrophotometric methods for the determination of ruthenium(III) has also been presented for comparison.

  4. Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis

    PubMed Central

    Adnan, Tassha Hilda

    2016-01-01

    Sensitivity and specificity analysis is commonly used for screening and diagnostic tests. The main issue researchers face is to determine the sufficient sample sizes that are related with screening and diagnostic studies. Although the formula for sample size calculation is available but concerning majority of the researchers are not mathematicians or statisticians, hence, sample size calculation might not be easy for them. This review paper provides sample size tables with regards to sensitivity and specificity analysis. These tables were derived from formulation of sensitivity and specificity test using Power Analysis and Sample Size (PASS) software based on desired type I error, power and effect size. The approaches on how to use the tables were also discussed. PMID:27891446

  5. First- and Second-Order Sensitivity Analysis of a P-Version Finite Element Equation Via Automatic Differentiation

    NASA Technical Reports Server (NTRS)

    Hou, Gene

    1998-01-01

    Sensitivity analysis is a technique for determining derivatives of system responses with respect to design parameters. Among many methods available for sensitivity analysis, automatic differentiation has been proven through many applications in fluid dynamics and structural mechanics to be an accurate and easy method for obtaining derivatives. Nevertheless, the method can be computational expensive and can require a high memory space. This project will apply an automatic differentiation tool, ADIFOR, to a p-version finite element code to obtain first- and second- order then-nal derivatives, respectively. The focus of the study is on the implementation process and the performance of the ADIFOR-enhanced codes for sensitivity analysis in terms of memory requirement, computational efficiency, and accuracy.

  6. Preparation for implementation of the mechanistic-empirical pavement design guide in Michigan : part 2 - evaluation of rehabilitation fixes (part 2).

    DOT National Transportation Integrated Search

    2013-08-01

    The overall goal of Global Sensitivity Analysis (GSA) is to determine sensitivity of pavement performance prediction models to the variation in the design input values. The main difference between GSA and detailed sensitivity analyses is the way the ...

  7. Variational Methods in Design Optimization and Sensitivity Analysis for Two-Dimensional Euler Equations

    NASA Technical Reports Server (NTRS)

    Ibrahim, A. H.; Tiwari, S. N.; Smith, R. E.

    1997-01-01

    Variational methods (VM) sensitivity analysis employed to derive the costate (adjoint) equations, the transversality conditions, and the functional sensitivity derivatives. In the derivation of the sensitivity equations, the variational methods use the generalized calculus of variations, in which the variable boundary is considered as the design function. The converged solution of the state equations together with the converged solution of the costate equations are integrated along the domain boundary to uniquely determine the functional sensitivity derivatives with respect to the design function. The application of the variational methods to aerodynamic shape optimization problems is demonstrated for internal flow problems at supersonic Mach number range. The study shows, that while maintaining the accuracy of the functional sensitivity derivatives within the reasonable range for engineering prediction purposes, the variational methods show a substantial gain in computational efficiency, i.e., computer time and memory, when compared with the finite difference sensitivity analysis.

  8. Phosphorus Determination by Derivative Activation Analysis: A Multifaceted Radiochemical Application.

    ERIC Educational Resources Information Center

    Kleppinger, E. W.; And Others

    1984-01-01

    Although determination of phosphorus is important in biology, physiology, and environmental science, traditional gravimetric and colorimetric methods are cumbersome and lack the requisite sensitivity. Therefore, a derivative activation analysis method is suggested. Background information, procedures, and results are provided. (JN)

  9. Sensitivity Analysis of Flux Determination in Heart by H2 18O -provided Labeling Using a Dynamic Isotopologue Model of Energy Transfer Pathways

    PubMed Central

    Schryer, David W.; Peterson, Pearu; Illaste, Ardo; Vendelin, Marko

    2012-01-01

    To characterize intracellular energy transfer in the heart, two organ-level methods have frequently been employed: inversion and saturation transfer, and dynamic labeling. Creatine kinase (CK) fluxes obtained by following oxygen labeling have been considerably smaller than the fluxes determined by saturation transfer. It has been proposed that dynamic labeling determines net flux through CK shuttle, whereas saturation transfer measures total unidirectional flux. However, to our knowledge, no sensitivity analysis of flux determination by oxygen labeling has been performed, limiting our ability to compare flux distributions predicted by different methods. Here we analyze oxygen labeling in a physiological heart phosphotransfer network with active CK and adenylate kinase (AdK) shuttles and establish which fluxes determine the labeling state. A mathematical model consisting of a system of ordinary differential equations was composed describing enrichment in each phosphoryl group and inorganic phosphate. By varying flux distributions in the model and calculating the labeling, we analyzed labeling sensitivity to different fluxes in the heart. We observed that the labeling state is predominantly sensitive to total unidirectional CK and AdK fluxes and not to net fluxes. We conclude that measuring dynamic incorporation of into the high-energy phosphotransfer network in heart does not permit unambiguous determination of energetic fluxes with a higher magnitude than the ATP synthase rate when the bidirectionality of fluxes is taken into account. Our analysis suggests that the flux distributions obtained using dynamic labeling, after removing the net flux assumption, are comparable with those from inversion and saturation transfer. PMID:23236266

  10. On understanding the relationship between structure in the potential surface and observables in classical dynamics: A functional sensitivity analysis approach

    NASA Astrophysics Data System (ADS)

    Judson, Richard S.; Rabitz, Herschel

    1987-04-01

    The relationship between structure in the potential surface and classical mechanical observables is examined by means of functional sensitivity analysis. Functional sensitivities provide maps of the potential surface, highlighting those regions that play the greatest role in determining the behavior of observables. A set of differential equations for the sensitivities of the trajectory components are derived. These are then solved using a Green's function method. It is found that the sensitivities become singular at the trajectory turning points with the singularities going as η-3/2, with η being the distance from the nearest turning point. The sensitivities are zero outside of the energetically and dynamically allowed region of phase space. A second set of equations is derived from which the sensitivities of observables can be directly calculated. An adjoint Green's function technique is employed, providing an efficient method for numerically calculating these quantities. Sensitivity maps are presented for a simple collinear atom-diatom inelastic scattering problem and for two Henon-Heiles type Hamiltonians modeling intramolecular processes. It is found that the positions of the trajectory caustics in the bound state problem determine regions of the highest potential surface sensitivities. In the scattering problem (which is impulsive, so that ``sticky'' collisions did not occur), the positions of the turning points of the individual trajectory components determine the regions of high sensitivity. In both cases, these lines of singularities are superimposed on a rich background structure. Most interesting is the appearance of classical interference effects. The interference features in the sensitivity maps occur most noticeably where two or more lines of turning points cross. The important practical motivation for calculating the sensitivities derives from the fact that the potential is a function, implying that any direct attempt to understand how local potential regions affect the behavior of the observables by repeatedly and systematically altering the potential will be prohibitively expensive. The functional sensitivity method enables one to perform this analysis at a fraction of the computational labor required for the direct method.

  11. Development of a sensitivity analysis technique for multiloop flight control systems

    NASA Technical Reports Server (NTRS)

    Vaillard, A. H.; Paduano, J.; Downing, D. R.

    1985-01-01

    This report presents the development and application of a sensitivity analysis technique for multiloop flight control systems. This analysis yields very useful information on the sensitivity of the relative-stability criteria of the control system, with variations or uncertainties in the system and controller elements. The sensitivity analysis technique developed is based on the computation of the singular values and singular-value gradients of a feedback-control system. The method is applicable to single-input/single-output as well as multiloop continuous-control systems. Application to sampled-data systems is also explored. The sensitivity analysis technique was applied to a continuous yaw/roll damper stability augmentation system of a typical business jet, and the results show that the analysis is very useful in determining the system elements which have the largest effect on the relative stability of the closed-loop system. As a secondary product of the research reported here, the relative stability criteria based on the concept of singular values were explored.

  12. Acceleration and sensitivity analysis of lattice kinetic Monte Carlo simulations using parallel processing and rate constant rescaling

    NASA Astrophysics Data System (ADS)

    Núñez, M.; Robie, T.; Vlachos, D. G.

    2017-10-01

    Kinetic Monte Carlo (KMC) simulation provides insights into catalytic reactions unobtainable with either experiments or mean-field microkinetic models. Sensitivity analysis of KMC models assesses the robustness of the predictions to parametric perturbations and identifies rate determining steps in a chemical reaction network. Stiffness in the chemical reaction network, a ubiquitous feature, demands lengthy run times for KMC models and renders efficient sensitivity analysis based on the likelihood ratio method unusable. We address the challenge of efficiently conducting KMC simulations and performing accurate sensitivity analysis in systems with unknown time scales by employing two acceleration techniques: rate constant rescaling and parallel processing. We develop statistical criteria that ensure sufficient sampling of non-equilibrium steady state conditions. Our approach provides the twofold benefit of accelerating the simulation itself and enabling likelihood ratio sensitivity analysis, which provides further speedup relative to finite difference sensitivity analysis. As a result, the likelihood ratio method can be applied to real chemistry. We apply our methodology to the water-gas shift reaction on Pt(111).

  13. Analysis of Fluorotelomer Alcohols in Soils: Optimization of Extraction and Chromatography

    EPA Science Inventory

    This article describes the development of an analytical method for the determination of fluorotelomer alcohols (FTOHs) in soil. The sensitive and selective determination of the telomer alcohols was performed by extraction with mthyl tert-butyl ether (MTBE) and analysis of the ext...

  14. Effectiveness of Quantitative Real Time PCR in Long-Term Follow-up of Chronic Myeloid Leukemia Patients.

    PubMed

    Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin

    2015-08-01

    To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.

  15. Characterization of iron-doped lithium niobate for holographic storage applications

    NASA Technical Reports Server (NTRS)

    Shah, R. R.; Kim, D. M.; Rabson, T. A.; Tittel, F. K.

    1976-01-01

    A comprehensive characterization of chemical and holographic properties of eight systematically chosen Fe:LiNbO3 crystals is performed in order to determine optimum performance of the crystals in holographic storage and display applications. The discussion covers determination of Fe(2+) and Fe(3+) ion concentrations in Fe:LiNbO3 system from optical absorption and EPR measurements; establishment of the relation between the photorefractive sensitivity of Fe(2+) and Fe(3+) concentrations; study of the spectral dependence, the effect of oxygen annealing, and of other impurities on the photorefractive sensitivity; analysis of the diffraction efficiency curves for different crystals and corresponding sensitivities with the dynamic theory of hologram formation; and determination of the bulk photovoltaic fields as a function of Fe(2+) concentrations. In addition to the absolute Fe(2+) concentration, the relative concentrations of Fe(2+) and Fe(3+) ions are also important in determining the photorefractive sensitivity. There exists an optimal set of crystal characteristics for which the photorefractive sensitivity is most favorable.

  16. Global Sensitivity of Simulated Water Balance Indicators Under Future Climate Change in the Colorado Basin

    DOE PAGES

    Bennett, Katrina Eleanor; Urrego Blanco, Jorge Rolando; Jonko, Alexandra; ...

    2017-11-20

    The Colorado River basin is a fundamentally important river for society, ecology and energy in the United States. Streamflow estimates are often provided using modeling tools which rely on uncertain parameters; sensitivity analysis can help determine which parameters impact model results. Despite the fact that simulated flows respond to changing climate and vegetation in the basin, parameter sensitivity of the simulations under climate change has rarely been considered. In this study, we conduct a global sensitivity analysis to relate changes in runoff, evapotranspiration, snow water equivalent and soil moisture to model parameters in the Variable Infiltration Capacity (VIC) hydrologic model.more » Here, we combine global sensitivity analysis with a space-filling Latin Hypercube sampling of the model parameter space and statistical emulation of the VIC model to examine sensitivities to uncertainties in 46 model parameters following a variance-based approach.« less

  17. Global Sensitivity of Simulated Water Balance Indicators Under Future Climate Change in the Colorado Basin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Katrina Eleanor; Urrego Blanco, Jorge Rolando; Jonko, Alexandra

    The Colorado River basin is a fundamentally important river for society, ecology and energy in the United States. Streamflow estimates are often provided using modeling tools which rely on uncertain parameters; sensitivity analysis can help determine which parameters impact model results. Despite the fact that simulated flows respond to changing climate and vegetation in the basin, parameter sensitivity of the simulations under climate change has rarely been considered. In this study, we conduct a global sensitivity analysis to relate changes in runoff, evapotranspiration, snow water equivalent and soil moisture to model parameters in the Variable Infiltration Capacity (VIC) hydrologic model.more » Here, we combine global sensitivity analysis with a space-filling Latin Hypercube sampling of the model parameter space and statistical emulation of the VIC model to examine sensitivities to uncertainties in 46 model parameters following a variance-based approach.« less

  18. Model-based POD study of manual ultrasound inspection and sensitivity analysis using metamodel

    NASA Astrophysics Data System (ADS)

    Ribay, Guillemette; Artusi, Xavier; Jenson, Frédéric; Reece, Christopher; Lhuillier, Pierre-Emile

    2016-02-01

    The reliability of NDE can be quantified by using the Probability of Detection (POD) approach. Former studies have shown the potential of the model-assisted POD (MAPOD) approach to replace expensive experimental determination of POD curves. In this paper, we make use of CIVA software to determine POD curves for a manual ultrasonic inspection of a heavy component, for which a whole experimental POD campaign was not available. The influential parameters were determined by expert analysis. The semi-analytical models used in CIVA for wave propagation and beam-defect interaction have been validated in the range of variation of the influential parameters by comparison with finite element modelling (Athena). The POD curves are computed for « hit/miss » and « â versus a » analysis. The verification of Berens hypothesis is evaluated by statistical tools. A sensitivity study is performed to measure the relative influence of parameters on the defect response amplitude variance, using the Sobol sensitivity index. A meta-model is also built to reduce computing cost and enhance the precision of estimated index.

  19. A Sensitivity Analysis of a Map of Habitat Quality for the California Spotted Owl (Strix occidentalis occidentalis) in southern California

    Treesearch

    Ellen M. Hines; Janet Franklin

    1997-01-01

    Using a Geographic Information System (GIS), a sensitivity analysis was performed on estimated mapping errors in vegetation type, forest canopy cover percentage, and tree crown size to determine the possible effects error in these data might have on delineating suitable habitat for the California Spotted Owl (Strix occidentalis occidentalis) in...

  20. Modeling and Error Analysis of a Superconducting Gravity Gradiometer.

    DTIC Science & Technology

    1979-08-01

    fundamental limit to instrument - -1- sensitivity is the thermal noise of the sensor . For the gradiometer design outlined above, the best sensitivity...Mapoles at Stanford. Chapter IV determines the relation between dynamic range, the sensor Q, and the thermal noise of the cryogenic accelerometer. An...C.1 Accelerometer Optimization (1) Development and optimization of the loaded diaphragm sensor . (2) Determination of the optimal values of the

  1. [The history of hepatitis B virus-related determination tests and inspection and the measurements of problems in Japan].

    PubMed

    Shibata, Hiroshi

    2013-09-01

    Since Hepatitis B virus was detected as the cause of hepatitis, many high-sensitive measurement methods have been developed. In the development history, there are many problems in accuracy, sensitivity and health insurance regulations among different types of kits with different measurement principles. Advanced medical treatments cause problems of gene mutation or reactivation of HBV, leading to the necessity for high sensitive and sophisticated determination. The history of clinical analysis for the detection of HBV was reviewed from the viewpoint of our experiences.

  2. Optimizing the interpretation of CT for appendicitis: modeling health utilities for clinical practice.

    PubMed

    Blackmore, C Craig; Terasawa, Teruhiko

    2006-02-01

    Error in radiology can be reduced by standardizing the interpretation of imaging studies to the optimum sensitivity and specificity. In this report, the authors demonstrate how the optimal interpretation of appendiceal computed tomography (CT) can be determined and how it varies in different clinical scenarios. Utility analysis and receiver operating characteristic (ROC) curve modeling were used to determine the trade-off between false-positive and false-negative test results to determine the optimal operating point on the ROC curve for the interpretation of appendicitis CT. Modeling was based on a previous meta-analysis for the accuracy of CT and on literature estimates of the utilities of various health states. The posttest probability of appendicitis was derived using Bayes's theorem. At a low prevalence of disease (screening), appendicitis CT should be interpreted at high specificity (97.7%), even at the expense of lower sensitivity (75%). Conversely, at a high probability of disease, high sensitivity (97.4%) is preferred (specificity 77.8%). When the clinical diagnosis of appendicitis is equivocal, CT interpretation should emphasize both sensitivity and specificity (sensitivity 92.3%, specificity 91.5%). Radiologists can potentially decrease medical error and improve patient health by varying the interpretation of appendiceal CT on the basis of the clinical probability of appendicitis. This report is an example of how utility analysis can be used to guide radiologists in the interpretation of imaging studies and provide guidance on appropriate targets for the standardization of interpretation.

  3. Results of an integrated structure/control law design sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Gilbert, Michael G.

    1989-01-01

    A design sensitivity analysis method for Linear Quadratic Cost, Gaussian (LQG) optimal control laws, which predicts change in the optimal control law due to changes in fixed problem parameters using analytical sensitivity equations is discussed. Numerical results of a design sensitivity analysis for a realistic aeroservoelastic aircraft example are presented. In this example, the sensitivity of the optimally controlled aircraft's response to various problem formulation and physical aircraft parameters is determined. These results are used to predict the aircraft's new optimally controlled response if the parameter was to have some other nominal value during the control law design process. The sensitivity results are validated by recomputing the optimal control law for discrete variations in parameters, computing the new actual aircraft response, and comparing with the predicted response. These results show an improvement in sensitivity accuracy for integrated design purposes over methods which do not include changes in the optimal control law. Use of the analytical LQG sensitivity expressions is also shown to be more efficient than finite difference methods for the computation of the equivalent sensitivity information.

  4. Sample pooling for real-time PCR detection and virulence determination of the footrot pathogen Dichelobacter nodosus.

    PubMed

    Frosth, Sara; König, Ulrika; Nyman, Ann-Kristin; Aspán, Anna

    2017-09-01

    Dichelobacter nodosus is the principal cause of ovine footrot and strain virulence is an important factor in disease severity. Therefore, detection and virulence determination of D. nodosus is important for proper diagnosis of the disease. Today this is possible by real-time PCR analysis. Analysis of large numbers of samples is costly and laborious; therefore, pooling of individual samples is common in surveillance programs. However, pooling can reduce the sensitivity of the method. The aim of this study was to develop a pooling method for real-time PCR analysis that would allow sensitive detection and simultaneous virulence determination of D. nodosus. A total of 225 sheep from 17 flocks were sampled using ESwabs within the Swedish Footrot Control Program in 2014. Samples were first analysed individually and then in pools of five by real-time PCR assays targeting the 16S rRNA and aprV2/B2 genes of D. nodosus. Each pool consisted of four negative and one positive D. nodosus samples with varying amounts of the bacterium. In the individual analysis, 61 (27.1%) samples were positive in the 16S rRNA and the aprV2/B2 PCR assays and 164 (72.9%) samples were negative. All samples positive in the aprV2/B2 PCR-assay were of aprB2 variant. The pooled analysis showed that all 41 pools were also positive for D. nodosus 16S rRNA and the aprB2 variant. The diagnostic sensitivity for pooled and individual samples was therefore similar. Our method includes concentration of the bacteria before DNA-extraction. This may account for the maintenance of diagnostic sensitivity. Diagnostic sensitivity in the real-time PCR assays of the pooled samples were comparable to the sensitivity obtained for individually analysed samples. Even sub-clinical infections were able to be detected in the pooled PCR samples which is important for control of the disease. This method may therefore be implemented in footrot control programs where it can replace analysis of individual samples.

  5. Open pit mining profit maximization considering selling stage and waste rehabilitation cost

    NASA Astrophysics Data System (ADS)

    Muttaqin, B. I. A.; Rosyidi, C. N.

    2017-11-01

    In open pit mining activities, determination of the cut-off grade becomes crucial for the company since the cut-off grade affects how much profit will be earned for the mining company. In this study, we developed a cut-off grade determination mode for the open pit mining industry considering the cost of mining, waste removal (rehabilitation) cost, processing cost, fixed cost, and selling stage cost. The main goal of this study is to develop a model of cut-off grade determination to get the maximum total profit. Secondly, this study is also developed to observe the model of sensitivity based on changes in the cost components. The optimization results show that the models can help mining company managers to determine the optimal cut-off grade and also estimate how much profit that can be earned by the mining company. To illustrate the application of the models, a numerical example and a set of sensitivity analysis are presented. From the results of sensitivity analysis, we conclude that the changes in the sales price greatly affects the optimal cut-off value and the total profit.

  6. Maintaining gender sensitivity in the family practice: facilitators and barriers.

    PubMed

    Celik, Halime; Lagro-Janssen, Toine; Klinge, Ineke; van der Weijden, Trudy; Widdershoven, Guy

    2009-12-01

    This study aims to identify the facilitators and barriers perceived by General Practitioners (GPs) to maintain a gender perspective in family practice. Nine semi-structured interviews were conducted among nine pairs of GPs. The data were analysed by means of deductive content analysis using theory-based methods to generate facilitators and barriers to gender sensitivity. Gender sensitivity in family practice can be influenced by several factors which ultimately determine the extent to which a gender sensitive approach is satisfactorily practiced by GPs in the doctor-patient relationship. Gender awareness, repetition and reminders, motivation triggers and professional guidelines were found to facilitate gender sensitivity. On the other hand, lacking skills and routines, scepticism, heavy workload and the timing of implementation were found to be barriers to gender sensitivity. While the potential effect of each factor affecting gender sensitivity in family practice has been elucidated, the effects of the interplay between these factors still need to be determined.

  7. Development of a rapid, simple and sensitive HPLC-FLD method for determination of rhodamine B in chili-containing products.

    PubMed

    Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu

    2014-12-01

    In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations <10%. The overall recoveries are in the range of 98-103% in chili powder and in the range of 87-100% in chili oil depending on the concentration of rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Determining thickness and refractive index from free-standing ultra-thin polymer films with spectroscopic ellipsometry

    DOE PAGES

    Hilfiker, James N.; Stadermann, Michael; Sun, Jianing; ...

    2016-08-27

    It is a well-known challenge to determine refractive index (n) from ultra-thin films where the thickness is less than about 10 nm. In this paper, we discovered an interesting exception to this issue while characterizing spectroscopic ellipsometry (SE) data from isotropic, free-standing polymer films. Ellipsometry analysis shows that both thickness and refractive index can be independently determined for free-standing films as thin as 5 nm. Simulations further confirm an orthogonal separation between thickness and index effects on the experimental SE data. Effects of angle of incidence and wavelength on the data and sensitivity are discussed. Finally, while others have demonstratedmore » methods to determine refractive index from ultra-thin films, our analysis provides the first results to demonstrate high-sensitivity to the refractive index from ultra-thin layers.« less

  9. Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.

    2016-09-20

    These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such asmore » MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.« less

  10. Preliminary Thermal-Mechanical Sizing of Metallic TPS: Process Development and Sensitivity Studies

    NASA Technical Reports Server (NTRS)

    Poteet, Carl C.; Abu-Khajeel, Hasan; Hsu, Su-Yuen

    2002-01-01

    The purpose of this research was to perform sensitivity studies and develop a process to perform thermal and structural analysis and sizing of the latest Metallic Thermal Protection System (TPS) developed at NASA LaRC (Langley Research Center). Metallic TPS is a key technology for reducing the cost of reusable launch vehicles (RLV), offering the combination of increased durability and competitive weights when compared to other systems. Accurate sizing of metallic TPS requires combined thermal and structural analysis. Initial sensitivity studies were conducted using transient one-dimensional finite element thermal analysis to determine the influence of various TPS and analysis parameters on TPS weight. The thermal analysis model was then used in combination with static deflection and failure mode analysis of the sandwich panel outer surface of the TPS to obtain minimum weight TPS configurations at three vehicle stations on the windward centerline of a representative RLV. The coupled nature of the analysis requires an iterative analysis process, which will be described herein. Findings from the sensitivity analysis are reported, along with TPS designs at the three RLV vehicle stations considered.

  11. Proof-of-Concept Study for Uncertainty Quantification and Sensitivity Analysis using the BRL Shaped-Charge Example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Justin Matthew

    These are the slides for a graduate presentation at Mississippi State University. It covers the following: the BRL Shaped-Charge Geometry in PAGOSA, mesh refinement study, surrogate modeling using a radial basis function network (RBFN), ruling out parameters using sensitivity analysis (equation of state study), uncertainty quantification (UQ) methodology, and sensitivity analysis (SA) methodology. In summary, a mesh convergence study was used to ensure that solutions were numerically stable by comparing PDV data between simulations. A Design of Experiments (DOE) method was used to reduce the simulation space to study the effects of the Jones-Wilkins-Lee (JWL) Parameters for the Composition Bmore » main charge. Uncertainty was quantified by computing the 95% data range about the median of simulation output using a brute force Monte Carlo (MC) random sampling method. Parameter sensitivities were quantified using the Fourier Amplitude Sensitivity Test (FAST) spectral analysis method where it was determined that detonation velocity, initial density, C1, and B1 controlled jet tip velocity.« less

  12. Sensitivity analysis in a Lassa fever deterministic mathematical model

    NASA Astrophysics Data System (ADS)

    Abdullahi, Mohammed Baba; Doko, Umar Chado; Mamuda, Mamman

    2015-05-01

    Lassa virus that causes the Lassa fever is on the list of potential bio-weapons agents. It was recently imported into Germany, the Netherlands, the United Kingdom and the United States as a consequence of the rapid growth of international traffic. A model with five mutually exclusive compartments related to Lassa fever is presented and the basic reproduction number analyzed. A sensitivity analysis of the deterministic model is performed. This is done in order to determine the relative importance of the model parameters to the disease transmission. The result of the sensitivity analysis shows that the most sensitive parameter is the human immigration, followed by human recovery rate, then person to person contact. This suggests that control strategies should target human immigration, effective drugs for treatment and education to reduced person to person contact.

  13. Uncertainty Analysis of Decomposing Polyurethane Foam

    NASA Technical Reports Server (NTRS)

    Hobbs, Michael L.; Romero, Vicente J.

    2000-01-01

    Sensitivity/uncertainty analyses are necessary to determine where to allocate resources for improved predictions in support of our nation's nuclear safety mission. Yet, sensitivity/uncertainty analyses are not commonly performed on complex combustion models because the calculations are time consuming, CPU intensive, nontrivial exercises that can lead to deceptive results. To illustrate these ideas, a variety of sensitivity/uncertainty analyses were used to determine the uncertainty associated with thermal decomposition of polyurethane foam exposed to high radiative flux boundary conditions. The polyurethane used in this study is a rigid closed-cell foam used as an encapsulant. Related polyurethane binders such as Estane are used in many energetic materials of interest to the JANNAF community. The complex, finite element foam decomposition model used in this study has 25 input parameters that include chemistry, polymer structure, and thermophysical properties. The response variable was selected as the steady-state decomposition front velocity calculated as the derivative of the decomposition front location versus time. An analytical mean value sensitivity/uncertainty (MV) analysis was used to determine the standard deviation by taking numerical derivatives of the response variable with respect to each of the 25 input parameters. Since the response variable is also a derivative, the standard deviation was essentially determined from a second derivative that was extremely sensitive to numerical noise. To minimize the numerical noise, 50-micrometer element dimensions and approximately 1-msec time steps were required to obtain stable uncertainty results. As an alternative method to determine the uncertainty and sensitivity in the decomposition front velocity, surrogate response surfaces were generated for use with a constrained Latin Hypercube Sampling (LHS) technique. Two surrogate response surfaces were investigated: 1) a linear surrogate response surface (LIN) and 2) a quadratic response surface (QUAD). The LHS techniques do not require derivatives of the response variable and are subsequently relatively insensitive to numerical noise. To compare the LIN and QUAD methods to the MV method, a direct LHS analysis (DLHS) was performed using the full grid and timestep resolved finite element model. The surrogate response models (LIN and QUAD) are shown to give acceptable values of the mean and standard deviation when compared to the fully converged DLHS model.

  14. Sensitivity to Mental Effort and Test-Retest Reliability of Heart Rate Variability Measures in Healthy Seniors

    PubMed Central

    Mukherjee, Shalini; Yadav, Rajeev; Yung, Iris; Zajdel, Daniel P.; Oken, Barry S.

    2011-01-01

    Objectives To determine 1) whether heart rate variability (HRV) was a sensitive and reliable measure in mental effort tasks carried out by healthy seniors and 2) whether non-linear approaches to HRV analysis, in addition to traditional time and frequency domain approaches were useful to study such effects. Methods Forty healthy seniors performed two visual working memory tasks requiring different levels of mental effort, while ECG was recorded. They underwent the same tasks and recordings two weeks later. Traditional and 13 non-linear indices of HRV including Poincaré, entropy and detrended fluctuation analysis (DFA) were determined. Results Time domain (especially mean R-R interval/RRI), frequency domain and, among nonlinear parameters- Poincaré and DFA were the most reliable indices. Mean RRI, time domain and Poincaré were also the most sensitive to different mental effort task loads and had the largest effect size. Conclusions Overall, linear measures were the most sensitive and reliable indices to mental effort. In non-linear measures, Poincaré was the most reliable and sensitive, suggesting possible usefulness as an independent marker in cognitive function tasks in healthy seniors. Significance A large number of HRV parameters was both reliable as well as sensitive indices of mental effort, although the simple linear methods were the most sensitive. PMID:21459665

  15. Cardiothoracic ratio for prediction of left ventricular dilation: a systematic review and pooled analysis.

    PubMed

    Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit

    2015-03-01

    Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.

  16. [Enzymatic analysis of the quality of foodstuffs].

    PubMed

    Kolesnov, A Iu

    1997-01-01

    Enzymatic analysis is an independent and separate branch of enzymology and analytical chemistry. It has become one of the most important methodologies used in food analysis. Enzymatic analysis allows the quick, reliable determination of many food ingredients. Often these contents cannot be determined by conventional methods, or if methods are available, they are determined only with limited accuracy. Today, methods of enzymatic analysis are being increasingly used in the investigation of foodstuffs. Enzymatic measurement techniques are used in industry, scientific and food inspection laboratories for quality analysis. This article describes the requirements of an optimal analytical method: specificity, sample preparation, assay performance, precision, sensitivity, time requirement, analysis cost, safety of reagents.

  17. Sobol' sensitivity analysis for stressor impacts on honeybee ...

    EPA Pesticide Factsheets

    We employ Monte Carlo simulation and nonlinear sensitivity analysis techniques to describe the dynamics of a bee exposure model, VarroaPop. Daily simulations are performed of hive population trajectories, taking into account queen strength, foraging success, mite impacts, weather, colony resources, population structure, and other important variables. This allows us to test the effects of defined pesticide exposure scenarios versus controlled simulations that lack pesticide exposure. The daily resolution of the model also allows us to conditionally identify sensitivity metrics. We use the variancebased global decomposition sensitivity analysis method, Sobol’, to assess firstand secondorder parameter sensitivities within VarroaPop, allowing us to determine how variance in the output is attributed to each of the input variables across different exposure scenarios. Simulations with VarroaPop indicate queen strength, forager life span and pesticide toxicity parameters are consistent, critical inputs for colony dynamics. Further analysis also reveals that the relative importance of these parameters fluctuates throughout the simulation period according to the status of other inputs. Our preliminary results show that model variability is conditional and can be attributed to different parameters depending on different timescales. By using sensitivity analysis to assess model output and variability, calibrations of simulation models can be better informed to yield more

  18. Serum 25-hydroxyvitamin D and parathyroid hormone are independent determinants of whole-body insulin sensitivity in women and may contribute to lower insulin sensitivity in African Americans123

    PubMed Central

    Alvarez, Jessica A; Ashraf, Ambika P; Hunter, Gary R; Gower, Barbara A

    2010-01-01

    Background: Circulating 25-hydroxyvitamin D [25(OH)D] and parathyroid hormone (PTH) concentrations have been shown to be associated with insulin sensitivity; however, adiposity may confound this relation. Furthermore, African Americans (AAs) have lower insulin sensitivity and 25(OH)D concentrations than do European Americans (EAs); whether these differences are associated in a cause-and-effect manner has not been determined. Objectives: The objectives of this study were to examine the relation of 25(OH)D and PTH concentrations with whole-body insulin sensitivity and to determine whether lower 25(OH)D concentrations in AAs compared with EAs contribute to the lower insulin sensitivity of AAs relative to that of EAs. Design: This was a cross-sectional study of 25 AA and 25 EA women. We determined the whole-body insulin sensitivity index (SI) with an intravenous glucose tolerance test and minimal modeling. Percentage body fat was determined with dual-energy X-ray absorptiometry, and intraabdominal adipose tissue (IAAT) was determined with computed tomography. Results: Multiple linear regression analysis indicated that 25(OH)D and PTH concentrations were independent determinants of SI [standardized β = 0.24 (P = 0.04) and −0.36 (P = 0.002), respectively] after adjustment for age, race, and IAAT. The mean ethnic difference in SI decreased from 2.70 [· 10−4 · min−1/(μIU/mL)] after adjustment for IAAT and percentage body fat to 1.80 [· 10−4 · min−1/(μIU/mL)] after further adjustment for 25(OH)D and PTH concentrations. Conclusions: 25(OH)D and PTH concentrations were independently associated with whole-body insulin sensitivity in a cohort of healthy women, which suggested that these variables may influence insulin sensitivity through independent mechanisms. Furthermore, ethnic differences in 25(OH)D concentrations may contribute to ethnic differences in insulin sensitivity. PMID:20861177

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Stacy; English, Shawn; Briggs, Timothy

    Fiber-reinforced composite materials offer light-weight solutions to many structural challenges. In the development of high-performance composite structures, a thorough understanding is required of the composite materials themselves as well as methods for the analysis and failure prediction of the relevant composite structures. However, the mechanical properties required for the complete constitutive definition of a composite material can be difficult to determine through experimentation. Therefore, efficient methods are necessary that can be used to determine which properties are relevant to the analysis of a specific structure and to establish a structure's response to a material parameter that can only be definedmore » through estimation. The objectives of this paper deal with demonstrating the potential value of sensitivity and uncertainty quantification techniques during the failure analysis of loaded composite structures; and the proposed methods are applied to the simulation of the four-point flexural characterization of a carbon fiber composite material. Utilizing a recently implemented, phenomenological orthotropic material model that is capable of predicting progressive composite damage and failure, a sensitivity analysis is completed to establish which material parameters are truly relevant to a simulation's outcome. Then, a parameter study is completed to determine the effect of the relevant material properties' expected variations on the simulated four-point flexural behavior as well as to determine the value of an unknown material property. This process demonstrates the ability to formulate accurate predictions in the absence of a rigorous material characterization effort. Finally, the presented results indicate that a sensitivity analysis and parameter study can be used to streamline the material definition process as the described flexural characterization was used for model validation.« less

  20. Sensitivity analyses for simulating pesticide impacts on honey bee colonies

    USDA-ARS?s Scientific Manuscript database

    We employ Monte Carlo simulation and sensitivity analysis techniques to describe the population dynamics of pesticide exposure to a honey bee colony using the VarroaPop+Pesticide model. Simulations are performed of hive population trajectories with and without pesticide exposure to determine the eff...

  1. The mode of sensitization and its influence on allograft outcomes in highly sensitized kidney transplant recipients.

    PubMed

    Redfield, Robert R; Scalea, Joseph R; Zens, Tiffany J; Mandelbrot, Didier A; Leverson, Glen; Kaufman, Dixon B; Djamali, Arjang

    2016-10-01

    We sought to determine whether the mode of sensitization in highly sensitized patients contributed to kidney allograft survival. An analysis of the United Network for Organ Sharing dataset involving all kidney transplants between 1997 and 2014 was undertaken. Highly sensitized adult kidney transplant recipients [panel reactive antibody (PRA) ≥98%] were compared with adult, primary non-sensitized and re-transplant recipients. Kaplan-Meier survival analyses were used to determine allograft survival rates. Cox proportional hazards regression analyses were conducted to determine the association of graft loss with key predictors. Fifty-three percent of highly sensitized patients transplanted were re-transplants. Pregnancy and transfusion were the only sensitizing event in 20 and 5%, respectively. The 10-year actuarial graft survival for highly sensitized recipients was 43.9% compared with 52.4% for non-sensitized patients, P < 0.001. The combination of being highly sensitized by either pregnancy or blood transfusion increased the risk of graft loss by 23% [hazard ratio (HR) 1.230, confidence interval (CI) 1.150-1.315, P < 0.001], and the combination of being highly sensitized from a prior transplant increased the risk of graft loss by 58.1% (HR 1.581, CI 1.473-1.698, P < 0.001). The mode of sensitization predicts graft survival in highly sensitized kidney transplant recipients (PRA ≥98%). Patients who are highly sensitized from re-transplants have inferior graft survival compared with patients who are highly sensitized from other modes of sensitization. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hilfiker, James N.; Stadermann, Michael; Sun, Jianing

    It is a well-known challenge to determine refractive index (n) from ultra-thin films where the thickness is less than about 10 nm. In this paper, we discovered an interesting exception to this issue while characterizing spectroscopic ellipsometry (SE) data from isotropic, free-standing polymer films. Ellipsometry analysis shows that both thickness and refractive index can be independently determined for free-standing films as thin as 5 nm. Simulations further confirm an orthogonal separation between thickness and index effects on the experimental SE data. Effects of angle of incidence and wavelength on the data and sensitivity are discussed. Finally, while others have demonstratedmore » methods to determine refractive index from ultra-thin films, our analysis provides the first results to demonstrate high-sensitivity to the refractive index from ultra-thin layers.« less

  3. Composite laminate failure parameter optimization through four-point flexure experimentation and analysis

    DOE PAGES

    Nelson, Stacy; English, Shawn; Briggs, Timothy

    2016-05-06

    Fiber-reinforced composite materials offer light-weight solutions to many structural challenges. In the development of high-performance composite structures, a thorough understanding is required of the composite materials themselves as well as methods for the analysis and failure prediction of the relevant composite structures. However, the mechanical properties required for the complete constitutive definition of a composite material can be difficult to determine through experimentation. Therefore, efficient methods are necessary that can be used to determine which properties are relevant to the analysis of a specific structure and to establish a structure's response to a material parameter that can only be definedmore » through estimation. The objectives of this paper deal with demonstrating the potential value of sensitivity and uncertainty quantification techniques during the failure analysis of loaded composite structures; and the proposed methods are applied to the simulation of the four-point flexural characterization of a carbon fiber composite material. Utilizing a recently implemented, phenomenological orthotropic material model that is capable of predicting progressive composite damage and failure, a sensitivity analysis is completed to establish which material parameters are truly relevant to a simulation's outcome. Then, a parameter study is completed to determine the effect of the relevant material properties' expected variations on the simulated four-point flexural behavior as well as to determine the value of an unknown material property. This process demonstrates the ability to formulate accurate predictions in the absence of a rigorous material characterization effort. Finally, the presented results indicate that a sensitivity analysis and parameter study can be used to streamline the material definition process as the described flexural characterization was used for model validation.« less

  4. Gamma Ray Observatory (GRO) OBC attitude error analysis

    NASA Technical Reports Server (NTRS)

    Harman, R. R.

    1990-01-01

    This analysis involves an in-depth look into the onboard computer (OBC) attitude determination algorithm. A review of TRW error analysis and necessary ground simulations to understand the onboard attitude determination process are performed. In addition, a plan is generated for the in-flight calibration and validation of OBC computed attitudes. Pre-mission expected accuracies are summarized and sensitivity of onboard algorithms to sensor anomalies and filter tuning parameters are addressed.

  5. Determination of twenty-nine elements in eight argonne premium coal samples by instrumental neutron activation analysis

    USGS Publications Warehouse

    Palmer, C.A.

    1990-01-01

    Twenty-nine elements have been determined in triplicate splits of the eight Argonne National Laboratory Premium Coal Samples by instrumental neutron activtaion analysis. Data for control samples NBS 1633 (fly ash) and NBS 1632b are also reported. The factors that could lead to errors in analysis for these samples, such as spectral overlaps, low sensitivity, and interfering nuclear reactions, are discussed.

  6. Panoramic attitude sensor

    NASA Technical Reports Server (NTRS)

    Meek, I. C.

    1976-01-01

    Each subassembly, design analysis, and final calibration data on all assemblies for the Panormic Attitude Sensor (PAS) are described. The PAS is used for course attitude determination on the International Ultraviolet Explorer Spacecraft (IUE). The PAS contains a sun sensor which is sensitive only to the sun's radiation and a mechanically scanned sensor which is sensitive to the earth, moon, and the sun. The signals from these two sensors are encoded and sent back in the telemetry data stream to determine the spacecraft attitude.

  7. Space shuttle SRM plume expansion sensitivity analysis. [flow characteristics of exhaust gases from solid propellant rocket engines

    NASA Technical Reports Server (NTRS)

    Smith, S. D.; Tevepaugh, J. A.; Penny, M. M.

    1975-01-01

    The exhaust plumes of the space shuttle solid rocket motors can have a significant effect on the base pressure and base drag of the shuttle vehicle. A parametric analysis was conducted to assess the sensitivity of the initial plume expansion angle of analytical solid rocket motor flow fields to various analytical input parameters and operating conditions. The results of the analysis are presented and conclusions reached regarding the sensitivity of the initial plume expansion angle to each parameter investigated. Operating conditions parametrically varied were chamber pressure, nozzle inlet angle, nozzle throat radius of curvature ratio and propellant particle loading. Empirical particle parameters investigated were mean size, local drag coefficient and local heat transfer coefficient. Sensitivity of the initial plume expansion angle to gas thermochemistry model and local drag coefficient model assumptions were determined.

  8. PESTAN: Pesticide Analytical Model Version 4.0 User's Guide

    EPA Pesticide Factsheets

    The principal objective of this User's Guide to provide essential information on the aspects such as model conceptualization, model theory, assumptions and limitations, determination of input parameters, analysis of results and sensitivity analysis.

  9. No effect of bicarbonate treatment on insulin sensitivity and glucose control in non-diabetic older adults

    USDA-ARS?s Scientific Manuscript database

    Chronic mild metabolic acidosis is common among older adults, and limited evidence suggests that it may contribute to insulin resistance and type 2 diabetes. This analysis was conducted to determine whether bicarbonate supplementation, an alkalinizing treatment, improves insulin sensitivity or gluco...

  10. Sensitivity of grass and alfalfa reference evapotranspiration to weather station sensor accuracy

    USDA-ARS?s Scientific Manuscript database

    A sensitivity analysis was conducted to determine the relative effects of measurement errors in climate data input parameters on the accuracy of calculated reference crop evapotranspiration (ET) using the ASCE-EWRI Standardized Reference ET Equation. Data for the period of 1991 to 2008 from an autom...

  11. Sensitive sub-Doppler nonlinear spectroscopy for hyperfine-structure analysis using simple atomizers

    NASA Astrophysics Data System (ADS)

    Mickadeit, Fritz K.; Kemp, Helen; Schafer, Julia; Tong, William M.

    1998-05-01

    Laser wave-mixing spectroscopy is presented as a sub-Doppler method that offers not only high spectral resolution, but also excellent detection sensitivity. It offers spectral resolution suitable for hyperfine structure analysis and isotope ratio measurements. In a non-planar backward- scattering four-wave mixing optical configuration, two of the three input beams counter propagate and the Doppler broadening is minimized, and hence, spectral resolution is enhanced. Since the signal is a coherent beam, optical collection is efficient and signal detection is convenient. This simple multi-photon nonlinear laser method offers un usually sensitive detection limits that are suitable for trace-concentration isotope analysis using a few different types of simple analytical atomizers. Reliable measurement of hyperfine structures allows effective determination of isotope ratios for chemical analysis.

  12. A Most Probable Point-Based Method for Reliability Analysis, Sensitivity Analysis and Design Optimization

    NASA Technical Reports Server (NTRS)

    Hou, Gene J.-W; Newman, Perry A. (Technical Monitor)

    2004-01-01

    A major step in a most probable point (MPP)-based method for reliability analysis is to determine the MPP. This is usually accomplished by using an optimization search algorithm. The minimum distance associated with the MPP provides a measurement of safety probability, which can be obtained by approximate probability integration methods such as FORM or SORM. The reliability sensitivity equations are derived first in this paper, based on the derivatives of the optimal solution. Examples are provided later to demonstrate the use of these derivatives for better reliability analysis and reliability-based design optimization (RBDO).

  13. Indel analysis by droplet digital PCR: a sensitive method for DNA mixture detection and chimerism analysis.

    PubMed

    Santurtún, Ana; Riancho, José A; Arozamena, Jana; López-Duarte, Mónica; Zarrabeitia, María T

    2017-01-01

    Several methods have been developed to determinate genetic profiles from a mixed samples and chimerism analysis in transplanted patients. The aim of this study was to explore the effectiveness of using the droplet digital PCR (ddPCR) for mixed chimerism detection (a mixture of genetic profiles resulting after allogeneic hematopoietic stem cell transplantation (HSCT)). We analyzed 25 DNA samples from patients who had undergone HSCT and compared the performance of ddPCR and two established methods for chimerism detection, based upon the Indel and STRs analysis, respectively. Additionally, eight artificial mixture DNA samples were created to evaluate the sensibility of ddPCR. Our results show that the chimerism percentages estimated by the analysis of a single Indel using ddPCR were very similar to those calculated by the amplification of 15 STRs (r 2  = 0.970) and with the results obtained by the amplification of 38 Indels (r 2  = 0.975). Moreover, the amplification of a single Indel by ddPCR was sensitive enough to detect a minor DNA contributor comprising down to 0.5 % of the sample. We conclude that ddPCR can be a powerful tool for the determination of a genetic profile of forensic mixtures and clinical chimerism analysis when traditional techniques are not sensitive enough.

  14. Single-molecule detection: applications to ultrasensitive biochemical analysis

    NASA Astrophysics Data System (ADS)

    Castro, Alonso; Shera, E. Brooks

    1995-06-01

    Recent developments in laser-based detection of fluorescent molecules have made possible the implementation of very sensitive techniques for biochemical analysis. We present and discuss our experiments on the applications of our recently developed technique of single-molecule detection to the analysis of molecules of biological interest. These newly developed methods are capable of detecting and identifying biomolecules at the single-molecule level of sensitivity. In one case, identification is based on measuring fluorescence brightness from single molecules. In another, molecules are classified by determining their electrophoretic velocities.

  15. Performance sensitivity analysis of Department of Energy-Chrysler upgraded automotive gas turbine engine, S/N 5-4

    NASA Technical Reports Server (NTRS)

    Johnsen, R. L.

    1979-01-01

    The performance sensitivity of a two-shaft automotive gas turbine engine to changes in component performance and cycle operating parameters was examined. Sensitivities were determined for changes in turbomachinery efficiency, compressor inlet temperature, power turbine discharge temperature, regenerator effectiveness, regenerator pressure drop, and several gas flow and heat leaks. Compressor efficiency was found to have the greatest effect on system performance.

  16. A simple and sensitive method for determining plasma cell isotype and monoclonality in bone marrow using flowcytometry.

    PubMed

    van Zaanen, H C; Vet, R J; de Jong, C M; von dem Borne, A E; van Oers, M H

    1995-09-01

    In this paper we describe a new, rapid and sensitive method to determine plasma cell isotype and clonality in bone marrow using flowcytometry. With the use of a new fixation and permeabilization reagent (Permeafix), which preserves cell structure and morphology, and a monoclonal antibody (Mab) specific for plasma cells (B-B4), it has become possible to specifically select plasma cells and to determine the cytoplasmatic immunoglobulins by flowcytometry. Thirty successive bone marrow aspirates from multiple myeloma patients and patients with MGUS were studied as well as 10 bone marrow samples from patients with reactive plasmacytosis. Each sample was analysed both by immunofluorescence on cytospin smears and FACS analysis. There were no discrepancies between plasma cell isotype as determined by FACS and cytospin. Moreover, FACS analysis was shown to allow detection of very low numbers of plasma cells and to determine whether these plasma cells are mono- or polyclonal. Possible applications are discussed.

  17. Comparative efficacy of chloroquine and sulphadoxine--pyrimethamine in pregnant women and children: a meta-analysis.

    PubMed

    Kalanda, Gertrude C; Hill, Jenny; Verhoeff, Francine H; Brabin, Bernard J

    2006-05-01

    To compare the efficacy of chloroquine and sulphadoxine-pyremethamine against Plasmodium falciparum infection in pregnant women and in children from the same endemic areas of Africa, with the aim of determining the level of correspondence in efficacy determinations in these two risk groups. Meta-analysis of nine published and unpublished in vivo antimalarial efficacy studies in pregnant women and in children across five African countries. Pregnant women (all gravidae) were more likely to be sensitive than children to both chloroquine (odds ratio: 2.07; 95% confidence interval: 1.5, 2.9) and sulphadoxine-pyrimethamine (odds ratio: 2.66; 95% confidence interval: 11.1, 6.7). Pregnant women demonstrated an almost uniform increased sensitivity for peripheral parasite clearance at day 14 compared with children. This finding was consistent across a wide range of drug sensitivities. Primigravidae at day 14 showed lower clearance to antimalarial drugs than multigravidae (P<0.05). There was no significant difference between parasite clearance in primigravidae and in children. The greater drug sensitivity in pregnant women probably indicates differences in host susceptibility rather than parasite resistance. Parasite sensitivity patterns in children may be a suitable guide to antimalarial policy in pregnant women.

  18. Detection of Bladder CA by Microsatellite Analysis (MSA) — EDRN Public Portal

    Cancer.gov

    Goal 1: To determine sensitivity and specificity of microsatellite analysis (MSA) of urine sediment, using a panel of 15 microsatellite markers, in detecting bladder cancer in participants requiring cystoscopy. This technique will be compared to the diagnostic standard of cystoscopy, as well as to urine cytology. Goal 2: To determine the temporal performance characteristics of microsatellite analysis of urine sediment. Goal 3: To determine which of the 15 individual markers or combination of markers that make up the MSA test are most predictive of the presence of bladder cancer.

  19. Mid-L/D Lifting Body Entry Demise Analysis

    NASA Technical Reports Server (NTRS)

    Ling, Lisa

    2017-01-01

    The mid-lift-to-drag ratio (mid-L/D) lifting body is a fully autonomous spacecraft under design at NASA for enabling a rapid return of scientific payloads from the International Space Station (ISS). For contingency planning and risk assessment for the Earth-return trajectory, an entry demise analysis was performed to examine three potential failure scenarios: (1) nominal entry interface conditions with loss of control, (2) controlled entry at maximum flight path angle, and (3) controlled entry at minimum flight path angle. The objectives of the analysis were to predict the spacecraft breakup sequence and timeline, determine debris survival, and calculate the debris dispersion footprint. Sensitivity analysis was also performed to determine the effect of the initial pitch rate on the spacecraft stability and breakup during the entry. This report describes the mid-L/D lifting body and presents the results of the entry demise and sensitivity analyses.

  20. Sensitivity to mental effort and test-retest reliability of heart rate variability measures in healthy seniors.

    PubMed

    Mukherjee, Shalini; Yadav, Rajeev; Yung, Iris; Zajdel, Daniel P; Oken, Barry S

    2011-10-01

    To determine (1) whether heart rate variability (HRV) was a sensitive and reliable measure in mental effort tasks carried out by healthy seniors and (2) whether non-linear approaches to HRV analysis, in addition to traditional time and frequency domain approaches were useful to study such effects. Forty healthy seniors performed two visual working memory tasks requiring different levels of mental effort, while ECG was recorded. They underwent the same tasks and recordings 2 weeks later. Traditional and 13 non-linear indices of HRV including Poincaré, entropy and detrended fluctuation analysis (DFA) were determined. Time domain, especially mean R-R interval (RRI), frequency domain and, among non-linear parameters - Poincaré and DFA were the most reliable indices. Mean RRI, time domain and Poincaré were also the most sensitive to different mental effort task loads and had the largest effect size. Overall, linear measures were the most sensitive and reliable indices to mental effort. In non-linear measures, Poincaré was the most reliable and sensitive, suggesting possible usefulness as an independent marker in cognitive function tasks in healthy seniors. A large number of HRV parameters was both reliable as well as sensitive indices of mental effort, although the simple linear methods were the most sensitive. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Addressing Curse of Dimensionality in Sensitivity Analysis: How Can We Handle High-Dimensional Problems?

    NASA Astrophysics Data System (ADS)

    Safaei, S.; Haghnegahdar, A.; Razavi, S.

    2016-12-01

    Complex environmental models are now the primary tool to inform decision makers for the current or future management of environmental resources under the climate and environmental changes. These complex models often contain a large number of parameters that need to be determined by a computationally intensive calibration procedure. Sensitivity analysis (SA) is a very useful tool that not only allows for understanding the model behavior, but also helps in reducing the number of calibration parameters by identifying unimportant ones. The issue is that most global sensitivity techniques are highly computationally demanding themselves for generating robust and stable sensitivity metrics over the entire model response surface. Recently, a novel global sensitivity analysis method, Variogram Analysis of Response Surfaces (VARS), is introduced that can efficiently provide a comprehensive assessment of global sensitivity using the Variogram concept. In this work, we aim to evaluate the effectiveness of this highly efficient GSA method in saving computational burden, when applied to systems with extra-large number of input factors ( 100). We use a test function and a hydrological modelling case study to demonstrate the capability of VARS method in reducing problem dimensionality by identifying important vs unimportant input factors.

  2. Elastic critical moment for bisymmetric steel profiles and its sensitivity by the finite difference method

    NASA Astrophysics Data System (ADS)

    Kamiński, M.; Supeł, Ł.

    2016-02-01

    It is widely known that lateral-torsional buckling of a member under bending and warping restraints of its cross-sections in the steel structures are crucial for estimation of their safety and durability. Although engineering codes for steel and aluminum structures support the designer with the additional analytical expressions depending even on the boundary conditions and internal forces diagrams, one may apply alternatively the traditional Finite Element or Finite Difference Methods (FEM, FDM) to determine the so-called critical moment representing this phenomenon. The principal purpose of this work is to compare three different ways of determination of critical moment, also in the context of structural sensitivity analysis with respect to the structural element length. Sensitivity gradients are determined by the use of both analytical and the central finite difference scheme here and contrasted also for analytical, FEM as well as FDM approaches. Computational study is provided for the entire family of the steel I- and H - beams available for the practitioners in this area, and is a basis for further stochastic reliability analysis as well as durability prediction including possible corrosion progress.

  3. Results of an integrated structure-control law design sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Gilbert, Michael G.

    1988-01-01

    Next generation air and space vehicle designs are driven by increased performance requirements, demanding a high level of design integration between traditionally separate design disciplines. Interdisciplinary analysis capabilities have been developed, for aeroservoelastic aircraft and large flexible spacecraft control for instance, but the requisite integrated design methods are only beginning to be developed. One integrated design method which has received attention is based on hierarchal problem decompositions, optimization, and design sensitivity analyses. This paper highlights a design sensitivity analysis method for Linear Quadratic Cost, Gaussian (LQG) optimal control laws, which predicts change in the optimal control law due to changes in fixed problem parameters using analytical sensitivity equations. Numerical results of a design sensitivity analysis for a realistic aeroservoelastic aircraft example are presented. In this example, the sensitivity of the optimally controlled aircraft's response to various problem formulation and physical aircraft parameters is determined. These results are used to predict the aircraft's new optimally controlled response if the parameter was to have some other nominal value during the control law design process. The sensitivity results are validated by recomputing the optimal control law for discrete variations in parameters, computing the new actual aircraft response, and comparing with the predicted response. These results show an improvement in sensitivity accuracy for integrated design purposes over methods which do not include changess in the optimal control law. Use of the analytical LQG sensitivity expressions is also shown to be more efficient that finite difference methods for the computation of the equivalent sensitivity information.

  4. Estimation of the sensitive volume for gravitational-wave source populations using weighted Monte Carlo integration

    NASA Astrophysics Data System (ADS)

    Tiwari, Vaibhav

    2018-07-01

    The population analysis and estimation of merger rates of compact binaries is one of the important topics in gravitational wave astronomy. The primary ingredient in these analyses is the population-averaged sensitive volume. Typically, sensitive volume, of a given search to a given simulated source population, is estimated by drawing signals from the population model and adding them to the detector data as injections. Subsequently injections, which are simulated gravitational waveforms, are searched for by the search pipelines and their signal-to-noise ratio (SNR) is determined. Sensitive volume is estimated, by using Monte-Carlo (MC) integration, from the total number of injections added to the data, the number of injections that cross a chosen threshold on SNR and the astrophysical volume in which the injections are placed. So far, only fixed population models have been used in the estimation of binary black holes (BBH) merger rates. However, as the scope of population analysis broaden in terms of the methodologies and source properties considered, due to an increase in the number of observed gravitational wave (GW) signals, the procedure will need to be repeated multiple times at a large computational cost. In this letter we address the problem by performing a weighted MC integration. We show how a single set of generic injections can be weighted to estimate the sensitive volume for multiple population models; thereby greatly reducing the computational cost. The weights in this MC integral are the ratios of the output probabilities, determined by the population model and standard cosmology, and the injection probability, determined by the distribution function of the generic injections. Unlike analytical/semi-analytical methods, which usually estimate sensitive volume using single detector sensitivity, the method is accurate within statistical errors, comes at no added cost and requires minimal computational resources.

  5. Group-type hydrocarbon standards for high-performance liquid chromatographic analysis of middistillate fuels

    NASA Technical Reports Server (NTRS)

    Otterson, D. A.; Seng, G. T.

    1984-01-01

    A new high-performance liquid chromatographic (HPLC) method for group-type analysis of middistillate fuels is described. It uses a refractive index detector and standards that are prepared by reacting a portion of the fuel sample with sulfuric acid. A complete analysis of a middistillate fuel for saturates and aromatics (including the preparation of the standard) requires about 15 min if standards for several fuels are prepared simultaneously. From model fuel studies, the method was found to be accurate to within 0.4 vol% saturates or aromatics, and provides a precision of + or - 0.4 vol%. Olefin determinations require an additional 15 min of analysis time. However, this determination is needed only for those fuels displaying a significant olefin response at 200 nm (obtained routinely during the saturated/aromatics analysis procedure). The olefin determination uses the responses of the olefins and the corresponding saturates, as well as the average value of their refractive index sensitivity ratios (1.1). Studied indicated that, although the relative error in the olefins result could reach 10 percent by using this average sensitivity ratio, it was 5 percent for the fuels used in this study. Olefin concentrations as low as 0.1 vol% have been determined using this method.

  6. The countermovement jump to monitor neuromuscular status: A meta-analysis.

    PubMed

    Claudino, João Gustavo; Cronin, John; Mezêncio, Bruno; McMaster, Daniel Travis; McGuigan, Michael; Tricoli, Valmor; Amadio, Alberto Carlos; Serrão, Julio Cerca

    2017-04-01

    The primary objective of this meta-analysis was to compare countermovement jump (CMJ) performance in studies that reported the highest value as opposed to average value for the purposes of monitoring neuromuscular status (i.e., fatigue and supercompensation). The secondary aim was to determine the sensitivity of the dependent variables. Systematic review with meta-analysis. The meta-analysis was conducted on the highest or average of a number of CMJ variables. Multiple literature searches were undertaken in Pubmed, Scopus, and Web of Science to identify articles utilizing CMJ to monitor training status. Effect sizes (ES) with 95% confidence interval (95% CI) were calculated using the mean and standard deviation of the pre- and post-testing data. The coefficient of variation (CV) with 95% CI was also calculated to assess the level of instability of each variable. Heterogeneity was assessed using a random-effects model. 151 articles were included providing a total of 531 ESs for the meta-analyses; 85.4% of articles used highest CMJ height, 13.2% used average and 1.3% used both when reporting changes in CMJ performance. Based on the meta-analysis, average CMJ height was more sensitive than highest CMJ height in detecting CMJ fatigue and supercompensation. Furthermore, other CMJ variables such as peak power, mean power, peak velocity, peak force, mean impulse, and power were sensitive in tracking the supercompensation effects of training. The average CMJ height was more sensitive than highest CMJ height in monitoring neuromuscular status; however, further investigation is needed to determine the sensitivity of other CMJ performance variables. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    NASA Technical Reports Server (NTRS)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  8. Spatial variability in sensitivity of reference crop ET to accuracy of climate data in the Texas High Plains

    USDA-ARS?s Scientific Manuscript database

    A detailed sensitivity analysis was conducted to determine the relative effects of measurement errors in climate data input parameters on the accuracy of calculated reference crop evapotranspiration (ET) using the ASCE-EWRI Standardized Reference ET Equation. Data for the period of 1995 to 2008, fro...

  9. Analytic uncertainty and sensitivity analysis of models with input correlations

    NASA Astrophysics Data System (ADS)

    Zhu, Yueying; Wang, Qiuping A.; Li, Wei; Cai, Xu

    2018-03-01

    Probabilistic uncertainty analysis is a common means of evaluating mathematical models. In mathematical modeling, the uncertainty in input variables is specified through distribution laws. Its contribution to the uncertainty in model response is usually analyzed by assuming that input variables are independent of each other. However, correlated parameters are often happened in practical applications. In the present paper, an analytic method is built for the uncertainty and sensitivity analysis of models in the presence of input correlations. With the method, it is straightforward to identify the importance of the independence and correlations of input variables in determining the model response. This allows one to decide whether or not the input correlations should be considered in practice. Numerical examples suggest the effectiveness and validation of our analytic method in the analysis of general models. A practical application of the method is also proposed to the uncertainty and sensitivity analysis of a deterministic HIV model.

  10. Dynamical Model of Drug Accumulation in Bacteria: Sensitivity Analysis and Experimentally Testable Predictions

    DOE PAGES

    Vesselinova, Neda; Alexandrov, Boian; Wall, Michael E.

    2016-11-08

    We present a dynamical model of drug accumulation in bacteria. The model captures key features in experimental time courses on ofloxacin accumulation: initial uptake; two-phase response; and long-term acclimation. In combination with experimental data, the model provides estimates of import and export rates in each phase, the time of entry into the second phase, and the decrease of internal drug during acclimation. Global sensitivity analysis, local sensitivity analysis, and Bayesian sensitivity analysis of the model provide information about the robustness of these estimates, and about the relative importance of different parameters in determining the features of the accumulation time coursesmore » in three different bacterial species: Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The results lead to experimentally testable predictions of the effects of membrane permeability, drug efflux and trapping (e.g., by DNA binding) on drug accumulation. A key prediction is that a sudden increase in ofloxacin accumulation in both E. coli and S. aureus is accompanied by a decrease in membrane permeability.« less

  11. Dynamical Model of Drug Accumulation in Bacteria: Sensitivity Analysis and Experimentally Testable Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vesselinova, Neda; Alexandrov, Boian; Wall, Michael E.

    We present a dynamical model of drug accumulation in bacteria. The model captures key features in experimental time courses on ofloxacin accumulation: initial uptake; two-phase response; and long-term acclimation. In combination with experimental data, the model provides estimates of import and export rates in each phase, the time of entry into the second phase, and the decrease of internal drug during acclimation. Global sensitivity analysis, local sensitivity analysis, and Bayesian sensitivity analysis of the model provide information about the robustness of these estimates, and about the relative importance of different parameters in determining the features of the accumulation time coursesmore » in three different bacterial species: Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa. The results lead to experimentally testable predictions of the effects of membrane permeability, drug efflux and trapping (e.g., by DNA binding) on drug accumulation. A key prediction is that a sudden increase in ofloxacin accumulation in both E. coli and S. aureus is accompanied by a decrease in membrane permeability.« less

  12. Cyst fluid analysis in the differential diagnosis of pancreatic cystic lesions: a pooled analysis.

    PubMed

    van der Waaij, Laurens A; van Dullemen, Hendrik M; Porte, Robert J

    2005-09-01

    Pancreatic cystic tumors commonly include serous cystadenoma (SCA), mucinous cystadenoma (MCA), and mucinous cystadenocarcinoma (MCAC). A differential diagnosis with pseudocysts (PC) can be difficult. Radiologic criteria are not reliable. The objective of the study is to investigate the value of cyst fluid analysis in the differential diagnosis of benign (SCA, PC) vs. premalignant or malignant (MCA, MCAC) lesions. A search in PubMed was performed with the search terms cyst, pancrea, and fluid. Articles about cyst fluid analysis of pancreatic lesions that contained the individual data of at least 7 patients were included in the study. Data of all individual patients were combined and were plotted in scatter grams. Cutoff levels were determined. Twelve studies were included, which comprised data of 450 patients. Cysts with an amylase concentration <250 U/L were SCA, MCA, or MCAC (sensitivity 44%, specificity 98%) and, thus, virtually excluded PC. A carcinoembryonic antigen (CEA) <5 ng/mL suggested a SCA or PC (sensitivity 50%, specificity 95%). A CEA >800 ng/mL strongly suggested MCA or MCAC (sensitivity 48%, specificity 98%). A carbohydrate-associated antigen (CA) 19-9 <37 U/mL strongly suggested PC or SCA (sensitivity 19%, specificity 98%). Cytologic examination revealed malignant cells in 48% of MCAC (n = 111). Most pancreatic cystic tumors should be resected without the need for cyst fluid analysis. However, in asymptomatic patients, in patients with an increased surgical risk, and, in patients in whom there is a diagnostic uncertainty about the presence of a PC, cyst fluid analysis helps to determine the optimal therapeutic strategy.

  13. Comparisons of Fatty Acid Taste Detection Thresholds in People Who Are Lean vs. Overweight or Obese: A Systematic Review and Meta-Analysis.

    PubMed

    Tucker, Robin M; Kaiser, Kathryn A; Parman, Mariel A; George, Brandon J; Allison, David B; Mattes, Richard D

    2017-01-01

    Given the increasing evidence that supports the ability of humans to taste non-esterified fatty acids (NEFA), recent studies have sought to determine if relationships exist between oral sensitivity to NEFA (measured as thresholds), food intake and obesity. Published findings suggest there is either no association or an inverse association. A systematic review and meta-analysis was conducted to determine if differences in fatty acid taste sensitivity or intensity ratings exist between individuals who are lean or obese. A total of 7 studies that reported measurement of taste sensations to non-esterified fatty acids by psychophysical methods (e.g.,studies using model systems rather than foods, detection thresholds as measured by a 3-alternative forced choice ascending methodology were included in the meta-analysis. Two other studies that measured intensity ratings to graded suprathreshold NEFA concentrations were evaluated qualitatively. No significant differences in fatty acid taste thresholds or intensity were observed. Thus, differences in fatty acid taste sensitivity do not appear to precede or result from obesity.

  14. Sensitivity and Uncertainty Analysis of the GFR MOX Fuel Subassembly

    NASA Astrophysics Data System (ADS)

    Lüley, J.; Vrban, B.; Čerba, Š.; Haščík, J.; Nečas, V.; Pelloni, S.

    2014-04-01

    We performed sensitivity and uncertainty analysis as well as benchmark similarity assessment of the MOX fuel subassembly designed for the Gas-Cooled Fast Reactor (GFR) as a representative material of the core. Material composition was defined for each assembly ring separately allowing us to decompose the sensitivities not only for isotopes and reactions but also for spatial regions. This approach was confirmed by direct perturbation calculations for chosen materials and isotopes. Similarity assessment identified only ten partly comparable benchmark experiments that can be utilized in the field of GFR development. Based on the determined uncertainties, we also identified main contributors to the calculation bias.

  15. Optimized and validated flow-injection spectrophotometric analysis of topiramate, piracetam and levetiracetam in pharmaceutical formulations.

    PubMed

    Hadad, Ghada M; Abdel-Salam, Randa A; Emara, Samy

    2011-12-01

    Application of a sensitive and rapid flow injection analysis (FIA) method for determination of topiramate, piracetam, and levetiracetam in pharmaceutical formulations has been investigated. The method is based on the reaction with ortho-phtalaldehyde and 2-mercaptoethanol in a basic buffer and measurement of absorbance at 295 nm under flow conditions. Variables affecting the determination such as sample injection volume, pH, ionic strength, reagent concentrations, flow rate of reagent and other FIA parameters were optimized to produce the most sensitive and reproducible results using a quarter-fraction factorial design, for five factors at two levels. Also, the method has been optimized and fully validated in terms of linearity and range, limit of detection and quantitation, precision, selectivity and accuracy. The method was successfully applied to the analysis of pharmaceutical preparations.

  16. Computer-Aided Design/Manufacturing (CAD/M) for High-Speed Interconnect.

    DTIC Science & Technology

    1981-10-01

    are frequency sensitive and hence lend themselves to frequency domain ananlysis . Most of the classical microwave analysis is handled in the frequency ...capability integrated into a time-domain analysis program. This approach allows determination of frequency -dependent transmission line (interconnect...the items to consider in any interconnect study is that of the frequency range of interest. This determines whether the interconnections must be treated

  17. Descriptive analysis of the masticatory and salivary functions and gustatory sensitivity in healthy children.

    PubMed

    Marquezin, Maria Carolina Salomé; Pedroni-Pereira, Aline; Araujo, Darlle Santos; Rosar, João Vicente; Barbosa, Taís S; Castelo, Paula Midori

    2016-08-01

    The objective of this study is to better understand salivary and masticatory characteristics, this study evaluated the relationship among salivary parameters, bite force (BF), masticatory performance (MP) and gustatory sensitivity in healthy children. The secondary outcome was to evaluate possible gender differences. One hundred and sixteen eutrophic subjects aged 7-11 years old were evaluated, caries-free and with no definite need of orthodontic treatment. Salivary flow rate and pH, total protein (TP), alpha-amylase (AMY), calcium (CA) and phosphate (PHO) concentrations were determined in stimulated (SS) and unstimulated saliva (US). BF and MP were evaluated using digital gnathodynamometer and fractional sieving method, respectively. Gustatory sensitivity was determined by detecting the four primary tastes (sweet, salty, sour and bitter) in three different concentrations. Data were evaluated using descriptive statistics, Mann-Whitney/t-test, Spearman correlation and multiple regression analysis, considering α = 0.05. Significant positive correlation between taste and age was observed. CA and PHO concentrations correlated negatively with salivary flow and pH; sweet taste scores correlated with AMY concentrations and bitter taste sensitivity correlated with US flow rate (p < 0.05). No significant difference between genders in salivary, masticatory characteristics and gustatory sensitivity was observed. The regression analysis showed a weak relationship between the distribution of chewed particles among the different sieves and BF. The concentration of some analytes was influenced by salivary flow and pH. Age, saliva flow and AMY concentrations influenced gustatory sensitivity. In addition, salivary, masticatory and taste characteristics did not differ between genders, and only a weak relation between MP and BF was observed.

  18. Development of a highly sensitive and specific ELISA method for the determination of l-corydalmine in SD rats with monoclonal antibody.

    PubMed

    Zhang, Hongwei; Gao, Lan; Shu, Menglin; Liu, Jihua; Yu, Boyang

    2018-01-15

    l-Corydalmine (l-CDL) is a potent analgesic constituent of the traditional Chinese medicine, Rhizoma Corydalis. However, the pharmacokinetic process and tissue distribution of l-CDL in vivo are still unknown. Therefore, it is necessary to establish a simple and sensitive method to detect l-CDL, which will be helpful to study its distribution and pharmacokinetic process. To determine this compound in biological samples, a monoclonal antibody (mAb) against l-CDL was produced and a fast and highly sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed in this study. The icELISA was applied to determine l-CDL in biological samples. The limit of detection (LOD) of the method was 0.015 ng/mL with a liner range of 1-1000 ng/mL (R 2  = 0.9912). The intra- and inter-day precision were below 15% and the recoveries were within 80-117%. Finally, the developed immunoassay was successfully applied to the analysis of the distribution of l-CDL in SD rats. In conclusion, the icELISA based on the anti-l-CDL mAb could be considered as a highly sensitive and rapid method for the determination of l-CDL in biological samples. The ELISA approach may provide a valuable tool for the analysis of small molecules in biological samples. Copyright © 2017. Published by Elsevier B.V.

  19. Using the Mount Pinatubo Volcanic Eruption to Determine Climate Sensitivity: Comments on "Climate Forcing by the Volcanic Eruption of Mount Pinatubo" by David H. Douglass and Robert S. Knox

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wigley, T L; Ammann, C M; Santer, B D

    2005-04-22

    [1] Douglass and Knox [2005], hereafter referred to as DK, present an analysis of the observed cooling following the 1991 Mt. Pinatubo eruption and claim that these data imply a very low value for the climate sensitivity (equivalent to 0.6 C equilibrium warming for a CO{sub 2} doubling). We show here that their analysis is flawed and their results are incorrect.

  20. Dynamic analysis of Apollo-Salyut/Soyuz docking

    NASA Technical Reports Server (NTRS)

    Schliesing, J. A.

    1972-01-01

    The use of a docking-system computer program in analyzing the dynamic environment produced by two impacting spacecraft and the attitude control systems is discussed. Performance studies were conducted to determine the mechanism load and capture sensitivity to parametric changes in the initial impact conditions. As indicated by the studies, capture latching is most sensitive to vehicle angular-alinement errors and is least sensitive to lateral-miss error. As proved by load-sensitivity studies, peak loads acting on the Apollo spacecraft are considerably lower than the Apollo design-limit loads.

  1. Extrachromosomal inheritance in Schizosaccharomyces pombe. I. Evidence for an extrakaryotically inherited mutation conferring resistance to antimycin.

    PubMed

    Wolf, K; Burger, G; Lang, B; Kaudewitz, F

    1976-02-27

    In crosses of [ANTr8] with auxotrophic strains, resistance to antimycin segregates almost 50:50 in random spore analysis with a slight preponderance for the sensitivity allele. Tetrad analysis, however, shows all possible types of tetrads (2:2; 3:1; 1:3; 4:0; 0:4 resistant versus sensitive) with an excess of 2:2 segregations and sectoring of colonies on antimycin medium indicating an extrachromosomal mode of inheritance. The overall ratio of resistant versus sensitive spores is the same as compared with random spore data. Using a mutant blocked in meiosis (mei 1) mitotic segregation of stable diploids is achieved, leading to a ratio of 20% resistant to 80% sensitive clones. Possible reasons for the bias in transmission of the resistance determinant is discussed.

  2. Highly sensitive protein detection by biospecific AFM-based fishing with pulsed electrical stimulation.

    PubMed

    Pleshakova, Tatyana O; Malsagova, Kristina A; Kaysheva, Anna L; Kopylov, Arthur T; Tatur, Vadim Yu; Ziborov, Vadim S; Kanashenko, Sergey L; Galiullin, Rafael A; Ivanov, Yuri D

    2017-08-01

    We report here the highly sensitive detection of protein in solution at concentrations from 10 -15 to 10 -18 m using the combination of atomic force microscopy (AFM) and mass spectrometry. Biospecific detection of biotinylated bovine serum albumin was carried out by fishing out the protein onto the surface of AFM chips with immobilized avidin, which determined the specificity of the analysis. Electrical stimulation was applied to enhance the fishing efficiency. A high sensitivity of detection was achieved by application of nanosecond electric pulses to highly oriented pyrolytic graphite placed under the AFM chip. A peristaltic pump-based flow system, which is widely used in routine bioanalytical assays, was employed throughout the analysis. These results hold promise for the development of highly sensitive protein detection methods using nanosensor devices.

  3. Space transportation architecture: Reliability sensitivities

    NASA Technical Reports Server (NTRS)

    Williams, A. M.

    1992-01-01

    A sensitivity analysis is given of the benefits and drawbacks associated with a proposed Earth to orbit vehicle architecture. The architecture represents a fleet of six vehicles (two existing, four proposed) that would be responsible for performing various missions as mandated by NASA and the U.S. Air Force. Each vehicle has a prescribed flight rate per year for a period of 31 years. By exposing this fleet of vehicles to a probabilistic environment where the fleet experiences failures, downtimes, setbacks, etc., the analysis involves determining the resiliency and costs associated with the fleet of specific vehicle/subsystem reliabilities. The resources required were actual observed data on the failures and downtimes associated with existing vehicles, data based on engineering judgement for proposed vehicles, and the development of a sensitivity analysis program.

  4. Simultaneous Determination of Eight Hypotensive Drugs of Various Chemical Groups in Pharmaceutical Preparations by HPLC-DAD.

    PubMed

    Stolarczyk, Mariusz; Hubicka, Urszula; Żuromska-Witek, Barbara; Krzek, Jan

    2015-01-01

    A new sensitive, simple, rapid, and precise HPLC method with diode array detection has been developed for separation and simultaneous determination of hydrochlorothiazide, furosemide, torasemide, losartane, quinapril, valsartan, spironolactone, and canrenone in combined pharmaceutical dosage forms. The chromatographic analysis of the tested drugs was performed on an ACE C18, 100 Å, 250×4.6 mm, 5 μm particle size column with 0.0.05 M phosphate buffer (pH=3.00)-acetonitrile-methanol (30+20+50 v/v/v) mobile phase at a flow rate of 1.0 mL/min. The column was thermostatted at 25°C. UV detection was performed at 230 nm. Analysis time was 10 min. The elaborated method meets the acceptance criteria for specificity, linearity, sensitivity, accuracy, and precision. The proposed method was successfully applied for the determination of the studied drugs in the selected combined dosage forms.

  5. Rapid and sensitive analysis of phthalate metabolites, bisphenol A, and endogenous steroid hormones in human urine by mixed-mode solid-phase extraction, dansylation, and ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry.

    PubMed

    Wang, He-xing; Wang, Bin; Zhou, Ying; Jiang, Qing-wu

    2013-05-01

    Steroid hormone levels in human urine are convenient and sensitive indicators for the impact of phthalates and/or bisphenol A (BPA) exposure on the human steroid hormone endocrine system. In this study, a rapid and sensitive method for determination of 14 phthalate metabolites, BPA, and ten endogenous steroid hormones in urine was developed and validated on the basis of ultra-performance liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry. The optimized mixed-mode solid phase-extraction separated the weakly acidic or neutral BPA and steroid hormones from acidic phthalate metabolites in urine: the former were determined in positive ion mode with a methanol/water mobile phase containing 10 mM ammonium formate; the latter were determined in negative ion mode with a acetonitrile/water mobile phase containing 0.1 % acetic acid, which significantly alleviated matrix effects for the analysis of BPA and steroid hormones. Dansylation of estrogens and BPA realized simultaneous and sensitive analysis of the endogenous steroid hormones and BPA in a single chromatographic run. The limits of detection were less than 0.84 ng/mL for phthalate metabolites and less than 0.22 ng/mL for endogenous steroid hormones and BPA. This proposed method had satisfactory precision and accuracy, and was successfully applied to the analyses of human urine samples. This method could be valuable when investigating the associations among endocrine-disrupting chemicals, endogenous steroid hormones, and relevant adverse outcomes in epidemiological studies.

  6. [Quantitative surface analysis of Pt-Co, Cu-Au and Cu-Ag alloy films by XPS and AES].

    PubMed

    Li, Lian-Zhong; Zhuo, Shang-Jun; Shen, Ru-Xiang; Qian, Rong; Gao, Jie

    2013-11-01

    In order to improve the quantitative analysis accuracy of AES, We associated XPS with AES and studied the method to reduce the error of AES quantitative analysis, selected Pt-Co, Cu-Au and Cu-Ag binary alloy thin-films as the samples, used XPS to correct AES quantitative analysis results by changing the auger sensitivity factors to make their quantitative analysis results more similar. Then we verified the accuracy of the quantitative analysis of AES when using the revised sensitivity factors by other samples with different composition ratio, and the results showed that the corrected relative sensitivity factors can reduce the error in quantitative analysis of AES to less than 10%. Peak defining is difficult in the form of the integral spectrum of AES analysis since choosing the starting point and ending point when determining the characteristic auger peak intensity area with great uncertainty, and to make analysis easier, we also processed data in the form of the differential spectrum, made quantitative analysis on the basis of peak to peak height instead of peak area, corrected the relative sensitivity factors, and verified the accuracy of quantitative analysis by the other samples with different composition ratio. The result showed that the analytical error in quantitative analysis of AES reduced to less than 9%. It showed that the accuracy of AES quantitative analysis can be highly improved by the way of associating XPS with AES to correct the auger sensitivity factors since the matrix effects are taken into account. Good consistency was presented, proving the feasibility of this method.

  7. Probabilistic Structural Evaluation of Uncertainties in Radiator Sandwich Panel Design

    NASA Technical Reports Server (NTRS)

    Kuguoglu, Latife; Ludwiczak, Damian

    2006-01-01

    The Jupiter Icy Moons Orbiter (JIMO) Space System is part of the NASA's Prometheus Program. As part of the JIMO engineering team at NASA Glenn Research Center, the structural design of the JIMO Heat Rejection Subsystem (HRS) is evaluated. An initial goal of this study was to perform sensitivity analyses to determine the relative importance of the input variables on the structural responses of the radiator panel. The desire was to let the sensitivity analysis information identify the important parameters. The probabilistic analysis methods illustrated here support this objective. The probabilistic structural performance evaluation of a HRS radiator sandwich panel was performed. The radiator panel structural performance was assessed in the presence of uncertainties in the loading, fabrication process variables, and material properties. The stress and displacement contours of the deterministic structural analysis at mean probability was performed and results presented. It is followed by a probabilistic evaluation to determine the effect of the primitive variables on the radiator panel structural performance. Based on uncertainties in material properties, structural geometry and loading, the results of the displacement and stress analysis are used as an input file for the probabilistic analysis of the panel. The sensitivity of the structural responses, such as maximum displacement and maximum tensile and compressive stresses of the facesheet in x and y directions and maximum VonMises stresses of the tube, to the loading and design variables is determined under the boundary condition where all edges of the radiator panel are pinned. Based on this study, design critical material and geometric parameters of the considered sandwich panel are identified.

  8. Systematic review and meta-analysis of the performance of clinical risk assessment instruments for screening for osteoporosis or low bone density

    PubMed Central

    Edwards, D. L.; Saleh, A. A.; Greenspan, S. L.

    2015-01-01

    Summary We performed a systematic review and meta-analysis of the performance of clinical risk assessment instruments for screening for DXA-determined osteoporosis or low bone density. Commonly evaluated risk instruments showed high sensitivity approaching or exceeding 90 % at particular thresholds within various populations but low specificity at thresholds required for high sensitivity. Simpler instruments, such as OST, generally performed as well as or better than more complex instruments. Introduction The purpose of the study is to systematically review the performance of clinical risk assessment instruments for screening for dual-energy X-ray absorptiometry (DXA)-determined osteoporosis or low bone density. Methods Systematic review and meta-analysis were performed. Multiple literature sources were searched, and data extracted and analyzed from included references. Results One hundred eight references met inclusion criteria. Studies assessed many instruments in 34 countries, most commonly the Osteoporosis Self-Assessment Tool (OST), the Simple Calculated Osteoporosis Risk Estimation (SCORE) instrument, the Osteoporosis Self-Assessment Tool for Asians (OSTA), the Osteoporosis Risk Assessment Instrument (ORAI), and body weight criteria. Meta-analyses of studies evaluating OST using a cutoff threshold of <1 to identify US postmenopausal women with osteoporosis at the femoral neck provided summary sensitivity and specificity estimates of 89 % (95%CI 82–96 %) and 41 % (95%CI 23–59 %), respectively. Meta-analyses of studies evaluating OST using a cutoff threshold of 3 to identify US men with osteoporosis at the femoral neck, total hip, or lumbar spine provided summary sensitivity and specificity estimates of 88 % (95%CI 79–97 %) and 55 % (95%CI 42–68 %), respectively. Frequently evaluated instruments each had thresholds and populations for which sensitivity for osteoporosis or low bone mass detection approached or exceeded 90 % but always with a trade-off of relatively low specificity. Conclusions Commonly evaluated clinical risk assessment instruments each showed high sensitivity approaching or exceeding 90 % for identifying individuals with DXA-determined osteoporosis or low BMD at certain thresholds in different populations but low specificity at thresholds required for high sensitivity. Simpler instruments, such as OST, generally performed as well as or better than more complex instruments. PMID:25644147

  9. Computing the sensitivity of drag and lift in flow past a circular cylinder: Time-stepping versus self-consistent analysis

    NASA Astrophysics Data System (ADS)

    Meliga, Philippe

    2017-07-01

    We provide in-depth scrutiny of two methods making use of adjoint-based gradients to compute the sensitivity of drag in the two-dimensional, periodic flow past a circular cylinder (Re≲189 ): first, the time-stepping analysis used in Meliga et al. [Phys. Fluids 26, 104101 (2014), 10.1063/1.4896941] that relies on classical Navier-Stokes modeling and determines the sensitivity to any generic control force from time-dependent adjoint equations marched backwards in time; and, second, a self-consistent approach building on the model of Mantič-Lugo et al. [Phys. Rev. Lett. 113, 084501 (2014), 10.1103/PhysRevLett.113.084501] to compute semilinear approximations of the sensitivity to the mean and fluctuating components of the force. Both approaches are applied to open-loop control by a small secondary cylinder and allow identifying the sensitive regions without knowledge of the controlled states. The theoretical predictions obtained by time-stepping analysis reproduce well the results obtained by direct numerical simulation of the two-cylinder system. So do the predictions obtained by self-consistent analysis, which corroborates the relevance of the approach as a guideline for efficient and systematic control design in the attempt to reduce drag, even though the Reynolds number is not close to the instability threshold and the oscillation amplitude is not small. This is because, unlike simpler approaches relying on linear stability analysis to predict the main features of the flow unsteadiness, the semilinear framework encompasses rigorously the effect of the control on the mean flow, as well as on the finite-amplitude fluctuation that feeds back nonlinearly onto the mean flow via the formation of Reynolds stresses. Such results are especially promising as the self-consistent approach determines the sensitivity from time-independent equations that can be solved iteratively, which makes it generally less computationally demanding. We ultimately discuss the extent to which relevant information can be gained from a hybrid modeling computing self-consistent sensitivities from the postprocessing of DNS data. Application to alternative control objectives such as increasing the lift and alleviating the fluctuating drag and lift is also discussed.

  10. A preliminary study applying decision analysis to the treatment of caries in primary teeth.

    PubMed

    Tamošiūnas, Vytautas; Kay, Elizabeth; Craven, Rebecca

    2013-01-01

    To determine an optimal treatment strategy for carious deciduous teeth. Manchester Dental Hospital. Decision analysis. The likelihoods of each of the sequelae of caries in deciduous teeth were determined from the literature. The utility of the outcomes from non-treatment and treatment was then measured in 100 parents of children with caries, using a visual analogue scale. Decision analysis was performed which weighted the value of each potential outcome by the probability of its occurrence. A decision tree "fold-back" and sensitivity analysis then determined which treatment strategies, under which circumstances, offered the maximum expected utilities. The decision to leave a carious deciduous tooth unrestored attracted a maximum utility of 76.65 and the overall expected utility for the decision "restore" was 73.27 The decision to restore or not restore carious deciduous teeth are therefore of almost equal value. The decision is however highly sensitive to the utility value assigned to the advent of pain by the patient. There is no clear advantage to be gained by restoring deciduous teeth if patients' evaluations of outcomes are taken into account. Avoidance of pain and avoidance of procedures which are viewed as unpleasant by parents should be key determinants of clinical decision making about carious deciduous teeth.

  11. Isolation of a Moderately Stable but Sensitive Zwitterionic Diazonium Tetrazolyl-1,2,3-triazolate.

    PubMed

    Klapötke, Thomas M; Krumm, Burkhard; Pflüger, Carolin

    2016-07-15

    An unexpected formation of a diazonium compound was observed by nitration of an amino substituted triazolyl tetrazole with mixed acid. The crystal structure determination revealed a zwitterionic diazonium tetrazolyl-1,2,3-triazolate, whose constitution was supported by NMR and vibrational spectroscopic analysis. The thermal stability and sensitivity toward impact and friction were determined. In contrast, diazotriazoles are rather unstable and are mainly handled in solution and/or low temperatures, which is not the case for this diazonium tetrazolyl-1,2,3-triazolate, being stable at ambient temperature.

  12. Pain sensitivity profiles in patients with advanced knee osteoarthritis

    PubMed Central

    Frey-Law, Laura A.; Bohr, Nicole L.; Sluka, Kathleen A.; Herr, Keela; Clark, Charles R.; Noiseux, Nicolas O.; Callaghan, John J; Zimmerman, M Bridget; Rakel, Barbara A.

    2016-01-01

    The development of patient profiles to subgroup individuals on a variety of variables has gained attention as a potential means to better inform clinical decision-making. Patterns of pain sensitivity response specific to quantitative sensory testing (QST) modality have been demonstrated in healthy subjects. It has not been determined if these patterns persist in a knee osteoarthritis population. In a sample of 218 participants, 19 QST measures along with pain, psychological factors, self-reported function, and quality of life were assessed prior to total knee arthroplasty. Component analysis was used to identify commonalities across the 19 QST assessments to produce standardized pain sensitivity factors. Cluster analysis then grouped individuals that exhibited similar patterns of standardized pain sensitivity component scores. The QST resulted in four pain sensitivity components: heat, punctate, temporal summation, and pressure. Cluster analysis resulted in five pain sensitivity profiles: a “low pressure pain” group, an “average pain” group, and three “high pain” sensitivity groups who were sensitive to different modalities (punctate, heat, and temporal summation). Pain and function differed between pain sensitivity profiles, along with sex distribution; however no differences in OA grade, medication use, or psychological traits were found. Residualizing QST data by age and sex resulted in similar components and pain sensitivity profiles. Further, these profiles are surprisingly similar to those reported in healthy populations suggesting that individual differences in pain sensitivity are a robust finding even in an older population with significant disease. PMID:27152688

  13. Analysis of world terror networks from the reduced Google matrix of Wikipedia

    NASA Astrophysics Data System (ADS)

    El Zant, Samer; Frahm, Klaus M.; Jaffrès-Runser, Katia; Shepelyansky, Dima L.

    2018-01-01

    We apply the reduced Google matrix method to analyze interactions between 95 terrorist groups and determine their relationships and influence on 64 world countries. This is done on the basis of the Google matrix of the English Wikipedia (2017) composed of 5 416 537 articles which accumulate a great part of global human knowledge. The reduced Google matrix takes into account the direct and hidden links between a selection of 159 nodes (articles) appearing due to all paths of a random surfer moving over the whole network. As a result we obtain the network structure of terrorist groups and their relations with selected countries including hidden indirect links. Using the sensitivity of PageRank to a weight variation of specific links we determine the geopolitical sensitivity and influence of specific terrorist groups on world countries. The world maps of the sensitivity of various countries to influence of specific terrorist groups are obtained. We argue that this approach can find useful application for more extensive and detailed data bases analysis.

  14. The effects of physical activity on impulsive choice: Influence of sensitivity to reinforcement amount and delay

    PubMed Central

    Strickland, Justin C.; Feinstein, Max A.; Lacy, Ryan T.; Smith, Mark A.

    2016-01-01

    Impulsive choice is a diagnostic feature and/or complicating factor for several psychological disorders and may be examined in the laboratory using delay-discounting procedures. Recent investigators have proposed using quantitative measures of analysis to examine the behavioral processes contributing to impulsive choice. The purpose of this study was to examine the effects of physical activity (i.e., wheel running) on impulsive choice in a single-response, discrete-trial procedure using two quantitative methods of analysis. To this end, rats were assigned to physical activity or sedentary groups and trained to respond in a delay-discounting procedure. In this procedure, one lever always produced one food pellet immediately, whereas a second lever produced three food pellets after a 0, 10, 20, 40, or 80-second delay. Estimates of sensitivity to reinforcement amount and sensitivity to reinforcement delay were determined using (1) a simple linear analysis and (2) an analysis of logarithmically transformed response ratios. Both analyses revealed that physical activity decreased sensitivity to reinforcement amount and sensitivity to reinforcement delay. These findings indicate that (1) physical activity has significant but functionally opposing effects on the behavioral processes that contribute to impulsive choice and (2) both quantitative methods of analysis are appropriate for use in single-response, discrete-trial procedures. PMID:26964905

  15. Intracellular flow cytometry may be combined with good quality and high sensitivity RT-qPCR analysis.

    PubMed

    Sandstedt, Mikael; Jonsson, Marianne; Asp, Julia; Dellgren, Göran; Lindahl, Anders; Jeppsson, Anders; Sandstedt, Joakim

    2015-12-01

    Flow cytometry (FCM) has become a well-established method for analysis of both intracellular and cell-surface proteins, while quantitative RT-PCR (RT-qPCR) is used to determine gene expression with high sensitivity and specificity. Combining these two methods would be of great value. The effects of intracellular staining on RNA integrity and RT-qPCR sensitivity and quality have not, however, been fully examined. We, therefore, intended to assess these effects further. Cells from the human lung cancer cell line A549 were fixed, permeabilized and sorted by FCM. Sorted cells were analyzed using RT-qPCR. RNA integrity was determined by RNA quality indicator analysis. A549 cells were then mixed with cells of the mouse cardiomyocyte cell line HL-1. A549 cells were identified by the cell surface marker ABCG2, while HL-1 cells were identified by intracellular cTnT. Cells were sorted and analyzed by RT-qPCR. Finally, cell cultures from human atrial biopsies were used to evaluate the effects of fixation and permeabilization on RT-qPCR analysis of nonimmortalized cells stored prior to analysis by FCM. A large amount of RNA could be extracted even when cells had been fixed and permeabilized. Permeabilization resulted in increased RNA degradation and a moderate decrease in RT-qPCR sensitivity. Gene expression levels were also affected to a moderate extent. Sorted populations from the mixed A549 and HL-1 cell samples showed gene expression patterns that corresponded to FCM data. When samples were stored before FCM sorting, the RT-qPCR analysis could still be performed with high sensitivity and quality. In summary, our results show that intracellular FCM may be performed with only minor impairment of the RT-qPCR sensitivity and quality when analyzing sorted cells; however, these effects should be considered when comparing RT-qPCR data of not fixed samples with those of fixed and permeabilized samples. © 2015 International Society for Advancement of Cytometry.

  16. A mixture theory model of fluid and solute transport in the microvasculature of normal and malignant tissues. II: Factor sensitivity analysis, calibration, and validation.

    PubMed

    Schuff, M M; Gore, J P; Nauman, E A

    2013-12-01

    The treatment of cancerous tumors is dependent upon the delivery of therapeutics through the blood by means of the microcirculation. Differences in the vasculature of normal and malignant tissues have been recognized, but it is not fully understood how these differences affect transport and the applicability of existing mathematical models has been questioned at the microscale due to the complex rheology of blood and fluid exchange with the tissue. In addition to determining an appropriate set of governing equations it is necessary to specify appropriate model parameters based on physiological data. To this end, a two stage sensitivity analysis is described which makes it possible to determine the set of parameters most important to the model's calibration. In the first stage, the fluid flow equations are examined and a sensitivity analysis is used to evaluate the importance of 11 different model parameters. Of these, only four substantially influence the intravascular axial flow providing a tractable set that could be calibrated using red blood cell velocity data from the literature. The second stage also utilizes a sensitivity analysis to evaluate the importance of 14 model parameters on extravascular flux. Of these, six exhibit high sensitivity and are integrated into the model calibration using a response surface methodology and experimental intra- and extravascular accumulation data from the literature (Dreher et al. in J Natl Cancer Inst 98(5):335-344, 2006). The model exhibits good agreement with the experimental results for both the mean extravascular concentration and the penetration depth as a function of time for inert dextran over a wide range of molecular weights.

  17. Sensitivity analysis in economic evaluation: an audit of NICE current practice and a review of its use and value in decision-making.

    PubMed

    Andronis, L; Barton, P; Bryan, S

    2009-06-01

    To determine how we define good practice in sensitivity analysis in general and probabilistic sensitivity analysis (PSA) in particular, and to what extent it has been adhered to in the independent economic evaluations undertaken for the National Institute for Health and Clinical Excellence (NICE) over recent years; to establish what policy impact sensitivity analysis has in the context of NICE, and policy-makers' views on sensitivity analysis and uncertainty, and what use is made of sensitivity analysis in policy decision-making. Three major electronic databases, MEDLINE, EMBASE and the NHS Economic Evaluation Database, were searched from inception to February 2008. The meaning of 'good practice' in the broad area of sensitivity analysis was explored through a review of the literature. An audit was undertaken of the 15 most recent NICE multiple technology appraisal judgements and their related reports to assess how sensitivity analysis has been undertaken by independent academic teams for NICE. A review of the policy and guidance documents issued by NICE aimed to assess the policy impact of the sensitivity analysis and the PSA in particular. Qualitative interview data from NICE Technology Appraisal Committee members, collected as part of an earlier study, were also analysed to assess the value attached to the sensitivity analysis components of the economic analyses conducted for NICE. All forms of sensitivity analysis, notably both deterministic and probabilistic approaches, have their supporters and their detractors. Practice in relation to univariate sensitivity analysis is highly variable, with considerable lack of clarity in relation to the methods used and the basis of the ranges employed. In relation to PSA, there is a high level of variability in the form of distribution used for similar parameters, and the justification for such choices is rarely given. Virtually all analyses failed to consider correlations within the PSA, and this is an area of concern. Uncertainty is considered explicitly in the process of arriving at a decision by the NICE Technology Appraisal Committee, and a correlation between high levels of uncertainty and negative decisions was indicated. The findings suggest considerable value in deterministic sensitivity analysis. Such analyses serve to highlight which model parameters are critical to driving a decision. Strong support was expressed for PSA, principally because it provides an indication of the parameter uncertainty around the incremental cost-effectiveness ratio. The review and the policy impact assessment focused exclusively on documentary evidence, excluding other sources that might have revealed further insights on this issue. In seeking to address parameter uncertainty, both deterministic and probabilistic sensitivity analyses should be used. It is evident that some cost-effectiveness work, especially around the sensitivity analysis components, represents a challenge in making it accessible to those making decisions. This speaks to the training agenda for those sitting on such decision-making bodies, and to the importance of clear presentation of analyses by the academic community.

  18. Examining the accuracy of the infinite order sudden approximation using sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Eno, Larry; Rabitz, Herschel

    1981-08-01

    A method is developed for assessing the accuracy of scattering observables calculated within the framework of the infinite order sudden (IOS) approximation. In particular, we focus on the energy sudden assumption of the IOS method and our approach involves the determination of the sensitivity of the IOS scattering matrix SIOS with respect to a parameter which reintroduces the internal energy operator ?0 into the IOS Hamiltonian. This procedure is an example of sensitivity analysis of missing model components (?0 in this case) in the reference Hamiltonian. In contrast to simple first-order perturbation theory a finite result is obtained for the effect of ?0 on SIOS. As an illustration, our method of analysis is applied to integral state-to-state cross sections for the scattering of an atom and rigid rotor. Results are generated within the He+H2 system and a comparison is made between IOS and coupled states cross sections and the corresponding IOS sensitivities. It is found that the sensitivity coefficients are very useful indicators of the accuracy of the IOS results. Finally, further developments and applications are discussed.

  19. Trace analysis of high-purity graphite by LA-ICP-MS.

    PubMed

    Pickhardt, C; Becker, J S

    2001-07-01

    Laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a very efficient and sensitive technique for the direct analysis of solids. In this work the capability of LA-ICP-MS was investigated for determination of trace elements in high-purity graphite. Synthetic laboratory standards with a graphite matrix were prepared for the purpose of quantifying the analytical results. Doped trace elements, concentration 0.5 microg g(-1), in a laboratory standard were determined with an accuracy of 1% to +/- 7% and a relative standard deviation (RSD) of 2-13%. Solution-based calibration was also used for quantitative analysis of high-purity graphite. It was found that such calibration led to analytical results for trace-element determination in graphite with accuracy similar to that obtained by use of synthetic laboratory standards for quantification of analytical results. Results from quantitative determination of trace impurities in a real reactor-graphite sample, using both quantification approaches, were in good agreement. Detection limits for all elements of interest were determined in the low ng g(-1) concentration range. Improvement of detection limits by a factor of 10 was achieved for analyses of high-purity graphite with LA-ICP-MS under wet plasma conditions, because the lower background signal and increased element sensitivity.

  20. Peri-muscular adipose tissue may play a unique role in determining insulin sensitivity/resistance in women with polycystic ovary syndrome.

    PubMed

    Morrison, Shannon A; Goss, Amy M; Azziz, Ricardo; Raju, Dheeraj A; Gower, Barbara A

    2017-01-01

    Do the determinants of insulin sensitivity/resistance differ in women with and without polycystic ovary syndrome (PCOS)? Peri-muscular thigh adipose tissue is uniquely associated with insulin sensitivity/resistance in women with PCOS, whereas adiponectin and thigh subcutaneous adipose are the main correlates of insulin sensitivity/resistance in women without PCOS. In subject populations without PCOS, insulin sensitivity/resistance is determined by body fat distribution and circulating concentrations of hormones and pro-inflammatory mediators. Specifically, visceral (intra-abdominal) adipose tissue mass is adversely associated with insulin sensitivity, whereas thigh subcutaneous adipose appears protective against metabolic disease. Adiponectin is an insulin-sensitizing hormone produced by healthy subcutaneous adipose that may mediate the protective effect of thigh subcutaneous adipose. Testosterone, which is elevated in PCOS, may have an adverse effect on insulin sensitivity/resistance. Cross-sectional study of 30 women with PCOS and 38 women without PCOS; data were collected between 2007 and 2011. Participants were group-matched for obesity, as reflected in BMI (Mean ± SD; PCOS: 31.8 ± 6.0 kg/m 2 ; without PCOS: 31.5 ± 5.0 kg/m 2 ). The whole-body insulin sensitivity index (WBISI) was assessed using a mixed-meal tolerance test; Homeostasis Model Assessment-Insulin resistance (HOMA-IR) was determined from fasting insulin and glucose values. Adipose tissue distribution was determined by computed tomography (CT) scan. Partial correlation analysis, adjusting for total fat mass, was used to identify correlates of WBISI and HOMA-IR within each group of women from measures of body composition, body fat distribution, reproductive-endocrine hormones and adipokines/cytokines. Stepwise multiple linear regression analysis was used to identify the variables that best predicted WBISI and HOMA-IR. Among women with PCOS, both WBISI and HOMA-IR were best predicted by peri-muscular adipose tissue cross-sectional area. Among women without PCOS, both WBISI and HOMA-IR were best predicted by adiponectin and thigh subcutaneous adipose tissue. Small sample size, group matching for BMI and age, and the use of surrogate measures of insulin sensitivity/resistance. Because insulin resistance is the root cause of obesity and comorbidities in PCOS, determining its cause could lead to potential therapies. Present results suggest that peri-muscular adipose tissue may play a unique role in determining insulin sensitivity/resistance in women with PCOS. Interventions such as restriction of dietary carbohydrates that have been shown to selectively reduce fatty infiltration of skeletal muscle may decrease the risk for type 2 diabetes in women with PCOS. The study was supported by National Institutes of Health grants R01HD054960, R01DK67538, P30DK56336, P60DK079626, M014RR00032 and UL1RR025777. The authors have no conflicts of interest. NCT00726908. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Resonance Rayleigh scattering method for highly sensitive detection of chitosan using aniline blue as probe

    NASA Astrophysics Data System (ADS)

    Zhang, Weiai; Ma, Caijuan; Su, Zhengquan; Bai, Yan

    2016-11-01

    This paper describes a highly sensitive and accurate approach using aniline blue (AB) (water soluble) as a probe to determine chitosan (CTS) through Resonance Rayleigh scattering (RRS). Under optimum experimental conditions, the intensities of RRS were linearly proportional to the concentration of CTS in the range from 0.01 to 3.5 μg/mL, and the limit of detection (LOD) was 6.94 ng/mL. Therefore, a new and highly sensitive method based on RRS for the determination of CTS has been developed. Furthermore, the effect of molecular weight of CTS and the effect of the degree of deacetylation of CTS on the accurate quantification of CTS was studied. The experimental data was analyzed by linear regression analysis, which indicated that the molecular weight and the degree of deacetylation of CTS had no statistical significance and this method could be used to determine CTS accurately. Meanwhile, this assay was applied for CTS determination in health products with satisfactory results.

  2. Sobol‧ sensitivity analysis of NAPL-contaminated aquifer remediation process based on multiple surrogates

    NASA Astrophysics Data System (ADS)

    Luo, Jiannan; Lu, Wenxi

    2014-06-01

    Sobol‧ sensitivity analyses based on different surrogates were performed on a trichloroethylene (TCE)-contaminated aquifer to assess the sensitivity of the design variables of remediation duration, surfactant concentration and injection rates at four wells to remediation efficiency First, the surrogate models of a multi-phase flow simulation model were constructed by applying radial basis function artificial neural network (RBFANN) and Kriging methods, and the two models were then compared. Based on the developed surrogate models, the Sobol‧ method was used to calculate the sensitivity indices of the design variables which affect the remediation efficiency. The coefficient of determination (R2) and the mean square error (MSE) of these two surrogate models demonstrated that both models had acceptable approximation accuracy, furthermore, the approximation accuracy of the Kriging model was slightly better than that of the RBFANN model. Sobol‧ sensitivity analysis results demonstrated that the remediation duration was the most important variable influencing remediation efficiency, followed by rates of injection at wells 1 and 3, while rates of injection at wells 2 and 4 and the surfactant concentration had negligible influence on remediation efficiency. In addition, high-order sensitivity indices were all smaller than 0.01, which indicates that interaction effects of these six factors were practically insignificant. The proposed Sobol‧ sensitivity analysis based on surrogate is an effective tool for calculating sensitivity indices, because it shows the relative contribution of the design variables (individuals and interactions) to the output performance variability with a limited number of runs of a computationally expensive simulation model. The sensitivity analysis results lay a foundation for the optimal groundwater remediation process optimization.

  3. CORSSTOL: Cylinder Optimization of Rings, Skin, and Stringers with Tolerance sensitivity

    NASA Technical Reports Server (NTRS)

    Finckenor, J.; Bevill, M.

    1995-01-01

    Cylinder Optimization of Rings, Skin, and Stringers with Tolerance (CORSSTOL) sensitivity is a design optimization program incorporating a method to examine the effects of user-provided manufacturing tolerances on weight and failure. CORSSTOL gives designers a tool to determine tolerances based on need. This is a decisive way to choose the best design among several manufacturing methods with differing capabilities and costs. CORSSTOL initially optimizes a stringer-stiffened cylinder for weight without tolerances. The skin and stringer geometry are varied, subject to stress and buckling constraints. Then the same analysis and optimization routines are used to minimize the maximum material condition weight subject to the least favorable combination of tolerances. The adjusted optimum dimensions are provided with the weight and constraint sensitivities of each design variable. The designer can immediately identify critical tolerances. The safety of parts made out of tolerance can also be determined. During design and development of weight-critical systems, design/analysis tools that provide product-oriented results are of vital significance. The development of this program and methodology provides designers with an effective cost- and weight-saving design tool. The tolerance sensitivity method can be applied to any system defined by a set of deterministic equations.

  4. Feasibility of determining flat roof heat losses using aerial thermography

    NASA Technical Reports Server (NTRS)

    Bowman, R. L.; Jack, J. R.

    1979-01-01

    The utility of aerial thermography for determining rooftop heat losses was investigated experimentally using several completely instrumented test roofs with known thermal resistances. Actual rooftop heat losses were obtained both from in-situ instrumentation and aerial thermography obtained from overflights at an altitude of 305 m. In general, the remotely determined roof surface temperatures agreed very well with those obtained from ground measurements. The roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from 1/R delta T using ground measurements. However, this agreement may be fortuitous since the convective component of the heat loss is sensitive to small changes in roof temperature and to the average heat transfer coefficient used, whereas the radiative component is less sensitive. This, at this time, it is felt that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. The sensitivity of the heat loss determination to environmental conditions was also evaluated. The analysis showed that the most reliable quantitative heat loss determinations can probably be obtained from aerial thermography taken under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

  5. Computing sensitivity and selectivity in parallel factor analysis and related multiway techniques: the need for further developments in net analyte signal theory.

    PubMed

    Olivieri, Alejandro C

    2005-08-01

    Sensitivity and selectivity are important figures of merit in multiway analysis, regularly employed for comparison of the analytical performance of methods and for experimental design and planning. They are especially interesting in the second-order advantage scenario, where the latter property allows for the analysis of samples with a complex background, permitting analyte determination even in the presence of unsuspected interferences. Since no general theory exists for estimating the multiway sensitivity, Monte Carlo numerical calculations have been developed for estimating variance inflation factors, as a convenient way of assessing both sensitivity and selectivity parameters for the popular parallel factor (PARAFAC) analysis and also for related multiway techniques. When the second-order advantage is achieved, the existing expressions derived from net analyte signal theory are only able to adequately cover cases where a single analyte is calibrated using second-order instrumental data. However, they fail for certain multianalyte cases, or when third-order data are employed, calling for an extension of net analyte theory. The results have strong implications in the planning of multiway analytical experiments.

  6. Sensitivity Analysis of Launch Vehicle Debris Risk Model

    NASA Technical Reports Server (NTRS)

    Gee, Ken; Lawrence, Scott L.

    2010-01-01

    As part of an analysis of the loss of crew risk associated with an ascent abort system for a manned launch vehicle, a model was developed to predict the impact risk of the debris resulting from an explosion of the launch vehicle on the crew module. The model consisted of a debris catalog describing the number, size and imparted velocity of each piece of debris, a method to compute the trajectories of the debris and a method to calculate the impact risk given the abort trajectory of the crew module. The model provided a point estimate of the strike probability as a function of the debris catalog, the time of abort and the delay time between the abort and destruction of the launch vehicle. A study was conducted to determine the sensitivity of the strike probability to the various model input parameters and to develop a response surface model for use in the sensitivity analysis of the overall ascent abort risk model. The results of the sensitivity analysis and the response surface model are presented in this paper.

  7. Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

  8. Sensitivity and specificity of indocyanine green near-infrared fluorescence imaging in detection of metastatic lymph nodes in colorectal cancer: Systematic review and meta-analysis.

    PubMed

    Emile, Sameh H; Elfeki, Hossam; Shalaby, Mostafa; Sakr, Ahmad; Sileri, Pierpaolo; Laurberg, Søren; Wexner, Steven D

    2017-11-01

    This review aimed to determine the overall sensitivity and specificity of indocyanine green (ICG) near-infrared (NIR) fluorescence in sentinel lymph node (SLN) detection in Colorectal cancer (CRC). A systematic search in electronic databases was conducted. Twelve studies including 248 patients were reviewed. The median sensitivity, specificity, and accuracy rates were 73.7, 100, and 75.7. The pooled sensitivity and specificity rates were 71% and 84.6%. In conclusion, ICG-NIR fluorescence is a promising technique for detecting SLNs in CRC. © 2017 Wiley Periodicals, Inc.

  9. Monte Carlo sensitivity analysis of unknown parameters in hazardous materials transportation risk assessment.

    PubMed

    Pet-Armacost, J J; Sepulveda, J; Sakude, M

    1999-12-01

    The US Department of Transportation was interested in the risks associated with transporting Hydrazine in tanks with and without relief devices. Hydrazine is both highly toxic and flammable, as well as corrosive. Consequently, there was a conflict as to whether a relief device should be used or not. Data were not available on the impact of relief devices on release probabilities or the impact of Hydrazine on the likelihood of fires and explosions. In this paper, a Monte Carlo sensitivity analysis of the unknown parameters was used to assess the risks associated with highway transport of Hydrazine. To help determine whether or not relief devices should be used, fault trees and event trees were used to model the sequences of events that could lead to adverse consequences during transport of Hydrazine. The event probabilities in the event trees were derived as functions of the parameters whose effects were not known. The impacts of these parameters on the risk of toxic exposures, fires, and explosions were analyzed through a Monte Carlo sensitivity analysis and analyzed statistically through an analysis of variance. The analysis allowed the determination of which of the unknown parameters had a significant impact on the risks. It also provided the necessary support to a critical transportation decision even though the values of several key parameters were not known.

  10. Human oesophagus: a convenient antigenic substrate for the determination of anti-endomysium antibodies in the serological diagnosis of coeliac disease.

    PubMed

    Uibo, O; Lambrechts, A; Mascart-Lemone, F

    1995-01-01

    Immunoglobulin (Ig) A-class anti-endomysium antibodies are superior to other current antibody tests for detecting coeliac disease. We aimed to evaluate the suitability of human oesophagus for the determination of anti-endomysium antibodies. The specificity of monkey and human oesophageal tissue as antigenic substrate were compared using indirect immunofluorescence analysis. Overall, 159 individuals were studied: 56 patients with biopsy-proven coeliac disease (39 with active disease) and 103 controls. The patients' IgA-class anti-endomysium antibodies were compared using unfixed cryostat sections of human and monkey oesophagus. Indirect immunofluorescence analysis was performed with an initial serum sample dilution of 1:5, and if positive, the highest dilution yielding a positive reaction was reported. The anti-endomysium antibody test was positive in 38 out of 39 patients with active coeliac disease using monkey oesophagus (sensitivity 97%) and in all 39 patients with active coeliac disease using human oesophagus (sensitivity 100%). Ten out of 17 coeliac patients on a gluten-free diet had positive anti-endomysium antibodies using monkey oesophagus and 12 using human oesophagus as the antigenic substrate. This test was negative in all 103 controls using both substrates. Our study shows that human oesophageal tissue can be used instead of monkey tissue for determining anti-endomysium antibodies. Human tissue is a more sensitive antigenic substrate than monkey oesophagus and can be used to determine low titres of antibodies. Improving the diagnostic sensitivity of the anti-endomysium antibody test would make an important contribution to screening for coeliac disease.

  11. A Quad-Cantilevered Plate micro-sensor for intracranial pressure measurement.

    PubMed

    Lalkov, Vasko; Qasaimeh, Mohammad A

    2017-07-01

    This paper proposes a new design for pressure-sensing micro-plate platform to bring higher sensitivity to a pressure sensor based on piezoresistive MEMS sensing mechanism. The proposed design is composed of a suspended plate having four stepped cantilever beams connected to its corners, and thus defined as Quad-Cantilevered Plate (QCP). Finite element analysis was performed to determine the optimal design for sensitivity and structural stability under a range of applied forces. Furthermore, a piezoresistive analysis was performed to calculate sensor sensitivity. Both the maximum stress and the change in resistance of the piezoresistor associated with the QCP were found to be higher compared to previously published designs, and linearly related to the applied pressure as desired. Therefore, the QCP demonstrates greater sensitivity, and could be potentially used as an efficient pressure sensor for intracranial pressure measurement.

  12. A Quantitative Study of Oxygen as a Metabolic Regulator

    NASA Technical Reports Server (NTRS)

    Radhakrishnan, Krishnan; LaManna, Joseph C.; Cabrera, Marco E.

    1999-01-01

    An acute reduction in oxygen (O2) delivery to a tissue is generally associated with a decrease in phosphocreatine, increases in ADP, NADH/NAD, and inorganic phosphate, increased rates of glycolysis and lactate production, and reduced rates of pyruvate and fatty acid oxidation. However, given the complexity of the human bioenergetic system and its components, it is difficult to determine quantitatively how cellular metabolic processes interact to maintain ATP homeostasis during stress (e.g., hypoxia, ischemia, and exercise). Of special interest is the determination of mechanisms relating tissue oxygenation to observed metabolic responses at the tissue, organ, and whole body levels and the quantification of how changes in tissue O2 availability affect the pathways of ATP synthesis and the metabolites that control these pathways. In this study, we extend a previously developed mathematical model of human bioenergetics to provide a physicochemical framework that permits quantitative understanding of O2 as a metabolic regulator. Specifically, the enhancement permits studying the effects of variations in tissue oxygenation and in parameters controlling the rate of cellular respiration on glycolysis, lactate production, and pyruvate oxidation. The whole body is described as a bioenergetic system consisting of metabolically distinct tissue/organ subsystems that exchange materials with the blood. In order to study the dynamic response of each subsystem to stimuli, we solve the ordinary differential equations describing the temporal evolution of metabolite levels, given the initial concentrations. The solver used in the present study is the packaged code LSODE, as implemented in the NASA Lewis kinetics and sensitivity analysis code, LSENS. A major advantage of LSENS is the efficient procedures supporting systematic sensitivity analysis, which provides the basic methods for studying parameter sensitivities (i.e., changes in model behavior due to parameter variation). Sensitivity analysis establishes relationships between model predictions and problem parameters (i.e., initial concentrations, rate coefficients, etc). It helps determine the effects of uncertainties or changes in these input parameters on the predictions, which ultimately are compared with experimental observations in order to validate the model. Sensitivity analysis can identify parameters that must be determined accurately because of their large effect on the model predictions and parameters that need not be known with great precision because they have little or no effect on the solution. This capability may prove to be important in optimizing the design of experiments, thereby reducing the use of animals. This approach can be applied to study the metabolic effects of reduced oxygen delivery to cardiac muscle due to local myocardial ischemia and the effects of acute hypoxia on brain metabolism. Other important applications of sensitivity analysis include identification of quantitatively relevant pathways and biochemical species within an overall mechanism, when examining the effects of a genetic anomaly or pathological state on energetic system components and whole system behavior.

  13. Manual versus Automated Rodent Behavioral Assessment: Comparing Efficacy and Ease of Bederson and Garcia Neurological Deficit Scores to an Open Field Video-Tracking System.

    PubMed

    Desland, Fiona A; Afzal, Aqeela; Warraich, Zuha; Mocco, J

    2014-01-01

    Animal models of stroke have been crucial in advancing our understanding of the pathophysiology of cerebral ischemia. Currently, the standards for determining neurological deficit in rodents are the Bederson and Garcia scales, manual assessments scoring animals based on parameters ranked on a narrow scale of severity. Automated open field analysis of a live-video tracking system that analyzes animal behavior may provide a more sensitive test. Results obtained from the manual Bederson and Garcia scales did not show significant differences between pre- and post-stroke animals in a small cohort. When using the same cohort, however, post-stroke data obtained from automated open field analysis showed significant differences in several parameters. Furthermore, large cohort analysis also demonstrated increased sensitivity with automated open field analysis versus the Bederson and Garcia scales. These early data indicate use of automated open field analysis software may provide a more sensitive assessment when compared to traditional Bederson and Garcia scales.

  14. Comparative study of CEA and CA19-9 in esophageal, gastric and colon cancers individually and in combination (ROC curve analysis).

    PubMed

    Bagaria, Bhawna; Sood, Sadhna; Sharma, Rameshwaram; Lalwani, Soniya

    2013-09-01

    To determine the clinical serum levels of carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA19-9), individually and in combination, for the diagnosis of 50 healthy subjects and 150 cases of esophageal, gastric, and colon cancers. The sensitivities of the two markers were compared individually and in combination, with specificity set at 100%. Receiver operating characteristic (ROC) curves were plotted. Serum CEA levels were significantly higher in cancer patients than in the control group. The sensitivity of CEA was determined: in esophageal cancer, sensitivity=28%, negative predictive value (NPV)=61.72%, and AUC=0.742 
(SE=0.05), with a significance level of P<0.0001; in gastric cancer, sensitivity=30%, NPV=58.82%, and AUC=0.734 (SE=0.05), with a significance level of P<0.0001; in colon cancer, sensitivity=74%, NPV=79.36%, and AUC=0.856 
(SE=0.04), with a significance level of P<0.0001. The sensitivity of CA19-9 was also evaluated: in esophageal cancer, sensitivity=18%, NPV=54.94%, and AUC=0.573 (SE =0.05), with a significance level of P=0.2054. In gastric cancer, sensitivity=42%, NPV=63.29%, and AUC=0.679 (SE =0.05), with a significance level of P<0.0011. In colon cancer, sensitivity=26%, NPV=57.47%, and AUC=0.580 (SE =0.05), with a significance level of P=0.1670. The following were the sensitivities of CEA/CA19-9 combined: in esophageal cancer, sensitivity=42%, NPV=63.29%, SE=0.078 (95% CI: 0.0159-0.322); gastric cancer, sensitivity=58%, NPV=70.42%, SE=0.072 (95% CI: -0.0866-0.198); and colon cancer, sensitivity=72%, NPV=78.12%, SE=0.070 (95% CI: 0.137-0.415). CEA exhibited the highest sensitivity for colon cancer, and CA19-9 exhibited the highest sensitivity for gastric cancer. Combined analysis indicated an increase in diagnostic sensitivity in esophageal and gastric cancer compared with that in colon cancer.

  15. Analysis of sensitivity of simulated recharge to selected parameters for seven watersheds modeled using the precipitation-runoff modeling system

    USGS Publications Warehouse

    Ely, D. Matthew

    2006-01-01

    Recharge is a vital component of the ground-water budget and methods for estimating it range from extremely complex to relatively simple. The most commonly used techniques, however, are limited by the scale of application. One method that can be used to estimate ground-water recharge includes process-based models that compute distributed water budgets on a watershed scale. These models should be evaluated to determine which model parameters are the dominant controls in determining ground-water recharge. Seven existing watershed models from different humid regions of the United States were chosen to analyze the sensitivity of simulated recharge to model parameters. Parameter sensitivities were determined using a nonlinear regression computer program to generate a suite of diagnostic statistics. The statistics identify model parameters that have the greatest effect on simulated ground-water recharge and that compare and contrast the hydrologic system responses to those parameters. Simulated recharge in the Lost River and Big Creek watersheds in Washington State was sensitive to small changes in air temperature. The Hamden watershed model in west-central Minnesota was developed to investigate the relations that wetlands and other landscape features have with runoff processes. Excess soil moisture in the Hamden watershed simulation was preferentially routed to wetlands, instead of to the ground-water system, resulting in little sensitivity of any parameters to recharge. Simulated recharge in the North Fork Pheasant Branch watershed, Wisconsin, demonstrated the greatest sensitivity to parameters related to evapotranspiration. Three watersheds were simulated as part of the Model Parameter Estimation Experiment (MOPEX). Parameter sensitivities for the MOPEX watersheds, Amite River, Louisiana and Mississippi, English River, Iowa, and South Branch Potomac River, West Virginia, were similar and most sensitive to small changes in air temperature and a user-defined flow routing parameter. Although the primary objective of this study was to identify, by geographic region, the importance of the parameter value to the simulation of ground-water recharge, the secondary objectives proved valuable for future modeling efforts. The value of a rigorous sensitivity analysis can (1) make the calibration process more efficient, (2) guide additional data collection, (3) identify model limitations, and (4) explain simulated results.

  16. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Mai, J.; Tolson, B.

    2017-12-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method's independency of the convergence testing method, we applied it to two widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991) and the variance-based Sobol' method (Solbol' 1993). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an efficient way. The appealing feature of this new technique is the necessity of no further model evaluation and therefore enables checking of already processed sensitivity results. This is one step towards reliable and transferable, published sensitivity results.

  17. Determination of T-2 and HT-2 toxins from maize by direct analysis in real time mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Direct analysis in real time (DART) ionization coupled to mass spectrometry (MS) was used for the rapid quantitative analysis of T-2 toxin, and the related HT-2 toxin, extracted from corn. Sample preparation procedures and instrument parameters were optimized to obtain sensitive and accurate determi...

  18. Purification of Derivatized Oligosaccharides by Solid Phase Extraction for Glycomic Analysis

    PubMed Central

    Zhang, Qiwei; Li, Henghui; Feng, Xiaojun; Liu, Bi-Feng; Liu, Xin

    2014-01-01

    Profiling of glycans released from proteins is very complex and important. To enhance the detection sensitivity, chemical derivatization is required for the analysis of carbohydrates. Due to the interference of excess reagents, a simple and reliable purification method is usually necessary for the derivatized oligosaccharides. Various SPE based methods have been applied for the clean-up process. To demonstrate the differences among these methods, seven types of self-packed SPE cartridges were systematically compared in this study. The optimized conditions were determined for each type of cartridge and it was found that microcrystalline cellulose was the most appropriate SPE material for the purification of derivatized oligosaccharide. Normal phase HPLC analysis of the derivatized maltoheptaose was realized with a detection limit of 0.12 pmol (S N−1 = 3) and a recovery over 70%. With the optimized SPE method, relative quantification analysis of N-glycans from model glycoproteins were carried out accurately and over 40 N-glycans from human serum samples were determined regardless of the isomers. Due to the high stability and sensitivity, microcrystalline cellulose cartridge showed potential applications in glycomics analysis. PMID:24705408

  19. Identification of biomarkers in human head and neck tumor cell lines that predict for in vitro sensitivity to gefitinib.

    PubMed

    Hickinson, D Mark; Marshall, Gayle B; Beran, Garry J; Varella-Garcia, Marileila; Mills, Elizabeth A; South, Marie C; Cassidy, Andrew M; Acheson, Kerry L; McWalter, Gael; McCormack, Rose M; Bunn, Paul A; French, Tim; Graham, Alex; Holloway, Brian R; Hirsch, Fred R; Speake, Georgina

    2009-06-01

    Potential biomarkers were identified for in vitro sensitivity to the epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor gefitinib in head and neck cancer. Gefitinib sensitivity was determined in cell lines, followed by transcript profiling coupled with a novel pathway analysis approach. Eleven cell lines were highly sensitive to gefitinib (inhibitor concentration required to give 50% growth inhibition [GI(50)] < 1 microM), three had intermediate sensitivity (GI(50) 1-7 microM), and six were resistant (GI(50) > 7 microM); an exploratory principal component analysis revealed a separation between the genomic profiles of sensitive and resistant cell lines. Subsequently, a hypothesis-driven analysis of Affymetrix data (Affymetrix, Inc., Santa Clara, CA, USA) revealed higher mRNA levels for E-cadherin (CDH1); transforming growth factor, alpha (TGF-alpha); amphiregulin (AREG); FLJ22662; EGFR; p21-activated kinase 6 (PAK6); glutathione S-transferase Pi (GSTP1); and ATP-binding cassette, subfamily C, member 5 (ABCC5) in sensitive versus resistant cell lines. A hypothesis-free analysis identified 46 gene transcripts that were strongly differentiated, seven of which had a known association with EGFR and head and neck cancer (human EGF receptor 3 [HER3], TGF-alpha, CDH1, EGFR, keratin 16 [KRT16], fibroblast growth factor 2 [FGF2], and cortactin [CTTN]). Polymerase chain reaction (PCR) and enzyme-linked immunoabsorbant assay analysis confirmed Affymetrix data, and EGFR gene mutation, amplification, and genomic gain correlated strongly with gefitinib sensitivity. We identified biomarkers that predict for in vitro responsiveness to gefitinib, seven of which have known association with EGFR and head and neck cancer. These in vitro predictive biomarkers may have potential utility in the clinic and warrant further investigation.

  20. Quantitative method to determine the regional drinking water odorant regulation goals based on odor sensitivity distribution: illustrated using 2-MIB.

    PubMed

    Yu, Jianwei; An, Wei; Cao, Nan; Yang, Min; Gu, Junong; Zhang, Dong; Lu, Ning

    2014-07-01

    Taste and odor (T/O) in drinking water often cause consumer complaints and are thus regulated in many countries. However, people in different regions may exhibit different sensitivities toward T/O. This study proposed a method to determine the regional drinking water odorant regulation goals (ORGs) based on the odor sensitivity distribution of the local population. The distribution of odor sensitivity to 2-methylisoborneol (2-MIB) by the local population in Beijing, China was revealed by using a normal distribution function/model to describe the odor complaint response to a 2-MIB episode in 2005, and a 2-MIB concentration of 12.9 ng/L and FPA (flavor profile analysis) intensity of 2.5 was found to be the critical point to cause odor complaints. Thus the Beijing ORG for 2-MIB was determined to be 12.9 ng/L. Based on the assumption that the local FPA panel can represent the local population in terms of sensitivity to odor, and that the critical FPA intensity causing odor complaints was 2.5, this study tried to determine the ORGs for seven other cities of China by performing FPA tests using an FPA panel from the corresponding city. ORG values between 12.9 and 31.6 ng/L were determined, showing that a unified ORG may not be suitable for drinking water odor regulations. This study presents a novel approach for setting drinking water odor regulations. Copyright © 2014. Published by Elsevier B.V.

  1. Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography.

    PubMed

    Park, B Hyle; Pierce, Mark C; Cense, Barry; de Boer, Johannes F

    2005-10-01

    We present a generalized analysis of fiber-based polarization-sensitive optical coherence tomography with an emphasis on determination of sample optic axis orientation. The polarization properties of a fiber-based system can cause an overall rotation in a Poincaré sphere representation such that the plane of possible measured sample optic axes for linear birefringence and diattenuation no longer lies in the QU-plane. The optic axis orientation can be recovered as an angle on this rotated plane, subject to an offset and overall indeterminacy in sign such that only the magnitude, but not the direction, of a change in orientation can be determined. We discuss the accuracy of optic axis determination due to a fundamental limit on the accuracy with which a polarization state can be determined as a function of signal-to-noise ratio.

  2. Sensitive Determination of Onco-metabolites of D- and L-2-hydroxyglutarate Enantiomers by Chiral Derivatization Combined with Liquid Chromatography/Mass Spectrometry Analysis

    PubMed Central

    Cheng, Qing-Yun; Xiong, Jun; Huang, Wei; Ma, Qin; Ci, Weimin; Feng, Yu-Qi; Yuan, Bi-Feng

    2015-01-01

    2-hydroxyglutarate (2HG) is a potent competitor of α-ketoglutarate (α-KG) and can inhibit multiple α-KG dependent dioxygenases that function on the epigenetic modifications. The accumulation of 2HG contributes to elevated risk of malignant tumors. 2HG carries an asymmetric carbon atom in its carbon backbone and differentiation between D-2-hydroxyglutarate (D-2HG) and L-2-hydroxyglutarate (L-2HG) is crucially important for accurate diagnosis of 2HG related diseases. Here we developed a strategy by chiral derivatization combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis for highly sensitive determination of D-2HG and L-2HG enantiomers. N-(p-toluenesulfonyl)-L-phenylalanyl chloride (TSPC) was used to derivatize 2HG. The formed diastereomers by TSPC labeling can efficiently improve the chromatographic separation of D-2HG and L-2HG. And derivatization by TSPC could also markedly increase the detection sensitivities by 291 and 346 folds for D-2HG and L-2HG, respectively. Using the developed method, we measured the contents of D-2HG and L-2HG in clear cell renal cell carcinoma (ccRCC) tissues. We observed 12.9 and 29.8 folds increase of D-2HG and L-2HG, respectively, in human ccRCC tissues compared to adjacent normal tissues. The developed chiral derivatization combined with LC-ESI-MS/MS analysis offers sensitive determination of D-2HG and L-2HG enantiomers, which benefits the precise diagnosis of 2HG related metabolic diseases. PMID:26458332

  3. Electrochemical Determination of Chlorpyrifos on a Nano-TiO₂Cellulose Acetate Composite Modified Glassy Carbon Electrode.

    PubMed

    Kumaravel, Ammasai; Chandrasekaran, Maruthai

    2015-07-15

    A rapid and simple method of determination of chlorpyrifos is important in environmental monitoring and quality control. Electrochemical methods for the determination of pesticides are fast, sensitive, reproducible, and cost-effective. The key factor in electrochemical methods is the choice of suitable electrode materials. The electrode materials should have good stability, reproducibility, more sensitivity, and easy method of preparation. Mercury-based electrodes have been widely used for the determination of chlorpyrifos. From an environmental point of view mercury cannot be used. In this study a biocompatible nano-TiO2/cellulose acetate modified glassy carbon electrode was prepared by a simple method and used for the electrochemical sensing of chlorpyrifos in aqueous methanolic solution. Electroanalytical techniques such as cyclic voltammetry, differential pulse voltammetry, and amperometry were used in this work. This electrode showed very good stability, reproducibility, and sensitivity. A well-defined peak was obtained for the reduction of chlorpyrifos in cyclic voltammetry and differential pulse voltammetry. A smooth noise-free current response was obtained in amperometric analysis. The peak current obtained was proportional to the concentration of chlorpyrifos and was used to determine the unknown concentration of chlorpyrifos in the samples. Analytical parameters such as LOD, LOQ, and linear range were estimated. Analysis of real samples was also carried out. The results were validated through HPLC. This composite electrode can be used as an alternative to mercury electrodes reported in the literature.

  4. Laser-Excited Atomic Fluorescence and Ionization in a Graphite Furnace for the Determination of Metals and Nonmetals

    NASA Astrophysics Data System (ADS)

    Butcher, David James

    1990-01-01

    Here is reported novel instrumentation for atomic spectrometry that combined the use of a pulsed laser system as the light source and an electrothermal atomizer as the atom cell. The main goal of the research was to develop instrumentation that was more sensitive for elemental analysis than commercially available instruments and could be used to determine elements in real sample matrices. Laser excited atomic fluorescence spectrometry (LEAFS) in an electrothermal atomizer (ETA) was compared to ETA atomic absorption spectrometry (AAS) for the determination of thallium, manganese, and lead in food and agricultural standard reference materials (SRMs). Compared to ETA AAS, ETA LEAFS has a longer linear dynamic range (LDR) (5-7 orders of magnitude compared to 2-3 orders of magnitude) and higher sensitivity (10 ^{-16} to 10^{ -14} g as compared to 10^{ -13} to 10^{-11} g). Consequently, ETA LEAFS allows elemental analysis to be done over a wider range of concentrations with less dilution steps. Thallium was accurately determined in biological samples by ETA LEAFS at amounts five to one hundred times below the ETA AAS detection limit. ETA AAS and ETA LEAFS were compared for the determination of lead and manganese, and in general, the accuracies and precisions of ETA AAS were the same, with typical precisions between 3% and 6%. Fluorine was determined using laser excited molecular fluorescence spectrometry (LEMOFS) in an ETA. Molecular fluorescence from magnesium fluoride was collected, and the detection limit of 0.3 pg fluorine was two to six orders of magnitude more sensitive than other methods commonly used for the determination of fluorine. Significant interferences from ions were observed, but the sensitivity was high enough that fluorine could be determined in freeze dried urine SRMs by diluting the samples by a factor of one hundred to remove the interferences. Laser enhanced ionization (LEI) in an ETA was used for the determination of metals. For thallium, indium, and lithium, detection limits between 0.7 and 2 pg were obtained, with an LDR of 3.5 orders of magnitude. Sodium was shown to severely depress the indium LEI signal in an ETA.

  5. Design, calibration and application of broad-range optical nanosensors for determining intracellular pH.

    PubMed

    Søndergaard, Rikke V; Henriksen, Jonas R; Andresen, Thomas L

    2014-12-01

    Particle-based nanosensors offer a tool for determining the pH in the endosomal-lysosomal system of living cells. Measurements providing absolute values of pH have so far been restricted by the limited sensitivity range of nanosensors, calibration challenges and the complexity of image analysis. This protocol describes the design and application of a polyacrylamide-based nanosensor (∼60 nm) that covalently incorporates two pH-sensitive fluorophores, fluorescein (FS) and Oregon Green (OG), to broaden the sensitivity range of the sensor (pH 3.1-7.0), and uses the pH-insensitive fluorophore rhodamine as a reference fluorophore. The nanosensors are spontaneously taken up via endocytosis and directed to the lysosomes where dynamic changes in pH can be measured with live-cell confocal microscopy. The most important focus areas of the protocol are the choice of pH-sensitive fluorophores, the design of calibration buffers, the determination of the effective range and especially the description of how to critically evaluate results. The entire procedure typically takes 2-3 weeks.

  6. Global Sensitivity of Simulated Water Balance Indicators Under Future Climate Change in the Colorado Basin

    NASA Astrophysics Data System (ADS)

    Bennett, Katrina E.; Urrego Blanco, Jorge R.; Jonko, Alexandra; Bohn, Theodore J.; Atchley, Adam L.; Urban, Nathan M.; Middleton, Richard S.

    2018-01-01

    The Colorado River Basin is a fundamentally important river for society, ecology, and energy in the United States. Streamflow estimates are often provided using modeling tools which rely on uncertain parameters; sensitivity analysis can help determine which parameters impact model results. Despite the fact that simulated flows respond to changing climate and vegetation in the basin, parameter sensitivity of the simulations under climate change has rarely been considered. In this study, we conduct a global sensitivity analysis to relate changes in runoff, evapotranspiration, snow water equivalent, and soil moisture to model parameters in the Variable Infiltration Capacity (VIC) hydrologic model. We combine global sensitivity analysis with a space-filling Latin Hypercube Sampling of the model parameter space and statistical emulation of the VIC model to examine sensitivities to uncertainties in 46 model parameters following a variance-based approach. We find that snow-dominated regions are much more sensitive to uncertainties in VIC parameters. Although baseflow and runoff changes respond to parameters used in previous sensitivity studies, we discover new key parameter sensitivities. For instance, changes in runoff and evapotranspiration are sensitive to albedo, while changes in snow water equivalent are sensitive to canopy fraction and Leaf Area Index (LAI) in the VIC model. It is critical for improved modeling to narrow uncertainty in these parameters through improved observations and field studies. This is important because LAI and albedo are anticipated to change under future climate and narrowing uncertainty is paramount to advance our application of models such as VIC for water resource management.

  7. Diagnostic value of immunoglobulin κ light chain gene rearrangement analysis in B-cell lymphomas.

    PubMed

    Kokovic, Ira; Jezersek Novakovic, Barbara; Novakovic, Srdjan

    2015-03-01

    Analysis of the immunoglobulin κ light chain (IGK) gene is an alternative method for B-cell clonality assessment in the diagnosis of mature B-cell proliferations in which the detection of clonal immunoglobulin heavy chain (IGH) gene rearrangements fails. The aim of the present study was to evaluate the added value of standardized BIOMED-2 assay for the detection of clonal IGK gene rearrangements in the diagnostic setting of suspected B-cell lymphomas. With this purpose, 92 specimens from 80 patients with the final diagnosis of mature B-cell lymphoma (37 specimens), mature T-cell lymphoma (26 specimens) and reactive lymphoid proliferation (29 specimens) were analyzed for B-cell clonality. B-cell clonality analysis was performed using the BIOMED-2 IGH and IGK gene clonality assays. The determined sensitivity of the IGK assay was 67.6%, while the determined sensitivity of the IGH assay was 75.7%. The sensitivity of combined IGH+IGK assay was 81.1%. The determined specificity of the IGK assay was 96.2% in the group of T-cell lymphomas and 96.6% in the group of reactive lesions. The determined specificity of the IGH assay was 84.6% in the group of lymphomas and 86.2% in the group of reactive lesions. The comparison of GeneScan (GS) and heteroduplex pretreatment-polyacrylamide gel electrophoresis (HD-PAGE) methods for the analysis of IGK gene rearrangements showed a higher efficacy of GS analysis in a series of 27 B-cell lymphomas analyzed by both methods. In the present study, we demonstrated that by applying the combined IGH+IGK clonality assay the overall detection rate of B-cell clonality was increased by 5.4%. Thus, we confirmed the added value of the standardized BIOMED-2 IGK assay for assessment of B-cell clonality in suspected B-cell lymphomas with inconclusive clinical and cyto/histological diagnosis.

  8. Prevalence of and risk factors for latex sensitization in patients with spina bifida.

    PubMed

    Bernardini, R; Novembre, E; Lombardi, E; Mezzetti, P; Cianferoni, A; Danti, A D; Mercurella, A; Vierucci, A

    1998-11-01

    We determined the prevalence of and risk factors for latex sensitization in patients with spina bifida. A total of 59 consecutive subjects 2 to 40 years old with spina bifida answered a questionnaire, and underwent a latex skin prick test and determination of serum IgE specific for latex by RAST CAP radioimmunoassay. We also noted the relationships of total serum IgE skin prick tests to common air and food allergens. In addition, skin prick plus prick tests were also done with fresh foods, including kiwi, pear, orange, almond, pineapple, apple, tomato and banana. Latex sensitization was present in 15 patients (25%) according to the presence of IgE specific to latex, as detected by a skin prick test in 9 and/or RAST CAP in 13. Five latex sensitized patients (33.3%) had clinical manifestations, such as urticaria, conjuctivitis, angioedema, rhinitis and bronchial asthma, while using a latex glove and inflating a latex balloon. Atopy was present in 21 patients (35.6%). In 14 patients (23%) 1 or more skin tests were positive for fresh foods using a prick plus prick technique. Tomato, kiwi, and pear were the most common skin test positive foods. Univariate analysis revealed that a history of 5 or more operations, atopy and positive prick plus prick tests results for pear and kiwi were significantly associated with latex sensitization. Multivariate analysis demonstrated that only atopy and a history of 5 or more operations were significantly and independently associated with latex sensitization. A fourth of the patients with spina bifida were sensitized to latex. Atopy and an elevated number of operations were significant and independent predictors of latex sensitization in these cases.

  9. Determination of trace amino acids in human serum by a selective and sensitive pre-column derivatization method using HPLC-FLD-MS/MS and derivatization optimization by response surface methodology.

    PubMed

    Li, Guoliang; Cui, Yanyan; You, Jinmao; Zhao, Xianen; Sun, Zhiwei; Xia, Lian; Suo, Yourui; Wang, Xiao

    2011-04-01

    Analysis of trace amino acids (AA) in physiological fluids has received more attention, because the analysis of these compounds could provide fundamental and important information for medical, biological, and clinical researches. More accurate method for the determination of those compounds is highly desirable and valuable. In the present study, we developed a selective and sensitive method for trace AA determination in biological samples using 2-[2-(7H-dibenzo [a,g]carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC) as labeling reagent by HPLC-FLD-MS/MS. Response surface methodology (RSM) was first employed to optimize the derivatization reaction between DBCEC and AA. Compared with traditional single-factor design, RSM was capable of lessening laborious, time and reagents consumption. The complete derivatization can be achieved within 6.3 min at room temperature. In conjunction with a gradient elution, a baseline resolution of 20 AA containing acidic, neutral, and basic AA was achieved on a reversed-phase Hypersil BDS C(18) column. This method showed excellent reproducibility and correlation coefficient, and offered the exciting detection limits of 0.19-1.17 fmol/μL. The developed method was successfully applied to determinate AA in human serum. The sensitive and prognostic index of serum AA for liver diseases has also been discussed.

  10. Cost-Effectiveness Analysis of Preoperative Versus Postoperative Radiation Therapy in Extremity Soft Tissue Sarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, Xuanlu M.; Louie, Alexander V.; Ashman, Jonathan

    Purpose: Surgery combined with radiation therapy (RT) is the cornerstone of multidisciplinary management of extremity soft tissue sarcoma (STS). Although RT can be given in either the preoperative or the postoperative setting with similar local recurrence and survival outcomes, the side effect profiles, costs, and long-term functional outcomes are different. The aim of this study was to use decision analysis to determine optimal sequencing of RT with surgery in patients with extremity STS. Methods and Materials: A cost-effectiveness analysis was conducted using a state transition Markov model, with quality-adjusted life years (QALYs) as the primary outcome. A time horizon ofmore » 5 years, a cycle length of 3 months, and a willingness-to-pay threshold of $50,000/QALY was used. One-way deterministic sensitivity analyses were performed to determine the thresholds at which each strategy would be preferred. The robustness of the model was assessed by probabilistic sensitivity analysis. Results: Preoperative RT is a more cost-effective strategy ($26,633/3.00 QALYs) than postoperative RT ($28,028/2.86 QALYs) in our base case scenario. Preoperative RT is the superior strategy with either 3-dimensional conformal RT or intensity-modulated RT. One-way sensitivity analyses identified the relative risk of chronic adverse events as having the greatest influence on the preferred timing of RT. The likelihood of preoperative RT being the preferred strategy was 82% on probabilistic sensitivity analysis. Conclusions: Preoperative RT is more cost effective than postoperative RT in the management of resectable extremity STS, primarily because of the higher incidence of chronic adverse events with RT in the postoperative setting.« less

  11. Analysis techniques for multivariate root loci. [a tool in linear control systems

    NASA Technical Reports Server (NTRS)

    Thompson, P. M.; Stein, G.; Laub, A. J.

    1980-01-01

    Analysis and techniques are developed for the multivariable root locus and the multivariable optimal root locus. The generalized eigenvalue problem is used to compute angles and sensitivities for both types of loci, and an algorithm is presented that determines the asymptotic properties of the optimal root locus.

  12. Chemical Analysis through CL-Detection Assisted by Periodate Oxidation

    PubMed Central

    Evmiridis, Nicholaos P.; Vlessidis, Athanasios G.; Thanasoulias, Nicholas C.

    2007-01-01

    The progress of the research work of the author and his colleagues on the field of CL-emission generated by pyrogallol oxidation and further application for the direct determination of periodate and indirect or direct determination of other compounds through flow-injection manifold/CL-detection set up is described. The instrumentation used for these studies was a simple flow-injection manifold that provides good reproducibility, coupled to a red sensitive photomultiplier that gives sensitive CL-detection. In addition, recent reports on studies and analytical methods based on CL-emission generated by periodate oxidation by other authors are included. PMID:17611611

  13. [Determination of triterpenoic acids in fruits of Ziziphus jujuba using HPLC-MS with polymeric ODS column].

    PubMed

    Zhang, Yong; Zhou, An; Xie, Xiao-Mei

    2013-03-01

    A simple and sensitive method has been developed to simultaneously determine betunilic acid, oleanolic acid and ursolic acid in the fruits of Ziziphus jujuba from different regions by HPLC-MS. This HPLC assay was performed on PAH polymeric C18 bonded stationary phase column with mobile phase contained acetonitrile-water (90: 10) and with negative ESI detection mode. The developed approach was characterized by short time consumption for chromatographic separation, high sensitivity and good reliability so as to meet the requirements for rapid analysis of large-batch fruits of Z. jujuba from different habitats.

  14. Space shuttle orbiter digital data processing system timing sensitivity analysis OFT ascent phase

    NASA Technical Reports Server (NTRS)

    Lagas, J. J.; Peterka, J. J.; Becker, D. A.

    1977-01-01

    Dynamic loads were investigated to provide simulation and analysis of the space shuttle orbiter digital data processing system (DDPS). Segments of the ascent test (OFT) configuration were modeled utilizing the information management system interpretive model (IMSIM) in a computerized simulation modeling of the OFT hardware and software workload. System requirements for simulation of the OFT configuration were defined, and sensitivity analyses determined areas of potential data flow problems in DDPS operation. Based on the defined system requirements and these sensitivity analyses, a test design was developed for adapting, parameterizing, and executing IMSIM, using varying load and stress conditions for model execution. Analyses of the computer simulation runs are documented, including results, conclusions, and recommendations for DDPS improvements.

  15. Automatic Target Recognition Classification System Evaluation Methodology

    DTIC Science & Technology

    2002-09-01

    Testing Set of Two-Class XOR Data (250 Samples)......................................... 2-59 2.27 Decision Analysis Process Flow Chart...ROC curve meta - analysis , which is the estimation of the true ROC curve of a given diagnostic system through ROC analysis across many studies or...technique can be very effective in sensitivity analysis ; trying to determine which data points have the most effect on the solution, and in

  16. System and method for high precision isotope ratio destructive analysis

    DOEpatents

    Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

    2013-07-02

    A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

  17. Simplifiying global biogeochemistry models to evaluate methane emissions

    NASA Astrophysics Data System (ADS)

    Gerber, S.; Alonso-Contes, C.

    2017-12-01

    Process-based models are important tools to quantify wetland methane emissions, particularly also under climate change scenarios, evaluating these models is often cumbersome as they are embedded in larger land-surface models where fluctuating water table and the carbon cycle (including new readily decomposable plant material) are predicted variables. Here, we build on these large scale models but instead of modeling water table and plant productivity we provide values as boundary conditions. In contrast, aerobic and anaerobic decomposition, as well as soil column transport of oxygen and methane are predicted by the model. Because of these simplifications, the model has the potential to be more readily adaptable to the analysis of field-scale data. Here we determine the sensitivity of the model to specific setups, parameter choices, and to boundary conditions in order to determine set-up needs and inform what critical auxiliary variables need to be measured in order to better predict field-scale methane emissions from wetland soils. To that end we performed a global sensitivity analysis that also considers non-linear interactions between processes. The global sensitivity analysis revealed, not surprisingly, that water table dynamics (both mean level and amplitude of fluctuations), and the rate of the carbon cycle (i.e. net primary productivity) are critical determinants of methane emissions. The depth-scale where most of the potential decomposition occurs also affects methane emissions. Different transport mechanisms are compensating each other to some degree: If plant conduits are constrained, methane emissions by diffusive flux and ebullition compensate to some degree, however annual emissions are higher when plants help to bypass methanotrophs in temporally unsaturated upper layers. Finally, while oxygen consumption by plant roots help creating anoxic conditions it has little effect on overall methane emission. Our initial sensitivity analysis helps guiding further model development and improvement. However, an important goal for our model is to use it in field settings as a tool to deconvolve the different processes that contribute to the net transfer of methane from soils to atmosphere.

  18. The effects of physical activity on impulsive choice: Influence of sensitivity to reinforcement amount and delay.

    PubMed

    Strickland, Justin C; Feinstein, Max A; Lacy, Ryan T; Smith, Mark A

    2016-05-01

    Impulsive choice is a diagnostic feature and/or complicating factor for several psychological disorders and may be examined in the laboratory using delay-discounting procedures. Recent investigators have proposed using quantitative measures of analysis to examine the behavioral processes contributing to impulsive choice. The purpose of this study was to examine the effects of physical activity (i.e., wheel running) on impulsive choice in a single-response, discrete-trial procedure using two quantitative methods of analysis. To this end, rats were assigned to physical activity or sedentary groups and trained to respond in a delay-discounting procedure. In this procedure, one lever always produced one food pellet immediately, whereas a second lever produced three food pellets after a 0, 10, 20, 40, or 80-s delay. Estimates of sensitivity to reinforcement amount and sensitivity to reinforcement delay were determined using (1) a simple linear analysis and (2) an analysis of logarithmically transformed response ratios. Both analyses revealed that physical activity decreased sensitivity to reinforcement amount and sensitivity to reinforcement delay. These findings indicate that (1) physical activity has significant but functionally opposing effects on the behavioral processes that contribute to impulsive choice and (2) both quantitative methods of analysis are appropriate for use in single-response, discrete-trial procedures. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. SENSITIVITY OF BLIND PULSAR SEARCHES WITH THE FERMI LARGE AREA TELESCOPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dormody, M.; Johnson, R. P.; Atwood, W. B.

    2011-12-01

    We quantitatively establish the sensitivity to the detection of young to middle-aged, isolated, gamma-ray pulsars through blind searches of Fermi Large Area Telescope (LAT) data using a Monte Carlo simulation. We detail a sensitivity study of the time-differencing blind search code used to discover gamma-ray pulsars in the first year of observations. We simulate 10,000 pulsars across a broad parameter space and distribute them across the sky. We replicate the analysis in the Fermi LAT First Source Catalog to localize the sources, and the blind search analysis to find the pulsars. We analyze the results and discuss the effect ofmore » positional error and spin frequency on gamma-ray pulsar detections. Finally, we construct a formula to determine the sensitivity of the blind search and present a sensitivity map assuming a standard set of pulsar parameters. The results of this study can be applied to population studies and are useful in characterizing unidentified LAT sources.« less

  20. Low sensitivity of implant sonication when screening for infection in revision surgery

    PubMed Central

    Van Diek, Floor M; Albers, Christiaan G M; Van Hooff, Miranda L; Meis, Jacques F; Goosen, Jon H M

    2017-01-01

    Background and purpose Prosthetic-joint infection (PJI) is the most serious complication of arthroplasty, and accurate identification of a potentially responsible microorganism is essential for successful antibiotic treatment. We therefore determined the diagnostic accuracy of sonication and compared it with tissue culture as a screening tool in detecting prosthetic joint infection in revision arthroplasty. Patients and methods 252 consecutive revision arthroplasty cases were enrolled. These cases were determined as being suspected or unsuspected of having infection according to standard criteria. Perioperatively, 6 periprosthetic interface tissue biopsies were obtained from each patient and the implants removed were sonicated. The sensitivity and specificity of periprosthetic tissue culture and sonication fluid cultures were determined. Results Preoperatively, 75 revision cases were classified as having PJI (33 early and 42 late) and 177 were unsuspected of having infection. Compared with tissue culture, the sensitivity of the sonication fluid analysis was low: 0.47 (95% CI: 0.35–0.59) for sonication as compared to 0.68 (95% CI: 0.56–0.78) for tissue culture. The specificity of the sonication fluid analysis was higher than that for tissue culture: 0.99 (95% CI: 0.96–1.0) as compared to 0.80 (95% CI: 0.74–0.86). Interpretation Sonication is a highly specific test for diagnosis of PJI. However, due to the low sensitivity, a negative sonication result does not rule out the presence of PJI. Thus, sonication is not of value for screening of microorganisms during revision surgery. PMID:28287012

  1. New reagent for extraction photomeric determination of anionic surface-active substances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chernova, R.K.; Yastrebova, N.I.; Pankratov, A.N.

    1995-02-01

    The new reagent 2,6-diphenyl-4-(4-dimethylamino)styrylpyryl chloride is suggested for extraction photometric determination of anionic surface-active substances (SAS). This reagent possesses high sensitivity and selectivity, and can be used for the determination of both individual SAS of any kind and the total amount of anionic SAS. The reagent was used in analysis of highly mineralized statal waters and for the determination of sulfated products in polyoxyethylated alkylphenols.

  2. Diagnostic utility of attenuation measurement (Hounsfield units) in computed tomography stonogram in predicting the radio-opacity of urinary calculi in plain abdominal radiographs.

    PubMed

    Chua, Michael E; Gatchalian, Glenn T; Corsino, Michael Vincent; Reyes, Buenaventura B

    2012-10-01

    (1) To determine the best cut-off level of Hounsfield units (HU) in the CT stonogram that would predict the appearance of a urinary calculi in plain KUB X-ray; (2) to estimate the sensitivity and specificity of the best cut-off HU; and (3) to determine whether stone size and location affect the in vivo predictability. A prospective cross-sectional study of patients aged 18-85 diagnosed with urolithiases on CT stonogram with concurrent plain KUB radiograph was conducted. Appearance of stones was recorded, and significant difference between radiolucent and radio-opaque CT attenuation level was determined using ANOVA. Receiver operating characteristics (ROC) curve determined the best HU cut-off value. Stone size and location were used for factor variability analysis. A total of 184 cases were included in this study, and the average urolithiasis size on CT stonogram was 0.84 cm (0.3-4.9 cm). On KUB X-ray, 34.2 % of the urolithiases were radiolucent and 65.8 % were radio-opaque. Mean value of CT Hounsfield unit for radiolucent stones was 358.25 (±156), and that for radio-opaque stones was 816.51 (±274). ROC curve determined the best cut-off value of HU at 498.5, with the sensitivity of 89.3 % and specificity of 87.3 %. For >4 mm stones, the sensitivity was 91.3 % and the specificity was 81.8 %. On the other hand, for =<4 mm stones, the sensitivity was 60 % and the specificity was 89.5 %. Based on the constructed ROC curve, a threshold value of 498.5 HU in CT stonogram was established as cut-off in determining whether a calculus is radio-opaque or radiolucent. The determined overall sensitivity and specificity of the set cut-off HU value are optimal. Stone size but not location affects the sensitivity and specificity.

  3. Fluorescence-labeled methylation-sensitive amplified fragment length polymorphism (FL-MS-AFLP) analysis for quantitative determination of DNA methylation and demethylation status.

    PubMed

    Kageyama, Shinji; Shinmura, Kazuya; Yamamoto, Hiroko; Goto, Masanori; Suzuki, Koichi; Tanioka, Fumihiko; Tsuneyoshi, Toshihiro; Sugimura, Haruhiko

    2008-04-01

    The PCR-based DNA fingerprinting method called the methylation-sensitive amplified fragment length polymorphism (MS-AFLP) analysis is used for genome-wide scanning of methylation status. In this study, we developed a method of fluorescence-labeled MS-AFLP (FL-MS-AFLP) analysis by applying a fluorescence-labeled primer and fluorescence-detecting electrophoresis apparatus to the existing method of MS-AFLP analysis. The FL-MS-AFLP analysis enables quantitative evaluation of more than 350 random CpG loci per run. It was shown to allow evaluation of the differences in methylation level of blood DNA of gastric cancer patients and evaluation of hypermethylation and hypomethylation in DNA from gastric cancer tissue in comparison with adjacent non-cancerous tissue.

  4. Comparison of ion chromatographic methods based on conductivity detection, post-column-reaction and on-line-coupling IC-ICP-MS for the determination of bromate.

    PubMed

    Schminke, G; Seubert, A

    2000-02-01

    An established method for the determination of the disinfection by-product bromate is ion chromatography (IC). This paper presents a comparison of three IC methods based on either conductivity detection (IC-CD), a post-column-reaction (IC-PCR-VIS) or the on-line-coupling with inductively coupled plasma mass spectrometry (IC-ICP-MS). Main characteristics of the methods such as method detection limits (MDL), time of analysis and sample pretreatment are compared and applicability for routine analysis is critically discussed. The most sensitive and rugged method is IC-ICP-MS, followed by IC-PCR-VIS. The photometric detection is subject to a minor interference in real world samples, presumably caused by carbonate. The lowest sensitivity is shown by the IC-CD method as slowest method compared, which, in addition, requires a sample pretreatment. The highest amount of information is delivered by IC-PCR-VIS, which allows the simultaneous determination of the seven standard anions and bromate.

  5. A sensitive liquid chromatography-mass spectrometry method for the simultaneous determination in plasma of pentacyclic triterpenes of Olea europaea L.

    PubMed

    Giménez, Estela; Juan, M Emília; Calvo-Melià, Sara; Planas, Joana M

    2017-08-15

    Table olives are especially rich in pentacyclic triterpenic compounds, which exert several biological activities. A crucial step in order to know if these compounds could contribute to the beneficial and healthy properties of this food is their measurement in blood. Therefore, the present study describes a simple and accurate liquid-liquid extraction followed by LC-QqQ-MS analysis for the simultaneous determination of the main pentacyclic triterpenes from Olea europaea L. in rat plasma. The method was validated by the analysis of blank plasma samples spiked with pure compounds, obtaining a linear correlation, adequate sensitivity with a limit of quantification ranging from 1nM for maslinic acid to 10nM for uvaol. Precision and accuracy were lower than 10% in all cases and recoveries were between 95 and 104%. The oral administration of olives to rats and its determination in plasma verified that the established methodology is appropriate for bioavailability studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Global sensitivity analysis of a filtration model for submerged anaerobic membrane bioreactors (AnMBR).

    PubMed

    Robles, A; Ruano, M V; Ribes, J; Seco, A; Ferrer, J

    2014-04-01

    The results of a global sensitivity analysis of a filtration model for submerged anaerobic MBRs (AnMBRs) are assessed in this paper. This study aimed to (1) identify the less- (or non-) influential factors of the model in order to facilitate model calibration and (2) validate the modelling approach (i.e. to determine the need for each of the proposed factors to be included in the model). The sensitivity analysis was conducted using a revised version of the Morris screening method. The dynamic simulations were conducted using long-term data obtained from an AnMBR plant fitted with industrial-scale hollow-fibre membranes. Of the 14 factors in the model, six were identified as influential, i.e. those calibrated using off-line protocols. A dynamic calibration (based on optimisation algorithms) of these influential factors was conducted. The resulting estimated model factors accurately predicted membrane performance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

    NASA Technical Reports Server (NTRS)

    Panda, Binayak

    2009-01-01

    Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

  8. Methods for Initial Characterization of Campylobacter jejuni Bacteriophages.

    PubMed

    Sørensen, Martine Camilla Holst; Gencay, Yilmaz Emre; Brøndsted, Lone

    2017-01-01

    Here we describe an initial characterization of Campylobacter jejuni bacteriophages by host range analysis, genome size determination by pulsed-field gel electrophoresis, and receptor-type identification by screening mutants for phage sensitivity.

  9. Hwyneeds : a sensitivity analysis

    DOT National Transportation Integrated Search

    2000-01-01

    County highway needs identified in Iowa's Quadrennial Needs Study are used to determine the amount of funding allocated to each Iowa county for secondary highway improvements. The Iowa Department of Transportation uses a computer algorithm called HWY...

  10. Precision of Sensitivity in the Design Optimization of Indeterminate Structures

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Pai, Shantaram S.; Hopkins, Dale A.

    2006-01-01

    Design sensitivity is central to most optimization methods. The analytical sensitivity expression for an indeterminate structural design optimization problem can be factored into a simple determinate term and a complicated indeterminate component. Sensitivity can be approximated by retaining only the determinate term and setting the indeterminate factor to zero. The optimum solution is reached with the approximate sensitivity. The central processing unit (CPU) time to solution is substantially reduced. The benefit that accrues from using the approximate sensitivity is quantified by solving a set of problems in a controlled environment. Each problem is solved twice: first using the closed-form sensitivity expression, then using the approximation. The problem solutions use the CometBoards testbed as the optimization tool with the integrated force method as the analyzer. The modification that may be required, to use the stiffener method as the analysis tool in optimization, is discussed. The design optimization problem of an indeterminate structure contains many dependent constraints because of the implicit relationship between stresses, as well as the relationship between the stresses and displacements. The design optimization process can become problematic because the implicit relationship reduces the rank of the sensitivity matrix. The proposed approximation restores the full rank and enhances the robustness of the design optimization method.

  11. Dynamic sensitivity analysis of biological systems

    PubMed Central

    Wu, Wu Hsiung; Wang, Feng Sheng; Chang, Maw Shang

    2008-01-01

    Background A mathematical model to understand, predict, control, or even design a real biological system is a central theme in systems biology. A dynamic biological system is always modeled as a nonlinear ordinary differential equation (ODE) system. How to simulate the dynamic behavior and dynamic parameter sensitivities of systems described by ODEs efficiently and accurately is a critical job. In many practical applications, e.g., the fed-batch fermentation systems, the system admissible input (corresponding to independent variables of the system) can be time-dependent. The main difficulty for investigating the dynamic log gains of these systems is the infinite dimension due to the time-dependent input. The classical dynamic sensitivity analysis does not take into account this case for the dynamic log gains. Results We present an algorithm with an adaptive step size control that can be used for computing the solution and dynamic sensitivities of an autonomous ODE system simultaneously. Although our algorithm is one of the decouple direct methods in computing dynamic sensitivities of an ODE system, the step size determined by model equations can be used on the computations of the time profile and dynamic sensitivities with moderate accuracy even when sensitivity equations are more stiff than model equations. To show this algorithm can perform the dynamic sensitivity analysis on very stiff ODE systems with moderate accuracy, it is implemented and applied to two sets of chemical reactions: pyrolysis of ethane and oxidation of formaldehyde. The accuracy of this algorithm is demonstrated by comparing the dynamic parameter sensitivities obtained from this new algorithm and from the direct method with Rosenbrock stiff integrator based on the indirect method. The same dynamic sensitivity analysis was performed on an ethanol fed-batch fermentation system with a time-varying feed rate to evaluate the applicability of the algorithm to realistic models with time-dependent admissible input. Conclusion By combining the accuracy we show with the efficiency of being a decouple direct method, our algorithm is an excellent method for computing dynamic parameter sensitivities in stiff problems. We extend the scope of classical dynamic sensitivity analysis to the investigation of dynamic log gains of models with time-dependent admissible input. PMID:19091016

  12. Prioritization of pesticides based on daily dietary exposure potential as determined from the SHEDS model.

    PubMed

    Melnyk, Lisa Jo; Wang, Zhaohui; Li, Zhilin; Xue, Jianping

    2016-10-01

    A major pathway for exposure to many pesticides is through diet. The objectives were to rank pesticides by comparing their calculated daily dietary exposure as determined by EPA's Stochastic Human Exposure and Dose Simulation (SHEDS) to single pesticides for different age groups to acceptable daily intakes (ADI), characterize pesticide trends in exposures over different time periods, and determine commodities contributing to pesticide exposures. SHEDS was applied, using Pesticide Data Program (PDP) (1991-2011) and pesticide usage data on crops from USDA combined with NHANES dietary consumption data, to generate exposure estimates by age group. ADI data collected from EPA, WHO, and other sources were used to rank pesticides based on relativeness of the dietary exposure potential to ADI by age groups. Sensitivity analysis provided trends in pesticide exposures. Within SHEDS, commodities contributing the majority of pesticides with greatest exposure potential were determined. The results indicated that the highest ranking pesticides were methamidophos and diazinon which exceeded 100% of the ADI. Sensitivity analysis indicated that exposure to methamidophos, diazinon, malathion, ethion and formetanate hydrochloride had a marked decrease from 1991-1999 to 2000-2011. Contributions analysis indicated that apples, mushroom, carrots, and lettuce contributed to diazinon exposure. Beans and pepper contributed to methamidophos exposure. Published by Elsevier Ltd.

  13. Examining the accuracy of the infinite order sudden approximation using sensitivity analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eno, L.; Rabitz, H.

    1981-08-15

    A method is developed for assessing the accuracy of scattering observables calculated within the framework of the infinite order sudden (IOS) approximation. In particular, we focus on the energy sudden assumption of the IOS method and our approach involves the determination of the sensitivity of the IOS scattering matrix S/sup IOS/ with respect to a parameter which reintroduces the internal energy operator h/sub 0/ into the IOS Hamiltonian. This procedure is an example of sensitivity analysis of missing model components (h/sub 0/ in this case) in the reference Hamiltonian. In contrast to simple first-order perturbation theory a finite result ismore » obtained for the effect of h/sub 0/ on S/sup IOS/. As an illustration, our method of analysis is applied to integral state-to-state cross sections for the scattering of an atom and rigid rotor. Results are generated within the He+H/sub 2/ system and a comparison is made between IOS and coupled states cross sections and the corresponding IOS sensitivities. It is found that the sensitivity coefficients are very useful indicators of the accuracy of the IOS results. Finally, further developments and applications are discussed.« less

  14. A Comparison of the Sensitivities of Dominant Plant Species to Experimental Drought

    NASA Astrophysics Data System (ADS)

    Felton, A. J.; Smith, M.; Griffin-Nolan, R.; Slette, I.

    2015-12-01

    Locally and globally, climate extremes are expected to become an increasingly important determinant of terrestrial ecosystem structure and functioning. In particular, extreme drought events are likely to have the most pronounced and negative impact on biodiversity (Tilman and El haddi 1992), carbon storage (Ciais et al. 2005) and cycling (Reichstein et al. 2013). As a consequence, an expressed need has been for a next generation of experiments designed to elucidate the causes and consequences of ecosystem sensitivity to drought (Smith 2011, Reichstein et al. 2013). A recent analysis of the 2012 U.S. Southwest drought revealed different sensitivities in primary production across five grassland ecosystems positioned along a precipitation gradient, with the most mesic (wet) grassland less sensitive than the most xeric (dry) grassland (Knapp et al. 2015). While this analysis suggests increasing sensitivity to drought with decreasing mean annual precipitation (MAP), an understanding of the relative roles of the abiotic (e.g., resource availability) and biotic (e.g., species identity) ecosystem components in driving this sensitivity trend is unclear. To address this uncertainty, we conducted a soil moisture manipulation study using the dominant grass species from the tallgrass prairie (892mm MAP), the shortgrass steppe (372mm MAP), and desert grassland (246mm MAP). The study imposed a "dry-down" to four target levels of volumetric soil water content at 25%, 20%, 15% and 10% to simulate different drought intensities. Each plant species experienced identical levels of water availability, with environmental conditions such as soil resource supply and temperature also held constant. Thus, this study allowed us to isolate each species sensitivity to water availability without confounding environmental differences. Measurements included growth rates of stem outputs and photosynthetically active leaves, maximum carbon assimilation, above and belowground net primary production. In total, the proposed application of this study is to contribute towards an understanding of the determinants of grassland ecosystem sensitivity to drought, with the underlying assumption that the responses of dominant plant species will largely determine ecosystem responses to contemporary and future climate change.

  15. Fast and sensitive trace analysis of malachite green using a surface-enhanced Raman microfluidic sensor.

    PubMed

    Lee, Sangyeop; Choi, Junghyun; Chen, Lingxin; Park, Byungchoon; Kyong, Jin Burm; Seong, Gi Hun; Choo, Jaebum; Lee, Yeonjung; Shin, Kyung-Hoon; Lee, Eun Kyu; Joo, Sang-Woo; Lee, Kyeong-Hee

    2007-05-08

    A rapid and highly sensitive trace analysis technique for determining malachite green (MG) in a polydimethylsiloxane (PDMS) microfluidic sensor was investigated using surface-enhanced Raman spectroscopy (SERS). A zigzag-shaped PDMS microfluidic channel was fabricated for efficient mixing between MG analytes and aggregated silver colloids. Under the optimal condition of flow velocity, MG molecules were effectively adsorbed onto silver nanoparticles while flowing along the upper and lower zigzag-shaped PDMS channel. A quantitative analysis of MG was performed based on the measured peak height at 1615 cm(-1) in its SERS spectrum. The limit of detection, using the SERS microfluidic sensor, was found to be below the 1-2 ppb level and this low detection limit is comparable to the result of the LC-Mass detection method. In the present study, we introduce a new conceptual detection technology, using a SERS microfluidic sensor, for the highly sensitive trace analysis of MG in water.

  16. Rapid quantification and sex determination of forensic evidence materials.

    PubMed

    Andréasson, Hanna; Allen, Marie

    2003-11-01

    DNA quantification of forensic evidence is very valuable for an optimal use of the available biological material. Moreover, sex determination is of great importance as additional information in criminal investigations as well as in identification of missing persons, no suspect cases, and ancient DNA studies. While routine forensic DNA analysis based on short tandem repeat markers includes a marker for sex determination, analysis of samples containing scarce amounts of DNA is often based on mitochondrial DNA, and sex determination is not performed. In order to allow quantification and simultaneous sex determination on minute amounts of DNA, an assay based on real-time PCR analysis of a marker within the human amelogenin gene has been developed. The sex determination is based on melting curve analysis, while an externally standardized kinetic analysis allows quantification of the nuclear DNA copy number in the sample. This real-time DNA quantification assay has proven to be highly sensitive, enabling quantification of single DNA copies. Although certain limitations were apparent, the system is a rapid, cost-effective, and flexible assay for analysis of forensic casework samples.

  17. Multi-immunosensors based on electrolite-insulator-semiconductor structures for determination of some herbicides

    NASA Astrophysics Data System (ADS)

    Starodub, Nickolaj F.; Starodub, Valentyna M.; Krivenchuk, Vladimir E.; Shapovalenko, Valentyna F.

    2002-02-01

    New type of the multi-immune sensor was elaborated. It is based on electrolyte-insulator-semiconductors structures and intended for determination of such herbicides as simazine, atrazine and 2,4-D. The specific antibodies were immobilized on nitrocellulose disks, which were placed in measuring cells. The analysis was fulfilled by sequential saturation of antibodies, left unbound after their exposure to native herbicide in investigated sample, with labelled herbicide. If horse radish peroxidase (HRP) was used as label the sensitivity of this multi-immune sensor was about 5 and 1.25 (mu) g/L for simazine and 2,4-D, respectively. At the changing of HRP by (beta) -glucose oxidase the sensitivity of analysis of these herbicides increased approximately in 5 times. The linear plots of the registered concentrations were in the range of 1,0-150,0 and 0,25-150,0 ng/mL for simazine and 2,4-D respectively. It was recommended to use the developed immune sensor for wide screening of herbicides in environment. The ways for increasing of its sensitivity were proposed.

  18. New Spectrofluorimetric Method with Enhanced Sensitivity for Determination of Paroxetine in Dosage Forms and Plasma

    PubMed Central

    Darwish, Ibrahim A.; Amer, Sawsan M.; Abdine, Heba H.; Al-Rayes, Lama I.

    2008-01-01

    New simple spectrofluorimetric method with enhanced sensitivity has been developed and validated for the determination of the antidepressant paroxetine (PXT) in its dosage forms and plasma. The method was based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium (pH 8) to form a highly fluorescent derivative that was measured at 545 nm after excitation at 490 nm. The factors affecting the reaction was carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was presented. Under the optimized conditions, linear relationship with good correlation coefficient (0.9993) was found between the fluorescence intensity and PXT concentration in the range of 80–800 ng ml−1. The limits of detection and quantitation for the method were 25 and 77 ng ml−1, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 3%. The proposed method was successfully applied to the determination of PXT in its pharmaceutical tablets with good accuracy; the recovery values were 100.2 ± 1.61%. The results obtained by the proposed method were comparable with those obtained by the official method. The proposed method is superior to the previously reported spectrofluorimetric method for determination of PXT in terms of its higher sensitivity and wider linear range. The high sensitivity of the method allowed its successful application to the analysis of PXT in spiked human plasma. The proposed method is practical and valuable for its routine application in quality control and clinical laboratories for analysis of PXT. PMID:19609398

  19. Comparison of the efficiency control of mycotoxins by some optical immune biosensors

    NASA Astrophysics Data System (ADS)

    Slyshyk, N. F.; Starodub, N. F.

    2013-11-01

    It was compared the efficiency of patulin control at the application of such optical biosensors which were based on the surface plasmon resonance (SPR) and nano-porous silicon (sNPS). In last case the intensity of the immune reaction was registered by measuring level of chemiluminescence (ChL) or photocurrent of nPS. The sensitivity of this mycotoxin determination by first type of immune biosensor was 0.05-10 mg/L Approximately the same sensitivity as well as the overall time analysis were demonstrated by the immune biosensor based on the nPS too. Nevertheless, the last type of biosensor was simpler in technical aspect and the cost of analysis was cheapest. That is why, it was recommend the nPS based immune biosensor for wide screening application and SPR one for some additional control or verification of preliminary obtained results. In this article a special attention was given to condition of sample preparation for analysis, in particular, micotoxin extraction from potao and some juices. Moreover, it was compared the efficiency of the above mentioned immune biosensors with such traditional approach of mycotoxin determination as the ELISA-method. In the result of investigation and discussion of obtained data it was concluded that both type of the immune biosensors are able to fulfill modern practice demand in respect sensitivity, rapidity, simplicity and cheapness of analysis.

  20. Use of a Smartphone as a Colorimetric Analyzer in Paper-based Devices for Sensitive and Selective Determination of Mercury in Water Samples.

    PubMed

    Jarujamrus, Purim; Meelapsom, Rattapol; Pencharee, Somkid; Obma, Apinya; Amatatongchai, Maliwan; Ditcharoen, Nadh; Chairam, Sanoe; Tamuang, Suparb

    2018-01-01

    A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (μPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on μPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L -1 , 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 μL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L -1 (r 2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h -1 , n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.

  1. Jet-A reaction mechanism study for combustion application

    NASA Technical Reports Server (NTRS)

    Lee, Chi-Ming; Kundu, Krishna; Acosta, Waldo

    1991-01-01

    Simplified chemical kinetic reaction mechanisms for the combustion of Jet A fuel was studied. Initially, 40 reacting species and 118 elementary chemical reactions were chosen based on a literature review. Through a sensitivity analysis with the use of LSENS General Kinetics and Sensitivity Analysis Code, 16 species and 21 elementary chemical reactions were determined from this study. This mechanism is first justified by comparison of calculated ignition delay time with the available shock tube data, then it is validated by comparison of calculated emissions from the plug flow reactor code with in-house flame tube data.

  2. Application of support vector machine method for the analysis of absorption spectra of exhaled air of patients with broncho-pulmonary diseases

    NASA Astrophysics Data System (ADS)

    Bukreeva, Ekaterina B.; Bulanova, Anna A.; Kistenev, Yury V.; Kuzmin, Dmitry A.; Tuzikov, Sergei A.; Yumov, Evgeny L.

    2014-11-01

    The results of the joint use of laser photoacoustic spectroscopy and chemometrics methods in gas analysis of exhaled air of patients with respiratory diseases (chronic obstructive pulmonary disease, pneumonia and lung cancer) are presented. The absorption spectra of exhaled breath of all volunteers were measured, the classification methods of the scans of the absorption spectra were applied, the sensitivity/specificity of the classification results were determined. It were obtained a result of nosological in pairs classification for all investigated volunteers, indices of sensitivity and specificity.

  3. Program Helps To Determine Chemical-Reaction Mechanisms

    NASA Technical Reports Server (NTRS)

    Bittker, D. A.; Radhakrishnan, K.

    1995-01-01

    General Chemical Kinetics and Sensitivity Analysis (LSENS) computer code developed for use in solving complex, homogeneous, gas-phase, chemical-kinetics problems. Provides for efficient and accurate chemical-kinetics computations and provides for sensitivity analysis for variety of problems, including problems involving honisothermal conditions. Incorporates mathematical models for static system, steady one-dimensional inviscid flow, reaction behind incident shock wave (with boundary-layer correction), and perfectly stirred reactor. Computations of equilibrium properties performed for following assigned states: enthalpy and pressure, temperature and pressure, internal energy and volume, and temperature and volume. Written in FORTRAN 77 with exception of NAMELIST extensions used for input.

  4. Seeded amplification of chronic wasting disease prions in nasal brushings and recto-anal mucosal associated lymphoid tissues from elk by real time quaking-induced conversion

    USGS Publications Warehouse

    Haley, Nicholas J.; Siepker, Chris; Hoon-Hanks , Laura L.; Mitchell, Gordon; Walter, W. David; Manca, Matteo; Monello, Ryan J.; Powers, Jenny G.; Wild, Margaret A.; Hoover, Edward A.; Caughey, Byron; Richt, Jürgen a.; Fenwick, B.W.

    2016-01-01

    Chronic wasting disease (CWD), a transmissible spongiform encephalopathy of cervids, was first documented nearly 50 years ago in Colorado and Wyoming and has since been detected across North America and the Republic of Korea. The expansion of this disease makes the development of sensitive diagnostic assays and antemortem sampling techniques crucial for the mitigation of its spread; this is especially true in cases of relocation/reintroduction or prevalence studies of large or protected herds, where depopulation may be contraindicated. This study evaluated the sensitivity of the real-time quaking-induced conversion (RT-QuIC) assay of recto-anal mucosa-associated lymphoid tissue (RAMALT) biopsy specimens and nasal brushings collected antemortem. These findings were compared to results of immunohistochemistry (IHC) analysis of ante- and postmortem samples. RAMALT samples were collected from populations of farmed and free-ranging Rocky Mountain elk (Cervus elaphus nelsoni; n = 323), and nasal brush samples were collected from a subpopulation of these animals (n = 205). We hypothesized that the sensitivity of RT-QuIC would be comparable to that of IHC analysis of RAMALT and would correspond to that of IHC analysis of postmortem tissues. We found RAMALT sensitivity (77.3%) to be highly correlative between RT-QuIC and IHC analysis. Sensitivity was lower when testing nasal brushings (34%), though both RAMALT and nasal brush test sensitivities were dependent on both the PRNP genotype and disease progression determined by the obex score. These data suggest that RT-QuIC, like IHC analysis, is a relatively sensitive assay for detection of CWD prions in RAMALT biopsy specimens and, with further investigation, has potential for large-scale and rapid automated testing of antemortem samples for CWD.

  5. Immunity to Salmonella typhi: considerations relevant to measurement of cellular immunity in typhoid-endemic regions.

    PubMed Central

    Murphy, J R; Wasserman, S S; Baqar, S; Schlesinger, L; Ferreccio, C; Lindberg, A A; Levine, M M

    1989-01-01

    Experiments were performed in Baltimore, Maryland and in Santiago, Chile, to determine the level of Salmonella typhi antigen-driven in vitro lymphocyte replication response which signifies specific acquired immunity to this bacterium and to determine the best method of data analysis and form of data presentation. Lymphocyte replication was measured as incorporation of 3H-thymidine into desoxyribonucleic acid. Data (ct/min/culture) were analyzed in raw form and following log transformation, by non-parametric and parametric statistical procedures. A preference was developed for log-transformed data and discriminant analysis. Discriminant analysis of log-transformed data revealed 3H-thymidine incorporation rates greater than 3,433 for particulate S. typhi, Ty2 antigen stimulated cultures signified acquired immunity at a sensitivity and specificity of 82.7; for soluble S. typhi O polysaccharide antigen-stimulated cultures, ct/min/culture values of greater than 1,237 signified immunity (sensitivity and specificity 70.5%). PMID:2702777

  6. Analysis of imazaquin in soybeans by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Guo, C; Hu, J-Y; Chen, X-Y; Li, J-Z

    2008-02-01

    An analytical method for the determination imazaquin residues in soybeans was developed. The developed liquid/liquid partition and strong anion exchange solid-phase extraction procedures provide the effective cleanup, removing the greatest number of sample matrix interferences. By optimizing mobile-phase pH water/acetonitrile conditions with phosphoric acid, using a C-18 reverse-phase chromatographic column and employing ultraviolet detection, excellent peak resolution was achieved. The combined cleanup and chromatographic method steps reported herein were sensitive and reliable for determining the imazaquin residues in soybean samples. This method is characterized by recovery >88.4%, precision <6.7% CV, and sensitivity of 0.005 ppm, in agreement with directives for method validation in residue analysis. Imazaquin residues in soybeans were further confirmed by high performance liquid chromatography-mass spectrometry (LC-MS). The proposed method was successfully applied to the analysis of imazaquin residues in soybean samples grown in an experimental field after treatments of imazaquin formulation.

  7. The Scaffold Attachment Factor SAFB1: A New Player in G2/M Checkpoint Control

    DTIC Science & Technology

    2007-04-01

    RNA was obtained from locally advanced breast tumors in 24 patients before they underwent four cycles of neoadjuvant docetaxel treatment . Gene...expression analysis was performed and correlated to the treatment response to determine genes that are differentially expressed in docetaxel-sensitive...decreased sensitivity to drugs, depending on the chemotherapeutic agent used 2) Association of SAFB1 loss with resistance to docetaxel treatment , both

  8. Sensitivity studies of pediatric material properties on juvenile lumbar spine responses using finite element analysis.

    PubMed

    Jebaseelan, D Davidson; Jebaraj, C; Yoganandan, Narayan; Rajasekaran, S; Kanna, Rishi M

    2012-05-01

    The objective of the study was to determine the sensitivity of material properties of the juvenile spine to its external and internal responses using a finite element model under compression, and flexion-extension bending moments. The methodology included exercising the 8-year-old juvenile lumbar spine using parametric procedures. The model included the vertebral centrum, growth plates, laminae, pedicles, transverse processes and spinous processes; disc annulus and nucleus; and various ligaments. The sensitivity analysis was conducted by varying the modulus of elasticity for various components. The first simulation was done using mean material properties. Additional simulations were done for each component corresponding to low and high material property variations. External displacement/rotation and internal stress-strain responses were determined under compression and flexion-extension bending. Results indicated that, under compression, disc properties were more sensitive than bone properties, implying an elevated role of the disc under this mode. Under flexion-extension moments, ligament properties were more dominant than the other components, suggesting that various ligaments of the juvenile spine play a key role in modulating bending behaviors. Changes in the growth plate stress associated with ligament properties explained the importance of the growth plate in the pediatric spine with potential implications in progressive deformities.

  9. Development of a reagentless electrochemiluminescent electrode for flow injection analysis using copolymerised luminol/aniline on nano-TiO2 functionalised indium-tin oxide glass.

    PubMed

    Liu, Chao; Wei, Xiuhua; Tu, Yifeng

    2013-07-15

    In this study, a nano-structured copolymer of luminol/aniline (PLA) was deposited onto nano-TiO2-functionalised indium tin oxide (ITO)-coated glass by electrochemical polymerisation using cyclic voltammetry (CV). The resulting reagentless electrochemiluminescent (ECL) electrode (ECLode) can be used for flow injection analysis (FIA). The properties of the ECLode were characterised by CV, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The ECLode has high background ECL emission as well as excellent stability and reproducibility, and yielding sensitive response towards target analytes. The ECL emissions of the ECLode were 50 times higher than PLA/ITO, and 500 times higher than polyluminol (PL)/ITO. The ECLode showed sensitive responses to reactive oxygen species (ROSs), permitting its application for determination of antioxidants by quenching. Under optimised conditions, an absolute detection limit of 69.9 pg was obtained for resveratrol, comparable to the highest levels of sensitivity achieved by other methods. Thus, the gross antioxidant content of red wine was determined, with satisfactory recoveries between 87.6% and 108.3%. These results suggest a bright future for the use of the ECLode for single-channel FIA due to its high sensitivity, accuracy and reproducibility. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Utilization of nuclear methods for materials analysis and the determination of concentration gradients

    NASA Technical Reports Server (NTRS)

    Darras, R.

    1979-01-01

    The various types of nuclear chemical analysis methods are discussed. The possibilities of analysis through activation and direct observation of nuclear reactions are described. Such methods make it possible to analyze trace elements and impurities with selectivity, accuracy, and a high degree of sensitivity. Such methods are used in measuring major elements present in materials which are available for analysis only in small quantities. These methods are well suited to superficial analyses and to determination of concentration gradients; provided the nature and energy of the incident particles are chosen judiciously. Typical examples of steels, pure iron and refractory metals are illustrated.

  11. Optimal cutoff points for HOMA-IR and QUICKI in the diagnosis of metabolic syndrome and non-alcoholic fatty liver disease: A population based study.

    PubMed

    Motamed, Nima; Miresmail, Seyed Javad Haji; Rabiee, Behnam; Keyvani, Hossein; Farahani, Behzad; Maadi, Mansooreh; Zamani, Farhad

    2016-03-01

    The present study was carried out to determine the optimal cutoff points for homeostatic model assessment (HOMA-IR) and quantitative insulin sensitivity check index (QUICKI) in the diagnosis of metabolic syndrome (MetS) and non-alcoholic fatty liver disease (NAFLD). The baseline data of 5511 subjects aged ≥18years of a cohort study in northern Iran were utilized to analyze. Receiver operating characteristic (ROC) analysis was conducted to determine the discriminatory capability of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. Youden index was utilized to determine the optimal cutoff points of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. The optimal cutoff points for HOMA-IR in the diagnosis of MetS and NAFLD were 2.0 [sensitivity=64.4%, specificity=66.8%] and 1.79 [sensitivity=66.2%, specificity=62.2%] in men and were 2.5 [sensitivity=57.6%, specificity=67.9%] and 1.95 [sensitivity=65.1%, specificity=54.7%] in women respectively. Furthermore, the optimal cutoff points for QUICKI in the diagnosis of MetS and NAFLD were 0.343 [sensitivity=63.7%, specificity=67.8%] and 0.347 [sensitivity=62.9%, specificity=65.0%] in men and were 0.331 [sensitivity=55.7%, specificity=70.7%] and 0.333 [sensitivity=53.2%, specificity=67.7%] in women respectively. Not only the optimal cutoff points of HOMA-IR and QUICKI were different for MetS and NAFLD, but also different cutoff points were obtained for men and women for each of these two conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Determination of fluorine concentrations using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry to analyze fluoride precipitates.

    NASA Astrophysics Data System (ADS)

    Lee, H. A.; Lee, J.; Kwon, E.; Kim, D.; Yoon, H. O.

    2015-12-01

    In recent times, fluorine has been receiving increasing attention due to the possibility for chemical (HF) leakage accidents and its high toxicity to human and environment. In this respect, a novel approach for the determination of fluorine concentrations in water samples using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry was investigated in this study. The main disadvantage of WDXRF technique for fluorine analysis is low analytical sensitivity for light elements with atomic number (Z) less than 15. To overcome this problem, we employed the precipitation reaction which fluoride is reacted with cation such as Al3+ and/or Ca2+ prior to WDXRF analysis because of their high analytical sensitivity. The cation was added in fluoride solutions to form precipitate (AlF3 and/or CaF2) and then the solution was filtered through Whatman filter. After drying at 60 °C for 5 min, the filter was coated with X-ray film and directly analyzed using WDXRF spectrometry. Consequently, we analyzed the cation on filter and subsequently fluorine concentration was calculated inversely based on chemical form of precipitate. This method can improve the analytical sensitivity of WDXRF technique for fluorine analysis and be applicable to various elements that can make precipitate.

  13. Blinded study determination of high sensitivity and specificity microchip electrophoresis–SSCP/HA to detect mutations in the p53 gene

    PubMed Central

    Hestekin, Christa N.; Lin, Jennifer S.; Senderowicz, Lionel; Jakupciak, John P.; O’Connell, Catherine; Rademaker, Alfred; Barron, Annelise E.

    2012-01-01

    Knowledge of the genetic changes that lead to disease has grown and continues to grow at a rapid pace. However, there is a need for clinical devices that can be used routinely to translate this knowledge into the treatment of patients. Use in a clinical setting requires high sensitivity and specificity (>97%) in order to prevent misdiagnoses. Single strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are two DNA-based, complementary methods for mutation detection that are inexpensive and relatively easy to implement. However, both methods are most commonly detected by slab gel electrophoresis, which can be labor-intensive, time-consuming, and often the methods are unable to produce high sensitivity and specificity without the use of multiple analysis conditions. Here we demonstrate the first blinded study using microchip electrophoresis-SSCP/HA. We demonstrate the ability of microchip electrophoresis-SSCP/HA to detect with 98% sensitivity and specificity >100 samples from the p53 gene exons 5–9 in a blinded study in an analysis time of less than 10 minutes. PMID:22002021

  14. Assessment of insulin sensitivity by the hyperinsulinemic euglycemic clamp: Comparison with the spectral analysis of photoplethysmography.

    PubMed

    De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte

    2017-01-01

    We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. A sensitivity analysis of regional and small watershed hydrologic models

    NASA Technical Reports Server (NTRS)

    Ambaruch, R.; Salomonson, V. V.; Simmons, J. W.

    1975-01-01

    Continuous simulation models of the hydrologic behavior of watersheds are important tools in several practical applications such as hydroelectric power planning, navigation, and flood control. Several recent studies have addressed the feasibility of using remote earth observations as sources of input data for hydrologic models. The objective of the study reported here was to determine how accurately remotely sensed measurements must be to provide inputs to hydrologic models of watersheds, within the tolerances needed for acceptably accurate synthesis of streamflow by the models. The study objective was achieved by performing a series of sensitivity analyses using continuous simulation models of three watersheds. The sensitivity analysis showed quantitatively how variations in each of 46 model inputs and parameters affect simulation accuracy with respect to five different performance indices.

  16. Error analysis applied to several inversion techniques used for the retrieval of middle atmospheric constituents from limb-scanning MM-wave spectroscopic measurements

    NASA Technical Reports Server (NTRS)

    Puliafito, E.; Bevilacqua, R.; Olivero, J.; Degenhardt, W.

    1992-01-01

    The formal retrieval error analysis of Rodgers (1990) allows the quantitative determination of such retrieval properties as measurement error sensitivity, resolution, and inversion bias. This technique was applied to five numerical inversion techniques and two nonlinear iterative techniques used for the retrieval of middle atmospheric constituent concentrations from limb-scanning millimeter-wave spectroscopic measurements. It is found that the iterative methods have better vertical resolution, but are slightly more sensitive to measurement error than constrained matrix methods. The iterative methods converge to the exact solution, whereas two of the matrix methods under consideration have an explicit constraint, the sensitivity of the solution to the a priori profile. Tradeoffs of these retrieval characteristics are presented.

  17. N-bromosuccinimide-fluorescein based sensitive flow-injection chemiluminescence determination of phenformin.

    PubMed

    Wang, Zhouping; Zhang, Zhujun; Fu, Zhifeng; Fang, Luqiu; Zhang, Xiao

    2004-02-01

    A novel and highly sensitive method for the determination of phenformin over the range of 6 x 10(-9) - 1 x 10(-5) g ml(-1) in pharmaceutical formulations with flow-injection chemiluminescence (CL) detection is proposed. The method is based on the CL produced during the oxidation of N-bromosuccinimide (NBS) in an alkaline medium in the presence of fluorescein as an effective energy transfer agent. The use of cetyltrimethylammonium bromide (CTAB) as a sensitizer enhances the signal magnitude by about 100 times. The detection limit is 2 x 10(-9) g ml(-1) (3sigma) with a relative standard deviation of 2.3% (n = 11) at 1 x 10(-7) g ml(-1) phenformin. Ninety samples can be determined per hour. The method was evaluated by carrying out a recovery study and by the analysis of commercial formulations. The obtained results compared well with those by an official method, and demonstrated good accuracy and precision. The possible CL mechanism of the proposed system was also briefly analyzed.

  18. Aerobic exercise training conserves insulin sensitivity for 1 yr following weight loss in overweight women.

    PubMed

    Fisher, Gordon; Hunter, Gary R; Gower, Barbara A

    2012-02-01

    The objectives of this study were to 1) identify the independent effects of exercise (aerobic or resistance training) and weight loss on whole body insulin sensitivity and 2) determine if aerobic or resistance training would be more successful for maintaining improved whole body insulin sensitivity 1 yr following weight loss. Subjects were 97 healthy, premenopausal women, body mass index (BMI) 27-30 kg/m(2). Following randomized assignment to one of three groups, diet only, diet + aerobic, or diet + resistance training until a BMI <25 kg/m(2) was achieved, body composition, fat distribution, and whole body insulin sensitivity were determined at baseline, in the weight reduced state, and at 1-yr follow up. The whole body insulin sensitivity index (S(I)) was determined using a frequently sampled intravenous glucose tolerance test. Results of repeated-measures ANOVA indicated a significant improvement in S(I) following weight loss. However, there were no group or group×time interactions. At 1-yr follow up, there were no significant time or group interactions for S(I;) however, there was a significant group×time interaction for S(I). Post hoc analysis revealed that women in the aerobic training group showed a significant increased S(I) from weight reduced to 1-yr follow up (P < 0.05), which was independent of intra-abdominal adipose tissue and %fat. No significant differences in S(I) from weight reduced to 1-yr follow up were observed for diet only or diet + resistance groups. Additionally, multiple linear regression analysis revealed that change in whole body insulin sensitivity from baseline to 1-yr follow up was independently associated with the change in Vo(2max) from baseline to 1-yr follow up (P < 0.05). These results suggest that long-term aerobic exercise training may conserve improvements in S(I) following weight loss and that maintaining cardiovascular fitness following weight loss may be important for maintaining improvements in S(I).

  19. Differentiation between diverticulitis and colorectal cancer: quantitative CT perfusion measurements versus morphologic criteria--initial experience.

    PubMed

    Goh, Vicky; Halligan, Steve; Taylor, Stuart A; Burling, David; Bassett, Paul; Bartram, Clive I

    2007-02-01

    To determine whether computed tomographic (CT) perfusion measurements in prospectively recruited patients can be used to differentiate between diverticulitis and colorectal cancer and to compare this discrimination with that of standard morphologic criteria. After institutional review board approval and written informed consent were obtained, 60 patients (24 men, 36 women; mean age, 69 years; range, 33.5-90.4 years; 20 patients with cancer, 20 with diverticulitis, and 20 with inactive diverticular disease) underwent CT perfusion imaging at the level of the colonic abnormality, and perfusion parameters were calculated. Analysis of variance was used to investigate any differences in perfusion between the patient groups. Two independent observers also analyzed an abdominopelvic CT study obtained immediately after the CT perfusion study and noted standard morphologic criteria for differential diagnosis. The sensitivity and specificity of CT perfusion measurements for determining the diagnostic category were compared with morphologic criteria by means of multivariate analysis to identify the most discriminatory criteria. Mean blood volume, blood flow, transit time, and permeability were significantly different between patients with cancer and those with diverticulitis (P < .0001); patients with cancer had the highest blood volume, blood flow, and permeability and the shortest transit time. The most discriminatory criteria for determining diagnostic category were blood volume, transit time, permeability, and presence of pericolonic nodes (P = .05, .02, .04, and .02, respectively). Blood volume and blood flow each had a sensitivity of 80% and had specificity of 70% and 75%, respectively, for cancer in comparison with standard morphologic criteria: less than 5 cm of bowel involvement (45% sensitivity, 95% specificity), presence of a mass (85% sensitivity, 90% specificity), pericolonic inflammation (75% sensitivity, 5% specificity), and pericolonic nodes (90% sensitivity, 45% specificity). CT perfusion measurements enable differentiation and better discrimination, in comparison with morphologic criteria, between cancer and diverticulitis. (c) RSNA, 2007.

  20. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.

    PubMed

    Sader, John E; Lu, Jianing; Mulvaney, Paul

    2014-11-01

    Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied - in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry - neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.

  1. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    PubMed

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  2. Sensitive determination of thiols in wine samples by a stable isotope-coded derivatization reagent d0/d4-acridone-10-ethyl-N-maleimide coupled with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry analysis.

    PubMed

    Lv, Zhengxian; You, Jinmao; Lu, Shuaimin; Sun, Weidi; Ji, Zhongyin; Sun, Zhiwei; Song, Cuihua; Chen, Guang; Li, Guoliang; Hu, Na; Zhou, Wu; Suo, Yourui

    2017-03-31

    As the key aroma compounds, varietal thiols are the crucial odorants responsible for the flavor of wines. Quantitative analysis of thiols can provide crucial information for the aroma profiles of different wine styles. In this study, a rapid and sensitive method for the simultaneous determination of six thiols in wine using d 0 /d 4 -acridone-10-ethyl-N-maleimide (d 0 /d 4 -AENM) as stable isotope-coded derivatization reagent (SICD) by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) has been developed. Quantification of thiols was performed by using d 4 -AENM labeled thiols as the internal standards (IS), followed by stable isotope dilution HPLC-ESI-MS/MS analysis. The AENM derivatization combined with multiple reactions monitoring (MRM) not only allowed trace analysis of thiols due to the extremely high sensitivity, but also efficiently corrected the matrix effects during HPLC-MS/MS and the fluctuation in MS/MS signal intensity due to instrument. The obtained internal standard calibration curves for six thiols were linear over the range of 25-10,000pmol/L (R 2 ≥0.9961). Detection limits (LODs) for most of analytes were below 6.3pmol/L. The proposed method was successfully applied for the simultaneous determination of six kinds of thiols in wine samples with precisions ≤3.5% and recoveries ≥78.1%. In conclusion, the developed method is expected to be a promising tool for detection of trace thiols in wine and also in other complex matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Mitochondrial sequence analysis for forensic identification using pyrosequencing technology.

    PubMed

    Andréasson, H; Asp, A; Alderborn, A; Gyllensten, U; Allen, M

    2002-01-01

    Over recent years, requests for mtDNA analysis in the field of forensic medicine have notably increased, and the results of such analyses have proved to be very useful in forensic cases where nuclear DNA analysis cannot be performed. Traditionally, mtDNA has been analyzed by DNA sequencing of the two hypervariable regions, HVI and HVII, in the D-loop. DNA sequence analysis using the conventional Sanger sequencing is very robust but time consuming and labor intensive. By contrast, mtDNA analysis based on the pyrosequencing technology provides fast and accurate results from the human mtDNA present in many types of evidence materials in forensic casework. The assay has been developed to determine polymorphic sites in the mitochondrial D-loop as well as the coding region to further increase the discrimination power of mtDNA analysis. The pyrosequencing technology for analysis of mtDNA polymorphisms has been tested with regard to sensitivity, reproducibility, and success rate when applied to control samples and actual casework materials. The results show that the method is very accurate and sensitive; the results are easily interpreted and provide a high success rate on casework samples. The panel of pyrosequencing reactions for the mtDNA polymorphisms were chosen to result in an optimal discrimination power in relation to the number of bases determined.

  4. Experimental and Theoretical Modal Analysis of Full-Sized Wood Composite Panels Supported on Four Nodes

    PubMed Central

    Guan, Cheng; Zhang, Houjiang; Wang, Xiping; Miao, Hu; Zhou, Lujing; Liu, Fenglu

    2017-01-01

    Key elastic properties of full-sized wood composite panels (WCPs) must be accurately determined not only for safety, but also serviceability demands. In this study, the modal parameters of full-sized WCPs supported on four nodes were analyzed for determining the modulus of elasticity (E) in both major and minor axes, as well as the in-plane shear modulus of panels by using a vibration testing method. The experimental modal analysis was conducted on three full-sized medium-density fiberboard (MDF) and three full-sized particleboard (PB) panels of three different thicknesses (12, 15, and 18 mm). The natural frequencies and mode shapes of the first nine modes of vibration were determined. Results from experimental modal testing were compared with the results of a theoretical modal analysis. A sensitivity analysis was performed to identify the sensitive modes for calculating E (major axis: Ex and minor axis: Ey) and the in-plane shear modulus (Gxy) of the panels. Mode shapes of the MDF and PB panels obtained from modal testing are in a good agreement with those from theoretical modal analyses. A strong linear relationship exists between the measured natural frequencies and the calculated frequencies. The frequencies of modes (2, 0), (0, 2), and (2, 1) under the four-node support condition were determined as the characteristic frequencies for calculation of Ex, Ey, and Gxy of full-sized WCPs. The results of this study indicate that the four-node support can be used in free vibration test to determine the elastic properties of full-sized WCPs. PMID:28773043

  5. Sensitivity Analysis Reveals Critical Factors that Affect Wetland Methane Emissions using Soil Biogeochemistry Model

    NASA Astrophysics Data System (ADS)

    Alonso-Contes, C.; Gerber, S.; Bliznyuk, N.; Duerr, I.

    2017-12-01

    Wetlands contribute approximately 20 to 40 % to global sources of methane emissions. We build a Methane model for tropical and subtropical forests, that allows inundated conditions, following the approaches used in more complex global biogeochemical emission models (LPJWhyMe and CLM4Me). The model was designed to replace model formulations with field and remotely sensed collected data for 2 essential drivers: plant productivity and hydrology. This allows us to directly focus on the central processes of methane production, consumption and transport. One of our long term goals is to make the model available to a scientists interested in including methane modeling in their location of study. Sensitivity analysis results help in focusing field data collection efforts. Here, we present results from a pilot global sensitivity analysis of the model order to determine which parameters and processes contribute most to the model's uncertainty of methane emissions. Results show that parameters related to water table behavior, carbon input (in form of plant productivity) and rooting depth affect simulated methane emissions the most. Current efforts include to perform the sensitivity analysis again on methane emissions outputs from an updated model that incorporates a soil heat flux routine and to determine the extent by which the soil temperature parameters affect CH4 emissions. Currently we are conducting field collection of data during Summer 2017 for comparison among 3 different landscapes located in the Ordway-Swisher Biological Station in Melrose, FL. We are collecting soil moisture and CH4 emission data from 4 different wetland types. Having data from 4 wetland types allows for calibration of the model to diverse soil, water and vegetation characteristics.

  6. Tumor invasiveness defined by IASLC/ATS/ERS classification of ground-glass nodules can be predicted by quantitative CT parameters.

    PubMed

    Zhou, Qian-Jun; Zheng, Zhi-Chun; Zhu, Yong-Qiao; Lu, Pei-Ji; Huang, Jia; Ye, Jian-Ding; Zhang, Jie; Lu, Shun; Luo, Qing-Quan

    2017-05-01

    To investigate the potential value of CT parameters to differentiate ground-glass nodules between noninvasive adenocarcinoma and invasive pulmonary adenocarcinoma (IPA) as defined by IASLC/ATS/ERS classification. We retrospectively reviewed 211 patients with pathologically proved stage 0-IA lung adenocarcinoma which appeared as subsolid nodules, from January 2012 to January 2013 including 137 pure ground glass nodules (pGGNs) and 74 part-solid nodules (PSNs). Pathological data was classified under the 2011 IASLC/ATS/ERS classification. Both quantitative and qualitative CT parameters were used to determine the tumor invasiveness between noninvasive adenocarcinomas and IPAs. There were 154 noninvasive adenocarcinomas and 57 IPAs. In pGGNs, CT size and area, one-dimensional mean CT value and bubble lucency were significantly different between noninvasive adenocarcinomas and IPAs on univariate analysis. Multivariate regression and ROC analysis revealed that CT size and one-dimensional mean CT value were predictive of noninvasive adenocarcinomas compared to IPAs. Optimal cutoff value was 13.60 mm (sensitivity, 75.0%; specificity, 99.6%), and -583.60 HU (sensitivity, 68.8%; specificity, 66.9%). In PSNs, there were significant differences in CT size and area, solid component area, solid proportion, one-dimensional mean and maximum CT value, three-dimensional (3D) mean CT value between noninvasive adenocarcinomas and IPAs on univariate analysis. Multivariate and ROC analysis showed that CT size and 3D mean CT value were significantly differentiators. Optimal cutoff value was 19.64 mm (sensitivity, 53.7%; specificity, 93.9%), -571.63 HU (sensitivity, 85.4%; specificity, 75.8%). For pGGNs, CT size and one-dimensional mean CT value are determinants for tumor invasiveness. For PSNs, tumor invasiveness can be predicted by CT size and 3D mean CT value.

  7. Global Sensitivity Applied to Dynamic Combined Finite Discrete Element Methods for Fracture Simulation

    NASA Astrophysics Data System (ADS)

    Godinez, H. C.; Rougier, E.; Osthus, D.; Srinivasan, G.

    2017-12-01

    Fracture propagation play a key role for a number of application of interest to the scientific community. From dynamic fracture processes like spall and fragmentation in metals and detection of gas flow in static fractures in rock and the subsurface, the dynamics of fracture propagation is important to various engineering and scientific disciplines. In this work we implement a global sensitivity analysis test to the Hybrid Optimization Software Suite (HOSS), a multi-physics software tool based on the combined finite-discrete element method, that is used to describe material deformation and failure (i.e., fracture and fragmentation) under a number of user-prescribed boundary conditions. We explore the sensitivity of HOSS for various model parameters that influence how fracture are propagated through a material of interest. The parameters control the softening curve that the model relies to determine fractures within each element in the mesh, as well a other internal parameters which influence fracture behavior. The sensitivity method we apply is the Fourier Amplitude Sensitivity Test (FAST), which is a global sensitivity method to explore how each parameter influence the model fracture and to determine the key model parameters that have the most impact on the model. We present several sensitivity experiments for different combination of model parameters and compare against experimental data for verification.

  8. Sensitivity Analysis of an ENteric Immunity SImulator (ENISI)-Based Model of Immune Responses to Helicobacter pylori Infection

    PubMed Central

    Alam, Maksudul; Deng, Xinwei; Philipson, Casandra; Bassaganya-Riera, Josep; Bisset, Keith; Carbo, Adria; Eubank, Stephen; Hontecillas, Raquel; Hoops, Stefan; Mei, Yongguo; Abedi, Vida; Marathe, Madhav

    2015-01-01

    Agent-based models (ABM) are widely used to study immune systems, providing a procedural and interactive view of the underlying system. The interaction of components and the behavior of individual objects is described procedurally as a function of the internal states and the local interactions, which are often stochastic in nature. Such models typically have complex structures and consist of a large number of modeling parameters. Determining the key modeling parameters which govern the outcomes of the system is very challenging. Sensitivity analysis plays a vital role in quantifying the impact of modeling parameters in massively interacting systems, including large complex ABM. The high computational cost of executing simulations impedes running experiments with exhaustive parameter settings. Existing techniques of analyzing such a complex system typically focus on local sensitivity analysis, i.e. one parameter at a time, or a close “neighborhood” of particular parameter settings. However, such methods are not adequate to measure the uncertainty and sensitivity of parameters accurately because they overlook the global impacts of parameters on the system. In this article, we develop novel experimental design and analysis techniques to perform both global and local sensitivity analysis of large-scale ABMs. The proposed method can efficiently identify the most significant parameters and quantify their contributions to outcomes of the system. We demonstrate the proposed methodology for ENteric Immune SImulator (ENISI), a large-scale ABM environment, using a computational model of immune responses to Helicobacter pylori colonization of the gastric mucosa. PMID:26327290

  9. Sensitivity Analysis of an ENteric Immunity SImulator (ENISI)-Based Model of Immune Responses to Helicobacter pylori Infection.

    PubMed

    Alam, Maksudul; Deng, Xinwei; Philipson, Casandra; Bassaganya-Riera, Josep; Bisset, Keith; Carbo, Adria; Eubank, Stephen; Hontecillas, Raquel; Hoops, Stefan; Mei, Yongguo; Abedi, Vida; Marathe, Madhav

    2015-01-01

    Agent-based models (ABM) are widely used to study immune systems, providing a procedural and interactive view of the underlying system. The interaction of components and the behavior of individual objects is described procedurally as a function of the internal states and the local interactions, which are often stochastic in nature. Such models typically have complex structures and consist of a large number of modeling parameters. Determining the key modeling parameters which govern the outcomes of the system is very challenging. Sensitivity analysis plays a vital role in quantifying the impact of modeling parameters in massively interacting systems, including large complex ABM. The high computational cost of executing simulations impedes running experiments with exhaustive parameter settings. Existing techniques of analyzing such a complex system typically focus on local sensitivity analysis, i.e. one parameter at a time, or a close "neighborhood" of particular parameter settings. However, such methods are not adequate to measure the uncertainty and sensitivity of parameters accurately because they overlook the global impacts of parameters on the system. In this article, we develop novel experimental design and analysis techniques to perform both global and local sensitivity analysis of large-scale ABMs. The proposed method can efficiently identify the most significant parameters and quantify their contributions to outcomes of the system. We demonstrate the proposed methodology for ENteric Immune SImulator (ENISI), a large-scale ABM environment, using a computational model of immune responses to Helicobacter pylori colonization of the gastric mucosa.

  10. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Mai, Juliane; Tolson, Bryan

    2017-04-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters or model processes. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method independency of the convergence testing method, we applied it to three widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991, Campolongo et al., 2000), the variance-based Sobol' method (Solbol' 1993, Saltelli et al. 2010) and a derivative-based method known as Parameter Importance index (Goehler et al. 2013). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. Subsequently, we focus on the model-independency by testing the frugal method using the hydrologic model mHM (www.ufz.de/mhm) with about 50 model parameters. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an efficient way. The appealing feature of this new technique is the necessity of no further model evaluation and therefore enables checking of already processed (and published) sensitivity results. This is one step towards reliable and transferable, published sensitivity results.

  11. Advanced techniques for determining long term compatibility of materials with propellants

    NASA Technical Reports Server (NTRS)

    Green, R. L.

    1972-01-01

    The search for advanced measurement techniques for determining long term compatibility of materials with propellants was conducted in several parts. A comprehensive survey of the existing measurement and testing technology for determining material-propellant interactions was performed. Selections were made from those existing techniques which were determined could meet or be made to meet the requirements. Areas of refinement or changes were recommended for improvement of others. Investigations were also performed to determine the feasibility and advantages of developing and using new techniques to achieve significant improvements over existing ones. The most interesting demonstration was that of the new technique, the volatile metal chelate analysis. Rivaling the neutron activation analysis in terms of sensitivity and specificity, the volatile metal chelate technique was fully demonstrated.

  12. Surface enhanced Raman spectroscopy for urinary tract infection diagnosis and antibiogram

    NASA Astrophysics Data System (ADS)

    Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Constantinos

    2010-02-01

    Urinary tract infection diagnosis and antibiogram require a minimum of 48 hours using standard laboratory practice. This long waiting period contributes to an increase in recurrent infections, rising health care costs, and a growing number of bacterial strains developing resistance to antibiotics. In this work, Surface Enhanced Raman Spectroscopy (SERS) was used as a novel method for classifying bacteria and determining their antibiogram. Five species of bacteria were classified with > 90% accuracy using their SERS spectra and a classification algorithm involving novel feature extraction and discriminant analysis. Antibiotic resistance or sensitivity was determined after just a two-hour exposure of bacteria to ciprofloxacin (sensitive) and amoxicillin (resistant) and analysis of their SERS spectra. These results can become the basis for the development of a novel method that would provide same day diagnosis and selection of the most appropriate antibiotic for most effective treatment of a urinary tract infection.

  13. BEVACIZUMAB LEVELS IN BREAST MILK AFTER LONG-TERM INTRAVITREAL INJECTIONS.

    PubMed

    McFarland, Trevor J; Rhoads, Andrew D; Hartzell, Matthew; Emerson, Geoffrey G; Bhavsar, Abdhish R; Stout, J Timothy

    2015-08-01

    The purpose of this study is to determine whether bevacizumab is detectable in the breast milk of nursing mothers. Breast milk samples were collected from 2 patients receiving monthly intravitreal bevacizumab injections for choroidal neovascularization over the course of 16 months. Enzyme-linked immunosorbent assay and Western blot analysis was used to determine the levels of bevacizumab in the milk samples. An enzyme-linked immunosorbent assay was developed using antibodies specific to bevacizumab in which the sensitivity threshold was 3 ng/mL. All breast milk samples assayed from the two patients actively undergoing treatment did not have detectable levels of bevacizumab. Samples collected 1.5 hours and 7 hours after an injection and 2 randomly chosen samples were negative by Western blot analysis. A sensitive assay to detect bevacizumab in breast milk samples assayed suggests that intravitreal injections do not result in detectable bevacizumab in breast milk.

  14. Simple and sensitive analysis of long-chain free fatty acids in milk by fluorogenic derivatization and high-performance liquid chromatography.

    PubMed

    Lu, Chi-Yu; Wu, Hsin-Lung; Chen, Su-Hwei; Kou, Hwang-Shang; Wu, Shou-Mei

    2002-01-02

    A highly sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of some important saturated and unsaturated fatty acids in milk, including lauric (dodecanoic), myristic (tetradecanoic), palmitic (hexadecanoic), stearic (octadecanoic), palmitoleic (hexadecenoic), oleic (octadecenoic), and linoleic acids (octadecadienoic acids). The fatty acids were fluorogenically derivatized with 2-(2-naphthoxy)ethyl 2-(piperidino)ethanesulfonate (NOEPES) as their naphthoxyethyl derivatives. The resulting derivatives were separated by isocratic HPLC and monitored with a fluorometric detector (lambdaex = 235 nm, lambdaem = 350 nm). The fatty acids in milk were extracted with toluene, and the extract with the fatty acids was directly derivatized with NOEPES without solvent replacement. Determination of long-chain free fatty acids in milk is feasible by a standard addition method. A small amount of milk product, 10 microL, is sufficient for the analysis.

  15. Mercury and gold concentrations of highly polluted environmental samples determined using prompt gamma-ray analysis and instrument neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Osawa, Takahito; Hatsukawa, Yuichi; Appel, Peter W. U.; Matsue, Hideaki

    2011-04-01

    The authors have established a method of determining mercury and gold in severely polluted environmental samples using prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA). Since large amounts of mercury are constantly being released into the environment by small-scale gold mining in many developing countries, the mercury concentration in tailings and water has to be determined to mitigate environmental pollution. Cold-vapor atomic absorption analysis, the most pervasive method of mercury analysis, is not suitable because tailings and water around mining facilities have extremely high mercury concentrations. On the other hand, PGA can determine high mercury concentrations in polluted samples as it has an appropriate level of sensitivity. Moreover, gold concentrations can be determined sequentially by using INAA after PGA. In conclusion, the analytical procedure established in this work using PGA and INAA is the best way to evaluate the degree of pollution and the tailing resource value. This method will significantly contribute to mitigating problems in the global environment.

  16. Ethanol-nicotine interactions in long-sleep and short-sleep mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Fiebre, C.M.; Marks, M.J.; Collins, A.C.

    The possibility that common genetic factors regulate initial sensitivities to ethanol and nicotine as well as the development of cross-tolerance between these agents was explored using the long-sleep (LS) and short-sleep (SS) mice. The LS mice proved to be more sensitive to an acute challenge with nicotine than were the SS mice. Segregation analysis (F1, F2, backcross) indicated that ethanol sensitivity and nicotine sensitivity segregate together. Acute pretreatment with nicotine did not significantly affect sensitivity to ethanol, but ethanol pretreatment altered nicotine responsiveness. The LS mice develop more tolerance to nicotine and ethanol than do the SS and they alsomore » develop more cross-tolerance. These genetically determined differences in initial sensitivities, and tolerance and cross-tolerance development are not readily explained by differences in brain nicotinic receptor numbers.« less

  17. Fast and sensitive determination of per- and polyfluoroalkyl substances in seawater.

    PubMed

    Concha-Graña, Estefanía; Fernández-Martínez, Gerardo; López-Mahía, Purificación; Prada-Rodríguez, Darío; Muniategui-Lorenzo, Soledad

    2018-06-22

    In this work, a novel, fast, and sensitive method was developed for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS) and PFOS precursor's determination in seawater. The proposed method consists in a vortex-assisted liquid-liquid microextraction (VALLME) combined with liquid chromatography (LC) and LTQ-Orbitrap high resolution mass spectrometry (LTQ-Orbitrap HRMS) determination. Several parameters affecting both the HPLC-LTQ Orbitrap HRMS determination and the VALLME were studied, with special attention to blank contamination problem. The use of LTQ-Orbitrap-HRMS in full mode, quantifying the target analytes using the exact mass, provides a very powerful detection in terms of sensitivity and specificity maintaining all the information provided by the full mass spectra, allowing, also, the identification of non-target substances. The use of matrix-matched calibration, together with labelled surrogate standards, minimize matrix effects and compensate potential recovery losses, resulting in recoveries between 95 and 105%, with excellent sensitivity (quantitation limit between 0.7 and 6 ng L -1 ) and precision (4-10%). The proposed method requires only 35 mL of sample and 100 μL of extracting solvent, is fast and avoids the use of other solvents to obtain the dispersive cloudy solution, simplifying the procedure and improving the existing procedures for the determination of per- and polyfluoroalkyl substances (PFASs) in seawater in terms of green analytical chemistry. The method was successfully validated by participating in a proficiency test assay provided by the National Measurement Institute of the Australian Government for the determination of PFOA, total PFOS and linear PFOS in waters. A revision of the state of the art in the last twelve years of methods for the analysis of PFASs in seawater and other types of water was performed, and a critical comparison between the developed method and the previously published was included. Finally, the method was applied to the analysis of samples from Ría de Vigo, a sensitive and semiconfined coastal area located in the northwest of Spain. PFOS, N-methyl perfluorooctanesulfonamide (n-MeFOSA) and N-ethyl perfluorooctanesulfonamide (n-EtFOSA) were detected in samples at levels lower than the maximum allowable concentration (MAC) established by Directive 2013/39/EU, but above the annual average (AA) levels. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. 7 CFR 1710.303 - Power cost studies-power supply borrowers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... contracts or revisions to existing contracts, and an analysis of the effects on power costs; (4) Use of sensitivity analyses to determine the vulnerability of the alternatives to a reasonable range of assumptions... conservation alternatives as set forth in §§ 1710.253 and 1710.254; (2) A present-value analysis of the costs...

  19. Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria

    PubMed Central

    Correia, Rodolfo Patussi; Bento, Laiz Cameirão; Bortolucci, Ana Carolina Apelle; Alexandre, Anderson Marega; Vaz, Andressa da Costa; Schimidell, Daniela; Pedro, Eduardo de Carvalho; Perin, Fabricio Simões; Nozawa, Sonia Tsukasa; Mendes, Cláudio Ernesto Albers; Barroso, Rodrigo de Souza; Bacal, Nydia Strachman

    2016-01-01

    ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones. PMID:27759825

  20. The diagnostic value of narrow-band imaging for early and invasive lung cancer: a meta-analysis.

    PubMed

    Zhu, Juanjuan; Li, Wei; Zhou, Jihong; Chen, Yuqing; Zhao, Chenling; Zhang, Ting; Peng, Wenjia; Wang, Xiaojing

    2017-07-01

    This study aimed to compare the ability of narrow-band imaging to detect early and invasive lung cancer with that of conventional pathological analysis and white-light bronchoscopy. We searched the PubMed, EMBASE, Sinomed, and China National Knowledge Infrastructure databases for relevant studies. Meta-disc software was used to perform data analysis, meta-regression analysis, sensitivity analysis, and heterogeneity testing, and STATA software was used to determine if publication bias was present, as well as to calculate the relative risks for the sensitivity and specificity of narrow-band imaging vs those of white-light bronchoscopy for the detection of early and invasive lung cancer. A random-effects model was used to assess the diagnostic efficacy of the above modalities in cases in which a high degree of between-study heterogeneity was noted with respect to their diagnostic efficacies. The database search identified six studies including 578 patients. The pooled sensitivity and specificity of narrow-band imaging were 86% (95% confidence interval: 83-88%) and 81% (95% confidence interval: 77-84%), respectively, and the pooled sensitivity and specificity of white-light bronchoscopy were 70% (95% confidence interval: 66-74%) and 66% (95% confidence interval: 62-70%), respectively. The pooled relative risks for the sensitivity and specificity of narrow-band imaging vs the sensitivity and specificity of white-light bronchoscopy for the detection of early and invasive lung cancer were 1.33 (95% confidence interval: 1.07-1.67) and 1.09 (95% confidence interval: 0.84-1.42), respectively, and sensitivity analysis showed that narrow-band imaging exhibited good diagnostic efficacy with respect to detecting early and invasive lung cancer and that the results of the study were stable. Narrow-band imaging was superior to white light bronchoscopy with respect to detecting early and invasive lung cancer; however, the specificities of the two modalities did not differ significantly.

  1. Colorado River basin sensitivity to disturbance impacts

    NASA Astrophysics Data System (ADS)

    Bennett, K. E.; Urrego-Blanco, J. R.; Jonko, A. K.; Vano, J. A.; Newman, A. J.; Bohn, T. J.; Middleton, R. S.

    2017-12-01

    The Colorado River basin is an important river for the food-energy-water nexus in the United States and is projected to change under future scenarios of increased CO2emissions and warming. Streamflow estimates to consider climate impacts occurring as a result of this warming are often provided using modeling tools which rely on uncertain inputs—to fully understand impacts on streamflow sensitivity analysis can help determine how models respond under changing disturbances such as climate and vegetation. In this study, we conduct a global sensitivity analysis with a space-filling Latin Hypercube sampling of the model parameter space and statistical emulation of the Variable Infiltration Capacity (VIC) hydrologic model to relate changes in runoff, evapotranspiration, snow water equivalent and soil moisture to model parameters in VIC. Additionally, we examine sensitivities of basin-wide model simulations using an approach that incorporates changes in temperature, precipitation and vegetation to consider impact responses for snow-dominated headwater catchments, low elevation arid basins, and for the upper and lower river basins. We find that for the Colorado River basin, snow-dominated regions are more sensitive to uncertainties. New parameter sensitivities identified include runoff/evapotranspiration sensitivity to albedo, while changes in snow water equivalent are sensitive to canopy fraction and Leaf Area Index (LAI). Basin-wide streamflow sensitivities to precipitation, temperature and vegetation are variable seasonally and also between sub-basins; with the largest sensitivities for smaller, snow-driven headwater systems where forests are dense. For a major headwater basin, a 1ºC of warming equaled a 30% loss of forest cover, while a 10% precipitation loss equaled a 90% forest cover decline. Scenarios utilizing multiple disturbances led to unexpected results where changes could either magnify or diminish extremes, such as low and peak flows and streamflow timing, dependent on the strength and direction of the forcing. These results indicate the importance of understanding model sensitivities under disturbance impacts to manage these shifts; plan for future water resource changes and determine how the impacts will affect the sustainability and adaptability of food-energy-water systems.

  2. Immunohistochemical expression of insulin, glucagon, and somatostatin in pancreatic islets of horses with and without insulin resistance.

    PubMed

    Newkirk, Kim M; Ehrensing, Gordon; Odoi, Agricola; Boston, Raymond C; Frank, Nicholas

    2018-02-01

    OBJECTIVE To assess insulin, glucagon, and somatostatin expression within pancreatic islets of horses with and without insulin resistance. ANIMALS 10 insulin-resistant horses and 13 insulin-sensitive horses. PROCEDURES For each horse, food was withheld for at least 10 hours before a blood sample was collected for determination of serum insulin concentration. Horses with a serum insulin concentration < 20 μU/mL were assigned to the insulin-sensitive group, whereas horses with a serum insulin concentration > 20 μU/mL underwent a frequently sampled IV glucose tolerance test to determine sensitivity to insulin by minimal model analysis. Horses with a sensitivity to insulin < 1.0 × 10 -4 L•min -1 •mU -1 were assigned to the insulin-resistant group. All horses were euthanized with a barbiturate overdose, and pancreatic specimens were harvested and immunohistochemically stained for determination of insulin, glucagon, and somatostatin expression in pancreatic islets. Islet hormone expression was compared between insulin-resistant and insulin-sensitive horses. RESULTS Cells expressing insulin, glucagon, and somatostatin made up approximately 62%, 12%, and 7%, respectively, of pancreatic islet cells in insulin-resistant horses and 64%, 18%, and 9%, respectively, of pancreatic islet cells in insulin-sensitive horses. Expression of insulin and somatostatin did not differ between insulin-resistant and insulin-sensitive horses, but the median percentage of glucagon-expressing cells in the islets of insulin-resistant horses was significantly less than that in insulin-sensitive horses. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that, in insulin-resistant horses, insulin secretion was not increased but glucagon production might be downregulated as a compensatory response to hyperinsulinemia.

  3. Development of a Self-Determination Measure for College Students: Validity Evidence for the Basic Needs Satisfaction at College Scale

    ERIC Educational Resources Information Center

    Jenkins-Guarnieri, Michael A.; Vaughan, Angela L.; Wright, Stephen L.

    2015-01-01

    We adapted a work self-determination measure to create the Basic Needs Satisfaction at College Scale. Confirmatory factor analysis and item response theory analyses with data from 525 adults supported a 3-factor model with 13 items most sensitive for lower to middle range levels of the autonomy, competence, and relatedness constructs.

  4. Space station electrical power system availability study

    NASA Technical Reports Server (NTRS)

    Turnquist, Scott R.; Twombly, Mark A.

    1988-01-01

    ARINC Research Corporation performed a preliminary reliability, and maintainability (RAM) anlaysis of the NASA space station Electric Power Station (EPS). The analysis was performed using the ARINC Research developed UNIRAM RAM assessment methodology and software program. The analysis was performed in two phases: EPS modeling and EPS RAM assessment. The EPS was modeled in four parts: the insolar power generation system, the eclipse power generation system, the power management and distribution system (both ring and radial power distribution control unit (PDCU) architectures), and the power distribution to the inner keel PDCUs. The EPS RAM assessment was conducted in five steps: the use of UNIRAM to perform baseline EPS model analyses and to determine the orbital replacement unit (ORU) criticalities; the determination of EPS sensitivity to on-orbit spared of ORUs and the provision of an indication of which ORUs may need to be spared on-orbit; the determination of EPS sensitivity to changes in ORU reliability; the determination of the expected annual number of ORU failures; and the integration of the power generator system model results with the distribution system model results to assess the full EPS. Conclusions were drawn and recommendations were made.

  5. A Sensitive Photometric Procedure for Cobalt Determination in Water Employing a Compact Multicommuted Flow Analysis System.

    PubMed

    da Silva Magalhães, Ticiane; Reis, Boaventura F

    2017-09-01

    In this work, a multicommuted flow analysis procedure is proposed for the spectrophotometric determination of cobalt in fresh water, employing an instrument setup of downsized dimension and improved cost-effectiveness. The method is based on the catalytic effect of Co(II) on the Tiron oxidation by hydrogen peroxide in alkaline medium, forming a complex that absorbs radiation at 425 nm. The photometric detection was accomplished using a homemade light-emitting-diode (LED)-based photometer designed to use a flow cell with an optical path-length of 100 mm to improve sensitivity. After selecting adequate values for the flow system variables, adherence to the Beer-Lambert-Bouguer law was observed for standard solution concentrations in the range of 0.13-1.5 µg L -1 Co(II). Other useful features including a relative standard deviation of 2.0% (n = 11) for a sample with 0.49 µg L -1 Co(II), a detection limit of 0.06 µg L -1 Co(II) (n = 20), an analytical frequency of 42 sample determinations per hour, and waste generation of 1.5 mL per determination were achieved.

  6. How the definition of acceptable antigens and epitope analysis can facilitate transplantation of highly sensitized patients with excellent long-term graft survival.

    PubMed

    Heidt, Sebastiaan; Haasnoot, Geert W; Claas, Frans H J

    2018-05-24

    Highly sensitized patients awaiting a renal transplant have a low chance of receiving an organ offer. Defining acceptable antigens and using this information for allocation purposes can vastly enhance transplantation of this subgroup of patients, which is the essence of the Eurotransplant Acceptable Mismatch program. Acceptable antigens can be determined by extensive laboratory testing, as well as on basis of human leukocyte antigen (HLA) epitope analyses. Within the Acceptable Mismatch program, there is no effect of HLA mismatches on long-term graft survival. Furthermore, patients transplanted through the Acceptable Mismatch program have similar long-term graft survival to nonsensitized patients transplanted through regular allocation. Although HLA epitope analysis is already being used for defining acceptable HLA antigens for highly sensitized patients in the Acceptable Mismatch program, increasing knowledge on HLA antibody - epitope interactions will pave the way toward the definition of acceptable epitopes for highly sensitized patients in the future. Allocation based on acceptable antigens can facilitate transplantation of highly sensitized patients with excellent long-term graft survival.

  7. Comparison of the sensitivity of mass spectrometry atmospheric pressure ionization techniques in the analysis of porphyrinoids.

    PubMed

    Swider, Paweł; Lewtak, Jan P; Gryko, Daniel T; Danikiewicz, Witold

    2013-10-01

    The porphyrinoids chemistry is greatly dependent on the data obtained in mass spectrometry. For this reason, it is essential to determine the range of applicability of mass spectrometry ionization methods. In this study, the sensitivity of three different atmospheric pressure ionization techniques, electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization, was tested for several porphyrinods and their metallocomplexes. Electrospray ionization method was shown to be the best ionization technique because of its high sensitivity for derivatives of cyanocobalamin, free-base corroles and porphyrins. In the case of metallocorroles and metalloporphyrins, atmospheric pressure photoionization with dopant proved to be the most sensitive ionization method. It was also shown that for relatively acidic compounds, particularly for corroles, the negative ion mode provides better sensitivity than the positive ion mode. The results supply a lot of relevant information on the methodology of porphyrinoids analysis carried out by mass spectrometry. The information can be useful in designing future MS or liquid chromatography-MS experiments. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Non-invasive tool for foetal sex determination in early gestational age.

    PubMed

    Mortarino, M; Garagiola, I; Lotta, L A; Siboni, S M; Semprini, A E; Peyvandi, F

    2011-11-01

    Free foetal DNA in maternal blood during early pregnancy is an ideal source of foetal genetic material for non-invasive prenatal diagnosis. The aim of this study was to evaluate the use of free foetal DNA analysis at early gestational age as pretest for the detection of specific Y-chromosome sequences in maternal plasma of women who are carriers of X-linked disorders, such as haemophilia. Real-time quantitative PCR analysis of maternal plasma was performed for the detection of the SRY or DYS14 sequence. A group of 208 pregnant women, at different gestational periods from 4 to 12 weeks, were tested to identify the optimal period to obtain an adequate amount of foetal DNA for prenatal diagnosis. Foetal gender was determined in 181 pregnant women sampled throughout pregnancy. Pregnancy outcome and foetal gender were confirmed using karyotyping, ultrasonography or after birth. The sensitivity, which was low between 4th and 7th week (mean 73%), increased significantly after 7+1th weeks of gestation (mean 94%). The latter sensitivity after 7+1th week of gestation is associated to a high specificity (100%), with an overall accuracy of 96% for foetal gender determination. This analysis demonstrates that foetal gender determination in maternal plasma is reliable after the 9th week of gestation and it can be used, in association with ultrasonography, for screening to determine the need for chorionic villus sampling for prenatal diagnosis of X-linked disorders, such as haemophilia. © 2011 Blackwell Publishing Ltd.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, M; Finlay, J; Zhu, T

    Purpose: Photosensitizer concentration during photodynamic therapy (PDT) is an important parameter for accurate dosimetry. Fluorescence signal can be used as a measure of photosensitizer concentration. Two methods of data acquisition were compared to an ex vivo study both for in vivo and phantom models. Methods: Fluorescence signal of commonly used photosensitizer benzoporphyrin derivative monoacid ring A (BPD) was obtained in phantoms and mouse tumors using an excitation light of 405 nm. Interstitial fluorescence signal was obtained using a side-cut fiber inserted into the tumor tissue of interest. Using a previously developed multi-fiber probe, tumor surface fluorescence measurements were also collected.more » Signals were calibrated according to optical phantoms with known sensitizer fluorescence. Optical properties for each sample were determined and the influence of different absorption and scattering properties on the fluorescence signals was investigated. Using single value decomposition of the spectra, the sensitizer concentration was determined using the two different measurement geometries. An ex vivo analysis was also performed for tumor samples to determine the sensitizer concentration. Results: The two fluorescence signals obtained from the surface multi-fiber probe and the interstitial measurements were compared and were corresponding for both phantoms and mouse models. The values obtained were comparable to the ex vivo measurements as well. Despite the difference in geometry, the surface probe measurements can still be used as a metric for determining the presence of sensitizer in small volume tumors. Conclusion: The multi-fiber contact probe can be used as a tool to measure fluorescence at the surface of the treatment area for PDT and predict sensitizer concentration throughout the tumor. This is advantageous in that the measurement does not damage any tissue. Future work will include investigating the dependence of these results on intratumor sensitizer distribution.« less

  10. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G.

    PubMed

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 x 10(-6) to 1.0 x 10(-4) mol l(-1) and the detection limit for ferulic acid was 8.7 x 10(-9) mol l(-1). The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 x 10(-5) mol l(-1) ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  11. Chemiluminescence determination of ferulic acid by flow-injection analysis using cerium(IV) sensitized by rhodamine 6G

    NASA Astrophysics Data System (ADS)

    Wang, Ju Peng; Li, Nian Bing; Luo, Hong Qun

    2008-11-01

    A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0 × 10 -6 to 1.0 × 10 -4 mol l -1 and the detection limit for ferulic acid was 8.7 × 10 -9 mol l -1. The relative standard deviation was 2.4% for 10 replicate analyses of 1.0 × 10 -5 mol l -1 ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results.

  12. Determining the Best Treatment for Coronal Angular Deformity of the Knee Joint in Growing Children: A Decision Analysis

    PubMed Central

    Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Choi, In Ho; Cho, Tae-Joon; Yoo, Won Joon; Park, Moon Seok

    2014-01-01

    This study aimed to determine the best treatment modality for coronal angular deformity of the knee joint in growing children using decision analysis. A decision tree was created to evaluate 3 treatment modalities for coronal angular deformity in growing children: temporary hemiepiphysiodesis using staples, percutaneous screws, or a tension band plate. A decision analysis model was constructed containing the final outcome score, probability of metal failure, and incomplete correction of deformity. The final outcome was defined as health-related quality of life and was used as a utility in the decision tree. The probabilities associated with each case were obtained by literature review, and health-related quality of life was evaluated by a questionnaire completed by 25 pediatric orthopedic experts. Our decision analysis model favored temporary hemiepiphysiodesis using a tension band plate over temporary hemiepiphysiodesis using percutaneous screws or stapling, with utilities of 0.969, 0.957, and 0.962, respectively. One-way sensitivity analysis showed that hemiepiphysiodesis using a tension band plate was better than temporary hemiepiphysiodesis using percutaneous screws, when the overall complication rate of hemiepiphysiodesis using a tension band plate was lower than 15.7%. Two-way sensitivity analysis showed that hemiepiphysiodesis using a tension band plate was more beneficial than temporary hemiepiphysiodesis using percutaneous screws. PMID:25276801

  13. Thermodynamic Analysis of a Coupled Chemical Reaction.

    ERIC Educational Resources Information Center

    Trimm, Harold; And Others

    1979-01-01

    Describes a typical relaxation kinetic experiment using a sudden increase in the temperature of the system. Time involved is described as minimal and the approach as quicker, more accurate, sensitive, and producing simultaneous determination of several thermodynamic parameters. (Author/SA)

  14. Development of a Terbium-Sensitized Fluorescence Method for Analysis of Silibinin.

    PubMed

    Ershadi, Saba; Jouyban, Abolghasem; Molavi, Ommoleila; Shayanfar, Ali

    2017-05-01

    Silibinin is a natural flavonoid with potent anticancer properties, as shown in both in vitro and in vivo experiments. Various methods have been used for silibinin analysis. Terbium-sensitized fluorescence methods have been widely used for the determination of drugs in pharmaceutical preparations and biological samples in recent years. The present work is aimed at providing a simple analytical method for the quantitative determination of silibinin in aqueous solutions based on the formation of a fluorescent complex with terbium ion. Terbium concentration, pH, and volume of buffer, the important effective parameters for the determination of silibinin by the proposed method, were optimized using response surface methodology. The fluorescence intensity of silibinin was measured at 545 nm using λex = 334 nm. The developed method was applied for the determination of silibinin in plasma samples after protein precipitation with acetone. Under optimum conditions, the method provided a linear range between 0.10 and 0.50 mg/L, with a coefficient of determination (R2) of 0.997. The LOD and LOQ were 0.034 and 0.112 mg/L, respectively. These results indicate that the developed method is a simple, low-cost, and suitable analytical method for the quantification of silibinin in aqueous solution and plasma samples.

  15. Parameter sensitivity analysis of a 1-D cold region lake model for land-surface schemes

    NASA Astrophysics Data System (ADS)

    Guerrero, José-Luis; Pernica, Patricia; Wheater, Howard; Mackay, Murray; Spence, Chris

    2017-12-01

    Lakes might be sentinels of climate change, but the uncertainty in their main feedback to the atmosphere - heat-exchange fluxes - is often not considered within climate models. Additionally, these fluxes are seldom measured, hindering critical evaluation of model output. Analysis of the Canadian Small Lake Model (CSLM), a one-dimensional integral lake model, was performed to assess its ability to reproduce diurnal and seasonal variations in heat fluxes and the sensitivity of simulated fluxes to changes in model parameters, i.e., turbulent transport parameters and the light extinction coefficient (Kd). A C++ open-source software package, Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), was used to perform sensitivity analysis (SA) and identify the parameters that dominate model behavior. The generalized likelihood uncertainty estimation (GLUE) was applied to quantify the fluxes' uncertainty, comparing daily-averaged eddy-covariance observations to the output of CSLM. Seven qualitative and two quantitative SA methods were tested, and the posterior likelihoods of the modeled parameters, obtained from the GLUE analysis, were used to determine the dominant parameters and the uncertainty in the modeled fluxes. Despite the ubiquity of the equifinality issue - different parameter-value combinations yielding equivalent results - the answer to the question was unequivocal: Kd, a measure of how much light penetrates the lake, dominates sensible and latent heat fluxes, and the uncertainty in their estimates is strongly related to the accuracy with which Kd is determined. This is important since accurate and continuous measurements of Kd could reduce modeling uncertainty.

  16. Determination of subthalamic nucleus location by quantitative analysis of despiked background neural activity from microelectrode recordings obtained during deep brain stimulation surgery.

    PubMed

    Danish, Shabbar F; Baltuch, Gordon H; Jaggi, Jurg L; Wong, Stephen

    2008-04-01

    Microelectrode recording during deep brain stimulation surgery is a useful adjunct for subthalamic nucleus (STN) localization. We hypothesize that information in the nonspike background activity can help identify STN boundaries. We present results from a novel quantitative analysis that accomplishes this goal. Thirteen consecutive microelectrode recordings were retrospectively analyzed. Spikes were removed from the recordings with an automated algorithm. The remaining "despiked" signals were converted via root mean square amplitude and curve length calculations into "feature profile" time series. Subthalamic nucleus boundaries determined by inspection, based on sustained deviations from baseline for each feature profile, were compared against those determined intraoperatively by the clinical neurophysiologist. Feature profile activity within STN exhibited a sustained rise in 10 of 13 tracks (77%). The sensitivity of STN entry was 60% and 90% for curve length and root mean square amplitude, respectively, when agreement within 0.5 mm of the neurophysiologist's prediction was used. Sensitivities were 70% and 100% for 1 mm accuracy. Exit point sensitivities were 80% and 90% for both features within 0.5 mm and 1.0 mm, respectively. Reproducible activity patterns in deep brain stimulation microelectrode recordings can allow accurate identification of STN boundaries. Quantitative analyses of this type may provide useful adjunctive information for electrode placement in deep brain stimulation surgery.

  17. Estuarine sediment toxicity tests on diatoms: Sensitivity comparison for three species

    NASA Astrophysics Data System (ADS)

    Moreno-Garrido, Ignacio; Lubián, Luis M.; Jiménez, Begoña; Soares, Amadeu M. V. M.; Blasco, Julián

    2007-01-01

    Experimental populations of three marine and estuarine diatoms were exposed to sediments with different levels of pollutants, collected from the Aveiro Lagoon (NW of Portugal). The species selected were Cylindrotheca closterium, Phaeodactylum tricornutum and Navicula sp. Previous experiments were designed to determine the influence of the sediment particle size distribution on growth of the species assayed. Percentage of silt-sized sediment affect to growth of the selected species in the experimental conditions: the higher percentage of silt-sized sediment, the lower growth. In any case, percentages of silt-sized sediment less than 10% did not affect growth. In general, C. closterium seems to be slightly more sensitive to the selected sediments than the other two species. Two groups of sediment samples were determined as a function of the general response of the exposed microalgal populations: three of the six samples used were more toxic than the other three. Chemical analysis of the samples was carried out in order to determine the specific cause of differences in toxicity. After a statistical analysis, concentrations of Sn, Zn, Hg, Cu and Cr (among all physico-chemical analyzed parameters), in order of importance, were the most important factors that divided the two groups of samples (more and less toxic samples). Benthic diatoms seem to be sensitive organisms in sediment toxicity tests. Toxicity data from bioassays involving microphytobentos should be taken into account when environmental risks are calculated.

  18. SPR based hybrid electro-optic biosensor for β-lactam antibiotics determination in water

    NASA Astrophysics Data System (ADS)

    Galatus, Ramona; Feier, Bogdan; Cristea, Cecilia; Cennamo, Nunzio; Zeni, Luigi

    2017-09-01

    The present work aims to provide a hybrid platform capable of complementary and sensitive detection of β-lactam antibiotics, ampicillin in particular. The use of an aptamer specific to ampicillin assures good selectivity and sensitivity for the detection of ampicillin from different matrice. This new approach is dedicated for a portable, remote sensing platform based on low-cost, small size and low-power consumption solution. The simple experimental hybrid platform integrates the results from the D-shape surface plasmon resonance plastic optical fiber (SPR-POF) and from the electrochemical (bio)sensor, for the analysis of ampicillin, delivering sensitive and reliable results. The SPR-POF already used in many previous applications is embedded in a new experimental setup with fluorescent fibers emitters, for broadband wavelength analysis, low-power consumption and low-heating capabilities of the sensing platform.

  19. Mechanical performance and parameter sensitivity analysis of 3D braided composites joints.

    PubMed

    Wu, Yue; Nan, Bo; Chen, Liang

    2014-01-01

    3D braided composite joints are the important components in CFRP truss, which have significant influence on the reliability and lightweight of structures. To investigate the mechanical performance of 3D braided composite joints, a numerical method based on the microscopic mechanics is put forward, the modeling technologies, including the material constants selection, element type, grid size, and the boundary conditions, are discussed in detail. Secondly, a method for determination of ultimate bearing capacity is established, which can consider the strength failure. Finally, the effect of load parameters, geometric parameters, and process parameters on the ultimate bearing capacity of joints is analyzed by the global sensitivity analysis method. The results show that the main pipe diameter thickness ratio γ, the main pipe diameter D, and the braided angle α are sensitive to the ultimate bearing capacity N.

  20. A closure test for time-specific capture-recapture data

    USGS Publications Warehouse

    Stanley, T.R.; Burnham, K.P.

    1999-01-01

    The assumption of demographic closure in the analysis of capture-recapture data under closed-population models is of fundamental importance. Yet, little progress has been made in the development of omnibus tests of the closure assumption. We present a closure test for time-specific data that, in principle, tests the null hypothesis of closed-population model M(t) against the open-population Jolly-Seber model as a specific alternative. This test is chi-square, and can be decomposed into informative components that can be interpreted to determine the nature of closure violations. The test is most sensitive to permanent emigration and least sensitive to temporary emigration, and is of intermediate sensitivity to permanent or temporary immigration. This test is a versatile tool for testing the assumption of demographic closure in the analysis of capture-recapture data.

  1. Tumoricidal activity of low-energy 160-KV versus 6-MV X-rays against platinum-sensitized F98 glioma cells

    PubMed Central

    Lim, Sara N.; Pradhan, Anil K.; Barth, Rolf F.; Nahar, Sultana N.; Nakkula, Robin J.; Yang, Weilian; Palmer, Alycia M.; Turro, Claudia; Weldon, Michael; Bell, Erica Hlavin; Mo, Xiaokui

    2015-01-01

    The purposes of this study were (i) to investigate the differences in effects between 160-kV low-energy and 6-MV high-energy X-rays, both by computational analysis and in vitro studies; (ii) to determine the effects of each on platinum-sensitized F98 rat glioma and murine B16 melanoma cells; and (iii) to describe the in vitro cytotoxicity and in vivo toxicity of a Pt(II) terpyridine platinum (Typ-Pt) complex. Simulations were performed using the Monte Carlo code Geant4 to determine enhancement in absorption of low- versus high-energy X-rays by Pt and to determine dose enhancement factors (DEFs) for a Pt-sensitized tumor phantom. In vitro studies were carried out using Typ-Pt and again with carboplatin due to the unexpected in vivo toxicity of Typ-Pt. Cell survival was determined using clonogenic assays. In agreement with computations and simulations, in vitro data showed up to one log unit reduction in surviving fractions (SFs) of cells treated with 1–4 µg/ml of Typ-Pt and irradiated with 160-kV versus 6-MV X-rays. DEFs showed radiosensitization in the 50–200 keV range, which fell to approximate unity at higher energies, suggesting marginal interactions at MeV energies. Cells sensitized with 1–5 or 7 µg/ml of carboplatin and then irradiated also showed a significant decrease (P < 0.05) in SFs. However, it was unlikely this was due to increased interactions. Theoretical and in vitro studies presented here demonstrated that the tumoricidal activity of low-energy X-rays was greater than that of high-energy X-rays against Pt-sensitized tumor cells. Determining whether radiosensitization is a function of increased interactions will require additional studies. PMID:25266332

  2. PIXE analysis of caries related trace elements in tooth enamel

    NASA Astrophysics Data System (ADS)

    Annegarn, H. J.; Jodaikin, A.; Cleaton-Jones, P. E.; Sellschop, J. P. F.; Madiba, C. C. P.; Bibby, D.

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas susceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surfaces), with the aim of determining the possible roles of trace elements in the curious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and the capability of localised surface analysis compared with the pooled samples required for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  3. The effect of prolonged standing on touch sensitivity threshold of the foot: a pilot study.

    PubMed

    Wiggermann, Neal E; Werner, Robert A; Keyserling, W Monroe

    2012-02-01

    To determine the effect of prolonged standing on touch sensitivity of the foot. An observational study with replications. University laboratory. Ten healthy college students (5 men and 5 women), with a mean ± SD age of 23.5 ± 4.1 years and body mass of 67.4 ± 12.6 kg. Semmes-Weinstein monofilament tests were administered to 12 locations on the dorsal and plantar surfaces of the foot before and after 4 hours of standing. These locations were formed into several groupings (toes, metatarsal heads, midfoot, heel, all plantar sites, all dorsal sites), and paired t-tests were used to test for significant changes in sensitivity threshold after standing. The difference between sensitivity thresholds measured before and after standing for different locations on the foot. The average of all sensitivity thresholds on the plantar surface of the foot decreased (indicating increased sensitivity) from 0.56 to 0.36 g (P < .01) after 4 hours of prolonged standing. This change in threshold equated to a difference of 1 Semmes-Weinstein monofilament level. Changes in the sensitivity threshold of the dorsal aspect of the foot were not significant. Analysis of the results suggests that the plantar foot has greater sensitivity to touch after prolonged standing. These findings may be useful for identifying potential unintended bias in clinical touch sensitivity testing. Future research is necessary to understand the underlying mechanisms for this sensitivity change and to determine the onset and recovery times for sensitivity changes. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  4. Analyzing reflective narratives to assess the ethical reasoning of pediatric residents.

    PubMed

    Moon, Margaret; Taylor, Holly A; McDonald, Erin L; Hughes, Mark T; Beach, Mary Catherine; Carrese, Joseph A

    2013-01-01

    A limiting factor in ethics education in medical training has been difficulty in assessing competence in ethics. This study was conducted to test the concept that content analysis of pediatric residents' personal reflections about ethics experiences can identify changes in ethical sensitivity and reasoning over time. Analysis of written narratives focused on two of our ethics curriculum's goals: 1) To raise sensitivity to ethical issues in everyday clinical practice and 2) to enhance critical reflection on personal and professional values as they affect patient care. Content analysis of written reflections was guided by a tool developed to identify and assess the level of ethical reasoning in eight domains determined to be important aspects of ethical competence. Based on the assessment of narratives written at two times (12 to 16 months/apart) during their training, residents showed significant progress in two specific domains: use of professional values, and use of personal values. Residents did not show decline in ethical reasoning in any domain. This study demonstrates that content analysis of personal narratives may provide a useful method for assessment of developing ethical sensitivity and reasoning.

  5. Analysis of glycosaminoglycan-derived disaccharides by capillary electrophoresis using laser-induced fluorescence detection

    PubMed Central

    Chang, Yuqing; Yang, Bo; Zhao, Xue; Linhardt, Robert J.

    2012-01-01

    A quantitative and highly sensitive method for the analysis of glycosaminoglycan (GAG)-derived disaccharides is presented that relies on capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. This method enables complete separation of seventeen GAG-derived disaccharides in a single run. Unsaturated disaccharides were derivatized with 2-aminoacridone (AMAC) to improve sensitivity. The limit of detection was at the attomole level and about 100-fold more sensitive than traditional CE-ultraviolet detection. A CE separation timetable was developed to achieve complete resolution and shorten analysis time. The RSD of migration time and peak areas at both low and high concentrations of unsaturated disaccharides are all less than 2.7% and 3.2%, respectively, demonstrating that this is a reproducible method. This analysis was successfully applied to cultured Chinese hamster ovary cell samples for determination of GAG disaccharides. The current method simplifies GAG extraction steps, and reduces inaccuracy in calculating ratios of heparin/heparan sulfate to chondroitin sulfate/dermatan sulfate, resulting from the separate analyses of a single sample. PMID:22609076

  6. Theoretical considerations of some nonlinear aspects of hypersonic panel flutter

    NASA Technical Reports Server (NTRS)

    Mcintosh, S. C., Jr.

    1974-01-01

    A research project to analyze the effects of hypersonic nonlinear aerodynamic loading on panel flutter is reported. The test equipment and procedures for conducting the tests are explained. The effects of aerodynamic linearities on stability were evaluated by determining constant-initial-energy amplitude-sensitive stability boundaries and comparing them with the corresponding linear stability boundaries. An attempt to develop an alternative method of analysis for systems where amplitude-sensitive instability is possible is presented.

  7. High-resolution melting analysis for noninvasive prenatal diagnosis of IVS-II-I (G-A) fetal DNA in minor beta-thalassemia mothers.

    PubMed

    Zafari, Mandana; Gill, Pooria; Kowsaryan, Mehrnoush; Alipour, Abbass; Banihashemi, Ali

    2016-10-01

    The high-resolution melting (HRM) technique is fast, effective and successful method for mutation detection. The aim of this study was to determine the sensitivity and specificity of the HRM method for detection of a paternally inherited mutation in a fetus as a noninvasive prenatal diagnosis of β-thalassemia. Genomic DNAs were prepared from 50 β-thalassemia minor couples whose pregnancy was at risk for homozygous β-thalassemia. Ten milliliters of the maternal blood from each pregnant woman were collected and after separating plasma stored at -80 °C until analysis. The extracted DNAs were analyzed by HRM real-time PCR for detection of IVS-II-I (G-A) as a paternally inherited mutation. The gold standard was the result of a chorionic villus sampling by a standard reverse dot blotting test. The sensitivity and specificity of HRM real-time PCR were 92.6% and 82.6%, respectively. Also, the positive and negative predictive values were 86.2% and 90.47%, respectively. HRM real-time PCR was a sensitive and specific method for determining the paternally inherited mutation in the fetus at risk with thalassemia major.

  8. Determination of complex formation constants by phase sensitive alternating current polarography: Cadmium-polymethacrylic acid and cadmium-polygalacturonic acid.

    PubMed

    Garrigosa, Anna Maria; Gusmão, Rui; Ariño, Cristina; Díaz-Cruz, José Manuel; Esteban, Miquel

    2007-10-15

    The use of phase sensitive alternating current polarography (ACP) for the evaluation of complex formation constants of systems where electrodic adsorption is present has been proposed. The applicability of the technique implies the previous selection of the phase angle where contribution of capacitive current is minimized. This is made using Multivariate Curve Resolution by Alternating Least Squares (MCR-ALS) in the analysis of ACP measurements at different phase angles. The method is checked by the study of the complexation of Cd by polymethacrylic (PMA) and polygalacturonic (PGA) acids, and the optimal phase angles have been ca. -10 degrees for Cd-PMA and ca. -15 degrees for Cd-PGA systems. The goodness of phase sensitive ACP has been demonstrated comparing the determined complex formation constants with those obtained by reverse pulse polarography, a technique that minimizes the electrode adsorption effects on the measured currents.

  9. HPAEC-PAD for oligosaccharide analysis-novel insights into analyte sensitivity and response stability.

    PubMed

    Mechelke, Matthias; Herlet, Jonathan; Benz, J Philipp; Schwarz, Wolfgang H; Zverlov, Vladimir V; Liebl, Wolfgang; Kornberger, Petra

    2017-12-01

    The rising importance of accurately detecting oligosaccharides in biomass hydrolyzates or as ingredients in food, such as in beverages and infant milk products, demands for the availability of tools to sensitively analyze the broad range of available oligosaccharides. Over the last decades, HPAEC-PAD has been developed into one of the major technologies for this task and represents a popular alternative to state-of-the-art LC-MS oligosaccharide analysis. This work presents the first comprehensive study which gives an overview of the separation of 38 analytes as well as enzymatic hydrolyzates of six different polysaccharides focusing on oligosaccharides. The high sensitivity of the PAD comes at cost of its stability due to recession of the gold electrode. By an in-depth analysis of the sensitivity drop over time for 35 analytes, including xylo- (XOS), arabinoxylo- (AXOS), laminari- (LOS), manno- (MOS), glucomanno- (GMOS), and cellooligosaccharides (COS), we developed an analyte-specific one-phase decay model for this effect over time. Using this model resulted in significantly improved data normalization when using an internal standard. Our results thereby allow a quantification approach which takes the inevitable and analyte-specific PAD response drop into account. Graphical abstract HPAEC-PAD analysis of oligosaccharides and determination of PAD response drop leading to an improved data normalization.

  10. Preoperative localization strategies for primary hyperparathyroidism: an economic analysis.

    PubMed

    Lubitz, Carrie C; Stephen, Antonia E; Hodin, Richard A; Pandharipande, Pari

    2012-12-01

    Strategies for localizing parathyroid pathology preoperatively vary in cost and accuracy. Our purpose was to compute and compare comprehensive costs associated with common localization strategies. A decision-analytic model was developed to evaluate comprehensive, short-term costs of parathyroid localization strategies for patients with primary hyperparathyroidism. Eight strategies were compared. Probabilities of accurate localization were extracted from the literature, and costs associated with each strategy were based on 2011 Medicare reimbursement schedules. Differential cost considerations included outpatient versus inpatient surgeries, operative time, and costs of imaging. Sensitivity analyses were performed to determine effects of variability in key model parameters upon model results. Ultrasound (US) followed by 4D-CT was the least expensive strategy ($5,901), followed by US alone ($6,028), and 4D-CT alone ($6,110). Strategies including sestamibi (SM) were more expensive, with associated expenditures of up to $6,329 for contemporaneous US and SM. Four-gland, bilateral neck exploration (BNE) was the most expensive strategy ($6,824). Differences in cost were dependent upon differences in the sensitivity of each strategy for detecting single-gland disease, which determined the proportion of patients able to undergo outpatient minimally invasive parathyroidectomy. In sensitivity analysis, US alone was preferred over US followed by 4D-CT only when both the sensitivity of US alone for detecting an adenoma was ≥ 94 %, and the sensitivity of 4D-CT following negative US was ≤ 39 %. 4D-CT alone was the least costly strategy when US sensitivity was ≤ 31 %. Among commonly used strategies for preoperative localization of parathyroid pathology, US followed by selective 4D-CT is the least expensive.

  11. Longitudinal study of factors affecting taste sense decline in old-old individuals.

    PubMed

    Ogawa, T; Uota, M; Ikebe, K; Arai, Y; Kamide, K; Gondo, Y; Masui, Y; Ishizaki, T; Inomata, C; Takeshita, H; Mihara, Y; Hatta, K; Maeda, Y

    2017-01-01

    The sense of taste plays a pivotal role for personal assessment of the nutritional value, safety and quality of foods. Although it is commonly recognised that taste sensitivity decreases with age, alterations in that sensitivity over time in an old-old population have not been previously reported. Furthermore, no known studies utilised comprehensive variables regarding taste changes and related factors for assessments. Here, we report novel findings from a 3-year longitudinal study model aimed to elucidate taste sensitivity decline and its related factors in old-old individuals. We utilised 621 subjects aged 79-81 years who participated in the Septuagenarians, Octogenarians, Nonagenarians Investigation with Centenarians Study for baseline assessments performed in 2011 and 2012, and then conducted follow-up assessments 3 years later in 328 of those. Assessment of general health, an oral examination and determination of taste sensitivity were performed for each. We also evaluated cognitive function using Montreal Cognitive Assessment findings, then excluded from analysis those with a score lower than 20 in order to secure the validity and reliability of the subjects' answers. Contributing variables were selected using univariate analysis, then analysed with multivariate logistic regression analysis. We found that males showed significantly greater declines in taste sensitivity for sweet and sour tastes than females. Additionally, subjects with lower cognitive scores showed a significantly greater taste decrease for salty in multivariate analysis. In conclusion, our longitudinal study revealed that gender and cognitive status are major factors affecting taste sensitivity in geriatric individuals. © 2016 John Wiley & Sons Ltd.

  12. Determination of mutagenic amines in water and food samples by high pressure liquid chromatography with amperometric detection using a multiwall carbon nanotubes-glassy carbon electrode.

    PubMed

    Bueno, Ana María; Marín, Miguel Ángel; Contento, Ana María; Ríos, Ángel

    2016-02-01

    A chromatographic method, using amperometric detection, for the sensitive determination of six representative mutagenic amines was developed. A glassy carbon electrode (GCE), modified with multiwall carbon nanotubes (GCE-CNTs), was prepared and its response compared to a conventional glassy carbon electrode. The chromatographic method (HPLC-GCE-CNTs) allowed the separation and the determination of heterocyclic aromatic amines (HAAs) classified as mutagenic amines by the International Agency for Research of Cancer. The new electrode was systematically studied in terms of stability, sensitivity, and reproducibility. Statistical analysis of the obtained data demonstrated that the modified electrode provided better sensitivity than the conventional unmodified ones. Detection limits were in the 3.0 and 7.5 ng/mL range, whereas quantification limits ranged between 9.5 and 25.0 ng/mL were obtained. The applicability of the method was demonstrated by the determination of the amines in several types of samples (water and food samples). Recoveries indicate very good agreement between amounts added and those found for all HAAs (recoveries in the 92% and 105% range). Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Determination of uranium and thorium in materials associated with real time electronic solar neutrino detectors

    NASA Astrophysics Data System (ADS)

    Fassett, J. D.; Kelly, W. R.

    1992-07-01

    The application of isotope dilution thermal ionization mass spectrometry to the determination of both uranium and thorium in four different target materials used or proposed for electronic neutrino detectors is described. Isotope dilution analysis is done using highly enriched 233U and 230Th separated isotopes. Sensitivity of the technique is such that sub-picogram amounts of material are readily measured. The overall limit to measurement is caused by contamination of these elements during the measurement process. Uranium is more easily measured than thorium because both the instrumental sensitivity is higher and contamination is better controlled. The materials analyzed were light and heavy water, pseudocumene, and mineral oil.

  14. Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

    NASA Technical Reports Server (NTRS)

    Otterson, D. A.

    1977-01-01

    The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

  15. Pain sensitivity mediates the relationship between stress and headache intensity in chronic tension-type headache.

    PubMed

    Cathcart, Stuart; Bhullar, Navjot; Immink, Maarten; Della Vedova, Chris; Hayball, John

    2012-01-01

    A central model for chronic tension-type headache (CTH) posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. The prediction from this model that pain sensitivity mediates the relationship between stress and headache activity has not yet been examined. To determine whether pain sensitivity mediates the relationship between stress and prospective headache activity in CTH sufferers. Self-reported stress, pain sensitivity and prospective headache activity were measured in 53 CTH sufferers recruited from the general population. Pain sensitivity was modelled as a mediator between stress and headache activity, and tested using a nonparametric bootstrap analysis. Pain sensitivity significantly mediated the relationship between stress and headache intensity. The results of the present study support the central model for CTH, which posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. Implications for the mechanisms and treatment of CTH are discussed.

  16. Analysis of the temperature sensitivity of Japanese rubella vaccine strain TO-336.vac and its effect on immunogenicity in the guinea pig.

    PubMed

    Okamoto, Kiyoko; Ami, Yasushi; Suzaki, Yuriko; Otsuki, Noriyuki; Sakata, Masafumi; Takeda, Makoto; Mori, Yoshio

    2016-04-01

    The marker of Japanese domestic rubella vaccines is their lack of immunogenicity in guinea pigs. This has long been thought to be related to the temperature sensitivity of the viruses, but supporting evidence has not been described. In this study, we generated infectious clones of TO-336.vac, a Japanese domestic vaccine, TO-336.GMK5, the parental virus of TO-336.vac, and their mutants, and determined the molecular bases of their temperature sensitivity and immunogenicity in guinea pigs. The results revealed that Ser(1159) in the non-structural protein-coding region was responsible for the temperature sensitivity of TO-336.vac dominantly, while the structural protein-coding region affected the temperature sensitivity subordinately. The findings further suggested that the temperature sensitivity of TO-336.vac affected the antibody induction in guinea pigs after subcutaneous inoculation. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Predicting Risk Sensitivity in Humans and Lower Animals: Risk as Variance or Coefficient of Variation

    ERIC Educational Resources Information Center

    Weber, Elke U.; Shafir, Sharoni; Blais, Ann-Renee

    2004-01-01

    This article examines the statistical determinants of risk preference. In a meta-analysis of animal risk preference (foraging birds and insects), the coefficient of variation (CV), a measure of risk per unit of return, predicts choices far better than outcome variance, the risk measure of normative models. In a meta-analysis of human risk…

  18. Spectrophotometric determination of sulphate in automotive fuel ethanol by sequential injection analysis using dimethylsulphonazo(III) reaction.

    PubMed

    de Oliveira, Fabio Santos; Korn, Mauro

    2006-01-15

    A sensitive SIA method was developed for sulphate determination in automotive fuel ethanol. This method was based on the reaction of sulphate with barium-dimethylsulphonazo(III) leading to a decrease on the magnitude of analytical signal monitored at 665 nm. Alcohol fuel samples were previously burned up to avoid matrix effects for sulphate determinations. Binary sampling and stop-flow strategies were used to increase the sensitivity of the method. The optimization of analytical parameter was performed by response surface method using Box-Behnker and central composite designs. The proposed sequential flow procedure permits to determine up to 10.0mg SO(4)(2-)l(-1) with R.S.D. <2.5% and limit of detection of 0.27 mg l(-1). The method has been successfully applied for sulphate determination in automotive fuel alcohol and the results agreed with the reference volumetric method. In the optimized condition the SIA system carried out 27 samples per hour.

  19. Peptide biomarkers as a way to determine meat authenticity.

    PubMed

    Sentandreu, Miguel Angel; Sentandreu, Enrique

    2011-11-01

    Meat fraud implies many illegal procedures affecting the composition of meat and meat products, something that is commonly done with the aim to increase profit. These practices need to be controlled by legal authorities by means of robust, accurate and sensitive methodologies capable to assure that fraudulent or accidental mislabelling does not arise. Common strategies traditionally used to assess meat authenticity have been based on methods such as chemometric analysis of a large set of data analysis, immunoassays or DNA analysis. The identification of peptide biomarkers specific of a particular meat species, tissue or ingredient by proteomic technologies constitutes an interesting and promising alternative to existing methodologies due to its high discriminating power, robustness and sensitivity. The possibility to develop standardized protein extraction protocols, together with the considerably higher resistance of peptide sequences to food processing as compared to DNA sequences, would overcome some of the limitations currently existing for quantitative determinations of highly processed food samples. The use of routine mass spectrometry equipment would make the technology suitable for control laboratories. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. A chemometric strategy for optimization of solid-phase microextraction: determination of bisphenol A and 4-nonylphenol with HPLC.

    PubMed

    Liu, Xiaoyan; Zhang, Xiaoyun; Zhang, Haixia; Liu, Mancang

    2008-08-01

    A sensitive method for the analysis of bisphenol A and 4-nonylphenol is developed by means of the optimization of solid-phase microextraction using Uniform Experimental Design methodology followed by high-performance liquid chromatographic analysis with fluorescence detection. The optimal extraction conditions are determined based on the relationship between parameters and the peak area. The curve calibration plots are linear (r2>or=0.9980) over the concentration range of 1.25-125 ng/mL for bisphenol A and 2.59-202.96 ng/mL for 4-nonylphenol, respectively. The detection limits, based on a signal-to-noise ratio of 3, are 0.097 ng/mL for bisphenol A and 0.27 ng/mL for 4-nonylphenol, respectively. The validity of the proposed method is demonstrated by the analysis of the investigated analytes in real water samples and sensitivity of the optimized method is verified by comparing results with those obtained by previous methods using the same commercial solid-phase microextraction fiber.

  1. Geotechnical properties of ash deposits near Hilo, Hawaii

    USGS Publications Warehouse

    Wieczorek, G.F.; Jibson, R.W.; Wilson, R.C.; Buchanan-Banks, J. M.

    1982-01-01

    Two holes were hand augered and sampled in ash deposits near Hilo, Hawaii. Color, water content and sensitivity of the ash were measured in the field. The ash alternated between reddish brown and dark reddish brown in color and had water contents as high as 392%. A downhole vane shear device measured sensitivities as high as 6.9. A series of laboratory tests including grain size distribution, Atterberg limits, X-ray diffraction analysis, total carbon determination, vane shear, direct shear and triaxial tests were performed to determine the composition and geotechnical properties of the ash. The ash is very fine grained, highly plastic and composed mostly of gibbsite and amorphous material presumably allophane. The ash has a high angle of internal friction ranging from 40-43? and is classified as medium to very sensitive. A series of different ash layers was distinguished on the basis of plasticity and other geotechnical properties. Sensitivity may be due to a metastable fabric, cementation, leaching, high organic content, and thixotropy. The sensitivity of the volcanic ash deposits near Hilo is consistent with documented slope instability during earthquakes in Hawaii. The high angles of internal friction and cementation permit very steep slopes under static conditions. However, because of high sensitivity of the ash, these slopes are particularly susceptible to seismically-induced landsliding.

  2. Cost Analysis of Fluconazole Prophylaxis for Prevention of Neonatal Invasive Candidiasis.

    PubMed

    Swanson, Jonathan R; Vergales, Jeff; Kaufman, David A; Sinkin, Robert A

    2016-05-01

    Fluconazole prophylaxis (FP) in premature infants is well studied and has been shown to decrease invasive candidiasis (ICs). IC in neonates has significant financial costs; determining the cost-benefit of FP may provide additional justification for targeting high-risk neonates. We aimed to determine the IC rate in premature infants at which FP is cost-beneficial. A decision tree cost-analysis model using cost of FP related to costs associated with IC was used. We searched PubMed for all papers that used intravenous FP and reported rates of IC in very low birth weight neonates. Average IC rates in those who received FP (2.0%; range, 0-6.1%) and in those who did not receive FP (9.2%; range, 0-20.5%) were used. Incremental hospital costs because of IC and for FP were retrieved from the literature. Sensitivity analysis was performed to determine the incremental cost of FP across the range of published IC rates. The average cost per patient attributed to IC in patients receiving FP was $785 versus $2617 in those not receiving FP. Sensitivity analysis demonstrates the rate of IC would need to be <2.8% for FP to lose its cost-benefit. In Monte Carlo simulation, targeting infants <1000 g would lead to $50,304,333 in cost savings per year in the United States. FP provides a cost-advantage across most IC rates seen in the youngest premature infants. Using a rate of 2.8% for their individual high-risk neonatal intensive care unit patients, providers can determine if FP is cost-beneficial in determining for whom to provide IC prophylaxis.

  3. Blinded study determination of high sensitivity and specificity microchip electrophoresis-SSCP/HA to detect mutations in the p53 gene.

    PubMed

    Hestekin, Christa N; Lin, Jennifer S; Senderowicz, Lionel; Jakupciak, John P; O'Connell, Catherine; Rademaker, Alfred; Barron, Annelise E

    2011-11-01

    Knowledge of the genetic changes that lead to disease has grown and continues to grow at a rapid pace. However, there is a need for clinical devices that can be used routinely to translate this knowledge into the treatment of patients. Use in a clinical setting requires high sensitivity and specificity (>97%) in order to prevent misdiagnoses. Single-strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are two DNA-based, complementary methods for mutation detection that are inexpensive and relatively easy to implement. However, both methods are most commonly detected by slab gel electrophoresis, which can be labor-intensive, time-consuming, and often the methods are unable to produce high sensitivity and specificity without the use of multiple analysis conditions. Here, we demonstrate the first blinded study using microchip electrophoresis (ME)-SSCP/HA. We demonstrate the ability of ME-SSCP/HA to detect with 98% sensitivity and specificity >100 samples from the p53 gene exons 5-9 in a blinded study in an analysis time of <10 min. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Characterization and genetic mapping of a Photoperiod-sensitive dwarf 1 locus in rice (Oryza sativa L.).

    PubMed

    Li, Riqing; Xia, Jixing; Xu, Yiwei; Zhao, Xiucai; Liu, Yao-Guang; Chen, Yuanling

    2014-01-01

    Plant height is an important agronomic trait for crop architecture and yield. Most known factors determining plant height function in gibberellin or brassinosteroid biosynthesis or signal transduction. Here, we report a japonica rice (Oryza sativa ssp. japonica) dominant dwarf mutant, Photoperiod-sensitive dwarf 1 (Psd1). The Psd1 mutant showed impaired cell division and elongation, and a severe dwarf phenotype under long-day conditions, but nearly normal growth in short-day. The plant height of Psd1 mutant could not be rescued by gibberellin or brassinosteroid treatment. Genetic analysis with R1 and F2 populations determined that Psd1 phenotype was controlled by a single dominant locus. Linkage analysis with 101 tall F2 plants grown in a long-day season, which were derived from a cross between Psd1 and an indica cultivar, located Psd1 locus on chromosome 1. Further fine-mapping with 1017 tall F2 plants determined this locus on an 11.5-kb region. Sequencing analysis of this region detected a mutation site in a gene encoding a putative lipid transfer protein; the mutation produces a truncated C-terminus of the protein. This study establishes the genetic foundation for understanding the molecular mechanisms regulating plant cell division and elongation mediated by interaction between genetic and environmental factors.

  5. On determining important aspects of mathematical models: Application to problems in physics and chemistry

    NASA Technical Reports Server (NTRS)

    Rabitz, Herschel

    1987-01-01

    The use of parametric and functional gradient sensitivity analysis techniques is considered for models described by partial differential equations. By interchanging appropriate dependent and independent variables, questions of inverse sensitivity may be addressed to gain insight into the inversion of observational data for parameter and function identification in mathematical models. It may be argued that the presence of a subset of dominantly strong coupled dependent variables will result in the overall system sensitivity behavior collapsing into a simple set of scaling and self similarity relations amongst elements of the entire matrix of sensitivity coefficients. These general tools are generic in nature, but herein their application to problems arising in selected areas of physics and chemistry is presented.

  6. Determination of sex origin of meat and meat products on the DNA basis: a review.

    PubMed

    Gokulakrishnan, Palanisamy; Kumar, Rajiv Ranjan; Sharma, Brahm Deo; Mendiratta, Sanjod Kumar; Malav, Omprakash; Sharma, Deepak

    2015-01-01

    Sex determination of domestic animal's meat is of potential value in meat authentication and quality control studies. Methods aiming at determining the sex origin of meat may be based either on the analysis of hormone or on the analysis of nucleic acids. At the present time, sex determination of meat and meat products based on hormone analysis employ gas chromatography-mass spectrometry (GC-MS), high-performance liquid chromatography-mass spectrometry/mass spectrometry (HPLC-MS/MS), and enzyme-linked immunosorbent assay (ELISA). Most of the hormone-based methods proved to be highly specific and sensitive but were not performed on a regular basis for meat sexing due to the technical limitations or the expensive equipments required. On the other hand, the most common methodology to determine the sex of meat is unquestionably traditional polymerase chain reaction (PCR) that involves gel electrophoresis of DNA amplicons. This review is intended to provide an overview of the DNA-based methods for sex determination of meat and meat products.

  7. Approach To Development of Guidelines For Determination of Natural Attenuation Capacity and Resilience of Soils

    NASA Astrophysics Data System (ADS)

    Putters, B.

    The natural attenuation capacity of the soil is often used to help remove contaminants from the soil and groundwater. However, the definition of natural attenuation capac- ity in terms of soil properties, and how it should be measured are still a matter of discussion. Moreover, due to the interaction between soil and pollutant during the attenuation processes, changes in soil properties may occur. The resilience of the soil determines the rate of recovery of the soil, and to what extent it regains its original capacity for attenuation. This resilience, too, is not yet defined or measureable. The objective of the research is to develop guidelines to determine the natural attenu- ation capacity and the resilience of soils. The approach comprises five steps: 1. Experimental data on degradation and adsorp- tion are collected from literature. Missing data are filled by means of regression tech- niques. 2. Based upon existing knowledge on fate and behaviour of pollutants in soil environment, data are analysed on expected relations between soil parameters: which parameters determine the processes. 3. The most important parameters are analysed in a sensitivity analysis, performed by means of a mechanistic model. The testing vari- ables in the sensitivity analysis are an expression of the natural attenuation capacity and the resilience, respectively, and will be related to time. 4. The sensitivity analy- sis is extended by development of an artificial neural network and by use of genetic algorithms. 5. Data from the realisations (model calculations with different input) are classified into guidelines.

  8. Detection of common carotid artery stenosis using duplex ultrasonography: a validation study with computed tomographic angiography.

    PubMed

    Slovut, David P; Romero, Javier M; Hannon, Kathleen M; Dick, James; Jaff, Michael R

    2010-01-01

    Severe stenosis of the common carotid artery (CCA), while uncommon, is associated with increased risk of transient ischemic attack and stroke. To date, no validated duplex ultrasound criteria have been established for grading the severity of CCA stenosis. The goal of this study was to use receiver-operating curve (ROC) analysis with computed tomographic angiography as the reference standard to establish duplex ultrasound criteria for diagnosing >or=50% CCA stenosis. The study cohort included 64 patients (42 men, 22 women) with a mean age of 65 +/- 12 years (range, 16-89 years) who had CCA peak systolic velocity (PSV) >or=150 cm/sec and underwent computed tomographic angiography (CTA) of the cervical and intracerebral vessels within 1 month of the duplex examination. One study was excluded because the CTA was technically inadequate, whereas another was excluded because the patient underwent bilateral CCA stenting. The CCA ipsilateral to any of the following was excluded from the analysis: innominate artery occlusion (n = 1), previous stenting of the ICA or CCA (n = 7), carotid endarterectomy (n = 1), or carotid-to-carotid bypass (n = 1). Thus, the data set included 62 patients and 115 vessels. Bland-Altman analysis was used to examine the agreement between two measures of luminal reduction measured by CTA: percent diameter stenosis and percent area stenosis. Receiver operating characteristic (ROC) analysis was used to determine optimal PSV and EDV thresholds for diagnosing >or=50% CCA stenosis. Severity of CCA stenosis was <50% in 76 vessels, 50%-59% in eight, 60%-69% in eight, 70%-79% in nine, 80%-89% in three, 90%-99% in five, and occluded in six. Duplex ultrasonography identified six of six (100%) patients with 100% CCA occlusion by CTA. Bland-Altman analysis showed poor agreement between percent stenosis determined by vessel diameter compared with percent stenosis determined by reduction in lumen area. Therefore, subsequent analysis was performed using percent stenosis by area. ROC analysis of different PSV thresholds for detecting stenosis >or=50% showed that >182 cm/sec was the most accurate with a sensitivity of 64% and specificity of 88% (P < .0001). Sensitivity, specificity, and accuracy of carotid duplex were higher when the stenosis was located in the mid or distal aspects of the CCA (sensitivity 76%, specificity 89%, area under curve 0.84, P < .001) than in the intrathoracic and proximal segment of the artery (P = NS). ROC analysis of different EDV thresholds for detecting CCA stenosis >or=50% showed that >30 cm/sec was the most accurate with a sensitivity of 54% and a specificity of 74% (P < .0239). Duplex ultrasonography is highly sensitive, specific, and accurate for detecting CCA lesions in the mid and distal CCA. Use of peak systolic velocity may lead to improved detection of CCA disease and initiation of appropriate therapy to reduce the risk of stroke. Copyright 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  9. The Sensitivity of the Incidence of Poverty to Different Measures of Income: School-Aged Children and Families. The Measure of Poverty, Technical Paper XVII.

    ERIC Educational Resources Information Center

    Coe, Richard D.; And Others

    This study is a two-part analysis aimed at determining what differences occur in the incidence of poverty when different definitions of income are employed and when the time frame of analysis is changed. The first part of the analysis concentrates on school-aged children, while the second part studies families. The study is based on data from the…

  10. Process modelling for Space Station experiments

    NASA Technical Reports Server (NTRS)

    Alexander, J. Iwan D.; Rosenberger, Franz; Nadarajah, Arunan; Ouazzani, Jalil; Amiroudine, Sakir

    1990-01-01

    Examined here is the sensitivity of a variety of space experiments to residual accelerations. In all the cases discussed the sensitivity is related to the dynamic response of a fluid. In some cases the sensitivity can be defined by the magnitude of the response of the velocity field. This response may involve motion of the fluid associated with internal density gradients, or the motion of a free liquid surface. For fluids with internal density gradients, the type of acceleration to which the experiment is sensitive will depend on whether buoyancy driven convection must be small in comparison to other types of fluid motion, or fluid motion must be suppressed or eliminated. In the latter case, the experiments are sensitive to steady and low frequency accelerations. For experiments such as the directional solidification of melts with two or more components, determination of the velocity response alone is insufficient to assess the sensitivity. The effect of the velocity on the composition and temperature field must be considered, particularly in the vicinity of the melt-crystal interface. As far as the response to transient disturbances is concerned, the sensitivity is determined by both the magnitude and frequency of the acceleration and the characteristic momentum and solute diffusion times. The microgravity environment, a numerical analysis of low gravity tolerance of the Bridgman-Stockbarger technique, and modeling crystal growth by physical vapor transport in closed ampoules are discussed.

  11. Comparison of methods for determination of volatile organic compounds in drinking water.

    PubMed

    Golfinopoulos, S K; Lekkas, T D; Nikolaou, A D

    2001-10-01

    Comparison of four methods including liquid-liquid extraction (LLE), direct aqueous injection (DAI), purge and trap (PAT) and head space (HS) were carried out in this work for determination of volatile organic compounds (VOCs) including trihalomethanes (THMs) in drinking water. This comparison is made especially to show the advantages and disadvantages and specifically the different detection limits (DL) that can be obtained for a given type of analysis. LLE is applicable only for determination of the THMs concentrations, while DAI, PAT, HS methods with different DL each of them are applicable for all VOCs, with PAT to be the most sensitive. Sampling apparatus and procedure for all these methods except of PAT are very simple and easy, but possible disadvantages for LLE and DAI are the low sensitivity and especially the detection only of THMs with LLE.

  12. Highly selective and sensitive determination of Cu2+ in drink and water samples based on a 1,8-diaminonaphthalene derived fluorescent sensor

    NASA Astrophysics Data System (ADS)

    Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan

    2018-04-01

    A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.

  13. How often do sensitivity analyses for economic parameters change cost-utility analysis conclusions?

    PubMed

    Schackman, Bruce R; Gold, Heather Taffet; Stone, Patricia W; Neumann, Peter J

    2004-01-01

    There is limited evidence about the extent to which sensitivity analysis has been used in the cost-effectiveness literature. Sensitivity analyses for health-related QOL (HR-QOL), cost and discount rate economic parameters are of particular interest because they measure the effects of methodological and estimation uncertainties. To investigate the use of sensitivity analyses in the pharmaceutical cost-utility literature in order to test whether a change in economic parameters could result in a different conclusion regarding the cost effectiveness of the intervention analysed. Cost-utility analyses of pharmaceuticals identified in a prior comprehensive audit (70 articles) were reviewed and further audited. For each base case for which sensitivity analyses were reported (n = 122), up to two sensitivity analyses for HR-QOL (n = 133), cost (n = 99), and discount rate (n = 128) were examined. Article mentions of thresholds for acceptable cost-utility ratios were recorded (total 36). Cost-utility ratios were denominated in US dollars for the year reported in each of the original articles in order to determine whether a different conclusion would have been indicated at the time the article was published. Quality ratings from the original audit for articles where sensitivity analysis results crossed the cost-utility ratio threshold above the base-case result were compared with those that did not. The most frequently mentioned cost-utility thresholds were $US20,000/QALY, $US50,000/QALY, and $US100,000/QALY. The proportions of sensitivity analyses reporting quantitative results that crossed the threshold above the base-case results (or where the sensitivity analysis result was dominated) were 31% for HR-QOL sensitivity analyses, 20% for cost-sensitivity analyses, and 15% for discount-rate sensitivity analyses. Almost half of the discount-rate sensitivity analyses did not report quantitative results. Articles that reported sensitivity analyses where results crossed the cost-utility threshold above the base-case results (n = 25) were of somewhat higher quality, and were more likely to justify their sensitivity analysis parameters, than those that did not (n = 45), but the overall quality rating was only moderate. Sensitivity analyses for economic parameters are widely reported and often identify whether choosing different assumptions leads to a different conclusion regarding cost effectiveness. Changes in HR-QOL and cost parameters should be used to test alternative guideline recommendations when there is uncertainty regarding these parameters. Changes in discount rates less frequently produce results that would change the conclusion about cost effectiveness. Improving the overall quality of published studies and describing the justifications for parameter ranges would allow more meaningful conclusions to be drawn from sensitivity analyses.

  14. Sensitive determination of enoxacin in pharmaceutical formulations by its quench effect on the fluorescence of glutathione-capped CdTe quantum dots.

    PubMed

    Yang, Qiong; Tan, Xuanping; Yang, Jidong

    2016-02-01

    A sensitive and simple method for the determination of enoxacin (ENX) was developed based on the fluorescence quenching effect of ENX for glutathione (GSH)-capped CdTe quantum dots (QDs). Under optimum conditions, a good linear relationship was obtained from 4.333 × 10(-9)  mol⋅L(-1) to 1.4 × 10(-5)  mol⋅L(-1) with a correlation coefficient (R) of 0.9987, and the detection limit (3σ/K) was 1.313 × 10(-9)  mol⋅L(-1). The corresponding mechanism has been proposed on the basis of electron transfer supported by ultraviolet-visible (UV) light absorption, fluorescence spectroscopy, and the measurement of fluorescence lifetime. The method has been applied to the determination of ENX in pharmaceutical formulations (enoxacin gluconate injections and commercial tablets) with satisfactory results. The proposed method manifested several advantages such as high sensitivity, short analysis time, low cost and ease of operation. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Hydrographic charting from Landsat satellite - A comparison with aircraft imagery

    NASA Technical Reports Server (NTRS)

    Middleton, E. M.; Barker, J. L.

    1976-01-01

    The relative capabilities of two remote-sensing systems in measuring depth and, consequently, bottom contours in sandy-bottomed and sediment-laden coastal waters were determined quantitatively. The Multispectral Scanner (MSS), orbited on the Landsat-2 satellite, and the Ocean Color Scanner (OCS), flown on U-2 aircraft, were used for this evaluation. Analysis of imagery taken simultaneously indicates a potential for hydrographic charting of marine coastal and shallow shelf areas, even when water turbidity is a factor. Several of the eight optical channels examined on the OCS were found to be sensitive to depth or depth-related information. The greatest sensitivity was in OCS-4 (0.544 plus or minus 0.012 micron) from which contours corresponding to depths up to 12 m were determined. The sharpness of these contours and their spatial stability through time suggests that upwelling radiance is a measure of bottom reflectance and not of water turbidity. The two visible channels on Landsat's MSS were less sensitive in the discrimination of contours, with depths up to 8 m in the high-gain mode (3 X) determined in MSS-4 (0.5 to 0.6 micron).

  16. Hydrographic charting from LANDSAT Satellite: A comparison with aircraft imagery

    NASA Technical Reports Server (NTRS)

    Middleton, E. M.; Barker, J. L.

    1976-01-01

    The relative capabilities of two remote-sensing systems in measuring depth and, consequently, bottom contours in sandy-bottomed and sediment-laden coastal waters were determined quantitatively. The multispectral scanner (MSS), orbited on the LANDSAT-2 Satellite, and the ocean color scanner (OCS), flown on U-2 aircraft, were used. Analysis of imagery taken simultaneously indicates a potential for hydrographic charting of marine coastal and shallow shelf areas, even when water turbidity is a factor. Several of the eight optical channels examined on the OCS were found to be sensitive to depth or depth-related information. The greatest sensitivity was in OCS-4(0.544 + or - 0.012 microns) from which contours corresponding to depths up to 12m were determined. The sharpness of these contours and their spatial stability through time suggests that upwelling radiance is a measure of bottom reflectance and not of water turbidity. The two visible channels on LANDSAT's MSS were less sensitive in the discrimination of contours, with depths up to 8m in the high-gain mode (3x) determined in MSS-4(0.5 to 0.6 microns).

  17. Rapid analysis of N-linked oligosaccharides in glycoproteins (ovalbumin, ribonuclease B and fetuin) by reversed-phase ultra-performance liquid chromatography with fluorescence detection and electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Kurihara, Takamasa; Min, Jun Zhe; Hirata, Asuka; Toyo'oka, Toshimasa; Inagaki, Shinsuke

    2009-05-01

    Rapid, selective and sensitive determination of N-linked oligosaccharides in glycoproteins (ovalbumin, ribonuclease B and fetuin) was performed by ultra-performance liquid chromatography (UPLC) with fluorescence (FL) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS). The asparaginyl-oligosaccharide moiety was first liberated from each glycoprotein by pronase E (a proteolitic enzyme). The oligosaccharide fractions separated by gel-permeation chromatography were labeled with 1-pyrenesulfonyl chloride (PSC, a fluorescence reagent), separated by UPLC in a short run time, and then detected by FL and TOF-MS. The PSC-labeled oligosaccharides were selectively identified from the FL detection and then sensitively determined by ESI-TOF-MS. As the results, 15, eight and four kinds of N-linked oligosaccharides were detected from ovalbumin, ribonuclease B and fetuin, respectively. Because the present method is rapid (within 9 min), selective and sensitive (approximate 60 fmol, S/N = 5), the determination of N-linked oligosaccharides in various glycoproteins seems to be possible.

  18. Simultaneous determination of flubendiamide its metabolite desiodo flubendiamide residues in cabbage, tomato and pigeon pea by HPLC.

    PubMed

    Paramasivam, M; Banerjee, Hemanta

    2011-10-01

    A sensitive and simple method for simultaneous analysis of flubendiamide and its metabolite desiodo flubendiamide in cabbage, tomato and pigeon pea has been developed. The residues were extracted with QuEChERS method followed by dispersive solid-phase extraction with primary secondary amine sorbent to remove co extractives, prior to analysis by HPLC coupled with UV-Vis detector. The recoveries of flubendiamide and desiodo flubendiamide were ranged from 85.1 to 98.5% and 85.9 to 97.1% respectively with relative standard deviations (RSD) less than 5% and sensitivity of 0.01 μg g(-1). The method offers a less expensive and safer alternative to the existing residue analysis methods for vegetables. © Springer Science+Business Media, LLC 2011

  19. Sensitivity to friction for primary explosives.

    PubMed

    Matyáš, Robert; Šelešovský, Jakub; Musil, Tomáš

    2012-04-30

    The sensitivity to friction for a selection of primary explosives has been studied using a small BAM friction apparatus. The probit analysis was used for the construction of a sensitivity curve for each primary explosive tested. Two groups of primary explosives were chosen for measurement (a) the most commonly used industrially produced primary explosives (e.g. lead azide, tetrazene, dinol, lead styphnate) and (b) the most produced improvised primary explosives (e.g. triacetone triperoxide, hexamethylenetriperoxide diamine, mercury fulminate, acetylides of heavy metals). A knowledge of friction sensitivity is very important for determining manipulation safety for primary explosives. All the primary explosives tested were carefully characterised (synthesis procedure, shape and size of crystals). The sensitivity curves obtained represent a unique set of data, which cannot be found anywhere else in the available literature. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Probabilistic structural analysis of a truss typical for space station

    NASA Technical Reports Server (NTRS)

    Pai, Shantaram S.

    1990-01-01

    A three-bay, space, cantilever truss is probabilistically evaluated using the computer code NESSUS (Numerical Evaluation of Stochastic Structures Under Stress) to identify and quantify the uncertainties and respective sensitivities associated with corresponding uncertainties in the primitive variables (structural, material, and loads parameters) that defines the truss. The distribution of each of these primitive variables is described in terms of one of several available distributions such as the Weibull, exponential, normal, log-normal, etc. The cumulative distribution function (CDF's) for the response functions considered and sensitivities associated with the primitive variables for given response are investigated. These sensitivities help in determining the dominating primitive variables for that response.

  1. Hepcidin as a possible marker in determination of malignancy degree and sensitivity of breast cancer cells to cytostatic drugs.

    PubMed

    Yalovenko, T M; Todor, I M; Lukianova, N Y; Chekhun, V F

    2016-06-01

    To investigate the role of hepcidin (Hepc) in the formation of cells malignant phenotype in vitro and its expression in the dyna-mics of growth of Walker-256 carcinosarcoma with different sensitivity to doxorubicin (Dox). The cell lines used in the analysis included T47D, MCF-7, MDA-MB-231, MDA-MB-468, MCF/CP, and MCF/Dox. Hepc expression was studied by immunocytochemical method. "Free" iron content was determined by EPR spectroscopy. Determination of Hepc expression in homogenates of tumor tissue and in blood serum of rats with Dox-sensitive and -resistant Walker-256 carcinosarcoma was performed. It was found that Hepc levels in breast cancer (BC) cells with high degree of malignancy (MDA-MB-231, MDA-MB-468) and drug-resistant phenotype (MCF/CP, MCF/Dox) were by 1.5-2 times higher (p < 0.05) in comparison with sensitive and less malignant BC cells. The development of drug-resistant phenotype in Walker-256 carcinosarcoma cells was accompanied by increasing of Hepc and "free" iron content (by 2.4 and 1.2 times, respectively). The data of in vitro and in vivo research evidenced on involvement of Hepc in formation of BC cells malignant phenotype and their resistance to Dox.

  2. Influence of Neuroblastoma Stage on Serum-Based Detection of MYCN Amplification

    PubMed Central

    Combaret, Valerie; Hogarty, Michael D; London, Wendy B; McGrady, Patrick; Iacono, Isabelle; Brejon, Stephanie; Swerts, Katrien; Noguera, Rosa; Gross, Nicole; Rousseau, Raphael; Puisieux, Alain

    2010-01-01

    Background MYCN oncogene amplification has been defined as the most important prognostic factor for neuroblastoma, the most common solid extracranial neoplasm in children. High copy numbers are strongly associated with rapid tumor progression and poor outcome, independently of tumor stage or patient age, and this has become an important factor in treatment stratification. Procedure By Real Time Quantitative PCR analysis, we evaluated the clinical relevance of circulating MYCN DNA of 267 patients with locoregional or metastatic neuroblastoma in children less than 18 months of age. Results For patients in this age group with INSS stage 4 or 4S NB and stage 3 patients, serum-based determination of MYCN DNA sequences had good sensitivity (85%, 83% and 75% respectively) and high specificity (100%) when compared to direct tumor gene determination. In contrast, the approach showed low sensitivity patients with stage 1 and 2 disease. Conclusion Our results show that the sensitivity of the serum-based MYCN DNA sequence determination depends on the stage of the disease. However, this simple, reproducible assay may represent a reasonably sensitive and very specific tool to assess tumor MYCN status in cases with stage 3 and metastatic disease for whom a wait and see strategy is often recommended. PMID:19301388

  3. Are quantitative sensitivity analysis methods always reliable?

    NASA Astrophysics Data System (ADS)

    Huang, X.

    2016-12-01

    Physical parameterizations developed to represent subgrid-scale physical processes include various uncertain parameters, leading to large uncertainties in today's Earth System Models (ESMs). Sensitivity Analysis (SA) is an efficient approach to quantitatively determine how the uncertainty of the evaluation metric can be apportioned to each parameter. Also, SA can identify the most influential parameters, as a result to reduce the high dimensional parametric space. In previous studies, some SA-based approaches, such as Sobol' and Fourier amplitude sensitivity testing (FAST), divide the parameters into sensitive and insensitive groups respectively. The first one is reserved but the other is eliminated for certain scientific study. However, these approaches ignore the disappearance of the interactive effects between the reserved parameters and the eliminated ones, which are also part of the total sensitive indices. Therefore, the wrong sensitive parameters might be identified by these traditional SA approaches and tools. In this study, we propose a dynamic global sensitivity analysis method (DGSAM), which iteratively removes the least important parameter until there are only two parameters left. We use the CLM-CASA, a global terrestrial model, as an example to verify our findings with different sample sizes ranging from 7000 to 280000. The result shows DGSAM has abilities to identify more influential parameters, which is confirmed by parameter calibration experiments using four popular optimization methods. For example, optimization using Top3 parameters filtered by DGSAM could achieve substantial improvement against Sobol' by 10%. Furthermore, the current computational cost for calibration has been reduced to 1/6 of the original one. In future, it is necessary to explore alternative SA methods emphasizing parameter interactions.

  4. SEQUENTIAL RADIOCHEMICAL ANALYSIS FOR RUTHENIUM, STRONTIUM AND CESIUM IN ENVIRONMENTAL AIR

    EPA Science Inventory

    In routine surveillance operations, the radionuclide measurement of air discharged from an operating nuclear facility involves the entrainment of radionuclides on selective filter or absorptive media, and the determination of their gross beta activity. However, a more sensitive t...

  5. Pavement thickness design for local roads in Iowa : tech brief.

    DOT National Transportation Integrated Search

    2010-01-01

    The main objectives of this research are to: 1) identify the most critical design input parameters, 2) determine the minimum pavement thickness, and 3) develop new pavement design and sensitivity analysis (PD&SA) software which can provide the most a...

  6. Facile and sensitive determination of N-nitrosamines in food samples by high-performance liquid chromatography via combining fluorescent labeling with dispersive liquid-liquid microextraction.

    PubMed

    Lu, Shuaimin; Wu, Di; Li, Guoliang; Lv, Zhengxian; Gong, Peiwei; Xia, Lian; Sun, Zhiwei; Chen, Guang; Chen, Xuefeng; You, Jinmao; Wu, Yongning

    2017-11-01

    The intake of N-nitrosamines (NAs) from foodstuffs is considered to be an important influence factor for several cancers. But the rapid and sensitive screening of NAs remains a challenge in the field of food safety. Inspired by that, a sensitive and rapid method was demonstrated for determination of five NAs (Nitrosopyrrolidine, Nitrosodimethylamine, Nitrosodiethylamine, Nitrosodipropylamine and Nitrosodibutylamine) using dispersive liquid-liquid microextraction (DLLME) followed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The NAs were firstly denitrosated and labeled by 2-(11H-benzo[a]carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) and finally enriched by DLLME. Furthermore, the main DLLME conditions were optimized systematically. Under the optimal conditions, satisfactory limits of detection (LODs) were obtained with a range of 0.01-0.07ngg -1 , which were significantly lower than the reported methods. The developed method showed many merits including rapidity, simplicity, high sensitivity and excellent selectivity, which shows a broad prospect in food safety analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Antibody against mutated citrullinated vimentin: a new sensitive marker in the diagnosis of rheumatoid arthritis.

    PubMed

    Wagner, Ernst; Skoumal, M; Bayer, P M; Klaushofer, K

    2009-09-01

    The aim of this study was to determine the performance of antibodies against mutated citrullinated vimentin (anti-MCV) in comparison with antibodies to cyclic citrullinated peptides (anti-CCP) in patients with rheumatoid arthritis (RA). Serum levels of anti-MCV and anti-CCP were determined in 193 patients with RA and 332 controls, and sensitivity and specificity were calculated. In a separate analysis of 86 patients, the anti-MCV levels were compared to disease activity. Sensitivity of anti-MCV versus anti-CCP was 71.5 and 69.4%, specificity was 81.3 and 97.6%, respectively. The ROC curves showed higher specificity and an advantage of anti-CCP. In seronegative RA patients the sensitivity of anti-MCV was superior over anti-CCP. Anti-MCV positivities also occurred in systemic lupus erythematosus and Sjoegren's syndrome. In a subgroup of 86 RA patients we found a significant correlation between anti-MCV and disease activity. Anti-MCV appears to be an important marker for the diagnosis of RA, and correlates also with disease activity.

  8. Analysis of single quantum-dot mobility inside 1D nanochannel devices

    NASA Astrophysics Data System (ADS)

    Hoang, H. T.; Segers-Nolten, I. M.; Tas, N. R.; van Honschoten, J. W.; Subramaniam, V.; Elwenspoek, M. C.

    2011-07-01

    We visualized individual quantum dots using a combination of a confining nanochannel and an ultra-sensitive microscope system, equipped with a high numerical aperture lens and a highly sensitive camera. The diffusion coefficients of the confined quantum dots were determined from the experimentally recorded trajectories according to the classical diffusion theory for Brownian motion in two dimensions. The calculated diffusion coefficients were three times smaller than those in bulk solution. These observations confirm and extend the results of Eichmann et al (2008 Langmuir 24 714-21) to smaller particle diameters and more narrow confinement. A detailed analysis shows that the observed reduction in mobility cannot be explained by conventional hydrodynamic theory.

  9. Validation of simple indexes to assess insulin sensitivity during pregnancy in Wistar and Sprague-Dawley rats.

    PubMed

    Cacho, J; Sevillano, J; de Castro, J; Herrera, E; Ramos, M P

    2008-11-01

    Insulin resistance plays a role in the pathogenesis of diabetes, including gestational diabetes. The glucose clamp is considered the gold standard for determining in vivo insulin sensitivity, both in human and in animal models. However, the clamp is laborious, time consuming and, in animals, requires anesthesia and collection of multiple blood samples. In human studies, a number of simple indexes, derived from fasting glucose and insulin levels, have been obtained and validated against the glucose clamp. However, these indexes have not been validated in rats and their accuracy in predicting altered insulin sensitivity remains to be established. In the present study, we have evaluated whether indirect estimates based on fasting glucose and insulin levels are valid predictors of insulin sensitivity in nonpregnant and 20-day-pregnant Wistar and Sprague-Dawley rats. We have analyzed the homeostasis model assessment of insulin resistance (HOMA-IR), the quantitative insulin sensitivity check index (QUICKI), and the fasting glucose-to-insulin ratio (FGIR) by comparing them with the insulin sensitivity (SI(Clamp)) values obtained during the hyperinsulinemic-isoglycemic clamp. We have performed a calibration analysis to evaluate the ability of these indexes to accurately predict insulin sensitivity as determined by the reference glucose clamp. Finally, to assess the reliability of these indexes for the identification of animals with impaired insulin sensitivity, performance of the indexes was analyzed by receiver operating characteristic (ROC) curves in Wistar and Sprague-Dawley rats. We found that HOMA-IR, QUICKI, and FGIR correlated significantly with SI(Clamp), exhibited good sensitivity and specificity, accurately predicted SI(Clamp), and yielded lower insulin sensitivity in pregnant than in nonpregnant rats. Together, our data demonstrate that these indexes provide an easy and accurate measure of insulin sensitivity during pregnancy in the rat.

  10. Assessment of nodal involvement in non-small-cell lung cancer with 18F-FDG-PET/CT: mediastinal blood pool cut-off has the highest sensitivity and tumour SUVmax/2 has the highest specificity.

    PubMed

    Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas

    2017-08-01

    Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.

  11. Determining the Best-Fit FPGA for a Space Mission: An Analysis of Cost, SEU Sensitivity,and Reliability

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Ken

    2007-01-01

    This viewgraph presentation reviews the selection of the optimum Field Programmable Gate Arrays (FPGA) for space missions. Included in this review is a discussion on differentiating amongst various FPGAs, cost analysis of the various options, the investigation of radiation effects, an expansion of the evaluation criteria, and the application of the evaluation criteria to the selection process.

  12. Measurements of 55Fe activity in activated steel samples with GEMPix

    NASA Astrophysics Data System (ADS)

    Curioni, A.; Dinar, N.; La Torre, F. P.; Leidner, J.; Murtas, F.; Puddu, S.; Silari, M.

    2017-03-01

    In this paper we present a novel method, based on the recently developed GEMPix detector, to measure the 55Fe content in samples of metallic material activated during operation of CERN accelerators and experimental facilities. The GEMPix, a gas detector with highly pixelated read-out, has been obtained by coupling a triple Gas Electron Multiplier (GEM) to a quad Timepix ASIC. Sample preparation, measurements performed on 45 samples and data analysis are described. The calibration factor (counts per second per unit specific activity) has been obtained via measurements of the 55Fe activity determined by radiochemical analysis of the same samples. Detection limit and sensitivity to the current Swiss exemption limit are calculated. Comparison with radiochemical analysis shows inconsistency for the sensitivity for only two samples, most likely due to underestimated uncertainties of the GEMPix analysis. An operative test phase of this technique is already planned at CERN.

  13. Combining EEG and MEG for the Reconstruction of Epileptic Activity Using a Calibrated Realistic Volume Conductor Model

    PubMed Central

    Aydin, Ümit; Vorwerk, Johannes; Küpper, Philipp; Heers, Marcel; Kugel, Harald; Galka, Andreas; Hamid, Laith; Wellmer, Jörg; Kellinghaus, Christoph; Rampp, Stefan; Wolters, Carsten Hermann

    2014-01-01

    To increase the reliability for the non-invasive determination of the irritative zone in presurgical epilepsy diagnosis, we introduce here a new experimental and methodological source analysis pipeline that combines the complementary information in EEG and MEG, and apply it to data from a patient, suffering from refractory focal epilepsy. Skull conductivity parameters in a six compartment finite element head model with brain anisotropy, constructed from individual MRI data, are estimated in a calibration procedure using somatosensory evoked potential (SEP) and field (SEF) data. These data are measured in a single run before acquisition of further runs of spontaneous epileptic activity. Our results show that even for single interictal spikes, volume conduction effects dominate over noise and need to be taken into account for accurate source analysis. While cerebrospinal fluid and brain anisotropy influence both modalities, only EEG is sensitive to skull conductivity and conductivity calibration significantly reduces the difference in especially depth localization of both modalities, emphasizing its importance for combining EEG and MEG source analysis. On the other hand, localization differences which are due to the distinct sensitivity profiles of EEG and MEG persist. In case of a moderate error in skull conductivity, combined source analysis results can still profit from the different sensitivity profiles of EEG and MEG to accurately determine location, orientation and strength of the underlying sources. On the other side, significant errors in skull modeling are reflected in EEG reconstruction errors and could reduce the goodness of fit to combined datasets. For combined EEG and MEG source analysis, we therefore recommend calibrating skull conductivity using additionally acquired SEP/SEF data. PMID:24671208

  14. High-precision drop shape analysis on inclining flat surfaces: introduction and comparison of this special method with commercial contact angle analysis.

    PubMed

    Schmitt, Michael; Heib, Florian

    2013-10-07

    Drop shape analysis is one of the most important and frequently used methods to characterise surfaces in the scientific and industrial communities. An especially large number of studies, which use contact angle measurements to analyse surfaces, are characterised by incorrect or misdirected conclusions such as the determination of surface energies from poorly performed contact angle determinations. In particular, the characterisation of surfaces, which leads to correlations between the contact angle and other effects, must be critically validated for some publications. A large number of works exist concerning the theoretical and thermodynamic aspects of two- and tri-phase boundaries. The linkage between theory and experiment is generally performed by an axisymmetric drop shape analysis, that is, simulations of the theoretical drop profiles by numerical integration onto a number of points of the drop meniscus (approximately 20). These methods work very well for axisymmetric profiles such as those obtained by pendant drop measurements, but in the case of a sessile drop onto real surfaces, additional unknown and misunderstood effects on the dependence of the surface must be considered. We present a special experimental and practical investigation as another way to transition from experiment to theory. This procedure was developed to be especially sensitive to small variations in the dependence of the dynamic contact angle on the surface; as a result, this procedure will allow the properties of the surface to be monitored with a higher precession and sensitivity. In this context, water drops onto a 111 silicon wafer are dynamically measured by video recording and by inclining the surface, which results in a sequence of non-axisymmetric drops. The drop profiles are analysed by commercial software and by the developed and presented high-precision drop shape analysis. In addition to the enhanced sensitivity for contact angle determination, this analysis technique, in combination with innovative fit algorithms and data presentations, can result in enhanced reproducibility and comparability of the contact angle measurements in terms of the material characterisation in a comprehensible way.

  15. High-precision drop shape analysis on inclining flat surfaces: Introduction and comparison of this special method with commercial contact angle analysis

    NASA Astrophysics Data System (ADS)

    Schmitt, Michael; Heib, Florian

    2013-10-01

    Drop shape analysis is one of the most important and frequently used methods to characterise surfaces in the scientific and industrial communities. An especially large number of studies, which use contact angle measurements to analyse surfaces, are characterised by incorrect or misdirected conclusions such as the determination of surface energies from poorly performed contact angle determinations. In particular, the characterisation of surfaces, which leads to correlations between the contact angle and other effects, must be critically validated for some publications. A large number of works exist concerning the theoretical and thermodynamic aspects of two- and tri-phase boundaries. The linkage between theory and experiment is generally performed by an axisymmetric drop shape analysis, that is, simulations of the theoretical drop profiles by numerical integration onto a number of points of the drop meniscus (approximately 20). These methods work very well for axisymmetric profiles such as those obtained by pendant drop measurements, but in the case of a sessile drop onto real surfaces, additional unknown and misunderstood effects on the dependence of the surface must be considered. We present a special experimental and practical investigation as another way to transition from experiment to theory. This procedure was developed to be especially sensitive to small variations in the dependence of the dynamic contact angle on the surface; as a result, this procedure will allow the properties of the surface to be monitored with a higher precession and sensitivity. In this context, water drops onto a 111 silicon wafer are dynamically measured by video recording and by inclining the surface, which results in a sequence of non-axisymmetric drops. The drop profiles are analysed by commercial software and by the developed and presented high-precision drop shape analysis. In addition to the enhanced sensitivity for contact angle determination, this analysis technique, in combination with innovative fit algorithms and data presentations, can result in enhanced reproducibility and comparability of the contact angle measurements in terms of the material characterisation in a comprehensible way.

  16. The Sensitivity and Specificity of Potassium Hydroxide Smear and Fungal Culture Relative to Clinical Assessment in the Evaluation of Tinea Pedis: A Pooled Analysis

    PubMed Central

    Levitt, Jacob Oren; Levitt, Barrie H.; Akhavan, Arash; Yanofsky, Howard

    2010-01-01

    Background. There are relatively few studies published examining the sensitivity and specificity of potassium hydroxide (KOH) smear and fungal culture examination of tinea pedis. Objective. To evaluate the sensitivity and specificity of KOH smear and fungal culture for diagnosing tinea pedis. Methods. A pooled analysis of data from five similarly conducted bioequivalence trials for antifungal drugs was performed. Data from 460 patients enrolled in the vehicle arms of these studies with clinical diagnosis of tinea pedis supported by positive fungal culture were analyzed 6 weeks after initiation of the study to determine the sensitivity and specificity of KOH smear and fungal culture. Results. Using clinical assessment as the gold standard, the sensitivities for KOH smear and culture were 73.3% (95% CI: 66.3 to 79.5%) and 41.7% (34.6 to 49.1%), respectively. The respective specificities for culture and KOH smear were 77.7% (72.2 to 82.5%) and 42.5% (36.6 to 48.6%). Conclusion. KOH smear and fungal culture are complementary diagnostic tests for tinea pedis, with the former being the more sensitive test of the two, and the latter being more specific. PMID:20672004

  17. Sensitivity Analysis of the Static Aeroelastic Response of a Wing

    NASA Technical Reports Server (NTRS)

    Eldred, Lloyd B.

    1993-01-01

    A technique to obtain the sensitivity of the static aeroelastic response of a three dimensional wing model is designed and implemented. The formulation is quite general and accepts any aerodynamic and structural analysis capability. A program to combine the discipline level, or local, sensitivities into global sensitivity derivatives is developed. A variety of representations of the wing pressure field are developed and tested to determine the most accurate and efficient scheme for representing the field outside of the aerodynamic code. Chebyshev polynomials are used to globally fit the pressure field. This approach had some difficulties in representing local variations in the field, so a variety of local interpolation polynomial pressure representations are also implemented. These panel based representations use a constant pressure value, a bilinearly interpolated value. or a biquadraticallv interpolated value. The interpolation polynomial approaches do an excellent job of reducing the numerical problems of the global approach for comparable computational effort. Regardless of the pressure representation used. sensitivity and response results with excellent accuracy have been produced for large integrated quantities such as wing tip deflection and trim angle of attack. The sensitivities of such things as individual generalized displacements have been found with fair accuracy. In general, accuracy is found to be proportional to the relative size of the derivatives to the quantity itself.

  18. Enhanced electrocatalytic oxidation of isoniazid at electrochemically modified rhodium electrode for biological and pharmaceutical analysis.

    PubMed

    Cheemalapati, Srikanth; Chen, Shen-Ming; Ali, M Ajmal; Al-Hemaid, Fahad M A

    2014-09-01

    A simple and sensitive electrochemical method has been proposed for the determination of isoniazid (INZ). For the first time, rhodium (Rh) modified glassy carbon electrode (GCE) has been employed for the determination of INZ by linear sweep voltammetry technique (LSV). Compared with the unmodified electrode, the proposed Rh modified electrode provides strong electrocatalytic activity toward INZ with significant enhancement in the anodic peak current. Scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM) results reveal the morphology of Rh particles. With the advantages of wide linearity (70-1300μM), good sensitivity (0.139μAμM(-1)cm(-2)) and low detection limit (13μM), this proposed sensor holds great potential for the determination of INZ in real samples. The practicality of the proposed electrode for the detection of INZ in human urine and blood plasma samples has been successfully demonstrated using LSV technique. Through the determination of INZ in commercially available pharmaceutical tablets, the practical applicability of the proposed method has been validated. The recovery results are found to be in good agreement with the labeled amounts of INZ in tablets, thus showing its great potential for use in clinical and pharmaceutical analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Modeling ozone episodes in the Baltimore-Washington region

    NASA Technical Reports Server (NTRS)

    Ryan, William F.

    1994-01-01

    Surface ozone (O3) concentrations in excess of the National Ambient Air Quality Standard (NAAQS) continue to occur in metropolitan areas in the United States despite efforts to control emissions of O3 precursors. Future O3 control strategies will be based on results from modeling efforts that have just begun in many areas. Two initial questions that arise are model sensitivity to domain-specific conditions and the selection of episodes for model evaluation and control strategy development. For the Baltimore-Washington region (B-W), the presence of the Chesapeake Bay introduces a number of issues relevant to model sensitivity. In this paper, the specific questions of the determination of model volume (mixing height) for the Urban Airshed Model (UAM) is discussed and various alternative methods compared. For the latter question, several analytic approaches, Cluster Analysis and classification and Regression Tree (CART) analysis are undertaken to determine meteorological conditions associated with severe O3 events in the B-W domain.

  20. The Stanford-U.S. Geological Survey SHRIMP ion microprobe--a tool for micro-scale chemical and isotopic analysis

    USGS Publications Warehouse

    Bacon, Charles R.; Grove, Marty; Vazquez, Jorge A.; Coble, Matthew A.

    2012-01-01

    Answers to many questions in Earth science require chemical analysis of minute volumes of minerals, volcanic glass, or biological materials. Secondary Ion Mass Spectrometry (SIMS) is an extremely sensitive analytical method in which a 5–30 micrometer diameter "primary" beam of charged particles (ions) is focused on a region of a solid specimen to sputter secondary ions from 1–5 nanograms of the sample under high vacuum. The elemental abundances and isotopic ratios of these secondary ions are determined with a mass spectrometer. These results can be used for geochronology to determine the age of a region within a crystal thousands to billions of years old or to precisely measure trace abundances of chemical elements at concentrations as low as parts per billion. A partnership of the U.S. Geological Survey and the Stanford University School of Earth Sciences operates a large SIMS instrument, the Sensitive High-Resolution Ion Microprobe with Reverse Geometry (SHRIMP–RG) on the Stanford campus.

  1. Using of multi-walled carbon nanotubes electrode for adsorptive stripping voltammetric determination of ultratrace levels of RDX explosive in the environmental samples.

    PubMed

    Rezaei, Behzad; Damiri, Sajjad

    2010-11-15

    A study of the electrochemical behavior and determination of RDX, a high explosive, is described on a multi-walled carbon nanotubes (MWCNTs) modified glassy carbon electrode (GCE) using adsorptive stripping voltammetry and electrochemical impedance spectroscopy (EIS) techniques. The results indicated that MWCNTs electrode remarkably enhances the sensitivity of the voltammetric method and provides measurements of this explosive down to the sub-mg/l level in a wide pH range. The operational parameters were optimized and a sensitive, simple and time-saving cyclic voltammetric procedure was developed for the analysis of RDX in ground and tap water samples. Under optimized conditions, the reduction peak have two linear dynamic ranges of 0.6-20.0 and 8.0-200.0 mM with a detection limit of 25.0 nM and a precision of <4% (RSD for 8 analysis). Copyright © 2010 Elsevier B.V. All rights reserved.

  2. A field instrument for quantitative determination of beryllium by activation analysis

    USGS Publications Warehouse

    Vaughn, William W.; Wilson, E.E.; Ohm, J.M.

    1960-01-01

    A low-cost instrument has been developed for quantitative determinations of beryllium in the field by activation analysis. The instrument makes use of the gamma-neutron reaction between gammas emitted by an artificially radioactive source (Sb124) and beryllium as it occurs in nature. The instrument and power source are mounted in a panel-type vehicle. Samples are prepared by hand-crushing the rock to approximately ?-inch mesh size and smaller. Sample volumes are kept constant by means of a standard measuring cup. Instrument calibration, made by using standards of known BeO content, indicates the analyses are reproducible and accurate to within ? 0.25 percent BeO in the range from 1 to 20 percent BeO with a sample counting time of 5 minutes. Sensitivity of the instrument maybe increased somewhat by increasing the source size, the sample size, or by enlarging the cross-sectional area of the neutron-sensitive phosphor normal to the neutron flux.

  3. Sensitive determination of trace mercury by UV-visible diffuse reflectance spectroscopy after complexation and membrane filtration-enrichment.

    PubMed

    Yin, Changhai; Iqbal, Jibran; Hu, Huilian; Liu, Bingxiang; Zhang, Lei; Zhu, Bilin; Du, Yiping

    2012-09-30

    A simple, sensitive and selective solid phase reflectometry method is proposed for the determination of trace mercury in aqueous samples. The complexation reagent dithizone was firstly injected into the properly buffered solution with vigorous stirring, which started a simultaneous formation of nanoparticles suspension of dithizone and its complexation reaction with the mercury(II) ions to make Hg-dithizone nanoparticles. After a definite time, the mixture was filtered with membrane, and then quantified directly on the surface of the membrane by using integrating sphere accessory of the UV-visible spectrophotometer. The quantitative analysis was carried out at a wavelength of 485 nm since it yielded the largest difference in diffuse reflectance spectra before and after reaction with mercury(II).A good linear correlation in the range of 0.2-4.0 μg/L with a squared correlation coefficient (R(2)) of 0.9944 and a detection limit of 0.12 μg/L were obtained. The accuracy of the method was evaluated by the analysis of spiked mercury(II) concentrations determined using this method along with those determined by the atomic fluorescence mercury vapourmeter and the results obtained were in good agreement. The proposed method was applied to the determination of mercury in tap water and river water samples with the recovery in an acceptable range (95.7-105.3%). Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay

    NASA Astrophysics Data System (ADS)

    Serebrennikova, Kseniya; Samsonova, Jeanne; Osipov, Alexander

    2018-06-01

    Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5-10 ng mL-1 with the limit of detection of 0.1 ng mL-1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies).

  5. Dysprosium-sensitized chemiluminescence system for the determination of enoxacin in pharmaceutical preparations and biological fluids with flow-injection sampling.

    PubMed

    Sun, Han-wen; Wu, Yuan-yuan; Li, Li-qing

    2009-03-01

    A novel trivalence dysprosium(Dy(3+))-sensitized chemiluminescence method was developed for the first time for the determination of enoxacin (ENX) using flow-injection sampling based on the chemiluminescence (CL) associated with the reaction of the Dy(3+)-cerium(Ce(IV))-S(2)O(3) (2-)-ENX system and the Dy(3+)-MnO(4) (-) S(2)O(3) (2-)-ENX system. The analytical conditions for CL emission were investigated and optimized. The relationship between the CL intensity of ENX and its concentration has good linearity, with a correlation coefficient of 0.9984-0.9994. The limit of detection (LOD, 3sigma) was 0.20 ng/mL for the Dy(3+)-ENX-S(2)O(3)(2-)-Ce(IV)-H(2)SO(4) system and 0.22 ng/mL for the Dy(3+)-ENX-S(2)O(3)(2-)-MnO(4) (-)-HNO(3) system. The relative standard deviation (RSD, n = 11) was 1.8% for 11 determinations of 60 ng/mL ENX. The proposed method was applied to the analysis of ENX in injections, serum and urine samples with a recovery of 98%-105%. A possible mechanism for this sensitized CL reaction is discussed by comparing the CL spectra with the fluorescence emission spectra. The proposed method represents a wide linear range, high sensitivity and accuracy, and can be used for the routine determination of ENX in pharmaceutical preparations and biological fluids. Copyright 2009 John Wiley & Sons, Ltd.

  6. Cholinesterase activity of muscle tissue from freshwater fishes: characterization and sensitivity analysis to the organophosphate methyl-paraoxon.

    PubMed

    Lopes, Renato Matos; Filho, Moacelio Veranio Silva; de Salles, João Bosco; Bastos, Vera Lúcia Freire Cunha; Bastos, Jayme Cunha

    2014-06-01

    The biochemical characterization of cholinesterases (ChE) from different teleost species has been a critical step in ensuring the proper use of ChE activity levels as biomarkers in environmental monitoring programs. In the present study, ChE from Oreochromis niloticus, Piaractus mesopotamicus, Leporinus macrocephalus, and Prochilodus lineatus was biochemically characterized by specific substrates and inhibitors. Moreover, muscle tissue ChE sensitivity to the organophosphate pesticide methyl-paraoxon was evaluated by determining the inhibition kinetic constants for its progressive irreversible inhibition by methyl-paraoxon as well as the 50% inhibitory concentration (IC50) for 30 min for each species. The present results indicate that acetylcholinesterase (AChE) must be present in the muscle from P. mesopotamicus, L. macrocephalus, and P. lineatus and that O. niloticus possesses an atypical cholinesterase or AChE and butyrylcholinesterase (BChE). Furthermore, there is a large difference regarding the sensitivity of these enzymes to methyl-paraoxon. The determined IC50 values for 30 min were 70 nM (O. niloticus), 258 nM (P. lineatus), 319 nM (L. macrocephalus), and 1578 nM (P. mesopotamicus). The results of the present study also indicate that the use of efficient methods for extracting these enzymes, their kinetic characterization, and determination of sensitivity differences between AChE and BChE to organophosphate compounds are essential for the determination of accurate ChE activity levels for environmental monitoring programs. © 2014 SETAC.

  7. Dual wavelength imaging allows analysis of membrane fusion of influenza virus inside cells.

    PubMed

    Sakai, Tatsuya; Ohuchi, Masanobu; Imai, Masaki; Mizuno, Takafumi; Kawasaki, Kazunori; Kuroda, Kazumichi; Yamashina, Shohei

    2006-02-01

    Influenza virus hemagglutinin (HA) is a determinant of virus infectivity. Therefore, it is important to determine whether HA of a new influenza virus, which can potentially cause pandemics, is functional against human cells. The novel imaging technique reported here allows rapid analysis of HA function by visualizing viral fusion inside cells. This imaging was designed to detect fusion changing the spectrum of the fluorescence-labeled virus. Using this imaging, we detected the fusion between a virus and a very small endosome that could not be detected previously, indicating that the imaging allows highly sensitive detection of viral fusion.

  8. Application of Monte Carlo Methods to Perform Uncertainty and Sensitivity Analysis on Inverse Water-Rock Reactions with NETPATH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGraw, David; Hershey, Ronald L.

    Methods were developed to quantify uncertainty and sensitivity for NETPATH inverse water-rock reaction models and to calculate dissolved inorganic carbon, carbon-14 groundwater travel times. The NETPATH models calculate upgradient groundwater mixing fractions that produce the downgradient target water chemistry along with amounts of mineral phases that are either precipitated or dissolved. Carbon-14 groundwater travel times are calculated based on the upgradient source-water fractions, carbonate mineral phase changes, and isotopic fractionation. Custom scripts and statistical code were developed for this study to facilitate modifying input parameters, running the NETPATH simulations, extracting relevant output, postprocessing the results, and producing graphs and summaries.more » The scripts read userspecified values for each constituent’s coefficient of variation, distribution, sensitivity parameter, maximum dissolution or precipitation amounts, and number of Monte Carlo simulations. Monte Carlo methods for analysis of parametric uncertainty assign a distribution to each uncertain variable, sample from those distributions, and evaluate the ensemble output. The uncertainty in input affected the variability of outputs, namely source-water mixing, phase dissolution and precipitation amounts, and carbon-14 travel time. Although NETPATH may provide models that satisfy the constraints, it is up to the geochemist to determine whether the results are geochemically reasonable. Two example water-rock reaction models from previous geochemical reports were considered in this study. Sensitivity analysis was also conducted to evaluate the change in output caused by a small change in input, one constituent at a time. Results were standardized to allow for sensitivity comparisons across all inputs, which results in a representative value for each scenario. The approach yielded insight into the uncertainty in water-rock reactions and travel times. For example, there was little variation in source-water fraction between the deterministic and Monte Carlo approaches, and therefore, little variation in travel times between approaches. Sensitivity analysis proved very useful for identifying the most important input constraints (dissolved-ion concentrations), which can reveal the variables that have the most influence on source-water fractions and carbon-14 travel times. Once these variables are determined, more focused effort can be applied to determining the proper distribution for each constraint. Second, Monte Carlo results for water-rock reaction modeling showed discrete and nonunique results. The NETPATH models provide the solutions that satisfy the constraints of upgradient and downgradient water chemistry. There can exist multiple, discrete solutions for any scenario and these discrete solutions cause grouping of results. As a result, the variability in output may not easily be represented by a single distribution or a mean and variance and care should be taken in the interpretation and reporting of results.« less

  9. SEE Sensitivity Analysis of 180 nm NAND CMOS Logic Cell for Space Applications

    NASA Astrophysics Data System (ADS)

    Sajid, Muhammad

    2016-07-01

    This paper focus on Single Event Effects caused by energetic particle strike on sensitive locations in CMOS NAND logic cell designed in 180nm technology node to be operated in space radiation environment. The generation of SE transients as well as upsets as function of LET of incident particle has been determined for logic devices onboard LEO and GEO satellites. The minimum magnitude pulse and pulse-width for threshold LET was determined to estimate the vulnerability /susceptibility of device for heavy ion strike. The impact of temperature, strike location and logic state of NAND circuit on total SEU/SET rate was estimated with physical mechanism simulations using Visual TCAD, Genius, runSEU program and Crad computer codes.

  10. Enhanced chemiluminescence for trazodone trace analysis based on acidic permanganate oxidation in concurrent presence of rhodamine 6G.

    PubMed

    Fujimori, Keiichi; Sakata, Yuta; Moriuchi-Kawakami, Takayo; Shibutani, Yasuhiko

    2017-11-01

    A new sensitized chemiluminescence method by acidic permanganate oxidation was developed for the sensitive determination of trazodone. A fluorescent dye as used rhodamine 6G to increase a chemiluminescence intensity. Under optimum conditions, the liner range of the calibration curve was obtained for 1-5000 nmol/L. The limit of detection was calculated from 3σ of a blank was 0.23 nmol/L. The coexistent ions and substances had no interference with the chemiluminescence measurement. The chemiluminescence spectra were measured to elucidate a possible mechanism for the system. The present method was satisfactorily used in the determination of the drugs in pharmaceutical samples and animal serums. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Refractometer assessment of colostral and serum IgG and milk total solids concentrations in dairy cattle

    PubMed Central

    2014-01-01

    Background Estimation of the quantity of colostral IgG or serum IgG absorbed following ingestion of colostrum by calves is essential for monitoring the effectiveness of colostrum feeding practices on dairy farms. Milk total solids concentrations determination is a critical part of quality assessment of nonsaleable whole milk prior to feeding to calves. To date, on-farm methods to assess colostral IgG, serum IgG or milk total solids concentrations have been performed separately with various instruments. The objective of this study was to evaluate the diagnostic performance of a single electronic, hand-held refractometer for assessing colostral and serum IgG concentrations and milk total solids in dairy cattle. Colostral IgG, serum IgG and milk total solids concentrations were determined by the refractometer. Corresponding analysis of colostral and serum IgG concentrations were determined by radial immunodiffusion (RID) while milk total solids were determined by spectrophotometry. Sensitivity and specificity of the refractometer for colostrum and serum samples were calculated as determined by RID. Sensitivity and specificity of the refractometer for milk samples was calculated as determined by spectrophotometry. Results The sensitivity of the refractometer was 1 for colostral IgG, serum IgG and milk total solids determinations. Specificity of the refractometer was 0.66, 0.24 and 0 for colostral IgG, serum IgG and milk total solids determinations, respectively. The refractometer underestimated colostral IgG, serum IgG and milk total solids concentrations compared to the concentrations determined by RID or spectrophotometry. Conclusions The refractometer was an acceptable, rapid, convenient on-farm method for determining colostral IgG and milk total solids. The refractometer was not an acceptable method for determination of serum IgG concentrations as it severely underestimated the serum IgG concentrations. PMID:25125217

  12. Aeroassisted orbit transfer vehicle trajectory analysis

    NASA Technical Reports Server (NTRS)

    Braun, Robert D.; Suit, William T.

    1988-01-01

    The emphasis in this study was on the use of multiple pass trajectories for aerobraking. However, for comparison, single pass trajectories, trajectories using ballutes, and trajectories corrupted by atmospheric anomolies were run. A two-pass trajectory was chosen to determine the relation between sensitivity to errors and payload to orbit. Trajectories that used only aerodynamic forces for maneuvering could put more weight into the target orbits but were very sensitive to variations from the planned trajectors. Using some thrust control resulted in less payload to orbit, but greatly reduced the sensitivity to variations from nominal trajectories. When compared to the non-thrusting trajectories investigated, the judicious use of thrusting resulted in multiple pass trajectories that gave 97 percent of the payload to orbit with almost none of the sensitivity to variations from the nominal.

  13. Enhanced detectability of fluorinated derivatives of N,N-dialkylamino alcohols and precursors of nitrogen mustards by gas chromatography coupled to Fourier transform infrared spectroscopy analysis for verification of chemical weapons convention.

    PubMed

    Garg, Prabhat; Purohit, Ajay; Tak, Vijay K; Dubey, D K

    2009-11-06

    N,N-Dialkylamino alcohols, N-methyldiethanolamine, N-ethyldiethanolamine and triethanolamine are the precursors of VX type nerve agents and three different nitrogen mustards respectively. Their detection and identification is of paramount importance for verification analysis of chemical weapons convention. GC-FTIR is used as complimentary technique to GC-MS analysis for identification of these analytes. One constraint of GC-FTIR, its low sensitivity, was overcome by converting the analytes to their fluorinated derivatives. Owing to high absorptivity in IR region, these derivatives facilitated their detection by GC-FTIR analysis. Derivatizing reagents having trimethylsilyl, trifluoroacyl and heptafluorobutyryl groups on imidazole moiety were screened. Derivatives formed there were analyzed by GC-FTIR quantitatively. Of these reagents studied, heptafluorobutyrylimidazole (HFBI) produced the greatest increase in sensitivity by GC-FTIR detection. 60-125 folds of sensitivity enhancement were observed for the analytes by HFBI derivatization. Absorbance due to various functional groups responsible for enhanced sensitivity were compared by determining their corresponding relative molar extinction coefficients ( [Formula: see text] ) considering uniform optical path length. The RSDs for intraday repeatability and interday reproducibility for various derivatives were 0.2-1.1% and 0.3-1.8%. Limit of detection (LOD) was achieved up to 10-15ng and applicability of the method was tested with unknown samples obtained in international proficiency tests.

  14. Contamination of grazing incidence EUV mirrors - An assessment

    NASA Technical Reports Server (NTRS)

    Osantowski, John F.; Fleetwood, C. F.

    1988-01-01

    Contamination assessment for space optical systems requires an understanding of the sensitivity of component performance, e.g. mirror reflectance, to materials deposited on the mirror surface. In a previous study, the sensitivity of typical normal incidence mirror coatings to surface deposits of generic hydrocarbons was reported. Recent activity in the development of grazing incidence telescopes for extreme ultraviolet space astronomy has stimulated the need for a similar assessment in the spectral region extending from approximately 100 A to 1000 A. The model used for analysis treats the contamination layer as a continuous thin film deposited on the mirror surface. The mirror surfaces selected for this study are opaque vacuum deposited gold and the uncoated and polished Zerodur. Scatter caused by film irregularities or particulates are not included in this assessment. Parametric evaluations at 100, 500, and 1000 A determine the sensitivity of mirror reflectance to a range of optical constants selected for the generic contaminants. This sensitivity analysis combined with the limited amount of optical data in the EUV for hydrocarbons, is used to select representative optical constants for the three wavelength regions. Reflectance versus contamination layer thickness curves are then calculated and used to determine critical thickness limits based on allowable reflectance change. Initial observations indicate that thickness limits will be highly dependent on the real part of the complex index of refraction of the contaminant film being less than 1.0. Preliminary laboratory measurements of samples contaminated with some commonly encountered hydrocarbons confirm trends indicated in the analytical studies.

  15. A Novel Methylation PCR that Offers Standardized Determination of FMR1 Methylation and CGG Repeat Length without Southern Blot Analysis

    PubMed Central

    Grasso, Marina; Boon, Elles M.J.; Filipovic-Sadic, Stela; van Bunderen, Patrick A.; Gennaro, Elena; Cao, Ru; Latham, Gary J.; Hadd, Andrew G.; Coviello, Domenico A.

    2015-01-01

    Fragile X syndrome and associated disorders are characterized by the number of CGG repeats and methylation status of the FMR1 gene for which Southern blot (SB) historically has been required for analysis. This study describes a simple PCR-only workflow (mPCR) to replace SB analysis, that incorporates novel procedural controls, treatment of the DNA in separate control and methylation-sensitive restriction endonuclease reactions, amplification with labeled primers, and two-color amplicon sizing by capillary electrophoresis. mPCR was evaluated in two independent laboratories with 76 residual clinical samples that represented typical and challenging fragile X alleles in both males and females. mPCR enabled superior size resolution and analytical sensitivity for size and methylation mosaicism compared to SB. Full mutation mosaicism was detected down to 1% in a background of 99% normal allele with 50- to 100-fold less DNA than required for SB. A low level of full mutation mosaicism in one sample was detected using mPCR but not observed using SB. Overall, the sensitivity for detection of full mutation alleles was 100% (95% CI: 89%–100%) with an accuracy of 99% (95% CI: 93%–100%). mPCR analysis of DNA from individuals with Klinefelter and Turner syndromes, and DNA from sperm and blood, were consistent with SB. As such, mPCR enables accurate, sensitive, and standardized methods of FMR1 analysis that can harmonize results across different laboratories. PMID:24177047

  16. Surrogacy of progression-free survival (PFS) for overall survival (OS) in esophageal cancer trials with preoperative therapy: Literature-based meta-analysis.

    PubMed

    Kataoka, K; Nakamura, K; Mizusawa, J; Kato, K; Eba, J; Katayama, H; Shibata, T; Fukuda, H

    2017-10-01

    There have been no reports evaluating progression-free survival (PFS) as a surrogate endpoint in resectable esophageal cancer. This study was conducted to evaluate the trial level correlations between PFS and overall survival (OS) in resectable esophageal cancer with preoperative therapy and to explore the potential benefit of PFS as a surrogate endpoint for OS. A systematic literature search of randomized trials with preoperative chemotherapy or preoperative chemoradiotherapy for esophageal cancer reported from January 1990 to September 2014 was conducted using PubMed and the Cochrane Library. Weighted linear regression using sample size of each trial as a weight was used to estimate coefficient of determination (R 2 ) within PFS and OS. The primary analysis included trials in which the HR for both PFS and OS was reported. The sensitivity analysis included trials in which either HR or median survival time of PFS and OS was reported. In the sensitivity analysis, HR was estimated from the median survival time of PFS and OS, assuming exponential distribution. Of 614 articles, 10 trials were selected for the primary analysis and 15 for the sensitivity analysis. The primary analysis did not show a correlation between treatment effects on PFS and OS (R 2 0.283, 95% CI [0.00-0.90]). The sensitivity analysis did not show an association between PFS and OS (R 2 0.084, 95% CI [0.00-0.70]). Although the number of randomized controlled trials evaluating preoperative therapy for esophageal cancer is limited at the moment, PFS is not suitable for primary endpoint as a surrogate endpoint for OS. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  17. Instrumentation and Performance Analysis Plans for the HIFiRE Flight 2 Experiment

    NASA Technical Reports Server (NTRS)

    Gruber, Mark; Barhorst, Todd; Jackson, Kevin; Eklund, Dean; Hass, Neal; Storch, Andrea M.; Liu, Jiwen

    2009-01-01

    Supersonic combustion performance of a bi-component gaseous hydrocarbon fuel mixture is one of the primary aspects under investigation in the HIFiRE Flight 2 experiment. In-flight instrumentation and post-test analyses will be two key elements used to determine the combustion performance. Pre-flight computational fluid dynamics (CFD) analyses provide valuable information that can be used to optimize the placement of a constrained set of wall pressure instrumentation in the experiment. The simulations also allow pre-flight assessments of performance sensitivities leading to estimates of overall uncertainty in the determination of combustion efficiency. Based on the pre-flight CFD results, 128 wall pressure sensors have been located throughout the isolator/combustor flowpath to minimize the error in determining the wall pressure force at Mach 8 flight conditions. Also, sensitivity analyses show that mass capture and combustor exit stream thrust are the two primary contributors to uncertainty in combustion efficiency.

  18. [Induction, regeneration, and biolistic sensitivity of different genotypes of common wheat (Triticum aestivum L.)].

    PubMed

    Fadeev, V S; Shimshilashvili, Kh R; Gaponenko, A K

    2008-09-01

    The induction, regeneration, and biolistic sensitivities of different genotypes of common wheat (Triticum aestivum L.) have been determined in order to develop an efficient system for transformation of Russian cultivars of spring wheat. Short-term (two days) cold treatment (4 degrees C) has been demonstrated to distinctly increase the frequency of morphogenetic callus induction. The optimal phytohormonal composition of the nutrient medium ensuring an in vitro regeneration rate of the common wheat cultivar Lada as high as 90% has been determined. The optimal temporal parameters of genetic transformation of wheat plants (10-14 days of culturing after initiation of a morphogenetic callus) have been determined for two transformation methods: biolistic without precipitated DNA and transformation with the plasmid psGFP-BAR. Analysis of the transient expression of the gfp gene has confirmed that 14 days of culturing is the optimal duration.

  19. High-performance liquid chromatographic determination of the beta2-selective adrenergic agonist fenoterol in human plasma after fluorescence derivatization.

    PubMed

    Kramer, S; Blaschke, G

    2001-02-10

    A sensitive high-performance liquid chromatographic method has been developed for the determination of the beta2-selective adrenergic agonist fenoterol in human plasma. To improve the sensitivity of the method, fenoterol was derivatized with N-(chloroformyl)-carbazole prior to HPLC analysis yielding highly fluorescent derivatives. The assay involves protein precipitation with acetonitrile, liquid-liquid-extraction of fenoterol from plasma with isobutanol under alkaline conditions followed by derivatization with N-(chloroformyl)-carbazole. Reversed-phase liquid chromatographic determination of the fenoterol derivative was performed using a column-switching system consisting of a LiChrospher 100 RP 18 and a LiChrospher RP-Select B column with acetonitrile, methanol and water as mobile phase. The limit of quantitation in human plasma was 376 pg fenoterol/ml. The method was successfully applied for the assay of fenoterol in patient plasma.

  20. THE DETERMINATION OF MICROGRAM AND SUB-MICROGRAM AMOUNTS OF BORON. PART I. ABSORPTIOMETRIC DETERMINATION USING CURCUMIN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spicer, G.S.; Strickland, J.D.H.

    1958-03-01

    Three methods are described for the absorptiometric determination of boron present in alkaline residues in a platinum dish. These are based on the reaction of boric acid and a curcumin reagent to form the red compounds rubrocurcumin and rosocyanin. The first method is suitable for quantities of the element between about 2 and 15 mu g the second is best used when between 0.5 and 4 mu g are present and the third when the highest sensitivity is required, 0.01 to 0.2 mu g. The last method does not involve the use of an oxalic acid promotor and is thoughtmore » to give the maximum sensitivity possible for any absorptiometric technique. The three procedures were developed and have been used over the last decade for the analysis of atomic orough testing under routine conditions. (auth)« less

  1. Personality moderates the links of social identity with work motivation and job searching.

    PubMed

    Baay, Pieter E; van Aken, Marcel A G; van der Lippe, Tanja; de Ridder, Denise T D

    2014-01-01

    Work motivation is critical for successful school-to-work transitions, but little is known about its determinants among labor market entrants. Applying a social identity framework, we examined whether work motivation and job searching are social-contextually determined. We expected that some job seekers are more sensitive to contextual influence, depending on their personality. Mediation analyses on 591 Dutch vocational training students indicate that the perception of more positive work norms in someone's social context was related to higher levels of intrinsic motivation, which in turn predicted higher preparatory job search behavior and job search intentions. Multi-group analysis shows that perceived work norms more strongly predict work motivation among overcontrollers compared to resilients and undercontrollers. In conclusion, work motivation and job searching appear contextually determined: especially among those sensitive to contextual influence, people seem to work when they believe that is what people like them do.

  2. Development of procedures for calculating stiffness and damping of elastomers in engineering applications. Part 5: Elastomer performance limits and the design and test of an elastomer damper

    NASA Technical Reports Server (NTRS)

    Tecza, J. A.; Darlow, M. S.; Smalley, A. J.

    1979-01-01

    Tests were performed on elastomer specimens of the material polybutadiene to determine the performance limitations imposed by strain, temperature, and frequency. Three specimens were tested: a shear specimen, a compression specimen, and a second compression specimen in which thermocouples were embedded in the elastomer buttons. Stiffness and damping were determined from all tests, and internal temperatures were recorded for the instrumented compression specimen. Measured results are presented together with comparisons between predictions of a thermo-viscoelastic analysis and the measured results. Dampers of polybutadiene and Viton were designed, built, and tested. Vibration measurements were made and sensitivity of vibration to change in unbalance was also determined. Values for log decrement were extracted from the synchronous response curves. Comparisons were made between measured sensitivity to unbalance and log decrement and predicted values for these quantities.

  3. Finding the bottom and using it

    PubMed Central

    Sandoval, Ruben M.; Wang, Exing; Molitoris, Bruce A.

    2014-01-01

    Maximizing 2-photon parameters used in acquiring images for quantitative intravital microscopy, especially when high sensitivity is required, remains an open area of investigation. Here we present data on correctly setting the black level of the photomultiplier tube amplifier by adjusting the offset to allow for accurate quantitation of low intensity processes. When the black level is set too high some low intensity pixel values become zero and a nonlinear degradation in sensitivity occurs rendering otherwise quantifiable low intensity values virtually undetectable. Initial studies using a series of increasing offsets for a sequence of concentrations of fluorescent albumin in vitro revealed a loss of sensitivity for higher offsets at lower albumin concentrations. A similar decrease in sensitivity, and therefore the ability to correctly determine the glomerular permeability coefficient of albumin, occurred in vivo at higher offset. Finding the offset that yields accurate and linear data are essential for quantitative analysis when high sensitivity is required. PMID:25313346

  4. Sensitivity of the Positive and Negative Syndrome Scale (PANSS) in Detecting Treatment Effects via Network Analysis.

    PubMed

    Esfahlani, Farnaz Zamani; Sayama, Hiroki; Visser, Katherine Frost; Strauss, Gregory P

    2017-12-01

    Objective: The Positive and Negative Syndrome Scale is a primary outcome measure in clinical trials examining the efficacy of antipsychotic medications. Although the Positive and Negative Syndrome Scale has demonstrated sensitivity as a measure of treatment change in studies using traditional univariate statistical approaches, its sensitivity to detecting network-level changes in dynamic relationships among symptoms has yet to be demonstrated using more sophisticated multivariate analyses. In the current study, we examined the sensitivity of the Positive and Negative Syndrome Scale to detecting antipsychotic treatment effects as revealed through network analysis. Design: Participants included 1,049 individuals diagnosed with psychotic disorders from the Phase I portion of the Clinical Antipsychotic Trials of Intervention Effectiveness (CATIE) study. Of these participants, 733 were clinically determined to be treatment-responsive and 316 were found to be treatment-resistant. Item level data from the Positive and Negative Syndrome Scale were submitted to network analysis, and macroscopic, mesoscopic, and microscopic network properties were evaluated for the treatment-responsive and treatment-resistant groups at baseline and post-phase I antipsychotic treatment. Results: Network analysis indicated that treatment-responsive patients had more densely connected symptom networks after antipsychotic treatment than did treatment-responsive patients at baseline, and that symptom centralities increased following treatment. In contrast, symptom networks of treatment-resistant patients behaved more randomly before and after treatment. Conclusions: These results suggest that the Positive and Negative Syndrome Scale is sensitive to detecting treatment effects as revealed through network analysis. Its findings also provide compelling new evidence that strongly interconnected symptom networks confer an overall greater probability of treatment responsiveness in patients with psychosis, suggesting that antipsychotics achieve their effect by enhancing a number of central symptoms, which then facilitate reduction of other highly coupled symptoms in a network-like fashion.

  5. Accuracy analysis and design of A3 parallel spindle head

    NASA Astrophysics Data System (ADS)

    Ni, Yanbing; Zhang, Biao; Sun, Yupeng; Zhang, Yuan

    2016-03-01

    As functional components of machine tools, parallel mechanisms are widely used in high efficiency machining of aviation components, and accuracy is one of the critical technical indexes. Lots of researchers have focused on the accuracy problem of parallel mechanisms, but in terms of controlling the errors and improving the accuracy in the stage of design and manufacturing, further efforts are required. Aiming at the accuracy design of a 3-DOF parallel spindle head(A3 head), its error model, sensitivity analysis and tolerance allocation are investigated. Based on the inverse kinematic analysis, the error model of A3 head is established by using the first-order perturbation theory and vector chain method. According to the mapping property of motion and constraint Jacobian matrix, the compensatable and uncompensatable error sources which affect the accuracy in the end-effector are separated. Furthermore, sensitivity analysis is performed on the uncompensatable error sources. The sensitivity probabilistic model is established and the global sensitivity index is proposed to analyze the influence of the uncompensatable error sources on the accuracy in the end-effector of the mechanism. The results show that orientation error sources have bigger effect on the accuracy in the end-effector. Based upon the sensitivity analysis results, the tolerance design is converted into the issue of nonlinearly constrained optimization with the manufacturing cost minimum being the optimization objective. By utilizing the genetic algorithm, the allocation of the tolerances on each component is finally determined. According to the tolerance allocation results, the tolerance ranges of ten kinds of geometric error sources are obtained. These research achievements can provide fundamental guidelines for component manufacturing and assembly of this kind of parallel mechanisms.

  6. Evaluation of Visual Field Progression in Glaucoma: Quasar Regression Program and Event Analysis.

    PubMed

    Díaz-Alemán, Valentín T; González-Hernández, Marta; Perera-Sanz, Daniel; Armas-Domínguez, Karintia

    2016-01-01

    To determine the sensitivity, specificity and agreement between the Quasar program, glaucoma progression analysis (GPA II) event analysis and expert opinion in the detection of glaucomatous progression. The Quasar program is based on linear regression analysis of both mean defect (MD) and pattern standard deviation (PSD). Each series of visual fields was evaluated by three methods; Quasar, GPA II and four experts. The sensitivity, specificity and agreement (kappa) for each method was calculated, using expert opinion as the reference standard. The study included 439 SITA Standard visual fields of 56 eyes of 42 patients, with a mean of 7.8 ± 0.8 visual fields per eye. When suspected cases of progression were considered stable, sensitivity and specificity of Quasar, GPA II and the experts were 86.6% and 70.7%, 26.6% and 95.1%, and 86.6% and 92.6% respectively. When suspected cases of progression were considered as progressing, sensitivity and specificity of Quasar, GPA II and the experts were 79.1% and 81.2%, 45.8% and 90.6%, and 85.4% and 90.6% respectively. The agreement between Quasar and GPA II when suspected cases were considered stable or progressing was 0.03 and 0.28 respectively. The degree of agreement between Quasar and the experts when suspected cases were considered stable or progressing was 0.472 and 0.507. The degree of agreement between GPA II and the experts when suspected cases were considered stable or progressing was 0.262 and 0.342. The combination of MD and PSD regression analysis in the Quasar program showed better agreement with the experts and higher sensitivity than GPA II.

  7. PeTTSy: a computational tool for perturbation analysis of complex systems biology models.

    PubMed

    Domijan, Mirela; Brown, Paul E; Shulgin, Boris V; Rand, David A

    2016-03-10

    Over the last decade sensitivity analysis techniques have been shown to be very useful to analyse complex and high dimensional Systems Biology models. However, many of the currently available toolboxes have either used parameter sampling, been focused on a restricted set of model observables of interest, studied optimisation of a objective function, or have not dealt with multiple simultaneous model parameter changes where the changes can be permanent or temporary. Here we introduce our new, freely downloadable toolbox, PeTTSy (Perturbation Theory Toolbox for Systems). PeTTSy is a package for MATLAB which implements a wide array of techniques for the perturbation theory and sensitivity analysis of large and complex ordinary differential equation (ODE) based models. PeTTSy is a comprehensive modelling framework that introduces a number of new approaches and that fully addresses analysis of oscillatory systems. It examines sensitivity analysis of the models to perturbations of parameters, where the perturbation timing, strength, length and overall shape can be controlled by the user. This can be done in a system-global setting, namely, the user can determine how many parameters to perturb, by how much and for how long. PeTTSy also offers the user the ability to explore the effect of the parameter perturbations on many different types of outputs: period, phase (timing of peak) and model solutions. PeTTSy can be employed on a wide range of mathematical models including free-running and forced oscillators and signalling systems. To enable experimental optimisation using the Fisher Information Matrix it efficiently allows one to combine multiple variants of a model (i.e. a model with multiple experimental conditions) in order to determine the value of new experiments. It is especially useful in the analysis of large and complex models involving many variables and parameters. PeTTSy is a comprehensive tool for analysing large and complex models of regulatory and signalling systems. It allows for simulation and analysis of models under a variety of environmental conditions and for experimental optimisation of complex combined experiments. With its unique set of tools it makes a valuable addition to the current library of sensitivity analysis toolboxes. We believe that this software will be of great use to the wider biological, systems biology and modelling communities.

  8. A special protection scheme utilizing trajectory sensitivity analysis in power transmission

    NASA Astrophysics Data System (ADS)

    Suriyamongkol, Dan

    In recent years, new measurement techniques have provided opportunities to improve the North American Power System observability, control and protection. This dissertation discusses the formulation and design of a special protection scheme based on a novel utilization of trajectory sensitivity techniques with inputs consisting of system state variables and parameters. Trajectory sensitivity analysis (TSA) has been used in previous publications as a method for power system security and stability assessment, and the mathematical formulation of TSA lends itself well to some of the time domain power system simulation techniques. Existing special protection schemes often have limited sets of goals and control actions. The proposed scheme aims to maintain stability while using as many control actions as possible. The approach here will use the TSA in a novel way by using the sensitivities of system state variables with respect to state parameter variations to determine the state parameter controls required to achieve the desired state variable movements. The initial application will operate based on the assumption that the modeled power system has full system observability, and practical considerations will be discussed.

  9. Ethylene responsive factor ERF110 mediates ethylene-regulated transcription of a sex determination-related orthologous gene in two Cucumis species.

    PubMed

    Tao, Qianyi; Niu, Huanhuan; Wang, Zhongyuan; Zhang, Wenhui; Wang, Hu; Wang, Shenhao; Zhang, Xian; Li, Zheng

    2018-05-25

    In plants, unisexual flowers derived from developmental sex determination form separate stamens and pistils that facilitate cross pollination. In cucumber and melon, ethylene plays a key role in sex determination. Six sex determination-related genes have been identified in ethylene biosynthesis in these Cucumis species. The interactions among these genes are thought to involve ethylene signaling; however, the underlying mechanism of regulation remains unknown. In this study, hormone treatment and qPCR assays were used to confirm expression of these sex determination-related genes in cucumber and melon is ethylene sensitive. RNA-Seq analysis subsequently helped identify the ethylene responsive factor (ERF) gene, CsERF110, related to ethylene signaling and sex determination. CsERF110 and its melon ortholog, CmERF110, shared a conserved AP2/ERF domain and showed ethylene-sensitive expression. Yeast one-hybrid and ChIP-PCR assays further indicated that CsERF110 bound to at least two sites in the promoter fragment of CsACS11, while transient transformation analysis showed that CsERF110 and CmERF110 enhance CsACS11 and CmACS11 promoter activity, respectively. Taken together, these findings suggest that CsERF110 and CmERF110 respond to ethylene signaling, mediating ethylene-regulated transcription of CsACS11 and CmACS11 in cucumber and melon, respectively. Furthermore, the mechanism involved in its regulation is thought to be conserved in these two Cucumis species.

  10. Ultrafast UPLC-ESI-MS and HPLC with monolithic column for determination of principal flavor compounds in vanilla pods.

    PubMed

    Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P

    2009-10-01

    In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.

  11. Wear-Out Sensitivity Analysis Project Abstract

    NASA Technical Reports Server (NTRS)

    Harris, Adam

    2015-01-01

    During the course of the Summer 2015 internship session, I worked in the Reliability and Maintainability group of the ISS Safety and Mission Assurance department. My project was a statistical analysis of how sensitive ORU's (Orbital Replacement Units) are to a reliability parameter called the wear-out characteristic. The intended goal of this was to determine a worst case scenario of how many spares would be needed if multiple systems started exhibiting wear-out characteristics simultaneously. The goal was also to determine which parts would be most likely to do so. In order to do this, my duties were to take historical data of operational times and failure times of these ORU's and use them to build predictive models of failure using probability distribution functions, mainly the Weibull distribution. Then, I ran Monte Carlo Simulations to see how an entire population of these components would perform. From here, my final duty was to vary the wear-out characteristic from the intrinsic value, to extremely high wear-out values and determine how much the probability of sufficiency of the population would shift. This was done for around 30 different ORU populations on board the ISS.

  12. Microfluidic Flow Injection Analysis with Thermal Lens Microscopic Detection for Determination of NGAL

    NASA Astrophysics Data System (ADS)

    Radovanović, Tatjana; Liu, Mingqiang; Likar, Polona; Klemenc, Matjaž; Franko, Mladen

    2015-06-01

    A combined microfluidic flow injection analysis-thermal lens microscopy (FIA-TLM) system was applied for determination of neutrophil gelatinase-associated lipocalin (NGAL)—a biomarker of acute kidney injury. NGAL was determined following a commercial ELISA assay and transfer of the resulting solution into the FIA-TLM system with a 100 m deep microchannel. At an excitation power of 100 mW, the FIA-TLM provided about seven times lower limits of detection (1.5 pg as compared to a conventional ELISA test, and a sample throughput of six samples per minute, which compares favorably with sample throughput of the microtiter plate reader, which reads 96 wells in about 30 min. Comparison of results for NGAL in plasma samples from healthy individuals and for NGAL dynamics in patients undergoing coronary angiography measured with transmission mode spectrometry on a microtiter plate reader and with FIA-TLM showed good agreement. In addition to improved LOD, the high sensitivity of FIA-TLM offers possibilities of a further reduction of the total reaction time of the NGAL ELISA test by sacrificing some of the sensitivity while reducing the duration of individual incubation steps.

  13. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    NASA Astrophysics Data System (ADS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Záray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-11-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2O 3. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection limits of 170 ng/l of As in xylem sap were achieved.

  14. Autophagic cell death induced by reactive oxygen species is involved in hyperthermic sensitization to ionizing radiation in human hepatocellular carcinoma cells.

    PubMed

    Yuan, Guang-Jin; Deng, Jun-Jian; Cao, De-Dong; Shi, Lei; Chen, Xin; Lei, Jin-Ju; Xu, Xi-Ming

    2017-08-14

    To investigate whether autophagic cell death is involved in hyperthermic sensitization to ionizing radiation in human hepatocellular carcinoma cells, and to explore the underlying mechanism. Human hepatocellular carcinoma cells were treated with hyperthermia and ionizing radiation. MTT and clonogenic assays were performed to determine cell survival. Cell autophagy was detected using acridine orange staining and flow cytometric analysis, and the expression of autophagy-associated proteins, LC3 and p62, was determined by Western blot analysis. Intracellular reactive oxygen species (ROS) were quantified using the fluorescent probe DCFH-DA. Treatment with hyperthermia and ionizing radiation significantly decreased cell viability and surviving fraction as compared with hyperthermia or ionizing radiation alone. Cell autophagy was significantly increased after ionizing radiation combined with hyperthermia treatment, as evidenced by increased formation of acidic vesicular organelles, increased expression of LC3II and decreased expression of p62. Intracellular ROS were also increased after combined treatment with hyperthermia and ionizing radiation. Pretreatment with N-acetylcysteine, an ROS scavenger, markedly inhibited the cytotoxicity and cell autophagy induced by hyperthermia and ionizing radiation. Autophagic cell death is involved in hyperthermic sensitization of cancer cells to ionizing radiation, and its induction may be due to the increased intracellular ROS.

  15. Receiver Operating Characteristic Curve Analysis of Beach Water Quality Indicator Variables

    PubMed Central

    Morrison, Ann Michelle; Coughlin, Kelly; Shine, James P.; Coull, Brent A.; Rex, Andrea C.

    2003-01-01

    Receiver operating characteristic (ROC) curve analysis is a simple and effective means to compare the accuracies of indicator variables of bacterial beach water quality. The indicator variables examined in this study were previous day's Enterococcus density and antecedent rainfall at 24, 48, and 96 h. Daily Enterococcus densities and 15-min rainfall values were collected during a 5-year (1996 to 2000) study of four Boston Harbor beaches. The indicator variables were assessed for their ability to correctly classify water as suitable or unsuitable for swimming at a maximum threshold Enterococcus density of 104 CFU/100 ml. Sensitivity and specificity values were determined for each unique previous day's Enterococcus density and antecedent rainfall volume and used to construct ROC curves. The area under the ROC curve was used to compare the accuracies of the indicator variables. Twenty-four-hour antecedent rainfall classified elevated Enterococcus densities more accurately than previous day's Enterococcus density (P = 0.079). An empirically derived threshold for 48-h antecedent rainfall, corresponding to a sensitivity of 0.75, was determined from the 1996 to 2000 data and evaluated to ascertain if the threshold would produce a 0.75 sensitivity with independent water quality data collected in 2001 from the same beaches. PMID:14602593

  16. Relationship between interpersonal sensitivity and leukocyte telomere length.

    PubMed

    Suzuki, Akihito; Matsumoto, Yoshihiko; Enokido, Masanori; Shirata, Toshinori; Goto, Kaoru; Otani, Koichi

    2017-10-10

    Telomeres are repetitive DNA sequences located at the ends of chromosomes, and telomere length represents a biological marker for cellular aging. Interpersonal sensitivity, excessive sensitivity to the behavior and feelings of others, is one of the vulnerable factors to depression. In the present study, we examined the effect of interpersonal sensitivity on telomere length in healthy subjects. The subjects were 159 unrelated healthy Japanese volunteers. Mean age ± SD (range) of the subjects was 42.3 ± 7.8 (30-61) years. Interpersonal sensitivity was assessed by the Japanese version of the Interpersonal Sensitivity Measure (IPSM). Leukocyte telomere length was determined by a quantitative real-time PCR method. Higher scores of the total IPSM were significantly (β = -0.163, p = 0.038) related to shorter telomere length. In the sub-scale analysis, higher scores of timidity were significantly (β = -0.220, p = 0.044) associated with shorter telomere length. The present study suggests that subjects with higher interpersonal sensitivity have shorter leukocyte telomere length, implying that interpersonal sensitivity has an impact on cellular aging.

  17. Optimizing sensitivity to γ with B0→D K+π-, D →KS0π+π- double Dalitz plot analysis

    NASA Astrophysics Data System (ADS)

    Craik, D.; Gershon, T.; Poluektov, A.

    2018-03-01

    Two of the most powerful methods currently used to determine the angle γ of the CKM Unitarity Triangle exploit B+→D K+, D →KS0π+π- decays and B0→D K+π-, D →K+K-, π+π- decays. It is possible to combine the strengths of both approaches in a "double Dalitz plot" analysis of B0→D K+π-, D →KS0π+π- decays. The potential sensitivity of such an analysis is investigated in the light of recently published experimental information on the B0→D K+π- decay. The formalism is also expanded, compared to previous discussions in the literature, to allow B0→D K+π- with any subsequent D decay to be included.

  18. True covariance simulation of the EUVE update filter

    NASA Technical Reports Server (NTRS)

    Bar-Itzhack, Itzhack Y.; Harman, R. R.

    1989-01-01

    A covariance analysis of the performance and sensitivity of the attitude determination Extended Kalman Filter (EKF) used by the On Board Computer (OBC) of the Extreme Ultra Violet Explorer (EUVE) spacecraft is presented. The linearized dynamics and measurement equations of the error states are derived which constitute the truth model describing the real behavior of the systems involved. The design model used by the OBC EKF is then obtained by reducing the order of the truth model. The covariance matrix of the EKF which uses the reduced order model is not the correct covariance of the EKF estimation error. A true covariance analysis has to be carried out in order to evaluate the correct accuracy of the OBC generated estimates. The results of such analysis are presented which indicate both the performance and the sensitivity of the OBC EKF.

  19. Determination of methylamines in air using activated charcoal traps and gas chromatographic analysis with an alkali flame detector (AFD)

    NASA Astrophysics Data System (ADS)

    Fuselli, Sergio; Benedetti, Giorgio; Mastrangeli, Renato

    A method is described for trapping and analysing airborne methylamines (MMA, DMA and TMA) by means of a 20/35 mesh activated charcoal traps and subsequent GLSC analysis of collected sample using 0.1 N NaOH acqueous solution. The method described may be applied to monitoring methylamines in air in industrial areas, with an Alkali Flame Detector; sensitivities of approx. 0.005 ppmv for each of the three methylamines analysed are reached. Trapping efficiency is compared with that of Tenax GC 60/80 mesh and 60/80 Carbopack B which uses thermal desorption of air samples before GLSC analysis. The Tenax GC trap method enables TMA recovery only with a sensitivity of 0.0001 ppmv. Recovery obtained with 60/80 Carbopack B traps is practically zero.

  20. A Nanoporous Alumina Membrane Based Electrochemical Biosensor for Histamine Determination with Biofunctionalized Magnetic Nanoparticles Concentration and Signal Amplification

    PubMed Central

    Ye, Weiwei; Xu, Yifan; Zheng, Lihao; Zhang, Yu; Yang, Mo; Sun, Peilong

    2016-01-01

    Histamine is an indicator of food quality and indispensable in the efficient functioning of various physiological systems. Rapid and sensitive determination of histamine is urgently needed in food analysis and clinical diagnostics. Traditional histamine detection methods require qualified personnel, need complex operation processes, and are time-consuming. In this study, a biofunctionalized nanoporous alumina membrane based electrochemical biosensor with magnetic nanoparticles (MNPs) concentration and signal amplification was developed for histamine determination. Nanoporous alumina membranes were modified by anti-histamine antibody and integrated into polydimethylsiloxane (PDMS) chambers. The specific antibody modified MNPs were used to concentrate histamine from samples and transferred to the antibody modified nanoporous membrane. The MNPs conjugated to histamine were captured in the nanopores via specific reaction between histamine and anti-histamine antibody, resulting in a blocking effect that was amplified by MNPs in the nanopores. The blockage signals could be measured by electrochemical impedance spectroscopy across the nanoporous alumina membrane. The sensing platform had great sensitivity and the limit of detection (LOD) reached as low as 3 nM. This biosensor could be successfully applied for histamine determination in saury that was stored in frozen conditions for different hours, presenting a potentially novel, sensitive, and specific sensing system for food quality assessment and safety support. PMID:27782087

  1. Flow injection amperometric sensor with a carbon nanotube modified screen printed electrode for determination of hydroquinone.

    PubMed

    Upan, Jantima; Reanpang, Preeyaporn; Chailapakul, Orawon; Jakmunee, Jaroon

    2016-01-01

    Flow injection amperometric (FI-Amp) sensor was developed for sensitive and selective determination of hydroquinone. A simple screen printed carbon electrode (SPCE) was modified with various nanomaterials for improvement of sensitivity on the determination of quinone. As a result, the appropriate sensitivity is obtained from the SPCE modified with carbon nanotube (CNT) which indicated that CNT contributed to the transfer of electron to quinone. The reproducibility (n=9) and repeatability (n=111) of SPCE-CNT were obtained at 4.4% and 3.6%RSD, respectively. The SPCE-CNT electrode and enzymatic column were incorporated to the FI-Amp system to determine hydroquinone. Laccase was immobilized on silica gel using a cross-linking method by glutaraldehyde modification and then packed in the column. The laccase column has high efficiency for catalytic oxidation of hydroquinone to quinone, which further detects by amperometric detection. Parameters affecting response of the proposed sensor, i.e., pH, ionic strength, and temperature have been optimized. The proposed system provided a wide linear range between 1 and 50 µM with detection limit of 0.1 µM. Satisfactory recoveries in the range of 91.2-103.8% were obtained for the analysis of water sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Sensitivity of a phase-sensitive optical time-domain reflectometer with a semiconductor laser source

    NASA Astrophysics Data System (ADS)

    Alekseev, A. E.; Tezadov, Ya A.; Potapov, V. T.

    2018-06-01

    In the present paper we perform, for the first time, an analysis of the average sensitivity of a coherent phase-sensitive optical time-domain reflectometer (phase-OTDR) with a semiconductor laser source to external actions. The sensitivity of this OTDR can be defined in a conventional manner via average SNR at its output, which in turn is defined by the average useful signal power and the average intensity noise power in the OTDR spatial channels in the bandwidth defined by the OTDR sampling frequency. The average intensity noise power is considered in detail in a previous paper. In the current paper we examine the average useful signal power at the output of a phase-OTDR. The analysis of the average useful signal power of a phase-OTDR is based on the study of a fiber scattered-light interferometer (FSLI) which is treated as a constituent part of a phase- OTDR. In the analysis, one of the conventional phase-OTDR schemes with a rectangular dual-pulse probe signal is considered. The FSLI which corresponds to this OTDR scheme has two scattering fiber segments with additional time delay, introduced between backscattered fields. The average useful signal power and the resulting average SNR at the output of this FSLI are determined by the degree of coherence of the semiconductor laser source, the length of the scattering fiber segments, and by the additional time delay between the scattering fiber segments. The average useful signal power characteristic of the corresponding phase-OTDR is determined by analogous parameters: the source coherence, the time durations of the parts constituting the dual-pulse, and the time interval which separates these parts. In the paper an expression for the average useful signal power of a phase-OTDR is theoretically derived and experimentally verified. Based on the found average useful signal power of a phase-OTDR and the average intensity noise power, derived in the previous paper, the average SNR of a phase-OTDR is defined. Setting the average signal SNR to 1, at a defined spectral band the minimum detectable external action amplitude for our particular phase-OTDR setup is determined. We also derive a simple relation for the average useful signal power and the average SNR which results when making the assumption that the laser source coherence is high. The results of the paper can serve as the basis for further development of the concept of phase-OTDR sensitivity.

  3. Longitudinal sensitivity to change of MRI-based muscle cross-sectional area versus isometric strength analysis in osteoarthritic knees with and without structural progression: pilot data from the Osteoarthritis Initiative.

    PubMed

    Dannhauer, Torben; Sattler, Martina; Wirth, Wolfgang; Hunter, David J; Kwoh, C Kent; Eckstein, Felix

    2014-08-01

    Biomechanical measurement of muscle strength represents established technology in evaluating limb function. Yet, analysis of longitudinal change suffers from relatively large between-measurement variability. Here, we determine the sensitivity to change of magnetic resonance imaging (MRI)-based measurement of thigh muscle anatomical cross sectional areas (ACSAs) versus isometric strength in limbs with and without structural progressive knee osteoarthritis (KOA), with focus on the quadriceps. Of 625 "Osteoarthritis Initiative" participants with radiographic KOA, 20 had MRI cartilage and radiographic joint space width loss in the right knee isometric muscle strength measurement and axial T1-weighted spin-echo acquisitions of the thigh. Muscle ACSAs were determined from manual segmentation at 33% femoral length (distal to proximal). In progressor knees, the reduction in quadriceps ACSA between baseline and 2-year follow-up was -2.8 ± 7.9 % (standardized response mean [SRM] = -0.35), and it was -1.8 ± 6.8% (SRM = -0.26) in matched, non-progressive KOA controls. The decline in extensor strength was more variable than that in ACSAs, both in progressors (-3.9 ± 20%; SRM = -0.20) and in non-progressive controls (-4.5 ± 28%; SRM = -0.16). MRI-based analysis of quadriceps muscles ACSAs appears to be more sensitive to longitudinal change than isometric extensor strength and is suggestive of greater loss in limbs with structurally progressive KOA than in non-progressive controls.

  4. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants.

    PubMed

    Cuijpers, Vincent M J I; Jaroszewicz, Jacub; Anil, Sukumaran; Al Farraj Aldosari, Abdullah; Walboomers, X Frank; Jansen, John A

    2014-03-01

    The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. To determine spatial resolution and sensitivity, standardized reference samples containing standardized nano- and microspheres were prepared in polymer and ceramic matrices. Thereafter, 10 titanium-coated polymer dental implants (3.2 mm in Ø by 4 mm in length) were placed in the mandible of Beagle dogs. Both micro- and nano-CT, as well as histological analyses, were performed. The reference samples confirmed the high resolution of the nano-CT system, which was capable of revealing sub-micron structures embedded in radiodense matrices. The dog implantation study and subsequent statistical analysis showed equal values for bone area and bone-implant contact measurements between micro-CT and histology. However, because of the limited sample size and field of view, nano-CT was not rendering reliable data representative of the entire bone-implant specimen. Micro-CT analysis is an efficient tool to quantitate bone healing parameters at the bone-implant interface, especially when using titanium-coated PMMA implants. Nano-CT is not suitable for such quantification, but reveals complementary morphological information rivaling histology, yet with the advantage of a 3D visualization. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  5. Analysis of consumers' preferences and behavior with regard to horse meat using a structured survey questionnaire.

    PubMed

    Oh, Woon Yong; Lee, Ji Woong; Lee, Chong Eon; Ko, Moon Seok; Jeong, Jae Hong

    2009-12-01

    In this study, a structured survey questionnaire was used to determine consumers' preferences and behavior with regard to horse meat at a horse meat restaurant located in Jeju, Korea, from October 1 to December 24, 2005. The questionnaire employed in this study consisted of 20 questions designed to characterize six general attributes: horse meat sensory property, physical appearance, health condition, origin, price, and other attributes. Of the 1370 questionnaires distributed, 1126 completed questionnaires were retained based on the completeness of the answers, representing an 82.2% response rate. Two issues were investigated that might facilitate the search for ways to improve horse meat production and marketing programs in Korea. The first step was to determine certain important factors, called principal components, which enabled the researchers to understand the needs of horse meat consumers via principal component analysis. The second step was to define consumer segments with regard to their preferences for horse meat, which was accomplished via cluster analysis. The results of the current study showed that health condition, price, origin, and leanness were the most critical physical attributes affecting the preferences of horse meat consumers. Four segments of consumers, with different demands for horse meat attributes, were identified: origin-sensitive consumers, price-sensitive consumers, quality and safety-sensitive consumers, and non-specific consumers. Significant differences existed among segments of consumers in terms of age, nature of work, frequency of consumption, and general level of acceptability of horse meat.

  6. Trace element analysis of synthetic mono- and poly-crystalline CaF 2 by ultraviolet laser ablation inductively coupled plasma mass spectrometry at 266 and 193 nm

    NASA Astrophysics Data System (ADS)

    Koch, J.; Feldmann, I.; Hattendorf, B.; Günther, D.; Engel, U.; Jakubowski, N.; Bolshov, M.; Niemax, K.; Hergenröder, R.

    2002-06-01

    The analytical figures of merit for ultraviolet laser ablation-inductively coupled plasma mass spectrometry (UV-LA-ICP-MS) at 266 nm with respect to the trace element analysis of high-purity, UV-transmitting alkaline earth halides are investigated and discussed. Ablation threshold energy density values and ablation rates for mono- and poly-crystalline CaF 2 samples were determined. Furthermore, Pb-, Rb-, Sr-, Ba- and Yb-specific analysis was performed. For these purposes, a pulsed Nd:YAG laser operated at the fourth harmonic of the fundamental wavelength (λ=266 nm) and a double-focusing sector field ICP-MS detector were employed. Depending on the background noise and isotope-specific sensitivity, the detection limits typically varied from 0.7 ng/g for Sr to 7 ng/g in the case of Pb. The concentrations were determined using a glass standard reference material (SRM NIST612). In order to demonstrate the sensitivity of the arrangement described, comparative measurements by means of a commercial ablation system consisting of an ArF excimer laser (λ=193 nm) and a quadrupole-type ICP-MS (ICP-QMS) instrument were carried out. The accuracy of both analyses was in good agreement, whereas ablation at 266 nm and detection using sector-field ICP-MS led to a sensitivity that was one order of magnitude above that obtained at 193 nm with ICP-QMS.

  7. Cytochrome P450-mediated warfarin metabolic ability is not a critical determinant of warfarin sensitivity in avian species: In vitro assays in several birds and in vivo assays in chicken.

    PubMed

    Watanabe, Kensuke P; Kawata, Minami; Ikenaka, Yoshinori; Nakayama, Shouta M M; Ishii, Chihiro; Darwish, Wageh Sobhi; Saengtienchai, Aksorn; Mizukawa, Hazuki; Ishizuka, Mayumi

    2015-10-01

    Coumarin-derivative anticoagulant rodenticides used for rodent control are posing a serious risk to wild bird populations. For warfarin, a classic coumarin derivative, chickens have a high median lethal dose (LD50), whereas mammalian species generally have much lower LD50. Large interspecies differences in sensitivity to warfarin are to be expected. The authors previously reported substantial differences in warfarin metabolism among avian species; however, the actual in vivo pharmacokinetics have yet to be elucidated, even in the chicken. In the present study, the authors sought to provide an in-depth characterization of warfarin metabolism in birds using in vivo and in vitro approaches. A kinetic analysis of warfarin metabolism was performed using liver microsomes of 4 avian species, and the metabolic abilities of the chicken and crow were much higher in comparison with those of the mallard and ostrich. Analysis of in vivo metabolites from chickens showed that excretions predominantly consisted of 4'-hydroxywarfarin, which was consistent with the in vitro results. Pharmacokinetic analysis suggested that chickens have an unexpectedly long half-life despite showing high metabolic ability in vitro. The results suggest that the half-life of warfarin in other bird species could be longer than that in the chicken and that warfarin metabolism may not be a critical determinant of species differences with respect to warfarin sensitivity. © 2015 SETAC.

  8. Approaching the Limit in Atomic Spectrochemical Analysis.

    ERIC Educational Resources Information Center

    Hieftje, Gary M.

    1982-01-01

    To assess the ability of current analytical methods to approach the single-atom detection level, theoretical and experimentally determined detection levels are presented for several chemical elements. A comparison of these methods shows that the most sensitive atomic spectrochemical technique currently available is based on emission from…

  9. Investigating and understanding fouling in a planar setup using ultrasonic methods.

    PubMed

    Wallhäusser, E; Hussein, M A; Becker, T

    2012-09-01

    Fouling is an unwanted deposit on heat transfer surfaces and occurs regularly in foodstuff heat exchangers. Fouling causes high costs because cleaning of heat exchangers has to be carried out and cleaning success cannot easily be monitored. Thus, used cleaning cycles in foodstuff industry are usually too long leading to high costs. In this paper, a setup is described with which it is possible, first, to produce dairy protein fouling similar to the one found in industrial heat exchangers and, second, to detect the presence and absence of such fouling using an ultrasonic based measuring method. The developed setup resembles a planar heat exchanger in which fouling can be made and cleaned reproducible. Fouling presence, absence, and cleaning progress can be monitored by using an ultrasonic detection unit. The setup is described theoretically based on electrical and mechanical lumped circuits to derive the wave equation and the transfer function to perform a sensitivity analysis. Sensitivity analysis was done to determine influencing quantities and showed that fouling is measurable. Also, first experimental results are compared with results from sensitivity analysis.

  10. Molecular and Proteomic Analysis of Levofloxacin and Metronidazole Resistant Helicobacter pylori.

    PubMed

    Hanafi, Aimi; Lee, Woon Ching; Loke, Mun Fai; Teh, Xinsheng; Shaari, Ain; Dinarvand, Mojdeh; Lehours, Philippe; Mégraud, Francis; Leow, Alex Hwong Ruey; Vadivelu, Jamuna; Goh, Khean Lee

    2016-01-01

    Antibiotic resistance in bacteria incurs fitness cost, but compensatory mechanisms may ameliorate the cost and sustain the resistance even under antibiotics-free conditions. The aim of this study was to determine compensatory mechanisms of antibiotic resistance in H. pylori . Five strains of levofloxacin-sensitive H. pylori were induced in vitro to develop resistance. In addition, four pairs of metronidazole-sensitive and -resistant H. pylori strains were isolated from patients carrying dual H. pylori populations that consist of both sensitive and resistant phenotypes. Growth rate, virulence and biofilm-forming ability of the sensitive and resistant strains were compared to determine effects of compensatory response. Proteome profiles of paired sensitive and resistant strains were analyzed by liquid chromatography/mass spectrophotometry (LC/MS). Although there were no significant differences in growth rate between sensitive and resistant pairs, bacterial virulence (in terms of abilities to induce apoptosis and form biofilm) differs from pair to pair. These findings demonstrate the complex and strain-specific phenotypic changes in compensation for antibiotics resistance. Compensation for in vitro induced levofloxacin resistance involving mutations of gyrA and gyrB was functionally random. Furthermore, higher protein translation and non-functional protein degradation capabilities in naturally-occuring dual population metronidazole sensitive-resistant strains may be a possible alternative mechanism underlying resistance to metronidazole without mutations in rdxA and frxA . This may explain the lack of mutations in target genes in ~10% of metronidazole resistant strains.

  11. Molecular and Proteomic Analysis of Levofloxacin and Metronidazole Resistant Helicobacter pylori

    PubMed Central

    Hanafi, Aimi; Lee, Woon Ching; Loke, Mun Fai; Teh, Xinsheng; Shaari, Ain; Dinarvand, Mojdeh; Lehours, Philippe; Mégraud, Francis; Leow, Alex Hwong Ruey; Vadivelu, Jamuna; Goh, Khean Lee

    2016-01-01

    Antibiotic resistance in bacteria incurs fitness cost, but compensatory mechanisms may ameliorate the cost and sustain the resistance even under antibiotics-free conditions. The aim of this study was to determine compensatory mechanisms of antibiotic resistance in H. pylori. Five strains of levofloxacin-sensitive H. pylori were induced in vitro to develop resistance. In addition, four pairs of metronidazole-sensitive and -resistant H. pylori strains were isolated from patients carrying dual H. pylori populations that consist of both sensitive and resistant phenotypes. Growth rate, virulence and biofilm-forming ability of the sensitive and resistant strains were compared to determine effects of compensatory response. Proteome profiles of paired sensitive and resistant strains were analyzed by liquid chromatography/mass spectrophotometry (LC/MS). Although there were no significant differences in growth rate between sensitive and resistant pairs, bacterial virulence (in terms of abilities to induce apoptosis and form biofilm) differs from pair to pair. These findings demonstrate the complex and strain-specific phenotypic changes in compensation for antibiotics resistance. Compensation for in vitro induced levofloxacin resistance involving mutations of gyrA and gyrB was functionally random. Furthermore, higher protein translation and non-functional protein degradation capabilities in naturally-occuring dual population metronidazole sensitive-resistant strains may be a possible alternative mechanism underlying resistance to metronidazole without mutations in rdxA and frxA. This may explain the lack of mutations in target genes in ~10% of metronidazole resistant strains. PMID:28018334

  12. Mitochondrial fission determines cisplatin sensitivity in tongue squamous cell carcinoma through the BRCA1–miR-593-5p–MFF axis

    PubMed Central

    Chen, Weixiong; Chen, Weiliang; Tang, Qionglan; Wang, Youyuan; Su, Yuxiong; Jin, Shaowen; Zhang, Daming; Zhong, Jianglong; Li, Yilin; Wen, Bin; Zhang, Zhang; Yang, Pu; Zhou, Bin; Liang, Qixiang; Yu, Xing; Zhu, Yinghua; Hu, Pengnan; Chu, Junjun; Huang, Wei; Feng, Yuhuan; Peng, Hongzhuang; Huang, Qihong; Song, Erwei; Li, Jinsong

    2015-01-01

    Cisplatin has been widely employed as a cornerstone chemotherapy treatment for a wide spectrum of solid neoplasms; increasing tumor responsiveness to cisplatin has been a topic of interest for the past 30 years. Strong evidence has indicated that mitochondrial fission participates in the regulation of apoptosis in many diseases; however, whether mitochondrial fission regulates cisplatin sensitivity remains poorly understood. Here, we show that MFF mediated mitochondrial fission and apoptosis in tongue squamous cell carcinoma (TSCC) cells after cisplatin treatment and that miR-593-5p was downregulated in this process. miR-593-5p attenuated mitochondrial fission and cisplatin sensitivity by targeting the 3′ untranslated region sequence of MFF and inhibiting its translation. In exploring the underlying mechanism of miR-593-5p downregulation, we observed that BRCA1 transactivated miR-593-5p expression and attenuated cisplatin sensitivity in vitro. The BRCA1-miR-593-5p-MFF axis also affected cisplatin sensitivity in vivo. Importantly, in a retrospective analysis of multiple centers, we further found that the BRCA1-miR-593-5p-MFF axis was significantly associated with cisplatin sensitivity and the survival of patients with TSCC. Together, our data reveal a model for mitochondrial fission regulation at the transcriptional and post-transcriptional levels; we also reveal a new pathway for BRCA1 in determining cisplatin sensitivity through the mitochondrial fission program. PMID:25912308

  13. The relevance of the slope for concentration-effect relations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schobben, H.P.M.; Smit, M.; Schobben, J.H.M.

    1995-12-31

    Risk analysis is mostly based on a comparison of one value for the exposure to a chemical (PEC) and one value for the sensitivity of biota (NEC). This method enables the determination of an effect to be expected, but it is not possible to quantify the magnitude of that effect. Moreover, it is impossible to estimate the effect of a combination of chemicals. Therefore, it is necessary to use a mathematical function to describe the relation between a concentration and the subsequent effect. These relations are typically based on a log normal or log logistic distribution of the sensitivity ofmore » individuals of a species. This distribution is characterized by the median sensitivity (EC{sub 50}) and the variation between the sensitivity of individuals (being a measure for the slope of the relation). Presently the attention is focused on the median, while the slope might be even more important. Relevant exposure concentrations are typically in the range which are found in the left tail of the sensitivity distribution. In this study the slope was determined for 250 chemical-species combinations. The data were derived from original experiments and from literature. The slope is highly dependent on the exposure time; the shorter the exposure time the steeper the slope. If data for a standard exposure time [96 hours] are considered, the total variation in slope can partly be explained by the groups of organisms and chemicals. The slope for heavy metals tends to be less steep as compared to the slope of narcotic organic compounds. The slope for fish and molluscs is steeper than for crustaceans. The results of this study are presently applied in a number of risk analysis studies.« less

  14. Algorithm for automatic analysis of electro-oculographic data

    PubMed Central

    2013-01-01

    Background Large amounts of electro-oculographic (EOG) data, recorded during electroencephalographic (EEG) measurements, go underutilized. We present an automatic, auto-calibrating algorithm that allows efficient analysis of such data sets. Methods The auto-calibration is based on automatic threshold value estimation. Amplitude threshold values for saccades and blinks are determined based on features in the recorded signal. The performance of the developed algorithm was tested by analyzing 4854 saccades and 213 blinks recorded in two different conditions: a task where the eye movements were controlled (saccade task) and a task with free viewing (multitask). The results were compared with results from a video-oculography (VOG) device and manually scored blinks. Results The algorithm achieved 93% detection sensitivity for blinks with 4% false positive rate. The detection sensitivity for horizontal saccades was between 98% and 100%, and for oblique saccades between 95% and 100%. The classification sensitivity for horizontal and large oblique saccades (10 deg) was larger than 89%, and for vertical saccades larger than 82%. The duration and peak velocities of the detected horizontal saccades were similar to those in the literature. In the multitask measurement the detection sensitivity for saccades was 97% with a 6% false positive rate. Conclusion The developed algorithm enables reliable analysis of EOG data recorded both during EEG and as a separate metrics. PMID:24160372

  15. Algorithm for automatic analysis of electro-oculographic data.

    PubMed

    Pettersson, Kati; Jagadeesan, Sharman; Lukander, Kristian; Henelius, Andreas; Haeggström, Edward; Müller, Kiti

    2013-10-25

    Large amounts of electro-oculographic (EOG) data, recorded during electroencephalographic (EEG) measurements, go underutilized. We present an automatic, auto-calibrating algorithm that allows efficient analysis of such data sets. The auto-calibration is based on automatic threshold value estimation. Amplitude threshold values for saccades and blinks are determined based on features in the recorded signal. The performance of the developed algorithm was tested by analyzing 4854 saccades and 213 blinks recorded in two different conditions: a task where the eye movements were controlled (saccade task) and a task with free viewing (multitask). The results were compared with results from a video-oculography (VOG) device and manually scored blinks. The algorithm achieved 93% detection sensitivity for blinks with 4% false positive rate. The detection sensitivity for horizontal saccades was between 98% and 100%, and for oblique saccades between 95% and 100%. The classification sensitivity for horizontal and large oblique saccades (10 deg) was larger than 89%, and for vertical saccades larger than 82%. The duration and peak velocities of the detected horizontal saccades were similar to those in the literature. In the multitask measurement the detection sensitivity for saccades was 97% with a 6% false positive rate. The developed algorithm enables reliable analysis of EOG data recorded both during EEG and as a separate metrics.

  16. Review-of-systems questionnaire as a predictive tool for psychogenic nonepileptic seizures.

    PubMed

    Robles, Liliana; Chiang, Sharon; Haneef, Zulfi

    2015-04-01

    Patients with refractory epilepsy undergo video-electroencephalography for seizure characterization, among whom approximately 10-30% will be discharged with the diagnosis of psychogenic nonepileptic seizures (PNESs). Clinical PNES predictors have been described but in general are not sensitive or specific. We evaluated whether multiple complaints in a routine review-of-system (ROS) questionnaire could serve as a sensitive and specific marker of PNESs. We performed a retrospective analysis of a standardized ROS questionnaire completed by patients with definite PNESs and epileptic seizures (ESs) diagnosed in our adult epilepsy monitoring unit. A multivariate analysis of covariance (MANCOVA) was used to determine whether groups with PNES and ES differed with respect to the percentage of complaints in the ROS questionnaire. Tenfold cross-validation was used to evaluate the predictive error of a logistic regression classifier for PNES status based on the percentage of positive complaints in the ROS questionnaire. A total of 44 patients were included for analysis. Patients with PNESs had a significantly higher number of complaints in the ROS questionnaire compared to patients with epilepsy. A threshold of 17% positive complaints achieved a 78% specificity and 85% sensitivity for discriminating between PNESs and ESs. We conclude that the routine ROS questionnaire may be a sensitive and specific predictive tool for discriminating between PNESs and ESs. Published by Elsevier Inc.

  17. Sedentary Behaviour Profiling of Office Workers: A Sensitivity Analysis of Sedentary Cut-Points

    PubMed Central

    Boerema, Simone T.; Essink, Gerard B.; Tönis, Thijs M.; van Velsen, Lex; Hermens, Hermie J.

    2015-01-01

    Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points. PMID:26712758

  18. Generic Hypersonic Inlet Module Analysis

    NASA Technical Reports Server (NTRS)

    Cockrell, Chares E., Jr.; Huebner, Lawrence D.

    2004-01-01

    A computational study associated with an internal inlet drag analysis was performed for a generic hypersonic inlet module. The purpose of this study was to determine the feasibility of computing the internal drag force for a generic scramjet engine module using computational methods. The computational study consisted of obtaining two-dimensional (2D) and three-dimensional (3D) computational fluid dynamics (CFD) solutions using the Euler and parabolized Navier-Stokes (PNS) equations. The solution accuracy was assessed by comparisons with experimental pitot pressure data. The CFD analysis indicates that the 3D PNS solutions show the best agreement with experimental pitot pressure data. The internal inlet drag analysis consisted of obtaining drag force predictions based on experimental data and 3D CFD solutions. A comparative assessment of each of the drag prediction methods is made and the sensitivity of CFD drag values to computational procedures is documented. The analysis indicates that the CFD drag predictions are highly sensitive to the computational procedure used.

  19. [RATIONAL ASPECTS OF BACTERIOPHAGES USE].

    PubMed

    Vakarina, A A; Kataeva, L V; Karpukhina, N F

    2015-01-01

    Analysis of existing aspects of bacteriophage use and study features of their lytic activity by using various techniques. Effect of monophages and associated bacteriophages (staphylococci, piopolyvalent and piocombined, intestiphage, pneumonia klebsiella and polyvalent klebsiella produced by "Microgen") was studied with 380 strains of Staphylococcus aureus and 279 cultures of Klebsiella pneumoniae in liquid and solid nutrient media. From patients with intestinal disorder, sensitivity was analyzed to 184 strains of Salmonella genus bacteria 18 serological variants to salmonella bacteriophages, 137 strains of Escherichia coli (lactose-negative, hemolytic), as well as some members of OKA groups (21 serovars) to coli-proteic and piopolyvalent bacteriophages. Lytic ability of the piobacteriophage against Klebsiella and Proteus genus bacteria was determined. Staphylococcus aureus was sensitive to staphylococcus bacteriophage in 71.6% of cases and to piobacteriophage--in 86.15% of cases. A 100% lytic ability of salmonella bacteriophage against Salmonella spp. was established. Sensitivity of E. coli of various serogroups to coli-proteic and piobacteriophage was 66 - 100%. Klebsiella, Proteus genus bacteria were sensitive to piobacteriophage in only 35% and 43.15% of cases, respectively. A more rational use of bacteriophages is necessary: development of a technique, evaluation of sensitivity of bacteria to bacteriophage, introduction of corrections into their production (expansion of bacteriophage spectra, determination and indication of their concentration in accompanying documents).

  20. Cost-effectiveness analysis of the most common orthopaedic surgery procedures: knee arthroscopy and knee anterior cruciate ligament reconstruction.

    PubMed

    Lubowitz, James H; Appleby, David

    2011-10-01

    The purpose of this study was to determine the cost-effectiveness of knee arthroscopy and anterior cruciate ligament (ACL) reconstruction. Retrospective analysis of prospectively collected data from a single-surgeon, institutional review board-approved outcomes registry included 2 cohorts: surgically treated knee arthroscopy and ACL reconstruction patients. Our outcome measure is cost-effectiveness (cost of a quality-adjusted life-year [QALY]). The QALY is calculated by multiplying difference in health-related quality of life, before and after treatment, by life expectancy. Health-related quality of life is measured by use of the Quality of Well-Being scale, which has been validated for cost-effectiveness analysis. Costs are facility charges per the facility cost-to-charges ratio plus surgeon fee. Sensitivity analyses are performed to determine the effect of variations in costs or outcomes. There were 93 knee arthroscopy and 35 ACL reconstruction patients included at a mean follow-up of 2.1 years. Cost per QALY was $5,783 for arthroscopy and $10,326 for ACL reconstruction (2009 US dollars). Sensitivity analysis shows that our results are robust (relatively insensitive) to variations in costs or outcomes. Knee arthroscopy and knee ACL reconstruction are very cost-effective. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations.

    PubMed

    Hassan, Wafaa S; El-Henawee, Magda M; Gouda, Ayman A

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at lambda(max) 470nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70microgmL(-1) for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  2. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations

    NASA Astrophysics Data System (ADS)

    Hassan, Wafaa S.; El-Henawee, Magda M.; Gouda, Ayman A.

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at λmax 470 nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426 nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70 μg mL -1 for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  3. Clinical color vision testing and correlation with visual function.

    PubMed

    Zhao, Jiawei; Davé, Sarita B; Wang, Jiangxia; Subramanian, Prem S

    2015-09-01

    To determine if Hardy-Rand-Rittler (H-R-R) and Ishihara testing are accurate estimates of color vision in subjects with acquired visual dysfunction. Assessment of diagnostic tools. Twenty-two subjects with optic neuropathy (aged 18-65) and 18 control subjects were recruited prospectively from an outpatient clinic. Individuals with visual acuity (VA) <20/200 or with congenital color blindness were excluded. All subjects underwent a comprehensive eye examination including VA, color vision, and contrast sensitivity testing. Color vision was assessed using H-R-R and Ishihara plates and Farnsworth D-15 (D-15) discs. D-15 is the accepted standard for detecting and classifying color vision deficits. Contrast sensitivity was measured using Pelli-Robson contrast sensitivity charts. No relationship was found between H-R-R and D-15 scores (P = .477). H-R-R score and contrast sensitivity were positively correlated (P = .003). On multivariate analysis, contrast sensitivity (β = 8.61, P < .001) and VA (β = 2.01, P = .022) both showed association with H-R-R scores. Similar to H-R-R, Ishihara score did not correlate with D-15 score (P = .973), but on multivariate analysis was related to contrast sensitivity (β = 8.69, P < .001). H-R-R and Ishihara scores had an equivalent relationship with contrast sensitivity (P = .069). Neither H-R-R nor Ishihara testing appears to assess color identification in patients with optic neuropathy. Both H-R-R and Ishihara testing are correlated with contrast sensitivity, and these tests may be useful clinical surrogates for contrast sensitivity testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Global water cycle

    NASA Technical Reports Server (NTRS)

    Robertson, Franklin R.; Christy, John R.; Goodman, Steven J.; Miller, Tim L.; Fitzjarrald, Dan; Lapenta, Bill; Wang, Shouping

    1991-01-01

    The primary objective is to determine the scope and interactions of the global water cycle with all components of the Earth system and to understand how it stimulates and regulates changes on both global and regional scales. The following subject areas are covered: (1) water vapor variability; (2) multi-phase water analysis; (3) diabatic heating; (4) MSU (Microwave Sounding Unit) temperature analysis; (5) Optimal precipitation and streamflow analysis; (6) CCM (Community Climate Model) hydrological cycle; (7) CCM1 climate sensitivity to lower boundary forcing; and (8) mesoscale modeling of atmosphere/surface interaction.

  5. [Validation of the abbreviated Zarit scales for measuring burden syndrome in the primary caregiver of an elderly patient].

    PubMed

    Vélez Lopera, Johana María; Berbesí Fernández, Dedsy; Cardona Arango, Doris; Segura Cardona, Angela; Ordóñez Molina, Jaime

    2012-07-01

    To determine which abbreviated Zarit Scale (ZS) better evaluates the burden of the caregiver of an elderly patient in Medellin, Colombia. Validation study. Primary Care setting in the city of Medellin. Primary caregiver of dependent elderly patients over 65 years old. Sensitivity, specificity, positive predictive value, and negative predictive value for the different abbreviated Zarit scales, plus performing a reliability analysis using the Cronbach Alpha coefficient. The abbreviated scales obtained a sensitivity of between 36.84 and 81.58%, specificity between 95.99 and 100%, positive predictive values between 71.05 and 100%, and negative predictive values of between 91.64 and 97.42%. The scale that better determined caregiver burden in Primary Care was the Bedard Screening scale, with a sensitivity of 81.58%, a specificity of 96.35% and positive and negative predictive values of 75.61% and 97.42%, respectively. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  6. Sensitive determination of endogenous hydroxyl radical in live cell by a BODIPY based fluorescent probe.

    PubMed

    Lei, Kepeng; Sun, Mingtai; Du, Libo; Zhang, Xiaojie; Yu, Huan; Wang, Suhua; Hayat, Tasawar; Alsaedi, Ahmed

    2017-08-01

    The sensitive and selective fluorescence probe for hydroxyl radical analysis is of significance because hydroxyl radical plays key roles in many physiological and pathological processes. In this work, a novel organic fluorescence molecular probe OHP for hydroxyl radical is synthesized by a two-step route. The probe employs 4-bora-3a,4a-diaza-s-indacene (difluoroboron dipyrromethene, BODIPY) as the fluorophore and possesses relatively high fluorescence quantum yields (77.14%). Hydroxyl radical can rapidly react with the probe and quench the fluorescence in a good linear relationship (R 2 =0.9967). The limit of detection is determined to be as low as 11nM. In addition, it has been demonstrated that the probe has a good stability against pH and light illumination, low cytotoxicity and high biocompatibility. Cell culture experimental results show that the probe OHP is sensitive and selective for imaging and tracking endogenous hydroxyl radical in live cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Sensitivity and specificity of Addenbrooke's Cognitive Examination, Mattis Dementia Rating Scale, Frontal Assessment Battery and Mini Mental State Examination for diagnosing dementia in Parkinson's disease.

    PubMed

    Kaszás, B; Kovács, N; Balás, I; Kállai, J; Aschermann, Z; Kerekes, Z; Komoly, S; Nagy, F; Janszky, J; Lucza, T; Karádi, K

    2012-06-01

    Among the non-motor features of Parkinson's disease (PD), cognitive impairment is one of the most troublesome problems. Highly sensitive and specific screening instruments for detecting dementia in PD (PDD) are required in the clinical practice. In our study we evaluated the sensitivity and specificity of different neuropsychological tests (Addenbrooke's Cognitive Examination, ACE; Frontal Assessment Battery, FAB and Mattis Dementia Rating Scale, MDRS) in 73 Parkinson's disease patients without depression. By receiver operating characteristic curve analysis, these screening instruments were tested against the recently established clinical diagnostic criteria of PDD. Best cut-off score for ACE to identify PDD was 80 points (sensitivity = 74.0%, specificity = 78.1%). For FAB the most optimal cut-off value was 12 points (sensitivity = 66.3%, specificity = 72.2%); whereas for MDRS it was 125 points (sensitivity = 89.8%, specificity = 98.3%). Among the examined test batteries, MDRS had the best clinicometric profile for detecting PDD. Although the types of applied screening instruments might differ from movement disorder clinic to clinic within a country, determination of the most specific and sensitive test for the given population remains to be an important task. Our results demonstrated that the specificity and sensitivity of MDRS was better than those of ACE, FAB and MMSE in Hungary. However, further studies with larger sample size and more uniform criteria for participation are required to determine the most suitable screening instrument for cognitive impairment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Detection of somatic mutations by high-resolution DNA melting (HRM) analysis in multiple cancers.

    PubMed

    Gonzalez-Bosquet, Jesus; Calcei, Jacob; Wei, Jun S; Garcia-Closas, Montserrat; Sherman, Mark E; Hewitt, Stephen; Vockley, Joseph; Lissowska, Jolanta; Yang, Hannah P; Khan, Javed; Chanock, Stephen

    2011-01-17

    Identification of somatic mutations in cancer is a major goal for understanding and monitoring the events related to cancer initiation and progression. High resolution melting (HRM) curve analysis represents a fast, post-PCR high-throughput method for scanning somatic sequence alterations in target genes. The aim of this study was to assess the sensitivity and specificity of HRM analysis for tumor mutation screening in a range of tumor samples, which included 216 frozen pediatric small rounded blue-cell tumors as well as 180 paraffin-embedded tumors from breast, endometrial and ovarian cancers (60 of each). HRM analysis was performed in exons of the following candidate genes known to harbor established commonly observed mutations: PIK3CA, ERBB2, KRAS, TP53, EGFR, BRAF, GATA3, and FGFR3. Bi-directional sequencing analysis was used to determine the accuracy of the HRM analysis. For the 39 mutations observed in frozen samples, the sensitivity and specificity of HRM analysis were 97% and 87%, respectively. There were 67 mutation/variants in the paraffin-embedded samples, and the sensitivity and specificity for the HRM analysis were 88% and 80%, respectively. Paraffin-embedded samples require higher quantity of purified DNA for high performance. In summary, HRM analysis is a promising moderate-throughput screening test for mutations among known candidate genomic regions. Although the overall accuracy appears to be better in frozen specimens, somatic alterations were detected in DNA extracted from paraffin-embedded samples.

  9. Detection of Somatic Mutations by High-Resolution DNA Melting (HRM) Analysis in Multiple Cancers

    PubMed Central

    Gonzalez-Bosquet, Jesus; Calcei, Jacob; Wei, Jun S.; Garcia-Closas, Montserrat; Sherman, Mark E.; Hewitt, Stephen; Vockley, Joseph; Lissowska, Jolanta; Yang, Hannah P.; Khan, Javed; Chanock, Stephen

    2011-01-01

    Identification of somatic mutations in cancer is a major goal for understanding and monitoring the events related to cancer initiation and progression. High resolution melting (HRM) curve analysis represents a fast, post-PCR high-throughput method for scanning somatic sequence alterations in target genes. The aim of this study was to assess the sensitivity and specificity of HRM analysis for tumor mutation screening in a range of tumor samples, which included 216 frozen pediatric small rounded blue-cell tumors as well as 180 paraffin-embedded tumors from breast, endometrial and ovarian cancers (60 of each). HRM analysis was performed in exons of the following candidate genes known to harbor established commonly observed mutations: PIK3CA, ERBB2, KRAS, TP53, EGFR, BRAF, GATA3, and FGFR3. Bi-directional sequencing analysis was used to determine the accuracy of the HRM analysis. For the 39 mutations observed in frozen samples, the sensitivity and specificity of HRM analysis were 97% and 87%, respectively. There were 67 mutation/variants in the paraffin-embedded samples, and the sensitivity and specificity for the HRM analysis were 88% and 80%, respectively. Paraffin-embedded samples require higher quantity of purified DNA for high performance. In summary, HRM analysis is a promising moderate-throughput screening test for mutations among known candidate genomic regions. Although the overall accuracy appears to be better in frozen specimens, somatic alterations were detected in DNA extracted from paraffin-embedded samples. PMID:21264207

  10. BAD phosphorylation determines ovarian cancer chemo-sensitivity and patient survival

    PubMed Central

    Marchion, Douglas C.; Cottrill, Hope M.; Xiong, Yin; Chen, Ning; Bicaku, Elona; Fulp, William J.; Bansal, Nisha; Chon, Hye Sook; Stickles, Xiaomang B.; Kamath, Siddharth G.; Hakam, Ardeshir; Li, Lihua; Su, Dan; Moreno, Carolina; Judson, Patricia L.; Berchuck, Andrew; Wenham, Robert M.; Apte, Sachin M.; Gonzalez-Bosquet, Jesus; Bloom, Gregory C.; Eschrich, Steven A.; Sebti, Said; Chen, Dung-Tsa; Lancaster, Johnathan M.

    2011-01-01

    Purpose Despite initial sensitivity to chemotherapy, ovarian cancers (OVCA) often develop drug-resistance, which limits patient survival. Using specimens and/or genomic data from 289 patients and a panel of cancer cell lines, we explored genome-wide expression changes that underlie the evolution of OVCA chemo-resistance and characterized the BCL2 antagonist of cell death (BAD) apoptosis pathway as a determinant of chemo-sensitivity and patient survival. Experimental Design Serial OVCA cell cisplatin treatments were performed in parallel with measurements of genome-wide expression changes. Pathway analysis was performed on genes associated with increasing cisplatin-resistance (EC50). BAD-pathway expression and BAD-protein phosphorylation were evaluated in patient samples and cell lines as determinants of chemo-sensitivity and/or clinical outcome and as therapeutic targets. Results Induced in vitro OVCA cisplatin-resistance was associated with BAD-pathway expression (P < 0.001). In OVCA cell lines and primary specimens, BAD-protein phosphorylation was associated with platinum-resistance (n = 147, P < 0.0001) and also with overall patient survival (n = 134, P = 0.0007). Targeted modulation of BAD-phosphorylation levels influenced cisplatin sensitivity. A 47-gene BAD-pathway score was associated with in vitro phosphorylated-BAD levels and with survival in 142 patients with advanced-stage (III/IV) serous OVCA. Integration of BAD-phosphorylation or BAD-pathway score with OVCA surgical cytoreductive status was significantly associated with overall survival by log-rank test (P = 0.004 and <0.0001, respectively). Conclusion The BAD apoptosis pathway influences OVCA chemo-sensitivity and overall survival, likely via modulation of BAD-phosphorylation. The pathway has clinical relevance as a biomarker of therapeutic response, patient survival, and as a promising therapeutic target. PMID:21849418

  11. A simple and sensitive determination of histamine and N tau-methylhistamine in biological fluids by high-performance liquid chromatography with electrochemical detection.

    PubMed

    Houdi, A A; Crooks, P A; Van Loon, G R; Schubert, C A

    1987-05-01

    The determination of picomolar levels of histamine and its major metabolite, N tau-methylhistamine, in biological fluids was achieved using reversed-phase liquid chromatography coupled with electrochemical detection. A simple sample purification procedure for blood and urine samples was carried out prior to analysis using an Amberlite CG-50 cation-exchange resin, which afforded an excellent recovery of both compounds.

  12. A determination of the fragmentation functions of u-quarks into charged pions

    NASA Astrophysics Data System (ADS)

    Aubert, J. J.; Bassompierre, G.; Becks, K. H.; Benchouk, C.; Best, C.; Böhm, E.; De Bouard, X.; Brasse, F. W.; Broll, C.; Brown, S.; Carr, J.; Clifft, R.; Cobb, J. H.; Coignet, G.; Combley, F.; Court, G. R.; D'Agostini, G.; Dau, W. D.; Davies, J. K.; Déclais, Y.; Dosselli, U.; Drees, J.; Edwards, A.; Edwards, M.; Favier, J.; Ferrero, M. I.; Flauger, W.; Forsbach, H.; Gabathuler, E.; Gamet, R.; Gayler, J.; Gerhardt, V.; Gössling, C.; Haas, J.; Hamacher, K.; Hayman, P.; Henckes, M.; Korbel, V.; Korzen, B.; Landgraf, U.; Leenen, M.; Maire, M.; Mohr, W.; Montgomery, H. E.; Moser, K.; Mount, R. P.; Nagy, E.; Nassalski, J.; Norton, P. R.; McNicholas, J.; Osborne, A. M.; Payre, P.; Peroni, C.; Peschel, H.; Pessard, H.; Pietrzyk, U.; Rith, K.; Schneegans, M.; Schneider, A.; Sloan, T.; Stier, H. E.; Stockhausen, W.; Thénard, J. M.; Thompson, J. C.; Urban, L.; Villers, M.; Wahlen, H.; Whalley, M.; Williams, D.; Williams, W. S. C.; Williamson, J.; Wimpenny, S. J.; European Muon Collaboration (EMC)

    1985-10-01

    The fragmentation functions of u-quarks into positive and negative pions are determined from an analysis of identified pions produced in deep inelastic muon-deuterium scattering. The method adopted is not sensitive to the knowledge of the primary quark distribution functions. The fragmentation of u quarks to positive pions is found to fall less steeply in z than that to negative pions as expected in the quark parton model.

  13. Pain sensitivity mediates the relationship between stress and headache intensity in chronic tension-type headache

    PubMed Central

    Cathcart, Stuart; Bhullar, Navjot; Immink, Maarten; Della Vedova, Chris; Hayball, John

    2012-01-01

    BACKGROUND: A central model for chronic tension-type headache (CTH) posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. The prediction from this model that pain sensitivity mediates the relationship between stress and headache activity has not yet been examined. OBJECTIVE: To determine whether pain sensitivity mediates the relationship between stress and prospective headache activity in CTH sufferers. METHOD: Self-reported stress, pain sensitivity and prospective headache activity were measured in 53 CTH sufferers recruited from the general population. Pain sensitivity was modelled as a mediator between stress and headache activity, and tested using a nonparametric bootstrap analysis. RESULTS: Pain sensitivity significantly mediated the relationship between stress and headache intensity. CONCLUSIONS: The results of the present study support the central model for CTH, which posits that stress contributes to headache, in part, by aggravating existing hyperalgesia in CTH sufferers. Implications for the mechanisms and treatment of CTH are discussed. PMID:23248808

  14. Design and characterization of planar capacitive imaging probe based on the measurement sensitivity distribution

    NASA Astrophysics Data System (ADS)

    Yin, X.; Chen, G.; Li, W.; Huthchins, D. A.

    2013-01-01

    Previous work indicated that the capacitive imaging (CI) technique is a useful NDE tool which can be used on a wide range of materials, including metals, glass/carbon fibre composite materials and concrete. The imaging performance of the CI technique for a given application is determined by design parameters and characteristics of the CI probe. In this paper, a rapid method for calculating the whole probe sensitivity distribution based on the finite element model (FEM) is presented to provide a direct view of the imaging capabilities of the planar CI probe. Sensitivity distributions of CI probes with different geometries were obtained. Influencing factors on sensitivity distribution were studied. Comparisons between CI probes with point-to-point triangular electrode pair and back-to-back triangular electrode pair were made based on the analysis of the corresponding sensitivity distributions. The results indicated that the sensitivity distribution could be useful for optimising the probe design parameters and predicting the imaging performance.

  15. Evaluation of radioisotope tracer and activation analysis techniques for contamination monitoring in space environment simulation chambers

    NASA Technical Reports Server (NTRS)

    Smathers, J. B.; Kuykendall, W. E., Jr.; Wright, R. E., Jr.; Marshall, J. R.

    1973-01-01

    Radioisotope measurement techniques and neutron activation analysis are evaluated for use in identifying and locating contamination sources in space environment simulation chambers. The alpha range method allows the determination of total contaminant concentration in vapor state and condensate state. A Cf-252 neutron activation analysis system for detecting oils and greases tagged with stable elements is described. While neutron activation analysis of tagged contaminants offers specificity, an on-site system is extremely costly to implement and provides only marginal detection sensitivity under even the most favorable conditions.

  16. Neutron activation analysis for antimetabolites. [in food samples

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  17. Time resolved analysis of quetiapine and 7-OH-quetiapine in hair using LC/MS-MS.

    PubMed

    Binz, Tina M; Yegles, Michel; Schneider, Serge; Neels, Hugo; Crunelle, Cleo L

    2014-09-01

    Hair analysis is a powerful tool for retrospective drug analysis and has a wide application window. This article describes the simultaneous determination and quantification of the short-acting atypical antipsychotic drug quetiapine and its main metabolite 7-OH quetiapine in hair. A sensitive and accurate method for the determination of these two compounds was developed using high-performance liquid chromatography coupled to tandem mass spectrometry detection (LC-MS/MS). The method was applied to 10 real case samples. For five patients, a time resolved hair analysis was done. Results varied from 0.35 ng/mg to 10.21 ng/mg hair for quetiapine and from 0.02 ng/mg to 3.19 ng/mg hair for 7-OH-quetiapine. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Sensitivity and specificity of univariate MRI analysis of experimentally degraded cartilage

    PubMed Central

    Lin, Ping-Chang; Reiter, David A.; Spencer, Richard G.

    2010-01-01

    MRI is increasingly used to evaluate cartilage in tissue constructs, explants, and animal and patient studies. However, while mean values of MR parameters, including T1, T2, magnetization transfer rate km, apparent diffusion coefficient ADC, and the dGEMRIC-derived fixed charge density, correlate with tissue status, the ability to classify tissue according to these parameters has not been explored. Therefore, the sensitivity and specificity with which each of these parameters was able to distinguish between normal and trypsin- degraded, and between normal and collagenase-degraded, cartilage explants were determined. Initial analysis was performed using a training set to determine simple group means to which parameters obtained from a validation set were compared. T1 and ADC showed the greatest ability to discriminate between normal and degraded cartilage. Further analysis with k-means clustering, which eliminates the need for a priori identification of sample status, generally performed comparably. Use of fuzzy c-means (FCM) clustering to define centroids likewise did not result in improvement in discrimination. Finally, a FCM clustering approach in which validation samples were assigned in a probabilistic fashion to control and degraded groups was implemented, reflecting the range of tissue characteristics seen with cartilage degradation. PMID:19705467

  19. Measurement Consistency from Magnetic Resonance Images

    PubMed Central

    Chung, Dongjun; Chung, Moo K.; Durtschi, Reid B.; Lindell, R. Gentry; Vorperian, Houri K.

    2010-01-01

    Rationale and Objectives In quantifying medical images, length-based measurements are still obtained manually. Due to possible human error, a measurement protocol is required to guarantee the consistency of measurements. In this paper, we review various statistical techniques that can be used in determining measurement consistency. The focus is on detecting a possible measurement bias and determining the robustness of the procedures to outliers. Materials and Methods We review correlation analysis, linear regression, Bland-Altman method, paired t-test, and analysis of variance (ANOVA). These techniques were applied to measurements, obtained by two raters, of head and neck structures from magnetic resonance images (MRI). Results The correlation analysis and the linear regression were shown to be insufficient for detecting measurement inconsistency. They are also very sensitive to outliers. The widely used Bland-Altman method is a visualization technique so it lacks the numerical quantification. The paired t-test tends to be sensitive to small measurement bias. On the other hand, ANOVA performs well even under small measurement bias. Conclusion In almost all cases, using only one method is insufficient and it is recommended to use several methods simultaneously. In general, ANOVA performs the best. PMID:18790405

  20. Digital data processing system dynamic loading analysis

    NASA Technical Reports Server (NTRS)

    Lagas, J. J.; Peterka, J. J.; Tucker, A. E.

    1976-01-01

    Simulation and analysis of the Space Shuttle Orbiter Digital Data Processing System (DDPS) are reported. The mated flight and postseparation flight phases of the space shuttle's approach and landing test configuration were modeled utilizing the Information Management System Interpretative Model (IMSIM) in a computerized simulation modeling of the ALT hardware, software, and workload. System requirements simulated for the ALT configuration were defined. Sensitivity analyses determined areas of potential data flow problems in DDPS operation. Based on the defined system requirements and the sensitivity analyses, a test design is described for adapting, parameterizing, and executing the IMSIM. Varying load and stress conditions for the model execution are given. The analyses of the computer simulation runs were documented as results, conclusions, and recommendations for DDPS improvements.

  1. Critical factors determining the quantification capability of matrix-assisted laser desorption/ionization– time-of-flight mass spectrometry

    PubMed Central

    Wang, Chia-Chen; Lai, Yin-Hung; Ou, Yu-Meng; Chang, Huan-Tsung; Wang, Yi-Sheng

    2016-01-01

    Quantitative analysis with mass spectrometry (MS) is important but challenging. Matrix-assisted laser desorption/ionization (MALDI) coupled with time-of-flight (TOF) MS offers superior sensitivity, resolution and speed, but such techniques have numerous disadvantages that hinder quantitative analyses. This review summarizes essential obstacles to analyte quantification with MALDI-TOF MS, including the complex ionization mechanism of MALDI, sensitive characteristics of the applied electric fields and the mass-dependent detection efficiency of ion detectors. General quantitative ionization and desorption interpretations of ion production are described. Important instrument parameters and available methods of MALDI-TOF MS used for quantitative analysis are also reviewed. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644968

  2. Fast BIA-amperometric determination of isoniazid in tablets.

    PubMed

    Quintino, Maria S M; Angnes, Lúcio

    2006-09-26

    This paper proposes a new, fast and precise method to analyze isoniazid based on the electrochemical oxidation of the analyte at a glassy carbon electrode in 0.1M NaOH. The quantification was performed utilizing amperometry associated with batch injection analysis (BIA) technique. Fast sequential analysis (60 determinations h(-1)) in an unusually wide linear dynamic range (from 2.5 x 10(-8) to 1.0 x 10(-3)M), with high sensitivity and low limits of detection (4.1 x 10(-9)M) and quantification (1.4 x 10(-8)M), was achieved. Such characteristics allied to a good repeatability of the current responses (relative standard deviation of 0.79% for 30 measurements), were explored for the specific determination of isoniazid in isoniazid-rifampin tablet.

  3. Sensitive determination of cholesterol and its metabolic steroid hormones by UHPLC-MS/MS via derivatization coupled with dual ultrasonic-assisted dispersive liquid-liquid microextraction.

    PubMed

    Zhao, Xian-En; Yan, Ping; Wang, Renjun; Zhu, Shuyun; You, Jinmao; Bai, Yu; Liu, Huwei

    2016-08-01

    Quantitative analysis of cholesterol and its metabolic steroid hormones plays a vital role in diagnosing endocrine disorders and understanding disease progression, as well as in clinical medicine studies. Because of their extremely low abundance in body fluids, it remains a challenging task to develop a sensitive detection method. A hyphenated technique of dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) was proposed for cleansing, enrichment and sensitivity enhancement. 4'-Carboxy-substituted rosamine (CSR) was synthesized and used as derivatization reagent. An ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for determination of cholesterol and its metabolic steroid hormones in the multiple reaction monitoring mode. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS were all optimized. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.08-0.15 pg mL(-1) ) were achieved. Through the combination of dual-UADLLME and MAD, a determination method for cholesterol and its metabolic steroid hormones in human plasma, serum and urine samples was developed and validated with high sensitivity, selectivity, accuracy and perfect matrix effect results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Sensitivity Analysis for Steady State Groundwater Flow Using Adjoint Operators

    NASA Astrophysics Data System (ADS)

    Sykes, J. F.; Wilson, J. L.; Andrews, R. W.

    1985-03-01

    Adjoint sensitivity theory is currently being considered as a potential method for calculating the sensitivity of nuclear waste repository performance measures to the parameters of the system. For groundwater flow systems, performance measures of interest include piezometric heads in the vicinity of a waste site, velocities or travel time in aquifers, and mass discharge to biosphere points. The parameters include recharge-discharge rates, prescribed boundary heads or fluxes, formation thicknesses, and hydraulic conductivities. The derivative of a performance measure with respect to the system parameters is usually taken as a measure of sensitivity. To calculate sensitivities, adjoint sensitivity equations are formulated from the equations describing the primary problem. The solution of the primary problem and the adjoint sensitivity problem enables the determination of all of the required derivatives and hence related sensitivity coefficients. In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Alternatively, local velocity related performance measures are more sensitive to hydraulic conductivities.

  5. Sensitive determination of melamine in milk and powdered infant formula samples by high-performance liquid chromatography using dabsyl chloride derivatization followed by dispersive liquid-liquid microextraction.

    PubMed

    Faraji, M; Adeli, M

    2017-04-15

    A new and sensitive pre-column derivatization with dabsyl chloride followed by dispersive liquid-liquid microextraction was developed for the analysis of melamine (MEL) in raw milk and powdered infant formula samples by high performance liquid chromatography (HPLC) with visible detection. Derivatization with dabsyl chloride leads to improving sensitivity and hydrophobicity of MEL. Under optimum conditions of derivatization and microextraction steps, the method yielded a linear calibration curve ranging from 1.0 to 500μgL -1 with a determination coefficient (R 2 ) of 0.9995. Limit of detection and limit of quantification were 0.1 and 0.3μgL -1 , respectively. The relative standard deviation (RSD%) for intra-day (repeatability) and inter-day (reproducibility) at 25 and 100μgL -1 levels of MEL was less than 7.0% (n=6). Finally, the proposed method was successfully applied for the preconcentration and determination of MEL in different raw milk and powdered infant formula, and satisfactory results were obtained (relative recovery ⩾94%). Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 40 CFR 63.786 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... by Gas Chromatography (incorporation by reference—see § 63.14). In determining the sensitivity, the... Practice for Gas Chromatography [incorporation by reference—see § 63.14].) (c) A coating manufacturer or... mixture under analysis are not known. In such cases a single column gas chromatograph (GC) may not be...

  7. 40 CFR 63.786 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... by Gas Chromatography (incorporation by reference—see § 63.14). In determining the sensitivity, the... Practice for Gas Chromatography [incorporation by reference—see § 63.14].) (c) A coating manufacturer or... mixture under analysis are not known. In such cases a single column gas chromatograph (GC) may not be...

  8. The treatment of missing data in a large cardiovascular clinical outcomes study.

    PubMed

    Little, Roderick J; Wang, Julia; Sun, Xiang; Tian, Hong; Suh, Eun-Young; Lee, Michael; Sarich, Troy; Oppenheimer, Leonard; Plotnikov, Alexei; Wittes, Janet; Cook-Bruns, Nancy; Burton, Paul; Gibson, C Michael; Mohanty, Surya

    2016-06-01

    The potential impact of missing data on the results of clinical trials has received heightened attention recently. A National Research Council study provides recommendations for limiting missing data in clinical trial design and conduct, and principles for analysis, including the need for sensitivity analyses to assess robustness of findings to alternative assumptions about the missing data. A Food and Drug Administration advisory committee raised missing data as a serious concern in their review of results from the ATLAS ACS 2 TIMI 51 study, a large clinical trial that assessed rivaroxaban for its ability to reduce the risk of cardiovascular death, myocardial infarction or stroke in patients with acute coronary syndrome. This case study describes a variety of measures that were taken to address concerns about the missing data. A range of analyses are described to assess the potential impact of missing data on conclusions. In particular, measures of the amount of missing data are discussed, and the fraction of missing information from multiple imputation is proposed as an alternative measure. The sensitivity analysis in the National Research Council study is modified in the context of survival analysis where some individuals are lost to follow-up. The impact of deviations from ignorable censoring is assessed by differentially increasing the hazard of the primary outcome in the treatment groups and multiply imputing events between dropout and the end of the study. Tipping-point analyses are described, where the deviation from ignorable censoring that results in a reversal of significance of the treatment effect is determined. A study to determine the vital status of participants lost to follow-up was also conducted, and the results of including this additional information are assessed. Sensitivity analyses suggest that findings of the ATLAS ACS 2 TIMI 51 study are robust to missing data; this robustness is reinforced by the follow-up study, since inclusion of data from this study had little impact on the study conclusions. Missing data are a serious problem in clinical trials. The methods presented here, namely, the sensitivity analyses, the follow-up study to determine survival of missing cases, and the proposed measurement of missing data via the fraction of missing information, have potential application in other studies involving survival analysis where missing data are a concern. © The Author(s) 2016.

  9. Distinct Contributory Factors Determine Basophil-Allergen Sensitivity in Grass Pollen Rhinitis and in Anaphylactic Wasp Venom Allergy.

    PubMed

    Korošec, Peter; Šilar, Mira; Kopač, Peter; Eržen, Renato; Zidarn, Mihaela; Košnik, Mitja

    2016-01-01

    We sought to determine whether basophil-allergen sensitivity could be transferred to donor basophils by passive IgE sensitisation in allergic rhinitis and anaphylactic Hymenoptera venom hypersensitivity. We studied 15 wasp venom-, 19 grass pollen- and 2 house dust mite-allergic patients, 2 healthy donors, and 8 wasp venom-allergic donors. In all subjects, we first evaluated the initial basophil response to wasp venom, grass pollen, or house dust mite allergen. Donor basophils were then stripped, sensitised with the different patients' serum IgE, and challenged with the corresponding allergen. The CD63 response of donor basophils was then compared with initial basophil responses. In wasp venom-allergic subjects, the IgE transfer did not reflect the initial basophil-allergen sensitivity, because the venom IgE of subjects with high or low basophil sensitivity induced comparable responsiveness in healthy donor basophils. Furthermore, vice versa, when we sensitised the donor basophils of wasp venom-allergic individuals with different wasp venom or house dust mite IgE, we demonstrated that their response was predictable by their initial basophil allergen sensitivity. In the rhinitis allergy model, the IgE transfer correlated with the patients' initial basophil responsiveness because the grass pollen IgE of the subjects with high basophil allergen sensitivity induced significantly higher responsiveness of donor basophils than the IgE of subjects with initially low basophil allergen sensitivity. Our results suggest that basophil allergen sensitivity evaluated by flow-cytometric CD63 analysis depends on two distinct contribution factors. In anaphylactic Hymenoptera allergy, the major factor was intrinsic cellular sensitivity, whereas in pollen allergy, the major factor was allergen-specific IgE on the cell surface. © 2016 S. Karger AG, Basel.

  10. LC-MS-based characterization of the peptide reactivity of chemicals to improve the in vitro prediction of the skin sensitization potential.

    PubMed

    Natsch, Andreas; Gfeller, Hans

    2008-12-01

    A key step in the skin sensitization process is the formation of a covalent adduct between skin sensitizers and endogenous proteins and/or peptides in the skin. Based on this mechanistic understanding, there is a renewed interest in in vitro assays to determine the reactivity of chemicals toward peptides in order to predict their sensitization potential. A standardized peptide reactivity assay yielded a promising predictivity. This published assay is based on high-performance liquid chromatography with ultraviolet detection to quantify peptide depletion after incubation with test chemicals. We had observed that peptide depletion may be due to either adduct formation or peptide oxidation. Here we report a modified assay based on both liquid chromatography-mass spectrometry (LC-MS) analysis and detection of free thiol groups. This approach allows simultaneous determination of (1) peptide depletion, (2) peptide oxidation (dimerization), (3) adduct formation, and (4) thiol reactivity and thus generates a more detailed characterization of the reactivity of a molecule. Highly reactive molecules are further discriminated with a kinetic measure. The assay was validated on 80 chemicals. Peptide depletion could accurately be quantified both with LC-MS detection and depletion of thiol groups. The majority of the moderate/strong/extreme sensitizers formed detectable peptide adducts, but many sensitizers were also able to catalyze peptide oxidation. Whereas adduct formation was only observed for sensitizers, this oxidation reaction was also observed for two nonsensitizing fragrance aldehydes, indicating that peptide depletion might not always be regarded as sufficient evidence for rating a chemical as a sensitizer. Thus, this modified assay gives a more informed view of the peptide reactivity of chemicals to better predict their sensitization potential.

  11. Sensitivity Analysis in Engineering

    NASA Technical Reports Server (NTRS)

    Adelman, Howard M. (Compiler); Haftka, Raphael T. (Compiler)

    1987-01-01

    The symposium proceedings presented focused primarily on sensitivity analysis of structural response. However, the first session, entitled, General and Multidisciplinary Sensitivity, focused on areas such as physics, chemistry, controls, and aerodynamics. The other four sessions were concerned with the sensitivity of structural systems modeled by finite elements. Session 2 dealt with Static Sensitivity Analysis and Applications; Session 3 with Eigenproblem Sensitivity Methods; Session 4 with Transient Sensitivity Analysis; and Session 5 with Shape Sensitivity Analysis.

  12. The clinical relevance of birch pollen profilin cross-reactivity in sensitized patients.

    PubMed

    Wölbing, F; Kunz, J; Kempf, W E; Grimmel, C; Fischer, J; Biedermann, T

    2017-04-01

    Overlapping seasons and cross-reactivity, especially to grass pollen profilin, can hamper the diagnosis of birch pollen allergy. To identify the primary sensitizing allergen and the clinical relevance of cross-sensitization, we correlated sensitization profiles with in vitro and in vivo tests, symptom scores, and pollen counts. A total of 433 patients with positive skin prick test (SPT) to birch pollen were analyzed regarding IgE to major birch and grass pollen allergens Bet v 1 and Phl p 1/p 5 and the profilins Bet v 2 and Phl p 12. Subgroups were analyzed by basophil activation test (BAT) and CAP-FEIA-based cross- and self-inhibition tests. A total of 349 patients were sensitized to Bet v 1, 44 patients to both Bet v 1 and Bet v 2, and 15 patients to Bet v 2 only. From Bet v 2-sensitized patients, 40 were also sensitized to Phl p 12. Ex vivo, Bet v 2 and Phl p 12 induced dose-dependent activation in basophils of these patients. Cross- and self-inhibition tests with both allergens confirmed cross-reactivity. However, semiquantitative analysis of SPTs demonstrated markedly increased reactivity to grass compared to birch pollen extract in Bet v 2 only sensitized patients. Accordingly, in most of those patients, clinical symptoms precisely correlated with grass pollen counts. Identification of the clinically relevant and sensitizing allergen needs correlation of actual pollen counts with clinical symptoms and sensitization status to major allergens. Semiquantitative analysis of SPT or BAT and determining profilin-specific IgE can contribute to making the diagnosis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. [Enzymatic methods in the analysis of musts and wines].

    PubMed

    Lafon-Lafourcade, S

    1978-01-01

    The enzymatic methods are based on the property of the enzymes to catalyse specifically and reversibly the conversion of certain metabolites. These methods, developed thanks to the industrial preparation of enzymes, can be applied with no major modification to the analysis of drinks. About 15 constituants of musts and wines can now be determined by these methods. If their cost price was not relatively high, their specificity, sensitivity and rapidity would enable them to compete with the most precise of chemical methods. This is why they are only used in analytic oenology when chemical analysis is most specific enough or too laborious. Enzymatic measurement allows one by its specificity to determine the amount of residual sugar that is fermentable in a dry wine and by its sensitivity to verifie the total disappearance of the malic acid of the wine. Its rapidity must make it preferable to the long and not very specific chemical measurement, especially concerning the determination of citric acid. But glycerol, ethanol and acetic acid can be measured by chemical or chromatographical means with sufficient precision and for a more modest price. In oenology the methods are essentially used for research. They have permitted the study of the combinations of sulphur anhydride in wines (measurement of cetonic acids). The determination of the isomeric nature of the lactic acid produced from sugars by lactic bacteria is based on their application; this determination is a criterium for the identification and classification of these microorganisms. The measurement of the lactic acid during vinification allows the early disclosure of the first effects of a bacterial development; inversely it permits the invalidation of the existence of a lactic sourness, which a high volatile acidity might point to. Lastly, the enzymatic measurement of gluconic acid allows the health of the crop to be controlled.

  14. EBUS-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration

    PubMed Central

    Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan

    2016-01-01

    Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. PMID:26912301

  15. Endobronchial Ultrasound-Guided Cautery-Assisted Transbronchial Forceps Biopsies: Safety and Sensitivity Relative to Transbronchial Needle Aspiration.

    PubMed

    Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T

    2016-05-01

    Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Vitrectomy for the diagnosis and management of uveitis of unknown cause.

    PubMed

    Margolis, Ron; Brasil, Oswaldo F M; Lowder, Careen Y; Singh, Rishi P; Kaiser, Peter K; Smith, Scott D; Perez, Victor L; Sonnie, Christine; Sears, Jonathan E

    2007-10-01

    To determine the diagnostic yield of tests commonly used for vitreous fluid analysis in eyes with suspected intraocular infection or malignancy. Noncomparative interventional case series. Forty-four consecutive patients (45 eyes) treated from 1998 through 2006 with posterior segment inflammation who underwent pars plana vitrectomy for diagnostic purposes. Vitreous specimens obtained via pars plana vitrectomy were analyzed by microbiologic culture, cytologic analysis, and flow cytometry. Diagnostic yield and sensitivity of each test performed on vitreous specimens and visual outcomes of eyes that underwent diagnostic vitrectomy (DVx). Preoperative diagnoses were infection in 15 eyes and malignancy in 30 eyes. Overall, vitreous analysis identified a specific cause in 9 (20%) of 45 eyes. The overall sensitivity of DVx was 63.6%. The sensitivities of individual tests were: culture, 50%; cytologic analysis, 66.7%; and flow cytometry, 83.3%. The yields of diagnostic tests were: culture, 5.7%; cytologic analysis, 14.3%; and flow cytometry, 20.6%. Final diagnoses were infection in 6 eyes, malignancy in 9 eyes, and idiopathic in 30 eyes. Mean visual acuity improved significantly in the first 6 months after DVx. Visual acuity improved in 60% of eyes, with 37.8% of eyes improving by 3 lines or more. Analysis of vitreous fluid by widely available tests is useful in identifying intraocular infection or malignancy. Most patients experienced a substantial improvement in vision.

  17. Behavior sensitivities for control augmented structures

    NASA Technical Reports Server (NTRS)

    Manning, R. A.; Lust, R. V.; Schmit, L. A.

    1987-01-01

    During the past few years it has been recognized that combining passive structural design methods with active control techniques offers the prospect of being able to find substantially improved designs. These developments have stimulated interest in augmenting structural synthesis by adding active control system design variables to those usually considered in structural optimization. An essential step in extending the approximation concepts approach to control augmented structural synthesis is the development of a behavior sensitivity analysis capability for determining rates of change of dynamic response quantities with respect to changes in structural and control system design variables. Behavior sensitivity information is also useful for man-machine interactive design as well as in the context of system identification studies. Behavior sensitivity formulations for both steady state and transient response are presented and the quality of the resulting derivative information is evaluated.

  18. Methods for comparative evaluation of propulsion system designs for supersonic aircraft

    NASA Technical Reports Server (NTRS)

    Tyson, R. M.; Mairs, R. Y.; Halferty, F. D., Jr.; Moore, B. E.; Chaloff, D.; Knudsen, A. W.

    1976-01-01

    The propulsion system comparative evaluation study was conducted to define a rapid, approximate method for evaluating the effects of propulsion system changes for an advanced supersonic cruise airplane, and to verify the approximate method by comparing its mission performance results with those from a more detailed analysis. A table look up computer program was developed to determine nacelle drag increments for a range of parametric nacelle shapes and sizes. Aircraft sensitivities to propulsion parameters were defined. Nacelle shapes, installed weights, and installed performance was determined for four study engines selected from the NASA supersonic cruise aircraft research (SCAR) engine studies program. Both rapid evaluation method (using sensitivities) and traditional preliminary design methods were then used to assess the four engines. The method was found to compare well with the more detailed analyses.

  19. Sensitivity of projected long-term CO2 emissions across the Shared Socioeconomic Pathways

    NASA Astrophysics Data System (ADS)

    Marangoni, G.; Tavoni, M.; Bosetti, V.; Borgonovo, E.; Capros, P.; Fricko, O.; Gernaat, D. E. H. J.; Guivarch, C.; Havlik, P.; Huppmann, D.; Johnson, N.; Karkatsoulis, P.; Keppo, I.; Krey, V.; Ó Broin, E.; Price, J.; van Vuuren, D. P.

    2017-01-01

    Scenarios showing future greenhouse gas emissions are needed to estimate climate impacts and the mitigation efforts required for climate stabilization. Recently, the Shared Socioeconomic Pathways (SSPs) have been introduced to describe alternative social, economic and technical narratives, spanning a wide range of plausible futures in terms of challenges to mitigation and adaptation. Thus far the key drivers of the uncertainty in emissions projections have not been robustly disentangled. Here we assess the sensitivities of future CO2 emissions to key drivers characterizing the SSPs. We use six state-of-the-art integrated assessment models with different structural characteristics, and study the impact of five families of parameters, related to population, income, energy efficiency, fossil fuel availability, and low-carbon energy technology development. A recently developed sensitivity analysis algorithm allows us to parsimoniously compute both the direct and interaction effects of each of these drivers on cumulative emissions. The study reveals that the SSP assumptions about energy intensity and economic growth are the most important determinants of future CO2 emissions from energy combustion, both with and without a climate policy. Interaction terms between parameters are shown to be important determinants of the total sensitivities.

  20. A Retrospective Estimate of Ear Disease Detection Using the "Red Flags" in a Clinical Sample.

    PubMed

    Klyn, Niall A M; Kleindienst Robler, Samantha; Alfakir, Razan; Nielsen, Donald W; Griffith, James W; Carlson, Deborah L; Lundy, Larry; Dhar, Sumitrajit; Zapala, David A

    2018-03-01

    The purpose of this study was to evaluate the specificity and sensitivity of two red flag protocols in detecting ear diseases associated with changes in hearing. The presence of red-flag symptoms was determined in a chart review of 307 adult patients from the Mayo Clinic Florida Departments of Otorhinolaryngology and Audiology. Participants formed a convenience sample recruited for a separate study. Neurotologist diagnosis was the criterion for comparisons. Of the 251 patient files retained for analysis, 191 had one or more targeted diseases and 60 had age- or noise-related hearing loss. Food and Drug Administration red flags sensitivity was 91% (confidence interval [CI], 86 to 95%) and specificity was 72% (CI, 59 to 83%). American Academy of Otolaryngology-Head and Neck Surgery red flags sensitivity was 98% (CI, 95 to 99%) and specificity was 20% (CI, 11 to 32%). Stakeholders must determine which diseases are meaningful contraindications for hearing aid use and whether these red-flag protocols have acceptable levels of sensitivity and specificity. As direct-to-consumer models of hearing devices increase, a disease detection method that does not require provider intercession would be useful.

  1. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.

    PubMed

    Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui

    2008-12-01

    A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.

  2. A generalized matching law analysis of cocaine vs. food choice in rhesus monkeys: effects of candidate 'agonist-based' medications on sensitivity to reinforcement.

    PubMed

    Hutsell, Blake A; Negus, S Stevens; Banks, Matthew L

    2015-01-01

    We have previously demonstrated reductions in cocaine choice produced by either continuous 14-day phendimetrazine and d-amphetamine treatment or removing cocaine availability under a cocaine vs. food choice procedure in rhesus monkeys. The aim of the present investigation was to apply the concatenated generalized matching law (GML) to cocaine vs. food choice dose-effect functions incorporating sensitivity to both the relative magnitude and price of each reinforcer. Our goal was to determine potential behavioral mechanisms underlying pharmacological treatment efficacy to decrease cocaine choice. A multi-model comparison approach was used to characterize dose- and time-course effects of both pharmacological and environmental manipulations on sensitivity to reinforcement. GML models provided an excellent fit of the cocaine choice dose-effect functions in individual monkeys. Reductions in cocaine choice by both pharmacological and environmental manipulations were principally produced by systematic decreases in sensitivity to reinforcer price and non-systematic changes in sensitivity to reinforcer magnitude. The modeling approach used provides a theoretical link between the experimental analysis of choice and pharmacological treatments being evaluated as candidate 'agonist-based' medications for cocaine addiction. The analysis suggests that monoamine releaser treatment efficacy to decrease cocaine choice was mediated by selectively increasing the relative price of cocaine. Overall, the net behavioral effect of these pharmacological treatments was to increase substitutability of food pellets, a nondrug reinforcer, for cocaine. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Sensitivity analysis of a new dual-porosity hydroloigcal model coupled with the SOSlope model for the numerical simulations of rainfall triggered shallow landslides.

    NASA Astrophysics Data System (ADS)

    Schwarz, Massimiliano; Cohen, Denis

    2017-04-01

    Morphology and extent of hydrological pathways, in combination with the spatio-temporal variability of rainfall events and the heterogeneities of hydro-mechanical properties of soils, has a major impact on the hydrological conditions that locally determine the triggering of shallow landslides. The coupling of these processes at different spatial scales is an enormous challenge for slope stability modeling at the catchment scale. In this work we present a sensitivity analysis of a new dual-porosity hydrological model implemented in the hydro-mechanical model SOSlope for the modeling of shallow landslides on vegetated hillslopes. The proposed model links the calculation of the saturation dynamic of preferential flow-paths based on hydrological and topographical characteristics of the landscape to the hydro-mechanical behavior of the soil along a potential failure surface due to the changes of soil matrix saturation. Furthermore, the hydro-mechanical changes of soil conditions are linked to the local stress-strain properties of the (rooted-)soil that ultimately determine the force redistribution and related deformations at the hillslope scale. The model considers forces to be redistributed through three types of solicitations: tension, compression, and shearing. The present analysis shows how the conditions of deformation due to the passive earth pressure mobilized at the toe of the landslide are particularly important in defining the timing and extension of shallow landslides. The model also shows that, in densely rooted hillslopes, lateral force redistribution under tension through the root-network may substantially contribute to stabilizing slopes, avoiding crack formation and large deformations. The results of the sensitivity analysis are discussed in the context of protection forest management and bioengineering techniques.

  4. Sensitivity analysis of observed reflectivity to ice particle surface roughness using MISR satellite observations

    NASA Astrophysics Data System (ADS)

    Bell, A.; Hioki, S.; Wang, Y.; Yang, P.; Di Girolamo, L.

    2016-12-01

    Previous studies found that including ice particle surface roughness in forward light scattering calculations significantly reduces the differences between observed and simulated polarimetric and radiometric observations. While it is suggested that some degree of roughness is desirable, the appropriate degree of surface roughness to be assumed in operational cloud property retrievals and the sensitivity of retrieval products to this assumption remains uncertain. In an effort to extricate this ambiguity, we will present a sensitivity analysis of space-borne multi-angle observations of reflectivity, to varying degrees of surface roughness. This process is two fold. First, sampling information and statistics of Multi-angle Imaging SpectroRadiometer (MISR) sensor data aboard the Terra platform, will be used to define the most coming viewing observation geometries. Using these defined geometries, reflectivity will be simulated for multiple degrees of roughness using results from adding-doubling radiative transfer simulations. Sensitivity of simulated reflectivity to surface roughness can then be quantified, thus yielding a more robust retrieval system. Secondly, sensitivity of the inverse problem will be analyzed. Spherical albedo values will be computed by feeding blocks of MISR data comprising cloudy pixels over ocean into the retrieval system, with assumed values of surface roughness. The sensitivity of spherical albedo to the inclusion of surface roughness can then be quantified, and the accuracy of retrieved parameters can be determined.

  5. Identification of the most sensitive parameters in the activated sludge model implemented in BioWin software.

    PubMed

    Liwarska-Bizukojc, Ewa; Biernacki, Rafal

    2010-10-01

    In order to simulate biological wastewater treatment processes, data concerning wastewater and sludge composition, process kinetics and stoichiometry are required. Selection of the most sensitive parameters is an important step of model calibration. The aim of this work is to verify the predictability of the activated sludge model, which is implemented in BioWin software, and select its most influential kinetic and stoichiometric parameters with the help of sensitivity analysis approach. Two different measures of sensitivity are applied: the normalised sensitivity coefficient (S(i,j)) and the mean square sensitivity measure (delta(j)(msqr)). It occurs that 17 kinetic and stoichiometric parameters of the BioWin activated sludge (AS) model can be regarded as influential on the basis of S(i,j) calculations. Half of the influential parameters are associated with growth and decay of phosphorus accumulating organisms (PAOs). The identification of the set of the most sensitive parameters should support the users of this model and initiate the elaboration of determination procedures for the parameters, for which it has not been done yet. Copyright 2010 Elsevier Ltd. All rights reserved.

  6. Computational Analysis of Epidermal Growth Factor Receptor Mutations Predicts Differential Drug Sensitivity Profiles toward Kinase Inhibitors.

    PubMed

    Akula, Sravani; Kamasani, Swapna; Sivan, Sree Kanth; Manga, Vijjulatha; Vudem, Dashavantha Reddy; Kancha, Rama Krishna

    2018-05-01

    A significant proportion of patients with lung cancer carry mutations in the EGFR kinase domain. The presence of a deletion mutation in exon 19 or L858R point mutation in the EGFR kinase domain has been shown to cause enhanced efficacy of inhibitor treatment in patients with NSCLC. Several less frequent (uncommon) mutations in the EGFR kinase domain with potential implications in treatment response have also been reported. The role of a limited number of uncommon mutations in drug sensitivity was experimentally verified. However, a huge number of these mutations remain uncharacterized for inhibitor sensitivity or resistance. A large-scale computational analysis of clinically reported 298 point mutants of EGFR kinase domain has been performed, and drug sensitivity profiles for each mutant toward seven kinase inhibitors has been determined by molecular docking. In addition, the relative inhibitor binding affinity toward each drug as compared with that of adenosine triphosphate was calculated for each mutant. The inhibitor sensitivity profiles predicted in this study for a set of previously characterized mutants correlated well with the published clinical, experimental, and computational data. Both the single and compound mutations displayed differential inhibitor sensitivity toward first- and next-generation kinase inhibitors. The present study provides predicted drug sensitivity profiles for a large panel of uncommon EGFR mutations toward multiple inhibitors, which may help clinicians in deciding mutant-specific treatment strategies. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  7. [Measurement of Water COD Based on UV-Vis Spectroscopy Technology].

    PubMed

    Wang, Xiao-ming; Zhang, Hai-liang; Luo, Wei; Liu, Xue-mei

    2016-01-01

    Ultraviolet/visible (UV/Vis) spectroscopy technology was used to measure water COD. A total of 135 water samples were collected from Zhejiang province. Raw spectra with 3 different pretreatment methods (Multiplicative Scatter Correction (MSC), Standard Normal Variate (SNV) and 1st Derivatives were compared to determine the optimal pretreatment method for analysis. Spectral variable selection is an important strategy in spectrum modeling analysis, because it tends to parsimonious data representation and can lead to multivariate models with better performance. In order to simply calibration models, the preprocessed spectra were then used to select sensitive wavelengths by competitive adaptive reweighted sampling (CARS), Random frog and Successive Genetic Algorithm (GA) methods. Different numbers of sensitive wavelengths were selected by different variable selection methods with SNV preprocessing method. Partial least squares (PLS) was used to build models with the full spectra, and Extreme Learning Machine (ELM) was applied to build models with the selected wavelength variables. The overall results showed that ELM model performed better than PLS model, and the ELM model with the selected wavelengths based on CARS obtained the best results with the determination coefficient (R2), RMSEP and RPD were 0.82, 14.48 and 2.34 for prediction set. The results indicated that it was feasible to use UV/Vis with characteristic wavelengths which were obtained by CARS variable selection method, combined with ELM calibration could apply for the rapid and accurate determination of COD in aquaculture water. Moreover, this study laid the foundation for further implementation of online analysis of aquaculture water and rapid determination of other water quality parameters.

  8. Direct sampling graphite furnace atomic absorption spectrometry - feasibility of Na and K determination in desalted crude oil

    NASA Astrophysics Data System (ADS)

    Seeger, Tassia S.; Machado, Eduarda Q.; Flores, Erico M. M.; Mello, Paola A.; Duarte, Fabio A.

    2018-03-01

    In this study, Na and K were determined in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS), with the use of a Zeeman-effect background correction system with variable magnetic field. The analysis was performed in low and high sensitivity conditions. Sodium determination was performed in two low-sensitivity conditions: 1) main absorption line (589.0 nm), gas stop flow during the atomization step and 3-field dynamic mode (0.6-0.8 T); and 2) secondary absorption line (330.3 nm), gas stop flow during the atomization and 2-field mode (0.8 T). In K determination, some parameters, such as high-sensitivity mode, main absorption line (766.5 nm), gas stop flow during the atomization and 2-field mode (0.8 T), were used. Suitability of chemical modifiers, such as Pd and W-Ir was also evaluated. The heating program for Na and K was based on the pyrolysis and atomization curves. Calibration was performed by aqueous standards. Accuracy was evaluated by the analysis of Green Petroleum Coke (SRM NIST 2718) and Trace Elements in Fuel Oil (SRM NIST 1634c). Recovery tests were also performed and results were compared with those obtained by GF AAS after crude oil digestion by microwave-assisted digestion. The characteristic mass of Na was 17.1 pg and 0.46 ng in conditions 1 and 2, respectively, while the one of K was 1.4 pg. Limits of detection and quantification by DS-GF AAS were 30 and 40 ng g-1 for Na and 3.2 and 4.2 ng g-1 for K, respectively. Sodium and K were determined in three crude oil samples with API density ranging from 20.9 to 28.0. Sodium and K concentration ranged from 1.5 to 73 μg g-1 and from 23 to 522 ng g-1, respectively.

  9. A surface enhanced Raman scattering quantitative analytical platform for detection of trace Cu coupled the catalytic reaction and gold nanoparticle aggregation with label-free Victoria blue B molecular probe.

    PubMed

    Li, Chongning; Ouyang, Huixiang; Tang, Xueping; Wen, Guiqing; Liang, Aihui; Jiang, Zhiliang

    2017-01-15

    With development of economy and society, there is an urgent need to develop convenient and sensitive methods for detection of Cu 2+ pollution in water. In this article, a simple and sensitive SERS sensor was proposed to quantitative analysis of trace Cu 2+ in water. The SERS sensor platform was prepared a common gold nanoparticle (AuNP)-SiO 2 sol substrate platform by adsorbing HSA, coupling with the catalytic reaction of Cu 2+ -ascorbic acid (H 2 A)-dissolved oxygen, and using label-free Victoria blue B (VBB) as SERS molecular probes. The SERS sensor platform response to the AuNP aggregations by hydroxyl radicals (•OH) oxidizing from the Cu 2+ catalytic reaction, which caused the SERS signal enhancement. Therefore, by monitoring the increase of SERS signal, Cu 2+ in water can be determined accurately. The results show that the SERS sensor platforms owns a linear response with a range from 0.025 to 25μmol/L Cu 2+ , and with a detection limit of 0.008μmol/L. In addition, the SERS method demonstrated good specificity for Cu 2+ , which can determined accurately trace Cu 2+ in water samples, and good recovery and accuracy are obtained for the water samples. With its high selectivity and good accuracy, the sensitive SERS quantitative analysis method is expected to be a promising candidate for determining copper ions in environmental monitoring and food safety. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Development of a structural optimization capability for the aeroelastic tailoring of composite rotor blades with straight and swept tips

    NASA Technical Reports Server (NTRS)

    Friedmann, P. P.; Venkatesan, C.; Yuan, K.

    1992-01-01

    This paper describes the development of a new structural optimization capability aimed at the aeroelastic tailoring of composite rotor blades with straight and swept tips. The primary objective is to reduce vibration levels in forward flight without diminishing the aeroelastic stability margins of the blade. In the course of this research activity a number of complicated tasks have been addressed: (1) development of a new, aeroelastic stability and response analysis; (2) formulation of a new comprehensive sensitive analysis, which facilitates the generation of the appropriate approximations for the objective and the constraints; (3) physical understanding of the new model and, in particular, determination of its potential for aeroelastic tailoring, and (4) combination of the newly developed analysis capability, the sensitivity derivatives and the optimizer into a comprehensive optimization capability. The first three tasks have been completed and the fourth task is in progress.

  11. Biosensors based on enzyme field-effect transistors for determination of some substrates and inhibitors.

    PubMed

    Dzyadevych, Sergei V; Soldatkin, Alexey P; Korpan, Yaroslav I; Arkhypova, Valentyna N; El'skaya, Anna V; Chovelon, Jean-Marc; Martelet, Claude; Jaffrezic-Renault, Nicole

    2003-10-01

    This paper is a review of the authors' publications concerning the development of biosensors based on enzyme field-effect transistors (ENFETs) for direct substrates or inhibitors analysis. Such biosensors were designed by using immobilised enzymes and ion-selective field-effect transistors (ISFETs). Highly specific, sensitive, simple, fast and cheap determination of different substances renders them as promising tools in medicine, biotechnology, environmental control, agriculture and the food industry. The biosensors based on ENFETs and direct enzyme analysis for determination of concentrations of different substrates (glucose, urea, penicillin, formaldehyde, creatinine, etc.) have been developed and their laboratory prototypes were fabricated. Improvement of the analytical characteristics of such biosensors may be achieved by using a differential mode of measurement, working solutions with different buffer concentrations and specific agents, negatively or positively charged additional membranes, or genetically modified enzymes. These approaches allow one to decrease the effect of the buffer capacity influence on the sensor response in an aim to increase the sensitivity of the biosensors and to extend their dynamic ranges. Biosensors for the determination of concentrations of different toxic substances (organophosphorous pesticides, heavy metal ions, hypochlorite, glycoalkaloids, etc.) were designed on the basis of reversible and/or irreversible enzyme inhibition effect(s). The conception of an enzymatic multibiosensor for the determination of different toxic substances based on the enzyme inhibition effect is also described. We will discuss the respective advantages and disadvantages of biosensors based on the ENFETs developed and also demonstrate their practical application.

  12. Evaluation of diatomea algae Thalassiosira weissflogii sensitivity to chloride mercury and methylmercury by chlorophyll fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Graevskaya, E. E.; Antal, T. K.; Matorin, D. N.; Voronova, E. N.; Pogosyan, S. I.; Rubin, A. B.

    2003-05-01

    Measurement of chlorophyll fluorescence has been shown to be a rapid, non-invasive, and reliable method to assess photosynthetic performance in a changing environment. In our study, the pulseamplitude-modulation (PAM) - fluorometric method was used to evaluate the sensitivity to chloride mercury and methylmercury chloride of diatomea microalgae Thalassiosira weissflogii. We found that 10^{-6} and 10^{-7} M MeHg led to a slow decrease in the PS II activity following for prolonged lag phase, whereas the algae was not sensitive to the same concentrations of HgCl2. However observed PS II inactivation by methylmercury was not complete and about 10 percents ofthe cells kept the high level of PS II activity as it was shown by microfluorometric analysis. These cells could determine adaptation of algae to methylmercury effect. Both toxicants decreased the rate of PS II reparation, as well as increased a heat pathway of excitation dissipation in PS II antennae complex.

  13. Chronic pesticide poisoning from persistent low-dose exposures in Ecuadorean floriculture workers: toward validating a low-cost test battery.

    PubMed

    Breilh, Jaime; Pagliccia, Nino; Yassi, Annalee

    2012-01-01

    Chronic pesticide poisoning is difficult to detect. We sought to develop a low-cost test battery for settings such as Ecuador's floriculture industry. First we had to develop a case definition; as with all occupational diseases a case had to have both sufficient effective dose and associated health effects. For the former, using canonical discriminant analysis, we found that adding measures of protection and overall environmental stressors to occupational category and duration of exposure was useful. For the latter, factor analysis suggested three distinct manifestations of pesticide poisoning. We then determined sensitivity and specificity of various combinations of symptoms and simple neurotoxicity tests from the Pentox questionnaire, and found that doing so increased sensitivity and specificity compared to use of acethylcholinesterase alone--the current screening standard. While sensitivity and specificity varied with different case definitions, our results support the development of a low-cost test battery for screening in such settings.

  14. Human salivary glucose analysis by high-performance ion-exchange chromatography and pulsed amperometric detection.

    PubMed

    Gough, H; Luke, G A; Beeley, J A; Geddes, D A

    1996-02-01

    The aim of this project was to develop an analytical procedure with the required level of sensitivity for the determination of glucose concentrations in small volumes of unstimulated fasting whole saliva. The technique involves high-performance ion-exchange chromatography at high pH and pulsed amperometric detection. It has a high level of reproducibility, a sensitivity as low as 0.1 mumol/l and requires only 50 microliters samples (sensitivity = 0.002 pmol). Inhibition of glucose metabolism, by procedures such as collection into 0.1% (w/v) sodium fluoride, was shown to be essential if accurate results are to be obtained. Collection on to ice followed by storage at -20 degrees C was shown to be unsuitable and resulted in glucose loss by degradation. There were inter- and intraindividual variations in the glucose concentration in unstimulated mixed saliva (range; 0.02-0.4 mmol/l). The procedure can be used for the analysis of other salivary carbohydrates and for monitoring the clearance of dietary carbohydrates from the mouth.

  15. A sensitivity analysis of volcanic aerosol dispersion in the stratosphere. [Mt. Fuego, Guatemala eruptions

    NASA Technical Reports Server (NTRS)

    Butler, C. F.

    1979-01-01

    A computer sensitivity analysis was performed to determine the uncertainties involved in the calculation of volcanic aerosol dispersion in the stratosphere using a 2 dimensional model. The Fuego volcanic event of 1974 was used. Aerosol dispersion processes that were included are: transport, sedimentation, gas phase sulfur chemistry, and aerosol growth. Calculated uncertainties are established from variations in the stratospheric aerosol layer decay times at 37 latitude for each dispersion process. Model profiles are also compared with lidar measurements. Results of the computer study are quite sensitive (factor of 2) to the assumed volcanic aerosol source function and the large variations in the parameterized transport between 15 and 20 km at subtropical latitudes. Sedimentation effects are uncertain by up to a factor of 1.5 because of the lack of aerosol size distribution data. The aerosol chemistry and growth, assuming that the stated mechanisms are correct, are essentially complete in several months after the eruption and cannot explain the differences between measured and modeled results.

  16. Economic Analysis of a Multi-Site Prevention Program: Assessment of Program Costs and Characterizing Site-level Variability

    PubMed Central

    Corso, Phaedra S.; Ingels, Justin B.; Kogan, Steven M.; Foster, E. Michael; Chen, Yi-Fu; Brody, Gene H.

    2013-01-01

    Programmatic cost analyses of preventive interventions commonly have a number of methodological difficulties. To determine the mean total costs and properly characterize variability, one often has to deal with small sample sizes, skewed distributions, and especially missing data. Standard approaches for dealing with missing data such as multiple imputation may suffer from a small sample size, a lack of appropriate covariates, or too few details around the method used to handle the missing data. In this study, we estimate total programmatic costs for a prevention trial evaluating the Strong African American Families-Teen program. This intervention focuses on the prevention of substance abuse and risky sexual behavior. To account for missing data in the assessment of programmatic costs we compare multiple imputation to probabilistic sensitivity analysis. The latter approach uses collected cost data to create a distribution around each input parameter. We found that with the multiple imputation approach, the mean (95% confidence interval) incremental difference was $2149 ($397, $3901). With the probabilistic sensitivity analysis approach, the incremental difference was $2583 ($778, $4346). Although the true cost of the program is unknown, probabilistic sensitivity analysis may be a more viable alternative for capturing variability in estimates of programmatic costs when dealing with missing data, particularly with small sample sizes and the lack of strong predictor variables. Further, the larger standard errors produced by the probabilistic sensitivity analysis method may signal its ability to capture more of the variability in the data, thus better informing policymakers on the potentially true cost of the intervention. PMID:23299559

  17. Economic analysis of a multi-site prevention program: assessment of program costs and characterizing site-level variability.

    PubMed

    Corso, Phaedra S; Ingels, Justin B; Kogan, Steven M; Foster, E Michael; Chen, Yi-Fu; Brody, Gene H

    2013-10-01

    Programmatic cost analyses of preventive interventions commonly have a number of methodological difficulties. To determine the mean total costs and properly characterize variability, one often has to deal with small sample sizes, skewed distributions, and especially missing data. Standard approaches for dealing with missing data such as multiple imputation may suffer from a small sample size, a lack of appropriate covariates, or too few details around the method used to handle the missing data. In this study, we estimate total programmatic costs for a prevention trial evaluating the Strong African American Families-Teen program. This intervention focuses on the prevention of substance abuse and risky sexual behavior. To account for missing data in the assessment of programmatic costs we compare multiple imputation to probabilistic sensitivity analysis. The latter approach uses collected cost data to create a distribution around each input parameter. We found that with the multiple imputation approach, the mean (95 % confidence interval) incremental difference was $2,149 ($397, $3,901). With the probabilistic sensitivity analysis approach, the incremental difference was $2,583 ($778, $4,346). Although the true cost of the program is unknown, probabilistic sensitivity analysis may be a more viable alternative for capturing variability in estimates of programmatic costs when dealing with missing data, particularly with small sample sizes and the lack of strong predictor variables. Further, the larger standard errors produced by the probabilistic sensitivity analysis method may signal its ability to capture more of the variability in the data, thus better informing policymakers on the potentially true cost of the intervention.

  18. Compendium of Post-Failure Analysis Techniques for Composite Materials.

    DTIC Science & Technology

    1987-01-01

    HHdrocarbon 285.0 Ether or alcohol 286.5 Ketone 288.0 Ester 288.8 (Ref. 5) Figure 3-37. Carbon Peak Shifts in XPS 5-B70227Rt -130 " Hydrocarbon...structure overlays composite material since neutrons are not as attenuated by metal as X-rays, and are relatively sensitive to poly - meric materials...Thermal Aging 3-18 Glass Transition Temperature Determination - 3-37 TMA Penetration Test Setup 3-19 Glass Transition Temperature Determination - 3-37 TMA

  19. Radioimmunoassay determinations of p-hydroxyphenformin and of apparent phenformin in human plasma or serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alkalay, D.; Khemani, L.; Bartlett, M.F.

    1978-01-01

    Sensitive radioimmunoassay procedures are described for measuring p-hydroxyphenformin and apparent phenformin in human plasma or serum. The p-hydroxyphenformin procedure, which requires advance phenformin analysis, offers excellent accuracy. The determinations of apparent phenformin are influenced by the phenformin and p-hydroxyphenformin contents of the samples. Over a period of four months, the methods showed a precision associated with relative standard deviations of 12% for apparent phenformin and 13% for p-hydroxyphenformin.

  20. Robust Sensitivity Analysis for the Joint Improvised Explosive Device Defeat Organization (JIEDDO) Proposal Selection Model

    DTIC Science & Technology

    2009-03-01

    making process (Skinner, 2001, 9). According to Clemen , before we can begin to apply any methodology to a specific decision problem, the analyst...it is possible to work with them to determine the values and objectives that relate to the decision in question ( Clemen , 2001, 21). Clemen ...value hierarchy is constructed, Clemen and Reilly suggest that a trade off is made between varying objectives. They introduce weights to determine

  1. Colorimetric microdetermination of captopril in pure form and in pharmaceutical formulations

    NASA Astrophysics Data System (ADS)

    Shama, Sayed Ahmed; El-Sayed Amin, Alla; Omara, Hany

    2006-11-01

    A simple, rapid, accurate, precise and sensitive colorimetric method for the determination of captopril (CAP) in bulk sample and in dosage forms is described. The method is based on oxidation of the drug by potassium permanganate in acidic medium and determination of the unreacted oxidant by measuring the decrease in absorbance for five different dyes; methylene blue (MB); acid blue 74 (AB), acid red 73 (AR), amaranth dye (AM) and acid orange 7 (AO) at a suitable λmax (660, 610, 510, 520, and 485 nm), respectively. Regression analysis of Beer's plots showed good correlation in the concentration ranges (0.4 12.5, 0.3 10, 0.5 11, 0.4 8.3 and 0.5 9.3 μg ml-1), respectively. The apparent molar absorbtivity, Sandell sensitivity, detection and quantitation limits were calculated. For more accurate results, Ringbom optimum concentration ranges were 0.5 12, 0.5 9.6, 0.6 10.5, 0.5 8.0 and 0.7 9.0 μg ml-1, respectively. The validity of the proposed method was tested by analyzing in pure and dosage forms containing CAP whether alone or in combination with hydrochlorothiazide. Statistical analysis of the results reflects that the proposed procedures are precise, accurate and easily applicable for the determination of CAP in pure form and in pharmaceutical preparations. Also, the stability constant was determined and the free energy change was calculated potentiometrically.

  2. Comparison between Surrogate Indexes of Insulin Sensitivity/Resistance and Hyperinsulinemic Euglycemic Glucose Clamps in Rhesus Monkeys

    PubMed Central

    Lee, Ho-Won; Muniyappa, Ranganath; Yan, Xu; Yue, Lilly Q.; Linden, Ellen H.; Chen, Hui; Hansen, Barbara C.

    2011-01-01

    The euglycemic glucose clamp is the reference method for assessing insulin sensitivity in humans and animals. However, clamps are ill-suited for large studies because of extensive requirements for cost, time, labor, and technical expertise. Simple surrogate indexes of insulin sensitivity/resistance including quantitative insulin-sensitivity check index (QUICKI) and homeostasis model assessment (HOMA) have been developed and validated in humans. However, validation studies of QUICKI and HOMA in both rats and mice suggest that differences in metabolic physiology between rodents and humans limit their value in rodents. Rhesus monkeys are a species more similar to humans than rodents. Therefore, in the present study, we evaluated data from 199 glucose clamp studies obtained from a large cohort of 86 monkeys with a broad range of insulin sensitivity. Data were used to evaluate simple surrogate indexes of insulin sensitivity/resistance (QUICKI, HOMA, Log HOMA, 1/HOMA, and 1/Fasting insulin) with respect to linear regression, predictive accuracy using a calibration model, and diagnostic performance using receiver operating characteristic. Most surrogates had modest linear correlations with SIClamp (r ≈ 0.4–0.64) with comparable correlation coefficients. Predictive accuracy determined by calibration model analysis demonstrated better predictive accuracy of QUICKI than HOMA and Log HOMA. Receiver operating characteristic analysis showed equivalent sensitivity and specificity of most surrogate indexes to detect insulin resistance. Thus, unlike in rodents but similar to humans, surrogate indexes of insulin sensitivity/resistance including QUICKI and log HOMA may be reasonable to use in large studies of rhesus monkeys where it may be impractical to conduct glucose clamp studies. PMID:21209021

  3. A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer.

    PubMed

    Huebner, R H; Park, K C; Shepherd, J E; Schwimmer, J; Czernin, J; Phelps, M E; Gambhir, S S

    2000-07-01

    A meta-analysis of the literature for the use of FDG PET in the detection of recurrent colorectal cancer (CRC) was conducted to evaluate the quality of the reported studies. Overall values for the sensitivity and specificity of whole-body FDG PET and an overall FDG PET-directed percentage change in management were also determined through this analysis. Guidelines to evaluate the articles were formulated on the basis of the U.S. medical payer source criteria for assessing studies that report information on usage of new medical technology. A metaanalysis was conducted using methodology described in the peer-reviewed literature. On the basis of the guidelines established for our review, the availability of necessary information for assessing the reliability of the FDG PET data for diagnosing recurrent CRC was less than ideal. Through a meta-analysis of 11 articles, we determined, within a 95% confidence level, an overall sensitivity of 97% (95% confidence level, 95%-99%) and an overall specificity of 76% (95% confidence level, 64%-88%) for FDG PET detecting recurrent CRC throughout the whole body. Furthermore, through pooling of the change-in-management data, an overall FDG PET-directed change in management was calculated to be 29% (95% confidence level, 25%-34%). Our review suggests that improvements can be made to more effectively report the results of these FDG PET studies. The overall values determined through the meta-analysis indicate the potential benefits of using FDG PET as a diagnostic or management tool. Furthermore, these values should prove to be useful to assess the cost-effectiveness of using FDG PET in the management of patients with recurrent CRC.

  4. Continuous flow analysis combined with a light-absorption ratio variation approach for determination of copper at ng/ml level in natural water.

    PubMed

    Gao, Hong-Wen; Wang, Chun-Lei; Jia, Jiang-Yan; Zhang, Ya-Lei

    2007-06-01

    The complexation between Cu(II) and naphthochrome green (NG) is very sensitive at pH 4.09 with the formation of complex ion [Cu(NG)2(H2O)2](2-). It can thus used for the determination of Cu(II) by the light-absorption ratio variation approach (LARVA) with a good selectivity. Both the ordinary detection procedure and continuous flow analysis (CFA) were carried out, where the latter is fit for continuous and rapid analysis of samples. The limit of detection (LOD) of Cu(II) is only 1 ng/ml, which is favorable for direct monitoring of natural water. About 30 samples could be analyzed per hour by CFA. Cu(II) contents in Yangtze River, West Lake, Taihu Lake of China and seawater near Shanghai were determined with satisfactory results. The CFA-LARVA spectrophotometry was the first to be coupled and it will play an important role in the in-situ analysis of natural water quality.

  5. Sensitivity analysis in a life cycle assessment of an aged red wine production from Catalonia, Spain.

    PubMed

    Meneses, M; Torres, C M; Castells, F

    2016-08-15

    Sustainability in agriculture and food processing is an issue with a clear growing interest; especially in products were consumers have particular awareness regarding its environmental profile. This is the case of wine industry depending on grape production, winemaking and bottling. Also viticulture and generally agricultural production is significantly affected by climate variations. The aim of this article is to determine the environmental load of an aged red wine from a winery in Catalonia, Spain, over its entire life cycle, including sensitivity analysis of the main parameters related to the cultivation, vinification and bottling. The life cycle assessment (LCA) methodology is used for the environmental analysis. In a first step, life cycle inventory (LCI) data were collected by questionnaires and interviews with the winemaker, all data are actual operating data and all the stages involved in the production have been taken into account (viticulture, vinification, bottling and the disposal subsystem). Data were then used to determine the environmental profile by a life cycle impact assessment using the ReCiPe method. Annual variability in environmental performance, stresses the importance of including timeline analysis in the wine sector. Because of that this study is accompanied with a sensitivity analysis carried out by a Monte Carlo simulation that takes into account the uncertainty and variability of the parameters used. In this manner, the results are presented with confidence intervals to provide a wider view of the environmental issues derived from the activities of the studied wine estate regardless of the eventualities of a specific harvesting year. Since the beverage packaging has an important influence in this case, a dataset for the production of green glass was adapted to reflect the actual recycling situation in Spain. Furthermore, a hypothetical variation of the glass-recycling rate in the glass production completes this article, as a key variable of sensitivity analysis, in order… in order to show the potential reduction of total greenhouse gas emissions. It was found that in almost all categories the production of the glass bottles has the highest environmental impact (10%-80% depending on the impact category) followed by the viticulture stage, i.e. the agricultural activities (17%-84% depending on the impact category). The vinification step, i.e. the winemaking itself, has an almost negligible effect on the overall load (1%-5%). The sensitivity analysis showed that the results do not differ by more than ±4% from the expected values except for the water depletion indicator. With the variation of the recycling rate, it could be shown that an increase in the rate from 60% to 85% allows for a reduction of 102gCO2eq. per bottle (-11.1%). The results show that glass production causes the highest environmental load. The key parameters that determine the impact are the recycling rate and the bottle weight. A glass container deposit legislation might be a promising way to enhance the glass recycling. Lightweight bottles and alternative packaging should also be considered. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Budget impact analysis of pemetrexed introduction: case study from a teaching hospital perspective, Thailand.

    PubMed

    Chanjaruporn, Farsai; Roughead, Elizabeth E; Sooksriwong, Cha-oncin; Kaojarern, Sming

    2011-09-01

    Thailand does not currently require Budget Impact Analysis (BIA) assessment. The present study aimed to estimate the annual drug cost and the incremental impact on the hospital pharmaceutical budget of the introduction of pemetrexed to a Thai teaching hospital. The budget impact model was conducted in accordance with the Guidelines for preparing submissions to the Pharmaceutical Benefits Advisory Committee (PBAC). The model variables consisted of number of patients, growth rate of lung cancer, uptake rate of pemetrexed over time, unit prices of drugs, and the length and cost of treatment. Sensitivity analysis was performed to determine changes in budgetary impact due to variation of parameters or assumptions in the model. The introduction of pemetrexed was estimated to cause considerable costs for the teaching hospital. In the base-case analysis, the incremental costs were estimated at 8,553,984 Baht in the first year increasing to 12, 118, 144 Baht, 17,820,800 Baht and 17,820,800 Baht in the following years. The 4-year net budgetary impact was 20,154,480 Baht or approximately 127,560 Baht per patient. Sensitivity analyses found that number of treatment cycles andproportion of patients assumed to be treated with pemetrexed were the two most important influencing factors in the model. New costly innovative interventions should be evaluated using the BIA model to determine whether they are affordable. The Thai government should consider requiring the BIA study as one of the requirements for drug submission to assist in the determination of listing and subsidizing decision for medicines.

  7. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    NASA Astrophysics Data System (ADS)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c

  8. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis.

    PubMed

    Liu, C Carrie; Jethwa, Ashok R; Khariwala, Samir S; Johnson, Jonas; Shin, Jennifer J

    2016-01-01

    (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of nondiagnostic and indeterminate cytology with parotid FNA. Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I(2) statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I(2) point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509-0.982) and a specificity of 0.995 (95% CI, 0.960-0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030-0.075) and 0.147 (95% CI, 0.106-0.188), respectively. FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  9. Sensitivity, Specificity, and Posttest Probability of Parotid Fine-Needle Aspiration: A Systematic Review and Meta-analysis

    PubMed Central

    Liu, C. Carrie; Jethwa, Ashok R.; Khariwala, Samir S.; Johnson, Jonas; Shin, Jennifer J.

    2016-01-01

    Objectives (1) To analyze the sensitivity and specificity of fine-needle aspiration (FNA) in distinguishing benign from malignant parotid disease. (2) To determine the anticipated posttest probability of malignancy and probability of non-diagnostic and indeterminate cytology with parotid FNA. Data Sources Independently corroborated computerized searches of PubMed, Embase, and Cochrane Central Register were performed. These were supplemented with manual searches and input from content experts. Review Methods Inclusion/exclusion criteria specified diagnosis of parotid mass, intervention with both FNA and surgical excision, and enumeration of both cytologic and surgical histopathologic results. The primary outcomes were sensitivity, specificity, and posttest probability of malignancy. Heterogeneity was evaluated with the I2 statistic. Meta-analysis was performed via a 2-level mixed logistic regression model. Bayesian nomograms were plotted via pooled likelihood ratios. Results The systematic review yielded 70 criterion-meeting studies, 63 of which contained data that allowed for computation of numerical outcomes (n = 5647 patients; level 2a) and consideration of meta-analysis. Subgroup analyses were performed in studies that were prospective, involved consecutive patients, described the FNA technique utilized, and used ultrasound guidance. The I2 point estimate was >70% for all analyses, except within prospectively obtained and ultrasound-guided results. Among the prospective subgroup, the pooled analysis demonstrated a sensitivity of 0.882 (95% confidence interval [95% CI], 0.509–0.982) and a specificity of 0.995 (95% CI, 0.960–0.999). The probabilities of nondiagnostic and indeterminate cytology were 0.053 (95% CI, 0.030–0.075) and 0.147 (95% CI, 0.106–0.188), respectively. Conclusion FNA has moderate sensitivity and high specificity in differentiating malignant from benign parotid lesions. Considerable heterogeneity is present among studies. PMID:26428476

  10. Quantifying the sensitivity of feedstock properties and process conditions on hydrochar yield, carbon content, and energy content.

    PubMed

    Li, Liang; Wang, Yiying; Xu, Jiting; Flora, Joseph R V; Hoque, Shamia; Berge, Nicole D

    2018-08-01

    Hydrothermal carbonization (HTC) is a wet, low temperature thermal conversion process that continues to gain attention for the generation of hydrochar. The importance of specific process conditions and feedstock properties on hydrochar characteristics is not well understood. To evaluate this, linear and non-linear models were developed to describe hydrochar characteristics based on data collected from HTC-related literature. A Sobol analysis was subsequently conducted to identify parameters that most influence hydrochar characteristics. Results from this analysis indicate that for each investigated hydrochar property, the model fit and predictive capability associated with the random forest models is superior to both the linear and regression tree models. Based on results from the Sobol analysis, the feedstock properties and process conditions most influential on hydrochar yield, carbon content, and energy content were identified. In addition, a variational process parameter sensitivity analysis was conducted to determine how feedstock property importance changes with process conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. The Contribution of Particle Swarm Optimization to Three-Dimensional Slope Stability Analysis

    PubMed Central

    A Rashid, Ahmad Safuan; Ali, Nazri

    2014-01-01

    Over the last few years, particle swarm optimization (PSO) has been extensively applied in various geotechnical engineering including slope stability analysis. However, this contribution was limited to two-dimensional (2D) slope stability analysis. This paper applied PSO in three-dimensional (3D) slope stability problem to determine the critical slip surface (CSS) of soil slopes. A detailed description of adopted PSO was presented to provide a good basis for more contribution of this technique to the field of 3D slope stability problems. A general rotating ellipsoid shape was introduced as the specific particle for 3D slope stability analysis. A detailed sensitivity analysis was designed and performed to find the optimum values of parameters of PSO. Example problems were used to evaluate the applicability of PSO in determining the CSS of 3D slopes. The first example presented a comparison between the results of PSO and PLAXI-3D finite element software and the second example compared the ability of PSO to determine the CSS of 3D slopes with other optimization methods from the literature. The results demonstrated the efficiency and effectiveness of PSO in determining the CSS of 3D soil slopes. PMID:24991652

  12. The contribution of particle swarm optimization to three-dimensional slope stability analysis.

    PubMed

    Kalatehjari, Roohollah; Rashid, Ahmad Safuan A; Ali, Nazri; Hajihassani, Mohsen

    2014-01-01

    Over the last few years, particle swarm optimization (PSO) has been extensively applied in various geotechnical engineering including slope stability analysis. However, this contribution was limited to two-dimensional (2D) slope stability analysis. This paper applied PSO in three-dimensional (3D) slope stability problem to determine the critical slip surface (CSS) of soil slopes. A detailed description of adopted PSO was presented to provide a good basis for more contribution of this technique to the field of 3D slope stability problems. A general rotating ellipsoid shape was introduced as the specific particle for 3D slope stability analysis. A detailed sensitivity analysis was designed and performed to find the optimum values of parameters of PSO. Example problems were used to evaluate the applicability of PSO in determining the CSS of 3D slopes. The first example presented a comparison between the results of PSO and PLAXI-3D finite element software and the second example compared the ability of PSO to determine the CSS of 3D slopes with other optimization methods from the literature. The results demonstrated the efficiency and effectiveness of PSO in determining the CSS of 3D soil slopes.

  13. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  14. The use of intraoperative triggered electromyography to detect misplaced pedicle screws: a systematic review and meta-analysis.

    PubMed

    Mikula, Anthony L; Williams, Seth K; Anderson, Paul A

    2016-04-01

    Insertion of instruments or implants into the spine carries a risk for injury to neural tissue. Triggered electromyography (tEMG) is an intraoperative neuromonitoring technique that involves electrical stimulation of a tool or screw and subsequent measurement of muscle action potentials from myotomes innervated by nerve roots near the stimulated instrument. The authors of this study sought to determine the ability of tEMG to detect misplaced pedicle screws (PSs). The authors searched the U.S. National Library of Medicine, the Web of Science Core Collection database, and the Cochrane Central Register of Controlled Trials for PS studies. A meta-analysis of these studies was performed on a per-screw basis to determine the ability of tEMG to detect misplaced PSs. Sensitivity, specificity, and receiver operating characteristic (ROC) area under the curve (AUC) were calculated overall and in subgroups. Twenty-six studies were included in the systematic review. The authors analyzed 18 studies in which tEMG was used during PS placement in the meta-analysis, representing data from 2932 patients and 15,065 screws. The overall sensitivity of tEMG for detecting misplaced PSs was 0.78, and the specificity was 0.94. The overall ROC AUC was 0.96. A tEMG current threshold of 10-12 mA (ROC AUC 0.99) and a pulse duration of 300 µsec (ROC AUC 0.97) provided the most accurate testing parameters for detecting misplaced screws. Screws most accurately conducted EMG signals (ROC AUC 0.98). Triggered electromyography has very high specificity but only fair sensitivity for detecting malpositioned PSs.

  15. High-throughput determination of vancomycin in human plasma by a cost-effective system of two-dimensional liquid chromatography.

    PubMed

    Sheng, Yanghao; Zhou, Boting

    2017-05-26

    Therapeutic drug monitoring (TDM) is one of the most important services of clinical laboratories. Two main techniques are commonly used: the immunoassay and chromatography method. We have developed a cost-effective system of two-dimensional liquid chromatography with ultraviolet detection (2D-LC-UV) for high-throughput determination of vancomycin in human plasma that combines the automation and low start-up costs of the immunoassay with the high selectivity and sensitivity of the liquid chromatography coupled with mass spectrometric detection without incurring their disadvantages, achieving high cost-effectiveness. This 2D-LC system offers a large volume injection to provide sufficient sensitivity and uses simulated gradient peak compression technology to control peak broadening and to improve peak shape. A middle column was added to reduce the analysis cycle time and make it suitable for high-throughput routine clinical assays. The analysis cycle time was 4min and the peak width was 0.8min. Compared with other chromatographic methods that have been developed, the analysis cycle time and peak width for vancomycin was reduced significantly. The lower limit of quantification was 0.20μg/mL for vancomycin, which is the same as certain LC-MS/MS methods that have been recently developed and validated. The method is rapid, automated, and low-cost and has high selectivity and sensitivity for the quantification of vancomycin in human plasma, thus making it well-suited for use in hospital clinical laboratories. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. 75 FR 28616 - Agilent Technologies, Inc.; Analysis of the Agreement Containing Consent Order to Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ... equipment used to test cell phones and communications equipment, machines that determine the contents of... employ various analytical techniques to test samples of many types, are used by academic researchers... require the sensitivity provided by ICP-MS, and because many customers perform tests pursuant to...

  17. USE OF WHOLE BODY CHEMICAL RESIDUE ANALYSIS AND LASER SCREENING CONFOCAL MICROSCOPY TO DESCRIBE DISTRIBUTION OF PBTS IN FISH EARLY LIFE STAGES

    EPA Science Inventory

    Fish early life stages (ELS) are more sensitive than juveniles or adults to many persistent bioaccumulative toxicants (PBTs). To better understand the mechanisms by which these chemicals produce toxicity during fish ELS, dose-response relationships need to be determined in relat...

  18. Field test and sensitivity analysis of a sensible heat balance method to determine ice contents

    USDA-ARS?s Scientific Manuscript database

    Soil ice content impacts winter vadose zone hydrology. It may be possible to estimate changes in soil ice content with a sensible heat balance (SHB) method, using measurements from heat pulse (HP) sensors. Feasibility of the SHB method is unknown because of difficulties in measuring soil thermal pro...

  19. Sensitivity of FIA Volume Estimates to Changes in Stratum Weights and Number of Strata

    Treesearch

    James A. Westfall; Michael Hoppus

    2005-01-01

    In the Northeast region, the USDA Forest Service Forest Inventory and Analysis (FIA) program utilizes stratified sampling techniques to improve the precision of population estimates. Recently, interpretation of aerial photographs was replaced with classified remotely sensed imagery to determine stratum weights and plot stratum assignments. However, stratum weights...

  20. High-throughput analysis of sulfatides in cerebrospinal fluid using automated extraction and UPLC-MS/MS.

    PubMed

    Blomqvist, Maria; Borén, Jan; Zetterberg, Henrik; Blennow, Kaj; Månsson, Jan-Eric; Ståhlman, Marcus

    2017-07-01

    Sulfatides (STs) are a group of glycosphingolipids that are highly expressed in brain. Due to their importance for normal brain function and their potential involvement in neurological diseases, development of accurate and sensitive methods for their determination is needed. Here we describe a high-throughput oriented and quantitative method for the determination of STs in cerebrospinal fluid (CSF). The STs were extracted using a fully automated liquid/liquid extraction method and quantified using ultra-performance liquid chromatography coupled to tandem mass spectrometry. With the high sensitivity of the developed method, quantification of 20 ST species from only 100 μl of CSF was performed. Validation of the method showed that the STs were extracted with high recovery (90%) and could be determined with low inter- and intra-day variation. Our method was applied to a patient cohort of subjects with an Alzheimer's disease biomarker profile. Although the total ST levels were unaltered compared with an age-matched control group, we show that the ratio of hydroxylated/nonhydroxylated STs was increased in the patient cohort. In conclusion, we believe that the fast, sensitive, and accurate method described in this study is a powerful new tool for the determination of STs in clinical as well as preclinical settings. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.

  1. Inorganic selenium speciation analysis in Allium and Brassica vegetables by ionic liquid assisted liquid-liquid microextraction with multivariate optimization.

    PubMed

    Castro Grijalba, Alexander; Martinis, Estefanía M; Wuilloud, Rodolfo G

    2017-03-15

    A highly sensitive vortex assisted liquid-liquid microextraction (VA-LLME) method was developed for inorganic Se [Se(IV) and Se(VI)] speciation analysis in Allium and Brassica vegetables. Trihexyl(tetradecyl)phosphonium decanoate phosphonium ionic liquid (IL) was applied for the extraction of Se(IV)-ammonium pyrrolidine dithiocarbamate (APDC) complex followed by Se determination with electrothermal atomic absorption spectrometry. A complete optimization of the graphite furnace temperature program was developed for accurate determination of Se in the IL-enriched extracts and multivariate statistical optimization was performed to define the conditions for the highest extraction efficiency. Significant factors of IL-VA-LLME method were sample volume, extraction pH, extraction time and APDC concentration. High extraction efficiency (90%), a 100-fold preconcentration factor and a detection limit of 5.0ng/L were achieved. The high sensitivity obtained with preconcentration and the non-chromatographic separation of inorganic Se species in complex matrix samples such as garlic, onion, leek, broccoli and cauliflower, are the main advantages of IL-VA-LLME. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Disposable pipette extraction for gas chromatographic determination of codeine, morphine, and 6-monoacetylmorphine in vitreous humor.

    PubMed

    Kovatsi, Leda; Rentifis, Konstantinos; Giannakis, Dimitrios; Njau, Samuel; Samanidou, Victoria

    2011-07-01

    The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Ordinal patterns in epileptic brains: Analysis of intracranial EEG and simultaneous EEG-fMRI

    NASA Astrophysics Data System (ADS)

    Rummel, C.; Abela, E.; Hauf, M.; Wiest, R.; Schindler, K.

    2013-06-01

    Epileptic seizures are associated with high behavioral stereotypy of the patients. In the EEG of epilepsy patients characteristic signal patterns can be found during and between seizures. Here we use ordinal patterns to analyze EEGs of epilepsy patients and quantify the degree of signal determinism. Besides relative signal redundancy and the fraction of forbidden patterns we introduce the fraction of under-represented patterns as a new measure. Using the logistic map, parameter scans are performed to explore the sensitivity of the measures to signal determinism. Thereafter, application is made to two types of EEGs recorded in two epilepsy patients. Intracranial EEG shows pronounced determinism peaks during seizures. Finally, we demonstrate that ordinal patterns may be useful for improving analysis of non-invasive simultaneous EEG-fMRI.

  4. Processing companies' preferences for attributes of beef in Switzerland.

    PubMed

    Boesch, Irene

    2014-01-01

    The aim of this work was to assess processing companies' preferences for attributes of Swiss beef. To this end, qualitative interviews were used to derive product attributes that determine the buying decision. Through an adaptive-choice based conjoint analysis survey and latent class analysis of choice data, we compute class preferences. Results show that there are two distinct classes. A smaller class emphasizes traceability back to the birth farm and low producer price, a larger class focuses on environmental effects and origin. Additionally we see that larger companies are more price-sensitive and smaller companies are more sensitive to origin of the animals. The results outlined in this paper may be used to target market segments and to derive differentiation strategies based on product characteristics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Prediction of sensitivity to warfarin based on VKORC1 and CYP2C9 polymorphisms in patients from different places in Colombia.

    PubMed

    Cifuentes, Ricardo A; Murillo-Rojas, Juan; Avella-Vargas, Esperanza

    2016-03-03

    In the search to prevent hemorrhages associated with anticoagulant therapy, a major goal is to validate predictors of sensitivity to warfarin. However, previous studies in Colombia that included polymorphisms in the VKORC1 and CYP2C9 genes as predictors reported different algorithm performances to explain dose variations, and did not evaluate the prediction of sensitivity to warfarin.  To determine the accuracy of the pharmacogenetic analysis, which includes the CYP2C9 *2 and *3 and VKORC1 1639G>A polymorphisms in predicting patients' sensitivity to warfarin at the Hospital Militar Central, a reference center for patients born in different parts of Colombia.  Demographic and clinical data were obtained from 130 patients with stable doses of warfarin for more than two months. Next, their genotypes were obtained through a melting curve analysis. After verifying the Hardy-Weinberg equilibrium of the genotypes from the polymorphisms, a statistical analysis was done, which included multivariate and predictive approaches.  A pharmacogenetic model that explained 52.8% of dose variation (p<0.001) was built, which was only 4% above the performance resulting from the same data using the International Warfarin Pharmacogenetics Consortium algorithm. The model predicting the sensitivity achieved an accuracy of 77.8% and included age (p=0.003), polymorphisms *2 and *3 (p=0.002) and polymorphism 1639G>A (p<0.001) as predictors.  These results in a mixed population support the prediction of sensitivity to warfarin based on polymorphisms in VKORC1 and CYP2C9 as a valid approach in Colombian patients.

  6. The art of maturity modeling. Part 2. Alternative models and sensitivity analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waples, D.W.; Suizu, Masahiro; Kamata, Hiromi

    1992-01-01

    The sensitivity of exploration decisions to variations in several input parameters for maturity modeling was examined for the MITI Rumoi well, Hokkaido, Japan. Decisions were almost completely insensitive to uncertainties about formation age and erosional removal across some unconformities, but were more sensitive to changes in removal during unconformities which occurred near maximum paleotemperatures. Exploration decisions were not very sensitive to the choice of a particular kinetic model for hydrocarbon generation. Uncertainties in kerogen type and the kinetics of different kerogen types are more serious than differences among the various kinetic models. Results of modeling using the TTI method weremore » unsatisfactory. Thermal history and timing and amount of hydrocarbon generation estimated or calculated using the TTI method were greatly different from those obtained using a purely kinetic model. The authors strongly recommend use of the kinetic R{sub o} method instead of the TTI method. If they had lacked measured R{sub o} data, subsurface temperature data, or both, their confidence in the modeling results would have been sharply reduced. Conceptual models for predicting heat flow and thermal conductivity are simply too weak at present to allow one to carry out highly meaningful modeling unless the input is constrained by measured data. Maturity modeling therefore requires the use of more, not fewer, measured temperature and maturity data. The use of sensitivity analysis in maturity modeling is very important for understanding the geologic system, for knowing what level of confidence to place on the results, and for determining what new types of data would be most necessary to improve confidence. Sensitivity analysis can be carried out easily using a rapid, interactive maturity-modeling program.« less

  7. Improvement of sensitivity in PIGE analysis of steels by neutron-gamma coincidences measurement

    NASA Astrophysics Data System (ADS)

    Ene, Antoaneta

    2004-07-01

    In this work the sensitivities of minor elements in a standard steel sample EURONORM-CRM No. 085-1 irradiated with beams of 5.5 MeV protons and 5 MeV deuterons have been determined both by regular proton- (p-PIGE) and deuteron-induced prompt gamma-ray emission (d-PIGE) methods and with the selection of the (p, n) and (d, n) reaction channels, measuring the neutron-gamma coincidences. A check on the elemental composition of the steel standard has also been carried out using combined INAA and PIXE and quantitative determinations have been done for some elements whose concentrations were not specified by the manufacturer, such as Al, As, Cr, Mo, Na, Ni, W. This complex study has resulted in a significant improvement of the sensitivities for some minor elements in steel by reducing the background and increasing the peak-to-background ratio in the coincident prompt gamma-rays spectra as a result of the elimination of the competing nuclear reactions originating from isotopes of the adjacent elements in the periodic table, present in the steel target. This extension of the PIGE method could be adapted by any analyst with the necessary equipment for the analysis of a wide variety of matrices that are refractory enough to withstand the heating effect of the bombarding beam, taking into account that this type of experiment requires longer irradiation times.

  8. Logit and probit model in toll sensitivity analysis of Solo-Ngawi, Kartasura-Palang Joglo segment based on Willingness to Pay (WTP)

    NASA Astrophysics Data System (ADS)

    Handayani, Dewi; Cahyaning Putri, Hera; Mahmudah, AMH

    2017-12-01

    Solo-Ngawi toll road project is part of the mega project of the Trans Java toll road development initiated by the government and is still under construction until now. PT Solo Ngawi Jaya (SNJ) as the Solo-Ngawi toll management company needs to determine the toll fare that is in accordance with the business plan. The determination of appropriate toll rates will affect progress in regional economic sustainability and decrease the traffic congestion. These policy instruments is crucial for achieving environmentally sustainable transport. Therefore, the objective of this research is to find out how the toll fare sensitivity of Solo-Ngawi toll road based on Willingness To Pay (WTP). Primary data was obtained by distributing stated preference questionnaires to four wheeled vehicle users in Kartasura-Palang Joglo artery road segment. Further data obtained will be analysed with logit and probit model. Based on the analysis, it is found that the effect of fare change on the amount of WTP on the binomial logit model is more sensitive than the probit model on the same travel conditions. The range of tariff change against values of WTP on the binomial logit model is 20% greater than the range of values in the probit model . On the other hand, the probability results of the binomial logit model and the binary probit have no significant difference (less than 1%).

  9. Sensitivity of UV Erythemal Radiation to Total Ozone Changes under Different Sky Conditions: Results for Granada, Spain.

    PubMed

    Antón, Manuel; Cazorla, Alberto; Mateos, David; Costa, Maria J; Olmo, Francisco J; Alados-Arboledas, Lucas

    2016-01-01

    This study focuses on the analysis of the sensitivity of UV erythemal radiation (UVER) to variations in the total ozone column (TOC) under different sky conditions at Granada (southeastern Spain). The sensitivity is studied both in relative terms by means of the Radiation Amplification Factor (RAF) and in absolute terms using the Ozone Efficiency (OE). These two variables are determined for diverse sky conditions characterized by the cloud cover information given by a sky camera (in oktas) and the cloud optical depth (COD) estimated from global solar radiation measurements. As expected, in absolute terms, the TOC variations cause substantially smaller UVER changes during completely overcast situations than during cloud-free cases. For instance, the OE (SZA = 30°, TOC = 290 DU) decreases from 0.68 mW m(-2) per unit of TOC (0 oktas) to 0.50 mW m(-2) per unit of TOC (8 oktas). However, the opposite is observed when the analysis is performed in relative terms. Thus, the RAF (determined for SZA cases below 80°) increases from 1.1 for cloud-free cases (0 oktas) to 1.4 for completely overcast situations (8 oktas). This opposite behavior is also found when both RAF and OE are analyzed as functions of COD. Thus, while the OE strongly decreases with increasing COD, the RAF increases as COD increases. © 2015 The American Society of Photobiology.

  10. UTI diagnosis and antibiogram using Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Kastanos, Evdokia; Kyriakides, Alexandros; Hadjigeorgiou, Katerina; Pitris, Constantinos

    2009-07-01

    Urinary tract infection diagnosis and antibiogram require a 48 hour waiting period using conventional methods. This results in ineffective treatments, increased costs and most importantly in increased resistance to antibiotics. In this work, a novel method for classifying bacteria and determining their sensitivity to an antibiotic using Raman spectroscopy is described. Raman spectra of three species of gram negative Enterobacteria, most commonly responsible for urinary tract infections, were collected. The study included 25 samples each of E.coli, Klebsiella p. and Proteus spp. A novel algorithm based on spectral ratios followed by discriminant analysis resulted in classification with over 94% accuracy. Sensitivity and specificity for the three types of bacteria ranged from 88-100%. For the development of an antibiogram, bacterial samples were treated with the antibiotic ciprofloxacin to which they were all sensitive. Sensitivity to the antibiotic was evident after analysis of the Raman signatures of bacteria treated or not treated with this antibiotic as early as two hours after exposure. This technique can lead to the development of new technology for urinary tract infection diagnosis and antibiogram with same day results, bypassing urine cultures and avoiding all undesirable consequences of current practice.

  11. Urinary tract infection diagnosis and response to antibiotics using Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Kastanos, Evdokia; Kyriakides, Alexandros; Hadjigeorgiou, Katerina; Pitris, Constantinos

    2009-02-01

    Urinary tract infection diagnosis and antibiogram require a 48 hour waiting period using conventional methods. This results in ineffective treatments, increased costs and most importantly in increased resistance to antibiotics. In this work, a novel method for classifying bacteria and determining their sensitivity to an antibiotic using Raman spectroscopy is described. Raman spectra of three species of gram negative Enterobacteria, most commonly responsible for urinary tract infections, were collected. The study included 25 samples each of E.coli, Klebsiella p. and Proteus spp. A novel algorithm based on spectral ratios followed by discriminant analysis resulted in classification with over 94% accuracy. Sensitivity and specificity for the three types of bacteria ranged from 88-100%. For the development of an antibiogram, bacterial samples were treated with the antibiotic ciprofloxacin to which they were all sensitive. Sensitivity to the antibiotic was evident after analysis of the Raman signatures of bacteria treated or not treated with this antibiotic as early as two hours after exposure. This technique can lead to the development of new technology for urinary tract infection diagnosis and antibiogram with same day results, bypassing urine cultures and avoiding all undesirable consequences of current practice.

  12. Assessing direct analysis in real-time-mass spectrometry (DART-MS) for the rapid identification of additives in food packaging.

    PubMed

    Ackerman, L K; Noonan, G O; Begley, T H

    2009-12-01

    The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.

  13. Selecting focal species as surrogates for imperiled species using relative sensitivities derived from occupancy analysis

    USGS Publications Warehouse

    Silvano, Amy; Guyer, Craig; Steury, Todd; Grand, James B.

    2017-01-01

    Most imperiled species are rare or elusive and difficult to detect, which makes gathering data to estimate their response to habitat restoration a challenge. We used a repeatable, systematic method for selecting focal species using relative sensitivities derived from occupancy analysis. Our objective was to select suites of focal species that would be useful as surrogates when predicting effects of restoration of habitat characteristics preferred by imperiled species. We developed 27 habitat profiles that represent general habitat relationships for 118 imperiled species. We identified 23 regularly encountered species that were sensitive to important aspects of those profiles. We validated our approach by examining the correlation between estimated probabilities of occupancy for species of concern and focal species selected using our method. Occupancy rates of focal species were more related to occupancy rates of imperiled species when they were sensitive to more of the parameters appearing in profiles of imperiled species. We suggest that this approach can be an effective means of predicting responses by imperiled species to proposed management actions. However, adequate monitoring will be required to determine the effectiveness of using focal species to guide management actions.

  14. A Sensitivity Analysis Method to Study the Behavior of Complex Process-based Models

    NASA Astrophysics Data System (ADS)

    Brugnach, M.; Neilson, R.; Bolte, J.

    2001-12-01

    The use of process-based models as a tool for scientific inquiry is becoming increasingly relevant in ecosystem studies. Process-based models are artificial constructs that simulate the system by mechanistically mimicking the functioning of its component processes. Structurally, a process-based model can be characterized, in terms of its processes and the relationships established among them. Each process comprises a set of functional relationships among several model components (e.g., state variables, parameters and input data). While not encoded explicitly, the dynamics of the model emerge from this set of components and interactions organized in terms of processes. It is the task of the modeler to guarantee that the dynamics generated are appropriate and semantically equivalent to the phenomena being modeled. Despite the availability of techniques to characterize and understand model behavior, they do not suffice to completely and easily understand how a complex process-based model operates. For example, sensitivity analysis studies model behavior by determining the rate of change in model output as parameters or input data are varied. One of the problems with this approach is that it considers the model as a "black box", and it focuses on explaining model behavior by analyzing the relationship input-output. Since, these models have a high degree of non-linearity, understanding how the input affects an output can be an extremely difficult task. Operationally, the application of this technique may constitute a challenging task because complex process-based models are generally characterized by a large parameter space. In order to overcome some of these difficulties, we propose a method of sensitivity analysis to be applicable to complex process-based models. This method focuses sensitivity analysis at the process level, and it aims to determine how sensitive the model output is to variations in the processes. Once the processes that exert the major influence in the output are identified, the causes of its variability can be found. Some of the advantages of this approach are that it reduces the dimensionality of the search space, it facilitates the interpretation of the results and it provides information that allows exploration of uncertainty at the process level, and how it might affect model output. We present an example using the vegetation model BIOME-BGC.

  15. Determination of Silicon in Hydrazine

    NASA Technical Reports Server (NTRS)

    McClure, Mark B.; Mast, Dion; Greene, Ben; Maes, Miguel J.

    2006-01-01

    Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

  16. Simultaneous determination of vitamin B12 and its derivatives using some of multivariate calibration 1 (MVC1) techniques

    NASA Astrophysics Data System (ADS)

    Samadi-Maybodi, Abdolraouf; Darzi, S. K. Hassani Nejad

    2008-10-01

    Resolution of binary mixtures of vitamin B12, methylcobalamin and B12 coenzyme with minimum sample pre-treatment and without analyte separation has been successfully achieved by methods of partial least squares algorithm with one dependent variable (PLS1), orthogonal signal correction/partial least squares (OSC/PLS), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV-vis spectra. The UV-vis spectra of the vitamin B12, methylcobalamin and B12 coenzyme were recorded in the same spectral conditions. The method of central composite design was used in the ranges of 10-80 mg L -1 for vitamin B12 and methylcobalamin and 20-130 mg L -1 for B12 coenzyme. The models refinement procedure and validation were performed by cross-validation. The minimum root mean square error of prediction (RMSEP) was 2.26 mg L -1 for vitamin B12 with PLS1, 1.33 mg L -1 for methylcobalamin with OSC/PLS and 3.24 mg L -1 for B12 coenzyme with HLA techniques. Figures of merit such as selectivity, sensitivity, analytical sensitivity and LOD were determined for three compounds. The procedure was successfully applied to simultaneous determination of three compounds in synthetic mixtures and in a pharmaceutical formulation.

  17. Effect of hypothyroidism on insulin sensitivity and glucose tolerance in dogs.

    PubMed

    Hofer-Inteeworn, Natalie; Panciera, David L; Monroe, William E; Saker, Korinn E; Davies, Rebecca Hegstad; Refsal, Kent R; Kemnitz, Joseph W

    2012-04-01

    To determine the effects of hypothyroidism on insulin sensitivity, glucose tolerance, and concentrations of hormones counter-regulatory to insulin in dogs. 8 anestrous mixed-breed bitches with experimentally induced hypothyroidism and 8 euthyroid control dogs. The insulin-modified frequently sampled IV glucose tolerance test and minimal model analysis were used to determine basal plasma insulin and glucose concentrations, acute insulin response to glucose, insulin sensitivity, glucose effectiveness, and disposition index. Growth hormone response was assessed by stimulation and suppression tests. Additionally, basal serum growth hormone (GH) and insulin-like growth factor-1 (IGF-1) concentrations and urine cortisol-to-creatinine concentration ratios were measured and dual energy x-ray absorptiometry was performed to evaluate body composition. Insulin sensitivity was lower in the hypothyroid group than in the euthyroid group, whereas acute insulin response to glucose was higher. Glucose effectiveness and disposition index were not different between groups. Basal serum GH and IGF-1 concentrations as well as abdominal fat content were high in hypothyroid dogs, but urine cortisol-to-creatinine concentration ratios were unchanged. Hypothyroidism appeared to negatively affect glucose homeostasis by inducing insulin resistance, but overall glucose tolerance was maintained by increased insulin secretion in hypothyroid dogs. Possible factors affecting insulin sensitivity are high serum GH and IGF-1 concentrations and an increase in abdominal fat. In dogs with diseases involving impaired insulin secretion such as diabetes mellitus, concurrent hypothyroidism can have important clinical implications.

  18. Ultra-sensitive speciation analysis of mercury by CE-ICP-MS together with field-amplified sample stacking injection and dispersive solid-phase extraction.

    PubMed

    Chen, YiQuan; Cheng, Xian; Mo, Fan; Huang, LiMei; Wu, Zujian; Wu, Yongning; Xu, LiangJun; Fu, FengFu

    2016-04-01

    A simple dispersive solid-phase extraction (DSPE) used to extract and preconcentrate ultra-trace MeHg, EtHg and Hg(2+) from water sample, and a sensitive method for the simultaneous analysis of MeHg, EtHg and Hg(2+) by using capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) with field-amplified sample stacking injection (FASI) were first reported in this study. The DSPE used thiol cotton particles as adsorbent, and is simple and effective. It can be used to extract and preconcentrate ultra-trace mercury compounds in water samples within 30 min with a satisfied recovery and no mercury species alteration during the process. The FASI enhanced the sensitivity of CE-ICP-MS with 25-fold, 29-fold and 27-fold for MeHg, EtHg and Hg(2+) , respectively. Using FASI-CE-ICP-MS together with DSPE, we have successfully determined ultra-trace MeHg, EtHg and Hg(2+) in tap water with a limits of quantification (LOQs) of 0.26-0.45 pg/mL, an RSD (n = 3) < 6% and a recovery of 92-108%. Ultra-high sensitivity, as well as much less sample and reagent consumption and low operating cost, make our method a valuable technique to the speciation analysis of ultra-trace mercury. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Sensitization to common allergens among patients with allergies in major Iranian cities: a systematic review and meta-analysis.

    PubMed

    Moghtaderi, Mozhgan; Hosseini Teshnizi, Saeed; Farjadian, Shirin

    2017-01-01

    Various allergens are implicated in the pathogenesis of allergic diseases in different regions. This study attempted to identify the most common allergens among patients with allergies based on the results of skin prick tests in different parts of Iran. Relevant studies conducted from 2000 to 2016 were identified from the MEDLINE database. Six common groups of allergen types, including animal, cockroach, food, fungus, house dust mite, and pollen were considered. Subgroup analysis was performed to determine the prevalence of each type of allergen. The Egger test was used to assess publication bias. We included 44 studies in this meta-analysis. The overall prevalence of positive skin test results for at least one allergen was estimated to be 59% in patients with allergies in various parts of Iran. The number of patients was 11,646 (56% male and 44% female), with a mean age of 17.46±11.12 years. The most common allergen sources were pollen (47.0%), mites (35.2%), and food (15.3%). The prevalence of sensitization to food and cockroach allergens among children was greater than among adults. Pollen is the most common allergen sensitization in cities of Iran with a warm and dry climate; however, sensitization to house dust mites is predominant in northern and southern coastal areas of Iran.

  20. Sensitization to common allergens among patients with allergies in major Iranian cities: a systematic review and meta-analysis

    PubMed Central

    Farjadian, Shirin

    2017-01-01

    Various allergens are implicated in the pathogenesis of allergic diseases in different regions. This study attempted to identify the most common allergens among patients with allergies based on the results of skin prick tests in different parts of Iran. Relevant studies conducted from 2000 to 2016 were identified from the MEDLINE database. Six common groups of allergen types, including animal, cockroach, food, fungus, house dust mite, and pollen were considered. Subgroup analysis was performed to determine the prevalence of each type of allergen. The Egger test was used to assess publication bias. We included 44 studies in this meta-analysis. The overall prevalence of positive skin test results for at least one allergen was estimated to be 59% in patients with allergies in various parts of Iran. The number of patients was 11,646 (56% male and 44% female), with a mean age of 17.46±11.12 years. The most common allergen sources were pollen (47.0%), mites (35.2%), and food (15.3%). The prevalence of sensitization to food and cockroach allergens among children was greater than among adults. Pollen is the most common allergen sensitization in cities of Iran with a warm and dry climate; however, sensitization to house dust mites is predominant in northern and southern coastal areas of Iran. PMID:28171712

  1. Sensitivity of land surface modeling to parameters: An uncertainty quantification method applied to the Community Land Model

    NASA Astrophysics Data System (ADS)

    Ricciuto, D. M.; Mei, R.; Mao, J.; Hoffman, F. M.; Kumar, J.

    2015-12-01

    Uncertainties in land parameters could have important impacts on simulated water and energy fluxes and land surface states, which will consequently affect atmospheric and biogeochemical processes. Therefore, quantification of such parameter uncertainties using a land surface model is the first step towards better understanding of predictive uncertainty in Earth system models. In this study, we applied a random-sampling, high-dimensional model representation (RS-HDMR) method to analyze the sensitivity of simulated photosynthesis, surface energy fluxes and surface hydrological components to selected land parameters in version 4.5 of the Community Land Model (CLM4.5). Because of the large computational expense of conducting ensembles of global gridded model simulations, we used the results of a previous cluster analysis to select one thousand representative land grid cells for simulation. Plant functional type (PFT)-specific uniform prior ranges for land parameters were determined using expert opinion and literature survey, and samples were generated with a quasi-Monte Carlo approach-Sobol sequence. Preliminary analysis of 1024 simulations suggested that four PFT-dependent parameters (including slope of the conductance-photosynthesis relationship, specific leaf area at canopy top, leaf C:N ratio and fraction of leaf N in RuBisco) are the dominant sensitive parameters for photosynthesis, surface energy and water fluxes across most PFTs, but with varying importance rankings. On the other hand, for surface ans sub-surface runoff, PFT-independent parameters, such as the depth-dependent decay factors for runoff, play more important roles than the previous four PFT-dependent parameters. Further analysis by conditioning the results on different seasons and years are being conducted to provide guidance on how climate variability and change might affect such sensitivity. This is the first step toward coupled simulations including biogeochemical processes, atmospheric processes or both to determine the full range of sensitivity of Earth system modeling to land-surface parameters. This can facilitate sampling strategies in measurement campaigns targeted at reduction of climate modeling uncertainties and can also provide guidance on land parameter calibration for simulation optimization.

  2. Glassy carbon electrode modified with carbon black for sensitive estradiol determination by means of voltammetry and flow injection analysis with amperometric detection.

    PubMed

    Smajdor, Joanna; Piech, Robert; Ławrywianiec, Martyna; Paczosa-Bator, Beata

    2018-03-01

    A voltammetric method for fast and sensitive estradiol determination using carbon black modified glassy carbon electrode (CBGC) is proposed. The use of carbon black as a modifying layer led to obtain low detection limit (9.2·10 -8  mol L -1 for a preconcentration time of 60 s) and stability of registered signals (measured as RSD is 1.3%, n = 7, estradiol concentration 0.5·10 -6  mol L -1 ). Cyclic voltammetry study revealed that in phosphate media estradiol suffers irreversible one-proton and one-electron oxidation process. Under the optimum conditions, estradiol calibration curve was linear in the concentration range from 0.15·10 -6 to 3.5·10 -6  mol L -1 . The proposed method enable to determine estradiol content in different pharmaceutical formulation with good recovery. Amperometric measurements of estradiol were performed as well to indicate the possibility of its fast and accurate determination under the flow conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The performance of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury: a meta-analysis.

    PubMed

    Wang, Z X; Chen, S L; Wang, Q Q; Liu, B; Zhu, J; Shen, J

    2015-06-01

    The aim of this study was to evaluate the accuracy of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury through a meta-analysis. A comprehensive literature search was conducted before 1 April 2014. All studies comparing magnetic resonance imaging results with arthroscopy or open surgery findings were reviewed, and 25 studies that satisfied the eligibility criteria were included. Data were pooled to yield pooled sensitivity and specificity, which were respectively 0.83 and 0.82. In detection of central and peripheral tears, magnetic resonance imaging had respectively a pooled sensitivity of 0.90 and 0.88 and a pooled specificity of 0.97 and 0.97. Six high-quality studies using Ringler's recommended magnetic resonance imaging parameters were selected for analysis to determine whether optimal imaging protocols yielded better results. The pooled sensitivity and specificity of these six studies were 0.92 and 0.82, respectively. The overall accuracy of magnetic resonance imaging was acceptable. For peripheral tears, the pooled data showed a relatively high accuracy. Magnetic resonance imaging with appropriate parameters are an ideal method for diagnosing different types of triangular fibrocartilage complex tears. © The Author(s) 2015.

  4. Sensitivity Analysis for Probabilistic Neural Network Structure Reduction.

    PubMed

    Kowalski, Piotr A; Kusy, Maciej

    2018-05-01

    In this paper, we propose the use of local sensitivity analysis (LSA) for the structure simplification of the probabilistic neural network (PNN). Three algorithms are introduced. The first algorithm applies LSA to the PNN input layer reduction by selecting significant features of input patterns. The second algorithm utilizes LSA to remove redundant pattern neurons of the network. The third algorithm combines the proposed two and constitutes the solution of how they can work together. PNN with a product kernel estimator is used, where each multiplicand computes a one-dimensional Cauchy function. Therefore, the smoothing parameter is separately calculated for each dimension by means of the plug-in method. The classification qualities of the reduced and full structure PNN are compared. Furthermore, we evaluate the performance of PNN, for which global sensitivity analysis (GSA) and the common reduction methods are applied, both in the input layer and the pattern layer. The models are tested on the classification problems of eight repository data sets. A 10-fold cross validation procedure is used to determine the prediction ability of the networks. Based on the obtained results, it is shown that the LSA can be used as an alternative PNN reduction approach.

  5. Fast calculation of the sensitivity matrix in magnetic induction tomography by tetrahedral edge finite elements and the reciprocity theorem.

    PubMed

    Hollaus, K; Magele, C; Merwa, R; Scharfetter, H

    2004-02-01

    Magnetic induction tomography of biological tissue is used to reconstruct the changes in the complex conductivity distribution by measuring the perturbation of an alternating primary magnetic field. To facilitate the sensitivity analysis and the solution of the inverse problem a fast calculation of the sensitivity matrix, i.e. the Jacobian matrix, which maps the changes of the conductivity distribution onto the changes of the voltage induced in a receiver coil, is needed. The use of finite differences to determine the entries of the sensitivity matrix does not represent a feasible solution because of the high computational costs of the basic eddy current problem. Therefore, the reciprocity theorem was exploited. The basic eddy current problem was simulated by the finite element method using symmetric tetrahedral edge elements of second order. To test the method various simulations were carried out and discussed.

  6. Parameter Estimation and Sensitivity Analysis of an Urban Surface Energy Balance Parameterization at a Tropical Suburban Site

    NASA Astrophysics Data System (ADS)

    Harshan, S.; Roth, M.; Velasco, E.

    2014-12-01

    Forecasting of the urban weather and climate is of great importance as our cities become more populated and considering the combined effects of global warming and local land use changes which make urban inhabitants more vulnerable to e.g. heat waves and flash floods. In meso/global scale models, urban parameterization schemes are used to represent the urban effects. However, these schemes require a large set of input parameters related to urban morphological and thermal properties. Obtaining all these parameters through direct measurements are usually not feasible. A number of studies have reported on parameter estimation and sensitivity analysis to adjust and determine the most influential parameters for land surface schemes in non-urban areas. Similar work for urban areas is scarce, in particular studies on urban parameterization schemes in tropical cities have so far not been reported. In order to address above issues, the town energy balance (TEB) urban parameterization scheme (part of the SURFEX land surface modeling system) was subjected to a sensitivity and optimization/parameter estimation experiment at a suburban site in, tropical Singapore. The sensitivity analysis was carried out as a screening test to identify the most sensitive or influential parameters. Thereafter, an optimization/parameter estimation experiment was performed to calibrate the input parameter. The sensitivity experiment was based on the "improved Sobol's global variance decomposition method" . The analysis showed that parameters related to road, roof and soil moisture have significant influence on the performance of the model. The optimization/parameter estimation experiment was performed using the AMALGM (a multi-algorithm genetically adaptive multi-objective method) evolutionary algorithm. The experiment showed a remarkable improvement compared to the simulations using the default parameter set. The calibrated parameters from this optimization experiment can be used for further model validation studies to identify inherent deficiencies in model physics.

  7. Label free quantitative proteomics analysis on the cisplatin resistance in ovarian cancer cells.

    PubMed

    Wang, F; Zhu, Y; Fang, S; Li, S; Liu, S

    2017-05-20

    Quantitative proteomics has been made great progress in recent years. Label free quantitative proteomics analysis based on the mass spectrometry is widely used. Using this technique, we determined the differentially expressed proteins in the cisplatin-sensitive ovarian cancer cells COC1 and cisplatin-resistant cells COC1/DDP before and after the application of cisplatin. Using the GO analysis, we classified those proteins into different subgroups bases on their cellular component, biological process, and molecular function. We also used KEGG pathway analysis to determine the key signal pathways that those proteins were involved in. There are 710 differential proteins between COC1 and COC1/DDP cells, 783 between COC1 and COC1/DDP cells treated with cisplatin, 917 between the COC1/DDP cells and COC1/DDP cells treated with LaCl3, 775 between COC1/DDP cells treated with cisplatin and COC1/DDP cells treated with cisplatin and LaCl3. Among the same 411 differentially expressed proteins in cisplatin-sensitive COC1 cells and cisplain-resistant COC1/DDP cells before and after cisplatin treatment, 14% of them were localized on the cell membrane. According to the KEGG results, differentially expressed proteins were classified into 21 groups. The most abundant proteins were involved in spliceosome. This study lays a foundation for deciphering the mechanism for drug resistance in ovarian tumor.

  8. Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection.

    PubMed

    Kishikawa, Naoya; Kondo, Naoko; Amponsaa-Karikari, Abena; Kodamatani, Hitoshi; Ohyama, Kaname; Nakashima, Kenichiro; Yamazaki, Shigeo; Kuroda, Naotaka

    2014-02-01

    Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on-line photoreactor. This method is based on on-line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.

  9. [Determination of aluminum in sediments by atomic absorption spectrophotometer without FIA spectrophotometric analysis].

    PubMed

    Zhao, Zhen-yi; Han, Guang-xi; Song, Xi-ming; Luo, Zhi-xiong

    2008-06-01

    To search for a new method of determining, we developed a new flow injection analyzer, applied to the atomic absorption spectrophotometer, relying on it without flame in place of visible spectrophotometer, and studied the appropriate condition for the determination of aluminum in sediments, thus built up a kind of new analytical test technique. Three peak and two valley absorption values (A1, A2, A3, A4 and A5) can be continuously obtained simultaneously that all can be used for quantitative analysis, then we discussed its theory and experiment technique. Based on the additivity of absorbance (A = A1+A2+A3+A4+ A5), the sensitivity of FIA is enhanced, and its precision and linear relation are also good, raising the efficiency of AAS. The simple method has been applied to determining Al in sediments, and the results are satisfactory.

  10. Study of advanced techniques for determining the long term performance of components

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The application of existing and new technology to the problem of determining the long-term performance capability of liquid rocket propulsion feed systems is discussed. The long term performance of metal to metal valve seats in a liquid propellant fuel system is stressed. The approaches taken in conducting the analysis are: (1) advancing the technology of characterizing components through the development of new or more sensitive techniques and (2) improving the understanding of the physical of degradation.

  11. Molecule-Specific Imaging Analysis of Carcinogens in Breast Cancer Cells Using Time-of-Flight Secondary Ion Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quong, J N; Knize, M G; Kulp, K S

    2003-08-19

    Imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) is used to study the localization of heterocyclic amines in MCF7 line of human breast cancer cells. The detection sensitivities of a model rodent mutagen, 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were determined. Following an established criteria for the determination of status of freeze-fracture cells, the distribution of PhIP in the MCF7 cells are reported.

  12. Infrared measurements of a scramjet exhaust. [to determine combustion efficiency

    NASA Technical Reports Server (NTRS)

    Reed, R. A.; Slack, M. W.

    1980-01-01

    Diagnostic 2 - 5 mm infrared spectra of a hydrogen burning scramjet exhaust were measured with an interferometer spectrometer. Exhaust gas temperatures and water vapor partial pressures were determined from the observed intensity and spectral profile of the H2O 2.7 mm infrared emission band. Overall engine combustion efficiencies were derived by combining these measurements with the known engine operating conditions. Efficiencies fall (70 - 50 percent) as fuel equivalence ratios rise (0.4 - 1.0). Data analysis techniques and sensitivity studies are also presented.

  13. Determination of 1-aminocyclopropane-1-carboxylic acid in apple extracts by capillary electrophoresis with laser-induced fluorescence detection.

    PubMed

    Liu, Xin; Li, Dian-Fan; Wang, Yun; Lu, Ying-Tang

    2004-12-17

    A rapid and sensitive method for the determination of 1-aminocyclopropane-1-carboxylic acid (ACC) in apple tissues has been described. This method is based on the derivatization of ACC with 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ), and separation and quantification of the resulting FQ-ACC derivative by capillary electrophoresis coupled to laser-induced fluorescence detection (CE-LIF). Our results indicated that ACC derivatized with FQ could be well separated from other interfering amino acids using 20 mM borate buffer (pH 9.35) containing 40 mM sodium dodecyl sulfate and 10 mM Brij 35. The linearity of ACC was determined in the range from 0.05 to 5 microM with a correlation of 0.9967. The concentration detection limit for ACC was 10 nM (signal-to-noise = 3). The sensitivity and selectivity of this described method allows the analysis of ACC in crude apple extracts without extra purification and enrichment procedure.

  14. Surface determination through atomically resolved secondary-electron imaging

    PubMed Central

    Ciston, J.; Brown, H. G.; D'Alfonso, A. J.; Koirala, P.; Ophus, C.; Lin, Y.; Suzuki, Y.; Inada, H.; Zhu, Y.; Allen, L. J.; Marks, L. D.

    2015-01-01

    Unique determination of the atomic structure of technologically relevant surfaces is often limited by both a need for homogeneous crystals and ambiguity of registration between the surface and bulk. Atomically resolved secondary-electron imaging is extremely sensitive to this registration and is compatible with faceted nanomaterials, but has not been previously utilized for surface structure determination. Here we report a detailed experimental atomic-resolution secondary-electron microscopy analysis of the c(6 × 2) reconstruction on strontium titanate (001) coupled with careful simulation of secondary-electron images, density functional theory calculations and surface monolayer-sensitive aberration-corrected plan-view high-resolution transmission electron microscopy. Our work reveals several unexpected findings, including an amended registry of the surface on the bulk and strontium atoms with unusual seven-fold coordination within a typically high surface coverage of square pyramidal TiO5 units. Dielectric screening is found to play a critical role in attenuating secondary-electron generation processes from valence orbitals. PMID:26082275

  15. Surface determination through atomically resolved secondary-electron imaging

    DOE PAGES

    Ciston, J.; Brown, H. G.; D’Alfonso, A. J.; ...

    2015-06-17

    We report that unique determination of the atomic structure of technologically relevant surfaces is often limited by both a need for homogeneous crystals and ambiguity of registration between the surface and bulk. Atomically resolved secondary-electron imaging is extremely sensitive to this registration and is compatible with faceted nanomaterials, but has not been previously utilized for surface structure determination. Here we show a detailed experimental atomic-resolution secondary-electron microscopy analysis of the c(6 x 2) reconstruction on strontium titanate (001) coupled with careful simulation of secondary-electron images, density functional theory calculations and surface monolayer-sensitive aberration-corrected plan-view high-resolution transmission electron microscopy. Our workmore » reveals several unexpected findings, including an amended registry of the surface on the bulk and strontium atoms with unusual seven-fold coordination within a typically high surface coverage of square pyramidal TiO 5 units. Lastly, dielectric screening is found to play a critical role in attenuating secondary-electron generation processes from valence orbitals.« less

  16. Quantitative polarized light microscopy using spectral multiplexing interferometry.

    PubMed

    Li, Chengshuai; Zhu, Yizheng

    2015-06-01

    We propose an interferometric spectral multiplexing method for measuring birefringent specimens with simple configuration and high sensitivity. The retardation and orientation of sample birefringence are simultaneously encoded onto two spectral carrier waves, generated interferometrically by a birefringent crystal through polarization mixing. A single interference spectrum hence contains sufficient information for birefringence determination, eliminating the need for mechanical rotation or electrical modulation. The technique is analyzed theoretically and validated experimentally on cellulose film. System simplicity permits the possibility of mitigating system birefringence background. Further analysis demonstrates the technique's exquisite sensitivity as high as ∼20  pm for retardation measurement.

  17. Mathematical modeling of a thermovoltaic cell

    NASA Technical Reports Server (NTRS)

    White, Ralph E.; Kawanami, Makoto

    1992-01-01

    A new type of battery named 'Vaporvolt' cell is in the early stage of its development. A mathematical model of a CuO/Cu 'Vaporvolt' cell is presented that can be used to predict the potential and the transport behavior of the cell during discharge. A sensitivity analysis of the various transport and electrokinetic parameters indicates which parameters have the most influence on the predicted energy and power density of the 'Vaporvolt' cell. This information can be used to decide which parameters should be optimized or determined more accurately through further modeling or experimental studies. The optimal thicknesses of electrodes and separator, the concentration of the electrolyte, and the current density are determined by maximizing the power density. These parameter sensitivities and optimal design parameter values will help in the development of a better CuO/Cu 'Vaporvolt' cell.

  18. Sensitive determination of RDX, nitroso-RDX metabolites, and other munitions in ground water by solid-phase extraction and isotope dilution liquid chromatography-atmospheric pressure electro-spray [correction of chemical] ionization mass spectrometry.

    PubMed

    Cassada, D A; Monson, S J; Snow, D D; Spalding, R F

    1999-06-04

    Recent improvements in the LC-MS interface have increased the sensitivity and selectivity of this instrument in the analysis of polar and thermally-labile aqueous constituents. Determination of RDX, nitroso-RDX metabolites, and other munitions was enhanced using LC-MS with solid-phase extraction, 15N3-RDX internal standard, and electrospray ionization (ESI) in negative ion mode. ESI produced a five-fold increase in detector response over atmospheric pressure chemical ionization (APCI) for the nitramine compounds, while the more energetic APCI produced more than twenty times the ESI response for nitroaromatics. Method detection limits in ESI for nitramines varied from 0.03 microgram l-1 for MNX to 0.05 microgram l-1 for RDX.

  19. Multielement extraction system for determining 19 trace elements in gold exploration samples

    USGS Publications Warehouse

    Clark, J. Robert; Viets, John G.; ,

    1990-01-01

    A multielement extraction system is being used successfully to provide essentially interference-free geochemical analyses to aid in gold exploration. The Methyl isobutyl ketone-Amine synerGistic Iodide Complex (MAGIC) extraction system separates Ag, As, Au, Bi, Cd, Cu, Ga, Hg, In, Mo, Pb, Pd, Pt, Sb, Se, Sn, Te, Tl, and Zn from interfering geological matrices. Quantitative extraction of these elements is accomplished over a broad range of acid normality making it possible to economically determine all 19 elements from a single digestion or leach solution. The resulting organic extracts are amenable to analysis by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and flame atomic absorption spectroscopy (FAAS). For many years the principal shortcoming of ICP-AES was the complex spectral and stray-light interferences that were caused by the extreme variability of components such as Fe, Na, and Ca in common geological matrices. The MAGIC extraction allows determination of the extracted elements with enhanced sensitivity, from a virtually uniform matrix, by ICP-AES and FAAS. Because of its simultaneous multichannel capabilities, ICP-AES is the ideal instrumental technique for determining these 19 extracted elements. Ultratrace (sub-part-per-billion) determinations of Au and many of the other extracted elements can be made by graphite furnace atomic absorption spectroscopy (GFAAS), following back stripping of the extracts. The combination of the extraction followed by stripping of the organic phase eliminates 99.999% of potential interferences for Au. Gold determination by GFAAS from these extracts under the specified conditions yields a fourfold improvement in sensitivity over conventional GFAAS methods. This sensitivity enhancement and the interference-free matrix allow highly reliable determinations well into the parts-per-trillion range.

  20. Electron spin resonance as a high sensitivity technique for environmental magnetism: determination of contamination in carbonate sediments

    NASA Astrophysics Data System (ADS)

    Crook, Nigel P.; Hoon, Stephen R.; Taylor, Kevin G.; Perry, Chris T.

    2002-05-01

    This study investigates the application of high sensitivity electron spin resonance (ESR) to environmental magnetism in conjunction with the more conventional techniques of magnetic susceptibility, vibrating sample magnetometry (VSM) and chemical compositional analysis. Using these techniques we have studied carbonate sediment samples from Discovery Bay, Jamaica, which has been impacted to varying degrees by a bauxite loading facility. The carbonate sediment samples contain magnetic minerals ranging from moderate to low concentrations. The ESR spectra for all sites essentially contain three components. First, a six-line spectra centred around g = 2 resulting from Mn2+ ions within a carbonate matrix; second a g = 4.3 signal from isolated Fe3+ ions incorporated as impurities within minerals such as gibbsite, kaolinite or quartz; third a ferrimagnetic resonance with a maxima at 230 mT resulting from the ferrimagnetic minerals present within the bauxite contamination. Depending upon the location of the sites within the embayment these signals vary in their relative amplitude in a systematic manner related to the degree of bauxite input. Analysis of the ESR spectral components reveals linear relationships between the amplitude of the Mn2+ and ferrimagnetic signals and total Mn and Fe concentrations. To assist in determining the origin of the ESR signals coral and bauxite reference samples were employed. Coral representative of the matrix of the sediment was taken remote from the bauxite loading facility whilst pure bauxite was collected from nearby mining facilities. We find ESR to be a very sensitive technique particularly appropriate to magnetic analysis of ferri- and para-magnetic components within environmental samples otherwise dominated by diamagnetic (carbonate) minerals. When employing typical sample masses of 200 mg the practical detection limit of ESR to ferri- and para-magnetic minerals within a diamagnetic carbonate matrix is of the order of 1 ppm and 1 ppb respectively, approximately 102 and 105 times the sensitivity achievable employing the VSM in our laboratory.

  1. New features and improved uncertainty analysis in the NEA nuclear data sensitivity tool (NDaST)

    NASA Astrophysics Data System (ADS)

    Dyrda, J.; Soppera, N.; Hill, I.; Bossant, M.; Gulliford, J.

    2017-09-01

    Following the release and initial testing period of the NEA's Nuclear Data Sensitivity Tool [1], new features have been designed and implemented in order to expand its uncertainty analysis capabilities. The aim is to provide a free online tool for integral benchmark testing, that is both efficient and comprehensive, meeting the needs of the nuclear data and benchmark testing communities. New features include access to P1 sensitivities for neutron scattering angular distribution [2] and constrained Chi sensitivities for the prompt fission neutron energy sampling. Both of these are compatible with covariance data accessed via the JANIS nuclear data software, enabling propagation of the resultant uncertainties in keff to a large series of integral experiment benchmarks. These capabilities are available using a number of different covariance libraries e.g., ENDF/B, JEFF, JENDL and TENDL, allowing comparison of the broad range of results it is possible to obtain. The IRPhE database of reactor physics measurements is now also accessible within the tool in addition to the criticality benchmarks from ICSBEP. Other improvements include the ability to determine and visualise the energy dependence of a given calculated result in order to better identify specific regions of importance or high uncertainty contribution. Sorting and statistical analysis of the selected benchmark suite is now also provided. Examples of the plots generated by the software are included to illustrate such capabilities. Finally, a number of analytical expressions, for example Maxwellian and Watt fission spectra will be included. This will allow the analyst to determine the impact of varying such distributions within the data evaluation, either through adjustment of parameters within the expressions, or by comparison to a more general probability distribution fitted to measured data. The impact of such changes is verified through calculations which are compared to a `direct' measurement found by adjustment of the original ENDF format file.

  2. Experimental demonstration and theoretical explanation of the efficiency of the nano-structured silicon as the transducer for optical immune biosensors

    NASA Astrophysics Data System (ADS)

    Starodub, Nickolaj F.; Slyshyk, Nelya F.; Shavanova, Kateryna E.; Karpyuk, Andrij; Mel'nichenko, Mykola M.; Zherdev, Anatolij V.; Dzantiev, Boris B.

    2014-10-01

    It is presented the experimental results about the investigations of the efficiency of the structured nano-pourous silicon (sNPS) application as transducer in the immune biosensors designed for the control of retroviral bovine leucosis (RBL) and the determination of the level such mycotoxins as T2 and patulin among environmental objects. Today, there is an arsenal of the traditional immunological methods that allow for the biochemical diagnostics of the above diseases and control of toxins but they are deeply routine and can not provide the requirements of practice for express analysis, its low cost and simplicity. Early to provide practical demands we developed immune biosensors based on SPR, TIRE and thermistors. To find more simple variant of the assay we studied the efficiency sNPS as trasducer in immune biosensor. The registration of the specific signals was made by measuremets of level of chemiluminescence (ChL) or photocurrent. The sensitivity of biosensor for both variants of the specific signal registration at the determination of T2 and patulin was about 10-20 ng/ml. Sensitivity analysis of RBL by this immune biosensors exceeds traditionally used approaches including the ELISA-method too. The optimal serum dilution of blood at the screening leukemia should be no less than 1:100, or even 1:500. The immune biosensor may be applied too for express screening leucosis through analysis of milk. In this case the optimal serum dilution of milk should be about 1:20. The total time of analysis including all steps (immobilization of specific Ab or antigens on the transducer surface and measurements) was about 40 min and it may be a sharp decline if the above mentione sensitive elements will be immobilized preliminary measurements. It is concluded that the proposed type of transducer for immune biosensor is effective for analysis of mycotoxins in screening regime.

  3. Observability Analysis of a MEMS INS/GPS Integration System with Gyroscope G-Sensitivity Errors

    PubMed Central

    Fan, Chen; Hu, Xiaoping; He, Xiaofeng; Tang, Kanghua; Luo, Bing

    2014-01-01

    Gyroscopes based on micro-electromechanical system (MEMS) technology suffer in high-dynamic applications due to obvious g-sensitivity errors. These errors can induce large biases in the gyroscope, which can directly affect the accuracy of attitude estimation in the integration of the inertial navigation system (INS) and the Global Positioning System (GPS). The observability determines the existence of solutions for compensating them. In this paper, we investigate the observability of the INS/GPS system with consideration of the g-sensitivity errors. In terms of two types of g-sensitivity coefficients matrix, we add them as estimated states to the Kalman filter and analyze the observability of three or nine elements of the coefficient matrix respectively. A global observable condition of the system is presented and validated. Experimental results indicate that all the estimated states, which include position, velocity, attitude, gyro and accelerometer bias, and g-sensitivity coefficients, could be made observable by maneuvering based on the conditions. Compared with the integration system without compensation for the g-sensitivity errors, the attitude accuracy is raised obviously. PMID:25171122

  4. Observability analysis of a MEMS INS/GPS integration system with gyroscope G-sensitivity errors.

    PubMed

    Fan, Chen; Hu, Xiaoping; He, Xiaofeng; Tang, Kanghua; Luo, Bing

    2014-08-28

    Gyroscopes based on micro-electromechanical system (MEMS) technology suffer in high-dynamic applications due to obvious g-sensitivity errors. These errors can induce large biases in the gyroscope, which can directly affect the accuracy of attitude estimation in the integration of the inertial navigation system (INS) and the Global Positioning System (GPS). The observability determines the existence of solutions for compensating them. In this paper, we investigate the observability of the INS/GPS system with consideration of the g-sensitivity errors. In terms of two types of g-sensitivity coefficients matrix, we add them as estimated states to the Kalman filter and analyze the observability of three or nine elements of the coefficient matrix respectively. A global observable condition of the system is presented and validated. Experimental results indicate that all the estimated states, which include position, velocity, attitude, gyro and accelerometer bias, and g-sensitivity coefficients, could be made observable by maneuvering based on the conditions. Compared with the integration system without compensation for the g-sensitivity errors, the attitude accuracy is raised obviously.

  5. Correlation between experimental human and murine skin sensitization induction thresholds.

    PubMed

    Api, Anne Marie; Basketter, David; Lalko, Jon

    2015-01-01

    Quantitative risk assessment for skin sensitization is directed towards the determination of levels of exposure to known sensitizing substances that will avoid the induction of contact allergy in humans. A key component of this work is the predictive identification of relative skin sensitizing potency, achieved normally by the measurement of the threshold (the "EC3" value) in the local lymph node assay (LLNA). In an extended series of studies, the accuracy of this murine induction threshold as the predictor of the absence of a sensitizing effect has been verified by conduct of a human repeated insult patch test (HRIPT). Murine and human thresholds for a diverse set of 57 fragrance chemicals spanning approximately four orders of magnitude variation in potency have been compared. The results confirm that there is a useful correlation, with the LLNA EC3 value helping particularly to identify stronger sensitizers. Good correlation (with half an order of magnitude) was seen with three-quarters of the dataset. The analysis also helps to identify potential outlier types of (fragrance) chemistry, exemplified by hexyl and benzyl salicylates (an over-prediction) and trans-2-hexenal (an under-prediction).

  6. Validation of different measures of insulin sensitivity of glucose metabolism in dairy cows using the hyperinsulinemic euglycemic clamp test as the gold standard.

    PubMed

    De Koster, J; Hostens, M; Hermans, K; Van den Broeck, W; Opsomer, G

    2016-10-01

    The aim of the present research was to compare different measures of insulin sensitivity in dairy cows at the end of the dry period. To do so, 10 clinically healthy dairy cows with a varying body condition score were selected. By performing hyperinsulinemic euglycemic clamp (HEC) tests, we previously demonstrated a negative association between the insulin sensitivity and insulin responsiveness of glucose metabolism and the body condition score of these animals. In the same animals, other measures of insulin sensitivity were determined and the correlation with the HEC test, which is considered as the gold standard, was calculated. Measures derived from the intravenous glucose tolerance test (IVGTT) are based on the disappearance of glucose after an intravenous glucose bolus. Glucose concentrations during the IVGTT were used to calculate the area under the curve of glucose and the clearance rate of glucose. In addition, glucose and insulin data from the IVGTT were fitted in the minimal model to derive the insulin sensitivity parameter, Si. Based on blood samples taken before the start of the IVGTT, basal concentrations of glucose, insulin, NEFA, and β-hydroxybutyrate were determined and used to calculate surrogate indices for insulin sensitivity, such as the homeostasis model of insulin resistance, the quantitative insulin sensitivity check index, the revised quantitative insulin sensitivity check index and the revised quantitative insulin sensitivity check index including β-hydroxybutyrate. Correlation analysis revealed no association between the results obtained by the HEC test and any of the surrogate indices for insulin sensitivity. For the measures derived from the IVGTT, the area under the curve for the first 60 min of the test and the Si derived from the minimal model demonstrated good correlation with the gold standard. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. 13C labeling analysis of sugars by high resolution-mass spectrometry for metabolic flux analysis.

    PubMed

    Acket, Sébastien; Degournay, Anthony; Merlier, Franck; Thomasset, Brigitte

    2017-06-15

    Metabolic flux analysis is particularly complex in plant cells because of highly compartmented metabolism. Analysis of free sugars is interesting because it provides data to define fluxes around hexose, pentose, and triose phosphate pools in different compartment. In this work, we present a method to analyze the isotopomer distribution of free sugars labeled with carbon 13 using a liquid chromatography-high resolution mass spectrometry, without derivatized procedure, adapted for Metabolic flux analysis. Our results showed a good sensitivity, reproducibility and better accuracy to determine isotopic enrichments of free sugars compared to our previous methods [5, 6]. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Framework to evaluate the worth of hydraulic conductivity data for optimal groundwater resources management in ecologically sensitive areas

    NASA Astrophysics Data System (ADS)

    Feyen, Luc; Gorelick, Steven M.

    2005-03-01

    We propose a framework that combines simulation optimization with Bayesian decision analysis to evaluate the worth of hydraulic conductivity data for optimal groundwater resources management in ecologically sensitive areas. A stochastic simulation optimization management model is employed to plan regionally distributed groundwater pumping while preserving the hydroecological balance in wetland areas. Because predictions made by an aquifer model are uncertain, groundwater supply systems operate below maximum yield. Collecting data from the groundwater system can potentially reduce predictive uncertainty and increase safe water production. The price paid for improvement in water management is the cost of collecting the additional data. Efficient data collection using Bayesian decision analysis proceeds in three stages: (1) The prior analysis determines the optimal pumping scheme and profit from water sales on the basis of known information. (2) The preposterior analysis estimates the optimal measurement locations and evaluates whether each sequential measurement will be cost-effective before it is taken. (3) The posterior analysis then revises the prior optimal pumping scheme and consequent profit, given the new information. Stochastic simulation optimization employing a multiple-realization approach is used to determine the optimal pumping scheme in each of the three stages. The cost of new data must not exceed the expected increase in benefit obtained in optimal groundwater exploitation. An example based on groundwater management practices in Florida aimed at wetland protection showed that the cost of data collection more than paid for itself by enabling a safe and reliable increase in production.

  9. Non-invasive fetal sex determination by maternal plasma sequencing and application in X-linked disorder counseling.

    PubMed

    Pan, Xiaoyu; Zhang, Chunlei; Li, Xuchao; Chen, Shengpei; Ge, Huijuan; Zhang, Yanyan; Chen, Fang; Jiang, Hui; Jiang, Fuman; Zhang, Hongyun; Wang, Wei; Zhang, Xiuqing

    2014-12-01

    To develop a fetal sex determination method based on maternal plasma sequencing (MPS), assess its performance and potential use in X-linked disorder counseling. 900 cases of MPS data from a previous study were reviewed, in which 100 and 800 cases were used as training and validation set, respectively. The percentage of uniquely mapped sequencing reads on Y chromosome was calculated and used to classify male and female cases. Eight pregnant women who are carriers of Duchenne muscular dystrophy (DMD) mutations were recruited, whose plasma were subjected to multiplex sequencing and fetal sex determination analysis. In the training set, a sensitivity of 96% and false positive rate of 0% for male cases detection were reached in our method. The blinded validation results showed 421 in 423 male cases and 374 in 377 female cases were successfully identified, revealing sensitivity and specificity of 99.53% and 99.20% for fetal sex determination, at as early as 12 gestational weeks. Fetal sex for all eight DMD genetic counseling cases were correctly identified, which were confirmed by amniocentesis. Based on MPS, high accuracy of non-invasive fetal sex determination can be achieved. This method can potentially be used for prenatal genetic counseling.

  10. Flame photometric determination of strontium in water

    USGS Publications Warehouse

    Skougstad, Marvin W.

    1957-01-01

    Preliminary search of reported methods of Sr analysis revealed several investigations which have been made for the determination of Sr with the flame photometer, both at relatively low concentrations (0 to 50 ppm Sr) and at higher concentrations. Generally the procedures described involved measurement of Sr emission at either 460.7 mu or at 681 mu. There is disagreement among those reporting methods for Sr as to the preference of the one wavelength over the other. The 681 line (or band) seems to be preferred because of its greater reproducibility and relative freedom from interference. The 460.7 mu line, however, lies in the region of greater sensitivity of the photomultiplier tube, and hence for this reason is preferred by some. This is an advantage, of course, when determining Sr at very low concentrations. This investigation is concerned with determining the optimum conditions for the determination of Sr at low concentration levels in water samples. Early experimental work indicated a greater sensitivity for the 460.7 mu (hereafter designated as 461 mu) Sr line. Therefore, most of the subsequent work was based on a study of the effects of various other materials and conditions on the emission of Sr at this wavelength.

  11. Solid phase extraction of amoxicillin using dibenzo-18-crown-6 modified magnetic-multiwalled carbon nanotubes prior to its spectrophotometric determination.

    PubMed

    Ahmadi, Mazaher; Madrakian, Tayyebeh; Afkhami, Abbas

    2016-01-01

    This work reports on a method for selective extraction and sensitive determination of amoxicillin drug (AMX). The method is based on solid phase extraction of AMX by a novel modified magnetic nanoadsorbent prior to spectrophotometric determination of AMX using a procedure based on formation a colored azo-derivative of the investigated drug. The nanoadsorbent has been synthesized by modification of magnetic-multiwalled carbon nanotube with dibenzo-18-crown-6 moieties. The synthesized nanoparticles were characterized using TEM, XRD and FT-IR measurements. At the next step, various factors that could potentially affect adsorption and desorption efficiencies of AMX, have been optimized. The results showed that under the optimized conditions, sensitive and selective determination of the investigated drug in concentration range of 5.0-1000.0 ng mL(-1) with the limit of detection of 3.0 ng mL(-1) was achievable. Furthermore, the real sample analysis (i.e. amoxicillin capsules and human urine samples) results indicated that a reliable promising candidate method has been developed for the determination of AMX in the investigated real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Urinary neutrophil gelatinase-associated lipocalin for diagnosis and estimating activity in lupus nephritis: a meta-analysis.

    PubMed

    Fang, Y G; Chen, N N; Cheng, Y B; Sun, S J; Li, H X; Sun, F; Xiang, Y

    2015-12-01

    Urinary neutrophil gelatinase-associated lipocalin (uNGAL) is relatively specific in lupus nephritis (LN) patients. However, its diagnostic value has not been evaluated. The aim of this review was to determine the value of uNGAL for diagnosis and estimating activity in LN. A comprehensive search was performed on PubMed, EMBASE, Web of Knowledge, Cochrane electronic databases through December 2014. Meta-analysis of sensitivity and specificity was performed with a random-effects model. Additionally, summary receiver operating characteristic (SROC) curves and area under the curve (AUC) values were calculated. Fourteen studies were selected for this review. With respect to diagnosing LN, the pooled sensitivity and specificity were 73.6% (95% confidence interval (CI), 61.9-83.3) and 78.1% (95% CI, 69.0-85.6), respectively. The SROC-AUC value was 0.8632. Regarding estimating LN activity, the pooled sensitivity and specificity were 66.2% (95% CI, 60.4-71.7) and 62.1% (95% CI, 57.9-66.3), respectively. The SROC-AUC value was 0.7583. In predicting renal flares, the pooled sensitivity and specificity were 77.5% (95% CI, 68.1-85.1) and 65.3% (95% CI, 60.0-70.3), respectively. The SROC-AUC value was 0.7756. In conclusion, this meta-analysis indicates that uNGAL has relatively fair sensitivity and specificity in diagnosing LN, estimating LN activity and predicting renal flares, suggesting that uNGAL is a potential biomarker in diagnosing LN and monitoring LN activity. © The Author(s) 2015.

  13. Rapid separation and sensitive determination of banned aromatic amines with plastic microchip electrophoresis.

    PubMed

    Li, Ruina; Wang, Lili; Gao, Xiaotong; Du, Gangfeng; Zhai, Honglin; Wang, Xiayan; Guo, Guangsheng; Pu, Qiaosheng

    2013-03-15

    Rapid analysis of trace amount of aromatic amines in environmental samples and daily necessities has attracted considerable attentions because some of them are strongly toxic and carcinogenic. In this study, fast and efficient electrophoretic separation and sensitive determination of 5 banned aromatic amines were explored for practical analysis using disposable plastic microchips combined with a low-cost laser-induced fluorescence detector. The effect of running buffer and its additive was systematically investigated. Under the selected condition, 5 fluorescein isothiocyanate labeled aromatic amines could be baseline separated within 90s by using a 10mmol/L borate buffer containing 2% (w/v) hydroxypropyl cellulose. Calibration curves of peak areas vs. concentrations were linear up to 40 or 120μmol/L for different analytes and limits of detection were in a range of 1-3nmol/L. Theoretical plate numbers of 6.8-8.5×10(5)/m were readily achieved. The method exhibited good repeatability, relative standard deviations (n=5) of peak areas and migration times were no more than 4.6% and 0.9%, respectively. The established method was successfully applied in the quantitative analysis of these banned aromatic amines in real samples of waste water and textile, recoveries of added standards were 85-110%. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Exploring the Relationship between Reward and Punishment Sensitivity and Gambling Disorder in a Clinical Sample: A Path Modeling Analysis.

    PubMed

    Jiménez-Murcia, Susana; Fernández-Aranda, Fernando; Mestre-Bach, Gemma; Granero, Roser; Tárrega, Salomé; Torrubia, Rafael; Aymamí, Neus; Gómez-Peña, Mónica; Soriano-Mas, Carles; Steward, Trevor; Moragas, Laura; Baño, Marta; Del Pino-Gutiérrez, Amparo; Menchón, José M

    2017-06-01

    Most individuals will gamble during their lifetime, yet only a select few will develop gambling disorder. Gray's Reinforcement Sensitivity Theory holds promise for providing insight into gambling disorder etiology and symptomatology as it ascertains that neurobiological differences in reward and punishment sensitivity play a crucial role in determining an individual's affect and motives. The aim of the study was to assess a mediational pathway, which included patients' sex, personality traits, reward and punishment sensitivity, and gambling-severity variables. The Sensitivity to Punishment and Sensitivity to Reward Questionnaire, the South Oaks Gambling Screen, the Symptom Checklist-Revised, and the Temperament and Character Inventory-Revised were administered to a sample of gambling disorder outpatients (N = 831), diagnosed according to DSM-5 criteria, attending a specialized outpatient unit. Sociodemographic variables were also recorded. A structural equation model found that both reward and punishment sensitivity were positively and directly associated with increased gambling severity, sociodemographic variables, and certain personality traits while also revealing a complex mediational role for these dimensions. To this end, our findings suggest that the Sensitivity to Punishment and Sensitivity to Reward Questionnaire could be a useful tool for gaining a better understanding of different gambling disorder phenotypes and developing tailored interventions.

  15. Molecular determinants of magnesium-dependent synaptic plasticity at electrical synapses formed by connexin36

    NASA Astrophysics Data System (ADS)

    Palacios-Prado, Nicolás; Chapuis, Sandrine; Panjkovich, Alejandro; Fregeac, Julien; Nagy, James I.; Bukauskas, Feliksas F.

    2014-08-01

    Neuronal gap junction (GJ) channels composed of connexin36 (Cx36) play an important role in neuronal synchronization and network dynamics. Here we show that Cx36-containing electrical synapses between inhibitory neurons of the thalamic reticular nucleus are bidirectionally modulated by changes in intracellular free magnesium concentration ([Mg2+]i). Chimeragenesis demonstrates that the first extracellular loop of Cx36 contains a Mg2+-sensitive domain, and site-directed mutagenesis shows that the pore-lining residue D47 is critical in determining high Mg2+-sensitivity. Single-channel analysis of Mg2+-sensitive chimeras and mutants reveals that [Mg2+]i controls the strength of electrical coupling mostly via gating mechanisms. In addition, asymmetric transjunctional [Mg2+]i induces strong instantaneous rectification, providing a novel mechanism for electrical rectification in homotypic Cx36 GJs. We suggest that Mg2+-dependent synaptic plasticity of Cx36-containing electrical synapses could underlie neuronal circuit reconfiguration via changes in brain energy metabolism that affects neuronal levels of intracellular ATP and [Mg2+]i.

  16. Development of high-throughput and high sensitivity capillary gel electrophoresis platform method for Western, Eastern, and Venezuelan equine encephalitis (WEVEE) virus like particles (VLPs) purity determination and characterization.

    PubMed

    Gollapudi, Deepika; Wycuff, Diane L; Schwartz, Richard M; Cooper, Jonathan W; Cheng, K C

    2017-10-01

    In this paper, we describe development of a high-throughput, highly sensitive method based on Lab Chip CGE-SDS platform for purity determination and characterization of virus-like particle (VLP) vaccines. A capillary gel electrophoresis approach requiring about 41 s per sample for analysis and demonstrating sensitivity to protein initial concentrations as low as 20 μg/mL, this method has been used previously to evaluate monoclonal antibodies, but this application for lot release assay of VLPs using this platform is unique. The method was qualified and shown to be accurate for the quantitation of VLP purity. Assay repeatability was confirmed to be less than 2% relative standard deviation of the mean (% RSD) with interday precision less than 2% RSD. The assay can evaluate purified VLPs in a concentration range of 20-249 μg/mL for VEE and 20-250 μg/mL for EEE and WEE VLPs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A Comparison of Various Stress Rupture Life Models for Orbiter Composite Pressure Vessels and Confidence Intervals

    NASA Technical Reports Server (NTRS)

    Grimes-Ledesma, Lorie; Murthy, Pappu L. N.; Phoenix, S. Leigh; Glaser, Ronald

    2007-01-01

    In conjunction with a recent NASA Engineering and Safety Center (NESC) investigation of flight worthiness of Kevlar Overwrapped Composite Pressure Vessels (COPVs) on board the Orbiter, two stress rupture life prediction models were proposed independently by Phoenix and by Glaser. In this paper, the use of these models to determine the system reliability of 24 COPVs currently in service on board the Orbiter is discussed. The models are briefly described, compared to each other, and model parameters and parameter uncertainties are also reviewed to understand confidence in reliability estimation as well as the sensitivities of these parameters in influencing overall predicted reliability levels. Differences and similarities in the various models will be compared via stress rupture reliability curves (stress ratio vs. lifetime plots). Also outlined will be the differences in the underlying model premises, and predictive outcomes. Sources of error and sensitivities in the models will be examined and discussed based on sensitivity analysis and confidence interval determination. Confidence interval results and their implications will be discussed for the models by Phoenix and Glaser.

  18. The Influence of PV Module Materials and Design on Solder Joint Thermal Fatigue Durability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosco, Nick; Silverman, Timothy J.; Kurtz, Sarah

    Finite element model (FEM) simulations have been performed to elucidate the effect of flat plate photovoltaic (PV) module materials and design on PbSn eutectic solder joint thermal fatigue durability. The statistical method of Latin Hypercube sampling was employed to investigate the sensitivity of simulated damage to each input variable. Variables of laminate material properties and their thicknesses were investigated. Using analysis of variance, we determined that the rate of solder fatigue was most sensitive to solder layer thickness, with copper ribbon and silicon thickness being the next two most sensitive variables. By simulating both accelerated thermal cycles (ATCs) and PVmore » cell temperature histories through two characteristic days of service, we determined that the acceleration factor between the ATC and outdoor service was independent of the variables sampled in this study. This result implies that an ATC test will represent a similar time of outdoor exposure for a wide range of module designs. This is an encouraging result for the standard ATC that must be universally applied across all modules.« less

  19. Molecular Determinants of Magnesium-Dependent Synaptic Plasticity at Electrical Synapses Formed by Connexin36

    PubMed Central

    Palacios-Prado, Nicolás; Chapuis, Sandrine; Panjkovich, Alejandro; Fregeac, Julien; Nagy, James I.; Bukauskas, Feliksas F.

    2014-01-01

    Neuronal gap junction (GJ) channels composed of connexin36 (Cx36) play an important role in neuronal synchronization and network dynamics. Here we show that Cx36-containing electrical synapses between inhibitory neurons of the thalamic reticular nucleus are bi-directionally modulated by changes in intracellular free magnesium concentration ([Mg2+]i). Chimeragenesis demonstrates that the first extracellular loop of Cx36 contains a Mg2+-sensitive domain, and site-directed mutagenesis shows that the pore-lining residue D47 is critical in determining high Mg2+-sensitivity. Single channel analysis of Mg2+-sensitive chimeras and mutants reveals that [Mg2+]i controls the strength of electrical coupling mostly via gating mechanisms. In addition, asymmetric transjunctional [Mg2+]i induces strong instantaneous rectification, providing a novel mechanism for electrical rectification in homotypic Cx36 GJs. We suggest that Mg2+-dependent synaptic plasticity of Cx36-containing electrical synapses could underlie neuronal circuit reconfiguration via changes in brain energy metabolism that affects neuronal levels of intracellular ATP and [Mg2+]i. PMID:25135336

  20. Evaluation of Aspergillus PCR protocols for testing serum specimens.

    PubMed

    White, P Lewis; Mengoli, Carlo; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Finnstrom, Niklas; Klingspor, Lena; Melchers, Willem J G; McCulloch, Elaine; Barnes, Rosemary A; Donnelly, J Peter; Loeffler, Juergen

    2011-11-01

    A panel of human serum samples spiked with various amounts of Aspergillus fumigatus genomic DNA was distributed to 23 centers within the European Aspergillus PCR Initiative to determine analytical performance of PCR. Information regarding specific methodological components and PCR performance was requested. The information provided was made anonymous, and meta-regression analysis was performed to determine any procedural factors that significantly altered PCR performance. Ninety-seven percent of protocols were able to detect a threshold of 10 genomes/ml on at least one occasion, with 83% of protocols reproducibly detecting this concentration. Sensitivity and specificity were 86.1% and 93.6%, respectively. Positive associations between sensitivity and the use of larger sample volumes, an internal control PCR, and PCR targeting the internal transcribed spacer (ITS) region were shown. Negative associations between sensitivity and the use of larger elution volumes (≥100 μl) and PCR targeting the mitochondrial genes were demonstrated. Most Aspergillus PCR protocols used to test serum generate satisfactory analytical performance. Testing serum requires less standardization, and the specific recommendations shown in this article will only improve performance.

Top