Lin, Jui-Te; Huang, Morris; Sprigle, Stephen
2015-01-01
The purpose of this study was to develop a simple approach to evaluate resistive frictional forces acting on manual wheelchairs (MWCs) during straight and turning maneuvers. Using a dummy-occupied MWC, decelerations were measured via axle-mounted encoders during a coast-down protocol that included straight trajectories and fixed-wheel turns. Eight coast-down trials were conducted to test repeatability and repeated on separate days to evaluate reliability. Without changing the inertia of the MWC system, three tire inflations were chosen to evaluate the sensitivity in discerning deceleration differences using effect sizes. The technique was also deployed to investigate the effect of different MWC masses and weight distributions on resistive forces. Results showed that the proposed coast-down technique had good repeatability and reliability in measuring decelerations and had good sensitivity in discerning differences in tire inflation, especially during turning. The results also indicated that increased loading on drive wheels reduced resistive losses in straight trajectories while increasing resistive losses during turning. During turning trajectories, the presence of tire scrub contributes significantly to the amount of resistive force. Overall, this new coast-down technique demonstrates satisfactory repeatability and sensitivity for detecting deceleration changes during straight and turning trajectories, indicating that it can be used to evaluate resistive loss of different MWC configurations and maneuvers.
A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel
NASA Astrophysics Data System (ADS)
Pathak, Akhilesh Kumar; Singh, Vinod Kumar
2017-12-01
In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.
151-km single-end phase-sensitive optical time-domain reflectometer assisted by optical repeater
NASA Astrophysics Data System (ADS)
Song, Muping; Zhu, Weiji; Xia, Qiaolan; Yin, Cong; Lu, Yan; Wu, Ying; Zhuang, Shouwang
2018-02-01
A phase-sensitive optical time-domain reflectometry (ϕOTDR) system that can detect intrusion over 150 km is presented. The ϕOTDR system uses nonbalanced optical repeaters to extend the sensing distance. The repeater consists of two erbium-doped optical fiber amplifiers (EDFAs) and one Raman amplifier (RA). One EDFA power amplifier amplifies the forward-transmitting pulse, and one EDFA preamplifier is used for the backscattering signal, respectively. The RA helps keeping the power along the fiber stable. The optical repeater is installed at the connection of two adjacent fibers to compensate the power decline due to fiber loss. It is easy to install the repeater midway among the fiber links in the system for longer-distance sensing since there is no need of modifying the original sensing system. The theoretical analysis of the repeater is given to describe its effect on the distributed sensing. In experiments, several ϕOTDR traces show a good agreement with theoretical results. Using the optical repeater, 35-Hz vibration at 151 km is successfully measured with signal-to-noise ratio of 8 dB without extra signal processing.
NASA Astrophysics Data System (ADS)
Hindal, S. S.; Taher, H. J.
2018-05-01
The RH sensor operation based on water vapor adsorption and desorption at the silica-air interface within the PCF. Sensor fabrication is simple; it includes splicing and cleaving the PCF with SMF only. PCF (LMA-10) with a certain length spliced to SMF (Corning-28). The PCFI spectrum exhibits good sensitivity to the variations of humidity. The PCFI response is observed for range of relative humidity values from (27% RH to 85% RH), the interference peaks position is found to be shifted to longer wavelength as the humidity increases. In this work, a 6cm length of PCFs is used, and it shows a sensitivity of (2.41pm / %RH), good repeatability, and reversible in nature. This humidity sensor has distinguished features as that the sensor does not require the use of a hygroscopic material, robust, compact size, immunity to electromagnetic interference, and it has potential applications for high humidity environments.
Validation of a Hartmann-Moiré wavefront sensor with large dynamic range.
Wei, Xin; Van Heugten, Tony; Thibos, Larry
2009-08-03
Our goal was to validate the accuracy, repeatability, sensitivity, and dynamic range of a Hartmann-Moiré (HM) wavefront sensor (PixelOptics, Inc.) designed for ophthalmic applications. Testing apparatus injected a 4 mm diameter monochromatic (532 nm) beam of light into the wavefront sensor for measurement. Controlled amounts of defocus and astigmatism were introduced into the beam with calibrated spherical (-20D to + 18D) and cylindrical (-8D to + 8D) lenses. Repeatability was assessed with three repeated measurements within a 2-minute period. Correlation coefficients between mean wavefront measurements (n = 3) and expected wavefront vergence for both sphere and cylinder lenses were >0.999. For spherical lenses, the sensor was accurate to within 0.1D over the range from -20D to + 18D. For cylindrical lenses, the sensor was accurate to within 0.1D over the range from -8D to + 8D. The primary limitation to demonstrating an even larger dynamic range was the increasingly critical requirements for optical alignment. Sensitivity to small changes of vergence was constant over the instrument's full dynamic range. Repeatability of measurements for fixed condition was within 0.01D. The Hartmann-Moiré wavefront sensor measures defocus and astigmatism accurately and repeatedly with good sensitivity over a large dynamic range required for ophthalmic applications.
NASA Astrophysics Data System (ADS)
Liu, Ying; Tao, Lu-Qi; Wang, Dan-Yang; Zhang, Tian-Yu; Yang, Yi; Ren, Tian-Ling
2017-03-01
In this paper, a flexible, simple-preparation, and low-cost graphene-silk pressure sensor based on soft silk substrate through thermal reduction was demonstrated. Taking silk as the support body, the device had formed a three-dimensional structure with ordered multi-layer structure. Through a simple and low-cost process technology, graphene-silk pressure sensor can achieve the sensitivity value of 0.4 kPa - 1 , and the measurement range can be as high as 140 kPa. Besides, pressure sensor can have a good combination with knitted clothing and textile product. The signal had good reproducibility in response to different pressures. Furthermore, graphene-silk pressure sensor can not only detect pressure higher than 100 kPa, but also can measure weak body signals. The characteristics of high-sensitivity, good repeatability, flexibility, and comfort for skin provide the high possibility to fit on various wearable electronics.
De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal
2016-04-01
In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.
Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu
2013-01-30
Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH(3) gas sensing applications. The MWCNT-based sensor is sensitive to NH(3) gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH(3), compared with alcohol and LPG.
NASA Astrophysics Data System (ADS)
Silva, Ana S.; Catarino, André; Correia, Miguel V.; Frazão, Orlando
2013-12-01
The work presented here describes the development and characterization of intensity fiber optic sensor integrated in a specifically designed piece of garment to measure elbow flexion. The sensing head is based on macrobending incorporated in the garment, and the increase of curvature number was studied in order to investigate which scheme provided a good result in terms of sensitivity and repeatability. Results showed the configuration that assured a higher sensitivity (0.644 dBm/deg) and better repeatability was the one with four loops. Ultimately, this sensor can be used for rehabilitation purposes to monitor human joint angles, namely, elbow flexion on stroke survivors while performing the reach functional task, which is the most common upper-limb human gesture.
Gómez-Ordóñez, Eva; Jiménez-Escrig, Antonio; Rupérez, Pilar
2012-05-15
Biological properties of polysaccharides from seaweeds are related to their composition and structure. Many factors such as the kind of sugar, type of linkage or sulfate content of algal biopolymers exert an influence in the relationship between structure and function. Besides, the molecular weight (MW) also plays an important role. Thus, a simple, reliable and fast HPSEC method with refractive index detection was developed and optimized for the MW estimation of soluble algal polysaccharides. Chromatogram shape and repeatability of retention time was considerably improved when sodium nitrate was used instead of ultrapure water as mobile phase. Pullulan and dextran standards of different MW were used for method calibration and validation. Also, main polysaccharide standards from brown (alginate, fucoidan, laminaran) and red seaweeds (kappa- and iota-carrageenan) were used for quantification and method precision and accuracy. Relative standard deviation (RSD) of repeatability for retention time, peak areas and inter-day precision was below 0.7%, 2.5% and 2.6%, respectively, which indicated good repeatability and precision. Recoveries (96.3-109.8%) also showed its fairly good accuracy. Regarding linearity, main polysaccharide standards from brown or red seaweeds showed a highly satisfactory correlation coefficient (r>0.999). Moreover, a good sensitivity was shown, with corresponding limits of detection and quantitation in mg/mL of 0.05-0.21 and 0.16-0.31, respectively. The method was applied to the MW estimation of standard algal polysaccharides, as well as to the soluble polysaccharide fractions from the brown seaweed Saccharina latissima and the red Mastocarpus stellatus, respectively. Although distribution of molecular weight was broad, the good repeatability for retention time provided a good precision in MW estimation of polysaccharides. Water- and alkali-soluble fractions from S. latissima ranged from very high (>2400 kDa) to low MW compounds (<6 kDa); this high heterogeneity could be attributable to the complex polysaccharide composition of brown algae. Regarding M. stellatus, sulfated galactans followed a descending order of MW (>1400 kDa to <10 kDa), related to the different solubility of carrageenans in red seaweeds. In summary, the method developed allows for the molecular weight analysis of seaweed polysaccharides with very good precision, accuracy, linearity and sensitivity within a short time. Copyright © 2012 Elsevier B.V. All rights reserved.
Ionic pH and glucose sensors fabricated using hydrothermal ZnO nanostructures
NASA Astrophysics Data System (ADS)
Wang, Jyh-Liang; Yang, Po-Yu; Hsieh, Tsang-Yen; Juan, Pi-Chun
2016-01-01
Hydrothermally synthesized aluminum-doped ZnO (AZO) nanostructures have been adopted in extended-gate field-effect transistor (EGFET) sensors to demonstrate the sensitive and stable pH and glucose sensing characteristics of AZO-nanostructured EGFET sensors. The AZO-nanostructured EGFET sensors exhibited the following superior pH sensing characteristics: a high current sensitivity of 0.96 µA1/2/pH, a high linearity of 0.9999, less distortion of output waveforms, a small hysteresis width of 4.83 mV, good long-term repeatability, and a wide sensing range from pHs 1 to 13. The glucose sensing characteristics of AZO-nanostructured biosensors exhibited the desired sensitivity of 60.5 µA·cm-2·mM-1 and a linearity of 0.9996 up to 13.9 mM. The attractive characteristics of high sensitivity, high linearity, and repeatability of using ionic AZO-nanostructured EGFET sensors indicate their potential use as electrochemical and disposable biosensors.
Repetitive Elements May Comprise Over Two-Thirds of the Human Genome
de Koning, A. P. Jason; Gu, Wanjun; Castoe, Todd A.; Batzer, Mark A.; Pollock, David D.
2011-01-01
Transposable elements (TEs) are conventionally identified in eukaryotic genomes by alignment to consensus element sequences. Using this approach, about half of the human genome has been previously identified as TEs and low-complexity repeats. We recently developed a highly sensitive alternative de novo strategy, P-clouds, that instead searches for clusters of high-abundance oligonucleotides that are related in sequence space (oligo “clouds”). We show here that P-clouds predicts >840 Mbp of additional repetitive sequences in the human genome, thus suggesting that 66%–69% of the human genome is repetitive or repeat-derived. To investigate this remarkable difference, we conducted detailed analyses of the ability of both P-clouds and a commonly used conventional approach, RepeatMasker (RM), to detect different sized fragments of the highly abundant human Alu and MIR SINEs. RM can have surprisingly low sensitivity for even moderately long fragments, in contrast to P-clouds, which has good sensitivity down to small fragment sizes (∼25 bp). Although short fragments have a high intrinsic probability of being false positives, we performed a probabilistic annotation that reflects this fact. We further developed “element-specific” P-clouds (ESPs) to identify novel Alu and MIR SINE elements, and using it we identified ∼100 Mb of previously unannotated human elements. ESP estimates of new MIR sequences are in good agreement with RM-based predictions of the amount that RM missed. These results highlight the need for combined, probabilistic genome annotation approaches and suggest that the human genome consists of substantially more repetitive sequence than previously believed. PMID:22144907
Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu
2013-01-01
Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH3 gas sensing applications. The MWCNT-based sensor is sensitive to NH3 gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH3, compared with alcohol and LPG. PMID:23364198
Enhancement of humidity sensitivity of graphene through functionalization with polyethylenimine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ben Aziza, Zeineb; School of Electrical and Electronics Engineering, Nanyang Technological University, Block S1, 50 Nanyang Avenue, Singapore 639798; XLIM UMR 7252 Université de Limoges/CNRS, 123 Avenue Albert Thomas, 87060 Limoges
2015-09-28
In this work, we show that the sensing performance of graphene based humidity sensors can be largely improved through polymer functionalization. Chemical vapor deposited graphene is functionalized with amine rich polymer, leading to electron transfer from amine groups in the polymer to graphene. The functionalized graphene humidity sensor has demonstrated good sensitivity, recovery, and repeatability. Charge transfer between the functionalized graphene and water molecules and the sensing mechanism are studied systemically using field effect transistor geometry and scanning Kelvin probe microscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Y; Fuller, C; Mohamed, A
2015-06-15
Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients weremore » scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.« less
Assessment of different methods to estimate bovine colostrum quality on farm.
Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D
2016-09-01
To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.
A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching
Rodger A. Arola
1968-01-01
Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...
De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie
2016-01-01
Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.
Thirumalraj, Balamurugan; Palanisamy, Selvakumar; Chen, Shen-Ming; Lou, Bih-Show
2016-01-15
The research community has continuously paid much attention on the preparation of hybrid of carbon nanomaterials owing to combine their unique properties. Herein, we report the preparation of highly stable fullerene C60 (C60) wrapped graphene oxide (GO) nanocomposite by using a simple sonication method. The fabricated GO-C60 nanocomposite modified glassy carbon electrode shows a good sensitivity and lower oxidation overpotential towards dopamine (DA) than that of pristine GO and C60. The fabricated sensor detects the DA in the linear response range of 0.02-73.5μM. The limit of detection is estimated to be 0.008μM based on 3σ with a sensitivity of 4.23μAμM(-1)cm(-2). The fabricated sensor also exhibits other features such as good selectivity, stability, reproducibility and repeatability. The proposed sensor exhibits good practicality towards the detection of DA in rat brain and commercial DA injection samples. Copyright © 2015 Elsevier Inc. All rights reserved.
Photoacoustics of disperse systems: Below cavitation threshold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egerev, Sergey; Ovchinnikov, Oleg
2012-05-24
The paper considers photoacoustic (PA) conversion while irradiating suspensions in extra-small volume probes with laser pulses having small fluence values. Only linear and nonlinear thermooptical laser sound generation regimes were observed. Thus, good repeatability of acoustic signal parameters informative about probe content was achieved. The experiment conducted has shown how one can avoid the decrease of particles detection sensitivity for the thermooptical mode.
Gao, Miaomiao; Wei, Cong; Lin, Xianqing; Liu, Yuan; Hu, Fengqin; Zhao, Yong Sheng
2017-03-09
We demonstrate the fabrication of organic high Q active whispering-gallery-mode (WGM) resonators from π-conjugated polymer by a controlled emulsion-solvent-evaporation method, which can simultaneously provide optical gain and act as an effective resonant cavity. By measuring the shift of their lasing modes on exposure to organic vapor, we successfully monitored the slight concentration variation in the chemical gas. These microlaser sensors demonstrated high detection sensitivity and good signal repeatability under continuous chemical gas treatments. The results offer an effective strategy to design miniaturized optical sensors.
de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A
2018-05-01
This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.
Ternesten-Hasséus, Ewa; Lowhagen, Olle; Millqvist, Eva
2007-01-01
Objective It is common in asthma and allergy clinics to see patients presenting with upper and lower airway symptoms that are induced by chemicals and scents and not explained by allergic or asthmatic reactions. Previous studies have shown that these patients often have increased cough sensitivity to inhaled capsaicin; such sensitivity is known to reflect the airway sensory reactivity. The aim of this study was to evaluate the duration of symptoms induced by chemicals and scents and to measure health-related quality of life (HRQL) in patients with chemically induced airway symptoms. We also wished to determine and compare repeatability of the cough response to capsaicin inhalation, and to evaluate the patients’ airway sensory reactivity in a long-term perspective. Participants Seventeen patients with a history of at least 12 months of airway symptoms induced by chemicals and scents were followed over 5 years with repeated questionnaires, measurements of HRQL, and capsaicin inhalation tests. Results The symptoms persisted and did not change significantly over time, and the patients had a reduced HRQL that did not change during the 5-year period. The capsaicin sensitivity was increased at the start of the study, the cough sensitivity was long-lasting, and the repeatability of the capsaicin inhalation test was considered to be good in a long-term perspective. Conclusions Upper and lower airway symptoms induced by chemicals and scents represent an entity of chronic diseases, different from asthma or chronic obstructive pulmonary disease, with persistent symptoms, a reduced HRQL, and unchanged sensory hyperreactivity. PMID:17431493
Micro-structured femtosecond laser assisted FBG hydrogen sensor.
Karanja, Joseph Muna; Dai, Yutang; Zhou, Xian; Liu, Bin; Yang, Minghong
2015-11-30
We discuss hydrogen sensors based on fiber Bragg gratings (FBGs) micro-machined by femtosecond laser to form microgrooves and sputtered with Pd/Ag composite film. The atomic ratio of the two metals is controlled at Pd:Ag = 3:1. At room temperature, the hydrogen sensitivity of the sensor probe micro-machined by 75 mW laser power and sputtered with 520 nm of Pd/Ag film is 16.5 pm/%H. Comparably, the standard FBG hydrogen sensitivity becomes 2.5 pm/%H towards the same 4% hydrogen concentration. At an ambient temperature of 35°C, the processed sensor head has a dramatic rise in hydrogen sensitivity. Besides, the sensor shows good response and repeatability during hydrogen concentration test.
Differential genetic susceptibility to child risk at birth in predicting observed maternal behavior.
Fortuna, Keren; van Ijzendoorn, Marinus H; Mankuta, David; Kaitz, Marsha; Avinun, Reut; Ebstein, Richard P; Knafo, Ariel
2011-01-01
This study examined parenting as a function of child medical risks at birth and parental genotype (dopamine D4 receptor; DRD4). Our hypothesis was that the relation between child risks and later maternal sensitivity would depend on the presence/absence of a genetic variant in the mothers, thus revealing a gene by environment interaction (GXE). Risk at birth was defined by combining risk indices of children's gestational age at birth, birth weight, and admission to the neonatal intensive care unit. The DRD4-III 7-repeat allele was chosen as a relevant genotype as it was recently shown to moderate the effect of environmental stress on parental sensitivity. Mothers of 104 twin pairs provided DNA samples and were observed with their children in a laboratory play session when the children were 3.5 years old. Results indicate that higher levels of risk at birth were associated with less sensitive parenting only among mothers carrying the 7-repeat allele, but not among mothers carrying shorter alleles. Moreover, mothers who are carriers of the 7-repeat allele and whose children scored low on the risk index were observed to have the highest levels of sensitivity. These findings provide evidence for the interactive effects of genes and environment (in this study, children born at higher risk) on parenting, and are consistent with a genetic differential susceptibility model of parenting by demonstrating that some parents are inherently more susceptible to environmental influences, both good and bad, than are others.
Vieira, F P; Mesquita, T L; Lara, P C P; Ramaldes, G A; Beinner, M A; Silva, J B B; Oliveira, M C; Silveira, J N
2013-10-01
In this work, stability and the pH-sensitivity of pH-sensitive stealth liposomes containing cisplatin exposed to plasma medium and their subsequent responses to pH modifications were evaluated. A method to determine platin in mouse plasma by electrothermal atomic absorption spectroscopy (ET AAS) was developed and validated. At first, a comparative study of sample preparation treatments with basic, acidic, and acidic added with Triton X-100 as a modifier was done. The best treatment was obtained with HCl 3% (v/v). The ET AAS method with acid treatment presented linearity at a range of 10-160 ng Pt/mL. The limits of detection (LOD) was 3.1 ng/mL Pt for acid treatment, while the limit quantification (LOQ) was 10 ng/mL Pt. The acid treatment presented good repeatability (VC<15.0%) and recovery close to 100%. This treatment was chosen for subsequent studies due to its best value of repeatability, recovery, LOD and lowest cost. pH-sensitive stealth liposomes, containing cisplatin, demonstrated low stability and poor response to pH variation after plasma incubation. These findings suggest that further studies are needed to improve liposome formulation i.e., to reduce its size. Copyright © 2013 Elsevier B.V. All rights reserved.
Preparation of surface enhanced Raman substrate and its characterization
NASA Astrophysics Data System (ADS)
Liu, Y.; Wang, J. Y.; Wang, J. Q.
2017-10-01
Surface enhanced Raman spectroscopy (SERS) is a fast, convenient and highly sensitive detection technique, and preparing the good effect and repeatable substrate is the key to realize the trace amount and quantitative detection in the field of food safety detection. In this paper, a surface enhanced Raman substrate based on submicrometer silver particles structure was prepared by chemical deposition method, and characterized its structure and optical properties.
NASA Astrophysics Data System (ADS)
Razak, N. A.; Hamida, B. A.; Irawati, N.; Habaebi, M. H.
2017-06-01
Adiabaticity is one of the essential criteria in producing good fabricated tapered fibers. Good tapered fibers can be use in sensor application such as humidity sensor, temperature sensor and refractive index sensor. In this paper, good tapering silica fiber is produced by using flame brushing technique and then, the microfiber is coated with polymer Polyaniline (PAni) to sense different type of alcohols with different concentrations. The outcome of this experiment gives excellent repeatability in the detection of alcohol sensing with a sensitivity of 0.1332 μW/% and a resolution of 3.764%. In conclusion, conducting polymer coated optical microfiber sensor for alcohol detection with low cost, effective and simple set-up was successfully achieved in this study.
A case of high noise sensitivity
NASA Astrophysics Data System (ADS)
Murata, M.; Sakamoto, H.
1995-10-01
A case of noise sensitivity with a five-year follow-up period is reported. The patient was a 34-year-old single man who was diagnosed as having psychosomatic disorder triggered by two stressful life events in rapid succession with secondary hypersensitivity to noise. Hypersensitivity to light and cold also developed later in the clinical course. The auditory threshold was within the normal range. The discomfort threshold as a measure of the noise sensitivity secondary to mental illness was measured repeatedly using test tone of audiometry. The discomfort threshold varied depending upon his mental status, ranging from 40-50 dB in the comparatively poorer mental state to 70-95 dB in the relatively good mental state. The features of noise sensitivity, including that secondary to mental illness, are discussed.
RGO-coated elastic fibres as wearable strain sensors for full-scale detection of human motions
NASA Astrophysics Data System (ADS)
Mi, Qing; Wang, Qi; Zang, Siyao; Mao, Guoming; Zhang, Jinnan; Ren, Xiaomin
2018-01-01
In this study, we chose highly-elastic fabric fibres as the functional carrier and then simply coated the fibres with reduced graphene oxide (rGO) using plasma treatment, dip coating and hydrothermal reduction steps, finally making a wearable strain sensor. As a result, the full-scale detection of human motions, ranging from bending joints to the pulse beat, has been achieved by these sensors. Moreover, high sensitivity, good stability and excellent repeatability were realized. The good sensing performances and economical fabrication process of this wearable strain sensor have strengthened our confidence in practical applications in smart clothing, smart fabrics, healthcare, and entertainment fields.
NASA Astrophysics Data System (ADS)
Pachava, Vengal Rao; Kamineni, Srimannarayana; Madhuvarasu, Sai Shankar; Putha, Kishore; Mamidi, Venkata Reddy
2015-12-01
A fiber Bragg grating (FBG) pressure sensor with high sensitivity and resolution has been designed and demonstrated. The sensor is configured by firmly fixing the FBG with a metal bellows structure. The sensor works by means of measuring the Bragg wavelength shift of the FBG with respect to pressure change. From the experimental results, the pressure sensitivity of the sensor is found to be 90.6 pm/psi, which is approximately 4000 times as that of a bare fiber Bragg grating. A very good linearity of 99.86% is observed between the Bragg wavelength of the FBG and applied pressure. The designed sensor shows good repeatability with a negligible hysteresis error of ± 0.29 psi. A low-cost interrogation system that includes a long period grating (LPG) and a photodiode (PD) accompanied with simple electronic circuitry is demonstrated for the FBG sensor, which enables the sensor to attain high resolution of up to 0.025 psi. Thermal-strain cross sensitivity of the FBG pressure sensor is compensated using a reference FBG temperature sensor. The designed sensor can be used for liquid level, specific gravity, and static/dynamic low pressure measurement applications.
Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.
2010-01-01
There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812
Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu
2013-07-01
In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Siaï, A.; Haro-González, P.; Horchani Naifer, K.; Férid, M.
2018-02-01
The investigation of the fluorescence intensity ratio and the lifetime thermometry techniques for two rare earth perovskites-type oxide (LaGdO3:Er3+ and LaGdO3:Er3+/Yb3+) has been carried out. We have demonstrated that the intensity ratio of thermally coupled levels of erbium (2H11/2 and 4S3/2) is temperature dependant in the range from 283 to 393 K. The sensitivity parameter was found to reach a maximum value of 31 × 10-4 K-1 and 34 × 10-4 K-1 at 393 K and the temperature resolution to be equivalent to 1.61 and 3.1 K, for Er3+ and Er3+/Yb3+ doped oxide, respectively. By studying the temperature dependence of the normalized lifetimes in the range from 293 to 348 K, we proved that the sensitivity of the green emission (4S3/2) is higher than the red one (4F9/2) for both samples, and that it increases from 144 × 10-4 K-1 for LaGdO3:Er3+ to 179 × 10-4 K-1 for LaGdO3:Er3+/Yb3+. The thermal coefficients were quite large in comparison to those calculated for different luminescent materials and reported in literature. The repeatability of measurements was tested by performing heating and cooling cycles for both methods and the results show that these optical techniques have a good repeatability performance. Hence, the LaGdO3: Er3+, Yb3+ oxide has a precise and a satisfying sensitivity associated to a good thermal and chemical stability, suggesting that it can be a potential candidate in temperature sensing.
NASA Astrophysics Data System (ADS)
Kishore, P. V. N.; Sai Shankar, M.
2017-04-01
This paper describes a fiber optics based pH sensor by using wavelength modulated techniques. Fiber Bragg grating (FBG) is functionalized with a stimulus responsive hydrogel which induces a strain on FBG due to mechanical expansion of the gel in response to ambient pH changes. The gel is synthesized from the blends of Poly (vinyl alcohol)/Poly (acrylic acid). The induced strain results in a shift of FBG reflected peak which is monitored by an interrogator. The sensor system shows a good linearity in acidic pH range of 3 to 7 with a sensitivity of 12.16pm/pH. Besides that it shows good repeatability which proves it to be fit for pH sensing applications.
Hydrogel-coated fiber Bragg grating sensor for pH monitoring
NASA Astrophysics Data System (ADS)
Pabbisetti, Vayu Nandana Kishore; Madhuvarasu, Sai Shankar
2016-06-01
We present a fiber-optic wavelength-modulated sensor for pH applications. Fiber Bragg grating (FBG) is functionalized with a stimulus-responsive hydrogel that induces a strain on FBG due to mechanical expansion of the gel in response to ambient pH changes. The gel is synthesized from the blends of poly (vinyl alcohol)/poly (acrylic acid). The induced strain results in a shift of FBG reflected peak that is monitored by an interrogator. The sensor system shows good linearity in the acidic pH range of 3 to 7 with a sensitivity of 12.16 pm/pH. In addition, it shows good repeatability and oscillator behavior, which proves it to be fit for pH sensing applications.
Comparison of algorithms of testing for use in automated evaluation of sensation.
Dyck, P J; Karnes, J L; Gillen, D A; O'Brien, P C; Zimmerman, I R; Johnson, D M
1990-10-01
Estimates of vibratory detection threshold may be used to detect, characterize, and follow the course of sensory abnormality in neurologic disease. The approach is especially useful in epidemiologic and controlled clinical trials. We studied which algorithm of testing and finding threshold should be used in automatic systems by comparing among algorithms and stimulus conditions for the index finger of healthy subjects and for the great toe of patients with mild neuropathy. Appearance thresholds obtained by linear ramps increasing at a rate less than 4.15 microns/sec provided accurate and repeatable thresholds compared with thresholds obtained by forced-choice testing. These rates would be acceptable if only sensitive sites were studied, but they were too slow for use in automatic testing of insensitive parts. Appearance thresholds obtained by fast linear rates (4.15 or 16.6 microns/sec) overestimated threshold, especially for sensitive parts. Use of the mean of appearance and disappearance thresholds, with the stimulus increasing exponentially at rates of 0.5 or 1.0 just noticeable difference (JND) units per second, and interspersion of null stimuli, Békésy with null stimuli, provided accurate, repeatable, and fast estimates of threshold for sensitive parts. Despite the good performance of Békésy testing, we prefer forced choice for evaluation of the sensation of patients with neuropathy.
NASA Astrophysics Data System (ADS)
Di, Weihua; Zhang, Xiang; Qin, Weiping
2017-04-01
The rapid, sensitive and selective detection of glutathione (GSH) is of great importance in the biological systems. In this work, a template-free and one-step method was used to synthesize the single-layer MnO2 nanosheets via a redox reaction. The resulting product was characterized by XRD, TEM, FTIR, XPS and UV-vis absorption. The addition of GSH results in the change of solution color depth owing to the occurrence of a redox reaction between MnO2 and GSH, enabling colorimetric detection of GSH. At a pH of 3.6, the proposed sensor gives a linear calibration over a GSH concentration range of 10-100 μM, with a rapid response of less than 2 min and a low detection limit of 0.5 μM. The relative standard deviation for seven repeated determinations of GSH is lower than 5.6%. Furthermore, the chemical response of the synthesized MnO2 nanosheets toward GSH is selective. Owing to the advantages with good water solubility, rapid response, high sensitivity, good biocompatibility and operation simplicity, this two-dimensional MnO2-based sensing material might be potential for detecting GSH in biological applications.
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-04-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.
Hyttel-Sorensen, Simon; Hessel, Trine Witzner; Greisen, Gorm
2014-04-01
Estimation of regional tissue oxygenation (rStO2) by near infrared spectroscopy enables non-invasive end-organ oxygen balance monitoring and could be a valuable tool in intensive care. However, the diverse absolute values and dynamics of different devices, and overall poor repeatability of measurements are a problem. The aim of the present study is to test the hypothesis that INVOS 5100C, FORE-SIGHT and NONIN EQUANOX 7600 have similar properties concerning absolute values, repeatability, and sensitivity to changes in rStO2. To test repeatability the sensors were repositioned 20 times during hemodynamic steady state on the adult forearm. Afterwards six vascular occlusions by inflation of an upper arm cuff were done to achieve low oxygenation in the forearm. Absolute values were compared by repeated-measures ANOVA, repeatability was estimated by the within-subject standard deviation, Sw, and response to changing oxygenation by the down slope of rStO2 during vascular occlusion in the respective arm. 10 healthy adults, 21-29 years old, with double skinfolds on the forearm less than 10 mm participated. The median rStO2 was 70.7% (interquartile range (IQR) 7.7%), 68.4% (IQR 8.4%), and 64.6% (IQR 4.8) with INVOS, NONIN, and FORE-SIGHT, respectively, the median rate of decline was 13.2%/min (IQR 9.6), 22.8 %/min (IQR 18.0), and 10.8%/min (IQR 6.0), and the same-site repeatability was 2.9% (95% CI 2.4-3.3), 4.6% (CI 3.9-5.3), and 2.0% (CI 1.7-2.3). INVOS gave significantly higher steady state values than FORE-SIGHT, and NONIN had the steepest decline in rStO2, but the poorest repeatability. Two measures of signal-to-noise were similar among devices. This suggests that good repeatability comes at the expense of low sensitivity to changes in oxygenation. Values of rStO2 on the forearm from INVOS, NONIN and FORE-SIGTH cannot be used interchangeably.
Repeatability and comparison of clinical techniques for anterior chamber angle assessment.
Campbell, Peter; Redmond, Tony; Agarwal, Rishi; Marshall, Lewis R; Evans, Bruce J W
2015-03-01
To assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. Gonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1 month apart, on 80 subjects aged over 40 years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840 nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa (κ) was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. Measurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair κ = 0.29, while that of the van Herick method (κ = 0.54) and AS-OCT (κ = 0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). Intra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more precise classifications. These instruments are not widely used by optometrists in clinical practice in the UK at present. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.
Correlation between experimental human and murine skin sensitization induction thresholds.
Api, Anne Marie; Basketter, David; Lalko, Jon
2015-01-01
Quantitative risk assessment for skin sensitization is directed towards the determination of levels of exposure to known sensitizing substances that will avoid the induction of contact allergy in humans. A key component of this work is the predictive identification of relative skin sensitizing potency, achieved normally by the measurement of the threshold (the "EC3" value) in the local lymph node assay (LLNA). In an extended series of studies, the accuracy of this murine induction threshold as the predictor of the absence of a sensitizing effect has been verified by conduct of a human repeated insult patch test (HRIPT). Murine and human thresholds for a diverse set of 57 fragrance chemicals spanning approximately four orders of magnitude variation in potency have been compared. The results confirm that there is a useful correlation, with the LLNA EC3 value helping particularly to identify stronger sensitizers. Good correlation (with half an order of magnitude) was seen with three-quarters of the dataset. The analysis also helps to identify potential outlier types of (fragrance) chemistry, exemplified by hexyl and benzyl salicylates (an over-prediction) and trans-2-hexenal (an under-prediction).
Construction of MoS2/Si nanowire array heterojunction for ultrahigh-sensitivity gas sensor
NASA Astrophysics Data System (ADS)
Wu, Di; Lou, Zhenhua; Wang, Yuange; Xu, Tingting; Shi, Zhifeng; Xu, Junmin; Tian, Yongtao; Li, Xinjian
2017-10-01
Few-layer MoS2 thin films were synthesized by a two-step thermal decomposition process. In addition, MoS2/Si nanowire array (SiNWA) heterojunctions exhibiting excellent gas sensing properties were constructed and investigated. Further analysis reveals that such MoS2/SiNWA heterojunction devices are highly sensitive to nitric oxide (NO) gas under reverse voltages at room temperature (RT). The gas sensor demonstrated a minimum detection limit of 10 ppb, which represents the lowest value obtained for MoS2-based sensors, as well as an ultrahigh response of 3518% (50 ppm NO, ˜50% RH), with good repeatability and selectivity of the MoS2/SiNWA heterojunction. The sensing mechanisms were also discussed. The performance of the MoS2/SiNWA heterojunction gas sensors is superior to previous results, revealing that they have great potential in applications relating to highly sensitive gas sensors.
Construction of MoS2/Si nanowire array heterojunction for ultrahigh-sensitivity gas sensor.
Wu, Di; Lou, Zhenhua; Wang, Yuange; Xu, Tingting; Shi, Zhifeng; Xu, Junmin; Tian, Yongtao; Li, Xinjian
2017-10-27
Few-layer MoS 2 thin films were synthesized by a two-step thermal decomposition process. In addition, MoS 2 /Si nanowire array (SiNWA) heterojunctions exhibiting excellent gas sensing properties were constructed and investigated. Further analysis reveals that such MoS 2 /SiNWA heterojunction devices are highly sensitive to nitric oxide (NO) gas under reverse voltages at room temperature (RT). The gas sensor demonstrated a minimum detection limit of 10 ppb, which represents the lowest value obtained for MoS 2 -based sensors, as well as an ultrahigh response of 3518% (50 ppm NO, ∼50% RH), with good repeatability and selectivity of the MoS 2 /SiNWA heterojunction. The sensing mechanisms were also discussed. The performance of the MoS 2 /SiNWA heterojunction gas sensors is superior to previous results, revealing that they have great potential in applications relating to highly sensitive gas sensors.
Agarose coated spherical micro resonator for humidity measurements.
Mallik, Arun Kumar; Liu, Dejun; Kavungal, Vishnu; Wu, Qiang; Farrell, Gerald; Semenova, Yuliya
2016-09-19
A new type of fiber optic relative humidity (RH) sensor based on an agarose coated silica microsphere resonator is proposed and experimentally demonstrated. Whispering gallery modes (WGMs) in the micro resonator are excited by evanescent coupling using a tapered fiber with ~3.3 µm waist diameter. A change in the relative humidity of the surrounding the resonator air induces changes in the refractive index (RI) and thickness of the Agarose coating layer. These changes in turn lead to a spectral shift of the WGM resonances, which can be related to the RH value after a suitable calibration. Studies of the repeatability, long-term stability, measurement accuracy and temperature dependence of the proposed sensor are carried out. The RH sensitivity of the proposed sensor depends on the concentration of the agarose gel which determines the initial thickness of the deposited coating layer. Studies of the micro- resonators with coating layers fabricated from gels with three different Agarose concentrations of 0.5%, 1.125% and 2.25 wt./vol.% showed that an increase in the initial thickness of the coating material results in an increase in sensitivity but also leads to a decrease of quality factor (Q) of the micro resonator. The highest sensitivity achieved in our experiments was 518 pm/%RH in the RH range from 30% to 70%. The proposed sensor offers the advantages of a very compact form factor, low hysteresis, good repeatability, and low cross sensitivity to temperature.
Effects of blur and repeated testing on sensitivity estimates with frequency doubling perimetry.
Artes, Paul H; Nicolela, Marcelo T; McCormick, Terry A; LeBlanc, Raymond P; Chauhan, Balwantray C
2003-02-01
To investigate the effect of blur and repeated testing on sensitivity with frequency doubling technology (FDT) perimetry. One eye of 12 patients with glaucoma (mean deviation [MD] mean, -2.5 dB, range +0.5 to -4.3 dB) and 11 normal control subjects underwent six consecutive tests with the FDT N30 threshold program in each of two sessions. In session 1, blur was induced by trial lenses (-6.00, -3.00, 0.00, +3.00, and +6.00 D, in random order). In session 2, only the effects of repeated testing were evaluated. The MD and pattern standard deviation (PSD) indices were evaluated as functions of blur and of test order. By correcting the data of session 1 for the reduction of sensitivity with repeated testing (session 2), the effect of blur on FDT sensitivities was established, and its clinical consequences evaluated on total- and pattern-deviation probability maps. FDT sensitivities decreased with blur (by <0.5 dB/D) and with repeated testing (by approximately 2 dB between the first and sixth tests). Blur and repeated testing independently led to larger numbers of locations with significant total and pattern deviation. Sensitivity reductions were similar in normal control subjects and patients with glaucoma, at central and peripheral test locations and at locations with high and low sensitivities. However, patients with glaucoma showed larger deterioration in the total-deviation-probability maps. To optimize the performance of the device, refractive errors should be corrected and immediate retesting avoided. Further research is needed to establish the cause of sensitivity loss with repeated FDT testing.
Enhanced Sensitivity of Wireless Chemical Sensor Based on Love Wave Mode
NASA Astrophysics Data System (ADS)
Wang, Wen; Oh, Haekwan; Lee, Keekeun; Yang, Sangsik
2008-09-01
A 440 MHz wireless and passive Love-wave-based chemical sensor was developed for CO2 detection. The developed device was composed of a reflective delay line patterned on 41° YX LiNbO3 piezoelectric substrate, a poly(methyl methacrylate) (PMMA) waveguide layer, and Teflon AF 2400 sensitive film. A theoretical model is presented to describe wave propagation in Love wave devices with large piezoelectricity and to allow the design of an optimized structure. In wireless device testing using a network analyzer, infusion of CO2 into the testing chamber induced large phase shifts of the reflection peaks owing to the interaction between the sensing film and the test gas (CO2). Good linearity and repeatability were observed at CO2 concentrations of 0-350 ppm. The obtained sensitivity from the Love wave device was approximately 7.07° ppm-1. The gas response properties of the fabricated Love-wave sensor in terms of linearity and sensitivity were provided, and a comparison to surface acoustic wave devices was also discussed.
Costa, Daryne L M G; Rinaldo, Daniel; Varanda, Eliana A; de Sousa, Juliana F; Nasser, Ana L M; Silva, Ana C Z; Baldoqui, Débora C; Vilegas, Wagner; dos Santos, Lourdes Campaner
2014-10-01
It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography-diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83-107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine.
Costa, Daryne L.M.G.; Rinaldo, Daniel; Varanda, Eliana A.; de Sousa, Juliana F.; Nasser, Ana L.M.; Silva, Ana C.Z.; Baldoqui, Débora C.; Vilegas, Wagner
2014-01-01
Abstract It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography–diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83–107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine. PMID:25055245
Validity and reliability of a novel measure of activity performance and participation.
Murgatroyd, Phil; Karimi, Leila
2016-01-01
To develop and evaluate an innovative clinician-rated measure, which produces global numerical ratings of activity performance and participation. Repeated measures study with 48 community-dwelling participants investigating clinical sensibility, comprehensiveness, practicality, inter-rater reliability, responsiveness, sensitivity and concurrent validity with Barthel Index. Important clinimetric characteristics including comprehensiveness and ease of use were rated >8/10 by clinicians. Inter-rater reliability was excellent on the summary scores (intraclass correlation of 0.95-0.98). There was good evidence that the new outcome measure distinguished between known high and low functional scoring groups, including both responsiveness to change and sensitivity at the same time point in numerous tests. Concurrent validity with the Barthel Index was fair to high (Spearman Rank Order Correlation 0.32-0.85, p > 0.05). The new measure's summary scores were nearly twice as responsive to change compared with the Barthel Index. Other more detailed data could also be generated by the new measure. The Activity Performance Measure is an innovative outcome instrument that showed good clinimetric qualities in this initial study. Some of the results were strong, given the sample size, and further trial and evaluation is appropriate. Implications for Rehabilitation The Activity Performance Measure is an innovative outcome measure covering activity performance and participation. In an initial evaluation, it showed good clinimetric qualities including responsiveness to change, sensitivity, practicality, clinical sensibility, item coverage, inter-rater reliability and concurrent validity with the Barthel Index. Further trial and evaluation is appropriate.
NASA Astrophysics Data System (ADS)
Li, Zhe; Chang, Wenhan; Gao, Chengchen; Hao, Yilong
2018-04-01
In this paper, a novel five-wire micro-fabricated anemometer with 3D directionality based on calorimetric principle is proposed, which is capable of measuring low speed airflow. This structure is realized by vertically bonding two different dies, which can be fabricated on the same wafer resulting in a simple fabrication process. Experiments on speed lower than 200 mm s-1 are conducted, showing good repeatability and directionality. The speed of airflow is controlled by the volumetric flow rate. The measured velocity sensitivity is 9.4 mV · s m-1, with relative direction sensitivity of 37.1 dB. The deviation between the expected and the measured directivity is analyzed by both theories and simulations. A correction procedure is proposed and turns out to be useful to eliminate this deviation. To further explore the potential of our device, we expose it to acoustic plane waves in a standing wave tube, showing consistent planar directivity of figure of eight. The measured velocity sensitivity at 1 kHz and 120 dBC is 4.4 mV · s m-1, with relative direction sensitivity of 27.0 dB. By using the correction method proposed above, the maximum angle error is about ±2°, showing its good directionality accuracy.
Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna
2017-01-01
This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063
Sayago, Isabel; Matatagui, Daniel; Fernández, María Jesús; Fontecha, José Luis; Jurewicz, Izabela; Garriga, Rosa; Muñoz, Edgar
2016-02-01
A Love-wave device with graphene oxide (GO) as sensitive layer has been developed for the detection of chemical warfare agent (CWA) simulants. Sensitive films were fabricated by airbrushing GO dispersions onto Love-wave devices. The resulting Love-wave sensors detected very low CWA simulant concentrations in synthetic air at room temperature (as low as 0.2 ppm for dimethyl-methylphosphonate, DMMP, a simulant of sarin nerve gas, and 0.75 ppm for dipropylene glycol monomethyl ether, DPGME, a simulant of nitrogen mustard). High responses to DMMP and DPGME were obtained with sensitivities of 3087 and 760 Hz/ppm respectively. Very low limit of detection (LOD) values (9 and 40 ppb for DMMP and DPGME, respectively) were calculated from the achieved experimental data. The sensor exhibited outstanding sensitivity, good linearity and repeatability to all simulants tested. The detection mechanism is here explained in terms of hydrogen bonding formation between the tested CWA simulants and GO. Copyright © 2015 Elsevier B.V. All rights reserved.
Stretchable Platinum Network-Based Transparent Electrodes for Highly Sensitive Wearable Electronics.
Wang, Yuting; Cheng, Jing; Xing, Yan; Shahid, Muhammad; Nishijima, Hiroki; Pan, Wei
2017-07-01
A platinum network-based transparent electrode has been fabricated by electrospinning. The unique nanobelt structured electrode demonstrates low sheet resistance (about 16 Ω sq -1 ) and high transparency of 80% and excellent flexibility. One of the most interesting demonstrations of this Pt nanobelt electrode is its excellent reversibly resilient characteristic. The electric conductivity of the flexible Pt electrode can recover to its initial value after 160% extending and this performance is repeatable and stable. The good linear relationship between the resistance and strain of the unique structured Pt electrode makes it possible to assemble a wearable high sensitive strain sensor. Present reported Pt nanobelt electrode also reveals potential applications in electrode for flexible fuel cells and highly transparent ultraviolet (UV) sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wan, Hao; Yin, Heyu; Mason, Andrew J.
2016-01-01
Intense study on gas sensors has been conducted to implement fast gas sensing with high sensitivity, reliability and long lifetime. This paper presents a rapid amperometric method for gas sensing based on a room temperature ionic liquid electrochemical gas sensor. To implement a miniaturized sensor with a fast response time, a three electrode system with gold interdigitated electrodes was fabricated by photolithography on a porous polytetrafluoroethylene substrate that greatly enhances gas diffusion. Furthermore, based on the reversible reaction of oxygen, a new transient double potential amperometry (DPA) was explored for electrochemical analysis to decrease the measurement time and reverse reaction by-products that could cause current drift. Parameters in transient DPA including oxidation potential, oxidation period, reduction period and sample point were investigated to study their influence on the performance of the sensor. Oxygen measurement could be accomplished in 4 s, and the sensor presented a sensitivity of 0.2863 μA/[%O2] and a linearity of 0.9943 when tested in air samples with different oxygen concentrations. Repeatability and long-term stability were also investigated, and the sensor was shown to exhibit good reliability. In comparison to conventional constant potential amperometry, transient DPA was shown to reduce relative standard deviation by 63.2%. With transient DPA, the sensitivity, linearity, repeatability, measurement time and current drift characteristics demonstrated by the presented gas sensor are promising for acute exposure applications. PMID:28603384
Wan, Hao; Yin, Heyu; Mason, Andrew J
2017-04-01
Intense study on gas sensors has been conducted to implement fast gas sensing with high sensitivity, reliability and long lifetime. This paper presents a rapid amperometric method for gas sensing based on a room temperature ionic liquid electrochemical gas sensor. To implement a miniaturized sensor with a fast response time, a three electrode system with gold interdigitated electrodes was fabricated by photolithography on a porous polytetrafluoroethylene substrate that greatly enhances gas diffusion. Furthermore, based on the reversible reaction of oxygen, a new transient double potential amperometry (DPA) was explored for electrochemical analysis to decrease the measurement time and reverse reaction by-products that could cause current drift. Parameters in transient DPA including oxidation potential, oxidation period, reduction period and sample point were investigated to study their influence on the performance of the sensor. Oxygen measurement could be accomplished in 4 s, and the sensor presented a sensitivity of 0.2863 μA/[%O 2 ] and a linearity of 0.9943 when tested in air samples with different oxygen concentrations. Repeatability and long-term stability were also investigated, and the sensor was shown to exhibit good reliability. In comparison to conventional constant potential amperometry, transient DPA was shown to reduce relative standard deviation by 63.2%. With transient DPA, the sensitivity, linearity, repeatability, measurement time and current drift characteristics demonstrated by the presented gas sensor are promising for acute exposure applications.
Sun, Duanping; Lu, Jing; Chen, Zuanguang; Yu, Yanyan; Mo, Manni
2015-07-23
In this work, a repeatable assembling and disassembling electrochemical aptamer cytosensor was proposed for the sensitive detection of human liver hepatocellular carcinoma cells (HepG2) based on a dual recognition and signal amplification strategy. A high-affinity thiolated TLS11a aptamer, covalently attached to a gold electrode through Au-thiol interactions, was adopted to recognize and capture the target HepG2 cells. Meanwhile, the G-quadruplex/hemin/aptamer and horseradish peroxidase (HRP) modified gold nanoparticles (G-quadruplex/hemin/aptamer-AuNPs-HRP) nanoprobe was designed. It could be used for electrochemical cytosensing with specific recognition and enzymatic signal amplification of HRP and G-quadruplex/hemin HRP-mimicking DNAzyme. With the nanoprobes as recognizing probes, the HepG2 cancer cells were captured to fabricate an aptamer-cell-nanoprobes sandwich-like superstructure on a gold electrode surface. The proposed electrochemical cytosensor delivered a wide detection range from 1×10(2) to 1×10(7) cells mL(-1) and high sensitivity with a low detection limit of 30 cells mL(-1). Furthermore, after the electrochemical detection, the activation potential of -0.9 to -1.7V was performed to break Au-thiol bond and regenerate a bare gold electrode surface, while maintaining the good characteristic of being used repeatedly. The changes of gold electrode behavior after assembling and desorption processes were investigated by electrochemical impedance spectroscopy and cyclic voltammetry techniques. These results indicate that the cytosensor has great potential in disease diagnostic of cancers and opens new insight into the reusable gold electrode with repeatable assembling and disassembling in the electrochemical sensing. Copyright © 2015 Elsevier B.V. All rights reserved.
Fabric strain sensor integrated with CNPECs for repeated large deformation
NASA Astrophysics Data System (ADS)
Yi, Weijing
Flexible and soft strain sensors that can be used in smart textiles for wearable applications are much desired. They should meet the requirements of low modulus, large working range and good fatigue resistance as well as good sensing performances. However, there were no commercial products available and the objective of the thesis is to investigate fabric strain sensors based on carbon nanoparticle (CNP) filled elastomer composites (CNPECs) for potential wearing applications. Conductive CNPECs were fabricated and investigated. The introduction of silicone oil (SO) significantly decreased modulus of the composites to less than 1 MPa without affecting their deformability and they showed good stability after heat treatment. With increase of CNP concentration, a percolation appeared in electrical resistivity and the composites can be divided into three ranges. I-V curves and impedance spectra together with electro-mechanical studies demonstrated a balance between sensitivity and working range for the composites with CNP concentrations in post percolation range, and were preferred for sensing applications only if the fatigue life was improved. Due to the good elasticity and failure resist property of knitted fabric under repeated extension, it was adopted as substrate to increase the fatigue life of the conductive composites. After optimization of processing parameters, the conductive fabric with CNP concentration of 9.0CNP showed linear I-V curves when voltage is in the range of -1 V/mm and 1 V/mm and negligible capacitive behavior when frequency below 103 Hz even with strain of 60%. It showed higher sensitivity due to the combination of nonlinear resistance-strain behavior of the CNPECs and non-even strain distribution of knitted fabric under extension. The fatigue life of the conductive fabric was greatly improved. Extended on the studies of CNPECs and the coated conductive fabrics, a fabric strain sensor was designed, fabricated and packaged. The Young's modulus of the packaged fabric strain sensor was less than 1 MPa; the strain gauge factor was 4.76 within the strain range of 0-40% and the hysteresis was 5.5%; the resistance relaxation was 5.56% with a constant strain of 40%; the fatigue life of the sensor was more than 100,000 cycles.
ERIC Educational Resources Information Center
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-01-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items.…
High precision optical fiber Fabry-Perot sensor for gas pressure detection
NASA Astrophysics Data System (ADS)
Mao, Yan; Tong, Xing-lin
2013-09-01
An optical fiber Fabry-Perot (F-P) sensor with quartz diaphragm for gas pressure testing was designed and fabricated. It consisted of single-mode fiber, hollow glass tube and quartz diaphragm. It uses the double peak demodulation to obtain the initialized cavity length. The variety of cavity length can be calcultated by the single peak demodulation after changing the gas pressure. The results show that the sensor is small in size, whose sensitivity is 19 pm/kPa in the range of the 10 ~ 260 kPa gas pressure. And it has good linearity and repeatability.
ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin
Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus
2011-01-01
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed. PMID:25585565
ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin.
Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus
2011-10-27
In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed.
A Palladium-Tin Modified Microband Electrode Array for Nitrate Determination
Fu, Yexiang; Bian, Chao; Kuang, Jian; Wang, Jinfen; Tong, Jianhua; Xia, Shanhong
2015-01-01
A microband electrode array modified with palladium-tin bimetallic composite has been developed for nitrate determination. The microband electrode array was fabricated by Micro Electro-Mechanical System (MEMS) technique. Palladium and tin were electrodeposited successively on the electrode, forming a double-layer structure. The effect of the Pd-Sn composite was investigated and its enhancement of catalytic activity and lifetime was revealed. The Pd-Sn modified electrode showed good linearity (R2 = 0.998) from 1 mg/L to 20 mg/L for nitrate determination with a sensitivity of 398 μA/(mg∙L−1∙cm2). The electrode exhibited a satisfying analytical performance after 60 days of storage, indicating a long lifetime. Good repeatability was also displayed by the Pd-Sn modified electrodes. The results provided an option for nitrate determination in water. PMID:26389904
Enhanced capture rate for haze defects in production wafer inspection
NASA Astrophysics Data System (ADS)
Auerbach, Ditza; Shulman, Adi; Rozentsvige, Moshe
2010-03-01
Photomask degradation via haze defect formation is an increasing troublesome yield problem in the semiconductor fab. Wafer inspection is often utilized to detect haze defects due to the fact that it can be a bi-product of process control wafer inspection; furthermore, the detection of the haze on the wafer is effectively enhanced due to the multitude of distinct fields being scanned. In this paper, we demonstrate a novel application for enhancing the wafer inspection tool's sensitivity to haze defects even further. In particular, we present results of bright field wafer inspection using the on several photo layers suffering from haze defects. One way in which the enhanced sensitivity can be achieved in inspection tools is by using a double scan of the wafer: one regular scan with the normal recipe and another high sensitivity scan from which only the repeater defects are extracted (the non-repeater defects consist largely of noise which is difficult to filter). Our solution essentially combines the double scan into a single high sensitivity scan whose processing is carried out along two parallel routes (see Fig. 1). Along one route, potential defects follow the standard recipe thresholds to produce a defect map at the nominal sensitivity. Along the alternate route, potential defects are used to extract only field repeater defects which are identified using an optimal repeater algorithm that eliminates "false repeaters". At the end of the scan, the two defect maps are merged into one with optical scan images available for all the merged defects. It is important to note, that there is no throughput hit; in addition, the repeater sensitivity is increased relative to a double scan, due to a novel runtime algorithm implementation whose memory requirements are minimized, thus enabling to search a much larger number of potential defects for repeaters. We evaluated the new application on photo wafers which consisted of both random and haze defects. The evaluation procedure involved scanning with three different recipe types: Standard Inspection: Nominal recipe with a low false alarm rate was used to scan the wafer and repeaters were extracted from the final defect map. Haze Monitoring Application: Recipe sensitivity was enhanced and run on a single field column from which on repeating defects were extracted. Enhanced Repeater Extractor: Defect processing included the two parallel routes: a nominal recipe for the random defects and the new high sensitive repeater extractor algorithm. The results showed that the new application (recipe #3) had the highest capture rate on haze defects and detected new repeater defects not found in the first two recipes. In addition, the recipe was much simpler to setup since repeaters are filtered separately from random defects. We expect that in the future, with the advent of mask-less lithography and EUV lithography, the monitoring of field and die repeating defects on the wafer will become a necessity for process control in the semiconductor fab.
Sun, Min; Feng, Juanjuan; Bu, Yanan; Luo, Chuannan
2015-08-21
A fiber-in-tube solid-phase microextraction (SPME) device was developed with copper wire and copper tube, which was served as both the substrate and sorbent with high physical strength and good flexibility. Its morphology and surface properties were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. It was coupled with high performance liquid chromatography (HPLC) equipment by replacing the sample loop of six-port injection valve, building the online SPME-HPLC system conveniently. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, extraction conditions including sampling rate, extraction time, organic content and desorption time were investigated and optimized. The copper fiber-in-tube exhibits excellent extraction efficiency toward PAHs, with enrichment factors from 268 to 2497. The established online SPME-HPLC method provides good linearity (0.05-100μgL(-1)) and low detection limits (0.001-0.01μgL(-1)) for PAHs. It has been used to determine PAHs in water samples, with recoveries in the range of 86.2-115%. Repeatability on the same extraction tube is in the range of 0.6-3.6%, and repeatability among three tubes is in the range of 5.6-20.1%. Compared with phthalates, anilines and phenols, the copper fiber-in-tube possesses good extraction selectivity for PAHs. The extraction mechanism is probably related to hydrophobic interaction and π-electron-metal interaction. Copyright © 2015 Elsevier B.V. All rights reserved.
Jin, Yulong; Huang, Yanyan; Liu, Guoquan; Zhao, Rui
2013-09-21
A novel quartz crystal microbalance (QCM) sensor for rapid, highly selective and sensitive detection of copper ions was developed. As a signal amplifier, gold nanoparticles (Au NPs) were self-assembled onto the surface of the sensor. A simple dip-and-dry method enabled the whole detection procedure to be accomplished within 20 min. High selectivity of the sensor towards copper ions is demonstrated by both individual and coexisting assays with interference ions. This gold nanoparticle mediated amplification allowed a detection limit down to 3.1 μM. Together with good repeatability and regeneration, the QCM sensor was also applied to the analysis of copper contamination in drinking water. This work provides a flexible method for fabricating QCM sensors for the analysis of important small molecules in environmental and biological samples.
Benoit, Gaëlle; Heinkélé, Christophe; Gourdon, Emmanuel
2013-12-01
This paper deals with a numerical procedure to identify the acoustical parameters of road pavement from surface impedance measurements. This procedure comprises three steps. First, a suitable equivalent fluid model for the acoustical properties porous media is chosen, the variation ranges for the model parameters are set, and a sensitivity analysis for this model is performed. Second, this model is used in the parameter inversion process, which is performed with simulated annealing in a selected frequency range. Third, the sensitivity analysis and inversion process are repeated to estimate each parameter in turn. This approach is tested on data obtained for porous bituminous concrete and using the Zwikker and Kosten equivalent fluid model. This work provides a good foundation for the development of non-destructive in situ methods for the acoustical characterization of road pavements.
Vinci, Giuliana; Antonelli, Marta L; Preti, Raffaella
2013-02-01
Liquid-liquid microextraction coupled to LC with fluorescence detection for the determination of Environmental Protection Agency's 16 priority pollutant polycyclic aromatic hydrocarbons in rainwater has been developed. The optimization of the extraction method has involved several parameters, including the comparison between an ultrasonic bath and a magnetic stirrer as extractant apparatus, the choice of the extractant solvent, and the optimization of the extraction time. Liquid-liquid microextraction gave good results in terms of recoveries (from 73.6 to 102.8% in rainwater) and repeatability, with a very simple procedure and low solvent consumption. The reported chromatographic method uses a Core-Shell technology column, with particle size <3 μm instead of classical 5-μm particles column. The resulting backpressure was below 300 bar, allowing the use of a conventional HPLC system rather than the more expensive ultrahigh performance LC (UHPLC). An average decrease of 59% in run time and 75% in eluent consumption has been obtained, compared to classical HPLC methods, keeping good separation, sensitivity, and repeatability. The proposed conditions were successfully applied to the determinations of polycyclic aromatic hydrocarbons in genuine rainwater samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Optical fiber pressure sensor based on fiber Bragg grating
NASA Astrophysics Data System (ADS)
Song, Dongcao
In oil field, it is important to measure the high pressure and temperature for down-hole oil exploration and well-logging, the available traditional electronic sensor is challenged due to the harsh, flammable environment. Recently, applications based on fiber Bragg grating (FBG) sensor in the oil industry have become a popular research because of its distinguishing advantages such as electrically passive operation, immunity to electromagnetic interference, high resolution, insensitivity to optical power fluctuation etc. This thesis is divided into two main sections. In the first section, the design of high pressure sensor based on FBG is described. Several sensing elements based on FBG for high pressure measurements have been proposed, for example bulk-modulus or free elastic modulus. But the structure of bulk-modulus and free elastic modulus is relatively complex and not easy to fabricate. In addition, the pressure sensitivity is not high and the repeatability of the structure has not been investigated. In this thesis, a novel host material of carbon fiber laminated composite (CFLC) for high pressure sensing is proposed. The mechanical characteristics including principal moduli in three directions and the shape repeatability are investigated. Because of it's Young's modulus in one direction and anisotropic characteristics, the pressure sensor made by CFLC has excellent sensitivity. This said structure can be used in very high pressure measurement due to carbon fiber composite's excellent shape repetition even under high pressure. The experimental results show high pressure sensitivity of 0.101nm/MPa and high pressure measurement up to 70MPa. A pressure sensor based on CFLC and FBG with temperature compensation has been designed. In the second section, the design of low pressure sensor based on FBG is demonstrated. Due to the trade off between measurement range and sensitivity, a sensor for lower pressure range needs more sensitivity. A novel material of carbon fiber ribbon-wound composite cylindrical shell is proposed. The mechanical characteristics are analyzed. Due to the smaller longitudinal Young's modulus of this novel material, the sensitivity is improved to 0.452nm/MPa and the measurement range can reach 8MPa. The experimental results indicated excellent repeatability of the material and a good linearity between Bragg wavelength shift and the applied pressure. The sensor has the potential to find many industrial low pressure applications.
Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu
2014-12-01
In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations <10%. The overall recoveries are in the range of 98-103% in chili powder and in the range of 87-100% in chili oil depending on the concentration of rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhang, Huixin; Hong, Yingping; Liang, Ting; Zhang, Hairui; Tan, Qiulin; Xue, Chenyang; Liu, Jun; Zhang, Wendong; Xiong, Jijun
2015-01-01
A wireless passive pressure measurement system for an 800 °C high-temperature environment is proposed and the impedance variation caused by the mutual coupling between a read antenna and a LC resonant sensor is analyzed. The system consists of a ceramic-based LC resonant sensor, a readout device for impedance phase interrogation, heat insulating material, and a composite temperature-pressure test platform. Performances of the pressure sensor are measured by the measurement system sufficiently, including pressure sensitivity at room temperature, zero drift from room temperature to 800 °C, and the pressure sensitivity under the 800 °C high temperature environment. The results show that the linearity of sensor is 0.93%, the repeatability is 6.6%, the hysteretic error is 1.67%, and the sensor sensitivity is 374 KHz/bar. The proposed measurement system, with high engineering value, demonstrates good pressure sensing performance in a high temperature environment. PMID:25690546
Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham
2016-10-01
The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Jung, H; Kim, M
2014-06-01
Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulatedmore » dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.« less
Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri
2016-05-01
A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
An Enzyme-Induced Novel Biosensor for the Sensitive Electrochemical Determination of Isoniazid
Chokkareddy, Rajasekhar; Bhajanthri, Natesh Kumar; Redhi, Gan G.
2017-01-01
In this present work, a glassy carbon electrode (GCE) was modified primarily with multiwalled carbon nanotubes (MWCNTs) and a composite of MWCNTs and titanium oxide nanoparticles (TiO2NPs). The enzyme horseradish peroxidase (HRP) was immobilized to enhance the sensing ability of GCE. The proposed biosensor was used for the sensitive determination of isoniazid (INZ) in various pharmaceutical samples. The electrochemical behaviour of the developed MWCNT-TiO2NPs-HRP-GCE biosensor was studied by using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetry (TGA) and transmission electron microscopy (TEM) techniques were used to characterize the developed sensor. Phosphate buffer solution (PBS) with pH 7 was used as supporting electrolyte in the present investigation. The cyclic voltammetric results revealed that the increment of anodic peak currents for the enzyme-induced sensor was almost 8-fold greater than that of a bare GCE. The DPV technique exhibited good limit of detection and limit of quantification values, viz., 0.0335 μM and 0.1118 μM, respectively. Moreover, the developed sensor showed long-lasting stability and repeatability without any interferents. This strongly indicates that the fabricated sensor shows outstanding electrochemical performance towards INZ, with excellent selectivity and sensitivity. The developed sensor was successfully applied to pharmaceutical samples and gave good percentages of recoveries. PMID:28587260
Eigenvalue and eigenvector sensitivity and approximate analysis for repeated eigenvalue problems
NASA Technical Reports Server (NTRS)
Hou, Gene J. W.; Kenny, Sean P.
1991-01-01
A set of computationally efficient equations for eigenvalue and eigenvector sensitivity analysis are derived, and a method for eigenvalue and eigenvector approximate analysis in the presence of repeated eigenvalues is presented. The method developed for approximate analysis involves a reparamaterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations of changes in both the eigenvalues and eigenvectors associated with the repeated eigenvalue problem. Examples are given to demonstrate the application of such equations for sensitivity and approximate analysis.
Padulo, Johnny; Attene, Giuseppe; Ardigò, Luca P; Bragazzi, Nicola L; Maffulli, Nicola; Zagatto, Alessandro M; Dello Iacono, Antonio
2017-07-01
To investigate the effects of fatigue induced by a repeated sprint ability (RSA) test on the neuromuscular responses of soccer players with a recent history of lower limb injuries (CH) and a matched control group in good fitness condition (GH). This was a case-control study. Nine CH and 9 GH. Allocation to CH or GH. Each player was assessed for blood lactate concentration and jumping performance [squat jump (SJ) and countermovement jump (CMJ)] before/after RSA. Post-RSA rate of perceived exertion (RPE) was obtained. Receiver operating characteristic analysis was performed to calculate RSA sensitivity and specificity in distinguishing between CH and GH. Intraclass correlation coefficient was used to assess reliability. No baseline differences were found for any variable. ΔSJ before/after RSA was -14 ± 2% and -5 ± 2% in CH and GH, respectively (P < 0.05). ΔCMJ before/after RSA was -15 ± 2% and -7 ± 2% in CH and GH, respectively (P < 0.05). ΔSJ-based and ΔCMJ-based (before/after RSA) area under curve (AUC) resulted in 0.90 ± 0.07 and 0.86 ± 0.09, respectively, with both AUCs differentiating between CH and GH with 77.78% sensitivity and 88.89% specificity. Pooled AUC resulted in 0.88 ± 0.06. Intraclass correlation coefficient was high (0.85/0.97). Repeated sprint ability is a simple, low-cost field test potentially able to assist in clinical decision making for return to sport.
CHARACTERISTICS OF THERMOLUMINESCENCE LiF:Mg,Cu,Ag NANOPHOSPHOR.
Yahyaabadi, A; Torkzadeh, F; Rezaei-Ochbelagh, D
2018-04-23
A nanophosphor of LiF:Mg,Cu,Ag was prepared by planetary ball milling for the first time in the laboratory. The size and shape of the nanophosphor were confirmed by XRD and SEM, which showed that it was cubic in shape and ~53 nm in size. The thermoluminescence (TL) characteristics of this nanophosphor were then investigated. It was found that the optimum annealing condition was 250°C for 10 min. The TL sensitivity of the prepared nanopowder was less than that of its micropowder counterpart and the TL glow curve structure exhibited several peaks. The LiF:Mg,Cu,Ag nanophosphor exhibited a linear response over a range of doses from 1 Gy to ~10 kGy. From this study, it appears that LiF:Mg,Cu,Ag nanophosphor is a good candidate for dosimetry because of its linearity over a range of doses, low tendency to fade, good repeatability and simple glow curve structure.
Microscopic or occult hematuria, when reflex testing is not good laboratory practice.
Froom, Paul; Barak, Mira
2010-01-01
Consensus opinion suggests that hematuria found by dipstick and not confirmed on microscopic examination (<2 erythrocytes per high power field) signifies a false-positive reagent strip test result. Standard practice is to repeat the dipstick test several days later and if still positive to confirm by microscopic examination. If discordant results are obtained, experts recommend reflex testing for urinary myoglobin and hemoglobin concentrations. The question is whether or not this approach represents good laboratory practice. These recommendations are not evidence based. We conclude that the reference range for red blood cells on the reagent strip should be increased to 25x10(6) cells/L for young men, and 50x10(6) cells/L for the rest of the adult population, ranges consistent with flow cytometry reports. Confirmation reflex testing using tests that have inferior sensitivity, precision and probably accuracy is not recommended.
NASA Astrophysics Data System (ADS)
Chiu, Jasper Z. S.; Tucker, Ian G.; McDowell, Arlene
2016-11-01
High sensitivity quantification of the putative cell-penetrating peptide di-arginine-histidine (RRH) associated with poly (ethyl-cyanoacrylate) (PECA) nanoparticles was achieved without analyte separation, using a novel application of isobaric-tagging and high matrix-assisted laser desorption/ionization coupled to time-of-flight (MALDI-TOF) mass spectrometry. Isobaric-tagging reaction equilibrium was reached after 5 min, with 90% or greater RRH peptide successfully isobaric-tagged after 60 min. The accuracy was greater than 90%, which indicates good reliability of using isobaric-tagged RRH as an internal standard for RRH quantification. The sample intra- and inter-spot coefficients of variations were less than 11%, which indicate good repeatability. The majority of RRH peptides in the nanoparticle formulation were physically associated with the nanoparticles (46.6%), whereas only a small fraction remained unassociated (13.7%). The unrecovered RRH peptide (~40%) was assumed to be covalently associated with PECA nanoparticles.
Highly sensitive detection of individual HEAT and ARM repeats with HHpred and COACH.
Kippert, Fred; Gerloff, Dietlind L
2009-09-24
HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains.
Highly Sensitive Detection of Individual HEAT and ARM Repeats with HHpred and COACH
Kippert, Fred; Gerloff, Dietlind L.
2009-01-01
Background HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Methodology and Principal Findings Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. Significance A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains. PMID:19777061
Le, Binh Huy; Seo, Young Jun
2018-01-25
We have developed a gold nanoparticle (AuNP)-based CTG repeat probing system displaying high quenching capability and combined it with isothermal amplification for the detection of miRNA 146a. This method of using a AuNP-based CTG repeat probing system with isothermal amplification allowed the highly sensitive (14 aM) and selective detection of miRNA 146a. A AuNP-based CTG repeat probing system having a hairpin structure and a dT F fluorophore exhibited highly efficient quenching because the CTG repeat-based stable hairpin structure imposed a close distance between the AuNP and the dT F residue. A small amount of miRNA 146a induced multiple copies of the CAG repeat sequence during rolling circle amplification; the AuNP-based CTG repeat probing system then bound to the complementary multiple-copy CAG repeat sequence, thereby inducing a structural change from a hairpin to a linear structure with amplified fluorescence. This AuNP-based CTG probing system combined with isothermal amplification could also discriminate target miRNA 146a from one- and two-base-mismatched miRNAs (ORN 1 and ORN 2, respectively). This simple AuNP-based CTG probing system, combined with isothermal amplification to induce a highly sensitive change in fluorescence, allows the detection of miRNA 146a with high sensitivity (14 aM) and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Lenoir, Magalie; Tang, Jeremy S.; Woods, Amina S.
2013-01-01
Repeated exposure to nicotine and other psychostimulant drugs produces persistent increases in their psychomotor and physiological effects (sensitization), a phenomenon related to the drugs' reinforcing properties and abuse potential. Here we examined the role of peripheral actions of nicotine in nicotine-induced sensitization of centrally mediated physiological parameters (brain, muscle, and skin temperatures), cortical and VTA EEG, neck EMG activity, and locomotion in freely moving rats. Repeated injections of intravenous nicotine (30 μg/kg) induced sensitization of the drug's effects on all these measures. In contrast, repeated injections of the peripherally acting analog of nicotine, nicotine pyrrolidine methiodide (nicotinePM, 30 μg/kg, i.v.) resulted in habituation (tolerance) of the same physiological, neuronal, and behavioral measures. However, after repeated nicotine exposure, acute nicotinePM injections induced nicotine-like physiological responses: powerful cortical and VTA EEG desynchronization, EMG activation, a large brain temperature increase, but weaker hyperlocomotion. Additionally, both the acute locomotor response to nicotine and nicotine-induced locomotor sensitization were attenuated by blockade of peripheral nicotinic receptors by hexamethonium (3 mg/kg, i.v.). These data suggest that the peripheral actions of nicotine, which precede its direct central actions, serve as a conditioned interoceptive cue capable of eliciting nicotine-like physiological and neural responses after repeated nicotine exposure. Thus, by providing a neural signal to the CNS that is repeatedly paired with the direct central effects of nicotine, the drug's peripheral actions play a critical role in the development of nicotine-induced physiological, neural, and behavioral sensitization. PMID:23761889
Lenoir, Magalie; Tang, Jeremy S; Woods, Amina S; Kiyatkin, Eugene A
2013-06-12
Repeated exposure to nicotine and other psychostimulant drugs produces persistent increases in their psychomotor and physiological effects (sensitization), a phenomenon related to the drugs' reinforcing properties and abuse potential. Here we examined the role of peripheral actions of nicotine in nicotine-induced sensitization of centrally mediated physiological parameters (brain, muscle, and skin temperatures), cortical and VTA EEG, neck EMG activity, and locomotion in freely moving rats. Repeated injections of intravenous nicotine (30 μg/kg) induced sensitization of the drug's effects on all these measures. In contrast, repeated injections of the peripherally acting analog of nicotine, nicotine pyrrolidine methiodide (nicotine(PM), 30 μg/kg, i.v.) resulted in habituation (tolerance) of the same physiological, neuronal, and behavioral measures. However, after repeated nicotine exposure, acute nicotine(PM) injections induced nicotine-like physiological responses: powerful cortical and VTA EEG desynchronization, EMG activation, a large brain temperature increase, but weaker hyperlocomotion. Additionally, both the acute locomotor response to nicotine and nicotine-induced locomotor sensitization were attenuated by blockade of peripheral nicotinic receptors by hexamethonium (3 mg/kg, i.v.). These data suggest that the peripheral actions of nicotine, which precede its direct central actions, serve as a conditioned interoceptive cue capable of eliciting nicotine-like physiological and neural responses after repeated nicotine exposure. Thus, by providing a neural signal to the CNS that is repeatedly paired with the direct central effects of nicotine, the drug's peripheral actions play a critical role in the development of nicotine-induced physiological, neural, and behavioral sensitization.
Grappi, Silvia; Marchese, Giovanna; Secci, Maria Elena; De Montis, Maria Graziella; Gambarana, Carla; Scheggi, Simona
2011-10-01
Repeated unavoidable stress induces in rats decreased reactivity to avoidable stressors and an anhedonia-like condition that are reverted by long-term antidepressant treatments and regarded as models of core symptoms of depression. Morphine-sensitized rats present resilience to stress-induced behavioral deficits and, if hyporeactivity to stress models a depressive symptom, stress resistance can be regarded as a manic symptom. This hypothesis is supported by the observation that long-term lithium administration reinstates sensitivity to stress in sensitized rats. The first aim of the study was to examine the effects of carbamazepine, a standard antimanic treatment, on the stress resilience of sensitized rats, to further characterize morphine sensitization as a model of manic symptom. Carbamazepine administration abolished stress resilience but did not interfere with the expression of sensitization. The second aim of the study was to assess whether repeated carbamazepine treatment affected the dopaminergic and behavioral responses to a natural reward, a palatable food (vanilla sugar, VS), in non food-deprived sensitized and control rats and compare these possible effects with those of repeated lithium administration. Control and sensitized rats showed increased extraneuronal dopamine levels in the nucleus accumbens shell after VS consumption and competence to acquire an instrumental VS-sustained appetitive behavior (VAB). Repeated carbamazepine treatment abolished the dopaminergic response to VS consumption and disrupted the competence to acquire VAB in control rats. Lithium-treated rats showed a dopaminergic response to VS and easily acquired the appetitive behavior. In sensitized rats, neither carbamazepine nor lithium administration interfered with the dopaminergic response to VS and the acquisition of VAB. In summary, the effect of carbamazepine on the stress resilience of sensitized rats further supported the hypothesis that morphine sensitization might model some symptoms of mania. Moreover, in control rats carbamazepine treatment elicited an anhedonia-like condition that clearly distinguished the effects of this drug from those of lithium. Copyright © 2011 Elsevier Inc. All rights reserved.
Bu, Ri-E; Wang, Jin-Liang; Wu, Jin-Hua; Xilin, Gao-Wa; Chen, Jin-Long; Wang, Hua
2017-03-01
The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.
Mitry, Danny; Peto, Tunde; Hayat, Shabina; Morgan, James E; Khaw, Kay-Tee; Foster, Paul J
2013-01-01
Crowdsourcing is the process of outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing for the classification of retinal fundus photography. One hundred retinal fundus photograph images with pre-determined disease criteria were selected by experts from a large cohort study. After reading brief instructions and an example classification, we requested that knowledge workers (KWs) from a crowdsourcing platform classified each image as normal or abnormal with grades of severity. Each image was classified 20 times by different KWs. Four study designs were examined to assess the effect of varying incentive and KW experience in classification accuracy. All study designs were conducted twice to examine repeatability. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Without restriction on eligible participants, two thousand classifications of 100 images were received in under 24 hours at minimal cost. In trial 1 all study designs had an AUC (95%CI) of 0.701(0.680-0.721) or greater for classification of normal/abnormal. In trial 1, the highest AUC (95%CI) for normal/abnormal classification was 0.757 (0.738-0.776) for KWs with moderate experience. Comparable results were observed in trial 2. In trial 1, between 64-86% of any abnormal image was correctly classified by over half of all KWs. In trial 2, this ranged between 74-97%. Sensitivity was ≥ 96% for normal versus severely abnormal detections across all trials. Sensitivity for normal versus mildly abnormal varied between 61-79% across trials. With minimal training, crowdsourcing represents an accurate, rapid and cost-effective method of retinal image analysis which demonstrates good repeatability. Larger studies with more comprehensive participant training are needed to explore the utility of this compelling technique in large scale medical image analysis.
Subjective Sleep Quality Deteriorates Prior to Development of Painful Temporomandibular Disorder
Sanders, Anne E.; Akinkugbe, Aderonke A.; Bair, Eric; Fillingim, Roger B.; Greenspan, Joel D.; Ohrbach, Richard; Dubner, Ronald; Maixner, William; Slade, Gary D.
2016-01-01
There is good evidence that poor sleep quality increases risk of painful temporomandibular disorder (TMD). However little is known about the course of sleep quality in the months preceding TMD onset, and whether the relationship is mediated by heightened sensitivity to pain. The Pittsburgh Sleep Quality Index was administered at enrollment into the OPPERA prospective cohort study. Thereafter the Sleep Quality Numeric Rating Scale was administered every three months to 2,453 participants. Sensitivity to experimental pressure pain and pinprick pain stimuli was measured at baseline and repeated during follow-up of incident TMD cases (n=220) and matched TMD-free controls (n=193). Subjective sleep quality deteriorated progressively, but only in those who subsequently developed TMD. A Cox proportional hazards model showed that risk of TMD was greater among participants whose sleep quality worsened during follow-up (adjusted hazard ratio=1.73, 95% confidence limits: 1.29, 2.32). This association was independent of baseline measures of sleep quality, psychological stress, somatic awareness, comorbid conditions, non-pain facial symptoms and demographics. Poor baseline sleep quality was not significantly associated with baseline pain sensitivity or with subsequent change in pain sensitivity. Furthermore the relationship between sleep quality and TMD incidence was not mediated via baseline pain sensitivity nor change in pain sensitivity. PMID:26902644
Hintikka, Laura; Haapala, Markus; Kuuranne, Tiia; Leinonen, Antti; Kostiainen, Risto
2013-10-18
A gas chromatography-microchip atmospheric pressure photoionization-tandem mass spectrometry (GC-μAPPI-MS/MS) method was developed for the analysis of anabolic androgenic steroids in urine as their trimethylsilyl derivatives. The method utilizes a heated nebulizer microchip in atmospheric pressure photoionization mode (μAPPI) with chlorobenzene as dopant, which provides high ionization efficiency by producing abundant radical cations with minimal fragmentation. The performance of GC-μAPPI-MS/MS was evaluated with respect to repeatability, linearity, linear range, and limit of detection (LOD). The results confirmed the potential of the method for doping control analysis of anabolic steroids. Repeatability (RSD<10%), linearity (R(2)≥0.996) and sensitivity (LODs 0.05-0.1ng/mL) were acceptable. Quantitative performance of the method was tested and compared with that of conventional GC-electron ionization-MS, and the results were in good agreement. Copyright © 2013 Elsevier B.V. All rights reserved.
Temperature-independent fiber-Bragg-grating-based atmospheric pressure sensor
NASA Astrophysics Data System (ADS)
Zhang, Zhiguo; Shen, Chunyan; Li, Luming
2018-03-01
Atmospheric pressure is an important way to achieve a high degree of measurement for modern aircrafts, moreover, it is also an indispensable parameter in the meteorological telemetry system. With the development of society, people are increasingly concerned about the weather. Accurate and convenient atmospheric pressure parameters can provide strong support for meteorological analysis. However, electronic atmospheric pressure sensors currently in application suffer from several shortcomings. After an analysis and discussion, we propose an innovative structural design, in which a vacuum membrane box and a temperature-independent strain sensor based on an equal strength cantilever beam structure and fiber Bragg grating (FBG) sensors are used. We provide experimental verification of that the atmospheric pressure sensor device has the characteristics of a simple structure, lack of an external power supply, automatic temperature compensation, and high sensitivity. The sensor system has good sensitivity, which can be up to 100 nm/MPa, and repeatability. In addition, the device exhibits desired hysteresis.
NASA Astrophysics Data System (ADS)
Hu, Ruifen; Zhang, Kaihuan; Fan, Guokang; Luo, Zhiyuan; Li, Guang
2015-05-01
Nanostructured nickel hydroxide (nano-Ni(OH)2) was synthesized at a low temperature without annealing. Accordingly, a plasticizer sensor based on a quartz crystal microbalance (QCM) modified with the nano-Ni(OH)2 sensing film was fabricated to detect dibutyl phthalate (DBP) and its relative film thickness was optimized. The sensor worked at room temperature and exhibited a high sensitivity of 4.91 Hz ppb-1 to DBP in a low concentration range of 5-20 ppb, and an ultra-low detection limit of 5 ppb was achieved. In addition, the sensor maintained good repeatability as well as stability shown by the experimental data. The responses to five possible interferences and four other plasticizers were also measured, which indicated the excellent selectivity of the sensor and its potential use in monitoring plasticizers in a gaseous state.
Kawai, Takayuki; Watanabe, Masato; Sueyoshi, Kenji; Kitagawa, Fumihiko; Otsuka, Koji
2012-04-06
To obtain high sensitivity in capillary electrophoresis of oligosaccharide without reducing the high resolution with an easy experimental procedure, large-volume sample stacking with an electroosmotic flow pump (LVSEP) was investigated. As a fundamental study, effect of the conductivity of a sample solution in LVSEP was examined. It was revealed that LVSEP was successfully carried out even in using a sample solution with the ionic strength of 150 μM and the conductivity ratio of 20, indicating a good applicability of LVSEP to the analysis of real samples containing salts. When glucose oligomer was analyzed as a model sample in LVSEP-capillary zone electrophoresis (CZE), all peaks were well resolved with decreasing only 5% of the peak-to-peak distance, which suggested 95% of the whole capillary could be used for the effective separation. In the analysis of maltoheptaose, a good calibration line with correlation coefficient of 0.9995 was obtained. The limit of detection was estimated as 2 pM, which was 500-fold lower than that in the conventional CZE. N-linked glycans released from three glycoproteins, bovine ribonuclease B, bovine fetuin, and human α(1)-acid glycoprotein were also analyzed by LVSEP-CZE. By the sample purification with a gel filtration column, further sample dilution to reduce the sample conductivity for LVSEP was not needed. All glycan samples were well concentrated and separated with up to a 770-fold sensitivity increase. The run-to-run repeatabilities of the migration time, peak height, and peak area were good with relative standard deviations of 0.1-1.3%, 1.2-1.7%, and 2.8-4.9%, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.
Research on pressure tactile sensing technology based on fiber Bragg grating array
NASA Astrophysics Data System (ADS)
Song, Jinxue; Jiang, Qi; Huang, Yuanyang; Li, Yibin; Jia, Yuxi; Rong, Xuewen; Song, Rui; Liu, Hongbin
2015-09-01
A pressure tactile sensor based on the fiber Bragg grating (FBG) array is introduced in this paper, and the numerical simulation of its elastic body was implemented by finite element software (ANSYS). On the basis of simulation, fiber Bragg grating strings were implanted in flexible silicone to realize the sensor fabrication process, and a testing system was built. A series of calibration tests were done via the high precision universal press machine. The tactile sensor array perceived external pressure, which is demodulated by the fiber grating demodulation instrument, and three-dimension pictures were programmed to display visually the position and size. At the same time, a dynamic contact experiment of the sensor was conducted for simulating robot encountering other objects in the unknown environment. The experimental results show that the sensor has good linearity, repeatability, and has the good effect of dynamic response, and its pressure sensitivity was 0.03 nm/N. In addition, the sensor also has advantages of anti-electromagnetic interference, good flexibility, simple structure, low cost and so on, which is expected to be used in the wearable artificial skin in the future.
NASA Astrophysics Data System (ADS)
Ha, Nguyen Hai; Thinh, Dao Duc; Huong, Nguyen Thanh; Phuong, Nguyen Huy; Thach, Phan Duy; Hong, Hoang Si
2018-03-01
Zinc oxide (ZnO) nanoparticles loaded onto 3D reduced graphene oxide (3D-RGO) for carbon monoxide (CO) sensing were synthesized using hydrothermal method. The highly porous ZnO/3D-RGO configuration was stable without collapsing and was deposited on the micro-heater of the CO gas sensor. The resulting CO gas sensor displayed high sensitivity, fast response/recovery, and good linearity. The sensor achieved a response value of 85.2% for 1000 ppm CO at a working temperature of 200 °C. The response and recovery times of the sensor were 7 and 9 s for 1000 ppm CO at 200 °C. Similarly, the response value, response time, and recovery time of the sensor at room temperature were 27.5%, 14 s, and 15 s, respectively. The sensor demonstrated a distinct response to various CO concentrations in the range of 1-1000 ppm and good selectivity toward CO gas. In addition, the sensor exhibited good repeatability in multi-cycle and long-term stability.
Repeatability study of replicate crash tests: A signal analysis approach.
Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason
2017-10-03
To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.
Escobar, Angélica P; Cornejo, Francisca A; Olivares-Costa, Montserrat; González, Marcela; Fuentealba, José A; Gysling, Katia; España, Rodrigo A; Andrés, María E
2015-09-01
Dopamine from the ventral tegmental area and glutamate from several brain nuclei converge in the nucleus accumbens (NAc) to drive motivated behaviors. Repeated activation of D2 receptors with quinpirole (QNP) induces locomotor sensitization and compulsive behaviors, but the mechanisms are unknown. In this study, in vivo microdialysis and fast scan cyclic voltammetry in adult anesthetized rats were used to investigate the effect of repeated QNP on dopamine and glutamate neurotransmission within the NAc. Following eight injections of QNP, a significant decrease in phasic and tonic dopamine release was observed in rats that displayed locomotor sensitization. Either a systemic injection or the infusion of QNP into the NAc decreased dopamine release, and the extent of this effect was similar in QNP-sensitized and control rats, indicating that inhibitory D2 autoreceptor function is maintained despite repeated activation of D2 receptors and decreased dopamine extracellular levels. Basal extracellular levels of glutamate in the NAc were also significantly lower in QNP-treated rats than in controls. Moreover, the increase in NAc glutamate release induced by direct stimulation of medial prefrontal cortex was significantly lower in QNP-sensitized rats. Together, these results indicate that repeated activation of D2 receptors disconnects NAc from medial prefrontal cortex and ventral tegmental area. Repeated administration of the dopamine D2 receptor agonist quinpirole (QNP) induces locomotor sensitization. We found that the NAc of QNP-sensitized rats has reduced glutamate levels coming from prefrontal cortex together with a decreased phasic and tonic dopamine neurotransmission but a conserved presynaptic D2 receptor function. We suggest that locomotor sensitization is because of increased affinity state of D2 post-synaptic receptors. © 2015 International Society for Neurochemistry.
Mitry, Danny; Peto, Tunde; Hayat, Shabina; Blows, Peter; Morgan, James; Khaw, Kay-Tee; Foster, Paul J
2015-01-01
Crowdsourcing is the process of simplifying and outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing in the classification of normal and glaucomatous discs from optic disc images. Optic disc images (N = 127) with pre-determined disease status were selected by consensus agreement from grading experts from a large cohort study. After reading brief illustrative instructions, we requested that knowledge workers (KWs) from a crowdsourcing platform (Amazon MTurk) classified each image as normal or abnormal. Each image was classified 20 times by different KWs. Two study designs were examined to assess the effect of varying KW experience and both study designs were conducted twice for consistency. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Overall, 2,540 classifications were received in under 24 hours at minimal cost. The sensitivity ranged between 83-88% across both trials and study designs, however the specificity was poor, ranging between 35-43%. In trial 1, the highest AUC (95%CI) was 0.64(0.62-0.66) and in trial 2 it was 0.63(0.61-0.65). There were no significant differences between study design or trials conducted. Crowdsourcing represents a cost-effective method of image analysis which demonstrates good repeatability and a high sensitivity. Optimisation of variables such as reward schemes, mode of image presentation, expanded response options and incorporation of training modules should be examined to determine their effect on the accuracy and reliability of this technique in retinal image analysis.
NASA Astrophysics Data System (ADS)
La Vigna, Francesco; Hill, Mary C.; Rossetto, Rudy; Mazza, Roberto
2016-09-01
With respect to model parameterization and sensitivity analysis, this work uses a practical example to suggest that methods that start with simple models and use computationally frugal model analysis methods remain valuable in any toolbox of model development methods. In this work, groundwater model calibration starts with a simple parameterization that evolves into a moderately complex model. The model is developed for a water management study of the Tivoli-Guidonia basin (Rome, Italy) where surface mining has been conducted in conjunction with substantial dewatering. The approach to model development used in this work employs repeated analysis using sensitivity and inverse methods, including use of a new observation-stacked parameter importance graph. The methods are highly parallelizable and require few model runs, which make the repeated analyses and attendant insights possible. The success of a model development design can be measured by insights attained and demonstrated model accuracy relevant to predictions. Example insights were obtained: (1) A long-held belief that, except for a few distinct fractures, the travertine is homogeneous was found to be inadequate, and (2) The dewatering pumping rate is more critical to model accuracy than expected. The latter insight motivated additional data collection and improved pumpage estimates. Validation tests using three other recharge and pumpage conditions suggest good accuracy for the predictions considered. The model was used to evaluate management scenarios and showed that similar dewatering results could be achieved using 20 % less pumped water, but would require installing newly positioned wells and cooperation between mine owners.
Benedé, Juan L; Anderson, Jared L; Chisvert, Alberto
2018-01-01
In this work, a novel hybrid approach called stir bar dispersive liquid microextraction (SBDLME) that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) has been employed for the accurate and sensitive determination of ten polycyclic aromatic hydrocarbons (PAHs) in natural water samples. The extraction is carried out using a neodymium stir bar magnetically coated with a magnetic ionic liquid (MIL) as extraction device, in such a way that the MIL is dispersed into the solution at high stirring rates. Once the stirring is ceased, the MIL is magnetically retrieved onto the stir bar, and subsequently subjected to thermal desorption (TD) coupled to a gas chromatography-mass spectrometry (GC-MS) system. The main parameters involved in TD, as well as in the extraction step affecting the extraction efficiency (i.e., MIL amount, extraction time and ionic strength) were evaluated. Under the optimized conditions, the method was successfully validated showing good linearity, limits of detection and quantification in the low ng L -1 level, good intra- and inter-day repeatability (RSD < 13%) and good enrichment factors (18 - 717). This sensitive analytical method was applied to the determination of trace amounts of PAHs in three natural water samples (river, tap and rainwater) with satisfactory relative recovery values (84-115%), highlighting that the matrices under consideration do not affect the extraction process. Copyright © 2017 Elsevier B.V. All rights reserved.
HCPCF-based in-line fiber Fabry-Perot refractometer and high sensitivity signal processing method
NASA Astrophysics Data System (ADS)
Liu, Xiaohui; Jiang, Mingshun; Sui, Qingmei; Geng, Xiangyi; Song, Furong
2017-12-01
An in-line fiber Fabry-Perot interferometer (FPI) based on the hollow-core photonic crystal fiber (HCPCF) for refractive index (RI) measurement is proposed in this paper. The FPI is formed by splicing both ends of a short section of the HCPCF to single mode fibers (SMFs) and cleaving the SMF pigtail to a proper length. The RI response of the sensor is analyzed theoretically and demonstrated experimentally. The results show that the FPI sensor has linear response to external RI and good repeatability. The sensitivity calculated from the maximum fringe contrast is -136 dB/RIU. A new spectrum differential integration (SDI) method for signal processing is also presented in this study. In this method, the RI is obtained from the integrated intensity of the absolute difference between the interference spectrum and its smoothed spectrum. The results show that the sensitivity obtained from the integrated intensity is about -1.34×105 dB/RIU. Compared with the maximum fringe contrast method, the new SDI method can provide the higher sensitivity, better linearity, improved reliability, and accuracy, and it's also convenient for automatic and fast signal processing in real-time monitoring of RI.
Non-radioactive detection of trinucleotide repeat size variability.
Tomé, Stéphanie; Nicole, Annie; Gomes-Pereira, Mario; Gourdon, Genevieve
2014-03-06
Many human diseases are associated with the abnormal expansion of unstable trinucleotide repeat sequences. The mechanisms of trinucleotide repeat size mutation have not been fully dissected, and their understanding must be grounded on the detailed analysis of repeat size distributions in human tissues and animal models. Small-pool PCR (SP-PCR) is a robust, highly sensitive and efficient PCR-based approach to assess the levels of repeat size variation, providing both quantitative and qualitative data. The method relies on the amplification of a very low number of DNA molecules, through sucessive dilution of a stock genomic DNA solution. Radioactive Southern blot hybridization is sensitive enough to detect SP-PCR products derived from single template molecules, separated by agarose gel electrophoresis and transferred onto DNA membranes. We describe a variation of the detection method that uses digoxigenin-labelled locked nucleic acid probes. This protocol keeps the sensitivity of the original method, while eliminating the health risks associated with the manipulation of radiolabelled probes, and the burden associated with their regulation, manipulation and waste disposal.
Nakato, Yasuya; Abekawa, Tomohiro; Inoue, Takeshi; Ito, Koki; Koyama, Tsukasa
2011-10-24
We recently proposed a new psychostimulant animal model of the progressive pathophysiological changes of schizophrenia. Studies using that model produced a treatment strategy for preventing progression. Lamotrigine (LTG) blocks repeated high-dosage methamphetamine (METH)-induced initiation and expression of prepulse inhibition deficit and development of apoptosis in the medial prefrontal cortex (mPFC). Moreover, it inhibits METH-induced increases in extracellular glutamate levels in the mPFC (Nakato et al., 2011, Neurosci. Lett.). Abnormal behavior induced by METH or NMDA receptor antagonists is regarded as an animal model of schizophrenia. This study examined the effects of LTG on the development of behavioral sensitization to METH and cross-sensitization to dizocilpine (MK-801) by repeated administration of high-dose METH (2.5mg/kg, 10 times s.c.). Rats were injected repeatedly with LTG (30mg/kg) after 120min METH administration (2.5mg/kg). Repeated co-administration of LTG blocked the development of behavioral cross-sensitization to MK-801 (0.15mg/kg), but it did not prevent behavioral sensitization to METH (0.2mg/kg). The LTG-induced prevention of increased glutamate by high-dose METH might be related to the former finding. Combined results of our previous studies and this study suggest that LTG is useful to treat schizophrenia, especially at a critical point in its progression. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Humidity Sensor Based on PEDOT:PSS and Zinc Stannate Nano-composite
NASA Astrophysics Data System (ADS)
Aziz, Shahid; Chang, Dong Eui; Doh, Yang Hoi; Kang, Chul Ung; Choi, Kyung Hyun
2015-10-01
A composite of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) and zinc stannate (ZnSnO3) has been introduced for impedance-based humidity sensing, owing to its high sensitivity, good stability, very fast response (˜0.2 s) and recovery time (˜0.2 s), small hysteresis, repeatability, low-cost fabrication and wide range of sensitivity. Both materials were mixed in three different weight percentage ratios, to optimize the performance of the sensors. Best response was observed for 5 wt.% PEDOT:PSS and 5 wt.% ZnSnO3. The impedance of the sensor was dropped immensely from 1.5 MΩ to 50 kΩ by changing relative humidity from 0% to 90%. The reason for this improvement in sensitivity was analyzed by virtue of sensing mechanisms and different characterizations (three dimensional (3D) nano-profiler, optical microscope, and fourier transform infra-red (FTIR) spectroscopy) revealing the surface morphology and chemical structure of the film. Due to its response and ability to sense human breath and skin humidity, it is suitable for environmental, artificial skin and food industry applications.
Seguí, María del Mar; Cabrero-García, Julio; Crespo, Ana; Verdú, José; Ronda, Elena
2015-06-01
To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ). The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839). The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research. Copyright © 2015 Elsevier Inc. All rights reserved.
Bianchi, F; Careri, M; Maffini, M; Mangia, A; Mucchino, C
2003-01-01
A sensitive method for the simultaneous determination of (7)Li, (27)Al and (56)Fe by cold plasma ICP-MS was developed and validated. Experimental design was used to investigate the effects of torch position, torch power, lens 2 voltage, and coolant flow. Regression models and desirability functions were applied to find the experimental conditions providing the highest global sensitivity in a multi-elemental analysis. Validation was performed in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LODs were 1.4 and 159 ng L(-1) for (7)Li and (56)Fe, respectively; the highest LOD found being that for (27)Al (425 ng L(-1)). Linear ranges of 5 orders of magnitude for Li and 3 orders for Fe were statistically verified for each compound. Precision was evaluated by testing two concentration levels, and good results in terms of both intra-day repeatability and intermediate precision were obtained. RSD values lower than 4.8% at the lowest concentration level were calculated for intra-day repeatability. Commercially available soft drinks and alcoholic beverages contained in different packaging materials (TetraPack, polyethylene terephthalate (PET), commercial cans and glass) were analysed, and all the analytes were detected and quantitated. Copyright 2002 John Wiley & Sons, Ltd.
Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats
McGuire, Blaine A.; Baladi, Michelle G.; France, Charles P.
2011-01-01
Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1–10 mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. PMID:21371470
Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats.
McGuire, Blaine A; Baladi, Michelle G; France, Charles P
2011-05-11
Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1-10mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. Copyright © 2011 Elsevier B.V. All rights reserved.
Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan
2018-03-01
In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.
Detection of Organophosphorus Pesticides with Colorimetry and Computer Image Analysis.
Li, Yanjie; Hou, Changjun; Lei, Jincan; Deng, Bo; Huang, Jing; Yang, Mei
2016-01-01
Organophosphorus pesticides (OPs) represent a very important class of pesticides that are widely used in agriculture because of their relatively high-performance and moderate environmental persistence, hence the sensitive and specific detection of OPs is highly significant. Based on the inhibitory effect of acetylcholinesterase (AChE) induced by inhibitors, including OPs and carbamates, a colorimetric analysis was used for detection of OPs with computer image analysis of color density in CMYK (cyan, magenta, yellow and black) color space and non-linear modeling. The results showed that there was a gradually weakened trend of yellow intensity with the increase of the concentration of dichlorvos. The quantitative analysis of dichlorvos was achieved by Artificial Neural Network (ANN) modeling, and the results showed that the established model had a good predictive ability between training sets and predictive sets. Real cabbage samples containing dichlorvos were detected by colorimetry and gas chromatography (GC), respectively. The results showed that there was no significant difference between colorimetry and GC (P > 0.05). The experiments of accuracy, precision and repeatability revealed good performance for detection of OPs. AChE can also be inhibited by carbamates, and therefore this method has potential applications in real samples for OPs and carbamates because of high selectivity and sensitivity.
Purcell, Maureen K.; Powers, Rachel L.; Besijn, Bonnie; Hershberger, Paul K.
2017-01-01
We report the development and validation of two quantitative PCR (qPCR) assays to detect Nanophyetus salmincola DNA in water samples and in fish and snail tissues. Analytical and diagnostic validation demonstrated good sensitivity, specificity, and repeatability of both qPCR assays. The N. salmincola DNA copy number in kidney tissue was significantly correlated with metacercaria counts based on microscopy. Extraction methods were optimized for the sensitive qPCR detection of N. salmincola DNA in settled water samples. Artificially spiked samples suggested that the 1-cercaria/L threshold corresponded to an estimated log10 copies per liter ≥ 6.0. Significant correlation of DNA copy number per liter and microscopic counts indicated that the estimated qPCR copy number was a good predictor of the number of waterborne cercariae. However, the detection of real-world samples below the estimated 1-cercaria/L threshold suggests that the assays may also detect other N. salmincola life stages, nonintact cercariae, or free DNA that settles with the debris. In summary, the qPCR assays reported here are suitable for identifying and quantifying all life stages of N. salmincola that occur in fish tissues, snail tissues, and water.
Huang, Ke-Jing; Li, Jing; Liu, Yan-Ming; Wang, Lan
2013-02-01
The graphene functionalized with (3-aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1-100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029-0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Otis, Colombe; Gervais, Julie; Guillot, Martin; Gervais, Julie-Anne; Gauvin, Dominique; Péthel, Catherine; Authier, Simon; Dansereau, Marc-André; Sarret, Philippe; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Beaudry, Francis; Troncy, Eric
2016-06-23
Lack of validity in osteoarthritis pain models and assessment methods is suspected. Our goal was to 1) assess the repeatability and reproducibility of measurement and the influence of environment, and acclimatization, to different pain assessment outcomes in normal rats, and 2) test the concurrent validity of the most reliable methods in relation to the expression of different spinal neuropeptides in a chemical model of osteoarthritic pain. Repeatability and inter-rater reliability of reflexive nociceptive mechanical thresholds, spontaneous static weight-bearing, treadmill, rotarod, and operant place escape/avoidance paradigm (PEAP) were assessed by the intraclass correlation coefficient (ICC). The most reliable acclimatization protocol was determined by comparing coefficients of variation. In a pilot comparative study, the sensitivity and responsiveness to treatment of the most reliable methods were tested in the monosodium iodoacetate (MIA) model over 21 days. Two MIA (2 mg) groups (including one lidocaine treatment group) and one sham group (0.9 % saline) received an intra-articular (50 μL) injection. No effect of environment (observer, inverted circadian cycle, or exercise) was observed; all tested methods except mechanical sensitivity (ICC <0.3), offered good repeatability (ICC ≥0.7). The most reliable acclimatization protocol included five assessments over two weeks. MIA-related osteoarthritic change in pain was demonstrated with static weight-bearing, punctate tactile allodynia evaluation, treadmill exercise and operant PEAP, the latter being the most responsive to analgesic intra-articular lidocaine. Substance P and calcitonin gene-related peptide were higher in MIA groups compared to naive (adjusted P (adj-P) = 0.016) or sham-treated (adj-P = 0.029) rats. Repeated post-MIA lidocaine injection resulted in 34 times lower downregulation for spinal substance P compared to MIA alone (adj-P = 0.029), with a concomitant increase of 17 % in time spent on the PEAP dark side (indicative of increased comfort). This study of normal rats and rats with pain established the most reliable and sensitive pain assessment methods and an optimized acclimatization protocol. Operant PEAP testing was more responsive to lidocaine analgesia than other tests used, while neuropeptide spinal concentration is an objective quantification method attractive to support and validate different centralized pain functional assessment methods.
Chen, Xiao; Geng, Ling; Li, Hong
2014-04-01
To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.
Repeated Prescribed Burning in Aspen
Donald A. Perala
1974-01-01
Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.
Robinson, Mike J F; Anselme, Patrick; Suchomel, Kristen; Berridge, Kent C
2015-08-01
Amphetamine and stress can sensitize mesolimbic dopamine-related systems. In Pavlovian autoshaping, repeated exposure to uncertainty of reward prediction can enhance motivated sign-tracking or attraction to a discrete reward-predicting cue (lever-conditioned stimulus; CS+), as well as produce cross-sensitization to amphetamine. However, it remains unknown how amphetamine sensitization or repeated restraint stress interact with uncertainty in controlling CS+ incentive salience attribution reflected in sign-tracking. Here rats were tested in 3 successive phases. First, different groups underwent either induction of amphetamine sensitization or repeated restraint stress, or else were not sensitized or stressed as control groups (either saline injections only, or no stress or injection at all). All next received Pavlovian autoshaping training under either certainty conditions (100% CS-UCS association) or uncertainty conditions (50% CS-UCS association and uncertain reward magnitude). During training, rats were assessed for sign-tracking to the CS+ lever versus goal-tracking to the sucrose dish. Finally, all groups were tested for psychomotor sensitization of locomotion revealed by an amphetamine challenge. Our results confirm that reward uncertainty enhanced sign-tracking attraction toward the predictive CS+ lever, at the expense of goal-tracking. We also reported that amphetamine sensitization promoted sign-tracking even in rats trained under CS-UCS certainty conditions, raising them to sign-tracking levels equivalent to the uncertainty group. Combining amphetamine sensitization and uncertainty conditions did not add together to elevate sign-tracking further above the relatively high levels induced by either manipulation alone. In contrast, repeated restraint stress enhanced subsequent amphetamine-elicited locomotion, but did not enhance CS+ attraction. (c) 2015 APA, all rights reserved).
Robinson, Mike J.F.; Anselme, Patrick; Suchomel, Kristen; Berridge, Kent C.
2015-01-01
Amphetamine and stress can sensitize mesolimbic dopamine-related systems. In Pavlovian autoshaping, repeated exposure to uncertainty of reward prediction can enhance motivated sign-tracking or attraction to a discrete reward-predicting cue (lever CS+), as well as produce cross-sensitization to amphetamine. However, it remains unknown how amphetamine-sensitization or repeated restraint stress interact with uncertainty in controlling CS+ incentive salience attribution reflected in sign-tracking. Here rats were tested in three successive phases. First, different groups underwent either induction of amphetamine sensitization or repeated restraint stress, or else were not sensitized or stressed as control groups (either saline injections only, or no stress or injection at all). All next received Pavlovian autoshaping training under either certainty conditions (100% CS-UCS association) or uncertainty conditions (50% CS-UCS association and uncertain reward magnitude). During training, rats were assessed for sign-tracking to the lever CS+ versus goal-tracking to the sucrose dish. Finally, all groups were tested for psychomotor sensitization of locomotion revealed by an amphetamine challenge. Our results confirm that reward uncertainty enhanced sign-tracking attraction toward the predictive CS+ lever, at the expense of goal-tracking. We also report that amphetamine sensitization promoted sign-tracking even in rats trained under CS-UCS certainty conditions, raising them to sign-tracking levels equivalent to the uncertainty group. Combining amphetamine sensitization and uncertainty conditions together did not add together to elevate sign-tracking further above the relatively high levels induced by either manipulation alone. In contrast, repeated restraint stress enhanced subsequent amphetamine-elicited locomotion, but did not enhance CS+ attraction. PMID:26076340
Weinberg, Marc S.; Bhatt, Aadra P.; Girotti, Milena; Masini, Cher V.; Day, Heidi E. W.; Campeau, Serge; Spencer, Robert L.
2009-01-01
Repeated exposure to a moderately intense stressor typically produces attenuation of the hypothalamic-pituitary-adrenal (HPA) axis response (habituation) on re-presentation of the same stressor; however, if a novel stressor is presented to the same animals, the HPA axis response may be augmented (sensitization). The extent to which this adaptation is also evident within neural activity patterns is unknown. This study tested whether repeated ferret odor (FO) exposure, a moderately intense psychological stressor for rats, leads to both same-stressor habituation and novel-stressor sensitization of the HPA axis response and neuronal activity as determined by immediate early gene induction (c-fos mRNA). Rats were presented with FO in their home cages for 30 min a day for up to 2 wk and subsequently challenged with FO or restraint. Rats displayed HPA axis activity habituation and widespread habituation of c-fos mRNA expression (in situ hybridization) throughout the brain in as few as three repeated presentations of FO. However, repeated FO exposure led to a more gradual development of sensitized HPA-axis and c-fos mRNA responses to restraint that were not fully evident until after 14 d of prior FO exposure. The sensitized response was evident in many of the same brain regions that displayed habituation, including primary sensory cortices and the prefrontal cortex. The shared spatial expression but distinct temporal development of habituation and sensitization neural response patterns suggests two independent processes with opposing influences across overlapping brain systems. PMID:18845631
Thermoluminescent properties of some phosphor glasses based on aluminum oxide.
El Mesady, I; Khaled, N; Hussein, A; El Samman, H; Alawsh, S
2016-12-01
The transparent thermoluminescent aluminum oxide-based glass of 15Al 2 O 3 -35P 2 O 5 -25CaO-25Na 2 CO 3 , abbreviated as APCN (all in mol%) doped with different concentrations of SiO 2 from 0.0-500 ppm was prepared using a conventional melt-quenching technique. The TL sensitivities of the prepared glasses were investigated at 3 Gy γ-dose using a 60 Co source and measured at a heating rate 10 C/sec. The highest TL intensity of the material doped with SiO 2 was found at a concentration of 500 ppm (APCNSi 5 ). Deconvolution of the glow curve from APCNSi 5 resulted in four peaks at about 161, 194, 237 and 293 C with a Figure Of Merit (FOM) of 1.28%. The APCNSi 5 specimen had the best dosimetric properties when compared with the other samples. Reproducibility, repeatability, dose-response curve and fading effect were checked for peak 3, which appeared at about 237 C. The results displayed that the APCNSi 5 glass system was a low-Z material (Z eff ≈ 10), and had good reproducibility and good repeatability. Peak 3 showed good linearity over a dose range up to 20 Gy (R 2 = 0.999) and sublinearity behaviour was found. The signal from APCNSi 5 faded by about 11% after 2 days post irradiation, therefore it showed almost no significant loss. Such properties make the newly prepared glasses suitable for and highly recommended for use in γ-dosimeters. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Parker, Elizabeth S; Landau, Susan M; Whipple, Stephen C; Schwartz, Barbara L
2004-05-01
This study examines the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT) to the effects of aging in a sample of 112 men and women from 18 to 93 years old. Two new recognition measures, yes-no and forced-choice, were developed to supplement the original USC-REMT which measured only free-recall. Free-recall, yes-no recognition and forced-choice recognition were sensitive to age effects, with free-recall being the most sensitive. The seven recall and recognition lists can be used interchangeably. The data indicate that the USC-REMT is worthy of consideration when there is a need for a brief, screening tool of various memory functions, particularly when there is interest in memory changes over time and repeated assessments.
Luo, Qiaohui; Yu, Neng; Shi, Chunfei; Wang, Xiaoping; Wu, Jianmin
2016-12-01
A surface plasmon resonance (SPR) sensor combined with nanoscale molecularly imprinted polymer (MIP) film as recognition element was developed for selective detection of the antibiotic ciprofloxacin (CIP). The MIP film on SPR sensor chip was prepared by in situ photo-initiated polymerization method which has the advantages of short polymerization time, controllable thickness and good uniformity. The surface wettability and thickness of MIP film on SPR sensor chip were characterized by static contact angle measurement and stylus profiler. The MIP-SPR sensor exhibited high selectivity, sensitivity and good stability for ciprofloxacin. The imprinting factors of the MIP-SPR sensor to ciprofloxacin and its structural analogue ofloxacin were 2.63 and 3.80, which is much higher than those to azithromycin, dopamine and penicillin. The SPR response had good linear relation with CIP concentration over the range 10 -11 -10 -7 molL -1 . The MIP-SPR sensor also showed good repeatability and stability during cyclic detections. On the basis of the photo-initiated polymerization method, a surface plasmon resonance imaging (SPRi) chip modified with three types of MIP sensing spots was fabricated. The MIPs-SPRi sensor shows different response patterns to ciprofloxacin and azithromycin, revealing the ability to recognize different antibiotic molecules. Copyright © 2016 Elsevier B.V. All rights reserved.
Simultaneous measurement of temperature and strain based on composite long-period fiber grating
NASA Astrophysics Data System (ADS)
Tong, Chengguo; Hu, Qihao; He, Jiang; Chen, XuDong; Geng, Tao; Bao, Zhanjing; Li, Zixuan; Yang, Wenlei; Sun, Weimin
2016-11-01
Long period fiber grating is a kind of transmission type optical fiber grating. Due to the advantages such as low insertion loss, wide bandwidth, low-level reflection, high sensitivity, low cost and ease of compactness, LPFGs have been widely applied in optical fiber sensing and optical fiber communication. The Mode coupling of LPFG is the coupling between the fiber core mode and the cladding mode in the same transmission direction. If the ordinary LPFG is combined with bitaper or taper, we can effectively change the original LPFG's transmission spectrum to obtain the composite LPFG, which can stimulate new resonant peaks in the original wavelength-dependent transmission loss of the grating basis, thus applying to the dual-parameter simultaneously measuring field. We report a novel all-fiber narrow-bandwidth intermodal Mach- Zehnder interferometer (MZI) based on a long-period fiber grating (LPFG) combined with a fiber bitaper. The LPFG is written by high-frequency CO2 laser pulses, and the bitaper is connected in series with the LPFG, forming the Mach- Zehnder interferometer (MZI). Experimental results indicate that the MZI has good temperature sensitivity, The temperature sensitivity of the two loss peaks are 55.35pm/°C and 48.18pm/°C respectively. The strain sensitivity of the two loss peaks are 3.35pm/μɛ and -4.925pm/μɛ respectively. By using the different temperature and strain response characteristics of the loss peaks, the temperature and strain measurement can be realized simultaneously. the proposed device has good repeatability and stability, which would be a promising candidate for precise dual-parameter sensing application.
Fiber optic humidity sensor based on the graphene oxide/PVA composite film
NASA Astrophysics Data System (ADS)
Wang, Youqing; Shen, Changyu; Lou, Weimin; Shentu, Fengying
2016-08-01
Fiber optic humidity sensor based on an in-fiber Mach-Zehnder interferometer (MZI) coated with graphene oxide (GO)/PVA composite film was investigated. The MZI is constructed of two waist-enlarged tapers. The length between two waist-enlarged tapers is 20 mm. By comparing the experiment results of MZI coated with different GO/PVA composite films, composite film formed by the ratio of 0.3 g PVA mixed with 10 ml GO dispersion shows a better performance of relative humidity sensing. By using the molecular structure model of the composited GO/PVA, the operation mechanism between GO/PVA composite film and water molecules was illustrated. The sensitivity of 0.193 dB/%RH with a linear correlation coefficient of 99.1% and good stability under the relative humidity range of 25-80% was obtained. Temperature effect on the proposed fiber optic humidity sensor was also considered and analyzed. According to the repetitive experimental results, the proposed humidity sensor shows a good repeatability.
Lan, Jing; Liu, Chunfang; Gao, Mingxuan; Huang, Chengzhi
2015-11-01
In order to achieve the simple, easily repeated, and large scale preparation of fluorescent CDs, a new solid-state synthesis (SSS) approach was developed by calcining the mixture of fullerenes (C60) and solid sodium hydroxide. The cage of fullerenes could be opened and the hydroxyl and carboxyl were successfully introduced in the presence of sodium hydroxide under high temperature. The as-prepared surface carboxylated CDs possess many good properties, such as high water solubility, good photostability, salt tolerance, and nontoxicity. Especially, the fluorescence of CDs could be highly quenched by Fe(3+) because of the strong interaction of hydroxyl or carboxyl on the as-obtained CDs with Fe(3+), which realized a sensitive detection of Fe(3+) in the linear range of 0.02-0.6 μmol/L. What is more, we further applied the obtained CDs into the intracellular imaging of Fe(3+). Copyright © 2015 Elsevier B.V. All rights reserved.
Shu, Bin; Yang, Zhaoguang; Lee, Hsiaowan; Qiu, Bo; Li, Haipu
2016-02-01
An ultrasound-assisted emulsification microextraction based on the solidification of a floating organic droplet followed by gas chromatography with electron capture detection was developed for the simultaneous determination of 13 organochlorine pesticides in water samples. In the proposed method, ultrasound was applied to achieve the emulsification without addition of any dispersive solvent. In consequence, the volume of extraction phase remained unaffected by the ion strength of aqueous phase and high extraction recoveries were obtained. It was also found that dilution of the floating phase with acetone was necessary for preventing peak splitting in chromatogram. Under optimal conditions, the proposed method provided good sensitivity (the detection limits of organochlorine pesticides ranged from 1.3 to 3.9 ng/L) and good repeatability of extraction (below 6.5%, n = 5). The recoveries in reservoir and river water samples were between 75.8% and 96.9%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ultra-precise micro-motion stage for optical scanning test
NASA Astrophysics Data System (ADS)
Chen, Wen; Zhang, Jianhuan; Jiang, Nan
2009-05-01
This study aims at the application of optical sensing technology in a 2D flexible hinge test stage. Optical fiber sensor which is manufactured taking advantage of the various unique properties of optical fiber, such as good electric insulation properties, resistance of electromagnetic disturbance, sparkless property and availability in flammable and explosive environment, has lots of good properties, such as high accuracy and wide dynamic range, repeatable, etc. and is applied in 2D flexible hinge stage driven by PZT. Several micro-bending structures are designed utilizing the characteristics of the flexible hinge stage. And through experiments, the optimal micro-bending tooth structure and the scope of displacement sensor trip under this optimal micro-bending tooth structure are derived. These experiments demonstrate that the application of optical fiber displacement sensor in 2D flexible hinge stage driven by PZT substantially broadens the dynamic testing range and improves the sensitivity of this apparatus. Driving accuracy and positioning stability are enhanced as well. [1,2
NASA Technical Reports Server (NTRS)
Kenny, Sean P.; Hou, Gene J. W.
1994-01-01
A method for eigenvalue and eigenvector approximate analysis for the case of repeated eigenvalues with distinct first derivatives is presented. The approximate analysis method developed involves a reparameterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations to changes in the eigenvalues and the eigenvectors associated with the repeated eigenvalue problem. This work also presents a numerical technique that facilitates the definition of an eigenvector derivative for the case of repeated eigenvalues with repeated eigenvalue derivatives (of all orders). Examples are given which demonstrate the application of such equations for sensitivity and approximate analysis. Emphasis is placed on the application of sensitivity analysis to large-scale structural and controls-structures optimization problems.
Zandstra, Anna Roos E; Ormel, Johan; Hoekstra, Pieter J; Hartman, Catharina A
2018-01-01
The existing literature does not provide consistent evidence that carriers of the Dopamine D4 Receptor 7-repeat allele are more sensitive to adverse environmental influences, resulting in enhanced externalizing problems, compared to noncarriers. One explanation is that the adverse influences examined in prior studies were not severe, chronic, or distressing enough to reveal individual differences in sensitivity reflected by DRD4-7R. This study examined whether the 7-repeat allele moderated the association between chronic stressors capturing multiple stressful aspects of individuals' lives and externalizing problems in adolescence. We expected that chronic stressor levels would be associated with externalizing levels only in 7-repeat carriers. Using Linear Mixed Models, we analyzed data from 1621 Dutch adolescents (52.2% boys), obtained in three measurement waves (mean age approximately 11, 13.5, and 16 years) from the TRacking Adolescents' Individual Lives Survey (TRAILS) population-based birth cohort and the parallel clinic-referred cohort. Across informants, we found that higher levels of chronic stressors were related to higher externalizing levels in 7-repeat carriers but not in noncarriers, as hypothesized. Although previous studies on the 7-repeat allele as a moderator of environmental influences on adolescents' externalizing problems have not convincingly demonstrated individual differences in sensitivity to adverse environmental influences, our findings suggest that adolescent carriers of the Dopamine D4 Receptor 7-repeat allele are more sensitive to chronic, multi-context stressors than noncarriers.
A noncontact pneumatic esthesiometer for measurement of ocular sensitivity: a preliminary report.
Vega, J A; Simpson, T L; Fonn, D
1999-11-01
The aim of this investigation was to evaluate a prototype noncontact pneumatic esthesiometer for measuring sensitivity of the eye. To evaluate the instrument's repeatability, central corneal sensitivity was recorded on two separate occasions with a 24-h interval between the two measures. In a separate experiment, corneal edema was induced with a thick hydrogel lens, and the eye was closed and patched. Corneal sensitivity was measured before wearing the lenses for 3 h, immediately after lens removal, and 15 min later. Corneal sensitivity also was measured before the instillation of a single drop of proparacaine (Alcaine, 0.5%) and at 2 and 18 min later. Sensitivity was measured at the corneal apex and at a temporal conjunctival location 3 mm from the limbus. A high correlation was found between days 1 and 2 (r = 0.90; p = 0.0001). The coefficient of repeatability (COR = 0.87 mm Hg) showed that 95% of the difference between test and retest measures were between +/-0.87 mm Hg. Corneal sensitivity decreased by 55% after lens-induced corneal swelling and by 159% after instillation of the topical anesthetic. Central corneal sensitivity was found to be significantly higher than that of the temporal conjunctiva (p = 0.0001). We conclude that this pneumatic esthesiometer provides repeatable and reliable measures of ocular-surface sensitivity.
Wang, Chao; Li, Xue; Yu, Fei; Lu, Lu; Jiang, Xifeng; Xu, Xiaoyu; Wang, Huixin; Lai, Wenqing; Zhang, Tianhong; Zhang, Zhenqing; Ye, Ling; Jiang, Shibo; Liu, Keliang
2016-08-26
Peptides derived from the N-terminal heptad repeat (NHR) of HIV-1 gp41 can be potent inhibitors against viral entry when presented in a nonaggregating trimeric coiled-coil conformation via the introduction of exogenous trimerization motifs and intermolecular disulfide bonds. We recently discovered that crosslinking isopeptide bridges within the de novo helical trimers added exceptional resistance to unfolding. Herein, we attempted to optimize (CCIZN17)3, a representative disulfide bond-stabilized chimeric NHR-trimer, by incorporating site-specific interhelical isopeptide bonds as the redox-sensitive disulfide surrogate. In this process, we systematically examined the effect of isopeptide bond position and molecular sizes of auxiliary trimeric coiled-coil motif and NHR fragments on the antiviral potency of these NHR-trimers. Pleasingly, (IZ14N24N)3 possessed promising inhibitory activity against HIV-1 infection and markedly increased proteolytic stability relative to its disulfide-tethered counterpart, suggesting good potential for further development as an effective antiviral agent for treatment of HIV-1 infection.
Wang, Chao; Li, Xue; Yu, Fei; Lu, Lu; Jiang, Xifeng; Xu, Xiaoyu; Wang, Huixin; Lai, Wenqing; Zhang, Tianhong; Zhang, Zhenqing; Ye, Ling; Jiang, Shibo; Liu, Keliang
2016-01-01
Peptides derived from the N-terminal heptad repeat (NHR) of HIV-1 gp41 can be potent inhibitors against viral entry when presented in a nonaggregating trimeric coiled-coil conformation via the introduction of exogenous trimerization motifs and intermolecular disulfide bonds. We recently discovered that crosslinking isopeptide bridges within the de novo helical trimers added exceptional resistance to unfolding. Herein, we attempted to optimize (CCIZN17)3, a representative disulfide bond-stabilized chimeric NHR-trimer, by incorporating site-specific interhelical isopeptide bonds as the redox-sensitive disulfide surrogate. In this process, we systematically examined the effect of isopeptide bond position and molecular sizes of auxiliary trimeric coiled-coil motif and NHR fragments on the antiviral potency of these NHR-trimers. Pleasingly, (IZ14N24N)3 possessed promising inhibitory activity against HIV-1 infection and markedly increased proteolytic stability relative to its disulfide-tethered counterpart, suggesting good potential for further development as an effective antiviral agent for treatment of HIV-1 infection. PMID:27562370
Jones, Sherri Lee; Germé, Katuschia; Graham, M Dean; Roy, Patrick; Gardner Gregory, James; Rosenbaum, Stephanie; Parada, Mayte; Pfaus, James G
2015-09-01
The acute administration of estradiol benzoate (EB) to the ovariectomized (OVX) rat induces low levels of lordosis while sexually appetitive behaviors (e.g., hops, darts, solicitations) are absent, yet the repeated administration of EB results in a behavioral sensitization in which lordosis is potentiated and sexually appetitive behaviors are induced. We have shown that repeated copulation attenuates the sensitization of appetitive sexual behaviors. Here, we assessed which component of male stimulation during copulation is involved in the attenuation. On 8 occasions, sexually experienced OVX Long-Evans rats were treated with 10μgEB and 48h later assigned to one of six groups that differed in their experience on intermediates tests (2-7). One was given repeated access to a male (EB/Male), and another was placed in the copulation chamber alone (EB/Alone) on intermediate tests. Three groups were given one of three somatosensory stimuli by the experimenter: manual flank stimulation (FLS), clitoral stimulation (CLS), or vaginocervical stimulation (VCS). Finally, the control group was left undisturbed in the animal care facility (ACF). Sexual behaviors were measured on Tests 1 and 8. VCS received from the experimenter (VCS) or from the male during copulation (EB/Male) attenuated the magnitude of the sensitization of appetitive sexual behaviors compared with those that were not brought to the testing rooms (ACF), and the effect was most pronounced on sexual solicitations. These results suggest that VCS received during penile intromission inhibits the sensitization of sexually appetitive behaviors by repeated administration of EB. As such, repeated administration of EB may oppose those mechanisms that induce estrous termination, perhaps by sensitizing inhibitory processes within the ventromedial hypothalamus that typically prevent the display of sexual behaviors (i.e., by facilitating disinhibition). Copyright © 2015 Elsevier Inc. All rights reserved.
[Determination of 27 elements in Maca nationality's medicine by microwave digestion ICP-MS].
Yu, Gui-fang; Zhong, Hai-jie; Hu, Jun-hua; Wang, Jing; Huang, Wen-zhe; Wang, Zhen-zhong; Xiao, Wei
2015-12-01
An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.9994-1.0000 (Hg was 0.9982) ; the limits of detection were 0.003-2.662 microg x L(-1); the relative standard deviations for all elements of reproducibility were lower than 5% (except the individual elements); the recovery rate were 78.5%-123.7% with RSD lower than 5% ( except the individual elements). The analytical results of standard material showed acceptable agreement with the certified values. This method was applicable to determinate the contents of multi-elements in Maca which had a high sensitivity, good specificity and good repeatability, and provide basis for the quality control of Maca.
Development of QCM Trimethylamine Sensor Based on Water Soluble Polyaniline.
Li, Guang; Zheng, Junbao; Ma, Xingfa; Sun, Yu; Fu, Jun; Wu, Gang
2007-10-17
A rapid, sensitive, low-cost device to detect trimethylamine was presented in thispaper. The preparation of water soluble polyaniline was firstly studied. Then the polyanilinewas characterized via Fourier transform infrared spectroscopy (FTIR), UV-visiblespectroscopy and scanning electron microscopy (SEM). Based on the water solublepolyaniline film, a quartz crystal microbalance (QCM) sensor for trimethylamine detectionwas fabricated and its characteristics were examined. The sensor consisted of one quartzcrystal oscillator coated with the polyaniline film for sensing and the other one forreference. Pretreated with trimethylamine, the QCM sensor had an excellent linearsensitivity to trimethylamine. Easily recovered by N2 purgation, the response of the sensorexhibited a good repeatability. Responses of the sensor to trimethylamine, ethanol and ethylacetate were compared, and the results showed that the response was related to the polarityof the analyte vapor. Experimental result also showed that the sensitivity of the sensor wasrelatively stable within one month. The simple and feasible method to prepare and coat thepolyaniline sensing film makes it promising for mass production.
Detection of glycoprotein using fiber optic surface plasmon resonance sensors with boronic acid
NASA Astrophysics Data System (ADS)
Wang, Fang; Zhang, Yang; Liu, Zigeng; Qian, Siyu; Gu, Yiying; Jing, Zhenguo; Sun, Changsen; Peng, Wei
2017-04-01
In this paper, we present a tilted fiber Bragg gratings (TFBG) based surface Plasmon resonance (SPR) label-free sensors with boronic acid derivative (ABA-PBA) as receptor molecule to detect glycoprotein with high sensitivity and selectivity. Tilted fiber Bragg gratings (TFBG) as a near infrared wavelengths detecting element can be able to excite a number of cladding modes whose properties can be detected accurately by measuring the variation of transmitted spectra. A 10° TFBG coated by 50nm gold film was manufactured to stimulate surface plasmon resonance on the surface of the sensor. The sensor was loaded with boronic acid derivative as the recognition molecule which has been widely used in various areas for the recognition matrix of diol-containing biomolecules. The proposed TFBG-SPR sensors exhibit good selectivity and repeatability with the protein concentration sensitivity up to 2.867dB/ (mg/ml) and the limit of detection was 2*10-5g/ml.
Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor.
Hajian, A; Ghodsi, J; Afraz, A; Yurchenko, O; Urban, G
2016-12-01
This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH=7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13μmolL(-1) and detection limit of 25nmolL(-1). The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Suo, Hao; Sun, Baoshan
2017-11-15
Vidal Blanc grape (Vitis vinifera cv.) is the predominant white grape variety used for the production of icewine in China's Liaoning province. In this paper, the development and validation of the method by ultrahigh-performance liquid chromatography-tandem mass spectrometry has been performed for determination of the detailed phenolic composition in the skin, seed and stem of Vidal grapes. The validation of the method was realized by calculating the linearity, repeatability, precision, stability and the limits of detection (LOD) and quantification (LOQ) of standard solutions. All the curves exhibited good linearity (r 2 >0.9997) and the LOD and LOQ were in the range of 0.002-0.025 and 0.006-0.086μg/ml, respectively. Good repeatability (RSD<4.3%) and stability (RSD<3.7%) were also found. Results confirmed that the developed method was more effective and sensitive for simultaneous determination of the major phenolic compounds in Vidal grape pomace. The optimized and validated method of ultrahigh-performance liquid chromatography tandem two complementary techniques, fourier transform ion cyclotron resonance mass spectrometry and triple-quadrupole mass spectrometry, allowed to identify and quantify up to 35 phenolic compounds in Vidal grape pomace, which has, as far as we know, been reported this grapevine variety for the first time. Seeds, skins and stems exhibited different qualitative and quantitative phenolic profiles. These results provided useful information for recovery of phenolic antioxidants from different parts of icewine pomace. Copyright © 2017. Published by Elsevier B.V.
Double-pass Mach-Zehnder fiber interferometer pH sensor.
Tou, Zhi Qiang; Chan, Chi Chiu; Hong, Jesmond; Png, Shermaine; Eddie, Khay Ming Tan; Tan, Terence Aik Huang
2014-04-01
A biocompatible fiber-optic pH sensor based on a unique double-pass Mach-Zehnder interferometer is proposed. pH responsive poly(2-hydroxyethyl methacrylate-co-2-(dimethylamino)ethyl methacrylate) hydrogel coating on the fiber swells/deswells in response to local pH, leading to refractive index changes that manifest as shifting of interference dips in the optical spectrum. The pH sensor is tested in spiked phosphate buffer saline and demonstrates high sensitivity of 1.71 nm/pH, pH 0.004 limit of detection with good responsiveness, repeatability, and stability. The proposed sensor has been successfully applied in monitoring the media pH in cell culture experiments to investigate the relationship between pH and cancer cell growth.
Redruello, Begoña; Ladero, Victor; Cuesta, Isabel; Álvarez-Buylla, Jorge R; Martín, María Cruz; Fernández, María; Alvarez, Miguel A
2013-08-15
Derivatisation treatment with diethyl ethoxymethylenemalonate followed by ultra-HPLC allowed the simultaneous quantification of 22 amino acids, 7 biogenic amines and ammonium ions in cheese samples in under 10 min. This is the fastest elution time ever reported for such a resolution. The proposed method shows good linearity (R(2)>0.995) and sensitivity (detection limit 0.08-3.91 μM; quantification limit <13.02 μM). Intra- and inter-day repeatability ranged from 0.35% to 1.25% and from 0.85% to 5.2%, respectively. No significant effect of the cheese matrix was observed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fast BIA-amperometric determination of isoniazid in tablets.
Quintino, Maria S M; Angnes, Lúcio
2006-09-26
This paper proposes a new, fast and precise method to analyze isoniazid based on the electrochemical oxidation of the analyte at a glassy carbon electrode in 0.1M NaOH. The quantification was performed utilizing amperometry associated with batch injection analysis (BIA) technique. Fast sequential analysis (60 determinations h(-1)) in an unusually wide linear dynamic range (from 2.5 x 10(-8) to 1.0 x 10(-3)M), with high sensitivity and low limits of detection (4.1 x 10(-9)M) and quantification (1.4 x 10(-8)M), was achieved. Such characteristics allied to a good repeatability of the current responses (relative standard deviation of 0.79% for 30 measurements), were explored for the specific determination of isoniazid in isoniazid-rifampin tablet.
Dong, Bo; Zhou, Da-Peng; Wei, Li; Liu, Wing-Ki; Lit, John W Y
2008-11-10
A novel lateral force sensor based on a core-offset multi-mode fiber (MMF) interferometer is reported. High extinction ratio can be obtained by misaligning a fused cross section between the single-mode fiber (SMF) and MMF. With the variation of the lateral force applied to a short section of the MMF, the extinction ratio changes while the interference phase remains almost constant. The change of the extinction ratio is independent of temperature variations. The proposed force sensor has the advantages of temperature- and phase-independency, high extinction ratio sensitivity, good repeatability, low cost, and simple structure. Moreover, the core-offset MMF interferometer is expected to have applications in fiber filters and tunable phase-independent attenuators.
Bi, Liyan; Wang, Yunqing; Yang, Ying; Li, Yuling; Mo, Shanshan; Zheng, Qingyin; Chen, Lingxin
2018-05-09
Conventional research on surface-enhanced Raman scattering (SERS)-based pH sensors often depends on nanoparticle aggregation, whereas the variability in nanoparticle aggregation gives rise to poor repeatability in the SERS signal. Herein, we fabricated a gold nanorod array platform via an efficient evaporative self-assembly method. The platform exhibits great SERS sensitivity with an enhancement factor of 5.6 × 10 7 and maintains excellent recyclability and reproducibility with relative standard deviation (RSD) values of less than 8%. On the basis of the platform, we developed a highly sensitive bovine serum albumin (BSA)-coated 4-mercaptopyridine (4-MPy)-linked (BMP) SERS-based pH sensor to report pH ranging from pH 3.0 to pH 8.0. The intensity ratio variation of 1004 and 1096 cm -1 in 4-MPy showed excellent pH sensitivity, which decreased as the surrounding pH increased. Furthermore, this BMP SERS-based pH sensor was employed to measure the pH value in C57BL/6 mouse blood. We have demonstrated that the pH sensor has great advantages such as good stability, reliability, and accuracy, which could be extended for the design of point-of-care devices.
Zhang, Chen; Li, Ming
2012-02-01
Repeated administration of haloperidol (HAL) and olanzapine (OLZ) causes a progressively enhanced disruption of the conditioned avoidance response (CAR) and a progressively enhanced inhibition of phencyclidine (PCP)-induced hyperlocomotion in rats (termed antipsychotic sensitization). Both actions are thought to reflect intrinsic antipsychotic activity. The present study examined the extent to which antipsychotic-induced sensitization in one model (e.g. CAR) can be transferred or maintained in another (e.g. PCP hyperlocomotion) as a means of investigating the contextual and behavioral controls of antipsychotic sensitization. Well-trained male Sprague-Dawley rats were first repeatedly tested in the CAR or the PCP (3.2 mg/kg, subcutaneously) hyperlocomotion model under HAL or OLZ for 5 consecutive days. Then they were switched to the other model and tested for the expression of sensitization. Finally, all rats were switched back to the original model and retested for the expression of sensitization. Repeated HAL or OLZ treatment progressively disrupted avoidance responding and decreased PCP-induced hyperlocomotion, indicating a robust sensitization. When tested in a different model, rats previously treated with HAL or OLZ did not show a stronger inhibition of CAR-induced or PCP-induced hyperlocomotion than those treated with these drugs for the first time; however, they did show such an effect when tested in the original model in which they received repeated antipsychotic treatment. These findings suggest that the expression of antipsychotic sensitization is strongly influenced by the testing environment and/or selected behavioral response under certain experimental conditions. Distinct contextual cues and behavioral responses may develop an association with unconditional drug effects through a Pavlovian conditioning process. They may also serve as occasion setters to modulate the expression of sensitized responses. As antipsychotic sensitization mimics the clinical effects of antipsychotic treatment, understanding the neurobiological mechanisms of antipsychotic sensitization and its contextual control would greatly enhance our understanding of the psychological and neurochemical nature of antipsychotic treatment in the clinic.
Zhang, Chen; Li, Ming
2011-01-01
Repeated administration of haloperidol and olanzapine causes a progressively enhanced disruption of conditioned avoidance response (CAR) and a progressively enhanced inhibition of phencyclidine (PCP)-induced hyperlocomotion in rats (termed antipsychotic sensitization). Both actions are thought to reflect intrinsic antipsychotic activity. The present study examined to the extent to which antipsychotic-induced sensitization in one model (e.g. CAR) can be transferred or maintained in another (e.g. PCP hyperlocomotion) as a means of investigating the contextual and behavioral controls of antipsychotic sensitization. Well-trained male Sprague-Dawley rats were first repeatedly tested in the CAR or PCP (3.2 mg/kg, sc) hyperlocomotion model under haloperidol or olanzapine for five consecutive days. Then they were switched to the other model and tested for the expression of sensitization. Finally, all rats were switched back to the original model and retested for the expression of sensitization. Repeated haloperidol or olanzapine treatment progressively disrupted avoidance responding and decreased PCP-induced hyperlocomotion, indicating a robust sensitization. When tested in a different model, rats previously treated with haloperidol or olanzapine did not show a stronger inhibition of CAR or PCP-induced hyperlocomotion than those treated with these drugs for the first time; however, they did show such an effect when tested in the original model in which they received repeated antipsychotic treatment. These findings suggest that the expression of antipsychotic sensitization is strongly influenced by the testing environment and/or selected behavioral response under certain experimental conditions. Distinct contextual cues and behavioral responses may enter an association with unconditional drug effects via a Pavlovian conditioning process. They may also serve as occasion-setters to modulate the expression of sensitized responses. Because antipsychotic sensitization mimics clinical effects of antipsychotic treatment, understanding the neurobiological mechanisms of antipsychotic sensitization and its contextual control would greatly enhance our understanding of the psychological and neurochemical nature of antipsychotic treatment in the clinic. PMID:22157143
NASA Astrophysics Data System (ADS)
Yan, Xia; Shi, Xiaofeng; Yang, Jie; Zhang, Xu; Jia, Wenjie; Ma, Jun
2017-10-01
A self-assembled surface enhanced Raman scattering (SERS) sensor is reported in this paper. To achieve high sensitivity, a high sensitive SERS substrate and a high efficient self-constructed light path were made. The SERS substrate was composed by gold nanoparticles (AuNPs, pH=13), glycidyl methacrylate-ethylene dimethacrylate (GMA-EDMA) porous material and syringe filter. The substrate had a good repeatability, and the relative standard deviation (RSD) of the same substrate was less than 5%. The efficiency of the self-constructed light path is about two times better than RPB Y type reflection fiber when the energy density was roughly equal on samples. The size of the SERS sensor is 350×300×180 mm and the weight is 15 kg. Its miniaturization and portable can comply with the requirements of field detection. Besides, it has good sensitivity, stability and selectivity. For lab experiments, strong enhancements of Raman scattering from organic pollutant polycyclic aromatic hydrocarbons (PAHs) molecules were exhibited. The dependences of SERS intensities on concentrations of PAHs were investigated, and the results indicated that they revealed a satisfactory linear relationship in low concentrations. The limits of detection (LODs) of PAHs phenanthrene and fluorene are 8.3×10-10 mol/L and 7.1×10-10 mol/L respectively [signal to noise ratio (S/N) =3]. Based on this SERS sensor, signals of benzo (a) pyrene and pyrene were found in environmental water and the sensor would be an ideal candidate for field detection of PAHs.
Benedé, Juan L; Chisvert, Alberto; Giokas, Dimosthenis L; Salvador, Amparo
2016-01-15
In this work, a new approach that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE), i.e. stir bar sorptive-dispersive microextraction (SBSDµE), is employed as enrichment and clean-up technique for the sensitive determination of eight lipophilic UV filters in water samples. The extraction is accomplished using a neodymium stir bar magnetically coated with oleic acid-coated cobalt ferrite magnetic nanoparticles (MNPs) as sorbent material, which are detached and dispersed into the solution at high stirring rate. When stirring is stopped, MNPs are magnetically retrieved onto the stir bar, which is subjected to thermal desorption (TD) to release the analytes into the gas chromatography-mass spectrometry (GC-MS) system. The SBSDµE approach allows for lower extraction time than SBSE and easier post-extraction treatment than DSPE, while TD allows for an effective and solvent-free injection of the entire quantity of desorbed analytes into GC-MS, and thus achieving a high sensitivity. The main parameters involved in TD, as well as the extraction time, were evaluated. Under the optimized conditions, the method was successfully validated showing good linearity, limits of detection and quantification in the low ngL(-1) range and good intra- and inter-day repeatability (RSD<12%). This accurate and sensitive analytical method was applied to the determination of trace amounts of UV filters in three bathing water samples (river, sea and swimming pool) with satisfactory relative recovery values (80-116%). Copyright © 2015 Elsevier B.V. All rights reserved.
Vogel, Adam P; Fletcher, Janet; Snyder, Peter J; Fredrickson, Amy; Maruff, Paul
2011-03-01
Assessment of the voice for supporting classifications of central nervous system (CNS) impairment requires a different practical, methodological, and statistical framework compared with assessment of the voice to guide decisions about change in the CNS. In experimental terms, an understanding of the stability and sensitivity to change of an assessment protocol is required to guide decisions about CNS change. Five experiments (N = 70) were conducted using a set of commonly used stimuli (eg, sustained vowel, reading, extemporaneous speech) and easily acquired measures (eg, f₀-f₄, percent pause). Stability of these measures was examined through their repeated application in healthy adults over brief and intermediate retest intervals (ie, 30 seconds, 2 hours, and 1 week). Those measures found to be stable were then challenged using an experimental model that reliably changes voice acoustic properties (ie, the Lombard effect). Finally, adults with an established CNS-related motor speech disorder (dysarthria) were compared with healthy controls. Of the 61 acoustic variables studied, 36 showed good stability over all three stability experiments (eg, number of pauses, total speech time, speech rate, f₀-f₄. Of the measures with good stability, a number of frequency measures showed a change in response to increased vocal effort resulting from the Lombard effect challenge. Furthermore, several timing measures significantly separated the control and motor speech impairment groups. Measures with high levels of stability within healthy adults, and those that show sensitivity to change and impairment may prove effective for monitoring changes in CNS functioning. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Riday, Thorfinn T.; Kosofsky, Barry E.; Malanga, C.J.
2011-01-01
Repeated psychostimulant exposure progressively increases their potency to stimulate motor activity in rodents. This behavioral or locomotor sensitization is considered a model for some aspects of drug addiction in humans, particularly drug craving during abstinence. However, the role of increased motor behavior in drug reward remains incompletely understood. Intracranial self-stimulation (ICSS) was measured concurrently with locomotor activity to determine if acute intermittent cocaine administration had distinguishable effects on motor behavior and perception of brain stimulation-reward (BSR) in the same mice. Sensitization is associated with changes in neuronal activity and glutamatergic neurotransmission in brain reward circuitry. Expression of AMPA receptor subunits (GluR1 and GluR2) and CRE binding protein (CREB) was measured in the ventral tegmental area (VTA), dorsolateral striatum (STR) and nucleus accumbens (NAc) before and after a sensitizing regimen of cocaine, with and without ICSS. Repeated cocaine administration sensitized mice to its locomotor stimulating effects but not its ability to potentiate BSR. ICSS increased GluR1 in the VTA but not NAc or STR, demonstrating selective changes in protein expression with electrical stimulation of discrete brain structures. Repeated cocaine reduced GluR1, GluR2 and CREB expression in the NAc, and reductions of GluR1 and GluR2 but not CREB were further enhanced by ICSS. These data suggest that the effects of repeated cocaine exposure on reward and motor processes are dissociable in mice, and that reduction of excitatory neurotransmission in the NAc may predict altered motor function independently from changes in reward perception. PMID:22197517
Brenhouse, Heather C; Montalto, Stefanie; Stellar, James R
2006-06-30
Repeated exposure to cocaine leads to behavioral sensitization, which is the augmentation of the locomotor response to a subsequent exposure to the drug. The nucleus accumbens (NAc), a major termination site of dopaminergic neurons, is believed to be involved in behavioral sensitization and studies have demonstrated that the NAc shell can be split into five zones of analysis; the vertex, arch, cone, intermediate and ventrolateral zones [Todtenkopf MS, Stellar JR. Assessment of tyrosine hydroxylase immunoreactive innervation in five subregions of the nucleus accumbens shell in rats treated with repeated cocaine. Synapse 2000;38:261-70]. Several reports show cocaine-induced c-fos expression particularly in the intermediate zone after 14, but not 2, drug-free days following repeated cocaine administration, suggesting that this region may be involved in sensitization and particularly in the later phase of expression, versus the earlier phase of sensitization. Bilateral electrolytic lesions of the intermediate zone were made in two groups of rats, which were then repeatedly exposed to cocaine (15 mg/kg, twice/day for 5 days). One group was subsequently given a single cocaine challenge injection (15 mg/kg) after 14 drug-free days, while the other group was challenged after only 2 drug-free days. Two sham surgery groups in which an electrode was lowered but no current was passed served as controls. Results show that lesioned animals as well as sham controls exhibited behavioral sensitization to the drug. However, following a 14-day drug-free period, the lesioned animals showed significant reduction in sensitization, compared to sham controls. Together these findings suggest that the intermediate zone of the NAc shell is indeed involved in the expression phase of behavioral sensitization to cocaine.
Kim, Myoung-Hee; Cho, Young-Shin; Uhm, Wan-Sik; Kim, Sehyun; Bae, Sang-Cheol
2005-06-01
This study aimed to determine the cross-cultural adaptation and validation of the Korean version of the EQ-5D in rheumatic conditions. Translation, back-translation and cognitive debriefing were performed according to the EuroQol group's guidelines. For validity, 508 patients were recruited and administered the EQ-5D, Short-Form 36 and condition-specific measures. Construct validity and sensitivity were evaluated by testing a-priori hypotheses. For reliability, another 57 patients repeated the EQ-5D at 1-week interval, and intra-class correlations (ICC) and kappa statistics were estimated. For responsiveness, another 60 patients repeated it at 12-week interval within the context of clinical trial, and standardized response mean(SRM) were calculated. The cross-cultural adaptation produced no major modifications in the scale. The associations of the EQ-5D with the generic- and condition-specific measures were observed as expected in hypotheses: the higher EQ-5Dindex and EQ-5D(VAS) scores, the better health status by generic- or condition-specific measures, and the better functional class. The ICCs were 0.751 and 0.767, respectively, and kappa ranged from 0.455 to 0.772. The SRM were 0.649 and 0.410, respectively. The Korean EQ-5D exhibits good validity and sensitivity in various rheumatic conditions. Although its reliability and responsiveness were not excellent, it seems acceptable if condition-specific measures are applied together.
Period 3 gene polymorphism and sleep adaptation to stressful urban environments.
Anderson, Maxwell R; Akeeb, Ameenat; Lavela, Joseph; Chen, Yuanxiu; Mellman, Thomas A
2017-02-01
This study's objective was to investigate the relationship between a variable-number tandem-repeat (VNTR) Period 3 gene (PER3) polymorphism and sleep adaptation to stressful urban environments. Seventy-five (49 female) African American participants (ages 18-35 years) living in neighbourhoods with high rates of violent crime were selected for the study based on converging criteria for good or poor sleep. Categorization of sleep quality was based on the Insomnia Severity Index (ISI), estimates of typical sleep duration and sleep efficiency. Other assessments included the Fear of Sleep Index (FOSI) and City Stress Inventory (CSI). Whole blood DNA was analysed for the 4 and 5 VNTR alleles using polymerase chain reaction (PCR) and restrictive enzyme digestion. Fifty-seven per cent of those who were homo- or heterozygous for the 4-repeat allele were poor sleepers versus 25% of those homozygous for the 5-repeat allele; χ 2 = 4.17, P = 0.041. In a logistic regression model with all the variables with significant bivariate relationships to sleep quality group, FOSI was the only significant predictor (χ 2 = 5.68, P = 0.017). FOSI scores were higher among those with the 4-repeat allele (t = 2.66, P = 0.013). The PER3 4 and 5 VNTR polymorphisms appear to influence sensitivity to the effects of stressful urban environments on sleep. While FOSI was the only variable associated independently with sleep quality category, the candidate vulnerability allele was also associated with greater 'fear of sleep'. © 2016 European Sleep Research Society.
Galli, Alvaro; Cervelli, Tiziana; Schiestl, Robert H
2003-05-01
The DNA polymerase delta (Pol3p/Cdc2p) allele pol3-t of Saccharomyces cerevisiae has previously been shown to increase the frequency of deletions between short repeats (several base pairs), between homologous DNA sequences separated by long inverted repeats, and between distant short repeats, increasing the frequency of genomic deletions. We found that the pol3-t mutation increased intrachromosomal recombination events between direct DNA repeats up to 36-fold and interchromosomal recombination 14-fold. The hyperrecombination phenotype of pol3-t was partially dependent on the Rad52p function but much more so on Rad1p. However, in the double-mutant rad1 Delta rad52 Delta, the pol3-t mutation still increased spontaneous intrachromosomal recombination frequencies, suggesting that a Rad1p Rad52p-independent single-strand annealing pathway is involved. UV and gamma-rays were less potent inducers of recombination in the pol3-t mutant, indicating that Pol3p is partly involved in DNA-damage-induced recombination. In contrast, while UV- and gamma-ray-induced intrachromosomal recombination was almost completely abolished in the rad52 or the rad1 rad52 mutant, there was still good induction in those mutants in the pol3-t background, indicating channeling of lesions into the above-mentioned Rad1p Rad52p-independent pathway. Finally, a heterozygous pol3-t/POL3 mutant also showed an increased frequency of deletions and MMS sensitivity at the restrictive temperature, indicating that even a heterozygous polymerase delta mutation might increase the frequency of genetic instability.
NASA Astrophysics Data System (ADS)
Butler, Thomas M.; MacCraith, Brian D.; McDonagh, Colette M.
1995-09-01
The sol-gel process has been used to entrap pH indicators in porous glass coatings for sensor applications. This sensor is based on evanescent wave absorption using an unclad optical fiber dipcoated with the pH sensitive coating. The entrapped pH indicators show a broadening of the pH range with respect to the behavior in solution giving accurate measurement over three pH units when one indicator is used (bromophenol blue) and over six pH units (pH 3-9) when two indicators are used (bromophenol blue and bromocresol purple). The response of the pH sensor was monitored by measuring absorption at 590 nm referenced against a nonabsorbing region of the spectrum. This enabled the use of LED sources together with low cost photodiodes. The sensor displayed short response time and good repeatability. The thickness and stability of the pH sensitive coatings can be influenced by modifying the composition of the starting sol mixture. The evanescent absorption, and hence the sensitivity of the sensor, can be increased by selectively launching higher order modes in the fiber. These issues together with a full sensor characterization will be reported.
Ghaedi, Hamed; Afkhami, Abbas; Madrakian, Tayyebeh; Soltani-Felehgari, Farzaneh
2016-02-01
A new chemically modified carbon paste electrode (CMCPE) was applied to the simple, rapid, highly selective and sensitive determination of citalopram in human serum and pharmaceutical preparations using adsorptive square wave voltammetry (ASWV). The ZnO nanoparticles and multi-walled carbon nanotubes modified CPE (ZnO-MWCNT/CPE) electrode was prepared by incorporation of the ZnO nanoparticles and multi-walled carbon nanotubes (MWCNT) in carbon paste electrode. The limit of detection and the linear range were found to be 0.005 and 0.012 to 1.54μmolL(-1) of citalopram, respectively. The effects of potentially interfering substances on the determination of this compound were investigated and found that the electrode is highly selective. The proposed CMCPE was used to the determination of citalopram in human serum, urine and pharmaceutical samples. This reveals that ZnO-MWCNT/CPE shows excellent analytical performance for the determination of citalopram in terms of very low detection limit, high sensitivity, very good repeatability and reproducibility over other methods reported in the literature. Copyright © 2015. Published by Elsevier B.V.
Adaptive play stabilizes cooperation in continuous public goods games
NASA Astrophysics Data System (ADS)
Wu, Te; Wang, Long
2018-04-01
We construct a model to study the effects of repeated interaction on the evolution of cooperation in continuous public goods games. Instead of preassigning the duration of repeatedness, the likelihood of group entering next round interaction is positively dependent on the group's current cooperativeness. Meanwhile, when the disturbance happens, the interaction terminates. Under rare mutations, we show that such adaptive play can lead to the dominance of full cooperative state for weak disturbance. For fairly strong disturbance, all-or-none cooperative states share higher fractions of time in the long run, results similar to the ones reported in the study (Pinheiro et al., 2014) while differing from the ones reported in another relevant study (Van Segbroeck et al., 2012), although only strategy space and way determining next round vary. Our results remain valid when groups enter next round with a given probability independent of groups' cooperativeness. In the synergic public goods games, the positive effects of repeated interactions on promoting cooperation is further strengthened. In the discounted public goods game, only very weak disturbance can lead to the dominance of full cooperative state while fairly strong disturbance can favor both full cooperative state and a partially cooperative state. Our study thus enriches the literature on the evolution of cooperation in repeated public goods games.
Sun, Yanchun; Xu, Xianzhu; Mou, Zhenbo; Wang, Jing; Tan, Zhijun; Wu, Song
2012-12-01
A rapid, sensitive, and reliable ultra-performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6-aminoquinolyl-carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C(18) column with Acetonitrile-acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5-1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Does it really feel the same? Changes in life satisfaction following repeated life events.
Luhmann, Maike; Eid, Michael
2009-08-01
Unemployment, divorce, and marriage are common life events for most people in Western societies. In a longitudinal study, the authors investigated how these life events affect life satisfaction when they occur repeatedly. Data came from the German Socio-Economic Panel, a large-scale representative panel study, and were analyzed using multilevel modeling. Results showed that, in general, life satisfaction decreases with repeated unemployment (sensitization). For repeated divorces, life satisfaction is higher at the second divorce than it had been at the first divorce (adaptation). Finally, life satisfaction is similar at repeated marriages. Neuroticism, extraversion, and gender accounted for interindividual differences in changes in life satisfaction. For instance, the general sensitization pattern associated with repeated unemployment was less pronounced for women. The authors also found main effects of age and the duration of the first event on general differences in life satisfaction. Finally, those with repeated events generally report lower life satisfaction than those with only one occasion of these events, even before the first event actually occurred. Findings show that repeated events can have very different effects on life satisfaction that depend on the nature of the event.
Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won
2017-01-01
To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.
Godden, S M; Royster, E; Timmerman, J; Rapnicki, P; Green, H
2017-08-01
Study objectives were to (1) describe the diagnostic test characteristics of an automated milk leukocyte differential (MLD) test and the California Mastitis Test (CMT) to identify intramammary infection (IMI) in early- (EL) and late-lactation (LL) quarters and cows when using 3 different approaches to define IMI from milk culture, and (2) describe the repeatability of MLD test results at both the quarter and cow level. Eighty-six EL and 90 LL Holstein cows were sampled from 3 Midwest herds. Quarter milk samples were collected for a cow-side CMT test, milk culture, and MLD testing. Quarter IMI status was defined by 3 methods: culture of a single milk sample, culture of duplicate samples with parallel interpretation, and culture of duplicate samples with serial interpretation. The MLD testing was completed in duplicate within 8 h of sample collection; MLD results (positive/negative) were reported at each possible threshold setting (1-18 for EL; 1-12 for LL) and CMT results (positive/negative) were reported at each possible cut-points (trace, ≥1, ≥2, or 3). We created 2 × 2 tables to compare MLD and CMT results to milk culture, at both the quarter and cow level, when using each of 3 different definitions of IMI as the referent test. Paired MLD test results were compared with evaluate repeatability. The MLD test showed excellent repeatability. The choice of definition of IMI from milk culture had minor effects on estimates of MLD and CMT test characteristics. For EL samples, when interpreting MLD and CMT results at the quarter level, and regardless of the referent test used, both tests had low sensitivity (MLD = 11.7-39.1%; CMT = 0-52.2%) but good to very good specificity (MLD = 82.1-95.2%; CMT = 68.1-100%), depending on the cut-point used. Sensitivity improved slightly if diagnosis was interpreted at the cow level (MLD = 25.6-56.4%; CMT = 0-72.2%), though specificity generally declined (MLD = 61.8-100%; CMT = 25.0-100%) depending on the cut-point used. For LL samples, when interpreted at the quarter level, both tests had variable sensitivity (MLD = 46.6-84.8%; CMT = 9.6-72.7%) and variable specificity (MLD = 59.2-79.8%; CMT = 52.5-97.3%), depending on the cut-point used. Test sensitivity improved if interpreted at the cow level (MLD = 59.6-86.4%; CMT = 19.1-86.4%), though specificity declined (MLD = 32.4-56.8%; CMT = 14.3-92.3%). Producers considering adopting either test for LL or EL screening programs will need to carefully consider the goals and priorities of the program (e.g., whether to prioritize test sensitivity or specificity) when deciding on the level of interpretation (quarter or cow) and when selecting the optimal cut-point for interpreting test results. Additional validation studies and large randomized field studies will be needed to evaluate the effect of adopting either test in selective dry cow therapy or fresh cow screening programs on udder health, antibiotic use, and economics. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
The Sensitivity of Adolescent Hearing Screens Significantly Improves by Adding High Frequencies.
Sekhar, Deepa L; Zalewski, Thomas R; Beiler, Jessica S; Czarnecki, Beth; Barr, Ashley L; King, Tonya S; Paul, Ian M
2016-09-01
One in 6 US adolescents has high-frequency hearing loss, often related to hazardous noise. Yet, the American Academy of Pediatrics (AAP) hearing screen (500, 1,000, 2,000, 4,000 Hertz) primarily includes low frequencies (<3,000 Hertz). Study objectives were to determine (1) sensitivity and specificity of the AAP hearing screen for adolescent hearing loss and (2) if adding high frequencies increases sensitivity, while repeat screening of initial referrals reduces false positive results (maintaining acceptable specificity). Eleventh graders (n = 134) participated in hearing screening (2013-2014) including "gold-standard" sound-treated booth testing to calculate sensitivity and specificity. Of the 43 referrals, 27 (63%) had high-frequency hearing loss. AAP screen sensitivity and specificity were 58.1% (95% confidence interval 42.1%-73.0%) and 91.2% (95% confidence interval 83.4-96.1), respectively. Adding high frequencies (6,000, 8,000 Hertz) significantly increased sensitivity to 79.1% (64.0%-90.0%; p = .003). Specificity with repeat screening was 81.3% (71.8%-88.7%; p = .003). Adolescent hearing screen sensitivity improves with high frequencies. Repeat testing maintains acceptable specificity. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Robins, Meridith T.; Lu, Julie
2016-01-01
The number of highly caffeinated products has increased dramatically in the past few years. Among these products, highly caffeinated energy drinks are the most heavily advertised and purchased, which has resulted in increased incidences of co-consumption of energy drinks with alcohol. Despite the growing number of adolescents and young adults reporting caffeine-mixed alcohol use, knowledge of the potential consequences associated with co-consumption has been limited to survey-based results and in-laboratory human behavioral testing. Here, we investigate the effect of repeated adolescent (post-natal days P35-61) exposure to caffeine-mixed alcohol in C57BL/6 mice on common drug-related behaviors such as locomotor sensitivity, drug reward and cross-sensitivity, and natural reward. To determine changes in neurological activity resulting from adolescent exposure, we monitored changes in expression of the transcription factor ΔFosB in the dopaminergic reward pathway as a sign of long-term increases in neuronal activity. Repeated adolescent exposure to caffeine-mixed alcohol exposure induced significant locomotor sensitization, desensitized cocaine conditioned place preference, decreased cocaine locomotor cross-sensitivity, and increased natural reward consumption. We also observed increased accumulation of ΔFosB in the nucleus accumbens following repeated adolescent caffeine-mixed alcohol exposure compared to alcohol or caffeine alone. Using our exposure model, we found that repeated exposure to caffeine-mixed alcohol during adolescence causes unique behavioral and neurochemical effects not observed in mice exposed to caffeine or alcohol alone. Based on similar findings for different substances of abuse, it is possible that repeated exposure to caffeine-mixed alcohol during adolescence could potentially alter or escalate future substance abuse as means to compensate for these behavioral and neurochemical alterations. PMID:27380261
Fried, Nathan T; Maxwell, Christina R; Elliott, Melanie B; Oshinsky, Michael L
2017-01-01
Background The blood-brain barrier (BBB) has been hypothesized to play a role in migraine since the late 1970s. Despite this, limited investigation of the BBB in migraine has been conducted. We used the inflammatory soup rat model of trigeminal allodynia, which closely mimics chronic migraine, to determine the impact of repeated dural inflammatory stimulation on BBB permeability. Methods The sodium fluorescein BBB permeability assay was used in multiple brain regions (trigeminal nucleus caudalis (TNC), periaqueductal grey, frontal cortex, sub-cortex, and cortex directly below the area of dural activation) during the episodic and chronic stages of repeated inflammatory dural stimulation. Glial activation was assessed in the TNC via GFAP and OX42 immunoreactivity. Minocycline was tested for its ability to prevent BBB disruption and trigeminal sensitivity. Results No astrocyte or microglial activation was found during the episodic stage, but BBB permeability and trigeminal sensitivity were increased. Astrocyte and microglial activation, BBB permeability, and trigeminal sensitivity were increased during the chronic stage. These changes were only found in the TNC. Minocycline treatment prevented BBB permeability modulation and trigeminal sensitivity during the episodic and chronic stages. Discussion Modulation of BBB permeability occurs centrally within the TNC following repeated dural inflammatory stimulation and may play a role in migraine. PMID:28457145
Gumpu, Manju Bhargavi; Krishnan, Uma Maheswari; Rayappan, John Bosco Balaguru
2017-07-01
Intake of water contaminated with lead (Pb 2+ ) and mercury (Hg 2+ ) ions leads to various toxic effects and health issues. In this context, an amperometric urease inhibition-based biosensor was developed to detect Pb 2+ and Hg 2+ ions in water matrix. The modified Pt/CeO 2 /urease electrode was fabricated by immobilizing CeO 2 nanoparticles and urease using a semi-permeable adsorption layer of nafion. With urea as a substrate, urease catalytic activity was examined through cyclic voltammetry. Further, maximum amperometric inhibitive response of the modified Pt/CeO 2 /urease electrode was observed in the presence of Pb 2+ and Hg 2+ ions due to the urease inhibition at specific potentials of -0.03 and 0 V, respectively. The developed sensor exhibited a detection limit of 0.019 ± 0.001 μM with a sensitivity of 89.2 × 10 -3 μA μM -1 for Pb 2+ ions. A detection limit of 0.018 ± 0.003 with a sensitivity of 94.1 × 10 -3 μA μM -1 was achieved in detecting Hg 2+ ions. The developed biosensor showed a fast response time (<1 s) with a linear range of 0.5-2.2 and 0.02-0.8 μM for Pb 2+ and Hg 2+ ions, respectively. The modified electrode offered a good stability for 20 days with a good repeatability and reproducibility. The developed sensor was used to detect Pb 2+ and Hg 2+ ions contaminating Cauvery river water and the observed results were in good co-ordination with atomic absorption spectroscopic data.
Enhanced glucose biosensor properties of gold nanoparticle-decorated ZnO nanorods
NASA Astrophysics Data System (ADS)
Wang, Zi-Hao; Yang, Chih-Chiang; Su, Yan-Kuin; Ruand, Jian-Long
2017-04-01
As new materials have been reported and more knowledge on detailed mechanism of glucose oxidation has been unveiled, the non-enzymatic glucose sensor keeps coming closer to practical applications. Nanostructures with higher surface specific area has great potential applications in sensing devices ZnO nanoords were synthesized in a hydrothermal method using simply available laboratory chemicals. Results showed that as-synthesized Gold Nanoparticle-decorated ZnO Nanorods possessing higher specific surface area, significantly increased the non-enzyme efficiency which in turn improved the sensing performances. The electrode also demonstrated excellent performance in sensing glucose concentration with remarkable sensitivity (46.6 μA/mM-cm2) and good repeatability. This work is expected to open a new avenue to fabricate non-enzymatic electrochemical sensors of glucose involving co-mediating.
Kawakami, I; Shiraishi, S; Tsuda, M
2002-09-01
Ascidians are lower chordates and their simple tadpole-like larvae share a basic body plan with vertebrates. Newly hatched larvae show no response to a stimulus of light. 4 h after hatching, the larvae were induced to swim upon a step-down of light and stop swimming upon a step-up of light. At weaker intensity of light, the larvae show the same response to a stimulus after presentation of repeated stimuli. When intensity of actinic light was increased, the larvae show sensitization and habituation of the swimming response to a stimulus after repeated stimuli of step-down and step-up of the light. Between 2 h 20 min and 3 h 40 min after hatching the larvae did not show any response to the first stimulus, but after several repeatedstimuli they show swimming response to a step-down of light. A repeated series of stimulus cause sensitization. Between 4 h and 7 h after hatching, the larvae show photoresponse to the first stimulus, but after several repetition of the stimuli, the larvae could not stop swimming to a stimulus of a step-up of the actinic light. A repeated series of stimulus cause greaterhabituation. Both sensitization and habituation depend upon intensity ofactinic light.
Mesoporous Nickel Oxide (NiO) Nanopetals for Ultrasensitive Glucose Sensing
NASA Astrophysics Data System (ADS)
Mishra, Suryakant; Yogi, Priyanka; Sagdeo, P. R.; Kumar, Rajesh
2018-01-01
Glucose sensing properties of mesoporous well-aligned, dense nickel oxide (NiO) nanostructures (NSs) in nanopetals (NPs) shape grown hydrothermally on the FTO-coated glass substrate has been demonstrated. The structural study based investigations of NiO-NPs has been carried out by X-ray diffraction (XRD), electron and atomic force microscopies, energy dispersive X-ray (EDX), and X-ray photospectroscopy (XPS). Brunauer-Emmett-Teller (BET) measurements, employed for surface analysis, suggest NiO's suitability for surface activity based glucose sensing applications. The glucose sensor, which immobilized glucose on NiO-NPs@FTO electrode, shows detection of wide range of glucose concentrations with good linearity and high sensitivity of 3.9 μA/μM/cm2 at 0.5 V operating potential. Detection limit of as low as 1 μΜ and a fast response time of less than 1 s was observed. The glucose sensor electrode possesses good anti-interference ability, stability, repeatability & reproducibility and shows inert behavior toward ascorbic acid (AA), uric acid (UA) and dopamine acid (DA) making it a perfect non-enzymatic glucose sensor.
A gas chromatography-mass spectrometry assay to quantify camphor extracted from goat serum.
Lee, Kyung-Min; Dai, Susie Y; Herrman, Timothy J; Musser, Jeffrey M B
2012-09-15
A sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for quantification and pharmacokinetics of camphor, a major monoterpene of juniper plant, in goat serum. Camphor and internal standard (terpinolene) eluates from solid phase extraction (SPE) with ethyl acetate yielded well resolved peaks and were clearly identified in total and selected ion chromatograms. The elution and injection volumes were optimized for improved detection and quantification of camphor based on peak shape, signal to noise ratio, recoveries, and repeatability. The matrix calibration curve with the good linearity (R(2)=0.998) and response in the range of 0.005-10.0 μg/mL was used to determine camphor concentration in goat serum. The GC-MS method offered sufficiently low limits of detection (1 ng/mL) and quantitation (3 ng/mL) for camphor concentration in goat serum for the pharmacokinetic study. The proposed method showed good intra- and inter-day variation with relative standard deviation (RSD) of 0.2-7.7% and produced good recovery (96.0-111.6%) and reproducibility (1.6-6.1%) at all spiked levels. Using this method on serum samples obtained from two goats orally dosed with camphor confirmed that the method is suitable for camphor studies in animals. Copyright © 2012 Elsevier B.V. All rights reserved.
Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
Tandon, Shishir; Kumar, Satyendra; Sand, N. K.
2015-01-01
This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L−1 with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL−1 and 0.05 ng g−1, respectively. Good linearity (R 2 = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L−1. Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. PMID:25733978
INSECTS AS ALLERGEN INJECTANTS—Severe Reactions to Bites and Stings of Arthropods
Perlman, Frank
1962-01-01
Arthropods capable of penetrating human skin often cause severe local and systemic reactions. Local reactions suggest delayed hypersensitivity while systemic symptoms resemble more the anaphylactic shock in animals. The nature of the antigen remains obscure but predominant evidence suggests its presence throughout the entire organism. Positive history of hypersensitivity to insect injectants was obtained in approximately 20 per cent of persons in the course of routine interviews of 1,078 patients. Repeated bites and stings at long or irregular intervals often induce a state of hypersensitivity, while repeated regular injections of extracts of these insects at shorter intervals may greatly reduce the hypersensitivity. The clinical evidence of allergic sensitivity to insect bites and stings cannot be readily confirmed by skin testing or by other immunological procedures. The history and the character of the lesions as well as certain entomological knowledge of the habits of the insects offer a better basis for specific diagnosis. Treatment with extracts of the whole offending insect generally provides good results but the protection afforded by such treatment varies in degree and duration. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7. PMID:14485406
Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion.
Che, Nanying; Yang, Xinting; Liu, Zichen; Li, Kun; Chen, Xiaoyou
2017-05-01
Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively ( P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS 6110 per ml of pleural effusion and showed good accordance of the results between repeated tests ( r = 0.978, P = 2.84 × 10 -10 ). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. Copyright © 2017 American Society for Microbiology.
Ouyang, Ruizhuo; Zhang, Wangyao; Zhou, Shilin; Xue, Zi-Ling; Xu, Lina; Gu, Yingying; Miao, Yuqing
2013-12-15
We report here the successful fabrication of an improved Bi film wrapped single walled carbon nanotubes modified glassy carbon electrode (Bi/SWNTs/GCE) as a highly sensitive platform for ultratrace Cr(VI) detection through catalytic adsorptive cathodic stripping voltammetry (AdCSV). The introduction of negatively charged SWNTs extraordinarily decreased the size of Bi particles to nanoscale due to electrostatic interaction which made Bi(III) cations easily attracted onto the surface of SWNTs in good order, leading to higher quality of Bi film deposition. The obtained Bi/SWNTs composite was well characterized with electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), the static water contact angle and the voltammetric measurements. The results demonstrates the improvements in the quality of Bi film deposited on the surface of SWNTs such as faster speed of electron transfer, more uniform and smoother morphology, better hydrophilicity and higher stripping signal. Using diethylene triaminepentaacetic acid (DTPA) as complexing ligand, the fabricated electrode displays a well-defined and highly sensitive peak for the reduction of Cr(III)-DTPA complex at -1.06 V ( vs . Ag/AgCl) with a linear concentration range of 0-25 nM and a fairly low detection limit of 0.036 nM. No interference was found in the presence of coexisting ions, and good recoveries were achieved for the analysis of a river sample. In comparison to previous approaches using Bi film modified GCE, the newly designed electrode exhibits better reproducibility and repeatability towards aqueous detection of trace Cr(VI) and appears to be very promising as the basis of a highly sensitive and selective voltammetric procedure for Cr(VI) detection at trace level in real samples.
Zhou, Shilin; Xue, Zi-Ling; Xu, Lina; Gu, Yingying; Miao, Yuqing
2014-01-01
We report here the successful fabrication of an improved Bi film wrapped single walled carbon nanotubes modified glassy carbon electrode (Bi/SWNTs/GCE) as a highly sensitive platform for ultratrace Cr(VI) detection through catalytic adsorptive cathodic stripping voltammetry (AdCSV). The introduction of negatively charged SWNTs extraordinarily decreased the size of Bi particles to nanoscale due to electrostatic interaction which made Bi(III) cations easily attracted onto the surface of SWNTs in good order, leading to higher quality of Bi film deposition. The obtained Bi/SWNTs composite was well characterized with electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), the static water contact angle and the voltammetric measurements. The results demonstrates the improvements in the quality of Bi film deposited on the surface of SWNTs such as faster speed of electron transfer, more uniform and smoother morphology, better hydrophilicity and higher stripping signal. Using diethylene triaminepentaacetic acid (DTPA) as complexing ligand, the fabricated electrode displays a well-defined and highly sensitive peak for the reduction of Cr(III)-DTPA complex at −1.06 V (vs. Ag/AgCl) with a linear concentration range of 0–25 nM and a fairly low detection limit of 0.036 nM. No interference was found in the presence of coexisting ions, and good recoveries were achieved for the analysis of a river sample. In comparison to previous approaches using Bi film modified GCE, the newly designed electrode exhibits better reproducibility and repeatability towards aqueous detection of trace Cr(VI) and appears to be very promising as the basis of a highly sensitive and selective voltammetric procedure for Cr(VI) detection at trace level in real samples. PMID:24771881
Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion
Yang, Xinting; Liu, Zichen; Li, Kun
2017-01-01
ABSTRACT Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively (P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS6110 per ml of pleural effusion and showed good accordance of the results between repeated tests (r = 0.978, P = 2.84 × 10−10). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. PMID:28275073
Smart structure with elastomeric contact surface for prosthetic fingertip sensitivity development
NASA Astrophysics Data System (ADS)
Gu, Chunxin; Liu, Weiting; Yu, Ping; Cheng, Xiaoying; Fu, Xin
2017-09-01
Current flexible/compliant tactile sensors suffer from low sensitivity and high hysteresis introduced by the essential viscosity characteristic of soft material, either used as compliant sensing element or as flexible coverage. To overcome these disadvantages, this paper focuses on developing a tactile sensor with a smart hybrid structure to obtain comprehensive properties in terms of size, compliance, robustness and pressure sensing ability so as to meet the requirements of limited space applications such as prosthetic fingertips. Employing micro-fabricated tiny silicon-based pressure die as the sensing element, it is easy to have both small size and good mechanical performance. To protect it from potential damage and maintain the compliant surface, a rigid base and a soft layer form a sealed chamber and encapsulate the fixed die together with fluid. The fluid serves as highly efficient pressure propagation media of mechanical stimulus from the compliant skin to the pressure die without any hazard impacting the vulnerable connecting wires. To understand the pressure transmission mechanism, a simplified and concise analytic model of a spring system is proposed. Using easy fabrication technologies, a prototype of a 3 × 3 sensor array with total dimensions of 14 mm × 14 mm × 6.5 mm was developed. Based on the quasi-linear relationship between fluid volume and pressure, finite element modeling was developed to analyze the chamber deformation and pressure output of the sensor cell. Experimental tests of the sensor prototype were implemented. The results showed that the sensor cell had good sensing performance with sensitivity of 19.9 mV N-1, linearity of 0.998, repeatability error of 3.41%, and hysteresis error of 3.34%. The force sensing range was from 5 mN to 1.6 N.
Moriya, Jun; Tanno, Yoshihiko; Sugiura, Yoshinori
2013-11-01
This study investigated whether sensitivity to and evaluation of facial expressions varied with repeated exposure to non-prototypical facial expressions for a short presentation time. A morphed facial expression was presented for 500 ms repeatedly, and participants were required to indicate whether each facial expression was happy or angry. We manipulated the distribution of presentations of the morphed facial expressions for each facial stimulus. Some of the individuals depicted in the facial stimuli expressed anger frequently (i.e., anger-prone individuals), while the others expressed happiness frequently (i.e., happiness-prone individuals). After being exposed to the faces of anger-prone individuals, the participants became less sensitive to those individuals' angry faces. Further, after being exposed to the faces of happiness-prone individuals, the participants became less sensitive to those individuals' happy faces. We also found a relative increase in the social desirability of happiness-prone individuals after exposure to the facial stimuli.
Arbyn, Marc; Buntinx, Frank; Van Ranst, Marc; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre; Dillner, Joakim
2004-02-18
The appropriate management of women with minor cytologic lesions in their cervix is unclear. We performed a meta-analysis to assess the accuracy of human papillomavirus (HPV) DNA testing as an alternative to repeat cytology in women who had equivocal results on a previous Pap smear. Data were extracted from articles published between 1992 and 2002 that contained results of virologic and cytologic testing followed by colposcopically directed biopsy in women with an index smear showing atypical cells of undetermined significance (ASCUS). Fifteen studies were identified in which HPV triage and the histologic outcome (presence or absence of a cervical intraepithelial neoplasia of grade II or worse [CIN2+]) was documented. Nine, seven, and two studies also documented the accuracy of repeat cytology when the cutoff for abnormal cytology was set at a threshold of ASCUS or worse, low-grade squamous intraepithelial lesion (LSIL) or worse, or high-grade squamous intraepithelial lesion (HSIL) or worse, respectively. Random-effects models were used for pooling of accuracy parameters in case of interstudy heterogeneity. Differences in accuracy were assessed by pooling the ratio of the sensitivity (or specificity) of HPV testing to that of repeat cytology. The sensitivity and specificity were 84.4% (95% confidence interval [CI] = 77.6% to 91.1%) and 72.9% (95% CI = 62.5% to 83.3%), respectively, for HPV testing overall and 94.8% (95% CI = 92.7% to 96.9%) and 67.3% (95% CI = 58.2% to 76.4%), respectively, for HPV testing in the eight studies that used the Hybrid Capture II assay. Sensitivity and specificity of repeat cytology at a threshold for abnormal cytology of ASCUS or worse was 81.8% (95% CI = 73.5% to 84.3%) and 57.6% (95% CI = 49.5% to 65.7%), respectively. Repeat cytology that used higher cytologic thresholds yielded substantially lower sensitivity but higher specificity than triage with the Hybrid Capture II assay. The ratio of the sensitivity of the Hybrid Capture II assay to that of repeat cytology at a threshold of ASCUS or worse pooled from the four studies that used both triage tests was 1.16 (95% CI = 1.04 to 1.29). The specificity ratio was not statistically different from unity. The published literature indicates that the Hybrid Capture II assay has improved accuracy (higher sensitivity, similar specificity) than the repeat Pap smear using the threshold of ASCUS for an outcome of CIN2+ among women with equivocal cytologic results. The sensitivity of triage at higher cytologic cutoffs is poor.
Chen, I-Cherng; Lin, Shiu-Shiung; Lin, Tsao-Jen; Hsu, Cheng-Liang; Hsueh, Ting Jen; Shieh, Tien-Yu
2010-01-01
The application of novel core-shell nanowires composed of ZnGa2O4/ZnO to improve the sensitivity of NO2 gas sensors is demonstrated in this study. The growth of ZnGa2O4/ZnO core-shell nanowires is performed by reactive evaporation on patterned ZnO:Ga/SiO2/Si templates at 600 °C. This is to form the homogeneous structure of the sensors investigated in this report to assess their sensitivity in terms of NO2 detection. These novel NO2 gas sensors were evaluated at working temperatures of 25 °C and at 250 °C, respectively. The result reveals the ZnGa2O4/ZnO core-shell nanowires present a good linear relationship (R2 > 0.99) between sensitivity and NO2 concentration at both working temperatures. These core-shell nanowire sensors also possess the highest response (<90 s) and recovery (<120 s) values with greater repeatability seen for NO2 sensors at room temperature, unlike traditional sensors that only work effectively at much higher temperatures. The data in this study indicates the newly-developed ZnGa2O4/ZnO core-shell nanowire based sensors are highly promising for industrial applications. PMID:22319286
Angle performance on optima MDxt
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Jonathan; Kamenitsa, Dennis
2012-11-06
Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightlymore » tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).« less
NASA Astrophysics Data System (ADS)
Li, Zhenzhen; Chen, Yan; Xin, Yanmei; Zhang, Zhonghai
2015-11-01
In this work, we proposed to utilize three-dimensional porous copper foam (CF) as conductive substrate and precursor of in-situ growth CuO nanowires (NWs) for fabricating electrochemical nonenzymatic glucose sensors. The CF supplied high surface area due to its unique three-dimensional porous foam structure, and thus resulted in high sensitivity for glucose detection. The CuO NWs/CF based nonenzymatic sensors presented reliable selectivity, good repeatability, reproducibility, and stability. In addition, the CuO NWs/CF based nonenzymatic sensors have been employed for practical applications, and the glucose concentration in human serum was measured to be 4.96 ± 0.06 mM, agreed well with the value measured from the commercial available glucose sensor in hospital, and the glucose concentration in saliva was also estimated to be 0.91 ± 0.04 mM, which indicated that the CuO NWs/CF owned the possibility for noninvasive glucose detection. The rational design of CuO NWs/CF provided an efficient strategy for fabricating of electrochemical nonenzymatic biosensors.
A Hot-Polymer Fiber Fabry–Perot Interferometer Anemometer for Sensing Airflow
Lee, Cheng-Ling; Liu, Kai-Wen; Luo, Shi-Hong; Wu, Meng-Shan; Ma, Chao-Tsung
2017-01-01
This work proposes the first hot-polymer fiber Fabry–Perot interferometer (HPFFPI) anemometer for sensing airflow. The proposed HPFFPI is based on a single-mode fiber (SMF) endface that is attached to a UV-cured polymer to form an ultracompact fiber Fabry–Perot microcavity. The proposed polymer microcavity was heated using a low-cost chip resistor with a controllable dc driving power to achieve a desired polymer’s steady-state temperature (T) that exceeds the T of the surrounding environment. The polymer is highly sensitive to variations of T with high repeatability. When the hot polymer was cooled by the measured flowing air, the wavelength fringes of its optical spectra shifted. The HPFFPI anemometers have been experimentally evaluated for different cavity lengths and heating power values. Experimental results demonstrate that the proposed HPFFPI responses well in terms of airflow measurement. A high sensitivity of 1.139 nm/(m/s) and a good resolution of 0.0088 m/s over the 0~2.54 m/s range of airflow were achieved with a cavity length of 10 μm and a heating power of 0.402 W. PMID:28869510
Miniaturized pH Sensors Based on Zinc Oxide Nanotubes/Nanorods
Fulati, Alimujiang; Ali, Syed M.Usman; Riaz, Muhammad; Amin, Gul; Nur, Omer; Willander, Magnus
2009-01-01
ZnO nanotubes and nanorods grown on gold thin film were used to create pH sensor devices. The developed ZnO nanotube and nanorod pH sensors display good reproducibility, repeatability and long-term stability and exhibit a pH-dependent electrochemical potential difference versus an Ag/AgCl reference electrode over a large dynamic pH range. We found the ZnO nanotubes provide sensitivity as high as twice that of the ZnO nanorods, which can be ascribed to the fact that small dimensional ZnO nanotubes have a higher level of surface and subsurface oxygen vacancies and provide a larger effective surface area with higher surface-to-volume ratio as compared to ZnO nanorods, thus affording the ZnO nanotube pH sensor a higher sensitivity. Experimental results indicate ZnO nanotubes can be used in pH sensor applications with improved performance. Moreover, the ZnO nanotube arrays may find potential application as a novel material for measurements of intracellular biochemical species within single living cells. PMID:22291545
Li, Zhenzhen; Chen, Yan; Xin, Yanmei; Zhang, Zhonghai
2015-01-01
In this work, we proposed to utilize three-dimensional porous copper foam (CF) as conductive substrate and precursor of in-situ growth CuO nanowires (NWs) for fabricating electrochemical nonenzymatic glucose sensors. The CF supplied high surface area due to its unique three-dimensional porous foam structure, and thus resulted in high sensitivity for glucose detection. The CuO NWs/CF based nonenzymatic sensors presented reliable selectivity, good repeatability, reproducibility, and stability. In addition, the CuO NWs/CF based nonenzymatic sensors have been employed for practical applications, and the glucose concentration in human serum was measured to be 4.96 ± 0.06 mM, agreed well with the value measured from the commercial available glucose sensor in hospital, and the glucose concentration in saliva was also estimated to be 0.91 ± 0.04 mM, which indicated that the CuO NWs/CF owned the possibility for noninvasive glucose detection. The rational design of CuO NWs/CF provided an efficient strategy for fabricating of electrochemical nonenzymatic biosensors. PMID:26522446
NASA Astrophysics Data System (ADS)
Taheri, M.; Ahour, F.; Keshipour, S.
2018-06-01
A novel electrochemical sensor based on D-penicillamine anchored nano-cellulose (DPA-NC) modified pencil graphite electrode was fabricated and used for highly selective and sensitive determination of copper (II) ions in the picomolar concentration by square wave adsorptive stripping voltammetric (SWV) method. The modified electrode showed better and increased SWV response compared to the bare and NC modified electrodes which may be related to the porous structure of modifier along with formation of complex between Cu2+ ions and nitrogen or oxygen containing groups in DPA-NC. Optimization of various experimental parameters influence the performance of the sensor, were investigated. Under optimized condition, DPA-NC modified electrode was used for the analysis of Cu2+ in the concentration range from 0.2 to 50 pM, and a lower detection limit of 0.048 pM with good stability, repeatability, and selectivity. Finally, the practical applicability of DPA-NC-PGE was confirmed via measuring trace amount of Cu (II) in tap and river water samples.
Simulation of a Wall-Bounded Flow using a Hybrid LES/RAS Approach with Turbulence Recycling
NASA Technical Reports Server (NTRS)
Quinlan, Jesse R.; Mcdaniel, James; Baurle, Robert A.
2012-01-01
Simulations of a supersonic recessed-cavity flow are performed using a hybrid large-eddy/ Reynolds-averaged simulation approach utilizing an inflow turbulence recycling procedure and hybridized inviscid flux scheme. Calorically perfect air enters the three-dimensional domain at a free stream Mach number of 2.92. Simulations are performed to assess grid sensitivity of the solution, efficacy of the turbulence recycling, and effect of the shock sensor used with the hybridized inviscid flux scheme. Analysis of the turbulent boundary layer upstream of the rearward-facing step for each case indicates excellent agreement with theoretical predictions. Mean velocity and pressure results are compared to Reynolds-averaged simulations and experimental data for each case, and these comparisons indicate good agreement on the finest grid. Simulations are repeated on a coarsened grid, and results indicate strong grid density sensitivity. The effect of turbulence recycling on the solution is illustrated by performing coarse grid simulations with and without inflow turbulence recycling. Two shock sensors, one of Ducros and one of Larsson, are assessed for use with the hybridized inviscid flux reconstruction scheme.
Hybrid Large-Eddy/Reynolds-Averaged Simulation of a Supersonic Cavity Using VULCAN
NASA Technical Reports Server (NTRS)
Quinlan, Jesse; McDaniel, James; Baurle, Robert A.
2013-01-01
Simulations of a supersonic recessed-cavity flow are performed using a hybrid large-eddy/Reynolds-averaged simulation approach utilizing an inflow turbulence recycling procedure and hybridized inviscid flux scheme. Calorically perfect air enters a three-dimensional domain at a free stream Mach number of 2.92. Simulations are performed to assess grid sensitivity of the solution, efficacy of the turbulence recycling, and the effect of the shock sensor used with the hybridized inviscid flux scheme. Analysis of the turbulent boundary layer upstream of the rearward-facing step for each case indicates excellent agreement with theoretical predictions. Mean velocity and pressure results are compared to Reynolds-averaged simulations and experimental data for each case and indicate good agreement on the finest grid. Simulations are repeated on a coarsened grid, and results indicate strong grid density sensitivity. Simulations are performed with and without inflow turbulence recycling on the coarse grid to isolate the effect of the recycling procedure, which is demonstrably critical to capturing the relevant shear layer dynamics. Shock sensor formulations of Ducros and Larsson are found to predict mean flow statistics equally well.
Sublethal Toxicity Endpoints of Heavy Metals to the Nematode Caenorhabditis elegans
Wu, Yue; Wang, Qiang; Li, Huixin
2016-01-01
Caenorhabditis elegans, a free-living nematode, is commonly used as a model organism in ecotoxicological studies. The current literatures have provided useful insight into the relative sensitivity of several endpoints, but few direct comparisons of multiple endpoints under a common set of experimental conditions. The objective of this study was to determine appropriate sublethal endpoints to develop an ecotoxicity screening and monitoring system. C. elegans was applied to explore the sublethal toxicity of four heavy metals (copper, zinc, cadmium and chromium). Two physiological endpoints (growth and reproduction), three behavioral endpoints (head thrash frequency, body bend frequency and feeding) and two enzymatic endpoints (acetylcholine esterase [AChE] and superoxide dismutase [SOD]) were selected for the assessment of heavy metal toxicity. The squared correlation coefficients (R2) between the responses observed and fitted by Logit function were higher than 0.90 and the RMSE were lower than 0.10, indicating a good significance statistically. There was no significant difference among the half effect concentration (EC50) endpoints in physiological and behavioral effects of the four heavy metals, indicating similar sensitivity of physiological and behavioral effects. AChE enzyme was more sensitive to copper, zinc, and cadmium than to other physiological and behavioral effects, and SOD enzyme was most sensitive to chromium. The EC50 of copper, zinc, and cadmium, to the AChE enzyme in the nematodes were 0.68 mg/L, 2.76 mg/L, and 0.92 mg/L respectively and the EC50 of chromium to the SOD enzyme in the nematode was 1.58 mg/L. The results of this study showed that there was a good concentration-response relationship between all four heavy metals and the sublethal toxicity effects to C. elegans. Considering these sublethal endpoints in terms of simplicity, accuracy, repeatability and costs of the experiments, feeding is the relatively ideal sublethal toxicity endpoint of heavy metals to C. elegans. PMID:26824831
Military Research ColorDx and Printed Color Vision Tests.
Almustanyir, Ali; Hovis, Jeffery K
2015-10-01
To determine the equivalence of the ColorDx Military Research version (mColorDx) test and three printed pseudoisochromatic tests (HRR, Ishihara, and PIPIC) for color vision testing. Participating in the study were 75 color-normals and 47 subjects with red-green color vision defects. Color vision was classified by an anomaloscope. The HRR (4(th) edition), Ishihara 38-plate edition, and PIPIC tests are printed color vision tests, whereas mColorDx test figures were displayed on a calibrated computer desktop monitor. All tests were repeated in about 1 wk. The kappa level of agreement (κ) values with the anomaloscope for screening for each test was 0.96 or greater. The values were statistically identical. Specificity for each test was at least 0.99 and sensitivity was at least 0.95. The repeatability of the screening sections for all tests was very good with κ values greater than 0.95. Deutans tended to miss the tritan screening plates on the HRR and mColorDx tests. The Spearman rank correlation coefficients between the severity of the defect and anomaloscope range was moderate with r = 0.45 for the mColorDx and r = 0.6 for the HRR. Both the mColorDx and HRR had perfect agreement with the anomaloscope in classifying the defects as either protan or deutan. The validity of the four tests for color vision screening was statistically identical; however, the HRR may be preferred because it had the highest sensitivity of 0.99, a specificity of 1.0, and a reasonable correlation between the severity rating of the defect and the anomaloscope range.
Measurement of Retinal Sensitivity on Tablet Devices in Age-Related Macular Degeneration.
Wu, Zhichao; Guymer, Robyn H; Jung, Chang J; Goh, Jonathan K; Ayton, Lauren N; Luu, Chi D; Lawson, David J; Turpin, Andrew; McKendrick, Allison M
2015-06-01
We compared measurements of central retinal sensitivity on a portable, low-cost tablet device to the established method of microperimetry in age-related macular degeneration (AMD). A customized test designed to measure central retinal sensitivity (within the central 1° radius) on a tablet device was developed using an open-source platform called PsyPad. A total of 30 participants with AMD were included in this study, and all participants performed a practice test on PsyPad, followed by four tests of one eye and one test of the other eye. Participants then underwent standardized microperimetry examinations in both eyes. The average test duration on PsyPad was 53.9 ± 7.5 seconds, and no significant learning effect was observed over the examinations performed ( P = 1.000). The coefficient of repeatability of central retinal sensitivity between the first two examinations on PsyPad was ±1.76 dB. The mean central retinal sensitivity was not significantly different between PsyPad (25.7 ± 0.4 dB) and microperimetry (26.1 ± 0.4 dB, P = 0.094), and the 95% limits of agreement between the two measures were between -4.12 and 4.92 dB. The measurements of central retinal sensitivity can be performed effectively using a tablet device, displaying reasonably good agreement with those obtained using the established method of microperimetry. These findings highlight the potential of tablet devices as low-cost and portable tools for developing and performing visual function measures that can be easily and widely implemented.
Retrieval and Sleep Both Counteract the Forgetting of Spatial Information
ERIC Educational Resources Information Center
Antony, James W.; Paller, Ken A.
2018-01-01
Repeatedly studying information is a good way to strengthen memory storage. Nevertheless, testing recall often produces superior long-term retention. Demonstrations of this testing effect, typically with verbal stimuli, have shown that repeated retrieval through testing reduces forgetting. Sleep also benefits memory storage, perhaps through…
A Kinematic Calibration Process for Flight Robotic Arms
NASA Technical Reports Server (NTRS)
Collins, Curtis L.; Robinson, Matthew L.
2013-01-01
The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.
Cost-Effectiveness of Osteoporosis Screening Strategies for Men
Nayak, Smita; Greenspan, Susan L.
2016-01-01
Osteoporosis affects many men, with significant morbidity and mortality. However, the best osteoporosis screening strategies for men are unknown. We developed an individual-level state-transition cost-effectiveness model with a lifetime time horizon to identify the cost-effectiveness of different osteoporosis screening strategies for U.S. men involving various screening tests (dual-energy x-ray absorptiometry (DXA); the Osteoporosis Self-Assessment Tool (OST); or a fracture risk assessment strategy using age, femoral neck bone mineral density (BMD), and Vertebral Fracture Assessment (VFA)); screening initiation ages (50, 60, 70, or 80); and repeat screening intervals (5 years or 10 years). In base-case analysis, no screening was a less effective option than all other strategies evaluated; furthermore, no screening was more expensive than all strategies that involved screening with DXA or the OST risk assessment instrument, and thus no screening was “dominated” by screening with DXA or OST at all evaluated screening initiation ages and repeat screening intervals. Screening strategies that most frequently appeared as most cost-effective in base-case analysis and one-way sensitivity analyses when assuming willingness-to-pay of $50,000/QALY or $100,000/QALY included screening initiation at age 50 with the fracture risk assessment strategy and repeat screening every 10 years; screening initiation at age 50 with fracture risk assessment and repeat screening every 5 years; and screening initiation at age 50 with DXA and repeat screening every 5 years. In conclusion, expansion of osteoporosis screening for U.S. men to initiate routine screening at age 50 or 60 would be expected to be effective and of good value for improving health outcomes. A fracture risk assessment strategy using variables of age, femoral neck BMD, and VFA is likely to be the most effective of the evaluated strategies within accepted cost-effectiveness parameters. DXA and OST are also reasonable screening options, albeit likely slightly less effective than the evaluated fracture risk assessment strategy. PMID:26751984
The effects of aging on conflict detection.
Lucci, Giuliana; Berchicci, Marika; Spinelli, Donatella; Taddei, Francesco; Di Russo, Francesco
2013-01-01
Several cognitive changes characterize normal aging; one change regards inhibitory processing and includes both conflict monitoring and response suppression. We attempted to segregate these two aspects within a Go/No-go task, investigating three age categories. Accuracy, response times and event-related potentials (ERPs) were recorded. The ERP data were analyzed, and the Go and No-go trials were separated; in addition, the trials were organized in repeat trials (in which the subjects repeated the action delivered in the previous trial) and switch trials (in which the subjects produced a response opposite to the previous response). We assumed that the switch trials conveyed more conflict than the repeat trials. In general, the behavioral data and slower P3 latencies confirmed the well-known age-related speed/accuracy trade-off. The novel analyses of the repeat vs. switch trials indicated that the age-related P3 slowing was significant only for the high conflict condition; the switch-P3 amplitude increased only in the two older groups. The 'aging switch effect' on the P3 component suggests a failure in the conflict conditions and likely contributes to a generalized dysfunction. The absence of either a switch effect in the young group and the P3 slowing in middle-aged group indicate that switching was not particularly demanding for these participants. The N2 component was less sensitive to the repeat/switch manipulation; however, the subtractive waves also enhanced the age effects in this earlier time window. The topographic maps showed other notable age effects: the frontal No-go N2 was nearly undetectable in the elderly; in the identical time window, a large activity in the posterior and prefrontal scalp regions was observed. Moreover, the prefrontal activity showed a negative correlation with false alarms. These results suggest that the frontal involvement during action suppression becomes progressively dysfunctional with aging, and additional activity was required to reach a good level of accuracy.
Sensitivity of measurement-based purification processes to inner interactions
NASA Astrophysics Data System (ADS)
Militello, Benedetto; Napoli, Anna
2018-02-01
The sensitivity of a repeated measurement-based purification scheme to additional undesired couplings is analyzed, focusing on the very simple and archetypical system consisting of two two-level systems interacting with a repeatedly measured one. Several regimes are considered and in the strong coupling limit (i.e., when the coupling constant of the undesired interaction is very large) the occurrence of a quantum Zeno effect is proven to dramatically jeopardize the efficiency of the purification process.
Repeating and non-repeating fast radio bursts from binary neutron star mergers
NASA Astrophysics Data System (ADS)
Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta
2018-04-01
Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.
Repeating and non-repeating fast radio bursts from binary neutron star mergers
NASA Astrophysics Data System (ADS)
Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta
2018-06-01
Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.
Ren, Ji-Yun; Wang, Xiao-Li; Li, Xiao-Li; Wang, Ming-Lin; Zhao, Ru-Song; Lin, Jin-Ming
2018-02-01
Covalent organic frameworks (COFs), which are a new type of carbonaceous polymeric material, have attracted great interest because of their large surface area and high chemical and thermal stability. However, to the best of our knowledge, no work has reported the use of magnetic COFs as adsorbents for magnetic solid-phase extraction (MSPE) to enrich and determine environmental pollutants. This work aims to investigate the feasibility of using covalent triazine-based framework (CTF)/Fe 2 O 3 composites as MSPE adsorbents to enrich and analyze perfluorinated compounds (PFCs) at trace levels in water samples. Under the optimal conditions, the method developed exhibited low limits of detection (0.62-1.39 ng·L -1 ), a wide linear range (5-4000 ng L -1 ), good repeatability (1.12-9.71%), and good reproducibility (2.45-7.74%). The new method was successfully used to determine PFCs in actual environmental water samples. MSPE based on CTF/Fe 2 O 3 composites exhibits potential for analysis of PFCs at trace levels in environmental water samples. Graphical abstract Magnetic covalent triazine-based frameworks (CTFs) were used as magnetic solid-phase extraction adsorbents for the sensitive determination of perfluorinated compounds in environmental water samples. PFBA perfluorobutyric acid, PFBS perfluorobutane sulfonate, PFDA perfluorodecanoic acid, PFDoA perfluorododecanoic acid, PFHpA perfluoroheptanoic acid, PFHxA perfluorohexanoic acid, PFHxS perfluorohexane sulfonate, PFNA perfluorononanoic acid, PFOA perfluorooctanoic acid, PFPeA perfluoropentanoic acid, PFUdA Perfluoroundecanoic acid.
Detection of pseudorabies virus by duplex droplet digital PCR assay.
Ren, Meishen; Lin, Hua; Chen, Shijie; Yang, Miao; An, Wei; Wang, Yin; Xue, Changhua; Sun, Yinjie; Yan, Yubao; Hu, Juan
2018-01-01
Aujeszky's disease, caused by pseudorabies virus (PRV), has damaged the economy of the Chinese swine industry. A large number of PRV gene-deleted vaccines have been constructed based on deletion of the glycoprotein E ( gE) gene combined with other virulence-related gene deletions, such as thymidine kinase ( TK), whereas PRV wild-type strains contain an intact gE gene. We developed a sensitive duplex droplet digital PCR (ddPCR) assay to rapidly detect PRV wild-type isolates and gE gene-deleted viral vaccines. We compared this assay with a TaqMan real-time PCR (qPCR) using the same primers and probes. Both assays exhibited good linearity and repeatability; however, ddPCR maintained linearity at extremely low concentrations, whereas qPCR did not. Based on positive results for both gE and gB, the detection limit of ddPCR was found to be 4.75 copies/µL in contrast of 76 copies/µL for qPCR, showing that ddPCR provided a 16-fold improvement in sensitivity. In addition, no nonspecific amplification was shown in specificity testing, and the PRV wild-type was distinguished from a gE-deleted strain. The ddPCR was more sensitive when analyzing clinical serum samples. Thus, ddPCR may become an appropriate detection platform for PRV.
Liu, Guanyu; Tan, Qiulin; Kou, Hairong; Zhang, Lei; Wang, Jinqi; Lv, Wen; Dong, Helei; Xiong, Jijun
2018-05-02
Flexible electronics, which can be distributed on any surface we need, are highly demanded in the development of Internet of Things (IoT), robot technology and electronic skins. Temperature is a fundamental physical parameter, and it is an important indicator in many applications. Therefore, a flexible temperature sensor is required. Here, we report a simple method to fabricate three lightweight, low-cost and flexible temperature sensors, whose sensitive materials are reduced graphene oxide (r-GO), single-walled carbon nanotubes (SWCNTs) and multi-wall carbon nanotubes (MWCNTs). By comparing linearity, sensitive and repeatability, we found that the r-GO temperature sensor had the most balanced performance. Furthermore, the r-GO temperature sensor showed good mechanical properties and it could be bent in different angles with negligible resistance change. In addition, the performance of the r-GO temperature sensor remained stable under different kinds of pressure and was unaffected by surrounding environments, like humidity or other gases, because of the insulating layer on its sensitive layer. The easy-fabricated process and economy, together with the remarkable performance of the r-GO temperature sensor, suggest that it is suitable for use as a robot skin or used in the environment of IoT.
Moret, Sabrina; Scolaro, Marianna; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S
2016-04-01
A high throughput, high-sensitivity procedure, involving simultaneous microwave-assisted extraction (MAS) and unsaponifiable extraction, followed by on-line liquid chromatography (LC)-gas chromatography (GC), has been optimised for rapid and efficient extraction and analytical determination of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) in cereal-based products of different composition. MAS has the advantage of eliminating fat before LC-GC analysis, allowing an increase in the amount of sample extract injected, and hence in sensitivity. The proposed method gave practically quantitative recoveries and good repeatability. Among the different cereal-based products analysed (dry semolina and egg pasta, bread, biscuits, and cakes), egg pasta packed in direct contact with recycled paperboard had on average the highest total MOSH level (15.9 mg kg(-1)), followed by cakes (10.4 mg kg(-1)) and bread (7.5 mg kg(-1)). About 50% of the pasta and bread samples and 20% of the biscuits and cake samples had detectable MOAH amounts. The highest concentrations were found in an egg pasta in direct contact with recycled paperboard (3.6 mg kg(-1)) and in a milk bread (3.6 mg kg(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.
Dhara, Keerthy; Ramachandran, T; Nair, Bipin G; Babu, T G Satheesh
2018-06-01
A highly sensitive nonenzymatic hydrogen peroxide (H2O2) sensor was fabricated using platinum nanoparticles decorated reduced graphene oxide (Pt/rGO) nanocomposite. The Pt/rGO nanocomposite was prepared by single-step chemical reduction method. Nanocomposite was characterized by various analytical techniques including Raman spectroscopy, X-ray diffraction, field emission scanning electron microscope and high-resolution transmission electron microscopy. Screen printed electrodes (SPEs) were fabricated and the nanocomposite was cast on the working area of the SPE. Cyclic voltammetry and amperometry demonstrated that the Pt/rGO/SPE displayed much higher electrocatalytic activity towards the reduction of H2O2 than the other modified electrodes. The sensor exhibited wide linear detection range (from 10 μM to 8 mM), very high sensitivity of 1848 μA mM-1 cm-2 and a lower limit of detection of 0.06 μM. The excellent performance of Pt/rGO/SPE sensor were attributed to the reduced graphene oxide being used as an effective matrix to load a number of Pt nanoparticles and the synergistic amplification effect of the two kinds of nanomaterials. Moreover, the sensor showed remarkable features such as good reproducibility, repeatability, long-term stability, and selectivity.
NASA Astrophysics Data System (ADS)
Li, Mingming; Li, Jiheng; Bao, Xiaoqian; Mu, Xing; Gao, Xuexu
2017-07-01
The results of a study on the suitability of Fe-Ga alloys for torque sensor applications are presented. A Fe81Ga19 rod with a ⟨100⟩ preferred orientation along the length direction is prepared for the torque shaft and as the electromagnetic induction sensitive element, which is wound with three coils for signal excitation, signal pickup, and applied bias magnetic field, respectively. An apparent decrease in the induced voltage signal (peak voltage) of 3.88 mV is observed as the torque loading is 50 N m in the presence of a sine excitation signal (10 V, 1 kHz) and a bias current of 0.5 A. Meanwhile, a good repeatability and stress sensitivity are obtained, especially in the low torque range. These behaviors stem from the stress induced decrease in the magnetic permeability and the rotation of the arranged magnetic moment. Here, we use the Fe81Ga19 alloy as the shaft material; nevertheless, in practical use, the same effect can be achieved by forming a Fe-Ga layer with large magnetostriction on the surface of the torsion shaft. This work shows the prospect of Fe-Ga alloys for non-contact torque sensing, for the large magnetostriction and high sensitivity of magnetization to stress.
Karthik, R; Govindasamy, Mani; Chen, Shen-Ming; Mani, Veerappan; Lou, Bih-Show; Devasenathipathy, Rajkumar; Hou, Yu-Shen; Elangovan, A
2016-08-01
A simple and rapid green synthesis using Bischofia javanica Blume leaves as reducing agent was developed for the preparation of gold nanoparticles (AuNPs). AuNPs decorated graphene oxide (AuNPs/GO) was prepared and employed for the sensitive amperometric determination of chloramphenicol. The green biosynthesis requires less than 40s to reduce gold salts to AuNPs. The formations of AuNPs and AuNPs/GO were evaluated by scanning electron and atomic force microscopies, UV-Visible and energy dispersive X-ray spectroscopies, X-ray diffraction studies, and electrochemical methods. AuNPs/GO composite film modified electrode was fabricated and shown excellent electrocatalytic ability towards chloramphenicol. Under optimal conditions, the amperometric sensing platform has delivered wide linear range of 1.5-2.95μM, low detection limit of 0.25μM and high sensitivity of 3.81μAμM(-1)cm(-2). The developed sensor exhibited good repeatability and reproducibility, anti-interference ability and long-term storage stability. Practical feasibility of the sensor has been demonstrated in food samples (milk, powdered milk and honey) and pharmaceutical sample (eye drops). The green synthesized AuNPs/GO composite has great potential for analysis of food samples in food safety measures. Copyright © 2016 Elsevier Inc. All rights reserved.
Zambrana-Infantes, Emma; Rosell Del Valle, Cristina; Ladrón de Guevara-Miranda, David; Galeano, Pablo; Castilla-Ortega, Estela; Rodríguez De Fonseca, Fernando; Blanco, Eduardo; Santín, Luis Javier
2018-03-01
Cocaine addiction is a chronically relapsing disorder characterized by compulsive drug-seeking and drug-taking behaviors. Previous studies have demonstrated that cocaine, as well as other drugs of abuse, alters the levels of lipid-based signaling molecules, such as N-acylethanolamines (NAEs). Moreover, brain levels of NAEs have shown sensitivity to cocaine self-administration and extinction training in rodents. Given this background, the aim of this study was to investigate the effects of repeated or acute administration of palmitoylethanolamide (PEA), an endogenous NAE, on psychomotor sensitization and cocaine-induced contextual conditioning. To this end, the potential ability of repeated PEA administration (1 or 10 mg/kg, i.p.) to modulate the acquisition of cocaine-induced behavioral sensitization (BS) and conditioned place preference (CPP) was assessed in male C57BL/6J mice. In addition, the expression of cocaine-induced BS and CPP following acute PEA administration were also studied. Results showed that repeated administration of both doses of PEA were able to block the acquisition of cocaine-induced BS. Furthermore, acute administration of both doses of PEA was able to abolish the expression of BS, while the highest dose also abolished the expression of cocaine-induced CPP. Taken together, these results indicate that exogenous administration of PEA attenuated psychomotor sensitization, while the effect of PEA in cocaine-induced CPP depended on whether PEA was administered repeatedly or acutely. These findings could be relevant to understand the role that NAEs play in processes underlying the development and maintenance of cocaine addiction. Copyright © 2018 Elsevier Inc. All rights reserved.
Absence of bacterial resistance following repeat exposure to photodynamic therapy
NASA Astrophysics Data System (ADS)
Pedigo, Lisa A.; Gibbs, Aaron J.; Scott, Robert J.; Street, Cale N.
2009-06-01
The prevalence of antibiotic resistant bacteria necessitates exploration of alternative approaches to treat hospital and community acquired infections. The aim of this study was to determine whether bacterial pathogens develop resistance to antimicrobial photodynamic therapy (aPDT) during repeated sub-lethal challenge. Antibiotic sensitive and resistant strains of S. aureus and antibiotic sensitive E. coli were subjected to repeat PDT treatments using a methylene blue photosensitizer formulation and 670 nm illumination from a non-thermal diode laser. Parameters were adjusted such that kills were <100% so that surviving colonies could be passaged for subsequent exposures. With each repeat, kills were compared to those using non-exposed cultures of the same strain. Oxacillin resistance was induced in S. aureus using a disc diffusion method. For each experiment, "virgin" and "repeat" cultures were exposed to methylene blue at 0.01% w/v and illuminated with an energy dose of 20.6 J/cm2. No significant difference in killing of E. coli (repeat vs. virgin culture) was observed through 11 repeat exposures. Similar results were seen using MSSA and MRSA, wherein kill rate did not significantly differ from control over 25 repeat exposures. In contrast, complete oxacillin resistance could be generated in S. aureus over a limited number of exposures. PDT is effective in the eradication of pathogens including antibiotic resistance strains. Furthermore, repeated sub-lethal exposure does not induce resistance to subsequent PDT treatments. The absence of resistance formation represents a significant advantage of PDT over traditional antibiotics.
Intra-session repeatability of lower limb muscles activation pattern during pedaling.
Dorel, Sylvain; Couturier, Antoine; Hug, François
2008-10-01
Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise. Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output=200+/-12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA). No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles. Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing.
Sequence repeats and protein structure
NASA Astrophysics Data System (ADS)
Hoang, Trinh X.; Trovato, Antonio; Seno, Flavio; Banavar, Jayanth R.; Maritan, Amos
2012-11-01
Repeats are frequently found in known protein sequences. The level of sequence conservation in tandem repeats correlates with their propensities to be intrinsically disordered. We employ a coarse-grained model of a protein with a two-letter amino acid alphabet, hydrophobic (H) and polar (P), to examine the sequence-structure relationship in the realm of repeated sequences. A fraction of repeated sequences comprises a distinct class of bad folders, whose folding temperatures are much lower than those of random sequences. Imperfection in sequence repetition improves the folding properties of the bad folders while deteriorating those of the good folders. Our results may explain why nature has utilized repeated sequences for their versatility and especially to design functional proteins that are intrinsically unstructured at physiological temperatures.
NASA Astrophysics Data System (ADS)
Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping
2014-01-01
As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis. Electronic supplementary information (ESI) available: TEM images of individual MB@Au NPs, results of dynamic light scattering analysis and extinction spectrum obtained using colorimetry detection. See DOI: 10.1039/c3nr04942f
Triage of women with low-grade cervical lesions--HPV mRNA testing versus repeat cytology.
Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve
2011-01-01
In Norway, women with low-grade squamous intraepithelial lesions (LSIL) are followed up after six months in order to decide whether they should undergo further follow-up or be referred back to the screening interval of three years. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures. At the University Hospital of North Norway, repeat cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in triage of women with ASC-US and LSIL. In this study, women with LSIL cytology in the period 2005-2008 were included (n = 522). Two triage methods were evaluated in two separate groups: repeat cytology only (n = 225) and HPV mRNA testing in addition to repeat cytology (n = 297). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as the study endpoint. Of 522 women with LSIL, 207 had biopsies and 125 of them had CIN2+. The sensitivity and specificity of repeat cytology (ASC-US or worse) were 85.7% (95% confidence interval (CI): 72.1, 92.2) and 54.4 % (95% CI: 46.9, 61.9), respectively. The sensitivity and specificity of the HPV mRNA test were 94.2% (95% CI: 88.7, 99.7) and 86.0% (95% CI: 81.5, 90.5), respectively. The PPV of repeat cytology was 38.4% (95% CI: 29.9, 46.9) compared to 67.0% (95% CI: 57.7, 76.4) of the HPV mRNA test. HPV mRNA testing was more sensitive and specific than repeat cytology in triage of women with LSIL cytology. In addition, the HPV mRNA test showed higher PPV. These data indicate that the HPV mRNA test is a better triage test for women with LSIL than repeat cytology.
Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.
London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E
1995-01-01
OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143
Thakur, Sahil; Ichhpujani, Parul; Kumar, Suresh; Kaur, Ravneet; Sood, Sunandan
2018-05-14
This study was designed to assess the efficacy, reliability and repeatability of SPARCS (Spaeth Richman Contrast Sensitivity Test) as compared to the conventional Pelli Robson Chart Test for the assessment of contrast sensitivity in patients with glaucoma. We evaluated 135 eyes of 135 patients who were age and sex matched into three groups (controls, disc suspects and glaucoma) of 45 patients each. The glaucoma subgroup was further divided into subgroups of mild, moderate and severe based on the visual field damage. There was a strong positive correlation between Pelli Robson scores and SPARCS scores (S = 0.807, P < 0.001). Intraclass correlation coefficient (ICC) for Pelli Robson Test was 0.952 and 0.988 for SPARCS. The coefficient of repeatability (COR) for mean SPARCS was 5.65%, while COR of Pelli Robson Test was 12.44%. SPARCS was found to have better repeatability than Pelli Robson Test based on COR values. Pelli Robson score had a sensitivity of 80% and a specificity of 65.6% for detecting glaucoma patients as compared to 84.4% and 70%, respectively, for SPARCS scores. SPARCS is a better alternative to conventional Pelli Robson Chart Test for assessment of contrast sensitivity in patients with glaucoma. Being independent of the effects of literacy and educational status, it offers a universal way to measure contrast sensitivity. It can also be reliably used in patients with varying severity of glaucoma.
RHETT/EPDM Performance Characterization
NASA Technical Reports Server (NTRS)
Haag, T.; Osborn, M.
1998-01-01
The 0.6 kW Electric Propulsion Demonstration Module (EPDM) flight thruster system was tested in a large vacuum facility for performance measurements and functional checkout. The thruster was operated at a xenon flow rate of 3.01 mg/s, which was supplied through a self-contained propellant system. All power was provided through a flight-packaged power processing unit, which was mounted in vacuum on a cold plate. The thruster was cycled through 34 individual startup and shutdown sequences. Operating periods ranged from 3 to 3600 seconds. The system responded promptly to each command sequence and there were no involuntary shutdowns. Direct thrust measurements indicated that steady state thrust was temperature sensitive, and varied from a high of 41.7 mN at 16 C, to a low of 34.8 mN at 110 C. Short duration thruster firings showed rapid response and good repeatability.
de Sena, Rodrigo Caciano; Soares, Matheus; Pereira, Maria Luiza Oliveira; da Silva, Rogério Cruz Domingues; do Rosário, Francisca Ferreira; da Silva, Joao Francisco Cajaiba
2011-01-01
The development of a simple, rapid and low cost method based on video image analysis and aimed at the detection of low concentrations of precipitated barium sulfate is described. The proposed system is basically composed of a webcam with a CCD sensor and a conventional dichroic lamp. For this purpose, software for processing and analyzing the digital images based on the RGB (Red, Green and Blue) color system was developed. The proposed method had shown very good repeatability and linearity and also presented higher sensitivity than the standard turbidimetric method. The developed method is presented as a simple alternative for future applications in the study of precipitations of inorganic salts and also for detecting the crystallization of organic compounds. PMID:22346607
A Fiber Bragg Grating Temperature Sensor for 2-400 K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaynetdinov, Madrakhim; See, Erich M.; Geist, Brian
2015-03-01
We demonstrate fiber optic, multiplexible temperature sensing using a fiber Bragg grating (FBG) with an operational range of 2-400 K, and a temperature resolution better than 10 mK for temperatures < 12 K. This represents a significant reduction in the lowest usable temperature as well as a significant increase in sensitivity at cryogenic temperatures compared with previously reported multiplexible solutions. This is accomplished by mounting the section of the fiber with a FBG on a polytetrafluoroethylene coupon, which has a non-negligible coefficient of thermal expansion down to < 4 K. The sensors exhibit a good stability over multiple temperature cyclesmore » and acceptable sensor-to-sensor repeatability. Possible applications for this sensor include distributed temperature sensing across superconducting elements and cryogenic temperature measurements in environments where electrical measurements are impractical or unsafe.« less
A simple method to extract DNA from hair shafts using enzymatic laundry powder.
Guan, Zheng; Zhou, Yu; Liu, Jinchuan; Jiang, Xiaoling; Li, Sicong; Yang, Shuming; Chen, Ailiang
2013-01-01
A simple method to extract DNA from hair shafts was developed by using enzymatic laundry powder at the first step of the process. The whole extraction can be finished in less than 2 hours. The simple extraction reagent proposed here contains only two cheap components: ordinary enzymatic laundry powder and PCR buffer. After extraction, an ultra sensitive fluorescent nucleic acid stain, PicoGreen, was used for quantifying trace amount of double-stranded DNA in the solution extracted. For further validation of DNA extraction, four primers were employed to amplify DNA microsatellite loci. Both fluorescence spectroscopy and PCR results suggested that this method can extract DNA from hair shafts with good efficiency and repeatability. The study will greatly facilitate the use of hair shafts in future for DNA analyses on genome-wide scale.
Kaale, Eliangiringa; Van Schepdael, Ann; Roets, Eugène; Hoogmartens, Jos
2002-11-07
A reversed-phase liquid chromatography (LC) method has been developed, optimised and validated for the separation and quantitation of capsaicin (CP) and dihydrocapsaicin (DHCP) in a topical cream formulation. Sample preparation involves liquid-liquid extraction prior to LC analysis. The method uses a Hypersil C(18) BDS, 5 micrometer, 250x4.6 mm I.D. column maintained at 35 degrees C. The mobile phase comprises methanol, water, acetonitrile (ACN) and acetic acid (47:42:10:1, v/v/v/v) at a flow rate of 1.0 ml/min. Robustness was evaluated by performing a central composite face-centred design (CCF) experiment. The method shows good selectivity, linearity, sensitivity and repeatability. The conditions allow the separation and quantitation of CP and DHCP without interference from the other substances contained in the cream.
Koch, Melissa R.; House, Nealia C. M.; Cosetta, Casey M.; Jong, Robyn M.; Salomon, Christelle G.; Joyce, Cailin E.; Philips, Elliot A.; Su, Xiaofeng A.; Freudenreich, Catherine H.
2018-01-01
CAG/CTG trinucleotide repeats are unstable sequences that are difficult to replicate, repair, and transcribe due to their structure-forming nature. CAG repeats strongly position nucleosomes; however, little is known about the chromatin remodeling needed to prevent repeat instability. In a Saccharomyces cerevisiae model system with CAG repeats carried on a YAC, we discovered that the chromatin remodeler Isw1 is required to prevent CAG repeat expansions during transcription. CAG repeat expansions in the absence of Isw1 were dependent on both transcription-coupled repair (TCR) and base-excision repair (BER). Furthermore, isw1∆ mutants are sensitive to methyl methanesulfonate (MMS) and exhibit synergistic MMS sensitivity when combined with BER or TCR pathway mutants. We conclude that CAG expansions in the isw1∆ mutant occur during a transcription-coupled excision repair process that involves both TCR and BER pathways. We observed increased RNA polymerase II (RNAPII) occupancy at the CAG repeat when transcription of the repeat was induced, but RNAPII binding did not change in isw1∆ mutants, ruling out a role for Isw1 remodeling in RNAPII progression. However, nucleosome occupancy over a transcribed CAG tract was altered in isw1∆ mutants. Based on the known role of Isw1 in the reestablishment of nucleosomal spacing after transcription, we suggest that a defect in this function allows DNA structures to form within repetitive DNA tracts, resulting in inappropriate excision repair and repeat-length changes. These results establish a new function for Isw1 in directly maintaining the chromatin structure at the CAG repeat, thereby limiting expansions that can occur during transcription-coupled excision repair. PMID:29305386
Effects of Sodium Butyrate on Methamphetamine-Sensitized Locomotor Activity
Harkness, John H.; Hitzemann, Robert J.; Edmunds, Stephanie; Phillips, Tamara J.
2012-01-01
Neuroadaptations associated with behavioral sensitization induced by repeated exposure to methamphetamine (MA) appear to be involved in compulsive drug pursuit and use. Increased histone acetylation, an epigenetic effect resulting in altered gene expression, may promote sensitized responses to psychostimulants. The role of histone acetylation in the expression and acquisition of MA-induced locomotor sensitization was examined by measuring the effect of histone deacetylase inhibition by sodium butyrate (NaB). For the effect on expression, vehicle or NaB (630 mg/kg, intraperitoneally) was administered 30 min prior to MA challenge in mice treated repeatedly with MA (10 days of 2 mg/kg MA) or saline (10 days), and then locomotor response to MA challenge was measured. NaB treatment increased the locomotor response to MA in both acutely MA treated and sensitized animals. For acquisition, NaB was administered 30 min prior to each MA exposure (10 days of 1 or 2 mg/kg), but not prior to the MA challenge test. Treatment with NaB during the sensitization acquisition period significantly increased locomotor activation by MA in sensitized mice only. NaB alone did not significantly alter locomotor activity. Acute NaB or MA, but not the combination, appeared to increase striatal acetylation at histone H4. Repeated treatment with MA, but not NaB or MA plus NaB, increased striatal acetylation at histone H3. Although increased histone acetylation may alter the expression of genes involved in acute locomotor response to MA and in the acquisition of MA-induced sensitization, results for acetylation at H3 and H4 showed little correspondence with behavior. PMID:23137698
Nakratzas, G.; Wagenaar, J. P. M.; Reintjes, M.; Scheffer, E.; Swierenga, J.
1974-01-01
Nakratzas, G., Wagenaar, J. P. M., Reintjes, M., Scheffer, E., and Swierenga, J. (1974).Thorax, 29, 125-131. Repeated partial endoscopic resections as treatment for two patients with inoperable tracheal tumours. Two cases of tracheal tumour are described, one a carcinoid and the other an adenoid cystic carcinoma (cylindroma). Both patients were treated by repeated partial bronchoscopic resections. The patients are in good health nine and three years respectively after treatment. Images PMID:4363463
Plasmonic Optical Fiber Sensor Based on Double Step Growth of Gold Nano-Islands
Vasconcelos, Helena
2018-01-01
It is presented the fabrication and characterization of optical fiber sensors for refractive index measurement based on localized surface plasmon resonance (LSPR) with gold nano-islands obtained by single and by repeated thermal dewetting of gold thin films. Thin films of gold deposited on silica (SiO2) substrates and produced by different experimental conditions were analyzed by Scanning Electron Microscope/Dispersive X-ray Spectroscopy (SEM/EDS) and optical means, allowing identifying and characterizing the formation of nano-islands. The wavelength shift sensitivity to the surrounding refractive index of sensors produced by single and by repeated dewetting is compared. While for the single step dewetting, a wavelength shift sensitivity of ~60 nm/RIU was calculated, for the repeated dewetting, a value of ~186 nm/RIU was obtained, an increase of more than three times. It is expected that through changing the fabrication parameters and using other fiber sensor geometries, higher sensitivities may be achieved, allowing, in addition, for the possibility of tuning the plasmonic frequency. PMID:29677108
Lack of behavioral sensitization to repeated cocaine administration from postnatal days 1 to 10.
Meyer, J S; Yacht, A C
1993-09-01
This research determined whether sensitization (or tolerance) to the behavioral effects of cocaine in rat pups would occur following repeated cocaine administration. Rats were injected daily with 20 mg/kg of cocaine HCl s.c. from postnatal day 1 to day 10, injected with saline vehicle only, or left untreated during this period. On day 11, animals from each group were challenged with either 0, .625, 1.25, or 2.50 mg/kg of cocaine and their behavioral responses were recorded. Prior cocaine treatment did not influence the acute effects of cocaine on ultrasonic vocalizations or on any observed motor responses. In contrast, the cocaine- and saline-treated pups differed in a similar manner from the untreated control group on several behavioral measures. These results indicate that the sensitizing effects of repeated cocaine administration are not manifested during the neonatal period. However, the stimulation (stress) of handling and injection may alter the subsequent responsivity of infant rats to a cocaine challenge.
Plasmonic Optical Fiber Sensor Based on Double Step Growth of Gold Nano-Islands.
de Almeida, José M M M; Vasconcelos, Helena; Jorge, Pedro A S; Coelho, Luis
2018-04-20
It is presented the fabrication and characterization of optical fiber sensors for refractive index measurement based on localized surface plasmon resonance (LSPR) with gold nano-islands obtained by single and by repeated thermal dewetting of gold thin films. Thin films of gold deposited on silica (SiO₂) substrates and produced by different experimental conditions were analyzed by Scanning Electron Microscope/Dispersive X-ray Spectroscopy (SEM/EDS) and optical means, allowing identifying and characterizing the formation of nano-islands. The wavelength shift sensitivity to the surrounding refractive index of sensors produced by single and by repeated dewetting is compared. While for the single step dewetting, a wavelength shift sensitivity of ~60 nm/RIU was calculated, for the repeated dewetting, a value of ~186 nm/RIU was obtained, an increase of more than three times. It is expected that through changing the fabrication parameters and using other fiber sensor geometries, higher sensitivities may be achieved, allowing, in addition, for the possibility of tuning the plasmonic frequency.
Grandes, Gonzalo; Bully, Paola; Martinez, Catalina; Gagnon, Marie-Pierre
2017-11-10
Organizational readiness to change healthcare practice is a major determinant of successful implementation of evidence-based interventions. However, we lack of comprehensive, valid, and reliable instruments to measure it. We assessed the validity and reliability of the Spanish version of the Organizational Readiness for Knowledge Translation (OR4KT) questionnaire in the context of the implementation of the Prescribe Vida Saludable III project, which seeks to strengthen health promotion and chronic disease prevention in primary healthcare organizations of the Osakidetza (Basque Health Service, Spain). A cross-sectional study was conducted including 127 professionals from 20 primary care centers within Osakidetza. They filled in the OR4KT questionnaire twice in a 15- to 30-day period to test repeatability. In addition, we used the Survey of Organizational Attributes for Primary Care (SOAPC) and we documented the number of healthcare professionals who formally engaged in the Prescribe Vida Saludable III project within each participating center to assess concurrent validity. Cronbach's alpha for the overall OR4KT was .95, and the overall repeatability coefficient was 6.95%, both excellent results. Confirmatory factor analysis supported the underlying theoretical structure of 6 dimensions and 23 sub-dimensions. There were positive moderate-to-high internal correlations between these six dimensions, and there was evidence of good concurrent validity (correlation coefficient of .76 with SOAPC, and .80 with the proportion of professionals engaged by center). A score higher than 64 (out of 100) would be indicative of an organization with high level of readiness to implement the intervention (sensitivity = .75, specificity = 1). The Spanish version of the OR4KT exhibits very strong reliability and good validity, although it needs to be validated in a larger sample and in different implementation contexts.
Differential effects of context on psychomotor sensitization to ethanol and cocaine.
Didone, Vincent; Quoilin, Caroline; Dieupart, Julie; Tirelli, Ezio; Quertemont, Etienne
2016-04-01
Repeated drug injections lead to sensitization of their stimulant effects in mice, a phenomenon sometimes referred to as drug psychomotor sensitization. Previous studies showed that sensitization to cocaine is context dependent as its expression is reduced in an environment that was not paired with cocaine administration. In contrast, the effects of the test context on ethanol sensitization remain unclear. In the present study, female OF1 mice were repeatedly injected with 1.5 g/kg ethanol to test for both the effects of context novelty/familiarity and association on ethanol sensitization. A first group of mice was extensively pre-exposed to the test context before ethanol sensitization and ethanol injections were paired with the test context (familiar and paired group). A second group was not pre-exposed to the test context, but ethanol injections were paired with the test context (nonfamiliar and paired group). Finally, a third group of mice was not pre-exposed to the test context and ethanol was repeatedly injected in the home cage (unpaired group). Control groups were similarly exposed to the test context, but were injected with saline. In a second experiment, cocaine was used as a positive control. The same behavioral procedure was used, except that mice were injected with 10 mg/kg cocaine instead of ethanol. The results show a differential involvement of the test context in the sensitization to ethanol and cocaine. Cocaine sensitization is strongly context dependent and is not expressed in the unpaired group. In contrast, the expression of ethanol sensitization is independent of the context in which it was administered, but is strongly affected by the relative novelty/familiarity of the environment. Extensive pre-exposure to the test context prevented the expression of ethanol sensitization. One possible explanation is that expression of ethanol sensitization requires an arousing environment.
[Standard sample preparation method for quick determination of trace elements in plastic].
Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa
2011-08-01
Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.
Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping
2014-01-01
As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an "elongate and capture" procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.
Naproxen Attenuates Sensitization of Depressive-Like Behavior and Fever during Maternal Separation
Hennessy, Michael B.; Stafford, Nathan P.; Yusko-Osborne, Brittany; Schiml, Patricia A.; Xanthos, Evan D.; Deak, Terrence
2014-01-01
Early life stress can increase susceptibility for later development of depressive illness though a process thought to involve inflammatory mediators. Isolated guinea pig pups exhibit a passive, depressive-like behavioral response and fever that appear mediated by proinflammatory activity, and which sensitize with repeated separations. Treatment with an anti-inflammatory can attenuate the behavioral response during the initial separation and separation the following day. Here we used the cyclooxygenase inhibitor naproxen to examine the role of prostaglandins in mediating the depressive-like behavior and core body temperature of young guinea pigs during an initial separation, separation the next day, and separation 10 days after the first. The passive, depressive-like behavior as well as fever sensitized with repeated separation. Three days of injection with 14 mg/kg of naproxen prior to the initial separation reduced depressive-like behavior during all three separations. A 28 mg/kg dose of naproxen, however, had minimal effect on behavior. Fever during the early separations was moderated by naproxen, but only at the higher dose. These results suggest a role of prostaglandins in the behavioral and febrile response to maternal separation, and particularly in the sensitization of depressive-like behavior following repeated separation. PMID:25449392
Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord
2012-09-01
The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.
Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan
The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.
EFFECT OF EPISODIC WEEKLY NICOTINE ADMINISTRATION ON REPEATED ACQUISITION IN RATS.
Our prior research showed both tolerance and sensitization to nicotine?s effects on motor activity with weekly dosing. This experiment determined the generality of this finding to conditioned behavior. After extended training on a repeated acquisition/performance schedule all ra...
Jadhav, Sachin; Sattar, Naveed; Petrie, John R; Cobbe, Stuart M; Ferrell, William R
2007-09-01
Interrogation of peripheral vascular function is increasingly recognized as a noninvasive surrogate marker for coronary vascular function and carries with it important prognostic information regarding future cardiovascular risk. Laser Doppler imaging (LDI) is a completely noninvasive method for looking at peripheral microvascular function. We sought to look at reproducibility and repeatability of LDI-derived assessment of peripheral microvascular function between arms and 8 weeks apart. We used LDI in conjunction with iontophoretic application of ACh and SNP to look at endothelium-dependent and -independent microvascular function, respectively, in a mixture of women with cardiac syndrome X and healthy volunteers. We looked at variation between arms (n = 40) and variation at 8 weeks apart (n = 22). When measurements were corrected for skin resistance, there was nonsignificant variation between arms for ACh (2.7%) and SNP (3.8%) and nonsignificant temporal variation for ACh (3.5%) and SNP (4.7%). Construction of Bland-Altman plots reinforce that measurements have good repeatability. Elimination of the baseline perfusion response had deleterious effects on repeatability. LDI can be used to assess peripheral vascular response with good repeatability as long as measurements are corrected for skin resistance, which affects drug delivery. This has important implications for the future use of LDI.
Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi
2016-07-30
We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55-75) with a BMI ≥27 and <40 kg/m², and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student's t-test comparisons. A total of 160 participants were included in the analysis. The Bland-Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of -0.65 and 0.22, respectively (R² = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
Addison, Elena S; Clements, Dylan N
2017-12-01
Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.
Momenbeik, Fariborz; Yazdani, Elham
2015-01-01
Methyl silane coated Fe3O4 magnetic nanoparticles were used for simultaneous extraction of the fat-soluble vitamins (FSVs). The amounts of extracted vitamins were determined by HPLC. The synthesized Fe3O4 nanoparticles were coated with silica and then modified with trimethoxymethylsilane (TMMS). The prepared particles were characterized by different methods. The best amounts of silica and TMMS in sorbent synthesis were 1.2 and 0.5 mL, respectively. The optimum pH values for the sample solution and washing buffer were 5 and 3, respectively. Application of 100 mg sorbent, 700 μL tetrahydrofuran, 5-fold dilution of the sample solution, and 1 min for sorption and desorption times were among the best conditions. At the optimum conditions, the calibration plots for each vitamin were obtained with good linearity (R(2) >0.9992) and suitable linear ranges. This method has a low LOD (<76.1 μg/mL), acceptable repeatability (RSD <5.63%) and reproducibility (RSD <4.71%), and good accuracy (recovery >90.3%). Preconcentration of low concentrations of vitamin D3 was performed, and results showed 3.7 times greater sensitivity after preconcentration. Finally, the amounts of the FSVs in pharmaceutical formulations were determined using the proposed method, and results showed good agreement with those reported by manufacturers.
Wang, Xiaoyu; Wang, Yuan; Qin, Yaqiong; Ding, Li; Chen, Yi; Xie, Fuwei
2015-08-01
A simple method has been developed for the simultaneous determination of 16 polycyclic aromatic hydrocarbons (PAHs) in mainstream cigarette smoke. The procedure is based on employing a homemade graphene-coated solid-phase microextraction (SPME) fiber for extraction prior to GC/MS. In comparison to commercial 100-μm poly(dimethyl siloxane) (PDMS) fiber, the graphene-coated SPME fiber exhibits advantageous cleanup and preconcentration efficiencies. By collecting the particulate phase 5 cigarettes, the LODs and LOQs of 16 target PAHs were 0.02-0.07 and 0.07-0.22 ng/cigarette, respectively, and all of the linear correlation efficiencies were larger than 0.995. The validation results also indicate that the method has good repeatability (RSD between 4.2% and 9.5%) and accuracy (spiked recoveries between 80% and 110%). The developed method was applied to analyze two Kentucky reference cigarettes (1R5F and 3R4F) and six Chinese brands of cigarettes. In addition, the PAH concentrations in the particulate phase of the smoke from the 1R5F Kentucky cigarettes were in good agreement with recently reported results. Due to easy operation and good validation results, this SPME-GC/MS method may be an excellent alternative for trace analysis of PAHs in cigarette smoke. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Fuxin; Liu, Shuqin; Yang, Hao; Zheng, Juan; Qiu, Junlang; Xu, Jianqiao; Tong, Yexiang; Zhu, Fang; Ouyang, Gangfeng
2016-11-01
Graphene, a novel class of carbon nanostructures, has received great attention as sorbents due to its fascinating structures, ultrahigh specific surface area, and good extraction ability. In this paper, a new type of hierarchical graphene was synthesized through employing a mild and environment-friendly method. Such 3D interconnected graphene own a high specific surface area up to 524m(2)g(-1), which is about 2.5 fold larger than the graphene, since the synthetic material has interlayer pores between nanosheets and in-plane pores. Then a superior solid-phase microextraction fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and hierarchical graphene powder. Since the novel hierarchical graphene possessed large surface area and good adsorption property, the as-prepared fiber exhibited good extraction properties of the organochlorine pesticides (OCPs). As for the analytical performance, the as-prepared fiber achieved low detection limits (0.08-0.80ngL(-1)) and wide linearity (10-30,000ngL(-1)) under the optimal conditions. The repeatability (n=5) for single fiber were between 5.1% and 11%, while the reproducibility (n=3) of fiber-to-fiber were range from 6.2% to14%. Moreover, the fiber was successfully applied to the analysis of OCPs in the Pearl River water. Copyright © 2016 Elsevier B.V. All rights reserved.
Kim, Yong Jin; Shin, Jung Ho; Hur, Jun Yong; Kim, Hoon; Ku, Seung-Yup; Suh, Chang Suk
2017-01-01
To evaluate the predictive value of the progesterone level at the beta-human chorionic gonadotropin (β-hCG) check day for ongoing pregnancy maintenance in in vitro fertilization (IVF) cycles in women with previous unexplained repeated miscarriages. One hundred and forty-eight women, with visible gestational sac after IVF, were recruited in this observational study. All subjects had unexplained recurrent miscarriages in more than two previous IVF cycles. The progesterone level at the β-hCG check day (i.e. 14 days after oocyte retrieval) was assessed. The area under the curve (AUC) of the progesterone level was evaluated to predict the ongoing pregnancy or miscarriage outcomes. The overall ongoing pregnancy rate was 60.8% (90/148). The cut-off value with β-hCG levels higher than 126.5 mIU/mL and with progesterone levels higher than 25.2 ng/mL could be the predictive factors for ongoing pregnancy maintenance (AUC = 0.788 and 0.826; sensitivity = 0.788 and 0.723; specificity = 0.689 and 0.833; P < 0.0001 and P < 0.0001, respectively). The miscarriage rates were 19.5% (15/77) in the women with β-hCG > 126.5 mIU/mL and 13.0% (10/77) in those with > 25.2 ng/mL. In the comparison of the ROC curves between both values, a similar significance was found. The subjects with β-hCG > 126.5 mIU/mL and progesterone > 25.2 ng/mL showed higher ongoing pregnancy rates [98.0% (49/50) vs. 41.8% (41/98)] than those with β-hCG ≤ 126.5 mIU/mL or progesterone ≤ 25.2 ng/mL. The progesterone level at 14 days after oocyte retrieval can be a good predictive marker for ongoing pregnancy maintenance in women with repeated IVF failure with miscarriage, together with the β-hCG level. The combined cut-off value of progesterone > 25.2 ng/mL and β-hCG > 126.5 mIU/mL may suggest a good prognosis.
Ultra-sensitive suspended atomically thin-layered black phosphorus mercury sensors.
Li, Peng; Zhang, Dongzhi; Jiang, Chuanxing; Zong, Xiaoqi; Cao, Yuhua
2017-12-15
The extraordinary properties of black phosphorus (BP) make it a promising candidate for next-generation transistor chemical sensors. However, BP films reported so far are supported on substrate, and substrate scattering drastically deteriorates its electrical properties. Consequentially, the potential sensing capability of intrinsic BP is highly underestimated and its sensing mechanism is masked. Additionally, the optimum sensing regime of BP remains unexplored. This article is the first demonstration of suspended BP sensor operated in subthreshold regime. BP exhibited significant enhancement of sensitivity for ultra-low-concentration mercury detection in the absence of substrate, and the sensitivity reached maximum in subthreshold regime. Without substrate scattering, the suspended BP device demonstrated 10 times lower 1/f noise which contributed to better signal-to-noise ratio. Therefore, rapid label-free trace detection of Hg 2+ was achieved with detection limit of 0.01 ppb, lower than the world health organization (WHO) tolerance level (1 ppb). The time constant for ion detection extracted was 3s. Additionally, experimental results revealed that good stability, repeatability, and selectivity were achieved. BP sensors also demonstrated the ability of detecting mercury ions in environment water samples. The underling sensing mechanism of intrinsic BP was ascribed to the carrier density variation resulted from surface charge gating effect, so suspended BP in subthreshold regime with optimum gating effect demonstrated the best sensitivity. Our results show the prominent advantages of intrinsic BP as a sensing material. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Zhang, Lei; Huang, Youju; Wang, Jingyun; Rong, Yun; Lai, Weihua; Zhang, Jiawei; Chen, Tao
2015-05-19
Gold nanoparticles (AuNPs) labeled lateral-flow test strip immunoassay (LFTS) has been widely used in biomedical, feed/food, and environmental analysis fields. Conventional ILFS assay usually uses spherical AuNPs as labeled probes and shows low detection sensitivity, which further limits its widespread practical application. Unlike spherical AuNP used as labeled probe in conventional ILFS, in our present study, a hierarchical flowerlike AuNP specific probe was designed for LFTS and further used to detect Escherichia coli O157:H7 (E. coli O157:H7). Three types of hierarchical flowerlike AuNPs, such as tipped flowerlike, popcornlike, and large-sized flowerlike AuNPs were synthesized in a one-step method. Compared with other two kinds of Au particles, tipped flowerlike AuNPs probes for LFTS particularly exhibited highly sensitive detection of E. coli O157:H7. The remarkable improvement of detection sensitivity of tipped flowerlike AuNPs probes can be achieved even as low as 10(3) colony-forming units (CFU)/mL by taking advantages of its appropriate size and hierarchical structures, which is superior over the detection performance of conventional LFTS. Using this novel tipped flower AuNPs probes, quantitative detection of E. coli O157:H7 can be obtained partially in a wide concentration range with good repeatability. This hierarchical tipped flower-shaped AuNPs probe for LFTS is promising for the practical applications in widespread analysis fields.
Highly sensitive refractive index sensor based on a TiO2 nanowire array.
Li, Qiu-Shun; Xiang, Dong; Chang, Zhi-Min; Shi, Jian-Guo; Ma, Yao-Hong; Cai, Lei; Feng, Dong; Dong, Wen-Fei
2017-03-01
We propose a novel, highly sensitive refractive index (RI) sensor by means of combining the Kretschmann prism with a TiO2 nanowire array and do not use a metallic layer in the Kretschmann configuration. Its RI sensing performance was investigated through measuring different concentrations of sodium chloride solution. Experimental results showed that, with increasing RI of liquid, the resonant wavelength in the reflectance spectrum redshifted gradually in the visible light range. There was a very good linear relationship between resonant wavelength and RI in the range of 1.3330 to 1.3546. More importantly, in contrast to the surface plasmon resonance (SPR) sensor, the interferometric sensors showed higher sensitivity to the external RI. In the case of the transverse magnetic mode, the RI sensitivity is up to 320,700.93 a.u./RIU (refractive index unit) by expression of light intensity, which is 9.55 times that of the SPR sensor. As for the transverse electric mode, it achieves 4371.76 nm/RIU by expression of the resonant wavelength, which is increased by a factor of 1.4 in comparison with the SPR sensor. Moreover, the experimental results have favorable repeatability. A TiO2 nanowire array sensor has also other advantages, such as easy manufacturing, low cost, and in situ determination, etc. To our knowledge, this fact is reported for the first time. It has great potential applications in the field of biological and chemical sensing.
van de Wetering, Ross; Schenk, Susan
2017-04-01
Repeated exposure to ±3, 4-methylenedioxymethamphetamine (MDMA) produces sensitization to MDMA-produced hyperactivity, but the mechanisms underlying the development of this sensitized response or the relationship to the reinforcing effects of MDMA is unknown. This study determined the effect of a sensitizing regimen of MDMA exposure on the acquisition of MDMA self-administration and investigated the role of dopamine D 2 receptor mechanisms. Rats received the selective D 2 antagonist, eticlopride (0.0 or 0.3 mg/kg, i.p.) and MDMA (0.0 or 10.0 mg/kg, i.p.) during a five-day pretreatment regimen. Two days following the final session, the locomotor activating effects of MDMA (5 mg/kg, i.p.) and the latency to acquisition of MDMA self-administration were determined. Pretreatment with MDMA enhanced the locomotor activating effects of MDMA and facilitated the acquisition of MDMA self-administration. Administration of eticlopride during MDMA pretreatment completely blocked the development of sensitization to MDMA-produced hyperactivity but failed to significantly alter the facilitated acquisition of MDMA self-administration. Pretreatment with eticlopride alone facilitated the acquisition of self-administration. These data suggest that repeated MDMA exposure sensitized both the locomotor activating and reinforcing effects of MDMA. Activation of D 2 receptors during MDMA pretreatment appears critical for the development of sensitization to MDMA-produced hyperactivity. The role of D 2 receptor mechanisms in the development of sensitization to the reinforcing effects of MDMA is equivocal.
Rylatt, Louise; Cartwright, Tina
2016-04-01
Poor childhood diet is a major risk factor for disease and obesity, and parents of pre-school children are in a powerful position to influence diet for life. The technique of thematic synthesis (Thomas & Harden, 2008) was used to synthesise recent qualitative research on parental feeding of pre-school age children (18 months-6 years). The aim was to inform development of nutrition advice by gaining a comprehensive picture of parental feeding behaviours and motivations. Six key parental feeding behaviours were identified: modelling, rewards, pressure and encouragement, repeated exposure, creativity, and limiting intake. Four overarching themes regarding motivations were identified: promoting good health (balance and variety, and weight control); building positive relationships (child involvement, and parental engagement and responsiveness); practicalities and constraints (time, cost, and lack of culinary skill, and pressure and flexibility); and emotional motivations (problem avoidance, and emotional investment). Practicalities and constraints, and emotional motivations impacted more significantly on low income parents. In order to be effective, nutrition advice ought to tap into parents' strong desire to build positive relationships and promote good health while remaining sensitive to the significant constraints and practicalities faced. Copyright © 2015. Published by Elsevier Ltd.
Wu, Baoyan; Hou, Shihua; Miao, Zhiying; Zhang, Cong; Ji, Yanhong
2015-09-18
A novel amperometric glucose biosensor was fabricated by layer-by-layer self-assembly of gold nanorods (AuNRs) and glucose oxidase (GOD) onto single-walled carbon nanotubes (SWCNTs)-functionalized three-dimensional sol-gel matrix. A thiolated aqueous silica sol containing SWCNTs was first assembled on the surface of a cleaned Au electrode, and then the alternate self-assembly of AuNRs and GOD were repeated to assemble multilayer films of AuNRs-GOD onto SWCNTs-functionalized silica gel for optimizing the biosensor. Among the resulting glucose biosensors, the four layers of AuNRs-GOD-modified electrode showed the best performance. The sol-SWCNTs-(AuNRs- GOD)₄/Au biosensor exhibited a good linear range of 0.01-8 mM glucose, high sensitivity of 1.08 μA/mM, and fast amperometric response within 4 s. The good performance of the proposed glucose biosensor could be mainly attributed to the advantages of the three-dimensional sol-gel matrix and stereo self-assembly films, and the natural features of one-dimensional nanostructure SWCNTs and AuNRs. This study may provide a new facile way to fabricate the enzyme-based biosensor with high performance.
Zhang, Hui; Yin, Yajing; Wu, Ping; Cai, Chenxin
2012-01-15
Choline, as a marker of cholinergic activity in brain tissue, is very important in biological and clinical analysis, especially in the clinical detection of the neurodegenerative disorders disease. This work presents an electrochemical approach for the detection of choline based on prussian blue modified iron phosphate nanostructures (PB-FePO(4)). The obtained nanostructures showed a good catalysis toward the electroreduction of H(2)O(2), and an amperometric choline biosensor was developed by immobilizing choline oxidase on the PB-FePO(4) nanostructures. The biosensor exhibited a rapid response (ca. 2s), low detection limit (0.4±0.05 μM), wide linear range (2 μM to 3.2 mM), high sensitivity (~75.2 μAm M(-1) cm(-2)), as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid and 4-acetamidophenol did not cause obvious interference due to the low detection potential (-0.05 V versus saturated calomel electrode). This nanostructure could be used as a promise platform for the construction of other oxidase-based biosensors. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mao, Hui; Song, Jinling; Zhang, Qian; Liu, Daliang; Gong, Naiqi; Li, Ying; Wu, Qiong; Verpoort, Francis; Song, Xi-Ming
2013-05-01
Copolymerization of styrene (St) and 1-vinyl-3-ethylimidazolium bromide (VEIB), novel poly(St-co-VEIB) microspheres were generated. Owing to the presence of imidazolium groups, such microspheres having an average diameter of 125 nm, behave electropositively when dispersed in aqueous solution. Furthermore, due to the presence of imidazolium groups, having a capacity of ion-exchange and weak reducibility on the surface of the PS microspheres, [Fe(CN)6]3- was absorbed on the surface of poly(St-co-VEIB) microspheres, and simultaneously, Fe3+ was reduced to Fe2+. Thus, in situ growth of Prussian blue (PB) nanoparticles could occur on the surface of poly(St-co-VEIB) microspheres without the addition of any other reducing agent. This methodology, utilizing the ion-exchange and weak reducibility properties of the imidazolium groups on the surface of micro-/nanostructures is a novel general method for assembling hierarchical nanostructured materials. Finally, the electrochemical property of the strawberry-like PS/PB composite microspheres was also investigated by applying a glassy carbon electrode. A good repeatability of the cyclic voltammetry responses, having a good linearity and sensitivity, for the electrocatalytic reduction of H2O2 was obtained.
Brondani, Daniela; Scheeren, Carla Weber; Dupont, Jairton; Vieira, Iolanda Cruz
2012-08-21
Halloysite clay nanotubes were used as a support for the immobilization of the enzyme peroxidase from clover sprouts (Trifolium), and employed together with platinum nanoparticles in 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid (Pt-BMI·PF(6)) in the development of a new biosensor for the determination of catecholamines by square-wave voltammetry. Under optimized conditions, the analytical curves showed detection limits of 0.05, 0.06, 0.07, 0.12 μM for dopamine, isoproterenol, dobutamine and epinephrine, respectively. The biosensor demonstrated high sensitivity, good repeatability and reproducibility, and long-term stability (18% decrease in response over 150 days). A recovery study of dopamine in pharmaceutical samples gave values from 97.5 to 101.4%. The proposed biosensor was successfully applied to the determination of dopamine in pharmaceutical samples, with a maximum relative error of ±1.0% in relation to the standard (spectrophotometric) method. The good analytical performance of the proposed method can be attributed to the efficient immobilization of the peroxidase in the nanoclay, and the facilitation of electron transfer between the protein and the electrode surface due to the presence of the Pt nanoparticles and ionic liquid.
Zhou, Guisheng; Pang, Hanqing; Tang, Yuping; Yao, Xin; Mo, Xuan; Zhu, Shaoqing; Guo, Sheng; Qian, Dawei; Qian, Yefei; Su, Shulan; Zhang, Li; Jin, Chun; Qin, Yong; Duan, Jin-ao
2013-05-01
This work presented a new analytical methodology based on hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry in multiple-reaction monitoring mode for analysis of 24 underivatized free amino acids (FAAs) in functional foods. The proposed method was first reported and validated by assessing the matrix effects, linearity, limit of detections and limit of quantifications, precision, repeatability, stability and recovery of all target compounds, and it was used to determine the nutritional substances of FAAs in ginkgo seeds and further elucidate the nutritional value of this functional food. The result showed that ginkgo seed turned out to be a good source of FAAs with high levels of several essential FAAs and to have a good nutritional value. Furthermore, the principal component analysis was performed to classify the ginkgo seed samples on the basis of 24 FAAs. As a result, the samples could be mainly clustered into three groups, which were similar to areas classification. Overall, the presented method would be useful for the investigation of amino acids in edible plants and agricultural products.
Application of the pressure sensitive paint technique to steady and unsteady flow
NASA Technical Reports Server (NTRS)
Shimbo, Y.; Mehta, R.; Cantwell, B.
1996-01-01
Pressure sensitive paint is a newly-developed optical measurement technique with which one can get a continuous pressure distribution in much shorter time and lower cost than a conventional pressure tap measurement. However, most of the current pressure sensitive paint applications are restricted to steady pressure measurement at high speeds because of the small signal-to-noise ratio at low speed and a slow response to pressure changes. In the present study, three phases of work have been completed to extend the application of the pressure sensitive paint technique to low-speed testing and to investigate the applicability of the paint technique to unsteady flow. First the measurement system using a commercially available PtOEP/GP-197 pressure sensitive paint was established and applied to impinging jet measurements. An in-situ calibration using only five pressure tap data points was applied and the results showed good repeatability and good agreement with conventional pressure tap measurements on the whole painted area. The overall measurement accuracy in these experiments was found to be within 0.1 psi. The pressure sensitive paint technique was then applied to low-speed wind tunnel tests using a 60 deg delta wing model with leading edge blowing slots. The technical problems encountered in low-speed testing were resolved by using a high grade CCD camera and applying corrections to improve the measurement accuracy. Even at 35 m/s, the paint data not only agreed well with conventional pressure tap measurements but also clearly showed the suction region generated by the leading edge vortices. The vortex breakdown was also detected at alpha=30 deg. It was found that a pressure difference of 0.2 psi was required for a quantitative pressure measurement in this experiment and that temperature control or a parallel temperature measurement is necessary if thermal uniformity does not hold on the model. Finally, the pressure sensitive paint was applied to a periodically changing pressure field with a 12.8s time period. A simple first-order pole model was applied to deal with the phase lag of the paint. The unsteady pressure estimated from the time-changing pressure sensitive paint data agreed well with the pressure transducer data in regions of higher pressure and showed the possibility of extending the technique to unsteady pressure measurements. However, the model still needs further refinement based on the physics of the oxygen diffusion into the paint layer and the oxygen quenching on the paint luminescence.
Design and implementation of a micromechanical silicon resonant accelerometer.
Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing
2013-11-19
The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C.
Utilization of optical emission endpoint in photomask dry etch processing
NASA Astrophysics Data System (ADS)
Faure, Thomas B.; Huynh, Cuc; Lercel, Michael J.; Smith, Adam; Wagner, Thomas
2002-03-01
Use of accurate and repeatable endpoint detection during dry etch processing of photomask is very important for obtaining good mask mean-to-target and CD uniformity performance. It was found that the typical laser reflectivity endpoint detecting system used on photomask dry etch systems had several key limitations that caused unnecessary scrap and non-optimum image size performance. Consequently, work to develop and implement use of a more robust optical emission endpoint detection system for chrome dry etch processing of photomask was performed. Initial feasibility studies showed that the emission technique was sensitive enough to monitor pattern loadings on contact and via level masks down to 3 percent pattern coverage. Additional work was performed to further improve this to 1 percent pattern coverage by optimizing the endpoint detection parameters. Comparison studies of mask mean-to-target performance and CD uniformity were performed with the use of optical emission endpoint versus laser endpoint for masks built using TOK IP3600 and ZEP 7000 resist systems. It was found that an improvement in mean-to-target performance and CD uniformity was realized on several types of production masks. In addition, part-to-part endpoint time repeatability was found to be significantly improved with the use of optical emission endpoint.
Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong
2012-04-18
To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.
New Tunneling Features in Polar III-Nitride Resonant Tunneling Diodes
NASA Astrophysics Data System (ADS)
Encomendero, Jimy; Faria, Faiza Afroz; Islam, S. M.; Protasenko, Vladimir; Rouvimov, Sergei; Sensale-Rodriguez, Berardi; Fay, Patrick; Jena, Debdeep; Xing, Huili Grace
2017-10-01
For the past two decades, repeatable resonant tunneling transport of electrons in III-nitride double barrier heterostructures has remained elusive at room temperature. In this work we theoretically and experimentally study III-nitride double-barrier resonant tunneling diodes (RTDs), the quantum transport characteristics of which exhibit new features that are unexplainable using existing semiconductor theory. The repeatable and robust resonant transport in our devices enables us to track the origin of these features to the broken inversion symmetry in the uniaxial crystal structure, which generates built-in spontaneous and piezoelectric polarization fields. Resonant tunneling transport enabled by the ground state as well as by the first excited state is demonstrated for the first time over a wide temperature window in planar III-nitride RTDs. An analytical transport model for polar resonant tunneling heterostructures is introduced for the first time, showing a good quantitative agreement with experimental data. From this model we realize that tunneling transport is an extremely sensitive measure of the built-in polarization fields. Since such electric fields play a crucial role in the design of electronic and photonic devices, but are difficult to measure, our work provides a completely new method to accurately determine their magnitude for the entire class of polar heterostructures.
HPV test by Hybrid Capture II for the diagnosis of HR-HPV persistent infection.
Serour, Y; Bendahmane, M; Abbou Baker, F; Medles, M; Moueddene, B; Kraiba, R
2017-11-01
Persistent high-risk HPV (HR-HPV) infection is associated with a greater risk of cervical cancer. Statistical data on the prevalence of HR-HPV infections in the Algerian population is lacking. We conducted a prospective study of 300 women aged between 25 and 50 years, screened for cervical cancer from 2012 to 2015 in Sidi Bel Abbès, a western region of Algeria. We aimed to assess the reliability of the repeated use of the HC II test (three longitudinal HPV tests 9 months apart from each other) in diagnosing the persistence of HR-HPV infection. The prevalence of HR-HPV infection was 7.33% and infected women were aged 37.9±3years. For 90.9% of HR-HPV-positive patients, the infection persisted for a mean of 18.5months [95% CI: 16.9-22.1months]. Among these patients, 55.55% developed CIN1 and 11.11% developed CIN2. The sensitivity of the HC II test was 81.74% [95% CI: 71.3-89.6] and its positive predictive value associated with abnormal cervical biopsy was 27.49% [95% CI: 16.0-33.33]. Repeating the HC II test is a good predictor for identifying women at high risk of cervical cancer. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Orthogonal Comparison of GC-MS and 1H NMR Spectroscopy for Short Chain Fatty Acid Quantitation.
Cai, Jingwei; Zhang, Jingtao; Tian, Yuan; Zhang, Limin; Hatzakis, Emmanuel; Krausz, Kristopher W; Smith, Philip B; Gonzalez, Frank J; Patterson, Andrew D
2017-08-01
Short chain fatty acids (SCFAs) are important regulators of host physiology and metabolism and may contribute to obesity and associated metabolic diseases. Interest in SCFAs has increased in part due to the recognized importance of how production of SCFAs by the microbiota may signal to the host. Therefore, reliable, reproducible, and affordable methods for SCFA profiling are required for accurate identification and quantitation. In the current study, four different methods for SCFA (acetic acid, propionic acid, and butyric acid) extraction and quantitation were compared using two independent platforms including gas chromatography coupled with mass spectrometry (GC-MS) and 1 H nuclear magnetic resonance (NMR) spectroscopy. Sensitivity, recovery, repeatability, matrix effect, and validation using mouse fecal samples were determined across all methods. The GC-MS propyl esterification method exhibited superior sensitivity for acetic acid and butyric acid measurement (LOD < 0.01 μg mL -1 , LOQ < 0.1 μg mL -1 ) and recovery accuracy (99.4%-108.3% recovery rate for 100 μg mL -1 SCFA mixed standard spike in and 97.8%-101.8% recovery rate for 250 μg mL -1 SCFAs mixed standard spike in). NMR methods by either quantitation relative to an internal standard or quantitation using a calibration curve yielded better repeatability and minimal matrix effects compared to GC-MS methods. All methods generated good calibration curve linearity (R 2 > 0.99) and comparable measurement of fecal SCFA concentration. Lastly, these methods were used to quantitate fecal SCFAs obtained from conventionally raised (CONV-R) and germ free (GF) mice. Results from global metabolomic analysis of feces generated by 1 H NMR and bomb calorimetry were used to further validate these approaches.
A two-question tool to assess the risk of repeated falls in the elderly
Gálvez-Barrón, César; Narvaiza, Leire; Miñarro, Antonio; Ruiz, Jorge; Valldosera, Esther; Gonzalo, Natalia; Ng, Thalia; Sanguino, María Jesús; Yuste, Antonio
2017-01-01
Introduction Older adults’ perception of their own risk of fall has never been included into screening tools. The goal of this study was to evaluate the predictive validity of questions on subjects’ self-perception of their own risk of fall. Methods This prospective study was conducted on a probabilistic sample of 772 Spanish community-dwelling older adults, who were followed-up for a one year period. At a baseline visit, subjects were asked about their recent history of falls (question 1: “Have you fallen in the last 6 months?”), as well as on their perception of their own risk of fall by using two questions (question 2: “Do you think you may fall in the next few months?” possible answers: yes/no; question 3: “What is the probability that you fall in the next few months?” possible answers: low/intermediate/high). The follow-up consisted of quarterly telephone calls, where the number of falls occurred in that period was recorded. Results A short questionnaire built with questions 1 and 3 showed 70% sensitivity (95% CI: 56%-84%), 72% specificity (95% CI: 68%-76%) and 0.74 area under the ROC curve (95% CI: 0.66–0.82) for prediction of repeated falls in the subsequent year. Conclusions The estimation of one’s own risk of fall has predictive validity for the occurrence of repeated falls in older adults. A short questionnaire including a question on perception of one’s own risk of fall and a question on the recent history of falls had good predictive validity. PMID:28489888
Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.
Morgan, Timothy M; Case, L Douglas
2013-07-05
In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.
Diniz, Michele B; Lima, Luciana Monti; Eckert, George; Zandona, Andrea G Ferreira; Cordeiro, Rita C L; Pinto, Lourdes Santos
2011-01-01
This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10× occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0–6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and interexaminer repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.
The Visi-Chroma VC-100: a new imaging colorimeter for dermatocosmetic research.
Barel, A O; Clarys, P; Alewaeters, K; Duez, C; Hubinon, J L; Mommaerts, M
2001-02-01
It was the aim of this study to carry out a comparative evaluation in vitro on standardized color charts and in vivo on healthy subjects using the Visi-Chroma VC-100, a new imaging tristimulus colorimeter and the Minolta Chromameter CR-200 as a reference instrument. The Visi-Chroma combines tristimulus color analysis with full color visualization of the skin area measured. The technical performances of both instruments were compared with the purpose of validating the use of this new imaging colorimeter in dermatocosmetic research. In vitro L*a*b* color parameters were taken with both instruments on standardized color charts (Macbeth and RAL charts) in order to evaluate accuracy, sensitivity range and repeatability. These measurements were completed by in vivo studies on different sites of human skin and studies of color changes induced by topical chemical agents on forearm skin. The accuracy, sensitivity range and repeatability of measurements of selected distances and surfaces in the measuring zone considered and specific color determinations of specific skin zones were also determined. The technical performance of this imaging colorimeter was rather good, with low coefficients of variation for repeatability of in vitro and vivo color measurements. High positive correlations were established in vitro and in vivo over a wide range of color measurements. The imaging colorimeter was able to measure the L*a*b* color parameters of specific chosen parts of the skin area considered and to measure accurately selected distances and surfaces in the same skin site considered. These comparative measurements show that both instruments have very similar technical performances and that high levels of correlation were obtained in vitro and in vivo using the L*a*b* color parameters. In addition, the Visi-Chroma presents the following improvements: 1) direct visualization and recording of the skin area considered with concomitant color measurements; 2) determination of the specific color parameters of skin areas chosen in the total measuring area; and 3) accurate determination of selected distances and surfaces in the same skin areas chosen.
Hu, Zhixiong; Cheng, Peng; Guo, Mingli; Zhang, Weinong; Qi, Yutang
2013-07-10
A novel approach of periodate oxidation coupled with high-performance liquid chromatography (HPLC)-fluorescence detection (FLD) for the quantitative determination of 3-chloro-1,2-propanediol (3-MCPD) has been established. The essence of this approach lies in the production of chloroacetaldehyde by the oxidization cleavage of 3-MCPD with sodium periodate and the HPLC analysis of chloroacetaldehyde monitored by an FLD detector after fluorescence derivatization with adenine. The experimental parameters relating to the efficiency of the derivative reaction such as concentration of adenine, chloroacetaldehyde reaction temperature, and time were studied. Under the optimized conditions, the proposed method can provide high sensitivity, good linearity (r(2) = 0.999), and repeatability (percent relative standard deviations between 2.57% and 3.44%), the limits of detection and quantification were 0.36 and 1.20 ng/mL, respectively, and the recoveries obtained for water samples were in the range 93.39-97.39%. This method has been successfully applied to the analysis of real water samples. Also this method has been successfully used for the analysis of vegetable oil samples after pretreatment with liquid-liquid extraction; the recoveries obtained by a spiking experiment with soybean oil ranged from 96.27% to 102.42%. In comparison with gas chromatography or gas chromatography-mass spectrometry, the proposed method can provide the advantages of simple instrumental requirement, easy operation, low cost, and high efficiency, thus making this approach another good choice for the sensitive determination of 3-MCPD.
Suh, Joon Hyuk; Han, Sang Beom; Wang, Yu
2018-02-02
Despite their importance in pivotal signaling pathways due to trace quantities and complex matrices, the analysis of plant hormones is a challenge. Here, to improve this issue, we present an electromembrane extraction technology combined with liquid chromatography-tandem mass spectrometry for determination of acidic plant hormones including jasmonic acid, abscisic acid, salicylic acid, benzoic acid, gibberellic acid and gibberellin A 4 in plant tissues. Factors influencing extraction efficiency, such as voltage, extraction time and stirring rate were optimized using a design of experiments. Analytical performance was evaluated in terms of specificity, linearity, limit of quantification, precision, accuracy, recovery and repeatability. The results showed good linearity (r 2 > 0.995), precision and acceptable accuracy. The limit of quantification ranged from 0.1 to 10 ng mL -1 , and the recoveries were 34.6-50.3%. The developed method was applied in citrus leaf samples, showing better clean-up efficiency, as well as higher sensitivity compared to a previous method using liquid-liquid extraction. Organic solvent consumption was minimized during the process, making it an appealing method. More noteworthy, electromembrane extraction has been scarcely applied to plant tissues, and this is the first time that major plant hormones were extracted using this technology, with high sensitivity and selectivity. Taken together, this work gives not only a novel sample preparation platform using an electric field for plant hormones, but also a good example of extracting complex plant tissues in a simple and effective way. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 1065.526 - Repeating void modes or test intervals.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... shut down, restart the engine. (2) Use good engineering judgment to restart the test sequence using the...
40 CFR 1065.526 - Repeating of void modes or test intervals.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... follows: (1) If the engine has stalled or been shut down, restart the engine. (2) Use good engineering...
40 CFR 1065.526 - Repeating void modes or test intervals.
Code of Federal Regulations, 2012 CFR
2012-07-01
... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... shut down, restart the engine. (2) Use good engineering judgment to restart the test sequence using the...
Triage of Women with Low-Grade Cervical Lesions - HPV mRNA Testing versus Repeat Cytology
Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve
2011-01-01
Background In Norway, women with low-grade squamous intraepithelial lesions (LSIL) are followed up after six months in order to decide whether they should undergo further follow-up or be referred back to the screening interval of three years. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures. Materials and Methods At the University Hospital of North Norway, repeat cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in triage of women with ASC-US and LSIL. In this study, women with LSIL cytology in the period 2005–2008 were included (n = 522). Two triage methods were evaluated in two separate groups: repeat cytology only (n = 225) and HPV mRNA testing in addition to repeat cytology (n = 297). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as the study endpoint. Results Of 522 women with LSIL, 207 had biopsies and 125 of them had CIN2+. The sensitivity and specificity of repeat cytology (ASC-US or worse) were 85.7% (95% confidence interval (CI): 72.1, 92.2) and 54.4 % (95% CI: 46.9, 61.9), respectively. The sensitivity and specificity of the HPV mRNA test were 94.2% (95% CI: 88.7, 99.7) and 86.0% (95% CI: 81.5, 90.5), respectively. The PPV of repeat cytology was 38.4% (95% CI: 29.9, 46.9) compared to 67.0% (95% CI: 57.7, 76.4) of the HPV mRNA test. Conclusion HPV mRNA testing was more sensitive and specific than repeat cytology in triage of women with LSIL cytology. In addition, the HPV mRNA test showed higher PPV. These data indicate that the HPV mRNA test is a better triage test for women with LSIL than repeat cytology. PMID:21918682
Hsiao, K M; Lin, H M; Pan, H; Li, T C; Chen, S S; Jou, S B; Chiu, Y L; Wu, M F; Lin, C C; Li, S Y
1999-01-01
Myotonic dystrophy (DM) is caused by a CTG trinucleotide expansion mutation at exon 15 of the myotonic dystrophy protein kinase gene. The clinical severity of this disease correlates with the length of the CTG trinucleotide repeats. Determination of the CTG repeat length has been primarily relied on by Southern blot analysis of restriction enzyme-digested genomic DNA. The development of PCR-based Southern blotting methodology provides a much more sensitive and simpler protocol for DM diagnosis. However, the quality of the template and the high (G+C) ratio of the amplified region hamper the use of PCR on the diagnosis of DM. A modified PCR protocol to amplify different lengths of CTG repeat region using various concentrations of 7deaza-dGTP has been reported (1). Here we describe a procedure including sample collection, DNA purification, and PCR analysis of CTG repeat length without using 7-deaza-dGTP. This protocol is very sensitive and convenient because only a small number of nucleate cells are needed for detection of CTG expansion. Therefore, it could be very useful in clinical and prenatal diagnosis as well as in prevalence study of DM.
Diamond-based electrochemical aptasensor realizing a femtomolar detection limit of bisphenol A.
Ma, Yibo; Liu, Junsong; Li, Hongdong
2017-06-15
In this study, we designed and fabricated an electrochemical impedance aptasensor based on Au nanoparticles (Au-NPs) coated boron-doped diamond (BDD) modified with aptamers, and 6-mercapto-1-hexanol (MCH) for the detection of bisphenol A (BPA). The constructed BPA aptasensor exhibits good linearity from 1.0×10 -14 to 1.0×10 -9 molL -1 . The detection limitation of 7.2×10 -15 molL -1 was achieved, which can be attributed to the synergistic effect of combining BDD with Au-NPs, aptamers, and MCH. The examine results of BPA traces in Tris-HCl buffer and in milk, UV spectra of aptamer/BPA and interference test revealed that the novel aptasensors are of high sensitivity, specificity, stability and repeatability, which could be promising in practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Breath analysis using external cavity diode lasers: a review
NASA Astrophysics Data System (ADS)
Bayrakli, Ismail
2017-04-01
Most techniques that are used for diagnosis and therapy of diseases are invasive. Reliable noninvasive methods are always needed for the comfort of patients. Owing to its noninvasiveness, ease of use, and easy repeatability, exhaled breath analysis is a very good candidate for this purpose. Breath analysis can be performed using different techniques, such as gas chromatography mass spectrometry (MS), proton transfer reaction-MS, and selected ion flow tube-MS. However, these devices are bulky and require complicated procedures for sample collection and preconcentration. Therefore, these are not practical for routine applications in hospitals. Laser-based techniques with small size, robustness, low cost, low response time, accuracy, precision, high sensitivity, selectivity, low detection limit, real-time, and point-of-care detection have a great potential for routine use in hospitals. In this review paper, the recent advances in the fields of external cavity lasers and breath analysis for detection of diseases are presented.
Castañeda, María; Odriozola, Adrián; Gómez, Javier; Zarrabeitia, María T
2013-07-01
We report the development of an effective system for analyzing X chromosome-linked mini short tandem repeat loci with reduced-size amplicons (less than 220 bp), useful for analyzing highly degraded DNA samples. To generate smaller amplicons, we redesigned primers for eight X-linked microsatellites (DXS7132, DXS10079, DXS10074, DXS10075, DXS6801, DXS6809, DXS6789, and DXS6799) and established efficient conditions for a multiplex PCR system (miniX). The validation tests confirmed that it has good sensitivity, requiring as little as 20 pg of DNA, and performs well with DNA from paraffin-embedded tissues, thus showing potential for improved analysis and identification of highly degraded and/or very limited DNA samples. Consequently, this system may help to solve complex forensic cases, particularly when autosomal markers convey insufficient information.
Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang
2015-01-01
This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.
Fisher, M S; Menter, J M; Willis, I
1989-03-01
Contact hypersensitivity (CHS) in mice can be induced by cutaneous sensitization followed by elicitation via ear-painting with trinitrochlorobenzene (TNCB). This CHS reaction is systemic and can be suppressed by exposure of mice to suberythemogenic doses of 280-315 nm radiation. In this study, we investigated whether a commercially available water-resistant sunscreen, either SPF-6 or SPF-15, containing Padimate O (UVB absorber) and oxybenzone (UVA absorber), was effective in preventing systemic suppression of CHS induced by either FS36 sunlamp exposure or solar simulating radiation. We observed that these two sunscreen preparations were totally incapable of preventing the immunologic suppression of contact hypersensitivity by UV radiation. These results indicate that application of sunscreen does not retard the development of suppression of CHS following repeated UV exposure under conditions where erythema is not clinically observed. Thus, erythema may not be a good end point for assessing systemic immune suppression and its consequences.
Geoelectrical mapping and groundwater contamination
NASA Astrophysics Data System (ADS)
Blum, Rainer
Specific electrical resistivity of near-surface materials is mainly controlled by the groundwater content and thus reacts extremely sensitive to any change in the ion content. Geoelectric mapping is a well-established, simple, and inexpensive technique for observing areal distributions of apparent specific electrical resistivities. These are a composite result of the true resistivities in the underground, and with some additional information the mapping of apparent resistivities can help to delineate low-resistivity groundwater contaminations, typically observed downstream from sanitary landfills and other waste sites. The presence of other good conductors close to the surface, mainly clays, is a serious noise source and has to be sorted out by supporting observations of conductivities in wells and geoelectric depth soundings. The method may be used to monitor the extent of groundwater contamination at a specific time as well as the change of a contamination plume with time, by carrying out repeated measurements. Examples for both are presented.
NASA Astrophysics Data System (ADS)
Wang, Youqing; Shen, Changyu; Lou, Weimin; Shentu, Fengying; Zhong, Chuan; Dong, Xinyong; Tong, Limin
2016-07-01
A fiber optic relative humidity (RH) sensor based on the tilted fiber Bragg grating (TFBG) coated with graphene oxide (GO) film was presented. Amplitudes of the cladding mode resonances of the TFGB varies with the water sorption and desorption processes of the GO film, because of the strong interactions between the excited backward propagating cladding modes and the GO film. By detecting the transmission intensity changes of the cladding mode resonant dips at the wavelength of 1557 nm, the maximum sensitivity of 0.129 dB/%RH with a linear correlation coefficient of 99% under the RH range of 10-80% was obtained. The Bragg mode of TFBG can be used as power or wavelength references, since it is inherently insensitive to RH changes. In addition, the proposed humidity sensor shows a good performance in repeatability and stability.
A new ring-shaped graphite monitor ionization chamber
NASA Astrophysics Data System (ADS)
Yoshizumi, M. T.; Caldas, L. V. E.
2010-07-01
A ring-shaped monitor ionization chamber was developed at the Instituto de Pesquisas Energéticas e Nucleares. This ionization chamber presents an entrance window of aluminized polyester foil. The guard ring and collecting electrode are made of graphite coated Lucite plates. The main difference between this new ionization chamber and commercial monitor chambers is its ring-shaped design. The new monitor chamber has a central hole, allowing the passage of the direct radiation beam without attenuation; only the penumbra radiation is measured by the sensitive volume. This kind of ionization chamber design has already been tested, but using aluminium electrodes. By changing the electrode material from aluminium to a graphite coating, an improvement in the chamber response stability was expected. The pre-operational tests, as saturation curve, recombination loss and polarity effect showed satisfactory results. The repeatability and the long-term stability tests were also evaluated, showing good agreement with international recommendations.
In-flight photogrammetric camera calibration and validation via complementary lidar
NASA Astrophysics Data System (ADS)
Gneeniss, A. S.; Mills, J. P.; Miller, P. E.
2015-02-01
This research assumes lidar as a reference dataset against which in-flight camera system calibration and validation can be performed. The methodology utilises a robust least squares surface matching algorithm to align a dense network of photogrammetric points to the lidar reference surface, allowing for the automatic extraction of so-called lidar control points (LCPs). Adjustment of the photogrammetric data is then repeated using the extracted LCPs in a self-calibrating bundle adjustment with additional parameters. This methodology was tested using two different photogrammetric datasets, a Microsoft UltraCamX large format camera and an Applanix DSS322 medium format camera. Systematic sensitivity testing explored the influence of the number and weighting of LCPs. For both camera blocks it was found that when the number of control points increase, the accuracy improves regardless of point weighting. The calibration results were compared with those obtained using ground control points, with good agreement found between the two.
The inodilator levosimendan in repetitive doses in the treatment of advanced heart failure
Delgado, Juan F.; Oliva, Fabrizio; Reinecke, Alexander
2017-01-01
Abstract Inotropes may be an appropriate response for some patients with advanced heart failure who remain highly symptomatic despite optimization of evidence-based therapy. These patients need to be supported waiting for a heart transplant or ventricular assist device, or may be candidates for inotropy as an intervention in its own right to maintain a patient in the best achievable circumstances. Objectives in such a situation include relieving symptoms, improving quality of life and reducing unplanned hospitalizations and the costs associated with such admissions. Levosimendan, a calcium sensitizer and potassium channel opener with inotrope and vasodilator actions, has emerged as a potentially valuable addition to the armamentarium in this context, used in repeated or intermittent cycles of therapy. Detailed proposals and guidance are offered for the identification of candidate patients with good prospects of a beneficial response to levosimendan, and for the safe and effective implementation of a course of therapy. PMID:29249905
Peptide Modified ZnO Nanoparticles as Gas Sensors Array for Volatile Organic Compounds (VOCs)
Mascini, Marcello; Gaggiotti, Sara; Della Pelle, Flavio; Di Natale, Corrado; Qakala, Sinazo; Iwuoha, Emmanuel; Pittia, Paola; Compagnone, Dario
2018-01-01
In this work a peptide based gas sensor array based of ZnO nanoparticles (ZnONPs) has been realized. Four different pentapeptides molecularly modeled for alcohols and esters having cysteine as a common spacer have been immobilized onto ZnONPs. ZnONPs have been morphologically and spectroscopically characterized. Modified nanoparticles have been then deposited onto quartz crystal microbalances (QCMs) and used as gas sensors with nitrogen as carrier gas. Analysis of the pure compounds modeled demonstrated a nice fitting of modeling with real data. The peptide based ZnONPs had very low sensitivity to water, compared to previously studied AuNPs peptide based gas sensors allowing the use of the array on samples with high water content. Real samples of fruit juices have been assayed; stability of the signal, good repeatability, and discrimination ability of the array was achieved. PMID:29713626
Peptide Modified ZnO Nanoparticles as Gas Sensors Array for Volatile Organic Compounds (VOCs).
Mascini, Marcello; Gaggiotti, Sara; Della Pelle, Flavio; Di Natale, Corrado; Qakala, Sinazo; Iwuoha, Emmanuel; Pittia, Paola; Compagnone, Dario
2018-01-01
In this work a peptide based gas sensor array based of ZnO nanoparticles (ZnONPs) has been realized. Four different pentapeptides molecularly modeled for alcohols and esters having cysteine as a common spacer have been immobilized onto ZnONPs. ZnONPs have been morphologically and spectroscopically characterized. Modified nanoparticles have been then deposited onto quartz crystal microbalances (QCMs) and used as gas sensors with nitrogen as carrier gas. Analysis of the pure compounds modeled demonstrated a nice fitting of modeling with real data. The peptide based ZnONPs had very low sensitivity to water, compared to previously studied AuNPs peptide based gas sensors allowing the use of the array on samples with high water content. Real samples of fruit juices have been assayed; stability of the signal, good repeatability, and discrimination ability of the array was achieved.
Peptide modified ZnO nanoparticles as gas sensors array for volatile organic compounds (VOCs)
NASA Astrophysics Data System (ADS)
Mascini, Marcello; Gaggiotti, Sara; Della Pelle, Flavio; Di Natale, Corrado; Qakala, Sinazo; Iwuoha, Emmanuel; Pittia, Paola; Compagnone, Dario
2018-04-01
In this work a peptide based gas sensor array based of ZnO nanoparticles (ZnONPs) has been realized. Four different pentapeptides molecularly modelled for alcohols and esters having cysteine as a common spacer have been immobilized onto ZnONPs. ZnONPs have been morphologically and spectroscopically characterized. Modified nanoparticles have been then deposited onto quartz crystal microbalances (QCMs) and used as gas sensors with nitrogen as carrier gas. Analysis of the pure compounds modelled demonstrated a nice fitting of modelling with real data. The peptide based ZnONPs had very low sensitivity to water, compared to previously studied AuNPs peptide based gas sensors allowing the use of the array on samples with high water content. Real samples of fruit juices have been assayed; stability of the signal, good repeatability and discrimination ability of the array was achieved.
NASA Astrophysics Data System (ADS)
Gu, Huajie; Duan, Nuo; Wu, Shijia; Hao, Liling; Xia, Yu; Ma, Xiaoyuan; Wang, Zhouping
2016-02-01
Okadaic acid (OA) is a low-molecular-weight marine toxin from shellfish that causes abdominal pain, vomiting and diarrhea, i.e., diarrheic shellfish poisoning. In this study, a ssDNA aptamer that specifically binds to OA with high affinity was obtained via Systematic Evolution of Ligands by Exponential Enrichment (SELEX) assisted by graphene oxide (GO). This aptamer was then applied to fabricate a novel direct competitive enzyme-linked aptamer assay (ELAA). At the optimized conditions, this ELAA method showed a low detection limit (LOD of 0.01 ng/mL), wide linear range (from 0.025 to 10 ng/mL), good recovery rate (92.86-103.34% in OA-spiked clam samples) and repeatability (RSD of 2.28-4.53%). The proposed method can be used to detect OA in seafood products with high sensitivity and can potentially be adapted for the determination of other small molecular analytes.
Apetrei, Irina Mirela; Apetrei, Constantin
2013-01-01
A biosensor comprising tyrosinase immobilized on a single-walled carbon nanotube-modified glassy carbon electrode has been developed. The sensitive element, ie, tyrosinase, was immobilized using a drop-and-dry method followed by cross-linking. Tyrosinase maintained high bioactivity on this nanomaterial, catalyzing the oxidation of epinephrine to epinephrine-quinone, which was electrochemically reduced (−0.07 V versus Ag/AgCl) on the biosensor surface. Under optimum conditions, the biosensor showed a linear response in the range of 10–110 μM. The limit of detection was calculated to be 2.54 μM with a correlation coefficient of 0.977. The repeatability, expressed as the relative standard deviation for five consecutive determinations of 10−5 M epinephrine solution was 3.4%. A good correlation was obtained between results obtained by the biosensor and those obtained by ultraviolet spectrophotometric methods. PMID:24348034
Alcohol biosensing by polyamidoamine (PAMAM)/cysteamine/alcohol oxidase-modified gold electrode.
Akin, Mehriban; Yuksel, Merve; Geyik, Caner; Odaci, Dilek; Bluma, Arne; Höpfner, Tim; Beutel, Sascha; Scheper, Thomas; Timur, Suna
2010-01-01
A highly stable and sensitive amperometric alcohol biosensor was developed by immobilizing alcohol oxidase (AOX) through Polyamidoamine (PAMAM) dendrimers on a cysteamine-modified gold electrode surface. Ethanol determination is based on the consumption of dissolved oxygen content due to the enzymatic reaction. The decrease in oxygen level was monitored at -0.7 V vs. Ag/AgCl and correlated with ethanol concentration. Optimization of variables affecting the system was performed. The optimized ethanol biosensor showed a wide linearity from 0.025 to 1.0 mM with 100 s response time and detection limit of (LOD) 0.016 mM. In the characterization studies, besides linearity some parameters such as operational and storage stability, reproducibility, repeatability, and substrate specificity were studied in detail. Stability studies showed a good preservation of the bioanalytical properties of the sensor, 67% of its initial sensitivity was kept after 1 month storage at 4 degrees C. The analytical characteristics of the system were also evaluated for alcohol determination in flow injection analysis (FIA) mode. Finally, proposed biosensor was applied for ethanol analysis in various alcoholic beverage as well as offline monitoring of alcohol production through the yeast cultivation. Copyright 2010 American Institute of Chemical Engineers
Al-Fakih, Ebrahim A.; Abu Osman, Noor Azuan; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-01-01
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ∼0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction. PMID:23941909
Yu, Hong-Wei; Jiang, Jing-Hui; Zhang, Ze; Wan, Guang-Cai; Liu, Zhi-Yong; Chang, Dong; Pan, Hong-Zhi
2017-02-15
The assembly of quantum dots (QDs) in a simply method opens up opportunities to obtain access to the full potential of assembled QDs by virtue of the collective properties of the ensembles. In this study, quantum dots CdTe and graphene (Gr) nanocomposite was constructed for the simultaneous determination of uric acid (UA) and dopamine (DA). The CdTe QDs-Gr nanocomposite was prepared by ultrasonication and was characterized with microscopic techniques. The nanocomposite modified electrode was characterized by cyclicvoltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Due to the synergistic effects between CdTe QDs and Gr, the fabricated electrode exhibited excellent electrochemical catalytic activities, good biological compatibility and high sensitivity toward the oxidation of UA and DA. Under optimum conditions, in the co-existence system the linear calibration plots for UA and DA were obtained over the range of 3-600 μM and 1-500 μM with detection limits of 1.0 μM and 0.33 μM. The fabricated biosensor also exhibits the excellent repeatability, reproducibility, storage stability along with acceptable selectivity. Copyright © 2016. Published by Elsevier Inc.
A simple preparation of graphite/gelatin composite for electrochemical detection of dopamine.
Rajkumar, Chellakannu; Thirumalraj, Balamurugan; Chen, Shen-Ming; Chen, His-An
2017-02-01
In this study, we demonstrate a simple preparation of graphite (GR) sheets assisted with gelatin (GLN) polypeptide composite was developed for sensitive detection of dopamine (DA) sensor. The GR/GLN composite was prepared by GR powder in GLN solution (5mg/mL) via sonication process. The prepared GR/GLN composite displays well dispersion ability in biopolymer matrix and characterized via scanning electron microscope (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS) studies. The GR/GLN modified electrode showed an excellent electrocatalytic activity toward the oxidation of DA, suggesting that the successful formation of GR sheets crosslinked with the functional groups of GLN polypeptide. In addition, the GR/GLN modified electrode achieved a wide linear response ranging from 0.05 to 79.5μM with a detection limit of 0.0045μM. The calculated analytical sensitivity of the sensor was 1.36±0.02μAμM -1 cm -2 . Conversely, the modified electrode demonstrates a good storage stability, reproducibility and repeatability. In addition, the sensor manifests the determination of DA in human serum and urine samples for practical applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of a Moisture-in-Solid-Insulation Sensor for Power Transformers
García, Belén; García, Diego; Robles, Guillermo
2015-01-01
Moisture is an important variable that must be kept under control to guarantee a safe operation of power transformers. Because of the hydrophilic character of cellulose, water mainly remains in the solid insulation, while just a few parts per million are dissolved in oil. The distribution of moisture between paper and oil is not static, but varies depending on the insulation temperature, and thus, water migration processes take place continuously during transformers operation. In this work, a sensor is presented that allows the determination of the moisture content of the transformer solid insulation in the steady state and during the moisture migration processes. The main objective of the design is that the electrodes of the sensor should not obstruct the movement of water from the solid insulation to the oil, so the proposed prototype uses a metallic-mesh electrode to do the measurements. The measurement setup is based on the characterization of the insulation dielectric response by means of the frequency dielectric spectroscopy (FDS) method. The sensitivity of the proposed sensor has been tested on samples with a moisture content within 1% to 5%, demonstrating the good sensitivity and repeatability of the measurements. PMID:25658393
Development of a moisture-in-solid-insulation sensor for power transformers.
García, Belén; García, Diego; Robles, Guillermo
2015-02-04
Moisture is an important variable that must be kept under control to guarantee a safe operation of power transformers. Because of the hydrophilic character of cellulose, water mainly remains in the solid insulation, while just a few parts per million are dissolved in oil. The distribution of moisture between paper and oil is not static, but varies depending on the insulation temperature, and thus, water migration processes take place continuously during transformers operation. In this work, a sensor is presented that allows the determination of the moisture content of the transformer solid insulation in the steady state and during the moisture migration processes. The main objective of the design is that the electrodes of the sensor should not obstruct the movement of water from the solid insulation to the oil, so the proposed prototype uses a metallic-mesh electrode to do the measurements. The measurement setup is based on the characterization of the insulation dielectric response by means of the frequency dielectric spectroscopy (FDS) method. The sensitivity of the proposed sensor has been tested on samples with a moisture content within 1% to 5%, demonstrating the good sensitivity and repeatability of the measurements.
Al-Fakih, Ebrahim A; Osman, Noor Azuan Abu; Eshraghi, Arezoo; Adikan, Faisal Rafiq Mahamd
2013-08-12
This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
Hong, Juree; Lee, Sanggeun; Seo, Jungmok; Pyo, Soonjae; Kim, Jongbaeg; Lee, Taeyoon
2015-02-18
A polymer membrane-coated palladium (Pd) nanoparticle (NP)/single-layer graphene (SLG) hybrid sensor was fabricated for highly sensitive hydrogen gas (H2) sensing with gas selectivity. Pd NPs were deposited on SLG via the galvanic displacement reaction between graphene-buffered copper (Cu) and Pd ion. During the galvanic displacement reaction, graphene was used as a buffer layer, which transports electrons from Cu for Pd to nucleate on the SLG surface. The deposited Pd NPs on the SLG surface were well-distributed with high uniformity and low defects. The Pd NP/SLG hybrid was then coated with polymer membrane layer for the selective filtration of H2. Because of the selective H2 filtration effect of the polymer membrane layer, the sensor had no responses to methane, carbon monoxide, or nitrogen dioxide gas. On the contrary, the PMMA/Pd NP/SLG hybrid sensor exhibited a good response to exposure to 2% H2: on average, 66.37% response within 1.81 min and recovery within 5.52 min. In addition, reliable and repeatable sensing behaviors were obtained when the sensor was exposed to different H2 concentrations ranging from 0.025 to 2%.
NASA Astrophysics Data System (ADS)
Kishore, Pabbisetti Vayu Nandana; Madhuvarasu, Sai Shankar; Moru, Satyanarayana
2018-01-01
This paper proposes a chemo-mechanical-optical sensing approach for the detection of carcinogenic chromium (VI) metal ion using an etched fiber Bragg grating (FBG) coated with stimulus responsive hydrogel. Hydrogel synthesized from the blends of (3-acrylamidopropyl)-trimethylammonium chloride, which is highly responsive to chromium ions suffers a volume change when placed in Cr solution. When the proposed sensor system is exposed to various concentrations of Cr (VI) ion solution, FBG peak shifts due to the mechanical strain induced by the swelling of the hydrogel. The peak shift is correlated with the concentration of the Cr (VI) metal ion. Due to the reduction in the cladding diameter of FBG, wastage of swelling force due to hydrogel on FBG is lowered and utilized for more wavelength peak shift of FBG resulting in the increase in the sensitivity. The resolution of the sensor system is found to be 0.072 ppb. Trace amounts of chromium (VI) ion as low as 10 ppb can be sensed by this method. The sensor has shown good sensitivity, selectivity, and repeatability. The salient features of the sensors are its compact size, light weight, and adoptability for remote monitoring.
Guan, Ben; Zang, Yong; Han, Xiaohui; Zheng, Kailun
2018-01-01
Driven by the demands for contactless stress detection, technologies are being used for shape control when producing cold-rolled strips. This paper presents a novel contactless stress detection technology based on a magnetoresistance sensor and the magnetoelastic effect, enabling the detection of internal stress in manufactured cold-rolled strips. An experimental device was designed and produced. Characteristics of this detection technology were investigated through experiments assisted by theoretical analysis. Theoretically, a linear correlation exists between the internal stress of strip steel and the voltage output of a magneto-resistive sensor. Therefore, for this stress detection system, the sensitivity of the stress detection was adjusted by adjusting the supply voltage of the magnetoresistance sensor, detection distance, and other relevant parameters. The stress detection experimental results showed that this detection system has good repeatability and linearity. The detection error was controlled within 1.5%. Moreover, the intrinsic factors of the detected strip steel, including thickness, carbon percentage, and crystal orientation, also affected the sensitivity of the detection system. The detection technology proposed in this research enables online contactless detection and meets the requirements for cold-rolled steel strips. PMID:29883387
Graphene-deposited photonic crystal fibers for continuous refractive index sensing applications.
Tan, Y C; Tou, Z Q; Chow, K K; Chan, C C
2015-11-30
We present a pilot demonstration of an optical fiber based refractive index (RI) sensor involving the deposition of graphene onto the surface of a segment of a photonic crystal fiber (PCF) in a fiber-based Mach-Zehnder Interferometer (MZI). The fabrication process is relatively simple and only involves the fusion splicing of a PCF between two single mode fibers. The deposition process relies only on the cold transfer of graphene onto the PCF segment, without the need for further physical or chemical treatment. The graphene overlay modified the sensing scheme of the MZI RI sensor, allowing the sensor to overcome limitations to its detectable RI range due to free spectral range issues. This modification also allows for continuous measurements to be obtained without the need for reference values for the range of RIs studied and brings to light the potential for simultaneous dual parameter sensing. The sensor was able to achieve a RI sensitivity of 9.4 dB/RIU for the RIs of 1.33-1.38 and a sensitivity of 17.5 dB/RIU for the RIs of 1.38-1.43. It also displayed good repeatability and the results obtained were consistent with the modeling.
Guan, Ben; Zang, Yong; Han, Xiaohui; Zheng, Kailun
2018-05-21
Driven by the demands for contactless stress detection, technologies are being used for shape control when producing cold-rolled strips. This paper presents a novel contactless stress detection technology based on a magnetoresistance sensor and the magnetoelastic effect, enabling the detection of internal stress in manufactured cold-rolled strips. An experimental device was designed and produced. Characteristics of this detection technology were investigated through experiments assisted by theoretical analysis. Theoretically, a linear correlation exists between the internal stress of strip steel and the voltage output of a magneto-resistive sensor. Therefore, for this stress detection system, the sensitivity of the stress detection was adjusted by adjusting the supply voltage of the magnetoresistance sensor, detection distance, and other relevant parameters. The stress detection experimental results showed that this detection system has good repeatability and linearity. The detection error was controlled within 1.5%. Moreover, the intrinsic factors of the detected strip steel, including thickness, carbon percentage, and crystal orientation, also affected the sensitivity of the detection system. The detection technology proposed in this research enables online contactless detection and meets the requirements for cold-rolled steel strips.
Kosmoliaptsis, Vasilios; Gjorgjimajkoska, Olivera; Sharples, Linda D; Chaudhry, Afzal N; Chatzizacharias, Nikolaos; Peacock, Sarah; Torpey, Nicholas; Bolton, Eleanor M; Taylor, Craig J; Bradley, J Andrew
2014-11-01
We have analyzed the relationship between donor mismatches at each HLA locus and development of HLA locus-specific antibodies in patients listed for repeat transplantation. HLA antibody screening was undertaken using single-antigen beads in 131 kidney transplant recipients returning to the transplant waiting list following first graft failure. The number of HLA mismatches and the calculated reaction frequency of antibody reactivity against 10,000 consecutive deceased organ donors were determined for each HLA locus. Two-thirds of patients awaiting repeat transplantation were sensitized (calculated reaction frequency over 15%) and half were highly sensitized (calculated reaction frequency of 85% and greater). Antibody levels peaked after re-listing for repeat transplantation, were independent of graft nephrectomy and were associated with length of time on the waiting list (odds ratio 8.4) and with maintenance on dual immunosuppression (odds ratio 0.2). Sensitization was independently associated with increasing number of donor HLA mismatches (odds ratio 1.4). All mismatched HLA loci contributed to the development of HLA locus-specific antibodies (HLA-A: odds ratio 3.2, HLA-B: odds ratio 3.4, HLA-C: odds ratio 2.5, HLA-DRB1: odds ratio 3.5, HLA-DRB3/4/5: odds ratio 3.9, and HLA-DQ: odds ratio 3.0 (all significant)). Thus, the risk of allosensitization following failure of a first renal transplant increases incrementally with the number of mismatches at all HLA loci assessed. Maintenance of re-listed patients on dual immunosuppression was associated with a reduced risk of sensitization.
Daviu, Núria; Rabasa, Cristina; Nadal, Roser; Armario, Antonio
2014-03-01
Acute exposure to severe stressors causes marked activation of the hypothalamic-pituitary-adrenal (HPA) axis that is reflected on the day after higher resting levels of HPA hormones and sensitization of the HPA response to novel (heterotypic) stressors. However, whether a single exposure to a severe stressor or daily repeated exposure to the same (homotypic) stressor modifies these responses to the same extent has not been studied. In this experiment, we studied this issue in adult male Sprague-Dawley rats daily exposed for seven days to a severe stressor such as immobilization on boards (IMO). A first exposure to 1 h IMO resulted in a marked activation of the HPA axis as reflected in plasma levels of adrenocorticotropic hormone (ACTH) and corticosterone, and such activation was significantly reduced after the seventh IMO. On the day after the first IMO, higher resting levels of ACTH and corticosterone and sensitization of their responses to a short exposure to an open-field (OF) were observed, together with a marked hypoactivity in this environment. Repeated exposure to IMO partially reduced hypoactivity, the increase in resting levels of HPA hormones and the ACTH responsiveness to the OF on the day after the last exposure to IMO. In contrast, corticosterone response was gradually increased, suggesting partial dissociation from ACTH. These results indicate that daily repeated exposure to the same stressor partially reduced the HPA response to the homotypic stressor as well as the sensitization of HPA axis activity observed the day after chronic stress cessation.
Majidi, Mir Reza; Ghaderi, Seyran
2017-12-01
High surface area nanoporous Cu film (NPCF) has been successfully synthesized using a hydrogen bubble dynamic template on the graphene nanosheets (GNs) modified glassy carbon electrode (GCE). The effect of different synthesis conditions such as applied potential and deposition time on the NPCF morphology was investigated. The structure and constituent of the NPCF-GNs/GCE were characterized by scanning electron microscopy (SEM), energy-dispersive x-ray (EDX), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and electrochemical methods. The study on electrocatalytic performance of the NPCF-GNs/GCE demonstrated that this electrode has excellent catalytic activity toward nitrite oxidation. The quantitative measurement of nitrite by amperometric method showed a wide concentration range (0.1-100µmolL -1 ) with a detection limit and a sensitivity of 8.87 × 10 -8 molL -1 and 3.1 AL/molcm 2 , respectively. The excellent electrochemical response and high sensitivity of the proposed electrode were attributed to the 3D structure of NPCF and the synergic effect of NPCF and GNs. Furthermore, this electrode showed some other advantages including good repeatability, high reproducibility, long-term stability and anti-interference performance toward nitrite sensing. The applicability of the proposed electrode was proved by successful determination of nitrite in real samples (tap water, river water and sausage samples). Copyright © 2017 Elsevier B.V. All rights reserved.
Zabardasti, Abedin; Afrouzi, Hossein; Talemi, Rasoul Pourtaghavi
2017-07-01
In this work, we have prepared a nano-material modified pencil graphite electrode for the sensing of valproic acid (VA) by immobilization 3-aminopropyletriethoxy silane coated magnetic nanoparticles (APTES-MNPs) on the pencil graphite surface (PGE). Electrochemical studies indicated that the APTES-MNPs efficiently increased the electron transfer kinetics between VA and the electrode and the free NH 2 groups of the APTES on the outer surface of magnetic nanoparticles can interact with carboxyl groups of VA. Based on this, we have proposed a sensitive, rapid and convenient electrochemical method for VA determination. Under the optimized conditions, the reduction peak current of VA is found to be proportional to its concentration in the range of 1.0 (±0.2) to 100.0 (±0.3) ppm with a detection limit of 0.4 (±0.1) ppm. The whole sensor fabrication process was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods with using [Fe(CN) 6 ] 3-/4- as an electrochemical redox indicator. The prepared modified electrode showed several advantages such as high sensitivity, selectivity, ease of preparation and good repeatability, reproducibility and stability. The proposed method was applied to determination of valproic acid in blood plasma samples and the obtained results were satisfactory accurate. Copyright © 2017. Published by Elsevier B.V.
Liang, X; Wang, Z-Y; Liu, H-Y; Lin, Q; Wang, Z; Liu, Y
2015-01-01
to investigate adult attachment status in first-time mothers, and stability and/or changes in maternal sensitivity during infancy. longitudinal study using quantitative and qualitative methods, and statistical modelling. Three home visits were undertaken when the infant was approximately six, nine and 14 months old. The Adult-to-Parental Attachment Experience Survey was used, and scores for three dimensions were obtained: secure-autonomous, preoccupied and dismissive. Maternal sensitivity was assessed at each time point using the Maternal Behaviour Q-Sort by observing interaction between the mother and infant at home. homes and community settings in greater metropolitan Beijing, North China. 83 mothers and infants born in 2010 enrolled in this study. Data were missing for one or more time points in 20 cases. the mean score for maternal sensitivity tended to increase from six to 14 months. Post-hoc analyses of one-way repeated-measures analysis of variance revealed that maternal sensitivity was significantly higher at 14 months than at six or nine months. An unconditional latent growth model (LGM) of maternal sensitivity, estimated using the Bayesian approach, provided a good fit for the data. Using three attachment-related variables as predictors in the conditional LGM, the model fitting indices were found to be sufficient, and the results suggested that the secure score positively predicted the intercept of the growth model, and the dismissive score negatively predicted both the intercept and slope of the growth model. maternal sensitivity increased over time during infancy. Furthermore, individual differences existed in the developmental trajectory, which was influenced by maternal attachment status. knowledge about attachment-related differences in the trajectory of first-time mothers' sensitivity to infants may help midwives and doctors to provide individualised information and support, with special attention given to mothers with a dismissive attachment status. Copyright © 2014 Elsevier Ltd. All rights reserved.
Schuster-Gossler, Karin; Cordes, Ralf; Müller, Julia; Geffers, Insa; Delany-Heiken, Patricia; Taft, Manuel; Preller, Matthias; Gossler, Achim
2016-01-01
The highly conserved Notch-signaling pathway mediates cell-to-cell communication and is pivotal for multiple developmental processes and tissue homeostasis in adult organisms. Notch receptors and their ligands are transmembrane proteins with multiple epidermal-growth-factor-like (EGF) repeats in their extracellular domains. In vitro the EGF repeats of mammalian ligands that are essential for Notch activation have been defined. However, in vivo the significance of the structural integrity of each EGF repeat in the ligand ectodomain for ligand function is still unclear. Here, we analyzed the mouse Notch ligand DLL1. We expressed DLL1 proteins with mutations disrupting disulfide bridges in each individual EGF repeat from single-copy transgenes in the HPRT locus of embryonic stem cells. In Notch transactivation assays all mutations impinged on DLL1 function and affected both NOTCH1 and NOTCH2 receptors similarly. An allelic series in mice that carried the same point mutations in endogenous Dll1, generated using a mini-gene strategy, showed that early developmental processes depending on DLL1-mediated NOTCH activation were differently sensitive to mutation of individual EGF repeats in DLL1. Notably, some mutations affected only somite patterning and resulted in vertebral column defects resembling spondylocostal dysostosis. In conclusion, the structural integrity of each individual EGF repeat in the extracellular domain of DLL1 is necessary for full DLL1 activity, and certain mutations in Dll1 might contribute to spondylocostal dysostosis in humans. PMID:26801181
Evolution of All-or-None Strategies in Repeated Public Goods Dilemmas
2014-01-01
Many problems of cooperation involve repeated interactions among the same groups of individuals. When collective action is at stake, groups often engage in Public Goods Games (PGG), where individuals contribute (or not) to a common pool, subsequently sharing the resources. Such scenarios of repeated group interactions materialize situations in which direct reciprocation to groups may be at work. Here we study direct group reciprocity considering the complete set of reactive strategies, where individuals behave conditionally on what they observed in the previous round. We study both analytically and by computer simulations the evolutionary dynamics encompassing this extensive strategy space, witnessing the emergence of a surprisingly simple strategy that we call All-Or-None (AoN). AoN consists in cooperating only after a round of unanimous group behavior (cooperation or defection), and proves robust in the presence of errors, thus fostering cooperation in a wide range of group sizes. The principles encapsulated in this strategy share a level of complexity reminiscent of that found already in 2-person games under direct and indirect reciprocity, reducing, in fact, to the well-known Win-Stay-Lose-Shift strategy in the limit of the repeated 2-person Prisoner's Dilemma. PMID:25393661
Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz
2017-01-01
Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017
Sensitivity to bites by the bedbug, Cimex lectularius.
Reinhardt, K; Kempke, D; Naylor, R A; Siva-Jothy, M T
2009-06-01
Bedbugs are a public health problem and can cause significant economic losses, but little is known about the effects of bites on humans. We reviewed case reports and published papers on bedbug bites to assess the empirical basis of the commonly cited figure that only approximately 80% of the population are sensitive to bedbug bites. We found the sensitivity estimate to be based on only one study carried out 80 years ago. However, this study did not account for the now well-established fact that only repeated exposure to external allergens leads to skin reactions. In our sample, 18 of 19 persons showed a skin reaction after bedbug exposure, but in most cases only after repeated controlled exposure. With repeated exposure, the latency between bite and skin reactions decreased from approximately 10 days to a few seconds. Our results are relevant for the hospitality industry, where apparently increasing infestation rates are likely to lead to an increase in the number of tourists and hotel employees exposed to bedbugs. Medical and public health professionals may expect to see an increase in the prevalence of people with bedbug bite sensitivity. The significance of the delayed reaction time of skin to bites may also have implications in litigation cases where people seek compensation.
Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi
2016-01-01
We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318
Zhao, Zheng Lin; Kim, Sang Chan; Liu, Hong Feng; Wu, Yi Yan; Li, Li Bo; Wang, Yu Hua; Jiao, Yu; Fan, Yu; Lee, Chul Won; Lee, Bong Hyeo; Cho, Il Je; Yang, Chae Ha; Zhao, Rong Jie
2017-11-16
We previously reported that a methanol extract of Glycyrrhizae radix (MEGR) blocked methamphetamine-induced locomotor sensitization and conditioned place preference in rats. In the present study, the effects of MEGR on repeated nicotine-induced locomotor sensitization and enhanced extracellular dopamine (DA) release in the nucleus accumbens (Nacc) were evaluated. Male Sprague-Dawley rats received repeated administrations of nicotine (0.4 mg/kg, subcutaneous) or saline twice a day for 7 d and were challenged with nicotine 4 d after the last daily dosing. During the 4-d withdrawal period, the rats were treated once a day with MEGR (60 or 180 mg/kg/d). Extracellular DA levels were measured by in vivo microdialysis, the malondialdehyde levels and the activities of superoxide dismutase and catalase in the Nacc were biochemically evaluated, and the expression of antioxidant proteins was confirmed by Western blot assays. All data were assessed with analysis of variance tests followed by post-hoc comparison tests and p values <0.05 were considered statistically significant. The expression of repeated nicotine-induced locomotor sensitization was dose-dependently attenuated by MEGR, and 180 mg/kg/d MEGR significantly inhibited augmented accumbal DA release induced by a direct local challenge of nicotine. Moreover, 180 mg/kg/d MEGR reversed increases in malondialdehyde production, decreases in superoxide dismutase and catalase activities, and the reduced expression of nuclear factor erythroid 2-related factor 2 and heme oxygenase 1 in the nicotine-sensitized Nacc. These results suggest that MEGR inhibited nicotine-induced locomotion and dopaminergic sensitization via antioxidant action.
Fu, Zhenyu; Yang, Hongfa; Xiao, Yuqiang; Zhao, Gang; Huang, Haiyan
2012-07-10
Repeated morphine exposure can induce behavioral sensitization. There are evidences have shown that central gamma-aminobutyric acid (GABA) system is involved in morphine dependence. However, the effect of a GABAB receptor agonist baclofen on morphine-induced behavioral sensitization in rats is unclear. We used morphine-induced behavioral sensitization model in rat to investigate the effects of baclofen on behavioral sensitization. Moreover, dopamine release in the shell of the nucleus accumbens was evaluated using microdialysis assay in vivo. The present study demonstrated that morphine challenge (3 mg/kg, s.c.) obviously enhanced the locomotor activity following 4-day consecutive morphine administration and 3-day withdrawal period, which indicated the expression of morphine sensitization. In addition, chronic treatment with baclofen (2.5, 5 mg/kg) significantly inhibited the development of morphine sensitization. It was also found that morphine challenge 3 days after repeated morphine administration produced a significant increase of extracellular dopamine release in nucleus accumbens. Furthermore, chronic treatment with baclofen decreased the dopamine release induced by morphine challenge. Our results indicated that gamma-aminobutyric acid system plays an important role in the morphine sensitization in rat and suggested that behavioral sensitization is a promising model to study the mechanism underlying drug abuse.
Lopez, M. F.; Becker, H. C.; Chandler, L. J.
2014-01-01
Studies in animal models have shown that repeated episodes of alcohol dependence and withdrawal promote escalation of drinking that is presumably associated with alterations in the addiction neurocircuitry. Using a lithium chloride-ethanol pairing procedure to devalue the reinforcing properties of ethanol, the present study determined whether multiple cycles of chronic intermittent ethanol (CIE) exposure by vapor inhalation also alters the sensitivity of drinking behavior to the devaluation of ethanol's reinforcing effects. The effect of devaluation on operant ethanol self-administration and extinction was examined in mice prior to initiation of CIE (short drinking history) and after repeated cycles of CIE or air control exposure (long drinking history). Devaluation significantly attenuated the recovery of baseline ethanol self-administration when tested either prior to CIE or in the air-exposed controls that had experienced repeated bouts of drinking but no CIE. In contrast, in mice that had undergone repeated cycles of CIE exposure that promoted escalation of ethanol drinking, self-administration was completely resistant to the effect of devaluation. Devaluation had no effect on the time course of extinction training in either pre-CIE or post-CIE mice. Taken together, these results are consistent with the suggestion that repeated cycles of ethanol dependence and withdrawal produce escalation of ethanol self-administration that is associated with a change in sensitivity to devaluation of the reinforcing properties of ethanol. PMID:25266936
Aapro, M. S.; Kirchner, V.; Terrey, J. P.
1994-01-01
Anticipatory nausea and vomiting (ANV) after repeated cycles of cytotoxic chemotherapy is thought to be a conditioned response to a conditioning stimulus. Good control of acute and delayed emesis may result in a lower incidence of ANV. We have analysed data from 574 chemotherapy patients who received granisetron as their antiemetic treatment during repeat cycle chemotherapy. Per treatment cycle, less than 10% of patients displayed symptoms of anticipatory nausea and 2% or less had symptoms of anticipatory vomiting. It is concluded that the use of granisetron as an antiemetic during the acute phase of chemotherapy may result in a lower incidence of ANV in patients undergoing repeat cycle chemotherapy. PMID:8180031
Cooper, Dale J; Scammell, Brigitte E; Batt, Mark E; Palmer, Debbie
2018-01-17
The impracticalities and comparative expense of carrying out a clinical assessment is an obstacle in many large epidemiological studies. The purpose of this study was to develop and validate a series of electronic self-reported line drawing instruments based on the modified Beighton scoring system for the assessment of self-reported generalised joint hypermobility. Five sets of line drawings were created to depict the 9-point Beighton score criteria. Each instrument consisted of an explanatory question whereby participants were asked to select the line drawing which best represented their joints. Fifty participants completed the self-report online instrument on two occasions, before attending a clinical assessment. A blinded expert clinical observer then assessed participants' on two occasions, using a standardised goniometry measurement protocol. Validity of the instrument was assessed by participant-observer agreement and reliability by participant repeatability and observer repeatability using unweighted Cohen's kappa (k). Validity and reliability were assessed for each item in the self-reported instrument separately, and for the sum of the total scores. An aggregate score for generalised joint hypermobility was determined based on a Beighton score of 4 or more out of 9. Observer-repeatability between the two clinical assessments demonstrated perfect agreement (k 1.00; 95% CI 1.00, 1.00). Self-reported participant-repeatability was lower but it was still excellent (k 0.91; 95% CI 0.74, 1.00). The participant-observer agreement was excellent (k 0.96; 95% CI 0.87, 1.00). Validity was excellent for the self-report instrument, with a good sensitivity of 0.87 (95% CI 0.81, 0.91) and excellent specificity of 0.99 (95% CI 0.98, 1.00). The self-reported instrument provides a valid and reliable assessment of the presence of generalised joint hypermobility and may have practical use in epidemiological studies.
Kageyama, N; Ichinose, M; Igarashi, A; Miura, M; Yamauchi, H; Sasaki, Y; Ishikawa, J; Tomaki, M; Shirato, K
1996-07-01
The effect of repeated allergen inhalation challenge on the airway excitatory nonadrenergic noncholinergic (e-NANC) nerve-mediated bronchoconstrictor response was studied in ovalbumin (OA) sensitized guinea-pigs. Three weeks after sensitization, OA inhalation, 0.03% for 3 min (challenged group), or saline inhalation (control group) was repeated every day for 4 weeks. The e-NANC nerve function was examined in vitro by means of isometric tension measurement of main bronchi. After pretreatment with atropine (10(-6) M) and propranolol (10(-6) M), we performed electrical field stimulation (EFS) or exogenous neurokinin A (NKA) administration. In the challenged group, EFS-induced main bronchial contraction was significantly greater than that of the control group (p < 0.05 or p < 0.01), but exogenous NKA-mediated responses were almost the same in both groups. The e-NANC-induced main bronchial contractions after EFS were enhanced by pretreatment with the neutral endopeptidase inhibitor, phosphoramidon, to the same degree in the control and challenged groups, indicating that the peptide degradation mechanisms were not impaired even in the challenged group. Substance P immunoreactivities in the lung of the challenged group were significantly higher than those of the control group. These results suggest that chronic airway inflammation after repeated allergen challenge increases excitatory nonadrenergic noncholinergic nerve function, possibly by enhancing sensory neuropeptide production and/or release.
Competitive Bidding in a Certain Class of Auctions
NASA Astrophysics Data System (ADS)
Johansson, Mathias
2006-11-01
We consider the problem of determining the amount to bid in a certain type of auctions in which customers submit one sealed bid. The bid reflects the price a customer is willing to pay for one unit of the offered goods. The auction is repeated and at each auction each customer requests a certain amount of goods, an amount that we call the capacity of the customer and that varies among customers and over time. At each auction, only the customer with the largest bid-capacity product obtains any goods. The price paid by the winner equals his/her bid-capacity product, and the amount of goods obtained in return equals the winner's capacity. The auction is repeated many times, with only limited information concerning winning bid-capacity products being announced to the customers. This situation is motivated in for example wireless communication networks in which a possible way of obtaining a desired service level is to use dynamic pricing and competitive bidding. In this application, the capacity is typically uncertain when the bid is made. We derive bidding rules and loss functions for a few typical service requirements.
Kelsey, John E; Gerety, Lyle P; Guerriero, Rejean M
2009-06-01
We previously demonstrated that lesions of the nucleus accumbens (NAc) core enhanced locomotion and locomotor sensitization to repeated injections of nicotine in rats (Kelsey & Willmore, 2006). In this study, we compared the effects of separate lesions of the NAc core, NAc medial shell, and basolateral amygdala on context-specific locomotor sensitization to repeated injections of 0.4 mg/kg nicotine. Electrolytic lesions of the NAc core increased locomotion, and lesions of the core (but not the shell) and the basolateral amygdala enhanced context-specific locomotor sensitization by enhancing the development of sensitization in paired rats and decreasing expression in unpaired rats relative to sham-operated rats when challenged with an injection of 0.4 mg/kg nicotine in the locomotor chambers. These data are consistent with findings that the NAc core and the basolateral amygdala share a variety of behavioral functions and anatomical connections. The findings that lesions of these structures enhance context-specific locomotor sensitization while typically impairing other reward-related behaviors also indicate that the processes underlying locomotor sensitization and reward are not identical. Copyright (c) 2009 APA, all rights reserved.
Liu, Yan-Jun; Cao, Wen-Tao; Ma, Ming-Guo; Wan, Pengbo
2017-08-02
Robust, stretchable, and strain-sensitive hydrogels have recently attracted immense research interest because of their potential application in wearable strain sensors. The integration of the synergistic characteristics of decent mechanical properties, reliable self-healing capability, and high sensing sensitivity for fabricating conductive, elastic, self-healing, and strain-sensitive hydrogels is still a great challenge. Inspired by the mechanically excellent and self-healing biological soft tissues with hierarchical network structures, herein, functional network hydrogels are fabricated by the interconnection between a "soft" homogeneous polymer network and a "hard" dynamic ferric (Fe 3+ ) cross-linked cellulose nanocrystals (CNCs-Fe 3+ ) network. Under stress, the dynamic CNCs-Fe 3+ coordination bonds act as sacrificial bonds to efficiently dissipate energy, while the homogeneous polymer network leads to a smooth stress-transfer, which enables the hydrogels to achieve unusual mechanical properties, such as excellent mechanical strength, robust toughness, and stretchability, as well as good self-recovery property. The hydrogels demonstrate autonomously self-healing capability in only 5 min without the need of any stimuli or healing agents, ascribing to the reorganization of CNCs and Fe 3+ via ionic coordination. Furthermore, the resulted hydrogels display tunable electromechanical behavior with sensitive, stable, and repeatable variations in resistance upon mechanical deformations. Based on the tunable electromechanical behavior, the hydrogels can act as a wearable strain sensor to monitor finger joint motions, breathing, and even the slight blood pulse. This strategy of building synergistic "soft and hard" structures is successful to integrate the decent mechanical properties, reliable self-healing capability, and high sensing sensitivity together for assembling a high-performance, flexible, and wearable strain sensor.
Li, Ming; Lu, Fan
2017-01-01
Objectives To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P < 0.05). Conclusions The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min. PMID:28751981
Repeated human leukocyte antigen mismatches in lung re-transplantation.
Sommer, Wiebke; Hallensleben, Michael; Ius, Fabio; Kühn, Christian; Tudorache, Igor; Avsar, Murat; Salman, Jawad; Siemeni, Thierry; Greer, Mark; Gottlieb, Jens; Boethig, Dietmar; Blasczyk, Rainer; Haverich, Axel; Warnecke, Gregor
2017-02-01
The role of HLA-sensitization in the absence of detectable DSA in lung re-transplantation is unclear. Antigens of the second donor matching the HLA typing of the first donor are considered 'unacceptable', by some tissue typing laboratories, especially in kidney re-transplantation. Thus, we performed a retrospective analysis of all lung re-transplantations focussing on the impact of HLA-homologies between the first and the second donor ('unacceptable' antigens; repeated HLA mismatch) on patient and graft survival. A total of 132 lung re-transplantations were performed at our centre between 1985 and 2014, of which 120 with complete HLA data were analysed. 55.8% of the recipients received re-transplants with repeated HLA mismatched antigens whereas 43.2% of the re-transplants were transplanted without repeated HLA mismatched antigens. Postoperative survival showed no difference between re-transplant procedures with or without repeated HLA mismatches (p=0.99). While neither homologies on the HLA-A, -B, -C, or -DR locus, nor the addition of several locus homologies (p=0.72) had an impact on survival, unexpectedly, repeated HLA mismatching on the HLA-DQ locus was correlated with better survival. Re-transplantations with repeated HLA mismatches did not result in more development of CLAD as compared to recipients without repeated HLA mismatches (p=0.99). Neither the number of repeated HLA mismatched antigens (p=0.52) nor the HLA locus (HLA-A(p=0.34), HLA-B(p=0.97), HLA-C (p=0.80), HLA-DR(p=0.49) and HLA-DQ(p=0.07)) had an impact on the development of CLAD after re-transplantation. Transplantation with repeated HLA mismatches due to sensitization by a previous transplantation in the absence of detectable HLA-antibodies does not have a negative impact on patient or graft survival. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Holland, A. A.; Ringler, A. T.; Wilson, D.
2016-12-01
We attempt to estimate lower bounds on the repeatability for a number of common instrumentation parameters and provide estimates on the errors associated with the instrument installation itself. These parameters include the self-noise, the orientation, and the sensitivity. We installed three Trillium Compact instruments within 30 cm of each other in the same seismic vault at the Albuquerque Seismological Laboratory. We then repeatedly uninstall and reinstall one of the Trillium Compact instruments multiple times, while leaving the other two in place as reference installations. Using these trials we are then able to examine how repeatable several parameters are between the two reference instruments and the other instrument. We also completely uninstalled and reinstalled the three seismometers once during the testing, in order to examine the reproducibility of the entire experiment. Results indicate that relative sensitivity is highly repeatable, which is partly why we chose this particular sensor for this evaluation. We find that self-noise in the band of 0.1 to 30 s period of an instrument is repeatable to within about 2 dB. Increasing the period of interest from 30 to 100 s period we observe that the self-noise of an instrument can only be repeated to within about 3 dB and that the relative self-noise is not repeatable amongst the sensors. We also find that even though the seismometers are centimeters apart on a single marked line, that the relative orientation between installations is only repeatable to within 1-2 degrees. However, the relative orientations are reproducible, that is, with each installation the relative orientations are within the same amount of uncertainty. Some other broadband or very broadband instruments may not show as much repeatability between installations for some of the metrics we examined. From these tests we can say that instrument self-noise tests are reproducible to within a few dB.
Context-Dependent Repetition Effects on Recognition Memory
ERIC Educational Resources Information Center
Opitz, Bertram
2010-01-01
One widely acknowledged way to improve our memory performance is to repeatedly study the to be learned material. One aspect that has received little attention in past research regards the context sensitivity of this repetition effect, that is whether the item is repeated within the same or within different contexts. The predictions of a…
Performance feedback, self-esteem, and cardiovascular adaptation to recurring stressors.
Brown, Eoin G; Creaven, Ann-Marie
2017-05-01
This study sought to examine the effects of performance feedback and individual differences in self-esteem on cardiovascular habituation to repeat stress exposure. Sixty-six university students (n = 39 female) completed a self-esteem measure and completed a cardiovascular stress-testing protocol involving repeated exposure to a mental arithmetic task. Cardiovascular functioning was sampled across four phases: resting baseline, initial stress exposure, a recovery period, and repeated stress exposure. Participants were randomly assigned to receive fictional positive feedback, negative feedback, or no feedback following the recovery period. Negative feedback was associated with a sensitized blood pressure response to a second exposure of the stress task. Positive feedback was associated with decreased cardiovascular and psychological responses to a second exposure. Self-esteem was also found to predict reactivity and this interacted with the type of feedback received. These findings suggest that negative performance feedback sensitizes cardiovascular reactivity to stress, whereas positive performance feedback increases both cardiovascular and psychological habituation to repeat exposure to stressors. Furthermore, an individual's self-esteem also appears to influence this process.
Simulated Keratometry Repeatability in Subjects with & without Down Syndrome
Ravikumar, Ayeswarya; Marsack, Jason D.; Benoit, Julia S.; Anderson, Heather A.
2016-01-01
Purpose To assess the repeatability of simulated keratometry measures obtained with Zeiss Atlas topography for subjects with and without Down syndrome (DS). Methods Corneal topography was attempted on 140 subjects with DS and 138 controls (aged 7 to 59 years). Subjects who had at least 3 measures in each eye were included in analysis (DS: n=140 eyes (70 subjects) and controls: n=264 eyes (132 subjects)). For each measurement the steep corneal power (K), corneal astigmatism, flat K orientation, power vector representation of astigmatism (J0, J45), and astigmatic dioptric difference were determined for each measurement (collectively termed keratometry values here). For flat K orientation comparisons, only eyes with >0.50 DC of astigmatism were included (DS: n=131 eyes (68 subjects) and control: n=217 eyes (119 subjects)). Repeatability was assessed using 1) group mean variability (average standard deviation (SD) across subjects), 2) coefficient of repeatability (COR) 3) coefficient of variation (COV), and 4) intraclass correlation coefficient (ICC). Results The keratometry values showed good repeatability as evidenced by low group mean variability for DS vs control eyes (≤0.26D vs ≤0.09D for all dioptric values; 4.51° vs 3.16° for flat K orientation); however, the group mean variability was significantly higher in DS eyes than control eyes for all parameters (p≤0.03). On average, group mean variability was 2.5× greater in the DS eyes compared to control eyes across the keratometry values. Other metrics of repeatability also indicated good repeatability for both populations for each keratometry value, although repeatability was always better in the control eyes. Conclusions DS eyes showed more variability (on average: 2.5×) compared to controls for all keratometry values. Although differences were statistically significant, on average 91% of DS eyes had variability ≤0.50D for steep K and astigmatism, and 75% of DS eyes had variability ≤5 degrees for flat K orientation. PMID:27741083
Interactions of Stress and CRF in Ethanol-Withdrawal Induced Anxiety in Adolescent and Adult Rats
Wills, Tiffany A.; Knapp, Darin J.; Overstreet, David H.; Breese, George R.
2010-01-01
Background Repeated stress or administration of corticotropin-releasing factor (CRF) prior to ethanol exposure sensitizes anxiety-like behavior in adult rats. Current experiments determined whether adolescent rats were more sensitive to these challenges in sensitizing ethanol withdrawal-induced anxiety and altering CRF levels in brain during withdrawal. Methods Male adult and adolescent Sprague–Dawley rats were restraint stressed (1 hour) twice 1 week apart prior to a single 5-day cycle of ethanol diet (ED; stress/withdrawal paradigm). Other rats received control diet (CD) and three 1-hour restraint stress sessions. Rats were then tested 5, 24, or 48 hours after the final withdrawal for anxiety-like behavior in the social interaction (SI) test. In other experiments, adolescent rats were given two microinjections of CRF icv 1 week apart followed by 5-days of either CD or ED and tested in social interaction 5 hours into withdrawal. Finally, CRF immunoreactivity was measured in the central nucleus of the amygdala (CeA) and paraventricular nucleus (PVN) after rats experienced control diet, repeated ethanol withdrawals, or stress/withdrawal. Results Rats of both ages had reduced SI following the stress/withdrawal paradigm, and this effect recovered within 24 hours. Higher CRF doses were required to reduce SI in adolescents than previously reported in adults. CRF immunohistochemical levels were higher in the PVN and CeA of CD-exposed adolescents. In adolescent rats, repeated ethanol withdrawals decreased CRF in the CeA but was not associated with decreased CRF cell number. There was no change in CRF from adult treatments. Conclusions In the production of anxiety-like behavior, adolescent rats have equal sensitivity with stress and lower sensitivity with CRF compared to adults. Further, adolescents had higher basal levels of CRF within the PVN and CeA and reduced CRF levels following repeated ethanol withdrawals. This reduced CRF within the CeA could indicate increased release of CRF, and future work will determine how this change relates to behavior. PMID:20586753
Ronco, Guglielmo; Zappa, Marco; Franceschi, Silvia; Tunesi, Sara; Caprioglio, Adele; Confortini, Massimo; Del Mistro, Annarosa; Carozzi, Francesca; Segnan, Nereo; Zorzi, Manuel; Giorgi-Rossi, Paolo
2016-11-01
Women positive to human papillomavirus (HPV+) testing at cervical screening need triage, typically cytology and immediate colposcopy in case of atypical squamous cells of undetermined significance (ASCUS) or worse (ASCUS+) or, in cytology-normal HPV+ women, HPV test repeat after 1 year and colposcopy referral if still HPV+. Our hypothesis was that substantial variations in triage positivity and sensitivity may produce little variation in overall referral to colposcopy and on sensitivity of the entire screening process. Centre- and age-aggregated data from 72,869 women aged 35-64 years were derived from 10 organised screening programmes which have piloted HPV screening in Italy since 2012. Overall colposcopy referral was evaluated as a function of immediate colposcopy referral and overall CIN2+ detection as a function of the proportion of all CIN2+ detected by immediate referral (a proxy of cytology's sensitivity). We fitted additive regression models, adjusted for centre, age, compliance to HPV retesting and to colposcopy, by generalised estimation equations. The proportion of HPV+ women directly referred to colposcopy varied across programmes (20-57%; average 37%) and so did CIN2+ detection (49-94%; average 77%). Overall, 63% (range 41-75%) of HPV+ were referred to colposcopy either immediately or at HPV repeat. An absolute 10% increase in immediate colposcopy referral resulted in 4.2% (95% CI: 3.3-5.1%) increase in overall referral. An absolute 10% increase in cytology's sensitivity resulted in a 1.1% (95% CI: 0.1-2.0%) increase in overall CIN2+ detection. Repeat HPV testing limits the effect of subjectivity of cytology interpretation on overall referral and sensitivity. These will change only slightly when replacing cytology with another test if the interval to HPV repeat remains unchanged. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
VFMA: Topographic Analysis of Sensitivity Data From Full-Field Static Perimetry
Weleber, Richard G.; Smith, Travis B.; Peters, Dawn; Chegarnov, Elvira N.; Gillespie, Scott P.; Francis, Peter J.; Gardiner, Stuart K.; Paetzold, Jens; Dietzsch, Janko; Schiefer, Ulrich; Johnson, Chris A.
2015-01-01
Purpose: To analyze static visual field sensitivity with topographic models of the hill of vision (HOV), and to characterize several visual function indices derived from the HOV volume. Methods: A software application, Visual Field Modeling and Analysis (VFMA), was developed for static perimetry data visualization and analysis. Three-dimensional HOV models were generated for 16 healthy subjects and 82 retinitis pigmentosa patients. Volumetric visual function indices, which are measures of quantity and comparable regardless of perimeter test pattern, were investigated. Cross-validation, reliability, and cross-sectional analyses were performed to assess this methodology and compare the volumetric indices to conventional mean sensitivity and mean deviation. Floor effects were evaluated by computer simulation. Results: Cross-validation yielded an overall R2 of 0.68 and index of agreement of 0.89, which were consistent among subject groups, indicating good accuracy. Volumetric and conventional indices were comparable in terms of test–retest variability and discriminability among subject groups. Simulated floor effects did not negatively impact the repeatability of any index, but large floor changes altered the discriminability for regional volumetric indices. Conclusions: VFMA is an effective tool for clinical and research analyses of static perimetry data. Topographic models of the HOV aid the visualization of field defects, and topographically derived indices quantify the magnitude and extent of visual field sensitivity. Translational Relevance: VFMA assists with the interpretation of visual field data from any perimetric device and any test location pattern. Topographic models and volumetric indices are suitable for diagnosis, monitoring of field loss, patient counseling, and endpoints in therapeutic trials. PMID:25938002
de Matos, Liana Wermelinger; Carey, Robert J; Carrera, Marinete Pinheiro
2010-09-01
Repeated treatments with psychostimulant drugs generate behavioral sensitization. In the present study we employed a paired/unpaired protocol to assess the effects of repeated apomorphine (2.0 mg/kg) treatments upon locomotion behavior. In the first experiment we assessed the effects of conditioning upon apomorphine sensitization. Neither the extinction of the conditioned response nor a counter-conditioning procedure in which we paired an inhibitory treatment (apomorphine 0.05 mg/kg) with the previously established conditioned stimulus modified the sensitization response. In the second experiment, we administered the paired/unpaired protocol in two phases. In the second phase, we reversed the paired/unpaired protocol. Following the first phase, the paired group alone exhibited conditioned locomotion in the vehicle test and a sensitization response. In the second phase, the initial unpaired group which received 5 paired apomorphine trials during the reversal phase did not develop a conditioned response but developed a potentiated sensitization response. This disassociation of the conditioned response from the sensitization response is attributed to an apomorphine anti-habituation effect that can generate a false positive Pavlovian conditioned response effect. The potentiated sensitization response induced by the treatment reversal protocol points to an important role for the sequential experience of the paired/unpaired protocol in behavioral sensitization. 2010 Elsevier Inc. All rights reserved.
A discourse on sensitivity analysis for discretely-modeled structures
NASA Technical Reports Server (NTRS)
Adelman, Howard M.; Haftka, Raphael T.
1991-01-01
A descriptive review is presented of the most recent methods for performing sensitivity analysis of the structural behavior of discretely-modeled systems. The methods are generally but not exclusively aimed at finite element modeled structures. Topics included are: selections of finite difference step sizes; special consideration for finite difference sensitivity of iteratively-solved response problems; first and second derivatives of static structural response; sensitivity of stresses; nonlinear static response sensitivity; eigenvalue and eigenvector sensitivities for both distinct and repeated eigenvalues; and sensitivity of transient response for both linear and nonlinear structural response.
Wang, ShuLing; Xu, Hui
2016-12-01
An inorganic-organic hybrid nanocomposite (zinc oxide/polypyrrole) that represents a novel kind of coating for in-tube solid-phase microextraction is reported. The composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless-steel tube. Based on the coated tube, a novel online in-tube solid-phase microextraction with liquid chromatography and mass spectrometry method was developed and applied for the extraction of three monohydroxy polycyclic aromatic hydrocarbons in human urine. The coating displayed good extraction ability toward monohydroxy polycyclic aromatic hydrocarbons. In addition, long lifespan, excellent stability, and good compression resistance were also obtained for the coating. The experimental conditions affecting the extraction were optimized systematically. Under the optimal conditions, the limits of detection and quantification were in the range of 0.039-0.050 and 0.130-0.167 ng/mL, respectively. Good linearity (0.2-100 ng/mL) was obtained with correlation coefficients larger than 0.9967. The repeatability, expressed as relative standard deviation, ranged between 2.5% and 9.4%. The method offered the advantage of process simplicity, rapidity, automation, and sensitivity in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities of Hubei province. An acceptable recovery of monohydroxy polycyclic aromatic hydrocarbons (64-122%) represented the additional attractive features of the method in real urine analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ota, Miho; Ogawa, Shintaro; Kato, Koichi; Wakabayashi, Chisato; Kunugi, Hiroshi
2015-04-30
Previous studies demonstrated that patients with schizophrenia show greater sensitivity to psychostimulants than healthy subjects. Sensitization to psychostimulants and resultant alteration of dopaminergic neurotransmission in rodents have been suggested as a useful model of schizophrenia. This study was aimed to examine the use of methylphenidate as a psychostimulant to induce dopamine release and that of [18F]fallypride as a radioligand to estimate the release in a rat model of schizophrenia. Six rats were scanned by positron emission tomography (PET) twice before and after methylphenidate challenge to evaluate dopamine release. After the scans, these rats were sensitized by using repeated methamphetamine (MAP) administration. Then, they were re-scanned twice again before and after methylphenidate challenge to evaluate whether MAP-sensitized rats show greater sensitivity to methylphenidate. We revealed a main effect of MAP-pretreatment and that of metylphenidate challenge. We found that % change of distribution volume ratio after repeated administration of MAP was greater than that before sensitization. These results suggest that methylphenidate-induced striatal dopamine release increased after sensitization to MAP. PET scan using [18F]fallypride at methylphenidate-challenge may provide a biological marker for schizophrenia and be useful to diagnose schizophrenia. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Long-Term Effects of Neonatal Pain and Stress on Reactivity of the Nociceptive System.
Butkevich, I P; Mikhailenko, V A
2016-10-01
The influence of inflammatory pain and/or weaning stress at different terms of neonatal development on functional activity of the nociceptive system during adulthood was studied in rats. Repeated stress in 1-2-day-old rat pups (a premature baby model) enhanced pain sensitivity to peripheral inflammation in both males and females. Repeated inflammatory pain experienced by male pups aged 1-2 or 7-8 days (models of preterm and full-term baby), even in presence of mother, enhanced pain behavior under conditions of repeated inflammatory pain in adulthood. Pain sensitivity in adult animals before (hot plate test) and after formation of the inflammatory focus (formalin test) depended on the age when the animals were subjected to the injury, type of exposure, and on animal sex. The priority data obtained by us will help to understand the mechanisms of long-term effects of early injuries and are important for pediatricians and neonatologists.
Blackledge, Matthew D; Tunariu, Nina; Orton, Matthew R; Padhani, Anwar R; Collins, David J; Leach, Martin O; Koh, Dow-Mu
2016-01-01
Quantitative whole-body diffusion-weighted MRI (WB-DWI) is now possible using semi-automatic segmentation techniques. The method enables whole-body estimates of global Apparent Diffusion Coefficient (gADC) and total Diffusion Volume (tDV), both of which have demonstrated considerable utility for assessing treatment response in patients with bone metastases from primary prostate and breast cancers. Here we investigate the agreement (inter-observer repeatability) between two radiologists in their definition of Volumes Of Interest (VOIs) and subsequent assessment of tDV and gADC on an exploratory patient cohort of nine. Furthermore, each radiologist was asked to repeat his or her measurements on the same patient data sets one month later to identify the intra-observer repeatability of the technique. Using a Markov Chain Monte Carlo (MCMC) estimation method provided full posterior probabilities of repeatability measures along with maximum a-posteriori values and 95% confidence intervals. Our estimates of the inter-observer Intraclass Correlation Coefficient (ICCinter) for log-tDV and median gADC were 1.00 (0.97-1.00) and 0.99 (0.89-0.99) respectively, indicating excellent observer agreement for these metrics. Mean gADC values were found to have ICCinter = 0.97 (0.81-0.99) indicating a slight sensitivity to outliers in the derived distributions of gADC. Of the higher order gADC statistics, skewness was demonstrated to have good inter-user agreement with ICCinter = 0.99 (0.86-1.00), whereas gADC variance and kurtosis performed relatively poorly: 0.89 (0.39-0.97) and 0.96 (0.69-0.99) respectively. Estimates of intra-observer repeatability (ICCintra) demonstrated similar results: 0.99 (0.95-1.00) for log-tDV, 0.98 (0.89-0.99) and 0.97 (0.83-0.99) for median and mean gADC respectively, 0.64 (0.25-0.88) for gADC variance, 0.85 (0.57-0.95) for gADC skewness and 0.85 (0.57-0.95) for gADC kurtosis. Further investigation of two anomalous patient cases revealed that a very small proportion of voxels with outlying gADC values lead to instability in higher order gADC statistics. We therefore conclude that estimates of median/mean gADC and tumour volume demonstrate excellent inter- and intra-observer repeatability whilst higher order statistics of gADC should be used with caution when ascribing significance to clinical changes.
Jett, Julianne D; Morilak, David A
2013-03-01
Cognitive impairments associated with dysfunction of the medial prefrontal cortex (mPFC) are prominent in stress-related psychiatric disorders. We have shown that enhancing noradrenergic tone acutely in the rat mPFC facilitated extra-dimensional (ED) set-shifting on the attentional set-shifting test (AST), whereas chronic unpredictable stress (CUS) impaired ED. In this study, we tested the hypothesis that the acute facilitatory effect of norepinephrine (NE) in mPFC becomes detrimental when activated repeatedly during CUS. Using microdialysis, we showed that the release of NE evoked in mPFC by acute stress was unchanged at the end of CUS treatment. Thus, to then determine if repeated elicitation of this NE activity in mPFC during CUS may have contributed to the ED deficit, we infused a cocktail of α(1)-, β(1)-, and β(2)-adrenergic receptor antagonists into the mPFC prior to each CUS session, then tested animals drug free on the AST. Antagonist treatment prevented the CUS-induced ED deficit, suggesting that NE signaling during CUS compromised mPFC function. We confirmed that this was not attributable to sensitization of adrenergic receptor function following chronic antagonist treatment, by administering an additional microinjection into the mPFC immediately prior to ED testing. Acute antagonist treatment did not reverse the beneficial effects of chronic drug treatment during CUS, nor have any effect on baseline ED performance in chronic vehicle controls. Thus, we conclude that blockade of noradrenergic receptors in mPFC protected against the detrimental cognitive effects of CUS, and that repeated elicitation of noradrenergic facilitatory activity is one mechanism by which chronic stress may promote mPFC cognitive dysfunction.
Repeatability and oblique flow response characteristics of current meters
Fulford, Janice M.; Thibodeaux, Kirk G.; Kaehrle, William R.; ,
1993-01-01
Laboratory investigation into the precision and accuracy of various mechanical-current meters are presented. Horizontal-axis and vertical-axis meters that are used for the measurement of point velocities in streams and rivers were tested. Meters were tested for repeatability and response to oblique flows. Both horizontal- and vertical-axis meters were found to under- and over-register oblique flows with errors generally increasing as the velocity and angle of flow increased. For the oblique flow tests, magnitude of errors were smallest for horizontal-axis meters. Repeatability of all meters tested was good, with the horizontal- and vertical-axis meters performing similarly.
NASA Astrophysics Data System (ADS)
Mohamed, Omar Ahmed; Hasan Masood, Syed; Lal Bhowmik, Jahar
2018-02-01
In the additive manufacturing (AM) market, the question is raised by industry and AM users on how reproducible and repeatable the fused deposition modeling (FDM) process is in providing good dimensional accuracy. This paper aims to investigate and evaluate the repeatability and reproducibility of the FDM process through a systematic approach to answer this frequently asked question. A case study based on the statistical gage repeatability and reproducibility (gage R&R) technique is proposed to investigate the dimensional variations in the printed parts of the FDM process. After running the simulation and analysis of the data, the FDM process capability is evaluated, which would help the industry for better understanding the performance of FDM technology.
Hosoki, Koa; Aguilera-Aguirre, Leopoldo; Brasier, Allan R.; Kurosky, Alexander; Boldogh, Istvan
2016-01-01
Neutrophil recruitment is a hallmark of rapid innate immune responses. Exposure of airways of naive mice to pollens rapidly induces neutrophil recruitment. The innate mechanisms that regulate pollen-induced neutrophil recruitment and the contribution of this neutrophilic response to subsequent induction of allergic sensitization and inflammation need to be elucidated. Here we show that ragweed pollen extract (RWPE) challenge in naive mice induces C-X-C motif ligand (CXCL) chemokine synthesis, which stimulates chemokine (C-X-C motif) receptor 2 (CXCR2)-dependent recruitment of neutrophils into the airways. Deletion of Toll-like receptor 4 (TLR4) abolishes CXCL chemokine secretion and neutrophil recruitment induced by a single RWPE challenge and inhibits induction of allergic sensitization and airway inflammation after repeated exposures to RWPE. Forced induction of CXCL chemokine secretion and neutrophil recruitment in mice lacking TLR4 also reconstitutes the ability of multiple challenges of RWPE to induce allergic airway inflammation. Blocking RWPE-induced neutrophil recruitment in wild-type mice by administration of a CXCR2 inhibitor inhibits the ability of repeated exposures to RWPE to stimulate allergic sensitization and airway inflammation. Administration of neutrophils derived from naive donor mice into the airways of Tlr4 knockout recipient mice after each repeated RWPE challenge reconstitutes allergic sensitization and inflammation in these mice. Together these observations indicate that pollen-induced recruitment of neutrophils is TLR4 and CXCR2 dependent and that recruitment of neutrophils is a critical rate-limiting event that stimulates induction of allergic sensitization and airway inflammation. Inhibiting pollen-induced recruitment of neutrophils, such as by administration of CXCR2 antagonists, may be a novel strategy to prevent initiation of pollen-induced allergic airway inflammation. PMID:26086549
Hosoki, Koa; Aguilera-Aguirre, Leopoldo; Brasier, Allan R; Kurosky, Alexander; Boldogh, Istvan; Sur, Sanjiv
2016-01-01
Neutrophil recruitment is a hallmark of rapid innate immune responses. Exposure of airways of naive mice to pollens rapidly induces neutrophil recruitment. The innate mechanisms that regulate pollen-induced neutrophil recruitment and the contribution of this neutrophilic response to subsequent induction of allergic sensitization and inflammation need to be elucidated. Here we show that ragweed pollen extract (RWPE) challenge in naive mice induces C-X-C motif ligand (CXCL) chemokine synthesis, which stimulates chemokine (C-X-C motif) receptor 2 (CXCR2)-dependent recruitment of neutrophils into the airways. Deletion of Toll-like receptor 4 (TLR4) abolishes CXCL chemokine secretion and neutrophil recruitment induced by a single RWPE challenge and inhibits induction of allergic sensitization and airway inflammation after repeated exposures to RWPE. Forced induction of CXCL chemokine secretion and neutrophil recruitment in mice lacking TLR4 also reconstitutes the ability of multiple challenges of RWPE to induce allergic airway inflammation. Blocking RWPE-induced neutrophil recruitment in wild-type mice by administration of a CXCR2 inhibitor inhibits the ability of repeated exposures to RWPE to stimulate allergic sensitization and airway inflammation. Administration of neutrophils derived from naive donor mice into the airways of Tlr4 knockout recipient mice after each repeated RWPE challenge reconstitutes allergic sensitization and inflammation in these mice. Together these observations indicate that pollen-induced recruitment of neutrophils is TLR4 and CXCR2 dependent and that recruitment of neutrophils is a critical rate-limiting event that stimulates induction of allergic sensitization and airway inflammation. Inhibiting pollen-induced recruitment of neutrophils, such as by administration of CXCR2 antagonists, may be a novel strategy to prevent initiation of pollen-induced allergic airway inflammation.
Varlinskaya, Elena; Spear, Linda Patia
2009-01-01
Ontogenetic studies using a social interaction paradigm have shown that adolescent rats are less sensitive to anxiolytic properties of acute ethanol than their adult counterparts. It is not known, however, whether adaptations to these anxiolytic effects upon repeated experiences with ethanol would be similar in adolescents and adults. The present study investigated sensitivity to the anxiolytic effects of ethanol in adolescent and adult male and female Sprague-Dawley rats following 7 days of exposure [postnatal day (P) 27–33 for adolescents and P62–68 for adults] to 1 g/kg ethanol or saline (i.p.), as well as in animals left non-manipulated during this time. Anxiolytic effects of ethanol (0, 0.75, 1.0, 1.25, and 1.5 g/kg for adolescents and 0, 0.25, 0.5, 0.75, 1.0, and 1.25 g/kg for adults in Experiments 1 and 2, respectively) were examined 48 hours after the last exposure using a modified social interaction test under unfamiliar test circumstances. At both ages, repeated ethanol exposure resulted in the development of apparent sensitization to anxiolytic effects of ethanol indexed via enhancement of social investigation and transformation of social avoidance into social indifference or preference, as well as expression of tolerance to the socially inhibiting effects induced by higher ethanol doses. Evidence for the emergence of sensitization in adults and tolerance at both ages was seen not only following chronic ethanol, but also after chronic saline exposure, suggesting that chronic manipulation per se may be sufficient to alter the sensitivity of both adolescents and adults to socially-relevant effects of ethanol. PMID:20113878
Escobar, Angélica P; González, Marcela P; Meza, Rodrigo C; Noches, Verónica; Henny, Pablo; Gysling, Katia; España, Rodrigo A; Fuentealba, José A; Andrés, María E
2017-08-01
Increased locomotor activity in response to the same stimulus is an index of behavioral sensitization observed in preclinical models of drug addiction and compulsive behaviors. Repeated administration of quinpirole, a D2/D3 dopamine agonist, induces locomotor sensitization. This effect is potentiated and accelerated by co-administration of U69593, a kappa opioid receptor agonist. The mechanism underlying kappa opioid receptor potentiation of quinpirole-induced locomotor sensitization remains to be elucidated. Immunofluorescence anatomical studies were undertaken in mice brain slices and rat presynaptic synaptosomes to reveal kappa opioid receptor and D2R pre- and postsynaptic colocalization in the nucleus accumbens. Tonic and phasic dopamine release in the nucleus accumbens of rats repeatedly treated with U69593 and quinpirole was assessed by microdialysis and fast scan cyclic voltammetry. Anatomical data show that kappa opioid receptor and D2R colocalize postsynaptically in medium spiny neurons of the nucleus accumbens and the highest presynaptic colocalization occurs on the same dopamine terminals. Significantly reduced dopamine levels were observed in quinpirole, and U69593-quinpirole treated rats, explaining sensitization of D2R. Presynaptic inhibition induced by kappa opioid receptor and D2R of electrically evoked dopamine release was faster in U69593-quinpirole compared with quinpirole-repeatedly treated rats. Pre- and postsynaptic colocalization of kappa opioid receptor and D2R supports a role for kappa opioid receptor potentiating both the D2R inhibitory autoreceptor function and the inhibitory action of D2R on efferent medium spiny neurons. Kappa opioid receptor co-activation accelerates D2R sensitization by contributing to decrease dopamine release in the nucleus accumbens. © The Author 2017. Published by Oxford University Press on behalf of CINP.
Schelegle, Edward S; Miller, Lisa A; Gershwin, Laurel J; Fanucchi, Michelle V; Van Winkle, Laura S; Gerriets, Joan E; Walby, William F; Mitchell, Valerie; Tarkington, Brian K; Wong, Viviana J; Baker, Gregory L; Pantle, Lorraine M; Joad, Jesse P; Pinkerton, Kent E; Wu, Reen; Evans, Michael J; Hyde, Dallas M; Plopper, Charles G
2003-08-15
Twenty-four infant rhesus monkeys (30 days old) were exposed to 11 episodes of filtered air (FA), house dust mite allergen aerosol (HDMA), ozone (O3), or HDMA + O3 (5 days each followed by 9 days of FA). Ozone was delivered for 8 h/day at 0.5 ppm. Twelve of the monkeys were sensitized to house dust mite allergen (Dermatophagoides farinae) at ages 14 and 28 days by subcutaneous inoculation (SQ) of HDMA in alum and intraperitoneal injection of heat-killed Bordetella pertussis cells. Sensitized monkeys were exposed to HDMA aerosol for 2 h/day on days 3-5 of either FA (n = 6) or O3 (n = 6) exposure. Nonsensitized monkeys were exposed to either FA (n = 6) or O3 (n = 6). During the exposure regimen, parameters of allergy (i.e., serum IgE, histamine, and eosinophilia), airways resistance, reactivity, and structural remodeling were evaluated. Eleven repeated 5-day cycles of inhaling 0.5 ppm ozone over a 6-month period had only mild effects on the airways of nonsensitized infant rhesus monkeys. Similarly, the repeated inhalation of HDMA by HDMA-sensitized infant monkeys resulted in only mild airway effects, with the exception of a marked increase in proximal airway and terminal bronchiole content of eosinophils. In contrast, the combined cyclic inhalation of ozone and HDMA by HDMA sensitized infants monkeys resulted in a marked increase in serum IgE, serum histamine, and airways eosinophilia. Furthermore, combined cyclic inhalation of ozone and HDMA resulted in even greater alterations in airway structure and content that were associated with a significant elevation in baseline airways resistance and reactivity. These results suggest that ozone can amplify the allergic and structural remodeling effects of HDMA sensitization and inhalation.
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, Dan; Zhang, Jun; Zhao, Dian
2016-09-15
A near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method using Ln{sup 3+} (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H{sub 3}BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd{sub 0.676}Yb{sub 0.324}BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K), and the maximum relative sensitivity is determined to be 1.187% K{sup −1} at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing. - Graphical abstract: A near infrared luminescent MOFs thermometer (Nd{sub 0.054}Yb{sub 0.946}BTCmore » ) displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K). Display Omitted - Highlights: • A ratiometric near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method. • The maximum relative sensitivity of Nd{sub 0.676}Yb{sub 0.324}BTC is determined to be 1.187% K{sup −1} at 323 K. • Nd{sub 0.676}Yb{sub 0.324}BTC showed excellent repeatability in the physiological temperature range (288–323 K).« less
Repeated high-intensity exercise modulates Ca(2+) sensitivity of human skeletal muscle fibers.
Gejl, K D; Hvid, L G; Willis, S J; Andersson, E; Holmberg, H-C; Jensen, R; Frandsen, U; Hansen, J; Plomgaard, P; Ørtenblad, N
2016-05-01
The effects of short-term high-intensity exercise on single fiber contractile function in humans are unknown. Therefore, the purposes of this study were: (a) to access the acute effects of repeated high-intensity exercise on human single muscle fiber contractile function; and (b) to examine whether contractile function was affected by alterations in the redox balance. Eleven elite cross-country skiers performed four maximal bouts of 1300 m treadmill skiing with 45 min recovery. Contractile function of chemically skinned single fibers from triceps brachii was examined before the first and following the fourth sprint with respect to Ca(2+) sensitivity and maximal Ca(2+) -activated force. To investigate the oxidative effects of exercise on single fiber contractile function, a subset of fibers was incubated with dithiothreitol (DTT) before analysis. Ca(2+) sensitivity was enhanced by exercise in both MHC I (17%, P < 0.05) and MHC II (15%, P < 0.05) fibers. This potentiation was not present after incubation of fibers with DTT. Specific force of both MHC I and MHC II fibers was unaffected by exercise. In conclusion, repeated high-intensity exercise increased Ca(2+) sensitivity in both MHC I and MHC II fibers. This effect was not observed in a reducing environment indicative of an exercise-induced oxidation of the human contractile apparatus. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Amino terminus of substance P potentiates kainic acid-induced activity in the mouse spinal cord.
Larson, A A; Sun, X
1992-12-01
Sensitization to the behavioral effects produced by repeated injections of kainic acid (KA) into the mouse spinal cord area has been previously shown to be abolished by pretreatment with capsaicin, a neurotoxin of substance P (SP)-containing primary afferent C-fibers. While SP has a variety of well characterized biological actions that are mediated by interactions of its COOH terminus with neurokinin receptors, more recently we have characterized an amino-terminally directed SP binding site. The present studies were initiated to determine whether behavioral sensitization to repeated injections of intrathecally administered KA is mediated by the COOH or NH2 terminal of SP. In the present studies, pretreatment with SP(1-7), an NH2-terminal fragment of SP, but not SP(5-11), a COOH-terminal fragment, potentiated KA-induced behavioral activity in mice. Pretreatment with [D-Pro2,D-Phe7]SP(1-7), an inhibitor of SP NH2-terminal binding, blocked the potentiative effect of SP(1-7) as well as the sensitization to repeated injections of KA. In contrast, [D-Pro2,D-Trp7,9]SP, a neurokinin antagonist, had little effect on behavioral sensitization to KA. The present study suggests that SP has an important modulatory role on excitatory amino acid activity in the spinal cord that is mediated by an action of the NH2 terminal of SP at a non-neurokinin receptor.
The human repeated insult patch test in the 21st century: a commentary.
Basketter, David A
2009-01-01
The human repeated insult patch test (HRIPT) is over half a century old, but is still used in several countries as a confirmatory test in the safety evaluation of skin sensitizers. This is despite the criticism it receives from an ethical perspective and regarding the scientific validity of such testing. In this commentary, the HRIPT is reviewed, with emphasis on ethical aspects and where the test can, and cannot, contribute in a scientifically meaningful manner to safety evaluation. It is concluded that where there is a specific rationale for testing, for example, to substantiate a no-effect level for a sensitizing chemical or to ensure that matrix effects are not making an unexpected contribution to sensitizing potency, then rigorous independent review may confirm that an HRIPT is ethical and scientifically justifiable. The possibility that sensitization may be induced in volunteers dictates that HRIPTs should be conducted rarely and in cases where the benefits overwhelmingly outweigh the risk. However, for the very large majority of HRIPTs conducted concerning the risk of skin sensitization, there is neither scientific justification nor any other merit.
Richman, Jesse; Zangalli, Camila; Lu, Lan; Wizov, Sheryl S; Spaeth, Eric; Spaeth, George L
2015-01-01
(1) To determine the ability of a novel, internet-based contrast sensitivity test titled the Spaeth/Richman Contrast Sensitivity Test (SPARCS) to identify patients with glaucoma. (2) To determine the test-retest reliability of SPARCS. A prospective, cross-sectional study of patients with glaucoma and controls was performed. Subjects were assessed by SPARCS and the Pelli-Robson chart. Reliability of each test was assessed by the intraclass correlation coefficient and the coefficient of repeatability. Sensitivity and specificity for identifying glaucoma was also evaluated. The intraclass correlation coefficient for SPARCS was 0.97 and 0.98 for Pelli-Robson. The coefficient of repeatability for SPARCS was ±6.7% and ±6.4% for Pelli-Robson. SPARCS identified patients with glaucoma with 79% sensitivity and 93% specificity. SPARCS has high test-retest reliability. It is easily accessible via the internet and identifies patients with glaucoma well. NCT01300949. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Fuel ethanol production from sweet sorghum using repeated-batch fermentation.
Chohnan, Shigeru; Nakane, Megumi; Rahman, M Habibur; Nitta, Youji; Yoshiura, Takanori; Ohta, Hiroyuki; Kurusu, Yasurou
2011-04-01
Ethanol was efficiently produced from three varieties of sweet sorghum using repeated-batch fermentation without pasteurization or acidification. Saccharomyces cerevisiae cells could be recycled in 16 cycles of the fermentation process with good ethanol yields. This technique would make it possible to use a broader range of sweet sorghum varieties for ethanol production. Copyright © 2010 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
A parent‐completed respiratory questionnaire for 1‐year‐old children: repeatability
Strippoli, Marie‐Pierre F; Silverman, Michael; Michel, Gisela; Kuehni, Claudia E
2007-01-01
Background and aims There are few standardised questionnaires for the assessment of respiratory symptoms in preschool children. We have developed and tested the short‐term repeatability of a postal questionnaire on respiratory symptoms for 1‐year‐old children. Methods A newly developed postal questionnaire for the assessment of wheeze and other respiratory symptoms was sent to parents of a population‐based random sample of 4300 children aged 12–24 months. After an interval of 3 months, a random sample of 800 respondents received the questionnaire a second time. The responses were compared using Cohen's kappa (κ) to assess agreement corrected for chance. Results The first questionnaire was returned by 3194 (74%) families, the second one by 460/800 (58%). Repeatability was excellent (κ 0.80–0.96) for questions on household characteristics, environmental exposures and family history, good (κ 0.61–0.80) for questions on prevalence, severity and treatment of wheeze, and moderate (κ 0.39–0.66) for chronic cough and upper respiratory symptoms. Conclusions This short postal questionnaire designed for use in population‐based studies has excellent repeatability for family and household characteristics and good repeatability for questions on wheeze. Short‐term changes in symptom status might be responsible for variable answers on recent chronic cough and upper respiratory symptoms. Overall, the questionnaire is a valuable instrument for community‐based research on respiratory symptoms in 1 to 2‐year‐old children. PMID:17502330
Design and Implementation of a Micromechanical Silicon Resonant Accelerometer
Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing
2013-01-01
The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C. PMID:24256978
NASA Technical Reports Server (NTRS)
Wilkes, R. L.; Kennedy, R. S.; Dunlap, W. P.; Lane, N. E.
1986-01-01
A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.
Zhang, Zhengxiang; Yan, Bo; Liu, Kelin; Liao, Yiping; Liu, Huwei
2009-01-01
The first application of charged polymer-protected gold nanoparticles (Au NPs) as semi-permanent capillary coating in CE-MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run-to-run and capillary-to-capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin-related alkaloids was achieved on the PDDA-protected Au NPs-coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20 degrees C, applied voltage -20 kV, and capillary effective length 60.0 cm. CE-MS analysis with run-to-run RSDs (n=5) of migration time in the range of 0.43-0.62% and RSDs (n=5) of peak area in the range of 1.49-4.68% was obtained. The established CE-MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC-MS and GC-MS for illicit drug control.
Serial-order learning impairment and hypersensitivity-to-interference in dyscalculia.
De Visscher, Alice; Szmalec, Arnaud; Van Der Linden, Lize; Noël, Marie-Pascale
2015-11-01
In the context of heterogeneity, the different profiles of dyscalculia are still hypothetical. This study aims to link features of mathematical difficulties to certain potential etiologies. First, we wanted to test the hypothesis of a serial-order learning deficit in adults with dyscalculia. For this purpose we used a Hebb repetition learning task. Second, we wanted to explore a recent hypothesis according to which hypersensitivity-to-interference hampers the storage of arithmetic facts and leads to a particular profile of dyscalculia. We therefore used interfering and non-interfering repeated sequences in the Hebb paradigm. A final test was used to assess the memory trace of the non-interfering sequence and the capacity to manipulate it. In line with our predictions, we observed that people with dyscalculia who show good conceptual knowledge in mathematics but impaired arithmetic fluency suffer from increased sensitivity-to-interference compared to controls. Secondly, people with dyscalculia who show a deficit in a global mathematical test suffer from a serial-order learning deficit characterized by a slow learning and a quick degradation of the memory trace of the repeated sequence. A serial-order learning impairment could be one of the explanations for a basic numerical deficit, since it is necessary for the number-word sequence acquisition. Among the different profiles of dyscalculia, this study provides new evidence and refinement for two particular profiles. Copyright © 2015 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Objective: The primary aim of this randomized controlled trial is to determine whether the relative reinforcing value (RRV) of vegetables compared to a snack food can be increased through repeated exposure (incentive sensitization) to amounts of vegetables recommended by the Dietary Guidelines for A...
Scibelli, Angela C.; McKinnon, Carrie S.; Reed, Cheryl; Burkhart-Kasch, Sue; Li, Na; Baba, Harue; Wheeler, Jeanna M.
2012-01-01
Rationale Genetically determined differences in susceptibility to drug-induced sensitization could be related to risk for drug consumption. Objectives Studies were performed to determine whether selective breeding could be used to create lines of mice with different magnitudes of locomotor sensitization to methamphetamine (MA). MA sensitization (MASENS) lines were also examined for genetically correlated responses to MA. Methods Beginning with the F2 cross of C57BL/6J and DBA/2J strains, mice were tested for locomotor sensitization to repeated injections of 1 mg/kg MA and bred based on magnitude of sensitization. Five selected offspring generations were tested. All generations were also tested for MA consumption, and some were tested for dose-dependent locomotor-stimulant responses to MA, consumption of saccharin, quinine, and potassium chloride as a measure of taste sensitivity, and MA clearance after acute and repeated MA. Results Selective breeding resulted in creation of two lines [MA high sensitization (MAHSENS) and MA low sensitization (MALSENS)] that differed in magnitude of MA-induced sensitization. Initially, greater MA consumption in MAHSENS mice reversed over the course of selection so that MALSENS mice consumed more MA. MAHSENS mice exhibited greater sensitivity to the acute stimulant effects of MA, but there were no significant differences between the lines in MA clearance from blood. Conclusions Genetic factors influence magnitude of MA-induced locomotor sensitization and some of the genes involved in magnitude of this response also influence MA sensitivity and consumption. Genetic factors leading to greater MA-induced sensitization may serve a protective role against high levels of MA consumption. PMID:21088960
Lopez, M F; Becker, H C; Chandler, L J
2014-11-01
Studies in animal models have shown that repeated episodes of alcohol dependence and withdrawal promote escalation of drinking that is presumably associated with alterations in the addiction neurocircuitry. Using a lithium chloride-ethanol pairing procedure to devalue the reinforcing properties of ethanol, the present study determined whether multiple cycles of chronic intermittent ethanol (CIE) exposure by vapor inhalation also alters the sensitivity of drinking behavior to the devaluation of ethanol's reinforcing effects. The effect of devaluation on operant ethanol self-administration and extinction was examined in mice prior to initiation of CIE (short drinking history) and after repeated cycles of CIE or air control exposure (long drinking history). Devaluation significantly attenuated the recovery of baseline ethanol self-administration when tested either prior to CIE or in the air-exposed controls that had experienced repeated bouts of drinking but no CIE. In contrast, in mice that had undergone repeated cycles of CIE exposure that promoted escalation of ethanol drinking, self-administration was completely resistant to the effect of devaluation. Devaluation had no effect on the time course of extinction training in either pre-CIE or post-CIE mice. Taken together, these results are consistent with the suggestion that repeated cycles of ethanol dependence and withdrawal produce escalation of ethanol self-administration that is associated with a change in sensitivity to devaluation of the reinforcing properties of ethanol. Copyright © 2014 Elsevier Inc. All rights reserved.
2012-01-01
Background Repeated morphine exposure can induce behavioral sensitization. There are evidences have shown that central gamma-aminobutyric acid (GABA) system is involved in morphine dependence. However, the effect of a GABAB receptor agonist baclofen on morphine-induced behavioral sensitization in rats is unclear. Methods We used morphine-induced behavioral sensitization model in rat to investigate the effects of baclofen on behavioral sensitization. Moreover, dopamine release in the shell of the nucleus accumbens was evaluated using microdialysis assay in vivo. Results The present study demonstrated that morphine challenge (3 mg/kg, s.c.) obviously enhanced the locomotor activity following 4-day consecutive morphine administration and 3-day withdrawal period, which indicated the expression of morphine sensitization. In addition, chronic treatment with baclofen (2.5, 5 mg/kg) significantly inhibited the development of morphine sensitization. It was also found that morphine challenge 3 days after repeated morphine administration produced a significant increase of extracellular dopamine release in nucleus accumbens. Furthermore, chronic treatment with baclofen decreased the dopamine release induced by morphine challenge. Conclusions Our results indicated that gamma-aminobutyric acid system plays an important role in the morphine sensitization in rat and suggested that behavioral sensitization is a promising model to study the mechanism underlying drug abuse. PMID:22559224
Boonchai, Waranya; Sathaworawong, Angkana; Wongpraparut, Chanisada; Wanitphakdeedecha, Rungsima
2015-10-01
Ablative fractional skin resurfacing has become popular and proven to be useful in treating scars, photoaging and wrinkles. Although post-inflammatory hyperpigmentation (PIH) is the most common complication especially in dark-skinned patients like Asian. Several modalities have been used to overcome the PIH. To determine the sensitization potential of sunscreen applied immediately after ablative fractional skin resurfacing. Sixty volunteers were recruited. Of these 30 subjects were from previous ablative fractional skin resurfacing study who applied broad-spectrum sunscreen containing anti-inflammatory agent starting on the first day after resurfacing and another 30 non-resurfacing subjects had applied the same sunscreen on the intact skin. All subjects were patch/photopatch tested for sensitization study by using modified human repeated insult patch test (HRIPT). There were significantly higher sensitization rate of UV-filter, octocrylene and the sunscreen in resurfacing group than in non-resurfacing group. Early application of sunscreen after ablative fractional skin resurfacing has increased the incidence of sensitization potential of sunscreen. The sunscreen is recommended to start using from D3 after fractional ablative skin resurfacing to ensure the complete recovery of skin barrier and minimize the risk of sensitization.
Wang, Xinran; Yang, Shupeng; Li, Yi; Zhang, Jinzhen; Jin, Yue; Zhao, Wen; Zhang, Yongxin; Huang, Jingping; Wang, Peng; Wu, Cuiling; Zhou, Jinhui
2018-03-23
A robust and sensitive method of solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established and performed for the simultaneous determination of eleven aminoglycosides (AGs) in royal jelly and honey. After sample extraction by a phosphate buffer containing trichloroacetic acid (TCA) and ethylenediaminetetracetic acid disodium salt (Na 2 EDTA), the extraction solution was subjected to a parallel solid-phase extraction for clean-up prior to the LC-MS/MS analysis. The same method was applied to analyze two completely different matrices, honey and royal jelly. Good sensitivity, repeatability, and recovery were obtained by using the mobile phase without an ion-pairing reagent such as heptafluorobutyric acid (HFBA) or sodium heptanesulfonate. The calibration curves of the honey and royal jelly samples exhibited a good linear response (R 2 > 0.99) at six concentrations in the range of 10-1000 μg/mL. The limit of quantification (LOQ) of the AGs ranged from 10 to 25 μg/kg in the honey and from 12.5 to 25 μg/kg in the royal jelly. The recoveries of the AGs for the honey and royal jelly samples were in the range of 79.48% to 108.95% and 74.61% to 113.70% respectively and the relative standard deviations (RSDs) were between 1.23% and 9.59%, and between 1.51% and 9.98%, respectively. The proposed approach has been allowed in China as a reference method for the simultaneous determination of eleven AGs in honey and royal jelly. Copyright © 2018 Elsevier B.V. All rights reserved.
Frelin-Labalme, Anne-Marie; Ledoux, Xavier
2017-01-01
Objective: Small animal image-guided irradiators have recently been developed to mimic the delivery techniques of clinical radiotherapy. A dosemeter adapted to millimetric beams of medium-energy X-rays is then required. This work presents the characterization of a dosemeter prototype for this particular application. Methods: A scintillating optical fibre dosemeter (called DosiRat) has been implemented to perform real-time dose measurements with the dedicated small animal X-RAD® 225Cx (Precision X-Ray, Inc., North Branford, CT) irradiator. Its sensitivity, stem effect, stability, linearity and measurement precision were determined in large field conditions for three different beam qualities, consistent with small animal irradiation and imaging parameters. Results: DosiRat demonstrates good sensitivity and stability; excellent air kerma and air kerma rate linearity; and a good repeatability for air kerma rates >1 mGy s−1. The stem effect was found to be negligible. DosiRat showed limited precision for low air kerma rate measurements (<1 mGy s−1), typically for imaging protocols. A positive energy dependence was found that can be accounted for by calibrating the dosemeter at the needed beam qualities. Conclusion: The dosimetric performances of DosiRat are very promising. Extensive studies of DosiRat energy dependence are still required. Further developments will allow to reduce the dosemeter size to ensure millimetric beams dosimetry and perform small animal in vivo dosimetry. Advances in knowledge: Among existing point dosemeters, very few are dedicated to both medium-energy X-rays and millimetric beams. Our work demonstrated that scintillating fibre dosemeters are suitable and promising tools for real-time dose measurements in the small animal field of interest. PMID:27556813
Biomimetic piezoelectric quartz crystal sensor with chloramphenicol-imprinted polymer sensing layer.
Ebarvia, Benilda S; Ubando, Isaiah E; Sevilla, Fortunato B
2015-11-01
The measurement of banned antibiotic like chloramphenicol is significant for customer protection and safety. The presence of residual antibiotics in foods and food products of animal origin could pose as health hazards and affect food quality for global acceptance. In this study, the potential of a chloramphenicol sensor based on molecularly imprinted polymer (MIP) coupled with a piezoelectric quartz crystal was explored. The MIP was prepared by precipitation polymerization at 60 °C. Methacrylic acid was used as monomer, trimethylolpropane trimethacrylate (TRIM) as crosslinker, and chloramphenicol as the template. Template removal on the resulting polymer was done by extraction using methanol-acetic acid. Characterization of the MIP and NIP were conducted by spectroscopic and microscopic methods. These further supported the imprinting and rebinding process of chloramphenicol to the polymer matrix. The chloramphenicol sensor was devised by spin-coating onto one side of the 10 MHz AT-cut quartz crystal the MIP suspension in polyvinylchloride-tetrahydrofuran (6:2:1 w/w/v) solution. Optimization of sensor response was performed by varying the type of cross-linker, amount of MIP sensing layer, curing time, and pH. The sensor exhibited good sensitivity of about 73 Hz/log (conc., µg mL(-1)) and good repeatability (rsd<10%). A linear relationship (r(2)=0.9901) between frequency shift and chloramphenicol concentration in the range of 1×10(-6) up to 1×10(-1) µg/mL was obtained. The sensor response was highly selective to chloramphenicol than with other compounds of similar chemical structures. Acceptable percent recovery was obtained for real sample analysis using the sensor. The proposed sensor could be a promising low cost and highly sensitive approach for residual chloramphenicol quantification in food products. Copyright © 2015 Elsevier B.V. All rights reserved.
Mamo, Samuel Kassahun; Gonzalez-Rodriguez, Jose
2014-01-01
The explosive triacetone triperoxide (TATP), which can be prepared from commercially readily available reagents following an easy synthetic procedure, is one of the most common components of improvised explosive devices (IEDs). Molecularly-imprinted polymer (MIP) electrochemical sensors have proved useful for the determination of different compounds in different matrices with the required sensitivity and selectivity. In this work, a highly sensitive and selective molecularly imprinted polymer with electrochemical capabilities for the determination of TATP has been developed. The molecular imprinting has been performed via electropolymerisation onto a glassy carbon electrode surface by cyclic voltammetry from a solution of pyrrole functional monomer, TATP template and LiClO4. Differential Pulse Voltammetry of TATP, with LiClO4 as supporting electrolyte, was performed in a potential range of −2.0 V to +1.0 V (vs. Ag/AgCl). Three-factor two-level factorial design was used to optimise the monomer concentration at 0.1 mol·L−1, template concentration at 100 mmol·L−1 and the number of cyclic voltammetry scan cycles to 10. The molecularly imprinted polymer-modified glassy carbon electrode demonstrated good performance at low concentrations for a linear range of 82–44,300 μg·L−1 and a correlation coefficient of r2 = 0.996. The limits of detection (LoD) and quantification (LoQ) achieved were 26.9 μg·L−1 and 81.6 μg·L−1, respectively. The sensor demonstrated very good repeatability with precision values (n = 6, expressed as %RSD) of 1.098% and 0.55% for 1108 and 2216 μg·L−1, respectively. It also proved selective for TATP in the presence of other explosive substances such as PETN, RDX, HMX, and TNT. PMID:25490589
Park, Seongmin A; Jeong, Soyeong; Jeong, Jaeseung
2013-01-01
We explore the neural underpinnings of gender differences in cooperation and their modulation by intensive media watching. We compared cooperative decisions and electroencephalograph data between genders from who participated in repeated rounds of the public goods game (PGG) and investigated within groups changes that occurred after watching a TV program known as "investigative reporting" that denounces unfair advantages taken by free-riders against the public. Women tended to be more cooperative than men during early rounds of PGG, mostly because they react differently to the defection of others; women also had greater β and γ band activity in regions estimated to be associated with social cognition. These gender differences disappeared after participants watched the TV programs: women were more likely to choose free-riding in response to the defection of others that elicits significant increases in γ band activities that were estimated to be right insula. Greater activity in social cognition leads women to make decisions considering the motives of others, while men tend to make a decision by complying with the social norm. Watching the investigative TV reports produced a greater negative emotion to the defection and led women, in a similar manner as men, to opt for a "tit-for-tat" strategy.
Wu, Baoyan; Hou, Shihua; Miao, Zhiying; Zhang, Cong; Ji, Yanhong
2015-01-01
A novel amperometric glucose biosensor was fabricated by layer-by-layer self-assembly of gold nanorods (AuNRs) and glucose oxidase (GOD) onto single-walled carbon nanotubes (SWCNTs)-functionalized three-dimensional sol-gel matrix. A thiolated aqueous silica sol containing SWCNTs was first assembled on the surface of a cleaned Au electrode, and then the alternate self-assembly of AuNRs and GOD were repeated to assemble multilayer films of AuNRs-GOD onto SWCNTs-functionalized silica gel for optimizing the biosensor. Among the resulting glucose biosensors, the four layers of AuNRs-GOD-modified electrode showed the best performance. The sol-SWCNTs-(AuNRs-GOD)4/Au biosensor exhibited a good linear range of 0.01–8 mM glucose, high sensitivity of 1.08 μA/mM, and fast amperometric response within 4 s. The good performance of the proposed glucose biosensor could be mainly attributed to the advantages of the three-dimensional sol-gel matrix and stereo self-assembly films, and the natural features of one-dimensional nanostructure SWCNTs and AuNRs. This study may provide a new facile way to fabricate the enzyme-based biosensor with high performance. PMID:28347080
Benedict, Ralph H B; Smerbeck, Audrey; Parikh, Rajavi; Rodgers, Jonathan; Cadavid, Diego; Erlanger, David
2012-09-01
Cognitive impairment is common in multiple sclerosis (MS), but is seldom assessed in clinical trials investigating the effects of disease-modifying therapies. The Symbol Digit Modalities Test (SDMT) is a particularly promising tool due to its sensitivity and robust correlation with brain magnetic resonance imaging (MRI) and vocational disability. Unfortunately, there are no validated alternate SDMT forms, which are needed to mitigate practice effects. The aim of the study was to assess the reliability and equivalence of SDMT alternate forms. Twenty-five healthy participants completed each of five alternate versions of the SDMT - the standard form, two versions from the Rao Brief Repeatable Battery, and two forms specifically designed for this study. Order effects were controlled using a Latin-square research design. All five versions of the SDMT produced mean values within 3 raw score points of one another. Three forms were very consistent, and not different by conservative statistical tests. The SDMT test-retest reliability using these forms was good to excellent, with all r values exceeding 0.80. For the first time, we find good evidence that at least three alternate versions of the SDMT are of equivalent difficulty in healthy adults. The forms are reliable, and can be implemented in clinical trials emphasizing cognitive outcomes.
Sun, Shi-Hao; Xie, Jian-Ping; Xie, Fu-Wei; Zong, Yong-Li
2008-02-01
A method coupling needle-based derivatization headspace liquid-phase microextraction with gas chromatography-mass spectrometry (HS-LPME/GC-MS) was developed to determine volatile organic acids in tobacco. The mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and decane was utilized as the solvent for HS-LPME, resulting that extraction and derivatization were simultaneously completed in one step. The solvent served two purposes. First, it pre-concentrated volatile organic acids in the headspace of tobacco sample. Second, the volatile organic acids extracted were derivatized to form silyl derivatives in the drop. The main parameters affecting needle-based derivatization HS-LPME procedure such as extraction and derivatization reagent, microdrop volume, extraction and derivatization time, and preheating temperature and preheating time were optimized. The standard addition approach was essential to obtain accurate measurements by minimizing matrix effects. Good linearity (R(2)> or =0.9804) and good repeatability (RSDs< or =15.3%, n=5) for 16 analytes in spiked standard analytes sample were achieved. The method has the additional advantages that at the same time it is simple, fast, effective, sensitive, selective, and provides an overall profile of volatile organic acids in the oriental tobacco. This paper does offer an alternative approach to determine volatile organic acids in tobacco.
Non-enzymatic glucose sensor based on electrodeposited copper on carbon paste electrode (Cu/CPE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nurani, Dita Arifa, E-mail: d.arifa@sci.ui.ac.id; Wibowo, Rahmat; Fajri, Iqbal Farhan El
The development of non-enzymatic glucose sensor has much attention due to their applications in glucose monitoring. In this research, copper oxide is used as a non-enzymatic glucose sensor by oxidizing glucose to gluconolactone. Copper was electrodeposited on Carbon paste electrode (CPE) at constant potential. The experimental condition was varied in electrodeposition of Cu with the following parameters: Electrodeposition time 60 s, 120 s and 180 s and potential reduction -0.166 V, -0.266 V and -0.366 V. The effective performance of these working electrodes in sensing glucose was investigated. The Cu/CPE which used -0.366 V potential reduction and 120 s electrodeposition time shows the bestmore » performance. The amperometric response current in concentration range 1.6-62.5 mM of glucose gives the good linearity R{sup 2} = 0.9988, low detection limit 0.6728 mM and high sensitivity 1183.59 µA mM{sup −1}cm{sup −2}. Furthermore this sensor exhibited a good repeatability with %RSD = 1.31% (n=10) and high stability with %RSD = 1.51% (n=5 days). The homogeneity of Cu particles on CPE was investigated by Scanning Electron Microscope (SEM).« less
Gündoğdu, Aslı; Aydın, Elif Burcu; Sezgintürk, Mustafa Kemal
2017-11-15
A new, low-cost electrochemical immunosensor was developed for rapid detection of Melanoma-associated antigen 1 (MAGE-1), a cancer biomarker. The fabrication procedure of immunosensor was based on the covalent immobilization of anti-MAGE-1, biorecognition molecule, on ITO electrode by carboxyethylsilanetriol (CTES) monolayer. The biosensing MAGE-1 antigen was monitored by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) technique. Apart from these techniques, single frequency impedance (SFI) was used for investigation of antibody-antigen interactions. Scanning electron microscopy (SEM), fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) were utilized for characterization of the proposed biosensor. To fabricate highly sensitive, good stability immunosensor, some parameters were optimized. Under optimal conditions, the developed electrochemical immunosensor for MAGE-1 exhibited a dynamic range of 4 fg/mL and 200 fg/mL with a low detection limit of 1.30 fg/mL. It had acceptable repeatability (5.05%, n = 20) and good storage stability (3.58% loss after 10 weeks). Moreover, this electrochemical immunosensor has been successfully applied to the determination of MAGE-1 in human serum samples. Copyright © 2017 Elsevier Inc. All rights reserved.
Gao, Jun; Qin, Rongyin; Li, Ming
2015-04-01
The present study investigated how repeated administration of aripiprazole (a novel antipsychotic drug) alters its behavioral effects in two behavioral tests of antipsychotic activity and whether this alteration is correlated with an increase in dopamine D2 receptor function. Male adult Sprague-Dawley rats were first repeatedly tested with aripiprazole (3, 10 and 30 mg/kg, subcutaneously (sc)) or vehicle in a conditioned avoidance response (CAR) test or a phencyclidine (PCP) (3.20 mg/kg, sc)-induced hyperlocomotion test daily for five consecutive days. After 2-3 days of drug-free retraining or resting, all rats were then challenged with aripiprazole (1.5 or 3.0 mg/kg, sc). Repeated administration of aripiprazole progressively increased its inhibition of avoidance responding and PCP-induced hyperlocomotion. More importantly, rats previously treated with aripiprazole showed significantly lower avoidance response and lower PCP-induced hyperlocomotion than those previously treated with vehicle in the challenge tests. An increased sensitivity to quinpirole (a selective D2/3 agonist) in prior aripiprazole-treated rats was also found in the quinpirole-induced hyperlocomotion test, suggesting an enhanced D2/3-mediated function. These findings suggest that aripiprazole, despite its distinct receptor mechanisms of action, induces a sensitization effect similar to those induced by other antipsychotic drugs and this effect may be partially mediated by brain plasticity involving D2/3 receptor systems. © The Author(s) 2014.
Gao, Jun; Qin, Rongyin; Li, Ming
2016-01-01
The present study investigated how repeated administration of aripiprazole (a novel antipsychotic drug) alters its behavioral effects in two behavioral tests of antipsychotic activity and whether this alteration is correlated with an increase in dopamine D2 receptor function. Male adult Sprague-Dawley rats were first repeatedly tested with aripiprazole (3, 10 and 30 mg/kg, subcutaneously (sc)) or vehicle in a conditioned avoidance response (CAR) test or a phencyclidine (PCP) (3.20 mg/kg, sc)-induced hyperlocomotion test daily for five consecutive days. After 2–3 days of drug-free retraining or resting, all rats were then challenged with aripiprazole (1.5 or 3.0 mg/kg, sc). Repeated administration of aripiprazole progressively increased its inhibition of avoidance responding and PCP-induced hyperlocomotion. More importantly, rats previously treated with aripiprazole showed significantly lower avoidance response and lower PCP-induced hyperlocomotion than those previously treated with vehicle in the challenge tests. An increased sensitivity to quinpirole (a selective D2/3 agonist) in prior aripiprazole-treated rats was also found in the quinpirole-induced hyperlocomotion test, suggesting an enhanced D2/3-mediated function. These findings suggest that aripiprazole, despite its distinct receptor mechanisms of action, induces a sensitization effect similar to those induced by other antipsychotic drugs and this effect may be partially mediated by brain plasticity involving D2/3 receptor systems. PMID:25586399
Taraschenko, Olga D.; Rubbinaccio, Heather Y.; Shulan, Joseph M.; Glick, Stanley D.; Maisonneuve, Isabelle M.
2007-01-01
Owing to multiple anatomical connections and functional interactions between the habenulo-interpeduncular and the mesolimbic pathways, it has been proposed that these systems could together mediate the reinforcing properties of addictive drugs. 18-Methoxycoronaridine, an agent that reduces morphine self-administration and attenuates dopamine sensitization in the nucleus accumbens in response to repeated morphine, has been shown to produce these effects by acting in the medial habenula and interpeduncular nucleus. Acetylcholine, one of the predominant neurotransmitters in the interpeduncular nucleus, may be a major determinant of these interactions. To determine if and how morphine acts in the interpeduncular nucleus, the effects of acute and repeated administration of morphine on extracellular acetylcholine levels in this brain area were assessed. In addition, the motor behavior of rats receiving repeated morphine administration was monitored during microdialysis sessions. Acutely, morphine produced a biphasic effect on extracellular acetylcholine levels in the interpeduncular nucleus such that low and high doses of morphine (i.e., 5 and 20 mg/kg i.p.) significantly increased and decreased acetylcholine levels, respectively. Repeated administration of the same doses of morphine resulted in tolerance to the inhibitory but not to the stimulatory effects; tolerance was accompanied by sensitization to morphine-induced changes in locomotor activity and stereotypic behavior. The latter results suggest that tolerance to morphine's effect on the cholinergic habenulo-interpeduncular pathway is related to its sensitizing effects on the mesostriatal dopaminergic pathways. PMID:17544456
Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret
2017-05-24
Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wagner, Angela; Simmons, Alan N; Oberndorfer, Tyson A; Frank, Guido K W; McCurdy-McKinnon, Danyale; Fudge, Julie L; Yang, Tony T; Paulus, Martin P; Kaye, Walter H
2015-12-30
Recent studies show that higher-order appetitive neural circuitry may contribute to restricted eating in anorexia nervosa (AN) and overeating in bulimia nervosa (BN). The purpose of this study was to determine whether sensitization effects might underlie pathologic eating behavior when a taste stimulus is administered repeatedly. Recovered AN (RAN, n=14) and BN (RBN, n=15) subjects were studied in order to avoid the confounding effects of altered nutritional state. Functional magnetic resonance imaging (fMRI) measured higher-order brain response to repeated tastes of sucrose (caloric) and sucralose (non-caloric). To test sensitization, the neuronal response to the first and second administration was compared. RAN patients demonstrated a decreased sensitization to sucrose in contrast to RBN patients who displayed the opposite pattern, increased sensitization to sucrose. However, the latter was not as pronounced as in healthy control women (n=13). While both eating disorder subgroups showed increased sensitization to sucralose, the healthy controls revealed decreased sensitization. These findings could reflect on a neuronal level the high caloric intake of RBN during binges and the low energy intake for RAN. RAN seem to distinguish between high energy and low energy sweet stimuli while RBN do not. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Gibbons-Burgener, S N; Kaneene, J B; Lloyd, J W; Leykam, J F; Erskine, R J
2001-11-01
To determine the likelihood of false-positive results when testing milk samples from individual cows by use of 3 commercially available assays (Penzyme MilkTest and the SNAP beta-lactam and Delvo-SP assays) labeled for use with commingled milk. Milk samples from 111 cows with mild clinical mastitis. Cows were randomly assigned to the control (no antimicrobials) or intramammary treatment group. Posttreatment milk samples were collected at the first milking after the labeled withholding period or an equivalent time for controls, randomly ordered, and tested twice by use of each assay and once by use of high-performance liquid chromatography. Sensitivity, specificity, and positive and negative predictive values were determined for each assay. Concordance of results for the same sample was assessed for each assay by calculating kappa. Sensitivities of the Delvo-SP and SNAP lactam assays were > 90%, whereas the sensitivity of the Penzyme Milk Test was 60%. Positive predictive values (range, 39.29 to 73.68%) were poor for all 3 assays. Concordance of test results was excellent for the SNAP beta-lactam and Delvo-SP assays (kappa = 0.846 and 0.813, respectively) but was less for the Penzyme MilkTest (kappa = 0.545). Because of the low positive predictive values, these 3 assays may not be useful for detecting violative antimicrobial residues in individual milk samples from cows treated for mild clinical mastitis. However, repeatability of each assay was considered good to excellent.
Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation.
Lahaije, Anke J M C; Willems, Laura M; van Hees, Hieronymus W H; Dekhuijzen, P N Richard; van Helvoort, Hanneke A C; Heijdra, Yvonne F
2013-01-01
This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this is assessed by measuring change in inspiratory capacity (IC) during cardiopulmonary exercise testing (CPET), which, however, is complex and laborious. Fifty-three patients with COPD (FEV(1) 58 ± 22%pred) and 20 age-matched healthy subjects were characterized by lung function testing and performed CPET (reference standard) and MPT. The repeatability coefficient of IC (10·2%) was used as cut-off to classify subjects as hyperinflators during CPET. Subsequently, dynamic hyperinflation was measured after MPT. With receiver operating characteristic analysis, the optimal cut-off for MPT-induced dynamic hyperinflation was determined and sensitivity and specificity of MPT to identify hyperinflators were evaluated. With 10·2% decrease in IC as cut-off for CPET-induced dynamic hyperinflation, the optimal cut-off for MPT was 11·1% decrease in IC. Using these cut-offs, MPT had a sensitivity of 85% and specificity of 85% to identify the subjects who hyperinflated during CPET. The MPT test shows good overall accuracy to identify subjects who are susceptible to develop dynamic hyperinflation during CPET. Before considering the use of MPT as a screening tool for dynamic hyperinflation in COPD, sensitivity and specificity need further evaluation. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.
Time-dependent pH sensing phenomena using CdSe/ZnS quantum dots in EIS structure.
Kumar, Pankaj; Maikap, Siddheswar; Prakash, Amit; Tien, Ta-Chang
2014-04-12
Time-dependent pH sensing phenomena of the core-shell CdSe/ZnS quantum dot (QD) sensors in EIS (electrolyte insulator semiconductor) structure have been investigated for the first time. The quantum dots are immobilized by chaperonin GroEL protein, which are observed by both atomic force microscope and scanning electron microscope. The diameter of one QD is approximately 6.5 nm. The QDs are not oxidized over a long time and core-shell CdSe/ZnS are confirmed by X-ray photon spectroscopy. The sensors are studied for sensing of hydrogen ions concentration in different buffer solutions at broad pH range of 2 to 12. The QD sensors show improved sensitivity (38 to 55 mV/pH) as compared to bare SiO2 sensor (36 to 23 mV/pH) with time period of 0 to 24 months, owing to the reduction of defects in the QDs. Therefore, the differential sensitivity of the QD sensors with respect to the bare SiO2 sensors is improved from 2 to 32 mV/pH for the time period of 0 to 24 months. After 24 months, the sensitivity of the QD sensors is close to ideal Nernstian response with good linearity of 99.96%. Stability and repeatability of the QD sensors show low drift (10 mV for 10 cycles) as well as small hysteresis characteristics (<10 mV). This QD sensor is very useful for future human disease diagnostics.
A FBG pulse wave demodulation method based on PCF modal interference filter
NASA Astrophysics Data System (ADS)
Zhang, Cheng; Xu, Shan; Shen, Ziqi; Zhao, Junfa; Miao, Changyun; Bai, Hua
2016-10-01
Fiber optic sensor embedded in textiles has been a new direction of researching smart wearable technology. Pulse signal which is generated by heart beat contains vast amounts of physio-pathological information about the cardiovascular system. Therefore, the research for textile-based fiber optic sensor which can detect pulse wave has far-reaching effects on early discovery and timely treatment of cardiovascular diseases. A novel wavelength demodulation method based on photonic crystal fiber (PCF) modal interference filter is proposed for the purpose of developing FBG pulse wave sensing system embedded in smart clothing. The mechanism of the PCF modal interference and the principle of wavelength demodulation based on In-line Mach-Zehnder interferometer (In-line MZI) are analyzed in theory. The fabricated PCF modal interferometer has the advantages of good repeatability and low temperature sensitivity of 3.5pm/°C from 25°C to 60°C. The designed demodulation system can achieve linear demodulation in the range of 2nm, with the wavelength resolution of 2.2pm and the wavelength sensitivity of 0.055nm-1. The actual experiments' result indicates that the pulse wave can be well detected by this demodulation method, which is in accordance with the commercial demodulation instrument (SM130) and more sensitive than the traditional piezoelectric pulse sensor. This demodulation method provides important references for the research of smart clothing based on fiber grating sensor embedded in textiles and accelerates the developments of wearable fiber optic sensors technology.
ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.
Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R
2018-01-01
The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Park, Albert H; Mann, David; Error, Marc E; Miller, Matthew; Firpo, Matthew A; Wang, Yong; Alder, Stephen C; Schleiss, Mark R
2013-01-01
To assess the validity of the guinea pig as a model for congenital cytomegalovirus (CMV) infection by comparing the effectiveness of detecting the virus by real-time polymerase chain reaction (PCR) in blood, urine, and saliva. Case-control study. Academic research. Eleven pregnant Hartley guinea pigs. Blood, urine, and saliva samples were collected from guinea pig pups delivered from pregnant dams inoculated with guinea pig CMV. These samples were then evaluated for the presence of guinea pig CMV by real-time PCR assuming 100% transmission. Thirty-one pups delivered from 9 inoculated pregnant dams and 8 uninfected control pups underwent testing for guinea pig CMV and for auditory brainstem response hearing loss. Repeated-measures analysis of variance demonstrated no statistically significantly lower weight for the infected pups compared with the noninfected control pups. Six infected pups demonstrated auditory brainstem response hearing loss. The sensitivity and specificity of the real-time PCR assay on saliva samples were 74.2% and 100.0%, respectively. The sensitivity of the real-time PCR on blood and urine samples was significantly lower than that on saliva samples. Real-time PCR assays of blood, urine, and saliva revealed that saliva samples show high sensitivity and specificity for detecting congenital CMV infection in guinea pigs. This finding is consistent with recent screening studies in human newborns. The guinea pig may be a good animal model in which to compare different diagnostic assays for congenital CMV infection.
Firefighter Safety Zone: The effect of terrain slope of separation distance
Bret Butler; Jason Forthofer
2010-01-01
Perhaps one of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and good judgement. The current safety zone guidelines used in the US (see fig. 1) and published in the...
Repeated injections of nicergoline increase the nerve growth factor level in the aged rat brain.
Nishio, T; Sunohara, N; Furukawa, S; Akiguchi, I; Kudo, Y
1998-03-01
We studied whether nicergoline, clinically active in chronic cerebrovascular insufficiency, influences nerve growth factor (NGF) levels in the rat brain. In young Fischer rats, repeated intraperitoneal injections of nicergoline (0.3 and 1.0 mg/kg body weight) did not show any effects on frontal NGF contents determined by a highly sensitive enzyme immunoassay. In aged rats, 22-month-old, however, repeated injections of nicergoline (1.0 mg/kg body weight) induced a significant increase in the NGF level in the frontal region.
Vanaveski, Taavi; Narvik, Jane; Innos, Jürgen; Philips, Mari-Anne; Ottas, Aigar; Plaas, Mario; Haring, Liina; Zilmer, Mihkel; Vasar, Eero
2018-01-01
The main goal of the study was to characterize the behavioral and metabolomic profiles of repeated administration (for 11 days) of d-amphetamine (AMPH, 3 mg/kg i. p.), indirect agonist of dopamine (DA), in widely used 129S6/SvEvTac (129Sv) and C57BL/6NTac (Bl6) mouse strains. Acute administration of AMPH (acute AMPH) induced significantly stronger motor stimulation in Bl6. However, repeated administration of AMPH (repeated AMPH) caused stronger motor sensitization in 129Sv compared acute AMPH. Body weight of 129Sv was reduced after repeated saline and AMPH, whereas no change occurred in Bl6. In the metabolomic study, acute AMPH induced an elevation of isoleucine and leucine, branched chain amino acids (BCAA), whereas the level of hexoses was reduced in Bl6. Both BCAAs and hexoses remained on level of acute AMPH after repeated AMPH in Bl6. Three biogenic amines [asymmetric dimethylarginine (ADMA), alpha-aminoadipic acid (alpha-AAA), kynurenine] were significantly reduced after repeated AMPH. Acute AMPH caused in 129Sv a significant reduction of valine, lysophosphatidylcholines (lysoPC a C16:0, lysoPC a C18:2, lysoPC a C20:4), phosphatidylcholine (PC) diacyls (PC aa C34:2, PC aa C36:2, PC aa C36:3, PC aa C36:4) and alkyl-acyls (PC ae C38:4, PC ae C40:4). However, repeated AMPH increased the levels of valine and isoleucine, long-chain acylcarnitines (C14, C14:1-OH, C16, C18:1), PC diacyls (PC aa C38:4, PC aa C38:6, PC aa C42:6), PC acyl-alkyls (PC ae C38:4, PC ae C40:4, PC ae C40:5, PC ae C40:6, PC ae C42:1, PC ae C42:3) and sphingolipids [SM(OH)C22:1, SM C24:0] compared to acute AMPH in 129Sv. Hexoses and kynurenine were reduced after repeated AMPH compared to saline in 129Sv. The established changes probably reflect a shift in energy metabolism toward lipid molecules in 129Sv because of reduced level of hexoses. Pooled data from both strains showed that the elevation of isoleucine and leucine was a prominent biomarker of AMPH-induced behavioral sensitization. Simultaneously a significant decline of hexoses, citrulline, ADMA, and kynurenine occurred. The reduced levels of kynurenine, ADMA, and citrulline likely reflect altered function of N-methyl-D-aspartate (NMDA) and NO systems caused by repeated AMPH. Altogether, 129Sv strain displays stronger sensitization toward AMPH and larger variance in metabolite levels than Bl6.
An electronic nose for reliable measurement and correct classification of beverages.
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.
Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi
2017-01-01
A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.
An Electronic Nose for Reliable Measurement and Correct Classification of Beverages
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964
Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L
2014-03-01
Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques. Copyright © 2013 Elsevier Inc. All rights reserved.
Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen
2012-07-01
A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.
Liu, Aihua; Lang, Qiaolin; Liang, Bo; Shi, Jianguo
2017-01-15
Glucoamylase-displayed bacteria (GA-bacteria) and glucose dehydrogenase-displayed bacteria (GDH-bacteria) were co-immobilized on multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (GCE) to construct GA-bacteria/GDH-bacteria/MWNTs/GCE biosensor. The biosensor was developed by optimizing the loading amount and the ratio of GA-bacteria to GDH-bacteria. The as-prepared biosensor exhibited a wide dynamic range of 0.2-10mM and a low detection limit of 0.1mM maltose (S/N=3). The biosensor also had a linear response to glucose in the range of 0.1-2.0mM and a low detection limit of 0.04mM glucose (S/N=3). Interestingly, at the same concentration, glucose was 3.75-fold sensitive than that of maltose at the proposed biosensor. No interferences were observed for other possible mono- and disaccharides. The biosensor also demonstrated good long-term storage stability and repeatability. Further, using both GDH-bacteria/MWNTs/GCE biosensor and GA-bacteria/GDH-bacteria/MWNTs/GCE biosensor, glucose and maltose in real samples can be detected. Therefore, the proposed biosensor is capable of monitoring the food manufacturing and fermentation process. Copyright © 2016 Elsevier B.V. All rights reserved.
Mendy, Alphonse; Thiaré, Diène Diégane; Sambou, Souleymane; Khonté, Abdourahmane; Coly, Atanasse; Gaye-Seye, Mame Diabou; Delattre, François; Tine, Alphonse
2016-05-01
Herbicide metolachlor (MET) and insecticide buprofezin (BUP) were determined in natural waters by means of a newly-developed, simple and sensitive thermochemically-induced fluorescence derivatization (TIFD) method. The TIFD approach is based on the thermolysis transformation of naturally non-fluorescent pesticides into fluorescent complex O-phthalaldehyde-thermoproduct(s) in water at 70°C for MET and at 80°C for BUP. The TIFD method was optimized with respect to the temperature, pH, complex formation kinetic and pesticides concentrations. The limit of detection (LOD=0.8ngmL(-1) for MET and 3.0ngmL(-1) for BUP) and quantification (LOQ=2.6ngmL(-1) for MET and 9.5 ngmL(-1) for BUP) values were low, and the relative standard deviation (RSD) values were small (between 1.2% and 1.8%), which indicates a good analytical sensitivity and a great repeatability of TIFD method. Recovery studies were performed on spiked well, sea and draining waters samples collected in the Niayes area by using the solid phase extraction (SPE) procedure. Satisfactory recovery results (84-118%) were obtained for the determination of MET and BUP in these natural waters. Copyright © 2016 Elsevier B.V. All rights reserved.
Development of a pH sensor using nanoporous nanostructures of NiO.
Ibupoto, Z H; Khun, K; Willander, M
2014-09-01
Glass is the conventional material used in pH electrodes to monitor pH in various applications. However, the glass-based pH electrode has some limitations for particular applications. The glass sensor is limited in the use of in vivo biomedical, clinical or food applications because of the brittleness of glass, its large size, the difficulty in measuring small volumes and the absence of deformation (inflexibility). Nanostructure-based pH sensors are very sensitive, reliable, fast and applicable towards in vivo measurements. In this study, nanoporous NiO nanostructures are synthesized on a gold-coated glass substrate by a hydrothermal route using poly(vinyl alcohol) (PVA) as a stabilizer. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques were used for the morphological and crystalline studies. The grown NiO nanostructures are uniform and dense, and they possess good crystallinity. A pH sensor based on these NiO nanostructures was developed by testing the different pH values from 2-12 of phosphate buffered saline solution. The proposed pH sensor showed robust sensitivity of -43.74 ± 0.80 mV/pH and a quick response time of less than 10 s. Moreover, the repeatability, reproducibility and stability of the presented pH sensor were also studied.
Chen, Nannan; Guo, Wenjing; Lin, Zhixiang; Wei, Qiaohua; Chen, Guonan
2018-08-01
A specific and label-free "on-off-on" luminescence biosensor based on a novel heterometallic cluster [Ag 6 Au 6 (ethisterone) 12 ]-estrogen receptor α (Ag 6 Au 6 Eth-ERα) aggregation utilizing graphene oxide (GO) as a quencher to lead a small background signal was firstly constructed to detect immunoglobulin G (IgG) with a simple process and high selectivity. The efficient photoluminescent (PL) Ag 6 Au 6 Eth-ERα aggregation is strongly quenched by GO. In the presence of IgG, the PL of this system will be restored, and perceivable by human eyes under UV lamp excitation (365 nm). The quenching mechanism of GO on Ag 6 Au 6 Eth-ERα and enhancement mechanism of IgG on Ag 6 Au 6 Eth-ERα-GO were investigated in detail. Under the optimum conditions, the biosensor for high sensitive IgG detection expressed a wider linear range of 0.0078-10 ng/mL and a lower detection limit of 0.65 pg/mL with good stability and repeatability, which provided a new approach for label-free IgG detection. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhao, Xian-En; Lv, Tao; Zhu, Shuyun; Qu, Fei; Chen, Guang; He, Yongrui; Wei, Na; Li, Guoliang; Xia, Lian; Sun, Zhiwei; Zhang, Shijuan; You, Jinmao; Liu, Shu; Liu, Zhiqiang; Sun, Jing; Liu, Shuying
2016-03-11
This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(S)-protopanaxadiol (PPD) and 20(S)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4'-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Ruina; Wang, Lili; Gao, Xiaotong; Du, Gangfeng; Zhai, Honglin; Wang, Xiayan; Guo, Guangsheng; Pu, Qiaosheng
2013-03-15
Rapid analysis of trace amount of aromatic amines in environmental samples and daily necessities has attracted considerable attentions because some of them are strongly toxic and carcinogenic. In this study, fast and efficient electrophoretic separation and sensitive determination of 5 banned aromatic amines were explored for practical analysis using disposable plastic microchips combined with a low-cost laser-induced fluorescence detector. The effect of running buffer and its additive was systematically investigated. Under the selected condition, 5 fluorescein isothiocyanate labeled aromatic amines could be baseline separated within 90s by using a 10mmol/L borate buffer containing 2% (w/v) hydroxypropyl cellulose. Calibration curves of peak areas vs. concentrations were linear up to 40 or 120μmol/L for different analytes and limits of detection were in a range of 1-3nmol/L. Theoretical plate numbers of 6.8-8.5×10(5)/m were readily achieved. The method exhibited good repeatability, relative standard deviations (n=5) of peak areas and migration times were no more than 4.6% and 0.9%, respectively. The established method was successfully applied in the quantitative analysis of these banned aromatic amines in real samples of waste water and textile, recoveries of added standards were 85-110%. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Almeida, F. L.; dos Santos Filho, S. G.; Fontes, M. B. A.
2013-03-01
The measurement of nitrite and its interfering-chemicals (paracetamol, ascorbic acid and uric acid) was performed employing a Flow-injection Analysis (FIA) system, which was automated using solenoid valves and air-pump. It is very important to quantify nitrite from river water, food and biologic fluids due to its antibacterial capacity in moderated concentrations, or its toxicity for human health even at low concentrations (> 20 μmol L-1 in blood fluids). Electrodes of the electrochemical planar sensor were defined by silk-screen technology. The measuring electrode was made from gold paste covered with 1-2 cis Diaminobenzene (DAB), which allowed good selectivity, linearity, repeatability, stability and optimized gain of sensitivity at 0.5 VAg/AgCl Nafion®117 (6.93 μA mol-1 L mm-2) compared to 0.3 VAg/AgCl Nafion® 117. The reference electrode was obtained from silver/palladium paste modified with chloride and covered with Nafion® 117. The auxiliary electrode was made from platinum paste. It was noteworthy that nitrite response adds to the response of the studied interfering-chemicals and it is predominant for concentrations lower than 175 μmol L-1.
ERIC Educational Resources Information Center
Levitan, Robert D.; Jansen, Pauline; Wendland, Barbara; Tiemeier, Henning; Jaddoe, Vincent W.; Silveira, Patricia P.; Kennedy, James L.; Atkinson, Leslie; Fleming, Alison; Sokolowski, Marla; Gaudreau, Helene; Steiner, Meir; Dubé, Laurette; Hamilton, Jill; Moss, Ellen; Wazana, Ashley; Meaney, Michael
2017-01-01
Background: Recent evidence suggests that early exposure to low maternal sensitivity is a risk factor for obesity in children and adolescents. A separate line of study shows that the seven-repeat (7R) allele of the dopamine-4 receptor gene (DRD4) increases susceptibility to environmental factors including maternal sensitivity. The current study…
Ringler, Adam; Holland, Austin; Wilson, David
2017-01-01
Variability in seismic instrumentation performance plays a fundamental role in our ability to carry out experiments in observational seismology. Many such experiments rely on the assumed performance of various seismic sensors as well as on methods to isolate the sensors from nonseismic noise sources. We look at the repeatability of estimating the self‐noise, midband sensitivity, and the relative orientation by comparing three collocated Nanometrics Trillium Compact sensors. To estimate the repeatability, we conduct a total of 15 trials in which one sensor is repeatedly reinstalled, alongside two undisturbed sensors. We find that we are able to estimate the midband sensitivity with an error of no greater than 0.04% with a 99th percentile confidence, assuming a standard normal distribution. We also find that we are able to estimate mean sensor self‐noise to within ±5.6 dB with a 99th percentile confidence in the 30–100‐s‐period band. Finally, we find our relative orientation errors have a mean difference in orientation of 0.0171° from the reference, but our trials have a standard deviation of 0.78°.
NASA Astrophysics Data System (ADS)
Pitman, Andrew J.; Yang, Zong-Liang; Henderson-Sellers, Ann
1993-10-01
The sensitivity of a land surface scheme to the distribution of precipitation within a general circulation model's grid element is investigated. Earlier experiments which showed considerable sensitivity of the runoff and evaporation simulation to the distribution of precipitation are repeated in the light of other results which show no sensitivity of evaporation to the distribution of precipitation. Results show that while the earlier results over-estimated the sensitivity of the surface hydrology to the precipitation distribution, the general conclusion that the system is sensitive is supported. It is found that changing the distribution of precipitation from falling over 100% of the grid square to falling over 10% leads to a reduction in evaporation from 1578 mm y-1 to 1195 mm y -1 while runoff increases from 278 mm y-1 to 602 mm y-1. The sensitivity is explained in terms of evaporation being dominated by available energy when precipitation falls over nearly the entire grid square, but by moisture availability (mainly intercepted water) when it falls over little of the grid square. These results also indicate that earlier work using stand-alone forcing to drive land surface schemes ‘off-line’, and to investigate the sensitivity of land surface codes to various parameters, leads to results which are non-repeatable in single column simulations.
Repeatability of measurements of removal of mite-infested brood to assess Varroa Sensitive Hygiene
USDA-ARS?s Scientific Manuscript database
Varroa Sensitive Hygiene is a useful resistance trait that bee breeders could increase in different populations with cost-effective and reliable tests. We investigated the reliability of a one-week test estimating the changes in infestation of brood introduced into highly selected and unselected co...
RIFM fragrance ingredient safety assessment, Isopulegol, CAS Registry Number 89-79-2.
Api, A M; Belsito, D; Bhatia, S; Bruze, M; Calow, P; Dagli, M L; Dekant, W; Fryer, A D; Kromidas, L; La Cava, S; Lalko, J F; Lapczynski, A; Liebler, D C; Penning, T M; Politano, V T; Ritacco, G; Salvito, D; Schultz, T W; Shen, J; Sipes, I G; Wall, B; Wilcox, D K
2016-11-01
This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data show that this material is not genotoxic nor does it have skin sensitization potential. The repeated dose, developmental and reproductive, and local respiratory toxicity endpoints were completed using the TTC (Threshold of Toxicological Concern) for a Cramer Class I material (0.03, 0.03 mg/kg/day and 1.4 mg/day, respectively). The phototoxicity/photoallergenicity endpoint was completed based on suitable UV spectra. The environmental endpoint was completed as described in the RIFM Framework. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mata, Jutta; Hogan, Candice L; Joormann, Jutta; Waugh, Christian E; Gotlib, Ian H
2013-02-01
Identifying factors that may protect individuals from developing Major Depressive Disorder (MDD) in the face of stress is critical. In the current study we experimentally tested whether such a potentially protective factor, engaging in acute exercise, reduces the adverse effects of repeated sad mood inductions in individuals who have recovered from depression. We hypothesized that recovered depressed participants who engage in acute exercise report a smaller increase in negative affect (NA) and a smaller decrease in positive affect (PA) when exposed to a repeated sad mood induction (i.e., habituation), whereas participants who do not exercise show sensitization (i.e., increased NA and decreased PA in response to a repeated adverse stimulus). Forty-one women recovered from MDD and 40 healthy control women were randomly assigned to either exercise for 15 minutes or quiet rest. Afterward, participants were exposed to two sad mood inductions and reported their levels of affect throughout the study. Recovered depressed participants who had not exercised exhibited higher NA after the second sad mood induction, a finding consistent with sensitization. In contrast, both recovered depressed participants who had engaged in acute exercise and healthy control participants showed no increase in NA in response to the repeated sad mood induction. Participants who exercised reported higher PA after the exercise bout; however, our hypothesis concerning reported PA trajectories following the sad mood inductions was not supported. Results suggest that exercise can serve as a protective factor in the face of exposure to repeated emotional stressors, particularly concerning NA in individuals who have recovered from depression. 2013 APA, all rights reserved
Acerbo, Martin J.; Johnson, Alan Kim
2011-01-01
Behavioral sensitization involves increases in the magnitude of a response to a stimulus after repeated exposures to the same response initiator. Administration of psychomotor stimulants and the induction of appetitive motivational states associated with natural reinforcers like sugar and salt are among experimental manipulations producing behavioral sensitization. In rats, repeated administration of the mineralocorticoid agonist deoxycorticosterone acetate (DOCA) initially induces incremental increases in daily hypertonic saline consumption (i.e., sensitization of sodium appetite) in spite of the retention of sodium. The present studies investigated whether sodium appetite sensitization induced by DOCA shares mechanisms similar to those of psychomotor stimulant-induced sensitization, and whether there is evidence for reciprocal cross-sensitization. In Experiments 1 and 3, rats received control or cocaine treatments to induce locomotor sensitization. A week later DOCA (or vehicle) was administered to generate a sodium appetite. Animals pretreated with cocaine showed a greater sodium appetite. In Experiment 2, the order of the putative sensitizing treatments was reversed. Rats first received either a series of DOCA or vehicle treatments either with or without access to saline and were later tested for sensitization of the locomotor response to cocaine. Animals pretreated with DOCA without access to saline showed greater locomotor responses to cocaine than animals receiving vehicle treatments. Together these experiments indicate that treatments generating a sustained salt appetite and producing cocaine-induced psychomotor responses show reciprocal behavioral cross-sensitization. The underlying mechanisms accounting for this relationship may be the fact that psychostimulants and an unresolved craving for sodium can act as potent stressors. PMID:21352848
Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei
2015-02-01
To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.
Morita, T; Nakamura, K; Osuga, T; Yokoyama, N; Khoirun, N; Morishita, K; Sasaki, N; Ohta, H; Takiguchi, M
2017-08-01
To assess the repeatability and characteristics of echocardiographic indices of the right ventricular (RV) function derived from speckle-tracking echocardiography. Fourteen laboratory Beagles and 103 privately owned dogs without cardiac disease were involved in this study. Right ventricular longitudinal strain, strain rate, and a strain-related index for assessing RV dyssynchrony derived from speckle-tracking echocardiography were obtained by two different observers using five Beagles. Within-day, between-day, and interobserver coefficients of variation and the intraclass correlation coefficient of speckle-tracking echocardiography indices were determined. Both speckle-tracking echocardiography and conventional indices of RV function, including the peak velocity of systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, fractional area change, and the Tei index, were obtained from 14 Beagles and 103 privately owned dogs. Relationships between echocardiographic indices and the body weight, heart rate, age, and sex were estimated by regression analysis. Speckle-tracking echocardiographic indices showed good within-day repeatability, between-day and interobserver repeatability were moderate to good. In large dogs, RV longitudinal strain, strain rate, and fractional area change were significantly decreased, while the index of RV dyssynchrony, systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, and the Tei index were increased. All speckle-tracking and conventional echocardiographic indices were correlated with the body weight. The speckle-tracking echocardiography indices were highly repeatable and body weight affected speckle-tracking echocardiography indices in dogs. Further studies are needed to apply speckle-tracking echocardiography indices in dogs with cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Repeatability and sensitivity of high resolution blood volume mapping in mouse kidney disease.
Wang, Feng; Jiang, Rosie T; Tantawy, Mohammed Noor; Borza, Dorin B; Takahashi, Keiko; Gore, John C; Harris, Raymond C; Takahashi, Takamune; Quarles, C Chad
2014-04-01
To evaluate the repeatability of MRI-derived relative blood volume (RBV) measurements in mouse kidneys across subjects and days and to evaluate sensitivity of this approach to renal pathology. A 7 Tesla MRI system and an intravascular iron-oxide contrast agent were used to acquire spin-echo-based renal RBV maps in 10 healthy mice on 2 consecutive days. Renal RBV maps were also acquired in the Alport and unilateral ureteral obstruction mouse models of renal disease. The average renal RBV measured on consecutive days was 19.97 ± 1.50 and 19.86 ± 1.62, yielding a concordance correlation coefficient of 0.94, indicating that this approach is highly repeatable. In the disease models, the RBV values were regionally dissimilar and substantially lower than those found in control mice. In vivo renal iron-oxide-based RBV mapping in mice complements the physiological information obtained from conventional assays of kidney function and could shed new insights into the pathological mechanisms of kidney disease. Copyright © 2013 Wiley Periodicals, Inc.
Enzyme-linked immunosorbent assay for diagnosis of Amphimerus spp. liver fluke infection in Humans
Cevallos, William; Calvopiña, Manuel; Nipáz, Victoria; Vicente-Santiago, Belén; López-Albán, Julio; Fernández-Soto, Pedro; Guevara, Ángel; Muro, Antonio
2017-01-01
BACKGROUND Amphimerus spp. is a liver fluke that infects humans and domestic animals. It is highly prevalent in some Ecuadorian communities. Currently, diagnosis is based on the microscopic observation of eggs in faeces, but this has variable sensitivity. More sensitive methods are needed for diagnostic testing. OBJECTIVE The main objective of this work was to develop an enzyme-linked immunosorbent assay (ELISA) using crude antigens from Amphimerus spp. adult worms to detect anti-Amphimerus IgG in human sera. METHODS Crude somatic antigens were obtained from adult Amphimerus spp. worms. Human sera from 119 patients were tested: 48 from individuals with a confirmed Amphimerus spp. infection, 78 from non-infected Ecuadorians living in the endemic region, 60 from persons living in non-endemic areas (20 Ecuadorians, 20 Europeans, and 20 Africans), and 33 who had other parasitic and non-parasitic infections. PRINCIPAL FINDINGS Results were analysed using the receiver-operator characteristic (ROC) curve analysis with an area under curve (AUC) value of 0.967. The accuracy of the ELISA was high. The sensitivity was 85.0% [95% confidence interval (CI): 80.3-89.7%] and the specificity was 71.0% (95% CI: 65.2-76.8%). Some cross reactivity was detected against Paragonimus mexicanus, Fasciola hepatica, Schistosomiasis, Taenia solium, Strongyloides stercoralis, Mansonella spp., and Vampirolepis nana. MAIN CONCLUSIONS We have developed the first ELISA technique that detects anti-Amphimerus IgG in human sera with good sensitivity, repeatability and reproducibility. However, more specific antigens are needed to further enhance performance of this assay. Regardless, this ELISA test could be useful for early diagnosis and prompt treatment of human Amphimerus spp. infections. PMID:28443982
Inhibitory control in young children and its role in emerging internalization.
Kochanska, G; Murray, K; Jacques, T Y; Koenig, A L; Vandegeest, K A
1996-04-01
We examined inhibitory control as a quality of temperament that contributes to internalization. Children were assessed twice, at 26-41 months (N = 103) and at 43-56 months (N = 99), on repeated occasions, in multiple observational contexts and using parental reports. Comprehensive behavioral batteries incorporating multiple tasks were designed to measure inhibitory control at toddler and preschool age. They had good internal consistencies, corresponded with maternal ratings, and were developmentally sensitive. Individual children's performance was significantly correlated across both assessments, indicating stable individual differences. Girls surpassed boys at both ages. Children's internalization was observed while they were alone with prohibited objects, with a mundane chore, playing games that occasioned cheating, being induced to violate standards of conduct, and assessed using maternal reports. Inhibitory control was significantly associated with internalization, both contemporaneously and as a predictor in the longitudinal sense. The implications for considering children's temperament as a significant, yet often neglected contributor to developing internalization are discussed.
Zhang, Lan; Tong, Ping; Chen, Guonan
2005-12-09
Aesculetin is the product of the hydrolysis reaction of aesculin. A high sensitivity and good repeatability method based on capillary electrophoresis with amperometric detection (CE-AD) was developed for simultaneous determination of aesculin and aesculetin in the hydrolysate of aesculin. Under the optimum condition: 10mmol/L KH(2)PO(4)-5mmol/L Na(2)B(4)O(7) (pH 6.0) buffer, separation at 18kV and +900mV (versus Ag/AgCl) as the detection potential, the hydrolysis rate constants of aesculin hydrolysis at 25, 30, 35, 40 and 45 degrees C in 0.1mol/L KOH were obtained as 1.45x10(-2)min(-1), 2.01x10(-2)min(-1), 2.93x10(-2)min(-1), 3.76x10(-2)min(-1) and 5.05x10(-2)min(-1), respectively. It was calculated that the activation energy for aesculin hydrolysis was 49.4kJ/mol.
NASA Astrophysics Data System (ADS)
Trojanova, E.; Jakubek, J.; Turecek, D.; Sykora, V.; Francova, P.; Kolarova, V.; Sefc, L.
2018-01-01
The imaging method of SPECT (Single Photon Emission Computed Tomography) is used in nuclear medicine for diagnostics of various diseases or organs malfunctions. The distribution of medically injected, inhaled, or ingested radionuclides (radiotracers) in the patient body is imaged using gamma-ray sensitive camera with suitable imaging collimator. The 3D image is then calculated by combining many images taken from different observation angles. Most of SPECT systems use scintillator based cameras. These cameras do not provide good energy resolution and do not allow efficient suppression of unwanted signals such as those caused by Compton scattering. The main goal of this work is evaluation of Timepix3 detector properties for SPECT method for functional imaging of small animals during preclinical studies. Advantageous Timepix3 properties such as energy and spatial resolution are exploited for significant image quality improvement. Preliminary measurements were performed on specially prepared plastic phantom with cavities filled by radioisotopes and then repeated with in vivo mouse sample.
Fluorescent carbon dots: facile synthesis at room temperature and its application for Fe2+ sensing
NASA Astrophysics Data System (ADS)
Xiao, Sai Jin; Chu, Zhao Jun; Zuo, Jun; Zhao, Xiao Jing; Huang, Cheng Zhi; Zhang, Li
2017-02-01
A new route for one-pot preparation of carbon dots (CDs) was developed at room temperature using PEG400 as both the carbon source and passitive agent. The new method possesses the advantages of facile, rapid, energy-saving, without any external stimulus and environment friendly. By changing the content of NaOH, the PEG400-CDs with blue-emitting, yellow-emitting, orange red-emitting and red-emitting were obtained, and the formation mechanism were carefully investigated. In addition, a sensitive fluorescence sensor were developed for Fe2+ detection based on PEG400-CDs since the fluorescence of PEG400-CDs could be enhanced by Fe2+. It was found that there is a good linear relationship between the enhanced fluorescence and Fe2+ concentration in the range of 0.5 to 2.0 μmol·L-1 with the detection limit of 6.0 × 10-8 mol·L-1, and Fe2+ in water samples was also determined with high accuracy and repeatability.
Huang, Xiaojia; Lin, Jianbin; Yuan, Dongxing; Hu, Rongzong
2009-04-17
In this study, a simple and rapid method was developed for the determination of seven steroid hormones in wastewater. Sample preparation and analysis were performed by stir bar sorptive extraction (SBSE) based on poly(vinylpyridine-ethylene dimethacrylate) monolithic material (SBSEM) combined with high-performance liquid chromatography with diode array detection. To achieve the optimum extraction performance, several main parameters, including extraction and desorption time, pH value and contents of inorganic salt in the sample matrix, were investigated. Under the optimized experimental conditions, the method showed good linearity and repeatability, as well as advantages such as sensitivity, simplicity, low cost and high feasibility. The extraction performance of SBSEM to the target compounds also compared with commercial SBSE which used polydimethylsiloxane as coating. Finally, the proposed method was successfully applied to the determination of the target compounds in wastewater samples. The recoveries of spiked target compounds in real samples ranged from 48.2% to 110%.
Improvement of up-converting phosphor technology-based biosensor
NASA Astrophysics Data System (ADS)
Xie, Chengke; Huang, Lihua; Zhang, Youbao; Guo, Xiaoxian; Qu, Jianfeng; Huang, Huijie
2008-12-01
A novel biosensor based on up-converting phosphor technology (UPT) was developed several years ago. It is a kind of optical biosensor using up-converting phosphor (UCP) particles as the biological marker. From then on, some improvements have been made for this UPT-based biosensor. The primary aspects of the improvement lie in the control system. On one hand, the hardware of the control system has been optimized, including replacing two single chip microcomputers (SCM) with only one, the optimal design of the keyboard interface circuit and the liquid crystal module (LCM) control circuit et al.. These result in lower power consumption and higher reliability. On the other hand, a novel signal processing algorithm is proposed in this paper, which can improve the automation and operating simplicity of the UPT-based biosensor. It has proved to have high sensitivity (~ng/ml), high stability and good repeatability (CV<5%), which is better than the former system. It can meet the need of some various applications such as rapid immunoassay, chemical and biological detection and so on.
NASA Astrophysics Data System (ADS)
Sakai, Takamasa; Kohno, Motohiro; Hirae, Sadao; Nakatani, Ikuyoshi; Kusuda, Tatsufumi
1993-09-01
In this paper, we discussed a novel approach to semiconductor surface inspection, which is analysis using the C--V curve measured in a noncontact method by the metal-air-semiconductor (MAIS) technique. A new gap sensing method using the so-called Goos-Haenchen effect was developed to achieve the noncontact C--V measurement. The MAIS technique exhibited comparable sensitivity and repeatability to those of conventional C--V measurement, and hence, good reproducibility and resolution for quantifying the electrically active impurity on the order of 1× 109/cm2, which is better than most spectrometric techniques, such as secondary ion mass spectroscopy (SIMS), electron spectroscopy for chemical analysis (ESCA) and Auger electron spectrocopy (AES) which are time-consuming and destructive. This measurement without preparation of any electrical contact metal electrode suggested, for the first time, the possibility of measuring an intrinsic characteristic of the semiconductor surface, using the examples of a concrete examination.
A Correction for IUE UV Flux Distributions from Comparisons with CALSPEC
NASA Astrophysics Data System (ADS)
Bohlin, Ralph C.; Bianchi, Luciana
2018-04-01
A collection of spectral energy distributions (SEDs) is available in the Hubble Space Telescope (HST) CALSPEC database that is based on calculated model atmospheres for pure hydrogen white dwarfs (WDs). A much larger set (∼100,000) of UV SEDs covering the range (1150–3350 Å) with somewhat lower quality are available in the IUE database. IUE low-dispersion flux distributions are compared with CALSPEC to provide a correction that places IUE fluxes on the CALSPEC scale. While IUE observations are repeatable to only 4%–10% in regions of good sensitivity, the average flux corrections have a precision of 2%–3%. Our re-calibration places the IUE flux scale on the current UV reference standard and is relevant for any project based on IUE archival data, including our planned comparison of GALEX to the corrected IUE fluxes. IUE SEDs may be used to plan observations and cross-calibrate data from future missions, so the IUE flux calibration must be consistent with HST instrumental calibrations to the best possible precision.
Scale factor measure method without turntable for angular rate gyroscope
NASA Astrophysics Data System (ADS)
Qi, Fangyi; Han, Xuefei; Yao, Yanqing; Xiong, Yuting; Huang, Yuqiong; Wang, Hua
2018-03-01
In this paper, a scale factor test method without turntable is originally designed for the angular rate gyroscope. A test system which consists of test device, data acquisition circuit and data processing software based on Labview platform is designed. Taking advantage of gyroscope's sensitivity of angular rate, a gyroscope with known scale factor, serves as a standard gyroscope. The standard gyroscope is installed on the test device together with a measured gyroscope. By shaking the test device around its edge which is parallel to the input axis of gyroscope, the scale factor of the measured gyroscope can be obtained in real time by the data processing software. This test method is fast. It helps test system miniaturized, easy to carry or move. Measure quarts MEMS gyroscope's scale factor multi-times by this method, the difference is less than 0.2%. Compare with testing by turntable, the scale factor difference is less than 1%. The accuracy and repeatability of the test system seems good.
Lefebvre, P; Agadir, A; Cornic, M; Gourmel, B; Hue, B; Dreux, C; Degos, L; Chomienne, C
1995-04-07
All-trans retinoic acid (all-trans RA), the active metabolite of vitamin A, has been demonstrated to be an efficient alternative to chemotherapy in the treatment of acute promyelocytic leukemia (APL), the AML3 subtype of the FAB cytological classification. Complete remission is obtained by inducing terminal granulocytic differentiation of the leukemic cells. To study all-trans RA pharmacokinetics in patients with APL, a rapid, precise and selective high-performance liquid chromatographic (HPLC) assay was developed. This method is easy and shows good repeatability (C.V. = 8.41-12.44%), reproducibility (C.V. = 9.19-14.73%), accuracy (C.V. = 3.5-11%) and sensitivity with a detection limit of 5 pmol/ml. The analysis is performed using normal-phase HPLC in an isocratic mode with UV detection after solid-phase extraction on octadecyl (C18) columns. The mobile phase is hexane-dichloromethane-dioxane (78:18:4, v/v) containing 1% acetic acid.
EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.
2013-01-01
Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049
USE OF DIAGNODENT® FOR DIAGNOSIS OF NON-CAVITATED OCCLUSALDENTIN CARIES
Costa, Ana Maria; de Paula, Lilian Marly; Bezerra, Ana Cristina Barreto
2008-01-01
The purpose of this study was to evaluate the use of a laser fluorescence device for detection of occlusal caries in permanent teeth. One hundred and ninety-nine non-cavitated teeth from 26 patients aged 10 to 13 years were selected. After dental prophylaxis, two previously calibrated dentists examined the teeth. Visual inspection, radiographic examination and laser measurements were performed under standardized conditions. The validation method was cavity preparation with a small cone-shaped diamond bur, when the two examiners agreed about the presence of dentin caries. It was found that the laser detection method produced high values of sensitivity (0.93) and specificity (0.75) and a moderate positive predictive value (0.63). The laser device showed the lowest value of likelihood ratio (3.68). Kappa coefficient showed good repeatability for all methods. Although the laser device had an acceptable performance, this equipment should be used as an adjunct method to visual inspection to avoid false positive results. PMID:19089284
Natural oxygenation of Champagne wine during ageing on lees: A metabolomics picture of hormesis.
Roullier-Gall, Chloé; Witting, Michael; Moritz, Franco; Gil, Ryan B; Goffette, Delphine; Valade, Michel; Schmitt-Kopplin, Philippe; Gougeon, Régis D
2016-07-15
The oxygenation of Champagne wine after 4 and 6 years of aging on lees in bottle was investigated by FTICR-MS and UPLC-Q-TOF-MS. Three levels of permeability were considered for the stoppers, ranging from 0.2 to 1.8 mg/L/year of oxygen transfer rate. Our results confirmed a good repeatability of ultra-high resolution FTICR-MS, both in terms of m/z and coefficient of variation of peak intensities among biological replicates. Vintages appeared to be the most discriminated features, and metabolite annotations suggested that the oldest wines (2006) were characterized by a higher sensitivity towards oxygenation. Within each vintage, the oxygenation mechanisms appeared to be different for low and high ingresses of oxygen, in agreement with the hormesis character of wine oxygenation. In the particular case of single variety wines and for a given level of stopper permeability, our results also showed that variety discrimination could be easily achieved among wines. Copyright © 2016 Elsevier Ltd. All rights reserved.
Real-time biodetection using a smartphone-based dual-color surface plasmon resonance sensor
NASA Astrophysics Data System (ADS)
Liu, Qiang; Yuan, Huizhen; Liu, Yun; Wang, Jiabin; Jing, Zhenguo; Peng, Wei
2018-04-01
We proposed a compact and cost-effective red-green dual-color fiber optic surface plasmon resonance (SPR) sensor based on the smartphone. Inherent color selectivity of phone cameras was utilized for real-time monitoring of red and green color channels simultaneously, which can reduce the chance of false detection and improve the sensitivity. Because there are no external prisms, complex optical lenses, or diffraction grating, simple optical configuration is realized. It has a linear response in a refractive index range of 1.326 to 1.351 (R2 = 0.991) with a resolution of 2.3 × 10 - 4 RIU. We apply it for immunoglobulin G (IgG) concentration measurement. Experimental results demonstrate that a linear SPR response was achieved for IgG concentrations varying from 0.02 to 0.30 mg / ml with good repeatability. It may find promising applications in the fields of public health and environment monitoring owing to its simple optics design and applicability in real-time, label-free biodetection.
Zheng, Zhi; Gan, Lin; Zhang, Jianbing; Zhuge, Fuwei; Zhai, Tianyou
2017-03-01
ZnO nanostructure-based photodetectors have a wide applications in many aspects, however, the response range of which are mainly restricted in the UV region dictated by its bandgap. Herein, UV-vis-NIR sensitive ZnO photodetectors consisting of ZnO nanowires (NW) array/PbS quantum dots (QDs) heterostructures are fabricated through modified electrospining method and an exchanging process. Besides wider response region compared to pure ZnO NWs based photodetectors, the heterostructures based photodetectors have faster response and recovery speed in UV range. Moreover, such photodetectors demonstrate good flexibility as well, which maintain almost constant performances under extreme (up to 180°) and repeat (up to 200 cycles) bending conditions in UV-vis-NIR range. Finally, this strategy is further verified on other kinds of 1D nanowires and 0D QDs, and similar enhancement on the performance of corresponding photodetecetors can be acquired, evidencing the universality of this strategy.
NASA Astrophysics Data System (ADS)
Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il
2008-11-01
Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.
Zhou, Shaofeng; Han, Xiaojuan; Fan, Honglei; Liu, Yaqing
2016-06-22
Au nanoparticles decorated mesoporous MnFe₂O₄ nanocrystal clusters (MnFe₂O₄/Au hybrid nanospheres) were used for the electrochemical sensing of As(III) by square wave anodic stripping voltammetry (SWASV). Modified on a cheap glass carbon electrode, these MnFe₂O₄/Au hybrid nanospheres show favorable sensitivity (0.315 μA/ppb) and limit of detection (LOD) (3.37 ppb) toward As(III) under the optimized conditions in 0.1 M NaAc-HAc (pH 5.0) by depositing for 150 s at the deposition potential of -0.9 V. No obvious interference from Cd(II) and Hg(II) was recognized during the detection of As(III). Additionally, the developed electrode displayed good reproducibility, stability, and repeatability, and offered potential practical applicability for electrochemical detection of As(III) in real water samples. The present work provides a potential method for the design of new and cheap sensors in the application of electrochemical determination toward trace As(III) and other toxic metal ions.
Fang, Ching; Chung, Yu-Lin; Liu, Ju-Tsung; Lin, Cheng-Huang
2002-02-18
Because of the increasing use of 3,4-methylenedioxymethamphetamine (3,4-MDMA), a rapid and sensitive analytical technique is required for its detection and determination. Using nonaqueous capillary electrophoresis/fluorescence spectroscopy (NACE/FS) detection, it is possible to determine this drug at the level 0.5 ppm without any pre-treatment in less than 5 min. After liquid-liquid extraction, the sample can be condensed and a detection limit of 3,4-MDMA in urine of 50 ppb (S/N = 3) can be achieved. The precision of the method was evaluated by measuring the repeatability and intermediate precision of migration time and the corrected peak height by comparison with a 3,4-MDMA-D5 internal standard. With the conventional GC/MS method, it is necessary to derivatize the 3,4-MDMA before injection and the GC migration time also is in excess of 20 min. Therefore, NACE/FS represents a good complementary method to GC/MS for use in forensic analysis.
NASA Technical Reports Server (NTRS)
Ferri, A.; Roffe, G.
1975-01-01
A series of experiments were performed to evaluate the effectiveness of a three-dimensional land and groove wall geometry and a variable permeability distribution to reduce the interference produced by the porous walls of a supercritical transonic test section. The three-dimensional wall geometry was found to diffuse the pressure perturbations caused by small local mismatches in wall porosity permitting the use of a relatively coarse wall porosity control to reduce or eliminate wall interference effects. The wall porosity distribution required was found to be a sensitive function of Mach number requiring that the Mach number repeatability characteristics of the test apparatus be quite good. The effectiveness of a variable porosity wall is greatest in the upstream region of the test section where the pressure differences across the wall are largest. An effective variable porosity wall in the down stream region of the test section requires the use of a slightly convergent test section geometry.
Metal organic frameworks enhanced graphene oxide electrode for humidity sensor
NASA Astrophysics Data System (ADS)
Zhang, Wen; Meng, Siyu; Wang, Hui; He, Yongning
2018-03-01
Copper benzene-1,3,5-tricarboxylate (Cu-BTC), a typical metal organic framework, is deposited on the graphene oxide (GO) film to prepare a resistance humidity sensor (Cu- BTC/GO) for improving humidity sensing. The characteristics of Cu-BTC, GO and Cu- BTC/GO were measured by scanning electron microscopy (SEM), X-ray diffraction (XRD), nitrogen isotherm adsorption and electrochemical impedance spectroscopy (EIS). The humidity sensing properties of the Cu-BTC/GO were investigated in detail. The obtained Cu-BTC/GO demonstrates good sensitivity and repeatability over 11%-85% relative humidity (RH) measurements. The Cu-BTC/GO coated device shows high normalized response (S) value (6200%), which is much higher than that of pure GO coated device. Sensing mechanism of Cu- BTC/GO is discussed based on different RH and the results indicate that moderate amounts of Cu-BTC deposition can enhance sensing abilities of GO. High specific surface area and interfacial conductivity are crucial factors to fabricate humidity sensors with high performance.
Kobluk, C N; Schnurr, D; Horney, F D; Sumner-Smith, G; Willoughby, R A; Dekleer, V; Hearn, T C
1989-01-01
High-speed cinematography with computer aided analysis was used to study equine hindlimb kinematics. Eight horses were filmed at the trot or the pace. Filming was done from the side (lateral) and the back (caudal). Parameters measured from the lateral filming included the heights of the tuber coxae and tailhead, protraction and retraction of the hoof and angular changes of the tarsus and stifle. Abduction and adduction of the limb and tarsal height changes were measured from the caudal filming. The maximum and minimum values plus the standard deviations and coefficients of variations are presented in tabular form. Three gait diagrams were constructed to represent stifle angle versus tarsal angle, metatarsophalangeal height versus protraction-retraction (fetlock height diagram) and tuber coxae and tailhead height versus stride (pelvic height diagram). Application of the technique to the group of horses revealed good repeatability of the gait diagrams within a limb and the diagrams appeared to be sensitive indicators of left/right asymmetries.
A portable analyser for the measurement of ammonium in marine waters.
Amornthammarong, Natchanon; Zhang, Jia-Zhong; Ortner, Peter B; Stamates, Jack; Shoemaker, Michael; Kindel, Michael W
2013-03-01
A portable ammonium analyser was developed and used to measure in situ ammonium in the marine environment. The analyser incorporates an improved LED photodiode-based fluorescence detector (LPFD). This system is more sensitive and considerably smaller than previous systems and incorporates a pre-filtering subsystem enabling measurements in turbid, sediment-laden waters. Over the typical range for ammonium in marine waters (0–10 mM), the response is linear (r(2) = 0.9930) with a limit of detection (S/N ratio > 3) of 10 nM. The working range for marine waters is 0.05–10 mM. Repeatability is 0.3% (n =10) at an ammonium level of 2 mM. Results from automated operation in 15 min cycles over 16 days had good overall precision (RSD = 3%, n = 660). The system was field tested at three shallow South Florida sites. Diurnal cycles and possibly a tidal influence were expressed in the concentration variability observed.
Charge modeling of ionic polymer-metal composites for dynamic curvature sensing
NASA Astrophysics Data System (ADS)
Bahramzadeh, Yousef; Shahinpoor, Mohsen
2011-04-01
A curvature sensor based on Ionic Polymer-Metal Composite (IPMC) is proposed and characterized for sensing of curvature variation in structures such as inflatable space structures in which using low power and flexible curvature sensor is of high importance for dynamic monitoring of shape at desired points. The linearity of output signal of sensor for calibration, effect of deflection rate at low frequencies and the phase delay between the output signal and the input deformation of IPMC curvature sensor is investigated. An analytical chemo-electro-mechanical model for charge dynamic of IPMC sensor is presented based on Nernst-Planck partial differential equation which can be used to explain the phenomena observed in experiments. The rate dependency of output signal and phase delay between the applied deformation and sensor signal is studied using the proposed model. The model provides a background for predicting the general characteristics of IPMC sensor. It is shown that IPMC sensor exhibits good linearity, sensitivity, and repeatability for dynamic curvature sensing of inflatable structures.
Qu, Jianying; Dong, Ying; Yong, Wang; Lou, Tongfang; Du, Xueping; Qu, Jianhang
2016-03-01
Fe3O4 magnetic nanoparticles were synthesized by chemical co-precipitation with sodium citrate as surfactant and were characterized by FT-IR spectrometer, X-ray diffraction and transmission electron microscopy. A novel nitrite sensor was fabricated by electropolymerization of alizarin red on the surface of glassy carbon electrode modified with Fe3O4-multiwalled carbon nanotubes composite nanofilm. Under the optimal experimental conditions, it was showed that the proposed sensor exhibited good electrocatalytic activity to the oxidation of nitrite, and the peak current increased linearly with the nitrite concentration from 9.64 x 10(-6) mol x L(-1) to 1.30 x 10(-3) mol x L(-1) (R = 0.9976) with a detection limit of 1.19 x 10(-6) mol x L(-1) (S/N = 3). This sensor showed excellent sensitivity, wide linear range, stability and repeatability for nitrite determination with potential applications.
The Beauty of the Acronym!: "Good Management Begins with Good People"
ERIC Educational Resources Information Center
Vicars, Dennis
2010-01-01
Acronyms are not only short and catchy, but they may also help one to quickly hone in on what's important and to set priorities. In a field that seems to bask in process, over-analysis, and repeated discussion, the acronym "cuts to the chase" and keeps everyone on the same page. The last Management Maxim column ("Exchange," March/April 2010)…
Fischer, A; Luginbühl, T; Delattre, L; Delouard, J M; Faverdin, P
2015-07-01
Body condition is an indirect estimation of the level of body reserves, and its variation reflects cumulative variation in energy balance. It interacts with reproductive and health performance, which are important to consider in dairy production but not easy to monitor. The commonly used body condition score (BCS) is time consuming, subjective, and not very sensitive. The aim was therefore to develop and validate a method assessing BCS with 3-dimensional (3D) surfaces of the cow's rear. A camera captured 3D shapes 2 m from the floor in a weigh station at the milking parlor exit. The BCS was scored by 3 experts on the same day as 3D imaging. Four anatomical landmarks had to be identified manually on each 3D surface to define a space centered on the cow's rear. A set of 57 3D surfaces from 56 Holstein dairy cows was selected to cover a large BCS range (from 0.5 to 4.75 on a 0 to 5 scale) to calibrate 3D surfaces on BCS. After performing a principal component analysis on this data set, multiple linear regression was fitted on the coordinates of these surfaces in the principal components' space to assess BCS. The validation was performed on 2 external data sets: one with cows used for calibration, but at a different lactation stage, and one with cows not used for calibration. Additionally, 6 cows were scanned once and their surfaces processed 8 times each for repeatability and then these cows were scanned 8 times each the same day for reproducibility. The selected model showed perfect calibration and a good but weaker validation (root mean square error=0.31 for the data set with cows used for calibration; 0.32 for the data set with cows not used for calibration). Assessing BCS with 3D surfaces was 3 times more repeatable (standard error=0.075 versus 0.210 for BCS) and 2.8 times more reproducible than manually scored BCS (standard error=0.103 versus 0.280 for BCS). The prediction error was similar for both validation data sets, indicating that the method is not less efficient for cows not used for calibration. The major part of reproducibility error incorporates repeatability error. An automation of the anatomical landmarks identification is required, first to allow broadband measures of body condition and second to improve repeatability and consequently reproducibility. Assessing BCS using 3D imaging coupled with principal component analysis appears to be a very promising means of improving precision and feasibility of this trait measurement. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Muleme, Michael; Stenos, John; Vincent, Gemma; Campbell, Angus; Graves, Stephen; Warner, Simone; Devlin, Joanne M; Nguyen, Chelsea; Stevenson, Mark A; Wilks, Colin R; Firestone, Simon M
2016-06-01
Although many studies have reported the indirect immunofluorescence assay (IFA) to be more sensitive in detection of antibodies to Coxiella burnetii than the complement fixation test (CFT), the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the assay have not been previously established for use in ruminants. This study aimed to validate the IFA by describing the optimization, selection of cutoff titers, repeatability, and reliability as well as the DSe and DSp of the assay. Bayesian latent class analysis was used to estimate diagnostic specifications in comparison with the CFT and the enzyme-linked immunosorbent assay (ELISA). The optimal cutoff dilution for screening for IgG and IgM antibodies in goat serum using the IFA was estimated to be 1:160. The IFA had good repeatability (>96.9% for IgG, >78.0% for IgM), and there was almost perfect agreement (Cohen's kappa > 0.80 for IgG) between the readings reported by two technicians for samples tested for IgG antibodies. The IFA had a higher DSe (94.8%; 95% confidence interval [CI], 80.3, 99.6) for the detection of IgG antibodies against C. burnetii than the ELISA (70.1%; 95% CI, 52.7, 91.0) and the CFT (29.8%; 95% CI, 17.0, 44.8). All three tests were highly specific for goat IgG antibodies. The IFA also had a higher DSe (88.8%; 95% CI, 58.2, 99.5) for detection of IgM antibodies than the ELISA (71.7%; 95% CI, 46.3, 92.8). These results underscore the better suitability of the IFA than of the CFT and ELISA for detection of IgG and IgM antibodies in goat serum and possibly in serum from other ruminants. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kayem, Gilles; Batteux, Frederic; Girard, Noémie; Schmitz, Thomas; Willaime, Marion; Maillard, Francoise; Jarreau, Pierre Henri; Goffinet, Francois
2017-04-01
Examine the predictive value for maternal-fetal infection of routine bedside tests detecting the proinflammatory cytokines, TNFα and IL-6, in the vaginal secretions of women with premature rupture of the membranes (PROM). This prospective two-center cohort study included all women hospitalized for PROM over a 2-year period. A bedside test assessed IL-6 and TNFα in vaginal secretions. Both centers routinely tested CRP and leukocytes, assaying both in maternal serum, and analyzed vaginal bacterial flora; all samples were repeated twice weekly until delivery. The study included 689 women. In cases of preterm PROM (PPROM) before 37 weeks (n=184), a vaginal sample positive for one or more bacteria was the only marker associated with early neonatal infection (OR 5.6, 95%CI; 2.0-15.7). Its sensitivity was 82% (95%CI; 62-94) and its specificity 56% (95%CI; 47-65). All positive markers of infection were associated with the occurrence of chorioamnionitis. In cases of PROM from 37 weeks onward (n=505), only CRP >5mg/dL was associated with early neonatal infection (OR=8.3, 95%CI; 1.1-65.4) or clinical chorioamnionitis (OR=6.8, 95%CI; 1.5-30.0). The sensitivity of CRP >5mg/dL was 91% (95%CI; 59-100) and its specificity 45% (95%CI; 40-51) for predicting early neonatal infection, and 89% (95%CI; 65-99) and 46% (95%CI; 41-51), respectively, for predicting clinical chorioamnionitis. The association of vaginal cytokines with maternal-fetal infection is weak and thus prevents their use as a good predictor of maternal-fetal infection. CRP and vaginal samples may be useful for identifying a group of women at low risk of infection. Copyright © 2017 Elsevier B.V. All rights reserved.
Stenos, John; Vincent, Gemma; Campbell, Angus; Graves, Stephen; Warner, Simone; Devlin, Joanne M.; Nguyen, Chelsea; Stevenson, Mark A.; Wilks, Colin R.; Firestone, Simon M.
2016-01-01
Although many studies have reported the indirect immunofluorescence assay (IFA) to be more sensitive in detection of antibodies to Coxiella burnetii than the complement fixation test (CFT), the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the assay have not been previously established for use in ruminants. This study aimed to validate the IFA by describing the optimization, selection of cutoff titers, repeatability, and reliability as well as the DSe and DSp of the assay. Bayesian latent class analysis was used to estimate diagnostic specifications in comparison with the CFT and the enzyme-linked immunosorbent assay (ELISA). The optimal cutoff dilution for screening for IgG and IgM antibodies in goat serum using the IFA was estimated to be 1:160. The IFA had good repeatability (>96.9% for IgG, >78.0% for IgM), and there was almost perfect agreement (Cohen's kappa > 0.80 for IgG) between the readings reported by two technicians for samples tested for IgG antibodies. The IFA had a higher DSe (94.8%; 95% confidence interval [CI], 80.3, 99.6) for the detection of IgG antibodies against C. burnetii than the ELISA (70.1%; 95% CI, 52.7, 91.0) and the CFT (29.8%; 95% CI, 17.0, 44.8). All three tests were highly specific for goat IgG antibodies. The IFA also had a higher DSe (88.8%; 95% CI, 58.2, 99.5) for detection of IgM antibodies than the ELISA (71.7%; 95% CI, 46.3, 92.8). These results underscore the better suitability of the IFA than of the CFT and ELISA for detection of IgG and IgM antibodies in goat serum and possibly in serum from other ruminants. PMID:27122484
Coevolutionary dynamics of aspiration and strategy in spatial repeated public goods games
NASA Astrophysics Data System (ADS)
Wu, Te; Fu, Feng; Wang, Long
2018-06-01
The evolutionary dynamics remain largely unknown for spatial populations where individuals are more likely to interact repeatedly. Under this settings, individuals can make their decisions to cooperate or not based on the decisions previously adopted by others in their neighborhoods. Using repeated public goods game, we construct a spatial model and use a statistical physics approach to study the coevolutionary dynamics of aspiration and strategy. Individuals each have an aspiration towards the groups they are involved. According to the outcome of each group, individuals have assessment of whether their aspirations are satisfied. If satisfied, they cooperate next round. Otherwise, they switch to defecting. Results show threshold phenomenon for harsh collective dilemma: cooperators sticking to high levels of aspiration can prevail over defectors, while cooperators with other levels are invariably wiped out. When the collective dilemma is relaxed, cooperation is greatly facilitated by inducing a high level of diversity of aspiration. Snapshots further show the spatial patterns of how this coevolutionary process leads to the emergence of an optimal solution associated with aspiration level, whose corresponding strategy are most prevalent. This optimal solution lies in one and the highest aspiration level allowed, and depends on the intensity of the social dilemma. By removing the memory effect, our results also confirm that repeated interactions can promote cooperation, but to a limited degree.
Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter
Venkataraman, Arvind; Mardi, Sapna K; Pillai, Sarita
2010-01-01
Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32mm (SD) with the Orbscan and 11.92 ± 0.33mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan. PMID:20413925
Schnuch, Axel; Uter, Wolfgang; Dickel, Heinrich; Szliska, Christiane; Schliemann, Sibylle; Eben, Ricarda; Ruëff, Franziska; Gimenez-Arnau, Ana; Löffler, Harald; Aberer, Werner; Frambach, Yvonne; Worm, Margitta; Niebuhr, Margarete; Hillen, Uwe; Martin, Vera; Jappe, Uta; Frosch, Peter J; Mahler, Vera
2009-09-01
To identify the concentration of the fragrance compound hydroxyisohexyl 3-cyclohexene carboxaldehyde (INCI) (HICC) that is sufficiently low not to cause an allergic reaction in patients with proven sensitization. Repeated open application testing (ROAT) in 64 subjects with 2 preparations (perfume and cream) in different concentration (0.005-2.5%). Confirmatory patch testing with four preparations in two different concentrations (2.5% and 5%). The concentrations of HICC being tolerated by 90% of those sensitized to HICC are estimated as <88.2 ppm (cream) and <270 ppm (perfume) equivalent to 1.2 microg/cm(2) (perfume) and 4.9 microg/cm(2) (cream). Patch test preparations differed with regard to sensitivity (88.5-98.1%) and specificity (37.5-87.5%) against the ROAT result as external criterion. ROAT concentrations and the reaction strength in patch testing were inversely correlated (Kendall's tau-b: 0.69), both indicating the existence of different degrees of susceptibility. To protect 90% (50%) of people sensitized, the use concentration should be in the range of 0.009-0.027% (0.18-0.34%), depending on the product type. Taking into account these results, excessive concentrations should be avoided, as this would continue to sensitize people. Close monitoring is indispensable to prove the efficacy of any recommendations aiming to prevent induction.
Analysis of cyanide in whole blood of dosed cathartids
Krynitsky, A.J.; Wiemeyer, Stanley N.; Hill, E.F.; Carpenter, J.W.
1986-01-01
A gas-liquid chromatographic method was modified to quantify both unmetabolized ('free') and metabolized ('bound', i.e., thiocyanates) cyanides. The methods for both are efficient and sensitive to 0.05 ppm. Repeated freezing and thawing of whole blood from treated cathartids caused an initial increase in free cyanide concentrations, followed by a gradual decline to a plateau. Bound cyanide concentrations declined after repeated freezing and thawing.
2016-04-01
environment. Modeling is suitable for well- characterized parts, and stochastic modeling techniques can be used for sensitivity analysis and generating a...large cohort of trials to spot unusual cases. However, deployment repeatability is inherently a nonlinear phenomenon, which makes modeling difficult...recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the U.S. Air Force. 1. Test the flight model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adekunle, S.S.A.; Wyandt, H.; Mark, H.F.L.
1994-09-01
Recently we mapped the telomeric repeat sequences to 111 interstitial sites in the human genome and to sites of gaps and breaks induced by aphidicolin and sister chromatid exchange sites detected by BrdU. Many of these sites correspond to conserved fragile sites in man, gorilla and chimpazee, to sites of conserved sister chromatid exchange in the mammalian X chromosome, to mutagenic sensitive sites, mapped locations of proto-oncogenes, breakpoints implicated in primate evolution and to breakpoints indicated as the sole anomaly in neoplasia. This observation prompted us to investigate if the interstitial telomeric sites cluster with these sites. An extensive literaturemore » search was carried out to find all the available published sites mentioned above. For comparison, we also carried out a statistical analysis of the clustering of the sites of the telomeric repeats with the gene locations where only nucleotide mutations have been observed as the only chromosomal abnormality. Our results indicate that the telomeric repeats cluster most with fragile sites, mutagenic sensitive sites and breakpoints implicated in primate evolution and least with cancer breakpoints, mapped locations of proto-oncogenes and other genes with nucleotide mutations.« less
Clostridium difficile Infection
... These drugs can make your infection worse. Certain probiotics, or “good bacteria,” may help prevent repeat C. ... Your Doctor Drugs, Procedures & Devices Over-the-counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom ...
The human genome as "common good".
Vesto, Aurora
2017-07-01
Objectivity of rights must be rebuilt in a dimension not only structural but also functional, despite being a "thing" that exactly repeats itself, it differs depending on what the person intended to make.
Blanco, Eduardo; Galeano, Pablo; Palomino, Ana; Pavón, Francisco J; Rivera, Patricia; Serrano, Antonia; Alen, Francisco; Rubio, Leticia; Vargas, Antonio; Castilla-Ortega, Estela; Decara, Juan; Bilbao, Ainhoa; de Fonseca, Fernando Rodríguez; Suárez, Juan
2016-03-01
In the reward mesocorticolimbic circuits, the glutamatergic and endocannabinoid systems are implicated in neurobiological mechanisms underlying cocaine addiction. However, the involvement of both systems in the hippocampus, a critical region to process relational information relevant for encoding drug-associated memories, in cocaine-related behaviors remains unknown. In the present work, we studied whether the hippocampal gene/protein expression of relevant glutamate signaling components, including glutamate-synthesizing enzymes and metabotropic and ionotropic receptors, and the hippocampal gene/protein expression of cannabinoid type 1 (CB1) receptor and endocannabinoid metabolic enzymes were altered following acute and/or repeated cocaine administration resulting in conditioned locomotion and locomotor sensitization. Results showed that acute cocaine administration induced an overall down-regulation of glutamate-related gene expression and, specifically, a low phosphorylation level of GluA1. In contrast, locomotor sensitization to cocaine produced an up-regulation of several glutamate receptor-related genes and, specifically, an increased protein expression of the GluN1 receptor subunit. Regarding the endocannabinoid system, acute and repeated cocaine administration were associated with an increased gene/protein expression of CB1 receptors and a decreased gene/protein expression of the endocannabinoid-synthesis enzymes N-acyl phosphatidylethanolamine D (NAPE-PLD) and diacylglycerol lipase alpha (DAGLα). These changes resulted in an overall decrease in endocannabinoid synthesis/degradation ratios, especially NAPE-PLD/fatty acid amide hydrolase and DAGLα/monoacylglycerol lipase, suggesting a reduced endocannabinoid production associated with a compensatory up-regulation of CB1 receptor. Overall, these findings suggest that repeated cocaine administration resulting in locomotor sensitization induces a down-regulation of the endocannabinoid signaling that could contribute to the specifically increased GluN1 expression observed in the hippocampus of cocaine-sensitized mice. Copyright © 2016 Elsevier B.V. and ECNP. All rights reserved.
Bowen, Scott E; Balster, Robert L
2006-05-01
1,1,1-Trichloroethane (TCE), a representative abused solvent, has well described acute behavioral effects in animals. Much less is known about repeated high-concentration exposures as would be encountered in inhalant abusers. Tolerance has been demonstrated in some, but not all, studies with TCE while sensitization has also been seen with other abused solvents. The present study was designed to further characterize changes in the effects of repeated exposure to TCE on a variety of mouse behaviors. Mice were tested using locomotor activity as well as a functional observational battery (FOB) both before and after a regimen of daily exposures to various concentrations of TCE. The initial locomotor effects of acute 30-min exposures to TCE were biphasic with concentration-dependent increases in activity at lower concentrations and decreases observed at higher concentrations. The profile of acute effects as measured by the FOB included changes in posture, decreased arousal, disturbances in gait, delayed righting reflexes, and decreased sensorimotor reactivity. Animals were then divided into five groups and exposed 30 min/day to either air or one of four concentrations of TCE (2,000, 6,000, 10,000, or 13,300 ppm) for 15 consecutive days. The TCE concentration used primarily affected the magnitude of change, not whether tolerance or sensitization occurred. Tolerance developed on the measures of forelimb grip strength, inverted screen, and number of rears. Conversely, sensitization developed to measures of locomotor activity. Depending on the behavioral measure, both tolerance and sensitization can occur in mice with repeated exposure to TCE. Both of these phenomena are characteristic of drugs of abuse.
Bhardwaj, Sanjeev K; Dodat, Fatéma; Lévesque, Daniel; Srivastava, Lalit K
2018-05-08
The mechanisms underlying psychostimulant drug-induced sensitization include long-term cellular and molecular adaptations in dopaminergic circuits. Nur77, a member of the Nur family of transcription factors, is expressed in brain regions receiving dopamine inputs and plays a role in activity-induced synaptic modification. Here we evaluated changes in Nur77 mRNA levels in the medial prefrontal cortex (mPFC), dorsal striatum (Str) and nucleus accumbens (NAc) of rats receiving a repeated, sensitizing regimen of amphetamine (AMPH). Results were compared to two groups of controls - animals receiving repeated injections of saline (Rp-SAL) or with no treatment (CON). Two weeks after the last injection, the effect of an acute challenge dose of AMPH on Nur77 expression was evaluated using in-situ hybridization. Repeated AMPH treatment (Rp-AMPH) increased the levels of Nur77 mRNA in the mPFC, NAc core and shell regions. However, the effects of an acute injection of AMPH in each of the three groups of animals was distinct. Whereas an acute AMPH led to a significant increase of Nur77 in all brain regions of the CON animals, it had no significant effect in Rp-SAL animals. Interestingly, in acute AMPH-injected Rp-AMPH animals, Nur77 mRNA levels in the mPFC, Str and NAc regions were significantly lower compared to CON and Rp-SAL animals treated with acute AMPH. There was a positive correlation between AMPH -induced locomotor activity and Nur77 mRNA expression in CON animals; however, this relationship was absent in Rp-SAL and Rp-AMPH animals. The data suggest that Nur77 is a part of neuroadaptive changes caused by either mild stress of repeated injections as well as AMPH-sensitization and may play a role in abnormal behaviors induced by the drug. Copyright © 2018. Published by Elsevier B.V.
40 CFR 1065.320 - Fuel-flow calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...
40 CFR 1065.320 - Fuel-flow calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...
40 CFR 1065.320 - Fuel-flow calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...
40 CFR 1065.320 - Fuel-flow calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...
40 CFR 1065.320 - Fuel-flow calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...
12 CFR 308.132 - Assessment of penalties.
Code of Federal Regulations, 2010 CFR
2010-01-01
... good faith of the bank or official, the gravity of the violation, the history of previous violations... bank's delinquency is lengthy or the bank has been delinquent repeatedly in making or publishing its...
Understanding the Referential Nature of Looking: Infants' Preference for Object-Directed Gaze
ERIC Educational Resources Information Center
Senju, Atsushi; Csibra, Gergely; Johnson, Mark H.
2008-01-01
In four experiments, we investigated whether 9-month-old infants are sensitive to the relationship between gaze direction and object location and whether this sensitivity depends on the presence of communicative cues like eye contact. Infants observed a face, which repeatedly shifted its eyes either toward, or away from, unpredictably appearing…
Evaluation of Screening for Retinopathy of Prematurity by ROPtool or a Lay Reader.
Abbey, Ashkan M; Besirli, Cagri G; Musch, David C; Andrews, Chris A; Capone, Antonio; Drenser, Kimberly A; Wallace, David K; Ostmo, Susan; Chiang, Michael; Lee, Paul P; Trese, Michael T
2016-02-01
To determine if (1) tortuosity assessment by a computer program (ROPtool, developed at the University of North Carolina, Chapel Hill, and Duke University, and licensed by FocusROP) that traces retinal blood vessels and (2) assessment by a lay reader are comparable with assessment by a panel of 3 retinopathy of prematurity (ROP) experts for remote clinical grading of vascular abnormalities such as plus disease. Validity and reliability analysis of diagnostic tools. Three hundred thirty-five fundus images of prematurely born infants. Three hundred thirty-five fundus images of prematurely born infants were obtained by neonatal intensive care unit nurses. A panel of 3 ROP experts graded 84 images showing vascular dilatation, tortuosity, or both and 251 images showing no evidence of vascular abnormalities. These images were sent electronically to an experienced lay reader who independently graded them for vascular abnormalities. The images also were analyzed using the ROPtool, which assigns a numerical value to the level of vascular abnormality and tortuosity present in each of 4 quadrants or sectors. The ROPtool measurements of vascular abnormalities were graded and compared with expert panel grades with a receiver operating characteristic (ROC) curve. Grades between human readers were cross-tabulated. The area under the ROC curve was calculated for the ROPtool, and sensitivity and specificity were computed for the lay reader. Measurements of vascular abnormalities by ROPtool and grading of vascular abnormalities by 3 ROP experts and 1 experienced lay reader. The ROC curve for ROPtool's tortuosity assessment had an area under the ROC curve of 0.917. Using a threshold value of 4.97 for the second most tortuous quadrant, ROPtool's sensitivity was 91% and its specificity was 82%. Lay reader sensitivity and specificity were 99% and 73%, respectively, and had high reliability (κ, 0.87) in repeated measurements. ROPtool had very good accuracy for detection of vascular abnormalities suggestive of plus disease when compared with expert physician graders. The lay reader's results showed excellent sensitivity and good specificity when compared with those of the expert graders. These options for remote reading of images to detect vascular abnormalities deserve consideration in the quest to use telemedicine with remote reading for efficient delivery of high-quality care and to detect infants requiring bedside examination. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
[Establishment of Automation System for Detection of Alcohol in Blood].
Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J
2017-02-01
To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine
Jahn, Ingeborg; Börnhorst, Claudia; Günther, Frauke; Brand, Tilman
2017-02-15
During the last decades, sex and gender biases have been identified in various areas of biomedical and public health research, leading to compromised validity of research findings. As a response, methodological requirements were developed but these are rarely translated into research practice. The aim of this study is to provide good practice examples of sex/gender sensitive health research. We conducted a systematic search of research articles published in JECH between 2006 and 2014. An instrument was constructed to evaluate sex/gender sensitivity in four stages of the research process (background, study design, statistical analysis, discussion). In total, 37 articles covering diverse topics were included. Thereof, 22 were evaluated as good practice example in at least one stage; two articles achieved highest ratings across all stages. Good examples of the background referred to available knowledge on sex/gender differences and sex/gender informed theoretical frameworks. Related to the study design, good examples calculated sample sizes to be able to detect sex/gender differences, selected sex/gender sensitive outcome/exposure indicators, or chose different cut-off values for male and female participants. Good examples of statistical analyses used interaction terms with sex/gender or different shapes of the estimated relationship for men and women. Examples of good discussions interpreted their findings related to social and biological explanatory models or questioned the statistical methods used to detect sex/gender differences. The identified good practice examples may inspire researchers to critically reflect on the relevance of sex/gender issues of their studies and help them to translate methodological recommendations of sex/gender sensitivity into research practice.
Korevaar, Erik W; Wauben, David J L; van der Hulst, Peter C; Langendijk, Johannes A; Van't Veld, Aart A
2011-09-01
IMRT QA is commonly performed in a phantom geometry but the clinical interpretation of the results in a 2D phantom plane is difficult. The main objective of our work is to move from film measurement based QA to 3D dose reconstruction in a patient CT scan. In principle, this could be achieved using a dose reconstruction method from 2D detector array measurements as available in the COMPASS system (IBA Dosimetry). The first step in the clinical introduction of this system instead of the currently used film QA procedures is to test the reliability of the dose reconstruction. In this paper we investigated the validation of the method in a homogeneous phantom with the film QA procedure as a reference. We tested whether COMPASS QA results correctly identified treatment plans that did or did not fulfil QA requirements in head and neck (H&N) IMRT. A total number of 24 treatments were selected from an existing database with more than 100 film based H&N IMRT QA results. The QA results were classified as either good, just acceptable or clinically rejected (mean gamma index <0.4, 0.4-0.5 or >0.5, respectively with 3%/3mm criteria). Film QA was repeated and compared to COMPASS QA with a MatriXX detector measurement performed on the same day. Good agreement was found between COMPASS reconstructed dose and film measured dose in a phantom (mean gamma 0.83±0.09, 1SD with 1%/1mm criteria, 0.33±0.04 with 3%/3mm criteria). COMPASS QA results correlated well with film QA, identifying the same patients with less good QA results. Repeated measurements with film and COMPASS showed changes in delivery after a modified MLC calibration, also visible in a standard MLC check in COMPASS. The time required for QA reduced by half by using COMPASS instead of film. Agreement of COMPASS QA results with film based QA supports its clinical introduction for a phantom geometry. A standard MLC calibration check is sensitive to <1mm changes that could be significant in H&N IMRT. These findings offer opportunities to further investigate the method based on a 2D detector array to 3D dose reconstruction in a patient anatomy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Toro, Brigitte; Nester, Christopher J; Farren, Pauline C
2007-03-01
To evaluate the inter- and intraobserver repeatability of the Salford Gait Tool (SF-GT), a new observation-based gait assessment tool for evaluating sagittal plane cerebral palsy (CP) gait. Masked comparative evaluation. University in the United Kingdom. A convenience sample of 23 pediatric physical therapists with varying degrees of clinical experience recruited from the Greater Manchester area. Participants viewed videotapes of the sagittal plane gait of 13 children and used the SF-GT to analyze their 13 different gait styles on 2 occasions. Eleven children had hemiplegic, diplegic, or quadriplegic CP and 2 were neurologically intact. Inter- and intraobserver repeatability of hip, knee, and ankle joint positions at 6 different phases of the gait cycle. The SF-GT demonstrated good interobserver (77%) and intraobserver (75%) repeatability. We have established that the SF-GT is a repeatable clinical assessment tool with which to guide the diagnosis, treatment planning, and evaluation of interventions by pediatric physical therapists of sagittal plane gait deviations in CP.
Illenberger, J M; Mactutus, C F; Booze, R M; Harrod, S B
2018-02-01
In those who use nicotine, the likelihood of dependence, negative health consequences, and failed treatment outcomes differ as a function of gender. Women may be more sensitive to learning processes driven by repeated nicotine exposure that influence conditioned approach and craving. Sex differences in nicotine's influence over overt behaviors (i.e. hypoactivity or behavioral sensitization) can be examined using passive drug administration models in male and female rats. Following repeated intravenous (IV) nicotine injections, behavioral sensitization is enhanced in female rats compared to males. Nonetheless, characteristics of the testing environment also mediate rodent behavior following drug administration. The current experiment used a within-subjects design to determine if nicotine-induced changes in horizontal activity, center entries, and rearing displayed by male and female rats is detected when behavior was recorded in round vs. square chambers. Behaviors were recorded from each group (males-round: n=19; males-square: n=18; females-square: n=19; and females-round: n=19) immediately following IV injection of saline, acute nicotine, and repeated nicotine (0.05mg/kg/injection). Prior to nicotine treatment, sex differences were apparent only in round chambers. Following nicotine administration, the order of magnitude for the chamber that provided enhanced detection of hypoactivity or sensitization was contingent upon both the dependent measure under examination and the animal's biological sex. As such, round and square testing chambers provide different, and sometimes contradictory, accounts of how male and female rats respond to nicotine treatment. It is possible that a central mechanism such as stress or cue sensitivity is impacted by both drug exposure and environment to drive the sex differences observed in the current experiment. Until these complex relations are better understood, experiments considering sex differences in drug responses should balance characteristics of the testing environment to provide a complete interpretation of drug-induced changes to behavior. Copyright © 2018 Elsevier Inc. All rights reserved.
Sun, Jinling; Tian, Lin; Cui, Ruisi; Li, Xinwang
2017-04-01
Acetylcholinesterase inhibitors are regarded as promising therapeutic agents to treat addiction. The current study aimed to examine the effects of huperzine A, a cholinesterase inhibitor, on behavioral sensitization induced by repeated morphine administration and relapse induced by contextual conditioning. The present study also assessed whether the state-dependency hypothesis may explain the results. Adult rats were divided into four groups (n=8) and intraperitoneally injected with 0.2, 0.3 or 0.4 mg/kg huperzine A or saline (1 ml/kg, control), for 5 days. The effect of repeated huperzine A administration alone on locomotor activity was assessed. For the experiments that analyzed the development of morphine-induced sensitization, 40 rats were divided into five groups (n=8): Saline+Saline, Saline+Morphine, 0.2, 0.3 and 0.4 mg/kg huperzine A+Morphine. Following a withdrawal period of 7 days, all animals were administered saline or morphine, as appropriate. To test the state-dependency hypothesis, the rats in the Saline+Morphine group were injected with saline and morphine, while the other three groups were administered different doses of huperzine A and morphine. To examine the effect of huperzine A on the expression of morphine-induced sensitization, the rats in huperzine A+Morphine groups were injected with appropriate concentrations of huperzine A, and morphine. The current results indicated that the administration of huperzine A alone did not affect locomotor activity, while higher doses of huperzine A inhibited the addictive behavior induced by morphine at the development phase. Additionally, huperzine A administration during the expression phase of morphine sensitization did not inhibit the relapse induced by administration of saline. Furthermore, 0.4 mg/kg huperzine A inhibited the expression of morphine-induced behavioral sensitization. Therefore, the results of the current study do not support the state-dependency hypothesis.
Sun, Jinling; Tian, Lin; Cui, Ruisi; Li, Xinwang
2017-01-01
Acetylcholinesterase inhibitors are regarded as promising therapeutic agents to treat addiction. The current study aimed to examine the effects of huperzine A, a cholinesterase inhibitor, on behavioral sensitization induced by repeated morphine administration and relapse induced by contextual conditioning. The present study also assessed whether the state-dependency hypothesis may explain the results. Adult rats were divided into four groups (n=8) and intraperitoneally injected with 0.2, 0.3 or 0.4 mg/kg huperzine A or saline (1 ml/kg, control), for 5 days. The effect of repeated huperzine A administration alone on locomotor activity was assessed. For the experiments that analyzed the development of morphine-induced sensitization, 40 rats were divided into five groups (n=8): Saline+Saline, Saline+Morphine, 0.2, 0.3 and 0.4 mg/kg huperzine A+Morphine. Following a withdrawal period of 7 days, all animals were administered saline or morphine, as appropriate. To test the state-dependency hypothesis, the rats in the Saline+Morphine group were injected with saline and morphine, while the other three groups were administered different doses of huperzine A and morphine. To examine the effect of huperzine A on the expression of morphine-induced sensitization, the rats in huperzine A+Morphine groups were injected with appropriate concentrations of huperzine A, and morphine. The current results indicated that the administration of huperzine A alone did not affect locomotor activity, while higher doses of huperzine A inhibited the addictive behavior induced by morphine at the development phase. Additionally, huperzine A administration during the expression phase of morphine sensitization did not inhibit the relapse induced by administration of saline. Furthermore, 0.4 mg/kg huperzine A inhibited the expression of morphine-induced behavioral sensitization. Therefore, the results of the current study do not support the state-dependency hypothesis. PMID:28413513
Breaks in the 45S rDNA Lead to Recombination-Mediated Loss of Repeats.
Warmerdam, Daniël O; van den Berg, Jeroen; Medema, René H
2016-03-22
rDNA repeats constitute the most heavily transcribed region in the human genome. Tumors frequently display elevated levels of recombination in rDNA, indicating that the repeats are a liability to the genomic integrity of a cell. However, little is known about how cells deal with DNA double-stranded breaks in rDNA. Using selective endonucleases, we show that human cells are highly sensitive to breaks in 45S but not the 5S rDNA repeats. We find that homologous recombination inhibits repair of breaks in 45S rDNA, and this results in repeat loss. We identify the structural maintenance of chromosomes protein 5 (SMC5) as contributing to recombination-mediated repair of rDNA breaks. Together, our data demonstrate that SMC5-mediated recombination can lead to error-prone repair of 45S rDNA repeats, resulting in their loss and thereby reducing cellular viability. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Nikounezhad, Nastaran; Nakhjavani, Maryam; Shirazi, Farshad H
2017-05-01
Cisplatin resistance development is a major obstacle in ovarian cancer treatment. One of the most important mechanisms underlying cisplatin resistance is drug detoxification by glutathione. In the present study, the importance of initial or repeated exposure to cisplatin in glutathione dependent resistance was investigated. To this purpose, some cisplatin sensitive and resistant variants of human ovarian cancer cell lines providing an appropriate range of cisplatin sensitivity were selected. Clonogenic survival assay was performed to evaluate cisplatin resistance and intracellular contents of reduced (GSH) and oxidized (GSSG) glutathione were analyzed using an HPLC method. Our results indicated that the intracellular GSH and GSSG concentrations were nearly equal in A2780 and A2780CP cells, while the A2780CP cells showed 14 times more resistance than the A2780 cells after initial exposure to cisplatin. A2780-R1 and A2780-R3 cells which have been repeatedly exposed to cisplatin also showed no significant difference in glutathione content, even though A2780-R3 was about two times more resistant than A2780-R1. Moreover, intracellular GSH/GSSG ratio decreased in the resistant cells, reflecting a shift towards a more oxidizing intracellular environment indicative of oxidative stress. As a conclusion, it seems that although the intracellular glutathione concentration increases after repeated exposure to cisplatin, there is no clear correlation between the intracellular GSH content in ovarian cancer cells and their resistance to cisplatin neither after initial nor after repeated exposure to this drug.
Floresco, Stan B; Whelan, Jennifer M
2009-08-01
Psychostimulant abuse has been linked to impairments in cost-benefit decision making. We assessed the effects of repeated amphetamine (AMPH) treatment in rodents on two distinct forms of decision making. Separate groups of rats were trained for 26 days on either a probabilistic (risk) or effort-discounting task, each consisting of four discrete blocks of ten choice trials. One lever always delivered a smaller reward (one or two pellets), whereas another lever delivered a four-pellet reward. For risk-discounting, the probability of receiving the larger reward decreased across trial blocks (100-12.5%), whereas on the effort task, four pellets could be obtained after a ratio of presses that increased across blocks (2-20). After training, rats received 15 saline or AMPH injections (escalating from 1 to 5 mg/kg) and were then retested during acute and long-term withdrawal. Repeated AMPH administration increased risky choice 2-3 weeks after drug exposure, whereas these treatments did not alter effort-based decision making in a separate group of animals. However, prior AMPH exposure sensitized the effects of acute AMPH on both forms of decision making, whereby lower doses were effective at inducing "risky" and "lazy" patterns of choice. Repeated AMPH exposure leads to relatively long-lasting increases in risky choice, as well as sensitization to the effects of acute AMPH on different forms of cost/benefit decision making. These findings suggest that maladaptive decision-making processes exhibited by psychostimulant abusers may be caused in part by repeated drug exposure.
Metsu, Sofie; Rainger, Jacqueline K; Debacker, Kim; Bernhard, Birgitta; Rooms, Liesbeth; Grafodatskaya, Daria; Weksberg, Rosanna; Fombonne, Eric; Taylor, Martin S; Scherer, Stephen W; Kooy, R Frank; FitzPatrick, David R
2014-11-01
We report de novo occurrence of the 7p11.2 folate-sensitive fragile site FRA7A in a male with an autistic spectrum disorder (ASD) due to a CGG-repeat expansion mutation (∼450 repeats) in a 5' intron of ZNF713. This expanded allele showed hypermethylation of the adjacent CpG island with reduced ZNF713 expression observed in a proband-derived lymphoblastoid cell line (LCL). His unaffected mother carried an unmethylated premutation (85 repeats). This CGG-repeat showed length polymorphism in control samples (five to 22 repeats). In a second unrelated family, three siblings with ASD and their unaffected father were found to carry FRA7A premutations, which were partially or mosaically methylated. In one of the affected siblings, mitotic instability of the premutation was observed. ZNF713 expression in LCLs in this family was increased in three of these four premutation carriers. A firm link cannot yet be established between ASD and the repeat expansion mutation but plausible pathogenic mechanisms are discussed. © 2014 WILEY PERIODICALS, INC.
Mottyll, Stephan; Skoda, Romuald
2016-07-01
As a contribution to a better understanding of cavitation erosion mechanisms, a compressible inviscid finite volume flow solver with barotropic homogeneous liquid-vapor mixture cavitation model is applied to ultrasonic horn set-ups with and without stationary specimen, that exhibit attached cavitation at the horn tip. Void collapses and shock waves, which are closely related to cavitation erosion, are resolved. The computational results are compared to hydrophone, shadowgraphy and erosion test data. At the horn tip, vapor volume and topology, subharmonic oscillation frequency as well as the amplitude of propagating pressure waves are in good agreement with experimental data. For the evaluation of flow aggressiveness and the assessment of erosion sensitive wall zones, statistical analyses of wall loads and of the multiplicity of distinct collapses in wall-adjacent flow regions are applied to the horn tip and the stationary specimen. An a posteriori projection of load collectives, i.e. cumulative collapse rate vs. collapse pressure, onto a reference grid eliminates the grid dependency effectively for attached cavitation at the horn tip, whereas a significant grid dependency remains at the stationary specimen. The load collectives show an exponential decrease towards higher collapse pressures. Erosion sensitive wall zones are well predicted for both, horn tip and stationary specimen, and load profiles are in good qualitative agreement with measured topography profiles of eroded duplex stainless steel samples after long-term runs. For the considered amplitude and gap width according to ASTM G32-10 standard, the analysis of load collectives reveals that the distinctive erosive ring shape at the horn tip can be attributed to frequent breakdown and re-development of a small portion of the tip-attached cavity. This partial breakdown of the attached cavity repeats at each driving cycle and is associated with relatively moderate collapse peak pressures, whereas the stationary specimen is rather unfrequently stressed at the end of each subharmonic oscillation cycle by the violent collapse of the complete cavity. Copyright © 2016 Elsevier B.V. All rights reserved.
RIFM fragrance ingredient safety assessment, benzyl butyrate, CAS Registry Number 103-37-7.
Api, A M; Belsito, D; Bhatia, S; Bruze, M; Calow, P; Dagli, M L; Dekant, W; Fryer, A D; Kromidas, L; La Cava, S; Lalko, J F; Lapczynski, A; Liebler, D C; Politano, V T; Ritacco, G; Salvito, D; Schultz, T W; Shen, J; Sipes, I G; Wall, B; Wilcox, D K
2016-11-01
The use of this material under current use conditions is supported by the existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data from the suitable read across analog benzyl acetate (CAS # 140-11-4) show that this material is not genotoxic nor does it have skin sensitization potential and also provided a MOE > 100 for the repeated dose, developmental and reproductive, and local respiratory toxicity endpoints. The phototoxicity/photoallergenicity endpoint was completed based on suitable UV spectra. The environmental endpoint was completed as described in the RIFM Framework. Copyright © 2016 Elsevier Ltd. All rights reserved.
RIFM fragrance ingredient safety assessment, isobornyl isovalerate, CAS registry number 7779-73-9.
Api, A M; Belsito, D; Bhatia, S; Bruze, M; Calow, P; Dagli, M L; Dekant, W; Fryer, A D; Kromidas, L; La Cava, S; Lapczynski, A; Liebler, D C; O'Brien, D; Parakhia, R; Penning, T M; Politano, V T; Ritacco, G; Salvito, D; Schultz, T W; Shen, J; Sipes, I G; Wall, B; Wilcox, D K
2017-12-01
This material was evaluated for genotoxicity, repeated dose toxicity, developmental toxicity, reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization potential, as well as, environmental safety. Data from the suitable read across analog isobornyl acetate (CAS # 125-12-2) show that this material is not genotoxic, provided a MOE > 100 for the repeated dose, developmental and reproductive endpoints, and does not have skin sensitization potential. The local respiratory toxicity endpoint was completed using the TTC (threshold of Toxicological Concern) for a Cramer Class II material (0.47 mg/day). The phototoxicity/photoallergenicity endpoint was completed based on suitable UV spectra. The environmental endpoint was completed as described in the RIFM Framework. Copyright © 2016 Elsevier Ltd. All rights reserved.
Measuring the arterial-induced skin vibration by geometrical moiré fringe
NASA Astrophysics Data System (ADS)
Chiu, Shih-Yung; Wang, Chun-Hsiung; Lee, Shu-Sheng; Wu, Wen-Jong; Hsu, Yu-Hsiang; Lee, Chih-Kung
2018-02-01
The demand for self-measured blood pressure self-monitoring device has much increased due to cardiovascular diseases have become leading causes of death for aging population. Currently, the primary non-invasive blood pressure monitoring method is cuff-based. It is well developed and accurate. However, the measuring process is not comfortable, and it cannot provide a continuous measurement. To overcome this problem, methods such as tonometry, volume clamp method, photoplethysmography, pulse wave velocity, and pulse transit time are reported. However, the limited accuracy hindered its application for diagnostics. To perform sequential blood pressure measurement with a high accuracy and long-term examination, we apply moiré interferometry to measure wrist skin vibration induced by radial artery. To achieve this goal, we developed a miniaturized device that can perform moiré interferometry around the wrist region. The 0.4-mm-pitched binary grating and tattoo sticker with 0.46 mm-pitched stripe pattern are used to perform geometric moiré. We demonstrated that the sensitivity and accuracy of this integrated system were sufficient to monitor arterialinduced skin vibration non-invasively. Our developed system was validated with ECG signals collected by a commercial system. According to our studies from measurement, the repeatability of wrist pulsation measurement was achieved with an accuracy of 99.1% in heart rate. A good repeatability of wrist pulse measurement was achieved. Simulations and experiments are both conducted in this paper and prove of geometrical moiré method a suitable technique for arterial-induced skin vibration monitoring.
Repeatability Evaluation of a Contrast Sensitivity System for Transfer to the Eye Clinic
NASA Astrophysics Data System (ADS)
Alcalde, N. G.; Castillo, L. R.; Filgueira, C. Paz; Colombo, E. M.
2016-04-01
The Contrast Sensitivity Function (CSF) is a valuable tool which can be used to characterize functional vision and also for the diagnosis and management of patients with different eye diseases. In spite of its usefulness, the CSF is currently hardly ever used in clinical practice. The aim of this study was to validate the use of the system called FVC-100 (Tecnovinc-UNT-CONICET, Argentina), which calculates the CSF, in order to transfer this important tool to ophthalmological clinics. The validation was carried out through the design of a repeatability test and the subsequent analysis of the results. Furthermore, we evaluated the impact of different factors influencing the repeatability of the measurements such as age and previous training. The tests were based on the discrimination of sinusoidal gratings for different spatial frequencies (1, 4 and 12 c/°) in both eyes of 12 people, aged between 20 and 70. The results show that the calculated values of SC of each subject have a high repeatability and are not dependent on age or training. These results allow us to conclude positively regarding the effectiveness of the FVC-100, and to validate its use in clinics for the calculation of the FSC as a standard measure of functional vision quality.
Rockall, Andrea G; Avril, Norbert; Lam, Raymond; Iannone, Robert; Mozley, P David; Parkinson, Christine; Bergstrom, Donald; Sala, Evis; Sarker, Shah-Jalal; McNeish, Iain A; Brenton, James D
2014-05-15
Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. Patients underwent two pretreatment baseline FDG-PET/CT (n = 21) and CECT (n = 20) at two clinical sites with different PET/CT instruments. Patients were included if they had at least one target lesion in the abdomen with a standardized uptake value (SUV) maximum (SUVmax) of ≥ 2.5 and a long axis diameter of ≥ 15 mm. Two independent reading methods were used to evaluate repeatability of tumor diameter and SUV uptake: on site and at an imaging clinical research organization (CRO). Tumor volume reads were only performed by CRO. In each reading set, target lesions were independently measured on sequential imaging. Median time between FDG-PET/CT was two days (range 1-7). For site reads, concordance correlation coefficients (CCC) for SUVmean, SUVmax, and tumor diameter were 0.95, 0.94, and 0.99, respectively. Repeatability coefficients were 16.3%, 17.3%, and 8.8% for SUVmean, SUVmax, and tumor diameter, respectively. Similar results were observed for CRO reads. Tumor volume CCC was 0.99 with a repeatability coefficient of 28.1%. There was excellent test-retest repeatability for FDG-PET/CT quantitative measurements across two sites and two independent reading methods. Cutoff values for determining change in SUVmean, SUVmax, and tumor volume establish limits to determine metabolic and/or volumetric response to treatment in platinum-sensitive relapsed ovarian cancer. ©2014 American Association for Cancer Research.
Cross-sectional evaluation of visuomotor tracking performance following subconcussive head impacts.
Brokaw, E B; Fine, M S; Kindschi, K E; Santago Ii, A C; Lum, P S; Higgins, M
2018-01-01
Repeated mild traumatic brain injury (mTBI) has been associated with increased risk of degenerative neurological disorders. While the effects of mTBI and repeated injury are known, studies have only recently started examining repeated subconcussive impacts, impacts that do not result in a clinically diagnosed mTBI. In these studies, repeated subconcussive impacts have been connected to cognitive performance and brain imaging changes. Recent research suggests that performance on a visuomotor tracking (VMT) task may help improve the identification of mTBI. The goal of this study was to investigate if VMT performance is sensitive to the cumulative effect of repeated subconcussive head impacts in collegiate men's lacrosse players. A cross-sectional, prospective study was completed with eleven collegiate men's lacrosse players. Participants wore helmet-mounted sensors and completed VMT and reaction time assessments. The relationship between cumulative impact metrics and VMT metrics were investigated. In this study, VMT performance correlated with repeated subconcussive head impacts; individuals approached clinically diagnosed mTBI-like performance as the cumulative rotational velocity they experienced increased. This suggests that repeated subconcussive impacts can result in measurable impairments and indicates that visuomotor tracking performance may be a useful tool for monitoring the effects of repeated subconcussive impacts.
Single sperm analysis of the trinucleotide repeat in the Huntington`s disease gene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leeflang, E.P.; Zhang, L.; Hubert, R.
1994-09-01
Huntington`s disease (HD) is one of several genetic diseases caused by trinucleotide repeat expansion. The CAG repeat is very unstable, with size changes occurring in more than 80% of transmissions. The degree of instability of this repeat in the male germline can be determined by analysis of individual sperm cells. An easy and sensitive PCR assay has been developed to amplify this trinucleotide repeat region from single sperm using two rounds of PCR. As many as 90% of the single sperm show amplification for the HD repeat. The PCR product can be easily detected on an ethidium bromide-stained agarose gel.more » Single sperm samples from an HD patient with 18 and 49 repeats were studied. We observed size variations for the expanded alleles while the size of the normal allele in sperm is very consistent. We did not detect any significant bias in the amplification of normal alleles over the larger HD alleles. Our preliminary study supports the observation made by PCR of total sperm that instability of the HD trinucleotide repeat occurs in the germline. HD preimplantation diagnosis on single embryo blastomeres may also possible.« less
Potentiometric Zinc Ion Sensor Based on Honeycomb-Like NiO Nanostructures
Abbasi, Mazhar Ali; Ibupoto, Zafar Hussain; Hussain, Mushtaque; Khan, Yaqoob; Khan, Azam; Nur, Omer; Willander, Magnus
2012-01-01
In this study honeycomb-like NiO nanostructures were grown on nickel foam by a simple hydrothermal growth method. The NiO nanostructures were characterized by field emission electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) techniques. The characterized NiO nanostructures were uniform, dense and polycrystalline in the crystal phase. In addition to this, the NiO nanostructures were used in the development of a zinc ion sensor electrode by functionalization with the highly selective zinc ion ionophore 12-crown-4. The developed zinc ion sensor electrode has shown a good linear potentiometric response for a wide range of zinc ion concentrations, ranging from 0.001 mM to 100 mM, with sensitivity of 36 mV/decade. The detection limit of the present zinc ion sensor was found to be 0.0005 mM and it also displays a fast response time of less than 10 s. The proposed zinc ion sensor electrode has also shown good reproducibility, repeatability, storage stability and selectivity. The zinc ion sensor based on the functionalized NiO nanostructures was also used as indicator electrode in potentiometric titrations and it has demonstrated an acceptable stoichiometric relationship for the determination of zinc ion in unknown samples. The NiO nanostructures-based zinc ion sensor has potential for analysing zinc ion in various industrial, clinical and other real samples. PMID:23202217
Wang, Li; Ye, Yinjian; Zhu, Haozhi; Song, Yonghai; He, Shuijian; Xu, Fugang; Hou, Haoqing
2012-11-16
Glucose detection is very important in biological analysis, clinical diagnosis and the food industry, and especially for the routine monitoring of diabetes. This work presents an electrochemical approach to the detection of glucose based on Prussian blue (PB) nanostructures/carboxylic group-functionalized carbon nanofiber (FCNF) nanocomposites. The hybrid nanocomposites were constructed by growing PB onto the FCNFs. The obtained PB-FCNF nanocomposites were characterized by scanning electron microscopy, x-ray diffraction and x-ray photoelectron spectroscopy. The mechanism of formation of PB-FCNF nanocomposites was investigated and is discussed in detail. The PB-FCNF modified glassy carbon electrode (PB-FCNF/GCE) shows good electrocatalysis toward the reduction of H(2)O(2), a product from the reduction of O(2) followed by glucose oxidase (GOD) catalysis of the oxidation of glucose to gluconic acid. Further immobilizing GOD on the PB-FCNF/GCE, an amperometric glucose biosensor was achieved by monitoring the generated H(2)O(2) under a relatively negative potential. The resulting glucose biosensor exhibited a rapid response of 5 s, a low detection limit of 0.5 μM, a wide linear range of 0.02-12 mM, a high sensitivity of 35.94 μA cm(-2) mM(-1), as well as good stability, repeatability and selectivity. The sensor might be promising for practical application.
Assessment of partial coalescence in whippable oil-in-water food emulsions.
Petrut, Raul Flaviu; Danthine, Sabine; Blecker, Christophe
2016-03-01
Partial coalescence influences to a great extent the properties of final food products such as ice cream and whipped toppings. In return, the partial coalescence occurrence and development are conditioned, in such systems, by the emulsion's intrinsic properties (e.g. solid fat content, fat crystal shape and size), formulation (e.g. protein content, surfactants presence) and extrinsic factors (e.g. cooling rate, shearing). A set of methods is available for partial coalescence investigation and quantification. These methods are critically reviewed in this paper, balancing the weaknesses of the methods in terms of structure alteration (for turbidity, dye dilution, etc.) and assumptions made for mathematical models (for particle size determination) with their advantages (good repeatability, high sensitivity, etc.). With the methods proposed in literature, the partial coalescence investigations can be conducted quantitatively and/or qualitatively. Good correlation were observed between some of the quantitative methods such as dye dilution, calorimetry, fat particle size; while a poor correlation was found in the case of solvent extraction method with other quantitative methods. The most suitable way for partial coalescence quantification was implied to be the fat particle size method, which would give results with a high degree of confidence if used in combination with a microscopic technique for the confirmation of partial coalescence as the main destabilization mechanism. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, Jingyi; Zhu, Rong; Huang, Jia; Zhang, Man; Liu, Hongyu; Sun, Min; Wang, Li; Song, Yonghai
2015-08-21
A novel glucose biosensor was developed by immobilizing glucose oxidase (GOD) on a three-dimensional (3D) porous kenaf stem-derived carbon (3D-KSC) which was firstly proposed as a novel supporting material to load biomolecules for electrochemical biosensing. Here, an integrated 3D-KSC electrode was prepared by using a whole piece of 3D-KSC to load the GOD molecules for glucose biosensing. The morphologies of integrated 3D-KSC and 3D-KSC/GOD electrodes were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The SEM results revealed a 3D honeycomb macroporous structure of the integrated 3D-KSC electrode. The TEM results showed some microporosities and defects in the 3D-KSC electrode. The electrochemical behaviors and electrocatalytic performance of the integrated 3D-KSC/GOD electrode were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The effects of pH and scan rates on the electrochemical response of the biosensor have been studied in detail. The glucose biosensor showed a wide linear range from 0.1 mM to 14.0 mM with a high sensitivity of 1.73 μA mM(-1) and a low detection limit of 50.75 μM. Furthermore, the glucose biosensor exhibited high selectivity, good repeatability and reproducibility, and good stability.
Novel approaches to analysis of 3-chloropropane-1,2-diol esters in vegetable oils.
Moravcova, Eliska; Vaclavik, Lukas; Lacina, Ondrej; Hrbek, Vojtech; Riddellova, Katerina; Hajslova, Jana
2012-03-01
A sensitive and accurate method utilizing ultrahigh performance liquid chromatography (U-HPLC) coupled to high resolution mass spectrometry based on orbitrap technology (orbitrapMS) for the analysis of nine 3-chloropropane-1,2-diol (3-MCPD) diesters in vegetable oils was developed. To remove the interfering triacylglycerols that induce strong matrix effects, a clean-up step on silica gel column was used. The quantitative analysis was performed with the use of deuterium-labeled internal standards. The lowest calibration levels estimated for the respective analytes ranged from 2 to 5 μg kg(-1). Good recovery values (89-120%) and repeatability (RSD 5-9%) was obtained at spiking levels of 2 and 10 mg kg(-1). As an alternative, a novel ambient desorption ionization technique, direct analysis in real time (DART), hyphenated with orbitrapMS, was employed for no separation, high-throughput, semi-quantitative screening of 3-MCPD diesters in samples obtained by chromatographic fractionation. Additionally, the levels of 3-MCPD diesters measured in reallife vegetable oil samples (palm oil, sunflower oil, rapeseed oil) using both methods are reported. Relatively good agreement of the data generated by U-HPLC-orbitrapMS and DART-orbitrapMS were observed. With regard to a low ionization yield achieved for 3-MCPD monoesters, the methods presented in this paper were not yet applicable for the analysis of these contaminants at the naturally occurring levels.
The relationship between ischaemia-modified albumin and good coronary collateral circulation.
Gök, Murat; Kundi, Harun; Kızıltunç, Emrullah; Topcuoglu, Canan; Ornek, Ender
2018-01-01
It is important to determine the grade of the coronary collateral circulation (CCC) in patients with stable coronary artery disease. In this study, we aimed to investigate the relationship between the ischaemia-modified albumin (IMA) level and good CCC. A total of 95 patients with coronary angiography and at least one epicardial coronary artery obstruction were included in the study. The Rentrop classification was used with CCC grading, where 0 and 1 were defined as poor collateral, and 2 and 3 were defined as good collateral. The IMA level of the patients was measured using an enzyme-linked immunosorbent assay (ELISA). The receiver-operating characteristic curve was used to show the sensitivity and specificity of IMA levels and the optimal cut-off value for predicting good CCC. The multiple logistic regression analysis revealed that the IMA level in the good CCC group was higher (p < 0.045). Conversely, the high-sensitivity C-reactive protein level was lower in the good CCC group (p < 0.023). We found an IMA cut-off value (4.7 ng/mL) that indicated good CCC level, and this shows good CCC with 70.2% sensitivity and 60.3% specificity. The IMA level could serve as a simple and useful predictor of well-developed CCC.
Agreement and repeatability of objective systems for assessment of the tear film.
Fernández, Joaquín; Rodríguez-Vallejo, Manuel; Martínez, Javier; Tauste, Ana; García-Montesinos, Javier; Piñero, David P
2018-04-18
To assess the agreement and repeatability of two objective systems for measuring the tear film stability. Retrospective analysis of the tear film stability of 99 healthy right eyes measured with a videokeratoscope (VK) and the Optical Quality Analysis System (OQAS, Visiometrics). Two consecutive measures were taken with both systems, with an interval of 10 min between them. Variables included in the study were first and mean non-invasive break-up times (NIBUT and MNIBUT) measured with VK, and mean and standard deviation of the optical scattering index (OSIm and OSIsd) measured with OQAS. The agreement and repeatability of grading scales provided by both devices were also evaluated using the Cohen's k with quadratic weights. The Ocular Surface Disease index (OSDI) questionnaire was also passed out to all subjects. Correlations and associations between subjective and objective metrics were analyzed. Significant differences were found between consecutive measurements of NIBUT (p = 0.04) and MNIBUT (p = 0.01), but not for OSIm (p = 0.11) and OSIsd (p = 0.50). Grading scales resulted in fair (k = 0.20) or poor agreement (k = 0.04) between systems depending if the first or second trial was considered. The repeatability of the grading scale was good for OQAS (k = 0.59) and fair for VK (k = 0.37). No significant correlations or associations were found between OSDI and any of the metrics obtained with both devices (p ≥ 0.36). The two devices evaluated cannot be used interchangeably for the assessment of tear film stability. Good intrasession repeatability was obtained for tear film grading of the OQAS whereas it was fair for VK.
The Half RR Rule: A Poor Rule of Thumb and Not a Risk Assessment Tool for QT Interval Prolongation.
Berling, Ingrid; Isbister, Geoffrey K
2015-10-01
Measuring the QT interval on an electrocardiogram (ECG) is integral to risk assessment of Torsade de Pointes (TdP). This study aimed to investigate the accuracy of the 1/2 RR rule as a risk assessment tool for drug-induced TdP, comparing it to the QT nomogram, Bazett's corrected QT (QTcB), and Fridericia's corrected QT (QTcF). The authors calculated sensitivity and specificity of the 1/2 RR rule using a published data set of 129 cases of drug-induced TdP and 316 controls (noncardiotoxic overdoses), compared to the QT nomogram, QTcB > 500 msec and QTcF > 500 msec. To further determine the value of the 1/2 RR rule, its observed positive, and negative agreement were calculated when compared to the QT nomogram for determining an abnormal QT in eight samples of different drugs in overdose. The sensitivity and specificity of the 1/2 RR rule were 88% (95% confidence interval [CI] = 80% to 93%) and 53% (95% CI = 47% to 58%), respectively, compared to the QT nomogram (sensitivity = 97%, 95% CI = 92% to 99%; specificity = 99%, 95% CI = 97% to 100%). It was also less sensitive than QTcB > 500 msec and had a lower specificity than QTcB > 500 msec and QTcF > 500 msec. In drug overdose patients, the 1/2 RR rule had poor observed agreement averaging 41%, which was mainly due to poor positive agreement, except for amisulpride where there was good agreement. The 1/2 RR rule was not as sensitive as the QT nomogram or QTcB > 500 msec for drug-induced TdP. It had poor positive agreement in almost all overdose patients, resulting in over half of patients receiving unnecessary cardiac monitoring and repeat ECGs. © 2015 by the Society for Academic Emergency Medicine.
Glynn, Dervila; Skillings, Elizabeth A; Morton, A Jennifer
2016-05-30
Progressive cognitive impairments are a major, debilitating symptom of neurodegenerative disorders such as Alzheimer's disease (AD) and Huntington's disease (HD). Developing treatments to slow or prevent cognitive decline is a key challenge for these fields. Unfortunately, preclinical therapeutic testing has not kept pace with molecular advances, and the methods for systematic cognitive testing in mice remain largely unchanged. Although higher throughput semi-automated systems exist, the lack of a 'positive control' (i.e. a drug or treatment that works) makes it challenging to test their sensitivity and predict usefulness for preclinical drug testing. We used an allelic series of transgenic HD mice to test the sensitivity and flexibility of two cognitive testing systems; a semi-automated touchscreen system and a traditional water-based task, the 2-choice swim tank. We found significant differences in performance of HD mice with different CAG repeats, with timing and severity of deficits dependent on CAG repeat length. We also found deficits in long-term memory retention that have not been reported previously. Both systems were useful for detecting deficits, and were sensitive enough to detect small changes (10-20%) in cognitive performance. While the touchscreen system is more sensitive and can identify deficits up to 10 weeks earlier than the 2-choice swim tank, both tests detected similar patterns of deficit progression in HD mice, regardless of CAG repeat length. Thus, although it has its limitations, the 2-choice swim tank remains a simple, cheap and accessible system for assessing cognitive function. Copyright © 2015 Elsevier B.V. All rights reserved.
LeBlanc, Kimberly H; Maidment, Nigel T; Ostlund, Sean B
2013-01-01
There is growing evidence that mere exposure to drugs can induce long-term alterations in the neural systems that mediate reward processing, motivation, and behavioral control, potentially causing the pathological pursuit of drugs that characterizes the addicted state. The incentive sensitization theory proposes that drug exposure potentiates the influence of reward-paired cues on behavior. It has also been suggested that drug exposure biases action selection towards the automatic execution of habits and away from more deliberate goal-directed control. The current study investigated whether rats given repeated exposure to peripherally administered cocaine would show alterations in incentive motivation (assayed using the Pavlovian-to-instrumental transfer (PIT) paradigm) or habit formation (assayed using sensitivity to reward devaluation). After instrumental and Pavlovian training for food pellet rewards, rats were given 6 daily injections of cocaine (15 mg/kg, IP) or saline, followed by a 10-d period of rest. Consistent with the incentive sensitization theory, cocaine-treated rats showed stronger cue-evoked lever pressing than saline-treated rats during the PIT test. The same rats were then trained on a new instrumental action with a new food pellet reward before undergoing a reward devaluation testing. Although saline-treated rats exhibited sensitivity to reward devaluation, indicative of goal-directed performance, cocaine-treated rats were insensitive to this treatment, suggesting a reliance on habitual processes. These findings, when taken together, indicate that repeated exposure to cocaine can cause broad alterations in behavioral control, spanning both motivational and action selection processes, and could therefore help explain aberrations of decision-making that underlie drug addiction.
LeBlanc, Kimberly H.; Maidment, Nigel T.; Ostlund, Sean B.
2013-01-01
There is growing evidence that mere exposure to drugs can induce long-term alterations in the neural systems that mediate reward processing, motivation, and behavioral control, potentially causing the pathological pursuit of drugs that characterizes the addicted state. The incentive sensitization theory proposes that drug exposure potentiates the influence of reward-paired cues on behavior. It has also been suggested that drug exposure biases action selection towards the automatic execution of habits and away from more deliberate goal-directed control. The current study investigated whether rats given repeated exposure to peripherally administered cocaine would show alterations in incentive motivation (assayed using the Pavlovian-to-instrumental transfer (PIT) paradigm) or habit formation (assayed using sensitivity to reward devaluation). After instrumental and Pavlovian training for food pellet rewards, rats were given 6 daily injections of cocaine (15 mg/kg, IP) or saline, followed by a 10-d period of rest. Consistent with the incentive sensitization theory, cocaine-treated rats showed stronger cue-evoked lever pressing than saline-treated rats during the PIT test. The same rats were then trained on a new instrumental action with a new food pellet reward before undergoing a reward devaluation testing. Although saline-treated rats exhibited sensitivity to reward devaluation, indicative of goal-directed performance, cocaine-treated rats were insensitive to this treatment, suggesting a reliance on habitual processes. These findings, when taken together, indicate that repeated exposure to cocaine can cause broad alterations in behavioral control, spanning both motivational and action selection processes, and could therefore help explain aberrations of decision-making that underlie drug addiction. PMID:23646106
Ma, Guoming; Mao, Naiqiang; Li, Yabo; Jiang, Jun; Zhou, Hongyang; Li, Chengrong
2016-01-01
Heavy ice coating of high–voltage overhead transmission lines may lead to conductor breakage and tower collapse causing the unexpected interrupt of power supply. The optical load cell applied in ice monitoring systems is immune to electromagnetic interference and has no need of a power supply on site. Therefore, it has become a hot research topic in China and other countries. In this paper, to solve the problem of eccentric load in measurement, we adopt the shearing structure with additional grooves to improve the strain distribution and acquire good repeatability. Then, the fiber Bragg grating (FBG) with a permanent weldable package are mounted onto the front/rear groove of the elastic element by spot welding, the direction deviation of FBGs is 90° from each other to achieve temperature compensation without an extra FBG. After that, protection parts are designed to guarantee high sensitivity for a light load condition and industrial safety under a heavy load up to 65 kN. The results of tension experiments indicate that the sensitivity and resolution of the load cell is 0.1285 pm/N and 7.782 N in the conventional measuring range (0–10 kN). Heavy load tension experiments prove that the protection structure works and the sensitivity and resolution are not changed after several high load (65 kN) cycles. In addition, the experiment shows that the resolution of the sensor is 87.79 N in the large load range, allowing the parameter to be used in heavy icing monitoring. PMID:27338403
Dong, Ying; Yan, Kuan; Ma, Yanhua; Wang, Shan; He, Genye; Deng, Jing; Yang, Zhiyong
2015-10-01
A novel, reliable and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed with dynamic multiple reaction monitoring (dMRM) mode for the simultaneous screening of 71 stimulants and 7 metabolites in human urine using unsophisticated MS instruments (Agilent triple-quadruple 6410 B mass spectrometer). With a known retention time of an analyte, dMRM algorithm monitors each MRM transition only around its expected retention time. Therefore, dMRM enables the maximization of dwell times and provides much higher sensitivity and reproducibility than the conventional multiple reaction monitoring mode (cMRM). After precipitation of protein, the urine sample was injected into LC-MS-MS system directly without sample pre-concentration. For comparison, cMRM and dMRM acquisitions were performed under the same chromatographic conditions. The result showed that the signal response and quality of the chromatograms for each stimulant improved significantly with dMRM over cMRM. The method has been fully validated giving limits of detection (0.1-25 ng/mL) satisfactory for its application to anti-doping analysis. The repeatability of the concentrations and the retention times are good both for intra- and for inter-day experiments (%CV of concentrations always <20 and %CV of retention times <0.5). The method also afforded satisfactory results in terms of accuracy, matrix effect and specificity. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Observations on saliva osmolality during progressive dehydration and partial rehydration.
Taylor, Nigel A S; van den Heuvel, Anne M J; Kerry, Pete; McGhee, Sheena; Peoples, Gregory E; Brown, Marc A; Patterson, Mark J
2012-09-01
A need exists to identify dehydrated individuals under stressful settings beyond the laboratory. A predictive index based on changes in saliva osmolality has been proposed, and its efficacy and sensitivity was appraised across mass (water) losses from 1 to 7%. Twelve euhydrated males [serum osmolality: 286.1 mOsm kg(-1) H(2)O (SD 4.3)] completed three exercise- and heat-induced dehydration trials (35.6°C, 56% relative humidity): 7% dehydration (6.15 h), 3% dehydration (with 60% fluid replacement: 2.37 h), repeat 7% dehydration (5.27 h). Expectorated saliva osmolality, measured at baseline and at each 1% mass change, was used to predict instantaneous hydration state relative to mass losses of 3 and 6%. Saliva osmolality increased linearly with dehydration, although its basal osmolality and its rate of change varied among and within subjects across trials. Receiver operating characteristic curves indicated a good predictive power for saliva osmolality when used with two, single-threshold cutoffs to differentiate between hydrated and dehydrated individuals (area under curve: 3% cutoff = 0.868, 6% cutoff = 0.831). However, when analysed using a double-threshold detection technique (3 and 6%), as might be used in a field-based monitor, <50% of the osmolality data could correctly identify individuals who exceeded 3% dehydration. Indeed, within the 3-6% dehydration range, its sensitivity was 64%, while beyond 6% dehydration, this fell to 42%. Therefore, while expectorated saliva osmolality tracked mass losses within individuals, its large intra- and inter-individual variability limited its predictive power and sensitivity, rendering its utility questionable within a universal dehydration monitor.
Time-dependent pH sensing phenomena using CdSe/ZnS quantum dots in EIS structure
2014-01-01
Time-dependent pH sensing phenomena of the core-shell CdSe/ZnS quantum dot (QD) sensors in EIS (electrolyte insulator semiconductor) structure have been investigated for the first time. The quantum dots are immobilized by chaperonin GroEL protein, which are observed by both atomic force microscope and scanning electron microscope. The diameter of one QD is approximately 6.5 nm. The QDs are not oxidized over a long time and core-shell CdSe/ZnS are confirmed by X-ray photon spectroscopy. The sensors are studied for sensing of hydrogen ions concentration in different buffer solutions at broad pH range of 2 to 12. The QD sensors show improved sensitivity (38 to 55 mV/pH) as compared to bare SiO2 sensor (36 to 23 mV/pH) with time period of 0 to 24 months, owing to the reduction of defects in the QDs. Therefore, the differential sensitivity of the QD sensors with respect to the bare SiO2 sensors is improved from 2 to 32 mV/pH for the time period of 0 to 24 months. After 24 months, the sensitivity of the QD sensors is close to ideal Nernstian response with good linearity of 99.96%. Stability and repeatability of the QD sensors show low drift (10 mV for 10 cycles) as well as small hysteresis characteristics (<10 mV). This QD sensor is very useful for future human disease diagnostics. PMID:24725352
Matias, Ana Rita; Ferreira, Marta; Costa, Paulo; Neto, Patrícia
2015-08-01
The actual skin colorimeters analyse reflect values from a limited number of broad spectral bands and consequently present limited reproducibility and specificity when measuring skin colour. Here, Antera 3D(®) , a new device which uses reflectance mapping of seven different light wavelengths spanning the entire visible spectrum, has been compared with Mexameter(®) MX-18, an established narrow-band reflectance spectrophotometer and with Colorimeter(®) CL-400, an established tristimulus colorimetric instrument. Thirty volunteers were exposed to a controlled ultra-violet B light. Measurements with Antera 3D(®) , Mexameter(®) MX-18 and Colorimeter(®) CL-400 were done before treatment and after 2, 7 and 14 days. Antera 3D(®) showed to have a better sensitivity and specificity than Mexameter(®) MX-18 regarding the melanin parameter. A similar sensitivity between Antera 3D(®) and Mexameter(®) MX-18 was found for erythema determination and also for the Commission Internationale de l'Eclairage L*, a* and b* parameters between Antera 3D(®) and Colorimeter(®) CL-400. Good correlations were observed for all the parameters analysed. Repeatability of Mexameter(®) MX-18 and Colorimeter(®) CL-400 values were lower than that of Antera 3D(®) for all the parameters analysed. Antera 3D(®) , such as Mexameter(®) MX-18 and Colorimeter(®) CL-400, are robust, sensitive and precise equipment for the skin colour analysis. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Maric, N P; Stojanovic, Z; Andric, S; Soldatovic, I; Dolic, M; Spiric, Z
2016-03-01
Current literature provides insufficient information on the degree of cognitive impairment during and after electroconvulsive therapy (ECT), mostly due to the fact that applied tests lacked sensitivity and flexibility. Our goal was to evaluate cognitive functioning in adult depressed patients treated with bi-temporal ECT, using tests sensitive for detection of possible acute and medium-term memory changes. Thirty adult patients with major depressive disorder, treated with a course of bi-temporal ECT, underwent clinical and cognitive measurements three times: at baseline, immediately after a course of ECT, and 1 month later. For cognition assessment, we used learning and visual, spatial and figural memory tests from the Cambridge Neuropsychological Test Automated Battery (CANTAB). Bi-temporal ECT has proven to be an effective treatment. The linear mixed model, used to analyze changes in depression severity and patients' cognitive performances over time and to assess dynamic correlations between aforementioned features, did not show any significant memory impairment as a potential acute or medium-term ECT effect. However, it yielded significant improvement on visual memory and learning at the follow-up, which positively correlated with the improvement of depression. Good progress is being made in the search for ECT-related acute and medium-term cognitive side-effects by using the tests sensitive to detect memory dysfunction with parallel forms of the tasks (to counter practice effects on repeat testing). Our results on learning and memory in relation to ECT during treatment of depression did not bring forth any prolonged and significant bi-temporal ECT-related memory deficit.
Yusko, Brittany; Hawk, Kiel; Schiml, Patricia A.; Deak, Terrence; Hennessy, Michael B.
2011-01-01
Infant guinea pigs exhibit a 2-stage response to maternal separation: an initial active stage, characterized by vocalizing, and a second passive stage marked by depressive-like behavior (hunched posture, prolonged eye-closure, extensive piloerection) that appears to be mediated by proinflammatory activity. Recently we found that pups showed an enhanced (i.e., sensitized) depressive-like behavioral response during repeated separation. Further, core body temperature was higher during the beginning of a second separation compared to the first, suggesting a more-rapid stress-induced febrile response to separation the second day, though the possibility that temperature was already elevated prior to the second separation could not be ruled out. Therefore, the present study examined temperature prior to, and during, 2 daily separations. We also examined the temperature response to a third separation conducted 3 days after the second, and assessed the effect of repeated separation on plasma cortisol levels. Core temperature did not differ just prior to the separations, but showed a more-rapid increase and then decline during both a second and third separation than during a first. Temperature responses were not associated with changes in motor activity. Depressive-like behavior was greater during the second and third separations. Pups separated a first time showed a larger plasma cortisol response at the conclusion of separation than did animals of the same age separated a third time. In all, the results indicate that the sensitization of depressive-like behavior during repeated separations over several days is accompanied by a more-rapid febrile response that may be related to a reduction of glucocorticoid suppression. PMID:22079581
Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton
2016-01-01
Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003
Lane, E L; Cheetham, S C; Jenner, P
2005-01-01
BTS 74 398 (1-[1-(3,4-dichlorophenyl)cyclobutyl]-2-(3-diaminethylaminopropylthio)ethanone monocitrate) is a monoamine reuptake inhibitor that reverses motor deficits in MPTP-treated (1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) common marmosets without provoking established dyskinesia. However, it is not known whether BTS 74 398 primes the basal ganglia for dyskinesia induction. In this study, the ability of BTS 74 398 to sensitize 6-hydroxydopamine (6-OHDA)-lesioned rats for the production of abnormal motor behaviours and the induction of striatal DeltaFosB were determined in comparison with l-3,4-dihydroxyphenylalanine methyl ester (L-dopa). Acute administration of BTS 74 398 induced a dose-dependent ipsilateral circling response in unilaterally 6-OHDA-lesioned rats whereas L-dopa produced dose-dependent contraversive rotation. The ipsilateral circling response to BTS 74 398 did not alter during 21 days of administration. In contrast, L-dopa treatment for 21 days caused a marked increase in rotational response. Repeated administration of both L-dopa and BTS 74 398 increased general motor activity and stereotypic behaviour. In L-dopa-treated rats, orolingual, locomotive, forelimb and axial abnormal movements developed whereas BTS 74 398 produced only locomotion with a side bias but no other abnormal movements. Sensitization of circling responses and the development of abnormal movements in 6-OHDA-lesioned rats have been associated with the potential of dopaminergic drugs to induce dyskinesia. Furthermore, striatal DeltaFosB immunoreactivity, shown to correlate with dyskinesia induction, was increased by L-dopa but was unaffected by repeated BTS 74 398 administration. The lack of such changes following repeated BTS 74 398 treatment suggests that it may be an effective antiparkinsonian therapy that is unlikely to produce involuntary movements.
Enhanced appetitive conditioning following repeated pretreatment with d-amphetamine.
Harmer, C J; Phillips, G D
1998-07-01
The behavioural response to psychomotor stimulants is augmented with repeated exposure to these drugs. Enhanced stimulated dopamine overflow within the nucleus accumbens and amygdala has been found to accompany this behavioural sensitization. In the present experiment, rats received 2 mg/kg d-amphetamine or 1 ml/kg physiological saline once per day for 5 days. Five days later, a behavioural assay confirmed that prior repeated d-amphetamine treatment markedly enhanced the locomotor activating effects of a d-amphetamine (0.5 mg/kg, i.p.) challenge. Training on a Pavlovian conditioning task began six days subsequently. In Stage 1, a stimulus (light or tone, S-) was presented negatively correlated with a sucrose reward. In Stage 2, presentation of the alternative counterbalanced stimulus (light or tone, S+) was paired with the availability of a 10% sucrose solution. There were no differences between the two groups in their response to the the S- stimulus. However, sensitized animals showed a selective enhancement in the acquisition of conditioned responding to S+, relative to vehicle-injected controls. No differences in behaviour were recorded during the prestimulus periods, nor during presentations of sucrose. Levels of activity within the operant chamber extraneous to alcove approach were also similar in both groups of animals. The conditioned instrumental efficacy of S+, relative to S- was assessed in Stage 3, in which stimulus availability was made contingent on a novel lever-pressing response. Both groups showed a similar preference for the S+ over the S- stimulus. Hence, rats sensitized by prior repeated d-amphetamine showed enhanced appetitive Pavlovian conditioning, without subsequent effect on conditioned reward efficacy. These data are discussed in light of possible changes in mesoamygdaloid dopamine functioning.
Neonatal mastitis: a clinico-microbiological study.
Masoodi, Talat; Mufti, Gowhar Nazir; Bhat, Javeed Iqbal; Lone, Rubina; Arshi, Syed; Ahmad, Syed Khurshid
2014-01-01
Neonatal breast hypertrophy is a common phenomenon in term infants, superadded infection can lead to mastitis and that can progress to breast abscess with short and long term detrimental effects. Our effort is to study the prevalence, risk factors, the current microbial profile and sensitivity pattern in these infections in order to suggest an optimal treatment plan for these patients. Case series. Hospital based study conducted in Kashmir on the native population. 2011 to 2013. 32 neonates with features of mastitis or abscess were included in the study. Demographic and clinical data, laboratory work-up were recorded for all these patients in a patient form. Gram stain of the purulent nipple discharge or pus obtained on drainage was done and the specimens were culture plated. Antibiotic sensitivity was determined by disk diffusion and categorized by current Clinical and Laboratory Standards Institute (CLSI) guidelines. Most babies were full term, the age range was 6-48 days. Peak incidence for mastitis was in the 2nd week and for abscess in the 4th week. The ratio of male: female was 1:2 in the entire group, there was greater preponderance of female involvement with increasing age. Massage for expression of secretions a common practice in the study population had been done in 15 patients, especially in male babies. The babies were generally well and associated skin pustulosis was common. Laboratory workup showed polymorphonuclear leucocytosis and CRP positivity. Gram staining showed gram positive cocci in 13 patients and gram negative rods in 1 patient. Culture revealed Staphylococcus aureus in 18, E.col in 2, klebsiella in 1 patient and was sterile in 2 patients. Most strains of Staphylococcus aureus were resistant to macrolides and penicillins. Fifteen were methicillin sensitive and 3 were resistant but were sensitive to amikacin, ofloxacin and vancomycin. Gram negative rods were sensitive to, aminoglycosides, chloramphenicol, quinolones, piperacillin-tazobactum and cefoperazone-sulbactum, but were resistant to cephalosporins including third generation cephalosporins. Treatment with oral antibiotic was not successful. Patients responded well to open drainage via a stab incision away from the breast mound; 4 patients were managed by repeated needle aspirations. IV antibiotics were prescribed in all patients for 2-5 days, followed by oral continuation therapy of 7-14 days. From our study, we can conclude that parental counseling to avoid massage, and early treatment for pustulosis is important to prevent mastitis. Intravenous antibiotics should be used for this condition guided by gram stain or culture sensitivity once available. Empirically a drug with good anti-staph cover may be instituted till appropriate reports are available. Incision drainage gives uniformly good results, though; multiple sittings of needle drainage may obviate the need for incision drainage. Therapy can be shifted to oral drugs once clinical improvement is seen.
Instrumenting Beliefs in Threshold Public Goods
2016-01-01
Understanding the causal impact of beliefs on contributions in Threshold Public Goods (TPGs) is particularly important since the social optimum can be supported as a Nash Equilibrium and best-response contributions are a function of beliefs. Unfortunately, investigations of the impact of beliefs on behavior are plagued with endogeneity concerns. We create a set of instruments by cleanly and exogenously manipulating beliefs without deception. Tests indicate that the instruments are valid and relevant. Perhaps surprisingly, we fail to find evidence that beliefs are endogenous in either the one-shot or repeated-decision settings. TPG allocations are determined by a base contribution and beliefs in a one shot-setting. In the repeated-decision environment, once we instrument for first-round allocations, we find that second-round allocations are driven equally by beliefs and history. Moreover, we find that failing to instrument prior decisions overstates their importance. PMID:26859492
Volunteering as Red Queen Mechanism for Cooperation in Public Goods Games
NASA Astrophysics Data System (ADS)
Hauert, Christoph; De Monte, Silvia; Hofbauer, Josef; Sigmund, Karl
2002-05-01
The evolution of cooperation among nonrelated individuals is one of the fundamental problems in biology and social sciences. Reciprocal altruism fails to provide a solution if interactions are not repeated often enough or groups are too large. Punishment and reward can be very effective but require that defectors can be traced and identified. Here we present a simple but effective mechanism operating under full anonymity. Optional participation can foil exploiters and overcome the social dilemma. In voluntary public goods interactions, cooperators and defectors will coexist. We show that this result holds under very diverse assumptions on population structure and adaptation mechanisms, leading usually not to an equilibrium but to an unending cycle of adjustments (a Red Queen type of evolution). Thus, voluntary participation offers an escape hatch out of some social traps. Cooperation can subsist in sizable groups even if interactions are not repeated, defectors remain anonymous, players have no memory, and assortment is purely random.
Dunham, Kathryn J.; Shadi, Sarah; Sofko, Channing A.; Denney, Robert L.; Calloway, Jordan
2014-01-01
The aim of the current study was to compare two embedded measures of effort for the repeatable battery for the assessment of neuropsychological status (RBANS). Sensitivity and specificity of the Effort Index (EI) and Effort Scale (ES) were compared in a sample of individuals with genuine memory impairment (MI) and individuals coached to simulate MI. Overall, the EI yielded a sensitivity of 0.89 and specificity of 0.41, while the ES yielded a sensitivity of 0.88 and specificity of 0.81. When those in the MI group were separated by level of impairment, the EI was more specific when RBANS Total Scores were in the average or mildly impaired range, and the ES had greater specificity when RBANS Total Scores were in the severely impaired range. These results suggest that the embedded measure should be selected based on the level of impairment on the RBANS. PMID:25236719
Zhang, Pengfei; Li, Mingtao; Jiang, Xueguang; ...
2015-11-02
Polymerized ionic networks (PINs) with six ion pairs per repeating unit are synthesized by nucleophilic-substitution-mediated polymerization or radical polymerization of monomers bearing six 1-vinylimidazolium cations. PIN-based solid-like electrolytes show good ionic conductivities (up to 5.32 × 10 -3 S cm -1 at 22 °C), wide electrochemical stability windows (up to 5.6 V), and good interfacial compatibility with the electrodes.
Comparative peptidomics analysis of neural adaptations in rats repeatedly exposed to amphetamine.
Romanova, Elena V; Lee, Ji Eun; Kelleher, Neil L; Sweedler, Jonathan V; Gulley, Joshua M
2012-10-01
Repeated exposure to amphetamine (AMPH) induces long-lasting behavioral changes, referred to as sensitization, that are accompanied by various neuroadaptations in the brain. To investigate the chemical changes that occur during behavioral sensitization, we applied a comparative proteomics approach to screen for neuropeptide changes in a rodent model of AMPH-induced sensitization. By measuring peptide profiles with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and comparing signal intensities using principal component analysis and variance statistics, subsets of peptides are found with significant differences in the dorsal striatum, nucleus accumbens, and medial prefrontal cortex of AMPH-sensitized male Sprague-Dawley rats. These biomarker peptides, identified in follow-up analyses using liquid chromatography and tandem mass spectrometry, suggest that behavioral sensitization to AMPH is associated with complex chemical adaptations that regulate energy/metabolism, neurotransmission, apoptosis, neuroprotection, and neuritogenesis, as well as cytoskeleton integrity and neuronal morphology. Our data contribute to a growing number of reports showing that in addition to the mesolimbic dopamine system, which is the best known signaling pathway involved with reinforcing the effect of psychostimulants, concomitant chemical changes in other pathways and in neuronal organization may play a part in the overall effect of chronic AMPH exposure on behavior. © 2012 The Authors Journal of Neurochemistry © 2012 International Society for Neurochemistry.
Arnau, E G; Andersen, K E; Bruze, M; Frosch, P J; Johansen, J D; Menné, T; Rastogi, S C; White, I R; Lepoittevin, J P
2000-12-01
Fragrance materials are among the most common causes of allergic contact dermatitis. The aim of this study was to identify in a perfume fragrance allergens not included in the fragrance mix, by use of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships (SARs). The basis for the investigation was a 45-year-old woman allergic to her own perfume. She had a negative patch test to the fragrance mix and agreed to participate in the study. Chemical fractionation of the perfume concentrate was used for repeated patch testing and/or repeated open application test on the pre-sensitized patient. The chemical composition of the fractions giving a positive patch-test response and repeated open application test reactions was obtained by gas chromatography-mass spectrometry. From the compounds identified, those that contained a "structural alert" in their chemical structure, indicating an ability to modify skin proteins and thus behave as a skin sensitizer, were tested on the patient. The patient reacted positively to the synthetic fragrance p-t-butyl-alpha-methylhydrocinnamic aldehyde (Lilial), a widely used fragrance compound not present in the fragrance mix. The combination of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships seems to be a valuable tool for the investigation of contact allergy to fragrance materials.
Hoffmann, Sebastian
2015-01-01
The development of non-animal skin sensitization test methods and strategies is quickly progressing. Either individually or in combination, the predictive capacity is usually described in comparison to local lymph node assay (LLNA) results. In this process the important lesson from other endpoints, such as skin or eye irritation, to account for variability reference test results - here the LLNA - has not yet been fully acknowledged. In order to provide assessors as well as method and strategy developers with appropriate estimates, we investigated the variability of EC3 values from repeated substance testing using the publicly available NICEATM (NTP Interagency Center for the Evaluation of Alternative Toxicological Methods) LLNA database. Repeat experiments for more than 60 substances were analyzed - once taking the vehicle into account and once combining data over all vehicles. In general, variability was higher when different vehicles were used. In terms of skin sensitization potential, i.e., discriminating sensitizer from non-sensitizers, the false positive rate ranged from 14-20%, while the false negative rate was 4-5%. In terms of skin sensitization potency, the rate to assign a substance to the next higher or next lower potency class was approx.10-15%. In addition, general estimates for EC3 variability are provided that can be used for modelling purposes. With our analysis we stress the importance of considering the LLNA variability in the assessment of skin sensitization test methods and strategies and provide estimates thereof.
Colloidal GdVO4:Eu3+@SiO2 nanocrystals for highly selective and sensitive detection of Cu2+ ions
NASA Astrophysics Data System (ADS)
Liang, Yanjie; Noh, Hyeon Mi; Park, Sung Heum; Choi, Byung Chun; Jeong, Jung Hyun
2018-03-01
Nowadays, in view of health and safety demands, the controlled design of selective and sensitive sensors for Cu2+ detection is of considerable importance. Therefore, we construct herein core-shell colloidal GdVO4:Eu3+@SiO2 nanocrystals (NCs) as optical sensor for the detection of Cu2+, which were synthesized by a facile hydrothermal reaction and encapsulated with a uniform layer of ultrathin silica through a sol-gel strategy. The NCs present strong red emission due to energy transfer from VO43- groups to Eu3+ when exciting with ultraviolet (UV) light. This intense red emission from Eu3+ could be selectively quenched in the presence of Cu2+ in comparison to other metal ions and the limit of detection is as low as 80 nM in aqueous solution. It is revealed that the spectral overlap between the emission band of NCs and the absorption of Cu2+ accounts for this intriguing luminescence behavior. The detection ability is highly reversible by the addition of ethylenediaminetetraacetic acid (EDTA) with the recovery of almost 100% of the original luminescence. The luminescence quenching and recovery processes can be performed repeatedly with good sensing ability. These remarkable performances allow the colloidal GdVO4:Eu3+@SiO2 NCs a promising fluorescence chemosensor for detecting Cu2+ ions in aqueous solution.
Pira, Enrico; Romano, Canzio; Fresegna, Anna Maria; Ciervo, Aureliano; Buresti, Giuliana; Zoli, Wainer; Calistri, Daniele
2014-01-01
The aim of the present study was to identify sensitive and noninvasive biomarkers of early carcinogenic effect at target organ to use in biomonitoring studies of workers at risk for previous occupational exposure to potential carcinogens. Standard urine cytology (Papanicolaou staining test), comet assay, and quantitative telomerase repeat amplification protocol (TRAP) assay were performed in 159 ex-rubber workers employed in tyres production and 97 unexposed subjects. In TRAP positive cases, a second level analysis using FISH (Urovysion) was done. Cystoscopy results were available for 11 individuals whose 6 FISH/TRAP/comet positive showed in 3 cases a dysplastic condition confirmed by biopsy, 1 comet positive resulted in infiltrating UBC to the biopsy and with hyperplasia and slight dysplasia to the urinary cytology, 1 comet positive resulted in papillary superficial UBC to the biopsy, 1 FISH/TRAP positive showed a normal condition, and 2 TRAP positive showed in one case a phlogosis condition. The results evidenced good concordance of TRAP, comet, and FISH assays as early biomarkers of procarcinogenic effect confirmed by the dysplastic condition and UBC found by cystoscopy-biopsy analysis. The analysis of these markers in urine cells could be potentially more accurate than conventional cytology in monitoring workers exposed to mixture of bladder potential carcinogens. PMID:24877087
Huang, Youfang; Peng, Jinghe; Huang, Xiaojia
2018-04-20
In this work, magnetic carbon material derived from pomelo peels (MCMPs) was conveniently fabricated utilizing one-pot synthesis method and employed as adsorbent of magnetic solid-phase extraction (MSPE). Several characterized measures including infrared spectroscopy, scanning electron microscopy, transmission electron microscopy and vibrating sample magnetometer were used to investigate the morphology, spectroscopic and magnetic properties of prepared adsorbent. Apolar parabens and polar fluoroquinolones (FQs) were used to investigate the extraction performance of MCMPs. Under the optimized extraction conditions, the MCMPs displayed satisfactory extraction performance for target analytes. At the same time, the MCMPs/MSPE was combined with HPLC-DAD for the sensitive determination of parabens and FQs in real-life water samples. Results showed that the limits of detection (S/N = 3) for parabens and FQs were in the ranges of 0.011-0.053 μg/L and 0.012-0.46 μg/L, respectively. The spiked recoveries were in the range of 76.6-116% for parabens and 80.2-114% for FQs with good repeatability (relative standard deviations less than 10%). In comparison to reported methods, the developed MCMPs/MSPE-HPLC-DAD showed some merits including low-cost, simplicity, satisfactory sensitivity and green non-pollution. Copyright © 2018 Elsevier B.V. All rights reserved.
Polo, Maria; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael
2007-08-01
A solid-phase microextraction method (SPME) followed by gas chromatography with micro electron capture detection for determining trace levels of nitro musk fragrances in residual waters was optimized. Four nitro musks, musk xylene, musk moskene, musk tibetene and musk ketone, were selected for the optimization of the method. Factors affecting the extraction process were studied using a multivariate approach. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using two fiber coatings [Carboxen-polydimethylsiloxane (CAR/PDMS) and polydimethylsiloxane-divinylbenzene (PDMS/DVB)] selected among five commercial tested fibers. Sample agitation and the salting-out effect were also factors studied. The main effects and interactions between the factors were studied for all the target compounds. An extraction temperature of 100 degrees C and sampling the headspace over the sample, using either CAR/PDMS or PDMS/DVB as fiber coatings, were found to be the experimental conditions that led to a more effective extraction. High sensitivity, with detection limits in the low nanogram per liter range, and good linearity and repeatability were achieved for all nitro musks. Since the method proposed performed well for real samples, it was applied to different water samples, including wastewater and sewage, in which some of the target compounds (musk xylene and musk ketone) were detected and quantified.
Cavallo, Delia; Casadio, Valentina; Bravaccini, Sara; Iavicoli, Sergio; Pira, Enrico; Romano, Canzio; Fresegna, Anna Maria; Maiello, Raffaele; Ciervo, Aureliano; Buresti, Giuliana; Zoli, Wainer; Calistri, Daniele
2014-01-01
The aim of the present study was to identify sensitive and noninvasive biomarkers of early carcinogenic effect at target organ to use in biomonitoring studies of workers at risk for previous occupational exposure to potential carcinogens. Standard urine cytology (Papanicolaou staining test), comet assay, and quantitative telomerase repeat amplification protocol (TRAP) assay were performed in 159 ex-rubber workers employed in tyres production and 97 unexposed subjects. In TRAP positive cases, a second level analysis using FISH (Urovysion) was done. Cystoscopy results were available for 11 individuals whose 6 FISH/TRAP/comet positive showed in 3 cases a dysplastic condition confirmed by biopsy, 1 comet positive resulted in infiltrating UBC to the biopsy and with hyperplasia and slight dysplasia to the urinary cytology, 1 comet positive resulted in papillary superficial UBC to the biopsy, 1 FISH/TRAP positive showed a normal condition, and 2 TRAP positive showed in one case a phlogosis condition. The results evidenced good concordance of TRAP, comet, and FISH assays as early biomarkers of procarcinogenic effect confirmed by the dysplastic condition and UBC found by cystoscopy-biopsy analysis. The analysis of these markers in urine cells could be potentially more accurate than conventional cytology in monitoring workers exposed to mixture of bladder potential carcinogens.
Chen, Lei; Mei, Meng; Huang, Xiaojia; Yuan, Dongxing
2016-05-15
A simple, sensitive and environmentally friendly method using polymeric ionic liquid-based stir cake sorptive extraction followed by high performance liquid chromatography with diode array detection (HPLC/DAD) has been developed for efficient quantification of six selected estrogens in environmental waters. To extract trace estrogens effectively, a poly (1-ally-3-vinylimidazolium chloride-co-ethylene dimethacrylate) monolithic cake was prepared and used as the sorbent of stir cake sorptive extraction (SCSE). The effects of preparation conditions of sorbent and extraction parameters of SCSE for estrogens were investigated and optimized. Under optimal conditions, the developed method showed satisfactory analytical performance for targeted analytes. Low limits of detection (S/N=3) and quantification limits (S/N=10) were achieved within the range of 0.024-0.057 µg/L and 0.08-0.19 µg/L, respectively. Good linearity of method was obtained for analytes with the correlation coefficients (R(2)) above 0.99. At the same time, satisfactory method repeatability and reproducibility was achieved in terms of intra- and inter-day precisions, respectively. Finally, the established SCSE-HPLC/DAD method was successfully applied for the determination of estrogens in different environmental water samples. Recoveries obtained for the determination of estrogens in spiked samples ranged from 71.2% to 108%, with RSDs below 10% in all cases. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Kaihuan; Fan, Guokang; Hu, Ruifen; Li, Guang
2015-01-01
Noble metals addition on nanostructured metal oxides is an attractive way to enhance gas sensing properties. Herein, hierarchical zinc oxide (ZnO) porous microspheres decorated with cubic gold particles (Au particles) were synthesized using a facile hydrothermal method. The as-prepared Au-decorated ZnO was then utilized as the sensing film of a gas sensor based on a quartz crystal microbalance (QCM). This fabricated sensor was applied to detect dibutyl phthalate (DBP), which is a widely used plasticizer, and its coating load was optimized. When tested at room temperature, the sensor exhibited a high sensitivity of 38.10 Hz/ppb to DBP in a low concentration range from 2 ppb to 30 ppb and the calculated theoretical detection limit is below 1 ppb. It maintains good repeatability as well as long-term stability. Compared with the undecorated ZnO based QCM, the Au-decorated one achieved a 1.62-time enhancement in sensitivity to DBP, and the selectivity was also improved. According to the experimental results, Au-functionalized ZnO porous microspheres displayed superior sensing performance towards DBP, indicating its potential use in monitoring plasticizers in the gaseous state. Moreover, Au decoration of porous metal oxide nanostructures is proved to be an effective approach for enhancing the gas sensing properties and the corresponding mechanism was investigated. PMID:26343661