Sample records for sensitivity negative predictive

  1. Performance of the dipstick screening test as a predictor of negative urine culture

    PubMed Central

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086

  2. Maternal Sensitivity Predicts Fewer Sleep Problems at Early Adolescence for Toddlers with Negative Emotionality: A Case of Differential Susceptibility.

    PubMed

    Conway, Anne; Modrek, Anahid; Gorroochurn, Prakash

    2018-02-01

    Theory underscores the importance of parenting in sleep development, but few studies have examined whether links vary by temperament. To address this gap, we tested whether potential links between early maternal sensitivity and early adolescent sleep problems varied by child negative emotionality and delay of gratification. Using data from the National Institute of Child Health and Human Development Study of Early Child Care and Youth Development (N = 820), we found that high maternal sensitivity predicted fewer bedtime problems and longer sleep duration at 6th grade for toddlers with high negative emotionality, whereas low maternal sensitivity predicted the reverse. No differences were observed for low negative emotionality. Moreover, delay of gratification predicted fewer bedtime problems at 6th grade, but did not moderate associations between maternal sensitivity, negative emotionality, and sleep. Findings demonstrate that high, but not low, negative emotionality renders toddlers differentially susceptible and receptive to maternal sensitivity in relation to sleep.

  3. Negative urgency and reward/punishment sensitivity in intermittent explosive disorder.

    PubMed

    Puhalla, Alexander A; Ammerman, Brooke A; Uyeji, Lauren L; Berman, Mitchell E; McCloskey, Michael S

    2016-09-01

    Intermittent explosive disorder (IED) is the sole psychiatric diagnosis in which affective aggression is the cardinal symptom. Previous research has been equivocal with regard to the relationship between IED and impulsivity. This inconsistency may reflect the varied facets of impulsivity, with some aspects of impulsivity (e.g. negative urgency) as well as some overlapping, albeit distinct constructs (e.g. reward and punishment sensitivity) yet to be studied. The present study compared individuals diagnosed with IED (n=81) with psychiatric controls (PCs; n=52) and healthy volunteers (HVs; n=58) on the impulsivity domains of negative and positive urgency, perseverance, sensation seeking, and premeditation, as well as on reward and punishment sensitivity. We hypothesized that individuals with IED would show greater negative and positive urgency, reward sensitivity, punishment sensitivity, with negative urgency independently predicting IED status. We also hypothesized that negative urgency would predict levels of anger, aggression, and aggression control among those with IED. The IED participants reported greater negative urgency than both comparison groups, and greater levels of positive urgency, reward sensitivity, and punishment sensitivity compared to HVs. Further, heightened negative urgency was the sole predictor an IED diagnosis. Within the IED group negative urgency uniquely predicted decreased aggression control and increased trait anger. Limitations included reliance on self-report measures to assess RS/PS, impulsivity, and aggression. These findings suggest that negative urgency is a key factor associated with IED and is associated with dampened control of aggression within those with IED. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Cardiothoracic ratio for prediction of left ventricular dilation: a systematic review and pooled analysis.

    PubMed

    Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit

    2015-03-01

    Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.

  5. Mothers' depressive symptoms predict both increased and reduced negative reactivity: aversion sensitivity and the regulation of emotion.

    PubMed

    Dix, Theodore; Moed, Anat; Anderson, Edward R

    2014-07-01

    This study examined whether, as mothers' depressive symptoms increase, their expressions of negative emotion to children increasingly reflect aversion sensitivity and motivation to minimize ongoing stress or discomfort. In multiple interactions over 2 years, negative affect expressed by 319 mothers and their children was observed across variations in mothers' depressive symptoms, the aversiveness of children's immediate behavior, and observed differences in children's general negative reactivity. As expected, depressive symptoms predicted reduced maternal negative reactivity when child behavior was low in aversiveness, particularly with children who were high in negative reactivity. Depressive symptoms predicted high negative reactivity and steep increases in negative reactivity as the aversiveness of child behavior increased, particularly when high and continued aversiveness from the child was expected (i.e., children were high in negative reactivity). The findings are consistent with the proposal that deficits in parenting competence as depressive symptoms increase reflect aversion sensitivity and motivation to avoid conflict and suppress children's aversive behavior. © The Author(s) 2014.

  6. Sensitivity and specificity of subacute computerized neurocognitive testing and symptom evaluation in predicting outcomes after sports-related concussion.

    PubMed

    Lau, Brian C; Collins, Michael W; Lovell, Mark R

    2011-06-01

    Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.

  7. Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.

    PubMed

    Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.

  8. Translation, adaptation, and validation of the Sunderland Scale and the Cubbin & Jackson Revised Scale in Portuguese

    PubMed Central

    Sousa, Bruno

    2013-01-01

    Objective To translate into Portuguese and evaluate the measuring properties of the Sunderland Scale and the Cubbin & Jackson Revised Scale, which are instruments for evaluating the risk of developing pressure ulcers during intensive care. Methods This study included the process of translation and adaptation of the scales to the Portuguese language, as well as the validation of these tools. To assess the reliability, Cronbach alpha values of 0.702 to 0.708 were identified for the Sunderland Scale and the Cubbin & Jackson Revised Scale, respectively. The validation criteria (predictive) were performed comparatively with the Braden Scale (gold standard), and the main measurements evaluated were sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve, which were calculated based on cutoff points. Results The Sunderland Scale exhibited 60% sensitivity, 86.7% specificity, 47.4% positive predictive value, 91.5% negative predictive value, and 0.86 for the area under the curve. The Cubbin & Jackson Revised Scale exhibited 73.3% sensitivity, 86.7% specificity, 52.4% positive predictive value, 94.2% negative predictive value, and 0.91 for the area under the curve. The Braden scale exhibited 100% sensitivity, 5.3% specificity, 17.4% positive predictive value, 100% negative predictive value, and 0.72 for the area under the curve. Conclusions Both tools demonstrated reliability and validity for this sample. The Cubbin & Jackson Revised Scale yielded better predictive values for the development of pressure ulcers during intensive care. PMID:23917975

  9. A 3-Year Study of Predictive Factors for Positive and Negative Appendicectomies.

    PubMed

    Chang, Dwayne T S; Maluda, Melissa; Lee, Lisa; Premaratne, Chandrasiri; Khamhing, Srisongham

    2018-03-06

    Early and accurate identification or exclusion of acute appendicitis is the key to avoid the morbidity of delayed treatment for true appendicitis or unnecessary appendicectomy, respectively. We aim (i) to identify potential predictive factors for positive and negative appendicectomies; and (ii) to analyse the use of ultrasound scans (US) and computed tomography (CT) scans for acute appendicitis. All appendicectomies that took place at our hospital from the 1st of January 2013 to the 31st of December 2015 were retrospectively recorded. Test results of potential predictive factors of acute appendicitis were recorded. Statistical analysis was performed using Fisher exact test, logistic regression analysis, sensitivity, specificity, and positive and negative predictive values calculation. 208 patients were included in this study. 184 patients had histologically proven acute appendicitis. The other 24 patients had either nonappendicitis pathology or normal appendix. Logistic regression analysis showed statistically significant associations between appendicitis and white cell count, neutrophil count, C-reactive protein, and bilirubin. Neutrophil count was the test with the highest sensitivity and negative predictive values, whereas bilirubin was the test with the highest specificity and positive predictive values (PPV). US and CT scans had high sensitivity and PPV for diagnosing appendicitis. No single test was sufficient to diagnose or exclude acute appendicitis by itself. Combining tests with high sensitivity (abnormal neutrophil count, and US and CT scans) and high specificity (raised bilirubin) may predict acute appendicitis more accurately.

  10. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    PubMed

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.

  11. Streamlining the Evaluation of Low Back Pain in Children

    PubMed Central

    Auerbach, Joshua D.; Ahn, Jaimo; Zgonis, Miltiadis H.; Reddy, Sudheer C.; Ecker, Malcolm L.

    2008-01-01

    The workup of low back pain in children often results in overimaging so as not to miss organic back pain. The primary goal of this study was to identify which combination of imaging modalities provides the most sensitive and specific screening protocol for children with low back pain. Medical records from 100 consecutive patients between 2 and 18 years of age presenting with low back pain, without night pain or constitutional symptoms, were evaluated. A hyperextension test combined with a radiograph showed a negative predictive value of 0.81 and sensitivity of 0.90. The addition of a bone scan was highly effective in achieving good negative predictive value and sensitivity. Bone scans had perfect negative predictive value and sensitivity when symptom duration was less than 6 weeks. We identified a set of factors that is highly predictive for distinguishing organic back pain from mechanical back pain. Painless hyperextension combined with negative anteroposterior, lateral, and oblique lumbar radiographs and magnetic resonance images predicts mechanical back pain. For patients with nonneurologic back pain of less than 6 weeks duration, bone scan is the most useful screening test because it is accurate, accessible, inexpensive, and unlikely to require sedation. Level of Evidence: Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18553213

  12. Benefit of hepatitis C virus core antigen assay in prediction of therapeutic response to interferon and ribavirin combination therapy.

    PubMed

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.

  13. [Validation of the abbreviated Zarit scales for measuring burden syndrome in the primary caregiver of an elderly patient].

    PubMed

    Vélez Lopera, Johana María; Berbesí Fernández, Dedsy; Cardona Arango, Doris; Segura Cardona, Angela; Ordóñez Molina, Jaime

    2012-07-01

    To determine which abbreviated Zarit Scale (ZS) better evaluates the burden of the caregiver of an elderly patient in Medellin, Colombia. Validation study. Primary Care setting in the city of Medellin. Primary caregiver of dependent elderly patients over 65 years old. Sensitivity, specificity, positive predictive value, and negative predictive value for the different abbreviated Zarit scales, plus performing a reliability analysis using the Cronbach Alpha coefficient. The abbreviated scales obtained a sensitivity of between 36.84 and 81.58%, specificity between 95.99 and 100%, positive predictive values between 71.05 and 100%, and negative predictive values of between 91.64 and 97.42%. The scale that better determined caregiver burden in Primary Care was the Bedard Screening scale, with a sensitivity of 81.58%, a specificity of 96.35% and positive and negative predictive values of 75.61% and 97.42%, respectively. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  14. A novel QSAR model of Salmonella mutagenicity and its application in the safety assessment of drug impurities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valencia, Antoni; Prous, Josep; Mora, Oscar

    As indicated in ICH M7 draft guidance, in silico predictive tools including statistically-based QSARs and expert analysis may be used as a computational assessment for bacterial mutagenicity for the qualification of impurities in pharmaceuticals. To address this need, we developed and validated a QSAR model to predict Salmonella t. mutagenicity (Ames assay outcome) of pharmaceutical impurities using Prous Institute's Symmetry℠, a new in silico solution for drug discovery and toxicity screening, and the Mold2 molecular descriptor package (FDA/NCTR). Data was sourced from public benchmark databases with known Ames assay mutagenicity outcomes for 7300 chemicals (57% mutagens). Of these data, 90%more » was used to train the model and the remaining 10% was set aside as a holdout set for validation. The model's applicability to drug impurities was tested using a FDA/CDER database of 951 structures, of which 94% were found within the model's applicability domain. The predictive performance of the model is acceptable for supporting regulatory decision-making with 84 ± 1% sensitivity, 81 ± 1% specificity, 83 ± 1% concordance and 79 ± 1% negative predictivity based on internal cross-validation, while the holdout dataset yielded 83% sensitivity, 77% specificity, 80% concordance and 78% negative predictivity. Given the importance of having confidence in negative predictions, an additional external validation of the model was also carried out, using marketed drugs known to be Ames-negative, and obtained 98% coverage and 81% specificity. Additionally, Ames mutagenicity data from FDA/CFSAN was used to create another data set of 1535 chemicals for external validation of the model, yielding 98% coverage, 73% sensitivity, 86% specificity, 81% concordance and 84% negative predictivity. - Highlights: • A new in silico QSAR model to predict Ames mutagenicity is described. • The model is extensively validated with chemicals from the FDA and the public domain. • Validation tests show desirable high sensitivity and high negative predictivity. • The model predicted 14 reportedly difficult to predict drug impurities with accuracy. • The model is suitable to support risk evaluation of potentially mutagenic compounds.« less

  15. Optical coherence tomography in the diagnosis of dysplasia and adenocarcinoma in Barret's esophagus

    NASA Astrophysics Data System (ADS)

    Gladkova, N. D.; Zagaynova, E. V.; Zuccaro, G.; Kareta, M. V.; Feldchtein, F. I.; Balalaeva, I. V.; Balandina, E. B.

    2007-02-01

    Statistical analysis of endoscopic optical coherence tomography (EOCT) surveillance of 78 patients with Barrett's esophagus (BE) is presented in this study. The sensitivity of OCT device in retrospective open detection of early malignancy (including high grade dysplasia and intramucosal adenocarcinoma (IMAC)) was 75%, specificity 82%, diagnostic accuracy - 80%, positive predictive value- 60%, negative predictive value- 87%. In the open recognition of IMAC sensitivity was 81% and specificity were 85% each. Results of a blind recognition with the same material were similar: sensitivity - 77%, specificity 85%, diagnostic accuracy - 82%, positive predictive value- 70%, negative predictive value- 87%. As the endoscopic detection of early malignancy is problematic, OCT holds great promise in enhancing the diagnostic capability of clinical GI endoscopy.

  16. The sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm that minimizes computerized tomography.

    PubMed

    Arbuthnot, Mary; Mooney, David P

    2017-01-01

    It is crucial to identify cervical spine injuries while minimizing ionizing radiation. This study analyzes the sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm. We performed a retrospective review of all children <21years old who were admitted following blunt trauma and underwent cervical spine clearance utilizing our institution's cervical spine clearance algorithm over a 10-year period. Age, gender, International Classification of Diseases 9th Edition diagnosis codes, presence or absence of cervical collar on arrival, Injury Severity Score, and type of cervical spine imaging obtained were extracted from the trauma registry and electronic medical record. Descriptive statistics were used and the sensitivity and negative predictive value of the algorithm were calculated. Approximately 125,000 children were evaluated in the Emergency Department and 11,331 were admitted. Of the admitted children, 1023 patients arrived in a cervical collar without advanced cervical spine imaging and were evaluated using the cervical spine clearance algorithm. Algorithm sensitivity was 94.4% and the negative predictive value was 99.9%. There was one missed injury, a spinous process tip fracture in a teenager maintained in a collar. Our algorithm was associated with a low missed injury rate and low CT utilization rate, even in children <3years old. IV. Published by Elsevier Inc.

  17. Diagnostic accuracy of 3.0 T magnetic resonance imaging for the detection of meniscus posterior root pathology.

    PubMed

    LaPrade, Robert F; Ho, Charles P; James, Evan; Crespo, Bernardo; LaPrade, Christopher M; Matheny, Lauren M

    2015-01-01

    The purpose of this study was to determine the diagnostic accuracy of 3 T MRI, including sensitivity, specificity, negative and positive predictive values, for detection of posterior medial and lateral meniscus root tears and avulsions. All patients who had a 3 T MRI of the knee, followed by arthroscopic surgery, were included in this study. Arthroscopy was considered the gold standard. Meniscus root tears diagnosed at arthroscopy and on MRI were defined as a complete meniscus root detachment within 9 mm of the root. All surgical data were collected prospectively and stored in a data registry. MRI exams were reported prospectively by a musculoskeletal radiologist and reviewed retrospectively. There were 287 consecutive patients (156 males, 131 females; mean age 41.7 years) in this study. Prevalence of meniscus posterior root tears identified at arthroscopy was 9.1, 5.9% for medial and 3.5% for lateral root tears (one patient had both). Sensitivity was 0.770 (95% CI 0.570, 0.901), specificity was 0.729 (95% CI 0.708, 0.741), positive predictive value was 0.220 (95% CI 0.163, 0.257) and negative predictive value was 0.970 (95% CI 0.943, 0.987). For medial root tears, sensitivity was 0.824 (95% CI 0.569, 0.953), specificity was 0.800 (95% CI 0.784, 0.808), positive predictive value was 0.206 (95% CI 0.142, 0.238) and negative predictive value was 0.986 (95% CI 0.967, 0.996). For lateral meniscus posterior root tears, sensitivity was 0.600 (95% CI 0.281, 0.860), specificity was 0.903 (95% CI 0.891, 0.912), positive predictive value was 0.181 (95% CI 0.085, 0.261) and negative predictive value was 0.984 (95% CI 0.972, 0.994). This study demonstrated moderate sensitivity and specificity of 3 T MRI to detect posterior meniscus root tears. The negative predictive value of 3 T MRI to detect posterior meniscus root tears was high; however, the positive predictive value was low. Sensitivity was higher for medial root tears, indicating a higher risk of missing lateral root tears on MRI. Imaging has an important role in identifying meniscus posterior horn root tears; however, some root tears may not be identified until arthroscopy. Prognostic study (diagnostic), Level II.

  18. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    PubMed

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Evaluation of in silico tools to predict the skin sensitization potential of chemicals.

    PubMed

    Verheyen, G R; Braeken, E; Van Deun, K; Van Miert, S

    2017-01-01

    Public domain and commercial in silico tools were compared for their performance in predicting the skin sensitization potential of chemicals. The packages were either statistical based (Vega, CASE Ultra) or rule based (OECD Toolbox, Toxtree, Derek Nexus). In practice, several of these in silico tools are used in gap filling and read-across, but here their use was limited to make predictions based on presence/absence of structural features associated to sensitization. The top 400 ranking substances of the ATSDR 2011 Priority List of Hazardous Substances were selected as a starting point. Experimental information was identified for 160 chemically diverse substances (82 positive and 78 negative). The prediction for skin sensitization potential was compared with the experimental data. Rule-based tools perform slightly better, with accuracies ranging from 0.6 (OECD Toolbox) to 0.78 (Derek Nexus), compared with statistical tools that had accuracies ranging from 0.48 (Vega) to 0.73 (CASE Ultra - LLNA weak model). Combining models increased the performance, with positive and negative predictive values up to 80% and 84%, respectively. However, the number of substances that were predicted positive or negative for skin sensitization in both models was low. Adding more substances to the dataset will increase the confidence in the conclusions reached. The insights obtained in this evaluation are incorporated in a web database www.asopus.weebly.com that provides a potential end user context for the scope and performance of different in silico tools with respect to a common dataset of curated skin sensitization data.

  20. Benefit of Hepatitis C Virus Core Antigen Assay in Prediction of Therapeutic Response to Interferon and Ribavirin Combination Therapy

    PubMed Central

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay. PMID:15634970

  1. Attachment Insecurity Predicts Punishment Sensitivity in Anorexia Nervosa.

    PubMed

    Keating, Charlotte; Castle, David J; Newton, Richard; Huang, Chia; Rossell, Susan L

    2016-10-01

    Individuals with anorexia nervosa (AN) experience insecure attachment. We investigated whether insecure attachment is associated with punishment and reward sensitivity in women with AN. Women with AN (n = 24) and comparison women (n = 26) (CW) completed The Eating Disorder Examination Questionnaire, Depression Anxiety Stress Scale, The Attachment Style Questionnaire, and Sensitivity to Punishment/Sensitivity to Reward Questionnaire. Participants with AN returned higher ratings for insecure attachment (anxious and avoidant) experiences and greater sensitivity to punishment (p = 0.001) than CW. In AN, sensitivity to punishment was positively correlated with anxious attachment and negative emotionality but not eating disorder symptoms. Regression analysis revealed that anxious attachment independently predicted punishment sensitivity in AN. Anxious attachment experiences are related to punishment sensitivity in AN, independent of negative emotionality and eating disorder symptoms. Results support ongoing investigation of the contribution of attachment experiences in treatment and recovery.

  2. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    PubMed Central

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using random forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers were 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the ScoreCard database of possible skin or sense organ toxicants as primary candidates for experimental validation. PMID:25560674

  3. USE OF SCORE AND CEREBROSPINAL FLUID LACTATE DOSAGE IN DIFFERENTIAL DIAGNOSIS OF BACTERIAL AND ASEPTIC MENINGITIS.

    PubMed

    Pires, Frederico Ribeiro; Franco, Andréia Christine Bonotto Farias; Gilio, Alfredo Elias; Troster, Eduardo Juan

    2017-01-01

    To evaluate Bacterial Meningitis Score (BMS) on its own and in association with Cerebrospinal Fluid (CSF) lactate dosage in order to distinguish bacterial from aseptic meningitis. Children diagnosed with meningitis at a tertiary hospital between January/2011 and December/2014 were selected. All data were obtained upon admission. BMS was applied and included: CSF Gram staining (2 points); CSF neutrophil count ≥1,000 cells/mm3 (1 point); CSF protein ≥80 mg/dL (1 point); peripheral blood neutrophil count ≥10,000 cells/mm3 (1 point) and seizures upon/before arrival (1 point). Cutoff value for CSF lactate was ≥30 mg/dL. Sensitivity, specificity and negative predictive value of several BMS cutoffs and BMS associated with high CSF lactate were evaluated for prediction of bacterial meningitis. Among 439 eligible patients, 94 did not have all data available to complete the score, and 345 patients were included: 7 in bacterial meningitis group and 338 in aseptic meningitis group. As predictive factors of bacterial meningitis, BMS ≥1 had 100% sensitivity (95%CI 47.3-100), 64.2% specificity (58.8-100) and 100% negative predictive value (97.5-100); BMS ≥2 or BMS ≥1 associated with high CSF lactate also showed 100% sensitivity (47.3-100); but 98.5% specificity (96.6-99.5) and 100% negative predictive value (98.3-100). 2 point BMS in association with CSF lactate dosage had the same sensitivity and negative predictive value, with increased specificity for diagnosis of bacterial meningitis when compared with 1-point BMS.

  4. Comparison of bronchoalveolar lavage cytology and transbronchial biopsy in the diagnosis of carcinoma of lung.

    PubMed

    Ahmed, Ayesha; Ahmed, Sajjad

    2004-01-01

    The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.

  5. Accuracy of ultrasound for the prediction of placenta accreta.

    PubMed

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-08-01

    Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.

  6. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  7. Combined use of late phase dimercapto-succinic acid renal scintigraphy and ultrasound as first line screening after urinary tract infection in children.

    PubMed

    Quirino, Isabel G; Silva, Jose Maria P; Diniz, Jose S; Lima, Eleonora M; Rocha, Ana Cristina S; Simões e Silva, Ana Cristina; Oliveira, Eduardo A

    2011-01-01

    The aim of this study was to evaluate the diagnostic accuracy of dimercapto-succinic acid renal scintigraphy and renal ultrasound in identifying high grade vesicoureteral reflux in children after a first episode of urinary tract infection. A total of 533 children following a first urinary tract infection were included in the analysis. Patients were assessed by 3 diagnostic imaging studies, renal ultrasound, dimercapto-succinic acid scan and voiding cystourethrography. The main event of interest was the presence of high grade (III to V) vesicoureteral reflux. The combined and separate diagnostic accuracy of screening methods was assessed by calculation of diagnostic OR, sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratio. A total of 246 patients had reflux, of whom 144 (27%) had high grade (III to V) disease. Sensitivity, negative predictive value and diagnostic OR of ultrasound for high grade reflux were 83.3%, 90.8% and 7.9, respectively. Dimercapto-succinic acid scan had the same sensitivity as ultrasound but a higher negative predictive value (91.7%) and diagnostic OR (10.9). If both tests were analyzed in parallel by using the OR rule, ie a negative diagnosis was established only when both test results were normal, sensitivity increased to 97%, negative predictive value to 97% and diagnostic OR to 25.3. Only 9 children (6.3%) with dilating reflux had an absence of alterations in both tests. Our findings support the idea that ultrasound and dimercapto-succinic acid scan used in combination are reliable predictors of dilating vesicoureteral reflux. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Record of hospitalizations for ambulatory care sensitive conditions: validation of the hospital information system.

    PubMed

    Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa

    2013-01-01

    To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.

  9. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alves, Vinicius M.; Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599; Muratov, Eugene

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putativemore » sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative chemical hazards in the Scorecard database were found using our models.« less

  10. Should gram stains have a role in diagnosing hip arthroplasty infections?

    PubMed

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  11. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    PubMed Central

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Background Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. Objective To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. Methods In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). Results The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m2. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Conclusion Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction. PMID:24061685

  12. Sensitivity, specificity and predictive values of anterior chamber tap in cases of bacterial endophthalmitis.

    PubMed

    Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul

    2017-01-01

    To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p  = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p  < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.

  13. Maternal and child correlates of anxiety in 2½-year-old children.

    PubMed

    Mount, Kristin S; Crockenberg, Susan C; Jó, Patricia S Bárrig; Wagar, Jessica-Lyn

    2010-12-01

    The goal of this study was to predict the development of anxiety in 2½ year olds as a function of maternal anxiety and child inhibited temperament, and to test the mediating, moderating, and curvilinear effects of maternal sensitivity. Participants were 83 mothers and their 2½-year-old children (32 females). Maternal anxiety, child inhibition, and child anxiety were assessed by maternal report. Maternal sensitivity was rated based on the appropriateness and timeliness of mothers' responses to children's fear observed during their exposure to novel events in the laboratory and from mothers' diaries documenting their responses to children's fear in everyday situations. Gender predicted child anxiety, with mothers reporting girls as more anxious, as did child inhibition, with more inhibited children exhibiting more anxiety. Maternal sensitivity predicted child anxiety as a main effect and, in addition, inhibition moderated the curvilinear association of maternal sensitivity and child anxiety. For highly inhibited children, maternal sensitivity predicted anxiety in both a negative linear and a curvilinear fashion; anxiety decreased as maternal sensitivity increased up to a moderately high level, then increased at very high levels of maternal sensitivity. For less inhibited children, maternal sensitivity showed only a significant negative linear association with child anxiety. Copyright © 2010. Published by Elsevier Inc.

  14. USE OF SCORE AND CEREBROSPINAL FLUID LACTATE DOSAGE IN DIFFERENTIAL DIAGNOSIS OF BACTERIAL AND ASEPTIC MENINGITIS

    PubMed Central

    Pires, Frederico Ribeiro; Franco, Andréia Christine Bonotto Farias; Gilio, Alfredo Elias; Troster, Eduardo Juan

    2017-01-01

    ABSTRACT Objective: To evaluate Bacterial Meningitis Score (BMS) on its own and in association with Cerebrospinal Fluid (CSF) lactate dosage in order to distinguish bacterial from aseptic meningitis. Methods: Children diagnosed with meningitis at a tertiary hospital between January/2011 and December/2014 were selected. All data were obtained upon admission. BMS was applied and included: CSF Gram staining (2 points); CSF neutrophil count ≥1,000 cells/mm3 (1 point); CSF protein ≥80 mg/dL (1 point); peripheral blood neutrophil count ≥10,000 cells/mm3 (1 point) and seizures upon/before arrival (1 point). Cutoff value for CSF lactate was ≥30 mg/dL. Sensitivity, specificity and negative predictive value of several BMS cutoffs and BMS associated with high CSF lactate were evaluated for prediction of bacterial meningitis. Results: Among 439 eligible patients, 94 did not have all data available to complete the score, and 345 patients were included: 7 in bacterial meningitis group and 338 in aseptic meningitis group. As predictive factors of bacterial meningitis, BMS ≥1 had 100% sensitivity (95%CI 47.3-100), 64.2% specificity (58.8-100) and 100% negative predictive value (97.5-100); BMS ≥2 or BMS ≥1 associated with high CSF lactate also showed 100% sensitivity (47.3-100); but 98.5% specificity (96.6-99.5) and 100% negative predictive value (98.3-100). Conclusions: 2 point BMS in association with CSF lactate dosage had the same sensitivity and negative predictive value, with increased specificity for diagnosis of bacterial meningitis when compared with 1-point BMS. PMID:29185620

  15. Infant frontal EEG asymmetry in relation with postnatal maternal depression and parenting behavior.

    PubMed

    Wen, D J; Soe, N N; Sim, L W; Sanmugam, S; Kwek, K; Chong, Y-S; Gluckman, P D; Meaney, M J; Rifkin-Graboi, A; Qiu, A

    2017-03-14

    Right frontal electroencephalogram (EEG) asymmetry associates with negative affect and depressed mood, which, among children, are predicted by maternal depression and poor parenting. This study examined associations of maternal depression and maternal sensitivity with infant frontal EEG asymmetry based on 111 mother-6-month-infant dyads. There were no significant effects of postnatal maternal depression or maternal sensitivity, or their interaction, on infant EEG frontal asymmetry. However, in a subsample for which the infant spent at least 50% of his/her day time hours with his/her mother, both lower maternal sensitivity and higher maternal depression predicted greater relative right frontal EEG asymmetry. Our study further showed that greater relative right frontal EEG asymmetry of 6-month-old infants predicted their greater negative emotionality at 12 months of age. Our study suggested that among infants with sufficient postnatal maternal exposure, both maternal sensitivity and mental health are important influences on early brain development.

  16. [Evaluation of performance of five bioinformatics software for the prediction of missense mutations].

    PubMed

    Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen

    2016-10-01

    To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.

  17. [Development and validation of an algorithm to identify cancer recurrences from hospital data bases].

    PubMed

    Manzanares-Laya, S; Burón, A; Murta-Nascimento, C; Servitja, S; Castells, X; Macià, F

    2014-01-01

    Hospital cancer registries and hospital databases are valuable and efficient sources of information for research into cancer recurrences. The aim of this study was to develop and validate algorithms for the detection of breast cancer recurrence. A retrospective observational study was conducted on breast cancer cases from the cancer registry of a third level university hospital diagnosed between 2003 and 2009. Different probable cancer recurrence algorithms were obtained by linking the hospital databases and the construction of several operational definitions, with their corresponding sensitivity, specificity, positive predictive value and negative predictive value. A total of 1,523 patients were diagnosed of breast cancer between 2003 and 2009. A request for bone gammagraphy after 6 months from the first oncological treatment showed the highest sensitivity (53.8%) and negative predictive value (93.8%), and a pathology test after 6 months after the diagnosis showed the highest specificity (93.8%) and negative predictive value (92.6%). The combination of different definitions increased the specificity and the positive predictive value, but decreased the sensitivity. Several diagnostic algorithms were obtained, and the different definitions could be useful depending on the interest and resources of the researcher. A higher positive predictive value could be interesting for a quick estimation of the number of cases, and a higher negative predictive value for a more exact estimation if more resources are available. It is a versatile and adaptable tool for other types of tumors, as well as for the needs of the researcher. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.

  18. Performance characteristics of broth-only cultures after revision total joint arthroplasty.

    PubMed

    Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P

    2014-11-01

    Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  19. The role of negative affectivity and negative reactivity to emotions in predicting outcomes in the unified protocol for the transdiagnostic treatment of emotional disorders.

    PubMed

    Sauer-Zavala, Shannon; Boswell, James F; Gallagher, Matthew W; Bentley, Kate H; Ametaj, Amantia; Barlow, David H

    2012-09-01

    The present study aimed to understand the contributions of both the trait tendency to experience negative emotions and how one relates to such experience in predicting symptom change during participation in the Unified Protocol (UP), a transdiagnostic treatment for emotional disorders. Data were derived from a randomized controlled trial comparing the UP to a waitlist control/delayed-treatment condition. First, effect sizes of pre- to post-treatment change for frequency of negative emotions and several variables measuring reactivity to emotional experience (emotional awareness and acceptance, fear of emotions, and anxiety sensitivity) were examined. Second, the relative contributions of change in negative emotions and emotional reactivity in predicting symptom (clinician-rated anxiety, depression, and severity of principal diagnosis) reductions were investigated. Results suggested that decreases in the frequency of negative emotions and reactivity to emotions following participation in the UP were both large in magnitude. Further, two emotional reactivity variables (fear of emotions and anxiety sensitivity) remained significantly related to symptom outcomes when controlling for negative emotions, and accounted for significant incremental variance in their prediction. These findings lend support to the notion that psychological health depends less on the frequency of negative emotions and more on how one relates to these emotions when they occur. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. The value of negative Chlamydia trachomatis antibody in prediction of normal tubes in infertile women.

    PubMed

    Raoofi, Z; Barchinegad, M; Haghighi, L

    2013-01-01

    To evaluate the value of Chlamydia trachomatis antibody testing in prediction of at least one normal tube in infertile women. Eighty infertile women without any history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis were recruited in this cross-sectional study from 2009 to 2010. The patients underwent hysterosalpingography, laparoscopy, and anti Chlamydia trachomatis IgG antibody (CAT) testing. We compared laparoscopy findings and CAT regarding sensitivity, specificity, accuracy, and predicting value of tubal conditions. The CAT was positive in 50 patients (62.5%) and laparoscopy was positive in 32 patients (40%). The CAT was significantly higher in women with tubal disease (1.88 +/- 0.34) versus in women with normal tubes (1.21 +/- 0.28) (p = 0.003). Five out of 30 sero-negative women had unilateral tubal abnormality and none of them had bilateral tubal obstruction or severe pelvic adhesion. The sensitivity, specificity, positive and negative predictive value, and accuracy of the CAT in prediction of one normal tube were 100%, 42.25%, 18%, 100%, and 48.75%, respectively. The negative predictive value of CAT to predict at least one normal tube in infertile women without history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis was 100%.

  1. GENOMIC PREDICTOR OF RESPONSE AND SURVIVAL FOLLOWING TAXANE-ANTHRACYCLINE CHEMOTHERAPY FOR INVASIVE BREAST CANCER

    PubMed Central

    Hatzis, Christos; Pusztai, Lajos; Valero, Vicente; Booser, Daniel J.; Esserman, Laura; Lluch, Ana; Vidaurre, Tatiana; Holmes, Frankie; Souchon, Eduardo; Martin, Miguel; Cotrina, José; Gomez, Henry; Hubbard, Rebekah; Chacón, J. Ignacio; Ferrer-Lozano, Jaime; Dyer, Richard; Buxton, Meredith; Gong, Yun; Wu, Yun; Ibrahim, Nuhad; Andreopoulou, Eleni; Ueno, Naoto T.; Hunt, Kelly; Yang, Wei; Nazario, Arlene; DeMichele, Angela; O’Shaughnessy, Joyce; Hortobagyi, Gabriel N.; Symmans, W. Fraser

    2017-01-01

    CONTEXT Accurate prediction of who will (or won’t) have high probability of survival benefit from standard treatments is fundamental for individualized cancer treatment strategies. OBJECTIVE To develop a predictor of response and survival from chemotherapy for newly diagnosed invasive breast cancer. DESIGN Development of different predictive signatures for resistance and response to neoadjuvant chemotherapy (stratified according to estrogen receptor (ER) status) from gene expression microarrays of newly diagnosed breast cancer (310 patients). Then prediction of breast cancer treatment-sensitivity using the combination of signatures for: 1) sensitivity to endocrine therapy, 2) chemo-resistance, and 3) chemo-sensitivity. Independent validation (198 patients) and comparison with other reported genomic predictors of chemotherapy response. SETTING Prospective multicenter study to develop and test genomic predictors for neoadjuvant chemotherapy. PATIENTS Newly diagnosed HER2-negative breast cancer treated with chemotherapy containing sequential taxane and anthracycline-based regimens then endocrine therapy (if hormone receptor-positive). MAIN OUTCOME MEASURES Distant relapse-free survival (DRFS) if predicted treatment-sensitive and absolute risk reduction (ARR, difference in DRFS of the two predicted groups) at median follow-up (3 years), and their 95% confidence intervals (CI). RESULTS Patients in the independent validation cohort (99% clinical Stage II–III) who were predicted to be treatment-sensitive (28% of total) had DRFS of 92% (CI 85–100) and survival benefit compared to others (absolute risk reduction (ARR) 18%; CI 6–28). Predictions were accurate if breast cancer was ER-positive (30% predicted sensitive, DRFS 97%, CI 91–100; ARR 11%, CI 0.1–21) or ER-negative (26% predicted sensitive, DRFS 83%, CI 68–100; ARR 26%, CI 4–28), and were significant in multivariate analysis after adjusting for relevant clinical-pathologic characteristics. Other genomic predictors showed paradoxically worse survival if predicted to be responsive to chemotherapy. CONCLUSION A genomic predictor combining ER status, predicted chemo-resistance, predicted chemo-sensitivity, and predicted endocrine sensitivity accurately identified patients with survival benefit following taxane-anthracycline chemotherapy. PMID:21558518

  2. The accuracy of HIV rapid testing in integrated bio-behavioral surveys of men who have sex with men across 5 Provinces in South Africa

    PubMed Central

    Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian

    2017-01-01

    Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474

  3. Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers

    PubMed Central

    2015-01-01

    Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. PMID:26109105

  4. Intra-Operative Frozen Sections for Ovarian Tumors – A Tertiary Center Experience

    PubMed Central

    Arshad, Nur Zaiti Md; Ng, Beng Kwang; Paiman, Noor Asmaliza Md; Mahdy, Zaleha Abdullah; Noor, Rushdan Mohd

    2018-01-01

    Background: Accuracy of diagnosis with intra-operative frozen sections is extremely important in the evaluation of ovarian tumors so that appropriate surgical procedures can be selected. Study design: All patients who with intra-operative frozen sections for ovarian masses in a tertiary center over nine years from June 2008 until April 2017 were reviewed. Frozen section diagnosis and final histopathological reports were compared. Main outcome measures: Sensitivity, specificity, positive and negative predictive values of intra-operative frozen section as compared to final histopathological results for ovarian tumors. Results: A total of 92 cases were recruited for final evaluation. The frozen section diagnoses were comparable with the final histopathological reports in 83.7% of cases. The sensitivity, specificity, positive predictive value and negative predictive value for benign and malignant ovarian tumors were 95.6%, 85.1%, 86.0% and 95.2% and 69.2%, 100%, 100% and 89.2% respectively. For borderline ovarian tumors, the sensitivity and specificity were 76.2% and 88.7%, respectively; the positive predictive value was 66.7% and the negative predictive value was 92.7%. Conclusion: The accuracy of intra-operative frozen section diagnoses for ovarian tumors is high and this approach remains a reliable option in assessing ovarian masses intra-operatively. PMID:29373916

  5. Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?

    PubMed

    Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul

    2012-01-01

    BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.

  6. Periprosthetic infection: where do we stand with regard to Gram stain?

    PubMed

    Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert; Parvizi, Javad

    2009-02-01

    One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. A positive gram stain was defined as the visualization of bacterial cells or "many neutrophils" (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. The presence of organisms and "many" neutrophils on a Gram smear had high specificity (98-100%) and positive predictive value (89-100%) in both THA and TKA. The sensitivities (30-50%) and negative predictive values (70-79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43-64% and 82%, respectively). Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests.

  7. In monkeys making value-based decisions, amygdala neurons are sensitive to cue value as distinct from cue salience.

    PubMed

    Leathers, Marvin L; Olson, Carl R

    2017-04-01

    Neurons in the lateral intraparietal (LIP) area of macaque monkey parietal cortex respond to cues predicting rewards and penalties of variable size in a manner that depends on the motivational salience of the predicted outcome (strong for both large reward and large penalty) rather than on its value (positive for large reward and negative for large penalty). This finding suggests that LIP mediates the capture of attention by salient events and does not encode value in the service of value-based decision making. It leaves open the question whether neurons elsewhere in the brain encode value in the identical task. To resolve this issue, we recorded neuronal activity in the amygdala in the context of the task employed in the LIP study. We found that responses to reward-predicting cues were similar between areas, with the majority of reward-sensitive neurons responding more strongly to cues that predicted large reward than to those that predicted small reward. Responses to penalty-predicting cues were, however, markedly different. In the amygdala, unlike LIP, few neurons were sensitive to penalty size, few penalty-sensitive neurons favored large over small penalty, and the dependence of firing rate on penalty size was negatively correlated with its dependence on reward size. These results indicate that amygdala neurons encoded cue value under circumstances in which LIP neurons exhibited sensitivity to motivational salience. However, the representation of negative value, as reflected in sensitivity to penalty size, was weaker than the representation of positive value, as reflected in sensitivity to reward size. NEW & NOTEWORTHY This is the first study to characterize amygdala neuronal responses to cues predicting rewards and penalties of variable size in monkeys making value-based choices. Manipulating reward and penalty size allowed distinguishing activity dependent on motivational salience from activity dependent on value. This approach revealed in a previous study that neurons of the lateral intraparietal (LIP) area encode motivational salience. Here, it reveals that amygdala neurons encode value. The results establish a sharp functional distinction between the two areas. Copyright © 2017 the American Physiological Society.

  8. Molecular Nodal Staging Using miRNA Expression in Lung Cancer Patients by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration.

    PubMed

    Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro

    2018-06-13

    The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.

  9. Sensitivity, specificity, positive and negative predictive values: diagnosing purple mange.

    PubMed

    Collier, Jill; Huebscher, Roxana

    2010-04-01

    To shed light on several epidemiological terms for better understanding of diagnostic testing measures by using a mythical condition, "purple mange." Scientific literature related to epidemiology and statistical tests. Nurse practitioners (NPs) use the concepts of sensitivity (SEN), specificity (SPEC), positive predictive value (PPV), and negative predictive value (NPV) daily in primary care and specialty areas. In addition, PPV and NPV vary with the prevalence of a condition. At times, NPs misunderstand the meaning of these terms. In order to develop appropriate treatment plans, an understanding of the concepts of SEN, SPEC, PPV, and NPV is important for interpreting test results. The authors have used this mythical condition purple mange as a teaching tool for NP students.

  10. Performance of the dipstick screening test as a predictor of negative urine culture.

    PubMed

    Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle

    2017-01-01

    To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.

  11. Sensitivity, Specificity, and Public-Health Utility of Clinical Case Definitions Based on the Signs and Symptoms of Cholera in Africa.

    PubMed

    Nadri, Johara; Sauvageot, Delphine; Njanpop-Lafourcade, Berthe-Marie; Baltazar, Cynthia S; Banla Kere, Abiba; Bwire, Godfrey; Coulibaly, Daouda; Kacou N'Douba, Adele; Kagirita, Atek; Keita, Sakoba; Koivogui, Lamine; Landoh, Dadja E; Langa, Jose P; Miwanda, Berthe N; Mutombo Ndongala, Guy; Mwakapeje, Elibariki R; Mwambeta, Jacob L; Mengel, Martin A; Gessner, Bradford D

    2018-04-01

    During 2014, Africa reported more than half of the global suspected cholera cases. Based on the data collected from seven countries in the African Cholera Surveillance Network (Africhol), we assessed the sensitivity, specificity, and positive and negative predictive values of clinical cholera case definitions, including that recommended by the World Health Organization (WHO) using culture confirmation as the gold standard. The study was designed to assess results in real-world field situations in settings with recent cholera outbreaks or endemicity. From June 2011 to July 2015, a total of 5,084 persons with suspected cholera were tested for Vibrio cholerae in seven different countries of which 35.7% had culture confirmation. For all countries combined, the WHO case definition had a sensitivity = 92.7%, specificity = 8.1%, positive predictive value = 36.1%, and negative predictive value = 66.6%. Adding dehydration, vomiting, or rice water stools to the case definition could increase the specificity without a substantial decrease in sensitivity. Future studies could further refine our findings primarily by using more sensitive methods for cholera confirmation.

  12. Rapid detection of Mycobacterium tuberculosis and rifampicin resistance in extrapulmonary tuberculosis and sputum smear-negative pulmonary suspects using Xpert MTB/RIF.

    PubMed

    Ullah, Irfan; Javaid, Arshad; Masud, Haleema; Ali, Mazhar; Basit, Anila; Ahmad, Waqas; Younis, Faisal; Yasmin, Rehana; Khan, Afsar; Jabbar, Abdul; Husain, Masroor; Butt, Zahid Ahmad

    2017-04-01

    Tuberculosis (TB) is a serious public health problem in developing countries such as Pakistan. Rapid diagnosis of TB and detection of drug resistance are very important for timely and appropriate management of multidrug-resistant TB (MDR-TB). The purpose of this study was to determine the diagnostic efficacy of the Xpert MTB/RIF assay for rapid diagnosis of TB and detection of rifampicin (RIF) resistance in extrapulmonary and smear-negative pulmonary TB suspects. A total of 98 bronchoalveolar lavage fluid (BALF) and 168 extrapulmonary specimens were processed by Xpert MTB/RIF. Culture results are considered as the gold standard for diagnosis of TB, and drug susceptibility testing for detection of RIF resistance. Diagnostic efficacy was measured in terms of sensitivity, specificity and positive and negative predictive values. The Xpert MTB/RIF assay detected 40 (40.8 %) of 98 BALF of presumptive pulmonary TB and 60 (35.7 %) of 168 extrapulmonary specimens. Sensitivity and specificity of the Xpert MTB/RIF assay for detection of TB was 86 and 88.4 %, respectively. The positive predictive value was 71.5 % while negative predictive value was 95.1 %. The Xpert MTB/RIF assay is a rapid and simple technique with high sensitivity and specificity for diagnosing TB and detecting drug resistance in extrapulmonary and smear-negative TB cases.

  13. Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia

    PubMed Central

    Dinh, C H; Ng, R; Grandinetti, A; Joffe, A; Chow, D C

    2006-01-01

    Background An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gap's poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate ⩾2.5 mmol/l. Methods A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients' laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated. Results An anion gap ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively. Conclusions The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia. PMID:16858097

  14. Environmental Sensitivity in Children: Development of the Highly Sensitive Child Scale and Identification of Sensitivity Groups

    ERIC Educational Resources Information Center

    Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur

    2018-01-01

    A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…

  15. Non-animal assessment of skin sensitization hazard: Is an integrated testing strategy needed, and if so what should be integrated?

    PubMed

    Roberts, David W; Patlewicz, Grace

    2018-01-01

    There is an expectation that to meet regulatory requirements, and avoid or minimize animal testing, integrated approaches to testing and assessment will be needed that rely on assays representing key events (KEs) in the skin sensitization adverse outcome pathway. Three non-animal assays have been formally validated and regulatory adopted: the direct peptide reactivity assay (DPRA), the KeratinoSens™ assay and the human cell line activation test (h-CLAT). There have been many efforts to develop integrated approaches to testing and assessment with the "two out of three" approach attracting much attention. Here a set of 271 chemicals with mouse, human and non-animal sensitization test data was evaluated to compare the predictive performances of the three individual non-animal assays, their binary combinations and the "two out of three" approach in predicting skin sensitization potential. The most predictive approach was to use both the DPRA and h-CLAT as follows: (1) perform DPRA - if positive, classify as sensitizing, and (2) if negative, perform h-CLAT - a positive outcome denotes a sensitizer, a negative, a non-sensitizer. With this approach, 85% (local lymph node assay) and 93% (human) of non-sensitizer predictions were correct, whereas the "two out of three" approach had 69% (local lymph node assay) and 79% (human) of non-sensitizer predictions correct. The findings are consistent with the argument, supported by published quantitative mechanistic models that only the first KE needs to be modeled. All three assays model this KE to an extent. The value of using more than one assay depends on how the different assays compensate for each other's technical limitations. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Comparative study to assess whether high sensitive C-reactive protein and carotid intima media thickness improve the predictive accuracy of exercise stress testing for coronary artery disease in perimenopausal women with typical angina.

    PubMed

    Sinha, Dhurjati Prasad; Das, Munna; Banerjee, Amal Kumar; Ahmed, Shageer; Majumdar, Sonali

    2008-02-01

    Anginal symptoms are less predictive of abnormal coronary anatomy in women. The diagnostic accuracy of exercise treadmill test for obstructive coronary artery disease is less in young and middle aged women. High sensitive C-reactive protein has shown a strong and consistent relationship to the risk of incident cardiovascular events. Carotid intima media thickness is a non-invasive marker of atherosclerosis burden and also predicts prognosis in patients with coronary artery disease. We investigated whether incorporation of high sensitive C-reactive protein and carotid intima media thickness along with exercise stress results improved the predictive accuracy in perimenopausal non-diabetic women subset. Fifty perimenopausal non-diabetic patients (age 45 +/- 7 years) presenting with typical angina were subjected to treadmill test (Bruce protocol). Also carotid artery images at both sides of neck were acquired by B-mode ultrasound and carotid intima media thickness were measured. High sensitive C-reactive protein was measured. Of 50 patients, 22 had a positive exercise stress result. Coronary angiography done in all 50 patients revealed coronary artery disease in 10 patients with positive exercise stress result and in 4 patients with negative exercise stress result. Treadmill exercise stress test had a sensitivity of 71.4%, specificity of 66.7% and a negative predictive accuracy of 85.7% in this study group. High sensitive C-reactive protein in patients with documented coronary artery disease was not significantly different from those without coronary artery disease (4.8 +/- 0.9 mg/l versus 3.9 +/- 1.7 mg/l, p=NS). Also carotid intima media thickness was not significantly different between either of the groups with coronary artery disease positivity and negativity respectively (left: 1.25 +/- 0.55 versus 1.20 +/- 0.51 mm, p=NS; right:1.18 +/- 0.54 versus 1.15 +/- 0.41 mm, p=NS). High sensitive C-reactive protein and carotid intima media thickness were not helpful in further adding to the predictability of coronary artery disease in perimenopausal patients with typical angina as assessed by treadmill exercise stress test.

  17. Periprosthetic infection: where do we stand with regard to Gram stain?

    PubMed Central

    Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert

    2009-01-01

    Background and purpose One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. Materials and methods A positive gram stain was defined as the visualization of bacterial cells or “many neutrophils” (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. Results The presence of organisms and “many” neutrophils on a Gram smear had high specificity (98–100%) and positive predictive value (89–100%) in both THA and TKA. The sensitivities (30–50%) and negative predictive values (70–79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43–64% and 82%, respectively). Interpretation Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests. PMID:19297787

  18. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Development of an enzyme-linked immunosorbent assay for serodiagnosis of ringworm infection in cattle.

    PubMed

    Bagut, Elena Tatiana; Cambier, Ludivine; Heinen, Marie-Pierre; Cozma, Vasile; Monod, Michel; Mignon, Bernard

    2013-08-01

    The aim of this study was to develop an in-house enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of ringworm infection in cattle. We used available recombinant forms of Trichophyton rubrum dipeptidyl peptidase V (TruDppV) and T. rubrum leucin aminopeptidase 2 (TruLap2), which are 98% identical to Trichophyton verrucosum orthologues. Field serum samples from 135 cattle with ringworm infection, as confirmed by direct microscopy, fluorescence microscopy, and PCR, and from 55 cattle without any apparent skin lesions or history of ringworm infection that served as negative controls were used. Sensitivities, specificities, and positive and negative predictive values were determined to evaluate the diagnostic value of our ELISA. Overall, the ELISAs based on recombinant TruDppV and TruLap2 discriminated well between infected animals and healthy controls. Highly significant differences (P < 0.0001, Mann-Whitney U test) were noted between optical density values obtained when sera from infected versus control cattle were tested. The ELISA developed for the detection of specific antibodies against DppV gave 89.6% sensitivity, 92.7% specificity, a 96.8% positive predictive value, and a 78.4% negative predictive value. The recombinant TruLap2-based ELISA displayed 88.1% sensitivity, 90.9% specificity, a 95.9% positive predictive value, and a 75.7% negative predictive value. To the best of our knowledge, this is the first ELISA based on recombinant antigens for assessing immune responses to ringworm infection in cattle; it is particularly suitable for epidemiological studies and also for the evaluation of vaccines and/or vaccination procedures.

  20. Predictive value and construct validity of the work functioning screener-healthcare (WFS-H).

    PubMed

    Boezeman, Edwin J; Nieuwenhuijsen, Karen; Sluiter, Judith K

    2016-05-25

    To test the predictive value and convergent construct validity of a 6-item work functioning screener (WFS-H). Healthcare workers (249 nurses) completed a questionnaire containing the work functioning screener (WFS-H) and a work functioning instrument (NWFQ) measuring the following: cognitive aspects of task execution and general incidents, avoidance behavior, conflicts and irritation with colleagues, impaired contact with patients and their family, and level of energy and motivation. Productivity and mental health were also measured. Negative and positive predictive values, AUC values, and sensitivity and specificity were calculated to examine the predictive value of the screener. Correlation analysis was used to examine the construct validity. The screener had good predictive value, since the results showed that a negative screener score is a strong indicator of work functioning not hindered by mental health problems (negative predictive values: 94%-98%; positive predictive values: 21%-36%; AUC:.64-.82; sensitivity: 42%-76%; and specificity 85%-87%). The screener has good construct validity due to moderate, but significant (p<.001), associations with productivity (r=.51), mental health (r=.48), and distress (r=.47). The screener (WFS-H) had good predictive value and good construct validity. Its score offers occupational health professionals a helpful preliminary insight into the work functioning of healthcare workers.

  1. Dialysate bacterial endotoxin as a prognostic indicator of peritoneal dialysis related peritonitis.

    PubMed

    Szeto, Cheuk-Chun; Lai, Ka-Bik; Chow, Kai-Ming; Kwan, Bonnie Ching-Ha; Law, Man-Ching; Pang, Wing-Fai; Ma, Terry King-Wing; Leung, Chi-Bon; Li, Philip Kam-Tao

    2016-12-01

    Peritonitis is the major complication of peritoneal dialysis (PD). The aim of our present study is to explore the prognostic value of endotoxin level in PD effluent for the prediction of treatment failure in PD-related peritonitis. We studied 325 peritonitis episodes in 223 patients. PD effluent (PDE) was collected every 5 days for endotoxin level and leukocyte count. Patients were followed for relapsing or recurrent peritonitis. We found 20 episodes (6.2%) had primary treatment failure; 41 (12.6%) developed relapsing, 19 (5.8%) had recurrent, and 22 (6.8%) had repeat episodes. Endotoxin was detectable in the PDE of 19 episodes (24.4%) caused by Gram negative organisms, 4 episodes (6.8%) of mixed bacterial growth, and none of the culture negative episodes or those by Gram positive organisms. For episodes caused by Gram negative bacteria, a detectable endotoxin level in PDE on day 5 had a sensitivity and specificity of 66.7% and 83.3%, respectively, for predicting primary treatment failure. In contrast, PDE leukocyte count > 1000 per mm3 on day 5 had a sensitivity and specificity of 88.9% and 89.1%, respectively; the addition of PDE endotoxin assay did not improve the sensitivity or specificity. We conclude that detectable endotoxin in PDE 5 days after antibiotic therapy might predict primary treatment failure in peritonitis episodes caused by Gram negative organisms. However, the sensitivity and specificity of PDE endotoxin assay was inferior to PDE leukocyte count. © 2016 Asian Pacific Society of Nephrology.

  2. Sensitivity and Specificity of Procalcitonin in Predicting Bacterial Infections in Patients With Renal Impairment

    PubMed Central

    El-sayed, Dena; Grotts, Jonathan; Golgert, William A.; Sugar, Alan M.

    2014-01-01

    Background  It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Methods  Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18–65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m2, admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. Results  The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Conclusions  Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75. PMID:25734138

  3. Sensitivity and specificity of procalcitonin in predicting bacterial infections in patients with renal impairment.

    PubMed

    El-Sayed, Dena; Grotts, Jonathan; Golgert, William A; Sugar, Alan M

    2014-09-01

    It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18-65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m(2), admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75.

  4. The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a Screening Tool.

    PubMed

    Bastiaens, Leo; Galus, James

    2018-03-01

    The DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure was developed to aid clinicians with a dimensional assessment of psychopathology; however, this measure resembles a screening tool for several symptomatic domains. The objective of the current study was to examine the basic parameters of sensitivity, specificity, positive and negative predictive power of the measure as a screening tool. One hundred and fifty patients in a correctional community center filled out the measure prior to a psychiatric evaluation, including the Mini International Neuropsychiatric Interview screen. The above parameters were calculated for the domains of depression, mania, anxiety, and psychosis. The results showed that the sensitivity and positive predictive power of the studied domains was poor because of a high rate of false positive answers on the measure. However, when the lowest threshold on the Cross-Cutting Symptom Measure was used, the sensitivity of the anxiety and psychosis domains and the negative predictive values for mania, anxiety and psychosis were good. In conclusion, while it is foreseeable that some clinicians may use the DSM-5 Self-Rated Level 1 Cross-Cutting Symptom Measure as a screening tool, it should not be relied on to identify positive findings. It functioned well in the negative prediction of mania, anxiety and psychosis symptoms.

  5. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of operatively treated proximal femoral fractures seen in the study, sensitivity of CT was 60% (3/5) and negative predictive value was 97%, although the relatively few patients needing fixation precludes statistical analysis.

  6. Impact of axillary ultrasound and core needle biopsy on the utility of intraoperative frozen section analysis and treatment decision making in women with invasive breast cancer.

    PubMed

    Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B

    2012-09-01

    Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Childhood peer reputation as a predictor of competence and symptoms 10 years later.

    PubMed

    Gest, Scott D; Sesma, Arturo; Masten, Ann S; Tellegen, Auke

    2006-08-01

    This study examined the differential developmental significance of multiple domains of peer reputation in childhood for current and future competence and symptoms. Participants were 205 children from a normative school cohort who completed assessments in grades 3-6 and then again 10 years later. Through re-analysis of original data from the Revised Class Play (RCP; N=612), new narrow-band subscales were examined as distinct correlates and predictors of competence in age-relevant developmental tasks and psychological well being as indexed by internalizing symptoms. Findings support the differentiation of peer exclusion, withdrawal, and sadness within the broad sensitive-isolated domain of reputation, as well as the distinctive meaning of reputations for Popularity-Leadership and Prosocial Behavior within the broad Sociable-Leader domain. When the Sensitive-Isolated predictors were considered, academic and job competence at the 10-year follow-up were predicted uniquely and negatively by peer exclusion, problems in the social and romantic domains were predicted distinctively by withdrawal from peers, and internalizing symptoms were uniquely predicted by childhood reputation as Sad-Sensitive. When the Sociable-Leader predictors were considered, academic and (for ethnic minority youth) job success was predicted by a Prosocial reputation, social success was forecasted by Popularity-Leadership, and romantic competence was predicted positively by Popularity-Leadership and negatively by Prosocial reputation. Negative academic and job outcomes were also predicted by a childhood reputation as Aggressive-Disruptive. Results are discussed in relation to conceptualizing and measuring peer social competence and its relation to later adaptation.

  8. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  9. IATA for skin sensitization potential – 1 out of 2 or 2 out of 3? ...

    EPA Pesticide Factsheets

    To meet EU regulatory requirements and to avoid or minimize animal testing, there is a need for non-animal methods to assess skin sensitization potential. Given the complexity of the skin sensitization endpoint, there is an expectation that integrated testing and assessment approaches (IATA) will need to be developed which rely on assays representing key events in the pathway. Three non-animal assays have been formally validated: the direct peptide reactivity assay (DPRA), the KeratinoSensTM assay and the h-CLAT assay. At the same time, there have been many efforts to develop IATA with the “2 out of 3” approach attracting much attention whereby a chemical is classified on the basis of the majority outcome. A set of 271 chemicals with mouse, human and non-animal sensitization test data was evaluated to compare the predictive performances of the 3 individual non-animal assays, their binary combinations and the ‘2 out of 3’ approach. The analysis revealed that the most predictive approach was to use both the DPRA and h-CLAT: 1. Perform DPRA – if positive, classify as a sensitizer; 2. If negative, perform h-CLAT – a positive outcome denotes a sensitizer, a negative, a non-sensitizer. With this approach, 83% (LLNA) and 93% (human) of the non-sensitizer predictions were correct, in contrast to the ‘2 out of 3’ approach which had 69% (LLNA) and 79% (human) of non-sensitizer predictions correct. The views expressed are those of the authors and do not ne

  10. Predictive Value of Matrix Metalloproteinases and Their Inhibitors for Mortality in Septic Patients: A Cohort Study.

    PubMed

    Serrano-Gomez, Sergio; Burgos-Angulo, Gabriel; Niño-Vargas, Daniela Camila; Niño, María Eugenia; Cárdenas, María Eugenia; Chacón-Valenzuela, Estephania; McCosham, Diana Margarita; Peinado-Acevedo, Juan Sebastián; Lopez, M Marcos; Cunha, Fernando; Pazin-Filho, Antonio; Ilarraza, Ramses; Schulz, Richard; Torres-Dueñas, Diego

    2017-01-01

    Over 170 biomarkers are being investigated regarding their prognostic and diagnostic accuracy in sepsis in order to find new tools to reduce morbidity and mortality. Matrix metalloproteinases (MMPs) and their inhibitors have been recently studied as promising new prognostic biomarkers in patients with sepsis. This study is aimed at determining the utility of several cutoff points of these biomarkers to predict mortality in patients with sepsis. A multicenter, prospective, analytic cohort study was performed in the metropolitan area of Bucaramanga, Colombia. A total of 289 patients with sepsis and septic shock were included. MMP-9, MMP-2, tissue inhibitor of metalloproteinase 1 (TIMP-1), TIMP-2, TIMP-1/MMP-9 ratio, and TIMP-2/MMP-2 ratio were determined in blood samples. Value ranges were correlated with mortality to estimate sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiving operating characteristic curve. Sensitivity ranged from 33.3% (MMP-9/TIMP-1 ratio) to 60.6% (TIMP-1) and specificity varied from 38.8% (MMP-2/TIMP-2 ratio) to 58.5% (TIMP-1). As for predictive values, positive predictive value range was from 17.5% (MMP-9/TIMP-1 ratio) to 70.4% (MMP-2/TIMP-2 ratio), whereas negative predictive values were between 23.2% (MMP-2/TIMP-2 ratio) and 80.9% (TIMP-1). Finally, area under the curve scores ranged from 0.31 (MMP-9/TIMP-1 ratio) to 0.623 (TIMP-1). Although TIMP-1 showed higher sensitivity, specificity, and negative predictive value, with a representative population sample, we conclude that none of the evaluated biomarkers had significant predictive value for mortality.

  11. Validation of diabetes mellitus and hypertension diagnosis in computerized medical records in primary health care

    PubMed Central

    2011-01-01

    Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202

  12. Carotid bruit for detection of hemodynamically significant carotid stenosis: the Northern Manhattan Study

    PubMed Central

    Ratchford, Elizabeth V.; Jin, Zhezhen; Di Tullio, Marco R.; Salameh, Maya J.; Homma, Shunichi; Gan, Robert; Boden-Albala, Bernadette; Sacco, Ralph L.; Rundek, Tatjana

    2009-01-01

    Objective The prevalence of carotid bruits and the utility of auscultation for predicting carotid stenosis are not well known. We aimed to establish the prevalence of carotid bruits and the diagnostic accuracy of auscultation for detection of hemodynamically significant carotid stenosis, using carotid duplex as the gold standard. Methods The Northern Manhattan Study (NOMAS) is a prospective multiethnic community-based cohort designed to examine the incidence of stroke and other vascular events and the association between various vascular risk factors and subclinical atherosclerosis. Of the stroke-free cohort (n=3298), 686 were examined for carotid bruits and underwent carotid duplex. Main outcome measures included prevalence of carotid bruits and sensitivity, specificity, positive predictive value, negative predictive value and accuracy of auscultation for prediction of ipsilateral carotid stenosis. Results Among 686 subjects with a mean age of 68.2 ± 9.4 years, the prevalence of ≥60% carotid stenosis as detected by ultrasound was 2.2% and the prevalence of carotid bruits was 4.1%. For detection of carotid stenosis, sensitivity of auscultation was 56%, specificity was 98%, positive predictive value was 25%, negative predictive value was 99% and overall accuracy was 97.5%. Discussion In this ethnically diverse cohort, the prevalence of carotid bruits and hemodynamically significant carotid stenosis was low. Sensitivity and positive predictive value were also low, and the 44% false-negative rate suggests that auscultation is not sufficient to exclude carotid stenosis. While the presence of a bruit may still warrant further evaluation with carotid duplex, ultrasonography may be considered in high-risk asymptomatic patients, irrespective of findings on auscultation. PMID:19133168

  13. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    PubMed

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Origins of mother-child reminiscing style.

    PubMed

    Reese, Elaine; Meins, Elizabeth; Fernyhough, Charles; Centifanti, Luna

    2018-04-26

    Maternal elaborative reminiscing supports preschool children's autobiographical memory, self-concept, and emotion understanding. What are the factors contributing to mothers' elaborative style of reminiscing? In a longitudinal community sample (n = 170 at the final data point), this study explored the role of maternal depression (8-44 months), maternal sensitivity and maternal mind-mindedness (8 months), as well as child factors of joint attention (15 months), attachment security (15 months), and language (26 months) for mother-child reminiscing about a positive (happy) and a negative (scared) event at 44 months. Mothers could be classed into two groups of low versus increasing depression from 8 to 44 months, yet maternal depression did not uniquely predict mother-child reminiscing after accounting for maternal sensitivity and other factors. Instead, maternal sensitivity, children's joint attention, and language uniquely predicted children's elaborations about the scared event at 44 months, and maternal sensitivity uniquely predicted mothers' elaborations about the scared event at 44 months. Mothers who are more sensitive in early interactions may later be better at engaging their children when reminiscing about negative emotions. These findings have implications for the design of interventions targeted at supporting mothers to engage in elaborative reminiscing with their preschool children.

  15. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    PubMed

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  16. An investigation of new toxicity test method performance in validation studies: 1. Toxicity test methods that have predictive capacity no greater than chance.

    PubMed

    Bruner, L H; Carr, G J; Harbell, J W; Curren, R D

    2002-06-01

    An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.

  17. Specificity of disgust sensitivity in the prediction of fear and disgust responding to a brief spider exposure.

    PubMed

    Olatunji, Bunmi O; Deacon, Brett

    2008-01-01

    This study examined the specificity of disgust sensitivity in predicting fear and disgust responses to exposure to a spider. Participants high (n=22) and low (n=28) in spider fear completed self-report measures of disgust sensitivity, contamination fear, anxiety, and negative affect. They then participated in a behavioral avoidance task (BAT) in which they were briefly exposed to a realistic-looking, but fake, tarantula. Results revealed that disgust sensitivity was associated with fear and disgust responding to the BAT. The association between disgust sensitivity and disgust responding to the BAT remained significant after controlling for gender, spider fear group membership, contamination fear, anxiety, and negative affect. However, the association between disgust sensitivity and fear responding to the BAT was only marginally significant after controlling for the same variables. Contamination fear was also strongly related to fear and disgust responding to the BAT. However, this relationship was fully mediated by disgust sensitivity. These findings indicate that disgust sensitivity has a unique association with aversive responding to spiders. The implications of these findings for better understanding the complex role of fear and disgust as they related to disgust sensitivity in spider phobia are discussed.

  18. Vasospasm on transcranial Doppler is predictive of delayed cerebral ischemia in aneurysmal subarachnoid hemorrhage: a systematic review and meta-analysis.

    PubMed

    Kumar, Gyanendra; Shahripour, Reza Bavarsad; Harrigan, Mark R

    2016-05-01

    OBJECT The impact of transcranial Doppler (TCD) ultrasonography evidence of vasospasm on patient-centered clinical outcomes following aneurysmal subarachnoid hemorrhage (aSAH) is unknown. Vasospasm is known to lead to delayed cerebral ischemia (DCI) and poor outcomes. This systematic review and meta-analysis evaluates the predictive value of vasospasm on DCI, as diagnosed on TCD. METHODS MEDLINE, Scopus, the Cochrane trial register, and clinicaltrials.gov were searched through September 2014 using key words and the terms "subarachnoid hemorrhage," "aneurysm," "aneurysmal," "cerebral vasospasm," "vasospasm," "transcranial Doppler," and "TCD." Sensitivities, specificities, and positive and negative predictive values were pooled by a DerSimonian and Laird random-effects model. RESULTS Seventeen studies (n = 2870 patients) met inclusion criteria. The amount of variance attributable to heterogeneity was significant (I(2) > 50%) for all syntheses. No studies reported the impact of TCD evidence of vasospasm on functional outcome or mortality. TCD evidence of vasospasm was found to be highly predictive of DCI. Pooled estimates for TCD diagnosis of vasospasm (for DCI) were sensitivity 90% (95% confidence interval [CI] 77%-96%), specificity 71% (95% CI 51%-84%), positive predictive value 57% (95% CI 38%-71%), and negative predictive value 92% (95% CI 83%-96%). CONCLUSIONS TCD evidence of vasospasm is predictive of DCI with high accuracy. Although high sensitivity and negative predictive value make TCD an ideal monitoring device, it is not a mandated standard of care in aSAH due to the paucity of evidence on clinically relevant outcomes, despite recommendation by national guidelines. High-quality randomized trials evaluating the impact of TCD monitoring on patient-centered and physician-relevant outcomes are needed.

  19. Ottawa Ankle Rules and Subjective Surgeon Perception to Evaluate Radiograph Necessity Following Foot and Ankle Sprain

    PubMed Central

    Pires, RES; Pereira, AA; Abreu-e-Silva, GM; Labronici, PJ; Figueiredo, LB; Godoy-Santos, AL; Kfuri, M

    2014-01-01

    Background: Foot and ankle injuries are frequent in emergency departments. Although only a few patients with foot and ankle sprain present fractures and the fracture patterns are almost always simple, lack of fracture diagnosis can lead to poor functional outcomes. Aim: The present study aims to evaluate the reliability of the Ottawa ankle rules and the orthopedic surgeon subjective perception to assess foot and ankle fractures after sprains. Subjects and Methods: A cross-sectional study was conducted from July 2012 to December 2012. Ethical approval was granted. Two hundred seventy-four adult patients admitted to the emergency department with foot and/or ankle sprain were evaluated by an orthopedic surgeon who completed a questionnaire prior to radiographic assessment. The Ottawa ankle rules and subjective perception of foot and/or ankle fractures were evaluated on the questionnaire. Results: Thirteen percent (36/274) patients presented fracture. Orthopedic surgeon subjective analysis showed 55.6% sensitivity, 90.1% specificity, 46.5% positive predictive value and 92.9% negative predictive value. The general orthopedic surgeon opinion accuracy was 85.4%. The Ottawa ankle rules presented 97.2% sensitivity, 7.8% specificity, 13.9% positive predictive value, 95% negative predictive value and 19.9% accuracy respectively. Weight-bearing inability was the Ottawa ankle rule item that presented the highest reliability, 69.4% sensitivity, 61.6% specificity, 63.1% accuracy, 21.9% positive predictive value and 93% negative predictive value respectively. Conclusion: The Ottawa ankle rules showed high reliability for deciding when to take radiographs in foot and/or ankle sprains. Weight-bearing inability was the most important isolated item to predict fracture presence. Orthopedic surgeon subjective analysis to predict fracture possibility showed a high specificity rate, representing a confident method to exclude unnecessary radiographic exams. PMID:24971221

  20. The Feedback-Related Negativity and the P300 Brain Potential Are Sensitive to Price Expectation Violations in a Virtual Shopping Task.

    PubMed

    Schaefer, Alexandre; Buratto, Luciano G; Goto, Nobuhiko; Brotherhood, Emilie V

    A large body of evidence shows that buying behaviour is strongly determined by consumers' price expectations and the extent to which real prices violate these expectations. Despite the importance of this phenomenon, little is known regarding its neural mechanisms. Here we show that two patterns of electrical brain activity known to index prediction errors-the Feedback-Related Negativity (FRN) and the feedback-related P300 -were sensitive to price offers that were cheaper than participants' expectations. In addition, we also found that FRN amplitude time-locked to price offers predicted whether a product would be subsequently purchased or not, and further analyses suggest that this result was driven by the sensitivity of the FRN to positive price expectation violations. This finding strongly suggests that ensembles of neurons coding positive prediction errors play a critical role in real-life consumer behaviour. Further, these findings indicate that theoretical models based on the notion of prediction error, such as the Reinforcement Learning Theory, can provide a neurobiologically grounded account of consumer behavior.

  1. The Feedback-Related Negativity and the P300 Brain Potential Are Sensitive to Price Expectation Violations in a Virtual Shopping Task

    PubMed Central

    Schaefer, Alexandre; Buratto, Luciano G.; Goto, Nobuhiko; Brotherhood, Emilie V.

    2016-01-01

    A large body of evidence shows that buying behaviour is strongly determined by consumers’ price expectations and the extent to which real prices violate these expectations. Despite the importance of this phenomenon, little is known regarding its neural mechanisms. Here we show that two patterns of electrical brain activity known to index prediction errors–the Feedback-Related Negativity (FRN) and the feedback-related P300 –were sensitive to price offers that were cheaper than participants’ expectations. In addition, we also found that FRN amplitude time-locked to price offers predicted whether a product would be subsequently purchased or not, and further analyses suggest that this result was driven by the sensitivity of the FRN to positive price expectation violations. This finding strongly suggests that ensembles of neurons coding positive prediction errors play a critical role in real-life consumer behaviour. Further, these findings indicate that theoretical models based on the notion of prediction error, such as the Reinforcement Learning Theory, can provide a neurobiologically grounded account of consumer behavior. PMID:27658301

  2. B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones

    PubMed Central

    Harper, Jonathan D.; Hsi, Ryan S.; Shah, Anup R.; Dighe, Manjiri K.; Carter, Stephen J.; Moshiri, Mariam; Paun, Marla; Lu, Wei; Bailey, Michael R.

    2013-01-01

    Abstract Purpose To compare color Doppler twinkling artifact and B-mode ultrasonography in detecting kidney stones. Patients and Methods Nine patients with recent CT scans prospectively underwent B-mode and twinkling artifact color Doppler ultrasonography on a commercial ultrasound machine. Video segments of the upper pole, interpolar area, and lower pole were created, randomized, and independently reviewed by three radiologists. Receiver operator characteristics were determined. Results There were 32 stones in 18 kidneys with a mean stone size of 8.9±7.5 mm. B-mode ultrasonography had 71% sensitivity, 48% specificity, 52% positive predictive value, and 68% negative predictive value, while twinkling artifact Doppler ultrasonography had 56% sensitivity, 74% specificity, 62% positive predictive value, and 68% negative predictive value. Conclusions When used alone, B-mode is more sensitive, but twinkling artifact is more specific in detecting kidney stones. This information may help users employ twinkling and B-mode to identify stones and developers to improve signal processing to harness the fundamental acoustic differences to ultimately improve stone detection. PMID:23067207

  3. Exfoliative cytology: a helpful tool for the diagnosis of paracoccidioidomycosis.

    PubMed

    Cardoso, S V; Moreti, M M; Costa, I M; Loyola, A M

    2001-07-01

    To describe the main cytological findings associated with smears collected from oral lesions of paracoccidioidomycosis and to appraise the use of cytology as a diagnostic tool for the disease. Cytological smears and biopsies were collected from 40 lesions with a clinical suspicion of paracoccidioidomycosis. Evaluation of the sensitivity, specificity, positive and negative predictive values, accuracy and the positive likeness ratio of the oral smear when compared with the histological diagnosis, was performed. The latter is considered the 'gold standard' for comparison. The main morphological findings were the rounded-shaped, birefringent and multiple-budded fungi, Langhans' giant cells and epithelioid cells. The following associative measures were found: sensitivity, 67.9%; specificity, 91.7%; positive predictive value, 95.0%; negative predictive value, 55.0%; accuracy, 75.0%; and positive likeness ratio, 8.14. The cytological findings of paracoccidioidomycosis are characteristic and cytology is accurate in the diagnosis of the disease. Positive patients should be treated. Negative patients should be submitted to biopsy to confirm or to dismiss the diagnosis of this mycosis.

  4. A Sensitive and Specific Neural Signature for Picture-Induced Negative Affect

    PubMed Central

    Chang, Luke J.; Gianaros, Peter J.; Manuck, Stephen B.; Krishnan, Anjali; Wager, Tor D.

    2015-01-01

    Neuroimaging has identified many correlates of emotion but has not yet yielded brain representations predictive of the intensity of emotional experiences in individuals. We used machine learning to identify a sensitive and specific signature of emotional responses to aversive images. This signature predicted the intensity of negative emotion in individual participants in cross validation (n =121) and test (n = 61) samples (high–low emotion = 93.5% accuracy). It was unresponsive to physical pain (emotion–pain = 92% discriminative accuracy), demonstrating that it is not a representation of generalized arousal or salience. The signature was comprised of mesoscale patterns spanning multiple cortical and subcortical systems, with no single system necessary or sufficient for predicting experience. Furthermore, it was not reducible to activity in traditional “emotion-related” regions (e.g., amygdala, insula) or resting-state networks (e.g., “salience,” “default mode”). Overall, this work identifies differentiable neural components of negative emotion and pain, providing a basis for new, brain-based taxonomies of affective processes. PMID:26098873

  5. Assessment of Myometrial Invasion in Premenopausal Grade 1 Endometrial Carcinoma: Is Magnetic Resonance Imaging a Reliable Tool in Selecting Patients for Fertility-Preserving Therapy?

    PubMed

    Sakane, Makoto; Hori, Masatoshi; Onishi, Hiromitsu; Tsuboyama, Takahiro; Ota, Takashi; Tatsumi, Mitsuaki; Ueda, Yutaka; Kimura, Toshihiro; Kimura, Tadashi; Tomiyama, Noriyuki

    The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.

  6. The Accuracy of the Spot Sign and the Blend Sign for Predicting Hematoma Expansion in Patients with Spontaneous Intracerebral Hemorrhage.

    PubMed

    Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao

    2017-05-12

    BACKGROUND Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. MATERIAL AND METHODS Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. RESULTS A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). CONCLUSIONS Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy.

  7. The Accuracy of the Spot Sign and the Blend Sign for Predicting Hematoma Expansion in Patients with Spontaneous Intracerebral Hemorrhage

    PubMed Central

    Zheng, Jun; Yu, Zhiyuan; Xu, Zhao; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao

    2017-01-01

    Background Hematoma expansion is associated with poor outcome in intracerebral hemorrhage (ICH) patients. The spot sign and the blend sign are reliable tools for predicting hematoma expansion in ICH patients. The aim of this study was to compare the accuracy of the two signs in the prediction of hematoma expansion. Material/Methods Patients with spontaneous ICH were screened for the presence of the computed tomography angiography (CTA) spot sign and the non-contrast CT (NCCT) blend sign within 6 hours after onset of symptoms. The sensitivity, specificity, and positive and negative predictive values of the spot sign and the blend sign in predicting hematoma expansion were calculated. The accuracy of the spot sign and the blend sign in predicting hematoma expansion was analyzed by receiver-operator analysis. Results A total of 115 patients were enrolled in this study. The spot sign was observed in 25 (21.74%) patients, whereas the blend sign was observed in 22 (19.13%) patients. Of the 28 patients with hematoma expansion, the CTA spot sign was found on admission CT scans in 16 (57.14%) and the NCCT blend sign in 12 (42.86%), respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the spot sign for predicting hematoma expansion were 57.14%, 89.66%, 64.00%, and 86.67%, respectively. In contrast, the sensitivity, specificity, positive predictive value, and negative predictive value of the blend sign were 42.86%, 88.51%, 54.55%, and 82.80%, respectively. The area under the curve (AUC) of the spot sign was 0.734, which was higher than that of the blend sign (0.657). Conclusions Both the spot sign and the blend sign seemed to be good predictors for hematoma expansion, and the spot sign appeared to have better predictive accuracy. PMID:28498827

  8. The role of nerve monitoring to predict postoperative recurrent laryngeal nerve function in thyroid and parathyroid surgery.

    PubMed

    Eid, Issam; Miller, Frank R; Rowan, Stephanie; Otto, Randal A

    2013-10-01

    To determine the role and efficacy of intraoperative recurrent laryngeal nerve (RLN) stimulation in the prediction of early and permanent postoperative nerve function in thyroid and parathyroid surgery. A retrospective review of thyroid and parathyroid surgeries was performed with calculation of sensitivity and specificity of the response of intraoperative stimulation for different pathological groups. Normal electromyography (EMG) response with 0.5 mAmp stimulation was considered a positive stimulation response with postoperative function determined by laryngoscopy. No EMG response at >1-2 mAmps was considered a negative response. The rates of early and permanent paralysis, as well as sensitivity, specificity, and positive and negative predictive values for postoperative nerve function were calculated for separate pathological groups. The number of nerves at risk analyzed was 909. The overall early and permanent paralysis rates were 3.1% and 1.2%, respectively, with the highest rate being for Grave's disease cases. The overall sensitivity was 98.4%. The specificity was lower at 62.5% but acceptable in thyroid carcinoma and Grave's disease patients. The majority of nerves with a positive stimulation result and postoperative paralysis on laryngoscopy recovered function in 3 to 12 weeks, showing positive stimulation to be a good predictor of eventual recovery. Stimulation of the RLN during thyroid and parathyroid surgery is a useful tool in predicting postoperative RLN function. The sensitivity of stimulation is high, showing positive stimulation to be an excellent predictor of normal nerve function. Negative stimulation is more predictive of paralysis in cases of thyroid carcinoma and Grave's disease. 2b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    PubMed

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  10. Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

    PubMed

    Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada

    2002-08-01

    The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

  11. Social stress reactivity alters reward and punishment learning

    PubMed Central

    Frank, Michael J.; Allen, John J. B.

    2011-01-01

    To examine how stress affects cognitive functioning, individual differences in trait vulnerability (punishment sensitivity) and state reactivity (negative affect) to social evaluative threat were examined during concurrent reinforcement learning. Lower trait-level punishment sensitivity predicted better reward learning and poorer punishment learning; the opposite pattern was found in more punishment sensitive individuals. Increasing state-level negative affect was directly related to punishment learning accuracy in highly punishment sensitive individuals, but these measures were inversely related in less sensitive individuals. Combined electrophysiological measurement, performance accuracy and computational estimations of learning parameters suggest that trait and state vulnerability to stress alter cortico-striatal functioning during reinforcement learning, possibly mediated via medio-frontal cortical systems. PMID:20453038

  12. Social stress reactivity alters reward and punishment learning.

    PubMed

    Cavanagh, James F; Frank, Michael J; Allen, John J B

    2011-06-01

    To examine how stress affects cognitive functioning, individual differences in trait vulnerability (punishment sensitivity) and state reactivity (negative affect) to social evaluative threat were examined during concurrent reinforcement learning. Lower trait-level punishment sensitivity predicted better reward learning and poorer punishment learning; the opposite pattern was found in more punishment sensitive individuals. Increasing state-level negative affect was directly related to punishment learning accuracy in highly punishment sensitive individuals, but these measures were inversely related in less sensitive individuals. Combined electrophysiological measurement, performance accuracy and computational estimations of learning parameters suggest that trait and state vulnerability to stress alter cortico-striatal functioning during reinforcement learning, possibly mediated via medio-frontal cortical systems.

  13. Utility of urine lipoarabinomannan (LAM) in diagnosing tuberculosis and predicting mortality with and without HIV: prospective TB cohort from the Thailand Big City TB Research Network.

    PubMed

    Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat

    2017-06-01

    To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  14. Immunohistochemical expression of p16 in lipoblastomas.

    PubMed

    Cappellesso, Rocco; d'Amore, Emanuele S G; Dall'Igna, Patrizia; Guzzardo, Vincenza; Vassarotto, Elisa; Rugge, Massimo; Alaggio, Rita

    2016-01-01

    Lipoblastoma (LB) is a rare benign adipocytic tumor of childhood occasionally showing histological similarities to myxoid liposarcoma (ML) or well-differentiated liposarcoma (WDL). p16 immunohistochemistry has proved to be useful in distinguishing various types of liposarcomas, in particular WDL from lipoma, with higher sensitivity and specificity than MDM2 and CDK4 immunohistochemistry. In this study, we reported the histologic features of a series of 30 LB with emphasis on the potential diagnostic pitfalls and investigated the immunohistochemical expression of p16. Moreover, p16 immunostaining was performed in 16 liposarcomas (11 WDL and 5 ML), 16 lipomas, and 16 cases of liponecrosis in order to evaluate its usefulness in the differential diagnosis of challenging lesions occurring in older children. Overall, p16 immunostaining was positive in 3 LBs and in 12 out of 16 liposarcomas (10 WDL and 2 ML), with a sensitivity of 75%, a specificity of 90%, a positive predictive value of 80%, and a negative predictive value of 87%. All lipomas were p16 negative, whereas 5 liponecroses were positive. Accounting altogether the benign lesions versus liposarcomas, p16 showed a sensitivity of 75%, a specificity of 87%, a positive predictive value of 60%, and a negative predictive value of 93%. Our data suggest that a negative p16 immunostaining may be helpful in excluding a liposarcoma when occurring in unusual clinical contexts, such as in adolescence or late recurrence. However, such finding should be interpreted with caution since also some liposarcomas lack p16 and occasional LBs are positive. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis.

    PubMed

    Urabe, Naohisa; Sakamoto, Susumu; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-06-01

    We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. Copyright © 2017 American Society for Microbiology.

  16. Patterns of Sensitivity to Parenting and Peer Environments: Early Temperament and Adolescent Externalizing Behavior.

    PubMed

    Tung, Irene; Noroña, Amanda N; Morgan, Julia E; Caplan, Barbara; Lee, Steve S; Baker, Bruce L

    2018-03-14

    Although parenting behavior and friendship quality predict adolescent externalizing behaviors (EBs), individual differences in temperament may differentially affect susceptibility to these factors over time. In a multi-method and multi-informant study of 141 children followed prospectively from toddlerhood to adolescence, we tested the independent and interactive associations of age 3 reactive temperament (e.g., negative emotionality) and age 13 observed parenting (i.e., positive and negative behavior) and friendship (i.e., conflict and warmth), with multi-informant ratings of age 15 aggression and rule-breaking behavior. Negative parenting predicted growth in parent-rated EB, but only for adolescents with early reactive temperament. Temperament did not affect sensitivity to positive parenting or friendship. Results are discussed in the context of differential susceptibility theory and intervention implications for adolescents. © 2018 Society for Research on Adolescence.

  17. Comparison of diagnostic methods in the evaluation of onychomycosis.

    PubMed

    Haghani, Iman; Shokohi, Tahereh; Hajheidari, Zohreh; Khalilian, Alireza; Aghili, Seyed Reza

    2013-04-01

    Onychomycosis is a common nail problem, accounting for up to half of all nail diseases. Several nail disorders may mimic the onychomycosis clinically. Therefore, a sensitive, quick, and inexpensive test is essential for screening nail specimens for the administration of the proper drug. The aim of this study was to compare 4 different diagnostic methods in the evaluation of onychomycosis and to determine their sensitivity, specificity, positive predictive value, and negative predictive value. In a cross-sectional study, nail specimens were collected from 101 patients suspected to have onychomycosis during a 14-month period. The nail specimens were examined using potassium hydroxide (KOH) 20 %, KOH-treated nail clipping stained with periodic acid-Schiff (KONCPA), and calcofluor white (CFW) stain, and grew a fungal culture. The culture was chosen as the gold standard for statistical analysis using the McNemar and chi-square tests. Out of 101 patients, 100 (99 %) patients had at least 1 of the 4 diagnostic methods positive for the presence of organisms. The positive rates for the fungal culture, KOH preparation, CFW, and KONCPA were 74.2, 85.1, 91.09, and 99.01 %, respectively. The sensitivity and negative predictive value of KONCPA was 100 %. KONCPA was the most sensitive among the tests and was also superior to other methods in its negative predictive value. KONCPA was easy to perform, rapid, and gave significantly higher rates of detection of onychomycosis compared to the standard methods of KOH preparation and fungal culture. Therefore, KONCPA should be the single method of choice for the evaluation of onychomycosis.

  18. A Transient Dopamine Signal Represents Avoidance Value and Causally Influences the Demand to Avoid

    PubMed Central

    Pultorak, Katherine J.; Schelp, Scott A.; Isaacs, Dominic P.; Krzystyniak, Gregory

    2018-01-01

    Abstract While an extensive literature supports the notion that mesocorticolimbic dopamine plays a role in negative reinforcement, recent evidence suggests that dopamine exclusively encodes the value of positive reinforcement. In the present study, we employed a behavioral economics approach to investigate whether dopamine plays a role in the valuation of negative reinforcement. Using rats as subjects, we first applied fast-scan cyclic voltammetry (FSCV) to determine that dopamine concentration decreases with the number of lever presses required to avoid electrical footshock (i.e., the economic price of avoidance). Analysis of the rate of decay of avoidance demand curves, which depict an inverse relationship between avoidance and increasing price, allows for inference of the worth an animal places on avoidance outcomes. Rapidly decaying demand curves indicate increased price sensitivity, or low worth placed on avoidance outcomes, while slow rates of decay indicate reduced price sensitivity, or greater worth placed on avoidance outcomes. We therefore used optogenetics to assess how inducing dopamine release causally modifies the demand to avoid electrical footshock in an economic setting. Increasing release at an avoidance predictive cue made animals more sensitive to price, consistent with a negative reward prediction error (i.e., the animal perceives they received a worse outcome than expected). Increasing release at avoidance made animals less sensitive to price, consistent with a positive reward prediction error (i.e., the animal perceives they received a better outcome than expected). These data demonstrate that transient dopamine release events represent the value of avoidance outcomes and can predictably modify the demand to avoid. PMID:29766047

  19. Emotion, working memory task demands and individual differences predict behavior, cognitive effort and negative affect.

    PubMed

    Storbeck, Justin; Davidson, Nicole A; Dahl, Chelsea F; Blass, Sara; Yung, Edwin

    2015-01-01

    We examined whether positive and negative affect motivates verbal and spatial working memory processes, respectively, which have implications for the expenditure of mental effort. We argue that when emotion promotes cognitive tendencies that are goal incompatible with task demands, greater cognitive effort is required to perform well. We sought to investigate whether this increase in cognitive effort impairs behavioural control over a broad domain of self-control tasks. Moreover, we predicted that individuals with higher behavioural inhibition system (BIS) sensitivities would report more negative affect within the goal incompatible conditions because such individuals report higher negative affect during cognitive challenge. Positive or negative affective states were induced followed by completing a verbal or spatial 2-back working memory task. All participants then completed one of three self-control tasks. Overall, we observed that conditions of emotion and working memory incompatibility (positive/spatial and negative/verbal) performed worse on the self-control tasks, and within the incompatible conditions individuals with higher BIS sensitivities reported more negative affect at the end of the study. The combination of findings suggests that emotion and working memory compatibility reduces cognitive effort and impairs behavioural control.

  20. Evaluating emotional sensitivity and tolerance factors in the prediction of panic-relevant responding to a biological challenge.

    PubMed

    Kutz, Amanda; Marshall, Erin; Bernstein, Amit; Zvolensky, Michael J

    2010-01-01

    The current study investigated anxiety sensitivity, distress tolerance (Simons & Gaher, 2005), and discomfort intolerance (Schmidt, Richey, Cromer, & Buckner, 2007) in relation to panic-relevant responding (i.e., panic attack symptoms and panic-relevant cognitions) to a 10% carbon dioxide enriched air challenge. Participants were 216 adults (52.6% female; M(age)=22.4, SD=9.0). A series of hierarchical multiple regressions was conducted with covariates of negative affectivity and past year panic attack history in step one of the model, and anxiety sensitivity, discomfort intolerance, and distress tolerance entered simultaneously into step two. Results indicated that anxiety sensitivity, but not distress tolerance or discomfort intolerance, was significantly incrementally predictive of physical panic attack symptoms and cognitive panic attack symptoms. Additionally, anxiety sensitivity was significantly predictive of variance in panic attack status during the challenge. These findings emphasize the important, unique role of anxiety sensitivity in predicting risk for panic psychopathology, even when considered in the context of other theoretically relevant emotion vulnerability variables.

  1. Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers.

    PubMed

    Simon, Richard

    2015-08-01

    Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  2. Sensitivity, specificity, and predictive values of pediatric metabolic syndrome components in relation to adult metabolic syndrome: the Princeton LRC follow-up study.

    PubMed

    Huang, Terry T-K; Nansel, Tonja R; Belsheim, Allen R; Morrison, John A

    2008-02-01

    To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoff points in relation to adult MetS. Data from the National Heart, Lung, and Blood Institute Lipid Research Clinics Princeton Prevalence Study (1973-1976) and the Princeton Follow-up Study (2000-2004) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff point and for aggregates of components. Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all 5 pediatric MetS components were considered, the presence of at least 1 abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Considering multiple metabolic variables in childhood can improve the predictive usefulness for adult MetS, compared with each component or body mass alone. MetS variables may be useful for identifying some children who are at risk for prevention interventions.

  3. Can 3-dimensional power Doppler indices improve the prenatal diagnosis of a potentially morbidly adherent placenta in patients with placenta previa?

    PubMed

    Haidar, Ziad A; Papanna, Ramesha; Sibai, Baha M; Tatevian, Nina; Viteri, Oscar A; Vowels, Patricia C; Blackwell, Sean C; Moise, Kenneth J

    2017-08-01

    Traditionally, 2-dimensional ultrasound parameters have been used for the diagnosis of a suspected morbidly adherent placenta previa. More objective techniques have not been well studied yet. The objective of the study was to determine the ability of prenatal 3-dimensional power Doppler analysis of flow and vascular indices to predict the morbidly adherent placenta objectively. A prospective cohort study was performed in women between 28 and 32 gestational weeks with known placenta previa. Patients underwent a two-dimensional gray-scale ultrasound that determined management decisions. 3-Dimensional power Doppler volumes were obtained during the same examination and vascular, flow, and vascular flow indices were calculated after manual tracing of the viewed placenta in the sweep; data were blinded to obstetricians. Morbidly adherent placenta was confirmed by histology. Severe morbidly adherent placenta was defined as increta/percreta on histology, blood loss >2000 mL, and >2 units of PRBC transfused. Sensitivities, specificities, predictive values, and likelihood ratios were calculated. Student t and χ 2 tests, logistic regression, receiver-operating characteristic curves, and intra- and interrater agreements using Kappa statistics were performed. The following results were found: (1) 50 women were studied: 23 had morbidly adherent placenta, of which 12 (52.2%) were severe morbidly adherent placenta; (2) 2-dimensional parameters diagnosed morbidly adherent placenta with a sensitivity of 82.6% (95% confidence interval, 60.4-94.2), a specificity of 88.9% (95% confidence interval, 69.7-97.1), a positive predictive value of 86.3% (95% confidence interval, 64.0-96.4), a negative predictive value of 85.7% (95% confidence interval, 66.4-95.3), a positive likelihood ratio of 7.4 (95% confidence interval, 2.5-21.9), and a negative likelihood ratio of 0.2 (95% confidence interval, 0.08-0.48); (3) mean values of the vascular index (32.8 ± 7.4) and the vascular flow index (14.2 ± 3.8) were higher in morbidly adherent placenta (P < .001); (4) area under the receiver-operating characteristic curve for the vascular and vascular flow indices were 0.99 and 0.97, respectively; (5) the vascular index ≥21 predicted morbidly adherent placenta with a sensitivity and a specificity of 95% (95% confidence interval, 88.2-96.9) and 91%, respectively (95% confidence interval, 87.5-92.4), 92% positive predictive value (95% confidence interval, 85.5-94.3), 90% negative predictive value (95% confidence interval, 79.9-95.3), positive likelihood ratio of 10.55 (95% confidence interval, 7.06-12.75), and negative likelihood ratio of 0.05 (95% confidence interval, 0.03-0.13); and (6) for the severe morbidly adherent placenta, 2-dimensional ultrasound had a sensitivity of 33.3% (95% confidence interval, 11.3-64.6), a specificity of 81.8% (95% confidence interval, 47.8-96.8), a positive predictive value of 66.7% (95% confidence interval, 24.1-94.1), a negative predictive value of 52.9% (95% confidence interval, 28.5-76.1), a positive likelihood ratio of 1.83 (95% confidence interval, 0.41-8.11), and a negative likelihood ratio of 0.81 (95% confidence interval, 0.52-1.26). A vascular index ≥31 predicted the diagnosis of a severe morbidly adherent placenta with a 100% sensitivity (95% confidence interval, 72-100), a 90% specificity (95% confidence interval, 81.7-93.8), an 88% positive predictive value (95% confidence interval, 55.0-91.3), a 100% negative predictive value (95% confidence interval, 90.9-100), a positive likelihood ratio of 10.0 (95% confidence interval, 3.93-16.13), and a negative likelihood ratio of 0 (95% confidence interval, 0-0.34). Intrarater and interrater agreements were 94% (P < .001) and 93% (P < .001), respectively. The vascular index accurately predicts the morbidly adherent placenta in patients with placenta previa. In addition, 3-dimensional power Doppler vascular and vascular flow indices were more predictive of severe cases of morbidly adherent placenta compared with 2-dimensional ultrasound. This objective technique may limit the variations in diagnosing morbidly adherent placenta because of the subjectivity of 2-dimensional ultrasound interpretations. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The predictive value of MRI in detecting thyroid gland invasion in patients with advanced laryngeal or hypopharyngeal carcinoma.

    PubMed

    Lin, Peiliang; Huang, Xiaoming; Zheng, Chushan; Cai, Qian; Guan, Zhong; Liang, Faya; Zheng, Yiqing

    2017-01-01

    The aim of this study was to evaluate the predictive value of magnetic resonance imaging (MRI) in detecting thyroid gland invasion (TGI) in patients with advanced laryngeal or hypopharyngeal carcinoma. In a retrospective chart review, 41 patients with advanced laryngeal or hypopharyngeal carcinoma underwent MRI scan before total laryngectomy and ipsilateral or bilateral thyroidectomy during the past 5 years. The MRI findings were compared with the postoperative pathological results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Among the 41 patients, 3 had thyroid gland invasion in postoperative pathological results. MRI correctly predicted the absence of TGI in 37 of 38 patients and TGI in all 3 patients. The sensitivity, specificity, PPV, and NPV of MRI were 100.0, 97.4, 75.0, and 100 %, respectively, with the diagnostic accuracy of 97.6 %. In consideration of the high negative predictive value of MRI, it may help surgeons selectively preserve thyroid gland in total laryngectomy and reduce the incidence of hypothyroidism and hypoparathyroidism postoperatively.

  5. Psychological and socio-demographic data contributing to the resilience of holocaust survivors.

    PubMed

    Fossion, Pierre; Leys, Christophe; Kempenaers, Chantal; Braun, Stéphanie; Verbanck, Paul; Linkowski, Paul

    2014-01-01

    The authors provide a within-group study of 65 Former Hidden Children (FHC; i.e., Jewish youths who spent World War II in various hideaway shelters across Nazi-occupied Europe) evaluated by the Hopkins Symptom Check List (HSCL), the Sense of Coherence Scale (SOCS), the Resilience Scale for Adults (RSA), and a socio-demographic questionnaire. The aim of the present article is to address the sensitization model of resilience (consisting in a reduction of resistance to additional stress due to previous exposure to trauma) and to identify the family, psychological, and socio-demographic characteristics that predict resilience among a group of FHC. The RSA score is negatively correlated with the number of post-war traumas and positively correlated with the SOCS score. FHC who have children present a higher RSA score than FHC who have no children. RSA global score negatively and significantly predicts HSCL score. In a global multivariate model, and in accordance with the sensitization model, the number of post-war traumas negatively predicts the RSA score. Moreover, the SOCS score and the number of children positively predict it. Therapeutic implications are discussed, limitations are considered, and further investigations are proposed.

  6. Long-Term Associations of Justice Sensitivity, Rejection Sensitivity, and Depressive Symptoms in Children and Adolescents

    PubMed Central

    Bondü, Rebecca; Sahyazici-Knaak, Fidan; Esser, Günter

    2017-01-01

    Depressive symptoms have been related to anxious rejection sensitivity, but little is known about relations with angry rejection sensitivity and justice sensitivity. We measured rejection sensitivity, justice sensitivity, and depressive symptoms in 1,665 9-to-21-year olds at two points of measurement. Participants with high T1 levels of depressive symptoms reported higher anxious and angry rejection sensitivity and higher justice sensitivity than controls at T1 and T2. T1 rejection, but not justice sensitivity predicted T2 depressive symptoms; high victim justice sensitivity, however, added to the stabilization of depressive symptoms. T1 depressive symptoms positively predicted T2 anxious and angry rejection and victim justice sensitivity. Hence, sensitivity toward negative social cues may be cause and consequence of depressive symptoms and requires consideration in cognitive-behavioral treatment of depression. PMID:28955257

  7. Prediction of Toddlers’ Expressive Language From Maternal Sensitivity And Toddlers’ Anger Expressions: A Developmental Perspective

    PubMed Central

    Nozadi, Sara S; Spinrad, Tracy L; Eisenberg, Nancy; Bolnick, Rebecca; Eggum-Wilkens, Natalie. D; Smith, Cynthia L; Gaertner, Bridget; Kupfer, Anne; Sallquist, Julie

    2013-01-01

    Despite evidence for the importance of individual differences in expressive language during toddlerhood in predicting later literacy skills, few researchers have examined individual and contextual factors related to language abilities across the toddler years. Furthermore, a gap remains in the literature about the extent to which the relations of negative emotions and parenting to language skills may differ for girls and boys. The purpose of this longitudinal study was to investigate the associations among maternal sensitivity, children’s observed anger reactivity, and expressive language when children were 18 (T1; n = 247) and 30 (T2; n = 216) months. At each age, mothers reported on their toddlers’ expressive language, and mothers’ sensitive parenting behavior was observed during an unstructured free-play task. Toddlers’ anger expressions were observed during an emotion-eliciting task. Using path modeling, results showed few relations at T1. At T2, maternal sensitivity was negatively related to anger, and in turn, anger was associated with lower language skills. However, moderation analyses showed that these findings were significant for boys but not for girls. In addition, T1 maternal sensitivity and anger positively predicted expressive language longitudinally for both sexes. Findings suggest that the relations between maternal sensitivity, anger reactivity and expressive language may vary depending on the child’s developmental stage and sex. PMID:23911594

  8. The Predictive Validity of the ABFM's In-Training Examination.

    PubMed

    O'Neill, Thomas R; Li, Zijia; Peabody, Michael R; Lybarger, Melanie; Royal, Kenneth; Puffer, James C

    2015-05-01

    Our objective was to examine the predictive validity of the American Board of Family Medicine's (ABFM) In-Training Examination (ITE) with regard to predicting outcomes on the ABFM certification examination. This study used a repeated measures design across three levels of medical training (PGY1--PGY2, PGY2--PGY3, and PGY3--initial certification) with three different cohorts (2010--2011, 2011--2012, and 2012--2013) to examine: (1) how well the residents' ITE scores correlated with their test scores in the following year, (2) what the typical score increase was across training years, and (3) what was the sensitivity, specificity, positive predictive value, and negative predictive value of the PGY3 scores with regard to predicting future results on the MC-FP Examination. ITE scores generally correlate at about .7 with the following year's ITE or with the following year's certification examination. The mean growth from PGY1 to PGY2 was 52 points, from PGY2 to PGY3 was 34 points, and from PGY3 to initial certification was 27 points. The sensitivity, specificity, positive predictive value, and negative predictive value were .91, .47, .96, and .27, respectively. The ITE is a useful predictor of future ITE and initial certification examination performance.

  9. Evaluation of modified Alvarado scoring system and RIPASA scoring system as diagnostic tools of acute appendicitis.

    PubMed

    Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah

    2017-01-01

    Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (P<0.001) for both scoring systems. Based on the results of this study, the RIPASA score is a simple scoring system with better sensitivity and specificity than the modified Alvarado scoring system in Asian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado scoring system for Kuwait population.

  10. Office gel sonovaginography for the prediction of posterior deep infiltrating endometriosis: a multicenter prospective observational study.

    PubMed

    Reid, S; Lu, C; Hardy, N; Casikar, I; Reid, G; Cario, G; Chou, D; Almashat, D; Condous, G

    2014-12-01

    To use office gel sonovaginography (SVG) to predict posterior deep infiltrating endometriosis (DIE) in women undergoing laparoscopy. This was a multicenter prospective observational study carried out between January 2009 and February 2013. All women were of reproductive age, had a history of chronic pelvic pain and underwent office gel SVG assessment for the prediction of posterior compartment DIE prior to laparoscopic endometriosis surgery. Gel SVG findings were compared with laparoscopic findings to determine the diagnostic accuracy of office gel SVG for the prediction of posterior compartment DIE. In total, 189 women underwent preoperative gel SVG and laparoscopy for endometriosis. At laparoscopy, 57 (30%) women had posterior DIE and 43 (23%) had rectosigmoid/anterior rectal DIE. For the prediction of rectosigmoid/anterior rectal (i.e. bowel) DIE, gel SVG had an accuracy of 92%, sensitivity of 88%, specificity of 93%, positive predictive value (PPV) of 79%, negative predictive value (NPV) of 97%, positive likelihood ratio (LR+) of 12.9 and negative likelihood ratio (LR-) of 0.12 (P = 3.98E-25); for posterior vaginal wall and rectovaginal septum (RVS) DIE, respectively, the accuracy was 95% and 95%, sensitivity was 18% and 18%, specificity was 99% and 100%, PPV was 67% and 100%, NPV was 95% and 95%, LR+ was 32.4 and infinity and LR- was 0.82 and 0.82 (P = 0.009 and P = 0.003). Office gel SVG appears to be an effective outpatient imaging technique for the prediction of bowel DIE, with a higher accuracy for the prediction of rectosigmoid compared with anterior rectal DIE. Although the sensitivity for vaginal and RVS DIE was limited, gel SVG had a high specificity and NPV for all forms of posterior DIE, indicating that a negative gel SVG examination is highly suggestive of the absence of DIE at laparoscopy. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  11. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

    PubMed Central

    Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar

    2015-01-01

    Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055

  12. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    PubMed

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  13. Development and Validation of an Algorithm to Identify Planned Readmissions From Claims Data.

    PubMed

    Horwitz, Leora I; Grady, Jacqueline N; Cohen, Dorothy B; Lin, Zhenqiu; Volpe, Mark; Ngo, Chi K; Masica, Andrew L; Long, Theodore; Wang, Jessica; Keenan, Megan; Montague, Julia; Suter, Lisa G; Ross, Joseph S; Drye, Elizabeth E; Krumholz, Harlan M; Bernheim, Susannah M

    2015-10-01

    It is desirable not to include planned readmissions in readmission measures because they represent deliberate, scheduled care. To develop an algorithm to identify planned readmissions, describe its performance characteristics, and identify improvements. Consensus-driven algorithm development and chart review validation study at 7 acute-care hospitals in 2 health systems. For development, all discharges qualifying for the publicly reported hospital-wide readmission measure. For validation, all qualifying same-hospital readmissions that were characterized by the algorithm as planned, and a random sampling of same-hospital readmissions that were characterized as unplanned. We calculated weighted sensitivity and specificity, and positive and negative predictive values of the algorithm (version 2.1), compared to gold standard chart review. In consultation with 27 experts, we developed an algorithm that characterizes 7.8% of readmissions as planned. For validation we reviewed 634 readmissions. The weighted sensitivity of the algorithm was 45.1% overall, 50.9% in large teaching centers and 40.2% in smaller community hospitals. The weighted specificity was 95.9%, positive predictive value was 51.6%, and negative predictive value was 94.7%. We identified 4 minor changes to improve algorithm performance. The revised algorithm had a weighted sensitivity 49.8% (57.1% at large hospitals), weighted specificity 96.5%, positive predictive value 58.7%, and negative predictive value 94.5%. Positive predictive value was poor for the 2 most common potentially planned procedures: diagnostic cardiac catheterization (25%) and procedures involving cardiac devices (33%). An administrative claims-based algorithm to identify planned readmissions is feasible and can facilitate public reporting of primarily unplanned readmissions. © 2015 Society of Hospital Medicine.

  14. Detection of lipoarabinomannan as a diagnostic test for tuberculosis.

    PubMed Central

    Sada, E; Aguilar, D; Torres, M; Herrera, T

    1992-01-01

    A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favorable results were obtained for patients with AIDS and tuberculosis, with a sensitivity of 57%. The specificity in control patients with lung diseases different from tuberculosis and in healthy subjects was 100%. The positive predictive value was 100%, and the negative predictive value for patients with sputum-positive active pulmonary tuberculosis was 97%. The results of this study suggest that the detection of lipoarabinomannan is an accurate test for the diagnosis of pulmonary tuberculosis. PMID:1401008

  15. Prediction of venous wound healing with laser speckle imaging.

    PubMed

    van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha

    2017-12-01

    Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.

  16. Association between Gallbladder Ultrasound Findings and Bacterial Culture of Bile in 70 Cats and 202 Dogs.

    PubMed

    Policelli Smith, R; Gookin, J L; Smolski, W; Di Cicco, M F; Correa, M; Seiler, G S

    2017-09-01

    Bacterial cholecystitis often is diagnosed by combination of gallbladder ultrasound (US) findings and positive results of bile culture. The value of gallbladder US in determining the likelihood of bile bacterial infection in cats and dogs with suspected biliary disease is unknown. To determine the value of gallbladder US in predicting bile bacterial culture results, identify most common bacterial isolates from bile, and describe complications after cholecystocentesis in cats and dogs with suspected hepatobiliary disease. Cats (70) and dogs (202) that underwent an abdominal US and submission of bile for culture were included in the study. A cross-sectional study design was used to determine the association of gallbladder US abnormalities and the results of bile cultures, and complications of cholecystocentesis. Abnormal gallbladder US had high sensitivity (96%) but low specificity (49%) in cats with positive and negative results of bile bacterial culture, respectively. Cats with normal gallbladder US findings were unlikely to have positive bile bacterial culture (negative predictive value of 96%). Gallbladder US had lower sensitivity (81%), specificity (31%), positive predictive value (20%), and negative predictive value (88%) in dogs. The most common bacterial isolates were of enteric origin, the prevalence being higher in cats. Incidence of complications after cholecystocentesis was 3.4%. Gallbladder US has a high negative predictive value for bile culture results in cats. This modality is less predictive of infection in dogs. Percutaneous US-guided cholecystocentesis has a low complication rate. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Diagnostic accuracy of 3D-transvaginal ultrasound in detecting uterine cavity abnormalities in infertile patients as compared with hysteroscopy.

    PubMed

    Apirakviriya, Chayanis; Rungruxsirivorn, Tassawan; Phupong, Vorapong; Wisawasukmongchol, Wirach

    2016-05-01

    To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Patch testing and allergen-specific serum IgE and IgG antibodies in the diagnosis of canine adverse food reactions.

    PubMed

    Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S

    2012-02-15

    Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.

  19. Colonic polyps: application value of computer-aided detection in computed tomographic colonography.

    PubMed

    Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan

    2011-02-01

    Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.

  20. Thoracic computed tomography is an effective screening modality in patients with penetrating injuries to the chest.

    PubMed

    Strumwasser, Aaron; Chong, Vincent; Chu, Eveline; Victorino, Gregory P

    2016-09-01

    The precise role of thoracic CT in penetrating chest trauma remains to be defined. We hypothesized that thoracic CT effectively screens hemodynamically normal patients with penetrating thoracic trauma to surgery vs. expectant management (NOM). A ten-year review of all penetrating torso cases was retrospectively analyzed from our urban University-based trauma center. We included hemodynamically normal patients (systolic blood pressure ≥90) with penetrating chest injuries that underwent screening thoracic CT. Hemodynamically unstable patients and diaphragmatic injuries were excluded. The sensitivity, specificity, positive predictive value and negative predictive value were calculated. A total of 212 patients (mean injury severity score=24, Abbreviated Injury Score for Chest=3.9) met inclusion criteria. Of these, 84.3% underwent NOM, 9.1% necessitated abdominal exploration, 6.6% underwent exploration for retained hemothorax/empyema, 6.6% underwent immediate thoracic exploration for significant injuries on chest CT, and 1.0% underwent delayed thoracic exploration for missed injuries. Thoracic CT had a sensitivity of 82%, specificity of 99%, positive predictive value of 90%, a negative predictive value of 99%, and an accuracy of 99% in predicting surgery vs. NOM. Thoracic CT has a negative predictive value of 99% in triaging hemodynamically normal patients with penetrating chest trauma. Screening thoracic CT successfully excludes surgery in patients with non-significant radiologic findings. Copyright © 2016. Published by Elsevier Ltd.

  1. Interrelations among the adipocytokines leptin and adiponectin, oxidative stress and aseptic inflammation markers in pre- and early-pubertal normal-weight and obese boys.

    PubMed

    Paltoglou, George; Schoina, Maria; Valsamakis, George; Salakos, Nicolaos; Avloniti, Alexandra; Chatzinikolaou, Athanasios; Margeli, Alexandra; Skevaki, Chrysanthi; Papagianni, Maria; Kanaka-Gantenbein, Christina; Papassotiriou, Ioannis; Chrousos, George P; Fatouros, Ioannis G; Mastorakos, George

    2017-03-01

    Presumed interrelationships among deleterious aspects of adipose tissue metabolism, inflammation, and cellular oxidative stress could be influenced by pubertal hormonal changes. They were investigated in pre- and early pubertal normal-weight and obese boys before and after an exercise bout employed as an energy demanding stimulator. Cross-sectional study. Seventy-six healthy pre- (mean ± SD, 10.6 ± 0.2 years old, 28 normal-weight, and 11 obese) and early-(11.4 ± 0.2 years old, 25 normal-weight, and 12 obese) pubertal boys, were blood-sampled before and after a bout of exercise at 70% VO 2 max. Leptin, adiponectin, markers of inflammation (high-sensitivity C-reactive protein, high sensitivity IL-6), pro- (thiobarbitouric acid reactive substances, protein carbonyls) and anti- (glutathione, oxidized glutathione, glutathione peroxidase, catalase, total antioxidant capacity) oxidation were measured. Baseline and post-exercise adiponectin was greater and leptin and high-sensitivity C-reactive protein were lower in normal-weight than in obese pre- and early pubertal boys, while high sensitivity IL-6 was greater in obese than in normal-weight pre-pubertal boys. In pre-pubertal obese boys: at baseline, high-sensitivity C-reactive protein correlated negatively with catalase; high sensitivity IL-6 correlated positively with protein carbonyls; Δ (difference during exercise) adiponectin correlated positively with Δcatalase. In all boys: at baseline, high sensitivity IL-6 correlated positively with leptin and was the best negative and the second best positive predictor for post-exercise glutathione/oxidized glutathione and protein carbonyls, respectively; leptin was the best negative predictor for post-exercise glutathione; waist to height ratio was the best positive predictor for post-exercise thiobarbitouric acid reactive substances; body mass index z-score and adiponectin were, respectively, the best positive predictor for post-exercise protein carbonyls and catalase. In all subjects, leptin and adiponectin predict negatively and positively anti-oxidation, respectively, while high sensitivity IL-6 predicts positively and negatively pro- and anti-oxidation, respectively. High-sensitivity C-reactive protein is increased and negatively associated with anti-oxidation in pre-pubertal obese boys, suggesting that childhood obesity is associated with aseptic inflammation and oxidative stress.

  2. Comparison of three-view thoracic radiography and computed tomography for detection of pulmonary nodules in dogs with neoplasia.

    PubMed

    Armbrust, Laura J; Biller, David S; Bamford, Aubrey; Chun, Ruthanne; Garrett, Laura D; Sanderson, Michael W

    2012-05-01

    To compare the detection of pulmonary nodules by use of 3-view thoracic radiography and CT in dogs with confirmed neoplasia. Prospective case series. 33 dogs of various breeds. 3 interpreters independently evaluated 3-view thoracic radiography images. The location and size of pulmonary nodules were recorded. Computed tomographic scans of the thorax were obtained and evaluated by a single interpreter. The location, size, margin, internal architecture, and density of pulmonary nodules were recorded. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for thoracic radiography (with CT as the gold standard). 21 of 33 (64%) dogs had pulmonary nodules or masses detected on CT. Of the dogs that had positive CT findings, 17 of 21 (81%) had pulmonary nodules or masses detected on radiographs by at least 1 interpreter. Sensitivity of radiography ranged from 71% to 95%, and specificity ranged from 67% to 92%. Radiography had a positive predictive value of 83% to 94% and a negative predictive value of 65% to 89%. The 4 dogs that were negative for nodules on thoracic radiography but positive on CT were all large-breed to giant-breed dogs with osteosarcoma. CT was more sensitive than radiography for detection of pulmonary nodules. This was particularly evident in large-breed to giant-breed dogs. Thoracic CT is recommended in large-breed to giant-breed dogs with osteosarcoma if the detection of pulmonary nodules will change treatment.

  3. Accuracy of a Mouse Bioassay for the Diagnosis of Botulism in Horses.

    PubMed

    Johnson, A L; McAdams-Gallagher, S C; Aceto, H

    2016-07-01

    The laboratory diagnosis of botulism in horses traditionally has relied upon the mouse bioassay (MBA). The accuracy of this test for the diagnosis of botulism in horses is unknown. Our goal was to determine the sensitivity, specificity, positive predictive value, and negative predictive value of the MBA on laboratory-processed fecal and gastrointestinal samples for foals and adult horses. Cases included all horses with a final clinical diagnosis of botulism that were admitted between 1986 and 2011 and had MBA testing performed. Controls included horses without botulism that were admitted during the same time period and had MBA testing performed. Retrospective study. Horses suspected of having botulism had fecal or (less commonly) gastrointestinal content samples tested using MBA. For every hospitalized botulism suspect, control samples were obtained from ≥1 additional hospitalized horses not suspected to have botulism. One hundred and twenty-nine adult horses and 253 adult controls were identified. Overall sensitivity of the MBA was only 32% but specificity was 97%. Forty-three foal cases and 21 foal controls were evaluated; sensitivity of the MBA was 53% and specificity was 100%. Positive predictive value was substantially higher (100% for foals and 89% for adults) than negative predictive value (51% for foals and 67% for adults). Mouse bioassay has low sensitivity but high specificity for the diagnosis of botulism in horses. Positive results are highly suggestive of botulism but negative results do not exclude the diagnosis. Unaffected horses and foals rarely shed C. botulinum in their feces. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  4. Comparative study between cytotoxicity and flowcytometry crossmatches before and after renal transplantation.

    PubMed

    Abdel Rahman, Afaf S; Fahim, Nehal M A; El Sayed, Abeer A; El Hady, Soha A R; Ahmad, Yasser S

    2005-01-01

    Renal transplantation, in most countries, is based on human leukocyte antigen (HLA) matching of the donor kidney with the recipient. Traditional human leukocyte antigen matching is based on defining human leukocyte antigen specificities by antibodies utilizing cytotoxicity crossmatch techniques. Newer techniques have emerged, which challenge the accuracy of serological typing and crossmatching. We compared the results of the standard complement-dependent cytotoxicity crossmatch (CDCXM) with the anti-human globulin augmented cytotoxicity (AHG-CDC), and Flowcytometry crossmatch (FCXM) for the detection of anti-HLA antibodies in 150 pre-transplant patients. The development of post-transplantation sensitization was screened utilizing these three techniques within two weeks post-operative and correlated with rejection episodes. Comparison between the results of CDCXM and AHG-CDC in 150 recipients, revealed no significant correlation (P>0.05). When comparing these results with that of FCXM in 50 recipients a significant correlation was shown (P<0.05). Relative to CDCXM, the sensitivity of AHG-CDC was 100%, specificity 97.4%, positive predictive value 92.3%, and negative predictive value 100%. On the other hand, the sensitivity of FCXM was 100%, specificity 76.3%, positive predictive value 57.1%, and negative predictive value 100%. According to the results of CDCXM, AHG-CDC, and FCXM, no difference was detected between pre- and posttransplant anti-HLA sensitization within two weeks after the operation. Patients with negative cytotoxicity crossmatch (CDCXM and AHG-CDC) and positive FCXM may have an increased risk of early graft loss and may represent a relative contraindication to transplantation. Given the important theoretical advantages of FCXM over the CDC XM, further testing of the clinical relevance is warranted.

  5. [Validity and concordance of electronic health records in primary care (AP-Madrid) for surveillance of diabetes mellitus. PREDIMERC study].

    PubMed

    Gil Montalbán, Elisa; Ortiz Marrón, Honorato; López-Gay Lucio-Villegas, Dulce; Zorrilla Torrás, Belén; Arrieta Blanco, Francisco; Nogales Aguado, Pedro

    2014-01-01

    To assess the validity and concordance of diabetes data in the electronic health records of primary care (Madrid-PC) by comparing with those from the PREDIMERC study. The sensitivity, specificity, positive predictive value, negative predictive value and kappa index of diabetes cases recorded in the health records of Madrid-PC were calculated by using data from PREDIMERC as the gold standard. The prevalence of diabetes was also determined according to each data source. The sensitivity of diabetes recorded in Madrid-PC was 74%, the specificity was 98.8%, the positive predictive value was 87.9%, the negative predictive value was 97.3%, and the kappa index was 0.78. The prevalence of diabetes recorded in Madrid-PC was 6.7% versus 8.1% by PREDIMERC, where known diabetes was 6.3%. The electronic health records of primary care are a valid source for epidemiological surveillance of diabetes in Madrid. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.

  6. Insensitivity of the "Romberg test of standing balance on firm and compliant support surfaces" to the results of caloric and VEMP tests.

    PubMed

    Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren

    2011-01-01

    The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.

  7. 1.5-Tesla Multiparametric-Magnetic Resonance Imaging for the detection of clinically significant prostate cancer.

    PubMed

    Popita, Cristian; Popita, Anca Raluca; Sitar-Taut, Adela; Petrut, Bogdan; Fetica, Bogdan; Coman, Ioan

    2017-01-01

    Multiparametric-magnetic resonance imaging (mp-MRI) is the main imaging modality used for prostate cancer detection. The aim of this study is to evaluate the diagnostic performance of mp-MRI at 1.5-Tesla (1.5-T) for the detection of clinically significant prostate cancer. In this ethical board approved prospective study, 39 patients with suspected prostate cancer were included. Patients with a history of positive prostate biopsy and patients treated for prostate cancer were excluded. All patients were examined at 1.5-T MRI, before standard transrectal ultrasonography-guided biopsy. The overall sensitivity, specificity, positive predictive value and negative predictive value for mp-MRI were 100%, 73.68%, 80% and 100%, respectively. Our results showed that 1.5 T mp-MRI has a high sensitivity for detection of clinically significant prostate cancer and high negative predictive value in order to rule out significant disease.

  8. Two-question depression-screeners - the solution to all problems?

    PubMed

    Albani, Cornelia; Bailer, Harald; Blaser, Gerd; Brähler, Elmar; Geyer, Michael; Grulke, Norbert

    2006-04-01

    Depression constitutes a considerable issue in medicine and it is anticipated that the amount of people suffering from affective disorders will increase significantly. It would be useful to have a simple, fast screening procedure which would help detect depression. In four recently published articles a two-question depression-screener is recommended. Sensitivity, specificity, likelihood ratios, negative and positive predictive values were compared. For four different clinical samples and one sample that was representative of the German population the prevalence for depression ranged from 6.9 % to 18.1 %. Sensitivity and specificity reached values from 72.6 % to 96.6 % and from 56.9 % to 90.0 % respectively. All negative predictive values were high (< 97 %) opposed to positive predictive values (17.8 % to 38.5 %). Overall, it seems that the two-question screenings are well suited for the exclusion of a major depression. It is possible that regular screening could further lower the percentage of undiagnosed cases.

  9. Use of the International Classification of Diseases, 9th revision, coding in identifying chronic hepatitis B virus infection in health system data: implications for national surveillance.

    PubMed

    Mahajan, Reena; Moorman, Anne C; Liu, Stephen J; Rupp, Loralee; Klevens, R Monina

    2013-05-01

    With increasing use electronic health records (EHR) in the USA, we looked at the predictive values of the International Classification of Diseases, 9th revision (ICD-9) coding system for surveillance of chronic hepatitis B virus (HBV) infection. The chronic HBV cohort from the Chronic Hepatitis Cohort Study was created based on electronic health records (EHR) of adult patients who accessed services from 2006 to 2008 from four healthcare systems in the USA. Using the gold standard of abstractor review to confirm HBV cases, we calculated the sensitivity, specificity, positive and negative predictive values using one qualifying ICD-9 code versus using two qualifying ICD-9 codes separated by 6 months or greater. Of 1 652 055 adult patients, 2202 (0.1%) were confirmed as having chronic HBV. Use of one ICD-9 code had a sensitivity of 83.9%, positive predictive value of 61.0%, and specificity and negative predictive values greater than 99%. Use of two hepatitis B-specific ICD-9 codes resulted in a sensitivity of 58.4% and a positive predictive value of 89.9%. Use of one or two hepatitis B ICD-9 codes can identify cases with chronic HBV infection with varying sensitivity and positive predictive values. As the USA increases the use of EHR, surveillance using ICD-9 codes may be reliable to determine the burden of chronic HBV infection and would be useful to improve reporting by state and local health departments.

  10. Expressing negative emotions to children: Mothers' aversion sensitivity and children's adjustment.

    PubMed

    Moed, Anat; Dix, Theodore; Anderson, Edward R; Greene, Shannon M

    2017-03-01

    Research is unclear about when expressing negative emotions to children performs valuable socialization and regulatory functions and when, instead, it undermines children's adjustment. In this study, we isolated 1 kind of negative expression to test the aversion sensitivity hypothesis: that rapid increases in mothers' negativity as a function of increases in the aversiveness of children's behavior are uniquely problematic for children. During multiple assessments of a divorcing sample over 2 years (N = 284), 12-min interactions between mothers and their 4- to 11-year-old children were recorded. Forty-seven observed child behaviors were ranked from low to high aversive. Within-dyad changes demonstrated that mothers' general negativity-their tendency to express negative emotion at high rates-was unrelated to children's adjustment. In contrast, mothers' aversion-focused negativity-their tendency to increase negative emotional expression rapidly as the aversiveness of children's behavior increased-predicted children's poor social competence, poor emotion regulation, and externalizing behavior problems at the next assessment. The findings suggest that negative expression that reflects mothers' affective sensitivity to aversive child behavior may promote interaction patterns and adaptations in children that are particularly likely to place children at risk for adjustment problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Sensitivity and specificity of intrathecal fluorescein and white light excitation for detecting intraoperative cerebrospinal fluid leak in endoscopic skull base surgery: a prospective study.

    PubMed

    Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H

    2016-03-01

    The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.

  12. Use of the polymerase chain reaction to directly detect malaria parasites in blood samples from the Venezuelan Amazon.

    PubMed

    Laserson, K F; Petralanda, I; Hamlin, D M; Almera, R; Fuentes, M; Carrasquel, A; Barker, R H

    1994-02-01

    We have examined the reproducibility, sensitivity, and specificity of detecting Plasmodium falciparum using the polymerase chain reaction (PCR) and the species-specific probe pPF14 under field conditions in the Venezuelan Amazon. Up to eight samples were field collected from each of 48 consenting Amerindians presenting with symptoms of malaria. Sample processing and analysis was performed at the Centro Amazonico para la Investigacion y Control de Enfermedades Tropicales Simon Bolivar. A total of 229 samples from 48 patients were analyzed by PCR methods using four different P. falciparum-specific probes. One P. vivax-specific probe and by conventional microscopy. Samples in which results from PCR and microscopy differed were reanalyzed at a higher sensitivity by microscopy. Results suggest that microscopy-negative, PCR-positive samples are true positives, and that microscopy-positive and PCR-negative samples are true negatives. The sensitivity of the DNA probe/PCR method was 78% and its specificity was 97%. The positive predictive value of the PCR method was 88%, and the negative predictive value was 95%. Through the analysis of multiple blood samples from each individual, the DNA probe/PCR methodology was found to have an inherent reproducibility that was highly statistically significant.

  13. Ultrasound for Appendicitis: Performance and Integration with Clinical Parameters

    PubMed Central

    Löfvenberg, Fanny

    2016-01-01

    Objective. To evaluate the performance of ultrasound in pediatric appendicitis and the integration of US with the pediatric appendicitis score (PAS) and C-reactive protein (CRP). Method. An institution-based, retrospective study of children who underwent abdominal US for suspected appendicitis between 2012 and 2015 at a tertiary pediatric surgery center. US results were dichotomized, with a nonvisualized appendix considered as a negative examination. Results. In total, 438 children were included (mean 8.5 years, 54% boys), with an appendicitis rate of 29%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US were 82%, 97%, 92%, and 93%, respectively, without significant age or gender differences. Pediatric radiologists had significantly higher sensitivity compared to general radiologists, 88% and 71%, respectively (p < 0.01), but no differences were seen for specificity, PPV, and NPV. The sensitivity, NPV, and negative likelihood ratio for the combination of negative US, PAS < 5, and CRP < 5 mg/L were 98%, 98%, and 0.05 (95% CI 0.03–0.15). Conclusion. US may be a useful tool for evaluating children with suspected appendicitis, regardless of age or gender, and should be the first choice of imaging modalities. Combining US with PAS and CRP may reduce several unnecessary admissions for in-hospital observation. PMID:28044133

  14. Cost-effectiveness of digital subtraction angiography in the setting of computed tomographic angiography negative subarachnoid hemorrhage.

    PubMed

    Jethwa, Pinakin R; Punia, Vineet; Patel, Tapan D; Duffis, E Jesus; Gandhi, Chirag D; Prestigiacomo, Charles J

    2013-04-01

    Recent studies have documented the high sensitivity of computed tomography angiography (CTA) in detecting a ruptured aneurysm in the presence of acute subarachnoid hemorrhage (SAH). The practice of digital subtraction angiography (DSA) when CTA does not reveal an aneurysm has thus been called into question. We examined this dilemma from a cost-effectiveness perspective by using current decision analysis techniques. A decision tree was created with the use of TreeAge Pro Suite 2012; in 1 arm, a CTA-negative SAH was followed up with DSA; in the other arm, patients were observed without further imaging. Based on literature review, costs and utilities were assigned to each potential outcome. Base-case and sensitivity analyses were performed to determine the cost-effectiveness of each strategy. A Monte Carlo simulation was then conducted by sampling each variable over a plausible distribution to evaluate the robustness of the model. With the use of a negative predictive value of 95.7% for CTA, observation was found to be the most cost-effective strategy ($6737/Quality Adjusted Life Year [QALY] vs $8460/QALY) in the base-case analysis. One-way sensitivity analysis demonstrated that DSA became the more cost-effective option if the negative predictive value of CTA fell below 93.72%. The Monte Carlo simulation produced an incremental cost-effectiveness ratio of $83 083/QALY. At the conventional willingness-to-pay threshold of $50 000/QALY, observation was the more cost-effective strategy in 83.6% of simulations. The decision to perform a DSA in CTA-negative SAH depends strongly on the sensitivity of CTA, and therefore must be evaluated at each center treating these types of patients. Given the high sensitivity of CTA reported in the current literature, performing DSA on all patients with CTA negative SAH may not be cost-effective at every institution.

  15. Differences in sensitivity to parenting depending on child temperament: A meta-analysis.

    PubMed

    Slagt, Meike; Dubas, Judith Semon; Deković, Maja; van Aken, Marcel A G

    2016-10-01

    Several models of individual differences in environmental sensitivity postulate increased sensitivity of some individuals to either stressful (diathesis-stress), supportive (vantage sensitivity), or both environments (differential susceptibility). In this meta-analysis we examine whether children vary in sensitivity to parenting depending on their temperament, and if so, which model can best be used to describe this sensitivity pattern. We tested whether associations between negative parenting and negative or positive child adjustment as well as between positive parenting and positive or negative child adjustment would be stronger among children higher on putative sensitivity markers (difficult temperament, negative emotionality, surgency, and effortful control). Longitudinal studies with children up to 18 years (k = 105 samples from 84 studies, Nmean = 6,153) that reported on a parenting-by-temperament interaction predicting child adjustment were included. We found 235 independent effect sizes for associations between parenting and child adjustment. Results showed that children with a more difficult temperament (compared with those with a more easy temperament) were more vulnerable to negative parenting, but also profited more from positive parenting, supporting the differential susceptibility model. Differences in susceptibility were expressed in externalizing and internalizing problems and in social and cognitive competence. Support for differential susceptibility for negative emotionality was, however, only present when this trait was assessed during infancy. Surgency and effortful control did not consistently moderate associations between parenting and child adjustment, providing little support for differential susceptibility, diathesis-stress, or vantage sensitivity models. Finally, parenting-by-temperament interactions were more pronounced when parenting was assessed using observations compared to questionnaires. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. Predictive performance of the human Cell Line Activation Test (h-CLAT) for lipophilic chemicals with high octanol-water partition coefficients.

    PubMed

    Takenouchi, Osamu; Miyazawa, Masaaki; Saito, Kazutoshi; Ashikaga, Takao; Sakaguchi, Hitoshi

    2013-01-01

    To meet the urgent need for a reliable alternative test for predicting skin sensitizing potential of many chemicals, we have developed a cell-based in vitro test, human Cell Line Activation Test (h-CLAT). However, the predictive performance for lipophilic chemicals in the h-CLAT still remains relatively unknown. Moreover, it's suggested that low water solubility of chemicals might induce false negative outcomes. Thus, in this study, we tested relatively low water soluble 37 chemicals with log Kow values above and below 3.5 in the h-CLAT. The small-scale assessment resulted in nine false negative outcomes for chemicals with log Kow values greater than 3.5. We then created a dataset of 143 chemicals by combining the existing dataset of 106 chemicals and examined the predictive performance of the h-CLAT for chemicals with a log Kow of less than 3.5; a total of 112 chemicals from the 143 chemicals in the dataset. The sensitivity and overall accuracy for the 143 chemicals were 83% and 80%, respectively. In contrast, sensitivity and overall accuracy for the 112 chemicals with log Kow values below 3.5 improved to 94% and 88%, respectively. These data suggested that the h-CLAT could successfully detect sensitizers with log Kow values up to 3.5. When chemicals with log Kow values greater than 3.5 that were deemed positive by h-CLAT were included with the 112 chemicals, the sensitivity and accuracy in terms of the resulting applicable 128 chemicals out of the 143 chemicals became 95% and 88%, respectively. The use of log Kow values gave the h-CLAT a higher predictive performance. Our results demonstrated that the h-CLAT could predict sensitizing potential of various chemicals, which contain lipophilic chemicals using a large-scale chemical dataset.

  17. Sensitivity, Specificity, and Predictive Values of Pediatric Metabolic Syndrome Components in Relation to Adult Metabolic Syndrome: The Princeton LRC Follow-up Study

    PubMed Central

    Huang, Terry T-K; Nansel, Tonja R.; Belsheim, Allen R.; Morrison, John A.

    2008-01-01

    Objective To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoffs in relation to adult MetS. Study design Data from the NHLBI Lipid Research Clinics (LRC) Princeton Prevalence Study (1973–76) and the Princeton Follow-up Study (PFS, 2000-4) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff, as well as for aggregates of components. Results Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all five pediatric MetS components were considered, the presence of at least one abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Conclusions Considering multiple metabolic variables in childhood can improve the predictive utility for adult MetS, compared to each component or body mass alone. MetS variables may be useful for identifying some at risk children for prevention interventions. PMID:18206687

  18. Predictive value of painful popping for a posterior root tear of the medial meniscus in middle-aged to older Asian patients.

    PubMed

    Bae, Ji-Hoon; Paik, Nak Hwan; Park, Gyu-Won; Yoon, Jung-Ro; Chae, Dong-Ju; Kwon, Jae Ho; Kim, Jong In; Nha, Kyung-Wook

    2013-03-01

    The purpose of this study was to determine the accuracy, sensitivity, specificity, and predictive values of a single event of painful popping in the presence of a posterior root tear of the medial meniscus in middle-aged to older Asian patients. We conducted a retrospective review of medical records of 936 patients who underwent arthroscopic surgeries for an isolated medial meniscus tear between January 2000 and December 2010. There were 332 men and 604 women with a mean age of 41 years (range, 25 to 66 years). The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of a painful popping sensation for a posterior root tear of the medial meniscus were calculated. Arthroscopy confirmed the presence of posterior root tears of the medial menisci in 237 of 936 patients (25.3%). A single event of a painful popping sensation was present in 86 of these 936 patients (9.1%). Of these 86 patients with a painful popping sensation, 83 (96.5%) were categorized as having an isolated posterior root tear of the medial meniscus. The positive predictive value of a painful popping sensation in identifying a posterior root tear of the medial meniscus was 96.5%, the negative predictive value was 81.8%, the sensitivity was 35.0%, the specificity was 99.5%, and the diagnostic accuracy was 77.9%. A single event of painful popping can be a highly predictive clinical sign of a posterior root tear of the medial meniscus in the middle-aged to older Asian population. However, it has low sensitivity for the detection of a posterior root tear of the medial meniscus. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Consequences of ecological, evolutionary and biogeochemical uncertainty for coral reef responses to climatic stress.

    PubMed

    Mumby, Peter J; van Woesik, Robert

    2014-05-19

    Coral reefs are highly sensitive to the stress associated with greenhouse gas emissions, in particular ocean warming and acidification. While experiments show negative responses of most reef organisms to ocean warming, some autotrophs benefit from ocean acidification. Yet, we are uncertain of the response of coral reefs as systems. We begin by reviewing sources of uncertainty and complexity including the translation of physiological effects into demographic processes, indirect ecological interactions among species, the ability of coral reefs to modify their own chemistry, adaptation and trans-generational plasticity. We then incorporate these uncertainties into two simple qualitative models of a coral reef system under climate change. Some sources of uncertainty are far more problematic than others. Climate change is predicted to have an unambiguous negative effect on corals that is robust to several sources of uncertainty but sensitive to the degree of biogeochemical coupling between benthos and seawater. Macroalgal, zoanthid, and herbivorous fish populations are generally predicted to increase, but the ambiguity (confidence) of such predictions are sensitive to the source of uncertainty. For example, reversing the effect of climate-related stress on macroalgae from being positive to negative had no influence on system behaviour. By contrast, the system was highly sensitive to a change in the stress upon herbivorous fishes. Minor changes in competitive interactions had profound impacts on system behaviour, implying that the outcomes of mesocosm studies could be highly sensitive to the choice of taxa. We use our analysis to identify new hypotheses and suggest that the effects of climatic stress on coral reefs provide an exceptional opportunity to test emerging theories of ecological inheritance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. [Serum PTH levels as a predictive factor of hypocalcaemia after total thyroidectomy].

    PubMed

    Díez Alonso, Manuel; Sánchez López, José Daniel; Sánchez-Seco Peña, María Isabel; Ratia Jiménez, Tomás; Arribas Gómez, Ignacio; Rodríguez Pascual, Angel; Martín-Duce, Antonio; Guadalix Hidalgo, Gregorio; Hernández Domínguez, Sara; Granell Vicent, Javier

    2009-02-01

    Postoperative parathyroid hormone (PTH) levels as a predictor of hypocalcaemia in patients subjected to total thyroidectomy is analyzed. Prospective study involving 67 patients who underwent total thyroidectomy due to a benign disease. Serum PTH and ionised calcium were measured 20 h after surgery. Sensitivity, specificity and predictive values of PTH and ionised calcium levels were calculated to predict clinical and analytical hypocalcaemia. A total of 42 (62.7%) patients developed hypocalcaemia (ionised calcium<0.95 mmol/l), but only 20 (29.9%) presented with symptoms. PTH concentration the day after surgery was significantly lower in the group that developed symptomatic hypocalcaemia (5.57+/-6.4 pg/ml) than in the asymptomatic (21.5+/-15.3 pg/ml) or normocalcaemic (26.8+/-24.9 pg/ml) groups (p=0.001). Taking the value of 13 pg/ml as a cut-off point of PTH levels, sensitivity, specificity, positive predictive value and negative predictive value were 54%, 72%, 76% and 48%, respectively. On the other hand, sensitivity for predicting symptomatic hypocalcaemia was 95% and specificity was 76%. The test showed a high incidence of false positives (11/30, 36%). Negative predictive value was 97% and positive predictive value was 65%. In multivariate analysis, PTH and ionised calcium were the only perioperative factors that showed an independent predictive value as risk indicators of symptomatic hypocalcaemia. Normal PTH levels 20 h after surgery practically rule out the subsequent appearance of hypocalcaemia symptoms. On the other hand, low PTH levels are not necessarily associated to symptomatic hypocalcaemia due to the high number of false positives.

  1. Predicting HIV RNA virologic outcome at 52-weeks follow-up in antiretroviral clinical trials. The INCAS and AVANTI Study Groups.

    PubMed

    Raboud, J M; Rae, S; Montaner, J S

    2000-08-15

    To determine the ability of intermediate plasma viral load (pVL) measurements to predict virologic outcome at 52 weeks of follow-up in clinical trials of antiretroviral therapy. Individual patient data from three clinical trials (INCAS, AVANTI-2 and AVANTI-3) were combined into a single database. Virologic success was defined to be plasma viral load (pVL) <500 copies/ml at week 52. The sensitivity and specificity of intermediate pVL measurements below the limit of detection, 100, 500, 1000, and 5000 copies/ml to predict virologic success were calculated. The sensitivity, specificity, and positive and negative predictive values of a pVL measurement <1000 copies/ml at week 16 to predict virologic outcome at week 52 were 74%, 74%, 48%, and 90%, respectively, for patients on double therapy. For patients on triple therapy, the sensitivity, specificity, and positive and negative predictive values of a pVL measurement <50 copies/ml at week 16 to predict virologic outcome were 68%, 68%, 80%, and 47%, respectively. For patients receiving double therapy, a poor virologic result at an intermediate week of follow-up is a strong indicator of virologic failure at 52 weeks whereas intermediate virologic success is no guarantee of success at 1 year. For patients on triple therapy, disappointing intermediate results do not preclude virologic success at 1 year and intermediate successes are more likely to be sustained.

  2. The reliability, validity, sensitivity, specificity and predictive values of the Chinese version of the Rowland Universal Dementia Assessment Scale.

    PubMed

    Chen, Chia-Wei; Chu, Hsin; Tsai, Chia-Fen; Yang, Hui-Ling; Tsai, Jui-Chen; Chung, Min-Huey; Liao, Yuan-Mei; Chi, Mei-Ju; Chou, Kuei-Ru

    2015-11-01

    The purpose of this study was to translate the Rowland Universal Dementia Assessment Scale into Chinese and to evaluate the psychometric properties (reliability and validity) and the diagnostic properties (sensitivity, specificity and predictive values) of the Chinese version of the Rowland Universal Dementia Assessment Scale. The accurate detection of early dementia requires screening tools with favourable cross-cultural linguistic and appropriate sensitivity, specificity, and predictive values, particularly for Chinese-speaking populations. This was a cross-sectional, descriptive study. Overall, 130 participants suspected to have cognitive impairment were enrolled in the study. A test-retest for determining reliability was scheduled four weeks after the initial test. Content validity was determined by five experts, whereas construct validity was established by using contrasted group technique. The participants' clinical diagnoses were used as the standard in calculating the sensitivity, specificity, positive predictive value and negative predictive value. The study revealed that the Chinese version of the Rowland Universal Dementia Assessment Scale exhibited a test-retest reliability of 0.90, an internal consistency reliability of 0.71, an inter-rater reliability (kappa value) of 0.88 and a content validity index of 0.97. Both the patients and healthy contrast group exhibited significant differences in their cognitive ability. The optimal cut-off points for the Chinese version of the Rowland Universal Dementia Assessment Scale in the test for mild cognitive impairment and dementia were 24 and 22, respectively; moreover, for these two conditions, the sensitivities of the scale were 0.79 and 0.76, the specificities were 0.91 and 0.81, the areas under the curve were 0.85 and 0.78, the positive predictive values were 0.99 and 0.83 and the negative predictive values were 0.96 and 0.91 respectively. The Chinese version of the Rowland Universal Dementia Assessment Scale exhibited sound reliability, validity, sensitivity, specificity and predictive values. This scale can help clinical staff members to quickly and accurately diagnose cognitive impairment and provide appropriate treatment as early as possible. © 2015 John Wiley & Sons Ltd.

  3. Predicting posttraumatic stress disorder in children and parents following accidental child injury: evaluation of the Screening Tool for Early Predictors of Posttraumatic Stress Disorder (STEPP).

    PubMed

    van Meijel, Els P M; Gigengack, Maj R; Verlinden, Eva; Opmeer, Brent C; Heij, Hugo A; Goslings, J Carel; Bloemers, Frank W; Luitse, Jan S K; Boer, Frits; Grootenhuis, Martha A; Lindauer, Ramón J L

    2015-05-12

    Children and their parents are at risk of posttraumatic stress disorder (PTSD) following injury due to pediatric accidental trauma. Screening could help predict those at greatest risk and provide an opportunity for monitoring so that early intervention may be provided. The purpose of this study was to evaluate the Screening Tool for Early Predictors of Posttraumatic Stress Disorder (STEPP) in a mixed-trauma sample in a non-English speaking country (the Netherlands). Children aged 8-18 and one of their parents were recruited in two academic level I trauma centers. The STEPP was assessed in 161 children (mean age 13.9 years) and 156 parents within one week of the accident. Three months later, clinical diagnoses and symptoms of PTSD were assessed in 147 children and 135 parents. We used the Anxiety Disorders Interview Schedule for DSM-IV - Child and Parent version, the Children's Revised Impact of Event Scale and the Impact of Event Scale-Revised. Receiver Operating Characteristic analyses were performed to estimate the Areas Under the Curve as a measure of performance and to determine the optimal cut-off score in our sample. Sensitivity, specificity, positive and negative predictive values were calculated. The aim was to maximize both sensitivity and negative predictive values. PTSD was diagnosed in 12% of the children; 10% of their parents scored above the cut-off point for PTSD. At the originally recommended cut-off scores (4 for children, 3 for parents), the sensitivity in our sample was 41% for children and 54% for parents. Negative predictive values were 92% for both groups. Adjusting the cut-off scores to 2 improved sensitivity to 82% for children and 92% for parents, with negative predictive values of 92% and 96%, respectively. With adjusted cut-off scores, the STEPP performed well: 82% of the children and 92% of the parents with a subsequent positive diagnosis were identified correctly. Special attention in the screening procedure is required because of a high rate of false positives. The STEPP appears to be a valid and useful instrument that can be used in the Netherlands as a first screening method in stepped psychotrauma care following accidents.

  4. Meningitis in adult patients with a negative direct cerebrospinal fluid examination: value of cytochemical markers for differential diagnosis

    PubMed Central

    2011-01-01

    Introduction The objective of this study was to determine the ability of various parameters commonly used for the diagnosis of acute meningitis to differentiate between bacterial and viral meningitis, in adult patients with a negative direct cerebrospinal fluid (CSF) examination. Methods This was a prospective study, started in 1997, including all patients admitted to the emergency unit with acute meningitis and a negative direct CSF examination. Serum and CSF samples were taken immediately on admission. The patients were divided into two groups according to the type of meningitis: bacterial (BM; group I) or viral (VM; group II). The CSF parameters investigated were cytology, protein, glucose, and lactate; the serum parameters evaluated were C-reactive protein and procalcitonin. CSF/serum glucose and lactate ratios were also assessed. Results Of the 254 patients with meningitis with a negative direct CSF examination, 35 had BM and 181, VM. The most highly discriminative parameters for the differential diagnosis of BM proved to be CSF lactate, with a sensitivity of 94%, a specificity of 92%, a negative predictive value of 99%, a positive predictive value of 82% at a diagnostic cut-off level of 3.8 mmol/L (area under the curve (AUC), 0.96; 95% confidence interval (CI), 0.95 to 1), and serum procalcitonin, with a sensitivity of 95%, a specificity of 100%, a negative predictive value of 100%, and a positive predictive value of 97% at a diagnostic cut-off level of 0.28 ng/ml (AUC, 0.99; 95% CI, 0.99 to 1). Conclusions Serum procalcitonin and CSF lactate concentrations appear to be the most highly discriminative parameters for the differential diagnosis of BM and VM. PMID:21645387

  5. Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?

    PubMed

    Schaarschmidt, Benedikt Michael; Grueneisen, Johannes; Stebner, Vanessa; Klode, Joachim; Stoffels, Ingo; Umutlu, Lale; Schadendorf, Dirk; Heusch, Philipp; Antoch, Gerald; Pöppel, Thorsten Dirk

    2018-06-06

    To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.

  6. Accuracy of blood culture for early diagnosis of mediastinitis in febrile patients after cardiac surgery.

    PubMed

    San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J

    2005-03-01

    Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows: 73% sensitivity, 98% specificity, 90% positive predictive value, and 93% negative predictive value. Blood culture is an accurate test for the early diagnosis of PSM in febrile patients after cardiac surgery, particularly in institutions where S. aureus is prevalent in this context. A negative blood culture practically excludes PSM and, during the period of maximum risk for PSM, the presence of S. aureus bacteremia should compel early surgical management.

  7. Diagnostic accuracy of ultrasonography in detection of blunt abdominal trauma and comparison of early and late ultrasonography 24 hours after trauma.

    PubMed

    Feyzi, Ali; Rad, Masoud Pezeshki; Ahanchi, Navid; Firoozabadi, Jalil

    2015-01-01

    Despite the advantages of ultrasound scan, its use as a screening tool in blunt abdominal trauma is controversial. The aim of this study was to evaluate the diagnostic value of early and late ultrasound in patients with blunt abdominal trauma (BAT). In this study which was performed in a level I trauma center, firstly, 2418 patients with BAT had ultrasound (US) examination by two trauma expert radiologists. Results were compared with the best available gold standards such as laparotomy, CT, repeated ultrasound or clinical course follow-up. Then, 400 patients with BAT were examined by a trained residency student. In the first phase, sensitivity, specificity, negative predictive value, positive predictive value and accuracy of ultrasound were 97%, 98.1%, 99.7%, 83% and 98% respectively. In the second phase, they were 97.3%, 97.2%, 97.7%, 96.8% and 97.3% for the early and 98.5%, 97.6%, 98.5%, 97.5% and 98% for the late ultrasound respectively. Results obtained from this study indicate that negative ultrasound findings associated with negative clinical observation virtually exclude abdominal injury, and confirmation by performing other tests is unnecessary. High sensitivity and negative predictive value is achieved if ultrasound is performed by expert trauma radiologist.

  8. In vivo serial MRI-based models and statistical methods to quantify sensitivity and specificity of mechanical predictors for carotid plaque rupture: location and beyond.

    PubMed

    Wu, Zheyang; Yang, Chun; Tang, Dalin

    2011-06-01

    It has been hypothesized that mechanical risk factors may be used to predict future atherosclerotic plaque rupture. Truly predictive methods for plaque rupture and methods to identify the best predictor(s) from all the candidates are lacking in the literature. A novel combination of computational and statistical models based on serial magnetic resonance imaging (MRI) was introduced to quantify sensitivity and specificity of mechanical predictors to identify the best candidate for plaque rupture site prediction. Serial in vivo MRI data of carotid plaque from one patient was acquired with follow-up scan showing ulceration. 3D computational fluid-structure interaction (FSI) models using both baseline and follow-up data were constructed and plaque wall stress (PWS) and strain (PWSn) and flow maximum shear stress (FSS) were extracted from all 600 matched nodal points (100 points per matched slice, baseline matching follow-up) on the lumen surface for analysis. Each of the 600 points was marked "ulcer" or "nonulcer" using follow-up scan. Predictive statistical models for each of the seven combinations of PWS, PWSn, and FSS were trained using the follow-up data and applied to the baseline data to assess their sensitivity and specificity using the 600 data points for ulcer predictions. Sensitivity of prediction is defined as the proportion of the true positive outcomes that are predicted to be positive. Specificity of prediction is defined as the proportion of the true negative outcomes that are correctly predicted to be negative. Using probability 0.3 as a threshold to infer ulcer occurrence at the prediction stage, the combination of PWS and PWSn provided the best predictive accuracy with (sensitivity, specificity) = (0.97, 0.958). Sensitivity and specificity given by PWS, PWSn, and FSS individually were (0.788, 0.968), (0.515, 0.968), and (0.758, 0.928), respectively. The proposed computational-statistical process provides a novel method and a framework to assess the sensitivity and specificity of various risk indicators and offers the potential to identify the optimized predictor for plaque rupture using serial MRI with follow-up scan showing ulceration as the gold standard for method validation. While serial MRI data with actual rupture are hard to acquire, this single-case study suggests that combination of multiple predictors may provide potential improvement to existing plaque assessment schemes. With large-scale patient studies, this predictive modeling process may provide more solid ground for rupture predictor selection strategies and methods for image-based plaque vulnerability assessment.

  9. Test battery with the human cell line activation test, direct peptide reactivity assay and DEREK based on a 139 chemical data set for predicting skin sensitizing potential and potency of chemicals.

    PubMed

    Takenouchi, Osamu; Fukui, Shiho; Okamoto, Kenji; Kurotani, Satoru; Imai, Noriyasu; Fujishiro, Miyuki; Kyotani, Daiki; Kato, Yoshinao; Kasahara, Toshihiko; Fujita, Masaharu; Toyoda, Akemi; Sekiya, Daisuke; Watanabe, Shinichi; Seto, Hirokazu; Hirota, Morihiko; Ashikaga, Takao; Miyazawa, Masaaki

    2015-11-01

    To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  11. Accuracy of upper gastrointestinal swallow study in identifying strictures after laparoscopic gastric bypass surgery.

    PubMed

    Daylami, Rouzbeh; Rogers, Ann M; King, Tonya S; Haluck, Randy S; Shope, Timothy R

    2008-01-01

    Stricture at the gastrojejunal anastomosis after Roux-en-Y gastric bypass is a significant sequela that often requires intervention. The diagnosis of stricture is usually established by a recognized constellation of symptoms, followed by contrast radiography or endoscopy. The purpose of this report was to evaluate the accuracy of contrast swallow studies in excluding the diagnosis of gastrojejunal stricture. A retrospective analysis of the charts of 119 patients who had undergone laparoscopic Roux-en-Y gastric bypass, representing 41 upper gastrointestinal (GI) swallow studies, was conducted. Of those patients who underwent GI swallow studies, 30 then underwent definitive upper endoscopy to confirm or rule out stricture. The overall sensitivity, specificity, and negative predictive value of the swallow studies were calculated. Of the 30 patients who underwent upper endoscopic examination for symptoms of stricture after laparoscopic gastric bypass, 20 were confirmed to have a stricture. The sensitivity, specificity, and negative predictive value of the upper GI swallow study in this group was 55%, 100%, and 53%, respectively. The demographics of the patients with strictures were similar to those of the study group as a whole. The results of our study have shown that a positive upper GI swallow study is 100% specific for the presence of stricture. However, the sensitivity and negative predictive value of upper GI swallow studies were poor, making this modality unsatisfactory in definitively excluding the diagnosis of gastrojejunal stricture.

  12. [The role of endotracheal aspirate culture in the diagnosis of ventilator-associated pneumonia: a meta analysis].

    PubMed

    Wang, Fei; He, Bei

    2013-01-01

    To investigate the role of endotracheal aspirate (EA) culture in the diagnosis and antibiotic management in ventilator-associated pneumonia (VAP). We searched CNKI, Wanfang, PUBMED and EMBASE databases published from January 1990 to December 2011, to find relevant literatures on VAP microbiological diagnostic techniques including EA and bronchoalveolar lavage (BALF). The following key words were used: ventilator associated pneumonia, diagnosis and adult. Meta-analysis was performed and the sensitivity and specificity of EA on VAP diagnosis were calculated. Our literature search identified 1665 potential articles, 8 of which fulfilled our selection criteria including 561 patients with paired cultures. Using BALF quantitative culture as reference standard, the sensitivity and specificity of EA were 72% and 71%. When considering quantitative culture of EA only, the sensitivity and specificity improved to 90% and 65%, while the positive and the negative predictive values were 68% and 89% respectively. However, the sensitivity and specificity of semi-quantitative culture of EA were only 50% and 80%, with a positive predictive value of 77% and a negative predictive value of 58% respectively. EA culture had relatively poor sensitivity and specificity, although quantitative culture of EA only could improve the sensitivity. Initiating therapy on the basis of EA quantitative culture may still result in excessive antibiotic usage. Our data suggested that EA could provide some information for clinical decision but could not replace the role of BALF quantitative culture in VAP diagnosis.

  13. Evaluation of a new in-clinic test system to detect feline immunodeficiency virus and feline leukemia virus infection.

    PubMed

    Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin

    2010-06-01

    Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.

  14. Validity of Alcohol Use Disorder Identification Test-Korean Revised Version for Screening Alcohol Use Disorder according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition Criteria.

    PubMed

    Chang, Jung Wei; Kim, Jong Sung; Jung, Jin Gyu; Kim, Sung Soo; Yoon, Seok Joon; Jang, Hak Sun

    2016-11-01

    The Alcohol Use Disorder Identification Test (AUDIT) has been widely used to identify alcohol use disorder (AUD). This study evaluated the validity of the AUDIT-Korean revised version (AUDIT-KR) for screening AUD according to Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) criteria. This research was conducted with 443 subjects who visited the Chungnam National University Hospital for a comprehensive medical examination. All subjects completed the demographic questionnaire and AUDIT-KR without assistance. Subjects were divided into two groups according to DSM-5 criteria: an AUD group, which included patients that fit the criteria for AUD (120 males and 21 females), and a non-AUD group, which included 146 males and 156 females that did not meet AUD criteria. The appropriate cut-off values, sensitivity, specificity, and positive and negative predictive values of the AUDIT-KR were evaluated. The mean±standard deviation AUDIT-KR scores were 10.32±7.48 points in males and 3.23±4.42 points in females. The area under the receiver operating characteristic curve (95% confidence interval, CI) of the AUDIT-KR for identifying AUD was 0.884 (0.840-0.920) in males and 0.962 (0.923-0.985) in females. The optimal cut-off value of the AUDIT-KR was 10 points for males (sensitivity, 81.90%; specificity, 81.33%; positive predictive value, 77.2%; negative predictive value, 85.3%) and 5 points for females (sensitivity, 100.00%; specificity, 88.54%; positive predictive value, 52.6%; negative predictive value, 100.0%). The AUDIT-KR has high reliability and validity for identifying AUD according to DSM-5 criteria.

  15. Neural evidence for description dependent reward processing in the framing effect.

    PubMed

    Yu, Rongjun; Zhang, Ping

    2014-01-01

    Human decision making can be influenced by emotionally valenced contexts, known as the framing effect. We used event-related brain potentials to investigate how framing influences the encoding of reward. We found that the feedback related negativity (FRN), which indexes the "worse than expected" negative prediction error in the anterior cingulate cortex (ACC), was more negative for the negative frame than for the positive frame in the win domain. Consistent with previous findings that the FRN is not sensitive to "better than expected" positive prediction error, the FRN did not differentiate the positive and negative frame in the loss domain. Our results provide neural evidence that the description invariance principle which states that reward representation and decision making are not influenced by how options are presented is violated in the framing effect.

  16. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    PubMed

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  17. The amphetamine response moderates the relationship between negative emotionality and alcohol use.

    PubMed

    Allen, Kenneth J D; Gabbay, Frances H

    2013-02-01

    Considerable evidence suggests that sensitivity to the stimulant effects of alcohol and other drugs is a risk marker for heavy or problematic use of those substances. A separate body of research implicates negative emotionality. The goal of the present study was to evaluate the independent and interactive effects of the stimulant response, assessed with an amphetamine challenge, and negative emotionality on alcohol and drug use. Healthy young women and men completed the Multidimensional Personality Questionnaire (MPQ) and an inventory assessing alcohol and other drug use. Subsequently, the effects of 10-mg d-amphetamine were determined in the laboratory using the Stimulant scale of the Biphasic Alcohol Effects Scale. Hierarchical regression analyses evaluated the effects of amphetamine response and the MPQ factor Negative Emotionality on measures of substance use. The amphetamine response moderated relationships between negative emotionality and alcohol use: in combination with a robust amphetamine response (i.e., enhanced stimulant effects as compared with baseline), negative emotionality predicted greater alcohol consumption, more episodes of binge drinking, and more frequent intoxication in regression models. A strong stimulant response independently predicted having used an illicit drug, and there was a trend for it to predict having used alcohol. Negative emotionality alone was not associated with any measure of alcohol or drug use. Consistent with the idea that emotion-based behavioral dysregulation promotes reward seeking, a high level of negative emotionality was associated with maladaptive alcohol use when it co-occurred with sensitivity to drug-based reward. The findings contribute to our understanding of how differences in personality may interact with those in drug response to affect alcohol use. Copyright © 2012 by the Research Society on Alcoholism.

  18. The amphetamine response moderates the relationship between negative emotionality and alcohol use

    PubMed Central

    Allen, Kenneth J. D.; Gabbay, Frances H.

    2012-01-01

    Background Considerable evidence suggests that sensitivity to the stimulant effects of alcohol and other drugs is a risk marker for heavy or problematic use of those substances. A separate body of research implicates negative emotionality. The goal of the present study was to evaluate the independent and interactive effects of the stimulant response, assessed with an amphetamine challenge, and negative emotionality on alcohol and drug use. Methods Healthy young women and men completed the Multidimensional Personality Questionnaire (MPQ) and an inventory assessing alcohol and other drug use. Subsequently, the effects of 10 mg d-amphetamine were determined in the laboratory using the Stimulant scale of the Biphasic Alcohol Effects Scale. Hierarchical regression analyses evaluated the effects of amphetamine response and the MPQ factor Negative Emotionality on measures of substance use. Results The amphetamine response moderated relationships between negative emotionality and alcohol use: In combination with a robust amphetamine response (i.e., enhanced stimulant effects as compared to baseline), negative emotionality predicted greater alcohol consumption, more episodes of binge drinking, and more frequent intoxication in regression models. A strong stimulant response independently predicted having used an illicit drug, and there was a trend for it to predict having used alcohol. Negative emotionality alone was not associated with any measure of alcohol or drug use. Conclusions Consistent with the idea that emotion-based behavioral dysregulation promotes reward-seeking, a high level of negative emotionality was associated with maladaptive alcohol use when it co-occurred with sensitivity to drug-based reward. The findings contribute to our understanding of how differences in personality may interact with those in drug response to affect alcohol use. PMID:23240777

  19. Gram staining of protected pulmonary specimens in the early diagnosis of ventilator-associated pneumonia.

    PubMed

    Mimoz, O; Karim, A; Mazoit, J X; Edouard, A; Leprince, S; Nordmann, P

    2000-11-01

    We evaluated prospectively the use of Gram staining of protected pulmonary specimens to allow the early diagnosis of ventilator-associated pneumonia (VAP), compared with the use of 60 bronchoscopic protected specimen brushes (PSB) and 126 blinded plugged telescopic catheters (PTC) obtained from 134 patients. Gram stains were from Cytospin slides; they were studied for the presence of microorganisms in 10 and 50 fields by two independent observers and classified according to their Gram stain morphology. Quantitative cultures were performed after serial dilution and plating on appropriate culture medium. A final diagnosis of VAP, based on a culture of > or = 10(3) c.f.u. ml-1, was established after 81 (44%) samplings. When 10 fields were analysed, a strong relationship was found between the presence of bacteria on Gram staining and the final diagnosis of VAP (for PSB and PTC respectively: sensitivity 74 and 81%, specificity 94 and 100%, positive predictive value 91 and 100%, negative predictive value 82 and 88%). The correlation was less when we compared the morphology of microorganisms observed on Gram staining with those of bacteria obtained from quantitative cultures (for PSB and PTC respectively: sensitivity 54 and 69%, specificity 86 and 89%, positive predictive value 72 and 78%, negative predictive value 74 and 84%). Increasing the number of fields read to 50 was associated with a slight decrease in specificity and positive predictive value of Gram staining, but with a small increase in its sensitivity and negative predictive value. The results obtained by the two observers were similar to each other for both numbers of fields analysed. Gram staining of protected pulmonary specimens performed on 10 fields predicted the presence of VAP and partially identified (using Gram stain morphology) the microorganisms growing at significant concentrations, and could help in the early choice of the treatment of VAP. Increasing the number of fields read or having the Gram stain analysed by two independent individuals did not improve the results.

  20. Punishment sensitivity modulates the processing of negative feedback but not error-induced learning.

    PubMed

    Unger, Kerstin; Heintz, Sonja; Kray, Jutta

    2012-01-01

    Accumulating evidence suggests that individual differences in punishment and reward sensitivity are associated with functional alterations in neural systems underlying error and feedback processing. In particular, individuals highly sensitive to punishment have been found to be characterized by larger mediofrontal error signals as reflected in the error negativity/error-related negativity (Ne/ERN) and the feedback-related negativity (FRN). By contrast, reward sensitivity has been shown to relate to the error positivity (Pe). Given that Ne/ERN, FRN, and Pe have been functionally linked to flexible behavioral adaptation, the aim of the present research was to examine how these electrophysiological reflections of error and feedback processing vary as a function of punishment and reward sensitivity during reinforcement learning. We applied a probabilistic learning task that involved three different conditions of feedback validity (100%, 80%, and 50%). In contrast to prior studies using response competition tasks, we did not find reliable correlations between punishment sensitivity and the Ne/ERN. Instead, higher punishment sensitivity predicted larger FRN amplitudes, irrespective of feedback validity. Moreover, higher reward sensitivity was associated with a larger Pe. However, only reward sensitivity was related to better overall learning performance and higher post-error accuracy, whereas highly punishment sensitive participants showed impaired learning performance, suggesting that larger negative feedback-related error signals were not beneficial for learning or even reflected maladaptive information processing in these individuals. Thus, although our findings indicate that individual differences in reward and punishment sensitivity are related to electrophysiological correlates of error and feedback processing, we found less evidence for influences of these personality characteristics on the relation between performance monitoring and feedback-based learning.

  1. Better Learning with More Error: Probabilistic Feedback Increases Sensitivity to Correlated Cues in Categorization

    ERIC Educational Resources Information Center

    Little, Daniel R.; Lewandowsky, Stephan

    2009-01-01

    Despite the fact that categories are often composed of correlated features, the evidence that people detect and use these correlations during intentional category learning has been overwhelmingly negative to date. Nonetheless, on other categorization tasks, such as feature prediction, people show evidence of correlational sensitivity. A…

  2. ‎ Anxiety Sensitivity Dimensions and Generalized Anxiety‏ ‏Severity: The ‎Mediating Role of Experiential Avoidance and Repetitive‏ ‏Negative Thinking‎ ‎

    PubMed Central

    Mohammadkhani, Parvaneh; Pourshahbaz, Abbas; Kami, Maryam; Mazidi, Mahdi; Abasi, Imaneh‏

    2016-01-01

    Objective: Generalized anxiety disorder is one of the most common anxiety disorders in the general ‎population. Several studies suggest that anxiety sensitivity is a vulnerability factor in generalized ‎anxiety severity. However, some other studies suggest that negative repetitive thinking and ‎experiential avoidance as response factors can explain this relationship. Therefore, this study ‎aimed to investigate the mediating role of experiential avoidance and negative repetitive thinking ‎in the relationship between anxiety sensitivity and generalized anxiety severity.‎ Method: This was a cross-sectional and correlational study. A sample of 475 university students was ‎selected through stratified sampling method. The participants completed Anxiety Sensitivity ‎Inventory-3, Acceptance and Action Questionnaire-II, Perseverative Thinking Questionnaire, and ‎Generalized Anxiety Disorder 7-item Scale. Data were analyzed by Pearson correlation, multiple ‎regression analysis and path analysis.‎ Results: The results revealed a positive relationship between anxiety sensitivity, particularly cognitive ‎anxiety sensitivity, experiential avoidance, repetitive thinking and generalized anxiety severity. In ‎addition, findings showed that repetitive thinking, but not experiential avoidance, fully mediated ‎the relationship between cognitive anxiety sensitivity and generalized anxiety severity. α Level ‎was p<0.005.‎ Conclusion: Consistent with the trans-diagnostic hypothesis, anxiety sensitivity predicts generalized anxiety‏ ‏severity, but its effect is due to the generating repetitive negative thought.‎ PMID:27928245

  3. The role of model errors represented by nonlinear forcing singular vector tendency error in causing the "spring predictability barrier" within ENSO predictions

    NASA Astrophysics Data System (ADS)

    Duan, Wansuo; Zhao, Peng

    2017-04-01

    Within the Zebiak-Cane model, the nonlinear forcing singular vector (NFSV) approach is used to investigate the role of model errors in the "Spring Predictability Barrier" (SPB) phenomenon within ENSO predictions. NFSV-related errors have the largest negative effect on the uncertainties of El Niño predictions. NFSV errors can be classified into two types: the first is characterized by a zonal dipolar pattern of SST anomalies (SSTA), with the western poles centered in the equatorial central-western Pacific exhibiting positive anomalies and the eastern poles in the equatorial eastern Pacific exhibiting negative anomalies; and the second is characterized by a pattern almost opposite the first type. The first type of error tends to have the worst effects on El Niño growth-phase predictions, whereas the latter often yields the largest negative effects on decaying-phase predictions. The evolution of prediction errors caused by NFSV-related errors exhibits prominent seasonality, with the fastest error growth in the spring and/or summer seasons; hence, these errors result in a significant SPB related to El Niño events. The linear counterpart of NFSVs, the (linear) forcing singular vector (FSV), induces a less significant SPB because it contains smaller prediction errors. Random errors cannot generate a SPB for El Niño events. These results show that the occurrence of an SPB is related to the spatial patterns of tendency errors. The NFSV tendency errors cause the most significant SPB for El Niño events. In addition, NFSVs often concentrate these large value errors in a few areas within the equatorial eastern and central-western Pacific, which likely represent those areas sensitive to El Niño predictions associated with model errors. Meanwhile, these areas are also exactly consistent with the sensitive areas related to initial errors determined by previous studies. This implies that additional observations in the sensitive areas would not only improve the accuracy of the initial field but also promote the reduction of model errors to greatly improve ENSO forecasts.

  4. Magnetic resonance spectroscopy and brain volumetry in mild cognitive impairment. A prospective study.

    PubMed

    Fayed, Nicolás; Modrego, Pedro J; García-Martí, Gracián; Sanz-Requena, Roberto; Marti-Bonmatí, Luis

    2017-05-01

    To assess the accuracy of magnetic resonance spectroscopy (1H-MRS) and brain volumetry in mild cognitive impairment (MCI) to predict conversion to probable Alzheimer's disease (AD). Forty-eight patients fulfilling the criteria of amnestic MCI who underwent a conventional magnetic resonance imaging (MRI) followed by MRS, and T1-3D on 1.5 Tesla MR unit. At baseline the patients underwent neuropsychological examination. 1H-MRS of the brain was carried out by exploring the left medial occipital lobe and ventral posterior cingulated cortex (vPCC) using the LCModel software. A high resolution T1-3D sequence was acquired to carry out the volumetric measurement. A cortical and subcortical parcellation strategy was used to obtain the volumes of each area within the brain. The patients were followed up to detect conversion to probable AD. After a 3-year follow-up, 15 (31.2%) patients converted to AD. The myo-inositol in the occipital cortex and glutamate+glutamine (Glx) in the posterior cingulate cortex predicted conversion to probable AD at 46.1% sensitivity and 90.6% specificity. The positive predictive value was 66.7%, and the negative predictive value was 80.6%, with an overall cross-validated classification accuracy of 77.8%. The volume of the third ventricle, the total white matter and entorhinal cortex predict conversion to probable AD at 46.7% sensitivity and 90.9% specificity. The positive predictive value was 70%, and the negative predictive value was 78.9%, with an overall cross-validated classification accuracy of 77.1%. Combining volumetric measures in addition to the MRS measures the prediction to probable AD has a 38.5% sensitivity and 87.5% specificity, with a positive predictive value of 55.6%, a negative predictive value of 77.8% and an overall accuracy of 73.3%. Either MRS or brain volumetric measures are markers separately of cognitive decline and may serve as a noninvasive tool to monitor cognitive changes and progression to dementia in patients with amnestic MCI, but the results do not support the routine use in the clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Intracapsular implant rupture: MR findings of incomplete shell collapse.

    PubMed

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E

    1997-01-01

    The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.

  6. Individual differences in the impact of vicarious racism: African American students react to the George Zimmerman trial.

    PubMed

    Mason, Tyler B; Maduro, Ralitsa S; Derlega, Valerian J; Hacker, Desi S; Winstead, Barbara A; Haywood, Jacqueline E

    2017-04-01

    This research focused on how race-based rejection sensitivity (RS-Race) and components of racial identity intensify negative psychological reactions to an incident of vicarious racism. We examined how these individual difference variables directly and/or indirectly predicted African American students' reactions to the trial of George Zimmerman in the killing of the African American teenager, Trayvon Martin. In Study 1, 471 African American students completed measures of RS-Race, thought intrusions about the Zimmerman trial, and outcome variables (negative affect about the Zimmerman trial and forgiveness for Mr. Zimmerman). In Study 2, 304 African American students completed measures of racial identity (centrality, private regard, and public regard), thought intrusions about the Zimmerman trial, negative affect, and forgiveness. In Study 1, higher RS-Race was either directly and/or indirectly (via thought intrusions) related to more negative affect and lower forgiveness. In Study 2, high racial centrality and low public regard either directly and/or indirectly (via thought intrusions) predicted more negative affect and lower forgiveness. RS-Race and specific components of racial identity are likely to sensitize African Americans to incidents of racism that happen to other African Americans, leading to negative psychological reactions when these events occur. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  8. Usefulness of the volume-viscosity swallow test for screening dysphagia in subacute stroke patients in rehabilitation income.

    PubMed

    Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran

    2013-01-01

    Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.

  9. The effects of negative emotions on sensory perception: fear but not anger decreases tactile sensitivity.

    PubMed

    Kelley, Nicholas J; Schmeichel, Brandon J

    2014-01-01

    Emotions and sensory perceptions are closely intertwined. Of the five senses, sight has been by far the most extensively studied sense in emotion research. Relatively less is known about how emotions influence the other four senses. Touch is essential for nonverbal communication in both humans and other animals. The current investigation tested competing hypotheses about the effect of fear on tactile perception. One hypothesis based on evolutionary considerations predicts that fear enhances sensory perception, including tactile sensitivity. A competing hypothesis based on research on peripheral psychophysiology predicts that fear should decrease tactile sensitivity. Two experiments that induced negative emotional states and measured two-point discrimination ability at the fingertip found that fear reduces tactile sensitivity relative to anger or a neutral control condition (Studies 1 and 2). These findings did not appear to be driven by participants' naïve beliefs about the influence of emotions on touch (Study 3). The results represent the first evidence of the causal impact of emotional states on tactile sensitivity, are consistent with prior evidence for the peripheral physiological effects of fear, and offer novel empirical grounds for developing and advancing theories of emotional influences on sensory perception.

  10. The effects of negative emotions on sensory perception: fear but not anger decreases tactile sensitivity

    PubMed Central

    Kelley, Nicholas J.; Schmeichel, Brandon J.

    2014-01-01

    Emotions and sensory perceptions are closely intertwined. Of the five senses, sight has been by far the most extensively studied sense in emotion research. Relatively less is known about how emotions influence the other four senses. Touch is essential for nonverbal communication in both humans and other animals. The current investigation tested competing hypotheses about the effect of fear on tactile perception. One hypothesis based on evolutionary considerations predicts that fear enhances sensory perception, including tactile sensitivity. A competing hypothesis based on research on peripheral psychophysiology predicts that fear should decrease tactile sensitivity. Two experiments that induced negative emotional states and measured two-point discrimination ability at the fingertip found that fear reduces tactile sensitivity relative to anger or a neutral control condition (Studies 1 and 2). These findings did not appear to be driven by participants’ naïve beliefs about the influence of emotions on touch (Study 3). The results represent the first evidence of the causal impact of emotional states on tactile sensitivity, are consistent with prior evidence for the peripheral physiological effects of fear, and offer novel empirical grounds for developing and advancing theories of emotional influences on sensory perception. PMID:25202299

  11. Framing sound: Using expectations to reduce environmental noise annoyance.

    PubMed

    Crichton, Fiona; Dodd, George; Schmid, Gian; Petrie, Keith J

    2015-10-01

    Annoyance reactions to environmental noise, such as wind turbine sound, have public health implications given associations between annoyance and symptoms related to psychological distress. In the case of wind farms, factors contributing to noise annoyance have been theorised to include wind turbine sound characteristics, the noise sensitivity of residents, and contextual aspects, such as receiving information creating negative expectations about sound exposure. The experimental aim was to assess whether receiving positive or negative expectations about wind farm sound would differentially influence annoyance reactions during exposure to wind farm sound, and also influence associations between perceived noise sensitivity and noise annoyance. Sixty volunteers were randomly assigned to receive either negative or positive expectations about wind farm sound. Participants in the negative expectation group viewed a presentation which incorporated internet material indicating that exposure to wind turbine sound, particularly infrasound, might present a health risk. Positive expectation participants viewed a DVD which framed wind farm sound positively and included internet information about the health benefits of infrasound exposure. Participants were then simultaneously exposed to sub-audible infrasound and audible wind farm sound during two 7 min exposure sessions, during which they assessed their experience of annoyance. Positive expectation participants were significantly less annoyed than negative expectation participants, while noise sensitivity only predicted annoyance in the negative group. Findings suggest accessing negative information about sound is likely to trigger annoyance, particularly in noise sensitive people and, importantly, portraying sound positively may reduce annoyance reactions, even in noise sensitive individuals. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Breast cancer mammographic diagnosis performance in a public health institution: a retrospective cohort study.

    PubMed

    Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S

    2017-12-01

    To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.

  13. HPV-testing versus HPV-cytology co-testing to predict the outcome after conization.

    PubMed

    Bruhn, Laerke Valsøe; Andersen, Sisse Josephine; Hariri, Jalil

    2018-06-01

    The purpose of this study was to determine the feasibility of human Papillomavirus (HPV) testing alone as a prognostic tool to predict recurrent disease within a three-year follow-up period after treatment for cervical intraepithelial neoplasia (CIN)2 + . Retrospectively, 128 women with histologically verified CIN2 + who had a conization performed at Southern Jutland Hospital in Denmark between 1 January 2013 and 31 December 2013 were included. Histology, cytology and HPV test results were obtained for a three-year follow-up period. 4.7% (6/128) of the cases developed recurrent disease during follow-up. Of the cases without free margins, recurrent dysplasia was detected normal in 10.4% (5/48), whereas in the group with free margins it was 1.3% (1/80). The post-conization HPV test was negative in 67.2% (86/128) and Pap smear normal in 93.7% (120/128). Combining resection margins, cytology and HPV had sensitivity for prediction of recurrent dysplasia of 100%. Specificity was 45.8%, positive predictive value (PPV) 8.5% and negative predictive value (NPV) 100%. Using HPV test alone as a predictor of recurrent dysplasia gave a sensitivity of 83.3%, specificity 69.7%, PPV 11.9% and NPV 98.8%. Combining resection margin and HPV test had a sensitivity of 100%, specificity 45.9%, PPV 8.3% and NPV 100%. HPV test at six months control post-conization gave an NPV of 98.8% and can be used as a solitary test to identify women at risk for recurrent disease three years after treatment for precursor lesions. Using both resection margin and HPV test had a sensitivity of 100% and NPV 100%. Adding cytology did not increase the predictive value. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  14. Prospect theory does not describe the feedback-related negativity value function.

    PubMed

    Sambrook, Thomas D; Roser, Matthew; Goslin, Jeremy

    2012-12-01

    Humans handle uncertainty poorly. Prospect theory accounts for this with a value function in which possible losses are overweighted compared to possible gains, and the marginal utility of rewards decreases with size. fMRI studies have explored the neural basis of this value function. A separate body of research claims that prediction errors are calculated by midbrain dopamine neurons. We investigated whether the prospect theoretic effects shown in behavioral and fMRI studies were present in midbrain prediction error coding by using the feedback-related negativity, an ERP component believed to reflect midbrain prediction errors. Participants' stated satisfaction with outcomes followed prospect theory but their feedback-related negativity did not, instead showing no effect of marginal utility and greater sensitivity to potential gains than losses. Copyright © 2012 Society for Psychophysiological Research.

  15. Pancreatic fine needle aspiration. A comparison of computed tomographic and endoscopic ultrasonographic guidance.

    PubMed

    Qian, Xiaohua; Hecht, Jonathan L

    2003-01-01

    To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.

  16. A multiplex PCR assay for the rapid and sensitive detection of methicillin-resistant Staphylococcus aureus and simultaneous discrimination of Staphylococcus aureus from coagulase-negative staphylococci.

    PubMed

    Xu, Benjin; Liu, Ling; Liu, Li; Li, Xinping; Li, Xiaofang; Wang, Xin

    2012-11-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a global health concern, which had been detected in food and food production animals. Conventional testing for detection of MRSA takes 3 to 5 d to yield complete information of the organism and its antibiotic sensitivity pattern. So, a rapid method is needed to diagnose and treat the MRSA infections. The present study focused on the development of a multiplex PCR assay for the rapid and sensitive detection of MRSA. The assay simultaneously detected 4 genes, namely, 16S rRNA of the Staphylococcus genus, femA of S. aureus, mecA that encodes methicillin resistance, and one internal control. It was rapid and yielded results within 4 h. The analytical sensitivity and specificity of the multiplex PCR assay was evaluated by comparing it with the conventional method. The analytical sensitivity of the multiplex PCR assay at the DNA level was 10 ng DNA. The analytical specificity was evaluated with 10 reference staphylococci strains and was 100%. The diagnostic evaluation of MRSA was carried out using 360 foodborne staphylococci isolates, and showed 99.1% of specificity, 96.4% of sensitivity, 97.5% of positive predictive value, and 97.3% of negative predictive value compared to the conventional method. The inclusion of an internal control in the multiplex PCR assay is important to exclude false-negative cases. This test can be used as an effective diagnostic and surveillance tool to investigate the spread and emergence of MRSA. © 2012 Institute of Food Technologists®

  17. Diagnostic accuracy and reproducibility of pleural and lung ultrasound in discriminating cardiogenic causes of acute dyspnea in the emergency department.

    PubMed

    Cibinel, Gian Alfonso; Casoli, Giovanna; Elia, Fabrizio; Padoan, Monica; Pivetta, Emanuele; Lupia, Enrico; Goffi, Alberto

    2012-02-01

    Dyspnea is a common symptom in patients admitted to the Emergency Department (ED), and discriminating between cardiogenic and non-cardiogenic dyspnea is often a clinical dilemma. The initial diagnostic work-up may be inaccurate in defining the etiology and the underlying pathophysiology. The aim of this study was to evaluate the diagnostic accuracy and reproducibility of pleural and lung ultrasound (PLUS), performed by emergency physicians at the time of a patient's initial evaluation in the ED, in identifying cardiac causes of acute dyspnea. Between February and July 2007, 56 patients presenting to the ED with acute dyspnea were prospectively enrolled in this study. In all patients, PLUS was performed by emergency physicians with the purpose of identifying the presence of diffuse alveolar-interstitial syndrome (AIS) or pleural effusion. All scans were later reviewed by two other emergency physicians, expert in PLUS and blinded to clinical parameters, who were the ultimate judges of positivity for diffuse AIS and pleural effusion. A random set of 80 recorded scannings were also reviewed by two inexperienced observers to assess inter-observer variability. The entire medical record was independently reviewed by two expert physicians (an emergency medicine physician and a cardiologist) blinded to the ultrasound (US) results, in order to determine whether, for each patient, dyspnea was due to heart failure, or not. Sensitivity, specificity, and positive/negative predictive values were obtained; likelihood ratio (LR) test was used. Cohen's kappa was used to assess inter-observer agreement. The presence of diffuse AIS was highly predictive for cardiogenic dyspnea (sensitivity 93.6%, specificity 84%, positive predictive value 87.9%, negative predictive value 91.3%). On the contrary, US detection of pleural effusion was not helpful in the differential diagnosis (sensitivity 83.9%, specificity 52%, positive predictive value 68.4%, negative predictive value 72.2%). Finally, the coexistence of diffuse AIS and pleural effusion is less accurate than diffuse AIS alone for cardiogenic dyspnea (sensitivity 81.5%, specificity 82.8%, positive predictive value 81.5%, negative predictive value 82.8%). The positive LR was 5.8 for AIS [95% confidence interval (CI) 4.8-7.1] and 1.7 (95% CI 1.2-2.6) for pleural effusion, negative LR resulted 0.1 (95% CI 0.0-0.4) for AIS and 0.3 (95% CI 0.1-0.8) for pleural effusion. Agreement between experienced and inexperienced operators was 92.2% (p < 0.01) and 95% (p < 0.01) for diagnosis of AIS and pleural effusion, respectively. In early evaluation of patients presenting to the ED with dyspnea, PLUS, performed with the purpose of identifying diffuse AIS, may represent an accurate and reproducible bedside tool in discriminating between cardiogenic and non-cardiogenic dyspnea. On the contrary, US detection of pleural effusions does not allow reliable discrimination between different causes of acute dyspnea in unselected ED patients.

  18. Toddler Emotional States, Temperamental Traits, and Their Interaction: Associations with Mothers’ and Fathers’ Parenting

    PubMed Central

    Fields, Margaret A.; Cole, Pamela M.; Maggi, Mirella C.

    2016-01-01

    We investigated the degree to which toddlers’ observed emotional states, toddlers’ temperamental traits, and their interaction accounted for variance in mothers’ and fathers’ parenting. Main effects of two emotional states (positive emotion and negative emotion), three temperamental traits (negative affectivity, effortful control, and surgency) as well as state-by-trait interactions, were examined in relation to parental sensitivity, positive affect, and negative affect. The hypothesis that toddlers’ temperamental traits would moderate the association between their observed emotional states and parenting was partially supported. Significant state-by-trait interactions were found in models predicting the probability that mothers and fathers expressed negative affect towards their toddlers. For parental sensitivity and positive affect, only main effects of temperament and/or emotion expression accounted for variance in parenting. PMID:28479643

  19. Accuracy of Self-Reported Cervical and Breast Cancer Screening by Women with Intellectual Disability

    ERIC Educational Resources Information Center

    Son, Esther; Parish, Susan L.; Swaine, Jamie G.; Luken, Karen

    2013-01-01

    This study examines the accuracy of self-report of cervical and breast cancer screening by women with intellectual disability ("n" ?=? 155). Data from face-to-face interviews and medical records were analyzed. Total agreement, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Total…

  20. Exposure-based screening for Nipah virus encephalitis, Bangladesh.

    PubMed

    Sazzad, Hossain M S; Luby, Stephen P; Ströher, Ute; Daszak, Peter; Sultana, Sharmin; Afroj, Sayma; Rahman, Mahmudur; Gurley, Emily S

    2015-02-01

    We measured the performance of exposure screening questions to identify Nipah virus encephalitis in hospitalized encephalitis patients during the 2012-13 Nipah virus season in Bangladesh. The sensitivity (93%), specificity (82%), positive predictive value (37%), and negative predictive value (99%) results suggested that screening questions could more quickly identify persons with Nipah virus encephalitis.

  1. Familial Breast/Ovarian Cancer and BRCA1/2 Genetic Screening: The Role of Immunohistochemistry as an Additional Method in the Selection of Patients

    PubMed Central

    Vaz, Fátima H.; Machado, Patrícia M.; Brandão, Rita D.; Laranjeira, Cátia T.; Eugénio, Joana S.; Fernandes, Aires H.; André, Saudade P.

    2007-01-01

    Only 20–25% of families screened for BRCA1/2 mutations are found positive. Because only a positive result is informative, we studied the role of BRCA1/2 immunohistochemistry as an additional method for patient selection. From 53 high-risk-affected probands, 18 (34%) had available paraffin blocks of their tumors and were selected for this study. Mutation screening was done by conformation-sensitive gel electrophoresis and multiplex ligation-dependent probe amplification. For immunohistochemistry, 21 neoplastic specimens (15 breast carcinomas, 5 ovary neoplasms, and 1 rectal adenocarcinoma) were analyzed with BRCA1 (monoclonal antibody, Ab-1, oncogene) and BRCA2 (polyclonal antibody, Ab-2, oncogene) antibodies. Absence of the BRCA1 protein was confirmed in negative tumors by Western blotting. Seven patients were positive for BRCA1/2 mutations: 5 for BRCA1 and 2 for BRCA2. Four out of five positive patients had tumors negative for BRCA1 immunostaining, and the remaining 13 BRCA1-negative patients had positive BRCA1 immunostaining in all tumor samples. Sensitivity to predict for BRCA1 mutation carriers was 80%, and specificity was 100%, with a positive predictive value of 100% and a negative predictive value of 93%. This correlation was statistically significant (p=0.001). No correlation was observed for BRCA2. If larger studies confirm these results, high-risk patients with BRCA1-negative tumors should be screened first for this gene. PMID:17625228

  2. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  3. Assessing Breast Cancer Risk with an Artificial Neural Network

    PubMed

    Sepandi, Mojtaba; Taghdir, Maryam; Rezaianzadeh, Abbas; Rahimikazerooni, Salar

    2018-04-25

    Objectives: Radiologists face uncertainty in making decisions based on their judgment of breast cancer risk. Artificial intelligence and machine learning techniques have been widely applied in detection/recognition of cancer. This study aimed to establish a model to aid radiologists in breast cancer risk estimation. This incorporated imaging methods and fine needle aspiration biopsy (FNAB) for cyto-pathological diagnosis. Methods: An artificial neural network (ANN) technique was used on a retrospectively collected dataset including mammographic results, risk factors, and clinical findings to accurately predict the probability of breast cancer in individual patients. Area under the receiver-operating characteristic curve (AUC), accuracy, sensitivity, specificity, and positive and negative predictive values were used to evaluate discriminative performance. Result: The network incorporating the selected features performed best (AUC = 0.955). Sensitivity and specificity of the ANN were respectively calculated as 0.82 and 0.90. In addition, negative and positive predictive values were respectively computed as 0.90 and 0.80. Conclusion: ANN has potential applications as a decision-support tool to help underperforming practitioners to improve the positive predictive value of biopsy recommendations. Creative Commons Attribution License

  4. Analysis of the utility of stone gram stain in urolithiasis treated with percutaneous nephrolithotomy.

    PubMed

    Cockerill, Patrick A; Rivera, Marcelino E; Krambeck, Amy E

    2014-06-01

    To define the sensitivity and specificity of stone gram stain for infected urolithiasis treated with percutaneous nephrolithotomy (PCNL). PCNL procedures performed at our institution were analyzed between January 2009 and May 2013. Stone fragments were sent in a sterile fashion for aerobic and fungal cultures. A gram stain and fungal smear were performed on the stones and reported within 24 hours of collection. A total of 228 patients underwent 248 PCNLs. Of the 248 stones, 81 (33%) had a positive stone culture. Stone gram stain was positive in 31 cases and negative in 50. There were 167 negative stone cultures, and in these cases, gram stain was positive in 5 and negative in 162. The calculated sensitivity and specificity of stone gram stain were 38% and 97%. The positive and negative predictive values were 86% and 76%, respectively. In the subset of 16 patients with positive stone fungal cultures, fungal smear was performed in 12 and was positive in 4, giving fungal smear a sensitivity of 33%. The results of this study suggest that stone gram stain cannot be relied on to detect a positive stone culture and may fail to detect up to 62% of infected stones. However, when positive, gram stain accurately predicts a positive stone culture in 86% of cases. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Self-diagnosis of active head lice infestation by individuals from an impoverished community: high sensitivity and specificity.

    PubMed

    Pilger, Daniel; Khakban, Adak; Heukelbach, Jorg; Feldmeier, Hermann

    2008-01-01

    To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

  6. Neural evidence for description dependent reward processing in the framing effect

    PubMed Central

    Yu, Rongjun; Zhang, Ping

    2014-01-01

    Human decision making can be influenced by emotionally valenced contexts, known as the framing effect. We used event-related brain potentials to investigate how framing influences the encoding of reward. We found that the feedback related negativity (FRN), which indexes the “worse than expected” negative prediction error in the anterior cingulate cortex (ACC), was more negative for the negative frame than for the positive frame in the win domain. Consistent with previous findings that the FRN is not sensitive to “better than expected” positive prediction error, the FRN did not differentiate the positive and negative frame in the loss domain. Our results provide neural evidence that the description invariance principle which states that reward representation and decision making are not influenced by how options are presented is violated in the framing effect. PMID:24733998

  7. 1.5-Tesla Multiparametric-Magnetic Resonance Imaging for the detection of clinically significant prostate cancer

    PubMed Central

    POPITA, CRISTIAN; POPITA, ANCA RALUCA; SITAR-TAUT, ADELA; PETRUT, BOGDAN; FETICA, BOGDAN; COMAN, IOAN

    2017-01-01

    Background and aim Multiparametric-magnetic resonance imaging (mp-MRI) is the main imaging modality used for prostate cancer detection. The aim of this study is to evaluate the diagnostic performance of mp-MRI at 1.5-Tesla (1.5-T) for the detection of clinically significant prostate cancer. Methods In this ethical board approved prospective study, 39 patients with suspected prostate cancer were included. Patients with a history of positive prostate biopsy and patients treated for prostate cancer were excluded. All patients were examined at 1.5-T MRI, before standard transrectal ultrasonography–guided biopsy. Results The overall sensitivity, specificity, positive predictive value and negative predictive value for mp-MRI were 100%, 73.68%, 80% and 100%, respectively. Conclusion Our results showed that 1.5 T mp-MRI has a high sensitivity for detection of clinically significant prostate cancer and high negative predictive value in order to rule out significant disease. PMID:28246496

  8. Validation of the 4P's Plus screen for substance use in pregnancy validation of the 4P's Plus.

    PubMed

    Chasnoff, I J; Wells, A M; McGourty, R F; Bailey, L K

    2007-12-01

    The purpose of this study is to validate the 4P's Plus screen for substance use in pregnancy. A total of 228 pregnant women enrolled in prenatal care underwent screening with the 4P's Plus and received a follow-up clinical assessment for substance use. Statistical analyses regarding reliability, sensitivity, specificity, and positive and negative predictive validity of the 4Ps Plus were conducted. The overall reliability for the five-item measure was 0.62. Seventy-four (32.5%) of the women had a positive screen. Sensitivity and specificity were very good, at 87 and 76%, respectively. Positive predictive validity was low (36%), but negative predictive validity was quite high (97%). Of the 31 women who had a positive clinical assessment, 45% were using less than 1 day per week. The 4P's Plus reliably and effectively screens pregnant women for risk of substance use, including those women typically missed by other perinatal screening methodologies.

  9. Rapid MRSA PCR on respiratory specimens from ventilated patients with suspected pneumonia: a tool to facilitate antimicrobial stewardship.

    PubMed

    Trevino, S E; Pence, M A; Marschall, J; Kollef, M H; Babcock, H M; Burnham, C-A D

    2017-05-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is an important cause of pneumonia in ventilated patients. Our objective was to evaluate the GeneXpert MRSA/SA SSTI Assay (Xpert MRSA/SA) (Cepheid, Sunnyvale, CA) for use in lower respiratory tract (LRT) specimens for rapid MRSA detection and to determine the potentially saved antibiotic-days if a culture-based identification method was replaced by this assay. Remnant LRT samples from ventilated patients submitted to the microbiology laboratory for routine culture were tested using conventional culture and Xpert MRSA/SA. One hundred of 310 LRT specimens met the inclusion criteria. Ten samples were positive for MRSA by Xpert MRSA/SA, while six were positive by routine culture methods. Xpert MRSA/SA correctly identified 5/6 positive and 89/94 negative MRSA specimens, for a sensitivity of 83.3%, specificity of 94.7%, positive predictive value of 45.6%, and negative predictive value of 98.9%. The assay also correctly detected 3/3 positive and 90/97 negative methicillin-susceptible S. aureus (MSSA) specimens, for a sensitivity of 100%, specificity of 92.8%, positive predictive value of 30%, and negative predictive value of 100%. A total of 748 vancomycin and 305 linezolid antibiotic-days were associated with the enrolled specimens. Vancomycin and linezolid utilization could decrease by 68.4% and 83%, respectively, if discontinued 1 day after negative polymerase chain reaction (PCR) results. The Xpert MRSA/SA SSTI rapid MRSA PCR assay performed well in respiratory samples from ventilated patients with suspected pneumonia and has the potential to facilitate stewardship efforts such as reducing empiric vancomycin and linezolid therapy.

  10. Determinants of Prosocial Behavior in Included Versus Excluded Contexts

    PubMed Central

    Cuadrado, Esther; Tabernero, Carmen; Steinel, Wolfgang

    2016-01-01

    Prosocial behavior (PSB) is increasingly becoming necessary as more and more individuals experience exclusion. In this context it is important to understand the motivational determinants of PSB. Here we report two experiments which analyzed the influence of dispositional (prosocialness; rejection sensitivity) and motivational variables (prosocial self-efficacy; prosocial collective efficacy; trust; anger; social affiliation motivation) on PSB under neutral contexts (Study 1), and once under inclusion or exclusion conditions (Study 2). Both studies provided evidence for the predicted mediation of PSB. Results in both neutral and inclusion and exclusion conditions supported our predictive model of PSB. In the model dispositional variables predicted motivational variables, which in turn predicted PSB. We showed that the investigated variables predicted PSB; this suggests that to promote PSB one could (1) foster prosocialness, prosocial self and collective efficacy, trust in others and affiliation motivation and (2) try to reduce negative feelings and the tendency to dread rejection in an attempt to reduce the negative impact that these variables have on PSB. Moreover, the few differences that emerged in the model between the inclusion and exclusion contexts suggested that in interventions with excluded individuals special care emphasis should be placed on addressing rejection sensitivity and lack of trust. PMID:26779103

  11. Determinants of Prosocial Behavior in Included Versus Excluded Contexts.

    PubMed

    Cuadrado, Esther; Tabernero, Carmen; Steinel, Wolfgang

    2015-01-01

    Prosocial behavior (PSB) is increasingly becoming necessary as more and more individuals experience exclusion. In this context it is important to understand the motivational determinants of PSB. Here we report two experiments which analyzed the influence of dispositional (prosocialness; rejection sensitivity) and motivational variables (prosocial self-efficacy; prosocial collective efficacy; trust; anger; social affiliation motivation) on PSB under neutral contexts (Study 1), and once under inclusion or exclusion conditions (Study 2). Both studies provided evidence for the predicted mediation of PSB. Results in both neutral and inclusion and exclusion conditions supported our predictive model of PSB. In the model dispositional variables predicted motivational variables, which in turn predicted PSB. We showed that the investigated variables predicted PSB; this suggests that to promote PSB one could (1) foster prosocialness, prosocial self and collective efficacy, trust in others and affiliation motivation and (2) try to reduce negative feelings and the tendency to dread rejection in an attempt to reduce the negative impact that these variables have on PSB. Moreover, the few differences that emerged in the model between the inclusion and exclusion contexts suggested that in interventions with excluded individuals special care emphasis should be placed on addressing rejection sensitivity and lack of trust.

  12. Cytomegalovirus frequency in neonatal intrahepatic cholestasis determined by serology, histology, immunohistochemistry and PCR

    PubMed Central

    Bellomo-Brandao, Maria Angela; Andrade, Paula D; Costa, Sandra CB; Escanhoela, Cecilia AF; Vassallo, Jose; Porta, Gilda; De Tommaso, Adriana MA; Hessel, Gabriel

    2009-01-01

    AIM: To determine cytomegalovirus (CMV) frequency in neonatal intrahepatic cholestasis by serology, histological revision (searching for cytomegalic cells), immunohistochemistry, and polymerase chain reaction (PCR), and to verify the relationships among these methods. METHODS: The study comprised 101 non-consecutive infants submitted for hepatic biopsy between March 1982 and December 2005. Serological results were obtained from the patient’s files and the other methods were performed on paraffin-embedded liver samples from hepatic biopsies. The following statistical measures were calculated: frequency, sensibility, specific positive predictive value, negative predictive value, and accuracy. RESULTS: The frequencies of positive results were as follows: serology, 7/64 (11%); histological revision, 0/84; immunohistochemistry, 1/44 (2%), and PCR, 6/77 (8%). Only one patient had positive immunohistochemical findings and a positive PCR. The following statistical measures were calculated between PCR and serology: sensitivity, 33.3%; specificity, 88.89%; positive predictive value, 28.57%; negative predictive value, 90.91%; and accuracy, 82.35%. CONCLUSION: The frequency of positive CMV varied among the tests. Serology presented the highest positive frequency. When compared to PCR, the sensitivity and positive predictive value of serology were low. PMID:19610143

  13. Trial-by-Trial Modulation of Associative Memory Formation by Reward Prediction Error and Reward Anticipation as Revealed by a Biologically Plausible Computational Model.

    PubMed

    Aberg, Kristoffer C; Müller, Julia; Schwartz, Sophie

    2017-01-01

    Anticipation and delivery of rewards improves memory formation, but little effort has been made to disentangle their respective contributions to memory enhancement. Moreover, it has been suggested that the effects of reward on memory are mediated by dopaminergic influences on hippocampal plasticity. Yet, evidence linking memory improvements to actual reward computations reflected in the activity of the dopaminergic system, i.e., prediction errors and expected values, is scarce and inconclusive. For example, different previous studies reported that the magnitude of prediction errors during a reinforcement learning task was a positive, negative, or non-significant predictor of successfully encoding simultaneously presented images. Individual sensitivities to reward and punishment have been found to influence the activation of the dopaminergic reward system and could therefore help explain these seemingly discrepant results. Here, we used a novel associative memory task combined with computational modeling and showed independent effects of reward-delivery and reward-anticipation on memory. Strikingly, the computational approach revealed positive influences from both reward delivery, as mediated by prediction error magnitude, and reward anticipation, as mediated by magnitude of expected value, even in the absence of behavioral effects when analyzed using standard methods, i.e., by collapsing memory performance across trials within conditions. We additionally measured trait estimates of reward and punishment sensitivity and found that individuals with increased reward (vs. punishment) sensitivity had better memory for associations encoded during positive (vs. negative) prediction errors when tested after 20 min, but a negative trend when tested after 24 h. In conclusion, modeling trial-by-trial fluctuations in the magnitude of reward, as we did here for prediction errors and expected value computations, provides a comprehensive and biologically plausible description of the dynamic interplay between reward, dopamine, and associative memory formation. Our results also underline the importance of considering individual traits when assessing reward-related influences on memory.

  14. Comparison of the Walz Nomogram and Presence of Secondary Circulating Prostate Cells for Predicting Early Biochemical Failure after Radical Prostatectomy for Prostate Cancer in Chilean Men.

    PubMed

    Murray, Nigel P; Reyes, Eduardo; Orellana, Nelson; Fuentealba, Cynthia; Jacob, Omar

    2015-01-01

    To determine the utility of secondary circulating prostate cells for predicting early biochemical failure after radical prostatectomy for prostate cancer and compare the results with the Walz nomagram. A single centre, prospective study of men with prostate cancer treated with radical prostatectomy between 2004 and 2014 was conducted, with registration of clinical-pathological details, total serum PSA pre-surgery, Gleason score, extracapsular extension, positive surgical margins, infiltration of lymph nodes, seminal vesicles and pathological stage. Secondary circulating prostate cells were obtained using differential gel centrifugation and assessed using standard immunocytochemistry with anti-PSA. Biochemical failure was defined as a PSA >0.2ng/ml, predictive values werecalculated using the Walz nomagram and CPC detection. A total of 326 men participated, with a median follow up of 5 years; 64 had biochemical failure within two years. Extracapsular extension, positive surgical margins, pathological stage, Gleason score ≥ 8, infiltration of seminal vesicles and lymph nodes were all associated with higher risk of biochemical failure. The discriminative value for the nomogram and circulating prostate cells was high (AUC >0.80), predictive values were higher for circulating prostate cell detection, with a negative predictive value of 99%, sensitivity of 96% and specificity of 75%. The nomagram had good predictive power to identify men with a high risk of biochemical failure within two years. The presence of circulating prostate cells had the same predictive power, with a higher sensitivity and negative predictive value. The presence of secondary circulating prostate cells identifies a group of men with a high risk of early biochemical failure. Those negative for secondary CPCs have a very low risk of early biochemical failure.

  15. Neural Reward and Punishment Sensitivity in Cigarette Smokers

    PubMed Central

    Potts, Geoffrey F.; Bloom, Erika; Evans, David E.; Drobes, David J.

    2014-01-01

    Background Nicotine addiction remains a major public health problem but the neural substrates of addictive behavior remain unknown. One characteristic of smoking behavior is impulsive choice, selecting the immediate reward of smoking despite the potential long-term negative consequences. This suggests that drug users, including cigarette smokers, may be more sensitive to rewards and less sensitive to punishment. Methods We used event-related potentials (ERPs) to test the hypothesis that smokers are more responsive to reward signals and less responsive to punishment, potentially predisposing them to risky behavior. We conducted two experiments, one using a reward prediction design to elicit a Medial Frontal Negativity (MFN) and one using a reward- and punishment-motivated flanker task to elicit an Error Related Negativity (ERN), ERP components thought to index activity in the cortical projection of the dopaminergic reward system. Results and Conclusions The smokers had a greater MFN response to unpredicted rewards, and non-smokers, but not smokers, had a larger ERN on punishment motivated trials indicating that smokers are more reward sensitive and less punishment sensitive than nonsmokers, overestimating the appetitive value and underestimating aversive outcomes of stimuli and actions. PMID:25292454

  16. LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.

    PubMed

    Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel

    2017-01-07

    Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.

  17. Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.

    PubMed

    Chan, E L; Brandt, K; Horsman, G

    1995-11-01

    Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.

  18. [TSH anti-receptor antibodies in Graves' disease].

    PubMed

    Sérgio, M R; Godinho, C; Guerra, L; Agapito, A; Fonseca, F; Costa, C

    1996-01-01

    The purpose of this study was to evaluate the sensitivity, specificity and predictive value of thyrotropin receptor antibody (TRAb) in the diagnosis of Graves disease. TRAb was tested by an isotopic receptor assay-TRAK Henning-in 80 newly diagnosed, untreated Graves disease patients (group I), 63 with other thyroid diseases (group II) and 60 controls (group III). In group I, 11 patients were TRAb negative and 7 were considered in the gray area (TRAb between 9 and 14 U/L). In group II, only 2 patients had TRAb 9 U/l and all controls were TRAb negative. For statistical analysis patients with TRAb in gray area were excluded. Sensitivity and specificity for this assay were 84.5 and 100% respectively. Predictive value of 100% affords certainty that a hyperthyroid patient with a positive TRAb has Graves disease, not sequining a scintigram.

  19. Prenatal diagnosis using polymerase chain reaction on amniotic fluid for congenital toxoplasmosis.

    PubMed

    Romand, S; Wallon, M; Franck, J; Thulliez, P; Peyron, F; Dumon, H

    2001-02-01

    To evaluate sensitivity, specificity, and predictive values of a prenatal amniotic fluid (AF) polymerase chain reaction (PCR) test for diagnosis of congenital toxoplasmosis. A multicenter prospective study was done on 271 women with proved primary Toxoplasma infection during pregnancy and who had amniocentesis for prenatal diagnosis by PCR. Live-born infants were eligible for analysis only if a serologic follow-up could assess a definitive infection status. Of the 270 evaluable cases, 75 were congenitally infected, 48 of whom had a positive PCR at prenatal diagnosis. Overall sensitivity of PCR on AF was estimated at 64% (95% confidence interval [CI] 53.1%, 74.9%), negative predictive value of 87.8% (95% CI 83.5%, 92.1%), whereas specificity and positive predictive value were 100% (95% CIs 98%, 100% and 92.3%, 100%, respectively). Among cases with congenital toxoplasmosis, there were no significant differences between those with positive or negative PCR with regard to median gestational age at maternal infection, interval between maternal infection and amniocentesis, or duration of treatment before amniocentesis. However, sensitivity of PCR was found to be significantly higher for maternal infections that occurred between 17 and 21 weeks' gestation (P <.02). A negative PCR of AF cannot rule out congenital infection. In this case, continuation of treatment with spiramycin combined with ultrasonographic follow-up and postnatal follow-up are warranted. Our results also suggest presumptive treatment combining pyrimethamine and sulfonamides in case of maternal infection occurring late in pregnancy.

  20. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    PubMed

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  1. Fatty liver index and hepatic steatosis index for prediction of non-alcoholic fatty liver disease in type 1 diabetes.

    PubMed

    Sviklāne, Laura; Olmane, Evija; Dzērve, Zane; Kupčs, Kārlis; Pīrāgs, Valdis; Sokolovska, Jeļizaveta

    2018-01-01

    Little is known about the diagnostic value of hepatic steatosis index (HSI) and fatty liver index (FLI), as well as their link to metabolic syndrome in type 1 diabetes mellitus. We have screened the effectiveness of FLI and HSI in an observational pilot study of 40 patients with type 1 diabetes. FLI and HSI were calculated for 201 patients with type 1 diabetes. Forty patients with FLI/HSI values corresponding to different risk of liver steatosis were invited for liver magnetic resonance study. In-phase/opposed-phase technique of magnetic resonance was used. Accuracy of indices was assessed from the area under the receiver operating characteristic curve. Twelve (30.0%) patients had liver steatosis. For FLI, sensitivity was 90%; specificity, 74%; positive likelihood ratio, 3.46; negative likelihood ratio, 0.14; positive predictive value, 0.64; and negative predictive value, 0.93. For HSI, sensitivity was 86%; specificity, 66%; positive likelihood ratio, 1.95; negative likelihood ratio, 0.21; positive predictive value, 0.50; and negative predictive value, 0.92. Area under the receiver operating characteristic curve for FLI was 0.86 (95% confidence interval [0.72; 0.99]); for HSI 0.75 [0.58; 0.91]. Liver fat correlated with liver enzymes, waist circumference, triglycerides, and C-reactive protein. FLI correlated with C-reactive protein, liver enzymes, and blood pressure. HSI correlated with waist circumference and C-reactive protein. FLI ≥ 60 and HSI ≥ 36 were significantly associated with metabolic syndrome and nephropathy. The tested indices, especially FLI, can serve as surrogate markers for liver fat content and metabolic syndrome in type 1 diabetes. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  2. Improving discrimination in antepartum depression screening using the Edinburgh Postnatal Depression Scale.

    PubMed

    Venkatesh, Kartik K; Kaimal, Anjali J; Castro, Victor M; Perlis, Roy H

    2017-05-01

    Universal screening of pregnant women for postpartum depression has recently been recommended; however, optimal application of depression screening tools in stratifying risk has not been defined. The current study examines new approaches to improve the ability of the Edinburgh Postnatal Depression Scale (EPDS) to stratify risk for postpartum depression, including alternate cut points, use of a continuous measure, and incorporation of other putative risk factors. An observational cohort study of 4939 women screened both antepartum and postpartum with a negative EPDS screen antepartum(i.e. EPDS<10). The primary outcome was a probable postpartum major depressive episode(EPDS cut-off ≥10). Area under the receiver operating characteristics curve(AUC), sensitivity, specificity, and predictive values were calculated. 287 women(5.8%) screened positive for postpartum depression. An antepartum EPDS cut-off<5 optimally identified women with a low risk of postpartum depression with a negative predictive value of 97.6%; however, overall discrimination was modest(AUC 0.66, 95%CI: 0.64-0.69); sensitivity was 78.7%, and specificity was 53.8%, and the positive predictive value was low at 9.5%. The negative predictive values were similar(>95%) at all antepartum EPDS cut-off values from 4 to 8. Discrimination was improved(AUC ranging from 0.70 to 0.73) when the antepartum EPDS was combined with a prior history of major depressive disorder before pregnancy. An inability to assess EPDS subscales and a relatively low prevalence of depression in this cohort. Though an antepartum EPDS cut-off score <5 yielded the greatest discrimination identifying women at low risk for postpartum depression, the negative predictive value was insufficient to substitute for postpartum screening. Copyright © 2017. Published by Elsevier B.V.

  3. Role of specimen US for predicting resection margin status in breast conserving therapy.

    PubMed

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  4. Serum Protein Electrophoresis in the Evaluation of Lytic Bone Lesions

    PubMed Central

    Nystrom, Lukas M.; Buckwalter, Joseph A.; Syrbu, Sergei; Miller, Benjamin J.

    2013-01-01

    Serum protein electrophoresis (SPEP) is often obtained at the initial evaluation of a radiolucent bone lesion of unknown etiology. The results are considered convincing evidence of the presence or absence of a plasma cell neoplasm. The sensitivity and specificity of the SPEP have not been reported in this clinical scenario. Our purpose is to assess the diagnostic value of the SPEP in the initial work-up of the radiolucent bone lesion. We identified 182 patients undergoing evaluation of a radiolucent bone lesion that included tissue biopsy and an SPEP value. We then calculated the sen-sitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of SPEP as a diagnostic test for a plasma cell neo-plasm in this clinical scenario. Forty-six of 182 (25.3%) patients in our series were diagnosed with a plasma cell neo-plasm by histopathologic analysis. The sensitivity of SPEP was 71% and the specificity was 83%. PPV was 47% and NPV was 94%. When analyzing only those presenting with multiple lesions, the percentage of patients diag-nosed with multiple myeloma increased to 44.7% (34 of 76 patients). The SPEP, however, did not have a substantially increased diagnostic accuracy with sensitivity of 71%, specificity 79%, PPV 40% and NPV 93%. SPEP lacks sensitivity and positive predictive value to provide a definitive diagnosis of myeloma in radiolucent bone lesions, but has a high negative predictive value which may make it useful in ruling out the disease. We recommend that this test either be performed in conjunction with urine electrophoresis, immunofixation electro-phoresis and free light chain assay, or after biopsy confirming the diagnosis of myeloma. PMID:24027470

  5. Interactive effect of negative affectivity and anxiety sensitivity in terms of mental health among Latinos in primary care.

    PubMed

    Zvolensky, Michael J; Paulus, Daniel J; Bakhshaie, Jafar; Garza, Monica; Ochoa-Perez, Melissa; Medvedeva, Angela; Bogiaizian, Daniel; Robles, Zuzuky; Manning, Kara; Schmidt, Norman B

    2016-09-30

    From a public health perspective, primary care medical settings represent a strategic location to address mental health disapirty among Latinos. Yet, there is little empirical work that addresses affective vulnerability processes for mental health problems in such settings. To help address this gap in knowledge, the present investigation examined an interactive model of negative affectivity (tendency to experience negative mood states) and anxiety sensitivity (fear of the negative consequences of aversive sensations) among a Latino sample in primary care in terms of a relatively wide range of anxiety/depression indices. Participants included 390 Latino adults (Mage=38.7, SD=11.3; 86.9% female; 95.6% reported Spanish as first language) from a primary care health clinic. Primary dependent measures included depressive, suicidal, social anxiety, and anxious arousal symptoms, number of mood and anxiety disorders, and disability. Consistent with prediction, the interaction between negative affectivity and anxiety sensitivity was significantly related to suicidal, social anxiety, and anxious arousal symptoms, as well as number of mood/anxiety diagnoses and disability among the primary care Latino sample. The form of the interactions indicated a synergistic effect, such that the greatest levels of each outcome were found among those with high negative affectivity and high anxiety sensitivity. There was a trending interaction for depressive symptoms. Overall, these data provide novel empirical evidence suggesting that there is a clinically-relevant interplay between anxiety sensitivity and negative affectivity in regard to the expression of anxiety and depressive symptoms among a Latino primary care sample. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Validity of the International Classification of Diseases 10th revision code for hyperkalaemia in elderly patients at presentation to an emergency department and at hospital admission

    PubMed Central

    Fleet, Jamie L; Shariff, Salimah Z; Gandhi, Sonja; Weir, Matthew A; Jain, Arsh K; Garg, Amit X

    2012-01-01

    Objectives Evaluate the validity of the International Classification of Diseases, 10th revision (ICD-10) code for hyperkalaemia (E87.5) in two settings: at presentation to an emergency department and at hospital admission. Design Population-based validation study. Setting 12 hospitals in Southwestern Ontario, Canada, from 2003 to 2010. Participants Elderly patients with serum potassium values at presentation to an emergency department (n=64 579) and at hospital admission (n=64 497). Primary outcome Sensitivity, specificity, positive-predictive value and negative-predictive value. Serum potassium values in patients with and without a hyperkalaemia code (code positive and code negative, respectively). Results The sensitivity of the best-performing ICD-10 coding algorithm for hyperkalaemia (defined by serum potassium >5.5 mmol/l) was 14.1% (95% CI 12.5% to 15.9%) at presentation to an emergency department and 14.6% (95% CI 13.3% to 16.1%) at hospital admission. Both specificities were greater than 99%. In the two settings, the positive-predictive values were 83.2% (95% CI 78.4% to 87.1%) and 62.0% (95% CI 57.9% to 66.0%), while the negative-predictive values were 97.8% (95% CI 97.6% to 97.9%) and 96.9% (95% CI 96.8% to 97.1%). In patients who were code positive for hyperkalaemia, median (IQR) serum potassium values were 6.1 (5.7 to 6.8) mmol/l at presentation to an emergency department and 6.0 (5.1 to 6.7) mmol/l at hospital admission. For code-negative patients median (IQR) serum potassium values were 4.0 (3.7 to 4.4) mmol/l and 4.1 (3.8 to 4.5) mmol/l in each of the two settings, respectively. Conclusions Patients with hospital encounters who were ICD-10 E87.5 hyperkalaemia code positive and negative had distinct higher and lower serum potassium values, respectively. However, due to very low sensitivity, the incidence of hyperkalaemia is underestimated. PMID:23274674

  7. Value of a negative aeroallergen skin-prick test result in the diagnosis of asthma in young adults: correlative study with methacholine challenge testing.

    PubMed

    Graif, Yael; Yigla, Mordechai; Tov, Naveh; Kramer, Mordechai R

    2002-09-01

    None of the existing tests for the diagnosis of asthma are considered to be definitive. Certain circumstances require prompt diagnosis, and a test able to predict the absence of asthma would be very useful. To evaluate the contribution of a skin-prick test (SPT) to the diagnostic workup of subjects with suspected asthma. The study included three groups of subjects aged 18 to 24 years: group A, asthmatic patients (n = 175); group B, control subjects (n = 100); and group C, subjects with suspected asthma (n = 150) with normal spirometry findings and a negative exercise challenge test result. All underwent an SPT to a battery of common aeroallergens, and group C underwent a methacholine challenge test (MCT) in addition. The sensitivity, specificity, positive predictive value, and negative predictive values (NPV) of the SPT were calculated using provocative concentrations of methacholine causing a 20% fall in FEV(1) (PC(20)) of < 4 mg/mL and < 8 mg/mL as diagnostic cutoff values for asthma in the MCT. Bayes' formula was used to determine posttest probabilities of having asthma, both for positive and negative SPT results. A positive SPT result to at least one allergen was found in 95.5%, 54%, and 69% of patients in the three groups, respectively. The sensitivity, specificity, and NPV of the SPT were 90.7%, 52.0%, and 84.8%, respectively, with a cutoff value of PC(20) < 8 mg/mL. The lower cutoff, PC(20) < 4 mg/mL, increased the sensitivity and NPV to 98.2% and 97.8%, respectively. A negative SPT result decreased the probability of having asthma by 10-fold to 20-fold in subjects whose pretest probability was low to moderate. Incorporating an SPT into the workup of subjects with suspected asthma can reduce the cost of this process significantly. The SPT may be used as a simple, fast, safe, inexpensive, and reliable method to predict the absence of asthma in young adults.

  8. Performance of blend sign in predicting hematoma expansion in intracerebral hemorrhage: A meta-analysis.

    PubMed

    Yu, Zhiyuan; Zheng, Jun; Guo, Rui; Ma, Lu; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao

    2017-12-01

    Hematoma expansion is independently associated with poor outcome in intracerebral hemorrhage (ICH). Blend sign is a simple predictor for hematoma expansion on non-contrast computed tomography. However, its accuracy for predicting hematoma expansion is inconsistent in previous studies. This meta-analysis is aimed to systematically assess the performance of blend sign in predicting hematoma expansion in ICH. A systematic literature search was conducted. Original studies about predictive accuracy of blend sign for hematoma expansion in ICH were included. Pooled sensitivity, specificity, positive and negative likelihood ratios were calculated. Summary receiver operating characteristics curve was constructed. Publication bias was assessed by Deeks' funnel plot asymmetry test. A total of 5 studies with 2248 patients were included in this meta-analysis. The pooled sensitivity, specificity, positive and negative likelihood ratios of blend sign for predicting hematoma expansion were 0.28, 0.92, 3.4 and 0.78, respectively. The area under the curve (AUC) was 0.85. No significant publication bias was found. This meta-analysis demonstrates that blend sign is a useful predictor with high specificity for hematoma expansion in ICH. Further studies with larger sample size are still necessary to verify the accuracy of blend sign for predicting hematoma expansion. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Predictive values of thermal and electrical dental pulp tests: a clinical study.

    PubMed

    Villa-Chávez, Carlos E; Patiño-Marín, Nuria; Loyola-Rodríguez, Juan P; Zavala-Alonso, Norma V; Martínez-Castañón, Gabriel A; Medina-Solís, Carlo E

    2013-08-01

    For a diagnostic test to be useful, it is necessary to determine the probability that the test will provide the correct diagnosis. Therefore, it is necessary to calculate the predictive value of diagnostics. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values, accuracy, and reproducibility of thermal and electrical tests of pulp sensitivity. The thermal tests studied were the 1, 1, 1, 2-tetrafluoroethane (cold) and hot gutta-percha (hot) tests. For the electrical test, the Analytic Technology Pulp Tester (Analytic Technology, Redmond, WA) was used. A total of 110 teeth were tested: 60 teeth with vital pulp and 50 teeth with necrotic pulps (disease prevalence of 45%). The ideal standard was established by direct pulp inspection. The sensitivities of the diagnostic tests were 0.88 for the cold test, 0.86 for the heat test, and 0.76 for the electrical test, and the specificity was 1.0 for all 3 tests. The negative predictive value was 0.90 for the cold test, 0.89 for the heat test, and 0.83 for the electrical test, and the positive predictive value was 1.0 for all 3 tests. The highest accuracy (0.94) and reproducibility (0.88) were observed for the cold test. The cold test was the most accurate method for diagnostic testing. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    PubMed

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  11. X-ray requesting patterns before and after introduction of the Ottawa Knee Rules in a UK emergency department.

    PubMed

    Atkinson, Paul; Boyle, Adrian; Chisholm, Edward

    2004-08-01

    To compare knee radiology requesting rates among junior doctors before and after the formal introduction of the Ottawa Knee Rules (OKR) in a UK emergency department (ED), and to test the validity of the OKR for decisions on the use of radiography for acute, isolated knee injuries. All junior doctors in a district general hospital ED seeing adult patients with isolated knee injuries completed a questionnaire before and after the introduction of the OKR. All patients were followed up to obtain a final diagnosis. The outcome measures were: adherence to the OKR, the presence of a fracture and whether a radiograph had been requested. The results were analysed to determine the sensitivity, specificity, positive and negative predictive values of the OKR. Comparisons between the request rate for knee radiography before and after the introduction of the OKR were made. A total of 130 patients were enrolled and followed up over a 3-month period; 58 before and 72 after OKR introduction. The OKR had a sensitivity of 100% (71.8-100%), a specificity of 55.1% (46.1-64.1%), a positive predictive value of 18.5% (9.03-27.9%) and a negative predictive value of 100% (87.8-100%) for the detection of bony injury. The introduction of the OKR did not result in a significant reduction in the number of radiographs performed (58.6-55.6%; P= 0.726). This study shows the OKR to be a highly sensitive clinical guide with a high negative predictive value in the setting of a UK ED. It suggests that the reduction in radiograph requests seen elsewhere may not be as apparent in this setting.

  12. Is the 15∆ Base in Prism Test Reliable for Detection of Amblyopia in Anisometropic Patients?

    PubMed

    Burggraaf, F; Verkaik-Rijneveld, M C; Wubbels, R J; de Jongh, E

    2017-09-01

    The 15∆ base in prism test (15∆BIPT) introduced by Gobin is often used in The Netherlands to detect fixation preference, especially in young and preverbal children in whom a reliable measurement of the visual acuity (VA) is difficult. It is assumed that the fixation preference detected by the 15∆BIPT can be used to predict the presence of amblyopia. The aim of this retrospective case note review was to investigate the accuracy of the 15∆BIPT in detection of amblyopia in anisometropic patients. Four hundred and twelve files of anisometropic patients visiting the orthoptic department of The Rotterdam Eye Hospital were analyzed. Amblyopia was defined as an intraocular difference in VA of 2 or more Snellen lines. The sensitivity, specificity, and positive and negative predictive values of the 15∆BIPT were calculated and the receiver operating characteristic (ROC) curve was plotted. One hundred and fifty-two patients ranging from 3.3-13.1 years of age (median 5.4 years) met the inclusion criteria. One hundred and two patients were diagnosed with amblyopia. Best-corrected median VA of the best eye was 1.0 (range 0.5-1.2) and the worst eye 0.70 (range 0.05-1.2). Sensitivity of the 15∆BIPT (based on detecting amblyopia) was 34.3%. Specificity was 88.0%. The positive predictive value was 85.4% versus a negative predictive value of 39.6%. The area under the ROC curve (AUC) was 0.65 (95% CI 0.56-0.74). The low sensitivity, large number of false negatives and the AUC show that the 15∆BIPT can be considered a poor test for detecting amblyopia in anisometropic patients.

  13. Comparison of wheat and rye flour solutions for skin prick testing: a multi-centre study (Stad 1).

    PubMed

    van Kampen, V; Merget, R; Rabstein, S; Sander, I; Bruening, T; Broding, H C; Keller, C; Muesken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M

    2009-12-01

    Skin prick testing (SPT) is the basic method for diagnosing IgE-mediated allergies. However, skin reactivity is related to the quality of allergen extracts, which are often poorly defined for occupational allergens. To compare wheat and rye flour SPT solutions from different producers. Standardized SPTs were performed in seven allergy centres with wheat and rye flour solutions from four producers in 125 symptomatic bakers. Optimal cut-off levels for weal sizes were assessed with the Youden Index. Comparisons between SPT results of different solutions were made with flour-specific IgE (sIgE) as the gold standard. Sensitivities, specificities, positive and negative predictive values, and test efficiencies were calculated and compared with McNemar and chi(2)-tests. The influence of the choice of the gold standard (sIgE or challenge) test was examined for 95 subjects. Additionally, SPT solutions were analysed for protein and antigen content. The optimal cut-off level for all SPT solutions was a weal size of >or=1.5 mm. While differences between wheat and rye flours were small, differences between producers were important. Variability of sensitivities (0.31-0.96), negative predictive values (0.42-0.91), and test efficiencies (0.54-0.90) were higher than variations of specificities (0.74-1.00) and positive predictive values (0.88-1.00). Similar results were obtained when using challenge test results as the gold standard. Variability could be explained by the different antigen contents of the SPT solutions. There is a wide variability of SPT solutions for wheat and rye flour from different producers, mainly with respect to sensitivities, negative predictive values, and test efficiencies. Improvement and standardization of SPT solutions used for the diagnosis of baker's asthma are highly recommended.

  14. Getting the Best Return on Your Screening Investment: An Analysis of the Suicidal Ideation Questionnaire and Reynolds Adolescent Depression Scale

    ERIC Educational Resources Information Center

    Gutierrez, Peter M.; Osman, Augustine

    2009-01-01

    Data from 64 adolescent inpatients admitted for serious suicidal ideation, 50 adolescent inpatients admitted following a suicide attempt, and 56 randomly selected high school control participants were used to evaluate the sensitivity, specificity, positive predictive value, and negative predictive value of the Suicidal Ideation Questionnaire (SIQ)…

  15. Evaluation of a Records-Review Surveillance System Used to Determine the Prevalence of Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Avchen, Rachel Nonkin; Wiggins, Lisa D.; Devine, Owen; Van Naarden Braun, Kim; Rice, Catherine; Hobson, Nancy C.; Schendel, Diana; Yeargin-Allsopp, Marshalyn

    2011-01-01

    We conducted the first study that estimates the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of a population-based autism spectrum disorders (ASD) surveillance system developed at the Centers for Disease Control and Prevention. The system employs a records-review methodology that yields ASD…

  16. Comparison between presepsin and procalcitonin in early diagnosis of neonatal sepsis.

    PubMed

    Iskandar, Agustin; Arthamin, Maimun Z; Indriana, Kristin; Anshory, Muhammad; Hur, Mina; Di Somma, Salvatore

    2018-05-09

    Neonatal sepsis remains worldwide one of the leading causes of morbidity and mortality in both term and preterm infants. Lower mortality rates are related to timely diagnostic evaluation and prompt initiation of empiric antibiotic therapy. Blood culture, as gold standard examination for sepsis, has several limitations for early diagnosis, so that sepsis biomarkers could play an important role in this regard. This study was aimed to compare the value of the two biomarkers presepsin and procalcitonin in early diagnosis of neonatal sepsis. This was a prospective cross-sectional study performed, in Saiful Anwar General Hospital Malang, Indonesia, in 51 neonates that fulfill the criteria of systemic inflammatory response syndrome (SIRS) with blood culture as diagnostic gold standard for sepsis. At reviewer operating characteristic (ROC) curve analyses, using a presepsin cutoff of 706,5 pg/mL, the obtained area under the curve (AUCs) were: sensitivity = 85.7%, specificity = 68.8%, positive predictive value = 85.7%, negative predictive value = 68.8%, positive likelihood ratio = 2.75, negative likelihood ratio = 0.21, and accuracy = 80.4%. On the other hand, with a procalcitonin cutoff value of 161.33 pg/mL the obtained AUCs showed: sensitivity = 68.6%, specificity = 62.5%, positive predictive value = 80%, negative predictive value = 47.6%, positive likelihood ratio = 1.83, the odds ratio negative = 0.5, and accuracy = 66.7%. In early diagnosis of neonatal sepsis, compared with procalcitonin, presepsin seems to provide better early diagnostic value with consequent possible faster therapeutical decision making and possible positive impact on outcome of neonates.

  17. Diagnostic usefulness of MUC1 and MUC4 for distinguishing between metastatic adenocarcinoma cells and reactive mesothelial cells in effusion cell blocks.

    PubMed

    Cho, Jin Seong; Kim, Ga-Eon; Lee, Ji Shin; Lee, Jae Hyuk; Nam, Jong Hee; Choi, Chan

    2013-01-01

    The aim of our study was to determine the diagnostic value of MUC1 and MUC4 for distinguishing between metastatic adenocarcinoma cells (MAC) and reactive mesothelial cells (RMC) in effusion fluids. A total of 237 cell block specimens from pleural and peritoneal effusions, including 196 malignant effusions with MAC and 41 benign effusions with RMC, were stained with antibodies against MUC1 and MUC4. Membranous staining with or without cytoplasmic staining was considered to be positive. MUC1 immunoreactivity was observed in 194 (99.0%) of 196 cases of MAC and in 20 (48.8%) of 41 cases of RMC. MUC4 immunoreactivity was observed in 174 (88.8%) of 196 cases of MAC and in 4 (9.8%) of 41 cases of RMC. For distinguishing MAC from RMC, the MUC1 reactivity was found to be 99.0% sensitive and 51.2% specific with a positive predictive value of 90.7% and a negative predictive value of 91.3%. The sensitivity of MUC4 for MAC was 88.8%, the specificity was 90.2%, the negative predictive value was 62.7%, and the positive predictive value was 97.8%. Our data suggest that MUC4 appears to be a sensitive and specific marker for differentiating between MAC and RMC. Copyright © 2013 S. Karger AG, Basel.

  18. Validation of automatic wheeze detection in patients with obstructed airways and in healthy subjects.

    PubMed

    Guntupalli, Kalpalatha K; Alapat, Philip M; Bandi, Venkata D; Kushnir, Igal

    2008-12-01

    Computerized lung-sound analysis is a sensitive and quantitative method to identify wheezing by its typical pattern on spectral analysis. We evaluated the accuracy of the VRI, a multi-sensor, computer-based device with an automated technique of wheeze detection. The method was validated in 100 sound files from seven subjects with asthma or chronic obstructive pulmonary disease and seven healthy subjects by comparison of auscultation findings, examination of audio files, and computer detection of wheezes. Three blinded physicians identified 40 sound files with wheezes and 60 sound files without wheezes. Sensitivity and specificity were 83% and 85%, respectively. Negative predictive value and positive predictive value were 89% and 79%, respectively. Overall inter-rater agreement was 84%. False positive cases were found to contain sounds that simulate wheezes, such as background noises with high frequencies or strong noises from the throat that could be heard and identified without a stethoscope. The present findings demonstrate that the wheeze detection algorithm has good accuracy, sensitivity, specificity, negative predictive value and positive predictive value for wheeze detection in regional analyses with a single sensor and multiple sensors. Results are similar to those reported in the literature. The device is user-friendly, requires minimal patient effort, and, distinct from other devices, it provides a dynamic image of breath sound distribution with wheeze detection output in less than 1 minute.

  19. Evaluation of GeneXpert MTB/RIF for detection of pulmonary tuberculosis at peripheral tuberculosis clinics.

    PubMed

    Shao, Yan; Peng, Hong; Chen, Cheng; Zhu, Tao; Ji, Ming; Jiang, Wei; Zhu, Wei; Zhai, Xiang Jun; Lu, Wei

    2017-04-01

    Tuberculosis is one of the most common infectious diseases in China, while delayed patient finding obstructed disease control, especially for smear-negative patients. The current study was undertaken to evaluate the diagnostic accuracy of GeneXpert MTB/RIF compared with conventional methods in the detection of pulmonary tuberculosis patients. A total of 295 spot sputum samples from confirmed pulmonary tuberculosis patients were evaluated from September 2014 to June 2015. Each sample was examined by acid-fast bacillus smear microscopy, culture and GeneXpert MTB/RIF. The sputum culture on Löwenstein-Jensen (L-J) was considered as the gold-standard. After testing by smear, 68.81% (203/295) was negative and 31.19% (92/295) was positive. As the gold-standard, L-J culture detected 37.97% (112/295) positive of all specimens, while the positivity for GeneXpert MTB/RIF was 46.44% (137/295). Compared with L-J culture, the combined sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for GeneXpert MTB/RIF were 94.64%, 82.97%, 77.37% and 96.18% respectively. For smear-negative specimens, the sensitivity, specificity, PPV and NPV for GeneXpert MTB/RIF were 96.00%, 83.05%, 44.44% and 99.32%; while for smear-positive specimens, the corresponding accuracy values were 94.25%, 80.00%, 98.80% and 44.44%. The findings of study indicated that GeneXpert MTB/RIF assay demonstrated a high sensitivity in detecting Mycobacterium tuberculosis compared to smear method and a high NPV among smear negative patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Predictive value of T2 relative signal intensity for response to somatostatin analogs in newly diagnosed acromegaly.

    PubMed

    Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei

    2016-11-01

    The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.

  1. High-definition endoscopy with digital chromoendoscopy for histologic prediction of distal colorectal polyps.

    PubMed

    Rath, Timo; Tontini, Gian E; Nägel, Andreas; Vieth, Michael; Zopf, Steffen; Günther, Claudia; Hoffman, Arthur; Neurath, Markus F; Neumann, Helmut

    2015-10-22

    Distal diminutive colorectal polyps are common and accurate endoscopic prediction of hyperplastic or adenomatous polyp histology could reduce procedural time, costs and potential risks associated with the resection. Within this study we assessed whether digital chromoendoscopy can accurately predict the histology of distal diminutive colorectal polyps according to the ASGE PIVI statement. In this prospective cohort study, 224 consecutive patients undergoing screening or surveillance colonoscopy were included. Real time histology of 121 diminutive distal colorectal polyps was evaluated using high-definition endoscopy with digital chromoendoscopy and the accuracy of predicting histology with digital chromoendoscopy was assessed. The overall accuracy of digital chromoendoscopy for prediction of adenomatous polyp histology was 90.1 %. Sensitivity, specificity, positive and negative predictive values were 93.3, 88.7, 88.7, and 93.2 %, respectively. In high-confidence predictions, the accuracy increased to 96.3 % while sensitivity, specificity, positive and negative predictive values were calculated as 98.1, 94.4, 94.5, and 98.1 %, respectively. Surveillance intervals with digital chromoendoscopy were correctly predicted with >90 % accuracy. High-definition endoscopy in combination with digital chromoendoscopy allowed real-time in vivo prediction of distal colorectal polyp histology and is accurate enough to leave distal colorectal polyps in place without resection or to resect and discard them without pathologic assessment. This approach has the potential to reduce costs and risks associated with the redundant removal of diminutive colorectal polyps. ClinicalTrials NCT02217449.

  2. Predicting drug-induced liver injury in human with Naïve Bayes classifier approach.

    PubMed

    Zhang, Hui; Ding, Lan; Zou, Yi; Hu, Shui-Qing; Huang, Hai-Guo; Kong, Wei-Bao; Zhang, Ji

    2016-10-01

    Drug-induced liver injury (DILI) is one of the major safety concerns in drug development. Although various toxicological studies assessing DILI risk have been developed, these methods were not sufficient in predicting DILI in humans. Thus, developing new tools and approaches to better predict DILI risk in humans has become an important and urgent task. In this study, we aimed to develop a computational model for assessment of the DILI risk with using a larger scale human dataset and Naïve Bayes classifier. The established Naïve Bayes prediction model was evaluated by 5-fold cross validation and an external test set. For the training set, the overall prediction accuracy of the 5-fold cross validation was 94.0 %. The sensitivity, specificity, positive predictive value and negative predictive value were 97.1, 89.2, 93.5 and 95.1 %, respectively. The test set with the concordance of 72.6 %, sensitivity of 72.5 %, specificity of 72.7 %, positive predictive value of 80.4 %, negative predictive value of 63.2 %. Furthermore, some important molecular descriptors related to DILI risk and some toxic/non-toxic fragments were identified. Thus, we hope the prediction model established here would be employed for the assessment of human DILI risk, and the obtained molecular descriptors and substructures should be taken into consideration in the design of new candidate compounds to help medicinal chemists rationally select the chemicals with the best prospects to be effective and safe.

  3. TargetMiner: microRNA target prediction with systematic identification of tissue-specific negative examples.

    PubMed

    Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna

    2009-10-15

    Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu

  4. Usefulness and limitations of various guinea-pig test methods in detecting human skin sensitizers-validation of guinea-pig tests for skin hypersensitivity.

    PubMed

    Marzulli, F; Maguire, H C

    1982-02-01

    Several guinea-pig predictive test methods were evaluated by comparison of results with those obtained with human predictive tests, using ten compounds that have been used in cosmetics. The method involves the statistical analysis of the frequency with which guinea-pig tests agree with the findings of tests in humans. In addition, the frequencies of false positive and false negative predictive findings are considered and statistically analysed. The results clearly demonstrate the superiority of adjuvant tests (complete Freund's adjuvant) in determining skin sensitizers and the overall superiority of the guinea-pig maximization test in providing results similar to those obtained by human testing. A procedure is suggested for utilizing adjuvant and non-adjuvant test methods for characterizing compounds as of weak, moderate or strong sensitizing potential.

  5. Intraoperative clinical assessment and pressure measurements of sentinel lymph nodes in breast cancer.

    PubMed

    Nathanson, S David; Shah, Rupen; Chitale, Dhananjay A; Mahan, Meredith

    2014-01-01

    Clinicians have long regarded firm enlarged axillary nodes as suspicious for metastasis, and this has been confirmed to represent increased pressure in sentinel lymph nodes (SLN) in vivo in breast cancer. We hypothesized that measuring intranodal pressure (INP) in the operating room would correlate with metastasis size and be more sensitive than clinical observation. Intranodal pressure mmHg was measured in SLNs #1 and #2 (N = 134 and 32) in 122 patients with T1/2 cN0 and 6 controls (T0) (8 bilateral). Clinical "Level of Suspicion" (LOS) was: 0 = benign; 1 = slightly suspicious; 2 = obvious metastasis. Statistical analysis was performed to compare INP, LOS, and SLN metastasis size mm. Sentinel lymph nodes met size correlated with INP (r = 0.65; p < 0.001). INP was 22.0 ± 1.3 mmHg in 35 SLNs with metastases compared with 9.3 ± 0.7 mmHg in 132 without (p < 0.001). Six groups created by combining LOS 0, 1, and 2 with INP >17 or ≤17 mmHg showed a significant (p < 0.001) correlation with SLN histology; sensitivity and specificity for LOS = 2/INP >17 mmHg = 100 % at predicting metastases; LOS = 0/INP ≤17 mmHg most often correct at predicting negative nodes (sensitivity 50 %, specificity 92.9 %, positive predictive value 55 %, negative predictive value 90.7 %). INP was better than LOS at predicting positive nodes in eight patients where INP was >17 mmHg. INP and LOS correlated significantly (p < 0.001). Clinical suspicion of metastasis correlated well with INP particularly at predicting macrometastases. INP was slightly better at predicting micrometastases. Measurement of INP may be valuable adjunct when performing SLN biopsy when further axillary surgery is contemplated.

  6. Skin prick testing predicts peanut challenge outcome in previously allergic or sensitized children with low serum peanut-specific IgE antibody concentration.

    PubMed

    Nolan, Richard C; Richmond, Peter; Prescott, Susan L; Mallon, Dominic F; Gong, Grace; Franzmann, Annkathrin M; Naidoo, Rama; Loh, Richard K S

    2007-05-01

    Peanut allergy is transient in some children but it is not clear whether quantitating peanut-specific IgE by Skin Prick Test (SPT) adds additional information to fluorescent-enzyme immunoassay (FEIA) in discriminating between allergic and tolerant children. To investigate whether SPT with a commercial extract or fresh foods adds additional predictive information for peanut challenge in children with a low FEIA (<10 k UA/L) who were previously sensitized, or allergic to peanuts. Children from a hospital-based allergy service who were previously sensitized or allergic to peanuts were invited to undergo a peanut challenge unless they had a serum peanut-specific IgE>10 k UA/L, a previous severe reaction, or a recent reaction to peanuts (within two years). SPT with a commercial extract, raw and roasted saline soaked peanuts was performed immediately prior to open challenge in hospital with increasing quantity of peanuts until total of 26.7 g of peanut was consumed. A positive challenge consisted of an objective IgE mediated reaction occurring during the observation period. 54 children (median age of 6.3 years) were admitted for a challenge. Nineteen challenges were positive, 27 negative, five were indeterminate and three did not proceed after SPT. Commercial and fresh food extracts provided similar diagnostic information. A wheal diameter of >or=7 mm of the commercial extract predicted an allergic outcome with specificity 97%, positive predictive value 93% and sensitivity 83%. There was a tendency for an increase in SPT wheal since initial diagnosis in children who remained allergic to peanuts while it decreased in those with a negative challenge. The outcome of a peanut challenge in peanut sensitized or previously allergic children with a low FEIA can be predicted by SPT. In this cohort, not challenging children with a SPT wheal of >or=7 mm would have avoided 15 of 18 positive challenges and denied a challenge to one out of 27 tolerant children.

  7. Agreement of histopathological findings of uterine curettage and hysterectomy specimens in women with abnormal uterine bleeding.

    PubMed

    Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita

    2017-05-01

    To examined the diagnostic value of  dilatation and curettage (D and C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D and C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized  in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to  AUB and who had undergone hysterectomy were investigated. The patients' characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D and C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D and C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps.

  8. Agreement of histopathological findings of uterine curettage and hysterectomy specimens in women with abnormal uterine bleeding

    PubMed Central

    Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita

    2017-01-01

    Objectives: To examined the diagnostic value of dilatation and curettage (D&C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D&C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to AUB and who had undergone hysterectomy were investigated. The patients’ characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D&C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D&C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps. PMID:28439599

  9. Psychometric schizotypy predicts psychotic-like, paranoid, and negative symptoms in daily life.

    PubMed

    Barrantes-Vidal, Neus; Chun, Charlotte A; Myin-Germeys, Inez; Kwapil, Thomas R

    2013-11-01

    Positive and negative schizotypy exhibit differential patterns of impairment in social relations, affect, and functioning in daily life. However, studies have not examined the association of schizotypy with real-world expression of psychotic-like, paranoid, and negative symptoms. The present study employed experience-sampling methodology (ESM) to assess positive and negative schizotypy in daily life in a nonclinical sample of 206 Spanish young adults. Participants were prompted randomly 8 times daily for 1 week to complete assessments of their current symptoms and experiences. Positive schizotypy was associated with psychotic-like and paranoid symptoms in daily life. Negative schizotypy was associated with a subset of these symptoms and with negative symptoms in daily life. Momentary stress was associated with psychotic-like and paranoid symptoms, but only for those high in positive schizotypy. Social stress predicted momentary psychotic-like symptoms in both positive and negative schizotypy. Time-lagged analyses indicated that stress at the preceding signal predicted psychotic-like symptoms at the current assessment, but only for individuals high in positive schizotypy. The results are consistent with models linking stress sensitivity with the experience of psychotic symptoms. The findings provide cross-cultural support for the multidimensional model of schizotypy and schizophrenia. Furthermore, the findings demonstrate that ESM is an effective method for predicting the experience of psychotic-like symptoms, as well as their precursors, in daily life. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  10. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia.

    PubMed

    Somily, Ali M; Barry, Mazin A; Habib, Hanan A; Alotaibi, Fawzia E; Al-Zamil, Fahad A; Khan, Mohammed A; Sarwar, Mohammed S; Bakhash, Nawab D; Alrabiaah, Abdulkarim A; Shakoor, Zahid A; Senok, Abiola C

    2016-12-01

    To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results: Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity  and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion: The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens.

  11. Evaluation of GeneXpert MTB/RIF for detection of Mycobacterium tuberculosis complex and rpo B gene in respiratory and non-respiratory clinical specimens at a tertiary care teaching hospital in Saudi Arabia

    PubMed Central

    Somily, Ali M.; Barry, Mazin A.; Habib, Hanan A.; Alotaibi, Fawzia E.; Al-Zamil, Fahad A.; Khan, Mohammed A.; Sarwar, Mohammed S.; Bakhash, Nawab D.; Alrabiaah, Abdulkarim A.; Shakoor, Zahid A.; Senok, Abiola C.

    2016-01-01

    Objectives To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens. PMID:27874159

  12. Development and validation of a parent-report measure for detection of cognitive delay in infancy.

    PubMed

    Schafer, Graham; Genesoni, Lucia; Boden, Greg; Doll, Helen; Jones, Rosamond A K; Gray, Ron; Adams, Eleri; Jefferson, Ros

    2014-12-01

    To develop a brief, parent-completed instrument (ERIC - Early Report by Infant Caregivers) for detection of cognitive delay in 10- to 24-month-olds born preterm, or of low birthweight, or with perinatal complications, and to establish ERIC's diagnostic properties. Scores for ERIC were collected from the parents of 317 children meeting ≥inclusion criterion (birthweight <1500 g, gestational age <34 completed weeks, 5 min Apgar score <7, or presence of hypoxic-ischaemic encephalopathy) and no exclusion criteria. Children were assessed using a criterion score of below 80 on the Bayley Scales of Infant and Toddler Development-III cognitive scale. Items were retained according to their individual associations with delay. Sensitivity, specificity, and positive and negative predictive values were estimated and a truncated ERIC was developed for use in children <14 months old. ERIC correctly detected developmental delay in 17 out of 18 children in the sample, with 94.4% sensitivity, 76.9% specificity, 19.8% positive predictive value, 99.6% negative predictive value, 4.09 likelihood ratio positive, and 0.07 likelihood ratio negative. ERIC has potential value as a quickly administered diagnostic instrument for the absence of early cognitive delay in 10- to 24-month-old preterm infants and as a screen for cognitive delay. © 2014 Mac Keith Press.

  13. Transperineal ultrasound compared to evacuation proctography for diagnosing enteroceles and intussusceptions.

    PubMed

    Weemhoff, M; Kluivers, K B; Govaert, B; Evers, J L H; Kessels, A G H; Baeten, C G

    2013-03-01

    This study concerns the level of agreement between transperineal ultrasound and evacuation proctography for diagnosing enteroceles and intussusceptions. In a prospective observational study, 50 consecutive women who were planned to have an evacuation proctography underwent transperineal ultrasound too. Sensitivity, specificity, positive (PPV) and negative predictive value, as well as the positive and negative likelihood ratio of transperineal ultrasound were assessed in comparison to evacuation proctography. To determine the interobserver agreement of transperineal ultrasound, the quadratic weighted kappa was calculated. Furthermore, receiver operating characteristic curves were generated to show the diagnostic capability of transperineal ultrasound. For diagnosing intussusceptions (PPV 1.00), a positive finding on transperineal ultrasound was predictive of an abnormal evacuation proctography. Sensitivity of transperineal ultrasound was poor for intussusceptions (0.25). For diagnosing enteroceles, the positive likelihood ratio was 2.10 and the negative likelihood ratio, 0.85. There are many false-positive findings of enteroceles on ultrasonography (PPV 0.29). The interobserver agreement of the two ultrasonographers assessed as the quadratic weighted kappa of diagnosing enteroceles was 0.44 and that of diagnosing intussusceptions was 0.23. An intussusception on ultrasound is predictive of an abnormal evacuation proctography. For diagnosing enteroceles, the diagnostic quality of transperineal ultrasound was limited compared to evacuation proctography.

  14. Preoperative Magnetic Resonance Volumetry in Predicting Myometrial Invasion, Lymphovascular Space Invasion, and Tumor Grade: Is It Valuable in International Federation of Gynecology and Obstetrics Stage I Endometrial Cancer?

    PubMed

    Sahin, Hilal; Sarioglu, Fatma Ceren; Bagci, Mustafa; Karadeniz, Tugba; Uluer, Hatice; Sanci, Muzaffer

    2018-05-01

    The aim of this retrospective single-center study was to evaluate the relationship between maximum tumor size, tumor volume, tumor volume ratio (TVR) based on preoperative magnetic resonance (MR) volumetry, and negative histological prognostic parameters (deep myometrial invasion [MI], lymphovascular space invasion, tumor histological grade, and subtype) in International Federation of Gynecology and Obstetrics stage I endometrial cancer. Preoperative pelvic MR imaging studies of 68 women with surgical-pathologic diagnosis of International Federation of Gynecology and Obstetrics stage I endometrial cancer were reviewed for assessment of MR volumetry and qualitative assessment of MI. Volume of the tumor and uterus was measured with manual tracing of each section on sagittal T2-weighted images. Tumor volume ratio was calculated according to the following formula: TVR = (total tumor volume/total uterine volume) × 100. Receiver operating characteristics curve was performed to investigate a threshold for TVR associated with MI. The Mann-Whitney U test, Kruskal-Wallis test, and linear regression analysis were applied to evaluate possible differences between tumor size, tumor volume, TVR, and negative prognostic parameters. Receiver operating characteristics curve analysis of TVR for prediction of deep MI was statistically significant (P = 0.013). An optimal TVR threshold of 7.3% predicted deep myometrial invasion with 85.7% sensitivity, 46.8% specificity, 41.9% positive predictive value, and 88.0% negative predictive value. Receiver operating characteristics curve analyses of TVR, tumor size, and tumor volume for prediction of tumor histological grade or lymphovascular space invasion were not significant. The concordance between radiologic and pathologic assessment for MI was almost excellent (κ value, 0.799; P < 0.001). Addition of TVR to standard radiologic assessment of deep MI increased the sensitivity from 90.5% to 95.2%. Tumor volume ratio, based on preoperative MR volumetry, seems to predict deep MI independently in stage I endometrial cancer with insufficient sensitivity and specificity. Its value in clinical practice for risk stratification models in endometrial cancer has to be studied in larger cohort of patients.

  15. Differentiating the origin of outflow tract ventricular arrhythmia using a simple, novel approach.

    PubMed

    Efimova, Elena; Dinov, Borislav; Acou, Willem-Jan; Schirripa, Valentina; Kornej, Jelena; Kosiuk, Jedrzej; Rolf, Sascha; Sommer, Philipp; Richter, Sergio; Bollmann, Andreas; Hindricks, Gerhard; Arya, Arash

    2015-07-01

    Numerous electrocardiographic (ECG) criteria have been proposed to identify localization of outflow tract ventricular arrhythmias (OT-VAs); however, in some cases, it is difficult to accurately localize the origin of OT-VA using the surface ECG. The purpose of this study was to assess a simple criterion for localization of OT-VAs during electrophysiology study. We measured the interval from the onset of the earliest QRS complex of premature ventricular contractions (PVCs) to the distal right ventricular apical signal (the QRS-RVA interval) in 66 patients (31 men aged 53.3 ± 14.0 years; right ventricular outflow tract [RVOT] origin in 37) referred for ablation of symptomatic outflow tract PVCs. We prospectively validated this criterion in 39 patients (22 men aged 52 ± 15 years; RVOT origin in 19). Compared with patients with RVOT PVCs, the QRS-RVA interval was significantly longer in patients with left ventricular outflow tract (LVOT) PVCs (70 ± 14 vs 33.4±10 ms, P < .001). Receiver operating characteristic analysis showed that a QRS-RVA interval ≥49 ms had sensitivity, specificity, and positive and negative predictive values of 100%, 94.6%, 93.5%, and 100%, respectively, for prediction of an LVOT origin. The same analysis in the validation cohort showed sensitivity, specificity, and positive and negative predictive values of 94.7%, 95%, 95%, and 94.7%, respectively. When these data were combined, a QRS-RVA interval ≥49 ms had sensitivity, specificity, and positive and negative predictive values of 98%, 94.6%, 94.1%, and 98.1%, respectively, for prediction of an LVOT origin. A QRS-RVA interval ≥49 ms suggests an LVOT origin. The QRS-RVA interval is a simple and accurate criterion for differentiating the origin of outflow tract arrhythmia during electrophysiology study; however, the accuracy of this criterion in identifying OT-VA from the right coronary cusp is limited. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Frailty Screening Tools for Elderly Patients Incident to Dialysis.

    PubMed

    van Loon, Ismay N; Goto, Namiko A; Boereboom, Franciscus T J; Bots, Michiel L; Verhaar, Marianne C; Hamaker, Marije E

    2017-09-07

    A geriatric assessment is an appropriate method for identifying frail elderly patients. In CKD, it may contribute to optimize personalized care. However, a geriatric assessment is time consuming. The purpose of our study was to compare easy to apply frailty screening tools with the geriatric assessment in patients eligible for dialysis. A total of 123 patients on incident dialysis ≥65 years old were included <3 weeks before to ≤2 weeks after dialysis initiation, and all underwent a geriatric assessment. Patients with impairment in two or more geriatric domains on the geriatric assessment were considered frail. The diagnostic abilities of six frailty screening tools were compared with the geriatric assessment: the Fried Frailty Index, the Groningen Frailty Indicator, Geriatric8, the Identification of Seniors at Risk, the Hospital Safety Program, and the clinical judgment of the nephrologist. Outcome measures were sensitivity, specificity, positive predictive value, and negative predictive value. In total, 75% of patients were frail according to the geriatric assessment. Sensitivity of frailty screening tools ranged from 48% (Fried Frailty Index) to 88% (Geriatric8). The discriminating features of the clinical judgment were comparable with the other screening tools. The Identification of Seniors at Risk screening tool had the best discriminating abilities, with a sensitivity of 74%, a specificity of 80%, a positive predictive value of 91%, and a negative predictive value of 52%. The negative predictive value was poor for all tools, which means that almost one half of the patients screened as fit (nonfrail) had two or more geriatric impairments on the geriatric assessment. All frailty screening tools are able to detect geriatric impairment in elderly patients eligible for dialysis. However, all applied screening tools, including the judgment of the nephrologist, lack the discriminating abilities to adequately rule out frailty compared with a geriatric assessment. Copyright © 2017 by the American Society of Nephrology.

  17. The effectiveness of breath carbon monoxide analyzer in screening for environmental tobacco smoke exposure in Saudi pregnant women.

    PubMed

    Alzeidan, Rasmieh Ayed; Mandil, Ahmed Amin; Fayed, Amel Ahmed; Wahabi, Hayfaa Abdulmajeed

    2013-10-01

    Exposure to environmental tobacco smoke (ETS) has harmful effects on the pregnancy outcomes similar to those observed in actively smoking pregnant women. The aim of this study was to estimate the sensitivity and specificity of the breath carbon monoxide (BCO) analysis in the assessment of smoking status among Saudi pregnant women, including ETS exposure compared to self-reported tobacco smoke exposure. A cross-sectional design was used during January 2012, 560 pregnant women, irrespective of their gestational age, agreed to undergo BCO testing and completed the data collection sheet for the study. Sensitivity, specificity, positive and negative predictive values were calculated to compare the BCO test with self-reported exposure to ETS. Of the study population 151 (27%) women self-reported ETS exposure during the index pregnancy, 409 (73%) self-reported non-exposure. Sensitivity of the test was 32.5% (95% CI; 25.2-40.3%), the Specificity was much higher at 69.2% (95% CI; 64.4-73.5%), the positive predictive value was 28% (95% CI, 21.9-35.1%), and the negative predictive value was 73.5% (95% CI; 68.9-77.7%). The BCO test is an ineffective tool to detect the level of ETS exposure among Saudi pregnant women.

  18. Evaluation and comparison of statistical methods for early temporal detection of outbreaks: A simulation-based study

    PubMed Central

    Le Strat, Yann

    2017-01-01

    The objective of this paper is to evaluate a panel of statistical algorithms for temporal outbreak detection. Based on a large dataset of simulated weekly surveillance time series, we performed a systematic assessment of 21 statistical algorithms, 19 implemented in the R package surveillance and two other methods. We estimated false positive rate (FPR), probability of detection (POD), probability of detection during the first week, sensitivity, specificity, negative and positive predictive values and F1-measure for each detection method. Then, to identify the factors associated with these performance measures, we ran multivariate Poisson regression models adjusted for the characteristics of the simulated time series (trend, seasonality, dispersion, outbreak sizes, etc.). The FPR ranged from 0.7% to 59.9% and the POD from 43.3% to 88.7%. Some methods had a very high specificity, up to 99.4%, but a low sensitivity. Methods with a high sensitivity (up to 79.5%) had a low specificity. All methods had a high negative predictive value, over 94%, while positive predictive values ranged from 6.5% to 68.4%. Multivariate Poisson regression models showed that performance measures were strongly influenced by the characteristics of time series. Past or current outbreak size and duration strongly influenced detection performances. PMID:28715489

  19. Diagnostic inaccuracy of smartphone applications for melanoma detection.

    PubMed

    Wolf, Joel A; Moreau, Jacqueline F; Akilov, Oleg; Patton, Timothy; English, Joseph C; Ho, Jonhan; Ferris, Laura K

    2013-04-01

    To measure the performance of smartphone applications that evaluate photographs of skin lesions and provide the user with feedback about the likelihood of malignancy. Case-control diagnostic accuracy study. Academic dermatology department. PARTICIPANTS AND MATERIALS: Digital clinical images of pigmented cutaneous lesions (60 melanoma and 128 benign control lesions) with a histologic diagnosis rendered by a board-certified dermatopathologist, obtained before biopsy from patients undergoing lesion removal as a part of routine care. Sensitivity, specificity, and positive and negative predictive values of 4 smartphone applications designed to aid nonclinician users in determining whether their skin lesion is benign or malignant. Sensitivity of the 4 tested applications ranged from 6.8% to 98.1%; specificity, 30.4% to 93.7%; positive predictive value, 33.3% to 42.1%; and negative predictive value, 65.4% to 97.0%. The highest sensitivity for melanoma diagnosis was observed for an application that sends the image directly to a board-certified dermatologist for analysis; the lowest, for applications that use automated algorithms to analyze images. The performance of smartphone applications in assessing melanoma risk is highly variable, and 3 of 4 smartphone applications incorrectly classified 30% or more of melanomas as unconcerning. Reliance on these applications, which are not subject to regulatory oversight, in lieu of medical consultation can delay the diagnosis of melanoma and harm users.

  20. The influence of structural stigma and rejection sensitivity on young sexual minority men's daily tobacco and alcohol use

    PubMed Central

    Pachankis, John E.; Hatzenbuehler, Mark L.; Starks, Tyrel J.

    2018-01-01

    Stigma occurs at both individual and structural levels, but existing research tends to examine the effect of individual and structural forms of stigma in isolation, rather than considering potential synergistic effects. To address this gap, our study examined whether stigma at the individual level, namely gay-related rejection sensitivity, interacts with structural stigma to predict substance use among young sexual minority men. Sexual minority (n = 119) participants completed online measures of our constructs (e.g., rejection sensitivity). Participants currently resided across a broad array of geographic areas (i.e., 24 U.S. states), and had attended high school in 28 states, allowing us to capture sufficient variance in current and past forms of structural stigma, defined as (1) a lack of state-level policies providing equal opportunities for heterosexual and sexual minority individuals and (2) negative state-aggregated attitudes toward sexual minorities. To measure daily substance use, we utilized a daily diary approach, whereby all participants were asked to indicate whether they used tobacco or alcohol on nine consecutive days. Results indicated that structural stigma interacted with rejection sensitivity to predict tobacco and alcohol use, and that this relationship depended on the developmental timing of exposure to structural stigma. In contrast, rejection sensitivity did not mediate the relationship between structural stigma and substance use. These results suggest that psychological predispositions, such as rejection sensitivity, interact with features of the social environment, such as structural stigma, to predict important health behaviors among young sexual minority men. These results add to a growing body of research documenting the multiple levels through which stigma interacts to produce negative health outcomes among sexual minority individuals. PMID:24507912

  1. Determination of IgE antibodies to the benzylpenicilloyl determinant: a comparison of the sensitivity and specificity of three radio allergo sorbent test methods.

    PubMed

    Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E

    1997-01-01

    The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.

  2. Evaluation of the Predictive Validity of Thermography in Identifying Extravasation With Intravenous Chemotherapy Infusions.

    PubMed

    Matsui, Yuko; Murayama, Ryoko; Tanabe, Hidenori; Oe, Makoto; Motoo, Yoshiharu; Wagatsuma, Takanori; Michibuchi, Michiko; Kinoshita, Sachiko; Sakai, Keiko; Konya, Chizuko; Sugama, Junko; Sanada, Hiromi

    Early detection of extravasation is important, but conventional methods of detection lack objectivity and reliability. This study evaluated the predictive validity of thermography for identifying extravasation during intravenous antineoplastic therapy. Of 257 patients who received chemotherapy through peripheral veins, extravasation was identified in 26. Thermography was performed every 15 to 30 minutes during the infusions. Sensitivity, specificity, positive predictive value, and negative predictive value using thermography were 84.6%, 94.8%, 64.7%, and 98.2%, respectively. This study showed that thermography offers an accurate prediction of extravasation.

  3. Risk management and precaution: insights on the cautious use of evidence.

    PubMed Central

    Hrudey, Steve E; Leiss, William

    2003-01-01

    Risk management, done well, should be inherently precautionary. Adopting an appropriate degree of precaution with respect to feared health and environmental hazards is fundamental to risk management. The real problem is in deciding how precautionary to be in the face of inevitable uncertainties, demanding that we understand the equally inevitable false positives and false negatives from screening evidence. We consider a framework for detection and judgment of evidence of well-characterized hazards, using the concepts of sensitivity, specificity, positive predictive value, and negative predictive value that are well established for medical diagnosis. Our confidence in predicting the likelihood of a true danger inevitably will be poor for rare hazards because of the predominance of false positives; failing to detect a true danger is less likely because false negatives must be rarer than the danger itself. Because most controversial environmental hazards arise infrequently, this truth poses a dilemma for risk management. PMID:14527835

  4. Political Orientation Predicts Credulity Regarding Putative Hazards.

    PubMed

    Fessler, Daniel M T; Pisor, Anne C; Holbrook, Colin

    2017-05-01

    To benefit from information provided by other people, people must be somewhat credulous. However, credulity entails risks. The optimal level of credulity depends on the relative costs of believing misinformation and failing to attend to accurate information. When information concerns hazards, erroneous incredulity is often more costly than erroneous credulity, given that disregarding accurate warnings is more harmful than adopting unnecessary precautions. Because no equivalent asymmetry exists for information concerning benefits, people should generally be more credulous of hazard information than of benefit information. This adaptive negatively biased credulity is linked to negativity bias in general and is more prominent among people who believe the world to be more dangerous. Because both threat sensitivity and beliefs about the dangerousness of the world differ between conservatives and liberals, we predicted that conservatism would positively correlate with negatively biased credulity. Two online studies of Americans supported this prediction, potentially illuminating how politicians' alarmist claims affect different portions of the electorate.

  5. Diffusion-Weighted Magnetic Resonance Imaging of Cholesteatoma Using PROPELLER at 1.5T: A Single-Centre Retrospective Study.

    PubMed

    Clarke, Sharon E; Mistry, Dipan; AlThubaiti, Talal; Khan, M Naeem; Morris, David; Bance, Manohar

    2017-05-01

    The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Validity of Teacher-Based Vision Screening and Factors Associated with the Accuracy of Vision Screening in Vietnamese Children.

    PubMed

    Paudel, Prakash; Kovai, Vilas; Naduvilath, Thomas; Phuong, Ha Thanh; Ho, Suit May; Giap, Nguyen Viet

    2016-01-01

    To assess validity of teacher-based vision screening and elicit factors associated with accuracy of vision screening in Vietnam. After brief training, teachers independently measured visual acuity (VA) in 555 children aged 12-15 years in Ba Ria - Vung Tau Province. Teacher VA measurements were compared to those of refractionists. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for uncorrected VA (UVA) and presenting VA (PVA) 20/40 or worse in either eye. Chi-square, Fisher's exact test and multivariate logistic regression were used to assess factors associated with accuracy of vision screening. Level of significance was set at 5%. Trained teachers in Vietnam demonstrated 86.7% sensitivity, 95.7% specificity, 86.7% positive predictive value and 95.7% negative predictive value in identifying children with visual impairment using the UVA measurement. PVA measurement revealed low accuracy for teachers, which was significantly associated with child's age, sex, spectacle wear and myopic status, but UVA measurement showed no such associations. Better accuracy was achieved in measurement of VA and identification of children with visual impairment using UVA measurement compared to PVA. UVA measurement is recommended for teacher-based vision screening programs.

  7. Traumatic Brain Injury in Children: Role of CDRs-PECARN as a Clinical Predictive Resource for Evaluation of Intracranical Lesions and Neuropsychiatric Outcomes.

    PubMed

    Ferrara, Pietro; Basile, Maria Cristina; Dell'Aquila, Livia; Vena, Flaminia; Coppo, Elena; Chiaretti, Antonio; Verrotti, Alberto; Paolini, Fabrizio; Caldarelli, Massimo

    2016-01-01

    Cranial computed tomography (CT) is considered the gold standard for the diagnosis of traumatic brain injury (TBI). The aim of this study was to evaluate if the clinical decision rules proposed by the Pediatric Emergency Care Applied Research Network (CDRs-PECARN) are really able to identify the patients who do not need cranial CT. This study investigates the neuropsychiatric outcome after TBI according to a pediatric version of the Glasgow Outcome Scale-Extended (GOS-E Peds). We calculated the sensitivity, specificity, negative predictive value (NPV) and positive predictive value of the CDRs-PECARN in 2 age groups. Sensitivity was very high in both groups, and the NPV was very useful for predicting which subjects, of those who presented without CDRs- PECARN, would have a negative cranial CT. We also evaluated the correlations between the GOS-E Peds and Glasgow Coma Scale and between the GOS-E Peds and cranial CT scan. Our study confirms the validation of the PECARN TBI prediction rules as a clinical instrument which can play a significant role in CT decision-making for children with TBI. It also demonstrates that the GOS-E Peds is a valid pediatric outcome scale for children with TBI, despite some important limitations. © 2016 S. Karger AG, Basel.

  8. [Waist-to-height ratio is an indicator of metabolic risk in children].

    PubMed

    Valle-Leal, Jaime; Abundis-Castro, Leticia; Hernández-Escareño, Juan; Flores-Rubio, Salvador

    2016-01-01

    Abdominal fat, particularly visceral, is associated with a high risk of metabolic complications. The waist-height ratio (WHtR) is used to assess abdominal fat in individuals of all ages. To determine the ability of the waist-to-height ratio to detect metabolic risk in mexican schoolchildren. A study was conducted on children between 6 and 12 years. Obesity was diagnosed as a body mass index (BMI) ≥ 85th percentile, and an ICE ≥0.5 was considered abdominal obesity. Blood levels of glucose, cholesterol and triglycerides were measured. The sensitivity, specificity, positive predictive and negative value, area under curve, the positive likelihood ratio and negative likelihood ratio of the WHtR and BMI were calculated in order to identify metabolic alterations. WHtR and BMI were compared to determine which had the best diagnostic efficiency. Of the 223 children included in the study, 51 had hypertriglyceridaemia, 27 with hypercholesterolaemia, and 9 with hyperglycaemia. On comparing the diagnostic efficiency of WHtR with that of BMI, there was a sensitivity of 100% vs. 56% for hyperglycaemia, 93 vs. 70% for cholesterol, and 76 vs. 59% for hypertriglyceridaemia. The specificity, negative predictive value, positive predictive value, positive likelihood ratio, negative likelihood ratio, and area under curve were also higher for WHtR. The WHtR is a more efficient indicator than BMI in identifying metabolic risk in mexican school-age. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Evaluation of brush cytology and DNA image cytometry for the detection of cancer of the oral cavity.

    PubMed

    Kaur, Manveen; Handa, Uma; Mohan, Harsh; Dass, Arjun

    2016-03-01

    Cancer of the oral cavity is the sixth most common malignancy reported worldwide. This study was undertaken to evaluate the efficacy of brush cytology and the adjunctive role of DNA image cytometry (ICM) in the diagnosis of oral cancer. Oral brush smears and biopsy were obtained from 100 consecutive patients presenting with suspicious oral lesions. DNA-ICM was performed on 96 cytology smears which had adequate cellularity. On cytology, 54 cases were benign, 36 were malignant, 6 were suspicious for malignancy, and 4 were inadequate due to scanty cellularity. On histopathologic examination, 49 cases were diagnosed as squamous cell carcinoma and 51 cases as benign. The sensitivity of brush cytology for the detection of cancer was 83.3% and the specificity was 95.8%. The positive and negative predictive values were 95.2% and 85.2%, respectively, with a diagnostic accuracy of 86%. Out of 96 cases analyzed by image analysis to assess DNA ploidy, 33 cases were aneuploid and 63 were diploid. The sensitivity, specificity, positive predictive value, and negative predictive value of DNA-ICM were 68.7%, 100%, 100%, and 76.1%, respectively, giving a diagnostic accuracy of 81%. The combination of cytology and DNA cytometry increased the sensitivity to 92% and specificity to 100%. The study demonstrates the usefulness of DNA-ICM as an adjunct to brush cytology to diagnose oral cancer. It reduces the false negative cases on cytology and also adds to objectivity in cytologically doubtful cases. © 2016 Wiley Periodicals, Inc.

  10. Assessing the psychometric properties of two food addiction scales.

    PubMed

    Lemeshow, Adina R; Gearhardt, Ashley N; Genkinger, Jeanine M; Corbin, William R

    2016-12-01

    While food addiction is well accepted in popular culture and mainstream media, its scientific validity as an addictive behavior is still under investigation. This study evaluated the reliability and validity of the Yale Food Addiction Scale and Modified Yale Food Addiction Scale using data from two community-based convenience samples. We assessed the internal and test-retest reliability of the Yale Food Addiction Scale and Modified Yale Food Addiction Scale, and estimated the sensitivity and negative predictive value of the Modified Yale Food Addiction Scale using the Yale Food Addiction Scale as the benchmark. We calculated Cronbach's alphas and 95% confidence intervals (CIs) for internal reliability and Cohen's Kappa coefficients and 95% CIs for test-retest reliability. Internal consistency (n=232) was marginal to good, ranging from α=0.63 to 0.84. The test-retest reliability (n=45) for food addiction diagnosis was substantial, with Kappa=0.73 (95% CI, 0.48-0.88) (Yale Food Addiction Scale) and 0.79 (95% CI, 0.66-1.00) (Modified Yale Food Addiction Scale). Sensitivity and negative predictive value for classifying food addiction status were excellent: compared to the Yale Food Addiction Scale, the Modified Yale Food Addiction Scale's sensitivity was 92.3% (95% CI, 64%-99.8%), and the negative predictive value was 99.5% (95% CI, 97.5%-100%). Our analyses suggest that the Modified Yale Food Addiction Scale may be an appropriate substitute for the Yale Food Addiction Scale when a brief measure is needed, and support the continued use of both scales to investigate food addiction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Diagnostic Accuracy of the Berlin Questionnaire in Detecting Sleep-Disordered Breathing in Patients With a Recent Myocardial Infarction

    PubMed Central

    Sert Kuniyoshi, Fatima H.; Zellmer, Mark R.; Calvin, Andrew D.; Lopez-Jimenez, Francisco; Albuquerque, Felipe N.; van der Walt, Christelle; Trombetta, Ivani C; Caples, Sean M.; Shamsuzzaman, Abu S.; Bukartyk, Jan; Konecny, Tomas; Gami, Apoor S.; Kara, Tomas

    2011-01-01

    Background: The Berlin Questionnaire (BQ) has been used to identify patients at high risk for sleep-disordered breathing (SDB) in a variety of populations. However, there are no data regarding the validity of the BQ in detecting the presence of SDB in patients after myocardial infarction (MI). The aim of this study was to determine the performance of the BQ in patients after MI. Methods: We conducted a cross-sectional study of 99 patients who had an MI 1 to 3 months previously. The BQ was administered, scored using the published methods, and followed by completed overnight polysomnography as the “gold standard.” SDB was defined as an apnea-hypopnea index of ≥ 5 events/h. The sensitivity, specificity, and positive and negative predictive values of the BQ were calculated. Results: Of the 99 patients, the BQ identified 64 (65%) as being at high-risk for having SDB. Overnight polysomnography showed that 73 (73%) had SDB. The BQ sensitivity and specificity was 0.68 and 0.34, respectively, with a positive predictive value of 0.68 and a negative predictive value of 0.50. Positive and negative likelihood ratios were 1.27 and 0.68, respectively, and the BQ overall diagnostic accuracy was 63%. Using different apnea-hypopnea index cutoff values did not meaningfully alter these results. Conclusion: The BQ performed with modest sensitivity, but the specificity was poor, suggesting that the BQ is not ideal in identifying SDB in patients with a recent MI. PMID:21596794

  12. Range position and climate sensitivity: The structure of among-population demographic responses to climatic variation

    USGS Publications Warehouse

    Amburgey, Staci M.; Miller, David A. W.; Grant, Evan H. Campbell; Rittenhouse, Tracy A. G.; Benard, Michael F.; Richardson, Jonathan L.; Urban, Mark C.; Hughson, Ward; Brand, Adrianne B,; Davis, Christopher J.; Hardin, Carmen R.; Paton, Peter W. C.; Raithel, Christopher J.; Relyea, Rick A.; Scott, A. Floyd; Skelly, David K.; Skidds, Dennis E.; Smith, Charles K.; Werner, Earl E.

    2018-01-01

    Species’ distributions will respond to climate change based on the relationship between local demographic processes and climate and how this relationship varies based on range position. A rarely tested demographic prediction is that populations at the extremes of a species’ climate envelope (e.g., populations in areas with the highest mean annual temperature) will be most sensitive to local shifts in climate (i.e., warming). We tested this prediction using a dynamic species distribution model linking demographic rates to variation in temperature and precipitation for wood frogs (Lithobates sylvaticus) in North America. Using long-term monitoring data from 746 populations in 27 study areas, we determined how climatic variation affected population growth rates and how these relationships varied with respect to long-term climate. Some models supported the predicted pattern, with negative effects of extreme summer temperatures in hotter areas and positive effects on recruitment for summer water availability in drier areas. We also found evidence of interacting temperature and precipitation influencing population size, such as extreme heat having less of a negative effect in wetter areas. Other results were contrary to predictions, such as positive effects of summer water availability in wetter parts of the range and positive responses to winter warming especially in milder areas. In general, we found wood frogs were more sensitive to changes in temperature or temperature interacting with precipitation than to changes in precipitation alone. Our results suggest that sensitivity to changes in climate cannot be predicted simply by knowing locations within the species’ climate envelope. Many climate processes did not affect population growth rates in the predicted direction based on range position. Processes such as species-interactions, local adaptation, and interactions with the physical landscape likely affect the responses we observed. Our work highlights the need to measure demographic responses to changing climate.

  13. Role of specimen US for predicting resection margin status in breast conserving therapy

    PubMed Central

    MOSCHETTA, M.; TELEGRAFO, M.; INTRONA, T.; COI, L.; RELLA, L.; RANIERI, V.; CIRILLI, A.; IANORA, A.A. STABILE; ANGELELLI, G.

    2015-01-01

    Aim To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. Patients and methods A total of 132 consecutive patients (age range, 34–87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. Results The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Conclusions Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status. PMID:26712255

  14. Predictive Capability of an iPad-Based Medical Device (medx) for the Diagnosis of Vertigo and Dizziness.

    PubMed

    Feil, Katharina; Feuerecker, Regina; Goldschagg, Nicolina; Strobl, Ralf; Brandt, Thomas; von Müller, Albrecht; Grill, Eva; Strupp, Michael

    2018-01-01

    Making the correct diagnosis of patients presenting with vertigo and dizziness in clinical practice is often challenging. In this study we examined the performance of the iPad based program me d x in the prediction of different clinical vertigo and dizziness diagnoses and as a diagnostic tool to distinguish between them. The data collection was done in the outpatient clinic of the German Center of Vertigo and Balance Disorders. The "gold standard diagnosis" was defined as the clinical diagnosis of the specialist during the visit of the patient based on standardized history and clinical examination. Another independent and blinded physician finalized each patient's case in the constellatory diagnostic system of me d x based on an algorithm using all available clinical information. These diagnoses were compared to the "gold standard" by retrospective review of the charts of the patients. The accuracy provided by me d x was defined as the number of correctly classified diagnoses. In addition, the probability of being test positive when a disease was present (sensitivity), of being test negative when a disease was absent (specificity), of having the disease when the test is positive (positive predictive value) and of not having the disease when the test is negative (negative predictive value) for the most common diagnoses were reported. Sixteen possible different vertigo and dizziness diagnoses could be provided by me d x. A total of 610 patients (mean age 58.1 ± 16.3 years, 51.2% female) were included. The accuracy for the most common diagnoses was between 82.1 and 96.6% with a sensitivity of 40 to 80.5% and a specificity of more than 80%. When analyzing the quality of me d x in a multiclass problem for the six most common clinical diagnoses, the sensitivity, specificity, positive and negative predictive values were as follows: Bilateral vestibulopathy (81.6, 97.1, 71.1, and 97.5%), Menière's disease (77.8, 97.6, 87.0, and 95.3%), benign paroxysmal positional vertigo (61.7, 98.3, 86.6, and 93.4%), downbeat nystagmus syndrome (69.6, 97.7, 71.1, and 97.5%), vestibular migraine (34.7, 97.8, 76.1, and 88.3%), and phobic postural vertigo (80.5, 82.5, 52.5, and 94.6%). This study demonstrates that me d x is a new and easy approach to screen for different diagnoses. With the high specificity and negative predictive value, the system helps to rule out differential diagnoses and can therefore also lead to a cost reduction in the health care system. However, the sensitivity was unexpectedly low, especially for vestibular migraine. All in all, this device can only be a complementary tool, in particular for non-experts in the field.

  15. High-Sensitivity Cardiac Troponin and the Risk Stratification of Patients With Renal Impairment Presenting With Suspected Acute Coronary Syndrome

    PubMed Central

    Miller-Hodges, Eve; Anand, Atul; Shah, Anoop S.V.; Chapman, Andrew R.; Gallacher, Peter; Lee, Kuan Ken; Farrah, Tariq; Halbesma, Nynke; Blackmur, James P.; Newby, David E.; Mills, Nicholas L.

    2018-01-01

    Background: High-sensitivity cardiac troponin testing may improve the risk stratification and diagnosis of myocardial infarction, but concentrations can be challenging to interpret in patients with renal impairment, and the effectiveness of testing in this group is uncertain. Methods: In a prospective multicenter study of consecutive patients with suspected acute coronary syndrome, we evaluated the performance of high-sensitivity cardiac troponin I in those with and without renal impairment (estimated glomerular filtration rate <60mL/min/1.73m2). The negative predictive value and sensitivity of troponin concentrations below the risk stratification threshold (5 ng/L) at presentation were reported for a primary outcome of index type 1 myocardial infarction, or type 1 myocardial infarction or cardiac death at 30 days. The positive predictive value and specificity at the 99th centile diagnostic threshold (16 ng/L in women, 34 ng/L in men) was determined for index type 1 myocardial infarction. Subsequent type 1 myocardial infarction and cardiac death were reported at 1 year. Results: Of 4726 patients identified, 904 (19%) had renal impairment. Troponin concentrations <5 ng/L at presentation identified 17% of patients with renal impairment as low risk for the primary outcome (negative predictive value, 98.4%; 95% confidence interval [CI], 96.0%–99.7%; sensitivity 98.9%; 95%CI, 97.5%–99.9%), in comparison with 56% without renal impairment (P<0.001) with similar performance (negative predictive value, 99.7%; 95% CI, 99.4%–99.9%; sensitivity 98.4%; 95% CI, 97.2%–99.4%). The positive predictive value and specificity at the 99th centile were lower in patients with renal impairment at 50.0% (95% CI, 45.2%–54.8%) and 70.9% (95% CI, 67.5%–74.2%), respectively, in comparison with 62.4% (95% CI, 58.8%–65.9%) and 92.1% (95% CI, 91.2%–93.0%) in those without. At 1 year, patients with troponin concentrations >99th centile and renal impairment were at greater risk of subsequent myocardial infarction or cardiac death than those with normal renal function (24% versus 10%; adjusted hazard ratio, 2.19; 95% CI, 1.54–3.11). Conclusions: In suspected acute coronary syndrome, high-sensitivity cardiac troponin identified fewer patients with renal impairment as low risk and more as high risk, but with lower specificity for type 1 myocardial infarction. Irrespective of diagnosis, patients with renal impairment and elevated cardiac troponin concentrations had a 2-fold greater risk of a major cardiac event than those with normal renal function, and should be considered for further investigation and treatment. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01852123. PMID:28978551

  16. Neural reward and punishment sensitivity in cigarette smokers.

    PubMed

    Potts, Geoffrey F; Bloom, Erika L; Evans, David E; Drobes, David J

    2014-11-01

    Nicotine addiction remains a major public health problem but the neural substrates of addictive behavior remain unknown. One characteristic of smoking behavior is impulsive choice, selecting the immediate reward of smoking despite the potential long-term negative consequences. This suggests that drug users, including cigarette smokers, may be more sensitive to rewards and less sensitive to punishment. We used event-related potentials (ERPs) to test the hypothesis that smokers are more responsive to reward signals and less responsive to punishment, potentially predisposing them to risky behavior. We conducted two experiments, one using a reward prediction design to elicit a Medial Frontal Negativity (MFN) and one using a reward- and punishment-motivated flanker task to elicit an Error Related Negativity (ERN), ERP components thought to index activity in the cortical projection of the dopaminergic reward system. The smokers had a greater MFN response to unpredicted rewards, and non-smokers, but not smokers, had a larger ERN on punishment motivated trials indicating that smokers are more reward sensitive and less punishment sensitive than nonsmokers, overestimating the appetitive value and underestimating aversive outcomes of stimuli and actions. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. [Evaluation of T-SPOT.TB assay in the diagnosis of pulmonary tuberculosis within different age groups].

    PubMed

    Pan, Liping; Jia, Hongyan; Liu, Fei; Gao, Mengqiu; Sun, Huishan; Du, Boping; Sun, Qi; Xing, Aiying; Wei, Rongrong; Zhang, Zongde

    2015-12-01

    To evaluate the value of T-SPOT.TB assay in the diagnosis of pulmonary tuberculosis within different age groups. We analyzed 1 518 suspected pulmonary tuberculosis (PTB) patients who were admitted to the Beijing Chest Hospital from November 2012 to February 2014 and had valid T-SPOT.TB tests before anti-tuberculosis therapy. The 599 microbiologically and/or histopathologically-confirmed PTB patients (16-89 years old, 388 males and 211 females) and 235 non-TB patients (14-85 years old, 144 males and 91 females) were enrolled for the analysis of diagnostic performance of T-SPOT.TB, while patients with uncertain diagnosis or diagnosis based on clinical impression (n=684) were excluded from the analysis. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB were analyzed according to the final diagnosis. Furthermore, the diagnostic performance of T-SPOT.TB assay in the younger patients (14-59 years old) and elderly patients (60-89 years old) were also analyzed respectively. Categorical variables were compared by Pearson's Chi-square test, while continuous variables were compared by the Mann-Whitney U-test. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB in diagnosis of PTB were 90.1% (540/599), 65.5% (154/235), 86.9% (540/621), 72.3% (154/213), 2.61, and 0.15, respectively. The sensitivity and specificity of T-SPOT.TB assay were 92.6% (375/405) and 75.6% (99/131), respectively in the younger patients, and 85.0% (165/194), 52.9% (55/104) respectively in the elderly patients. The sensitivity and specificity of T-SPOT.TB assay in the younger patients were significantly higher than those in the elderly patients (P<0.01), and the spot forming cells in the younger PTB patients were significantly higher than in the elderly PTB patients [300 (126, 666)/10(6) PBMCs vs. 258 (79, 621)/10(6) PBMCs, P=0.037]. T-SPOT.TB is a promising test in the diagnosis of younger patients (14-59 years old) with suspected PTB, but the diagnostic performance in elderly patients (60-89 years old) is relatively reduced.

  18. A direct comparison of decision rules for early discharge of suspected acute coronary syndromes in the era of high sensitivity troponin.

    PubMed

    Chew, Pei Gee; Frost, Fredrick; Mullen, Liam; Fisher, Michael; Zadeh, Heidar; Grainger, Ruth; Albouaini, Khaled; Dodd, James; Patel, Bilal; Velavan, Periaswamy; Kunadian, Babu; Rawat, Anju; Obafemi, Toba; Tong, Sarah; Jones, Julia; Khand, Aleem

    2018-02-01

    We tested the hypothesis that a single high sensitivity troponin at limits of detection (LOD HSTnT) (<5 ng/l) combined with a presentation non-ischaemic electrocardiogram is superior to low-risk Global Registry of Acute Coronary Events (GRACE) (<75), Thrombolysis in Myocardial Infarction (TIMI) (≤1) and History, ECG, Age, Risk factors and Troponin (HEART) score (≤3) as an aid to early, safe discharge for suspected acute coronary syndrome. In a prospective cohort study, risk scores were computed in consecutive patients with suspected acute coronary syndrome presenting to the Emergency Room of a large English hospital. Adjudication of myocardial infarction, as per third universal definition, involved a two-physician, blinded, independent review of all biomarker positive chest pain re-presentations to any national hospital. The primary and secondary outcome was a composite of type 1 myocardial infarction, unplanned coronary revascularisation and all cause death (MACE) at six weeks and one year. Of 3054 consecutive presentations with chest pain 1642 had suspected acute coronary syndrome (52% male, median age 59 years, 14% diabetic, 20% previous myocardial infarction). Median time from chest pain to presentation was 9.7 h. Re-presentations occurred in eight hospitals with 100% follow-up achieved. Two hundred and eleven (12.9%) and 279 (17%) were adjudicated to suffer MACE at six weeks and one year respectively. Only HEART ≤3 (negative predictive value MACE 99.4%, sensitivity 97.6%, %discharge 53.4) and LOD HSTnT strategy (negative predictive value MACE 99.8%, sensitivity 99.5%, %discharge 36.9) achieved pre-specified negative predictive value of >99% for MACE at six weeks. For type 1 myocardial infarction alone the negative predictive values at six weeks and one year were identical, for both HEART ≤3 and LOD HSTnT at 99.8% and 99.5% respectively. HEART ≤3 or LOD HSTnT strategy rules out short and medium term myocardial infarction with ≥99.5% certainty, and short-term MACE with >99% certainty, allowing for early discharge of 53.4% and 36.9% respectively of suspected acute coronary syndrome. Adoption of either strategy has the potential to greatly reduce Emergency Room pressures and minimise follow-up investigations. Very early presenters (<3 h), due to limited numbers, are excluded from these conclusions.

  19. Evaluation of a fecal immunochemistry test prior to colonoscopy for outpatients with various indications.

    PubMed

    Szilagyi, Andrew; Xue, Xiaoqing

    2017-01-01

    Stool tests can predict advanced neoplasms prior to colonoscopy. Results of immunochemical stool tests to predict findings at colonoscopy for various indications are less often reported. We compared pre-colonoscopy stool tests with findings in patients undergoing colonoscopy for different indications. Charts of patients undergoing elective or semi-urgent colonoscopy were reviewed. Comparison of adenoma detection rates and pathological findings was made between prescreened and non-prescreened, and between stool-positive and stool-negative cases. Demographics, quality of colonoscopy, and pathological findings were recorded. Odds ratios (ORs) and 95% confidence intervals (CIs) were assessed. Statistical significance was accepted at p ≤0.05. Charts of 325 patients were reviewed. Among them, stool tests were done on 144 patients: 114 were negative and 30 were positive. Findings were similar in the pretest and non-pretest groups. Detection of advanced adenomas per patient was higher in the stool-positive group compared to the stool-negative group (23.4% vs 3.5%, p =0.0016, OR =7.6 [95% CI: 2-29.3]). Five advanced adenomas (without high-grade dysplasia or adenocarcinoma) and several cases of multiple adenomas were missed in the negative group. Sensitivity and specificity for advanced polyps was 63.6% and 82.7%, respectively. The negative predictive value was 96.5%. Male gender was independently predictive of any adenoma. The stool immunochemical test best predicted advanced neoplasms and had a high negative predictive value in this small cohort. Whether this test can be applied to determine the need for colonoscopy in groups other than average risk would require more studies.

  20. Stuttering Thoughts: Negative Self-Referent Thinking Is Less Sensitive to Aversive Outcomes in People with Higher Levels of Depressive Symptoms

    PubMed Central

    Iijima, Yudai; Takano, Keisuke; Boddez, Yannick; Raes, Filip; Tanno, Yoshihiko

    2017-01-01

    Learning theories of depression have proposed that depressive cognitions, such as negative thoughts with reference to oneself, can develop through a reinforcement learning mechanism. This negative self-reference is considered to be positively reinforced by rewarding experiences such as genuine support from others after negative self-disclosure, and negatively reinforced by avoidance of potential aversive situations. The learning account additionally predicts that negative self-reference would be maintained by an inability to adjust one’s behavior when negative self-reference no longer leads to such reward. To test this prediction, we designed an adapted version of the reversal-learning task. In this task, participants were reinforced to choose and engage in either negative or positive self-reference by probabilistic economic reward and punishment. Although participants were initially trained to choose negative self-reference, the stimulus-reward contingencies were reversed to prompt a shift toward positive self-reference (Study 1) and a further shift toward negative self-reference (Study 2). Model-based computational analyses showed that depressive symptoms were associated with a low learning rate of negative self-reference, indicating a high level of reward expectancy for negative self-reference even after the contingency reversal. Furthermore, the difficulty in updating outcome predictions of negative self-reference was significantly associated with the extent to which one possesses negative self-images. These results suggest that difficulty in adjusting action-outcome estimates for negative self-reference increases the chance to be faced with negative aspects of self, which may result in depressive symptoms. PMID:28824511

  1. Stuttering Thoughts: Negative Self-Referent Thinking Is Less Sensitive to Aversive Outcomes in People with Higher Levels of Depressive Symptoms.

    PubMed

    Iijima, Yudai; Takano, Keisuke; Boddez, Yannick; Raes, Filip; Tanno, Yoshihiko

    2017-01-01

    Learning theories of depression have proposed that depressive cognitions, such as negative thoughts with reference to oneself, can develop through a reinforcement learning mechanism. This negative self-reference is considered to be positively reinforced by rewarding experiences such as genuine support from others after negative self-disclosure, and negatively reinforced by avoidance of potential aversive situations. The learning account additionally predicts that negative self-reference would be maintained by an inability to adjust one's behavior when negative self-reference no longer leads to such reward. To test this prediction, we designed an adapted version of the reversal-learning task. In this task, participants were reinforced to choose and engage in either negative or positive self-reference by probabilistic economic reward and punishment. Although participants were initially trained to choose negative self-reference, the stimulus-reward contingencies were reversed to prompt a shift toward positive self-reference (Study 1) and a further shift toward negative self-reference (Study 2). Model-based computational analyses showed that depressive symptoms were associated with a low learning rate of negative self-reference, indicating a high level of reward expectancy for negative self-reference even after the contingency reversal. Furthermore, the difficulty in updating outcome predictions of negative self-reference was significantly associated with the extent to which one possesses negative self-images. These results suggest that difficulty in adjusting action-outcome estimates for negative self-reference increases the chance to be faced with negative aspects of self, which may result in depressive symptoms.

  2. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    PubMed

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  3. Fear of food prospectively predicts drive for thinness in an eating disorder sample recently discharged from intensive treatment.

    PubMed

    Levinson, Cheri A; Brosof, Leigh C; Ma, Jackie; Fewell, Laura; Lenze, Eric J

    2017-12-01

    Fears of food are common in individuals with eating disorders and contribute to the high relapse rates. However, it is unknown how fears of food contribute to eating disorder symptoms across time, potentially contributing to an increased likelihood of relapse. Participants diagnosed with an eating disorder (N=168) who had recently completed intensive treatment were assessed after discharge and one month later regarding fear of food, eating disorder symptoms, anxiety sensitivity, and negative affect. Cross lagged path analysis was utilized to determine if fear of food predicted subsequent eating disorder symptoms one month later. Fear of food-specifically, anxiety about eating and feared concerns about eating-predicted drive for thinness, a core symptom domain of eating disorders. These relationships held while accounting for anxiety sensitivity and negative affect. There is a specific, direct relationship between anxiety about eating and feared concerns about eating and drive for thinness. Future research should test if interventions designed to target fear of food can decrease drive for thinness and thereby prevent relapse. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Diagnostic Inaccuracy of Smart Phone Applications for Melanoma Detection

    PubMed Central

    Wolf, Joel; Moreau, Jacqui; Akilov, Oleg; Patton, Timothy; English, Joseph C; Ho, Jon; Ferris, Laura Korb

    2013-01-01

    Objective To measure the performance of smart phone applications which evaluate photographs of skin lesions and provide the user feedback as to their likelihood of malignancy. Design Case-control diagnostic accuracy study Setting Academic dermatology department Participants Digital clinical images of pigmented cutaneous lesions (60 melanoma cases and 128 benign lesion controls), all with histologic diagnosis rendered by a board-certified dermatopathologist, obtained prior to biopsy in patients undergoing lesion removal as part of routine care. Main Outcome Measures Sensitivity, specificity, and positive and negative predictive values of four smart phone applications designed to aid non-clinician users in determining if their skin lesion is benign or malignant. Results Sensitivity of the four tested applications ranged from 6.8% to 98.1%. Specificity ranged from 30.4% to 93.7%. Positive predictive value ranged from 33.3% to 42.1%, and negative predictive value ranged from 65.4% to 97.0%. The highest sensitivity for melanoma diagnosis was observed for an application that sends the image directly to a board-certified dermatologist for analysis and the lowest sensitivity was observed for applications that use automated algorithms to analyze images. Conclusions The performance of smart phone applications in assessing melanoma risk is highly variable, and 3 out of 4 smart phone applications incorrectly classified 30% or more of melanomas as unconcerning. Reliance on these applications, which are not subject to regulatory oversight, in lieu of medical consultation, has the potential to delay the diagnosis of melanoma and to harm users. PMID:23325302

  5. Sensitivity of predicted bioaerosol exposure from open windrow composting facilities to ADMS dispersion model parameters.

    PubMed

    Douglas, P; Tyrrel, S F; Kinnersley, R P; Whelan, M; Longhurst, P J; Walsh, K; Pollard, S J T; Drew, G H

    2016-12-15

    Bioaerosols are released in elevated quantities from composting facilities and are associated with negative health effects, although dose-response relationships are not well understood, and require improved exposure classification. Dispersion modelling has great potential to improve exposure classification, but has not yet been extensively used or validated in this context. We present a sensitivity analysis of the ADMS dispersion model specific to input parameter ranges relevant to bioaerosol emissions from open windrow composting. This analysis provides an aid for model calibration by prioritising parameter adjustment and targeting independent parameter estimation. Results showed that predicted exposure was most sensitive to the wet and dry deposition modules and the majority of parameters relating to emission source characteristics, including pollutant emission velocity, source geometry and source height. This research improves understanding of the accuracy of model input data required to provide more reliable exposure predictions. Copyright © 2016. Published by Elsevier Ltd.

  6. Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.

    PubMed

    Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano

    2011-08-01

    Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. Conjunctivitis and Total IgE in Lacrimal Fluid: Lacrytest Screening

    PubMed Central

    Monzón, Susana; Arrondo, Elena; Bartra, Joan; Torres, Ferran; Basagaña, María; San Miguel, M. del Mar; Alonso, Rosario; Cisteró-Bahima, Anna

    2009-01-01

    Total tear IgE has been considered to play an important role in allergic conjunctivitis, and measurement has been considered useful for diagnosis. The aim of this study was to ascertain whether Lacrytest®, a new commercialised method to detect IgE levels in lacrimal fluid, could constitute a screening test for the diagnosis of allergic conjunctivitis. This was a cross-sectional study. Patients with seasonal and perennial allergic conjunctivitis, vernal keratoconjunctivitis and a control group were included. Clinical history, ophthalmic examination, skin prick test and conjunctival provocation test were obtained. Lacrytest® was later performed in all groups. Fifty-four patients were enrolled: thirty with IgE-mediated conjunctivitis and, nine with vernal keratoconjunctivitis and fifteen controls. Lacrytest® was negative in all controls, positive in 20% of the IgE-mediated conjunctivitis group and in 88.9% of the vernal keratoconjunctivitis group. Global statistically-significant differences were found among the three groups (P = .003). Sensitivity of the test in the IgE-mediated conjunctivitis group was 20%, specificity 100%, positive predictive value 100%, and negative predictive value 38.46%, while in VKC sensitivity was 88.88%, specificity 100%, positive predictive value 100%, and negative predictive value 93.75%. Our data confirm that this test is not useful for screening allergic conjunctivitis. Lacrytest®, while not providing any useful information to an allergist, could be helpful for ophthalmologists to confirm an IgE-mediated or VKC conjunctivitis. PMID:20975798

  8. Prospective evaluation of surgeon physical examination for detection of incisional hernias.

    PubMed

    Baucom, Rebeccah B; Beck, William C; Holzman, Michael D; Sharp, Kenneth W; Nealon, William H; Poulose, Benjamin K

    2014-03-01

    Surgeon physical examination is often used to monitor for hernia recurrence in clinical and research settings, despite a lack of information on its effectiveness. This study aims to compare surgeon-reviewed CT with surgeon physical examination for the detection of incisional hernia. General surgery patients with an earlier abdominal operation and a recent viewable CT scan of the abdomen and pelvis were enrolled prospectively. Patients with a stoma, fistula, or soft-tissue infection were excluded. Surgeon-reviewed CT was treated as the gold standard. Patients were stratified by body mass index into nonobese (body mass index <30) and obese groups. Testing characteristics and real-world performance, including positive predictive value and negative predictive value, were calculated. One hundred and eighty-one patients (mean age 54 years, 68% female) were enrolled. Hernia prevalence was 55%. Mean area of hernias was 44.6 cm(2). Surgeon physical examination had a low sensitivity (77%) and negative predictive value (77%). This difference was more pronounced in obese patients, with sensitivity of 73% and negative predictive value 69%. Surgeon physical examination is inferior to CT for detection of incisional hernia, and fails to detect approximately 23% of hernias. In obese patients, 31% of hernias are missed by surgeon physical examination. This has important implications for clinical follow-up and design of studies evaluating hernia recurrence, as ascertainment of this result must be reliable and accurate. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Questionnaire Predictors of Atopy in a US Population Sample: Findings From the National Health and Nutrition Examination Survey, 2005–2006

    PubMed Central

    Hoppin, Jane A.; Jaramillo, Renee; Salo, Paivi; Sandler, Dale P.; London, Stephanie J.; Zeldin, Darryl C.

    2011-01-01

    Allergic conditions and biochemical measures are both used to characterize atopy. To assess questionnaires’ ability to predict biochemical measures of atopy, the authors used data on 5 allergic conditions (allergy, hay fever, eczema, rhinitis, and itchy rash) and serum-specific immunoglobulin E (IgE) levels from the 2005–2006 National Health and Nutrition Examination Survey. Atopy was defined as 1 or more positive specific IgEs (≥0.35 kU/L). Questionnaire responses were assessed for sensitivity, specificity, and positive and negative predictive values for atopy. In this population-based US sample, 44% of participants were specific IgE-positive and 53% reported at least 1 allergic condition. Discordance between atopy and allergic conditions was considerable; 37% of persons with atopy reported no allergic condition, and 48% of persons who reported an allergic condition were not atopic. Thus, no combination of self-reported allergic conditions achieved both high sensitivity and high specificity for IgE. The positive predictive value of reported allergic conditions for atopy ranged from 50% for eczema to 72% for hay fever, while the negative predictive value ranged from 57% for eczema to 65% for any condition. Given the high proportion of asymptomatic participants who were specific IgE-positive and persons who reported allergic conditions but were specific IgE-negative, it is unlikely that questionnaires will ever capture the same participants as those found to be atopic by biochemical measures. PMID:21273397

  10. Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults.

    PubMed

    Kassem, T W; Abdelaziz, O; Emad-Eldin, S

    2017-10-01

    The purpose of this study was to evaluate the clinical utility of 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG-PET/CT) in the follow-up of adult patients with soft tissue sarcomas. We prospectively evaluated 37 consecutive patients with known soft tissue sarcoma with 18 F-FDG-PET/CT examination for suspected recurrence of disease. They were 21 men and 16 women with a mean age of 49.6±10.6 (SD) years (range, 34-75years). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 18 F-FDG-PET/CT examination were calculated on a per patient basis. 18 F-FDG-PET/CT showed an overall diagnostic accuracy of 91.8%, sensitivity of 90% and a specificity of 100%. The positive predictive value and negative predictive value were 100 and 70%, respectively. The 18 F-FDG-PET/CT interpretations were correct in 34/37 patients (91.8%). Incorrect interpretations occurred in three patients (8.1%). Reasons for false negative findings were low 18 F-FDG uptake of local recurrence in one patient and low 18 F-FDG uptake of subcentimetric inguinal lymph node metastases. 18 F-FDG-PET/CT has a high diagnostic value in the follow-up of patients with soft tissue sarcoma. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. [Primary cervical cancer screening].

    PubMed

    Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María

    2015-01-01

    Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  12. Utility of a routine urinalysis in children who require clean intermittent catheterization.

    PubMed

    Forster, C S; Haslam, D B; Jackson, E; Goldstein, S L

    2017-10-01

    Children who require clean intermittent catheterization (CIC) frequently have positive urine cultures. However, diagnosing a urinary tract infection (UTI) can be difficult, as there are no standardized criteria. Routine urinalysis (UA) has good predictive accuracy for UTI in the general pediatric population, but data are limited on the utility of routine UA in the population of children who require CIC. To determine the utility of UA parameters (e.g. leukocyte esterase, nitrites, and pyuria) to predict UTI in children who require CIC, and identify a composite UA that has maximal predictive accuracy for UTI. A cross-sectional study of 133 children who required CIC, and had a UA and urine culture sent as part of standard of care. Patients in the no-UTI group all had UA and urine cultures sent as part of routine urodynamics, and were asymptomatic. Patients included in the UTI group had growth of ≥50,000 colony-forming units/ml of a known uropathogen on urine culture, in addition to two or more of the following symptoms: fever, abdominal pain, back pain, foul-smelling urine, new or worse incontinence, and pain with catheterization. Categorical data were compared using Chi-squared test, and continuous data were compared with Student's t-test. Sensitivity, specificity, and positive and negative predictive values were calculated for individual UA parameters, as well as the composite UA. Logistic regression was performed on potential composite UA models to identify the model that best fit the data. There was a higher proportion of patients in the no-UTI group with negative leukocyte esterase compared with the UTI group. There was a higher proportion of patients with UTI who had large leukocyte esterase and positive nitrites compared with the no-UTI group (Summary Figure). There was no between-group difference in urinary white blood cells. Positive nitrites were the most specific (84.4%) for UTI. None of the parameters had a high positive predictive value, while all had high negative predictive values. The composite model with the best Akaike information criterion was >10 urinary white blood cells and either moderate or large leukocyte esterase, which had a positive predictive value of 33.3 and a negative predictive value of 90.4. Routine UA had limited sensitivity, but moderate specificity, in predicting UTI in children who required CIC. The composite UA and moderate or large leukocyte esterase both had good negative predictive values for the outcome of UTI. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. Evaluating the Capabilities of Soil Enthalpy, Soil Moisture and Soil Temperature in Predicting Seasonal Precipitation

    NASA Astrophysics Data System (ADS)

    Zhao, Changyu; Chen, Haishan; Sun, Shanlei

    2018-04-01

    Soil enthalpy ( H) contains the combined effects of both soil moisture ( w) and soil temperature ( T) in the land surface hydrothermal process. In this study, the sensitivities of H to w and T are investigated using the multi-linear regression method. Results indicate that T generally makes positive contributions to H, while w exhibits different (positive or negative) impacts due to soil ice effects. For example, w negatively contributes to H if soil contains more ice; however, after soil ice melts, w exerts positive contributions. In particular, due to lower w interannual variabilities in the deep soil layer (i.e., the fifth layer), H is more sensitive to T than to w. Moreover, to compare the potential capabilities of H, w and T in precipitation ( P) prediction, the Huanghe-Huaihe Basin (HHB) and Southeast China (SEC), with similar sensitivities of H to w and T, are selected. Analyses show that, despite similar spatial distributions of H-P and T-P correlation coefficients, the former values are always higher than the latter ones. Furthermore, H provides the most effective signals for P prediction over HHB and SEC, i.e., a significant leading correlation between May H and early summer (June) P. In summary, H, which integrates the effects of T and w as an independent variable, has greater capabilities in monitoring land surface heating and improving seasonal P prediction relative to individual land surface factors (e.g., T and w).

  14. Screening for depression in advanced disease: psychometric properties, sensitivity, and specificity of two items of the Palliative Care Outcome Scale (POS).

    PubMed

    Antunes, Bárbara; Murtagh, Fliss; Bausewein, Claudia; Harding, Richard; Higginson, Irene J

    2015-02-01

    Depression is common among patients with advanced disease but often difficult to detect. To assess the Palliative care Outcome Scale (POS) (10 items) against the Geriatric Depression Scale (GDS)-10 total score and the Hospital Anxiety and Depression Scale (HADS)-Depression subscale total score and determine if the POS has appropriate items to screen for depression among people with advanced disease. This was a secondary analysis performed on five studies. Four psychometric properties were assessed: data quality, scaling assumptions, acceptability, and internal consistency (reliability). Receiver operating characteristic (ROC) curves were used to determine the area under the curve. Sensitivity, specificity, positive and negative predictive values, false positive and negative rates, and positive and negative likelihood ratios were computed. The overall sample had 416 patients from Germany and England: 144 had cancer and 267 had nonmalignant conditions. Prevalence of depression across the sample was 17.5%. Floor and ceiling effects were rare. Cronbach's alpha coefficients for POS items 7 and 8 summed, GDS-10 and HADS-Depression items varied: 0.61 (heart failure) and 0.80 (cancer). Two items combined (Item 7-feeling depressed and Item 8-feeling good about yourself) consistently presented the highest area under the ROC curve, ranging from 0.76 (95% CI 0.60, 0.93) (Germany, lung cancer) to 0.97 (95% CI 0.91, 1.0) (heart failure), highest negative predictive value, and lowest false negative rate. For the overall sample, the cutoff 2/3 presented a negative predictive value of 89.4% (95% CI 84.7, 92.8) and false negative rate of 10.6 (95% CI 7.2, 15.3). POS items 7 and 8 summed are potentially useful to screen for depression in advanced disease populations. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  15. Negative impacts of climate change on cereal yields: statistical evidence from France

    NASA Astrophysics Data System (ADS)

    Gammans, Matthew; Mérel, Pierre; Ortiz-Bobea, Ariel

    2017-05-01

    In several world regions, climate change is predicted to negatively affect crop productivity. The recent statistical yield literature emphasizes the importance of flexibly accounting for the distribution of growing-season temperature to better represent the effects of warming on crop yields. We estimate a flexible statistical yield model using a long panel from France to investigate the impacts of temperature and precipitation changes on wheat and barley yields. Winter varieties appear sensitive to extreme cold after planting. All yields respond negatively to an increase in spring-summer temperatures and are a decreasing function of precipitation about historical precipitation levels. Crop yields are predicted to be negatively affected by climate change under a wide range of climate models and emissions scenarios. Under warming scenario RCP8.5 and holding growing areas and technology constant, our model ensemble predicts a 21.0% decline in winter wheat yield, a 17.3% decline in winter barley yield, and a 33.6% decline in spring barley yield by the end of the century. Uncertainty from climate projections dominates uncertainty from the statistical model. Finally, our model predicts that continuing technology trends would counterbalance most of the effects of climate change.

  16. Can dental pulp calcification predict the risk of ischemic cardiovascular disease?

    PubMed

    Khojastepour, Leila; Bronoosh, Pegah; Khosropanah, Shahdad; Rahimi, Elham

    2013-09-01

    To report the association of pulp calcification with that of cardiovascular disease (CVD) using digital panoramic dental radiographs. Digital panoramic radiographs of patients referred from the angiography department were included if the patient was under 55 years old and had non-restored or minimally restored molars and canines. An oral and maxillofacial radiologist evaluated the images for pulpal calcifications in the selected teeth. The sensitivity, specificity, positive predictive value and negative predictive value of panoramic radiography in predicting CVD were calculated. Out of 122 patients who met the criteria, 68.2% of the patients with CVD had pulp chamber calcifications. Pulp calcification in panoramic radiography had a sensitivity of 68.9% to predict CVD. This study demonstrates that patients with CVD show an increased incidence of pulp calcification compared with healthy patients. The findings suggest that pulp calcification on panoramic radiography may have possibilities for use in CVD screening.

  17. The bacterial meningitis score to distinguish bacterial from aseptic meningitis in children from Sao Paulo, Brazil.

    PubMed

    Mekitarian Filho, Eduardo; Horita, Sérgio Massaru; Gilio, Alfredo Elias; Alves, Anna Cláudia Dominguez; Nigrovic, Lise E

    2013-09-01

    In a retrospective cohort of 494 children with meningitis in Sao Paulo, Brazil, the Bacterial Meningitis Score identified all the children with bacterial meningitis (sensitivity 100%, 95% confidence interval: 92-100% and negative predictive value 100%, 95% confidence interval: 98-100%). Addition of cerebrospinal fluid lactate to the score did not improve clinical prediction rule performance.

  18. Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing

    PubMed Central

    Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian

    2017-01-01

    Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274

  19. [Comparison of two quantitative methods of endobronchial ultrasound real-time elastography for evaluating intrathoracic lymph nodes].

    PubMed

    Mao, X W; Yang, J Y; Zheng, X X; Wang, L; Zhu, L; Li, Y; Xiong, H K; Sun, J Y

    2017-06-12

    Objective: To compare the clinical value of two quantitative methods in analyzing endobronchial ultrasound real-time elastography (EBUS-RTE) images for evaluating intrathoracic lymph nodes. Methods: From January 2014 to April 2014, EBUS-RTE examination was performed in patients who received EBUS-TBNA examination in Shanghai Chest Hospital. Each intrathoracic lymph node had a selected EBUS-RTE image. Stiff area ratio and mean hue value of region of interest (ROI) in each image were calculated respectively. The final diagnosis of lymph node was based on the pathologic/microbiologic results of EBUS-TBNA, pathologic/microbiologic results of other examinations and clinical following-up. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were evaluated for distinguishing malignant and benign lesions. Results: Fifty-six patients and 68 lymph nodes were enrolled in this study, of which 35 lymph nodes were malignant and 33 lymph nodes were benign. The stiff area ratio and mean hue value of benign and malignant lesions were 0.32±0.29, 0.62±0.20 and 109.99±28.13, 141.62±17.52, respectively, and statistical differences were found in both of those two methods ( t =-5.14, P <0.01; t =-5.53, P <0.01). The area under curves was 0.813, 0.814 in stiff area ratio and mean hue value, respectively. The optimal diagnostic cut-off value of stiff area ratio was 0.48, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 82.86%, 81.82%, 82.86%, 81.82% and 82.35%, respectively. The optimal diagnostic cut-off value of mean hue value was 126.28, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 85.71%, 75.76%, 78.95%, 83.33% and 80.88%, respectively. Conclusion: Both the stiff area ratio and mean hue value methods can be used for analyzing EBUS-RTE images quantitatively, having the value of differentiating benign and malignant intrathoracic lymph nodes, and the stiff area ratio is better than the mean hue value between the two methods.

  20. Evaluation of autofluorescence and toluidine blue in the differentiation of oral dysplastic and neoplastic lesions from non dysplastic and neoplastic lesions: a cross-sectional study

    NASA Astrophysics Data System (ADS)

    Petruzzi, Massimo; Lucchese, Alberta; Nardi, Gianna Maria; Lauritano, Dorina; Favia, Gianfranco; Serpico, Rosario; Grassi, Felice Roberto

    2014-07-01

    The objective was to compare toluidine blue (TB) and autofluorescence (AF) for the detection of oral dysplasia and squamous cell carcinoma (OSCC) in clinically suspicious lesions according to conventional examination. Fifty-six clinically suspicious lesions were subjected to AF and TB examination. Data were compared using two different scenarios: in the first, mild dysplasia was considered as positive, while in the second, it was considered as negative. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), accuracy, and concordance were calculated. AF sensitivity and specificity were 70.0 and 57.7%, respectively, while TB showed a sensitivity of 80% and a specificity of 61.5%. The sensitivity increased in the second scenario in both AF (76.5%) and TB (88.2%). The specificity decreased in AF and TB, showing the same value (51.3%). PPV was higher in TB than in AF (70.6 versus 65.6%) and similarly for NPV (72.7 versus 62.5%). In the second scenario, TB PPV was 44.1% and NPV was 90.9% AF PPV was 40.6% and NPV was 83.3%. TB showed greater accuracy than AF in the first scenario (62.5 versus 58.9%). AF and TB are both sensitive but not specific in OSCC and dysplasia diagnosis.

  1. Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

    PubMed

    Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui

    2014-01-01

    The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.

  2. Validity of rapid antigen detection testing in group A beta-hemolytic streptococcal tonsillopharyngitis.

    PubMed

    Küçük, Oznur; Biçer, Suat; Giray, Tuba; Cöl, Defne; Erdağ, Gülay Ciler; Gürol, Yeşim; Kaspar, Ciğdem E; Vitrinel, Ayça

    2014-02-01

    To evaluate the utility of rapid antigen detection testing (RADT) for the diagnosis of group A beta-hemolytic streptococcal tonsillopharyngitis in children, and to detect the sensitivity and specificity of rapid antigen detection of group A beta-hemolytic streptococci from throat specimen compared with throat culture. Rapid antigen detection and throat culture results for group A beta-hemolytic streptococci from outpatients attending university hospital between 1st January 2011 and 31st of December 2011 were evaluated retrospectively. The antigen test negative-throat culture positive patients were investigated for streptococcal carriage. For this purpose, the throat culture results taken from these patients were reviewed after treatment. Eight hundred and ninetytwo children were included in the studywith a mean age of 5.34 y. There were 639 and 253 children in two groups with age of 0-6 and 7-17 y, RADT sensitivity and specificity were found to be 59.5 % and 97.2 %, respectively. The positive predictive value was 87.1 %, whereas negative predictive value was 88.4 %. After treatment of 74 patients with throat culture positive and antigen test negative. Group A beta-hemolytic streptococci were isolated in 12 of them (16.2 %) and accepted as a carrier. The low sensitivity of the RADT may be related to streptococcal carriage in some patients. The throat culture should be repeated after treatment to detect streptococcal carriage.

  3. Detection of right-to-left shunts: comparison between the International Consensus and Spencer Logarithmic Scale criteria.

    PubMed

    Lao, Annabelle Y; Sharma, Vijay K; Tsivgoulis, Georgios; Frey, James L; Malkoff, Marc D; Navarro, Jose C; Alexandrov, Andrei V

    2008-10-01

    International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.

  4. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    PubMed

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  5. Characterization of Focal Liver Lesions using CEUS and MRI with Liver-Specific Contrast Media: Experience of a Single Radiologic Center.

    PubMed

    Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael

    2017-12-01

     The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL).  83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared.  The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2.  CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Adolescent Conflict Appraisals Moderate the Link Between Marital Conflict and Physiological Stress Reactivity.

    PubMed

    Lucas-Thompson, Rachel G; Lunkenheimer, Erika S; Granger, Douglas A

    2017-03-01

    The goal of this study was to advance understanding of how adolescent conflict appraisals contribute uniquely, and in combination with interparental conflict behavior, to individual differences in adolescent physiological reactivity. Saliva samples were collected from 153 adolescents (52% female; ages 10-17 years) before and after the Trier Social Stress Test. Saliva was assayed for cortisol and alpha-amylase. Results revealed interactive effects between marital conflict and conflict appraisals. For youth who appraised parental conflict negatively (particularly as threatening), negative marital conflict predicted dampened reactivity; for youth who appraised parental conflict less negatively, negative marital conflict predicted heightened reactivity. These findings support the notion that the family context and youth appraisals of family relationships are linked with individual differences in biological sensitivity to context. © 2016 The Authors. Journal of Research on Adolescence © 2016 Society for Research on Adolescence.

  7. OBSERVABLE INDICATORS OF THE SENSITIVITY OF PM 2.5 NITRATE TO EMISSION REDUCTIONS, PART II: SENSITIVITY TO ERRORS IN TOTAL AMMONIA AND TOTAL NITRATE OF THE CMAQ-PREDICTED NONLINEAR EFFECT OF SO 2 EMISSION REDUCTIONS

    EPA Science Inventory

    The inorganic aerosol system of sulfate, nitrate, and ammonium can respond nonlinearly to changes in precursor sulfur dioxide (SO2) emissions. The potential increase in nitrate, when sulfate is reduced and the associated ammonia is released, can negate the sulfate mass...

  8. Accidental falls in hospital inpatients: evaluation of sensitivity and specificity of two risk assessment tools.

    PubMed

    Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura

    2010-03-01

    This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.

  9. PCR colorimetric dot-blot assay and clinical pretest probability for diagnosis of Pulmonary Tuberculosis in Smear-Negative patients

    PubMed Central

    Scherer, Luciene Cardoso; Sperhacke, Rosa Dea; Jarczewski, Carla; Cafrune, Patrícia I; Minghelli, Simone; Ribeiro, Marta Osório; Mello, Fernanda CQ; Ruffino-Netto, Antonio; Rossetti, Maria LR; Kritski, Afrânio L

    2007-01-01

    Background Smear-negative pulmonary tuberculosis (SNPTB) accounts for 30% of Pulmonary Tuberculosis (PTB) cases reported annually in developing nations. Polymerase chain reaction (PCR) may provide an alternative for the rapid detection of Mycobacterium tuberculosis (MTB); however little data are available regarding the clinical utility of PCR in SNPTB, in a setting with a high burden of TB/HIV co-infection. Methods To evaluate the performance of the PCR dot-blot in parallel with pretest probability (Clinical Suspicion) in patients suspected of having SNPTB, a prospective study of 213 individuals with clinical and radiological suspicion of SNPTB was carried out from May 2003 to May 2004, in a TB/HIV reference hospital. Respiratory specialists estimated the pretest probability of active disease into high, intermediate, low categories. Expectorated sputum was examined by direct microscopy (Ziehl-Neelsen staining), culture (Lowenstein Jensen) and PCR dot-blot. Gold standard was based on culture positivity combined with the clinical definition of PTB. Results In smear-negative and HIV subjects, active PTB was diagnosed in 28.4% (43/151) and 42.2% (19/45), respectively. In the high, intermediate and low pretest probability categories active PTB was diagnosed in 67.4% (31/46), 24% (6/25), 7.5% (6/80), respectively. PCR had sensitivity of 65% (CI 95%: 50%–78%) and specificity of 83% (CI 95%: 75%–89%). There was no difference in the sensitivity of PCR in relation to HIV status. PCR sensitivity and specificity among non-previously TB treated and those treated in the past were, respectively: 69%, 43%, 85% and 80%. The high pretest probability, when used as a diagnostic test, had sensitivity of 72% (CI 95%:57%–84%) and specificity of 86% (CI 95%:78%–92%). Using the PCR dot-blot in parallel with high pretest probability as a diagnostic test, sensitivity, specificity, positive and negative predictive values were: 90%, 71%, 75%, and 88%, respectively. Among non-previously TB treated and HIV subjects, this approach had sensitivity, specificity, positive and negative predictive values of 91%, 79%, 81%, 90%, and 90%, 65%, 72%, 88%, respectively. Conclusion PCR dot-blot associated with a high clinical suspicion may provide an important contribution to the diagnosis of SNPTB mainly in patients that have not been previously treated attended at a TB/HIV reference hospital. PMID:18096069

  10. Validity of the International Classification of Diseases 10th revision code for hospitalisation with hyponatraemia in elderly patients

    PubMed Central

    Gandhi, Sonja; Shariff, Salimah Z; Fleet, Jamie L; Weir, Matthew A; Jain, Arsh K; Garg, Amit X

    2012-01-01

    Objective To evaluate the validity of the International Classification of Diseases, 10th Revision (ICD-10) diagnosis code for hyponatraemia (E87.1) in two settings: at presentation to the emergency department and at hospital admission. Design Population-based retrospective validation study. Setting Twelve hospitals in Southwestern Ontario, Canada, from 2003 to 2010. Participants Patients aged 66 years and older with serum sodium laboratory measurements at presentation to the emergency department (n=64 581) and at hospital admission (n=64 499). Main outcome measures Sensitivity, specificity, positive predictive value and negative predictive value comparing various ICD-10 diagnostic coding algorithms for hyponatraemia to serum sodium laboratory measurements (reference standard). Median serum sodium values comparing patients who were code positive and code negative for hyponatraemia. Results The sensitivity of hyponatraemia (defined by a serum sodium ≤132 mmol/l) for the best-performing ICD-10 coding algorithm was 7.5% at presentation to the emergency department (95% CI 7.0% to 8.2%) and 10.6% at hospital admission (95% CI 9.9% to 11.2%). Both specificities were greater than 99%. In the two settings, the positive predictive values were 96.4% (95% CI 94.6% to 97.6%) and 82.3% (95% CI 80.0% to 84.4%), while the negative predictive values were 89.2% (95% CI 89.0% to 89.5%) and 87.1% (95% CI 86.8% to 87.4%). In patients who were code positive for hyponatraemia, the median (IQR) serum sodium measurements were 123 (119–126) mmol/l and 125 (120–130) mmol/l in the two settings. In code negative patients, the measurements were 138 (136–140) mmol/l and 137 (135–139) mmol/l. Conclusions The ICD-10 diagnostic code for hyponatraemia differentiates between two groups of patients with distinct serum sodium measurements at both presentation to the emergency department and at hospital admission. However, these codes underestimate the true incidence of hyponatraemia due to low sensitivity. PMID:23274673

  11. Predicting out-of-office blood pressure level using repeated measurements in the clinic: an observational cohort study

    PubMed Central

    Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.

    2014-01-01

    Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295

  12. Comparison between esophagography and chest computed tomography for evaluation of leaks after esophagectomy and gastric pull-through.

    PubMed

    Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A

    2013-03-01

    To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.

  13. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    PubMed

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  14. Sensitivity and specificity of the 'knee-up test' for estimation of the American Spinal Injury Association Impairment Scale in patients with acute motor incomplete cervical spinal cord injury.

    PubMed

    Yugué, Itaru; Okada, Seiji; Maeda, Takeshi; Ueta, Takayoshi; Shiba, Keiichiro

    2018-04-01

    A retrospective study. Precise classification of the neurological state of patients with acute cervical spinal cord injury (CSCI) can be challenging. This study proposed a useful and simple clinical method to help classify patients with incomplete CSCI. Spinal Injuries Centre, Japan. The sensitivity and specificity of the 'knee-up test' were evaluated in patients with acute CSCI classified as American Spinal Injury Association Impairment Scale (AIS) C or D. The result is positive if the patient can lift the knee in one or both legs to an upright position, whereas the result is negative if the patient is unable to lift the knee in either leg to an upright position. The AIS of these patients was classified according to a strict computerised algorithm designed by Walden et al., and the knee-up test was tested by non-expert examiners. Among the 200 patients, 95 and 105 were classified as AIS C and AIS D, respectively. Overall, 126 and 74 patients demonstrated positive and negative results, respectively, when evaluated using the knee-up test. A total of 104 patients with positive results and 73 patients with negative results were classified as AIS D and AIS C, respectively. The sensitivity, specificity, positive predictive and negative predictive values of this test for all patients were 99.1, 76.8, 82.5 and 98.7, respectively. The knee-up test may allow easy and highly accurate estimation, without the need for special skills, of AIS classification for patients with incomplete CSCI.

  15. Evaluation of the Predictive Validity of Thermography in Identifying Extravasation With Intravenous Chemotherapy Infusions

    PubMed Central

    Murayama, Ryoko; Tanabe, Hidenori; Oe, Makoto; Motoo, Yoshiharu; Wagatsuma, Takanori; Michibuchi, Michiko; Kinoshita, Sachiko; Sakai, Keiko; Konya, Chizuko; Sugama, Junko; Sanada, Hiromi

    2017-01-01

    Early detection of extravasation is important, but conventional methods of detection lack objectivity and reliability. This study evaluated the predictive validity of thermography for identifying extravasation during intravenous antineoplastic therapy. Of 257 patients who received chemotherapy through peripheral veins, extravasation was identified in 26. Thermography was performed every 15 to 30 minutes during the infusions. Sensitivity, specificity, positive predictive value, and negative predictive value using thermography were 84.6%, 94.8%, 64.7%, and 98.2%, respectively. This study showed that thermography offers an accurate prediction of extravasation. PMID:29112585

  16. Next-generation sequencing of circulating tumor DNA to predict recurrence in triple-negative breast cancer patients with residual disease after neoadjuvant chemotherapy.

    PubMed

    Chen, Yu-Hsiang; Hancock, Bradley A; Solzak, Jeffrey P; Brinza, Dumitru; Scafe, Charles; Miller, Kathy D; Radovich, Milan

    2017-01-01

    Next-generation sequencing to detect circulating tumor DNA is a minimally invasive method for tumor genotyping and monitoring therapeutic response. The majority of studies have focused on detecting circulating tumor DNA from patients with metastatic disease. Herein, we tested whether circulating tumor DNA could be used as a biomarker to predict relapse in triple-negative breast cancer patients with residual disease after neoadjuvant chemotherapy. In this study, we analyzed samples from 38 early-stage triple-negative breast cancer patients with matched tumor, blood, and plasma. Extracted DNA underwent library preparation and amplification using the Oncomine Research Panel consisting of 134 cancer genes, followed by high-coverage sequencing and bioinformatics. We detected high-quality somatic mutations from primary tumors in 33 of 38 patients. TP53 mutations were the most prevalent (82%) followed by PIK3CA (16%). Of the 33 patients who had a mutation identified in their primary tumor, we were able to detect circulating tumor DNA mutations in the plasma of four patients (three TP53 mutations, one AKT1 mutation, one CDKN2A mutation). All four patients had recurrence of their disease (100% specificity), but sensitivity was limited to detecting only 4 of 13 patients who clinically relapsed (31% sensitivity). Notably, all four patients had a rapid recurrence (0.3, 4.0, 5.3, and 8.9 months). Patients with detectable circulating tumor DNA had an inferior disease free survival ( p  < 0.0001; median disease-free survival: 4.6 mos. vs. not reached; hazard ratio = 12.6, 95% confidence interval: 3.06-52.2). Our study shows that next-generation circulating tumor DNA sequencing of triple-negative breast cancer patients with residual disease after neoadjuvant chemotherapy can predict recurrence with high specificity, but moderate sensitivity. For those patients where circulating tumor DNA is detected, recurrence is rapid.

  17. Prediction of early and late preeclampsia by flow-mediated dilation of the brachial artery*

    PubMed Central

    Brandão, Augusto Henriques Fulgêncio; Evangelista, Aline Aarão; Martins, Raphaela Menin Franco; Leite, Henrique Vítor; Cabral, Antônio Carlos Vieira

    2014-01-01

    Objective To assess the accuracy in the prediction of both early and late preeclampsia by flow-mediated dilation of the brachial artery (FMD), a biophysical marker for endothelial dysfunction. Materials and Methods A total of 91 patients, considered at high risk for development of preeclampsia were submitted to brachial artery FMD between 24 and 28 weeks of gestation. Results Nineteen out of the selected patients developed preeclampsia, 8 in its early form and 11 in the late form. With a cut-off value of 6.5%, the FMD sensitivity for early preeclampsia prediction was 75.0%, with specificity of 73.3%, positive predictive value (PPV) of 32.4% and negative predictive value (NPV) of 91.9%. For the prediction of late preeclampsia, sensitivity = 83.3%, specificity = 73.2%, PPV = 34.4% and NPV = 96.2% were observed. And for the prediction of all associated forms of preeclampsia, sensitivity = 84.2%, specificity = 73.6%, PPV = 45.7% and NPV = 94.6% were observed. Conclusion FMD of the brachial artery is a test with good accuracy in the prediction of both early and late preeclampsia, which may represent a positive impact on the follow-up of pregnant women at high risk for developing this syndrome. PMID:25741086

  18. False-negative BRAF V600E mutation results on fine-needle aspiration cytology of papillary thyroid carcinoma.

    PubMed

    Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung

    2017-11-13

    The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.

  19. Associations of group level popularity with observed behavior and influence in a dyadic context.

    PubMed

    Lansu, Tessa A M; Cillessen, Antonius H N

    2015-12-01

    This study examined the association between popularity in the peer group and adolescents' behavior in a dyadic context. After collecting peer nominations for popularity, 218 early adolescents (M(age) = 11.0 years) in 109 randomly composed same-sex dyads participated in a discussion task where they planned a party for their classroom. From digital recordings of the sessions, each participant's influence, involvement, skillful leadership, coercive resource control, submissiveness, positivity, and negativity were observed. Analyses with the actor-partner interdependence model (APIM) demonstrated that for girls high group level popularity was associated with a socially sensitive interaction style and influence in the dyadic context. For both boys and girls, the interaction partner's group level popularity negatively predicted their use of coercive resource control strategies and negative behavior in the dyad. For girls, in addition, the interaction partner's group level popularity also positively predicted their submissiveness and negatively predicted their task influence. These results indicate that, in particular for girls, adolescents' group level popularity plays an important role in the behavior of both peers in a cooperative dyadic context. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. The influence of impression management scales on the Personality Assessment Inventory in the epilepsy monitoring unit.

    PubMed

    Purdom, Catherine L; Kirlin, Kristin A; Hoerth, Matthew T; Noe, Katherine H; Drazkowski, Joseph F; Sirven, Joseph I; Locke, Dona E C

    2012-12-01

    The Somatic Complaints scale (SOM) and Conversion subscale (SOM-C) of the Personality Assessment Inventory perform best in classifying psychogenic non-epileptic seizures (PNES) from epileptic seizures (ES); however, the impact of positive impression management (PIM) and negative impression management (NIM) scales on SOM and SOM-C classification has not been examined. We studied 187 patients from an epilepsy monitoring unit with confirmed PNES or ES. On SOM, the best cut score was 72.5 T when PIM was elevated and 69.5 T when there was no bias. On SOM-C, when PIM was elevated, the best cut score was 67.5 T and 76.5 T when there was no bias. Negative impression management elevations (n=9) were too infrequent to analyze separately. Despite similarities in classification accuracy, there were differences in sensitivity and specificity with and without PIM, impacting positive and negative predictive values. The presence of PIM bias generally increases positive predictive power of SOM and SOM-C but decreases negative predictive power. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Incremental validity of mindfulness skills in relation to emotional dysregulation among a young adult community sample.

    PubMed

    Vujanovic, Anka A; Bonn-Miller, Marcel O; Bernstein, Amit; McKee, Laura G; Zvolensky, Michael J

    2010-01-01

    The present investigation examined the incremental predictive validity of mindfulness skills, as measured by the Kentucky Inventory of Mindfulness Skills (KIMS), in relation to multiple facets of emotional dysregulation, as indexed by the Difficulties in Emotion Regulation Scale (DERS), above and beyond variance explained by negative affectivity, anxiety sensitivity, and distress tolerance. Participants were a nonclinical community sample of 193 young adults (106 women, 87 men; M(age) = 23.91 years). The KIMS Accepting without Judgment subscale was incrementally negatively predictive of all facets of emotional dysregulation, as measured by the DERS. Furthermore, KIMS Acting with Awareness was incrementally negatively related to difficulties engaging in goal-directed behavior. Additionally, both observing and describing mindfulness skills were incrementally negatively related to lack of emotional awareness, and describing skills also were incrementally negatively related to lack of emotional clarity. Findings are discussed in relation to advancing scientific understanding of emotional dysregulation from a mindfulness skills-based framework.

  2. Predictive genetic testing for the identification of high-risk groups: a simulation study on the impact of predictive ability

    PubMed Central

    2011-01-01

    Background Genetic risk models could potentially be useful in identifying high-risk groups for the prevention of complex diseases. We investigated the performance of this risk stratification strategy by examining epidemiological parameters that impact the predictive ability of risk models. Methods We assessed sensitivity, specificity, and positive and negative predictive value for all possible risk thresholds that can define high-risk groups and investigated how these measures depend on the frequency of disease in the population, the frequency of the high-risk group, and the discriminative accuracy of the risk model, as assessed by the area under the receiver-operating characteristic curve (AUC). In a simulation study, we modeled genetic risk scores of 50 genes with equal odds ratios and genotype frequencies, and varied the odds ratios and the disease frequency across scenarios. We also performed a simulation of age-related macular degeneration risk prediction based on published odds ratios and frequencies for six genetic risk variants. Results We show that when the frequency of the high-risk group was lower than the disease frequency, positive predictive value increased with the AUC but sensitivity remained low. When the frequency of the high-risk group was higher than the disease frequency, sensitivity was high but positive predictive value remained low. When both frequencies were equal, both positive predictive value and sensitivity increased with increasing AUC, but higher AUC was needed to maximize both measures. Conclusions The performance of risk stratification is strongly determined by the frequency of the high-risk group relative to the frequency of disease in the population. The identification of high-risk groups with appreciable combinations of sensitivity and positive predictive value requires higher AUC. PMID:21797996

  3. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  4. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis.

    PubMed

    Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R

    2017-09-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.

  5. Performance assessment of urine flow cytometry (UFC) to screen urines to reflex to culture in immunocompetent and immunosuppressed hosts.

    PubMed

    Stefanovic, Aleksandra; Roscoe, Diane; Ranasinghe, Romali; Wong, Titus; Bryce, Elizabeth; Porter, Charlene; Lim, Adelina; Grant, Jennifer; Ng, Karen; Pudek, Morris

    2017-09-01

    Urine flow cytometry (UFC) is an automated method to quantify bacterial and white blood cell (WBC) counts. We aimed to determine whether a threshold for these parameters can be set to use UFC as a sensitive screen to predict which urine samples will subsequently grow in culture. Urines submitted to our microbiology laboratory at a tertiary care centre from 22 July 2015-17 February 2016 underwent UFC (Sysmex UF-1000i) analysis, regular urinalysis and urine culture. Positive urine cultures were defined as growth ≥104 c.f.u. ml-1 of organisms associated with urinary tract infections. The correlation of UFC bacterial and WBC counts with urine culture was assessed using receiver operating characteristics curves. The sensitivity (SN), specificity (SP), negative predictive values (NPVs), positive predictive values (PPVs) and false negative rate (FNR) were calculated at various thresholds in immunocompetent and immunosuppressed patients. A total of 15 046 urine specimens were submitted, of which 14 908 were analysable in the study. The average time to UFC result from receipt in the laboratory was 0.76 h (+/-1.04). The test performance at a set threshold of UFC bacteria ≥20 or WBC >5 was: SN=96.0 %, SP=39.2 %, PPV=47.0 %, NPV=94.5 % and FNR=4.0 %. This threshold eliminates 26 % of urine cultures. Immunosuppressed hosts had a lower sensitivity of 90.6 % and a higher FNR of 9.4 %. UFC is a rapid and sensitive method to screen out urine samples that will subsequently be negative and to reflex urines to culture that will subsequently grow. UFC results are available within 1 h from receipt and enable the elimination of culture when the set threshold is not met.

  6. Can 3'-Deoxy-3'-((18)F) Fluorothymidine Out Perform 2-Deoxy-2-((18)F) Fluoro-D-Glucose Positron Emission Tomography/Computed Tomography in the Diagnosis of Cervical Lymphadenopathy in Patients With Oral/Head and Neck Cancer?

    PubMed

    Schaefferkoetter, Joshua D; Carlson, Eric R; Heidel, Robert E

    2015-07-01

    The present study investigated the performance of cellular metabolism imaging with 2-deoxy-2-((18)F) fluoro-D-glucose (FDG) versus cellular proliferation imaging with 3'-deoxy-3'-((18)F) fluorothymidine (FLT) in the detection of cervical lymph node metastases in oral/head and neck cancer. We conducted a prospective cohort study to assess a head-to-head performance of FLT imaging and clinical FDG imaging for characterizing cervical lymph node metastases in patients with squamous cell carcinoma (SCC) of the oral/head and neck region. The primary predictor variable of the study was the presence of FDG or FLT avidity within the cervical lymph nodes. The primary outcome variable was the histologic presence of metastatic SCC in the cervical lymph nodes. The performance was reported in terms of the sensitivity, specificity, accuracy, and positive and negative predictive values. The overall accuracy for discriminating positive from negative lymph nodes was evaluated as a function of the positron emission tomography (PET) standardized uptake value (SUV). Receiver operating characteristic (ROC) analyses were performed for both tracers. Eleven patients undergoing surgical resection of SCC of the oral/head and neck region underwent preoperative FDG and FLT PET-computed tomography (CT) scans on separate days. The interpretation of the FDG PET-CT imaging resulted in sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 43.2, 99.5, 94.4, 88.9, and 94.7%, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for FLT PET-CT imaging was 75.7, 99.2, 97.1, 90.3, and 97.7%, respectively. The areas under the curve for the ROC curves were 0.9 and 0.84 for FDG and FLT, respectively. Poor correlation was observed between the SUV for FDG and FLT within the lymph nodes and tumors. FLT showed better overall performance for detecting lymphadenopathy on qualitative assessment within the total nodal population. This notwithstanding, FDG SUV performed better for pathologic discrimination within the visible lymph nodes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Developmental origins of infant emotion regulation: Mediation by temperamental negativity and moderation by maternal sensitivity.

    PubMed

    Thomas, Jenna C; Letourneau, Nicole; Campbell, Tavis S; Tomfohr-Madsen, Lianne; Giesbrecht, Gerald F

    2017-04-01

    Emotion regulation is essential to cognitive, social, and emotional development and difficulties with emotion regulation portend future socioemotional, academic, and behavioral difficulties. There is growing awareness that many developmental outcomes previously thought to begin their development in the postnatal period have their origins in the prenatal period. Thus, there is a need to integrate evidence of prenatal influences within established postnatal factors, such as infant temperament and maternal sensitivity. In the current study, prenatal depression, pregnancy anxiety, and diurnal cortisol patterns (i.e., the cortisol awakening response (CAR) and diurnal slope) were assessed in 254 relatively low-risk mother-infant pairs (primarily White, middle-class) in early (M = 15 weeks) and late pregnancy (M = 33 weeks). Mothers reported on infant temperamental negativity (Infant Behavior Questionnaire-Revised) at 3 months. At 6 months, maternal sensitivity (Parent Child Interaction Teaching Scale) and infant emotion regulation behavior (Laboratory Temperament Assessment Battery) were assessed. Greater pregnancy anxiety in early pregnancy and a blunted CAR in late pregnancy predicted higher infant temperamental negativity at 3 months, and those infants with higher temperamental negativity used fewer attentional regulation strategies and more avoidance (i.e., escape behavior) at 6 months. Furthermore, this indirect effect was moderated by maternal sensitivity whereby infants with elevated negativity demonstrated maladaptive emotion regulation at below average levels of maternal sensitivity. These findings suggest that the development of infant emotion regulation is influenced by the ways that prenatal exposures shape infant temperament and is further modified by postnatal caregiving. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Results of the two incidence screenings in the National Lung Screening Trial.

    PubMed

    Aberle, Denise R; DeMello, Sarah; Berg, Christine D; Black, William C; Brewer, Brenda; Church, Timothy R; Clingan, Kathy L; Duan, Fenghai; Fagerstrom, Richard M; Gareen, Ilana F; Gatsonis, Constantine A; Gierada, David S; Jain, Amanda; Jones, Gordon C; Mahon, Irene; Marcus, Pamela M; Rathmell, Joshua M; Sicks, JoRean

    2013-09-05

    The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).

  9. Perception is key? Does perceptual sensitivity and parenting behavior predict children's reactivity to others' emotions?

    PubMed

    Weeland, Joyce; Van den Akker, Alithe; Slagt, Meike; Putnam, Samuel

    2017-11-01

    When interacting with other people, both children's biological predispositions and past experiences play a role in how they will process and respond to social-emotional cues. Children may partly differ in their reactions to such cues because they differ in the threshold for perceiving such cues in general. Theoretically, perceptual sensitivity (i.e., the amount of detection of slight, low-intensity stimuli from the external environment independent of visual and auditory ability) might, therefore, provide us with specific information on individual differences in susceptibility to the environment. However, the temperament trait of perceptual sensitivity is highly understudied. In an experiment, we tested whether school-aged children's (N=521, 52.5% boys, M age =9.72years, SD=1.51) motor (facial electromyography) and affective (self-report) reactivities to dynamic facial expressions and vocalizations is predicted by their (parent-reported) perceptual sensitivity. Our results indicate that children's perceptual sensitivity predicts their motor reactivity to both happy and angry expressions and vocalizations. In addition, perceptual sensitivity interacted with positive (but not negative) parenting behavior in predicting children's motor reactivity to these emotions. Our findings suggest that perceptual sensitivity might indeed provide us with information on individual differences in reactivity to social-emotional cues, both alone and in interaction with parenting behavior. Because perceptual sensitivity focuses specifically on whether children perceive cues from their environment, and not on whether these cues cause arousal and/or whether children are able to regulate this arousal, it should be considered that perceptual sensitivity lies at the root of such individual differences. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Rapid screening for inflammatory neuropathies by standardized clinical criteria

    PubMed Central

    Tramontozzi, Louis A.

    2016-01-01

    Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273

  11. Noninvasive Electromagnetic Detection of Bladder Cancer

    PubMed Central

    Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe

    2014-01-01

    Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795

  12. Unacceptably High Error Rates in Vitek 2 Testing of Cefepime Susceptibility in Extended-Spectrum-β-Lactamase-Producing Escherichia coli

    PubMed Central

    Rhodes, Nathaniel J.; Richardson, Chad L.; Heraty, Ryan; Liu, Jiajun; Malczynski, Michael; Qi, Chao

    2014-01-01

    While a lack of concordance is known between gold standard MIC determinations and Vitek 2, the magnitude of the discrepancy and its impact on treatment decisions for extended-spectrum-β-lactamase (ESBL)-producing Escherichia coli are not. Clinical isolates of ESBL-producing E. coli were collected from blood, tissue, and body fluid samples from January 2003 to July 2009. Resistance genotypes were identified by PCR. Primary analyses evaluated the discordance between Vitek 2 and gold standard methods using cefepime susceptibility breakpoint cutoff values of 8, 4, and 2 μg/ml. The discrepancies in MICs between the methods were classified per convention as very major, major, and minor errors. Sensitivity, specificity, and positive and negative predictive values for susceptibility classifications were calculated. A total of 304 isolates were identified; 59% (179) of the isolates carried blaCTX-M, 47% (143) carried blaTEM, and 4% (12) carried blaSHV. At a breakpoint MIC of 8 μg/ml, Vitek 2 produced a categorical agreement of 66.8% and exhibited very major, major, and minor error rates of 23% (20/87 isolates), 5.1% (8/157 isolates), and 24% (73/304), respectively. The sensitivity, specificity, and positive and negative predictive values for a susceptibility breakpoint of 8 μg/ml were 94.9%, 61.2%, 72.3%, and 91.8%, respectively. The sensitivity, specificity, and positive and negative predictive values for a susceptibility breakpoint of 2 μg/ml were 83.8%, 65.3%, 41%, and 93.3%, respectively. Vitek 2 results in unacceptably high error rates for cefepime compared to those of agar dilution for ESBL-producing E. coli. Clinicians should be wary of making treatment decisions on the basis of Vitek 2 susceptibility results for ESBL-producing E. coli. PMID:24752253

  13. Preoperative Serum Thyrotropin to Thyroglobulin Ratio Is Effective for Thyroid Nodule Evaluation in Euthyroid Patients.

    PubMed

    Wang, Lina; Li, Hao; Yang, Zhongyuan; Guo, Zhuming; Zhang, Quan

    2015-07-01

    This study was designed to assess the efficiency of the serum thyrotropin to thyroglobulin ratio for thyroid nodule evaluation in euthyroid patients. Cross-sectional study. Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China. Retrospective analysis was performed for 400 previously untreated cases presenting with thyroid nodules. Thyroid function was tested with commercially available radioimmunoassays. The receiver operating characteristic curves were constructed to determine cutoff values. The efficacy of the thyrotropin:thyroglobulin ratio and thyroid-stimulating hormone for thyroid nodule evaluation was evaluated in terms of sensitivity, specificity, positive predictive value, positive likelihood ratio, negative likelihood ratio, and odds ratio. In receiver operating characteristic curve analysis, the area under the curve was 0.746 for the thyrotropin:thyroglobulin ratio and 0.659 for thyroid-stimulating hormone. With a cutoff point value of 24.97 IU/g for the thyrotropin:thyroglobulin ratio, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 78.9%, 60.8%, 75.5%, 2.01, and 0.35, respectively. The odds ratio for the thyrotropin:thyroglobulin ratio indicating malignancy was 5.80. With a cutoff point value of 1.525 µIU/mL for thyroid-stimulating hormone, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 74.0%, 53.2%, 70.8%, 1.58, and 0.49, respectively. The odds ratio indicating malignancy for thyroid-stimulating hormone was 3.23. Increasing preoperative serum thyrotropin:thyroglobulin ratio is a risk factor for thyroid carcinoma, and the correlation of the thyrotropin:thyroglobulin ratio to malignancy is higher than that for serum thyroid-stimulating hormone. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  14. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.

    PubMed

    Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh

    2015-01-01

    Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.

  15. Clinical application of the basic definition of malnutrition proposed by the European Society for Clinical Nutrition and Metabolism (ESPEN): Comparison with classical tools in geriatric care.

    PubMed

    Sánchez-Rodríguez, Dolores; Annweiler, Cédric; Ronquillo-Moreno, Natalia; Tortosa-Rodríguez, Andrea; Guillén-Solà, Anna; Vázquez-Ibar, Olga; Escalada, Ferran; Muniesa, Josep M; Marco, Ester

    Malnutrition is a prevalent condition related to adverse outcomes in older people. Our aim was to compare the diagnostic capacity of the malnutrition criteria of the European Society of Parenteral and Enteral Nutrition (ESPEN) with other classical diagnostic tools. Cohort study of 102 consecutive in-patients ≥70 years admitted for postacute rehabilitation. Patients were considered malnourished if their Mini-Nutritional Assessment-Short Form (MNA-SF) score was ≤11 and serum albumin <3 mg/dL or MNA-SF ≤ 11, serum albumin <3 mg/dL, and usual clinical signs and symptoms of malnutrition. Sensitivity, specificity, positive and negative predictive values, accuracy likelihood ratios, and kappa values were calculated for both methods: and compared with ESPEN consensus. Of 102 eligible in-patients, 88 fulfilled inclusion criteria and were identified as "at risk" by MNA-SF. Malnutrition diagnosis was confirmed in 11.6% and 10.5% of the patients using classical methods,whereas 19.3% were malnourished according to the ESPEN criteria. Combined with low albumin levels, the diagnosis showed 57.9% sensitivity, 64.5% specificity, 85.9% negative predictive value,0.63 accuracy (fair validity, low range), and kappa index of 0.163 (poor ESPEN agreement). The combination of MNA-SF, low albumin, and clinical malnutrition showed 52.6% sensitivity, 88.3% specificity, 88.3%negative predictive value, and 0.82 accuracy (fair validity, low range), and kappa index of 0.43 (fair ESPEN agreement). Malnutrition was almost twice as prevalent when diagnosed by the ESPEN consensus, compared to classical assessment methods: Classical methods: showed fair validity and poor agreement with the ESPEN consensus in assessing malnutrition in geriatric postacute care. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Comparison of Alcohol Use Disorder Screens During College Athlete Pre-Participation Evaluations.

    PubMed

    Majka, Erek; Graves, Travis; Diaz, Vanessa A; Player, Marty S; Dickerson, Lori M; Gavin, Jennifer K; Wessell, Andrea

    2016-05-01

    The US Preventive Services Task Force (USPSTF) recommends screening adults for alcohol misuse, a challenge among young adults who may not have regular primary care. The pre-participation evaluation (PPE) provides an opportunity for screening, but traditional screening tools require extra time in an already busy visit. The objective of this study was to compare the 10-item Alcohol Use Disorders Identification Test (AUDIT) with a single-question alcohol misuse screen in a population of college-aged athletes. This cross-sectional study was performed during an athletic PPE clinic at a college in the Southeastern United States among athletes ages 18 years and older. Written AUDIT and single-question screen "How many times in the past year have you had X or more drinks in a day?" (five for men, four for women) asked orally were administered to each participant. Sensitivity, specificity, and positive and negative predictive values for the single-question screen were compared to AUDIT. A total of 225 athletes were screened; 60% were female; 29% screened positive by AUDIT; 59% positive by single-question instrument. Males were more likely to screen positive by both methods. Compared to the AUDIT, the brief single-question screen had 92% sensitivity for alcohol misuse and 55% specificity. The negative predictive value of the single-question screen was 95% compared to AUDIT. A single-question screen for alcohol misuse in college-aged athletes had a high sensitivity and negative predictive value compared to the more extensive AUDIT screen. Ease of administration of this screening tool is ideal for use within the pre-participation physical among college-aged athletes who may not seek regular medical care.

  17. Assessing the Psychometric Properties of Two Food Addiction Scales

    PubMed Central

    Lemeshow, Adina; Gearhardt, Ashley; Genkinger, Jeanine; Corbin, William R.

    2016-01-01

    Background While food addiction is well accepted in popular culture and mainstream media, its scientific validity as an addictive behavior is still under investigation. This study evaluated the reliability and validity of the Yale Food Addiction Scale and Modified Yale Food Addiction Scale using data from two community-based convenience samples. Methods We assessed the internal and test-retest reliability of the Yale Food Addiction Scale and Modified Yale Food Addiction Scale, and estimated the sensitivity and negative predictive value of the Modified Yale Food Addiction Scale using the Yale Food Addiction Scale as the benchmark. We calculated Cronbach’s alphas and 95% confidence intervals (CIs) for internal reliability and Cohen’s Kappa coefficients and 95% CIs for test-retest reliability. Results Internal consistency (n=232) was marginal to good, ranging from α=0.63 to 0.84. The test-retest reliability (n=45) for food addiction diagnosis was substantial, with Kappa=0.73 (95% CI, 0.48–0.88) (Yale Food Addiction Scale) and 0.79 (95% CI, 0.66–1.00) (Modified Yale Food Addiction Scale). Sensitivity and negative predictive value for classifying food addiction status were excellent: compared to the Yale Food Addiction Scale, the Modified Yale Food Addiction Scale’s sensitivity was 92.3% (95% CI, 64%–99.8%), and the negative predictive value was 99.5% (95% CI, 97.5%–100%). Conclusions Our analyses suggest that the Modified Yale Food Addiction Scale may be an appropriate substitute for the Yale Food Addiction Scale when a brief measure is needed, and support the continued use of both scales to investigate food addiction. PMID:27623221

  18. Frailty screening methods for predicting outcome of a comprehensive geriatric assessment in elderly patients with cancer: a systematic review.

    PubMed

    Hamaker, Marije E; Jonker, Judith M; de Rooij, Sophia E; Vos, Alinda G; Smorenburg, Carolien H; van Munster, Barbara C

    2012-10-01

    Comprehensive geriatric assessment (CGA) is done to detect vulnerability in elderly patients with cancer so that treatment can be adjusted accordingly; however, this process is time-consuming and pre-screening is often used to identify fit patients who are able to receive standard treatment versus those in whom a full CGA should be done. We aimed to assess which of the frailty screening methods available show the best sensitivity and specificity for predicting the presence of impairments on CGA in elderly patients with cancer. We did a systematic search of Medline and Embase, and a hand-search of conference abstracts, for studies on the association between frailty screening outcome and results of CGA in elderly patients with cancer. Our search identified 4440 reports, of which 22 publications from 14 studies, were included in this Review. Seven different frailty screening methods were assessed. The median sensitivity and specificity of each screening method for predicting frailty on CGA were as follows: Vulnerable Elders Survey-13 (VES-13), 68% and 78%; Geriatric 8 (G8), 87% and 61%; Triage Risk Screening Tool (TRST 1+; patient considered frail if one or more impairments present), 92% and 47%, Groningen Frailty Index (GFI) 57% and 86%, Fried frailty criteria 31% and 91%, Barber 59% and 79%, and abbreviated CGA (aCGA) 51% and 97%. However, even in case of the highest sensitivity, the negative predictive value was only roughly 60%. G8 and TRST 1+ had the highest sensitivity for frailty, but both had poor specificity and negative predictive value. These findings suggest that, for now, it might be beneficial for all elderly patients with cancer to receive a complete geriatric assessment, since available frailty screening methods have insufficient discriminative power to select patients for further assessment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Hub qualitative blood culture is useful for diagnosis of catheter-related infections in critically ill patients.

    PubMed

    Tanguy, Michèle; Seguin, Philippe; Laviolle, Bruno; Desbordes, Laurent; Mallédant, Yannick

    2005-05-01

    To assess clinical safety and accuracy of qualitative blood culture drawn through the hub for ruling out catheter-related infection (CRI). Prospective observational study in a surgical intensive care unit. All patients with sepsis of unknown origin and possibly due to a CRI. Blood culture drawn through a central venous catheter (CVC) just before the catheter was cultured. In 126 patients we investigated 135 cases of sepsis of unknown origin. Using a clinical and bacteriological approach as the reference, the performance of the CVC blood culture was evaluated by the calculation of sensitivity, specificity, and positive and negative predictive values. When CVC blood culture was positive, the time to positivity was considered. Using standard definitions, seven CRIs were diagnosed. CVC blood culture identified five CRIs including the three episodes of catheter-related bacteremia. The method missed two coagulase-negative staphylococcus CRIs without bacteremia. Thirteen false-positive results occurred, including seven bacteremias from a distant source. The CVC blood culture had a sensitivity of 71% (CI 30-95%), specificity of 90% (CI 83-94%), negative predictive value of 98% (CI 93-100%), and positive predictive value of 28% (CI 11-54%). In cases of catheter-related bacteremia the time to positivity of CVC blood culture was 24 h or less. Negative CVC blood culture at 24 h seems useful for management of CVC in selected critically ill surgical patients developing a clinical sepsis. The subsequent risk of catheter-related bacteremia cannot be excluded advocating for an uninterrupted clinical and bacteriological survey.

  20. [Relevance of proton spin tomographic meniscus diagnosis in correlation with arthroscopy].

    PubMed

    Imhoff, A; Buess, E; Hodler, J; Schreiber, A

    1994-04-01

    Arthroscopy of the menisci is considered the gold standard by which all noninvasive imaging procedures of the knee are measured. In a prospective study we evaluated the use of MRI in 50 patients in whom a disorder of the meniscus was suspected clinically; this was followed by an arthroscopic examination by an experienced arthroscopist. The MR studies were performed after clinical evaluation and were interpreted by an experienced radiologist, who had no knowledge of the clinical findings. The accuracy of the diagnosis from MRI was 78% for the medial meniscus (sensitivity 79% and specificity 78%) and 94% for the lateral meniscus (sensitivity 50% and specificity 98%). The average age of the patients was 34 years, with a range of 3-73 years. The imaging studies revealed 9 false-positive tests and suggested that the meniscus was either degenerated or torn in the horizontal plane. In all 9 menisci the abnormal MR imaging signal was limited to the posterior horns. The positive predictive value was 59% and the negative predictive value was 94%, representing a moderate level of diagnostic certainty both in patients who had a positive result and in those who had a negative result. The high predictive negative value of MRI indicates that a negative MRI is quite reliable for meniscal lesions. The problem areas in MR imaging are the popliteal tendon sheath and the transverse ligament. This ligament is seen in association with a large branch of the lateral inferior geniculate artery and may be mistaken for a grade 3 signal intensity in the anterior horn of the lateral meniscus.

  1. Magnifying endoscopy for the diagnosis of specialized intestinal metaplasia in short-segment Barrett's esophagus.

    PubMed

    Ham, Nam Seok; Jang, Jae Young; Ryu, Sung Woo; Kim, Ji Hye; Park, Eui Ju; Lee, Woong Cheul; Shim, Kwang Yeun; Jeong, Soung Won; Kim, Hyun Gun; Lee, Tae Hee; Jeon, Sung Ran; Cho, Jun Hyung; Cho, Joo Young; Jin, So Young; Lee, Ji Sung

    2013-11-07

    To determine whether magnified observation of short-segment Barrett's esophagus (BE) is useful for the detection of specialized intestinal metaplasia (SIM). Thirty patients with suspected short-segment BE underwent magnifying endoscopy up to × 80. The magnified images were analyzed with respect to their pit-patterns, which were simultaneously classified into five epithelial types [I (small round), II (straight), III (long oval), IV (tubular), V (villous)] by Endo's classification. Then, a 0.5% solution of methylene blue (MB) was sprayed over columnar mucosa. The patterns of the magnified image and MB staining were analyzed. Biopsies were obtained from the regions previously observed by magnifying endoscopy and MB chromoendoscopy. Three of five patients with a type V (villous) epithelial pattern had SIM, whereas 21 patients with a non-type V epithelial patterns did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of pit-patterns in detecting SIM were 100%, 91.3%, 92.3%, 60% and 100%, respectively (P = 0.004). Three of the 12 patients with positive MB staining had SIM, whereas 14 patients with negative MB staining did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MB staining in detecting SIM were 100%, 60.9%, 65.4%, 25% and 100%, respectively (P = 0.085). The specificity and accuracy of pit-pattern evaluation were significantly superior compared with MB staining for detecting SIM by comparison with the exact McNemar's test (P = 0.0391). The magnified observation of a short-segment BE according to the mucosal pattern and its classification can be predictive of SIM.

  2. CorVue algorithm efficacy to predict heart failure in real life: Unnecessary and potentially misleading information?

    PubMed

    Palfy, Julia Anna; Benezet-Mazuecos, Juan; Milla, Juan Martinez; Iglesias, Jose Antonio; de la Vieja, Juan Jose; Sanchez-Borque, Pepa; Miracle, Angel; Rubio, Jose Manuel

    2018-06-01

    Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic) has been widely studied, CorVue™ algorithm (St. Jude Medical) long term efficacy has not been systematically evaluated in a "real life" cohort. CorVue™ was activated in ICD/CRT-D patients to store information about ITI measures. Clinical events (new episodes of HF requiring treatment and hospitalizations) and CorVue™ data were recorded every three months. Appropriate CorVue™ detection for HF was considered if it occurred in the four prior weeks to the clinical event. 53 ICD/CRT-D (26 ICD and 27 CRT-D) patients (67±1 years-old, 79% male) were included. Device position was subcutaneous in 28 patients. At inclusion, mean LVEF was 25±7% and 27 patients (51%) were in NYHA class I, 18 (34%) class II and 8 (15%) class III. After a mean follow-up of 17±9 months, 105 ITI drops alarms were detected in 32 patients (60%). Only six alarms were appropriate (true positive) and required hospitalization. Eighteen patients (34%) presented 25 clinical episodes (12 hospitalizations and 13 ER/ambulatory treatment modifications). Nineteen of these clinical episodes (76%) remained undetected by the CorVue™ (false negative). Sensitivity of CorVue™ resulted in 24%, specificity was 70%, positive predictive value of 6% and negative predictive value of 93%. CorVue™ showed a low sensitivity to predict HF events. Therefore, routinely activation of this algorithm could generate misleading information. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Comparison of ultrasound versus computed tomography for the detection of kidney stones in the pediatric population: a clinical effectiveness study.

    PubMed

    Roberson, Nathaniel P; Dillman, Jonathan R; O'Hara, Sara M; DeFoor, William R; Reddy, Pramod P; Giordano, Richard M; Trout, Andrew T

    2018-07-01

    The incidence of pediatric nephrolithiasis in the United States is increasing. There is a paucity of literature comparing the diagnostic performance of computed ultrasound (US) to tomography (CT) in the pediatric population. To determine the diagnostic performance of renal US for nephrolithiasis in children using a clinical effectiveness approach. Institutional review board approval with a waiver of informed consent was obtained for this retrospective, HIPAA-complaint investigation. Billing records and imaging reports were used to identify children (≤18 years old) evaluated for nephrolithiasis by both US and unenhanced CT within 24 h between March 2012 and March 2017. Imaging reports were reviewed for presence, number, size and location of kidney stones. Diagnostic performance of US (reference standard=CT) was calculated per renal unit (left/right kidney) and per renal sector (four sectors per kidney). For sector analysis, US was considered truly positive if a stone was identified at CT in the same or an adjacent sector. There were 68 renal stones identified by CT in 30/69 patients (43%). Mean patient age was 14.7±3.6 years, and 35 were boys. For detecting nephrolithiasis in any kidney, US was 66.7% (48.8-80.8%) sensitive and 97.4% (86.8-99.9%) specific (positive predictive value=95.2% [77.3-99.8%], negative predictive value=79.2% [65.7-88.3%], positive likelihood ratio=26.0). Per renal sector, US was 59.7% (46.7-71.4%) sensitive and 97.4% (95.5-98.5%) specific (positive predictive value=72.3% [58.2-83.1%], negative predictive value=95.4% [93.2-96.9%], positive likelihood ratio=22.5). Of the 30 stones not detected by US, only 3 were >3 mm at CT. In clinical practice, US has high specificity for detecting nephrolithiasis in children but only moderate sensitivity and false negatives are common.

  4. The diagnostic accuracy of physical examination compared to lung ultrasound for determining lung congestion in hemodialysis patients who have reached their dry weight

    NASA Astrophysics Data System (ADS)

    Rahardjo, K. D.; Dharmaeizar; Nainggolan, G.; Harimurti, K.

    2017-08-01

    Research has shown that hemodialysis patients with lung congestion have high morbidity and mortality. Patients were assumed to be free of lung congestion if they had reached their post-dialysis dry weight. Most often, to determine if the patient was free of lung congestion, physical examination was used. However, the accuracy of physical examination in detecting lung congestion has not been established. To compare the capabilities of physical examination and lung ultrasound in detection of lung congestion, cross-sectional data collection was conducted on hemodialysis patients. Analysis was done to obtain proportion, sensitivity, specificity, positive predictive value, negative predictive value, and positive likelihood ratio. Sixty patients participated in this study. The inter observer variation of 20 patients revealed a kappa value of 0.828. When all 60 patients were taken into account, we found that 36 patients (57.1%) had lung congestion. Mild lung congestion was found in 24 (38.1%), and 12 (19%) had a moderate degree of congestion. In the analysis comparing jugular venous pressure to lung ultrasound, we found that sensitivity was 0.47 (0.31-0.63), specificity was 0.73 (0.54-0.86), positive predictive value (PPV) was 0.51 (0.36-0.67), negative predictive value (NPV) was 0.70 (0.49-0.84), positive likelihood ratio (PLR) was 1.75 (0.88-3.47), and the negative likelihood ratio (NLR) was 0.72 (0.47-1.12). In terms of lung auscultation, we found that sensitivity was 0.56 (0.39-0.71), specificity was 0.54 (0.35-0.71), PPV was 0.61 (0.44-0.76), NPV was 0.48 (0.31-0.66), PLR was 1.21 (0.73-2.0), and NLR was 0.82 (0.49-1.38). The results of our study showed that jugular venous distention and lung auscultation examination are not reliable means of detecting lung congestion.

  5. Direct detection of methicillin resistance in Staphylococcus aureus in blood culture broth by use of a penicillin binding protein 2a latex agglutination test.

    PubMed

    Qian, Qinfang; Venkataraman, Lata; Kirby, James E; Gold, Howard S; Yamazumi, Toshiaki

    2010-04-01

    We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.

  6. Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.

    PubMed

    Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K

    2017-08-01

    The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Reliability of fluorescein dye disappearance test in assessment of adults with nasolacrimal duct obstruction.

    PubMed

    Kashkouli, Mohsen Bahmani; Mirzajani, Hoora; Jamshidian-Tehrani, Mansooreh; Pakdel, Farzad; Nojomi, Marzieh; Aghaei, Gholam-Hossein

    2013-01-01

    To evaluate the role of fluorescein dye disappearance test (FDDT) in assessment of adults with primary acquired nasolacrimal duct obstruction (PANDO) and its correlation with age and severity of epiphora. In a prospective, cross-sectional comparative study, FDDT at 2 (2-FDDT), 5 (5-FDDT), and 10 (10-FDDT) minutes were performed in 58 eyes of 58 patients with PANDO (case) and 58 eyes of 58 subjects without epiphora (control) between 2008 and 2010. Exclusion criteria were any disease, trauma, or medications that might have an effect on tear drainage system. Patients with functional or incomplete obstruction and upper lacrimal drainage system obstruction were excluded in the case group. FDDT and severity of epiphora were graded. Case and control groups were matched. 2-FDDT showed a sensitivity of 82.8%, specificity of 91.4%, positive predictive value of 90.6%, and negative predictive value of 84.1%. Sensitivity and negative predictive value decreased to 71.1% and 78.6% in 5-FDDT. 5-FDDT specificity and positive predictive value, however, increased to 94.8% and 93.5%, respectively. There was no statistically significant correlation between severity of epiphora and age with FDDT. FDDT is a simple, reliable, and highly specific test in assessment of adults with PANDO.

  8. Diagnostic value of contrast-enhanced ultrasound in thyroid nodules with calcification.

    PubMed

    Jiang, Jue; Shang, Xu; Wang, Hua; Xu, Yong-Bo; Gao, Ya; Zhou, Qi

    2015-03-01

    The aim of this study was to investigate the diagnostic values of conventional ultrasound and contrast-enhanced ultrasound (CEUS) in benign and malignant thyroid nodules with calcification. Conventional ultrasound and CEUS were performed in 122 patients with thyroid nodules with calcification. The thyroid nodules were characterized as benign or malignant by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of the two imaging methods were determined. The area under the receiver operating characteristics curve (AUC) was used to assess the diagnostic values of the two imaging methods. In 122 cases of thyroid nodules with calcification, 73 benign nodules and 49 malignant nodules were verified by pathological diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate of conventional ultrasound were 50%, 77%, 59%, 69%, and 66%, respectively, and those of CEUS were 90%, 92%, 88%, 93%, and 91%, respectively. There were significant differences between the two imaging methods. AUCs of conventional ultrasound and CEUS were 0.628 ± 0.052 and 0.908 ± 0.031, suggesting low and high diagnostic values, respectively. CEUS has high diagnostic values, being significantly greater than those of conventional ultrasound, in differential diagnosis of benign and malignant thyroid nodules with calcification. Copyright © 2014. Published by Elsevier Taiwan.

  9. Evaluation of two real time PCR assays for the detection of bacterial DNA in amniotic fluid.

    PubMed

    Girón de Velasco-Sada, Patricia; Falces-Romero, Iker; Quiles-Melero, Inmaculada; García-Perea, Adela; Mingorance, Jesús

    2018-01-01

    The aim of this study was to evaluate two non-commercial Real-Time PCR assays for the detection of microorganisms in amniotic fluid followed by identification by pyrosequencing. We collected 126 amniotic fluids from 2010 to 2015 for the evaluation of two Real-Time PCR assays for detection of bacterial DNA in amniotic fluid (16S Universal PCR and Ureaplasma spp. specific PCR). The method was developed in the Department of Microbiology of the University Hospital La Paz. Thirty-seven samples (29.3%) were positive by PCR/pyrosequencing and/or culture, 4 of them were mixed cultures with Ureaplasma urealyticum. The Universal 16S Real-Time PCR was compared with the standard culture (81.8% sensitivity, 97.4% specificity, 75% positive predictive value, 98% negative predictive value). The Ureaplasma spp. specific Real-Time PCR was compared with the Ureaplasma/Mycoplasma specific culture (92.3% sensitivity, 89.4% specificity, 50% positive predictive value, 99% negative predictive value) with statistically significant difference (p=0.005). Ureaplasma spp. PCR shows a rapid response time (5h from DNA extraction until pyrosequencing) when comparing with culture (48h). So, the response time of bacteriological diagnosis in suspected chorioamnionitis is reduced. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Combined panel of serum human tissue kallikreins and CA-125 for the detection of epithelial ovarian cancer.

    PubMed

    Koh, Stephen Chee Liang; Huak, Chan Yiong; Lutan, Delfi; Marpuang, Johny; Ketut, Suwiyoga; Budiana, Nyoma Gede; Saleh, Agustria Zainu; Aziz, Mohamad Farid; Winarto, Hariyono; Pradjatmo, Heru; Hoan, Nguyen Khac Han; Thanh, Pham Viet; Choolani, Mahesh

    2012-07-01

    To determine the predictive accuracy of the combined panels of serum human tissue kallikreins (hKs) and CA-125 for the detection of epithelial ovarian cancer. Serum specimens collected from 5 Indonesian centers and 1 Vietnamese center were analyzed for CA-125, hK6, and hK10 levels. A total of 375 specimens from patients presenting with ovarian tumors, which include 156 benign cysts, 172 epithelial ovarian cancers (stage I/II, n=72; stage III/IV, n=100), 36 germ cell tumors and 11 borderline tumors, were included in the study analysis. Receiver operating characteristic analysis were performed to determine the cutoffs for age, CA-125, hK6, and hK10. Sensitivity, specificity, negative, and positive predictive values were determined for various combinations of the biomarkers. The levels of hK6 and hK10 were significantly elevated in ovarian cancer cases compared to benign cysts. Combination of 3 markers, age/CA-125/hk6 or CA-125/hk6/hk10, showed improved specificity (100%) and positive predictive value (100%) for prediction of ovarian cancer, when compared to the performance of single markers having 80-92% specificity and 74-87% positive predictive value. Four-marker combination, age/CA-125/hK6/hK10 also showed 100% specificity and 100% positive predictive value, although it demonstrated low sensitivity (11.9%) and negative predictive value (52.8%). The combination of human tissue kallikreins and CA-125 showed potential for improving prediction of epithelial ovarian cancer in patients presenting with ovarian tumors.

  11. A novel clinical index for the assessment of RVD in acute pulmonary embolism: Blood pressure index.

    PubMed

    Ates, Hale; Ates, Ihsan; Kundi, Harun; Arikan, Mehmet Fettah; Yilmaz, Fatma Meric

    2017-10-01

    This study aims to investigate the role of the blood pressure index (BPI), which is a new index that we developed, in detection of right ventricular dysfunction (RVD) in acute pulmonary embolism (APE). A total of 539 patients, (253 males and 286 females), diagnosed with APE using computer tomography pulmonary angiography were included in the study. The BPI was obtained by dividing systolic blood pressure (SBP) by diastolic blood pressure (DBP). Mean DBP (75±11mmHg vs 63±15mmHg; p<0.001, respectively) was found to be higher in RVD patients compared to those without RVD, whereas BPI (1.5±0.1 vs 1.9±0.2; p<0.001, respectively) was lower. Examining the performance of BPI in prediction of RVD using receiver operating characteristic curve analysis (area under curve±SE=0.975±0.006; p<0.001), it was found that BPI could predict RVD with very high sensitivity (92.8%) and specificity (100%) and had a positive predictive value of 100% and a negative predictive value of 42.1%. According to the analysis, the highest youden index for the optimal prediction value was found to be 0.478 and the BPI≤1.4 was found to predict mortality 68.6% sensitivity and 80.8% specificity (Area under curve±SE=0.777±0.051; p<0.001). We found that BPI was an index with high positive predictive value and low negative predictive value in detection of RVD. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Black Hole Sign: Novel Imaging Marker That Predicts Hematoma Growth in Patients With Intracerebral Hemorrhage.

    PubMed

    Li, Qi; Zhang, Gang; Xiong, Xin; Wang, Xing-Chen; Yang, Wen-Song; Li, Ke-Wei; Wei, Xiao; Xie, Peng

    2016-07-01

    Early hematoma growth is a devastating neurological complication after intracerebral hemorrhage. We aim to report and evaluate the usefulness of computed tomography (CT) black hole sign in predicting hematoma growth in patients with intracerebral hemorrhage. Patients with intracerebral hemorrhage were screened for the presence of CT black hole sign on admission head CT performed within 6 hours after onset of symptoms. The black hole sign was defined as hypoattenuatting area encapsulated within the hyperattenuating hematoma with a clearly defined border. The sensitivity, specificity, and positive and negative predictive values of CT black hole sign in predicting hematoma expansion were calculated. Logistic regression analyses were used to assess the presence of the black hole sign and early hematoma growth. A total of 206 patients were enrolled. Black hole sign was found in 30 (14.6%) of 206 patients on the baseline CT scan. The black hole sign was more common in patients with hematoma growth (31.9%) than those without hematoma growth (5.8%; P<0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of back hole sign in predicting early hematoma growth were 31.9%, 94.1%, 73.3%, and 73.2%, respectively. The time-to-admission CT scan, baseline hematoma volume, and the presence of black hole sign on admission CT independently predict hematoma growth in multivariate model. The CT black hole sign could be used as a simple and easy-to-use predictor for early hematoma growth in patients with intracerebral hemorrhage. © 2016 American Heart Association, Inc.

  13. The diagnostic value of troponin T testing in the community setting.

    PubMed

    Planer, David; Leibowitz, David; Paltiel, Ora; Boukhobza, Rina; Lotan, Chaim; Weiss, Teddy A

    2006-03-08

    Many patients presenting with chest pain to their family physician are referred to the emergency room, in part, due to lack of accurate objective diagnostic tools. This study aimed to assess the diagnostic value of bedside troponin T kit testing in patients presenting with chest pain to their family physician. Prospective, multi-center study. Consecutive subjects with chest pain were recruited from 44 community clinics in Jerusalem. Following clinical assessment by the family physician, qualitative troponin kit testing was performed. Patients with a negative clinical assessment and negative troponin kit were sent home and all others were referred to the emergency room. The final diagnosis at the time of hospital discharge was recorded and telephone follow up was performed after 60 days. Positive predictive value, negative predictive value, sensitivity and specificity of troponin kit for myocardial infarction diagnosis and of family physician for hospitalization, were assessed. Of 392 patients enrolled, 349 (89%) were included in the final analysis. The prevalence of myocardial infarction was 1.7%. The positive and negative predictive values of the troponin kit for myocardial infarction diagnosis were 100% and 99.7%, respectively. The positive and negative predictive values of the family physician's assessment to predict hospitalization were 41.4% and 94.1%, respectively. Troponin kit testing is an important tool to assist the family physician in the assessment of patients with chest pain in the community setting. Troponin kit testing may identify otherwise undiagnosed cases of myocardial infarctions, and reduce unnecessary referrals to the emergency room.

  14. Clinical Utility of Urinary Cytology to Detect BK Viral Nephropathy.

    PubMed

    Nankivell, Brian J; Renthawa, Jasveen; Jeoffreys, Neisha; Kable, Kathy; O'Connell, Philip J; Chapman, Jeremy R; Wong, Germaine; Sharma, Raghwa N

    2015-08-01

    Reactivation of BK polyoma virus can result in destructive viral allograft nephropathy (BKVAN) with limited treatment options. Screening programs using surrogate markers of viral replication are important preventive strategies, guiding immunosuppression reduction. We prospectively evaluated the diagnostic test performance of urinary decoy cells and urinary SV40T immunochemistry of exfoliated cells, to screen for BKVAN, (defined by reference histology with SV40 immunohistochemistry, n = 704 samples), compared with quantitative viremia, from 211 kidney and 141 kidney-pancreas transplant recipients. The disease prevalence of BKVAN was 2.6%. Decoy cells occurred in 95 of 704 (13.5%) samples, with a sensitivity of 66.7%, specificity of 88.6%, positive predictive value (PPV) of 11.7%, and negative predictive value of 98.5% to predict histologically proven BKVAN. Quantification of decoy cells improved the PPV to 32.1% (10 ≥ cells threshold). Immunohistochemical staining of urinary exfoliated cells for SV40T improved sensitivity to 85.7%, detecting atypical or degenerate infected cells (specificity of 92.3% and PPV of 33.3%), but was hampered by technical failures. Viremia occurred in 90 of 704 (12.8%) with sensitivity of 96.3%, specificity of 90.3%, PPV of 31.5%, and negative predictive value of 99.8%. The receiver-operator curve performance of quantitative viremia surpassed decoy cells (area under the curve of 0.95 and 0.79, respectively, P = 0.0018 for differences). Combining decoy cell and BK viremia in a diagnostic matrix improved prediction of BKVAN and diagnostic risk stratification, especially for high-level positive results. Although quantified decoy cells are acceptable surrogate markers of BK viral replication with unexceptional test performances, quantitative viremia displayed superior test characteristics and is suggested as the screening test of choice.

  15. Can administrative health utilisation data provide an accurate diabetes prevalence estimate for a geographical region?

    PubMed

    Chan, Wing Cheuk; Papaconstantinou, Dean; Lee, Mildred; Telfer, Kendra; Jo, Emmanuel; Drury, Paul L; Tobias, Martin

    2018-05-01

    To validate the New Zealand Ministry of Health (MoH) Virtual Diabetes Register (VDR) using longitudinal laboratory results and to develop an improved algorithm for estimating diabetes prevalence at a population level. The assigned diabetes status of individuals based on the 2014 version of the MoH VDR is compared to the diabetes status based on the laboratory results stored in the Auckland regional laboratory result repository (TestSafe) using the New Zealand diabetes diagnostic criteria. The existing VDR algorithm is refined by reviewing the sensitivity and positive predictive value of the each of the VDR algorithm rules individually and as a combination. The diabetes prevalence estimate based on the original 2014 MoH VDR was 17% higher (n = 108,505) than the corresponding TestSafe prevalence estimate (n = 92,707). Compared to the diabetes prevalence based on TestSafe, the original VDR has a sensitivity of 89%, specificity of 96%, positive predictive value of 76% and negative predictive value of 98%. The modified VDR algorithm has improved the positive predictive value by 6.1% and the specificity by 1.4% with modest reductions in sensitivity of 2.2% and negative predictive value of 0.3%. At an aggregated level the overall diabetes prevalence estimated by the modified VDR is 5.7% higher than the corresponding estimate based on TestSafe. The Ministry of Health Virtual Diabetes Register algorithm has been refined to provide a more accurate diabetes prevalence estimate at a population level. The comparison highlights the potential value of a national population long term condition register constructed from both laboratory results and administrative data. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Nonimmediate hypersensitivity reactions to iodinated contrast media.

    PubMed

    Gómez, Enrique; Ariza, Adriana; Blanca-López, Natalia; Torres, Maria J

    2013-08-01

    To provide a detailed analysis of the latest findings on the mechanisms underlying the nonimmediate reactions to iodinated contrast media and comment on the recent advances in diagnosis, focusing on the roles of the skin test, drug provocation test (DPT), and lymphocyte transformation test (LTT). Several studies have reported new findings supporting an important role for T-lymphocytes in the nonimmediate reactions to iodinated contrast media. The LTT has been used as an in-vitro tool for diagnosis, but with variable results. However, the inclusion of autologous monocyte-derived dendritic cells as professional antigen-presenting cells has improved the sensitivity of this test. Regarding in-vivo diagnosis, although skin testing has been routine, it has now been shown that its sensitivity and negative predictive value are low. Recent studies have demonstrated that the DPT is a well tolerated and useful procedure that is necessary to confirm the diagnosis of nonimmediate hypersensitivity reactions to iodinated contrast media. Nonimmediate reactions to contrast media are usually T-cell mediated. Diagnosis is based on skin testing, although its sensitivity and negative predictive value are not optimal. Consequently, drug provocation testing is often needed to confirm the diagnosis and also to seek alternative contrast media that can be tolerated.

  17. Diagnosis accuracy of two vision screeners for visual health surveillance of workers who use video display terminals

    PubMed Central

    Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena

    2016-01-01

    Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039

  18. Effects of heat stress and insulin sensitizers on pig adipose tissue

    USDA-ARS?s Scientific Manuscript database

    Heat stress (HS) negatively impacts several swine production variables, including carcass fat quality. Pigs reared in HS have more adipose tissue than energetically predicted, explainable by HS-induced hyperinsulinemia. Study objectives were to evaluate insulin’s role in altering fat characteristics...

  19. A computational approach to negative priming

    NASA Astrophysics Data System (ADS)

    Schrobsdorff, H.; Ihrke, M.; Kabisch, B.; Behrendt, J.; Hasselhorn, M.; Herrmann, J. Michael

    2007-09-01

    Priming is characterized by a sensitivity of reaction times to the sequence of stimuli in psychophysical experiments. The reduction of the reaction time observed in positive priming is well-known and experimentally understood (Scarborough et al., J. Exp. Psycholol: Hum. Percept. Perform., 3, pp. 1-17, 1977). Negative priming—the opposite effect—is experimentally less tangible (Fox, Psychonom. Bull. Rev., 2, pp. 145-173, 1995). The dependence on subtle parameter changes (such as response-stimulus interval) usually varies. The sensitivity of the negative priming effect bears great potential for applications in research in fields such as memory, selective attention, and ageing effects. We develop and analyse a computational realization, CISAM, of a recent psychological model for action decision making, the ISAM (Kabisch, PhD thesis, Friedrich-Schiller-Universitat, 2003), which is sensitive to priming conditions. With the dynamical systems approach of the CISAM, we show that a single adaptive threshold mechanism is sufficient to explain both positive and negative priming effects. This is achieved by comparing results obtained by the computational modelling with experimental data from our laboratory. The implementation provides a rich base from which testable predictions can be derived, e.g. with respect to hitherto untested stimulus combinations (e.g. single-object trials).

  20. Evaluation of the hydrometer for testing immunoglobulin G1 concentrations in Holstein colostrum.

    PubMed

    Pritchett, L C; Gay, C C; Hancock, D D; Besser, T E

    1994-06-01

    Hydrometer measurement in globulin and IgG1 concentration measured by the radial immunodiffusion technique were compared for 915 samples of first milking colostrum from Holstein cows. Least squares analysis of the relationship between hydrometer measurement and IgG1 concentration was improved by log transformation of IgG1 concentration and resulted in a significant linear relationship between hydrometer measurement and log10 IgG1 concentration; r2 = .469. At 50 mg of globulin/ml of colostrum, the recommended hydrometer cutoff point for colostrum selection, the sensitivity of the hydrometer as a test of IgG1 concentration in Holstein colostrum was 26%, and the negative predictive value was 67%. The negative predictive value and sensitivity of the hydrometer as a test of IgG1 in Holstein colostrum was improved, and the cost of misclassification of colostrum was minimized, when the cutoff point for colostrum selection was increased above the recommended 50 mg/ml.

  1. Comparison of the BD GeneOhm Methicillin-Resistant Staphylococcus aureus (MRSA) PCR Assay to Culture by Use of BBL CHROMagar MRSA for Detection of MRSA in Nasal Surveillance Cultures from Intensive Care Unit Patients▿

    PubMed Central

    Snyder, James W.; Munier, Gina K.; Johnson, Charles L.

    2010-01-01

    This study compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay to culture by the use of BBL CHROMagar MRSA for the detection of MRSA in 627 nasal surveillance specimens collected from intensive care unit (ICU) patients. The PCR assay had a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 96.7%, 70.3%, and 100%, respectively. Nine of 19 false-positive PCR specimens grew methicillin-susceptible S. aureus (MSSA) from broth enrichment culture, of which two demonstrated evidence of mecA gene dropout. Compared to culture by the use of BBL CHROMagar MRSA, the BD GeneOhm MRSA PCR assay demonstrated sensitivity and specificity above 95% for the detection of MRSA nasal colonization and provided shorter turnaround time in generating positive and negative final results. PMID:20181916

  2. Transcutaneous measurement of hyperbilirubinaemia: comparison of the Minolta jaundice meter and the Ingram icterometer.

    PubMed

    Bilgen, H; Ince, Z; Ozek, E; Bekiroglu, N; Ors, R

    1998-12-01

    The effectiveness of two different non-invasive transcutaneous bilirubin measurement devices was compared with serum bilirubin levels in 96 healthy newborns. Transcutaneous measurements were obtained with the Minolta Air Shields jaundice meter and the Ingram icterometer and serum bilirubin levels were determined by a direct spectrophotometric method (Bilitron 444). A linear correlation existed between serum bilirubin values and the readings on both the Minolta jaundice meter (r = 0.83) and the Ingram icterometer (r = 0.78). The Kappa coefficient was 0.66. the sensitivity, specificity and positive and negative predictive values were 100%, 56%, 33% and 100% for the Minolta jaundice meter and 100%, 48%, 29% and 100% for the Ingram icterometer, respectively. The high sensitivity and negative predictive value of both devices render them suitable for screening neonatal hyperbilirubinaemia. However, because of its low cost, the Ingram icterometer is preferable to the more complex and expensive Minolta jaundice meter, especially in countries with a high birth rate, such as Turkey.

  3. Prediction of uncomplicated pregnancies in obese women: a prospective multicentre study.

    PubMed

    Vieira, Matias C; White, Sara L; Patel, Nashita; Seed, Paul T; Briley, Annette L; Sandall, Jane; Welsh, Paul; Sattar, Naveed; Nelson, Scott M; Lawlor, Debbie A; Poston, Lucilla; Pasupathy, Dharmintra

    2017-11-03

    All obese pregnant women are considered at equal high risk with respect to complications in pregnancy and birth, and are commonly managed through resource-intensive care pathways. However, the identification of maternal characteristics associated with normal pregnancy outcomes could assist in the management of these pregnancies. The present study aims to identify the factors associated with uncomplicated pregnancy and birth in obese women, and to assess their predictive performance. Data form obese women (BMI ≥ 30 kg/m 2 ) with singleton pregnancies included in the UPBEAT trial were used in this analysis. Multivariable logistic regression was used to identify sociodemographic, clinical and biochemical factors at 15 +0 to 18 +6 weeks' gestation associated with uncomplicated pregnancy and birth, defined as delivery of a term live-born infant without antenatal or labour complications. Predictive performance was assessed using area under the receiver operating characteristic curve (AUROC). Internal validation and calibration were also performed. Women were divided into fifths of risk and pregnancy outcomes were compared between groups. Sensitivity, specificity, and positive and negative predictive values were calculated using the upper fifth as the positive screening group. Amongst 1409 participants (BMI 36.4, SD 4.8 kg/m 2 ), the prevalence of uncomplicated pregnancy and birth was 36% (505/1409). Multiparity and increased plasma adiponectin, maternal age, systolic blood pressure and HbA1c were independently associated with uncomplicated pregnancy and birth. These factors achieved an AUROC of 0.72 (0.68-0.76) and the model was well calibrated. Prevalence of gestational diabetes, preeclampsia and other hypertensive disorders, preterm birth, and postpartum haemorrhage decreased whereas spontaneous vaginal delivery increased across the fifths of increasing predicted risk of uncomplicated pregnancy and birth. Sensitivity, specificity, and positive and negative predictive values were 38%, 89%, 63% and 74%, respectively. A simpler model including clinical factors only (no biomarkers) achieved an AUROC of 0.68 (0.65-0.71), with sensitivity, specificity, and positive and negative predictive values of 31%, 86%, 56% and 69%, respectively. Clinical factors and biomarkers can be used to help stratify pregnancy and delivery risk amongst obese pregnant women. Further studies are needed to explore alternative pathways of care for obese women demonstrating different risk profiles for uncomplicated pregnancy and birth.

  4. Framing effects and risk-sensitive decision making.

    PubMed

    Mishra, Sandeep; Gregson, Margaux; Lalumière, Martin L

    2012-02-01

    Prospect theory suggests that people are risk-averse when facing gains, but risk-prone when facing losses, a pattern known as the framing effect. Although framing effects have been widely demonstrated, few studies have investigated framing effects under conditions of need. Risk-sensitivity theory predicts that decision makers should prefer high-risk options in situations of high need, when lower risk options are unlikely to meet those needs. In two experiments, we examined (1) whether framing effects occurred in behavioural tasks involving risky decision making from description and decision making from experience, (2) whether participants' risky decision making conformed to the predictions of risk-sensitivity theory, and (3) whether decision framing interacted with conditions of need to influence decision making under risk. The results suggest that under all circumstances, risky decision making conformed to the predictions of risk-sensitivity theory. Framing effects were at least partially demonstrable under all experimental conditions. Finally, negative frames interacted with situations of high need to produce particularly elevated levels of risky choice. Together, the results suggest that risk-sensitivity theory can augment prospect theory to explain choice under conditions of need. ©2011 The British Psychological Society.

  5. Prospective evaluation of a screening protocol to exclude deep vein thrombosis on the basis of a combination of quantitative D-dimer testing and pretest clinical probability score.

    PubMed

    Yamaki, Takashi; Nozaki, Motohiro; Sakurai, Hiroyuki; Takeuchi, Masaki; Soejima, Kazutaka; Kono, Taro

    2005-11-01

    Clinical signs and symptoms such as swelling, pain, and redness are unreliable markers of deep vein thrombosis (DVT). Because of this venous duplex scanning (VDS) has been heavily used in DVT detection. The purpose of this study was to determine if a combination of D-dimer testing and pretest clinical score could reduce the use of VDS in symptomatic patients with suspected DVT. One hundred seventy-four consecutive patients with suspected DVT were prospectively evaluated using pretest clinical probability (PCP) score and D-dimer testing before VDS. After calculating clinical probability scores developed by Wells and associates, patients were divided into low risk (or=3 points) PCP. One hundred fifty-eight patients were enrolled. The prevalence of DVT in this study was 37%. Thirty-eight patients (24%) were classified as low risk, 64 (41%) as moderate risk, and 56 (35%) as high risk PCP. DVT was identified in only one patient (2.6%) with low risk PCP. In contrast, DVT was found in 22 (34%) with moderate risk, and 35 (63%) with high risk PCP. In the high and moderate risk PCP groups, positive scan patients had a markedly higher value of D-dimer assay than negative scan patients (p=0.0001 and p=0.0057, respectively). In the low risk PCP patients, D-dimer testing provided 100% sensitivity, 46% specificity, 4.8% positive predictive value, and 100% negative predictive value in the diagnosis of DVT. Similarly, in the moderate risk PCP, the D-dimer testing showed 100% sensitivity, 45% specificity, 49% positive predictive value, and 100% negative predictive value. In the high risk group, D-dimer testing achieved 100% sensitivity, 57% specificity, 80% positive predictive value, and 100% negative predictive value in the diagnosis of DVT. These results suggested that 36 of 158 patients who had a non-high PCP (low and moderate PCP) and a normal D-dimer concentration were considered to have no additional investigation, so VDS could have been reduced by 23% (36/158). A combination of D-dimer testing and clinical probability score may be effective in avoiding unnecessary VDS in suspected symptomatic DVT in the low and moderate PCP patients. The need for VDS could be reduced by 23% despite a relatively high prevalence of DVT.

  6. Bladder cancer diagnosis with CT urography: test characteristics and reasons for false-positive and false-negative results.

    PubMed

    Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G

    2018-03-01

    To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.

  7. The Stroke Assessment of Fall Risk (SAFR): predictive validity in inpatient stroke rehabilitation.

    PubMed

    Breisinger, Terry P; Skidmore, Elizabeth R; Niyonkuru, Christian; Terhorst, Lauren; Campbell, Grace B

    2014-12-01

    To evaluate relative accuracy of a newly developed Stroke Assessment of Fall Risk (SAFR) for classifying fallers and non-fallers, compared with a health system fall risk screening tool, the Fall Harm Risk Screen. Prospective quality improvement study conducted at an inpatient stroke rehabilitation unit at a large urban university hospital. Patients admitted for inpatient stroke rehabilitation (N = 419) with imaging or clinical evidence of ischemic or hemorrhagic stroke, between 1 August 2009 and 31 July 2010. Not applicable. Sensitivity, specificity, and area under the curve for Receiver Operating Characteristic Curves of both scales' classifications, based on fall risk score completed upon admission to inpatient stroke rehabilitation. A total of 68 (16%) participants fell at least once. The SAFR was significantly more accurate than the Fall Harm Risk Screen (p < 0.001), with area under the curve of 0.73, positive predictive value of 0.29, and negative predictive value of 0.94. For the Fall Harm Risk Screen, area under the curve was 0.56, positive predictive value was 0.19, and negative predictive value was 0.86. Sensitivity and specificity of the SAFR (0.78 and 0.63, respectively) was higher than the Fall Harm Risk Screen (0.57 and 0.48, respectively). An evidence-derived, population-specific fall risk assessment may more accurately predict fallers than a general fall risk screen for stroke rehabilitation patients. While the SAFR improves upon the accuracy of a general assessment tool, additional refinement may be warranted. © The Author(s) 2014.

  8. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    PubMed

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  9. Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine.

    PubMed

    Zito, Concetta; Dattilo, Giuseppe; Oreto, Giuseppe; Di Bella, Gianluca; Lamari, Annalisa; Iudicello, Raffaella; Trio, Olimpia; Caracciolo, Giuseppe; Coglitore, Sebastiano; Arrigo, Francesco; Carerj, Scipione

    2009-05-01

    The aim of this study was to compare transthoracic echocardiography (TTE) and transcranial Doppler ultrasonography (TCD) with transesophageal echocardiography (TEE) in order to define the best clinical approach to patent foramen ovale (PFO) detection. In total, 72 consecutive patients (33 men) with a mean age of 49 +/- 13 years were prospectively enrolled. The TEE indication was cryptogenic stroke (36 patients) or migraine (36 patients, 22 with aura). All patients underwent standard TTE, TCD, and TEE examination. For any study, a contrast test was carried on using an agitated saline solution mixed with urea-linked gelatine (Haemaccel), injected as a rapid bolus via a right antecubital vein. A prolonged Valsalva maneuver was performed to improve test sensitivity. TEE identified a PFO in 65% of the whole population: 56.5% in the migraine cohort and 43.5% in the cryptogenic stroke cohort. TTE was able to detect a PFO in 55% of patients positive at TEE (54% negative predictive value, 100% positive predictive value, 55% sensitivity, and 100% specificity). TCD was able to identify a PFO in 97% of patients positive at TEE (89% negative predictive value, 98% positive predictive value, 94% sensitivity, and 96% specificity). In patients with cryptogenic stroke and migraine, there is a fair concordance (k = 0.89) between TCD and TEE in PFO recognition. Accordingly, TCD should be recommended as a simple, noninvasive, and reliable technique, whereas TEE indication should be restricted to selected patients. TTE is a very specific technique, whose major advantage is the ability to detect a large right-to-left shunt, particularly if associated with an atrial septal aneurysm.

  10. Multistix 10 SG Leukocyte Esterage Dipstick Testing in Rapid Bedside Diagnosis of Spontaneous Bacterial Peritonitis: A Prospective Study.

    PubMed

    Jha, Ashish K; Kumawat, Dal C; Bolya, Yasvant K; Goenka, Mahesh K

    2012-09-01

    Spontaneous bacterial peritonitis (SBP) requires rapid diagnosis and the initiation of antibiotics. Diagnosis of SBP is usually based on cytobacteriological examination of ascitic fluid. These tests require good laboratory facilities and reporting time of few hours to 1-2 day. However, the 24 h laboratory facilities not widely available in country like India. We evaluated the diagnostic utility of reagent strip (Multistix 10 SG(®)) for rapid diagnosis of SBP. The study was prospectively carried out on patients of cirrhosis with ascites. Bedside leukocyte esterase reagent strip testing was performed on ascitic fluid. Cell count as determined by colorimetric scale of reagent strip was compared with counting chamber method. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Out of 100 patients with cirrhotic ascites, [72 males: 28 female; mean age 44.34 (SD 13.03) years] 18 patients were diagnosed to have SBP by counting chamber method as compared to 14 patients detected to have SBP by reagent strip test ≥++ positive. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of reagent strip ≥++ positive were 77.77%, 95.12%, 77.77%, 95.12% and 92% respectively compared to counting chamber method. Reagent strip to diagnose SBP is very specific but less sensitive as compared to counting chamber method. This can be performed rapidly, easily and efficiently even in remote area of developing countries. This bedside test could be a useful tool for the diagnosis of SBP in country like India.

  11. Validation of the Hospital Anxiety and Depression Scale in patients with epilepsy.

    PubMed

    Wiglusz, Mariusz S; Landowski, Jerzy; Michalak, Lidia; Cubała, Wiesław J

    2016-05-01

    Despite the fact that depressive disorders are the most common comorbidities among patients with epilepsy (PWEs), they often go unrecognized and untreated. The availability of validated screening instruments to detect depression in PWEs is limited. The aim of the present study was to validate the Hospital Anxiety and Depression Scale (HADS) in adult PWEs. A consecutive group of 118 outpatient PWEs was invited to participate in the study. Ninety-six patients met inclusion criteria, completed HADS, and were examined by a trained psychiatrist using Structured Clinical Interview (SCID-I) for DSM-IV-TR. Receiver operating characteristic (ROC) curves were used to determine the optimal threshold scores for the HADS depression subscale (HADS-D). Receiver operating characteristic analyses showed areas under the curve at approximately 84%. For diagnoses of MDD, the HADS-D demonstrated the best psychometric properties for a cutoff score ≥7 with sensitivity of 90.5%, specificity of 70.7%, positive predictive value of 46.3%, and negative predictive value of 96.4%. In the case of the group with 'any depressive disorder', the HADS-D optimum cutoff score was ≥6 with sensitivity of 82.5%, specificity of 73.2%, positive predictive value of 68.8%, and negative predictive value of 85.4%. The HADS-D proved to be a valid and reliable psychometric instrument in terms of screening for depressive disorders in PWEs. In the epilepsy setting, HADS-D maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing MDD with an optimum cutoff score ≥7. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The utility of the Edmonton Symptom Assessment System in screening for anxiety and depression.

    PubMed

    Bagha, S M; Macedo, A; Jacks, L M; Lo, C; Zimmermann, C; Rodin, G; Li, M

    2013-01-01

    The Edmonton Symptom Assessment System (ESAS) is a common screening tool in cancer, although its validity for distress screening is unproven. Here, screening performance of the ESAS anxiety (ESAS-A) and depression (ESAS-D) items were validated against the anxiety [Generalised Anxiety Disorder-7 (GAD-7)] and depression [Patient Health Questionnaire-9 (PHQ-9)] subscales of the PHQ. A total of 1215 cancer patients completed the Distress Assessment and Response Tool (DART), a computerised distress screening instrument. Spearman's rank correlation coefficients and receiver operating characteristic curve analyses were used to evaluate the ability of ESAS-A and ESAS-D to identify moderate distress (GAD-7/PHQ-9 ≥ 10). Spearman's rank correlation coefficients comparing ESAS-A and ESAS-D with GAD-7 and PHQ-9 were 0.74 and 0.72 respectively. Areas under the receiver operating characteristic curves were 0.89 and 0.88 for anxiety and depression respectively. A cut-off of ≥3 on ESAS-A demonstrated a sensitivity of 0.91, specificity of 0.68, positive predictive value of 0.34 and negative predictive value of 0.97. A cut-off of ≥2 on the ESAS-D demonstrated a sensitivity of 0.86, specificity of 0.72, positive predictive value of 0.46 and negative predictive value of 0.95. High sensitivities of ESAS-A and ESAS-D at certain cut-offs suggest they have use in ruling-out distress. However, their low specificities indicate secondary screening is needed to rule-in anxiety or depression for case-finding. © 2012 Blackwell Publishing Ltd.

  13. Outcomes analysis of new entrant screening for active tuberculosis in Heathrow and Gatwick airports, United Kingdom 2009/2010.

    PubMed

    Severi, Ettore; Maguire, Helen; Ihekweazu, Chikwe; Bickler, Graham; Abubakar, Ibrahim

    2016-04-22

    In 2012, the United Kingdom (UK) Government announced that the new entrant screening for active tuberculosis (TB) in Heathrow and Gatwick airports would end. Our study objective was to estimate screening yield and diagnostic accuracy, and identify those at risk of active TB after entry. We designed a retrospective cohort study and linked new entrants screened from June 2009 to September 2010 through probabilistic matching with UK Enhanced TB Surveillance (ETS) data (June 2009 to December 2010). Yield was the proportion of cases reported to ETS within three months of airport screening in the screened population. To estimate screening diagnostic accuracy we assessed sensitivity, specificity, positive and negative predictive values. Through Poisson regression we identified groups at increased risk of TB diagnosis after entry. We identified 200,199 screened entrants, of these 59 had suspected TB at screening and were reported within 3 months to ETS (yield = 0.03 %). Sensitivity was 26 %; specificity was 99.7 %; positive predictive value was 13.2 %; negative predictive value was 99.9 %. Overall, 350 entrants were reported in ETS. Persons from countries with annual TB incidence higher than 150 cases per 100,000 population and refugees and asylum seekers were at increased risk of TB diagnosis after entry (population attributable risk 77 and 3 % respectively). Airport screening has very low screening yields, sensitivity and positive predictive value. New entrants coming from countries with annual TB incidence higher than 150 per 100,000 population, refugees and asylum seekers should be prioritised at pre- or post-entry screening.

  14. FLOCK cluster analysis of mast cell event clustering by high-sensitivity flow cytometry predicts systemic mastocytosis.

    PubMed

    Dorfman, David M; LaPlante, Charlotte D; Pozdnyakova, Olga; Li, Betty

    2015-11-01

    In our high-sensitivity flow cytometric approach for systemic mastocytosis (SM), we identified mast cell event clustering as a new diagnostic criterion for the disease. To objectively characterize mast cell gated event distributions, we performed cluster analysis using FLOCK, a computational approach to identify cell subsets in multidimensional flow cytometry data in an unbiased, automated fashion. FLOCK identified discrete mast cell populations in most cases of SM (56/75 [75%]) but only a minority of non-SM cases (17/124 [14%]). FLOCK-identified mast cell populations accounted for 2.46% of total cells on average in SM cases and 0.09% of total cells on average in non-SM cases (P < .0001) and were predictive of SM, with a sensitivity of 75%, a specificity of 86%, a positive predictive value of 76%, and a negative predictive value of 85%. FLOCK analysis provides useful diagnostic information for evaluating patients with suspected SM, and may be useful for the analysis of other hematopoietic neoplasms. Copyright© by the American Society for Clinical Pathology.

  15. Severe community-acquired pneumonia. Assessment of severity criteria.

    PubMed

    Ewig, S; Ruiz, M; Mensa, J; Marcos, M A; Martinez, J A; Arancibia, F; Niederman, M S; Torres, A

    1998-10-01

    The purpose of the study was to validate the criteria used in the guidelines of the American Thoracic Society (ATS) for severe community-acquired pneumonia (CAP). Severe pneumonia was defined as admission to the intensive care unit (ICU). Overall 331 nonsevere (84%) and 64 severe cases (16%) of CAP were prospectively studied. Mortality was 19 of 395 (5%) and 19 of 64 (30%), respectively. Single severity criteria as well as the ATS definition of severe pneumonia were assessed calculating the operative indices. A modified prediction rule including minor (baseline) and major (baseline or evolutionary) criteria was derived. Single minor criteria at admission had a low sensitivity and positive predictive value. Defining severe pneumonia according to the ATS guidelines had a high sensitivity (98%). However, specificity and positive predictive value were low (32% and 24%, respectively). A modified prediction rule (presence of two or three minor criteria [systolic blood pressure < 90 mm Hg, multilobar involvement, PaO2/FIO2 < 250] or one of two major criteria [requirement of mechanical ventilation, presence of septic shock]) had a sensitivity of 78%, a specificity of 94%, a positive predictive value of 75%, and a negative predictive value of 95%. The ATS definition of severe pneumonia was highly sensitive but insufficiently specific and had a low positive predictive value. Our suggested modified rule had a more balanced performance and, if validated in an independent population, may represent a more accurate definition of severe CAP.

  16. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    PubMed

    Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan

    2016-01-01

    Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P < 0.001. Parallel testing of histological AFB staining and PCR showed the sensitivity, specificity, PPV, NPV, and accuracy to be 94.0% (125/133), 95.8% (46/48), 98.4% (125/127), 85.2% (46/54), and 94.5% (171/181), respectively. Among patients with positive AFB and negative PCR results in lung tissue specimens, two were diagnosed with NTM infections (Mycobacterium avium-intracellulare complex and Mycobacterium kansasii). Nucleic acid amplification testing combined with acid-fast staining in lung biopsy tissues can lead to early and accurate diagnosis in patients with smear-negative pulmonary tuberculosis. For patients with positive histological AFB and negative tuberculous PCR results in lung tissue, NTM infection should be suspected and could be identified by specific probe assays or 16S rRNA sequencing.

  17. Diagnostic performance of a biomarker panel as a negative predictor for acute appendicitis in adult ED patients with abdominal pain.

    PubMed

    Huckins, David S; Copeland, Karen; Self, Wesley; Vance, Cheryl; Hendry, Phyllis; Borg, Keith; Gogain, Joseph

    2017-03-01

    Evaluate the diagnostic accuracy of the APPY1TM biomarker panel, previously described for use in pediatric patients, for identifying adult ED patients with abdominal pain who are at low risk of acute appendicitis. This study prospectively enrolled subjects >18years of age presenting to seven U.S. emergency departments with <72hours of abdominal pain suggesting possible acute appendicitis. The APPY1 panel was performed on blood samples drawn from each patient at the time of initial evaluation and results were correlated with the final diagnosis either positive or negative for acute appendicitis. 431 patients were enrolled with 422 completing all aspects of the study. The APPY1 biomarker panel exhibited a sensitivity of 97.5% (95% CI, 91.3-99.3%), a negative predictive value of 98.4% (95% CI, 94.4-99.6%), a negative likelihood ratio of 0.07 (95% CI, 0.02-0.27), with a specificity of 36.5% (95% CI, 31.6-41.8%) for acute appendicitis. The panel correctly identified 125 of 342 (36.6%) patients who did not have appendicitis with 2 (2.5%) false negatives. The CT utilization rate in this population was 72.7% (307/422). Of 307 CT scans, 232 were done for patients who did not have appendicitis and 79 (34%) of these patients were correctly identified as negative with "low risk" biomarker panel results, representing 26% (79/307) of all CT scans performed. This biomarker panel exhibited high sensitivity and negative predictive value for acute appendicitis in this prospective adult cohort, thereby potentially reducing the dependence on CT for the evaluation of possible acute appendicitis. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Detection of human papillomavirus DNA in patients referred to a family practice colposcopy clinic.

    PubMed

    Holman, J R

    1996-01-01

    Human papillomavirus (HPV) is strongly implicated in the pathogenesis of cervical neoplasia. The ability of a commercially available kit (Virapap/Viratype) to detect evidence of HPV is compared with cervical cytology, colposcopy, and directed biopsies. During a period of 16 months, cervical samples from 241 consecutive new patients referred for a colposcopy examination were obtained for HPV-DNA hybridization typing according to the kit instructions. Samples were sent to a reference laboratory for testing. The results were compared with results of the colposcopy examination, cervical cytology, and directed cervical biopsy samples processed and evaluated by our hospital laboratory. HPV DNA was detected in 27 of 107 patients who had abnormal colposcopy findings for a sensitivity of 25 +/- 7.5 percent at the 90 percent confidence interval. One of 134 patients with normal findings was positive for a specificity of 99 +/- 5 percent at the 95 percent confidence interval. Based on a 75 percent probability of HPV in the population, the positive predictive value was 99 percent and the negative predictive value 30 percent. With the low negative predictive value and sensitivity, HPV-DNA testing by this commercial kit is not an adequate tool for screening HPV in this population.

  19. Comparison of Selamectin and Imidacloprid plus Permethrin in Eliminating Leporacarus gibbus Infestation in Laboratory Rabbits (Oryctolagus cuniculus)

    PubMed Central

    Birke, Leslie L; Molina, Patricia E; Baker, David G; Leonard, Stuart T; Marrero, Luis J; Johnson, Merlin; Simkin, Jennifer

    2009-01-01

    A shipment of New Zealand white rabbits was infested with Leporacarus gibbus, a rabbit fur mite. This study compared the effectiveness of selamectin with that of imidocloprid plus permethrin in eliminating the mite infestation. Rabbits were divided into 2 groups, and either selamectin or imidocloprid plus permethrin was applied topically. Visual and microscopic examinations were performed on days 0, 1, 2, 3, 4, 5, 6, 13, and 27 for 5 sites (the left and right gluteal areas, neck, ventral tail, and abdomen). Mean percentage effectiveness for each treatment was calculated for each time point. Positive and negative predictive value, sensitivity, and specificity of visual examination were determined relative to microscopic assessment. In addition, location prevalence for the mites was determined. Both treatments were 100% effective by day 13, but selamectin was 100% effective by day 3. The positive predictive value of visual examination was 96%, its negative predictive value was 86%, sensitivity was 75%, and specificity was 98%. Parasite burden was most prevalent on the right and left gluteal areas. We conclude that although both imidocloprid plus permethrin and selamectin were effective against L. gibbus, treatment with selamectin more rapidly eliminated the infestation. PMID:19930824

  20. Diagnostic value of highly-sensitive chimerism analysis after allogeneic stem cell transplantation.

    PubMed

    Sellmann, Lea; Rabe, Kim; Bünting, Ivonne; Dammann, Elke; Göhring, Gudrun; Ganser, Arnold; Stadler, Michael; Weissinger, Eva M; Hambach, Lothar

    2018-05-02

    Conventional analysis of host chimerism (HC) frequently fails to detect relapse before its clinical manifestation in patients with hematological malignancies after allogeneic stem cell transplantation (allo-SCT). Quantitative PCR (qPCR)-based highly-sensitive chimerism analysis extends the detection limit of conventional (short tandem repeats-based) chimerism analysis from 1 to 0.01% host cells in whole blood. To date, the diagnostic value of highly-sensitive chimerism analysis is hardly defined. Here, we applied qPCR-based chimerism analysis to 901 blood samples of 71 out-patients with hematological malignancies after allo-SCT. Receiver operating characteristics (ROC) curves were calculated for absolute HC values and for the increments of HC before relapse. Using the best cut-offs, relapse was detected with sensitivities of 74 or 85% and specificities of 69 or 75%, respectively. Positive predictive values (PPVs) were only 12 or 18%, but the respective negative predictive values were 98 or 99%. Relapse was detected median 38 or 45 days prior to clinical diagnosis, respectively. Considering also durations of steadily increasing HC of more than 28 days improved PPVs to more than 28 or 59%, respectively. Overall, highly-sensitive chimerism analysis excludes relapses with high certainty and predicts relapses with high sensitivity and specificity more than a month prior to clinical diagnosis.

  1. Effectiveness of the critical congenital heart disease screening program for early diagnosis of cardiac abnormalities in newborn infants.

    PubMed

    Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B

    2017-10-01

    To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants.  Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at  Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.

  2. [Diagnostic accuracy of fine needle aspiration cytology in parotid tumours].

    PubMed

    Zerpa Zerpa, Vanessa; Cuesta Gonzáles, Maria Teresa; Agostini Porras, Gabriela; Marcano Acuña, Martin; Estellés Ferriol, Enrique; Dalmau Galofre, José

    2014-01-01

    Fine needle aspiration cytology (FNAC) is a globally accepted technique in the preoperative evaluations of head and neck tumours; however, the effectiveness in the interpretation of salivary glands neoplastic lesions is still controversial. The objective of this study consisted of assessing the efficacy of FNAC in preoperative diagnosis of parotid tumours. This retrospective study was conducted using 93 patient samples with parotid gland tumoral pathology, treated at the Otorhinolaryngology Department in our institution during the 2007-2011 period. Preoperative FNAC was employed and the patients subsequently submitted to surgical excision with histopathological diagnosis of the specimen. Cytology results were classified as negative for malignancy, positive for malignancy or insufficient sample, and later compared with the definitive histological diagnosis. The mean age of the studied sample was 52.9 years (range: 11 to 88 years); 55.9% were men. The FNAC showed significant sensitivity of 57.1%, with a specificity of 95.1%, for detecting malignancy in parotid gland tumours. The positive and negative predictive values for malignancy were 50 and 96.3%, respectively. FNAC is considered a simple test but of limited use for diagnostic guidance in tumour pathology of the parotid gland in our environment, mainly because of its low sensitivity. However, the high specificity and high negative predictive value of FNAC makes it a more accurate test in benign or negative result cases. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  3. Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.

    PubMed

    Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein

    2016-06-01

    Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.

  4. Lessons learned from the use of HRP-2 based rapid diagnostic test in community-wide screening and treatment of asymptomatic carriers of Plasmodium falciparum in Burkina Faso.

    PubMed

    Tiono, Alfred B; Ouédraogo, Alphonse; Diarra, Amidou; Coulibaly, Sam; Soulama, Issiaka; Konaté, Amadou T; Barry, Aïssata; Mukhopadhyay, Amitava; Sirima, Sodiomon B; Hamed, Kamal

    2014-01-27

    Rapid diagnostic tests (RDTs) are immune chromatographic tests targeting antigens of one or more Plasmodium species and offer the potential to extend accurate malaria diagnosis in endemic areas. In this study, the performance of Plasmodium falciparum-specific histidine-rich protein-2 (PfHRP-2) RDT in the detection of asymptomatic carriers from a hyperendemic region of Burkina Faso was compared with microscopy to gain further insight on its relevance in community-based interventions. The performance of HRP-2 test was evaluated in terms of sensitivity, specificity, positive and negative predictive values, discordant values, likelihood ratios, accuracy, and precision using microscopy as the 'gold standard'. This analysis was carried out in a controlled, parallel, cluster-randomized (18 clusters; 1:1) study in children and adults. The effect of systematic treatment of P. falciparum asymptomatic carriers during three consecutive monthly community screening campaigns on the incidence of symptomatic malaria episodes over a 12-month period was compared with no treatment of asymptomatic carriers. Sensitivity of HRP-2 test in asymptomatic carriers was higher in campaign 1 (92.4%) when compared to campaign 2 (84.0%) and campaign 3 (77.8%). The sensitivity of HRP-2 test increased as parasite density increased across all the age groups. Highest sensitivity (≥97.0%) was recorded at parasite densities of 1,000-4,999/μl, except for children aged 10 to 14 years. The specificity of HRP-2 test was comparable across age groups and highest in campaign 3 (95.9%). The negative predictive values were high across the three campaigns (≥92.7%) while the positive predictive values ranged from 23.2 to 73.8%. False-positive and false-negative rates were high in campaign 1 and campaign 3, respectively. The performance of HRP-2 test in detecting asymptomatic carriers of P. falciparum varied by age and parasite density. Although the use of HRP-2 test is beneficial for the diagnosis of acute malaria, its low sensitivity in screening asymptomatic carriers may limit its utility in pre-elimination interventional settings. The use of a practical and more sensitive test such as loop-mediated isothermal amplification in combination with a cost effective HRP-2 test may be worth exploring in such settings.

  5. Performance of the OraQuick HCV rapid antibody test for screening exposed patients in a hepatitis C outbreak investigation.

    PubMed

    Gao, Fengxiang; Talbot, Elizabeth A; Loring, Carol H; Power, Jill J; Dionne-Odom, Jodie; Alroy-Preis, Sharon; Jackson, Patricia; Bean, Christine L

    2014-07-01

    During a nosocomial hepatitis C outbreak, emergency public clinics employed the OraQuick HCV rapid antibody test on site, and all results were verified by a standard enzyme immunoassay (EIA). Of 1,157 persons, 1,149 (99.3%) exhibited concordant results between the two tests (16 positive, 1,133 negative). The sensitivity, specificity, positive predictive value, and negative predictive value were 94.1%, 99.5%, 72.7%, and 99.9%, respectively. OraQuick performed well as a screening test during an outbreak investigation and could be integrated into future hepatitis C virus (HCV) outbreak testing algorithms. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  6. Flow Test to Predict Early Hypotony and Hypertensive Phase After Ahmed Glaucoma Valve (AGV) Surgical Implantation.

    PubMed

    Cheng, Jason; Beltran-Agullo, Laura; Buys, Yvonne M; Moss, Edward B; Gonzalez, Johanna; Trope, Graham E

    2016-06-01

    To assess the validity of a preimplantation flow test to predict early hypotony [intraocular pressure (IOP)≤5 mm Hg on 2 consecutive visits and hypertensive phase (HP) (IOP>21 mm Hg) after Ahmed Glaucoma Valve (AGV) implantation. Prospective interventional study on patients receiving an AGV. A preimplantation flow test using a gravity-driven reservoir and an open manometer was performed on all AGVs. Opening pressure (OP) and closing pressure (CP) were defined as the pressure at which fluid was seen to flow or stop flowing through the AGV, respectively. OP and CP were measured twice per AGV. Patients were followed for 12 weeks. In total, 20 eyes from 19 patients were enrolled. At 12 weeks the mean IOP decreased from 29.2±9.1 to 16.8±5.2 mm Hg (P<0.01). The mean AGV OP was 17.5±5.4 mm Hg and the mean CP was 6.7±2.3 mm Hg. Early (within 2 wk postoperative) HP occurred in 37% and hypotony in 16% of cases. An 18 mm Hg cutoff for the OP gave a sensitivity of 0.71, specificity of 0.83, positive predictive value of 0.71, and negative predictive value of 0.83 for predicting an early HP. A 7 mm Hg cutoff for the CP yielded a sensitivity of 1.0, specificity of 0.38, positive predictive value of 0.23, and negative predictive value of 1.0 for predicting hypotony. Preoperative OP and CP may predict early hypotony or HP and may be used as a guide as to which AGV valves to discard before implantation surgery.

  7. Validity of parent's self-reported responses to home safety questions.

    PubMed

    Osborne, Jodie M; Shibl, Rania; Cameron, Cate M; Kendrick, Denise; Lyons, Ronan A; Spinks, Anneliese B; Sipe, Neil; McClure, Roderick J

    2016-09-01

    The aim of the study was to describe the validity of parent's self-reported responses to questions on home safety practices for children of 2-4 years. A cross-sectional validation study compared parent's self-administered responses to items in the Home Injury Prevention Survey with home observations undertaken by trained researchers. The relationship between the questionnaire and observation results was assessed using percentage agreement, sensitivity, specificity, positive predictive value, negative predictive value and intraclass correlation coefficients. Percentage agreements ranged from 44% to 100% with 40 of the total 45 items scoring higher than 70%. Sensitivities ranged from 0% to 100%, with 27 items scoring at least 70%. Specificities also ranged from 0% to 100%, with 33 items scoring at least 70%. As such, the study identified a series of self-administered home safety questions that have sensitivities, specificities and predictive values sufficiently high to allow the information to be useful in research and injury prevention practice.

  8. Assessing the stability of human locomotion: a review of current measures

    PubMed Central

    Bruijn, S. M.; Meijer, O. G.; Beek, P. J.; van Dieën, J. H.

    2013-01-01

    Falling poses a major threat to the steadily growing population of the elderly in modern-day society. A major challenge in the prevention of falls is the identification of individuals who are at risk of falling owing to an unstable gait. At present, several methods are available for estimating gait stability, each with its own advantages and disadvantages. In this paper, we review the currently available measures: the maximum Lyapunov exponent (λS and λL), the maximum Floquet multiplier, variability measures, long-range correlations, extrapolated centre of mass, stabilizing and destabilizing forces, foot placement estimator, gait sensitivity norm and maximum allowable perturbation. We explain what these measures represent and how they are calculated, and we assess their validity, divided up into construct validity, predictive validity in simple models, convergent validity in experimental studies, and predictive validity in observational studies. We conclude that (i) the validity of variability measures and λS is best supported across all levels, (ii) the maximum Floquet multiplier and λL have good construct validity, but negative predictive validity in models, negative convergent validity and (for λL) negative predictive validity in observational studies, (iii) long-range correlations lack construct validity and predictive validity in models and have negative convergent validity, and (iv) measures derived from perturbation experiments have good construct validity, but data are lacking on convergent validity in experimental studies and predictive validity in observational studies. In closing, directions for future research on dynamic gait stability are discussed. PMID:23516062

  9. Utility of peripheral blood immunophenotyping by flow cytometry in the diagnosis of pediatric acute leukemia.

    PubMed

    Metrock, Laura K; Summers, Ryan J; Park, Sunita; Gillespie, Scott; Castellino, Sharon; Lew, Glen; Keller, Frank G

    2017-10-01

    Childhood acute leukemia is traditionally diagnosed from a bone marrow aspirate (BMA). New-onset acute leukemia patients do not always have visible circulating blasts in the peripheral blood (PB) at diagnosis. While the role of bone marrow flow cytometry for the diagnosis of acute leukemia is well established, the utility of PB flow cytometry (PBFC) is unknown. We performed a single-institution retrospective analysis to compare PBFC versus BMA in establishing or excluding a diagnosis of childhood acute leukemia. We retrospectively identified 485 PBFC samples with concurrent BMA from 2008 to 2013. Results of four-color flow cytometry for immunophenotypic characterization of leukemic versus nonclonal disease were characterized. Sensitivity and specificity were calculated among patients without a known diagnosis or prior therapy. Among 485 samples eligible for analysis, 120 had negative PBFC and BMA, 359 had positive PBFC and BMA, 3 had negative PBFC and positive BMA, and 3 had positive PBFC and negative BMA. There were small but significant differences in sensitivity (100 vs. 93.8%; P = 0.002) and positive predictive value (100 vs. 93.8%; P = 0.002) favoring BMA over PBFC among those demonstrating absence of circulating morphologic blasts. PBFC has high sensitivity and specificity for the diagnosis of childhood acute leukemia. The predictive value of PBFC remains high for patients without visible circulating blasts and may enhance the diagnostic process for determining the indications for marrow testing. © 2017 Wiley Periodicals, Inc.

  10. The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.

    PubMed

    Teppa, Roberto J; Roberts, James M

    2005-01-01

    Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.

  11. Issues in the Development of the AIDMAN VISION SCREENER

    DTIC Science & Technology

    1990-12-01

    relationship between the P-T ratio and disease prevalence . As indicated in the bottom portion of Figure 2, the predictive value of any screening test is...absence of disease/injury The Importance of Disease/Injury Prevalence Disease Prevalence - (TP + FN) / TOTAL The specificity and sensitivity The positive...and negative (and their corresponding inverses) predictive values of a given test of a given test are not affected by disease prevalence ! are affected

  12. Multi-risk infants: predicting attachment security from sociodemographic, psychosocial, and health risk among African-American preterm infants.

    PubMed

    Candelaria, Margo; Teti, Douglas M; Black, Maureen M

    2011-08-01

    Ecological and transactional theories link child outcomes to accumulated risk. This study hypothesized that cumulative risk was negatively related to attachment, and that maternal sensitivity mediated linkages between risk and attachment. One hundred and twelve high-risk African-American premature infant-mother dyads participated. Psychosocial (maternal depression, stress and self-efficacy) and sociodemographic risk (poverty, maternal education, marital status) were maternal self-report (0-4 months). Infant health risk was obtained from hospital charts. Infant-mother attachment (12 months) and maternal sensitivity (4 months) were assessed with Q-sort measures. Psychosocial and sociodemographic risk, but not infant health risk, negatively related to attachment. Both were mediated by maternal sensitivity. The impact of risk domains on attachment security was mediated by maternal sensitivity. Results emphasize the need for early intervention programs targeting premature infants to identify and address environmental and personal factors that place parenting at risk. © 2011 The Authors. Journal of Child Psychology and Psychiatry © 2011 Association for Child and Adolescent Mental Health.

  13. Nervous System Sensitization as a Predictor of Outcome in the Treatment of Peripheral Musculoskeletal Conditions: A Systematic Review.

    PubMed

    O'Leary, Helen; Smart, Keith M; Moloney, Niamh A; Doody, Catherine M

    2017-02-01

    Research suggests that peripheral and central nervous system sensitization can contribute to the overall pain experience in peripheral musculoskeletal (MSK) conditions. It is unclear, however, whether sensitization of the nervous system results in poorer outcomes following the treatment. This systematic review investigated whether nervous system sensitization in peripheral MSK conditions predicts poorer clinical outcomes in response to a surgical or conservative intervention. Four electronic databases were searched to identify the relevant studies. Eligible studies had a prospective design, with a follow-up assessing the outcome in terms of pain or disability. Studies that used baseline indices of nervous system sensitization were included, such as quantitative sensory testing (QST) or questionnaires that measured centrally mediated symptoms. Thirteen studies met the inclusion criteria, of which six were at a high risk of bias. The peripheral MSK conditions investigated were knee and hip osteoarthritis, shoulder pain, and elbow tendinopathy. QST parameters indicative of sensitization (lower electrical pain thresholds, cold hyperalgesia, enhanced temporal summation, lower punctate sharpness thresholds) were associated with negative outcome (more pain or disability) in 5 small exploratory studies. Larger studies that accounted for multiple confounders in design and analysis did not support a predictive relationship between QST parameters and outcome. Two studies used self-report measures to capture comorbid centrally mediated symptoms, and found higher questionnaire scores were independently predictive of more persistent pain following a total joint arthroplasty. This systematic review found insufficient evidence to support an independent predictive relationship between QST measures of nervous system sensitization and treatment outcome. Self-report measures demonstrated better predictive ability. Further high-quality prognostic research is warranted. © 2016 World Institute of Pain.

  14. Predictive value of high-sensitivity troponin-I for future adverse cardiovascular outcome in stable patients with type 2 diabetes mellitus

    PubMed Central

    2014-01-01

    Introduction High-sensitivity cardiac troponin I(hs-TnI) and T levels(hs-TnT) are sensitive biomarkers of cardiomyocyte turnover or necrosis. Prior studies of the predictive role of hs-TnT in type 2 diabetes mellitus(T2DM) patients have yielded conflicting results. This study aimed to determine whether hs-TnI, which is detectable in a higher proportion of normal subjects than hsTnT, is associated with a major adverse cardiovascular event(MACE) in T2DM patients. Methods and results We compared hs-TnI level in stored serum samples from 276 consecutive patients (mean age 65 ± 10 years; 57% male) with T2DM with that of 115 age-and sex-matched controls. All T2DM patients were prospectively followed up for at least 4 years for incidence of MACE including heart failure(HF), myocardial infarction(MI) and cardiovascular mortality. At baseline, 274(99%) patients with T2DM had detectable hs-TnI, and 57(21%) had elevated hs-TnI (male: 8.5 ng/L, female: 7.6 ng/L, above the 99th percentile in healthy controls). A total of 43 MACE occurred: HF(n = 18), MI(n = 11) and cardiovascular mortality(n = 14). Kaplan-Meier analysis showed that an elevated hs-TnI was associated with MACE, HF, MI and cardiovascular mortality. Although multivariate analysis revealed that an elevated hs-TnI independently predicted MACE, it had limited sensitivity(62.7%) and positive predictive value(38.5%). Contrary to this, a normal hs-TnI level had an excellent negative predictive value(92.2%) for future MACE in patients with T2DM. Conclusion The present study demonstrates that elevated hs-TnI in patients with T2DM is associated with increased MACE, HF, MI and cardiovascular mortality. Importantly, a normal hs-TnI level has an excellent negative predictive value for future adverse cardiovascular events during long-term follow-up. PMID:24661773

  15. Clinical significance of FDG-PET/CT at the postoperative surveillance in the breast cancer patients.

    PubMed

    Jung, Na Young; Yoo, Ie Ryung; Kang, Bong Joo; Kim, Sung Hun; Chae, Byung Joo; Seo, Ye Young

    2016-01-01

    We evaluated the clinical role of [(18)F]-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) compared with conventional imaging (CI) to detect locoregional recurrence or distant metastasis during postoperative surveillance of patients with breast cancer. We included 1,819 examinations of 1,161 patients, who underwent FDG-PET/CT and CI, including mammography, breast ultrasound, whole-body bone scintigraphy, and chest radiography for postoperative surveillance. All patients had a history of surgery with or without adjuvant treatment due to more than stage II breast cancer between November 2003 and November 2009. We evaluated the diagnostic performance of CI, FDG-PET/CT, and combined CI and FDG-PET/CT for detecting locoregional recurrence, distant metastasis, and incidental cancer. We also analyzed false-positive and false-negative results in both FDG-PET/CT and CI. Sensitivity, specificity, positive predictive value, and negative predictive value of CI were 75.4, 98.7, 93.4, and 94.3 %. Those of FDG-PET/CT were 97.5, 98.8, 95.4, and 99.4 %. Those of the combined results were 98.6, 98.2, 96.7, and 99.7 %. Sensitivity of FDG-PET/CT was significantly higher than that of CI (P < 0.05). Sensitivity of combined CI and FDG-PET/CT results improved, but they were not significantly different from those of FDG-PET/CT alone (P = 0.43). Seventeen false-positive and nine false-negative cases were detected with FDG-PET/CT, and 19 false-positive and 88 false-negative cases were detected with CI. FDG-PET/CT is considered as an acceptable diagnostic imaging modality for postoperative surveillance of patients with breast cancer.

  16. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  17. The search for an elusive cutoff remains: Problems of binary classification of heavy drinking as an endpoint for alcohol clinical trials.

    PubMed

    Pearson, Matthew R; Bravo, Adrian J; Kirouac, Megan; Witkiewitz, Katie

    2017-02-01

    To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n=1726) and COMBINE (n=1383). In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Use of polymerase chain reaction for the detection of Chlamydia trachomatis in ocular and nasopharyngeal specimens from infants with conjunctivitis.

    PubMed

    Hammerschlag, M R; Roblin, P M; Gelling, M; Tsumura, N; Jule, J E; Kutlin, A

    1997-03-01

    Chlamydia trachomatis is the most common identifiable infectious cause of neonatal conjunctivitis. Nonculture tests including enzyme immunoassays and direct fluorescent antibody tests have been shown to perform well for the diagnosis of chlamydial conjunctivitis with sensitivities and specificities > or = 90%. However, the performance with respiratory specimens has been less than satisfactory. We compared a new, commercially available polymerase chain reaction (PCR) assay, Roche AMPLICOR (Roche Diagnostic Systems, Branchburg, NJ) with culture for the detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis. We also evaluated AMPLICOR for the detection of C. trachomatis in the urine of mothers of positive infants. Ocular and nasopharyngeal specimens from 75 infants with conjunctivitis were obtained for culture and PCR. AMPLICOR was equivalent to culture for eye specimens and more sensitive than culture for nasopharyngeal specimens. The sensitivity, specificity and positive and negative predictive values of PCR compared with culture for conjunctival specimens were 92.3, 100, 100 and 98.4%, respectively. The sensitivity, specificity and positive and negative predictive values for nasopharyngeal specimens were 100, 97.2, 60 and 100%, respectively. We also detected C. trachomatis by PCR in the urine of 12 mothers of culture positive infants. PCR performed comparably to culture for detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis.

  19. The Search for an Elusive Cutoff Remains: Problems of Binary Classification of Heavy Drinking as an Endpoint for Alcohol Clinical Trials

    PubMed Central

    Pearson, Matthew R.; Bravo, Adrian J.; Kirouac, Megan; Witkiewitz, Katie

    2017-01-01

    Background To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. Methods We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n = 1,726) and COMBINE (n = 1,383). Results In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. Conclusions These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. PMID:28038361

  20. Sensitivity to disgust, stigma, and adjustment to life with a colostomy

    PubMed Central

    Smith, Dylan M.; Loewenstein, George; Rozin, Paul; Sherriff, Ryan L.; Ubel, Peter A.

    2007-01-01

    We examined whether trait disgust sensitivity predicts well-being in colostomy patients, and whether disgust predicts stigmatizing attitudes about colostomy in non-patients. 195 patients with a colostomy returned a mailed survey including measures of disgust sensitivity, life satisfaction, mood, and feelings of being stigmatized. We also conducted an internet-survey of a non-patient sample (n = 523). In the patient sample, we observed negative correlations between a bowel-specific measure of disgust sensitivity and life satisfaction (r = −.34, p<.01), and colostomy adjustment ( r = −.42, p<.01), and a positive correlation with feeling stigmatized because of the colostomy (r = .54, p<.01). Correlations between a general trait disgust measure and these outcomes were more modest. A structural equation model indicated that colostomy patients who had high disgust sensitivity felt more stigmatized, and this was in turn strongly related to lower life satisfaction. Concordantly, in the non-patient sample we observed that disgust sensitivity was a significant, positive predictor of wanting less contact with colostomy patients (r = .22, p < .01). PMID:17940585

  1. Diagnostic performance of influenza viruses and RSV rapid antigen detection tests in children in tertiary care.

    PubMed

    Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A

    2016-06-01

    Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Initial accuracy assessment of the modified S-LANSS for the detection of neuropathic orofacial pain conditions.

    PubMed

    Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin

    2017-01-01

    To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.

  3. Improved Automated Detection of Diabetic Retinopathy on a Publicly Available Dataset Through Integration of Deep Learning.

    PubMed

    Abràmoff, Michael David; Lou, Yiyue; Erginay, Ali; Clarida, Warren; Amelon, Ryan; Folk, James C; Niemeijer, Meindert

    2016-10-01

    To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.

  4. Skin prick testing and peanut-specific IgE can predict peanut challenge outcomes in preschoolchildren with peanut sensitization.

    PubMed

    Johannsen, H; Nolan, R; Pascoe, E M; Cuthbert, P; Noble, V; Corderoy, T; Franzmann, A; Loh, R; Prescott, S L

    2011-07-01

    The rise in peanut allergy is a source of considerable burden in the community. A growing number of preschoolchildren have been identified as peanut sensitized in the course of investigation of other allergic conditions. Although many have never knowingly ingested peanuts and their clinical reactivity is not known, it has been common practice to place these children on avoidance diets for many years. To determine the utility of skin prick tests (SPT) and fluorescent-enzyme immunoassays (FEIA) for identifying either peanut allergy or tolerance in preschoolchildren with peanut sensitization. Forty-nine preschoolchildren (<5 years of age) with peanut sensitization (SPT ≥ 2 mm or peanut-specific IgE ≥ 0.35 kU/L) but unknown clinical reactivity had graded open peanut challenges reaching a total of 11 g. A positive challenge was defined as an objective IgE-mediated reaction during challenge or the 2-h observation. Forty-nine percent (24/49) of children had positive challenges. An SPT of >7 mm on the day of challenge predicted a positive challenge with a sensitivity of 83% and a negative predictive value (NPV) of 84%. An FEIA of >2.0 kU/L showed a sensitivity of 79% and an NPV of 80%. Predicting challenge outcome from a combination of SPT and FEIA (SPT >7 and/or FEIA >2 is positive) increased sensitivity to 96% and NPV to 95%. At least half of preschoolchildren with peanut sensitization and no antecedent history of peanut ingestion can tolerate peanuts. A SPT<7 mm and FEIA<2 kU/L identify children most likely to tolerate peanut, with only a 5% likelihood of failing an oral challenge. This study assists clinicians considering challenges in very young peanut-sensitized children. © 2011 Blackwell Publishing Ltd.

  5. Profile of children with urinary tract infection and the utility of urine dipstick as a diagnostic tool.

    PubMed

    Ojha, A R; Aryal, U R

    2014-01-01

    Urinary tract infection is a common problem in children and its early diagnosis and treatment is important to prevent long-term complications. Urine dipstick can be an important tool in this respect. The aim of this study is to look at the utility of urine dipstick as a diagnostic tool for UTI and will also see the clinical profile of children with UTI and sensitivity pattern of antibiotics among the isolates of urine culture. Urine samples of all children below 14 years of age who were suspected of urinary tract infection were sent for routine microscopic examination and dipstick testing. Urine culture and sensitivity were sent for those samples that were tested positive for nitrite, leucocyte esterase activity or both. For every fifth sample, which is dipstick negative, a culture and sensitivity testing was done. Among 110 children enrolled, 32(29%) cases had significant bacteriuria. Out of 32 culture positive cases 18(56%) were female. Fever was the main complaint (62.5%)). Escherichia Coli was isolated in 81.25% of cases. Amikacin was sensitive in 93% and amoxicillinwas resistant in 82%. The sensitivity, specificity, positive predictive value, negative predictive value of nitrite test was 65%, 80%, 58%, 85% respectively; those of leucocyte esterase are 84%, 55%, 43%, 89% respectively; those for significant microscopic pyuria >10/hpf were 65%, 74%, 51%, 84% respectively. E. Coli is the commonest uropathogen in children with UTI. Amikacin is the most sensitive antibiotic against all the isolates. A positive dipstick both for nitrite and leucocyte esterase is associated with high sensitivity and specificity for urinary tract infection as compared to either of them positive alone. In addition, urine WBC ≥10/hpf is associated with high probability of UTI.

  6. Increased sensitivity of prolonged P-wave during exercise stress test in detection of angiographically documented coronary artery disease.

    PubMed

    Wsol, Agnieszka; Wydra, Wioletta; Chmielewski, Marek; Swiatowiec, Andrzej; Kuch, Marek

    2017-01-01

    A retrospective study was designed to investigate P-wave duration changes in exercise stress test (EST) for the prediction of angiographically documented substantial coronary artery disease (CAD). We analyzed 265 cases of patients, who underwent EST and subsequently coronary angiography. Analysis of P-wave duration was performed in leads II, V5 at rest, and in the recovery period. The sensitivity and specificity for the isolated ST-segment depression were only 31% and 76%, respectively. The combination of ST-depression with other exercise-induced clinical and electrocardio-graphic abnormalities (chest pain, ventricular arrhythmia, hypotension, left bundle branch block) was characterized by 41% sensitivity and 69% specificity. The combination of abnormal recovery P-wave duration (≥ 120 ms) with ST-depression and other exercise-induced abnormalities had 83% sensitivity but only 20% specificity. Combined analysis of increased delta P-wave duration, ST-depression and other exercise-induced abnormalities had 69% sensitivity and 42% specificity. Sensitivity and specificity of the increase in delta P-wave duration for left CAD was 69% and 47%, respectively, and for 3-vessel CAD 70% and 50%, respectively. The presence of arterial hypertension negatively influenced the prog-nostic value of P-wave changes in the stress test. The results of the study show that an addition of P-wave duration changes assessment to ST-depression analysis and other exercise-induced abnormalities increase sensitivity of EST, especially for left CAD and 3-vessel coronary disease. We have also provided evidence for the negative influence of the presence of arterial hypertension on the predictive value of P-wave changes in the stress test. (Cardiol J 2017; 24, 2: 159-166).

  7. Detectability and anatomical correlation of middle ear cholesteatoma using fused thin slice non-echo planar imaging diffusion-weighted image and magnetic resonance cisternography (FTS-nEPID).

    PubMed

    Kanoto, Masafumi; Sugai, Yukio; Hosoya, Takaaki; Toyoguchi, Yuuki; Konno, Yoshihiro; Watarai, Fumika; Ito, Tsukasa; Watanabe, Tomoo; Kakehata, Seiji

    2015-12-01

    Cholesteatomas show high intensity in diffusion-weighted imaging (DWI). We performed fused thin slice non-echo planar imaging (EPI) DWI and magnetic resonance cisternography (FTS-nEPID) for cholesteatoma patients to increase the detectability of FTS-nEPID for cholesteatoma. The subjects are 77 consecutive patients who underwent FTS-nEPID as a preoperative study (mean age: 53.3±21.8, 47 men and 30 women). Otorhinolaryngologists performed the operations. We anatomically classified the middle ear into four portions. A radiologist evaluated the images for cholesteatoma and assessed the anatomical invasive range in four portions using only FTS-nEPID. We classified large cholesteatomas that invaded more than three portions and small ones that invaded less than two portions based on the results obtained from surgery, and calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). For all cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 71%, 70%, 94%, and 27%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 49%, 85%, 77%, and 64%, respectively. For large cholesteatomas with an existing diagnosis, the sensitivity was 86%. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 51%, 57%, 88%, and 18%, respectively. For small cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 59%, 78%, 92%, and 30%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 40%, 85%, 60%, and 71%, respectively. FTS-nEPID may be useful for diagnosing cholesteatomas. Further research is needed for anatomical evaluation because there were many false-negative results. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Microbiology of liver abscesses and the predictive value of abscess gram stain and associated blood cultures.

    PubMed

    Chemaly, Roy F; Hall, Gerri S; Keys, Thomas F; Procop, Gary W

    2003-08-01

    Although rare, pyogenic liver abscesses are potentially fatal. We evaluated the predictive value of Gram stain of liver abscess aspirates and temporally associated blood cultures. Gram stains detected bacteria in 79% of the liver abscesses tested. The sensitivity and specificity of Gram stain of the liver abscesses were 90% and 100% for Gram-positive cocci (GPC) and 52% and 94% for Gram-negative bacilli (GNB). The sensitivities of the blood cultures for any GPC and GNB present in the liver abscess were 30% and 39%, respectively. Although, Gram stains and blood cultures offer incomplete detection of the microbial contents of pyogenic liver abscesses, both tests should always accompany liver abscess cultures.

  9. Development of a Pediatric Ebola Predictive Score, Sierra Leone1.

    PubMed

    Fitzgerald, Felicity; Wing, Kevin; Naveed, Asad; Gbessay, Musa; Ross, J C G; Checchi, Francesco; Youkee, Daniel; Jalloh, Mohamed Boie; Baion, David E; Mustapha, Ayeshatu; Jah, Hawanatu; Lako, Sandra; Oza, Shefali; Boufkhed, Sabah; Feury, Reynold; Bielicki, Julia; Williamson, Elizabeth; Gibb, Diana M; Klein, Nigel; Sahr, Foday; Yeung, Shunmay

    2018-02-01

    We compared children who were positive for Ebola virus disease (EVD) with those who were negative to derive a pediatric EVD predictor (PEP) score. We collected data on all children <13 years of age admitted to 11 Ebola holding units in Sierra Leone during August 2014-March 2015 and performed multivariable logistic regression. Among 1,054 children, 309 (29%) were EVD positive and 697 (66%) EVD negative, with 48 (5%) missing. Contact history, conjunctivitis, and age were the strongest positive predictors for EVD. The PEP score had an area under receiver operating characteristics curve of 0.80. A PEP score of 7/10 was 92% specific and 44% sensitive; 3/10 was 30% specific, 94% sensitive. The PEP score could correctly classify 79%-90% of children and could be used to facilitate triage into risk categories, depending on the sensitivity or specificity required.

  10. The relations of motivational traits with workplace deviance.

    PubMed

    Diefendorff, James M; Mehta, Kajal

    2007-07-01

    The authors developed and tested new theoretical relations between approach and avoidance motivational traits and deviant work behaviors. Approach motivation was divided into 3 traits: personal mastery (i.e., desire to achieve), competitive excellence (i.e., desire to perform better than others), and behavioral activation system (BAS) sensitivity (i.e., responsiveness to rewards). Avoidance motivation, which reflects one's sensitivity to negative stimuli and the desire to escape such stimuli, was conceptualized as a unitary construct. Using structural equation modeling, the authors examined the relations of these 4 motivational traits with interpersonal and organizational deviance in a sample of primarily part-time employees. For the approach motivation traits, results showed that personal mastery was negatively related to interpersonal and organizational deviance, BAS sensitivity was positively related to interpersonal and organizational deviance, and competitive excellence was unrelated to both types of workplace deviance. Finally, avoidance motivation was positively related to organizational deviance and interacted with organizational constraints to predict interpersonal deviance.

  11. Role of the Egami score to predict immunoglobulin resistance in Kawasaki disease among a Western Mediterranean population.

    PubMed

    Sánchez-Manubens, Judith; Antón, Jordi; Bou, Rosa; Iglesias, Estíbaliz; Calzada-Hernandez, Joan; Borlan, Sergi; Gimenez-Roca, Clara; Rivera, Josefa

    2016-07-01

    Kawasaki disease is an acute self-limited systemic vasculitis common in childhood. Intravenous immunoglobulin (IVIG) is an effective treatment, and it reduces the incidence of cardiac complications. Egami score has been validated to identify IVIG non-responder patients in Japanese population, and it has shown high sensitivity and specificity to identify these non-responder patients. Although its effectiveness in Japan, Egami score has shown to be ineffective in non-Japanese populations. The aim of this study was to apply the Egami score in a Western Mediterranean population in Catalonia (Spain). Observational population-based study that includes patients from all Pediatric Units in 33 Catalan hospitals, both public and private management, between January 2004 and March 2014. Sensitivity and specificity for the Egami score was calculated, and a logistic regression analysis of predictors of overall response to IVIG was also developed. Predicting IVIG resistance with a cutoff for Egami score ≥3 obtained 26 % sensitivity and 82 % specificity. Negative predictive value was 85 % and positive predictive value 22 %. This low sensitivity implies that three out of four non-responders will not be identified by the Egami score. Besides, logistic regression models did not found significance for the use of the Egami score to predict IVIG resistance in Catalan population although having an area under the ROC curve of 0.618 (IC 95 % 0.538-0.698, p < 0.001). Although regression models found an area under the ROC curve >0.5 to predict IVIG resistance, the low sensitivity excludes the Egami score as a useful tool to predict IVIG resistance in Catalan population.

  12. Artificial neural networks: Predicting head CT findings in elderly patients presenting with minor head injury after a fall.

    PubMed

    Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L

    2017-02-01

    To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    PubMed

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  14. Comparative evaluation of GPR versus APRI and FIB-4 in predicting different levels of liver fibrosis of chronic hepatitis B.

    PubMed

    Liu, D-P; Lu, W; Zhang, Z-Q; Wang, Y-B; Ding, R-R; Zhou, X-L; Huang, D; Li, X-F

    2018-05-01

    It is of great significance to develop and evaluate noninvasive indexes predicting the level of liver fibrosis. The aim of this study was to comparatively evaluate gamma-glutamyl transpeptidase-to-platelet ratio (GPR) versus aspartate aminotransferase-to-platelet ratio index (APRI) and fibrosis index based on 4 factors (FIB-4) in predicting different levels of liver fibrosis of chronic hepatitis B (CHB) within the framework of HBeAg-positive and HBeAg-negative patients. A total of 1157 HBeAg-positive and 859 HBeAg-negative CHB patients were enrolled, among whom the pathological stage ≥S2, ≥S3, ≥S4 were defined as significant fibrosis, extensive fibrosis and cirrhosis, respectively. Receiver operating characteristic (ROC) curves were used to evaluate the performance of GPR, APRI and FIB-4 in predicting different levels of liver fibrosis. In HBeAg-positive patients, the area under ROC curves (AUROCs) of GPR in predicting extensive fibrosis and cirrhosis were both significantly larger than those of APRI (P = .0001 and P < .0001). In HBeAg-negative patients, the AUROCs of GPR in predicting significant fibrosis and cirrhosis were significantly larger than those of FIB-4 (P = .0006 and P = .0041). The AUROC of GPR in predicting extensive fibrosis was significantly larger than that of APRI and FIB-4 (P = .0320 and P = .0018). Using a cut-off of GPR > 0.500 as standard, the sensitivities and specificities of GPR in predicting significant fibrosis in HBeAg-positive patients were 59.6% and 81.2%, and for cirrhosis 80.9% and 63.8%, respectively; and those of HBeAg-negative patients were 60.3% and 78.3%, 84.5% and 66.1%, respectively. Regardless of HBeAg-positive or HBeAg-negative status, GPR had the best performance in predicting different levels of liver fibrosis. © 2017 John Wiley & Sons Ltd.

  15. Comparison of mortality prediction models in burns ICU patients in Pinderfields Hospital over 3 years.

    PubMed

    Douglas, Helen E; Ratcliffe, Andrew; Sandhu, Rajdeep; Anwar, Umair

    2015-02-01

    Many different burns mortality prediction models exist; however most agree that important factors that can be weighted include the age of the patient, the total percentage of body surface area burned and the presence or absence of smoke inhalation. A retrospective review of all burns primarily admitted to Pinderfields Burns ICU under joint care of burns surgeons and intensivists for the past 3 years was completed. Predicted mortality was calculated using the revised Baux score (2010), the Belgian Outcome in Burn Injury score (2009) and the Boston group score by Ryan et al. (1998). Additionally 28 of the 48 patients had APACHE II scores recorded on admission and the predicted and actual mortality of this group were compared. The Belgian score had the highest sensitivity and negative predictive value (72%/85%); followed by the Boston score (66%/78%) and then the revised Baux score (53%/70%). APACHE II scores had higher sensitivity (81%) and NPV (92%) than any of the burns scores. In our group of burns ICU patients the Belgian model was the most sensitive and specific predictor of mortality. In our subgroup of patients with APACHE II data, this score more accurately predicted survival and mortality. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  16. Inequality across Consonantal Contrasts in Speech Perception: Evidence from Mismatch Negativity

    ERIC Educational Resources Information Center

    Cornell, Sonia A.; Lahiri, Aditi; Eulitz, Carsten

    2013-01-01

    The precise structure of speech sound representations is still a matter of debate. In the present neurobiological study, we compared predictions about differential sensitivity to speech contrasts between models that assume full specification of all phonological information in the mental lexicon with those assuming sparse representations (only…

  17. Anxiety and Error Monitoring: Increased Error Sensitivity or Altered Expectations?

    ERIC Educational Resources Information Center

    Compton, Rebecca J.; Carp, Joshua; Chaddock, Laura; Fineman, Stephanie L.; Quandt, Lorna C.; Ratliff, Jeffrey B.

    2007-01-01

    This study tested the prediction that the error-related negativity (ERN), a physiological measure of error monitoring, would be enhanced in anxious individuals, particularly in conditions with threatening cues. Participants made gender judgments about faces whose expressions were either happy, angry, or neutral. Replicating prior studies, midline…

  18. [Clinical benefit of HCV core antigen assay in patients receiving interferon and ribavirin combination therapy].

    PubMed

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Saito, Hidetsugu

    2006-02-01

    A highly sensitive second generation HCV core antigen assay has recently been developed. We compared viral disappearance and kinetics data between commercially available core antigen assays, Lumipulse Ortho HCV Ag, and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor Test, Version 2 to estimate the predictive benefit of sustained viral response (SVR) and non-SVR in 59 patients treated with interferon and ribavirin combination therapy. We found a good correlation between HCV core Ag and HCV RNA level regardless of genotype. Although the sensitivity of the core antigen assay was lower than PCR, the dynamic range was broader than that of the PCR assay, so that we did not need to dilute the samples in 59 patients. We detected serial decline of core Ag levels in 24 hrs, 7 days and 14 days after interferon combination therapy. The decline of core antigen levels was significant in SVR patients compared to non-SVR as well as in genotype 2a, 2b patients compared to 1b. Core antigen-negative on day 1 could predict all 10 SVR patients (PPV = 100%), whereas RNA-negative could predict 22 SVR out of 25 on day 14 (PPV = 88.0%). None of the patients who had detectable serum core antigen on day 14 became SVR(NPV = 100%), although NPV was 91.2% on RNA negativity. An easy, simple, low cost new HCV core antigen detecting system seems to be useful for assessing and monitoring IFN treatment for HCV.

  19. Comparative study of RetCamRetCam II vs. binocular ophthalmoscopy in a screening program for retinopathy of prematurity.

    PubMed

    Tejada-Palacios, P; Zarratea, L; Moral, M; de la Cruz-Bértolo, J

    2015-08-01

    To determine the performance of RetCam vs. binocular ophthalmoscopy (BIO) in a screening program for retinopathy of prematurity (ROP). Observational comparative study with prospective data collection. Examinations with RetCam (n=169) were performed on 83 infants included in a screening program for ROP and stored for analysis at a later stage. An experienced ophthalmologist examined the ocular fundus with binocular indirect ophthalmoscopy (BIO). The RetCam images were assessed for the presence of ROP, zone, grade, and presence of plus disease. RetCam and BIO data were compared by visually to estimate sensitivity, specificity, positive (VPP) and negative (VPN) predictive values. ROP disease was detected in 108 eyes with BIO, and in 74 with RetCam. Out of 306 eyes examined with RetCam, false negative results were found in 34 eyes, with no false positives. Sensitivity of RetCam exam vs. BIO was 0.68, and specificity was 0.99. Positive predictive value was 0.93 and negative predictive value was 0.85. All 34 ROP cases not detected with RetCam were in zone III or outer zone II. They were all mild and regressed spontaneously. No threshold ROP was missed with RetCam. Binocular indirect ophthalmoscopy is the reference method for the diagnosis of ROP. RetCam may be used as an alternative for ROP screening. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  20. The role of postoperative Tc-99m pertechnetate scintigraphy in estimation of remnant mass and prediction of successful ablation in patients with differentiated thyroid cancer.

    PubMed

    Ozdemir, Didem; Cuhaci, Fatma N; Ozdemir, Elif; Aydin, Cevdet; Ersoy, Reyhan; Turkolmez, Seyda; Cakir, Bekir

    2016-06-01

    Surgery and radioactive iodine (RAI) ablation constitute the mainstay of the treatment of differentiated thyroid carcinoma (DTC). In this study, we aimed to evaluate the diagnostic value of postoperative early Tc-99m pertechnetate scanning to detect remnant thyroid tissue and predict ablation success. DTC patients evaluated with postoperative Tc-99m pertechnetate scintigraphy and treated with RAI between January 2007 and December 2014 were recruited. The results of Tc-99m pertechnetate scanning were compared with therapeutic I-131 whole-body scanning (TxWBS) and diagnostic I-131 whole-body scanning (DxWBS) performed 6-9 months after RAI. There were 154 (21.5%) male and 563 (78.5%) female patients, with a mean age of 49.11±12.35 years. Postoperative Tc-99m pertechnetate scanning was positive in 499 patients (69.6%) and negative in 218 (30.4%) patients. There were 673 (93.9%) patients with a positive TxWBS scan and 44 (6.1%) patients with negative TxWBS scan. Considering TxWBS as the standard test, sensitivity, specificity, positive predictive value, and negative predictive value of Tc-99m pertechnetate scanning were 72.2, 70.5, 97.4, and 14.2%, respectively. DxWBS was positive in 57 (9.0%) and negative in 564 (91%) patients. Ablation dose was higher and preablation thyroglobulin was lower in patients with negative DxWBS (P=0.001 and 0.04, respectively). Overall, 171 (92.9%) of 184 patients with negative Tc-99m pertechnetate had negative DxWBS. Postoperative Tc-99m pertechnetate scintigraphy has a high positive predictive value to detect remnant tissue in patients with DTC. Although negative Tc-99m pertechnetate scanning does not indicate removal of all thyroid tissue, it is related to successful ablation in more than 90% of patients.

  1. Investigation of NS3 Protease Resistance-Associated Variants and Phenotypes for the Prediction of Treatment Response to HCV Triple Therapy.

    PubMed

    Dietz, Julia; Rupp, Daniel; Susser, Simone; Vermehren, Johannes; Peiffer, Kai-Henrik; Filmann, Natalie; Bon, Dimitra; Kuntzen, Thomas; Mauss, Stefan; Grammatikos, Georgios; Perner, Dany; Berkowski, Caterina; Herrmann, Eva; Zeuzem, Stefan; Bartenschlager, Ralf; Sarrazin, Christoph

    2016-01-01

    Triple therapy of chronic hepatitis C virus (HCV) infection with boceprevir (BOC) or telaprevir (TVR) leads to virologic failure in many patients which is often associated with the selection of resistance-associated variants (RAVs). These resistance profiles are of importance for the selection of potential rescue treatment options. In this study, we sequenced baseline NS3 RAVs population-based and investigated the sensitivity of NS3 phenotypes in an HCV replicon assay together with clinical factors for a prediction of treatment response in a cohort of 165 German and Swiss patients treated with a BOC or TVR-based triple therapy. Overall, the prevalence of baseline RAVs was low, although the frequency of RAVs was higher in patients with virologic failure compared to those who achieved a sustained virologic response (SVR) (7% versus 1%, P = 0.06). The occurrence of RAVs was associated with a resistant NS3 quasispecies phenotype (P<0.001), but the sensitivity of phenotypes was not associated with treatment outcome (P = 0.2). The majority of single viral and host predictors of SVR was only weakly associated with treatment response. In multivariate analyses, low AST levels, female sex and an IFNL4 CC genotype were independently associated with SVR. However, a combined analysis of negative predictors revealed a significantly lower overall number of negative predictors in patients with SVR in comparison to individuals with virologic failure (P<0.0001) and the presence of 2 or less negative predictors was indicative for SVR. These results demonstrate that most single baseline viral and host parameters have a weak influence on the response to triple therapy, whereas the overall number of negative predictors has a high predictive value for SVR.

  2. Context-sensitivity of the feedback-related negativity for zero-value feedback outcomes.

    PubMed

    Pfabigan, Daniela M; Seidel, Eva-Maria; Paul, Katharina; Grahl, Arvina; Sailer, Uta; Lanzenberger, Rupert; Windischberger, Christian; Lamm, Claus

    2015-01-01

    The present study investigated whether the same visual stimulus indicating zero-value feedback (€0) elicits feedback-related negativity (FRN) variation, depending on whether the outcomes correspond with expectations or not. Thirty-one volunteers performed a monetary incentive delay (MID) task while EEG was recorded. FRN amplitudes were comparable and more negative when zero-value outcome deviated from expectations than with expected gain or loss, supporting theories emphasising the impact of unexpectedness and salience on FRN amplitudes. Surprisingly, expected zero-value outcomes elicited the most negative FRNs. However, source localisation showed that such outcomes evoked less activation in cingulate areas than unexpected zero-value outcomes. Our study illustrates the context dependency of identical zero-value feedback stimuli. Moreover, the results indicate that the incentive cues in the MID task evoke different reward prediction error signals. These prediction signals differ in FRN amplitude and neuronal sources, and have to be considered in the design and interpretation of future studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Discovering Peripheral Arterial Disease Cases from Radiology Notes Using Natural Language Processing

    PubMed Central

    Savova, Guergana K.; Fan, Jin; Ye, Zi; Murphy, Sean P.; Zheng, Jiaping; Chute, Christopher G.; Kullo, Iftikhar J.

    2010-01-01

    As part of the Electronic Medical Records and Genomics Network, we applied, extended and evaluated an open source clinical Natural Language Processing system, Mayo’s Clinical Text Analysis and Knowledge Extraction System, for the discovery of peripheral arterial disease cases from radiology reports. The manually created gold standard consisted of 223 positive, 19 negative, 63 probable and 150 unknown cases. Overall accuracy agreement between the system and the gold standard was 0.93 as compared to a named entity recognition baseline of 0.46. Sensitivity for the positive, probable and unknown cases was 0.93–0.96, and for the negative cases was 0.72. Specificity and negative predictive value for all categories were in the 90’s. The positive predictive value for the positive and unknown categories was in the high 90’s, for the negative category was 0.84, and for the probable category was 0.63. We outline the main sources of errors and suggest improvements. PMID:21347073

  4. Sensitivity of negative subsequent memory and task-negative effects to age and associative memory performance.

    PubMed

    de Chastelaine, Marianne; Mattson, Julia T; Wang, Tracy H; Donley, Brian E; Rugg, Michael D

    2015-07-01

    The present fMRI experiment employed associative recognition to investigate the relationships between age and encoding-related negative subsequent memory effects and task-negative effects. Young, middle-aged and older adults (total n=136) were scanned while they made relational judgments on visually presented word pairs. In a later memory test, the participants made associative recognition judgments on studied, rearranged (items studied on different trials) and new pairs. Several regions, mostly localized to the default mode network, demonstrated negative subsequent memory effects in an across age-group analysis. All but one of these regions also demonstrated task-negative effects, although there was no correlation between the size of the respective effects. Whereas negative subsequent memory effects demonstrated a graded attenuation with age, task-negative effects declined markedly between the young and the middle-aged group, but showed no further reduction in the older group. Negative subsequent memory effects did not correlate with memory performance within any age group. By contrast, in the older group only, task-negative effects predicted later memory performance. The findings demonstrate that negative subsequent memory and task-negative effects depend on dissociable neural mechanisms and likely reflect distinct cognitive processes. The relationship between task-negative effects and memory performance in the older group might reflect the sensitivity of these effects to variations in amount of age-related neuropathology. This article is part of a Special Issue entitled SI: Memory. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Middle cerebral artery peak systolic velocity to predict fetal hemoglobin levels in twin anemia-polycythemia sequence.

    PubMed

    Slaghekke, F; Pasman, S; Veujoz, M; Middeldorp, J M; Lewi, L; Devlieger, R; Favre, R; Lopriore, E; Oepkes, D

    2015-10-01

    To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P < 0.001). The sensitivity of MCA-PSV ≥ 1.5 MoM to predict severe anemia (Hb deficit > 5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  6. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    PubMed

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed sonography is positive.

  7. [Accuracy of three methods for the rapid diagnosis of oral candidiasis].

    PubMed

    Lyu, X; Zhao, C; Yan, Z M; Hua, H

    2016-10-09

    Objective: To explore a simple, rapid and efficient method for the diagnosis of oral candidiasis in clinical practice. Methods: Totally 124 consecutive patients with suspected oral candidiasis were enrolled from Department of Oral Medicine, Peking University School and Hospital of Stomatology, Beijing, China. Exfoliated cells of oral mucosa and saliva or concentrated oral rinse) obtained from all participants were tested by three rapid smear methods(10% KOH smear, gram-stained smear, Congo red stained smear). The diagnostic efficacy(sensitivity, specificity, Youden's index, likelihood ratio, consistency, predictive value and area under curve(AUC) of each of the above mentioned three methods was assessed by comparing the results with the gold standard(combination of clinical diagnosis, laboratory diagnosis and expert opinion). Results: Gram-stained smear of saliva(or concentrated oral rinse) demonstrated highest sensitivity(82.3%). Test of 10%KOH smear of exfoliated cells showed highest specificity(93.5%). Congo red stained smear of saliva(or concentrated oral rinse) displayed highest diagnostic efficacy(79.0% sensitivity, 80.6% specificity, 0.60 Youden's index, 4.08 positive likelihood ratio, 0.26 negative likelihood ratio, 80% consistency, 80.3% positive predictive value, 79.4% negative predictive value and 0.80 AUC). Conclusions: Test of Congo red stained smear of saliva(or concentrated oral rinse) could be used as a point-of-care tool for the rapid diagnosis of oral candidiasis in clinical practice. Trial registration: Chinese Clinical Trial Registry, ChiCTR-DDD-16008118.

  8. The meaning of diagnostic test results: a spreadsheet for swift data analysis.

    PubMed

    Maceneaney, P M; Malone, D E

    2000-03-01

    To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. Microsoft Excel(TM)was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. This spreadsheet can be used on desktop and palmtop computers. The MS Excel(TM)version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. Copyright 2000 The Royal College of Radiologists.

  9. The use of the NDDI-E in Arabic to identify symptoms of depression of moderate or greater severity in people with epilepsy.

    PubMed

    Alkhamees, Hadeel A; Selai, Caroline E; Shorvon, Simon D; Kanner, Andres M

    2014-03-01

    The aims of the current study were to translate and to validate the NDDI-E to the Arabic language to be used as a screening instrument to identify moderately severe symptoms of depression in people with epilepsy. The English version of the NDDI-E was translated to Arabic and back translated to English by two independent translators. A total of 51 patients, aged 18-56years old, with a diagnosis of epilepsy, completed the Arabic versions of the Beck Depression Inventory (BDI-II) and the NDDI-E. Patients with BDI scores >20 were considered to be suffering from moderately severe depressive symptoms. Cutoff scores, sensitivity, specificity, and positive and negative predictive values of the NDDI-E to identify symptomatic patients on the BDI were calculated. A sensitivity of 93.33% and a specificity of 94.44% were found with NDDI-E total scores >15. The positive predictive value was 87.5%, and the negative predictive value was 97.14%. Spearman's rank correlation between the BDI and the NDDI-E was high (r=.78, p=0.000, N=51). Internal consistency was at 0.926 (Cronbach's alpha). The Arabic version of the NDDI-E appears to be a reliable and sensitive instrument in the identification of moderately severe or severe depressive symptoms in people with epilepsy, and it can be used with all Arabic-speaking patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Dysphagia risk assessment in acute left-hemispheric middle cerebral artery stroke.

    PubMed

    Somasundaram, Sriramya; Henke, Christian; Neumann-Haefelin, Tobias; Isenmann, Stefan; Hattingen, Elke; Lorenz, Matthias W; Singer, Oliver C

    2014-01-01

    Bedside evaluation of dysphagia may be challenging in left middle cerebral artery (MCA) stroke due to frequently existing aphasia. Here we analyse the predictive value of common bedside screening tests and of two items of cortical dysfunction, aphasia and buccofacial apraxia (BFA), for the detection of dysphagia. We prospectively examined 67 consecutive patients with clinical and imaging evidence of acute (<72 h) left MCA stroke. Dysphonia, dysarthria, abnormal volitional cough and abnormal gag reflex were assessed followed by a standardized 50-ml water-swallowing test determining the symptoms cough and voice change after swallow. Aphasia and BFA were assessed according to defined criteria. Fibre-optic endoscopic evaluation of swallowing (FEES) was performed for validation of dysphagia. 41 (61%) patients had FEES-proven dysphagia. Abnormal gag reflex, abnormal volitional cough, cough after swallow, aphasia and BFA were significantly more frequent in dysphagic as compared to non-dysphagic patients, while dysphonia, dysarthria and voice change after swallow were not. Aphasia and BFA had the highest sensitivity (97 and 78%, respectively) and high negative predictive values (89 and 68%, respectively) for dysphagia. Multivariate regression analysis did not identify an independent predictor of dysphagia. In left MCA stroke, the sensitivity and specificity of common bedside dysphagia screening methods are low. In contrast, aphasia and BFA have a high sensitivity and high negative predictive power, presumably due to the neuro-anatomical overlap between cortical regions involved in swallowing, speech production, imitation and voluntary movement control. © 2014 S. Karger AG, Basel.

  11. On Pulsating and Cellular Forms of Hydrodynamic Instability in Liquid-Propellant Combustion

    NASA Technical Reports Server (NTRS)

    Margolis, Stephen B.; Sacksteder, Kurt (Technical Monitor)

    1998-01-01

    An extended Landau-Levich model of liquid-propellant combustion, one that allows for a local dependence of the burning rate on the (gas) pressure at the liquid-gas interface, exhibits not only the classical hydrodynamic cellular instability attributed to Landau but also a pulsating hydrodynamic instability associated with sufficiently negative pressure sensitivities. Exploiting the realistic limit of small values of the gas-to-liquid density ratio p, analytical formulas for both neutral stability boundaries may be obtained by expanding all quantities in appropriate powers of p in each of three distinguished wave-number regimes. In particular, composite analytical expressions are derived for the neutral stability boundaries A(sub p)(k), where A, is the pressure sensitivity of the burning rate and k is the wave number of the disturbance. For the cellular boundary, the results demonstrate explicitly the stabilizing effect of gravity on long-wave disturbances, the stabilizing effect of viscosity (both liquid and gas) and surface tension on short-wave perturbations, and the instability associated with intermediate wave numbers for negative values of A(sub p), which is characteristic of many hydroxylammonium nitrate-based liquid propellants over certain pressure ranges. In contrast, the pulsating hydrodynamic stability boundary is insensitive to gravitational and surface-tension effects but is more sensitive to the effects of liquid viscosity because, for typical nonzero values of the latter, the pulsating boundary decreases to larger negative values of A(sub p) as k increases through O(l) values. Thus, liquid-propellant combustion is predicted to be stable (that is, steady and planar) only for a range of negative pressure sensitivities that lie below the cellular boundary that exists for sufficiently small negative values of A(sub p) and above the pulsating boundary that exists for larger negative values of this parameter.

  12. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    PubMed

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (<60%) for other more specific categories. Similarly, interreader agreement (kappa value) was moderate to substantial (40-80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus and E. coli, but was lower for other categories. The Tri-Plate had a higher sensitivity, accuracy, and negative predictive value for Streptococcus spp., and higher interreader agreement for some of the more specific categories. Our conclusion was that Bi-Plate and Tri-Plate results will be most reliable when used to classify infections in broad diagnostic categories such NG, GP, or GN. The Bi-Plate and Tri-Plate will have intermediate ability to identify infections as being caused by Staphylococcus spp., Streptococcus spp., or Staph. aureus. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Developmental history of care and control, depression and anger: Correlates of maternal sensitivity in toddlerhood.

    PubMed

    Burrous, C Emma; Crockenberg, Susan C; Leerkes, Esther M

    2009-03-01

    This study examined maternal sensitivity in response to toddler distress in relation to mothers' childhood care and control experiences with parents, maternal depression, and maternal anger. Fifty-two mothers and infants participated. Mothers reported childhood care and control experiences prenatally. At 2½ years, mothers reported depressive symptoms and anger on questionnaires, and reported maternal behavior in a daily diary for 1 week, yielding ratings of maternal sensitivity to fear and anger. Results were as follows: (a) Mothers' acceptance during childhood correlated negatively with both maternal depression and maternal anger, and positively with maternal sensitivity to fear at 2½ years; (b) maternal anger mediated the association between childhood care and maternal sensitivity to fear at 2½ years; and (c) the interaction of maternal and paternal control during childhood predicted maternal sensitivity to anger at 2½ years, controlling for maternal education. When maternal control was low, paternal control was positively associated with maternal sensitivity to anger whereas when maternal control was high, paternal control was negatively associated with maternal sensitivity to anger. Results are discussed in relation to prior studies, with particular emphasis on attachment theory. Implications for preventive intervention efforts are considered. Copyright © 2009 Michigan Association for Infant Mental Health.

  14. Ultrasonic vocalizations, predictability and sensorimotor gating in the rat

    PubMed Central

    Webber, Emily S.; Mankin, David E.; McGraw, Justin J.; Beckwith, Travis J.; Cromwell, Howard C.

    2013-01-01

    Prepulse inhibition (PPI) is a measure of sensorimotor gating in diverse groups of animals including humans. Emotional states can influence PPI in humans both in typical subjects and in individuals with mental illness. Little is known about emotional regulation during PPI in rodents. We used ultrasonic vocalization recording to monitor emotional states in rats during PPI testing. We altered the predictability of the PPI trials to examine any alterations in gating and emotional regulation. We also examined PPI in animals selectively bred for high or low levels of 50 kHz USV emission. Rats emitted high levels of 22 kHz calls consistently throughout the PPI session. USVs were sensitive to prepulses during the PPI session similar to startle. USV rate was sensitive to predictability among the different levels tested and across repeated experiences. Startle and inhibition of startle were not affected by predictability in a similar manner. No significant differences for PPI or startle were found related the different levels of predictability; however, there was a reduction in USV signals and an enhancement of PPI after repeated exposure. Animals selectively bred to emit high levels of USVs emitted significantly higher levels of USVs during the PPI session and a reduced ASR compared to the low and random selective lines. Overall, the results support the idea that PPI tests in rodents induce high levels of negative affect and that manipulating emotional styles of the animals alters the negative impact of the gating session as well as the intensity of the startle response. PMID:23850353

  15. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    PubMed

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  16. Using a bayesian latent class model to evaluate the utility of investigating persons with negative polymerase chain reaction results for pertussis.

    PubMed

    Tarr, Gillian A M; Eickhoff, Jens C; Koepke, Ruth; Hopfensperger, Daniel J; Davis, Jeffrey P; Conway, James H

    2013-07-15

    Pertussis remains difficult to control. Imperfect sensitivity of diagnostic tests and lack of specific guidance regarding interpretation of negative test results among patients with compatible symptoms may contribute to its spread. In this study, we examined whether additional pertussis cases could be identified if persons with negative pertussis test results were routinely investigated. We conducted interviews among 250 subjects aged ≤18 years with pertussis polymerase chain reaction (PCR) results reported from 2 reference laboratories in Wisconsin during July-September 2010 to determine whether their illnesses met the Centers for Disease Control and Prevention's clinical case definition (CCD) for pertussis. PCR validity measures were calculated using the CCD as the standard for pertussis disease. Two Bayesian latent class models were used to adjust the validity measures for pertussis detectable by 1) culture alone and 2) culture and/or more sensitive measures such as serology. Among 190 PCR-negative subjects, 54 (28%) had illnesses meeting the CCD. In adjusted analyses, PCR sensitivity and the negative predictive value were 1) 94% and 99% and 2) 43% and 87% in the 2 types of models, respectively. The models suggested that public health follow-up of reported pertussis patients with PCR-negative results leads to the detection of more true pertussis cases than follow-up of PCR-positive persons alone. The results also suggest a need for a more specific pertussis CCD.

  17. Early prediction of blonanserin response in Japanese patients with schizophrenia.

    PubMed

    Kishi, Taro; Matsuda, Yuki; Fujita, Kiyoshi; Iwata, Nakao

    2014-01-01

    Blonanserin is a second-generation antipsychotic used for the treatment of schizophrenia in Japan and Korea. The present study aimed to examine early prediction of blonanserin in patients with schizophrenia. An 8-week, prospective, single-arm, flexible-dose clinical trial of blonanserin in patients with schizophrenia was conducted under real-world conditions. The inclusion criteria were antipsychotic naïve, and first-episode schizophrenia patients or schizophrenia patients with no consumption of any antipsychotic medication for more than 4 weeks before enrollment in this study. The positive predictive value, negative predictive value, sensitivity, specificity, and predictive power were calculated for the response status at week 4 to predict the subsequent response at week 8. Thirty-seven patients were recruited (56.8% of them had first-episode schizophrenia), and 28 (75.7%) completed the trial. At week 8, blonanserin was associated with a significant improvement in the Positive and Negative Syndrome Scale (PANSS) total score (P<0.0001) and in positive (P<0.0001), negative (P<0.0001), and general subscale scores (P<0.0001). In terms of percentage improvement of PANSS total scores from baseline to week 8, 64.9% of patients showed a ≥20% reduction in the PANSS total score and 48.6% showed a ≥30% reduction. However, 8.1% of patients experienced at least one adverse event. Using the 20% reduction in the PANSS total score at week 4 as a definition of an early response, the negative predictive values for later responses (ie, reductions of ≥30 and ≥40 in the PANSS total scores) were 88.9% and 94.1%, respectively. The specificities were 80.0% and 51.6%, respectively. Our results suggest that the blonanserin response at week 4 could predict the later response at week 8.

  18. Early prediction of blonanserin response in Japanese patients with schizophrenia

    PubMed Central

    Kishi, Taro; Matsuda, Yuki; Fujita, Kiyoshi; Iwata, Nakao

    2014-01-01

    Background Blonanserin is a second-generation antipsychotic used for the treatment of schizophrenia in Japan and Korea. The present study aimed to examine early prediction of blonanserin in patients with schizophrenia. Methods An 8-week, prospective, single-arm, flexible-dose clinical trial of blonanserin in patients with schizophrenia was conducted under real-world conditions. The inclusion criteria were antipsychotic naïve, and first-episode schizophrenia patients or schizophrenia patients with no consumption of any antipsychotic medication for more than 4 weeks before enrollment in this study. The positive predictive value, negative predictive value, sensitivity, specificity, and predictive power were calculated for the response status at week 4 to predict the subsequent response at week 8. Results Thirty-seven patients were recruited (56.8% of them had first-episode schizophrenia), and 28 (75.7%) completed the trial. At week 8, blonanserin was associated with a significant improvement in the Positive and Negative Syndrome Scale (PANSS) total score (P<0.0001) and in positive (P<0.0001), negative (P<0.0001), and general subscale scores (P<0.0001). In terms of percentage improvement of PANSS total scores from baseline to week 8, 64.9% of patients showed a ≥20% reduction in the PANSS total score and 48.6% showed a ≥30% reduction. However, 8.1% of patients experienced at least one adverse event. Using the 20% reduction in the PANSS total score at week 4 as a definition of an early response, the negative predictive values for later responses (ie, reductions of ≥30 and ≥40 in the PANSS total scores) were 88.9% and 94.1%, respectively. The specificities were 80.0% and 51.6%, respectively. Conclusion Our results suggest that the blonanserin response at week 4 could predict the later response at week 8. PMID:25285009

  19. Assessment of HPV-mRNA test to predict recurrent disease in patients previously treated for CIN 2/3.

    PubMed

    Frega, Antonio; Sesti, Francesco; Lombardi, Danila; Votano, Sergio; Sopracordevole, Francesco; Catalano, Angelica; Milazzo, Giusi Natalia; Lombardo, Riccardo; Assorgi, Chiara; Olivola, Sara; Chiusuri, Valentina; Ricciardi, Enzo; French, Deborah; Moscarini, Massimo

    2014-05-01

    The use of HPV-mRNA test in the follow-up after LEEP is still matter of debate, with regard to its capacity of prediction relapse. The aim of the present study is to evaluate the reliability of HPV-mRNA test to predict the residual and recurrent disease, and its accuracy in the follow-up of patients treated for CIN 2/3. Multicenter prospective cohort study. Patients who underwent LEEP after a biopsy diagnosing CIN 2/3 were followed at 3, 6, 12, 24 and 36 months. Each check up included cytology, colposcopy, HPV-DNA test (LiPA) and HPV-mRNA test (PreTect HPV Proofer Kit NorChip). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), of HPV-DNA test and HPV-mRNA test to predict relapse, recurrent and residual disease. Using multiple logistic regression, the statistical significant variables as assessed in univariate analysis were entered and investigated as predictors of relapse disease. The mRNA-test in predicting a residual disease had a sensitivity of 52% and a NPV of 91%, whereas DNA-test had 100% and 100%, respectively. On the contrary in the prediction of recurrent disease mRNA-test had a sensitivity and a NPV of 73.5% and 97%, whereas DNA-test had 44% and 93%. On the multivariate analysis, age, cytology, HPV DNA and mRNA test achieved the role of independent predictors of relapse. HPV-mRNA test has a higher sensitivity and a higher NPV in predicting recurrent disease, for this reason it should be used in the follow-up of patients treated with LEEP for CIN 2/3 in order to individualize the timing of check up. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Identifying women who are afraid of giving birth: A comparison of the fear of birth scale with the WDEQ-A in a large Australian cohort.

    PubMed

    Haines, H M; Pallant, J F; Fenwick, J; Gamble, J; Creedy, D K; Toohill, J; Hildingsson, I

    2015-12-01

    The WDEQ-A is the most widely used measure of childbirth fear in pregnant women; however there is increasing discussion in the literature that simpler, more culturally transferrable tools may offer a better solution to identifying fearful women in clinical practice. To compare the two item Fear of Birth Scale (FOBS) with the 33 item WDEQ-A in a large cohort of Australian pregnant women. Self-report questionnaires during second trimester including Wijma Delivery Expectancy Questionnaire (WDEQ-A) and Fear of Birth Scale (FOBS). Correlation of FOBS and WDEQ-A was tested using Spearman's correlation coefficients. Receiver operating characteristic (ROC) curve assessed the sensitivity and specificity of possible cut-points on the FOBS against WDEQ-A cut-point of ≥85. Sensitivity, specificity, positive and negative predictive values were determined. Fearful and non-fearful women as classified by both instruments were compared for differences in demographic, psycho-social and obstetric characteristics. 1410 women participated. The correlation between the instruments was strong (Spearman's Rho = 0.66, p < 0.001). The area under the ROC was 0.89 indicating high sensitivity with a FOBS cut-point of 54. Sensitivity was 89%, specificity 79% and Youden index 0.68. Positive predictive value was 85% and negative predictive value 79%. Both instruments identified high fear as significantly associated with first time mothers, previous emergency caesarean and women with self-reported anxiety and/or depression. Additionally FOBS identified a significant association between fearful women and preference for caesarean. This study supports the use of the FOBS in clinical practice to identify childbirth fear in pregnant women. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  1. Diagnostic capability of scanning laser polarimetry with variable cornea compensator in Indian patients with early primary open-angle glaucoma.

    PubMed

    Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi

    2008-07-01

    To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.

  2. Influence of hormonal therapy in prostate cancer patients undergoing [18F]fluoromethyl choline PET/CT: a retrospective study.

    PubMed

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Isabella; Buresta, Tommaso; Radicchia, Valentina; Fravolini, Mario L; Ferretti, Francesca; Bellavita, Rita; Mearini, Luigi; Scialpi, Michele; Aristei, Cynthia; Pelliccia, Gianfranco

    2016-12-01

    Patients with suspected recurrence of prostate cancer undergoing [18F]fluoromethyl choline ([18F]FCH) PET/CT were retrospectively evaluated to investigate the influence of hormonal therapy (HT) in [18F]FCH uptake. [18F]FCH PET/CT was performed in 102 surgically treated patients with suspected recurrence (PSA increase >0.2 ng/mL) of prostate cancer, divided in two groups: under HT (N.=54) and without HT (N.=48) at the time of PET scanning. PET/CT was carried out by an integrated system (Biograph 6, CTI/Siemens, Knoxville, TN, USA) intravenously by administering 4.1 MBq/kg of [18F]FCH to each patient; images were acquired 60 minutes later. On the total number of patients, 66 were found to be true positives (TP), 9 false positives (FP), 5 false negatives (FN) and 22 true negatives (TN), sensitivity to [18F]FCH PET/CT was 93%, specificity 71%, accuracy 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 81%. In the 54 patients under HT, 38 were TP, 6 FP, 3 FN and 7 TN, sensitivity was 93%, specificity 54%, accuracy 83%, PPV 86% and NPV was 70%. In the 48 patients receiving no HT, 28 were TP, 3 FP, 2 FN and 15 TN, sensitivity was 93%, specificity 83%, accuracy 90%, PPV 90% and NPV 88%. A χ2 test showed that sensitivity, accuracy and PPV did not differ among patients with and without HT, while specificity and NPV were significantly lower (P<0.001) in HT treated patients. Sensitivity, accuracy and PPV were similar in patients with and without HT. Specificity and NPV were reduced in patients under HT, but further data are necessary to support if this reduction is casual or related to therapy and it could be confirmed in a larger series of patients.

  3. Assessment of the Role of Different Imaging Modalities with Emphasis on Fdg Pet/Ct in the Management of Well Differentiated Thyroid Cancer (WDTC).

    PubMed

    Kendi A, Tuba Karagulle; Mudalegundi, Shwetha; Switchenko, Jeffrey; Lee, Daniel; Halkar, Raghuveer; Chen, Amy Y

    2016-01-01

    Positron emission tomography/computed tomography is suggested to have a role in detection of iodine negative recurrence in well differentiated thyroid cancer. The aim of this study is to identify role of different imaging modalities in the management of well differentiated thyroid cancer. We reviewed 900 well differentiated thyroid cancer patients after post-thyroidectomy who underwent recombinant human thyroid stimulating hormone stimulated Sodium Iodide I 131 imaging. Out of 900 patients, 74 had positron emission tomography/computed tomography. Multivariate analysis was performed by controlling positron emission tomography/computed tomography, Sodium Iodide I 131 scan, neck ultrasonography, age, sex, primary tumor size, stage, histology, thyroglobulin. Patients were grouped according to results of Sodium Iodide I 131 scan and positron emission tomography/computed tomography. Positron emission tomography/computed tomography was positive in 23 of 74 patients. The sensitivity for positron emission tomography was 11/11(100%), the specificity was 51/63 (81.0%), the positive predictive value was 11/23 (47.8%), and the negative predictive value was 51/51 (100%). The sensitivity for the neck ultrasonography was 4/8 (50%), the specificity was 53/60 (88.3%), positive predictive value was 4/11 (36.4%), and negative predictive value was 53/57 (93.0%). 50% of patients who had Sodium Iodide I 131 negative scan and positive positron emission tomography/computed tomography had a change in management. Thirty-six percent with positive neck ultrasonography had a change in management. Out of 11 recurrences, 6 had distant metastatic disease, and 5/11 had regional nodal disease. Neck ultrasonography showed nodal metastasis in 4/5 (80%). Positron emission tomography/computed tomography altered management in the presence of a high thyroglobulin level and a negative Sodium Iodide I 131 scan. Neck ultrasonography should be the first line of imaging with rising thyroglobulin levels. Positron emission tomography/computed tomography should be considered for cases with high thyroglobulin levels and normal neck ultrasonography to look for distant metastatic disease.

  4. Parathyroid hormone levels 1 hour after thyroidectomy: an early predictor of postoperative hypocalcemia

    PubMed Central

    AlQahtani, Awad; Parsyan, Armen; Payne, Richard; Tabah, Roger

    2014-01-01

    Background Parathyroid dysfunction leading to symptomatic hypocalcemia is not uncommon following a total or completion thyroidectomy and is often associated with significant patient morbidity and a prolonged hospital stay. A simple, reliable indicator to identify patients at risk would permit earlier pharmacologic prophylaxis to avoid these adverse outcomes. We examined the role of intact parathormone (PTH) levels 1 hour after surgery as a predictor of post-thyroidectomy hypocalcemia. Methods We prospectively reviewed the cases of consecutive patients undergoing total or completion thyroidectomy. Ionized calcium (Ca2+) and intact PTH levels were measured preoperatively and at 1-, 6- and 24-hour intervals postoperatively. The specificity, sensitivity, negative and positive predictive values of the 1-hour PTH serum levels (PTH-1) in predicting 24-hour post-thyroidectomy hypocalcemia and eucalcemia were determined. Results We reviewed the cases of 149 patients. Biochemical hypocalcaemia (Ca2+ < 1.1 mmol/L) developed in 38 of 149 (25.7%) patients 24 hours after thyroidectomy. The sensitivity, specificity, positive and negative predictive values of a low PTH-1 were 89%, 100%, 97% and 100%, respectively. Conclusion We found that PTH-1 levels were predictive of symptomatic hypocalcemia 24 hours after thyroidectomy. Routine use of this assay should be considered, as it could prompt the early administration of calcitriol in patients at risk of hypocalcemia and allow for the safe and timely discharge of patients expected to remain eucalcemic. PMID:25078927

  5. Parathyroid hormone levels 1 hour after thyroidectomy: an early predictor of postoperative hypocalcemia.

    PubMed

    AlQahtani, Awad; Parsyan, Armen; Payne, Richard; Tabah, Roger

    2014-08-01

    Parathyroid dysfunction leading to symptomatic hypocalcemia is not uncommon following a total or completion thyroidectomy and is often associated with significant patient morbidity and a prolonged hospital stay. A simple, reliable indicator to identify patients at risk would permit earlier pharmacologic prophylaxis to avoid these adverse outcomes. We examined the role of intact parathormone (PTH) levels 1 hour after surgery as a predictor of post-thyroidectomy hypocalcemia. We prospectively reviewed the cases of consecutive patients undergoing total or completion thyroidectomy. Ionized calcium (Ca(2+)) and intact PTH levels were measured preoperatively and at 1-, 6- and 24-hour intervals postoperatively. The specificity, sensitivity, negative and positive predictive values of the 1-hour PTH serum levels (PTH-1) in predicting 24-hour post-thyroidectomy hypocalcemia and eucalcemia were determined. We reviewed the cases of 149 patients. Biochemical hypocalcaemia (Ca(2+) < 1.1 mmol/L) developed in 38 of 149 (25.7%) patients 24 hours after thyroidectomy. The sensitivity, specificity, positive and negative predictive values of a low PTH-1 were 89%, 100%, 97% and 100%, respectively. We found that PTH-1 levels were predictive of symptomatic hypocalcemia 24 hours after thyroidectomy. Routine use of this assay should be considered, as it could prompt the early administration of calcitriol in patients at risk of hypocalcemia and allow for the safe and timely discharge of patients expected to remain eucalcemic.

  6. Role of ascitic fluid adenosine deaminase (ADA) and serum CA-125 in the diagnosis of tuberculous peritonitis.

    PubMed

    Ali, N; Nath, N C; Parvin, R; Rahman, A; Bhuiyan, T M; Rahman, M; Mohsin M N

    2014-12-01

    This cross sectional study was carried out in the department of gastroenterology, BIRDEM, Dhaka from January 2010 to May 2011 to determine the role of ascitic fluid ADA and serum CA-125 in the diagnosis of clinically suspected tubercular peritonitis. Total 30 patients (age 39.69 ± 21.26, 18M/12F) with clinical suspicion of tuberculosis peritonitis were included in this study after analyzing selection criteria. Laparoscopic peritoneal biopsy with 'histopathological diagnosis' was considered gold standard against which accuracics of two biomarkers (ADA & CA-125) were compared. Cut off value of ADA and CA-125 are 24 u/l, 35 U/ml respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ADA as a diagnostic modality in tuberculos peritonitis were 87.5%, 83.33%, 95.45%, 62.5% and 86.67% respectively where as CA-125 was found to have 83.33% sensitivity, 50% specificity, 86.9% positive predictive value, 42.85% negative predictive value and 76.6% accuracy. Both biomarkers are simple, non-invasive, rapid and relatively cheap diagnostic test where as laparoscopy is an invasive procedure, costly & requires trained staff and not without risk and also not feasible in all the centre in our country. So ascitic fluid ADA and serum CA-125 are important diagnostic test for peritoneal tuberculosis.

  7. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy?

    PubMed

    Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi

    2017-02-01

    Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.

  8. Tracheal aspirate Gram stain has limited sensitivity and specificity for detecting Staphylococcus aureus.

    PubMed

    Tetenta, Sodienye; Metersky, Mark L

    2011-01-01

    The increasing incidence of respiratory infections due to methicillin resistant Staphylococcus aureus has resulted in increased empirical use of antibiotics active against this pathogen. There are limited data available as to whether the Gram stain of respiratory tract secretions accurately predicts growth of S. aureus. We theorized that the distinctive morphology of S. aureus would allow rapid, accurate identification of the organism in respiratory secretions. The authors reviewed all available Gram stains of tracheal aspirates sent to our hospital's microbiology laboratory between 1 April 2008 and 31 October 2008, while blinded to the culture result, and recorded the presence or absence of organisms with a morphology consistent with S. aureus. These results were correlated with the semiquantitative culture result. Among 136 tracheal aspirates studied, 50 (37%) grew S. aureus. The Gram stain was read as positive for organisms consistent with S. aureus in 34 of these. Among 86 samples that did not grow S. aureus, the Gram stain was read as negative in 62. Therefore, the Gram stain had a sensitivity of 68%, a specificity of 72%, a negative predictive value of 80% and a positive predictive value of 59% for culture of S. aureus. False negative Gram stains were more likely when the culture revealed only rare or small growth of S. aureus (P = 0.01). In this study, the tracheal aspirate Gram stain read by an experienced clinician who was not a microbiologist, was not accurate enough to reliably predict the growth of S. aureus. © 2010 The Authors. Respirology © 2010 Asian Pacific Society of Respirology.

  9. [The Clinical Application of Video Mediastinoscopy and CT in the N Staging of Preoperative Lung Cancer.].

    PubMed

    Wang, Zhiheng; Qi, Weibo; Zhu, Yong; Lin, Ruobai

    2009-10-20

    Preoperative lung cancer with mediastinal lymph nodes metastasis can be diagnosed by vedio mediastinoscopy (VM) and CT. This study was to explore the value of VM and CT in the diagnosis of N staging of preoperative lung cancer, and to discuss the difference between the two methods. Forty-eight cases diagnosed of lung cancer by CT or PET-CT were examined by VM. The sensitivity, specificity, validity, positive predictive value and negative predictive value of VM and CT were speculated according to the postoperative pathological reports, and the difference between VM and CT in the diagnosis of lung cancer with mediastinal lymph nodes metastasis was discussed. (1)Under the examination of VM, 31 patients with the negative outcome received the direct operation; 14 patients with N2 received 2 courses of neoadjuvant chemotherapy before operation; 3 patients with N3 received chemotherapy and/or radiotherapy. (2)Forty-one cases with final diagnosis of lung cancer were used as samples to speculate the sensitivity, specificity, validity, positive predictive value and negative predictive value of VM. They were 93.3%, 100%, 97.6%, 100%, 96.3%, which of CT were 66.7%, 53.8%, 58.5%, 45.5%, 73.7% (Chi-square=4.083, P=0.039), the difference between VM and CT was statistically significant. (3)In this group, the complications of VM incidence rate was 2.08% (1/48), and the case was pneumothorax. VM is superior to CT in the diagnosis of N staging of preoperative lung cancer; Due to its safety and effectiveness, VM will be wildly used in the field of thoracic surgery.

  10. Asymptomatic bacteriuria in pregnant women attending Boo-Ali Hospital Tehran Iran: Urine analysis vs. urine culture.

    PubMed

    Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana

    2017-11-01

    Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture.

  11. Sensitivity and specificity of a CAD solution for lung nodule detection on chest radiograph with CTA correlation.

    PubMed

    Moore, William; Ripton-Snyder, Jennifer; Wu, George; Hendler, Craig

    2011-06-01

    The objective of this research was to determine the sensitivity and specificity of a commercially available computer-aided detection (CAD) system for detection of lung nodule on posterior-anterior (PA) chest radiograph in a varied patient population who are referred to computed tomographic angiogram (CTA) of the chest as a reference standard. Patients who had a PA chest radiograph with concomitant CTA of the chest were included in this retrospective study. The PA chest radiograph was analyzed by a CAD device, and results were recorded. A qualitative assessment of the CAD results was performed using a 5-point Likert scale. The CTA was then reviewed to determine if there were correlative nodules. The presence of a correlative nodule between 0.5 cm and 1.5 cm was considered a positive result. The baseline sensitivity of the system was determined to be 0.707 (95% CI = 0.52-0.86), with a specificity of 0.50 (95% CI = 0.38-0.76). Positive predictive value was 0.30 (95% CI = 0.24-0.49), with a negative predictive value of 0.858 (95% CI = 0.82-0.95), and accuracy of 0.555 (95% CI = 0.40-0.66). When excluding nodules that were qualitatively determined by a thoracic radiologist to be false positives, the specificity was 0.781 (95% CI = 0.764-0.839), the positive predictive value was 0.564 (95% CI = 0.491-0.654), the negative predictive value was 0.829 (95% CI = 0.819-0.878), and the accuracy was 0.737 (95% CI = 0.721-0.801). The use of CAD for lung nodule detection on chest radiograph, when used in conjunction with an experienced radiologist, has a very good sensitivity, specificity, and accuracy.

  12. Application of Recursive Partitioning to Derive and Validate a Claims-Based Algorithm for Identifying Keratinocyte Carcinoma (Nonmelanoma Skin Cancer).

    PubMed

    Chan, An-Wen; Fung, Kinwah; Tran, Jennifer M; Kitchen, Jessica; Austin, Peter C; Weinstock, Martin A; Rochon, Paula A

    2016-10-01

    Keratinocyte carcinoma (nonmelanoma skin cancer) accounts for substantial burden in terms of high incidence and health care costs but is excluded by most cancer registries in North America. Administrative health insurance claims databases offer an opportunity to identify these cancers using diagnosis and procedural codes submitted for reimbursement purposes. To apply recursive partitioning to derive and validate a claims-based algorithm for identifying keratinocyte carcinoma with high sensitivity and specificity. Retrospective study using population-based administrative databases linked to 602 371 pathology episodes from a community laboratory for adults residing in Ontario, Canada, from January 1, 1992, to December 31, 2009. The final analysis was completed in January 2016. We used recursive partitioning (classification trees) to derive an algorithm based on health insurance claims. The performance of the derived algorithm was compared with 5 prespecified algorithms and validated using an independent academic hospital clinic data set of 2082 patients seen in May and June 2011. Sensitivity, specificity, positive predictive value, and negative predictive value using the histopathological diagnosis as the criterion standard. We aimed to achieve maximal specificity, while maintaining greater than 80% sensitivity. Among 602 371 pathology episodes, 131 562 (21.8%) had a diagnosis of keratinocyte carcinoma. Our final derived algorithm outperformed the 5 simple prespecified algorithms and performed well in both community and hospital data sets in terms of sensitivity (82.6% and 84.9%, respectively), specificity (93.0% and 99.0%, respectively), positive predictive value (76.7% and 69.2%, respectively), and negative predictive value (95.0% and 99.6%, respectively). Algorithm performance did not vary substantially during the 18-year period. This algorithm offers a reliable mechanism for ascertaining keratinocyte carcinoma for epidemiological research in the absence of cancer registry data. Our findings also demonstrate the value of recursive partitioning in deriving valid claims-based algorithms.

  13. Low maternal sensitivity at 6 months of age predicts higher BMI in 48 month old girls but not boys.

    PubMed

    Wendland, Barbara E; Atkinson, Leslie; Steiner, Meir; Fleming, Alison S; Pencharz, Paul; Moss, Ellen; Gaudreau, Hélène; Silveira, Patricia P; Arenovich, Tamara; Matthews, Stephen G; Meaney, Michael J; Levitan, Robert D

    2014-11-01

    Large population-based studies suggest that systematic measures of maternal sensitivity predict later risk for overweight and obesity. More work is needed to establish the developmental timing and potential moderators of this association. The current study examined the association between maternal sensitivity at 6 months of age and BMI z score measures at 48 months of age, and whether sex moderated this association. Longitudinal Canadian cohort of children from birth (the MAVAN project). This analysis was based on a dataset of 223 children (115 boys, 108 girls) who had structured assessments of maternal sensitivity at 6 months of age and 48-month BMI data available. Mother-child interactions were videotaped and systematically scored using the Maternal Behaviour Q-Sort (MBQS)-25 items, a standardized measure of maternal sensitivity. Linear mixed-effects models and logistic regression examined whether MBQS scores at 6 months predicted BMI at 48 months, controlling for other covariates. After controlling for weight-relevant covariates, there was a significant sex by MBQS interaction (P=0.015) in predicting 48 month BMI z. Further analysis revealed a strong negative association between MBQS scores and BMI in girls (P=0.01) but not boys (P=0.72). Logistic regression confirmed that in girls only, low maternal sensitivity was associated with the higher BMI categories as defined by the WHO (i.e. "at risk for overweight" or above). A significant association between low maternal sensitivity at 6 months of age and high body mass indices was found in girls but not boys at 48 months of age. These data suggest for the first time that the link between low maternal sensitivity and early BMI z may differ between boys and girls. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Retrospective validation of the laparoscopic ICG SLN mapping in patients with grade 3 endometrial cancer.

    PubMed

    Papadia, Andrea; Gasparri, Maria Luisa; Radan, Anda P; Stämpfli, Chantal A L; Rau, Tilman T; Mueller, Michael D

    2018-04-24

    To evaluate the sensitivity, negative predictive value (NPV) and false-negative (FN) rate of the near infrared (NIR) indocyanine green (ICG) sentinel lymph node (SLN) mapping in patients with poorly differentiated endometrial cancer who have undergone a full pelvic and para-aortic lymphadenectomy after SLN mapping. We performed a retrospective analysis of patients with endometrial cancer undergoing a laparoscopic NIR-ICG SLN mapping followed by a systematic pelvic and para-aortic lymphadenectomy. Inclusion criteria were a grade 3 endometrial cancer or a high-risk histology (papillary serous, clear cell carcinoma, carcinosarcoma, and neuroendocrine carcinoma) and a completion pelvic and para-aortic lymphadenectomy to the renal vessels after SLN mapping. Overall and bilateral detection rates, sensitivity, NPV, and FN rates were calculated. From December 2012 until January 2017, 42 patients fulfilled inclusion criteria. Overall and bilateral detection rates were 100 and 90.5%, respectively. Overall, 23.8% of the patients had lymph node metastases. In one patient, despite negative bilateral pelvic SLNs, a metastatic non-SLN-isolated para-aortic metastasis was detected. This NSLN was clinically suspicious and sent to frozen section analysis during the surgery. FN rate, sensitivity, and NPV were 10, 90, and 97.1%, respectively. For the SLN mapping algorithm, FN rate, sensitivity, and NPV were 0, 100, and 100%, respectively. Laparoscopic NIR-ICG SLN mapping in high-risk endometrial cancer patients has acceptable sensitivity, FN rate, and NPV.

  15. CA19-9 serum levels predict micrometastases in patients with gastric cancer

    PubMed Central

    Potrc, Stojan; Mis, Katarina; Plankl, Mojca; Mars, Tomaz

    2016-01-01

    Abstract Background We explored the prognostic value of the up-regulated carbohydrate antigen (CA19-9) in node-negative patients with gastric cancer as a surrogate marker for micrometastases. Patients and methods Micrometastases were determined using reverse transcription quantitative polymerase chain reaction (RT-qPCR) for a subgroup of 30 node-negative patients. This group was used to determine the cut-off for preoperative CA19-9 serum levels as a surrogate marker for micrometastases. Then 187 node-negative T1 to T4 patients were selected to validate the predictive value of this CA19-9 threshold. Results Patients with micrometastases had significantly higher preoperative CA19-9 serum levels compared to patients without micrometastases (p = 0.046). CA19-9 serum levels were significantly correlated with tumour site, tumour diameter, and perineural invasion. Although not reaching significance, subgroup analysis showed better five-year survival rates for patients with CA19-9 serum levels below the threshold, compared to patients with CA19-9 serum levels above the cut-off. The cumulative survival for T2 to T4 node-negative patients was significantly better with CA19-9 serum levels below the cut-off (p = 0.04). Conclusions Preoperative CA19-9 serum levels can be used to predict higher risk for haematogenous spread and micrometastases in node-negative patients. However, CA19-9 serum levels lack the necessary sensitivity and specificity to reliably predict micrometastases. PMID:27247553

  16. Ability among adolescents for the metabolic syndrome to predict elevations in factors associated with type 2 diabetes and cardiovascular disease: data from the national health and nutrition examination survey 1999-2006.

    PubMed

    DeBoer, Mark D; Gurka, Matthew J

    2010-08-01

    The aim of this study was to compare currently proposed sets of pediatric metabolic syndrome criteria for the ability to predict elevations in "surrogate" factors that are associated with metabolic syndrome and with future cardiovascular disease and type 2 diabetes mellitus. These surrogate factors were fasting insulin, hemoglobin A1c (HbA1c), high-sensitivity C-reactive protein (hsCRP), and uric acid. Waist circumference (WC), blood pressure, triglycerides, high-density lipoprotein cholesterol (HDL-C), fasting glucose, fasting insulin, HbA1c, hsCRP, and uric acid measurements were obtained from 2,624 adolescent (12-18 years old) participants of the 1999-2006 National Health and Nutrition Examination Surveys. We identified children with metabolic syndrome as defined by six commonly used sets of pediatric metabolic syndrome criteria. We then defined elevations in the surrogate factors as values in the top 5% for the cohort and calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for each set of metabolic syndrome criteria and for each surrogate factor. Current pediatric metabolic syndrome criteria exhibited variable sensitivity and specificity for surrogate predictions. Metabolic syndrome criteria had the highest sensitivity for predicting fasting insulin (40-70%), followed by uric acid (31-54%), hsCRP (13-31%), and HbA1c (7-21%). The criteria of de Ferranti (which includes children with WC >75(th) percentile, compared to all other sets including children with WC >90(th) percentile) exhibited the highest sensitivity for predicting each of the surrogates, with only modest decrease in specificity compared to the other sets of criteria. However, the de Ferranti criteria also exhibited the lowest PPV values. Conversely, the pediatric International Diabetes Federation criteria exhibited the lowest sensitivity and the highest specificity. Pediatric metabolic syndrome criteria exhibit moderate sensitivity for detecting elevations in surrogate factors associated with metabolic syndrome and with risk for future disease. Inclusion of children with more modestly elevated WC improved sensitivity.

  17. IL-8 predicts pediatric oncology patients with febrile neutropenia at low risk for bacteremia.

    PubMed

    Cost, Carrye R; Stegner, Martha M; Leonard, David; Leavey, Patrick

    2013-04-01

    Despite a low bacteremia rate, pediatric oncology patients are frequently admitted for febrile neutropenia. A pediatric risk prediction model with high sensitivity to identify patients at low risk for bacteremia is not available. We performed a single-institution prospective cohort study of pediatric oncology patients with febrile neutropenia to create a risk prediction model using clinical factors, respiratory viral infection, and cytokine expression. Pediatric oncology patients with febrile neutropenia were enrolled between March 30, 2010 and April 1, 2011 and managed per institutional protocol. Blood samples for C-reactive protein and cytokine expression and nasopharyngeal swabs for respiratory viral testing were obtained. Medical records were reviewed for clinical data. Statistical analysis utilized mixed multiple logistic regression modeling. During the 12-month period, 195 febrile neutropenia episodes were enrolled. There were 24 (12%) episodes of bacteremia. Univariate analysis revealed several factors predictive for bacteremia, and interleukin (IL)-8 was the most predictive variable in the multivariate stepwise logistic regression. Low serum IL-8 predicted patients at low risk for bacteremia with a sensitivity of 0.9 and negative predictive value of 0.98. IL-8 is a highly sensitive predictor for patients at low risk for bacteremia. IL-8 should be utilized in a multi-institution prospective trial to assign risk stratification to pediatric patients admitted with febrile neutropenia.

  18. The link between hypomania risk and creativity: The role of heightened behavioral activation system (BAS) sensitivity.

    PubMed

    Kim, Bin-Na; Kwon, Seok-Man

    2017-06-01

    The relationship between bipolar disorder (BD) and creativity is well-known; however, relatively little is known about its potential mechanism. We investigated whether heightened behavioral activation system (BAS) sensitivity may mediate such relationship. Korean young adults (N=543) completed self-report questionnaires that included the Hypomanic Personality Scale (HPS), the Behavioral Activation System(BAS) Scale, the Everyday Creativity Scale (ECS), the Positive Affect and Negative Affect Schedule (PANAS), and the Altman Self-Rating Mania Scale (ASRM). Correlational, hierarchical regression and mediation analyses using bootstrap confidence intervals were conducted. As predicted, BAS sensitivity was associated with self-reported creativity as well as hypomania risk and symptoms. Even when positive affect was controlled, BAS sensitivity predicted incrementally significant variance in explaining creativity. In mediation analysis, BAS sensitivity partially mediated the relation between hypomania risk and creativity. Reliance on self-report measures in assessing creativity and usage of non-clinical sample. BAS sensitivity was related not only to mood pathology but also to creativity. As a basic affective temperament, BAS sensitivity may help explain incompatible sides of adaptation associated with BD. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Developing a clinical utility framework to evaluate prediction models in radiogenomics

    NASA Astrophysics Data System (ADS)

    Wu, Yirong; Liu, Jie; Munoz del Rio, Alejandro; Page, David C.; Alagoz, Oguzhan; Peissig, Peggy; Onitilo, Adedayo A.; Burnside, Elizabeth S.

    2015-03-01

    Combining imaging and genetic information to predict disease presence and behavior is being codified into an emerging discipline called "radiogenomics." Optimal evaluation methodologies for radiogenomics techniques have not been established. We aim to develop a clinical decision framework based on utility analysis to assess prediction models for breast cancer. Our data comes from a retrospective case-control study, collecting Gail model risk factors, genetic variants (single nucleotide polymorphisms-SNPs), and mammographic features in Breast Imaging Reporting and Data System (BI-RADS) lexicon. We first constructed three logistic regression models built on different sets of predictive features: (1) Gail, (2) Gail+SNP, and (3) Gail+SNP+BI-RADS. Then, we generated ROC curves for three models. After we assigned utility values for each category of findings (true negative, false positive, false negative and true positive), we pursued optimal operating points on ROC curves to achieve maximum expected utility (MEU) of breast cancer diagnosis. We used McNemar's test to compare the predictive performance of the three models. We found that SNPs and BI-RADS features augmented the baseline Gail model in terms of the area under ROC curve (AUC) and MEU. SNPs improved sensitivity of the Gail model (0.276 vs. 0.147) and reduced specificity (0.855 vs. 0.912). When additional mammographic features were added, sensitivity increased to 0.457 and specificity to 0.872. SNPs and mammographic features played a significant role in breast cancer risk estimation (p-value < 0.001). Our decision framework comprising utility analysis and McNemar's test provides a novel framework to evaluate prediction models in the realm of radiogenomics.

  20. Ovarian response to 150 µg corifollitropin alfa in a GnRH-antagonist multiple-dose protocol: a prospective cohort study.

    PubMed

    Lerman, Tamara; Depenbusch, Marion; Schultze-Mosgau, Askan; von Otte, Soeren; Scheinhardt, Markus; Koenig, Inke; Kamischke, Axel; Macek, Milan; Schwennicke, Arne; Segerer, Sabine; Griesinger, Georg

    2017-05-01

    The incidence of low (<6 oocytes) and high (>18 oocytes) ovarian response to 150 µg corifollitropin alfa in relation to anti-Müllerian hormone (AMH) and other biomarkers was studied in a multi-centre (n = 5), multi-national, prospective, investigator-initiated, observational cohort study. Infertile women (n = 212), body weight >60 kg, underwent controlled ovarian stimulation in a gonadotrophin-releasing hormone-antagonist multiple-dose protocol. Demographic, sonographic and endocrine parameters were prospectively assessed on cycle day 2 or 3 of a spontaneous menstruation before the administration of 150 µg corifollitropin alfa. Serum AMH showed the best correlation with the number of oocytes obtained among all predictor variables. In receiver-operating characteristic analysis, AMH at a threshold of 0.91 ng/ml showed a sensitivity of 82.4%, specificity of 82.4%, positive predictive value 52.9%and negative predictive value 95.1% for predicting low response (area under the curve [AUC], 95% CI; P-value: 0.853, 0.769-0.936; <0.0001). For predicting high response, the optimal threshold for AMH was 2.58 ng/ml, relating to a sensitivity of 80.0%, specificity 82.1%, positive predictive value 42.5% and negative predictive value 96.1% (AUC, 95% CI; P-value: 0.871, 0.787-0.955; <0.0001). In conclusion, patients with serum AMH concentrations between approximately 0.9 and 2.6 ng/ml were unlikely to show extremes of response. Copyright © 2017. Published by Elsevier Ltd.

  1. Validation of the cephalosporin intradermal skin test for predicting immediate hypersensitivity: a prospective study with drug challenge.

    PubMed

    Yoon, S-Y; Park, S Y; Kim, S; Lee, T; Lee, Y S; Kwon, H-S; Cho, Y S; Moon, H-B; Kim, T-B

    2013-07-01

    Cephalosporin is a major offending agent in terms of drug hypersensitivity along with penicillin. Cephalosporin intradermal skin tests (IDTs) have been widely used; however, their validity for predicting immediate hypersensitivity has not been studied. This study aimed to determine the predictive value of cephalosporin intradermal skin testing before administration of the drug. We prospectively conducted IDTs with four cephalosporins, one each of selected first-, second-, third-, or fourth-generation cephalosporins: ceftezol; cefotetan or cefamandole; ceftriaxone or cefotaxime; and flomoxef, respectively, as well as with penicillin G. After the skin test, whatever the result, one of the tested cephalosporins was administered intravenously and the patient was carefully observed. We recruited 1421 patients who required preoperative cephalosporins. Seventy-four patients (74/1421, 5.2%) were positive to at least one cephalosporin. However, none of responders had immediate hypersensitivity reactions after a challenge dose of the same or different cephalosporin, which were positive in the skin test. Four patients who suffered generalized urticaria and itching after challenge gave negative skin tests for the corresponding drug. The IDT for cephalosporin had a sensitivity of 0%, a specificity of 97.5%, a negative predictive value of 99.7%, and a positive predictive value (PPV) of 0%, when challenged with the same drugs that were positive in the skin test. Routine skin testing with a cephalosporin before its administration is not useful for predicting immediate hypersensitivity because of the extremely low sensitivity and PPV of the skin test (CRIS registration no. KCT0000455). © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. A Clinical Score to Predict Appendicitis in Older Male Children.

    PubMed

    Kharbanda, Anupam B; Monuteaux, Michael C; Bachur, Richard G; Dudley, Nanette C; Bajaj, Lalit; Stevenson, Michelle D; Macias, Charles G; Mittal, Manoj K; Bennett, Jonathan E; Sinclair, Kelly; Dayan, Peter S

    2017-04-01

    To develop a clinical score to predict appendicitis among older, male children who present to the emergency department with suspected appendicitis. Patients with suspected appendicitis were prospectively enrolled at 9 pediatric emergency departments. A total of 2625 patients enrolled; a subset of 961 male patients, age 8-18 were analyzed in this secondary analysis. Outcomes were determined using pathology, operative reports, and follow-up calls. Clinical and laboratory predictors with <10% missing data and kappa > 0.4 were entered into a multivariable model. Resultant β-coefficients were used to develop a clinical score. Test performance was assessed by calculating the sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratios. The mean age was 12.2 years; 49.9% (480) had appendicitis, 22.3% (107) had perforation, and the negative appendectomy rate was 3%. In patients with and without appendicitis, overall imaging rates were 68.6% (329) and 84.4% (406), respectively. Variables retained in the model included maximum tenderness in the right lower quadrant, pain with walking/coughing or hopping, and the absolute neutrophil count. A score ≥8.1 had a sensitivity of 25% (95% confidence interval [CI], 20%-29%), specificity of 98% (95% CI, 96%-99%), and positive predictive value of 93% (95% CI, 86%-97%) for ruling in appendicitis. We developed an accurate scoring system for predicting appendicitis in older boys. If validated, the score might allow clinicians to manage a proportion of male patients without diagnostic imaging. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  3. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    PubMed

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  4. Renal Complex Cystic Masses: Usefulness of Contrast-Enhanced Ultrasound (CEUS) in Their Assessment and Its Agreement with Computed Tomography.

    PubMed

    Sanz, Enrique; Hevia, Vital; Gómez, Victoria; Álvarez, Sara; Fabuel, Jose-Javier; Martínez, Laura; Rodriguez-Patrón, Rafael; González-Gordaliza, Cristina; Burgos, Francisco-Javier

    2016-12-01

    Around 10 % of renal cell carcinomas (RCC) are cystic, while some benign cysts have complex appearance in conventional diagnostic tests such as computed tomography (CT) or magnetic resonance imaging (MRI). These renal complex cystic masses (RCCMs) are a challenging entity in urological practice and sometimes have a difficult management, requiring surgical removal. Contrast-enhanced ultrasound (CEUS) is a very sensitive test detecting microvascularization in real time, and it has been used in the diagnostic workup of these kinds of lesions. The aim of our study was to assess the diagnostic power of CEUS in the evaluation of RCCM. This is a prospective observational study between April 2011 and July 2014. A total of 66 patients with 67 RCCMs were enrolled (Bosniak 2-4). Twenty-four patients underwent surgical removal of the RCCM. All participants underwent CEUS (experimental) and CT (control). All CEUS procedures were performed by a single high-experienced observer (urologist). Benign lesions were defined as those Bosniak 2-2F, and malignant were Bosniak 3-4. Statistical analysis was made measuring consistency (kappa index and Landis-Koch scale) and validity (sensitivity, specificity, positive and negative predictive values) of the study. Median size of RCCM measured by CEUS and CT was 3.8 cm (interquartile range (AIQ) 3.2-4.6) and 3.9 cm (AIQ 3.2-4.5), respectively. Kappa index shows good agreement between both tests (0.71; 95 % CI 0.57-0.85), both overall and stratified by categories according to Bosniak classification. CEUS has a sensitivity 100 %, specificity 81.4 %, positive predictive value 70.4 %, and negative predictive value 100 %. A total of eight RCCMs were discordant, and seven of eight classified as malignant by CEUS and not by CT. Of those seven lesions classified as malignant by CEUS, six (six of seven, 85.7 %) were malignant in the pathological exam. CEUS is a very useful tool for assessing RCCM, with good results in terms of consistency and validity. It has a good diagnostic power, with a sensitivity of 100 % and a negative predictive value of 100 %. Its main limitations are the experience required, a special software, and being observer-dependent.

  5. Presence of High-Risk HPV mRNA in Relation to Future High-Grade Lesions among High-Risk HPV DNA Positive Women with Minor Cytological Abnormalities

    PubMed Central

    Johansson, Hanna; Bjelkenkrantz, Kaj; Darlin, Lotten; Dilllner, Joakim; Forslund, Ola

    2015-01-01

    Objective Continuous expression of E6- and E7-oncogenes of high-risk human papillomavirus (HPV) types is necessary for the development and maintenance of the dysplastic phenotype. The aim of the study was to determine the sensitivity and specificity of the APTIMA HPV mRNA assay (Hologic) in predicting future development of high-grade cervical intraepithelial neoplasia (CIN) among high-risk HPV-DNA-positive women with atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous epithelial lesion (LSIL) cytology. Methods Archived SurePath cervical samples of women ≥ 35 years of age with high-risk HPV DNA-positive ASCUS (n = 211) or LSIL, (n = 131) were tested for the presence of high-risk HPV E6/E7 mRNA using the APTIMA HPV assay, and the women were monitored for development of histopathologically verified CIN2+. Results Twenty-nine percent (61/211) of the women in the ASCUS group, and 34.3% (45/131) in the LSIL group developed CIN2+ within 4.5 years of follow-up. The prevalence of HPV mRNA was 90.0% (95% CI 85.9-94.0) among women with ASCUS and 95.4% (95% CI 91.8-99.0) among women with LSIL. The presence of HPV E6/E7 mRNA was associated with future development of CIN2+ among women with ASCUS and LSIL (p=0.02). The mRNA assay demonstrated high sensitivity in predicting future CIN2+ and CIN3 for index ASCUS (96.7%; 95% CI 87.6-99.4 and 100%; 95% CI 82.2-100, respectively) and LSIL (97.8%, 95% CI 86.8-99.9 and 100%, 95% CI 79.9-100, respectively). The corresponding specificity was low, 12.7% (95% CI 7.9-19.3) and 5.8% (95% CI 2.2-13.6), for future CIN2+, respectively. The negative predictive value of the HPV mRNA assay for detecting future CIN3 was 100%, since no mRNA-negative woman developed CIN3 (0/27) as compared to 13.6% (43/315) of the mRNA-positive women (p = 0.03). Conclusion The APTIMA mRNA assay demonstrated high sensitivity but low specificity in predicting future CIN2+ among women with minor cytological abnormalities. The assay had high negative predictive value for future CIN3, indicating that HPV-mRNA-negative women are at low risk of progression to high grade CIN. PMID:25893988

  6. [The incidence of human papilloma virus associated vulvar cancer in younger women is increasing and wide local excision with sentinel lymph node biopsie has become standard].

    PubMed

    Fehr, Mathias K

    2011-10-01

    Sentinel lymph node (SLN) dissections have been shown to be sensitive for the evaluation of nodal basins for metastatic disease and are associated with decreased short-term and long-term morbidity when compared with complete lymph node dissection. There has been increasing interest in the use of SLN technology in gynecologic cancers. This review assesses the current evidence-based literature for the use of SLN dissections in gynecologic malignancies. Recent literature continues to support the safety and feasibility of SLN biopsy for early stage vulvar cancer with negative predictive value approaching 100 % and low false negative rates. Alternatively, for endometrial cancer most studies have reported low false-negative rates, with variable sensitivities and have reported low detection rates of the sentinel node. Studies examining the utility of SLN biopsy in early-stage cervical cancer remain promising with detection rates, sensitivities, and false-negative rates greater than 90 % for stage 1B1 tumors. SLN dissections have been shown to be effective and safe in certain, select vulvar cancer patients and can be considered an alternative surgical approach for these patients. For endometrial and cervical cancer, SLN dissection continues to have encouraging results and however needs further investigation.

  7. Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes

    PubMed Central

    Cho, Seon; Kim, Suyoung; Cho, Han-Ik

    2017-01-01

    Background Albuminuria is generally known as a sensitive marker of renal and cardiovascular dysfunction. It can be used to help predict the occurrence of nephropathy and cardiovascular disorders in diabetes. Individuals with prediabetes have a tendency to develop macrovascular and microvascular pathology, resulting in an increased risk of retinopathy, cardiovascular diseases, and chronic renal diseases. We evaluated the clinical value of a strip test for measuring the urinary albumin-to-creatinine ratio (ACR) in prediabetes and diabetes. Methods Spot urine samples were obtained from 226 prediabetic and 275 diabetic subjects during regular health checkups. Urinary ACR was measured by using strip and laboratory quantitative tests. Results The positive rates of albuminuria measured by using the ACR strip test were 15.5% (microalbuminuria, 14.6%; macroalbuminuria, 0.9%) and 30.5% (microalbuminuria, 25.1%; macroalbuminuria, 5.5%) in prediabetes and diabetes, respectively. In the prediabetic population, the sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of the ACR strip method were 92.0%, 94.0%, 65.7%, 99.0%, and 93.8%, respectively; the corresponding values in the diabetic population were 80.0%, 91.6%, 81.0%, 91.1%, and 88.0%, respectively. The median [interquartile range] ACR values in the strip tests for measurement ranges of <30, 30-300, and >300 mg/g were 9.4 [6.3-15.4], 46.9 [26.5-87.7], and 368.8 [296.2-575.2] mg/g, respectively, using the laboratory method. Conclusions The ACR strip test showed high sensitivity, specificity, and negative predictive value, suggesting that the test can be used to screen for albuminuria in cases of prediabetes and diabetes. PMID:27834062

  8. [Early prediction of the neurological result at 12 months in newborns at neurological risk].

    PubMed

    Herbón, F; Garibotti, G; Moguilevsky, J

    2015-08-01

    The aim of this study was to evaluate the Amiel-Tison neurological examination (AT) and cranial ultrasound at term for predicting the neurological result at 12 months in newborns with neurological risk. The study included 89 newborns with high risk of neurological damage, who were discharged from the Neonatal Intensive Care of the Hospital Zonal Bariloche, Argentina. The assessment consisted of a neurological examination and cranial ultrasound at term, and neurological examination and evaluation of development at 12 months. The sensitivity, specificity, positive and negative predictor value was calculated. The relationship between perinatal factors and neurodevelopment at 12 month of age was also calculated using logistic regression models. Seventy children completed the follow-up. At 12 months of age, 14% had an abnormal neurological examination, and 17% abnormal development. The neurological examination and the cranial ultrasound at term had low sensitivity to predict abnormal neurodevelopment. At 12 months, 93% of newborns with normal AT showed normal neurological results, and 86% normal development. Among newborns with normal cranial ultrasound the percentages were 90 and 81%, respectively. Among children with three or more perinatal risk factors, the frequency of abnormalities in the neurological response was 5.4 times higher than among those with fewer risk factors, and abnormal development was 3.5 times more frequent. The neurological examination and cranial ultrasound at term had low sensitivity but high negative predictive value for the neurodevelopment at 12 months. Three or more perinatal risk factors were associated with neurodevelopment abnormalities at 12 months of age. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  9. Using the STOPBANG questionnaire and other pre-test probability tools to predict OSA in younger, thinner patients referred to a sleep medicine clinic.

    PubMed

    McMahon, Michael J; Sheikh, Karen L; Andrada, Teotimo F; Holley, Aaron B

    2017-12-01

    The STOPBANG questionnaire is used to predict the presence of obstructive sleep apnea (OSA). We sought to assess the performance of the STOPBANG questionnaire in younger, thinner patients referred to a sleep medicine clinic. We applied the STOPBANG questionnaire to patients referred for level I polysomnography (PSG) at our sleep center. We calculated likelihood ratios and area under the receiver operator characteristic (AUROC) curve and performed sensitivity analyses. We performed our analysis on 338 patients referred for PSG. Only 17.2% (n = 58) were above age 50 years, and 30.5 and 6.8% had a BMI above 30 and 35 years, respectively. The mean apnea-hypopnea index (AHI) was 12.9 ± 16.4 and 63.9% had an AHI ≥5. The STOPBANG (threshold ≥3) identified 83.1% of patients as high risk for an AHI ≥5, and sensitivity, specificity, positive (PPV), and negative predictive values (NPV) were 83.8, 18.0, 64.4, and 38.0%, respectively. Positive and negative likelihood ratios were poor at 1.02-1.11 and 0.55-0.90, respectively, across AHI thresholds (AHI ≥5, AHI ≥15 and AHI ≥30), and AUROCs were 0.52 (AHI ≥5) and 0.56 (AHI ≥15). Sensitivity analyses adjusting for insomnia, combat deployment, traumatic brain injury, post-traumatic stress disorder, clinically significant OSA (ESS >10 and/or co-morbid disease), and obesity did not significantly alter STOPBANG performance. In a younger, thinner population with predominantly mild-to-moderate OSA, the STOPBANG Score does not accurately predict the presence of obstructive sleep apnea.

  10. "Stops walking when talking" as a predictor of falls in people with stroke living in the community

    PubMed Central

    Hyndman, D; Ashburn, A

    2004-01-01

    Objective: To test "Stops walking when talking" (SWWT) as a predictor of falls among people with stroke living in the community. Methods: People with stroke were identified through hospital records. Mobility, ADL (activites of daily living) ability, mental state, mood, and SWWT were assessed in a single session. Participants were followed prospectively for six months, using falls diaries and regular telephone calls. Results: Sixty three participants (36 men, 27 women; mean (SD) age 68.4 (10.6)) were recruited. Four subjects had a brainstem lesion, 30 had right hemisphere, and 29 left hemisphere infarctions. Mean time since onset of stroke was 20 months (range 2–72). Twenty six subjects stopped walking when a conversation was started and 16 of them fell during the six month follow up period (11 experienced repeated falls). For all fallers (⩾1) the positive predictive value of SWWT was 62% (16/26), the negative predictive value 62% (23/37), specificity 70% (23/33) and sensitivity 53% (16/30). For repeat fallers (⩾2) the positive predictive value of SWWT was 42% (11/26), the negative predictive value 89% (33/37), specificity 69% (33/48) and sensitivity 73% (11/15). Those who stopped walking were significantly more disabled (p<0.001)—that is, they were more dependent in activities of daily living, had worse gross function as well as worse upper and lower limb function, and had depression (p = 0.012). Conclusions: The specificity of the SWWT test was lower but sensitivity was higher than previously reported. Although the SWWT test was easy to use, its clinical usefulness as a single indicator of fall risk in identifying those community dwelling people with stroke most at risk of falls and in need of therapeutic intervention is questionable. PMID:15201358

  11. Fingerprints of Sea Level Rise on Changing Tides in the Chesapeake and Delaware Bays

    NASA Astrophysics Data System (ADS)

    Ross, Andrew C.; Najjar, Raymond G.; Li, Ming; Lee, Serena Blyth; Zhang, Fan; Liu, Wei

    2017-10-01

    Secular tidal trends are present in many tide gauge records, but their causes are often unclear. This study examines trends in tides over the last century in the Chesapeake and Delaware Bays. Statistical models show negative M2 amplitude trends at the mouths of both bays, while some upstream locations have insignificant or positive trends. To determine whether sea level rise is responsible for these trends, we include a term for mean sea level in the statistical models and compare the results with predictions from numerical and analytical models. The observed and predicted sensitivities of M2 amplitude and phase to mean sea level are similar, although the numerical model amplitude is less sensitive to sea level. The sensitivity occurs as a result of strengthening and shifting of the amphidromic system in the Chesapeake Bay and decreasing frictional effects and increasing convergence in the Delaware Bay. After accounting for the effect of sea level, significant negative background M2 and S2 amplitude trends are present; these trends may be related to other factors such as dredging, tide gauge errors, or river discharge. Projected changes in tidal amplitudes due to sea level rise over the 21st century are substantial in some areas, but depend significantly on modeling assumptions.

  12. Clinical value of polymerase chain reaction in the diagnosis of joint tuberculosis by detecting the DNA of Mycobacterium tuberculosis.

    PubMed

    Sun, Yong-sheng; Lou, Si-quan; Wen, Jian-min; Lv, Wei-xin; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin

    2011-02-01

    To assess the clinical value of polymerase chain reaction (PCR) in the diagnosis and differential diagnosis of joint tuberculosis (TB). PCR was used blindly to detect the DNA of Mycobacterium tuberculosis (M.TB) in five specimens of M.TB, 5 of BCG, and 10 of other bacteria. Then, M. TB in 98 samples from patients with joint TB and 100 samples from patients with non-tubercular joint disorders were detected by PCR, acid-fast staining and culture,. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PCR were calculated. The χ2 test was used for statistical analysis of the frequency of various factors. At the same time, some problems with PCR were also systematically analyzed. (1) In the "standard samples", both M. TB and BCG showed positive while other bacteria were negative. (2) In 98 cases from patients with joint TB, 81 were positive by PCR, 6 by acid-fast staining, and 17 by culture. In 100 cases from patients with non-tuberculous joint disorders, 9 were positive by PCR, and none by either acid-fast staining or culture. Sensitivity, specificity, accuracy, positive and negative predictive value of PCR were 82.65% (81/98), 91.00% (91/100), 86.87% (172/198), 90.00% (81/90) and 84.26% (91/108), respectively. (3) The positive rates for PCR, acid-fast staining and culture in detection of M. TB were 82.65% (81/98), 6.12% (6/98), and 17.34% (17/98), respectively. There were statistically significant differences between the three methods (P < 0.001). (4) The process of PCR is automatic, and can be completed within 3 to 6 hours, whereas 4 to 8 weeks are required for the conventional culture of M. TB. PCR is a sensitive, specific, rapid, simple and minimally invasive method for detection of M. TB in samples from joint TB, and can play an important role in early and rapid diagnosis and differential diagnosis of joint TB. But it also has some limitations, such as false positivity and false negativity. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  13. The RIPASA score is sensitive and specific for the diagnosis of acute appendicitis in a western population.

    PubMed

    Malik, Muhammad Usman; Connelly, Tara M; Awan, Faisal; Pretorius, Frederik; Fiuza-Castineira, Constantino; El Faedy, Osama; Balfe, Paul

    2017-04-01

    The definitive diagnosis of acute appendicitis (AA) requires histopathological examination. Various clinical diagnostic scoring systems attempt to reduce negative appendectomy rates. The most commonly used in Western Europe and the USA is the Alvarado score. The Raja Isteri Pengiran Anak Saleha appendicitis (RIPASA) score achieves better sensitivity and specificity in Asian and Middle Eastern populations. We aimed to determine the diagnostic accuracy of the RIPASA score in Irish patients with AA. All patients who presented to our institution with right iliac fossa pain and clinically suspected AA between January 1 and December 31, 2015, were indentified from our hospital inpatient enquiry database and retrospectively studied. Operating theatre records and histology reports confirmed those who underwent a non-elective operative procedure and the presence or absence of AA. SPSS version 22 was used for statistical analysis. Standard deviation is provided where appropriate. Two hundred eight patients were included in the study (106/51% male, mean age 22.7 ± 9.2 years). One hundred thirty-five (64.9%) had histologically confirmed AA (mean symptom duration = 36.19 ± 15.90 h). At a score ≥7.5, the previously determined score most likely associated with AA in Eastern populations, the RIPASA scoring system demonstrated a sensitivity of 85.39%, specificity of 69.86%, positive predictive value of 84.06%, negative predictive value of 72.86% and diagnostic accuracy of 80% in our cohort. The RIPASA score is a useful tool to aid in the diagnosis of acute appendicitis in the Irish population. A score of ≥7.5 provides sensitivity and specificity exceeding that previously documented for the Alvarado score in Western populations. WHAT DOES THIS PAPER ADD TO THE LITERATURE?: This is the first study evaluating the utility of the RIPASA score in predicting acute appendicitis in a Western population. At a value of 7.5, a cut-off score suggestive of appendicitis in the Eastern population, RIPASA demonstrated a high-sensitivity, specificity, positive predictive value and diagnostic accuracy in our cohort and was more accurate than the commonly used Alvarado score.

  14. Determination of the diagnostic value of the Modified Mallampati Score, Upper Lip Bite Test and Facial Angle in predicting difficult intubation: A prospective descriptive study.

    PubMed

    Mahmoodpoor, Ata; Soleimanpour, Hassan; Golzari, Samad Ej; Nejabatian, Arezoo; Pourlak, Tannaz; Amani, Masoumeh; Hajmohammadi, Saeed; Hosseinzadeh, Hamzeh; Esfanjani, Robab Mehdizadeh

    2017-02-01

    Difficult intubation is a significant cause of mortality and morbidity related to anesthesia. We decided to evaluate the value of Modified Mallampati Score, Upper Lip Bite Test and Facial Angle in the prediction of difficult intubation. In a prospective descriptive study, data from 132 patients who were candidates for elective maxillofacial surgeries under general anesthesia were gathered. Facial Angles were measured by a maxillofacial surgeon according to cephalometry. The Modified Mallampati Score and Upper Lip Bite Test were first measured by an anesthesiologist and then another anesthesiologist was assigned to record the Cormack and Lehane score during the intubation. Grades 3 and 4 were considered as difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and Youden index were calculated for all tests. Difficult intubation was reported in 12% of the patients. Facial Angle≤82.5° can predict difficult intubation with 87.5% sensitivity and 88.8% specificity. Among the three tests, a high Modified Mallampati Score had the highest specificity (94.5%) and a high Modified Mallampati Score and Facial Angle (FA≤82.5°) had the highest sensitivity (87.5%). The highest NPV, sensitivity and Youden index were observed when using Facial Angle with the Modified Mallampati Score or with Upper Lip Bite Test. Facial Angle has a high sensitivity, NPV and Youden index for the prediction of difficult intubation, but the best result is achieved when Facial Angle is used in combination with either the Modified Mallampati Score or Upper Lip Bit Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Rapid antigen detection tests for malaria diagnosis in severely ill Papua New Guinean children: a comparative study using Bayesian latent class models.

    PubMed

    Manning, Laurens; Laman, Moses; Rosanas-Urgell, Anna; Turlach, Berwin; Aipit, Susan; Bona, Cathy; Warrell, Jonathan; Siba, Peter; Mueller, Ivo; Davis, Timothy M E

    2012-01-01

    Although rapid diagnostic tests (RDTs) have practical advantages over light microscopy (LM) and good sensitivity in severe falciparum malaria in Africa, their utility where severe non-falciparum malaria occurs is unknown. LM, RDTs and polymerase chain reaction (PCR)-based methods have limitations, and thus conventional comparative malaria diagnostic studies employ imperfect gold standards. We assessed whether, using Bayesian latent class models (LCMs) which do not require a reference method, RDTs could safely direct initial anti-infective therapy in severe ill children from an area of hyperendemic transmission of both Plasmodium falciparum and P. vivax. We studied 797 Papua New Guinean children hospitalized with well-characterized severe illness for whom LM, RDT and nested PCR (nPCR) results were available. For any severe malaria, the estimated prevalence was 47.5% with RDTs exhibiting similar sensitivity and negative predictive value (NPV) to nPCR (≥96.0%). LM was the least sensitive test (87.4%) and had the lowest NPV (89.7%), but had the highest specificity (99.1%) and positive predictive value (98.9%). For severe falciparum malaria (prevalence 42.9%), the findings were similar. For non-falciparum severe malaria (prevalence 6.9%), no test had the WHO-recommended sensitivity and specificity of >95% and >90%, respectively. RDTs were the least sensitive (69.6%) and had the lowest NPV (96.7%). RDTs appear a valuable point-of-care test that is at least equivalent to LM in diagnosing severe falciparum malaria in this epidemiologic situation. None of the tests had the required sensitivity/specificity for severe non-falciparum malaria but the number of false-negative RDTs in this group was small.

  16. Support Vector Machines to improve physiologic hot flash measures: application to the ambulatory setting.

    PubMed

    Thurston, Rebecca C; Hernandez, Javier; Del Rio, Jose M; De La Torre, Fernando

    2011-07-01

    Most midlife women have hot flashes. The conventional criterion (≥2 μmho rise/30 s) for classifying hot flashes physiologically has shown poor performance. We improved this performance in the laboratory with Support Vector Machines (SVMs), a pattern classification method. We aimed to compare conventional to SVM methods to classify hot flashes in the ambulatory setting. Thirty-one women with hot flashes underwent 24 h of ambulatory sternal skin conductance monitoring. Hot flashes were quantified with conventional (≥2 μmho/30 s) and SVM methods. Conventional methods had low sensitivity (sensitivity=.57, specificity=.98, positive predictive value (PPV)=.91, negative predictive value (NPV)=.90, F1=.60), with performance lower with higher body mass index (BMI). SVMs improved this performance (sensitivity=.87, specificity=.97, PPV=.90, NPV=.96, F1=.88) and reduced BMI variation. SVMs can improve ambulatory physiologic hot flash measures. Copyright © 2010 Society for Psychophysiological Research.

  17. Additional corpus biopsy enhances the detection of Helicobacter pylori infection in a background of gastritis with atrophy

    PubMed Central

    2012-01-01

    Background The best sites for biopsy-based tests to evaluate H. pylori infection in gastritis with atrophy are not well known. This study aimed to evaluate the site and sensitivity of biopsy-based tests in terms of degree of gastritis with atrophy. Methods One hundred and sixty-four (164) uninvestigated dyspepsia patients were enrolled. Biopsy-based tests (i.e., culture, histology Giemsa stain and rapid urease test) and non-invasive tests (anti-H. pylori IgG) were performed. The gold standard of H. pylori infection was defined according to previous criteria. The sensitivity, specificity, positive predictive rate and negative predictive rate of biopsy-based tests at the gastric antrum and body were calculated in terms of degree of gastritis with atrophy. Results The prevalence rate of H. pylori infection in the 164 patients was 63.4%. Gastritis with atrophy was significantly higher at the antrum than at the body (76% vs. 31%; p<0.001). The sensitivity of biopsy-based test decreased when the degree of gastritis with atrophy increased regardless of biopsy site (for normal, mild, moderate, and severe gastritis with atrophy, the sensitivity of histology Giemsa stain was 100%, 100%, 88%, and 66%, respectively, and 100%, 97%, 91%, and 66%, respectively, for rapid urease test). In moderate to severe antrum or body gastritis with atrophy, additional corpus biopsy resulted in increased sensitivity to 16.67% compare to single antrum biopsy. Conclusions In moderate to severe gastritis with atrophy, biopsy-based test should include the corpus for avoiding false negative results. PMID:23272897

  18. Identifying QT prolongation from ECG impressions using a general-purpose Natural Language Processor

    PubMed Central

    Denny, Joshua C.; Miller, Randolph A.; Waitman, Lemuel Russell; Arrieta, Mark; Peterson, Joshua F.

    2009-01-01

    Objective Typically detected via electrocardiograms (ECGs), QT interval prolongation is a known risk factor for sudden cardiac death. Since medications can promote or exacerbate the condition, detection of QT interval prolongation is important for clinical decision support. We investigated the accuracy of natural language processing (NLP) for identifying QT prolongation from cardiologist-generated, free-text ECG impressions compared to corrected QT (QTc) thresholds reported by ECG machines. Methods After integrating negation detection to a locally-developed natural language processor, the KnowledgeMap concept identifier, we evaluated NLP-based detection of QT prolongation compared to the calculated QTc on a set of 44,318 ECGs obtained from hospitalized patients. We also created a string query using regular expressions to identify QT prolongation. We calculated sensitivity and specificity of the methods using manual physician review of the cardiologist-generated reports as the gold standard. To investigate causes of “false positive” calculated QTc, we manually reviewed randomly selected ECGs with a long calculated QTc but no mention of QT prolongation. Separately, we validated the performance of the negation detection algorithm on 5,000 manually-categorized ECG phrases for any medical concept (not limited to QT prolongation) prior to developing the NLP query for QT prolongation. Results The NLP query for QT prolongation correctly identified 2,364 of 2,373 ECGs with QT prolongation with a sensitivity of 0.996 and a positive predictive value of 1.000. There were no false positives. The regular expression query had a sensitivity of 0.999 and positive predictive value of 0.982. In contrast, the positive predictive value of common QTc thresholds derived from ECG machines was 0.07–0.25 with corresponding sensitivities of 0.994–0.046. The negation detection algorithm had a recall of 0.973 and precision of 0.982 for 10,490 concepts found within ECG impressions. Conclusions NLP and regular expression queries of cardiologists’ ECG interpretations can more effectively identify QT prolongation than the automated QTc intervals reported by ECG machines. Future clinical decision support could employ NLP queries to detect QTc prolongation and other reported ECG abnormalities. PMID:18938105

  19. The accuracy of confrontation visual field test in comparison with automated perimetry.

    PubMed Central

    Johnson, L. N.; Baloh, F. G.

    1991-01-01

    The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764

  20. Predictive value of flat-panel CT for haemorrhagic transformations in patients with acute stroke treated with thrombectomy.

    PubMed

    Rouchaud, Aymeric; Pistocchi, Silvia; Blanc, Raphaël; Engrand, Nicolas; Bartolini, Bruno; Piotin, Michel

    2014-03-01

    Haemorrhagic transformations are pejorative for patients with acute ischaemic stroke (AIS). We estimated flat-panel CT performances to detect brain parenchymal hyperdense lesions immediately after mechanical thrombectomy directly on the angiography table in patients with AIS, and its ability to predict haemorrhagic transformation. We also evaluated an easy-reading protocol for post-procedure flat-panel CT evaluation by clinicians to enable them to determine the potential risk of haemorrhage. Two neuroradiologists retrospectively reviewed post-procedural flat-panel CT and 24 h follow-up imaging. We evaluated hyperdense lesions on flat-panel CT to predict the occurrence of haemorrhagic transformation within 24 h detected with conventional imaging. Of 63 patients, 60.3% presented post-procedural parenchymal hyperdensity and 54.0% had haemorrhagic transformation. Significantly more patients with hyperdense lesions on post-thrombectomy flat-panel CT presented haemorrhagic transformation (84.2% vs 8.0%; p<0.0001). No significant haemorrhagic transformations were detected for patients without parenchymal hyperdensity. Sensitivity and specificity of hyperdense lesions on flat-panel CT for the prediction of haemorrhagic transformation were 94.1% (80.3-99.3%) and 79.3% (60.3-92.0%), respectively. The positive and negative predictive values for the occurrence of haemorrhage were 84.2% (68.8-94.0%) and 92.0% (74.0-99.0%), respectively. For significant parenchymal haemorrhage type 2, sensitivity and negative predictive values were 100%. We observed good homogeneity between the different readers. Hyperdensity on post-procedural flat-panel CT was associated with a tendency for higher risk of death and lower risk of good clinical outcome. Flat-panel CT appears to be a good tool to detect brain parenchymal hyperdensities after mechanical thrombectomy in patients with AIS and to predict haemorrhagic transformation.

  1. [Determination of prognostic value of the OESIL risk score at 6 months in a Colombian cohort with syncope evaluated in the emergency department; first Latin American experience].

    PubMed

    Díaz-Tribaldos, Diana Carolina; Mora, Guillermo; Olaya, Alejandro; Marín, Jorge; Sierra Matamoros, Fabio

    2017-07-14

    To establish the prognostic value, with sensitivity, specificity, positive predictive value, and negative predictive value for the OESIL syncope risk score to predict the presentation of severe outcomes (death, invasive interventions, and readmission) after 6 months of observation in adults who consulted the emergency department due to syncope. Observational, prospective, and multicentre study with enrolment of subjects older than 18 years, who consulted in the emergency department due to syncope. A record was mad of the demographic and clinical information of all patients. The OESIL risk score was calculated, and severe patient outcomes were followed up during a 6 month period using telephone contact. A total of 161 patients met the inclusion criteria and were followed up for 6 months. A score above or equal to 2 in the risk score, classified as high risk, was present in 72% of the patients. The characteristics of the risk score to predict the combined outcome of mortality, invasive interventions, and readmission for a score above or equal to 2 were 75.7, 30.5, 43.1, and 64.4% for sensitivity, specificity, positive predictive value, and negative predictive value, respectively. A score above or equal to 2 in the OESIL risk score applied in Colombian population was of limited use to predict the studied severe outcomes. This score will be unable to discriminate between patients that benefit of early admission and further clinical studies. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  2. CURB-65 Performance Among Admitted and Discharged Emergency Department Patients With Community-acquired Pneumonia.

    PubMed

    Sharp, Adam L; Jones, Jason P; Wu, Ivan; Huynh, Dan; Kocher, Keith E; Shah, Nirav R; Gould, Michael K

    2016-04-01

    Pneumonia severity tools were primarily developed in cohorts of hospitalized patients, limiting their applicability to the emergency department (ED). We describe current community ED admission practices and examine the accuracy of the CURB-65 to predict 30-day mortality for patients, either discharged or admitted with community-acquired pneumonia (CAP). A retrospective, observational study of adult CAP encounters in 14 community EDs within an integrated healthcare system. We calculated CURB-65 scores for all encounters and described the use of hospitalization, stratified by each score (0-5). We then used each score as a cutoff to calculate sensitivity, specificity, positive predictive value, negative predictive value (NPV), positive likelihood ratios, and negative likelihood ratios for predicting 30-day mortality. The sample included 21,183 ED encounters for CAP (7,952 discharged and 13,231 admitted). The C-statistic describing the accuracy of CURB-65 for predicting 30-day mortality in the full sample was 0.761 (95% confidence interval [CI], 0.747-0.774). The C-statistic was 0.864 (95% CI, 0.821-0.906) among patients discharged from the ED compared with 0.689 (95% CI, 0.672-0.705) among patients who were admitted. Among all ED encounters a CURB-65 threshold of ≥1 was 92.8% sensitive and 38.0% specific for predicting mortality, with a 99.9% NPV. Among all encounters, 62.5% were admitted, including 36.2% of those at lowest risk (CURB-65 = 0). CURB-65 had very good accuracy for predicting 30-day mortality among patients discharged from the ED. This severity tool may help ED providers risk stratify patients to assist with disposition decisions and identify unwarranted variation in patient care. © 2016 by the Society for Academic Emergency Medicine.

  3. Prediction of occult lymph node metastasis in squamous cell carcinoma of the oral cavity and the oropharynx using peritumoral Prospero homeobox protein 1 lymphatic nuclear quantification.

    PubMed

    Mermod, Maxime; Bongiovanni, Massimo; Petrova, Tatiana V; Dubikovskaya, Elena A; Simon, Christian; Tolstonog, Genrich; Monnier, Yan

    2016-09-01

    The use of lymphatic vessel density as a predictor of occult lymph node metastasis (OLNM) in head and neck squamous cell carcinoma (HNSCC) has never been reported. Staining of the specific lymphatic endothelial cells nuclear marker, PROX1, as an indicator of lymphatic vessel density was determined by counting the number of positive cells in squamous cell carcinomas (SCCs) of the oral cavity and the oropharynx with clinically negative necks. Correlation with histopathological data was established. Peritumoral PROX1 lymphatic nuclear count significantly correlated with the detection of OLNM in multivariate analysis (p < .005). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of this parameter was 60%, 95%, 85%, and 90%, respectively. Peritumoral PROX1 lymphatic nuclear count in primary SCCs of the oral cavity and the oropharynx allows accurate prediction of occult lymph node metastasis. © 2016 Wiley Periodicals, Inc. Head Neck 38: 1407-1415, 2016. © 2016 Wiley Periodicals, Inc.

  4. An indigenously developed nitrite kit to aid in the diagnosis of urinary tract infection.

    PubMed

    Sood, S; Upadhyaya, P; Kapil, A; Lodha, R; Jain, Y; Bagga, A

    1999-09-01

    To evaluate the utility of an indigenously developed nitrite kit for the rapid diagnosis of urinary tract infection (UTI) METHODS: 1018 urine specimens were collected from all cases where there was clinical suspicion of UTI. Samples were cultured as per standard microbiological protocol. Presence of nitrites was indicated by the development of purple color on addition of color developing solution and compared with the set of graded positive and negative controls also provided in the Kit. The results of the nitrite kit were compared with the semi-quantitative urine culture as the gold standard. The sensitivity, specificity, positive predictive and negative predictive values were 47%, 87%, 31% and 93%, respectively. Nitrite kit as a screening test can decrease the work load in the clinical bacteriology laboratory. More importantly in a field set up that is devoid of culture facilities, it can be used to correctly predict the absence of UTI.

  5. Neither Single nor a Combination of Routine Laboratory Parameters can Discriminate between Gram-positive and Gram-negative Bacteremia

    PubMed Central

    Ratzinger, Franz; Dedeyan, Michel; Rammerstorfer, Matthias; Perkmann, Thomas; Burgmann, Heinz; Makristathis, Athanasios; Dorffner, Georg; Loetsch, Felix; Blacky, Alexander; Ramharter, Michael

    2015-01-01

    Adequate early empiric antibiotic therapy is pivotal for the outcome of patients with bloodstream infections. In clinical practice the use of surrogate laboratory parameters is frequently proposed to predict underlying bacterial pathogens; however there is no clear evidence for this assumption. In this study, we investigated the discriminatory capacity of predictive models consisting of routinely available laboratory parameters to predict the presence of Gram-positive or Gram-negative bacteremia. Major machine learning algorithms were screened for their capacity to maximize the area under the receiver operating characteristic curve (ROC-AUC) for discriminating between Gram-positive and Gram-negative cases. Data from 23,765 patients with clinically suspected bacteremia were screened and 1,180 bacteremic patients were included in the study. A relative predominance of Gram-negative bacteremia (54.0%), which was more pronounced in females (59.1%), was observed. The final model achieved 0.675 ROC-AUC resulting in 44.57% sensitivity and 79.75% specificity. Various parameters presented a significant difference between both genders. In gender-specific models, the discriminatory potency was slightly improved. The results of this study do not support the use of surrogate laboratory parameters for predicting classes of causative pathogens. In this patient cohort, gender-specific differences in various laboratory parameters were observed, indicating differences in the host response between genders. PMID:26522966

  6. Temperament Variation in Sensitivity to Parenting: Predicting Changes in Depression and Anxiety

    ERIC Educational Resources Information Center

    Kiff, Cara J.; Lengua, Liliana J.; Bush, Nicole R.

    2011-01-01

    Temperament was examined as a moderator of maternal parenting behaviors, including warmth, negativity, autonomy granting, and guidance. Observations of parenting and questionnaire measures of temperament and adjustment were obtained from a community sample (N = 214; ages 8-12). Trajectories of depression and anxiety were assessed across 3 years.…

  7. WASP (Write a Scientific Paper) using Excel - 11: Test characteristics.

    PubMed

    Grech, Victor

    2018-07-01

    The calculation of various test characteristics may be required as part of a data analysis exercise. This paper explains how to set up these calculations in Microsoft Excel in order to obtain sensitivity, specificity, positive and negative predictive values, diagnostic accuracy and prevalence. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Multi-Risk Infants: Predicting Attachment Security from Sociodemographic, Psychosocial, and Health Risk among African-American Preterm Infants

    ERIC Educational Resources Information Center

    Candelaria, Margo; Teti, Douglas M.; Black, Maureen M.

    2011-01-01

    Background: Ecological and transactional theories link child outcomes to accumulated risk. This study hypothesized that cumulative risk was negatively related to attachment, and that maternal sensitivity mediated linkages between risk and attachment. Methods: One hundred and twelve high-risk African-American premature infant-mother dyads…

  9. Performance of an HRP-2 Rapid Diagnostic Test in Nigerian Children Less Than 5 Years of Age

    PubMed Central

    Ajumobi, Olufemi; Sabitu, Kabir; Nguku, Patrick; Kwaga, Jacob; Ntadom, Godwin; Gitta, Sheba; Elizeus, Rutebemberwa; Oyibo, Wellington; Nsubuga, Peter; Maire, Mark; Poggensee, Gabriele

    2015-01-01

    The diagnostic performance of histidine-rich protein 2 (HRP-2)–based malaria rapid diagnostic test (RDT) was evaluated in a mesoendemic area for malaria, Kaduna, Nigeria. We compared RDT results with expert microscopy results of blood samples from 295 febrile children under 5 years. Overall, 11.9% (35/295) tested positive with RDT compared with 10.5% (31/295) by microscopy: sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100%, 98.5%, 88.6%, and 100%, respectively. The RDT sensitivity was not affected by transmission season, parasite density, and age. Specificity and positive PV decreased slightly during the high-transmission season (97.5% and 83.3%). The RDT test positivity rates in the low- and high-transmission seasons were 9.4% and 13.5%, respectively. Overall, the test performance of this RDT was satisfactory. The findings of a low proportion of RDT false positives, no invalid and no false-negative results should validate the performance of RDTs in this context. PMID:25711608

  10. Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer

    PubMed Central

    Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges

    2017-01-01

    The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436

  11. Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study.

    PubMed

    Yang, Xiuzhen; Sun, Liying; Ye, Jingjing; Li, Xiaoying; Tao, Ran

    2017-12-01

    In this study we investigated the sonographic features of vaginal foreign bodies in girls and the diagnostic role of combined transperineal and transabdominal ultrasonography in the detection of vaginal foreign bodies in this population. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: A retrospective review of the records of 249 girls seen in the outpatient pediatric and adolescent gynecology clinic of our hospital and referred to our department for sonographic evaluation of suspected vaginal foreign bodies between 2013 and 2016 was performed. All patients were transperineally and transabdominally scanned using an ultrasound machine with 3-MHz and 7.5-MHz transducers. The sonographic features of the detected foreign bodies were recorded and reported. All patients also underwent pelvic radiography. The presence of foreign bodies was confirmed using vaginoscopy. Two hundred forty-nine patients were included in this study, and vaginal foreign bodies were detected in 181 patients. Vaginal foreign bodies often present in girls aged from 2 to 12 years old. The most common vaginal foreign bodies were toilet paper, beads, small parts of toys, cap of water color brush, and crayons. The overall sensitivity, specificity, positive and negative predictive values of transperineal/transabdominal sonography in the diagnosis of vaginal foreign bodies were 81%, 53%, 82%, and 51%, respectively. The sensitivity, specificity, and positive and negative predictive values of transabdominal sonography were 33%, 49%, 63%, and 21%, respectively. The sensitivity, specificity, and positive and negative predictive values of transperineal sonography were 64%, 49%, 77%, and 33%, respectively. Abnormal findings were detected using x-ray in only 43 of the 181 cases (23.7%). The sensitivity, specificity, and positive and negative predictive values of x-ray were 24%, 91%, 88%, and 31%, respectively. The size of the foreign bodies ranged from 2 mm to 35 mm. For foreign bodies larger than 5 mm, the rate of sonographic accuracy reached 100%. For foreign bodies smaller than 5 mm, 32 false positive results, and 34 false negative results were identified. One hundred thirty-nine of 181 foreign bodies were less than 2 cm from the vaginal orifice (77%). All foreign bodies were hyperechoic compared with adjacent tissues. Some vaginal foreign bodies had characteristic echo patterns. With the exception of 1 patient with a detained AAA battery that caused vaginal ulceration, the other patients had a full recovery. Vaginal foreign bodies were hyperechoic compared with adjacent tissues and often had characteristic echo patterns. The use of combined transperineal and transabdominal ultrasonography might be helpful in diagnosing foreign bodies, especially when the size of the foreign body is larger than 5 mm. Therefore, ultrasonography might be preferred for the initial evaluation of suspected vaginal foreign bodies, because it is a noninvasive, radiation-free, and inexpensive technique. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  12. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    PubMed

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  13. What is the role of florine-18 fluorodeoxyglucose/positron emission tomography/computed tomography imaging in well-differentiated thyroid cancers with negative iodine-131 scan high thyroglobulin and normal anti-thyroglobulin levels.

    PubMed

    Döner, Rana Kaya; Sager, Sait; Görtan, Fatma Arzu; Topuz, Özge Vural; Akyel, Reşit; Vatankulu, Betül; Baran, Ahmet; Teksoz, Serkan; Sönmezoglu, Kerim

    2016-01-01

    This retrospective study aims to assess the cut-off value of thyroglobulin (Tg) levels in nux or metastatic well-differentiated thyroid cancers (DTCs) with normal anti-Tg levels using with fluorodeoxyglucose/positron emission tomography/computed tomography (FDG PET/CT). We reviewed FDG PET/CT images of 104 patients with well DTC (28 men, 76 women) whose: Iodine-131 (131 I) whole-body scanning was negative but had elevated Tg with normal anti-Tg levels. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of florine-18-FDG PET/CT findings were found to be 95.92%, 87.27%, 87.04%, 96.00%, and 91.35%, respectively. The best Tg cut-off value was found to be 10.4 ng/ml. In the Tg level <10.4 ng/ml group, the sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT were found to be 94.1%, 91.30%, 88.8%, 95.4%, and 92.5%, respectively. In the other group, which Tg level ≥10.4 ng/ml, sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT exams were found to be 96.8%, 84.3%, 86.1%, 96.4%, and 90.6%, respectively. FDG PET/CT imaging is a valuable imaging method in the evaluation of patients with elevated serum Tg levels and normal anti-Tg levels. Furthermore, it has potential utility in the dedifferentiation of active foci that are present, and in assessing optimal decision making during follow-up.

  14. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    PubMed

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  15. Subjective global assessment of nutritional status in children.

    PubMed

    Mahdavi, Aida Malek; Ostadrahimi, Alireza; Safaiyan, Abdolrasool

    2010-10-01

    This study was aimed to compare the subjective and objective nutritional assessments and to analyse the performance of subjective global assessment (SGA) of nutritional status in diagnosing undernutrition in paediatric patients. One hundred and forty children (aged 2-12 years) hospitalized consecutively in Tabriz Paediatric Hospital from June 2008 to August 2008 underwent subjective assessment using the SGA questionnaire and objective assessment, including anthropometric and biochemical measurements. Agreement between two assessment methods was analysed by the kappa (κ) statistic. Statistical indicators including (sensitivity, specificity, predictive values, error rates, accuracy, powers, likelihood ratios and odds ratio) between SGA and objective assessment method were determined. The overall prevalence of undernutrition according to the SGA (70.7%) was higher than that by objective assessment of nutritional status (48.5%). Agreement between the two evaluation methods was only fair to moderate (κ = 0.336, P < 0.001). The sensitivity, specificity, positive and negative predictive value of the SGA method for screening undernutrition in this population were 88.235%, 45.833%, 60.606% and 80.487%, respectively. Accuracy, positive and negative power of the SGA method were 66.428%, 56.074% and 41.25%, respectively. Likelihood ratio positive, likelihood ratio negative and odds ratio of the SGA method were 1.628, 0.256 and 6.359, respectively. Our findings indicated that in assessing nutritional status of children, there is not a good level of agreement between SGA and objective nutritional assessment. In addition, SGA is a highly sensitive tool for assessing nutritional status and could identify children at risk of developing undernutrition. © 2009 Blackwell Publishing Ltd.

  16. Does ultrasonography accurately diagnose acute cholecystitis? Improving diagnostic accuracy based on a review at a regional hospital

    PubMed Central

    Hwang, Hamish; Marsh, Ian; Doyle, Jason

    2014-01-01

    Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607

  17. Computer-oriented synthesis of wide-band non-uniform negative resistance amplifiers

    NASA Technical Reports Server (NTRS)

    Branner, G. R.; Chan, S.-P.

    1975-01-01

    This paper presents a synthesis procedure which provides design values for broad-band amplifiers using non-uniform negative resistance devices. Employing a weighted least squares optimization scheme, the technique, based on an extension of procedures for uniform negative resistance devices, is capable of providing designs for a variety of matching network topologies. It also provides, for the first time, quantitative results for predicting the effects of parameter element variations on overall amplifier performance. The technique is also unique in that it employs exact partial derivatives for optimization and sensitivity computation. In comparison with conventional procedures, significantly improved broad-band designs are shown to result.

  18. Comparison of BD GeneOhm Methicillin-Resistant Staphylococcus aureus (MRSA) PCR versus the CHROMagar MRSA Assay for Screening Patients for the Presence of MRSA Strains▿

    PubMed Central

    Boyce, John M.; Havill, Nancy L.

    2008-01-01

    We compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay with the CHROMagar MRSA assay for the detection of MRSA in 286 nasal surveillance specimens. Compared with the CHROMagar MRSA assay, PCR had sensitivity, specificity, positive predictive value, and negative predictive values of 100%, 98.6%, 95.8%, and 100%, respectively. The mean PCR turnaround time was 14.5 h. PMID:18032616

  19. The Johns Hopkins Fall Risk Assessment Tool: A Study of Reliability and Validity.

    PubMed

    Poe, Stephanie S; Dawson, Patricia B; Cvach, Maria; Burnett, Margaret; Kumble, Sowmya; Lewis, Maureen; Thompson, Carol B; Hill, Elizabeth E

    Patient falls and fall-related injury remain a safety concern. The Johns Hopkins Fall Risk Assessment Tool (JHFRAT) was developed to facilitate early detection of risk for anticipated physiologic falls in adult inpatients. Psychometric properties in acute care settings have not yet been fully established; this study sought to fill that gap. Results indicate that the JHFRAT is reliable, with high sensitivity and negative predictive validity. Specificity and positive predictive validity were lower than expected.

  20. Comparative Study of GeneXpert with ZN Stain and Culture in Samples of Suspected Pulmonary Tuberculosis

    PubMed Central

    Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana

    2016-01-01

    Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212

  1. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    PubMed

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Reinforcement sensitivity theory and alcohol outcome expectancies in early adolescence.

    PubMed

    Lopez-Vergara, Hector I; Colder, Craig R; Hawk, Larry W; Wieczorek, William F; Eiden, Rina D; Lengua, Liliana J; Read, Jennifer P

    2012-03-01

    Little research has examined the development of alcohol expectancies in childhood, a notable omission as expectancies are viable targets for prevention programs. Moreover, limited alcohol expectancies research has been conducted from the perspective of psychobiological models of motivation despite the strong conceptual links between such models and cognitive models of alcohol use. To examine if the associations between individual differences from the revised reinforcement sensitivity theory (Gray JA, McNaughton N. The Neuropsychology of Anxiety: An Enquiry into the Functions of the Septo-hippocampal System (2nd ed.). Oxford, UK: Oxford University Press, 2000) and alcohol use is mediated by alcohol expectancies in a large community sample of early adolescents using a prospective design. 378 families (1 caregiver; 1 child) were recruited via random digit phone call using a prospective design. Our findings suggest that both a strong behavioral approach system and fight-flight or freeze system were associated with high levels of positive outcome expectancies, which subsequently predicted an increase in likelihood of alcohol use. There was also some evidence that drive (an aspect of behavioral approach system) was also positively associated with negative expectancies, which subsequently predicted a low probability of alcohol use. Individual differences in reinforcement sensitivity may influence the acquisition of positive and negative outcome expectancies, thereby potentially influencing the likelihood of alcohol use in early adolescence. Thus, reinforcement sensitivity theory is a promising theory to account for the link between neural models of addiction and early acquisition of alcohol use in humans.

  3. Accuracy and effectiveness of ultrasound-guided core-needle biopsy in the diagnosis of focal lesions in the salivary glands.

    PubMed

    Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio

    2018-01-31

    To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.

  4. Negative differential conductance and super-Poissonian shot noise in single-molecule magnet junctions

    PubMed Central

    Xue, Hai-Bin; Liang, Jiu-Qing; Liu, Wu-Ming

    2015-01-01

    Molecular spintroinic device based on a single-molecule magnet is one of the ultimate goals of semiconductor nanofabrication technologies. It is thus necessary to understand the electron transport properties of a single-molecule magnet junction. Here we study the negative differential conductance and super-Poissonian shot noise properties of electron transport through a single-molecule magnet weakly coupled to two electrodes with either one or both of them being ferromagnetic. We predict that the negative differential conductance and super-Poissonian shot noise, which can be tuned by a gate voltage, depend sensitively on the spin polarization of the source and drain electrodes. In particular, the shot noise in the negative differential conductance region can be enhanced or decreased originating from the different formation mechanisms of negative differential conductance. The effective competition between fast and slow transport channels is responsible for the observed negative differential conductance and super-Poissonian shot noise. In addition, we further discuss the skewness and kurtosis properties of transport current in the super-Poissonian shot noise regions. Our findings suggest a tunable negative differential conductance molecular device, and the predicted properties of high-order current cumulants are very interesting for a better understanding of electron transport through single-molecule magnet junctions. PMID:25736094

  5. Negative differential conductance and super-Poissonian shot noise in single-molecule magnet junctions.

    PubMed

    Xue, Hai-Bin; Liang, Jiu-Qing; Liu, Wu-Ming

    2015-03-04

    Molecular spintroinic device based on a single-molecule magnet is one of the ultimate goals of semiconductor nanofabrication technologies. It is thus necessary to understand the electron transport properties of a single-molecule magnet junction. Here we study the negative differential conductance and super-Poissonian shot noise properties of electron transport through a single-molecule magnet weakly coupled to two electrodes with either one or both of them being ferromagnetic. We predict that the negative differential conductance and super-Poissonian shot noise, which can be tuned by a gate voltage, depend sensitively on the spin polarization of the source and drain electrodes. In particular, the shot noise in the negative differential conductance region can be enhanced or decreased originating from the different formation mechanisms of negative differential conductance. The effective competition between fast and slow transport channels is responsible for the observed negative differential conductance and super-Poissonian shot noise. In addition, we further discuss the skewness and kurtosis properties of transport current in the super-Poissonian shot noise regions. Our findings suggest a tunable negative differential conductance molecular device, and the predicted properties of high-order current cumulants are very interesting for a better understanding of electron transport through single-molecule magnet junctions.

  6. Feature genes predicting the FLT3/ITD mutation in acute myeloid leukemia

    PubMed Central

    LI, CHENGLONG; ZHU, BIAO; CHEN, JIAO; HUANG, XIAOBING

    2016-01-01

    In the present study, gene expression profiles of acute myeloid leukemia (AML) samples were analyzed to identify feature genes with the capacity to predict the mutation status of FLT3/ITD. Two machine learning models, namely the support vector machine (SVM) and random forest (RF) methods, were used for classification. Four datasets were downloaded from the European Bioinformatics Institute, two of which (containing 371 samples, including 281 FLT3/ITD mutation-negative and 90 mutation-positive samples) were randomly defined as the training group, while the other two datasets (containing 488 samples, including 350 FLT3/ITD mutation-negative and 138 mutation-positive samples) were defined as the test group. Differentially expressed genes (DEGs) were identified by significance analysis of the micro-array data by using the training samples. The classification efficiency of the SCM and RF methods was evaluated using the following parameters: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and the area under the receiver operating characteristic curve. Functional enrichment analysis was performed for the feature genes with DAVID. A total of 585 DEGs were identified in the training group, of which 580 were upregulated and five were downregulated. The classification accuracy rates of the two methods for the training group, the test group and the combined group using the 585 feature genes were >90%. For the SVM and RF methods, the rates of correct determination, specificity and PPV were >90%, while the sensitivity and NPV were >80%. The SVM method produced a slightly better classification effect than the RF method. A total of 13 biological pathways were overrepresented by the feature genes, mainly involving energy metabolism, chromatin organization and translation. The feature genes identified in the present study may be used to predict the mutation status of FLT3/ITD in patients with AML. PMID:27177049

  7. Feature genes predicting the FLT3/ITD mutation in acute myeloid leukemia.

    PubMed

    Li, Chenglong; Zhu, Biao; Chen, Jiao; Huang, Xiaobing

    2016-07-01

    In the present study, gene expression profiles of acute myeloid leukemia (AML) samples were analyzed to identify feature genes with the capacity to predict the mutation status of FLT3/ITD. Two machine learning models, namely the support vector machine (SVM) and random forest (RF) methods, were used for classification. Four datasets were downloaded from the European Bioinformatics Institute, two of which (containing 371 samples, including 281 FLT3/ITD mutation-negative and 90 mutation‑positive samples) were randomly defined as the training group, while the other two datasets (containing 488 samples, including 350 FLT3/ITD mutation-negative and 138 mutation-positive samples) were defined as the test group. Differentially expressed genes (DEGs) were identified by significance analysis of the microarray data by using the training samples. The classification efficiency of the SCM and RF methods was evaluated using the following parameters: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and the area under the receiver operating characteristic curve. Functional enrichment analysis was performed for the feature genes with DAVID. A total of 585 DEGs were identified in the training group, of which 580 were upregulated and five were downregulated. The classification accuracy rates of the two methods for the training group, the test group and the combined group using the 585 feature genes were >90%. For the SVM and RF methods, the rates of correct determination, specificity and PPV were >90%, while the sensitivity and NPV were >80%. The SVM method produced a slightly better classification effect than the RF method. A total of 13 biological pathways were overrepresented by the feature genes, mainly involving energy metabolism, chromatin organization and translation. The feature genes identified in the present study may be used to predict the mutation status of FLT3/ITD in patients with AML.

  8. Arthroscopic and magnetic resonance imaging evaluation of meniscus lesions in the chronic anterior cruciate ligament-deficient knee.

    PubMed

    Naranje, Sameer; Mittal, Ravi; Nag, Hiralal; Sharma, Raju

    2008-09-01

    We performed this prospective study to evaluate the incidence of meniscus tears arthroscopically and the effectiveness of magnetic resonance imaging (MRI) in detecting these lesions in patients with chronic anterior cruciate ligament (ACL)-deficient knees. We reviewed 50 patients (46 male and 4 female) with a mean age of 27 years (range, 18 to 48 years) who underwent ACL reconstruction for chronic ACL tears. Injuries were classified as chronic because arthroscopy was performed after more than 6 weeks of injury. All 50 patients had clinical and MRI evaluation followed by knee arthroscopy. The MRI and arthroscopic findings were then analyzed by a single independent reviewer. The presence of meniscus tears and their morphologic types and locations were analyzed. The sensitivity, specificity, positive predictive value, and negative predictive value of MRI were calculated. On arthroscopy, a medial meniscus tear was found in 18 patients (36%), a lateral meniscus tear was found in 11 patients (22%), both menisci were torn in 8 patients (16%), and no meniscus lesion was found in 13 patients (26%). The most common morphologic type of tear seen in the medial meniscus was "complex" (n = 11 [42%]), and that in the lateral meniscus was "longitudinal" (n = 10 [53%]). The posterior horn of the meniscus was the most common tear site. The overall sensitivity, specificity, positive predictive value, and negative predictive value for detecting meniscus tears in chronic ACL-deficient knees on MRI were 90%, 89%, 87%, 93%, respectively. We conclude from our study that in chronic ACL-deficient patients, the prevalence of posterior horn medial meniscus tears seems to be high. Anterior horn tears and radial and horizontal patterns of meniscus tears seem to be rare in chronic ACL deficiency. MRI correlates well with arthroscopy and has high negative predictive values. Level I, prognostic prospective study.

  9. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    PubMed

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  10. Human papillomavirus DNA testing as an adjunct to cytology in cervical screening programs.

    PubMed

    Lörincz, Attila T; Richart, Ralph M

    2003-08-01

    Our objective was to review current large studies of human papillomavirus (HPV) DNA testing as an adjunct to the Papanicolaou test for cervical cancer screening programs. We analyzed 10 large screening studies that used the Hybrid Capture 2 test and 3 studies that used the polymerase chain reaction test in a manner that enabled reliable estimates of accuracy for detecting or predicting high-grade cervical intraepithelial neoplasia (CIN). Most studies allowed comparison of HPV DNA and Papanicolaou testing and estimates of the performance of Papanicolaou and HPV DNA as combined tests. The studies were selected on the basis of a sufficient number of cases of high-grade CIN and cancer to provide meaningful statistical values. Investigators had to demonstrate the ability to generate reasonably reliable Hybrid Capture 2 or polymerase chain reaction data that were either minimally biased by nature of study design or that permitted analytical techniques for addressing issues of study bias to be applied. Studies had to provide data for the calculation of test sensitivity, specificity, predictive values, odds ratios, relative risks, confidence intervals, and other relevant measures. Final data were abstracted directly from published articles or estimated from descriptive statistics presented in the articles. In some studies, new analyses were performed from raw data supplied by the principal investigators. We concluded that HPV DNA testing was a more sensitive indicator for prevalent high-grade CIN than either conventional or liquid cytology. A combination of HPV DNA and Papanicolaou testing had almost 100% sensitivity and negative predictive value. The specificity of the combined tests was slightly lower than the specificity of the Papanicolaou test alone, but this decrease could potentially be offset by greater protection from neoplastic progression and cost savings available from extended screening intervals. One "double-negative" HPV DNA and Papanicolaou test indicated better prognostic assurance against risk of future CIN 3 than 3 subsequent negative conventional Papanicolaou tests and may safely allow 3-year screening intervals for such low-risk women.

  11. Audit of paired anal cytology and histopathology outcomes in patients referred to a public sexual health clinic.

    PubMed

    Williams, Vincent M; Metcalf, Cecily; French, Martyn A; McCloskey, Jenny C

    2010-09-01

    The level of agreement between anal cytology and histopathology is not clear with only a few studies evaluating the reliability of anal specimen reporting. Australian data in relation to this are limited. The results of paired anal cytology and histopathology specimens received between 2002 and 2008 from patients who were referred within the sexual health clinic were retrieved from the anatomical pathology database. A total of 248 paired samples from 154 (21 females, 133 males) participants were extracted. Concurrent high risk human papilloma virus (hrHPV) DNA assay and HIV status for the study group were also collected. Data were tabulated according to reported grade of squamous abnormality based on the Bethesda system. Using the biopsy result as the gold standard the specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) for cytology were calculated and the association between grade of abnormality, HIV status and hrHPV infection estimated. Concordance between cytology and histology showed that in 204 (85%) paired samples both tests were categorised as abnormal (Kappa statistic 0.73, P = 0.013). The cytology result showed a sensitivity of 96%, specificity 14%, PPV 89% and NPV 31% when compared with histopathology. HrHPV assay was positive in 192 (80%) samples. High-grade squamous abnormalities were reported in biopsy specimens from 60% (n = 42/67) of HIV-positive subjects and 25% (n = 22/87) of HIV-negative subjects. HIV-positive individuals were more likely to be hrHPV positive, odds ratio (OR) 6.21 [95% confidence interval (CI) 2.69 to 14.34], when compared with HIV-negative subjects. Anal cytology is highly sensitive for the detection of abnormal squamous cells. While cytology has low specificity for predicting the grade of abnormality compared with biopsy outcome, its application as a screening method in asymptomatic at risk populations warrants further study.

  12. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    PubMed

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Feasibility and predictive performance of the Hendrich Fall Risk Model II in a rehabilitation department: a prospective study.

    PubMed

    Campanini, Isabella; Mastrangelo, Stefano; Bargellini, Annalisa; Bassoli, Agnese; Bosi, Gabriele; Lombardi, Francesco; Tolomelli, Stefano; Lusuardi, Mirco; Merlo, Andrea

    2018-01-11

    Falls are a common adverse event in both elderly inpatients and patients admitted to rehabilitation units. The Hendrich Fall Risk Model II (HIIFRM) has been already tested in all hospital wards with high fall rates, with the exception of the rehabilitation setting. This study's aim is to address the feasibility and predictive performances of HIIFRM in a hospital rehabilitation department. A 6 months prospective study in a Italian rehabilitation department with patients from orthopaedic, pulmonary, and neurological rehabilitation wards. All admitted patients were enrolled and assessed within 24 h of admission by means of the HIIFRM. The occurrence of falls was checked and recorded daily. HIIFRM feasibility was assessed as the percentage of successful administrations at admission. HIIFRM predictive performance was determined in terms of area under the Receiver Operating Characteristic (ROC) curve (AUC), best cutoff, sensitivity, specificity, positive and negative predictive values, along with their asymptotic 95% confidence intervals (95% CI). One hundred ninety-one patents were admitted. HIIFRM was feasible in 147 cases (77%), 11 of which suffered a fall (7.5%). Failures in administration were mainly due to bedridden patients (e.g. minimally conscious state, vegetative state). AUC was 0.779(0.685-0.873). The original HIIFRM cutoff of 5 led to a sensitivity of 100% with a mere specificity of 49%(40-57%), thus suggesting using higher cutoffs. Moreover, the median score for non-fallers at rehabilitation units was higher than that reported in literature for geriatric non fallers. The best trade-off between sensitivity and specificity was obtained by using a cutoff of 8. This lead to sensitivity = 73%(46-99%), specificity = 72%(65-80%), positive predictive value = 17% and negative predictive value = 97%. These results support the use of the HIIFRM as a predictive tool. The HIIFRM showed satisfactory feasibility and predictive performances in rehabilitation wards. Based on both available literature and these results, the prediction of falls among all hospital wards, with high risk of falling, could be achieved by means of a unique tool and two different cutoffs: a standard cutoff of 5 in geriatric wards and an adjusted higher cutoff in rehabilitation units, with predictive performances similar to those of the best-preforming pathology specific tools for fall-risk assessment.

  14. Rapid detection and ruling out of neonatal sepsis by PCR coupled with Electrospray Ionization Mass Spectrometry (PCR/ESI-MS).

    PubMed

    Delcò, Cristina; Karam, Oliver; Pfister, Riccardo; Gervaix, Alain; Renzi, Gesuele; Emonet, Stéphane; Schrenzel, Jacques; Posfay-Barbe, Klara M

    2017-05-01

    Sepsis is an important cause of morbidity and mortality in neonates and clinicians are typically required to administer empiric antibiotics while waiting for blood culture results. However, prolonged and inappropriate use of antibiotics is associated with various complications and adverse events. Better tools to rapidly rule out bacterial infections are therefore needed. We aimed to assess the negative predictive value of PCR coupled with Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) compared to conventional blood cultures in neonatal sepsis. Prospective observational study. All consecutive neonates (<28days old) with clinical suspicion of sepsis. Samples for PCR/ESI-MS analysis were collected at the same time as samples for the blood culture, before the initiation of antibiotics. Our primary objective was to evaluate the negative predictive value of PCR/ESI-MS for the detection of bacteria in the bloodstream of newborns with suspected sepsis. Our secondary objective was the evaluation of the sensitivity, specificity and positive predictive value of the PCR/ESI-MS in such a neonatal population. We analysed 114 samples over 14months. The median age and weight were 32weeks+3days and 1840g, respectively. Two patients had negative PCR/ESI-MS results, but positive blood cultures. Overall, the negative predictive value was 98% (95%CI: 92% to 100%). Based on these results, PCR/ESI-MS analysis of blood samples of neonates with suspected sepsis appears to have a very good negative predictive value when compared to blood cultures as gold standard. This novel test might allow for early reassessment of the need for antibiotics. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Interpretation of Negative Molecular Test Results in Patients With Suspected or Confirmed Ebola Virus Disease: Report of Two Cases.

    PubMed

    Edwards, Jeffrey K; Kleine, Christian; Munster, Vincent; Giuliani, Ruggero; Massaquoi, Moses; Sprecher, Armand; Chertow, Daniel S

    2015-12-01

    Quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is the most sensitive quantitative diagnostic assay for detection of Ebola virus in multiple body fluids. Despite the strengths of this assay, we present 2 cases of Ebola virus disease (EVD) and highlight the potential for false-negative results during the early and late stages of EVD. The first case emphasizes the low negative-predictive value of qRT-PCR during incubation and the early febrile stage of EVD, and the second case emphasizes the potential for false-negative results during recovery and late neurologic complications of EVD. Careful interpretation of test results are needed to guide difficult admission and discharge decisions in suspected or confirmed EVD.

  16. Prostate Specific Membrane Antigen Positron Emission Tomography May Improve the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging in Localized Prostate Cancer.

    PubMed

    Rhee, H; Thomas, P; Shepherd, B; Gustafson, S; Vela, I; Russell, P J; Nelson, C; Chung, E; Wood, G; Malone, G; Wood, S; Heathcote, P

    2016-10-01

    Positron emission tomography using ligands targeting prostate specific membrane antigen has recently been introduced. Positron emission tomography imaging with (68)Ga-PSMA-HBED-CC has been shown to detect metastatic prostate cancer lesions at a high rate. In this study we compare multiparametric magnetic resonance imaging and prostate specific membrane antigen positron emission tomography of the prostate with whole mount ex vivo prostate histopathology to determine the true sensitivity and specificity of these imaging modalities for detecting and locating tumor foci within the prostate. In a prospective clinical trial setting 20 patients with localized prostate cancer and a planned radical prostatectomy were recruited. All patients underwent multiparametric magnetic resonance imaging and positron emission tomography before surgery, and whole mount histopathology slides were directly compared to the images. European Society of Urogenital Radiology guidelines for reporting magnetic resonance imaging were used as a template for regional units of analysis. The uropathologist and radiologists were blinded to individual components of the study, and the final correlation was performed by visual and deformable registration analysis. A total of 50 clinically significant lesions were identified from the whole mount histopathological analysis. Based on regional analysis the sensitivity, specificity, positive predictive value and negative predictive value for multiparametric magnetic resonance imaging were 44%, 94%, 81% and 76%, respectively. With prostate specific membrane antigen positron emission tomography the sensitivity, specificity, positive predictive value and negative predictive value were 49%, 95%, 85% and 88%, respectively. Prostate specific membrane antigen positron emission tomography yielded a higher specificity and positive predictive value. A significant proportion of cancers are potentially missed and underestimated by both imaging modalities. Prostate specific membrane antigen positron emission tomography may be used in addition to multiparametric magnetic resonance imaging to help improve local staging in those patients undergoing retropubic radical prostatectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Tongue Blade Bite Test Predicts Mandible Fractures

    PubMed Central

    Neiner, John; Free, Rachael; Caldito, Gloria; Moore-Medlin, Tara; Nathan, Cherie-Ann

    2015-01-01

    The aim of the study is to evaluate the utility of a simple tongue blade bite test in predicting mandible fractures and use this test as an alternative screening tool for further workup. This is a retrospective chart review. An institutional review board approved the retrospective review of patients evaluated by the Department of Otolaryngology at a single institution for facial trauma performed from November 1, 2011, to February 27, 2014. Patients who had a bite test documented were included in the study. CT was performed in all cases and was used as the gold standard to diagnose mandible fractures. Variables analyzed included age, sex, fracture type/location on CT, bite test positivity, and operative intervention. A total of 86 patients met the inclusion criteria and of those 12 were pediatric patients. Majority of the patients were male (80.2%) and adult (86.0%; average age: 34.3 years). Fifty-seven patients had a negative bite test and on CT scans had no mandible fracture. Twenty-three patients had a positive bite test and a CT scan confirmed fracture. The bite test revealed a sensitivity of 88.5% (95% CI: 69.8–97.6%), specificity of 95.0% (95% CI:86.1–99%), positive predictive value [PPV] of 88.5% (95% CI: 69.8–97.6%), and negative predictive value [NPV] of 95.0% (95% CI: 86.1–99.0%). Among pediatric patients, the sensitivity was 100% (95% CI: 29.9–100%), specificity was 88.9% (95% CI: 68.4–100%), PPV was 75.0% (95% CI: 19.4–99.4%), and NPV was 100% (95% CI: 63.1–100%). The tongue blade bite test is a quick inexpensive diagnostic tool for the otolaryngologist with high sensitivity and specificity for predicting mandible fractures. In the pediatric population, where avoidance of unnecessary CT scans is of highest priority, a wider range of data collection should be undertaken to better assess its utility. PMID:27162567

  18. The malnutrition screening tool versus objective measures to detect malnutrition in hip fracture.

    PubMed

    Bell, J J; Bauer, J D; Capra, S

    2013-12-01

    The Malnutrition Screening Tool (MST) is the most commonly used screening tool in Australia. Poor screening tool sensitivity may lead to an under-diagnosis of malnutrition, with potential patient and economic ramifications. The present study aimed to determine whether the MST or anthropometric parameters adequately detect malnutrition in patients who were admitted to a hip fracture unit. Data were analysed for a prospective convenience sample (n = 100). MST screening was independently undertaken by nursing staff and a nutrition assistant. Mid upper arm circumference (MUAC) was measured by a trained nutrition assistant. Nutritional risk [MST score ≥ 2, body mass index (BMI) < 22 kg m(-2) , or MUAC < 25 cm] was compared with malnutrition diagnosed by accredited practicing dietitians using International Classification of Diseases version 10-Australian Modification (ICD10-AM) coding criteria. Malnutrition prevalence was 37.5% using ICD10-AM criteria. Delirium, dementia or preadmission cognitive impairment was present in 65% of patients. The BMI as a nutrition risk screen was the most valid predictor of malnutrition (sensitivity 75%; specificity 93%; positive predictive value 73%; negative predictive value 84%). Nursing MST screening was the least valid (sensitivity 73%; specificity 55%; positive predictive value 50%; negative predictive value 77%). There was only fair agreement between nursing and nutrition assistant screening using the MST (κ = 0.28). In this population with a high prevalence of delirium and dementia, further investigation is warranted into the performance of nutrition screening tools and anthropometric parameters such as BMI. All tools failed to predict a considerable number of patients with malnutrition. This may result in the under-diagnosis and treatment of malnutrition, leading to case-mix funding losses. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  19. Interleukin (IL)-1A and IL-6: Applications to the predictive diagnostic testing of radiation pneumonitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Yuhchyau; Hyrien, Ollivier; Williams, Jacqueline

    2005-05-01

    Purpose: To explore the application of interleukin (IL)-1{alpha} and IL-6 measurements in the predictive diagnostic testing for symptomatic radiation pneumonitis (RP). Methods and materials: In a prospective protocol investigating RP and cytokines, IL-1{alpha} and IL-6 values were analyzed by enzyme-linked immunosorbent assay from serial weekly blood samples of patients receiving chest radiation. We analyzed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) over selected threshold values for both cytokines in the application to diagnostic testing. Results: The average coefficient of variation was 51% of the weekly mean IL-1{alpha} level and 39% of the weekly mean IL-6 value.more » Interleukin 1{alpha} and IL-6 became positively correlated with time. Specificity for both cytokines was better than sensitivity. IL-6 globally outperformed IL-1{alpha} in predicting RP, with higher PPV and NPV. Conclusions: Our data demonstrate the feasibility of applying IL-1{alpha} and IL-6 measurements of blood specimens to predict RP. Interleukin-6 measurements offer stronger positive predictive value than IL-1{alpha}. This application might be further explored in a larger sample of patients.« less

  20. Buffering the negative effects of employee surface acting: the moderating role of employee-customer relationship strength and personalized services.

    PubMed

    Wang, Karyn L; Groth, Markus

    2014-03-01

    The impact of emotional labor on customer outcomes is gaining considerable attention in the literature, with research suggesting that the authenticity of emotional displays may positively impact customer outcomes. However, research investigating the impact of more inauthentic emotions on service delivery outcomes is mixed (see Chi, Grandey, Diamond, & Krimmel, 2011). This study explores 2 potential reasons for why the service outcomes of inauthentic emotions are largely inconsistent: the impact of distinct surface acting strategies and the role of service delivery context. Drawing on social-functional theories of emotions, we surveyed 243 dyads of employees and customers from a wide variety of services to examine the links between employee surface acting and customer service satisfaction, and whether this relationship is moderated by relationship strength and service personalization. Our findings suggest that faking positive emotions has no bearing on service satisfaction, but suppressing negative emotions interacts with contextual factors to predict customers' service satisfaction, in line with social-functional theories of emotions. Specifically, customers who know the employee well are less sensitive to the negative effects of suppressed negative emotions, and customers in highly personalized service encounters are more sensitive to the negative effects of suppressed negative emotions. We conclude with a discussion of theoretical and practical implications.

Top