Performance of the dipstick screening test as a predictor of negative urine culture
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
ABSTRACT Objective To investigate whether the urine dipstick screening test can be used to predict urine culture results. Methods A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. Results The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). Conclusion A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. PMID:28444086
Jabbar, Kausar J; Luthra, Rajalakshmi; Patel, Keyur P; Singh, Rajesh R; Goswami, Rashmi; Aldape, Ken D; Medeiros, L Jeffrey; Routbort, Mark J
2015-04-01
Mutation-specific antibodies for BRAF V600E and IDH1 R132H offer convenient immunohistochemical (IHC) assays to detect these mutations in tumors. Previous studies using these antibodies have shown high sensitivity and specificity, but use in routine diagnosis with qualitative assessment has not been well studied. In this retrospective study, we reviewed BRAF and IDH1 mutation-specific IHC results compared with separately obtained clinical next-generation sequencing results. For 67 tumors with combined IDH1 IHC and mutation data, IHC was unequivocally reported as positive or negative in all cases. Sensitivity of IHC for IDH1 R132H was 98% and specificity was 100% compared with mutation status. Four IHC-negative samples showed non-R132H IDH1 mutations including R132C, R132G, and P127T. For 128 tumors with combined BRAF IHC and mutation data, IHC was positive in 33, negative in 82, and equivocal in 13 tumors. The sensitivity of IHC was 97% and specificity was 99% when including only unequivocally positive or negative results. If equivocal IHC cases were included in the analysis as negative, sensitivity fell to 81%. If equivocal cases were classified as positive, specificity dropped to 91%. Eight IHC-negative samples showed non-V600E BRAF mutations including V600K, N581I, V600M, and K601E. We conclude that IHC for BRAF V600E and IDH1 R132H is relatively sensitive and specific, but there is a discordance rate that is not trivial. In addition, a significant proportion of patients harbor BRAF non-V600E or IDH1 non-R132H mutations not detectable by IHC, potentially limiting utility of IHC screening for BRAF and IDH1 mutations.
Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.
Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily
2015-01-01
The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.
Rahman, Muhammad Aziz; Spurrier, Nicola; Mahmood, Mohammad Afzal; Rahman, Mahmudur; Choudhury, Sohel Reza; Leeder, Stephen
2013-01-01
Aim/objectives The study aimed to validate the Rose Angina Questionnaire (RAQ) to detect coronary heart disease (CHD) by comparing with cardiologists' diagnoses in Bangladesh. Methods Patients aged 40–75 years attending to two cardiac hospitals were diagnosed as either CHD positive or CHD negative by cardiologists. The RAQ was used to reclassify them into CHD positive [RAQ] and CHD negative [RAQ]. Findings There were 302 CHD positive [cardiologists] and 302 CHD negative [cardiologists] individuals. The RAQ reclassified 194 individuals as CHD positive [RAQ] and 409 individuals as CHD negative [RAQ]. Therefore, the RAQ had 53% sensitivity and 89% specificity. There was no difference in sensitivity and specificity during subgroup analyzes by age and gender; the sensitivity was higher among people from lower socio-economic status. Conclusion The RAQ, having moderate sensitivity but high specificity to detect CHD, can be used to screen individuals at risk of CHD in large-scale epidemiological surveys. PMID:23438610
Jackson, Michael L; Rothman, Kenneth J
2015-03-10
The recently developed test-negative design is now standard for observational studies of influenza vaccine effectiveness (VE). It is unclear how influenza test misclassification biases test-negative VE estimates relative to VE estimates from traditional cohort or case-control studies. We simulated populations whose members may develop acute respiratory illness (ARI) due to influenza and to non-influenza pathogens. In these simulations, vaccination reduces the risk of influenza but not of non-influenza ARI. Influenza test sensitivity and specificity, risks of influenza and non-influenza ARI, and VE were varied across the simulations. In each simulation, we estimated influenza VE using a cohort design, a case-control design, and a test-negative design. In the absence of influenza test misclassification, all three designs accurately estimated influenza VE. In the presence of misclassification, all three designs underestimated VE. Bias in VE estimates was slightly greater in the test-negative design than in cohort or case-control designs. Assuming the use of highly sensitive and specific reverse-transcriptase polymerase chain reaction tests for influenza, bias in the test-negative studies was trivial across a wide range of realistic values for VE. Although influenza test misclassification causes more bias in test-negative studies than in traditional cohort or case-control studies, the difference is trivial for realistic combinations of attack rates, test sensitivity/specificity, and VE. Copyright © 2015 Elsevier Ltd. All rights reserved.
Detection of CIN by naked eye visualization after application of acetic acid.
Londhe, M; George, S S; Seshadri, L
1997-06-01
A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.
Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim
2014-01-01
There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049
Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-01-01
Background: Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. Objective: To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. Methods: SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. Results: A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357–4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. Conclusion: IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed. PMID:28583228
Ferastraoaru, Denisa; Shtessel, Maria; Lobell, Elizabeth; Hudes, Golda; Rosenstreich, David; de Vos, Gabriele
2017-06-01
Allergists commonly perform intradermal skin testing (IDST) after negative skin-prick testing (SPT) to comprehensively diagnose environmental allergic sensitization. However, with the availability of modern methods to detect serum-specific immunoglobulin E (ssIgE), it is unclear if ssIgE testing could substitute for IDST. To determine the efficacy of ssIgE testing and IDST when added to SPT in diagnosing environmental allergic sensitizations. SPT, IDST, and ssIgE testing to nine common environmental allergens were analyzed in 75 patients with oculonasal symptoms who presented to our allergy clinics in the Bronx, New York, between January 2014 and May 2015. A total of 651 SPT and 499 ssIgE tests were independently performed and revealed 162 (25%) and 127 (25%) sensitizations, respectively. When SPT results were negative, IDST results revealed 108 of 452 additional sensitizations (24%). In contrast, when SPT results were negative, ssIgE test results only revealed 9% additional sensitizations. When both SPT and IDST results were negative, ssIgE testing only detected 3% of additional sensitizations, and ssIgE levels were typically low in these cases (median, 1.25 kU/L; range, 0.357-4.47 kU/L). When both SPT and ssIgE test results were negative, IDST results detected 15% additional sensitizations. IDST detected more additional environmental sensitizations compared with ssIgE testing. IDST, therefore, may be useful when the SPT and/or ssIgE testing results were negative, but the exposure history indicated relevant allergic sensitization. Serology added only a little more information if both SPT and IDST results were negative but may be useful in combination with SPT if IDST cannot be performed.
Lau, Brian C; Collins, Michael W; Lovell, Mark R
2011-06-01
Concussions affect an estimated 136 000 high school athletes yearly. Computerized neurocognitive testing has been shown to be appropriately sensitive and specific in diagnosing concussions, but no studies have assessed its utility to predict length of recovery. Determining prognosis during subacute recovery after sports concussion will help clinicians more confidently address return-to-play and academic decisions. To quantify the prognostic ability of computerized neurocognitive testing in combination with symptoms during the subacute recovery phase from sports-related concussion. Cohort study (prognosis); Level of evidence, 2. In sum, 108 male high school football athletes completed a computer-based neurocognitive test battery within 2.23 days of injury and were followed until returned to play as set by international guidelines. Athletes were grouped into protracted recovery (>14 days; n = 50) or short-recovery (≤14 days; n = 58). Separate discriminant function analyses were performed using total symptom score on Post-Concussion Symptom Scale, symptom clusters (migraine, cognitive, sleep, neuropsychiatric), and Immediate Postconcussion Assessment and Cognitive Testing neurocognitive scores (verbal memory, visual memory, reaction time, processing speed). Multiple discriminant function analyses revealed that the combination of 4 symptom clusters and 4 neurocognitive composite scores had the highest sensitivity (65.22%), specificity (80.36%), positive predictive value (73.17%), and negative predictive value (73.80%) in predicting protracted recovery. Discriminant function analyses of total symptoms on the Post-Concussion Symptom Scale alone had a sensitivity of 40.81%; specificity, 79.31%; positive predictive value, 62.50%; and negative predictive value, 61.33%. The 4 symptom clusters alone discriminant function analyses had a sensitivity of 46.94%; specificity, 77.20%; positive predictive value, 63.90%; and negative predictive value, 62.86%. Discriminant function analyses of the 4 computerized neurocognitive scores alone had a sensitivity of 53.20%; specificity, 75.44%; positive predictive value, 64.10%; and negative predictive value, 66.15%. The use of computerized neurocognitive testing in conjunction with symptom clusters results improves sensitivity, specificity, positive predictive value, and negative predictive value of predicting protracted recovery compared with each used alone. There is also a net increase in sensitivity of 24.41% when using neurocognitive testing and symptom clusters together compared with using total symptoms on Post-Concussion Symptom Scale alone.
The utility of serum tryptase in the diagnosis of food-induced anaphylaxis.
Wongkaewpothong, Patcharaporn; Pacharn, Punchama; Sripramong, Chaweewan; Boonchoo, Siribangon; Piboonpocanun, Surapon; Visitsunthorn, Nualanong; Vichyanond, Pakit; Jirapongsananuruk, Orathai
2014-07-01
This study investigates the utility of serum tryptase for the confirmation of shrimp-induced anaphylaxis. Patients with a history of shrimp allergy and positive skin prick tests (SPT) to commercial shrimp extract were recruited for shrimp challenges. Serum total tryptase was obtained at baseline and 60 min (peak) after the onset of symptoms. Thirty-nine patients were challenged. There were 12 patients with anaphylaxis, 20 with mild reactions and 7 without symptoms (control group). Characteristic features and baseline tryptase were not different among the 3 groups. The peak tryptase levels were higher than the baseline in anaphylaxis and mild reaction groups (P<0.05). The delta-tryptase (peak minus baseline) and the tryptase ratio (peak divided by baseline) in the anaphylaxis group were higher than the mild reaction and control groups (P<0.01). The optimum cut-off for peak tryptase to confirm anaphylaxis was 2.99 µg/L with 50% sensitivity, 85% specificity, 3.33 positive likelihood ratio (LR) and 0.59 negative LR. The manufacturer's cut-off for peak tryptase was >11.4 µg/L with 17% sensitivity, 100% specificity, infinity positive LR and 0.83 negative LR. The best cut-off for delta-tryptase was ≥0.8 µg/L with 83% sensitivity, 93% specificity, 11.86 positive LR and 0.18 negative LR. The best cut-off for tryptase ratio was ≥1.5 with 92% sensitivity, 96% specificity, 23 positive LR and 0.08 negative LR. The peak tryptase level should be compared with the baseline value to confirm anaphylaxis. The tryptase ratio provide the best sensitivity, specificity, positive and negative LR than a single peak serum tryptase for the confirmation of shrimp-induced anaphylaxis.
Garcia, J J; Blanca, M; Moreno, F; Vega, J M; Mayorga, C; Fernandez, J; Juarez, C; Romano, A; de Ramon, E
1997-01-01
The quantitation of in vitro IgE antibodies to the benzylpenicilloyl determinant (BPO) is a useful tool for evaluating suspected penicillin allergic subjects. Although many different methods have been employed, few studies have compared their diagnostic specificity and sensitivity. In this study, the sensitivity and specificity of three different radio allergo sorbent test (RAST) methods for quantitating specific IgE antibodies to the BPO determinant were compared. Thirty positive control sera (serum samples from penicillin allergic subjects with a positive clinical history and a positive penicillin skin test) and 30 negative control sera (sera from subjects with no history of penicillin allergy and negative skin tests) were tested for BPO-specific IgE antibodies by RAST using three different conjugates coupled to the solid phase: benzylpenicillin conjugated to polylysine (BPO-PLL), benzylpenicillin conjugated to human serum albumin (BPO-HSA), and benzylpenicillin conjugated to an aminospacer (BPO-SP). Receiver operator control curves (ROC analysis) were carried out by determining different cut-off points between positive and negative values. Contingence tables were constructed and sensitivity, specificity, negative predictive values (PV-), and positive predictive values (PV+) were calculated. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICC) were determined and the differences between methods were compared by chi 2 analysis. Analysis of the areas defined by the ROC curves showed statistical differences among the three methods. When cut-off points for optimal sensitivity and specificity were chosen, the BPO-HSA assay was less sensitive and less specific and had a lower PV- and PV+ than the BPO-PLL and BPO-SP assays. Assessment of r and ICC indicated that the correlation was very high, but the concordance between the PLL and SP methods was higher than between the PLL and HSA or SP and HSA methods. We conclude that for quantitating IgE antibodies by RAST to the BPO determinant, BPO-SP or BPO-PLL conjugates offer advantages in sensitivity and specificity compared with BPO-HSA. These results support and extend previous in vitro studies by our group and highlight the importance of the carrier for RAST assays.
Shrestha, Nabin K.; Tuohy, Marion J.; Padmanabhan, Ravindran A.; Hall, Gerri S.; Procop, Gary W.
2005-01-01
We evaluated the Roche LightCycler Staphylococcus MGRADE kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci. PMID:16333115
Shrestha, Nabin K; Tuohy, Marion J; Padmanabhan, Ravindran A; Hall, Gerri S; Procop, Gary W
2005-12-01
We evaluated the Roche LightCycler Staphylococcus M(GRADE) kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci.
Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit
2015-03-01
Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.
A New Method for Assessing How Sensitivity and Specificity of Linkage Studies Affects Estimation
Moore, Cecilia L.; Amin, Janaki; Gidding, Heather F.; Law, Matthew G.
2014-01-01
Background While the importance of record linkage is widely recognised, few studies have attempted to quantify how linkage errors may have impacted on their own findings and outcomes. Even where authors of linkage studies have attempted to estimate sensitivity and specificity based on subjects with known status, the effects of false negatives and positives on event rates and estimates of effect are not often described. Methods We present quantification of the effect of sensitivity and specificity of the linkage process on event rates and incidence, as well as the resultant effect on relative risks. Formulae to estimate the true number of events and estimated relative risk adjusted for given linkage sensitivity and specificity are then derived and applied to data from a prisoner mortality study. The implications of false positive and false negative matches are also discussed. Discussion Comparisons of the effect of sensitivity and specificity on incidence and relative risks indicate that it is more important for linkages to be highly specific than sensitive, particularly if true incidence rates are low. We would recommend that, where possible, some quantitative estimates of the sensitivity and specificity of the linkage process be performed, allowing the effect of these quantities on observed results to be assessed. PMID:25068293
The Diagnostic Accuracy of Cytology for the Diagnosis of Hepatobiliary and Pancreatic Cancers.
Al-Hajeili, Marwan; Alqassas, Maryam; Alomran, Astabraq; Batarfi, Bashaer; Basunaid, Bashaer; Alshail, Reem; Alaydarous, Shahad; Bokhary, Rana; Mosli, Mahmoud
2018-06-13
Although cytology testing is considered a valuable method to diagnose tumors that are difficult to access such as hepato-biliary-pancreatic (HBP) malignancies, its diagnostic accuracy remains unclear. We therefore aimed to investigate the diagnostic accuracy of cytology testing for HBP tumors. We performed a retrospective study of all cytology samples that were used to confirm radiologically detected HBP tumors between 2002 and 2016. The cytology techniques used in our center included fine needle aspiration (FNA), brush cytology, and aspiration of bile. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated in comparison to histological confirmation. From a total of 133 medical records, we calculated an overall sensitivity of 76%, specificity of 74%, a negative likelihood ratio of 0.30, and a positive likelihood ratio of 2.9. Cytology was more accurate in diagnosing lesions of the liver (sensitivity 79%, specificity 57%) and biliary tree (sensitivity 100%, specificity 50%) compared to pancreatic (sensitivity 60%, specificity 83%) and gallbladder lesions (sensitivity 50%, specificity 85%). Cytology was more accurate in detecting primary cancers (sensitivity 77%, specificity 73%) when compared to metastatic cancers (sensitivity 73%, specificity 100%). FNA was the most frequently used cytological technique to diagnose HBP lesions (sensitivity 78.8%). Cytological testing is efficient in diagnosing HBP cancers, especially for hepatobiliary tumors. Given its relative simplicity, cost-effectiveness, and paucity of alternative diagnostic methods, cytology should still be considered as a first-line tool for diagnosing HBP malignancies. © 2018 S. Karger AG, Basel.
Negative incidental emotions augment fairness sensitivity.
Liu, Cuizhen; Chai, Jing Wen; Yu, Rongjun
2016-04-22
Previous studies have shown that task-unrelated emotions induced incidentally exert carryover effects on individuals' subsequent decisions in financial negotiations. However, the specificity of these emotion effects are not clear. In three experiments, we systematically investigated the role of seven transiently induced basic emotions (disgust, sadness, anger, fear, happiness, surprise and neutral) on rejection of unfair offers using the ultimatum game. We found that all negative emotions (disgust, sadness, anger and fear), but not happiness or surprise, significantly increased rejection rates, suggesting that the effect of incidental negative emotions on fairness is not specific to the type of negative emotion. Our findings highlight the role of fleeting emotions in biasing decision-making processes and suggest that all incidental negative emotions exert similar effects on fairness sensitivity, possibly by potentiating attention towards negative aspects of the situation.
Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H
2016-03-01
The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.
Administrative database code accuracy did not vary notably with changes in disease prevalence.
van Walraven, Carl; English, Shane; Austin, Peter C
2016-11-01
Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.
Pirro, Valentina; Hattab, Eyas M.; Cohen-Gadol, Aaron A.; Cooks, R. Graham
2016-01-01
Desorption electrospray ionization—mass spectrometry (DESI-MS) imaging was used to analyze unmodified human brain tissue sections from 39 subjects sequentially in the positive and negative ionization modes. Acquisition of both MS polarities allowed more complete analysis of the human brain tumor lipidome as some phospholipids ionize preferentially in the positive and others in the negative ion mode. Normal brain parenchyma, comprised of grey matter and white matter, was differentiated from glioma using positive and negative ion mode DESI-MS lipid profiles with the aid of principal component analysis along with linear discriminant analysis. Principal component–linear discriminant analyses of the positive mode lipid profiles was able to distinguish grey matter, white matter, and glioma with an average sensitivity of 93.2% and specificity of 96.6%, while the negative mode lipid profiles had an average sensitivity of 94.1% and specificity of 97.4%. The positive and negative mode lipid profiles provided complementary information. Principal component–linear discriminant analysis of the combined positive and negative mode lipid profiles, via data fusion, resulted in approximately the same average sensitivity (94.7%) and specificity (97.6%) of the positive and negative modes when used individually. However, they complemented each other by improving the sensitivity and specificity of all classes (grey matter, white matter, and glioma) beyond 90% when used in combination. Further principal component analysis using the fused data resulted in the subgrouping of glioma into two groups associated with grey and white matter, respectively, a separation not apparent in the principal component analysis scores plots of the separate positive and negative mode data. The interrelationship of tumor cell percentage and the lipid profiles is discussed, and how such a measure could be used to measure residual tumor at surgical margins. PMID:27658243
Laserson, K F; Petralanda, I; Hamlin, D M; Almera, R; Fuentes, M; Carrasquel, A; Barker, R H
1994-02-01
We have examined the reproducibility, sensitivity, and specificity of detecting Plasmodium falciparum using the polymerase chain reaction (PCR) and the species-specific probe pPF14 under field conditions in the Venezuelan Amazon. Up to eight samples were field collected from each of 48 consenting Amerindians presenting with symptoms of malaria. Sample processing and analysis was performed at the Centro Amazonico para la Investigacion y Control de Enfermedades Tropicales Simon Bolivar. A total of 229 samples from 48 patients were analyzed by PCR methods using four different P. falciparum-specific probes. One P. vivax-specific probe and by conventional microscopy. Samples in which results from PCR and microscopy differed were reanalyzed at a higher sensitivity by microscopy. Results suggest that microscopy-negative, PCR-positive samples are true positives, and that microscopy-positive and PCR-negative samples are true negatives. The sensitivity of the DNA probe/PCR method was 78% and its specificity was 97%. The positive predictive value of the PCR method was 88%, and the negative predictive value was 95%. Through the analysis of multiple blood samples from each individual, the DNA probe/PCR methodology was found to have an inherent reproducibility that was highly statistically significant.
Negative incidental emotions augment fairness sensitivity
Liu, Cuizhen; Chai, Jing Wen; Yu, Rongjun
2016-01-01
Previous studies have shown that task-unrelated emotions induced incidentally exert carryover effects on individuals’ subsequent decisions in financial negotiations. However, the specificity of these emotion effects are not clear. In three experiments, we systematically investigated the role of seven transiently induced basic emotions (disgust, sadness, anger, fear, happiness, surprise and neutral) on rejection of unfair offers using the ultimatum game. We found that all negative emotions (disgust, sadness, anger and fear), but not happiness or surprise, significantly increased rejection rates, suggesting that the effect of incidental negative emotions on fairness is not specific to the type of negative emotion. Our findings highlight the role of fleeting emotions in biasing decision-making processes and suggest that all incidental negative emotions exert similar effects on fairness sensitivity, possibly by potentiating attention towards negative aspects of the situation. PMID:27101931
Rehem, Tania Cristina Morais Santa Barbara; de Oliveira, Maria Regina Fernandes; Ciosak, Suely Itsuko; Egry, Emiko Yoshikawa
2013-01-01
To estimate the sensitivity, specificity and positive and negative predictive values of the Unified Health System's Hospital Information System for the appropriate recording of hospitalizations for ambulatory care-sensitive conditions. The hospital information system records for conditions which are sensitive to ambulatory care, and for those which are not, were considered for analysis, taking the medical records as the gold standard. Through simple random sampling, a sample of 816 medical records was defined and selected by means of a list of random numbers using the Statistical Package for Social Sciences. The sensitivity was 81.89%, specificity was 95.19%, the positive predictive value was 77.61% and the negative predictive value was 96.27%. In the study setting, the Hospital Information System (SIH) was more specific than sensitive, with nearly 20% of care sensitive conditions not detected. There are no validation studies in Brazil of the Hospital Information System records for the hospitalizations which are sensitive to primary health care. These results are relevant when one considers that this system is one of the bases for assessment of the effectiveness of primary health care.
Optical coherence tomography in the diagnosis of dysplasia and adenocarcinoma in Barret's esophagus
NASA Astrophysics Data System (ADS)
Gladkova, N. D.; Zagaynova, E. V.; Zuccaro, G.; Kareta, M. V.; Feldchtein, F. I.; Balalaeva, I. V.; Balandina, E. B.
2007-02-01
Statistical analysis of endoscopic optical coherence tomography (EOCT) surveillance of 78 patients with Barrett's esophagus (BE) is presented in this study. The sensitivity of OCT device in retrospective open detection of early malignancy (including high grade dysplasia and intramucosal adenocarcinoma (IMAC)) was 75%, specificity 82%, diagnostic accuracy - 80%, positive predictive value- 60%, negative predictive value- 87%. In the open recognition of IMAC sensitivity was 81% and specificity were 85% each. Results of a blind recognition with the same material were similar: sensitivity - 77%, specificity 85%, diagnostic accuracy - 82%, positive predictive value- 70%, negative predictive value- 87%. As the endoscopic detection of early malignancy is problematic, OCT holds great promise in enhancing the diagnostic capability of clinical GI endoscopy.
Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf
2017-12-01
The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.
Mkony, Martha Franklin; Mizinduko, Mucho Michael; Massawe, Augustine; Matee, Mecky
2014-12-05
We determined the accuracy of Rubarth's newborn scale of sepsis and C- reactive protein in diagnosing neonatal sepsis and assessed antimicrobial susceptibility pattern of etiological bacteria. This cross sectional study was conducted at Muhimbili National Hospital in Dar es Salaam, Tanzania between July 2012 and March 2013. Neonates suspected to have sepsis underwent physical examination using Rubarth's newborn scale of sepsis (RNSOS). Blood was taken for culture and antimicrobial sensitivity testing, full blood picture and C - reactive protein (CRP) performed 12 hours apart. The efficacy of RNSOS and serial CRP was assessed by calculating sensitivity, specificity, negative and positive predictive values, receiver operating characteristics (ROC) analysis as well as likelihood ratios (LHR) with blood culture result used as a gold standard. Out of 208 blood samples, 19.2% had a positive blood culture. Single CRP had sensitivity and specificity of 87.5% and 70.9% respectively, while RNSOS had sensitivity of 65% and specificity of 79.7%. Serial CRP had sensitivity of 69.0% and specificity of 92.9%. Combination of CRP and RNSOS increased sensitivity to 95.6% and specificity of 56.4%. Combination of two CRP and RNSOS decreased sensitivity to 89.1% but increased specificity to 74%. ROC for CRP was 0.86; and for RNSOS was 0.81. For CRP the LHR for positive test was 3 while for negative test was 0.18, while for RNSOS the corresponding values were 3.24 and for negative test was 0.43. Isolated bacteria were Klebsiella spp 14 (35%), Escherichia coli 12 (22.5%), Coagulase negative staphlococci 9 (30%), Staphylococcus aureus 4 (10%), and Pseudomonas spp 1 (2.5%). The overall resistance to the WHO recommended first line antibiotics was 100%, 92% and 42% for cloxacillin, ampicillin and gentamicin, respectively. For the second line drugs resistance was 45%, 40%, and 7% for ceftriaxone, vancomycin and amikacin respectively. Single CRP in combination with RNSOS can be used for rapid identification of neonates with sepsis due to high sensitivity (95.6%) but cannot exclude those without sepsis due to low specificity (56.4%). Serial CRP done 12hrs apart can be used to exclude non-cases. This study demonstrated very high levels of resistance to the first-line antibiotics.
Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti
2018-06-01
The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of operatively treated proximal femoral fractures seen in the study, sensitivity of CT was 60% (3/5) and negative predictive value was 97%, although the relatively few patients needing fixation precludes statistical analysis.
Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor
2017-03-01
To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.
Noël, Audrey; Berhin, Catherine; Hoebeke, Martin; Bouchahrouf, Warda; Yunus, Sami; Bogaerts, Pierre; Glupczynski, Youri
2016-01-01
ABSTRACT Four screening assays aimed for rapid detection of carbapenemase production from Gram-negative bacterial isolates, i.e., the Neo-Rapid Carb kit (Rosco Diagnostica A/S), the Rapidec Carba NP test (bioMérieux SA), the β Carba test (Bio-Rad Laboratories N.V.), and a homemade electrochemical assay (BYG Carba test) were evaluated against a panel comprising 328 clinical isolates (Enterobacteriaceae [n = 198] and nonfermentative Gram-negative bacilli [n = 130]) with previously characterized resistance mechanisms to carbapenems. Among Enterobacteriaceae isolates, the BYG Carba test and the β Carba test showed excellent sensitivities (respectively, 100% and 97.3%) and specificities (respectively, 98.9% and 97.7%). The two other assays yielded poorer performances with sensitivity and specificity of 91.9% and 83.9% for the Rapidec Carba NP test and of 89.2% and 89.7% for the Neo-Rapid Carb kit, respectively. Among Pseudomonas spp., sensitivities and specificities ranged, respectively, from 87.3% to 92.7% and from 88.2% to 94.1%. Finally, all tests performed poorly against Acinetobacter spp., with sensitivities and specificities, respectively, ranging from 27.3% to 75.8% and from 75 to 100%. Among commercially available assays, the β Carba test appeared to be the most convenient for routine use and showed the best overall performances, especially against OXA-48-like producers. The excellent performance of the BYG Carba test against Enterobacteriaceae was confirmed (100% sensitivity and 98.9% specificity). PMID:27927915
Nadri, Johara; Sauvageot, Delphine; Njanpop-Lafourcade, Berthe-Marie; Baltazar, Cynthia S; Banla Kere, Abiba; Bwire, Godfrey; Coulibaly, Daouda; Kacou N'Douba, Adele; Kagirita, Atek; Keita, Sakoba; Koivogui, Lamine; Landoh, Dadja E; Langa, Jose P; Miwanda, Berthe N; Mutombo Ndongala, Guy; Mwakapeje, Elibariki R; Mwambeta, Jacob L; Mengel, Martin A; Gessner, Bradford D
2018-04-01
During 2014, Africa reported more than half of the global suspected cholera cases. Based on the data collected from seven countries in the African Cholera Surveillance Network (Africhol), we assessed the sensitivity, specificity, and positive and negative predictive values of clinical cholera case definitions, including that recommended by the World Health Organization (WHO) using culture confirmation as the gold standard. The study was designed to assess results in real-world field situations in settings with recent cholera outbreaks or endemicity. From June 2011 to July 2015, a total of 5,084 persons with suspected cholera were tested for Vibrio cholerae in seven different countries of which 35.7% had culture confirmation. For all countries combined, the WHO case definition had a sensitivity = 92.7%, specificity = 8.1%, positive predictive value = 36.1%, and negative predictive value = 66.6%. Adding dehydration, vomiting, or rice water stools to the case definition could increase the specificity without a substantial decrease in sensitivity. Future studies could further refine our findings primarily by using more sensitive methods for cholera confirmation.
Vélez Lopera, Johana María; Berbesí Fernández, Dedsy; Cardona Arango, Doris; Segura Cardona, Angela; Ordóñez Molina, Jaime
2012-07-01
To determine which abbreviated Zarit Scale (ZS) better evaluates the burden of the caregiver of an elderly patient in Medellin, Colombia. Validation study. Primary Care setting in the city of Medellin. Primary caregiver of dependent elderly patients over 65 years old. Sensitivity, specificity, positive predictive value, and negative predictive value for the different abbreviated Zarit scales, plus performing a reliability analysis using the Cronbach Alpha coefficient. The abbreviated scales obtained a sensitivity of between 36.84 and 81.58%, specificity between 95.99 and 100%, positive predictive values between 71.05 and 100%, and negative predictive values of between 91.64 and 97.42%. The scale that better determined caregiver burden in Primary Care was the Bedard Screening scale, with a sensitivity of 81.58%, a specificity of 96.35% and positive and negative predictive values of 75.61% and 97.42%, respectively. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa
2017-01-17
Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
Occupancy Modeling for Improved Accuracy and Understanding of Pathogen Prevalence and Dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmon Oncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population: Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/ metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%. PMID:25738709
Occupancy modeling for improved accuracy and understanding of pathogen prevalence and dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmonOncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population:Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%.
Dialysate bacterial endotoxin as a prognostic indicator of peritoneal dialysis related peritonitis.
Szeto, Cheuk-Chun; Lai, Ka-Bik; Chow, Kai-Ming; Kwan, Bonnie Ching-Ha; Law, Man-Ching; Pang, Wing-Fai; Ma, Terry King-Wing; Leung, Chi-Bon; Li, Philip Kam-Tao
2016-12-01
Peritonitis is the major complication of peritoneal dialysis (PD). The aim of our present study is to explore the prognostic value of endotoxin level in PD effluent for the prediction of treatment failure in PD-related peritonitis. We studied 325 peritonitis episodes in 223 patients. PD effluent (PDE) was collected every 5 days for endotoxin level and leukocyte count. Patients were followed for relapsing or recurrent peritonitis. We found 20 episodes (6.2%) had primary treatment failure; 41 (12.6%) developed relapsing, 19 (5.8%) had recurrent, and 22 (6.8%) had repeat episodes. Endotoxin was detectable in the PDE of 19 episodes (24.4%) caused by Gram negative organisms, 4 episodes (6.8%) of mixed bacterial growth, and none of the culture negative episodes or those by Gram positive organisms. For episodes caused by Gram negative bacteria, a detectable endotoxin level in PDE on day 5 had a sensitivity and specificity of 66.7% and 83.3%, respectively, for predicting primary treatment failure. In contrast, PDE leukocyte count > 1000 per mm3 on day 5 had a sensitivity and specificity of 88.9% and 89.1%, respectively; the addition of PDE endotoxin assay did not improve the sensitivity or specificity. We conclude that detectable endotoxin in PDE 5 days after antibiotic therapy might predict primary treatment failure in peritonitis episodes caused by Gram negative organisms. However, the sensitivity and specificity of PDE endotoxin assay was inferior to PDE leukocyte count. © 2016 Asian Pacific Society of Nephrology.
Sousa, Bruno
2013-01-01
Objective To translate into Portuguese and evaluate the measuring properties of the Sunderland Scale and the Cubbin & Jackson Revised Scale, which are instruments for evaluating the risk of developing pressure ulcers during intensive care. Methods This study included the process of translation and adaptation of the scales to the Portuguese language, as well as the validation of these tools. To assess the reliability, Cronbach alpha values of 0.702 to 0.708 were identified for the Sunderland Scale and the Cubbin & Jackson Revised Scale, respectively. The validation criteria (predictive) were performed comparatively with the Braden Scale (gold standard), and the main measurements evaluated were sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve, which were calculated based on cutoff points. Results The Sunderland Scale exhibited 60% sensitivity, 86.7% specificity, 47.4% positive predictive value, 91.5% negative predictive value, and 0.86 for the area under the curve. The Cubbin & Jackson Revised Scale exhibited 73.3% sensitivity, 86.7% specificity, 52.4% positive predictive value, 94.2% negative predictive value, and 0.91 for the area under the curve. The Braden scale exhibited 100% sensitivity, 5.3% specificity, 17.4% positive predictive value, 100% negative predictive value, and 0.72 for the area under the curve. Conclusions Both tools demonstrated reliability and validity for this sample. The Cubbin & Jackson Revised Scale yielded better predictive values for the development of pressure ulcers during intensive care. PMID:23917975
Kawamura, Masaki; Kobayashi, Naomi; Inaba, Yutaka; Choe, Hyonmin; Tezuka, Taro; Kubota, So; Saito, Tomoyuki
2017-11-01
A new multiplex real-time polymerase chain reaction (PCR) assay was developed to detect methicillin-resistant Staphylococcus (MRS) and to distinguish between gram-positive and gram-negative bacteria. In this study, we validated the sensitivity and specificity of this assay with periprosthetic joint infections (PJIs) and evaluated the utility of PCR for culture-negative PJI. Forty-five samples from 23 infectious PJI cases and 106 samples from 64 non-infectious control cases were analyzed by real-time PCR using a LightCycler Nano ® system. Twenty-eight clinical samples, comprising bacteria of known species isolated consecutively in the microbiological laboratory of our hospital, were used to determine the spectrum of bacterial species that could be detected using the new multiplex primers and probes. The sensitivity and specificity of the MRS- and universal-PCR assays were 92% and 99%, and 91% and 88%, respectively. Twenty-eight species of clinically isolated bacteria were detected using this method and the concordance rate for the identification of gram-positive or gram-negative organisms was 96%. Eight samples were identified as PCR-positive despite a culture-negative result. This novel multiplex real-time PCR system has acceptable sensitivity and specificity and several advantages; therefore, it has potential use for the diagnosis of PJIs, particularly in culture-negative cases.
Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita
2010-01-01
Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832
Yaffe, Beril; Walder, Deborah J
2016-05-30
Attentional-interference using emotional Stroop tasks (ESTs) is greater among individuals in the general population with positive (versus negative) schizotypal traits; specifically in response to negatively (versus positively) valenced words, potentially capturing threat-sensitivity. Variability in attentional-interference as a function of subcategories of negatively valenced words (and in relation to schizotypal traits) remains underexplored in EST studies. We examined attentional-interference across negative word subcategories (fear/anger/sadness/disgust), and in relation to positive schizotypy, among non-clinical individuals in the general population reporting varying degrees of schizotypal traits. As hypothesized, performance differed across word subcategories, though the pattern varied from expectation. Attentional-interference was greater for fear and sadness compared to anger; and analogous for fear, disgust, and sadness. In the high schizotypy group, positive schizotypal traits were directly associated with attentional-interference to disgust. Attentional-interference was comparable between high- and low-positive schizotypy. Results suggest negative emotion subcategories may differentially reflect threat-sensitivity. Disgust-sensitivity may be particularly salient in (non-clinical) positive schizotypy. Findings have implications for understanding negative emotion specificity and variability in stimulus presentation modality when studying threat-related attentional-interference. Finally, disgust-related attentional-interference may serve as a cognitive correlate of (non-clinical) positive schizotypy. Expanding this research to prodromal populations will help explore disgust-related attentional-interference as a potential cognitive marker of positive symptoms. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu
2017-04-17
Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum samples. Fourteen (53.8%) samples had valid results with LPA among the 26 smear negative culture positive samples. The remaining 8 (30.8%) and 4 (15.4%) were invalid and negative with LPA, respectively. The sensitivity and specificity of Genotype MTBDRplus VER 2.0 LPA were 100% for the detection of MDR-TB among 14 direct smear negative and culture positive sputum samples. The most common mutations associated with RMP and INH resistance were S531L and S315TL, respectively. A single rare mutation (C15T/A16G) was detected for INH resistance. The diagnostic performance of Genotype MTBDRplus VER 2.0 LPA in direct smear positive sputum sample was highly sensitive and specific for early detection of MDR-TB. However, the diagnostic performance of this molecular assay in direct smear negative sputum sample was low and showed a high level of invalid results for detection of M. tuberculosis and its resistance to RMP and/or INH so it is unlikely to implement Genotype MTBDRplus VER 2.0 for the detection of MDR-TB in direct smear negative sample in our routine settings. The sensitivity of the assay should be improved for detection of MDR-TB in direct smear negative sputum specimens.
Performance characteristics of broth-only cultures after revision total joint arthroplasty.
Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P
2014-11-01
Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.
Ahmed, Ayesha; Ahmed, Sajjad
2004-01-01
The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.
A 3-Year Study of Predictive Factors for Positive and Negative Appendicectomies.
Chang, Dwayne T S; Maluda, Melissa; Lee, Lisa; Premaratne, Chandrasiri; Khamhing, Srisongham
2018-03-06
Early and accurate identification or exclusion of acute appendicitis is the key to avoid the morbidity of delayed treatment for true appendicitis or unnecessary appendicectomy, respectively. We aim (i) to identify potential predictive factors for positive and negative appendicectomies; and (ii) to analyse the use of ultrasound scans (US) and computed tomography (CT) scans for acute appendicitis. All appendicectomies that took place at our hospital from the 1st of January 2013 to the 31st of December 2015 were retrospectively recorded. Test results of potential predictive factors of acute appendicitis were recorded. Statistical analysis was performed using Fisher exact test, logistic regression analysis, sensitivity, specificity, and positive and negative predictive values calculation. 208 patients were included in this study. 184 patients had histologically proven acute appendicitis. The other 24 patients had either nonappendicitis pathology or normal appendix. Logistic regression analysis showed statistically significant associations between appendicitis and white cell count, neutrophil count, C-reactive protein, and bilirubin. Neutrophil count was the test with the highest sensitivity and negative predictive values, whereas bilirubin was the test with the highest specificity and positive predictive values (PPV). US and CT scans had high sensitivity and PPV for diagnosing appendicitis. No single test was sufficient to diagnose or exclude acute appendicitis by itself. Combining tests with high sensitivity (abnormal neutrophil count, and US and CT scans) and high specificity (raised bilirubin) may predict acute appendicitis more accurately.
Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.
2013-01-01
Background Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. Objective To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. Methods In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). Results The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m2. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Conclusion Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction. PMID:24061685
van de Groep, Kirsten; Bos, Martine P; Savelkoul, Paul H M; Rubenjan, Anna; Gazenbeek, Christel; Melchers, Willem J G; van der Poll, Tom; Juffermans, Nicole P; Ong, David S Y; Bonten, Marc J M; Cremer, Olaf L
2018-04-26
Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.
Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan
2016-01-01
Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P < 0.001. Parallel testing of histological AFB staining and PCR showed the sensitivity, specificity, PPV, NPV, and accuracy to be 94.0% (125/133), 95.8% (46/48), 98.4% (125/127), 85.2% (46/54), and 94.5% (171/181), respectively. Among patients with positive AFB and negative PCR results in lung tissue specimens, two were diagnosed with NTM infections (Mycobacterium avium-intracellulare complex and Mycobacterium kansasii). Nucleic acid amplification testing combined with acid-fast staining in lung biopsy tissues can lead to early and accurate diagnosis in patients with smear-negative pulmonary tuberculosis. For patients with positive histological AFB and negative tuberculous PCR results in lung tissue, NTM infection should be suspected and could be identified by specific probe assays or 16S rRNA sequencing.
Kurt, Habibe; Bueso-Ramos, Carlos E; Khoury, Joseph D; Routbort, Mark J; Kanagal-Shamanna, Rashmi; Patel, Umang V; Jorgensen, Jeffrey L; Wang, Sa A; Ravandi, Farhad; DiNardo, Courtney; Luthra, Rajyalakshmi; Medeiros, L Jeffrey; Patel, Keyur P
2018-05-01
Isocitrate dehydrogenase 1 (IDH1) and IDH2 mutations occur in a variety of myeloid neoplasms. Immunohistochemistry (IHC)-based direct visualization of mutant clones of hematopoietic cells can be useful for rapid diagnostic screening and for monitoring treatment response. In this study, we first evaluated the sensitivity and specificity of the IDH1 p.R132H mutation-specific antibody by IHC. All IDH1 wild type cases (n=11) and IDH1 mutant cases with a non-p.R132H mutation (n=30) were negative by IHC, demonstrating 100% antibody specificity. All the initial diagnostic specimens with IDH1 p.R132H mutation including acute myeloid leukemia (n=30), myelodysplastic syndromes (MDS) (n=10), MDS/myeloproliferative neoplasms (MPN) (n=4), and MPN (n=5) were positive by IHC, demonstrating 100% antibody sensitivity. Both immature and mature myeloid cells showed immunoreactivity. Erythroid precursors, lymphoid cells, endothelial cells, and osteoblasts were consistently negative by IHC. We then evaluated the follow-up specimens with a known IDH1 mutation status including acute myeloid leukemia (n=23), MDS (n=2), MDS/MPN (n=2), and MPN (n=2). Thirty-three IDH1 p.R132H mutant cases were positive by IHC and 12 IDH1 mutation negative cases were negative by IHC. However, IHC reactivity in up to 25% of bone marrow cells was noted in 8 of 20 polymerase chain reaction-negative cases, all from patients with a known history of IDH1 p.R132H mutation indicating sampling error or a sensitivity issue with molecular tests. These data indicate that IHC is a highly specific and sensitive tool to detect IDH1 p.R132H mutation in bone marrow involved by myeloid neoplasms. In addition, IDH1 p.R132H IHC also allows localization and assessment of the maturation stage of the clones carrying the mutation.
Weitzel, T; Schnabel, E; Dieckmann, S; Börner, U; Schweiger, B
2007-07-01
Point-of-care (POC) tests for influenza facilitate clinical case management, and might also be helpful in the care of travellers who are at special risk for influenza infection. To evaluate influenza POC testing in travellers, a new assay, the ImmunoCard STAT! Flu A and B, was used to investigate travellers presenting with influenza-like symptoms. Influenza virus infection was diagnosed in 27 (13%) of 203 patients by influenza virus-specific PCR and viral culture. The POC test had sensitivity and specificity values of 64% and 99% for influenza A, and 67% and 100% for influenza B, respectively. Combined sensitivity and specificity were 67% and 99%, respectively, yielding positive and negative predictive values of 95%, and positive and negative likelihood ratios of 117 and 0.34, respectively. The convenient application, excellent specificity and high positive likelihood ratio of the POC test allowed rapid identification of influenza cases. However, negative test results might require confirmation by other methods because of limitations in sensitivity. Overall, influenza POC testing appeared to be a useful tool for the management of travellers with influenza-like symptoms.
Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran
2013-01-01
Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.
Pires, Frederico Ribeiro; Franco, Andréia Christine Bonotto Farias; Gilio, Alfredo Elias; Troster, Eduardo Juan
2017-01-01
To evaluate Bacterial Meningitis Score (BMS) on its own and in association with Cerebrospinal Fluid (CSF) lactate dosage in order to distinguish bacterial from aseptic meningitis. Children diagnosed with meningitis at a tertiary hospital between January/2011 and December/2014 were selected. All data were obtained upon admission. BMS was applied and included: CSF Gram staining (2 points); CSF neutrophil count ≥1,000 cells/mm3 (1 point); CSF protein ≥80 mg/dL (1 point); peripheral blood neutrophil count ≥10,000 cells/mm3 (1 point) and seizures upon/before arrival (1 point). Cutoff value for CSF lactate was ≥30 mg/dL. Sensitivity, specificity and negative predictive value of several BMS cutoffs and BMS associated with high CSF lactate were evaluated for prediction of bacterial meningitis. Among 439 eligible patients, 94 did not have all data available to complete the score, and 345 patients were included: 7 in bacterial meningitis group and 338 in aseptic meningitis group. As predictive factors of bacterial meningitis, BMS ≥1 had 100% sensitivity (95%CI 47.3-100), 64.2% specificity (58.8-100) and 100% negative predictive value (97.5-100); BMS ≥2 or BMS ≥1 associated with high CSF lactate also showed 100% sensitivity (47.3-100); but 98.5% specificity (96.6-99.5) and 100% negative predictive value (98.3-100). 2 point BMS in association with CSF lactate dosage had the same sensitivity and negative predictive value, with increased specificity for diagnosis of bacterial meningitis when compared with 1-point BMS.
Lantos, Joshua E; Levine, Marc S; Rubesin, Stephen E; Lau, Charles T; Torigian, Drew A
2013-03-01
To assess the diagnostic performance of esophagography and chest computed tomography (CT) for detecting leaks after esophagectomy and gastric pull-through. Our database revealed 29 patients who had undergone esophagography and chest CT after esophagectomy. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for postoperative leaks were determined for esophagography and CT, separately and combined, on the basis of a retrospective image review. Patients were also stratified for esophagograms with water-soluble contrast alone versus water-soluble contrast and high-density barium and for CT with and without oral contrast. Our findings were retrospectively compared with those reported at initial image interpretation. Clinically relevant leaks were present in 14 (48%) of 29 patients after esophagectomy. Esophagography had a sensitivity of 79%, specificity of 73%, PPV of 73%, and NPV of 79% for detecting leaks, whereas CT had a sensitivity of 86%, specificity of 33%, PPV of 55%, and NPV of 71% and esophagography and CT combined had a sensitivity of 100%, specificity of 27%, PPV of 56%, and NPV of 100%. The sensitivity of esophagography increased with high-density barium, whereas the sensitivity of CT was the same with and without oral contrast agent. Finally, esophagography and CT were seen to have a higher sensitivity and lower specificity on retrospective review compared with the results reported at initial image interpretation. Esophagography had a slightly lower sensitivity and substantially higher specificity compared with CT for detecting leaks after esophagectomy, whereas esophagography and CT combined had a sensitivity of 100% for detecting leaks. Therefore, postoperative leaks can be excluded with confidence after esophagectomy when both tests are negative.
Scherer, Luciene Cardoso; Sperhacke, Rosa Dea; Jarczewski, Carla; Cafrune, Patrícia I; Minghelli, Simone; Ribeiro, Marta Osório; Mello, Fernanda CQ; Ruffino-Netto, Antonio; Rossetti, Maria LR; Kritski, Afrânio L
2007-01-01
Background Smear-negative pulmonary tuberculosis (SNPTB) accounts for 30% of Pulmonary Tuberculosis (PTB) cases reported annually in developing nations. Polymerase chain reaction (PCR) may provide an alternative for the rapid detection of Mycobacterium tuberculosis (MTB); however little data are available regarding the clinical utility of PCR in SNPTB, in a setting with a high burden of TB/HIV co-infection. Methods To evaluate the performance of the PCR dot-blot in parallel with pretest probability (Clinical Suspicion) in patients suspected of having SNPTB, a prospective study of 213 individuals with clinical and radiological suspicion of SNPTB was carried out from May 2003 to May 2004, in a TB/HIV reference hospital. Respiratory specialists estimated the pretest probability of active disease into high, intermediate, low categories. Expectorated sputum was examined by direct microscopy (Ziehl-Neelsen staining), culture (Lowenstein Jensen) and PCR dot-blot. Gold standard was based on culture positivity combined with the clinical definition of PTB. Results In smear-negative and HIV subjects, active PTB was diagnosed in 28.4% (43/151) and 42.2% (19/45), respectively. In the high, intermediate and low pretest probability categories active PTB was diagnosed in 67.4% (31/46), 24% (6/25), 7.5% (6/80), respectively. PCR had sensitivity of 65% (CI 95%: 50%–78%) and specificity of 83% (CI 95%: 75%–89%). There was no difference in the sensitivity of PCR in relation to HIV status. PCR sensitivity and specificity among non-previously TB treated and those treated in the past were, respectively: 69%, 43%, 85% and 80%. The high pretest probability, when used as a diagnostic test, had sensitivity of 72% (CI 95%:57%–84%) and specificity of 86% (CI 95%:78%–92%). Using the PCR dot-blot in parallel with high pretest probability as a diagnostic test, sensitivity, specificity, positive and negative predictive values were: 90%, 71%, 75%, and 88%, respectively. Among non-previously TB treated and HIV subjects, this approach had sensitivity, specificity, positive and negative predictive values of 91%, 79%, 81%, 90%, and 90%, 65%, 72%, 88%, respectively. Conclusion PCR dot-blot associated with a high clinical suspicion may provide an important contribution to the diagnosis of SNPTB mainly in patients that have not been previously treated attended at a TB/HIV reference hospital. PMID:18096069
LaPrade, Robert F; Ho, Charles P; James, Evan; Crespo, Bernardo; LaPrade, Christopher M; Matheny, Lauren M
2015-01-01
The purpose of this study was to determine the diagnostic accuracy of 3 T MRI, including sensitivity, specificity, negative and positive predictive values, for detection of posterior medial and lateral meniscus root tears and avulsions. All patients who had a 3 T MRI of the knee, followed by arthroscopic surgery, were included in this study. Arthroscopy was considered the gold standard. Meniscus root tears diagnosed at arthroscopy and on MRI were defined as a complete meniscus root detachment within 9 mm of the root. All surgical data were collected prospectively and stored in a data registry. MRI exams were reported prospectively by a musculoskeletal radiologist and reviewed retrospectively. There were 287 consecutive patients (156 males, 131 females; mean age 41.7 years) in this study. Prevalence of meniscus posterior root tears identified at arthroscopy was 9.1, 5.9% for medial and 3.5% for lateral root tears (one patient had both). Sensitivity was 0.770 (95% CI 0.570, 0.901), specificity was 0.729 (95% CI 0.708, 0.741), positive predictive value was 0.220 (95% CI 0.163, 0.257) and negative predictive value was 0.970 (95% CI 0.943, 0.987). For medial root tears, sensitivity was 0.824 (95% CI 0.569, 0.953), specificity was 0.800 (95% CI 0.784, 0.808), positive predictive value was 0.206 (95% CI 0.142, 0.238) and negative predictive value was 0.986 (95% CI 0.967, 0.996). For lateral meniscus posterior root tears, sensitivity was 0.600 (95% CI 0.281, 0.860), specificity was 0.903 (95% CI 0.891, 0.912), positive predictive value was 0.181 (95% CI 0.085, 0.261) and negative predictive value was 0.984 (95% CI 0.972, 0.994). This study demonstrated moderate sensitivity and specificity of 3 T MRI to detect posterior meniscus root tears. The negative predictive value of 3 T MRI to detect posterior meniscus root tears was high; however, the positive predictive value was low. Sensitivity was higher for medial root tears, indicating a higher risk of missing lateral root tears on MRI. Imaging has an important role in identifying meniscus posterior horn root tears; however, some root tears may not be identified until arthroscopy. Prognostic study (diagnostic), Level II.
Ullah, Irfan; Javaid, Arshad; Masud, Haleema; Ali, Mazhar; Basit, Anila; Ahmad, Waqas; Younis, Faisal; Yasmin, Rehana; Khan, Afsar; Jabbar, Abdul; Husain, Masroor; Butt, Zahid Ahmad
2017-04-01
Tuberculosis (TB) is a serious public health problem in developing countries such as Pakistan. Rapid diagnosis of TB and detection of drug resistance are very important for timely and appropriate management of multidrug-resistant TB (MDR-TB). The purpose of this study was to determine the diagnostic efficacy of the Xpert MTB/RIF assay for rapid diagnosis of TB and detection of rifampicin (RIF) resistance in extrapulmonary and smear-negative pulmonary TB suspects. A total of 98 bronchoalveolar lavage fluid (BALF) and 168 extrapulmonary specimens were processed by Xpert MTB/RIF. Culture results are considered as the gold standard for diagnosis of TB, and drug susceptibility testing for detection of RIF resistance. Diagnostic efficacy was measured in terms of sensitivity, specificity and positive and negative predictive values. The Xpert MTB/RIF assay detected 40 (40.8 %) of 98 BALF of presumptive pulmonary TB and 60 (35.7 %) of 168 extrapulmonary specimens. Sensitivity and specificity of the Xpert MTB/RIF assay for detection of TB was 86 and 88.4 %, respectively. The positive predictive value was 71.5 % while negative predictive value was 95.1 %. The Xpert MTB/RIF assay is a rapid and simple technique with high sensitivity and specificity for diagnosing TB and detecting drug resistance in extrapulmonary and smear-negative TB cases.
Bil-Lula, Iwona; Matuszek, Patryk; Pfeiffer, Thomas; Woźniak, Mieczysław
2015-01-01
Infections of Borrelia burgdorferi sensu lato reveal clinical manifestations affecting numerous organs and tissues. The standard diagnostic procedure of these infections is quite simple if a positive history of tick exposure or typical erythema migrans appears. Lack of unequivocal clinical symptoms creates the necessity for further evaluation with laboratory tests. This study discusses the utility of a novel, improved, well-optimized, sensitive and highly specific quantitative real-time PCR assay for the diagnostics of infections caused by Borrelia burgdorferi sensu lato. We designed an improved, specific, highly sensitive real-time quantitative polymerase chain reaction (RQ-PCR) assay for the detection and quantification of all Borrelia burgdorferi genotypes. A wide validation effort was undertaken to ensure confidence in the highly sensitive and specific detection of B. burgdorferi. Due to high sensitivity and great specificity, as low as 1.6×10² copies of Borrelia per mL of whole blood could be detected. As much as 12 (3%) negative ELISA IgM results, 14 (2.8%) negative results of Line blot IgM, 11 (3.1%) and 7 (2.7%) of negative ELISA IgG and Line blot IgG results, respectively, were positive in real-time PCR. The data in this study confirms the high positive predictive value of real-time PCR test in the detection of Borrelia infections.
Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang
2016-06-01
Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.
Sjoholm-Gomez de Liano, Carl; Soberon-Ventura, Vidal F; Salcedo-Villanueva, Guillermo; Santos-Palacios, Abril; Guerrero-Naranjo, Jose Luis; Fromow-Guerra, Jans; García-Aguirre, Gerardo; Morales-Canton, Virgilio; Velez-Montoya, Raul
2017-01-01
To assess the sensitivity, specificity, positive predictive value and negative predictive value of anterior chamber tap for the diagnosis of bacterial endophthalmitis on a population with high prevalence. Retrospective, single centre, case series study. We reviewed all medical records with clinical diagnosis of bacterial endophthalmitis in our hospital from January 1st, 2000 to December 31st 2014. From each record, we documented general demographic data, best corrected visual acuity and vitreous and aqueous tap microbiological results. All cases were further divided according to the endophthalmitis aetiology to perform individual calculations of sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence. We used the results of the vitreous tap as the gold standard for diagnosis of bacterial endophthalmitis. We excluded those records in which the aqueous and vitreous samples were not taken simultaneously or had an incomplete microbiological report. Significance were assessed with chi squared statistics, with an alpha value of 0.05 for statistical significance. A total of 190 cases fulfilled the inclusion/exclusion criteria. Positive culture rate from vitreous samples was 64.74%. Positive culture rate from aqueous sample was 32.11%. Bacteria isolated from aqueous samples matched those isolated from vitreous samples 78.68% of the time. The overall sensitivity was 38.21%, specificity: 75.51%, positive predictive value: 79.66%, negative predictive value: 32.74% ( p = 0.08). Subgroup analysis showed that anterior chamber taps in cases of post-surgical endophthalmitis had a moderate to low sensitivity (37.73%), high specificity (93%) and high positive predictive value (95%) ( p < 0.04). The sensitivity and specificity of anterior chamber tap are low and should not be used for critical therapeutic decisions in patients with suspected bacterial endophthalmitis. In cases of post-surgical endophthalmitis, the result of an anterior chamber tap could be used for therapeutic guidance, but only in conjunction with clinical presentation and in the absence of a better method for diagnosis.
A highly sensitive and specific combined clinical and sonographic score to diagnose appendicitis.
Reddy, Swathi B; Kelleher, Michael; Bokhari, S A Jamal; Davis, Kimberly A; Schuster, Kevin M
2017-10-01
Computed tomography (CT) scanning reduces the negative appendectomy rate however it exposes the patient to ionizing radiation. Ultrasound (US) does not carry this risk but may be nondiagnostic. We hypothesized that a clinical-US scoring system would improve diagnostic accuracy. We conducted a retrospective review of all patients (age, >15 years) who presented through the emergency department with suspected appendicitis and underwent initial US. A US score was developed using odds ratios for appendicitis given appendiceal diameter, compressibility, hyperemia, free fluid, and focal or diffuse tenderness. The US score was then combined with the Alvarado score. Final diagnosis of appendicitis was assigned by pathology reports. Three hundred patients who underwent US as initial imaging were identified. Thirty-two patients with evident nonappendiceal pathology on US were excluded. In 114 (38%), the appendix was not visualized and partially visualized in 36 (12%). Fifty-seven (21.3%) had an appendectomy with 1 (1.7%) negative. Six nonvisualized appendicies underwent appendectomy, with no negative cases. Sensitivity and specificity for the sonographic score were 86% and 90%, respectively, at a score of 1.5. The combined score demonstrated 98% sensitivity and 82% specificity at 6.5, and 95% sensitivity, and 87% specificity at a score of 7.5. Sensitivity and specificity were confirmed by bootstrap resampling for validation. Area under receiver operating characteristic (ROC) curves for our new US score were similar to the ROC curve for the Alvarado score (91.9 and 91.1, p = 0.8). The combined US and Alvarado score yielded an area under the ROC curve of 97.1, significantly better than either score alone (p = 0.017 and p < 0.001, respectively). Our scoring system based entirely on US findings was highly sensitive and specific for appendicitis, and it significantly improved when combined with the Alvarado score. After prospective evaluation, the combined US-Alvarado score might replace the need for computed tomography imaging in a majority of patients. Diagnostic Test, Level III.
Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity
Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689
Robust detection of rare species using environmental DNA: the importance of primer specificity.
Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.
Koizumi, Mitsuru; Motegi, Kazuki; Koyama, Masamichi; Terauchi, Takashi; Yuasa, Takeshi; Yonese, Junji
2017-08-01
The computer-assisted diagnostic system for bone scintigraphy (BS) BONENAVI is used to evaluate skeletal metastasis. We investigated its diagnostic performance in prostate cancer patients with and without skeletal metastasis and searched for the problems. An artificial neural network (ANN) value was calculated in 226 prostate cancer patients (124 with skeletal metastasis and 101 without) using BS. Receiver operating characteristic curve analysis was performed and the sensitivity and specificity determined (cutoff ANN = 0.5). Patient's situation at the time of diagnosis of skeletal metastasis, computed tomography (CT) type, extent of disease (EOD), and BS uptake grade were analyzed. False-negative and false-positive results were recorded. BONENAVI showed 82% (102/124) of sensitivity and 83% (84/101) specificity for metastasis detection. There were no significant differences among CT types, although low EOD and faint BS uptake were associated with low ANN values and low sensitivity. Patients showed lower sensitivity during the follow-up period than staging work-up. False-negative lesions were often located in the pelvis or adjacent to it. They comprised not only solitary, faint BS lesions but also overlaying to urinary excretion. BONENAVI with BS has good sensitivity and specificity for detecting prostate cancer's osseous metastasis. Low EOD and faint BS uptake are associated with low sensitivity but not the CT type. Prostate cancer patients likely to have false-negative results during the follow-up period had a solitary lesion in the pelvis with faint BS uptake or lesions overlaying to urinary excretion.
Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B
2012-09-01
Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.
Cox, Marsha E.; DiNello, Robert K.; Geisberg, Mark; Abbott, April; Roberts, Pacita L.; Hooton, Thomas M.
2015-01-01
Urinary tract infections (UTIs) are frequently encountered in clinical practice and most commonly caused by Escherichia coli and other Gram-negative uropathogens. We tested RapidBac, a rapid immunoassay for bacteriuria developed by Silver Lake Research Corporation (SLRC), compared with standard bacterial culture using 966 clean-catch urine specimens submitted to a clinical microbiology laboratory in an urban academic medical center. RapidBac was performed in accordance with instructions, providing a positive or negative result in 20 min. RapidBac identified as positive 245/285 (sensitivity 86%) samples with significant bacteriuria, defined as the presence of a Gram-negative uropathogen or Staphylococcus saprophyticus at ≥103 CFU/ml. The sensitivities for Gram-negative bacteriuria at ≥104 CFU/ml and ≥105 CFU/ml were 96% and 99%, respectively. The specificity of the test, detecting the absence of significant bacteriuria, was 94%. The sensitivity and specificity of RapidBac were similar on samples from inpatient and outpatient settings, from male and female patients, and across age groups from 18 to 89 years old, although specificity was higher in men (100%) compared with that in women (92%). The RapidBac test for bacteriuria may be effective as an aid in the point-of-care diagnosis of UTIs especially in emergency and primary care settings. PMID:26063858
Singh, Binit Kumar; Sharma, Surendra K; Sharma, Rohini; Sreenivas, Vishnubhatla; Myneedu, Vithal P; Kohli, Mikashmi; Bhasin, Dinkar; Sarin, Sanjay
2017-01-01
To evaluate the performance of Genotype MTBDRplus VER 2.0 in the diagnosis of Mycobacterium tuberculosis (MTB) in sputum smear-negative pulmonary TB cases. A total of 572 Ziehl-Neelsen sputum smear-negative samples were selected and subjected to line probe assay (Genotype MTBDRplus VER 2.0), and culture in mycobacterial growth indicator tube (MGIT-960). Immunochromatographic test was used to confirm the MTB-complex (MTBC) in culture-positive samples and phenotypic drug-susceptibility testing was done using MGIT-960. The line probe assay was able to diagnose MTBC in 38.2% (213/558) of specimens after excluding 14 nontuberculous mycobacteria. Sensitivity and specificity of the assay were 68.4% and 89.3% respectively, considering MGIT-960 culture as gold standard after excluding contaminated and invalid results. On comparing with composite reference standard, the assay had 71.5% sensitivity and 100% specificity in the diagnosis of tuberculosis. The sensitivity and specificity for detecting resistance to rifampicin (RMP) were 100% and 99.24% respectively and for resistance to isoniazid (INH) were 97.62% and 98.55%, respectively. Genotype MTBDRplus VER 2.0 is a rapid and precise diagnostic tool for detection of MTB in sputum smear-negative samples. It also facilitates accurate diagnosis of RMP and INH resistance within turn around-time.
Development of a Pediatric Ebola Predictive Score, Sierra Leone1.
Fitzgerald, Felicity; Wing, Kevin; Naveed, Asad; Gbessay, Musa; Ross, J C G; Checchi, Francesco; Youkee, Daniel; Jalloh, Mohamed Boie; Baion, David E; Mustapha, Ayeshatu; Jah, Hawanatu; Lako, Sandra; Oza, Shefali; Boufkhed, Sabah; Feury, Reynold; Bielicki, Julia; Williamson, Elizabeth; Gibb, Diana M; Klein, Nigel; Sahr, Foday; Yeung, Shunmay
2018-02-01
We compared children who were positive for Ebola virus disease (EVD) with those who were negative to derive a pediatric EVD predictor (PEP) score. We collected data on all children <13 years of age admitted to 11 Ebola holding units in Sierra Leone during August 2014-March 2015 and performed multivariable logistic regression. Among 1,054 children, 309 (29%) were EVD positive and 697 (66%) EVD negative, with 48 (5%) missing. Contact history, conjunctivitis, and age were the strongest positive predictors for EVD. The PEP score had an area under receiver operating characteristics curve of 0.80. A PEP score of 7/10 was 92% specific and 44% sensitive; 3/10 was 30% specific, 94% sensitive. The PEP score could correctly classify 79%-90% of children and could be used to facilitate triage into risk categories, depending on the sensitivity or specificity required.
Shuaib, Abdullah; Shuaib, Ali; Fakhra, Zainab; Marafi, Bader; Alsharaf, Khalid; Behbehani, Abdullah
2017-01-01
Acute appendicitis is the most common surgical condition presented in emergency departments worldwide. Clinical scoring systems, such as the Alvarado and modified Alvarado scoring systems, were developed with the goal of reducing the negative appendectomy rate to 5%-10%. The Raja Isteri Pengiran Anak Saleha Appendicitis (RIPASA) scoring system was established in 2008 specifically for Asian populations. The aim of this study was to compare the modified Alvarado with the RIPASA scoring system in Kuwait population. This study included 180 patients who underwent appendectomies and were documented as having "acute appendicitis" or "abdominal pain" in the operating theatre logbook (unit B) from November 2014 to March 2016. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), diagnostic accuracy, predicted negative appendectomy and receiver operating characteristic (ROC) curve of the modified Alvarado and RIPASA scoring systems were derived using SPSS statistical software. A total of 136 patients were included in this study according to our criteria. The cut-off threshold point of the modified Alvarado score was set at 7.0, which yielded a sensitivity of 82.8% and a specificity of 56%. The PPV was 89.3% and the NPV was 42.4%. The cut-off threshold point of the RIPASA score was set at 7.5, which yielded a 94.5% sensitivity and an 88% specificity. The PPV was 97.2% and the NPV was 78.5%. The predicted negative appendectomy rates were 10.7% and 2.2% for the modified Alvarado and RIPASA scoring systems, respectively. The negative appendectomy rate decreased significantly, from 18.4% to 10.7% for the modified Alvarado, and to 2.2% for the RIPASA scoring system, which was a significant difference (P<0.001) for both scoring systems. Based on the results of this study, the RIPASA score is a simple scoring system with better sensitivity and specificity than the modified Alvarado scoring system in Asian populations. It consists of 14 clinical parameters that can be obtained from a good patient history, clinical examination and laboratory investigations. The RIPASA scoring system is more accurate and specific than the modified Alvarado scoring system for Kuwait population.
El-sayed, Dena; Grotts, Jonathan; Golgert, William A.; Sugar, Alan M.
2014-01-01
Background It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Methods Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18–65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m2, admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. Results The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Conclusions Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75. PMID:25734138
El-Sayed, Dena; Grotts, Jonathan; Golgert, William A; Sugar, Alan M
2014-09-01
It is unclear whether procalcitonin is an accurate predictor of bacterial infections in patients with renal impairment, although it is used as a biomarker for early diagnosis of sepsis. We determined the sensitivity, specificity, positive and negative predictive values, accuracy and best predictive value of procalcitonin for predicting bacterial infection in adult patients with severe renal impairment. Retrospective study at a single-center community teaching hospital involving 473 patients, ages 18-65, with Modification of Diet in Renal Disease eGFR ≤30 ml/min per 1.73 m(2), admitted between January 2009 and June 2012, with 660 independent hospital visits. A positive or negative culture (blood or identifiable focus of infection) was paired to the highest procalcitonin result performed 48 hours before or after collecting the culture. The sensitivity and specificity to predict bacterial infection, using a procalcitonin level threshold of 0.5 ng/mL, was 0.80 and 0.35 respectively. When isolating for presence of bacteremia, the sensitivity and specificity were 0.89 and 0.35 respectively. An equation adjusting for optimum thresholds of procalcitonin levels for predicting bacterial infection at different levels of eGFR had a sensitivity and specificity of 0.55 and 0.80 respectively. Procalcitonin is not a reliably sensitive or specific predictor of bacterial infection in patients with renal impairment when using a single threshold. Perhaps two thresholds should be employed, where below the lower threshold (i.e. 0.5 ng/mL) bacterial infection is unlikely with a sensitivity of 0.80, and above the higher threshold (i.e. 3.2 ng/mL) bacterial infection is very likely with a specificity of 0.75.
Detection of Bacteriuria by Canine Olfaction
Maurer, Maureen; McCulloch, Michael; Willey, Angel M.; Hirsch, Wendi; Dewey, Danielle
2016-01-01
Background. Urinary tract infections (UTIs) are a significant medical problem , particularly for patients with neurological conditions and the elderly. Detection is often difficult in these patients, resulting in delayed diagnoses and more serious infections such as pyelonephritis and life-threatening sepsis. Many patients have a higher risk of UTIs because of impaired bladder function, catheterization, and lack of symptoms. Urinary tract infections are the most common nosocomial infection; however, better strategies are needed to improve early detection of the disease. Methods. In this double-blinded, case-control, validation study, we obtained fresh urine samples daily in a consecutive case series over a period of 16 weeks. Dogs were trained to distinguish urine samples that were culture-positive for bacteriuria from those of culture-negative controls, using reward-based clicker and treat methods. Results. Samples were obtained from 687 individuals (from 3 months to 92 years of age; 86% female and 14% male; 34% culture-positive and 66% culture-negative controls). Dogs detected urine samples positive for 100 000 colony-forming units/mL Escherichia coli (N = 250 trials; sensitivity 99.6%, specificity 91.5%). Dilution of E coli urine with distilled water did not affect accuracy at 1% (sensitivity 100%, specificity 91.1%) or 0.1% (sensitivity 100%, specificity 93.6%) concentration. Diagnostic accuracy was similar to Enterococcus (n = 50; sensitivity 100%, specificity 93.9%), Klebsiella (n = 50; sensitivity 100%, specificity 95.1%), and Staphylococcus aureus (n = 50; sensitivity 100%, specificity 96.3%). All dogs performed with similarly high accuracy: overall sensitivity was at or near 100%, and specificity was above 90%. Conclusions. Canine scent detection is an accurate and feasible method for detection of bacteriuria. PMID:27186578
ERIC Educational Resources Information Center
Weems, Carl F.; Costa, Natalie M.; Watts, Sarah E.; Taylor, Leslie K.; Cannon, Melinda F.
2007-01-01
This study examined the interrelations among negative cognitive errors, anxiety sensitivity, and anxiety control beliefs and explored their unique and specific associations with anxiety symptoms in a community sample of youth. Existing research has suggested that these constructs are related to childhood anxiety disorder symptoms; however,…
Bruner, L H; Carr, G J; Harbell, J W; Curren, R D
2002-06-01
An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.
Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich
2014-12-18
In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.
Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S
2015-04-01
Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Pires, Frederico Ribeiro; Franco, Andréia Christine Bonotto Farias; Gilio, Alfredo Elias; Troster, Eduardo Juan
2017-01-01
ABSTRACT Objective: To evaluate Bacterial Meningitis Score (BMS) on its own and in association with Cerebrospinal Fluid (CSF) lactate dosage in order to distinguish bacterial from aseptic meningitis. Methods: Children diagnosed with meningitis at a tertiary hospital between January/2011 and December/2014 were selected. All data were obtained upon admission. BMS was applied and included: CSF Gram staining (2 points); CSF neutrophil count ≥1,000 cells/mm3 (1 point); CSF protein ≥80 mg/dL (1 point); peripheral blood neutrophil count ≥10,000 cells/mm3 (1 point) and seizures upon/before arrival (1 point). Cutoff value for CSF lactate was ≥30 mg/dL. Sensitivity, specificity and negative predictive value of several BMS cutoffs and BMS associated with high CSF lactate were evaluated for prediction of bacterial meningitis. Results: Among 439 eligible patients, 94 did not have all data available to complete the score, and 345 patients were included: 7 in bacterial meningitis group and 338 in aseptic meningitis group. As predictive factors of bacterial meningitis, BMS ≥1 had 100% sensitivity (95%CI 47.3-100), 64.2% specificity (58.8-100) and 100% negative predictive value (97.5-100); BMS ≥2 or BMS ≥1 associated with high CSF lactate also showed 100% sensitivity (47.3-100); but 98.5% specificity (96.6-99.5) and 100% negative predictive value (98.3-100). Conclusions: 2 point BMS in association with CSF lactate dosage had the same sensitivity and negative predictive value, with increased specificity for diagnosis of bacterial meningitis when compared with 1-point BMS. PMID:29185620
Hamilton, R G; Adkinson, N F
1996-11-01
Nonammoniated latex, ammoniated latex, and rubber glove extracts are the only sources of natural rubber (Hevea brasiliensis) latex that have potential for use as skin testing reagents in the diagnosis of latex allergy. Their diagnostic sensitivity and specificity as skin test reagents are unknown. We conducted a phase 1/2 clinical study to examine the safety and diagnostic accuracy (sensitivity and specificity) of nonammoniated latex, ammoniated latex, and rubber glove extracts as skin test extracts to identify the most efficacious source material for future skin test reagent development. Twenty-four adults not allergic to latex, 19 adults with hand dermatitis or pruritus, and 59 adults with a latex allergy were identified by clinical history. All provided blood and then received puncture skin tests and intradermal skin tests with nonammoniated latex, ammoniated latex, and rubber glove extracts from Malaysian H. brasiliensis latex by use of sequential titration. A glove provocation test and IgE anti-latex RAST were used to clarify positive history-negative skin test response and negative history-positive skin test response mismatches. All three extracts were biologically safe and sterile. After normalization to 1 mg/ml of total protein, all three extracts produced equivalent diagnostic sensitivity and specificity in puncture skin tests and intradermal skin tests at various extract concentrations. Optimal diagnostic accuracy was safely achieved at 100 micrograms/ml for intradermal skin tests (e.g., nonammoniated latex: puncture skin test sensitivity 96%, specificity 100%; intradermal skin test sensitivity 93%, specificity 96%). The presence of IgE antibody in skin was highly correlated with IgE anti-latex in serum (nonammoniated latex: r = 0.98, p < 0.001; ammoniated latex: r = 0.94, p < 0.001; rubber glove extract: r = 0.96, p < 0.001). All five available subjects with a positive history, negative skin test response, and absence of IgE antibody in serum had a negative glove provocation test response, indicating no clinical evidence of latex allergy. No systemic or large local allergic reactions were observed with puncture skin tests or intradermal skin tests. Equivalent diagnostic sensitivity and specificity were observed with the nonammoniated latex, ammoniated latex, and rubber glove extract skin test reagents after normalization for total protein; nonammoniated latex may be considered the reagent of choice on the basis of practical quality control and reproducibility considerations.
[Primary cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María
2015-01-01
Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Should gram stains have a role in diagnosing hip arthroplasty infections?
Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A
2010-09-01
The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
Olatunji, Bunmi O; Deacon, Brett
2008-01-01
This study examined the specificity of disgust sensitivity in predicting fear and disgust responses to exposure to a spider. Participants high (n=22) and low (n=28) in spider fear completed self-report measures of disgust sensitivity, contamination fear, anxiety, and negative affect. They then participated in a behavioral avoidance task (BAT) in which they were briefly exposed to a realistic-looking, but fake, tarantula. Results revealed that disgust sensitivity was associated with fear and disgust responding to the BAT. The association between disgust sensitivity and disgust responding to the BAT remained significant after controlling for gender, spider fear group membership, contamination fear, anxiety, and negative affect. However, the association between disgust sensitivity and fear responding to the BAT was only marginally significant after controlling for the same variables. Contamination fear was also strongly related to fear and disgust responding to the BAT. However, this relationship was fully mediated by disgust sensitivity. These findings indicate that disgust sensitivity has a unique association with aversive responding to spiders. The implications of these findings for better understanding the complex role of fear and disgust as they related to disgust sensitivity in spider phobia are discussed.
Wang, Fei; He, Bei
2013-01-01
To investigate the role of endotracheal aspirate (EA) culture in the diagnosis and antibiotic management in ventilator-associated pneumonia (VAP). We searched CNKI, Wanfang, PUBMED and EMBASE databases published from January 1990 to December 2011, to find relevant literatures on VAP microbiological diagnostic techniques including EA and bronchoalveolar lavage (BALF). The following key words were used: ventilator associated pneumonia, diagnosis and adult. Meta-analysis was performed and the sensitivity and specificity of EA on VAP diagnosis were calculated. Our literature search identified 1665 potential articles, 8 of which fulfilled our selection criteria including 561 patients with paired cultures. Using BALF quantitative culture as reference standard, the sensitivity and specificity of EA were 72% and 71%. When considering quantitative culture of EA only, the sensitivity and specificity improved to 90% and 65%, while the positive and the negative predictive values were 68% and 89% respectively. However, the sensitivity and specificity of semi-quantitative culture of EA were only 50% and 80%, with a positive predictive value of 77% and a negative predictive value of 58% respectively. EA culture had relatively poor sensitivity and specificity, although quantitative culture of EA only could improve the sensitivity. Initiating therapy on the basis of EA quantitative culture may still result in excessive antibiotic usage. Our data suggested that EA could provide some information for clinical decision but could not replace the role of BALF quantitative culture in VAP diagnosis.
Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura
2010-03-01
This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.
NASA Astrophysics Data System (ADS)
Petruzzi, Massimo; Lucchese, Alberta; Nardi, Gianna Maria; Lauritano, Dorina; Favia, Gianfranco; Serpico, Rosario; Grassi, Felice Roberto
2014-07-01
The objective was to compare toluidine blue (TB) and autofluorescence (AF) for the detection of oral dysplasia and squamous cell carcinoma (OSCC) in clinically suspicious lesions according to conventional examination. Fifty-six clinically suspicious lesions were subjected to AF and TB examination. Data were compared using two different scenarios: in the first, mild dysplasia was considered as positive, while in the second, it was considered as negative. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), accuracy, and concordance were calculated. AF sensitivity and specificity were 70.0 and 57.7%, respectively, while TB showed a sensitivity of 80% and a specificity of 61.5%. The sensitivity increased in the second scenario in both AF (76.5%) and TB (88.2%). The specificity decreased in AF and TB, showing the same value (51.3%). PPV was higher in TB than in AF (70.6 versus 65.6%) and similarly for NPV (72.7 versus 62.5%). In the second scenario, TB PPV was 44.1% and NPV was 90.9% AF PPV was 40.6% and NPV was 83.3%. TB showed greater accuracy than AF in the first scenario (62.5 versus 58.9%). AF and TB are both sensitive but not specific in OSCC and dysplasia diagnosis.
Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S
2012-02-15
Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.
Molina-Torres, María-José; Crespo, María-del-Mar Seguí; Francés, Ana Tauste; Lacarra, Blanca Lumbreras; Ronda-Pérez, Elena
2016-01-01
Objective: To compare the diagnostic accuracy of two vision screeners by a visual examination performed by an optometrist (gold standard) and to evaluate the concordance between both screeners and between each screener and the gold standard. Methods: This was a cross-sectional study that included computer workers who attended a routine yearly health examination. The study included administrative office workers (n=91) aged 50.2±7.9 years (mean±standard deviation), 69.2% of whom were women and 68.1% of whom used video display terminals (VDT) for >4 h/day. The routine visual examination included monocular and binocular distance visual acuity (VA), distance and near lateral phoria (LP), stereo acuity (SA), and color vision. Tests were repeated with Optec 6500 (by Stereo Optical) and Visiotest (by Essilor) screeners. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and false positive and negative rates were calculated. Kappa coefficient (κ) was used to measure the concordance of the screeners and the gold standard. Results: The sensitivity and specificity for monocular VA were over 80% for both vision screeners; PPV was below 25%. Sensitivity and specificity were lower for SA (55%-70%), PPV was 50%, and NPV was 75% for both screeners. For distance LP, sensitivity and PPV were <10% in both cases. The screeners differed in their values for near LP: Optec 6500 had higher sensitivity (43.5%), PPV (37.0%), and NPV (79.7%); whereas the Visiotest had higher specificity (83.8%). For color vision, Visiotest showed low sensitivity, low PPV, and high specificity. Visiotest obtained false positive rates that were lower or similar to Optec 6500, and both screeners obtained false negative rates below 50%. Both screeners showed poor concordance (κ<0.40). Conclusions: A high value for NPV would qualify both screeners as acceptable alternatives for visual health surveillance when used as a screening tool; patients with positive test results should be referred to a specialist. PMID:27488039
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay. PMID:15634970
Xu, Benjin; Liu, Ling; Liu, Li; Li, Xinping; Li, Xiaofang; Wang, Xin
2012-11-01
Methicillin-resistant Staphylococcus aureus (MRSA) is a global health concern, which had been detected in food and food production animals. Conventional testing for detection of MRSA takes 3 to 5 d to yield complete information of the organism and its antibiotic sensitivity pattern. So, a rapid method is needed to diagnose and treat the MRSA infections. The present study focused on the development of a multiplex PCR assay for the rapid and sensitive detection of MRSA. The assay simultaneously detected 4 genes, namely, 16S rRNA of the Staphylococcus genus, femA of S. aureus, mecA that encodes methicillin resistance, and one internal control. It was rapid and yielded results within 4 h. The analytical sensitivity and specificity of the multiplex PCR assay was evaluated by comparing it with the conventional method. The analytical sensitivity of the multiplex PCR assay at the DNA level was 10 ng DNA. The analytical specificity was evaluated with 10 reference staphylococci strains and was 100%. The diagnostic evaluation of MRSA was carried out using 360 foodborne staphylococci isolates, and showed 99.1% of specificity, 96.4% of sensitivity, 97.5% of positive predictive value, and 97.3% of negative predictive value compared to the conventional method. The inclusion of an internal control in the multiplex PCR assay is important to exclude false-negative cases. This test can be used as an effective diagnostic and surveillance tool to investigate the spread and emergence of MRSA. © 2012 Institute of Food Technologists®
Mitchell, Rebecca; Thomas, Sunethra Devika; Langlois, Neil E I
2013-10-01
Biochemical analysis of glucose and ketones in the vitreous humour obtained at post-mortem examination is representative of the levels in the blood prior to death. Elevated levels can be indicative of conditions including diabetic ketoacidosis, which can be a cause for unexpected death. A rapid screening test for such conditions can be performed during the autopsy through urinalysis using test strips (urine 'dipstick' testing). The aim of this study was to assess the utility of urinalysis testing for post-mortem detection of derangements of glucose and ketone levels. The results of vitreous biochemical analysis and urinalysis were collated from 188 forensic autopsy cases. A vitreous glucose result of above 10 mmol/L was regarded as high. When this was compared to urinalysis results it was found that any urinalysis result above negative had a sensitivity of 0.83 and a specificity of 0.93. A vitreous ketone level of above 5 mmol/L was regarded as significantly elevated; a urinalysis result above negative had a sensitivity of 1, but a specificity of 0.12. Urinalysis ('dipstick' testing) for glucose has a good sensitivity and specificity for high vitreous glucose levels, which are regarded as indicative of pathological hyperglycaemia during life. It was found that urine testing for ketones either has an excellent sensitivity with low specificity or a poor sensitivity with a good specificity; however, this finding has to be viewed in the context of uncertainty of the biochemical level of significant ketosis.
Kanoto, Masafumi; Sugai, Yukio; Hosoya, Takaaki; Toyoguchi, Yuuki; Konno, Yoshihiro; Watarai, Fumika; Ito, Tsukasa; Watanabe, Tomoo; Kakehata, Seiji
2015-12-01
Cholesteatomas show high intensity in diffusion-weighted imaging (DWI). We performed fused thin slice non-echo planar imaging (EPI) DWI and magnetic resonance cisternography (FTS-nEPID) for cholesteatoma patients to increase the detectability of FTS-nEPID for cholesteatoma. The subjects are 77 consecutive patients who underwent FTS-nEPID as a preoperative study (mean age: 53.3±21.8, 47 men and 30 women). Otorhinolaryngologists performed the operations. We anatomically classified the middle ear into four portions. A radiologist evaluated the images for cholesteatoma and assessed the anatomical invasive range in four portions using only FTS-nEPID. We classified large cholesteatomas that invaded more than three portions and small ones that invaded less than two portions based on the results obtained from surgery, and calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). For all cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 71%, 70%, 94%, and 27%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 49%, 85%, 77%, and 64%, respectively. For large cholesteatomas with an existing diagnosis, the sensitivity was 86%. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 51%, 57%, 88%, and 18%, respectively. For small cholesteatomas with an existing diagnosis, the sensitivity, specificity, PPV, and NPV were 59%, 78%, 92%, and 30%, respectively. In anatomical evaluation, the sensitivity, specificity, PPV, and NPV were 40%, 85%, 60%, and 71%, respectively. FTS-nEPID may be useful for diagnosing cholesteatomas. Further research is needed for anatomical evaluation because there were many false-negative results. Copyright © 2015 Elsevier Inc. All rights reserved.
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valencia, Antoni; Prous, Josep; Mora, Oscar
As indicated in ICH M7 draft guidance, in silico predictive tools including statistically-based QSARs and expert analysis may be used as a computational assessment for bacterial mutagenicity for the qualification of impurities in pharmaceuticals. To address this need, we developed and validated a QSAR model to predict Salmonella t. mutagenicity (Ames assay outcome) of pharmaceutical impurities using Prous Institute's Symmetry℠, a new in silico solution for drug discovery and toxicity screening, and the Mold2 molecular descriptor package (FDA/NCTR). Data was sourced from public benchmark databases with known Ames assay mutagenicity outcomes for 7300 chemicals (57% mutagens). Of these data, 90%more » was used to train the model and the remaining 10% was set aside as a holdout set for validation. The model's applicability to drug impurities was tested using a FDA/CDER database of 951 structures, of which 94% were found within the model's applicability domain. The predictive performance of the model is acceptable for supporting regulatory decision-making with 84 ± 1% sensitivity, 81 ± 1% specificity, 83 ± 1% concordance and 79 ± 1% negative predictivity based on internal cross-validation, while the holdout dataset yielded 83% sensitivity, 77% specificity, 80% concordance and 78% negative predictivity. Given the importance of having confidence in negative predictions, an additional external validation of the model was also carried out, using marketed drugs known to be Ames-negative, and obtained 98% coverage and 81% specificity. Additionally, Ames mutagenicity data from FDA/CFSAN was used to create another data set of 1535 chemicals for external validation of the model, yielding 98% coverage, 73% sensitivity, 86% specificity, 81% concordance and 84% negative predictivity. - Highlights: • A new in silico QSAR model to predict Ames mutagenicity is described. • The model is extensively validated with chemicals from the FDA and the public domain. • Validation tests show desirable high sensitivity and high negative predictivity. • The model predicted 14 reportedly difficult to predict drug impurities with accuracy. • The model is suitable to support risk evaluation of potentially mutagenic compounds.« less
Performance of the dipstick screening test as a predictor of negative urine culture.
Marques, Alexandre Gimenes; Doi, André Mario; Pasternak, Jacyr; Damascena, Márcio Dos Santos; França, Carolina Nunes; Martino, Marinês Dalla Valle
2017-01-01
To investigate whether the urine dipstick screening test can be used to predict urine culture results. A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.
Speed, Traci J; Richards, Jessica M; Finan, Patrick H; Smith, Michael T
2017-07-01
Sex differences in clinical pain severity and response to experimental pain are commonly reported, with women generally showing greater vulnerability. Affect, including state (a single rating) and stable (average daily ratings over two weeks) positive affect and negative affect has also been found to impact pain sensitivity and severity, and research suggests that affect may modulate pain differentially as a function of sex. The current study aimed to examine sex as a moderator of the relationships between affect and pain-related outcomes among participants with knee osteoarthritis (KOA). One hundred and seventy-nine participants (59 men) with KOA completed electronic diaries assessing clinical pain, positive affect, and negative affect. A subset of participants (n=120) underwent quantitative sensory testing, from which a single index of central sensitization to pain was derived. We used multiple regression models to test for the interactive effects of sex and affect (positive versus negative and stable versus state) on pain-related outcomes. We used mixed effects models to test for the moderating effects of sex on the relationships between state affect and pain over time. Sex differences in affect and pain were identified, with men reporting significantly higher stable positive affect and lower central sensitization to pain indexed by quantitative sensory testing, as well as marginally lower KOA-specific clinical pain compared to women. Moreover, there was an interaction between stable positive affect and sex on KOA-specific clinical pain and average daily non-specific pain ratings. Post hoc analyses revealed that men showed trends towards an inverse relationship between stable positive affect and pain outcomes, while women showed no relationship between positive affect and pain. There was also a significant interaction between sex and stable negative affect and sex on KOA-specific pain such that men showed a significantly stronger positive relationship between stable negative affect and KOA-specific pain than women. Sex did not interact with state affect on pain outcomes. Findings suggest that men may be particularly sensitive to the effects of stable positive affect and negative affect on clinical pain. Future work with larger samples is needed in order to identify potential mechanisms driving the sex-specific effects of affect on pain. The current study provides novel data that suggesting that the association of positive affect, negative affect, and pain are different in men versus women with KOA. Further understanding of the difference in affective expression between men and women may lead to the development of novel therapeutic interventions and help to identify additional modifiable factors in the prevention and management of pain. Copyright © 2017 Scandinavian Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio
2014-01-01
To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.
Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn
2005-06-01
The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.
Horstkotte, M A; Knobloch, J K; Rohde, H; Mack, D
2001-10-01
The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 microg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.
Can hip abduction and external rotation discriminate sacroiliac joint pain?
Adhia, Divya Bharatkumar; Tumilty, Steve; Mani, Ramakrishnan; Milosavljevic, Stephan; Bussey, Melanie D
2016-02-01
The primary aim of the study is to determine if Hip Abduction and External Rotation (HABER) test is capable of reproducing familiar pain in individuals with low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive) when compared with LBP of Non-SIJ origin (SIJ-negative). If so, the secondary aim is to determine the diagnostic accuracy of HABER test against the reference standard of pain provocation tests, and to determine which increments of the HABER test has highest sensitivity and specificity for identifying SIJ-positive individuals. Single-blinded diagnostic accuracy study. Participants [n(122)] between ages of 18-50 y, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)], based on reference standard of pain provocation tests [≥3 positive tests = SIJ-positive]. Another musculoskeletal physiotherapist, blinded to clinical groups, evaluated participants for reproduction of familiar pain during each increment (10°, 20°, 30°, 40°, and 50°) of HABER test. The HABER test reproduced familiar pain in SIJ-positive individuals when compared with SIJ-negative individuals [p (0.001), R(2) (0.38), Exp(β) (5.95-10.32)], and demonstrated moderate level of sensitivity (67%-78%) and specificity (71%-72%) for identifying SIJ-positive individuals. Receiver operator curve analysis demonstrated that the HABER increments of ≥30° have the highest sensitivity (83%-100%) and specificity (52%-64%). The HABER test is capable of reproducing familiar pain in SIJ-positive LBP individuals and has moderate levels of sensitivity and specificity for identifying SIJ-positive LBP individuals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wsol, Agnieszka; Wydra, Wioletta; Chmielewski, Marek; Swiatowiec, Andrzej; Kuch, Marek
2017-01-01
A retrospective study was designed to investigate P-wave duration changes in exercise stress test (EST) for the prediction of angiographically documented substantial coronary artery disease (CAD). We analyzed 265 cases of patients, who underwent EST and subsequently coronary angiography. Analysis of P-wave duration was performed in leads II, V5 at rest, and in the recovery period. The sensitivity and specificity for the isolated ST-segment depression were only 31% and 76%, respectively. The combination of ST-depression with other exercise-induced clinical and electrocardio-graphic abnormalities (chest pain, ventricular arrhythmia, hypotension, left bundle branch block) was characterized by 41% sensitivity and 69% specificity. The combination of abnormal recovery P-wave duration (≥ 120 ms) with ST-depression and other exercise-induced abnormalities had 83% sensitivity but only 20% specificity. Combined analysis of increased delta P-wave duration, ST-depression and other exercise-induced abnormalities had 69% sensitivity and 42% specificity. Sensitivity and specificity of the increase in delta P-wave duration for left CAD was 69% and 47%, respectively, and for 3-vessel CAD 70% and 50%, respectively. The presence of arterial hypertension negatively influenced the prog-nostic value of P-wave changes in the stress test. The results of the study show that an addition of P-wave duration changes assessment to ST-depression analysis and other exercise-induced abnormalities increase sensitivity of EST, especially for left CAD and 3-vessel coronary disease. We have also provided evidence for the negative influence of the presence of arterial hypertension on the predictive value of P-wave changes in the stress test. (Cardiol J 2017; 24, 2: 159-166).
Bagut, Elena Tatiana; Cambier, Ludivine; Heinen, Marie-Pierre; Cozma, Vasile; Monod, Michel; Mignon, Bernard
2013-08-01
The aim of this study was to develop an in-house enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of ringworm infection in cattle. We used available recombinant forms of Trichophyton rubrum dipeptidyl peptidase V (TruDppV) and T. rubrum leucin aminopeptidase 2 (TruLap2), which are 98% identical to Trichophyton verrucosum orthologues. Field serum samples from 135 cattle with ringworm infection, as confirmed by direct microscopy, fluorescence microscopy, and PCR, and from 55 cattle without any apparent skin lesions or history of ringworm infection that served as negative controls were used. Sensitivities, specificities, and positive and negative predictive values were determined to evaluate the diagnostic value of our ELISA. Overall, the ELISAs based on recombinant TruDppV and TruLap2 discriminated well between infected animals and healthy controls. Highly significant differences (P < 0.0001, Mann-Whitney U test) were noted between optical density values obtained when sera from infected versus control cattle were tested. The ELISA developed for the detection of specific antibodies against DppV gave 89.6% sensitivity, 92.7% specificity, a 96.8% positive predictive value, and a 78.4% negative predictive value. The recombinant TruLap2-based ELISA displayed 88.1% sensitivity, 90.9% specificity, a 95.9% positive predictive value, and a 75.7% negative predictive value. To the best of our knowledge, this is the first ELISA based on recombinant antigens for assessing immune responses to ringworm infection in cattle; it is particularly suitable for epidemiological studies and also for the evaluation of vaccines and/or vaccination procedures.
Kogan, Dmitriy; Jain, Arad; Kimbro, Shawn; Gutierrez, Guillermo; Jain, Vivek
2016-08-01
Respiratory inductance plethysmography (RIP) is a tool used during a polysomnogram (PSG), which serves as a surrogate of respiratory effort and can help detect inspiratory air-flow limitation. We hypothesize that RIP can improve the sensitivity and specificity of scoring hypopneas when compared with both the recommended and acceptable criteria of the American Academy of Sleep Medicine. We retrospectively analyzed a cohort of 12 subjects who had no obstructive sleep apnea (OSA) or mild OSA on PSG when scored by the American Academy of Sleep Medicine acceptable criteria for hypopneas but had high clinical suspicion for a diagnosis of OSA. These subjects were rescored using the American Academy of Sleep Medicine recommended criteria as well as RIP. Hypopnea was scored when there was a 50% decrease in the amplitude of the RIP sum channel (which combined input from chest and abdominal belts). OSA was diagnosed if the subjects had >5 respiratory events/h of sleep. The subject's response to CPAP was assessed by using a short questionnaire called the post-PSG sleep assessment. which evaluated subjective sleep quality. A positive response was considered an improvement in the post-PSG sleep assessment score after CPAP use. When scored using the American Academy of Sleep Medicine acceptable criteria, 10 subjects had a negative study, and 2 subjects had mild OSA for a sensitivity of 11% and specificity of 50%. When scored using the recommended criteria, 10 subjects had OSA, and 2 were negative, for a sensitivity of 78% and specificity of 70%. By RIP scoring, all 12 subjects had >5 respiratory events/h for a sensitivity of 100% and specificity of 75%. This small retrospective pilot study showed improved sensitivity and specificity when scoring hypopneas by RIP sum channel. Copyright © 2016 by Daedalus Enterprises.
Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.
Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein
2016-06-01
Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.
Shirah, Bader Hamza; Shirah, Hamza Asaad; Alhaidari, Wael Awad; Elraghi, Mohamed Ali; Chughtai, Mohammad Azam
2017-01-01
The diagnosis of acute appendicitis is mainly clinical and is correct in about 80% of patients, but 20-33% present with atypical findings, which resulted in a negative appendectomy rate of 20-30%. The graded compression ultrasound method in the diagnosis of acute appendicitis was reported with a sensitivity of 89%, and specificity of 95%. In this study, we aim to evaluate the graded compression ultrasonography in the diagnosis of acute appendicitis, its influence on the clinical judgment to operate, and its role in lowering the negative appendectomy rate. 1073 patients treated surgically for acute appendicitis between January 2005 and December 2014 were reviewed. Ultrasound findings, histopathological diagnosis, and positive or negative appendectomy rates were analyzed. 647 (60.3%) patients were males and 426 (39.7%) females. The mean age was 26.5 years. Positive ultrasound findings were recorded in 892 (83.13%), while negative findings were recorded in 181 (16.87%). Positive appendectomy was recorded in 983 (91.6%), while negative appendectomy was recorded in 90 (8.4%). The sensitivity was 83%, specificity was 100%, and the rate of negative appendectomy was 8.39%. Graded compression technique of ultrasound is a useful modality, in addition to the clinical judgment of the surgeon and clinical findings, in detecting true positive cases of acute appendicitis, and thus reducing the negative appendectomy rate. Values of 100% specificity, and 8.4% negative appendectomy rate, or better, could be achieved, when an experienced surgeon and a professional radiologist collaborate in the diagnosis of acute appendicitis.
Sensitivity, specificity, positive and negative predictive values: diagnosing purple mange.
Collier, Jill; Huebscher, Roxana
2010-04-01
To shed light on several epidemiological terms for better understanding of diagnostic testing measures by using a mythical condition, "purple mange." Scientific literature related to epidemiology and statistical tests. Nurse practitioners (NPs) use the concepts of sensitivity (SEN), specificity (SPEC), positive predictive value (PPV), and negative predictive value (NPV) daily in primary care and specialty areas. In addition, PPV and NPV vary with the prevalence of a condition. At times, NPs misunderstand the meaning of these terms. In order to develop appropriate treatment plans, an understanding of the concepts of SEN, SPEC, PPV, and NPV is important for interpreting test results. The authors have used this mythical condition purple mange as a teaching tool for NP students.
A systematic review of screening questionnaires for childhood lead poisoning.
Ossiander, Eric M
2013-01-01
The Centers for Disease Control and Prevention encourages the use of risk factor questionnaires to screen children for lead poisoning. A majority of state health departments have formal lead screening guidelines that recommend health care providers use questionnaires. We conducted a systematic review to evaluate the ability of lead screening questionnaires to predict lead poisoning risk among children. Articles that reported the evaluation of a predesigned lead screening questionnaire were obtained by searching Medline/PubMed and by examining references of articles obtained through the online search. From each evaluation, we abstracted the number of children that were true positive, false positive, true negative, and false negative, according to the results of the screening questionnaire and the follow-up blood lead test. From these data, we calculated specificity and sensitivity of the questionnaire for each evaluation. Twenty articles met the inclusion criteria: these included 28 separate questionnaire evaluations. Among 17 evaluations of the 1991 Centers for Disease Control and Prevention questionnaire, sensitivity ranged from 0.25 to 0.87, specificity from 0.31 to 0.80, and accuracy (sum of sensitivity and specificity) from 0.74 to 1.39. The pooled mean estimates for this questionnaire were sensitivity 0.61 (95% confidence interval: 0.53-0.68); specificity 0.52 (0.45-0.60); accuracy 1.12 (1.06-1.18). Among 11 evaluations of all other questionnaires, sensitivity ranged from 0.43 to 0.90, specificity from 0.17 to 0.66, and accuracy from 0.94 to 1.27. For these questionnaires, the pooled mean estimates were sensitivity 0.76 (0.68-0.85), specificity 0.41 (0.33-0.49), and accuracy 1.12 (1.06-1.18). Lead screening questionnaires showed a wide range of sensitivity and specificity and performed little better than chance at predicting lead poisoning risk among children.
de Gier, Camilla; Pickering, Janessa L.; Richmond, Peter C.; Thornton, Ruth B.
2016-01-01
We have developed a specific Haemophilus influenzae quantitative PCR (qPCR) that also identifies fucose-negative and protein D-negative strains. Analysis of 100 H. influenzae isolates, 28 Haemophilus haemolyticus isolates, and 14 other bacterial species revealed 100% sensitivity (95% confidence interval [CI], 96% to 100%) and 100% specificity (95% CI, 92% to 100%) for this assay. The evaluation of 80 clinical specimens demonstrated a strong correlation between semiquantitative culture and the qPCR (P < 0.001). PMID:27335148
Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A
1998-01-01
The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.
Palumbo, Barbara; Sivolella, Silvio; Palumbo, Isabella; Buresta, Tommaso; Radicchia, Valentina; Fravolini, Mario L; Ferretti, Francesca; Bellavita, Rita; Mearini, Luigi; Scialpi, Michele; Aristei, Cynthia; Pelliccia, Gianfranco
2016-12-01
Patients with suspected recurrence of prostate cancer undergoing [18F]fluoromethyl choline ([18F]FCH) PET/CT were retrospectively evaluated to investigate the influence of hormonal therapy (HT) in [18F]FCH uptake. [18F]FCH PET/CT was performed in 102 surgically treated patients with suspected recurrence (PSA increase >0.2 ng/mL) of prostate cancer, divided in two groups: under HT (N.=54) and without HT (N.=48) at the time of PET scanning. PET/CT was carried out by an integrated system (Biograph 6, CTI/Siemens, Knoxville, TN, USA) intravenously by administering 4.1 MBq/kg of [18F]FCH to each patient; images were acquired 60 minutes later. On the total number of patients, 66 were found to be true positives (TP), 9 false positives (FP), 5 false negatives (FN) and 22 true negatives (TN), sensitivity to [18F]FCH PET/CT was 93%, specificity 71%, accuracy 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 81%. In the 54 patients under HT, 38 were TP, 6 FP, 3 FN and 7 TN, sensitivity was 93%, specificity 54%, accuracy 83%, PPV 86% and NPV was 70%. In the 48 patients receiving no HT, 28 were TP, 3 FP, 2 FN and 15 TN, sensitivity was 93%, specificity 83%, accuracy 90%, PPV 90% and NPV 88%. A χ2 test showed that sensitivity, accuracy and PPV did not differ among patients with and without HT, while specificity and NPV were significantly lower (P<0.001) in HT treated patients. Sensitivity, accuracy and PPV were similar in patients with and without HT. Specificity and NPV were reduced in patients under HT, but further data are necessary to support if this reduction is casual or related to therapy and it could be confirmed in a larger series of patients.
Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M
2018-01-01
Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.
Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard
2011-10-10
Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Fonseca Alonso, Barbara; Nixdorf, Donald R; Shueb, Sarah S; John, Mike T; Law, Alan S; Durham, Justin
2017-01-01
Two groups of patients with orofacial pains that are clinically important to distinguish from each other are patients with odontogenic pain and temporomandibular disorder (TMD) pain. The aim of this study was to determine the sensitivity and specificity of 2 screening instruments in distinguishing between patients with these types of pain. A convenience sample of patients seeking care at an endodontic clinic and an orofacial pain clinic were recruited. The 14-item dental pain questionnaire (DePaQ) was used to screen for odontogenic pain and the 6-item TMD screener was used to screen for TMD pain. Sensitivity and specificity calculations with 95% confidence intervals (CIs) were performed for both instruments, and thresholds/acceptability/performance was assessed using published guidelines. Thirty-four patients with odontogenic pain and 37 patients with TMD pain were included in this study. The sensitivity of the DePaQ was 0.85 (95% CI, 0.69-0.95), and specificity was 0.11 (95% CI, 0.03-0.25). The sensitivity of the TMD screener was 0.92 (95% CI, 0.78-0.98), and specificity was 0.59 (95% CI, 0.41-0.75). The point estimates, a single value used to estimate the population parameter, for both the DePaQ and TMD screener were "acceptable" in identifying patients who had the pain condition in question (ie, sensitivity), whereas the point estimate for appropriately identifying patients who did not have the pain condition when they did not have it (ie, specificity) was "nonacceptable" for both. The DePaQ and the TMD screener lack diagnostic accuracy for differentiating TMD from odontogenic tooth pain without adjunctive (clinical) investigation(s) or examination. However, the TMD screener has high sensitivity for identifying true positives (ie, TMD pain) and would therefore be useful as a screening instrument when one can definitively exclude odontogenic etiology for pain on clinical and radiographic grounds, for instance in endodontic practices. In this study, the negative predictive value was also high in the TMD screener, and, therefore, we can trust a negative result (ie, when the TMD screener is negative, we can be fairly certain the pain diagnosis is not TMD and rule out TMD). Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Cotte, L; Drouet, E; Bissuel, F; Denoyel, G A; Trepo, C
1993-08-01
In order to assess the value of human cytomegalovirus (HCMV) DNA amplification of gastrointestinal biopsies, we studied 57 human immunodeficiency virus-infected patients with and without gastrointestinal HCMV diseases. After DNA extraction, a 406-bp fragment from the unique short region of the HCMV genome was amplified by 35 cycles of polymerase chain reaction (PCR) and semiquantified from 80 to 80,000 HCMV genomic copies. Among 12 non-AIDS patients, the PCR assay was negative for 11 of 12 duodenal and 8 of 8 colorectal samples. It was also negative for 28 of 31 duodenal and 12 of 15 colorectal samples from 31 AIDS patients without gastrointestinal HCMV diseases. Among 14 AIDS patients with gastrointestinal HCMV diseases, the PCR assay was positive for 12 of 12 patients with HCMV duodenitis and for 13 of 13 patients with HCMV colitis. Results were dichotomized between high and low HCMV-DNA copy numbers. For duodenitis, sensitivity was 92% and specificity was 100%. For colitis, sensitivity was 92% and specificity was 93%. Specificity and sensitivity were not influenced by shedding status for HCMV or by other gastrointestinal infections. HCMV DNA amplification of gastrointestinal biopsies is a sensitive and specific tool for the diagnosis of gastrointestinal HCMV diseases in AIDS patients.
Tarr, Gillian A M; Eickhoff, Jens C; Koepke, Ruth; Hopfensperger, Daniel J; Davis, Jeffrey P; Conway, James H
2013-07-15
Pertussis remains difficult to control. Imperfect sensitivity of diagnostic tests and lack of specific guidance regarding interpretation of negative test results among patients with compatible symptoms may contribute to its spread. In this study, we examined whether additional pertussis cases could be identified if persons with negative pertussis test results were routinely investigated. We conducted interviews among 250 subjects aged ≤18 years with pertussis polymerase chain reaction (PCR) results reported from 2 reference laboratories in Wisconsin during July-September 2010 to determine whether their illnesses met the Centers for Disease Control and Prevention's clinical case definition (CCD) for pertussis. PCR validity measures were calculated using the CCD as the standard for pertussis disease. Two Bayesian latent class models were used to adjust the validity measures for pertussis detectable by 1) culture alone and 2) culture and/or more sensitive measures such as serology. Among 190 PCR-negative subjects, 54 (28%) had illnesses meeting the CCD. In adjusted analyses, PCR sensitivity and the negative predictive value were 1) 94% and 99% and 2) 43% and 87% in the 2 types of models, respectively. The models suggested that public health follow-up of reported pertussis patients with PCR-negative results leads to the detection of more true pertussis cases than follow-up of PCR-positive persons alone. The results also suggest a need for a more specific pertussis CCD.
Pearson, Matthew R; Bravo, Adrian J; Kirouac, Megan; Witkiewitz, Katie
2017-02-01
To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n=1726) and COMBINE (n=1383). In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pearson, Matthew R.; Bravo, Adrian J.; Kirouac, Megan; Witkiewitz, Katie
2017-01-01
Background To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. Methods We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n = 1,726) and COMBINE (n = 1,383). Results In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. Conclusions These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. PMID:28038361
Bajaj, Ashish; Bhatia, Vinay; Dutt, Sarjana
2016-01-01
Introduction Tuberculosis remains one of the deadliest communicable diseases. There are number of tests available for the diagnosis of tuberculosis but conventional microscopy has low sensitivity and culture although gold standard, but takes longer time for positivity. On the other side, Nucleic acid amplification techniques due to its rapidity and sensitivity not only help in early diagnosis and management of tuberculosis especially in patients with high clinical suspicion like immunocompromised patients, history of contact with active tuberculosis patient etc., but also curtail the transmission of the disease. Aim To evaluate the sensitivity, specificity, positive predictive value and negative predictive value of Nucleic acid amplification assay (GeneXpert) using respiratory samples in patients with suspected pulmonary tuberculosis and compare with AFB smear microscopy (Ziehl Neelsen stain) and Acid Fast Bacilli (AFB) culture. Materials and Methods We retrospectively reviewed the respiratory samples of suspected pulmonary tuberculosis (including Bronchoalveolar lavage and sputum) of 170 patients from Jan 2015 to Nov 2015 for ZN stain, culture and GeneXpert (Xpert® MTB/Rif assay). The sensitivity, specificity, PPV and NPV of GeneXpert and ZN microscopy were calculated using Liquid culture of Mycobacterium tuberculosis as gold standard. Results A total of 170 patient samples were evaluated in final analysis. Of these, 14 samples were positive by all three methods used in our study. The overall sensitivity, specificity, PPV and NPV of GeneXpert were 86.8%, 93.1%, 78.5% and 96% respectively and for BAL sample, 81.4%, 93.4%, 73.3% and 95.7% respectively. The overall sensitivity and specificity of AFB smear microscopy were 22.2%, % and 78.5% respectively and for BAL sample 22.2% and 100% respectively. For AFB negative samples sensitivity and specificity were 79.1% and 93.1% respectively. Conclusion GeneXpert has a higher sensitivity than AFB smear microscopy in respiratory samples. GeneXpert can be a useful tool for early diagnosis of patients with high clinical suspicion of pulmonary tuberculosis. Positive GeneXpert, but culture negative results should be read cautiously and be well correlated with clinical and treatment history of the patient. The other major advantage of Gene Xpert is that it simultaneously detects Rifampicin resistance and especially beneficial in patient with MDR and HIV associated tuberculosis and should be studied further. PMID:27437212
Zhou, Zhiran; Zhang, Huitian; Lei, Yunxia
2016-10-01
To evaluate the diagnostic value of secreted frizzled-related protein 2 (SFRP2) gene promoter hypermethylation in stool for colorectal cancer (CRC). Open published diagnostic study of SFRP2 gene promoter hypermethylation in stool for CRC detection was electronic searched in the databases of PubMed, EMBASE, Cochrane Library, Web of Science, and China National Knowledge Infrastructure. The data of true positive, false positive false negative, and true negative identified by stool SFRP2 gene hypermethylation was extracted and pooled for diagnostic sensitivity, specificity, and summary receiver operating characteristic (SROC) curve. According to the inclusion and exclusion criteria, we finally included nine publications with 792 cases in the meta-analysis. Thus, the diagnostic sensitivity was aggregated through random effect model. The pooled sensitivity was 0.82 with the corresponding 95% confidence interval (95% CI) of 0.79-0.85; the pooled specificity and its corresponding 95% CI were 0.47 and 0.40-0.53 by the random effect model; we pooled the SROC curve by sensitivity versus specificity according to data published in the nine studies. The area under the SROC curve was 0.70 (95% CI: 0.65-0.73). SFRP2 gene promoter hypermethylation in stool can was a potential biomarker for CRC diagnosis with relative high sensitivity.
Intra-Operative Frozen Sections for Ovarian Tumors – A Tertiary Center Experience
Arshad, Nur Zaiti Md; Ng, Beng Kwang; Paiman, Noor Asmaliza Md; Mahdy, Zaleha Abdullah; Noor, Rushdan Mohd
2018-01-01
Background: Accuracy of diagnosis with intra-operative frozen sections is extremely important in the evaluation of ovarian tumors so that appropriate surgical procedures can be selected. Study design: All patients who with intra-operative frozen sections for ovarian masses in a tertiary center over nine years from June 2008 until April 2017 were reviewed. Frozen section diagnosis and final histopathological reports were compared. Main outcome measures: Sensitivity, specificity, positive and negative predictive values of intra-operative frozen section as compared to final histopathological results for ovarian tumors. Results: A total of 92 cases were recruited for final evaluation. The frozen section diagnoses were comparable with the final histopathological reports in 83.7% of cases. The sensitivity, specificity, positive predictive value and negative predictive value for benign and malignant ovarian tumors were 95.6%, 85.1%, 86.0% and 95.2% and 69.2%, 100%, 100% and 89.2% respectively. For borderline ovarian tumors, the sensitivity and specificity were 76.2% and 88.7%, respectively; the positive predictive value was 66.7% and the negative predictive value was 92.7%. Conclusion: The accuracy of intra-operative frozen section diagnoses for ovarian tumors is high and this approach remains a reliable option in assessing ovarian masses intra-operatively. PMID:29373916
El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro
2010-12-01
Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.
Drama-induced affect and pain sensitivity.
Zillmann, D; de Wied, M; King-Jablonski, C; Jenzowsky, S
1996-01-01
This study was conducted to examine the pain-ameliorating and pain-sensitizing effects of exposure to emotionally engaging drama. Specifically, the consequences for pain sensitivity of exposure to dramatic expositions differing in both excitatory and hedonic qualities were determined. Hedonically negative, neutral, and positive affective states were induced in male respondents by exposure to excerpts from cinematic drama. Pain sensitivity was assessed by the cuff-pressure procedure before and after exposure and by the cold pressor test after exposure only. When compared against the control condition, pain sensitivity diminished under conditions of hedonically positive affect. An inverse effect was suggested for hedonically negative conditions, but proved tentative and statistically unreliable. The findings are consistent with earlier demonstrations of mood effects on pain sensitivity. Unlike inconclusive earlier findings concerning the magnitude of directional effects, however, they suggest an asymmetry that emphasizes the pain-ameliorating effect of positive affects while lending little, if any, support to the proposal of a pain-sensitizing effect of negative affects. The investigation did not accomplish the intended creation of conditions necessary to test the proposal that heightened sympathetic activity diminishes pain sensitivity. The utility of a rigorous determination of this hypothesized relationship is emphasized, and procedures for a viable test of the proposal are suggested.
Pilger, Daniel; Khakban, Adak; Heukelbach, Jorg; Feldmeier, Hermann
2008-01-01
To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.
Costa, Aldo José Fernandes; Sarinho, Emanuel Sávio Cavalcanti; Motta, Maria Eugênia Farias Almeida; Gomes, Priscila Nogueira; de Oliveira de Melo, Sabrina Maria; da Silva, Giselia Alves Pontes
2011-02-01
Food allergy is an immunologically mediated adverse reaction to food protein. Cow's milk protein allergy (CMPA) is the most frequent type and is the one that is most difficult to diagnose. This study had the objective of analyzing the accuracy of hypersensitivity and specific IgE skin tests among children with CMPA and predominantly gastrointestinal clinical manifestations. The participants in this study were 192 children aged one and five (median of 2 yr). Among these, 122 underwent open oral challenge to the suspected food. After evaluating the sensitivity, specificity and positive and negative predictive values (respectively, PPV and NPV) of skin and specific IgE tests in relation to the gold standard (open oral challenge); all the children underwent the skin prick test (SPT), specific IgE test and atopy patch test (APT) for cow's milk, eggs, wheat and peanuts and the open oral challenge for the food to which the child was sensitive or had suspected sensitivity. Presence of food allergy was confirmed for 50 children (40.9%). Among these cases, 44/50 (88%) were of allergy to cow's milk protein. Children who presented a positive response to an oral challenge to cow's milk protein were considered to be cases, while the controls were children with negative response. Twenty-two of the 44 cases (50.0%) presented symptoms within the first 4 h after the challenge. The SPT presented 31.8% sensitivity, 90.3% specificity, 66.7% PPV and 68.4% NPV. The APT presented 25.0% sensitivity, 81.9% specificity, 45.8% PPV and 64.1% NPV. The specific IgE test presented, respectively, 20.5%, 88.9%, 52.9% and 64.6%. Despite the operational difficulty and the possible exposure risk, oral challenge is the best method for diagnosing CMPA, because of the low sensitivity and PPV of skin and specific IgE tests. © 2011 John Wiley & Sons A/S.
Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae
2017-01-01
ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887
Predispositions to approach and avoid are contextually sensitive and goal dependent.
Bamford, Susan; Ward, Robert
2008-04-01
The authors show that predispositions to approach and avoid do not consist simply of specific motor patterns but are more abstract functions that produce a desired environmental effect. It has been claimed that evaluating a visual stimulus as positive or negative evokes a specific motor response, extending the arm to negative stimuli, and contracting to positive stimuli. The authors showed that a large congruency effect (participants were faster to approach pleasant and avoid unpleasant stimuli, than to approach unpleasant and avoid pleasant stimuli) could be produced on a novel touchscreen paradigm (Experiment 1), and that the congruency effect could be reversed by spatial (Experiment 2) and nonspatial (Experiment 3) response effects. Thus, involuntary approach and avoid response activations are not fixed, but sensitive to context, and are specifically based on the desired goal. (Copyright) 2008 APA.
Singh, Ruchi; Singh, Dhirendra Pratap; Savargaonkar, Deepali; Singh, Om P; Bhatt, Rajendra M; Valecha, Neena
2017-01-01
Loop-mediated isothermal amplification (LAMP) is an emerging nucleic acid based diag- nostic approach that is easily adaptable to the field settings with limited technical resources. This study was aimed to evaluate the LAMP assay for the detection and identification of Plasmodium falciparum and P. vivax infection in malaria suspected cases using genus and species-specific assay. The 18S rRNA-based LAMP assay was evaluated for diagnosis of genus Plasmodium, and species- specific diagnosis of P. falciparum and P. vivax, infection employing 317 malaria suspected cases, and the results were compared with those obtained by 18S nested PCR (n-PCR). All the samples were confirmed by microscopy for the presence of Plasmodium parasite. The n-PCR was positive in all Plasmodium-infected cases (n=257; P. falciparum=133; P. vivax=124) and negative in microscopy negative cases (n=58) except for two cases which were positive for P. vivax, giving a sen- sitivity of 100% (95% CI: 97.04-100%) and a specificity of 100% (95% CI: 88.45-99.5%). Genus-specific LAMP assay missed 11 (3.2%) microscopy and n-PCR confirmed vivax malaria cases. Considering PCR results as a refer- ence, LAMP was 100% sensitive and specific for P. falciparum, whereas it exhibited 95.16% sensitivity and 96.7% specificity for P. vivax. The n-PCR assay detected 10 mixed infection cases while species-specific LAMP detected five mixed infection cases of P. vivax and P. falciparum, which were not detected by microscopy. Genus-specific LAMP assay displayed low sensitivity. Falciparum specific LAMP assay displayed high sensitivity whereas vivax specific LAMP assay displayed low sensitivity. Failed detection of vivax cases otherwise confirmed by the n-PCR assay indicates exploitation of new targets and improved detection methods to attain 100% results for P. vivax detection.
Ran, Li; Zhao, Wenli; Zhao, Ye; Bu, Huaien
2017-07-01
Contrast-enhanced ultrasound (CEUS) is considered a novel method for diagnosing pancreatic cancer, but currently, there is no conclusive evidence of its accuracy. Using CEUS in discriminating between pancreatic carcinoma and other pancreatic lesions, we aimed to evaluate the diagnostic accuracy of CEUS in predicting pancreatic tumours. Relevant studies were selected from the PubMed, Cochrane Library, Elsevier, CNKI, VIP, and WANFANG databases dating from January 2006 to May 2017. The following terms were used as keywords: "pancreatic cancer" OR "pancreatic carcinoma," "contrast-enhanced ultrasonography" OR "contrast-enhanced ultrasound" OR "CEUS," and "diagnosis." The selection criteria are as follows: pancreatic carcinomas diagnosed by CEUS while the main reference standard was surgical pathology or biopsy (if it involved a clinical diagnosis, particular criteria emphasized); SonoVue or Levovist was the contrast agent; true positive, false positive, false negative, and true negative rates were obtained or calculated to construct the 2 × 2 contingency table; English or Chinese articles; at least 20 patients were enrolled in each group. The Quality Assessment for Studies of Diagnostic Accuracy was employed to evaluate the quality of articles. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, summary receiver-operating characteristic curves, and the area under curve were evaluated to estimate the overall diagnostic efficiency. Pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with 95% confidence intervals (CIs) were calculated with fixed-effect models. Eight of 184 records were eligible for a meta-analysis after independent scrutinization by 2 reviewers. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were 0.86 (95% CI 0.81-0.90), 0.75 (95% CI 0.68-0.82), 3.56 (95% CI 2.64-4.78), 0.19 (95% CI 0.13-0.27), and 22.260 (95% CI 8.980-55.177), respectively. The area under the SROC curve was 0.9088. CEUS has a satisfying pooled sensitivity and specificity for discriminating pancreatic cancer from other pancreatic lesions.
Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro
2018-06-13
The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.
Saingam, Prakit; Li, Bo; Yan, Tao
2018-06-01
DNA-based molecular detection of microbial pathogens in complex environments is still plagued by sensitivity, specificity and robustness issues. We propose to address these issues by viewing them as inadvertent consequences of requiring specific and adequate amplification (SAA) of target DNA molecules by current PCR methods. Using the invA gene of Salmonella as the model system, we investigated if next generation sequencing (NGS) can be used to directly detect target sequences in false-negative PCR reaction (PCR-NGS) in order to remove the SAA requirement from PCR. False-negative PCR and qPCR reactions were first created using serial dilutions of laboratory-prepared Salmonella genomic DNA and then analyzed directly by NGS. Target invA sequences were detected in all false-negative PCR and qPCR reactions, which lowered the method detection limits near the theoretical minimum of single gene copy detection. The capability of the PCR-NGS approach in correcting false negativity was further tested and confirmed under more environmentally relevant conditions using Salmonella-spiked stream water and sediment samples. Finally, the PCR-NGS approach was applied to ten urban stream water samples and detected invA sequences in eight samples that would be otherwise deemed Salmonella negative. Analysis of the non-target sequences in the false-negative reactions helped to identify primer dime-like short sequences as the main cause of the false negativity. Together, the results demonstrated that the PCR-NGS approach can significantly improve method sensitivity, correct false-negative detections, and enable sequence-based analysis for failure diagnostics in complex environmental samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Ultrasound for Appendicitis: Performance and Integration with Clinical Parameters
Löfvenberg, Fanny
2016-01-01
Objective. To evaluate the performance of ultrasound in pediatric appendicitis and the integration of US with the pediatric appendicitis score (PAS) and C-reactive protein (CRP). Method. An institution-based, retrospective study of children who underwent abdominal US for suspected appendicitis between 2012 and 2015 at a tertiary pediatric surgery center. US results were dichotomized, with a nonvisualized appendix considered as a negative examination. Results. In total, 438 children were included (mean 8.5 years, 54% boys), with an appendicitis rate of 29%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US were 82%, 97%, 92%, and 93%, respectively, without significant age or gender differences. Pediatric radiologists had significantly higher sensitivity compared to general radiologists, 88% and 71%, respectively (p < 0.01), but no differences were seen for specificity, PPV, and NPV. The sensitivity, NPV, and negative likelihood ratio for the combination of negative US, PAS < 5, and CRP < 5 mg/L were 98%, 98%, and 0.05 (95% CI 0.03–0.15). Conclusion. US may be a useful tool for evaluating children with suspected appendicitis, regardless of age or gender, and should be the first choice of imaging modalities. Combining US with PAS and CRP may reduce several unnecessary admissions for in-hospital observation. PMID:28044133
Cytology versus HPV testing for cervical cancer screening in the general population.
Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc
2017-08-10
Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.
Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael
2017-12-01
The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.
Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren
2011-01-01
The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.
Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve
2011-01-01
Background In Norway, women with negative or low-grade cervical biopsies (normal/CIN1) are followed up after six months in order to decide on further follow-up or recall for screening at three-year intervals. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures whereas a low risk of high-grade disease among triage negative women assures safety. Materials and Methods At the University Hospital of North Norway, cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in post-colposcopy follow-up of women with negative or low-grade biopsy. In this study, women with negative biopsy after high grade cytology (ASC-H/HSIL) and/or positive HPV mRNA test in the period 2005–2009 were included (n = 520). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as study endpoint. Results Of 520 women with negative or low-grade biopsy, 124 women (23.8%) had CIN2+ in follow-up biopsy. The sensitivity and specificity of the HPV mRNA test were 89.1% (95% CI, 80.1–98.1) and 92.5% (95% CI, 88.2–96.7), respectively. The ratios of sensitivity, specificity and PPV of HPV mRNA testing compared to repeat cytology for finding CIN2+ was 1.05 (95% CI: 0.92–1.21), 1.21 (95% CI: 1.12–1.32), and 1.49 (95% CI: 1.20–1.86), respectively. The PPV of mRNA was 77.3% (95% CI, 59.8–94.8) in women aged 40 or older. Conclusion Women with negative cervical biopsy require follow-up before resumption of routine screening. Post-colposcopy HPV mRNA testing was as sensitive but more specific than post-colposcopy cytology. In addition, the HPV mRNA test showed higher PPV. A positive mRNA test post-colposcopy could justify treatment in women above 40 years. PMID:21998748
Luetkemeyer, Anne F; Kendall, Michelle A; Wu, Xingye; Lourenço, Maria Cristina; Jentsch, Ute; Swindells, Susan; Qasba, Sarojini S; Sanchez, Jorge; Havlir, Diane V; Grinsztejn, Beatriz; Sanne, Ian M; Firnhaber, Cynthia
2014-04-01
Limited performance data from line probe assays (LPAs), nucleic acid tests used for the rapid diagnosis of tuberculosis (TB), nontuberculosis mycobacteria (NTM), and Mycobacterium tuberculosis drug resistance are available for HIV-infected individuals, in whom paucibacillary TB is common. In this study, the strategy of testing sputum with GenoType MTBDRplus (MTBDR-Plus) and GenoType Direct LPA (Direct LPA) was compared to a gold standard of one mycobacterial growth indicator tube (MGIT) liquid culture. HIV-positive (HIV(+)) individuals with suspected TB from southern Africa and South America with <7 days of TB treatment had 1 sputum specimen tested with Direct LPA, MTBDR-Plus LPA, smear microscopy, MGIT, biochemical identification of mycobacterial species, and culture-based drug-susceptibility testing (DST). Of 639 participants, 59.3% were MGIT M. tuberculosis culture positive, of which 276 (72.8%) were acid-fast bacillus (AFB) smear positive. MTBDR-Plus had a sensitivity of 81.0% and a specificity of 100%, with sensitivities of 44.1% in AFB smear-negative versus 94.6% in AFB smear-positive specimens. For specimens that were positive for M. tuberculosis by MTBDR-Plus, the sensitivity and specificity for rifampin resistance were 91.7% and 96.6%, respectively, and for isoniazid (INH) they were 70.6% and 99.1%. The Direct LPA had a sensitivity of 88.4% and a specificity of 94.6% for M. tuberculosis detection, with a sensitivity of 72.5% in smear-negative specimens. Ten of 639 MGIT cultures grew Mycobacterium avium complex or Mycobacterium kansasii, half of which were detected by Direct LPA. Both LPA assays performed well in specimens from HIV-infected individuals, including in AFB smear-negative specimens, with 72.5% sensitivity for M. tuberculosis identification with the Direct LPA and 44.1% sensitivity with MTBDR-Plus. LPAs have a continued role for use in settings where rapid identification of INH resistance and clinically relevant NTM are priorities.
Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia
Dinh, C H; Ng, R; Grandinetti, A; Joffe, A; Chow, D C
2006-01-01
Background An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gap's poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate ⩾2.5 mmol/l. Methods A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients' laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated. Results An anion gap ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively. Conclusions The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia. PMID:16858097
Theurer, M E; White, B J; Larson, R L; Schroeder, T C
2015-03-01
Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (<15%) and high (≥15%) groups. For both apparent prevalence categories, increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.
Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L
2009-04-22
Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.
Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A
2016-06-01
Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin
2017-01-01
To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.
Abràmoff, Michael David; Lou, Yiyue; Erginay, Ali; Clarida, Warren; Amelon, Ryan; Folk, James C; Niemeijer, Meindert
2016-10-01
To compare performance of a deep-learning enhanced algorithm for automated detection of diabetic retinopathy (DR), to the previously published performance of that algorithm, the Iowa Detection Program (IDP)-without deep learning components-on the same publicly available set of fundus images and previously reported consensus reference standard set, by three US Board certified retinal specialists. We used the previously reported consensus reference standard of referable DR (rDR), defined as International Clinical Classification of Diabetic Retinopathy moderate, severe nonproliferative (NPDR), proliferative DR, and/or macular edema (ME). Neither Messidor-2 images, nor the three retinal specialists setting the Messidor-2 reference standard were used for training IDx-DR version X2.1. Sensitivity, specificity, negative predictive value, area under the curve (AUC), and their confidence intervals (CIs) were calculated. Sensitivity was 96.8% (95% CI: 93.3%-98.8%), specificity was 87.0% (95% CI: 84.2%-89.4%), with 6/874 false negatives, resulting in a negative predictive value of 99.0% (95% CI: 97.8%-99.6%). No cases of severe NPDR, PDR, or ME were missed. The AUC was 0.980 (95% CI: 0.968-0.992). Sensitivity was not statistically different from published IDP sensitivity, which had a CI of 94.4% to 99.3%, but specificity was significantly better than the published IDP specificity CI of 55.7% to 63.0%. A deep-learning enhanced algorithm for the automated detection of DR, achieves significantly better performance than a previously reported, otherwise essentially identical, algorithm that does not employ deep learning. Deep learning enhanced algorithms have the potential to improve the efficiency of DR screening, and thereby to prevent visual loss and blindness from this devastating disease.
Wall, Stephen P; Mayorga, Oliver; Banfield, Christine E; Wall, Mark E; Aisic, Ilan; Auerbach, Carl; Gennis, Paul
2006-11-01
To develop software that categorizes electronic head computed tomography (CT) reports into groups useful for clinical decision rule research. Data were obtained from the Second National Emergency X-Radiography Utilization Study, a cohort of head injury patients having received head CT. CT reports were reviewed manually for presence or absence of clinically important subdural or epidural hematoma, defined as greater than 1.0 cm in width or causing mass effect. Manual categorization was done by 2 independent researchers blinded to each other's results. A third researcher adjudicated discrepancies. A random sample of 300 reports with radiologic abnormalities was selected for software development. After excluding reports categorized manually or by software as indeterminate (neither positive nor negative), we calculated sensitivity and specificity by using manual categorization as the standard. System efficiency was defined as the percentage of reports categorized as positive or negative, regardless of accuracy. Software was refined until analysis of the training data yielded sensitivity and specificity approximating 95% and efficiency exceeding 75%. To test the system, we calculated sensitivity, specificity, and efficiency, using the remaining 1,911 reports. Of the 1,911 reports, 160 had clinically important subdural or epidural hematoma. The software exhibited good agreement with manual categorization of all reports, including indeterminate ones (weighted kappa 0.62; 95% confidence interval [CI] 0.58 to 0.65). Sensitivity, specificity, and efficiency of the computerized system for identifying manual positives and negatives were 96% (95% CI 91% to 98%), 98% (95% CI 98% to 99%), and 79% (95% CI 77% to 80%), respectively. Categorizing head CT reports by computer for clinical decision rule research is feasible.
Le, Tham; O’Brien, Katherine L.; Murdoch, David R.; Prosperi, Christine; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Kotloff, Karen L.; Levine, Orin S.; Scott, J. Anthony G.; Thea, Donald M.; Awori, Juliet O.; Baillie, Vicky L.; Cascio, Stephanie; Chuananon, Somchai; DeLuca, Andrea N.; Driscoll, Amanda J.; Ebruke, Bernard E.; Endtz, Hubert P.; Kaewpan, Anek; Kahn, Geoff; Karani, Angela; Karron, Ruth A.; Moore, David P.; Park, Daniel E.; Rahman, Mohammed Ziaur; Salaudeen, Rasheed; Seidenberg, Phil; Somwe, Somwe Wa; Sylla, Mamadou; Tapia, Milagritos D.; Zeger, Scott L.; Deloria Knoll, Maria; Madhi, Shabir A.; O’Brien, Katherine L.; Levine, Orin S.; Knoll, Maria Deloria; Feikin, Daniel R.; DeLuca, Andrea N.; Driscoll, Amanda J.; Fancourt, Nicholas; Fu, Wei; Hammitt, Laura L.; Higdon, Melissa M.; Kagucia, E. Wangeci; Karron, Ruth A.; Li, Mengying; Park, Daniel E.; Prosperi, Christine; Wu, Zhenke; Zeger, Scott L.; Watson, Nora L.; Crawley, Jane; Murdoch, David R.; Brooks, W. Abdullah; Endtz, Hubert P.; Zaman, Khalequ; Goswami, Doli; Hossain, Lokman; Jahan, Yasmin; Ashraf, Hasan; Howie, Stephen R. C.; Ebruke, Bernard E.; Antonio, Martin; McLellan, Jessica; Machuka, Eunice; Shamsul, Arifin; Zaman, Syed M.A.; Mackenzie, Grant; Scott, J. Anthony G.; Awori, Juliet O.; Morpeth, Susan C.; Kamau, Alice; Kazungu, Sidi; Ominde, Micah Silaba; Kotloff, Karen L.; Tapia, Milagritos D.; Sow, Samba O.; Sylla, Mamadou; Tamboura, Boubou; Onwuchekwa, Uma; Kourouma, Nana; Toure, Aliou; Madhi, Shabir A.; Moore, David P.; Adrian, Peter V.; Baillie, Vicky L.; Kuwanda, Locadiah; Mudau, Azwifarwi; Groome, Michelle J.; Mahomed, Nasreen; Baggett, Henry C.; Thamthitiwat, Somsak; Maloney, Susan A.; Bunthi, Charatdao; Rhodes, Julia; Sawatwong, Pongpun; Akarasewi, Pasakorn; Thea, Donald M.; Mwananyanda, Lawrence; Chipeta, James; Seidenberg, Phil; Mwansa, James; Wa Somwe, Somwe; Kwenda, Geoffrey; Anderson, Trevor P.; Mitchell, Joanne
2017-01-01
Abstract Background. Lack of a gold standard for identifying bacterial and viral etiologies of pneumonia has limited evaluation of C-reactive protein (CRP) for identifying bacterial pneumonia. We evaluated the sensitivity and specificity of CRP for identifying bacterial vs respiratory syncytial virus (RSV) pneumonia in the Pneumonia Etiology Research for Child Health (PERCH) multicenter case-control study. Methods. We measured serum CRP levels in cases with World Health Organization–defined severe or very severe pneumonia and a subset of community controls. We evaluated the sensitivity and specificity of elevated CRP for “confirmed” bacterial pneumonia (positive blood culture or positive lung aspirate or pleural fluid culture or polymerase chain reaction [PCR]) compared to “RSV pneumonia” (nasopharyngeal/oropharyngeal or induced sputum PCR-positive without confirmed/suspected bacterial pneumonia). Receiver operating characteristic (ROC) curves were constructed to assess the performance of elevated CRP in distinguishing these cases. Results. Among 601 human immunodeficiency virus (HIV)–negative tested controls, 3% had CRP ≥40 mg/L. Among 119 HIV-negative cases with confirmed bacterial pneumonia, 77% had CRP ≥40 mg/L compared with 17% of 556 RSV pneumonia cases. The ROC analysis produced an area under the curve of 0.87, indicating very good discrimination; a cut-point of 37.1 mg/L best discriminated confirmed bacterial pneumonia (sensitivity 77%) from RSV pneumonia (specificity 82%). CRP ≥100 mg/L substantially improved specificity over CRP ≥40 mg/L, though at a loss to sensitivity. Conclusions. Elevated CRP was positively associated with confirmed bacterial pneumonia and negatively associated with RSV pneumonia in PERCH. CRP may be useful for distinguishing bacterial from RSV-associated pneumonia, although its role in discriminating against other respiratory viral-associated pneumonia needs further study. PMID:28575375
Accuracy of a Mouse Bioassay for the Diagnosis of Botulism in Horses.
Johnson, A L; McAdams-Gallagher, S C; Aceto, H
2016-07-01
The laboratory diagnosis of botulism in horses traditionally has relied upon the mouse bioassay (MBA). The accuracy of this test for the diagnosis of botulism in horses is unknown. Our goal was to determine the sensitivity, specificity, positive predictive value, and negative predictive value of the MBA on laboratory-processed fecal and gastrointestinal samples for foals and adult horses. Cases included all horses with a final clinical diagnosis of botulism that were admitted between 1986 and 2011 and had MBA testing performed. Controls included horses without botulism that were admitted during the same time period and had MBA testing performed. Retrospective study. Horses suspected of having botulism had fecal or (less commonly) gastrointestinal content samples tested using MBA. For every hospitalized botulism suspect, control samples were obtained from ≥1 additional hospitalized horses not suspected to have botulism. One hundred and twenty-nine adult horses and 253 adult controls were identified. Overall sensitivity of the MBA was only 32% but specificity was 97%. Forty-three foal cases and 21 foal controls were evaluated; sensitivity of the MBA was 53% and specificity was 100%. Positive predictive value was substantially higher (100% for foals and 89% for adults) than negative predictive value (51% for foals and 67% for adults). Mouse bioassay has low sensitivity but high specificity for the diagnosis of botulism in horses. Positive results are highly suggestive of botulism but negative results do not exclude the diagnosis. Unaffected horses and foals rarely shed C. botulinum in their feces. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Jiang, Lindi; Wang, Zhen; Dai, Xiaomin; Jin, Xuejuan
2011-04-01
To determine the value of clinical measures in diagnosis of adult-onset Still's disease (AOSD), and to identify the optimal set of proposed classification criteria, in a Chinese population. A total of 70 patients with AOSD and 140 non-AOSD inpatients with fever were retrospectively identified at Zhongshan Hospital, Shanghai, from January 2003 to December 2009. Clinical measures and 4 sets of diagnostic criteria (Yamaguchi, Calabro, Cush, and Reginato) were evaluated by sensitivity, specificity, positive/negative predictive value (PPV, NPV), and positive/negative likelihood ratio (PLR, NLR) for diagnosis of AOSD. In our series, higher sensitivity included hyperpyrexia (temperature ≥ 39°C, 94.29%), arthralgia (80.0%), polymorphonuclear neutrophils (PMN) ≥ 75% (84.29%), serum ferritin ≥ 2-fold the upper normal value (90.0%), negative antinuclear antibodies (85.29%), and rheumatoid factor (84.38%); while higher specificity included transient erythema (98.57%), sore throat (85.0%), leukocytes ≥ 15,000/mm(3) (87.86%), and PMN ≥ 85% (85.0%). Rash, arthralgia, and sore throat were found to have better sensitivity and specificity (PLR 3.29-4.86). Leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were set as critical points. The Reginato criteria set had the highest specificity, 99.29%. The Yamaguchi set had the highest sensitivity, 78.57%, with a better accuracy of 87.14%. The Yamaguchi diagnostic criteria had better accuracy in Chinese patients. Indicators such as rash, arthralgia, sore throat, leukocytes ≥ 10,000/mm(3), PMN ≥ 80%, and serum ferritin ≥ 5-fold the upper normal limit were helpful for diagnosis of AOSD. We recommend using these indicators in combination instead of alone.
Should cell-free DNA testing be used to target antenatal rhesus immune globulin administration?
Ma, Kimberly K; Rodriguez, Maria I; Cheng, Yvonne W; Norton, Mary E; Caughey, Aaron B
2016-01-01
To compare the rates of alloimmunization with the use of cell-free DNA (cfDNA) screening to target antenatal rhesus immune globulin (RhIG) prenatally, versus routine administration of RhIG in rhesus D (RhD)-negative pregnant women in a theoretic cohort using a decision-analytic model. A decision-analytic model compared cfDNA testing to routine antenatal RhIG administration. The primary outcome was maternal sensitization to RhD antigen. Sensitivity and specificity of cfDNA testing were assumed to be 99.8% and 95.3%, respectively. Univariate and bivariate sensitivity analyses, Monte Carlo simulation, and threshold analyses were performed. In a cohort of 10,000 RhD-negative women, 22.6 sensitizations would occur with utilization of cfDNA, while 20 sensitizations would occur with routine RhIG. Only when the sensitivity of the cfDNA test reached 100%, the rate of sensitization was equal for both cfDNA and RhIG. Otherwise, routine RhIG minimized the rate of sensitization, especially given RhIG is readily available in the United States. Adoption of cfDNA testing would result in a 13.0% increase in sensitization among RhD-negative women in a theoretical cohort taking into account the ethnic diversity of the United States' population.
Wang, Ting; Liu, Mei; Zheng, Su-Jun; Bian, Dan-Dan; Zhang, Jin-Yan; Yao, Jia; Zheng, Qing-Fen; Shi, A-Meng; Li, Wen-Han; Li, Lu; Chen, Yu; Wang, Jin-Hai; Duan, Zhong-Ping; Dong, Lei
2017-05-21
To determine the prevalence and diagnostic value of autoantibodies in α-fetoprotein (AFP)-negative hepatocellular carcinoma (HCC). Fifty-six serum samples from AFP-negative HCC cases, 86 from AFP-positive HCC cases, 168 from chronic liver disease cases, and 59 from normal human controls were included in this study. Autoantibodies to nucleophosmin (NPM)1, 14-3-3zeta and mouse double minute 2 homolog (MDM2) proteins in AFP-negative HCC serum were evaluated by enzyme-linked immunosorbent assay. Partially positive sera were further evaluated by western blotting. Immunohistochemistry was used to detect the expression of three tumor-associated antigens (TAAs) in AFP-negative HCC and normal control tissues. The frequency of autoantibodies to the three TAAs in AFP-negative HCC sera was 21.4%, 19.6% and 19.6%, which was significantly higher than in the chronic liver disease cases and normal human controls ( P < 0.01) as well as AFP-positive HCC cases. The sensitivity of the three autoantibodies for diagnosis of AFP-negative HCC ranged from 19.6% to 21.4%, and the specificity was approximately 95%. When the three autoantibodies were combined, the sensitivity reached 30.4% and the specificity reached 91.6%. Autoantibodies to NPM1, 14-3-3zeta and MDM2 may be useful biomarkers for immunodiagnosis of AFP-negative HCC.
Wang, Ting; Liu, Mei; Zheng, Su-Jun; Bian, Dan-Dan; Zhang, Jin-Yan; Yao, Jia; Zheng, Qing-Fen; Shi, A-Meng; Li, Wen-Han; Li, Lu; Chen, Yu; Wang, Jin-Hai; Duan, Zhong-Ping; Dong, Lei
2017-01-01
AIM To determine the prevalence and diagnostic value of autoantibodies in α-fetoprotein (AFP)-negative hepatocellular carcinoma (HCC). METHODS Fifty-six serum samples from AFP-negative HCC cases, 86 from AFP-positive HCC cases, 168 from chronic liver disease cases, and 59 from normal human controls were included in this study. Autoantibodies to nucleophosmin (NPM)1, 14-3-3zeta and mouse double minute 2 homolog (MDM2) proteins in AFP-negative HCC serum were evaluated by enzyme-linked immunosorbent assay. Partially positive sera were further evaluated by western blotting. Immunohistochemistry was used to detect the expression of three tumor-associated antigens (TAAs) in AFP-negative HCC and normal control tissues. RESULTS The frequency of autoantibodies to the three TAAs in AFP-negative HCC sera was 21.4%, 19.6% and 19.6%, which was significantly higher than in the chronic liver disease cases and normal human controls (P < 0.01) as well as AFP-positive HCC cases. The sensitivity of the three autoantibodies for diagnosis of AFP-negative HCC ranged from 19.6% to 21.4%, and the specificity was approximately 95%. When the three autoantibodies were combined, the sensitivity reached 30.4% and the specificity reached 91.6%. CONCLUSION Autoantibodies to NPM1, 14-3-3zeta and MDM2 may be useful biomarkers for immunodiagnosis of AFP-negative HCC. PMID:28596685
Kodani, Maja; Mixson-Hayden, Tonya; Drobeniuc, Jan; Kamili, Saleem
2014-10-01
Five viruses have been etiologically associated with viral hepatitis. Nucleic acid testing (NAT) remains the gold standard for diagnosis of viremic stages of infection. NAT methodologies have been developed for all hepatitis viruses; however, a NAT-based assay that can simultaneously detect all five viruses is not available. We designed TaqMan card-based assays for detection of HAV RNA, HBV DNA, HCV RNA, HDV RNA and HEV RNA. The performances of individual assays were evaluated on TaqMan Array Cards (TAC) for detecting five viral genomes simultaneously. Sensitivity and specificity were determined by testing 329 NAT-tested clinical specimens. All NAT-positive samples for HCV (n = 32), HDV (n = 28) and HEV (n = 14) were also found positive in TAC (sensitivity, 100%). Forty-three of 46 HAV-NAT positive samples were also positive in TAC (sensitivity, 94%), while 36 of 39 HBV-NAT positive samples were positive (sensitivity, 92%). No false-positives were detected for HBV (n = 32), HCV (n = 36), HDV (n = 30), and HEV (n = 31) NAT-negative samples (specificity 100%), while 38 of 41 HAV-NAT negative samples were negative by TAC (specificity 93%). TAC assay was concordant with corresponding individual NATs for hepatitis A-E viral genomes and can be used for their detection simultaneously. The TAC assay has potential for use in hepatitis surveillance, for screening of donor specimens and in outbreak situations. Wider availability of TAC-ready assays may allow for customized assays, for improving acute jaundice surveillance and for other purposes for which there is need to identify multiple pathogens rapidly. Published by Elsevier B.V.
Bilal, Muhammad; Tariq, Hina; Mamoon, Nadira
2018-01-01
Margin assessment is done in Whipple procedures which are usually performed to resect tumours of head of pancreas and ampullary/periampullary region. Aims and objective of the study are to determine the concordance between frozen sections (FS) and permanent sections (PS) of surgical margins in Whipple resections. It is a retrospective study, from January 2008 to January 2015 (07 years). It includes the specimen with malignancy in final report and for which FS of pancreatic and/or CBD margin(s) were requested. Data was retrieved from Laboratory information system (LIS) database. Of the 41 bile duct margins in cases of ampullary tumours, 03 were positive on FS as well as PS, 35 were negative on FS as well as on PS. Results showed 100% sensitivity, 92.1% specificity, 50% PPV and 100% NPV. Results of 36 pancreatic margins in cases of ampullary showed 100% sensitivity, 97.1% specificity, 50% PPV and 100% NPV. In pancreatic carcinoma cases, none of CBD margins were reported as positive on FS, 02 margins reported as negative were found positive on PS, while 17 were negative on FS as well as PS. Results showed 100% specificity and 89.5% NPV. Of the 27 pancreatic margins tested in pancreatic tumours 100% sensitivity, 94.1% specificity, 88.9% PPV and 100% NPV was found. Factors such as absent prior tissue diagnosis and/or inflammatory processes make margin diagnosis difficult. However, a high concordance was observed between our FS and PS diagnosis.
An in vitro human skin test for assessing sensitization potential.
Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M
2016-05-01
Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.
B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones
Harper, Jonathan D.; Hsi, Ryan S.; Shah, Anup R.; Dighe, Manjiri K.; Carter, Stephen J.; Moshiri, Mariam; Paun, Marla; Lu, Wei; Bailey, Michael R.
2013-01-01
Abstract Purpose To compare color Doppler twinkling artifact and B-mode ultrasonography in detecting kidney stones. Patients and Methods Nine patients with recent CT scans prospectively underwent B-mode and twinkling artifact color Doppler ultrasonography on a commercial ultrasound machine. Video segments of the upper pole, interpolar area, and lower pole were created, randomized, and independently reviewed by three radiologists. Receiver operator characteristics were determined. Results There were 32 stones in 18 kidneys with a mean stone size of 8.9±7.5 mm. B-mode ultrasonography had 71% sensitivity, 48% specificity, 52% positive predictive value, and 68% negative predictive value, while twinkling artifact Doppler ultrasonography had 56% sensitivity, 74% specificity, 62% positive predictive value, and 68% negative predictive value. Conclusions When used alone, B-mode is more sensitive, but twinkling artifact is more specific in detecting kidney stones. This information may help users employ twinkling and B-mode to identify stones and developers to improve signal processing to harness the fundamental acoustic differences to ultimately improve stone detection. PMID:23067207
2011-01-01
Background Computerized Clinical Records, which are incorporated in primary health care practice, have great potential for research. In order to use this information, data quality and reliability must be assessed to prevent compromising the validity of the results. The aim of this study is to validate the diagnosis of hypertension and diabetes mellitus in the computerized clinical records of primary health care, taking the diagnosis criteria established in the most prominently used clinical guidelines as the gold standard against which what measure the sensitivity, specificity, and determine the predictive values. The gold standard for diabetes mellitus was the diagnostic criteria established in 2003 American Diabetes Association Consensus Statement for diabetic subjects. The gold standard for hypertension was the diagnostic criteria established in the Joint National Committee published in 2003. Methods A cross-sectional multicentre validation study of diabetes mellitus and hypertension diagnoses in computerized clinical records of primary health care was carried out. Diagnostic criteria from the most prominently clinical practice guidelines were considered for standard reference. Sensitivity, specificity, positive and negative predictive values, and global agreement (with kappa index), were calculated. Results were shown overall and stratified by sex and age groups. Results The agreement for diabetes mellitus with the reference standard as determined by the guideline was almost perfect (κ = 0.990), with a sensitivity of 99.53%, a specificity of 99.49%, a positive predictive value of 91.23% and a negative predictive value of 99.98%. Hypertension diagnosis showed substantial agreement with the reference standard as determined by the guideline (κ = 0.778), the sensitivity was 85.22%, the specificity 96.95%, the positive predictive value 85.24%, and the negative predictive value was 96.95%. Sensitivity results were worse in patients who also had diabetes and in those aged 70 years or over. Conclusions Our results substantiate the validity of using diagnoses of diabetes and hypertension found within the computerized clinical records for epidemiologic studies. PMID:22035202
Diagnostic accuracy of the urinalysis for urinary tract infection in infants <3 months of age.
Schroeder, Alan R; Chang, Pearl W; Shen, Mark W; Biondi, Eric A; Greenhow, Tara L
2015-06-01
The 2011 American Academy of Pediatrics urinary tract infection (UTI) guideline suggests incorporation of a positive urinalysis (UA) into the definition of UTI. However, concerns linger over UA sensitivity in young infants. Infants with the same pathogenic organism in the blood and urine (bacteremic UTI) have true infections and represent a desirable population for examination of UA sensitivity. We collected UA results on a cross-sectional sample of 276 infants <3 months of age with bacteremic UTI from 11 hospital systems. Sensitivity was calculated on infants who had at least a partial UA performed and had ≥50 000 colony-forming units per milliliter from the urine culture. Specificity was determined by using a random sample of infants from the central study site with negative urine cultures. The final sample included 245 infants with bacteremic UTI and 115 infants with negative urine cultures. The sensitivity of leukocyte esterase was 97.6% (95% confidence interval [CI] 94.5%-99.2%) and of pyuria (>3 white blood cells/high-power field) was 96% (95% CI 92.5%-98.1%). Only 1 infant with bacteremic UTI (Group B Streptococcus) and a complete UA had an entirely negative UA. In infants with negative urine cultures, leukocyte esterase specificity was 93.9% (95% CI 87.9 - 97.5) and of pyuria was 91.3% (84.6%-95.6%). In young infants with bacteremic UTI, UA sensitivity is higher than previous reports in infants with UTI in general. This finding can be explained by spectrum bias or by inclusion of faulty gold standards (contaminants or asymptomatic bacteriuria) in previous studies. Copyright © 2015 by the American Academy of Pediatrics.
False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.
Katz, Alan R; Komeya, Alan Y; Tomas, Juval E
2017-06-01
We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.
Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian
2017-01-01
Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474
Grinsvall, Cecilia; Törnblom, Hans; Tack, Jan; Van Oudenhove, Lukas; Simrén, Magnus
2018-01-01
Background and objective Psychological states may interfere with visceral sensitivity. Here we investigate associations between psychosocial factors and visceral sensitivity in irritable bowel syndrome (IBS). Methods Two IBS patient cohorts (Cohort 1: n = 231, Rome II; Cohort 2: n = 141, Rome III) underwent rectal barostat testing, and completed questionnaires for anxiety, depression, somatization, and abuse. The associations between questionnaire measures and visceral sensitivity parameters were analyzed in three-step general linear models (step1: demographic and abuse variables; step 2: anxiety and depression; step 3: somatization). Results Cohort 1. Pain threshold was positively associated with age and female gender, and negatively with adult sexual abuse and somatization. Pain referral area was negatively associated with age and positively with somatization and GI-specific anxiety, the latter effect mediated by somatization. Cohort 2. Pain threshold was positively associated with age and male gender, and negatively with adult sexual abuse. Pain intensity ratings were positively associated with somatization, female gender and depression, the latter effect mediated by somatization. Conclusion Somatization is associated with most visceral sensitivity parameters, and mediates the effect of some psychological factors on visceral sensitivity. It may reflect a psychobiological sensitization process driving symptom generation in IBS. In addition, abuse history was found to independently affect some visceral sensitivity parameters. PMID:29511560
Connectome sensitivity or specificity: which is more important?
Zalesky, Andrew; Fornito, Alex; Cocchi, Luca; Gollo, Leonardo L; van den Heuvel, Martijn P; Breakspear, Michael
2016-11-15
Connectomes with high sensitivity and high specificity are unattainable with current axonal fiber reconstruction methods, particularly at the macro-scale afforded by magnetic resonance imaging. Tensor-guided deterministic tractography yields sparse connectomes that are incomplete and contain false negatives (FNs), whereas probabilistic methods steered by crossing-fiber models yield dense connectomes, often with low specificity due to false positives (FPs). Densely reconstructed probabilistic connectomes are typically thresholded to improve specificity at the cost of a reduction in sensitivity. What is the optimal tradeoff between connectome sensitivity and specificity? We show empirically and theoretically that specificity is paramount. Our evaluations of the impact of FPs and FNs on empirical connectomes indicate that specificity is at least twice as important as sensitivity when estimating key properties of brain networks, including topological measures of network clustering, network efficiency and network modularity. Our asymptotic analysis of small-world networks with idealized modular structure reveals that as the number of nodes grows, specificity becomes exactly twice as important as sensitivity to the estimation of the clustering coefficient. For the estimation of network efficiency, the relative importance of specificity grows linearly with the number of nodes. The greater importance of specificity is due to FPs occurring more prevalently between network modules rather than within them. These spurious inter-modular connections have a dramatic impact on network topology. We argue that efforts to maximize the sensitivity of connectome reconstruction should be realigned with the need to map brain networks with high specificity. Copyright © 2016 Elsevier Inc. All rights reserved.
Otto, Michael W; Eastman, Abraham; Lo, Stephen; Hearon, Bridget A; Bickel, Warren K; Zvolensky, Michael; Smits, Jasper A J; Doan, Stacey N
2016-11-01
Understanding the nature and influence of specific risk profiles is increasingly important for health behavior promotion. The purpose of this article is to document the value of two factors-anxiety sensitivity (AS) and working memory capacity (WMC)-for enhancing risk for the initiation and/or maintenance of a range of negative health behaviors. AS is a distress-related risk factor that potentiates avoidance/coping motivations for negative health behaviors. Stress provides the conditions for negative somatic and affective states, and AS amplifies the aversiveness of these experiences and correspondingly hinders adaptive functioning. In contrast, low WMC is hypothesized to exert its effect by decreasing the capacity to filter out current temptations, attenuating a focus on longer-term goals and impairing the application of relevant coping skills at times of stress. In this review, we provide conceptual models for the separate roles of high AS and low WMC in negative health behaviors, review the influence of these factors on specific health behavior exemplars (eating behaviors/obesity, physical activity, smoking, alcohol use, and sleep promotion), provide preliminary evidence for their value as independent treatment targets for health-behavior promotion, and encourage specific research directions in relation to these variables. Copyright © 2016. Published by Elsevier Ltd.
Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid
2015-12-01
Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.
Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?
Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul
2012-01-01
BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.
de Olim, Carlo; Bégin, Denis; Boulet, Louis-Philippe; Cartier, André; Gérin, Michel; Lemière, Catherine
2015-01-01
BACKGROUND: Specific inhalation challenges (SIC) enable the identification of the agent responsible of occupational asthma (OA). A clinician may fail to identify a specific agent in the workplace, which may potentially lead to a misdiagnosis. The expert assessment method performed by an occupational hygienist has been used to evaluate occupational exposures in epidemiological studies. OBJECTIVE: The broad aim of the present study was to evaluate the contribution of an expert assessment performed by an occupational hygienist to the diagnosis of OA. The specific aim was to compare work-place exposures identified by an occupational hygienist and by chest physicians in subjects with positive SICs and subjects with asthma, but with a negative SIC. METHODS: SICs were performed in 120 cases: 67 were positive and 53 were negative. A clinician assessed occupational exposures to sensitizers during a routine clinical evaluation preceding the performance of the SIC. An expert assessment of occupational exposures was performed by an occupational hygienist blind to the result of the SIC. RESULTS: The occupational hygienist identified the causal agent in 96.7% of the 61 cases of positive SIC. In 33 (62.3%) cases of negative SICs, the occupational hygienist identified ≥1 sensitizing agent(s) that had not been identified by the clinician. CONCLUSION: The hygienist identified the causal agent in almost all subjects with OA. In contrast, the clinician failed to identify potential exposures to sensitizers in >60% of the negative SIC subjects, which may have resulted in some subjects being misdiagnosed as not having OA. PMID:26422401
Suwanpimolkul, Gompol; Kawkitinarong, Kamon; Manosuthi, Weerawat; Sophonphan, Jiratchaya; Gatechompol, Sivaporn; Ohata, Pirapon June; Ubolyam, Sasiwimol; Iampornsin, Thatri; Katerattanakul, Pairaj; Avihingsanon, Anchalee; Ruxrungtham, Kiat
2017-06-01
To evaluate the applicability and accuracy of the urine lipoarabinomannan (LAM) test in tuberculosis (TB)/HIV co-infected patients and HIV-negative patients with disseminated TB. Frozen urine samples obtained at baseline from patients in the TB research cohort with proven culture-positive TB were selected for blinded urine LAM testing. One hundred and nine patients were categorized into four groups: (1) HIV-positive patients with TB; (2) HIV-negative patients with disseminated TB; (3) HIV-negative immunocompromised patients with TB; and (4) patients with diseases other than TB. The sensitivity of urine LAM testing for culture-positive TB, specificity of urine LAM testing for patients without TB, positive predictive value (PPV), and negative predictive value (NPV) were assessed. The sensitivity of the urine LAM test in group 1 patients with a CD4 T-cell count of >100, ≤100, and ≤50 cells/mm 3 was 38.5%, 40.6%, and 45%, respectively. The specificity and PPV of the urine LAM test were >80%. The sensitivity of the test was 20% in group 2 and 12.5% in group 3, and the specificity and PPV were 100% for both groups. A positive urine LAM test result was significantly associated with death. This promising diagnostic tool could increase the yield of TB diagnosis and may predict the mortality rate of TB infection, particularly in TB/HIV co-infected patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Periprosthetic infection: where do we stand with regard to Gram stain?
Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert; Parvizi, Javad
2009-02-01
One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. A positive gram stain was defined as the visualization of bacterial cells or "many neutrophils" (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. The presence of organisms and "many" neutrophils on a Gram smear had high specificity (98-100%) and positive predictive value (89-100%) in both THA and TKA. The sensitivities (30-50%) and negative predictive values (70-79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43-64% and 82%, respectively). Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests.
Manzanares-Laya, S; Burón, A; Murta-Nascimento, C; Servitja, S; Castells, X; Macià, F
2014-01-01
Hospital cancer registries and hospital databases are valuable and efficient sources of information for research into cancer recurrences. The aim of this study was to develop and validate algorithms for the detection of breast cancer recurrence. A retrospective observational study was conducted on breast cancer cases from the cancer registry of a third level university hospital diagnosed between 2003 and 2009. Different probable cancer recurrence algorithms were obtained by linking the hospital databases and the construction of several operational definitions, with their corresponding sensitivity, specificity, positive predictive value and negative predictive value. A total of 1,523 patients were diagnosed of breast cancer between 2003 and 2009. A request for bone gammagraphy after 6 months from the first oncological treatment showed the highest sensitivity (53.8%) and negative predictive value (93.8%), and a pathology test after 6 months after the diagnosis showed the highest specificity (93.8%) and negative predictive value (92.6%). The combination of different definitions increased the specificity and the positive predictive value, but decreased the sensitivity. Several diagnostic algorithms were obtained, and the different definitions could be useful depending on the interest and resources of the researcher. A higher positive predictive value could be interesting for a quick estimation of the number of cases, and a higher negative predictive value for a more exact estimation if more resources are available. It is a versatile and adaptable tool for other types of tumors, as well as for the needs of the researcher. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Immunohistochemical expression of p16 in lipoblastomas.
Cappellesso, Rocco; d'Amore, Emanuele S G; Dall'Igna, Patrizia; Guzzardo, Vincenza; Vassarotto, Elisa; Rugge, Massimo; Alaggio, Rita
2016-01-01
Lipoblastoma (LB) is a rare benign adipocytic tumor of childhood occasionally showing histological similarities to myxoid liposarcoma (ML) or well-differentiated liposarcoma (WDL). p16 immunohistochemistry has proved to be useful in distinguishing various types of liposarcomas, in particular WDL from lipoma, with higher sensitivity and specificity than MDM2 and CDK4 immunohistochemistry. In this study, we reported the histologic features of a series of 30 LB with emphasis on the potential diagnostic pitfalls and investigated the immunohistochemical expression of p16. Moreover, p16 immunostaining was performed in 16 liposarcomas (11 WDL and 5 ML), 16 lipomas, and 16 cases of liponecrosis in order to evaluate its usefulness in the differential diagnosis of challenging lesions occurring in older children. Overall, p16 immunostaining was positive in 3 LBs and in 12 out of 16 liposarcomas (10 WDL and 2 ML), with a sensitivity of 75%, a specificity of 90%, a positive predictive value of 80%, and a negative predictive value of 87%. All lipomas were p16 negative, whereas 5 liponecroses were positive. Accounting altogether the benign lesions versus liposarcomas, p16 showed a sensitivity of 75%, a specificity of 87%, a positive predictive value of 60%, and a negative predictive value of 93%. Our data suggest that a negative p16 immunostaining may be helpful in excluding a liposarcoma when occurring in unusual clinical contexts, such as in adolescence or late recurrence. However, such finding should be interpreted with caution since also some liposarcomas lack p16 and occasional LBs are positive. Copyright © 2015 Elsevier Inc. All rights reserved.
Yugué, Itaru; Okada, Seiji; Maeda, Takeshi; Ueta, Takayoshi; Shiba, Keiichiro
2018-04-01
A retrospective study. Precise classification of the neurological state of patients with acute cervical spinal cord injury (CSCI) can be challenging. This study proposed a useful and simple clinical method to help classify patients with incomplete CSCI. Spinal Injuries Centre, Japan. The sensitivity and specificity of the 'knee-up test' were evaluated in patients with acute CSCI classified as American Spinal Injury Association Impairment Scale (AIS) C or D. The result is positive if the patient can lift the knee in one or both legs to an upright position, whereas the result is negative if the patient is unable to lift the knee in either leg to an upright position. The AIS of these patients was classified according to a strict computerised algorithm designed by Walden et al., and the knee-up test was tested by non-expert examiners. Among the 200 patients, 95 and 105 were classified as AIS C and AIS D, respectively. Overall, 126 and 74 patients demonstrated positive and negative results, respectively, when evaluated using the knee-up test. A total of 104 patients with positive results and 73 patients with negative results were classified as AIS D and AIS C, respectively. The sensitivity, specificity, positive predictive and negative predictive values of this test for all patients were 99.1, 76.8, 82.5 and 98.7, respectively. The knee-up test may allow easy and highly accurate estimation, without the need for special skills, of AIS classification for patients with incomplete CSCI.
Urabe, Naohisa; Sakamoto, Susumu; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae
2017-06-01
We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. Copyright © 2017 American Society for Microbiology.
Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung
2017-11-13
The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.
Breath-based biomarkers for tuberculosis
NASA Astrophysics Data System (ADS)
Kolk, Arend H. J.; van Berkel, Joep J. B. N.; Claassens, Mareli M.; Walters, Elisabeth; Kuijper, Sjoukje; Dallinga, Jan W.; van Schooten, Fredrik-Jan
2012-06-01
We investigated the potential of breath analysis by gas chromatography - mass spectrometry (GC-MS) to discriminate between samples collected prospectively from patients with suspected tuberculosis (TB). Samples were obtained in a TB endemic setting in South Africa where 28% of the culture proven TB patients had a Ziehl-Neelsen (ZN) negative sputum smear. A training set of breath samples from 50 sputum culture proven TB patients and 50 culture negative non-TB patients was analyzed by GC-MS. A classification model with 7 compounds resulted in a training set with a sensitivity of 72%, specificity of 86% and accuracy of 79% compared with culture. The classification model was validated with an independent set of breath samples from 21 TB and 50 non-TB patients. A sensitivity of 62%, specificity of 84% and accuracy of 77% was found. We conclude that the 7 volatile organic compounds (VOCs) that discriminate breath samples from TB and non-TB patients in our study population are probably host-response related VOCs and are not derived from the VOCs secreted by M. tuberculosis. It is concluded that at present GC-MS breath analysis is able to differentiate between TB and non-TB breath samples even among patients with a negative ZN sputum smear but a positive culture for M. tuberculosis. Further research is required to improve the sensitivity and specificity before this method can be used in routine laboratories.
Daylami, Rouzbeh; Rogers, Ann M; King, Tonya S; Haluck, Randy S; Shope, Timothy R
2008-01-01
Stricture at the gastrojejunal anastomosis after Roux-en-Y gastric bypass is a significant sequela that often requires intervention. The diagnosis of stricture is usually established by a recognized constellation of symptoms, followed by contrast radiography or endoscopy. The purpose of this report was to evaluate the accuracy of contrast swallow studies in excluding the diagnosis of gastrojejunal stricture. A retrospective analysis of the charts of 119 patients who had undergone laparoscopic Roux-en-Y gastric bypass, representing 41 upper gastrointestinal (GI) swallow studies, was conducted. Of those patients who underwent GI swallow studies, 30 then underwent definitive upper endoscopy to confirm or rule out stricture. The overall sensitivity, specificity, and negative predictive value of the swallow studies were calculated. Of the 30 patients who underwent upper endoscopic examination for symptoms of stricture after laparoscopic gastric bypass, 20 were confirmed to have a stricture. The sensitivity, specificity, and negative predictive value of the upper GI swallow study in this group was 55%, 100%, and 53%, respectively. The demographics of the patients with strictures were similar to those of the study group as a whole. The results of our study have shown that a positive upper GI swallow study is 100% specific for the presence of stricture. However, the sensitivity and negative predictive value of upper GI swallow studies were poor, making this modality unsatisfactory in definitively excluding the diagnosis of gastrojejunal stricture.
El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro
2010-01-01
Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117
Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui
2014-01-01
The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.
Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.
Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad
2012-08-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.
Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders
Kumar, Subodh; Malik, Praveen
2012-01-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165
Kulkarni, M. V.; Zurita, A. N.; Pyka, J. S.; Murray, T. S.; Hodsdon, M. E.
2014-01-01
Resistance to extended-spectrum β-lactam antibiotics has led to a greater reliance upon carbapenems, but the expression of carbapenemases threatens to limit the utility of these drugs. Current methods to detect carbapenemase activity are suboptimal, requiring prolonged incubations during which ineffective therapy may be prescribed. We previously described a sensitive and specific assay for the detection of carbapenemase activity using ertapenem and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this study, we assessed 402 Gram-negative rods, including both Enterobacteriaceae and non-Enterobacteriaceae expressing IMP, VIM, KPC, NDM, and/or OXA carbapenemases, by using imipenem, meropenem, and ertapenem with LC-MS/MS assays. LC-MS/MS methods for the detection of intact and hydrolyzed carbapenems from an enrichment broth were developed. No ion suppression was observed, and the limits of detection for all three drugs were below 0.04 μg/ml. The sensitivity and specificity of meropenem and ertapenem for carbapenemase activity among non-Enterobacteriaceae were low, but imipenem demonstrated a sensitivity and specificity of 96% and 95%, respectively, among all Gram-negative rods (GNR) tested, including both Enterobacteriaceae and non-Enterobacteriaceae. LC-MS/MS allows for the analysis of more complex matrices, and this LC-MS/MS assay could easily be adapted for use with primary specimens requiring growth enrichment. PMID:24789180
Hoang, Laura L; Tacha, David; Bremer, Ryan E; Haas, Thomas S; Cheng, Liang
2015-01-01
Distinguishing between invasive urothelial carcinoma from other genitourinary lesions such as prostatic and renal carcinomas can be difficult, and may require highly sensitive immunohistochemical markers. GATA-binding protein 3 (GATA3) has been reported in a high percentage of urothelial and breast carcinomas. Mouse monoclonal uroplakin II (UPII) and p40 antibodies have recently been developed and demonstrated high specificity in urothelial carcinoma. This study evaluated the immunohistochemical staining sensitivities of UPII, GATA3, p40, and p63 in the detection of invasive urothelial carcinoma. UPII, GATA3, and p40 were further tested for specificity in lung, breast, colon, kidney, and prostate cancers. In all invasive urothelial carcinoma cases, UPII, GATA3, p40, and p63 exhibited sensitivities of 77.7%, 83.5%, 85.4%, and 80.6%, respectively. The combination of UPII, GATA3, and p40 antibodies stained 94.2% (97/103) of all invasive urothelial carcinoma cases, including 92.2% (71/77) of grade 2-3 urothelial carcinomas. In addition, GATA3 and UPII showed negative staining in lung squamous cell carcinomas and p40 showed negative staining in breast infiltrating ductal carcinomas. The combination of UPII, GATA3, and p40 showed negative staining in lung adenocarcinoma, colon adenocarcinoma, and renal carcinomas. In conclusion, UPII, GATA3, and p40, when used in combination, are highly sensitive in the differential diagnosis of invasive urothelial carcinoma.
NASA Astrophysics Data System (ADS)
Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Costas
2011-03-01
Urinary tract infection (UTI) diagnosis requires an overnight culture to identify a sample as positive or negative for a UTI. Additional cultures are required to identify the pathogen responsible for the infection and to test its sensitivity to antibiotics. A rise in ineffective treatments, chronic infections, rising health care costs and antibiotic resistance are some of the consequences of this prolonged waiting period of UTI diagnosis. In this work, Surface Enhanced Raman Spectroscopy (SERS) is used for classifying bacterial samples as positive or negative for UTI. SERS spectra of serial dilutions of E.coli bacteria, isolated from a urine culture, were classified as positive (105-108 cells/ml) or negative (103-104 cells/ml) for UTI after mixing samples with gold nanoparticles. A leave-one-out cross validation was performed using the first two principal components resulting in the correct classification of 82% of all samples. Sensitivity of classification was 88% and specificity was 67%. Antibiotic sensitivity testing was also done using SERS spectra of various species of gram negative bacteria collected 4 hours after exposure to antibiotics. Spectral analysis revealed clear separation between the spectra of samples exposed to ciprofloxacin (sensitive) and amoxicillin (resistant). This study can become the basis for identifying urine samples as positive or negative for a UTI and determining their antibiogram without requiring an overnight culture.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J
2017-03-20
Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.
Cockerill, Patrick A; Rivera, Marcelino E; Krambeck, Amy E
2014-06-01
To define the sensitivity and specificity of stone gram stain for infected urolithiasis treated with percutaneous nephrolithotomy (PCNL). PCNL procedures performed at our institution were analyzed between January 2009 and May 2013. Stone fragments were sent in a sterile fashion for aerobic and fungal cultures. A gram stain and fungal smear were performed on the stones and reported within 24 hours of collection. A total of 228 patients underwent 248 PCNLs. Of the 248 stones, 81 (33%) had a positive stone culture. Stone gram stain was positive in 31 cases and negative in 50. There were 167 negative stone cultures, and in these cases, gram stain was positive in 5 and negative in 162. The calculated sensitivity and specificity of stone gram stain were 38% and 97%. The positive and negative predictive values were 86% and 76%, respectively. In the subset of 16 patients with positive stone fungal cultures, fungal smear was performed in 12 and was positive in 4, giving fungal smear a sensitivity of 33%. The results of this study suggest that stone gram stain cannot be relied on to detect a positive stone culture and may fail to detect up to 62% of infected stones. However, when positive, gram stain accurately predicts a positive stone culture in 86% of cases. Copyright © 2014 Elsevier Inc. All rights reserved.
Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna
2009-10-15
Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu
Murungi, Moses; Fulton, Travis; Reyes, Raquel; Matte, Michael; Ntaro, Moses; Mulogo, Edgar; Nyehangane, Dan; Juliano, Jonathan J; Siedner, Mark J; Boum, Yap; Boyce, Ross M
2017-05-01
Poor specificity may negatively impact rapid diagnostic test (RDT)-based diagnostic strategies for malaria. We performed real-time PCR on a subset of subjects who had undergone diagnostic testing with a multiple-antigen (histidine-rich protein 2 and pan -lactate dehydrogenase pLDH [HRP2/pLDH]) RDT and microscopy. We determined the sensitivity and specificity of the RDT in comparison to results of PCR for the detection of Plasmodium falciparum malaria. We developed and evaluated a two-step algorithm utilizing the multiple-antigen RDT to screen patients, followed by confirmatory microscopy for those individuals with HRP2-positive (HRP2 + )/pLDH-negative (pLDH - ) results. In total, dried blood spots (DBS) were collected from 276 individuals. There were 124 (44.9%) individuals with an HRP2 + /pLDH + result, 94 (34.1%) with an HRP2 + /pLDH - result, and 58 (21%) with a negative RDT result. The sensitivity and specificity of the RDT compared to results with real-time PCR were 99.4% (95% confidence interval [CI], 95.9 to 100.0%) and 46.7% (95% CI, 37.7 to 55.9%), respectively. Of the 94 HRP2 + /pLDH - results, only 32 (34.0%) and 35 (37.2%) were positive by microscopy and PCR, respectively. The sensitivity and specificity of the two-step algorithm compared to results with real-time PCR were 95.5% (95% CI, 90.5 to 98.0%) and 91.0% (95% CI, 84.1 to 95.2), respectively. HRP2 antigen bands demonstrated poor specificity for the diagnosis of malaria compared to that of real-time PCR in a high-transmission setting. The most likely explanation for this finding is the persistence of HRP2 antigenemia following treatment of an acute infection. The two-step diagnostic algorithm utilizing microscopy as a confirmatory test for indeterminate HRP2 + /pLDH - results showed significantly improved specificity with little loss of sensitivity in a high-transmission setting. Copyright © 2017 American Society for Microbiology.
Wardell, Jeffrey D; Quilty, Lena C; Hendershot, Christian S; Bagby, R Michael
2015-12-01
Motives for gambling have been shown to have an important role in gambling behavior, consistent with the literature on motives for substance use. While studies have demonstrated that traits related to sensitivity to reward (SR) and sensitivity to punishment (SP) are predictive of substance use motives, little research has examined the role of these traits in gambling motives. This study investigated motivational pathways from SR and SP to gambling frequency and gambling problems via specific gambling motives, while also taking into account history of substance use disorder (SUD). A community sample of gamblers (N = 248) completed self-report questionnaires assessing SR, SP, gambling frequency, gambling-related problems, and motives for gambling (social, negative affect, and enhancement/winning motives). Lifetime SUD was also assessed with a structured clinical interview. The results of a path analysis showed that SR was uniquely associated with all 3 types of gambling motives, whereas SP and SUD were associated with negative affect and enhancement/winning motives but not social motives. Also, both negative affect and enhancement/winning motives were associated with gambling problems, but only enhancement/winning motives were significantly related to gambling frequency. Analyses of indirect associations revealed significant indirect associations from SR, SP, and SUD to gambling frequency mediated through enhancement/winning motives and to gambling problems mediated through both negative affect and enhancement/winning motives. The findings highlight the importance of SR and SP as independent predictors of gambling motives and suggest that specific motivational pathways underlie their associations with gambling outcomes. (c) 2016 APA, all rights reserved).
Rosenthal, Eben L; Moore, Lindsay S; Tipirneni, Kiranya; de Boer, Esther; Stevens, Todd M; Hartman, Yolanda E; Carroll, William R; Zinn, Kurt R; Warram, Jason M
2017-08-15
Purpose: Comprehensive cervical lymphadenectomy can be associated with significant morbidity and poor quality of life. This study evaluated the sensitivity and specificity of cetuximab-IRDye800CW to identify metastatic disease in patients with head and neck cancer. Experimental Design: Consenting patients scheduled for curative resection were enrolled in a clinical trial to evaluate the safety and specificity of cetuximab-IRDye800CW. Patients ( n = 12) received escalating doses of the study drug. Where indicated, cervical lymphadenectomy accompanied primary tumor resection, which occurred 3 to 7 days following intravenous infusion of cetuximab-IRDye800CW. All 471 dissected lymph nodes were imaged with a closed-field, near-infrared imaging device during gross processing of the fresh specimens. Intraoperative imaging of exposed neck levels was performed with an open-field fluorescence imaging device. Blinded assessments of the fluorescence data were compared to histopathology to calculate sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV). Results: Of the 35 nodes diagnosed pathologically positive, 34 were correctly identified with fluorescence imaging, yielding a sensitivity of 97.2%. Of the 435 pathologically negative nodes, 401 were correctly assessed using fluorescence imaging, yielding a specificity of 92.7%. The NPV was determined to be 99.7%, and the PPV was 50.7%. When 37 fluorescently false-positive nodes were sectioned deeper (1 mm) into their respective blocks, metastatic cancer was found in 8.1% of the recut nodal specimens, which altered staging in two of those cases. Conclusions: Fluorescence imaging of lymph nodes after systemic cetuximab-IRDye800CW administration demonstrated high sensitivity and was capable of identifying additional positive nodes on deep sectioning. Clin Cancer Res; 23(16); 4744-52. ©2017 AACR . ©2017 American Association for Cancer Research.
Exfoliative cytology: a helpful tool for the diagnosis of paracoccidioidomycosis.
Cardoso, S V; Moreti, M M; Costa, I M; Loyola, A M
2001-07-01
To describe the main cytological findings associated with smears collected from oral lesions of paracoccidioidomycosis and to appraise the use of cytology as a diagnostic tool for the disease. Cytological smears and biopsies were collected from 40 lesions with a clinical suspicion of paracoccidioidomycosis. Evaluation of the sensitivity, specificity, positive and negative predictive values, accuracy and the positive likeness ratio of the oral smear when compared with the histological diagnosis, was performed. The latter is considered the 'gold standard' for comparison. The main morphological findings were the rounded-shaped, birefringent and multiple-budded fungi, Langhans' giant cells and epithelioid cells. The following associative measures were found: sensitivity, 67.9%; specificity, 91.7%; positive predictive value, 95.0%; negative predictive value, 55.0%; accuracy, 75.0%; and positive likeness ratio, 8.14. The cytological findings of paracoccidioidomycosis are characteristic and cytology is accurate in the diagnosis of the disease. Positive patients should be treated. Negative patients should be submitted to biopsy to confirm or to dismiss the diagnosis of this mycosis.
Qian, Xiaohua; Hecht, Jonathan L
2003-01-01
To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.
A Sensitive and Specific Neural Signature for Picture-Induced Negative Affect
Chang, Luke J.; Gianaros, Peter J.; Manuck, Stephen B.; Krishnan, Anjali; Wager, Tor D.
2015-01-01
Neuroimaging has identified many correlates of emotion but has not yet yielded brain representations predictive of the intensity of emotional experiences in individuals. We used machine learning to identify a sensitive and specific signature of emotional responses to aversive images. This signature predicted the intensity of negative emotion in individual participants in cross validation (n =121) and test (n = 61) samples (high–low emotion = 93.5% accuracy). It was unresponsive to physical pain (emotion–pain = 92% discriminative accuracy), demonstrating that it is not a representation of generalized arousal or salience. The signature was comprised of mesoscale patterns spanning multiple cortical and subcortical systems, with no single system necessary or sufficient for predicting experience. Furthermore, it was not reducible to activity in traditional “emotion-related” regions (e.g., amygdala, insula) or resting-state networks (e.g., “salience,” “default mode”). Overall, this work identifies differentiable neural components of negative emotion and pain, providing a basis for new, brain-based taxonomies of affective processes. PMID:26098873
Sakane, Makoto; Hori, Masatoshi; Onishi, Hiromitsu; Tsuboyama, Takahiro; Ota, Takashi; Tatsumi, Mitsuaki; Ueda, Yutaka; Kimura, Toshihiro; Kimura, Tadashi; Tomiyama, Noriyuki
The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.
Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers
2015-01-01
Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. PMID:26109105
Hoppin, Jane A.; Jaramillo, Renee; Salo, Paivi; Sandler, Dale P.; London, Stephanie J.; Zeldin, Darryl C.
2011-01-01
Allergic conditions and biochemical measures are both used to characterize atopy. To assess questionnaires’ ability to predict biochemical measures of atopy, the authors used data on 5 allergic conditions (allergy, hay fever, eczema, rhinitis, and itchy rash) and serum-specific immunoglobulin E (IgE) levels from the 2005–2006 National Health and Nutrition Examination Survey. Atopy was defined as 1 or more positive specific IgEs (≥0.35 kU/L). Questionnaire responses were assessed for sensitivity, specificity, and positive and negative predictive values for atopy. In this population-based US sample, 44% of participants were specific IgE-positive and 53% reported at least 1 allergic condition. Discordance between atopy and allergic conditions was considerable; 37% of persons with atopy reported no allergic condition, and 48% of persons who reported an allergic condition were not atopic. Thus, no combination of self-reported allergic conditions achieved both high sensitivity and high specificity for IgE. The positive predictive value of reported allergic conditions for atopy ranged from 50% for eczema to 72% for hay fever, while the negative predictive value ranged from 57% for eczema to 65% for any condition. Given the high proportion of asymptomatic participants who were specific IgE-positive and persons who reported allergic conditions but were specific IgE-negative, it is unlikely that questionnaires will ever capture the same participants as those found to be atopic by biochemical measures. PMID:21273397
Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada
2002-08-01
The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.
How to use … the Monospot and other heterophile antibody tests.
Marshall-Andon, Tess; Heinz, Peter
2017-08-01
Epstein-Barr virus (EBV) is a highly prevalent virus, transmitted via saliva, which often causes asymptomatic infection in children but frequently results in infectious mononucleosis in adolescents. Heterophile antibody tests, including the Monospot test, are red cell or latex agglutination assays, which detect antired cell antibodies produced as part of a polyclonal antibody response occurring during EBV infection. Heterophile antibody tests are rapid, cheap and specific tests that can be performed from the onset of symptoms of infectious mononucleosis. In adolescents, heterophile antibody tests have high specificity and sensitivity in the diagnosis of primary acute EBV infection. However, the tests have low sensitivity and low negative predictive value in young children and are not useful under the age of 4. Heterophile tests may be positive in other viral infections, autoimmune disease and haematological malignancies, but do not appear to be positive in primary bacterial infection. Virus-specific serology is required in children under the age of 4 or if an older child is heterophile negative. Virus-specific serology allows diagnosis and the pattern of positivity and negativity enables the clinician to stage the EBV infection. Virus-specific serology appears to have better sensitivity in young children, but there is cross-reaction with other herpesvirus infections, a longer turnaround time and it is more expensive to perform. Further research is needed to establish which children benefit from and hence require testing for heterophile antibodies, the cost-effectiveness of EBV investigations and whether heterophile titres have predictive value for the severity of infection and the likelihood of complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth
2018-06-01
The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.
Tadesse, Mulualem; Aragaw, Dossegnaw; Rigouts, Leen; Abebe, Gemeda
2016-06-01
The GeneXpert MTB/RIF assay (Xpert) was endorsed as the initial diagnostic tool in people suspected of human immunodeficiency virus-associated or drug-resistant tuberculosis (TB). However, information regarding the performance of Xpert for diagnosing smear-negative TB in high burden settings remains limited. We evaluated the diagnostic accuracy of Xpert and the impact of bleach concentration on the performance of Xpert using smear-negative sputum samples from human immunodeficiency virus-negative patients. One spot and one morning smear-negative sputum samples per patient were examined using Xpert and culture at the Mycobacteriology Research Center of Jimma University, Ethiopia. The sputum culture on both Löwenstein-Jensen and/or Mycobacteria Growth Indicator Tube was the gold-standard. Of 185 smear-negative presumptive pulmonary TB cases, 19 (10.3%) had culture-proven TB. The sensitivity of Xpert on spot and morning sputum was similar (63.2%). Testing two specimens per patient insignificantly increased the sensitivity of Xpert. Bleach concentration and pelleting improved the sensitivity of Xpert over unprocessed sputum in paired samples (73.8% vs. 63.2%) without affecting the specificity (95%). Bleach concentration and pelleting allowed an additional seven cases of TB (missed on the first and second direct Xperts) to be detected, five of which were from culture-negative cases. Testing of a single sputum sample by Xpert can reach reasonable sensitivity and results would be available on the same day, avoiding loss of patients and treatment delay. The sensitivity of Xpert was improved after bleach concentration and pelleting, although its added value needs further study on a larger scale. Copyright © 2016 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.
Can missed breast cancer be recognized by regular peer auditing on screening mammography?
Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai
2012-09-01
This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of < 0.05 was considered significant. Eight (6 traditional and 2 digital films) of the 176 false negative films were not reported by the auditors (missing rate of 4.5%). Of this total, 87 false negatives were reassessed as positive, while 29 of the 186 true negatives were reassessed as positive, making the overall performance of the 34 auditors in interpreting the false negatives and true negatives a specificity of 84.4% and sensitivity of 51.8%. The specificity and sensitivity in traditional films and laser-printed films were 98.6% versus 43.8% and 41.8% versus 78.3%, respectively. Almost 42% of the traditional false negative films had positive reassessment by the auditors, showing a significant difference from the initial screeners (p < 0.001). The specificity of their reinterpretation of laser-printed films was obviously low. Almost 42% of the false negative traditional films were judged as missed cancers in this study. A peer auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V
Shinto, Ajit S.; Kamaleshwaran, K. K.; Mallia, Madhav; Korde, Aruna; Samuel, Grace; Banerjee, Sharmila; Velayutham, Pavanasam; Damodharan, Suresh; Sairam, Madhu
2015-01-01
Several studies have reported on the expression of somatostatin receptors (SSTRs) in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed Technetium-99m labeled somatostatin analog, 99mTc-Hynic-TOC, in terms of precise localization of the disease. The study population consisted of 28 patients (16 men, 12 women; age range: 39-72 years) with histologically confirmed DTC, who presented with recurrent or persistent disease as indicated by elevated serum thyroglobulin (Tg) levels after initial treatment (serum Tg > 10 ng/ml off T4 suppression for 4-6 weeks). All patients were negative on the Iodine-131 posttherapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) was performed in all patients. SSTR scintigraphy was true positive in 23 cases (82.1%), true negative in two cases (7.1%) and false negative in three cases (10.7%) which resulted in a sensitivity of 88.46%, specificity of 100% and an accuracy of 89.2%. Sensitivity of 99mTc-Hynic-TOC scan was higher (93.7%) for patients with advanced stages, that is stages III and IV. 18F-FDG showed a sensitivity of 93.7%, a specificity of 50% and an accuracy of 89.3%. 18F-FDG PET was found to be more sensitive, with lower specificity due to false positive results in 2 patients. Analysis on a lesion basis demonstrated substantial agreement between the two imaging techniques with a Cohen's kappa of 0.66. Scintigraphy with 99mTc-Hynic-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localization diagnostics in thyroid cancer patients with recurrent or metastatic disease. PMID:26097420
Shinto, Ajit S; Kamaleshwaran, K K; Mallia, Madhav; Korde, Aruna; Samuel, Grace; Banerjee, Sharmila; Velayutham, Pavanasam; Damodharan, Suresh; Sairam, Madhu
2015-01-01
Several studies have reported on the expression of somatostatin receptors (SSTRs) in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed Technetium-99m labeled somatostatin analog, (99m)Tc-Hynic-TOC, in terms of precise localization of the disease. The study population consisted of 28 patients (16 men, 12 women; age range: 39-72 years) with histologically confirmed DTC, who presented with recurrent or persistent disease as indicated by elevated serum thyroglobulin (Tg) levels after initial treatment (serum Tg > 10 ng/ml off T4 suppression for 4-6 weeks). All patients were negative on the Iodine-131 posttherapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in all patients. SSTR scintigraphy was true positive in 23 cases (82.1%), true negative in two cases (7.1%) and false negative in three cases (10.7%) which resulted in a sensitivity of 88.46%, specificity of 100% and an accuracy of 89.2%. Sensitivity of (99m)Tc-Hynic-TOC scan was higher (93.7%) for patients with advanced stages, that is stages III and IV. (18)F-FDG showed a sensitivity of 93.7%, a specificity of 50% and an accuracy of 89.3%. (18)F-FDG PET was found to be more sensitive, with lower specificity due to false positive results in 2 patients. Analysis on a lesion basis demonstrated substantial agreement between the two imaging techniques with a Cohen's kappa of 0.66. Scintigraphy with (99m)Tc-Hynic-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localization diagnostics in thyroid cancer patients with recurrent or metastatic disease.
Can We Rule Out Meningitis from Negative Jolt Accentuation? A Retrospective Cohort Study.
Sato, Ryota; Kuriyama, Akira; Luthe, Sarah Kyuragi
2017-04-01
Jolt accentuation has been considered to be the most sensitive physical finding to predict meningitis. However, there are only a few studies assessing the diagnostic accuracy of jolt accentuation. Therefore, we aimed to evaluate the diagnostic accuracy of jolt accentuation and investigate whether it can be extended to patients with mild altered mental status. We performed a single center, retrospective observational study on patients who presented to the emergency department in a Japanese tertiary care center from January 1, 2010 to March 31, 2016. Jolt accentuation evaluated in patients with fever, headache, and mild altered mental status with Glasgow Coma Scale no lower than E2 or M4 was defined as "jolt accentuation in the broad sense." Jolt accentuation evaluated in patients with fever, headache, and no altered mental status was defined as "jolt accentuation in the narrow sense." We evaluated the sensitivity and specificity in both groups. Among 118 patients, the sensitivity and specificity of jolt accentuation in the broad sense were 70.7% (95% confidence interval (CI): 58.0%-80.8%) and 36.7% (95% CI: 25.6%-49.3%). The positive likelihood ratio and negative likelihood ratio were 1.12 (95% CI: 0.87-1.44) and 0.80 (95% CI: 0.48-1.34), respectively. Among 108 patients, the sensitivity and specificity of jot accentuation in the narrow sense were 75.0% (95% CI: 61.8%-84.8%) and 35.1% (95% CI: 24.0%-48.0%). The positive likelihood ratio and negative likelihood ratio were 1.16 (95% CI: 0.90-1.48) and 0.71 (95% CI: 0.40-1.28), respectively. Jolt accentuation itself has a limited value in the diagnosis of meningitis regardless of altered mental status. Therefore, meningitis should not be ruled out by negative jolt accentuation. © 2017 American Headache Society.
Rupprecht, Elizabeth A; Kueny, Clair Reynolds; Shoss, Mindy K; Metzger, Andrew J
2016-10-01
We challenge the intuitive belief that greater leader sensitivity is always associated with desirable outcomes for employees and organizations. Specifically, we argue that followers' idiosyncratic desires for, and perceptions of, leader sensitivity behaviors play a key role in how followers react to their leader's sensitivity. Moreover, these resulting affective experiences are likely to have important consequences for organizations, specifically as they relate to employee counterproductive work behavior (CWB). Drawing from supplies-values (S-V) fit theory and the stressor-emotion model of CWB, the current study focuses on the affective and behavioral consequences of fit between subordinates' ideal leader sensitivity behavior preferences and subordinates' perceptions of their actual leader's sensitivity behaviors. Polynomial regression analyses reveal that congruence between ideal and actual leader sensitivity influences employee negative affect and, consequently, engagement in counterproductive work behavior. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Pennick, Kate E; McKnight, Christy A; Patterson, Jon S; Latimer, Kenneth S; Maes, Roger K; Wise, Annabel G; Kiupel, Matti
2012-03-01
Immunohistochemistry (IHC) and in situ hybridization (ISH) can be used either to detect or to differentiate between Eastern equine encephalitis virus (EEEV) and West Nile virus (WNV) within formalin-fixed, paraffin-embedded (FFPE) brain tissue of horses. To compare the diagnostic sensitivity and specificity of ISH and IHC, FFPE brain tissue from 20 EEEV-positive horses and 16 WNV-positive horses were tested with both EEEV and WNV oligoprobes and EEEV- and WNV-specific antibodies. Reverse transcription polymerase chain reaction (RT-PCR) for detection of EEEV and WNV was used as the gold standard to confirm infection. All horses that tested positive for EEEV by RT-PCR also tested positive by IHC and ISH, except for 1 case that was false-negative by ISH. In contrast, all horses that tested positive for WNV by RT-PCR tested negative by IHC and only 2 horses tested positive by ISH. No false-positives were detected with either method for both viruses. Both IHC and ISH are highly specific and sensitive diagnostic methods to detect EEEV in equine FFPE brain tissues, although neither appear effective for the diagnosis of WNV in equine neurologic cases.
Hinton, Devon E; Lewis-Fernández, Roberto; Pollack, Mark H
2009-01-01
This article examines a model of the generation of ataque de nervios, according to which both fear of negative affectivity and fear of arousal symptoms are associated with the emergence of ataques. We examine the relationship of fear of negative affectivity and fear of arousal to the severity of ataque de nervios during the last month and the last 6 months among Caribbean Latinos residing in the United States. The measures include a Fear of Anger Scale and the Anxiety Sensitivity Index (ASI), the ASI augmented with two items that assess fear of arousal symptoms common in ataques: chest tightness and a sense of inner heat. In keeping with the model of ataque generation, one-way analysis of variances (ANOVAs) and discriminant function analyses illustrated that items assessing "fear of negative affect" and "fear of somatic and psychological symptoms of arousal" both differentiated well among the levels of ataque severity. In addition, key ataque symptoms-mental incapacitation fears, shakiness, chest tightness, palpitations, and a sense of inner heat-were the best discriminators among levels of ataque severity. In patients with severe ataques, the scores of "fear of negative affect" and "fear of ataque-de-nervios-type somatic and psychological symptoms" were extremely elevated. This further suggests that both these types of fears are associated with this idiom of distress and that the specific content of the fears is linked to the symptom picture of the idiom. This suggests specific therapeutic targets for the treatment of ataque, namely, the reduction of anxiety sensitivity (and more generally negative-emotion and arousal sensitivity) using cognitive behavioral therapy (CBT), relaxation, and mindfulness techniques.
Prefrontal Neural Activity When Feedback Is Not Relevant to Adjust Performance
Özyurt, Jale; Rietze, Mareike; Thiel, Christiane M.
2012-01-01
It has been shown that the rostral cingulate zone (RCZ) in humans uses both positive and negative feedback to evaluate performance and to flexibly adjust behaviour. Less is known on how the feedback types are processed by the RCZ and other prefrontal brain areas, when feedback can only be used to evaluate performance, but cannot be used to adjust behaviour. The present fMRI study aimed at investigating feedback that can only be used to evaluate performance in a word-learning paradigm. One group of volunteers (N = 17) received informative, performance-dependent positive or negative feedback after each trial. Since new words had to be learnt in each trial, the feedback could not be used for task-specific adaptations. The other group (N = 17) always received non-informative feedback, providing neither information about performance nor about possible task-specific adaptations. Effects of the informational value of feedback were assessed between-subjects, comparing trials with positive and negative informative feedback to non-informative feedback. Effects of feedback valence were assessed by comparing neural activity to positive and negative feedback within the informative-feedback group. Our results show that several prefrontal regions, including the pre-SMA, the inferior frontal cortex and the insula were sensitive to both, the informational value and the valence aspect of the feedback with stronger activations to informative as compared to non-informative feedback and to informative negative compared to informative positive feedback. The only exception was RCZ which was sensitive to the informational value of the feedback, but not to feedback valence. The findings indicate that outcome information per se is sufficient to activate prefrontal brain regions, with the RCZ being the only prefrontal brain region which is equally sensitive to positive and negative feedback. PMID:22615774
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
Shao, Yan; Peng, Hong; Chen, Cheng; Zhu, Tao; Ji, Ming; Jiang, Wei; Zhu, Wei; Zhai, Xiang Jun; Lu, Wei
2017-04-01
Tuberculosis is one of the most common infectious diseases in China, while delayed patient finding obstructed disease control, especially for smear-negative patients. The current study was undertaken to evaluate the diagnostic accuracy of GeneXpert MTB/RIF compared with conventional methods in the detection of pulmonary tuberculosis patients. A total of 295 spot sputum samples from confirmed pulmonary tuberculosis patients were evaluated from September 2014 to June 2015. Each sample was examined by acid-fast bacillus smear microscopy, culture and GeneXpert MTB/RIF. The sputum culture on Löwenstein-Jensen (L-J) was considered as the gold-standard. After testing by smear, 68.81% (203/295) was negative and 31.19% (92/295) was positive. As the gold-standard, L-J culture detected 37.97% (112/295) positive of all specimens, while the positivity for GeneXpert MTB/RIF was 46.44% (137/295). Compared with L-J culture, the combined sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for GeneXpert MTB/RIF were 94.64%, 82.97%, 77.37% and 96.18% respectively. For smear-negative specimens, the sensitivity, specificity, PPV and NPV for GeneXpert MTB/RIF were 96.00%, 83.05%, 44.44% and 99.32%; while for smear-positive specimens, the corresponding accuracy values were 94.25%, 80.00%, 98.80% and 44.44%. The findings of study indicated that GeneXpert MTB/RIF assay demonstrated a high sensitivity in detecting Mycobacterium tuberculosis compared to smear method and a high NPV among smear negative patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
Application of Immunosignatures for Diagnosis of Valley Fever
Navalkar, Krupa Arun; Johnston, Stephen Albert; Woodbury, Neal; Galgiani, John N.; Magee, D. Mitchell; Chicacz, Zbigniew
2014-01-01
Valley fever (VF) is difficult to diagnose, partly because the symptoms of VF are confounded with those of other community-acquired pneumonias. Confirmatory diagnostics detect IgM and IgG antibodies against coccidioidal antigens via immunodiffusion (ID). The false-negative rate can be as high as 50% to 70%, with 5% of symptomatic patients never showing detectable antibody levels. In this study, we tested whether the immunosignature diagnostic can resolve VF false negatives. An immunosignature is the pattern of antibody binding to random-sequence peptides on a peptide microarray. A 10,000-peptide microarray was first used to determine whether valley fever patients can be distinguished from 3 other cohorts with similar infections. After determining the VF-specific peptides, a small 96-peptide diagnostic array was created and tested. The performances of the 10,000-peptide array and the 96-peptide diagnostic array were compared to that of the ID diagnostic standard. The 10,000-peptide microarray classified the VF samples from the other 3 infections with 98% accuracy. It also classified VF false-negative patients with 100% sensitivity in a blinded test set versus 28% sensitivity for ID. The immunosignature microarray has potential for simultaneously distinguishing valley fever patients from those with other fungal or bacterial infections. The same 10,000-peptide array can diagnose VF false-negative patients with 100% sensitivity. The smaller 96-peptide diagnostic array was less specific for diagnosing false negatives. We conclude that the performance of the immunosignature diagnostic exceeds that of the existing standard, and the immunosignature can distinguish related infections and might be used in lieu of existing diagnostics. PMID:24964807
Nested PCR for specific diagnosis of Taenia solium taeniasis.
Mayta, Holger; Gilman, Robert H; Prendergast, Emily; Castillo, Janeth P; Tinoco, Yeny O; Garcia, Hector H; Gonzalez, Armando E; Sterling, Charles R
2008-01-01
Taeniasis due to Taenia solium is a disease with important public health consequences, since the larval stage is not exclusive to the animal intermediate, the pig, but also infects humans, causing neurocysticercosis. Early diagnosis and treatment of T. solium tapeworm carriers is important to prevent human cysticercosis. Current diagnosis based on microscopic observation of eggs lacks both sensitivity and specificity. In the present study, a nested-PCR assay targeting the Tso31 gene was developed for the specific diagnosis of taeniasis due to T. solium. Initial specificity and sensitivity testing was performed using stored known T. solium-positive and -negative samples. The assay was further analyzed under field conditions by conducting a case-control study of pretreatment stool samples collected from a population in an area of endemicity. Using the archived samples, the assay showed 97% (31/32) sensitivity and 100% (123/123) specificity. Under field conditions, the assay had 100% sensitivity and specificity using microscopy/enzyme-linked immunosorbent assay coproantigen testing as the gold standards. The Tso31 nested PCR described here might be a useful tool for the early diagnosis and prevention of taeniasis/cysticercosis.
Development of a species-specific coproantigen ELISA for human Taenia solium taeniasis.
Guezala, Maria-Claudia; Rodriguez, Silvia; Zamora, Humberto; Garcia, Hector H; Gonzalez, Armando E; Tembo, Alice; Allan, James C; Craig, Philip S
2009-09-01
Taenia solium causes human neurocysticercosis and is endemic in underdeveloped countries where backyard pig keeping is common. Microscopic fecal diagnostic methods for human T. solium taeniasis are not very sensitive, and Taenia saginata and Taenia solium eggs are indistinguishable under the light microscope. Coproantigen (CoAg) ELISA methods are very sensitive, but currently only genus (Taenia) specific. This paper describes the development of a highly species-specific coproantigen ELISA test to detect T. solium intestinal taeniasis. Sensitivity was maintained using a capture antibody of rabbit IgG against T. solium adult whole worm somatic extract, whereas species specificity was achieved by utilization of an enzyme-conjugated rabbit IgG against T. solium adult excretory-secretory (ES) antigen. A known panel of positive and negative human fecal samples was tested with this hybrid sandwich ELISA. The ELISA test gave 100% specificity and 96.4% sensitivity for T. solium tapeworm carriers (N = 28), with a J index of 0.96. This simple ELISA incorporating anti-adult somatic and anti-adult ES antibodies provides the first potentially species-specific coproantigen test for human T. solium taeniasis.
Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J
2016-02-01
To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Husain, Shahid; Kwak, Eun Jeong; Obman, Asia; Wagener, Marilyn M; Kusne, Shimon; Stout, Janet E; McCurry, Kenneth R; Singh, Nina
2004-05-01
The clinical utility of Platelia trade mark Aspergillus galactomannan antigen for the early diagnosis of invasive aspergillosis was prospectively assessed in 70 consecutive lung transplant recipients. Sera were collected twice weekly and tested for galactomannan. Invasive aspergillosis was documented in 17.1% (12/70) of the patients. Using the generalized estimating equation model, at the cutoff value of >or= 0.5, the sensitivity of the test was 30%, specificity 93% with positive and negative likelihood ratios of 4.2 and 0.75, respectively. Increasing the cutoff value to >or= 0.66 yielded a sensitivity of 30%, specificity of 95%, and positive and negative likelihood ratios of 5.5 and 0.74. A total of 14 patients had false-positive tests, including nine who had cystic fibrosis or chronic obstructive pulmonary disease. False-positive tests occurred within 3 days of transplantation in 43% (6/14) of the patients, and within 7 days in 64% (9/14). Thus, the test demonstrated excellent specificity, but a low sensitivity for the diagnosis of aspergillosis in this patient population. Patients with cystic fibrosis or chronic obstructive pulmonary disease may transiently have a positive test in the early post-transplant period.
Rice, Jason P; Seifert, Marva; Moser, Kathleen S; Rodwell, Timothy C
2017-01-01
Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected from suspect pulmonary TB patients over a 4-year time period in San Diego County, California. Xpert MTB/RIF results were compared to acid-fast bacilli (AFB) smear microscopy, mycobacterial culture, and phenotypic drug susceptibility testing (DST). Of 751 sputum specimens, 134 (17.8%) were MTBC culture-positive and 2 (1.5%) were multidrug-resistant (MDR). For the detection of MTBC, Xpert MTB/RIF sensitivity was 89.6% (97.7% and 74.5% in smear-positive and -negative sputa, respectively) and specificity was 97.2%; while AFB smear sensitivity and specificity were 64.9% and 77.8%, respectively. Xpert MTB/RIF detected 35 of 47 smear-negative culture-positive specimens, and excluded 124 of 137 smear-positive culture-negative specimens. Xpert MTB/RIF also correctly excluded 99.2% (121/122) of nontuberculous mycobacteria (NTM) specimens, including all 33 NTM false-positives by smear microscopy. For the detection of RIF resistance, Xpert MTB/RIF sensitivity and specificity were 100% and 98.3%, respectively. Our findings demonstrate that Xpert MTB/RIF is able to accurately detect MTBC and RIF resistance in routinely collected respiratory specimens in a low TB-incidence setting, with comparable performance to that achieved in high-incidence settings; and suggest that under these conditions the assay has particular utility in detecting smear-negative TB cases, excluding smear-positive patients without MTBC disease, and differentiating MTBC from NTM.
Rice, Jason P.; Moser, Kathleen S.; Rodwell, Timothy C.
2017-01-01
Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected from suspect pulmonary TB patients over a 4-year time period in San Diego County, California. Xpert MTB/RIF results were compared to acid-fast bacilli (AFB) smear microscopy, mycobacterial culture, and phenotypic drug susceptibility testing (DST). Of 751 sputum specimens, 134 (17.8%) were MTBC culture-positive and 2 (1.5%) were multidrug-resistant (MDR). For the detection of MTBC, Xpert MTB/RIF sensitivity was 89.6% (97.7% and 74.5% in smear-positive and -negative sputa, respectively) and specificity was 97.2%; while AFB smear sensitivity and specificity were 64.9% and 77.8%, respectively. Xpert MTB/RIF detected 35 of 47 smear-negative culture-positive specimens, and excluded 124 of 137 smear-positive culture-negative specimens. Xpert MTB/RIF also correctly excluded 99.2% (121/122) of nontuberculous mycobacteria (NTM) specimens, including all 33 NTM false-positives by smear microscopy. For the detection of RIF resistance, Xpert MTB/RIF sensitivity and specificity were 100% and 98.3%, respectively. Our findings demonstrate that Xpert MTB/RIF is able to accurately detect MTBC and RIF resistance in routinely collected respiratory specimens in a low TB-incidence setting, with comparable performance to that achieved in high-incidence settings; and suggest that under these conditions the assay has particular utility in detecting smear-negative TB cases, excluding smear-positive patients without MTBC disease, and differentiating MTBC from NTM. PMID:29016684
Periprosthetic infection: where do we stand with regard to Gram stain?
Ghanem, Elie; Ketonis, Constantinos; Restrepo, Camilo; Joshi, Ashish; Barrack, Robert
2009-01-01
Background and purpose One of the routinely used intraoperative tests for diagnosis of periprosthetic infection (PPI) is the Gram stain. It is not known if the result of this test can vary according to the type of joint affected or the number of specimen samples collected. We examined the role of this diagnostic test in a large cohort of patients from a single institution. Materials and methods A positive gram stain was defined as the visualization of bacterial cells or “many neutrophils” (> 5 per high-power field) in the smear. The sensitivity, specificity, and predictive values of each individual diagnostic arm of Gram stain were determined. Combinations were performed in series, which required both tests to be positive to confirm infection, and also in parallel, which necessitated both tests to be negative to rule out infection. Results The presence of organisms and “many” neutrophils on a Gram smear had high specificity (98–100%) and positive predictive value (89–100%) in both THA and TKA. The sensitivities (30–50%) and negative predictive values (70–79%) of the 2 tests were low for both joint types. When the 2 tests were combined in series, the specificity and positive predictive value were absolute (100%). The sensitivity and the negative predictive value improved for both THA and TKA (43–64% and 82%, respectively). Interpretation Although the 2 diagnostic arms of Gram staining can be combined to achieve improved negative predictive value (82%), Gram stain continues to have little value in ruling out PPI. With the advances in the field of molecular biology, novel diagnostic modalities need to be designed that can replace these traditional and poor tests. PMID:19297787
Apirakviriya, Chayanis; Rungruxsirivorn, Tassawan; Phupong, Vorapong; Wisawasukmongchol, Wirach
2016-05-01
To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.
Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A
2013-12-01
With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.
Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony
2015-01-01
This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Ibekwe, Titus S.; Nwegbu, Maxwell M.; Asogun, Daniel; Adomeh, Donatus I.; Okokhere, Peter O.
2012-01-01
Background: Early diagnosis, prompt treatment, and disease containment are vital measures in the management of Lassa fever (LF), a lethal and contagious arenaviral hemorrhagic disease prevalent in West Africa. Lassa Virus (LAV)-specific Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) test, the gold standard for diagnosis, is unavailable in most centers. Serologic detection of LAV IgM is a more accessible tool and this work was to investigate its adequacy as an early marker for LF. Patients and Methods: A prospective case–control study conducted July 2007-March 2011 in a tertiary referral health center in Nigeria. Blood samples for test and control were evaluated for Lassa specific antigens and IgM using RT-PCR (primers S36+ and LVS 339) and indirect ELISA (Lassa Nucleo-protein (NP)-Antigen) respectively. RT-PCR outcome was used as standard to test for the sensitivity and specificity of IgM. Results: Of the 37 confirmed cases of LF infection by RT-PCR, 21 (57%) were IgM positive. Amongst the 35 confirmed negative cases (control group), eight were IgM positive. The diagnostic sensitivity and specificity of the IgM assay were 57% and 77% respectively. The negative and positive predictive values of the IgM serological assay were 63% and 72%, respectively, while the efficiency of the test was 67%. Conclusion: The specificity and sensitivity of IgM as a screening tool for early detection of LF appear weak and, hence, the need for a reliable LF “rapid screening kit” since RT-PCR is unavailable in most centers. In the interim, “high clinical index of suspicion,” irrespective of IgM status, requires urgent referral to confirmatory centers. PMID:23661877
Ibekwe, Titus S; Nwegbu, Maxwell M; Asogun, Daniel; Adomeh, Donatus I; Okokhere, Peter O
2012-10-01
Early diagnosis, prompt treatment, and disease containment are vital measures in the management of Lassa fever (LF), a lethal and contagious arenaviral hemorrhagic disease prevalent in West Africa. Lassa Virus (LAV)-specific Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) test, the gold standard for diagnosis, is unavailable in most centers. Serologic detection of LAV IgM is a more accessible tool and this work was to investigate its adequacy as an early marker for LF. A prospective case-control study conducted July 2007-March 2011 in a tertiary referral health center in Nigeria. Blood samples for test and control were evaluated for Lassa specific antigens and IgM using RT-PCR (primers S36+ and LVS 339) and indirect ELISA (Lassa Nucleo-protein (NP)-Antigen) respectively. RT-PCR outcome was used as standard to test for the sensitivity and specificity of IgM. Of the 37 confirmed cases of LF infection by RT-PCR, 21 (57%) were IgM positive. Amongst the 35 confirmed negative cases (control group), eight were IgM positive. The diagnostic sensitivity and specificity of the IgM assay were 57% and 77% respectively. The negative and positive predictive values of the IgM serological assay were 63% and 72%, respectively, while the efficiency of the test was 67%. The specificity and sensitivity of IgM as a screening tool for early detection of LF appear weak and, hence, the need for a reliable LF "rapid screening kit" since RT-PCR is unavailable in most centers. In the interim, "high clinical index of suspicion," irrespective of IgM status, requires urgent referral to confirmatory centers.
Felten, Sandra; Leutenegger, Christian M; Balzer, Hans-Joerg; Pantchev, Nikola; Matiasek, Kaspar; Wess, Gerhard; Egberink, Herman; Hartmann, Katrin
2017-08-02
Feline coronavirus (FCoV) exists as two pathotypes, and FCoV spike gene mutations are considered responsible for the pathotypic switch in feline infectious peritonitis (FIP) pathogenesis. The aim of this study was to evaluate sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (RT-PCR) specifically designed to detect FCoV spike gene mutations at two nucleotide positions. It was hypothesized that this test would correctly discriminate feline infectious peritonitis virus (FIPV) and feline enteric coronavirus (FECV). The study included 63 cats with signs consistent with FIP. FIP was confirmed in 38 cats. Twenty-five control cats were definitively diagnosed with a disease other than FIP. Effusion and/or serum/plasma samples were examined by real-time RT-PCR targeting the two FCoV spike gene fusion peptide mutations M1058 L and S1060A using an allelic discrimination approach. Sensitivity, specificity, negative and positive predictive values including 95% confidence intervals (95% CI) were calculated. FIPV was detected in the effusion of 25/59 cats, one of them being a control cat with chronic kidney disease. A mixed population of FIPV/FECV was detected in the effusion of 2/59 cats; all of them had FIP. RT-PCR was negative or the pathotype could not be determined in 34/59 effusion samples. In effusion, sensitivity was 68.6% (95% CI 50.7-83.2), specificity was 95.8% (95% CI 78.9-99.9). No serum/plasma samples were positive for FIPV. Although specificity of the test in effusions was high, one false positive result occurred. The use of serum/plasma cannot be recommended due to a low viral load in blood.
Peeters, Dominique; Peters, Iain R; Helps, Chris R; Dehard, Sandrine; Day, Michael J; Clercx, Cécile
2008-04-01
Various combinations of tests are used to confirm the diagnosis of canine sino-nasal aspergillosis (SNA) because false-positive and false-negative results can occur with each test. Therefore, the aim of this study was to evaluate whether detection of fungal DNA in blood and nasal tissue samples was of value in the clinical diagnosis of this disease. Four groups were included in the study (dogs with SNA, lymphoplasmacytic rhinitis or nasal neoplasia, and control animals). Real-time PCR assays detecting DNA from all Penicillium and Aspergillus species (PenAsp assay) or species-specific DNA from A. fumigatus, A. terreus, A. flavus and A. niger were applied to whole blood and nasal tissue samples. Results obtained by PCR were compared between the groups. Sensitivity, specificity, positive and negative predictive values (PPV and NPV) for fungal DNA detection were compared with those for alternative diagnostic procedures including histopathology, serology and fungal culture. Significantly more fungal DNA was detected by the PenAsp assay in tissue biopsies from dogs with SNA than in the three other groups. Sensitivity, specificity, PPV and NPV for this method were 1.00, 0.06, 0.32 and 1.00. A. fumigatus DNA was detected in seven tissue biopsies from dogs with SNA and in one biopsy from a dog with a nasal tumour. Sensitivity, specificity, PPV and NPV for this diagnostic test were 0.50, 0.97, 0.87 and 0.82. No significant difference was found between the groups with respect to the amount of DNA detected in blood by the PenAsp assay. Sensitivity, specificity, PPV and NPV for this method were 0.71, 0.24, 0.31 and 0.64. A. fumigatus DNA was detected in the blood of three dogs with SNA and sixteen dogs without SNA. Sensitivity, specificity, PPV and NPV for this diagnostic tool were 0.21, 0.45, 0.15 and 0.54. Detection of A. fumigatus DNA in nasal tissue had the highest specificity, PPV and NPV but sensitivity of this method was low. Detection of fungal DNA in whole blood was of no value in the diagnosis of SNA.
Correcting the MoCA for education: effect on sensitivity.
Gagnon, Genevieve; Hansen, Kevin T; Woolmore-Goodwin, Sarah; Gutmanis, Iris; Wells, Jennie; Borrie, Michael; Fogarty, Jennifer
2013-09-01
The goal of this study was to quantify the impact of the suggested education correction on the sensitivity and specificity of the Montreal Cognitive Assessment (MoCA). Twenty-five outpatients with dementia and 39 with amnestic mild cognitive impairment (aMCI) underwent a diagnostic evaluation, which included the MoCA. Thirty-seven healthy controls also completed the MoCA and psychiatric, medical, neurological, functional, and cognitive difficulties were ruled out. For the total MoCA score, unadjusted for education, a cut-off score of 26 yielded the best balance between sensitivity and specificity (80% and 89% respectively) in identifying cognitive impairment (people with either dementia or aMCI, versus controls). When applying the education correction, sensitivity decreased from 80% to 69% for a small specificity increase (89% to 92%). The cut-off score yielding the best balance between sensitivity and specificity for the education adjusted MoCA score fell to 25 (61% and 97%, respectively). Adjusting the MoCA total score for education had a detrimental effect on sensitivity with only a slight increase in specificity. Clinically, this loss in sensitivity can lead to an increased number of false negatives, as education level does not always correlate to premorbid intellectual function. Clinical judgment about premorbid status should guide interpretation. However, as this effect may be cohort specific, age and education corrected norms and cut-offs should be developed to help guide MoCA interpretation.
Eid, Issam; Miller, Frank R; Rowan, Stephanie; Otto, Randal A
2013-10-01
To determine the role and efficacy of intraoperative recurrent laryngeal nerve (RLN) stimulation in the prediction of early and permanent postoperative nerve function in thyroid and parathyroid surgery. A retrospective review of thyroid and parathyroid surgeries was performed with calculation of sensitivity and specificity of the response of intraoperative stimulation for different pathological groups. Normal electromyography (EMG) response with 0.5 mAmp stimulation was considered a positive stimulation response with postoperative function determined by laryngoscopy. No EMG response at >1-2 mAmps was considered a negative response. The rates of early and permanent paralysis, as well as sensitivity, specificity, and positive and negative predictive values for postoperative nerve function were calculated for separate pathological groups. The number of nerves at risk analyzed was 909. The overall early and permanent paralysis rates were 3.1% and 1.2%, respectively, with the highest rate being for Grave's disease cases. The overall sensitivity was 98.4%. The specificity was lower at 62.5% but acceptable in thyroid carcinoma and Grave's disease patients. The majority of nerves with a positive stimulation result and postoperative paralysis on laryngoscopy recovered function in 3 to 12 weeks, showing positive stimulation to be a good predictor of eventual recovery. Stimulation of the RLN during thyroid and parathyroid surgery is a useful tool in predicting postoperative RLN function. The sensitivity of stimulation is high, showing positive stimulation to be an excellent predictor of normal nerve function. Negative stimulation is more predictive of paralysis in cases of thyroid carcinoma and Grave's disease. 2b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Rapid detection of multidrug resistant Gram-negative bacilli by Cica-Beta-Test strips.
Lavigne, J-P; Pfeiffer, C; Vidal, L; Sotto, A
2011-02-01
This study aimed to evaluate the sensitivity and specificity of a new system (Cica-Beta-Test, Kanto Chemical, Japan) for rapid detection of AmpC-derepressed, extended-spectrum β-lactamases (ESβL) and metallo-β-lactamases (MβL). Two hundred Multi-Drug Resistant (MDR)-Gram-negative bacilli were studied: 170 Enterobacteriaceae and 30 Gram-negative non-fermentative bacteria. One hundred and eighteen strains produced an ESβL, seven MβL and 75 derepressed cephalosporinases. One drop of substrate was dispensed onto the filter pad of the Cica-Beta-Test strip. The bacterial colonies were spread on the filter pad of strip. The reading was performed after 2 to 15 min: turning chromogenic indicated the positive test. Three tests were used: Cica-Beta I for detection of MDR bacteria; Cica-Beta MβL for detection of MβL-producing bacteria and Cica-Beta CVA, which distinguish ESβL and AmpC-derepressed producers. Results were compared with molecular assays. Cica-Beta-Test I has detected 194 MDR (sensitivity 97%), Cica-Beta-Test MβL has shown the presence of six MβL tested (sensitivity 85.7%). Five strains were non-MβL false positive (specificity 97.3%). Cica-Beta-Test CVA allowed the differentiation of ESβL-producing strains (109/115) and AmpC-derepressed strains (56/67) (sensitivity 94.8%, specificity 83.8%). Because of their epidemic nature, the MDR strains are screened and require strict hygienic measures patients. The simultaneous use of three strips can quickly determine the presence of MDR including ESβL and MβL. Rapid screening of MDR avoids transmission and limits the use of broad-spectrum antibiotics. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
van Gend, Christine L; Haadsma, Maaike L; Sauer, Pieter J J; Schoeman, Cornelius J
2003-06-01
The WHO clinical case definition for pediatric HIV infection has been designed to be used in countries where diagnostic laboratory resources are limited. We evaluated the WHO case definition to determine whether it is a useful instrument to discriminate between HIV-positive and HIV-negative children. In addition, clinical features not included in this case definition were recorded. We recorded clinical data from 300 consecutively admitted children in a state hospital in Bloemfontein, South Africa, and tested these children for HIV infection. A total of 222 children were included in the study; 69 children (31.1 per cent) were HIV positive. The sensitivity of the WHO case definition in this study was 14.5 per cent, the specificity was 98.6 per cent. Apart from weight loss and generalized dermatitis, the signs of the WHO case definition were significantly more often seen in HIV-positive than in HIV-negative children. Of the clinical signs not included in the WHO case definition, marasmus and hepatosplenomegaly especially occurred more frequently in HIV-positive children. Based on these findings we composed a new case definition consisting of four signs: marasmus, hepatosplenomegaly, oropharyngeal candidiasis, and generalized lymphadenopathy. HIV infection is suspected in a child presenting with at least two of these four signs. The sensitivity of this case definition was 63.2 per cent, the specificity was 96.0 per cent. We conclude that in this study the WHO case definition was not a useful instrument to discriminate between HIV-positive and HIV-negative children, mainly because its sensitivity was strikingly low. The simplified case definition we propose, proved to be more sensitive than the WHO case definition (63.2 vs. 14.5 per cent), whilst its specificity remained high.
Evaluation of a Turbidimetric β-d-Glucan Test for Detection of Pneumocystis jirovecii Pneumonia.
Dichtl, Karl; Seybold, Ulrich; Wagener, Johannes
2018-07-01
Currently, diagnosis of Pneumocystis jirovecii pneumonia (PJP) relies on analysis of lower respiratory specimens, either by microscopy or quantitative real-time PCR (qPCR). Thus, bronchoscopy is required, which is associated with increased risk of respiratory failure. We assessed the value of noninvasive serologic β-d-glucan (BDG) testing for laboratory diagnosis of PJP using a newly available turbidimetric assay. We identified 73 cases of PJP with positive qPCR results from lower respiratory specimens for Pneumocystis and serology samples dating from 1 week before to 4 weeks after qPCR. In addition, 25 sera from controls with suspected PJP but specimens negative for Pneumocystis by qPCR were identified. Sera were tested with a turbidimetric BDG assay (Fujifilm Wako Chemicals Europe GmbH, Neuss, Germany), using an 11-pg/ml cutoff. Sensitivity and specificity were calculated based on qPCR test results as a reference. The turbidimetric BDG assay identified 63/73 patients with positive or slightly positive qPCR tests for an overall sensitivity of 86%; after exclusion of cases with only slightly positive qPCR results, sensitivity was 91%. No correlation between serum BDG levels and respiratory specimen DNA levels was found. Serologic BDG testing was negative in 25/25 controls with negative qPCR for a specificity of 100% using the predefined cutoff. In 22/25 samples (88%), no BDG was detected. Serologic BDG testing using the turbidimetric assay showed high sensitivity and specificity compared to qPCR of lower respiratory specimens for the diagnosis of PJP. Both turnover time and test performance will allow clinicians to delay or in some cases forego bronchoscopy. Copyright © 2018 American Society for Microbiology.
Abdel Rahman, Afaf S; Fahim, Nehal M A; El Sayed, Abeer A; El Hady, Soha A R; Ahmad, Yasser S
2005-01-01
Renal transplantation, in most countries, is based on human leukocyte antigen (HLA) matching of the donor kidney with the recipient. Traditional human leukocyte antigen matching is based on defining human leukocyte antigen specificities by antibodies utilizing cytotoxicity crossmatch techniques. Newer techniques have emerged, which challenge the accuracy of serological typing and crossmatching. We compared the results of the standard complement-dependent cytotoxicity crossmatch (CDCXM) with the anti-human globulin augmented cytotoxicity (AHG-CDC), and Flowcytometry crossmatch (FCXM) for the detection of anti-HLA antibodies in 150 pre-transplant patients. The development of post-transplantation sensitization was screened utilizing these three techniques within two weeks post-operative and correlated with rejection episodes. Comparison between the results of CDCXM and AHG-CDC in 150 recipients, revealed no significant correlation (P>0.05). When comparing these results with that of FCXM in 50 recipients a significant correlation was shown (P<0.05). Relative to CDCXM, the sensitivity of AHG-CDC was 100%, specificity 97.4%, positive predictive value 92.3%, and negative predictive value 100%. On the other hand, the sensitivity of FCXM was 100%, specificity 76.3%, positive predictive value 57.1%, and negative predictive value 100%. According to the results of CDCXM, AHG-CDC, and FCXM, no difference was detected between pre- and posttransplant anti-HLA sensitization within two weeks after the operation. Patients with negative cytotoxicity crossmatch (CDCXM and AHG-CDC) and positive FCXM may have an increased risk of early graft loss and may represent a relative contraindication to transplantation. Given the important theoretical advantages of FCXM over the CDC XM, further testing of the clinical relevance is warranted.
Amrhein, Timothy J; Mostertz, William; Matheus, Maria Gisele; Maass-Bolles, Genevieve; Sharma, Komal; Collins, Heather R; Kranz, Peter G
2017-02-01
Subdural hematomas (SDHs) comprise a significant percentage of missed intracranial hemorrhage on axial brain CT. SDH detection rates could be improved with the addition of reformatted images. Though performed at some centers, the potential additional diagnostic sensitivity of reformatted images has not yet been investigated. The purpose of our study is to determine if the addition of coronal and sagittal reformatted images to an axial brain CT increases the sensitivity and specificity for detection of acute traumatic SDH. We retrospectively reviewed consecutive brain CTs acquired for acute trauma that contained new SDHs. An equivalent number of normal brain CTs served as control. Paired sets of images were created for each case: (1) axial images only ("axial only") and (2) axial, coronal, sagittal images ("reformat added"). Three readers interpreted both the axial only and companion reformat added for each case, separated by 1 month. Reading times and SDH detection rates were compared. One hundred SDH and 100 negative examinations were collected. Sensitivity and specificity for the axial-only scans were 75.7 and 94.3 %, respectively, compared with 88.3 and 98.3 % for reformat added. There was a 24.3 % false negative (missed SDH) rate with axial-only scans versus 11.7 % with reformat added (p = <0.001). Median reader interpretation times were longer with the addition of reformatted images (125 versus 89 s), but this difference was not significant (p = 0.23). The addition of coronal and sagittal images in trauma brain CT resulted in improved sensitivity and specificity as well as a reduction in SDH false negatives by greater than 50 %. Reformatted images substantially reduce the number of missed SDHs compared with axial images alone.
[TSH anti-receptor antibodies in Graves' disease].
Sérgio, M R; Godinho, C; Guerra, L; Agapito, A; Fonseca, F; Costa, C
1996-01-01
The purpose of this study was to evaluate the sensitivity, specificity and predictive value of thyrotropin receptor antibody (TRAb) in the diagnosis of Graves disease. TRAb was tested by an isotopic receptor assay-TRAK Henning-in 80 newly diagnosed, untreated Graves disease patients (group I), 63 with other thyroid diseases (group II) and 60 controls (group III). In group I, 11 patients were TRAb negative and 7 were considered in the gray area (TRAb between 9 and 14 U/L). In group II, only 2 patients had TRAb 9 U/l and all controls were TRAb negative. For statistical analysis patients with TRAb in gray area were excluded. Sensitivity and specificity for this assay were 84.5 and 100% respectively. Predictive value of 100% affords certainty that a hyperthyroid patient with a positive TRAb has Graves disease, not sequining a scintigram.
Ivo-Dos-Santos, J; Mello, D L; Couto-Fernandez, J C; Passos, R M; Dias-Carneiro, L A; Castilho, E A; Galvão-Castro, B
1990-01-01
Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.
Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo
2014-07-01
The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.
Barletta, Francesca; Vandelannoote, Koen; Collantes, Jimena; Evans, Carlton A; Arévalo, Jorge; Rigouts, Leen
2014-10-01
Real-time polymerase chain reaction (qPCR) was optimized for detecting Mycobacterium tuberculosis in sputum. Sputum was collected from patients (N = 112) with suspected pulmonary tuberculosis, tested by smear microscopy, decontaminated, and split into equal aliquots that were cultured in Löwenstein-Jensen medium and tested by qPCR for the small mobile genetic element IS6110. The human ERV3 sequence was used as an internal control. 3 of 112 (3%) qPCR failed. For the remaining 109 samples, qPCR diagnosed tuberculosis in 79 of 84 patients with culture-proven tuberculosis, and sensitivity was greater than microscopy (94% versus 76%, respectively, P < 0.05). The qPCR sensitivity was similar (P = 0.9) for smear-positive (94%, 60 of 64) and smear-negative (95%, 19 of 20) samples. The qPCR was negative for 24 of 25 of the sputa with negative microscopy and culture (diagnostic specificity 96%). The qPCR had 99.5% sensitivity and specificity for 211 quality control samples including 84 non-tuberculosis mycobacteria. The qPCR cost ∼5US$ per sample and provided same-day results compared with 2-6 weeks for culture. © The American Society of Tropical Medicine and Hygiene.
Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D
2006-02-01
Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.
Evaluation of ID-PaGIA syphilis antibody test.
Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi
2009-01-01
Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan
2017-01-01
Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268
Warkentin, Theodore E; Sheppard, Jo-Ann I; Linkins, Lori-Ann; Arnold, Donald M; Nazy, Ishac
2017-05-01
Heparin-induced thrombocytopenia (HIT) is a prothrombotic drug reaction caused by platelet-activating anti-PF4/heparin antibodies. Given time-sensitive treatment considerations, a rapid and accurate laboratory test for HIT antibodies is needed. To determine operating characteristics for the HemosIL ® HIT-Ab (PF4/H) , a rapid, on-demand, fully-automated, latex immunoturbidimetric assay (LIA), for diagnosis of HIT. We evaluated LIA sensitivity, specificity, negative (NPV) and positive predictive value (PPV), negative (LR-) and positive likelihood ratio (LR+), using citrated-plasma from 429 patients (prospective cohort study of 4Ts scoring; HIT, n=31), and from consecutive HIT patients (n=125), using reference standard serotonin-release assay (SRA). Comparators included two PF4-dependent enzyme-immunoassays (EIAs). We used stratum-specific likelihood ratios (SSLRs) to determine how differing magnitudes of LIA-positivity influenced post-test probability of HIT. LIA operating characteristics were: sensitivity=97.4% (152/156); specificity=94.0% (374/398); PPV=55.6% (30/54); and NPV=99.7% (374/375). At manufacturers' cutoffs, LIA specificity and PPV were superior to the EIAs. Although a negative LIA pointed strongly against HIT (LR-, 0.034), the post-test probability was ~2% with high 4Ts score. The LIA's LR+ was high (16.0), with SSLRs rising substantially with greater LIA-positivity: 5.7 (1.0-4.9U/mL), 31 (5.0-15.9U/mL), and 128 (≥16U/mL). A LIA-positive result (at 1.0 cutoff) indicated at least 24% HIT probability (low 4Ts score), rising to 90% with high 4Ts score. Although approximately 1 in 40 SRA-positive patients tested LIA-negative, the LIA's high NPV and PPV indicate that this rapid assay is useful for the diagnostic evaluation of HIT, including in low pre-test situations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S
2017-05-01
The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Nishimura, Katsuji; Yokoyama, Kanako; Yamauchi, Noriko; Koizumi, Masako; Harasawa, Nozomi; Yasuda, Taeko; Mimura, Chizuru; Igita, Hazuki; Suzuki, Eriko; Uchiide, Yoko; Seino, Yusuke; Nomura, Minoru; Yamazaki, Kenji; Ishigooka, Jun
2016-01-01
To compare the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) for detecting post-cardiac surgery delirium. These tools have not been tested in a specialized cardio-surgical ICU. Sensitivities and specificities of each tool were assessed in a cardio-surgical ICU in Japan by two trained nurses independently. Results were compared with delirium diagnosed by psychiatrists using the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision. There were 110 daily, paired assessments in 31 patients. The CAM-ICU showed 38% sensitivity and 100% specificity for both nurses. All 20 false-negative cases resulted from high scores in the auditory attention screening in CAM-ICU. The ICDSC showed 97% and 94% sensitivity, and 97% and 91% specificity for the two nurses (cutoff ≥4). In a Japanese cardio-surgical ICU, the ICDSC had a higher sensitivity than the CAM-ICU. Copyright © 2016 Elsevier Inc. All rights reserved.
van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P
2013-09-01
In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects. Copyright © 2013 Elsevier B.V. All rights reserved.
Diagnosis of subclinical mastitis in Santa Inês and Morada Nova sheep in southeastern Brazil.
Zafalon, Luiz Francisco; Santana, Raul Costa Mascarenhas; Pilon, Lucas Eduardo; Júnior, Guilherme Aparecido Fim
2016-06-01
The objective of this study was to evaluate different screening limits for the California mastitis test (CMT) and the somatic cell count (SCC) in previous diagnoses of subclinical mastitis in Santa Inês and Morada Nova ewes, which were reared under the same management conditions. Additionally, cutoff points were defined for SCC in accordance with the sensitivity and specificity of the test. A total of 907 mammary halves were subjected to CMT and SCC. The disease was confirmed by means of microbiological identification. Coagulase-negative staphylococci (CNS) were the microorganisms with highest occurrence. The CMT score of 1+ provided adequate sensitivity and specificity at all periods of lactation investigated. This score showed good agreement with SCC, >400,000 cells mL(-1). Higher cell counts favored higher diagnostic specificity. They can be used when producers have financial difficulties relating to treatment or culling of sheep with subclinical mastitis. However, producers should be warned about the risk of false-negative results in the flock.
The efficacy of sentinel lymph node mapping with indocyanine green in cervical cancer.
Kim, Ju-Hyun; Kim, Dae-Yeon; Suh, Dae-Shik; Kim, Jong-Hyeok; Kim, Yong-Man; Kim, Young-Tak; Nam, Joo-Hyun
2018-03-09
Lymph node metastasis is a significant predictive factor for disease recurrence and survival in cervical cancer patients. Given the importance of lymph node metastasis, it is imperative that patients harboring metastasis are identified and can undergo appropriate treatment. Sentinel lymph node (SLN) mapping has drawn attention as a lymph node mapping technique. We evaluated the feasibility and efficacy of (SLN) mapping using indocyanine green (ICG) in cervical cancer. We performed a single-center, retrospective study of 103 surgically treated cervical cancer patients who underwent SLN mapping. After using ICG to detect SLN during surgery, we removed the SLNs followed by laparoscopic or robotic-assisted radical surgery and bilateral pelvic lymphadenectomy. Stage IB1 was the most common (61.17%). At least one SLN was detected in all cases. Eighty-eight patients (85.44%) had bilateral pelvic SLNs. The mean number of SLN per patient was 2.34. The side-specific sensitivity was 71.43%, the specificity was 100%, the negative predictive value (NPV) was 93.98%, and the false negative rate (FNR) was 28.57%. In cases of tumors smaller than 2 cm with negative lymph node metastasis on imaging, the study revealed a side-specific sensitivity of 100%, a specificity of 100%, a NPV of 100%, and a FNR of 0%. Large tumor size (≥ 4 cm), a previous history of a loop electrosurgical excision procedure (LEEP), depth of invasion (≥ 50%), the microscopic parametrial (PM) invasion, and vaginal extension were significantly associated with the false-negative detection of SLN. Moreover, the microscopic PM invasion was the only risk factor of the false-negative detection of SLN in multivariate analysis. SLN mapping with ICG in cervical cancer is feasible and has high detection rate. The sensitivity of 100% was high enough to perform SLN biopsy alone in an early stage in which the tumor is less than 2 cm, with no lymphadenopathy on image examination. However, for large or invasive tumors, we would have to be cautious about performing SLN biopsy alone. Retrospectively registered 2017-0600.
Accuracy of ultrasound for the prediction of placenta accreta.
Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M
2014-08-01
Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.
Li, James J
2018-03-20
Atypical reward processing, including abnormal reward responsivity and sensitivity to punishment, has long been implicated in the etiology of ADHD. However, little is known about how these facets of behavior interact with positive (e.g., warmth, praise) and negative (e.g., hostility, harsh discipline) parenting behavior in the early expression of ADHD symptoms in young children. Understanding the interplay between children's reward processing and parenting may be crucial for identifying specific treatment targets in psychosocial interventions for ADHD, especially given that not all children benefit from contingency-based treatments (e.g., parent management training). The study consisted of a sample of kindergarten children (N = 201, 55% male) and their parents, who completed questionnaires about their parenting practices, their child's behaviors and participated in an observed parent-child play task in the laboratory. Children's reward responsivity and sensitivity to punishment were positively associated with child ADHD symptoms. However, children with high reward responsivity had more symptoms of ADHD but only under conditions of low negative parenting (self-reported and observed) and high self-reported positive parenting, compared to children with low reward responsivity. Children with high sensitivity to punishment had more ADHD symptoms relative to children with low sensitivity to punishment, but only under conditions in which observed praise was infrequent. Results provide evidence that individual differences in sensitivity to reward/punishment may be an important of marker of risk for ADHD, but also highlights how children's responses to positive and negative parenting behavior may vary by children's sensitivities. Clinical and treatment implications are discussed.
Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita
2017-05-01
To examined the diagnostic value of dilatation and curettage (D and C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D and C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to AUB and who had undergone hysterectomy were investigated. The patients' characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D and C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D and C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps.
Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita
2017-01-01
Objectives: To examined the diagnostic value of dilatation and curettage (D&C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D&C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to AUB and who had undergone hysterectomy were investigated. The patients’ characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D&C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D&C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps. PMID:28439599
Higdon, Melissa M; Le, Tham; O'Brien, Katherine L; Murdoch, David R; Prosperi, Christine; Baggett, Henry C; Brooks, W Abdullah; Feikin, Daniel R; Hammitt, Laura L; Howie, Stephen R C; Kotloff, Karen L; Levine, Orin S; Scott, J Anthony G; Thea, Donald M; Awori, Juliet O; Baillie, Vicky L; Cascio, Stephanie; Chuananon, Somchai; DeLuca, Andrea N; Driscoll, Amanda J; Ebruke, Bernard E; Endtz, Hubert P; Kaewpan, Anek; Kahn, Geoff; Karani, Angela; Karron, Ruth A; Moore, David P; Park, Daniel E; Rahman, Mohammed Ziaur; Salaudeen, Rasheed; Seidenberg, Phil; Somwe, Somwe Wa; Sylla, Mamadou; Tapia, Milagritos D; Zeger, Scott L; Deloria Knoll, Maria; Madhi, Shabir A
2017-06-15
Lack of a gold standard for identifying bacterial and viral etiologies of pneumonia has limited evaluation of C-reactive protein (CRP) for identifying bacterial pneumonia. We evaluated the sensitivity and specificity of CRP for identifying bacterial vs respiratory syncytial virus (RSV) pneumonia in the Pneumonia Etiology Research for Child Health (PERCH) multicenter case-control study. We measured serum CRP levels in cases with World Health Organization-defined severe or very severe pneumonia and a subset of community controls. We evaluated the sensitivity and specificity of elevated CRP for "confirmed" bacterial pneumonia (positive blood culture or positive lung aspirate or pleural fluid culture or polymerase chain reaction [PCR]) compared to "RSV pneumonia" (nasopharyngeal/oropharyngeal or induced sputum PCR-positive without confirmed/suspected bacterial pneumonia). Receiver operating characteristic (ROC) curves were constructed to assess the performance of elevated CRP in distinguishing these cases. Among 601 human immunodeficiency virus (HIV)-negative tested controls, 3% had CRP ≥40 mg/L. Among 119 HIV-negative cases with confirmed bacterial pneumonia, 77% had CRP ≥40 mg/L compared with 17% of 556 RSV pneumonia cases. The ROC analysis produced an area under the curve of 0.87, indicating very good discrimination; a cut-point of 37.1 mg/L best discriminated confirmed bacterial pneumonia (sensitivity 77%) from RSV pneumonia (specificity 82%). CRP ≥100 mg/L substantially improved specificity over CRP ≥40 mg/L, though at a loss to sensitivity. Elevated CRP was positively associated with confirmed bacterial pneumonia and negatively associated with RSV pneumonia in PERCH. CRP may be useful for distinguishing bacterial from RSV-associated pneumonia, although its role in discriminating against other respiratory viral-associated pneumonia needs further study. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Mandhaniya, Sushil; Iqbal, Sobuhi; Sharawat, Surender Kumar; Xess, Immaculata; Bakhshi, Sameer
2012-07-01
Invasive fungal infections (IFI) lead to morbidity and mortality in neutropenic patients and in allogenic stem cell transplantation. Serum-based fungal detection assays have limitation of specificity or sensitivity. Studies on fungal DNA detection using real-time PCR in childhood leukaemia are lacking. The aim of this study was to develop sensitive and specific diagnostic tools for IFI in paediatric acute leukaemia patients using real-time PCR. Of 100 randomised paediatric acute leukaemia patients receiving antifungal prophylaxis with voriconazole/amphotericin B, single peripheral whole blood sample in EDTA was used for Pan-AC real-time PCR assay (detects nine Candida and six Aspergillus species) in patients who failed prophylaxis due to proven, probable, possible or suspected fungal infections. PCR results were retrospectively correlated with clinical profile. Real-time PCR test was positive in 18/29 (62%) patients who failed prophylaxis. The only patient with proven IFI (mucormycosis), real-time PCR assay was negative. Real-time PCR was positive in 2/4 (50%) patients with possible and 16/24 (66.6%) suspected IFI and 5/10 (50%) patients with pneumonia. By applying method A/B, sensitivity and positive predictive value could not be commented due to unproven Aspergillus or Candida infections; specificity and negative predictive values (NPV) were 41% and 100% respectively; by method C (included episodes of possible IFI as true positive), sensitivity, specificity, PPV and NPV were 50%, 36%, 11% and 81% respectively. In those with suspected IFI, 8/24 (33.3%) were PCR negative and unnecessarily received empirical antifungal therapy (EAFT). Real-time PCR is a practical, rapid, non-invasive screening test for excluding IFI in paediatric leukaemia. The high NPV makes real-time PCR a promising tool to use this prior to initiating EAFT in antibiotic-resistant febrile neutropenic patients; this would avoid toxicity, cost and hospitalisation for EAFT (ClinicalTrials.gov identifier:NCT00624143). © 2011 Blackwell Verlag GmbH.
Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R
2017-09-01
Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.
A controlled trial of automated classification of negation from clinical notes
Elkin, Peter L; Brown, Steven H; Bauer, Brent A; Husser, Casey S; Carruth, William; Bergstrom, Larry R; Wahner-Roedler, Dietlind L
2005-01-01
Background Identification of negation in electronic health records is essential if we are to understand the computable meaning of the records: Our objective is to compare the accuracy of an automated mechanism for assignment of Negation to clinical concepts within a compositional expression with Human Assigned Negation. Also to perform a failure analysis to identify the causes of poorly identified negation (i.e. Missed Conceptual Representation, Inaccurate Conceptual Representation, Missed Negation, Inaccurate identification of Negation). Methods 41 Clinical Documents (Medical Evaluations; sometimes outside of Mayo these are referred to as History and Physical Examinations) were parsed using the Mayo Vocabulary Server Parsing Engine. SNOMED-CT™ was used to provide concept coverage for the clinical concepts in the record. These records resulted in identification of Concepts and textual clues to Negation. These records were reviewed by an independent medical terminologist, and the results were tallied in a spreadsheet. Where questions on the review arose Internal Medicine Faculty were employed to make a final determination. Results SNOMED-CT was used to provide concept coverage of the 14,792 Concepts in 41 Health Records from John's Hopkins University. Of these, 1,823 Concepts were identified as negative by Human review. The sensitivity (Recall) of the assignment of negation was 97.2% (p < 0.001, Pearson Chi-Square test; when compared to a coin flip). The specificity of assignment of negation was 98.8%. The positive likelihood ratio of the negation was 81. The positive predictive value (Precision) was 91.2% Conclusion Automated assignment of negation to concepts identified in health records based on review of the text is feasible and practical. Lexical assignment of negation is a good test of true Negativity as judged by the high sensitivity, specificity and positive likelihood ratio of the test. SNOMED-CT had overall coverage of 88.7% of the concepts being negated. PMID:15876352
NASA Astrophysics Data System (ADS)
Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong
2013-11-01
Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.
Hammerschlag, M R; Roblin, P M; Gelling, M; Tsumura, N; Jule, J E; Kutlin, A
1997-03-01
Chlamydia trachomatis is the most common identifiable infectious cause of neonatal conjunctivitis. Nonculture tests including enzyme immunoassays and direct fluorescent antibody tests have been shown to perform well for the diagnosis of chlamydial conjunctivitis with sensitivities and specificities > or = 90%. However, the performance with respiratory specimens has been less than satisfactory. We compared a new, commercially available polymerase chain reaction (PCR) assay, Roche AMPLICOR (Roche Diagnostic Systems, Branchburg, NJ) with culture for the detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis. We also evaluated AMPLICOR for the detection of C. trachomatis in the urine of mothers of positive infants. Ocular and nasopharyngeal specimens from 75 infants with conjunctivitis were obtained for culture and PCR. AMPLICOR was equivalent to culture for eye specimens and more sensitive than culture for nasopharyngeal specimens. The sensitivity, specificity and positive and negative predictive values of PCR compared with culture for conjunctival specimens were 92.3, 100, 100 and 98.4%, respectively. The sensitivity, specificity and positive and negative predictive values for nasopharyngeal specimens were 100, 97.2, 60 and 100%, respectively. We also detected C. trachomatis by PCR in the urine of 12 mothers of culture positive infants. PCR performed comparably to culture for detection of C. trachomatis in conjunctival and nasopharyngeal specimens from infants with conjunctivitis.
Somily, Ali M; Barry, Mazin A; Habib, Hanan A; Alotaibi, Fawzia E; Al-Zamil, Fahad A; Khan, Mohammed A; Sarwar, Mohammed S; Bakhash, Nawab D; Alrabiaah, Abdulkarim A; Shakoor, Zahid A; Senok, Abiola C
2016-12-01
To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods: This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results: Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion: The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens.
Somily, Ali M.; Barry, Mazin A.; Habib, Hanan A.; Alotaibi, Fawzia E.; Al-Zamil, Fahad A.; Khan, Mohammed A.; Sarwar, Mohammed S.; Bakhash, Nawab D.; Alrabiaah, Abdulkarim A.; Shakoor, Zahid A.; Senok, Abiola C.
2016-01-01
Objectives To assess the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), against smear microscopy and culture method for diagnosis of MTB infection. Methods This is a retrospective analysis of 103 respiratory and 137 non-respiratory patient specimens suspected of tuberculosis at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia performed between April 2014 and March 2015. Each sample underwent smear microscopy, mycobacterial culture, and GeneXpert MTB/RIF test. Results Fifteen out of 103 respiratory samples were smear and culture positive, whereas 9 out of 137 non-respiratory samples were smear positive. Out of 9 smear positive specimens, 8 were also culture positive. All 15 culture positive respiratory samples were detected by Xpert MTB/RIF (sensitivity and positive predictive value [PPV]=100%). Similarly, all 8 culture positive non-respiratory specimens were identified by Xpert MTB/RIF (sensitivity 100%; PPV 88.8%). The Xpert MTB/RIF detected only one false positive result in 88 smear negative respiratory specimens (specificity 98.9%; negative predictive value [NPV]= 100%). All 125 smear negative non-respiratory specimens tested negative by culture and Xpert MTB/RIF (sensitivity, specificity, PPV, NPV= 100%). Conclusion The performance of Xpert MTB/RIF was comparable to the gold standard culture method for identification of MTB in both respiratory and non-respiratory clinical specimens. PMID:27874159
Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?
Schaarschmidt, Benedikt Michael; Grueneisen, Johannes; Stebner, Vanessa; Klode, Joachim; Stoffels, Ingo; Umutlu, Lale; Schadendorf, Dirk; Heusch, Philipp; Antoch, Gerald; Pöppel, Thorsten Dirk
2018-06-06
To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.
Swan-neck sign of the big toe - association with hypocalcaemia.
Agarwal, Kishore S; Baijal, Noopur; Tiwari, Lokesh; Verma, Neeraj; Sahni, Mohit; Puliyel, Jacob M
2007-10-01
The sensitivity and specificity of a new clinical sign of hypocalcaemia were evaluated. The Swan-neck sign, wherein infants with symptomatic hypocalcaemia keep their big toe hyperextended at the metatarsophalangeal joint and flexed at the interphalangeal joint, was looked for in 25 infants presenting with non-febrile seizures, alongside their serum calcium levels. The study showed that the sign had a sensitivity of 63.6% and specificity of 66.6%. (Predictive values of positive and negative tests were 93.3% and 20%, respectively.) This is compared with the standard Trousseau and Chvostek signs.
Accuracy of ultrasound versus computed tomography urogram in detecting urinary tract calculi.
Salinawati, B; Hing, E Y; Fam, X I; Zulfiqar, M A
2015-08-01
To determine the (i) sensitivity and specificity of ultrasound (USG) in the detection of urinary tract calculi, (ii) size of renal calculi detected on USG, and (iii) size of renal calculi not seen on USG but detected on computed tomography urogram (CTU). A total of 201 patients' USG and CTU were compared retrospectively for the presence of calculi. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of USG were calculated with CTU as the gold standard. From the 201 sets of data collected, 59 calculi were detected on both USG and CTU. The sensitivity and specificity of renal calculi detection on USG were 53% and 85% respectively. The mean size of the renal calculus detected on USG was 7.6 mm ± 4.1 mm and the mean size of the renal calculus not visualised on USG but detected on CTU was 4 mm ± 2.4 mm. The sensitivity and specificity of ureteric calculi detection on USG were 12% and 97% respectively. The sensitivity and specificity of urinary bladder calculi detection on USG were 20% and 100% respectively. This study showed that the accuracy of US in detecting renal, ureteric and urinary bladder calculi were 67%, 80% and 98% respectively.
Getnet, Gebeyaw; Getie, Sisay; Srivastava, Mitaly; Birhan, Wubet; Fola, Abebe A; Noedl, Harald
2015-11-01
To assess the performance of RDTs against nested polymerase chain reaction (nPCR) for the diagnosis of malaria in public health facilities in north-western Ethiopia. Cross-sectional study at public health facilities in North Gondar, Ethiopia, of 359 febrile patients with signs and symptoms consistent with malaria. Finger prick blood samples were collected for testing in a P. falciparum/pan-malaria RDTs and for molecular analysis. Sensitivity, specificity and predictive values were determined for the RDTs using nPCR as reference diagnostic method. Kappa value was determined to demonstrate the consistency of the results between the diagnostic tools. By RDTs, 22.28% (80/359) of patients tested positive for malaria, and by nPCR, 27.02% (97/359) did. In nPCR, 1.67% (6/359) and 0.28% (1/359) samples were positive for P. ovale and P. malariae, which had almost all tested negative in the RDTs. The sensitivity, specificity, positive and negative predictive values of RDTs for the diagnosis of malaria were 62.9%, 92.7%, 76.3% and 87.1%, respectively, with 0.589 measurement agreement between RDTs and nPCR. The sensitivity and specificity of RDTs for P. falciparum identification only were 70.8% and 95.2%, and 65.2% and 93.1% for P. vivax. Although RDTs are commonly used at health posts in resource-limited environments, their sensitivity and specificity for the detection and species identification of Plasmodium parasites were poor compared to nPCR, suggesting caution in interpreting RDTs results. Particularly, in the light of expanded efforts to eliminate malaria in the country, more sensitive diagnostic procedures will be needed. © 2015 John Wiley & Sons Ltd.
Serum Protein Electrophoresis in the Evaluation of Lytic Bone Lesions
Nystrom, Lukas M.; Buckwalter, Joseph A.; Syrbu, Sergei; Miller, Benjamin J.
2013-01-01
Serum protein electrophoresis (SPEP) is often obtained at the initial evaluation of a radiolucent bone lesion of unknown etiology. The results are considered convincing evidence of the presence or absence of a plasma cell neoplasm. The sensitivity and specificity of the SPEP have not been reported in this clinical scenario. Our purpose is to assess the diagnostic value of the SPEP in the initial work-up of the radiolucent bone lesion. We identified 182 patients undergoing evaluation of a radiolucent bone lesion that included tissue biopsy and an SPEP value. We then calculated the sen-sitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of SPEP as a diagnostic test for a plasma cell neo-plasm in this clinical scenario. Forty-six of 182 (25.3%) patients in our series were diagnosed with a plasma cell neo-plasm by histopathologic analysis. The sensitivity of SPEP was 71% and the specificity was 83%. PPV was 47% and NPV was 94%. When analyzing only those presenting with multiple lesions, the percentage of patients diag-nosed with multiple myeloma increased to 44.7% (34 of 76 patients). The SPEP, however, did not have a substantially increased diagnostic accuracy with sensitivity of 71%, specificity 79%, PPV 40% and NPV 93%. SPEP lacks sensitivity and positive predictive value to provide a definitive diagnosis of myeloma in radiolucent bone lesions, but has a high negative predictive value which may make it useful in ruling out the disease. We recommend that this test either be performed in conjunction with urine electrophoresis, immunofixation electro-phoresis and free light chain assay, or after biopsy confirming the diagnosis of myeloma. PMID:24027470
Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B
2013-06-01
Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.
Kim, Daniel J; Francispragasam, Mario; Docherty, Gavin; Silver, Byron; Prager, Ross; Lee, Donna; Maberley, David
2018-05-18
Previous studies of point of care ultrasound (POCUS) have reported high sensitivities and specificities for retinal detachment (RD). Our primary objective was to assess the test characteristics of POCUS performed by a large heterogeneous group of emergency physicians (EPs) for the diagnosis of RD. This was a prospective diagnostic test assessment of POCUS performed by EPs with varying ultrasound experience on a convenience sample of emergency department (ED) patients presenting with flashes or floaters in one or both eyes. After standard ED assessment, EPs performed an ocular POCUS scan targeted to detect the presence or absence of RD. After completing their ED visit, all patients were assessed by a retina specialist who was blinded to the results of the POCUS scan. We calculated sensitivity and specificity with associated exact binomial confidence intervals (CI) using the retina specialist's final diagnosis as the reference standard. A total of 30 EPs enrolled 115 patients, with median age of 60 years and 64% female. The retina specialist diagnosed RD in 16 (14%) cases. The sensitivity and specificity of POCUS for detecting RD was 75% (95% CI 48%-93%) and 94% (95% CI 87%-98%), respectively. The positive likelihood ratio was 12.4 (95% CI 5.4-28.3), and negative likelihood ratio was 0.27 (95% CI 0.11-0.62). A large heterogeneous group of EPs can perform POCUS with high specificity but only intermediate sensitivity for RD. A negative POCUS scan in the ED performed by a heterogeneous group of providers after a one-hour POCUS didactic is not sufficiently sensitive to rule out RD in a patient with new onset flashes or floaters. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Simental-Mendía, Luis E; Simental-Mendía, Esteban; Rodríguez-Hernández, Heriberto; Rodríguez-Morán, Martha; Guerrero-Romero, Fernando
2016-01-01
Introduction and aim. Given that early identification of non-alcoholic fatty liver disease (NAFLD) is an important issue for primary prevention of hepatic disease, the objectives of this study were to evaluate the efficacy of the product of triglyceride and glucose levels (TyG) for screening simple steatosis and non-alcoholic steatohepatitis (NASH) in asymptomatic women, and to compare its efficacy vs. other biomarkers for recognizing NAFLD. Asymptomatic women aged 20 to 65 years were enrolled into a cross-sectional study. The optimal values of TyG, for screening simple steatosis and NASH were established on a Receiver Operating Characteristic scatter plot; the sensitivity, specificity, and likelihood ratios of TyG index were estimated versus liver biopsy. According sensitivity and specificity, the efficacy of TyG was compared versus the well-known clinical biomarkers for recognizing NAFLD. A total of 50 asymptomatic women were enrolled. The best cutoff point of TyG for screening simple steatosis was 4.58 (sensitivity 0.94, specificity 0.69); in addition, the best cutoff point of TyG index for screening NASH was 4.59 (sensitivity 0.87, specificity 0.69). The positive and negative likelihood ratios were 3.03 and 0.08 for simple steatosis, and 2.80 and 0.18 for NASH. As compared versus SteatoTest, NashTest, Fatty liver index, and Algorithm, the TyG showed to be the best test for screening. TyG has high sensitivity and low negative likelihood ratio; as compared with other clinical biomarkers, the TyG showed to be the best test for screening simple steatosis and NASH.
San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J
2005-03-01
Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows: 73% sensitivity, 98% specificity, 90% positive predictive value, and 93% negative predictive value. Blood culture is an accurate test for the early diagnosis of PSM in febrile patients after cardiac surgery, particularly in institutions where S. aureus is prevalent in this context. A negative blood culture practically excludes PSM and, during the period of maximum risk for PSM, the presence of S. aureus bacteremia should compel early surgical management.
Lai, Y M; Feng, Q; Sun, Y; Wang, P; Shi, Y F; Zhao, M; Wu, Q; Li, X H
2016-09-08
To evaluate the expression of epidermal growth factor receptor (EGFR) mutation specific antibodies in invasive lung adenocarcinomas, and their sensitivity, specificity, as well as relationship to histological subtypes. Immunostaining with EGFR mutation-specific antibodies, del E746-A750 in exon 19 and L858R in exon 21, was performed in tissue microarrays of 884 cases of resection specimens to study the relationship between the immunophenotypes and morphologic subtypes. The sensitivity and specificity of the stains were compared with gene mutations detected by amplified refractory mutation system-polymerase chain reaction (ARMS-PCR). Of the 884 cases, the expression of del E746-A750 in exon 19 was 3+ , 2+ , 1+ and 0 in 7 cases (0.79%), 38 cases (4.30%), 129 cases (14.59%) and 710 cases (80.32%), respectively. For L858R in exon 21, 3+ , 2+ , 1+ and 0 staining were seen in 82 cases (9.28%), 93 cases (10.52%), 82 cases (9.28%) and 627 cases (70.93%), respectively. For both antibodies, positive expression (1+ or more) was mainly observed in lepidic, acinar and papillary predominant subtypes, and rarely seen in solid subtype or invasive mucinous adenocarcinoma (P=0.014 and 0.016). If 1+ to 3+ expression was set as positive, the specificity of exon 19/exon 21 reached 98.59%/92.98%, while the sensitivity was relatively lower (62.86%/88.89%). If 2+ to 3+ expression was read as positive, the specificity and sensitivity were 99.30%/97.37% and 25.71%/74.60% for exon 19/exon 21. If only 3+ expression was considered positive, the specificity was 100.0% for both antibodies, with a low sensitivity (8.57% for exon 19 and 34.92% for exon 21). Of the 18 cases with E746-A750 del in exon 19 based on molecular detection, the sensitivity of immunohistochemistry for exon 19 was 88.89% if a positive cutoff value ≥1+ was used; in contrast, of the 8 cases harboring other deletions in exon 19, only two cases were positive as 1+ . Both the EGFR mutation specific antibodies del E746-A750 in exon 19 and L858R in exon 21 demonstrate high specificity and relatively low sensitivity, and are mostly expressed in lepidic, acinar and papillary predominant subtypes, but rarely in solid subtype or invasive mucinous adenocarcinoma. For cases with 3+ expression, a mutational statue for EGFR is likely. For the 2+ positive cases, the accuracy to predict mutation almost reaches 90%, but molecular detection for confirmation is desirable. For the 1+ and negative cases, DNA-based test is essential to avoid false negativity.
Novel autoantibody markers for early and seronegative rheumatoid arthritis.
Somers, Klaartje; Geusens, Piet; Elewaut, Dirk; De Keyser, Filip; Rummens, Jean-Luc; Coenen, Marieke; Blom, Marlies; Stinissen, Piet; Somers, Veerle
2011-02-01
Approximately one-third of rheumatoid arthritis (RA) patients are seronegative for the 2 serological RA markers, rheumatoid factor (RF) and antibodies against cyclic citrullinated peptides (ACCP). Moreover, the sensitivities of both markers are lower in the diagnostically important early disease phase. The aim of this study was to identify additional autoantibody markers for early RA and for RF-negative, ACCP-negative (seronegative) RA. We screened an RA synovium cDNA phage display library with autoantibodies in plasma from 10 early (symptoms of maximum 1 year) and 10 seronegative (RF-negative, ACCP-negative) RA patients with validation in 72 additional RA patients and 121 controls (38 healthy controls, 43 patients with other inflammatory rheumatic diseases, 20 osteoarthritis patients and 20 subjects with mechanical joint complaints). Fourteen novel autoantibodies were identified that showed a 54% sensitivity and 90% specificity for RA. For 11 of these autoantibodies, an exclusive presence was demonstrated in RA patients (100% specificity, 37% sensitivity) as compared to controls. All early RA patients were positive for at least one of the identified autoantibodies and antibody-positivity was associated with a shorter disease duration (P = 0.0087). 52% of RA patients who initially tested negative for RF and ACCP, tested positive for at least one of the 14 novel autoantibodies, resulting in a 19% increase in sensitivity compared to current serological testing. Moreover, 5 identified autoantibodies were detected more frequently in seronegative RA patients, indicating that these autoantibodies constitute novel candidate markers for this RA subtype. We demonstrated that the targets of 3 of these 5 autoantibodies had an increased expression in RA synovial tissue compared to control synovial tissue, pointing towards a biological rationale for these auto antibody targets in RA. In conclusion, we identified novel candidate autoantibody markers for RA that can be detected in early and seronegative RA patients indicating the potential added value for RA diagnostics. Copyright © 2010 Elsevier Ltd. All rights reserved.
Streamlining the Evaluation of Low Back Pain in Children
Auerbach, Joshua D.; Ahn, Jaimo; Zgonis, Miltiadis H.; Reddy, Sudheer C.; Ecker, Malcolm L.
2008-01-01
The workup of low back pain in children often results in overimaging so as not to miss organic back pain. The primary goal of this study was to identify which combination of imaging modalities provides the most sensitive and specific screening protocol for children with low back pain. Medical records from 100 consecutive patients between 2 and 18 years of age presenting with low back pain, without night pain or constitutional symptoms, were evaluated. A hyperextension test combined with a radiograph showed a negative predictive value of 0.81 and sensitivity of 0.90. The addition of a bone scan was highly effective in achieving good negative predictive value and sensitivity. Bone scans had perfect negative predictive value and sensitivity when symptom duration was less than 6 weeks. We identified a set of factors that is highly predictive for distinguishing organic back pain from mechanical back pain. Painless hyperextension combined with negative anteroposterior, lateral, and oblique lumbar radiographs and magnetic resonance images predicts mechanical back pain. For patients with nonneurologic back pain of less than 6 weeks duration, bone scan is the most useful screening test because it is accurate, accessible, inexpensive, and unlikely to require sedation. Level of Evidence: Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18553213
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh
2015-01-01
Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
Pires, RES; Pereira, AA; Abreu-e-Silva, GM; Labronici, PJ; Figueiredo, LB; Godoy-Santos, AL; Kfuri, M
2014-01-01
Background: Foot and ankle injuries are frequent in emergency departments. Although only a few patients with foot and ankle sprain present fractures and the fracture patterns are almost always simple, lack of fracture diagnosis can lead to poor functional outcomes. Aim: The present study aims to evaluate the reliability of the Ottawa ankle rules and the orthopedic surgeon subjective perception to assess foot and ankle fractures after sprains. Subjects and Methods: A cross-sectional study was conducted from July 2012 to December 2012. Ethical approval was granted. Two hundred seventy-four adult patients admitted to the emergency department with foot and/or ankle sprain were evaluated by an orthopedic surgeon who completed a questionnaire prior to radiographic assessment. The Ottawa ankle rules and subjective perception of foot and/or ankle fractures were evaluated on the questionnaire. Results: Thirteen percent (36/274) patients presented fracture. Orthopedic surgeon subjective analysis showed 55.6% sensitivity, 90.1% specificity, 46.5% positive predictive value and 92.9% negative predictive value. The general orthopedic surgeon opinion accuracy was 85.4%. The Ottawa ankle rules presented 97.2% sensitivity, 7.8% specificity, 13.9% positive predictive value, 95% negative predictive value and 19.9% accuracy respectively. Weight-bearing inability was the Ottawa ankle rule item that presented the highest reliability, 69.4% sensitivity, 61.6% specificity, 63.1% accuracy, 21.9% positive predictive value and 93% negative predictive value respectively. Conclusion: The Ottawa ankle rules showed high reliability for deciding when to take radiographs in foot and/or ankle sprains. Weight-bearing inability was the most important isolated item to predict fracture presence. Orthopedic surgeon subjective analysis to predict fracture possibility showed a high specificity rate, representing a confident method to exclude unnecessary radiographic exams. PMID:24971221
2013-01-01
Background Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Results Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Conclusions Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard. PMID:24252243
Burke, Elinor; Grobler, Mariana; Elderfield, Kay; Bond, Frances; Crocker, Matthew; Taylor, Rohan; Bridges, Leslie R
2013-06-10
Our aim was to develop a new protocol for MGMT immunohistochemistry with good agreement between observers and good correlation with molecular genetic tests of tumour methylation. We examined 40 primary brain tumours (30 glioblastomas and 10 oligodendroglial tumours) with our new technique, namely double-labelling immunohistochemistry for MGMT and a "cocktail" of non-tumour antigens (CD34, CD45 and CD68). We compared the results with single-labelling immunohistochemistry for MGMT and methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA, a recognised molecular genetic technique which we applied as the gold-standard for the methylation status). Double-labelling immunohistochemistry for MGMT produced a visual separation of tumourous and non-tumourous elements on the same histological slide, making it quick and easy to determine whether tumour cell nuclei were MGMT-positive or MGMT-negative (and thereby infer the methylation status of the tumour). We found good agreement between observers (kappa 0.76) and within observer (kappa 0.84). Furthermore, double-labelling showed good specificity (80%), sensitivity (73.33%), positive predictive value (PPV, 83.33%) and negative predictive value (NPV, 68.75%) compared to MS-MLPA. Double-labelling was quicker and easier to assess than single-labelling and it outperformed quantitative computerised image analysis of MGMT single-labelling in terms of sensitivity, specificity, PPV and NPV. Double-labelling immunohistochemistry for MGMT and a cocktail of non-tumourous elements provides a "one look" method for determining whether tumour cell nuclei are MGMT-positive or MGMT-negative. This can be used to infer the methylation status of the tumour. There is good observer agreement and good specificity, sensitivity, PPV and NPV compared to a molecular gold-standard.
Khan, Iqbal Hassan; Sayeed, M. Abu; Sultana, Nishat; Islam, Kamrul; Amin, Jakia; Faruk, M. Omar; Khan, Umama; Khanam, Farhana; Ryan, Edward T.
2016-01-01
Enteric fever is a systemic infection caused by typhoidal strains of Salmonella enterica and is a significant cause of mortality and morbidity in many parts of the world, especially in resource-limited areas. Unfortunately, currently available diagnostic tests for enteric fever lack sensitivity and/or specificity. No true clinically practical gold standard for diagnosing patients with enteric fever exists. Unfortunately, microbiologic culturing of blood is only 30 to 70% sensitive although 100% specific. Here, we report the development of a lateral-flow immunochromatographic dipstick assay based on the detection of Salmonella enterica serovar Typhi (S. Typhi) lipopolysaccharide (LPS)-specific IgG in lymphocyte culture secretion. We tested the assay using samples from 142 clinically suspected enteric fever patients, 28 healthy individuals residing in a zone where enteric fever is endemic, and 35 patients with other febrile illnesses. In our analysis, the dipstick detected all blood culture-confirmed S. Typhi cases (48/48) and 5 of 6 Salmonella enterica serovar Paratyphi A blood cultured-confirmed cases. The test was negative in all 35 individuals febrile with other illnesses and all 28 healthy controls from the zone of endemicity. The test was positive in 19 of 88 individuals with suspected enteric fever but with negative blood cultures. Thus, the dipstick had a sensitivity of 98% compared to blood culture results and a specificity that ranged from 78 to 100% (95% confidence interval [CI], 70 to 100%), depending on the definition of a true negative. These results suggest that this dipstick assay can be very useful for the detection of enteric fever patients especially in regions of endemicity. PMID:26961857
Real-Time Elicitation of Moral Emotions Using a Prejudice Paradigm
Fourie, Melike M.; Kilchenmann, Nadine; Malcolm-Smith, Susan; Thomas, Kevin G. F.
2012-01-01
Moral emotions are critically important in guiding appropriate social conduct. Empirical investigation of these emotions remains a challenge, however, because of the difficulty in eliciting them reliably in controlled settings. Here we describe a novel prejudice paradigm that aimed to elicit both negatively and positively valenced moral emotions in real-time. Low-prejudice females (N = 46) who met highly specific demographic and personality-based screening criteria completed a series of Implicit Association Tests (IATs). Feedback following these IATs was pre-programmed to either endorse participants’ non-prejudiced self-standards (positive condition), or to contradict their self-standards (negative condition), in response to sensitive social topics. Neutral condition IATs reflected participants’ attitudes toward non-sensitive social topics. Results demonstrated that the IATs were successful in eliciting moral-positive emotions (satisfaction and pride) and moral-negative emotions (primarily guilt). In addition, participants high in self-reported punishment sensitivity, as assessed by the Behavioral Inhibition System (BIS) scale, reported greater guilt. PMID:22888322
Real-time elicitation of moral emotions using a prejudice paradigm.
Fourie, Melike M; Kilchenmann, Nadine; Malcolm-Smith, Susan; Thomas, Kevin G F
2012-01-01
Moral emotions are critically important in guiding appropriate social conduct. Empirical investigation of these emotions remains a challenge, however, because of the difficulty in eliciting them reliably in controlled settings. Here we describe a novel prejudice paradigm that aimed to elicit both negatively and positively valenced moral emotions in real-time. Low-prejudice females (N = 46) who met highly specific demographic and personality-based screening criteria completed a series of Implicit Association Tests (IATs). Feedback following these IATs was pre-programmed to either endorse participants' non-prejudiced self-standards (positive condition), or to contradict their self-standards (negative condition), in response to sensitive social topics. Neutral condition IATs reflected participants' attitudes toward non-sensitive social topics. Results demonstrated that the IATs were successful in eliciting moral-positive emotions (satisfaction and pride) and moral-negative emotions (primarily guilt). In addition, participants high in self-reported punishment sensitivity, as assessed by the Behavioral Inhibition System (BIS) scale, reported greater guilt.
Park, Lora E
2007-04-01
Appearance-Based Rejection Sensitivity (Appearance-RS) is a personality-processing system characterized by anxious concerns and expectations about being rejected based on one's physical attractiveness. People differ in their sensitivity to rejection based on appearance, with consequences for mental and physical health, self-esteem, affect, and feelings of belonging. Study 1 describes the development and validation of the Appearance-RS scale, its relation to personality variables and to health-related outcomes. Study 2 provides experimental evidence that high Appearance-RS people feel more alone and rejected when asked to think about negative aspects of their appearance. Finally, Study 3 tests ways to reduce the negative effects of receiving an appearance threat among high Appearance-RS participants. Specifically, high Appearance-RS participants who engaged in self-affirmation (thought of their personal strengths) or received a secure attachment prime (thought of a close, caring relationship) were buffered from the negative effects of an appearance threat on subsequent state self-esteem and mood.
ERIC Educational Resources Information Center
Shamblen, Stephen R.; Springer, J. Fred
2007-01-01
There is an absence of systematic, comparative research examining the negative consequences that are experienced as a result of using specific substances. Further, techniques typically used for needs assessment (i.e., prevalence proportions) do not take into account the probability of experiencing a negative consequence as a result of using…
Chen, Chia-Wei; Chu, Hsin; Tsai, Chia-Fen; Yang, Hui-Ling; Tsai, Jui-Chen; Chung, Min-Huey; Liao, Yuan-Mei; Chi, Mei-Ju; Chou, Kuei-Ru
2015-11-01
The purpose of this study was to translate the Rowland Universal Dementia Assessment Scale into Chinese and to evaluate the psychometric properties (reliability and validity) and the diagnostic properties (sensitivity, specificity and predictive values) of the Chinese version of the Rowland Universal Dementia Assessment Scale. The accurate detection of early dementia requires screening tools with favourable cross-cultural linguistic and appropriate sensitivity, specificity, and predictive values, particularly for Chinese-speaking populations. This was a cross-sectional, descriptive study. Overall, 130 participants suspected to have cognitive impairment were enrolled in the study. A test-retest for determining reliability was scheduled four weeks after the initial test. Content validity was determined by five experts, whereas construct validity was established by using contrasted group technique. The participants' clinical diagnoses were used as the standard in calculating the sensitivity, specificity, positive predictive value and negative predictive value. The study revealed that the Chinese version of the Rowland Universal Dementia Assessment Scale exhibited a test-retest reliability of 0.90, an internal consistency reliability of 0.71, an inter-rater reliability (kappa value) of 0.88 and a content validity index of 0.97. Both the patients and healthy contrast group exhibited significant differences in their cognitive ability. The optimal cut-off points for the Chinese version of the Rowland Universal Dementia Assessment Scale in the test for mild cognitive impairment and dementia were 24 and 22, respectively; moreover, for these two conditions, the sensitivities of the scale were 0.79 and 0.76, the specificities were 0.91 and 0.81, the areas under the curve were 0.85 and 0.78, the positive predictive values were 0.99 and 0.83 and the negative predictive values were 0.96 and 0.91 respectively. The Chinese version of the Rowland Universal Dementia Assessment Scale exhibited sound reliability, validity, sensitivity, specificity and predictive values. This scale can help clinical staff members to quickly and accurately diagnose cognitive impairment and provide appropriate treatment as early as possible. © 2015 John Wiley & Sons Ltd.
McCusker, J J; McCoy, E L; Young, C L; Alamares, R; Hirsch, L S
1984-01-01
The Directigen Group A Strep Test (DGAST), a new rapid method of detecting group A beta-hemolytic streptococci directly from throat swabs, was compared with a traditional culture technique for the detection of group A beta-hemolytic streptococci. Five hundred oropharyngeal swabs from pediatric and adult patients were cultured and then processed by using the DGAST. Of the 144 specimens positive by culture, 131 were DGAST positive (sensitivity, 90.9%). Of the 356 specimens negative by culture, 353 were DGAST negative (specificity, 99.2%). Twelve of the 13 false-negative DGAST results were from pediatric patients. One hundred isolates of non-group A beta-hemolytic streptococci were recovered, primarily groups C, F, and G. The DGAST is easy to perform, rapid, sensitive, and very specific for detection of group A beta-hemolytic streptococci directly from swabs. Supplementing the DGAST with a culture on a 5% sheep blood agar plate would enhance detection of group A beta-hemolytic streptococci, especially in pediatric patients. PMID:6386884
Algorithms for detecting antibodies to HIV-1: results from a rural Ugandan cohort.
Nunn, A J; Biryahwaho, B; Downing, R G; van der Groen, G; Ojwiya, A; Mulder, D W
1993-08-01
To evaluate an algorithm using two enzyme immunoassays (EIA) for anti-HIV-1 antibodies in a rural African population and to assess alternative simplified algorithms. Sera obtained from 7895 individuals in a rural population survey were tested using an algorithm based on two different EIA systems: Recombigen HIV-1 EIA and Wellcozyme HIV-1 Recombinant. Alternative algorithms were assessed using negative or confirmed positive sera. None of the 227 sera classified as unequivocably negative by the two assays were positive by Western blot. Of 192 sera unequivocably positive by both assays, four were seronegative by Western blot. The possibility of technical error cannot be ruled out in three of these. One of the alternative algorithms assessed classified all borderline or discordant assay results as negative had a specificity of 100% and a sensitivity of 98.4%. The cost of this algorithm is one-third that of the conventional algorithm. Our evaluation suggests that high specificity and sensitivity can be obtained without using Western blot and at a considerable reduction in cost.
Huang, Terry T-K; Nansel, Tonja R; Belsheim, Allen R; Morrison, John A
2008-02-01
To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoff points in relation to adult MetS. Data from the National Heart, Lung, and Blood Institute Lipid Research Clinics Princeton Prevalence Study (1973-1976) and the Princeton Follow-up Study (2000-2004) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff point and for aggregates of components. Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all 5 pediatric MetS components were considered, the presence of at least 1 abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Considering multiple metabolic variables in childhood can improve the predictive usefulness for adult MetS, compared with each component or body mass alone. MetS variables may be useful for identifying some children who are at risk for prevention interventions.
The accuracy of burn diagnosis codes in health administrative data: A validation study.
Mason, Stephanie A; Nathens, Avery B; Byrne, James P; Fowler, Rob; Gonzalez, Alejandro; Karanicolas, Paul J; Moineddin, Rahim; Jeschke, Marc G
2017-03-01
Health administrative databases may provide rich sources of data for the study of outcomes following burn. We aimed to determine the accuracy of International Classification of Diseases diagnoses codes for burn in a population-based administrative database. Data from a regional burn center's clinical registry of patients admitted between 2006-2013 were linked to administrative databases. Burn total body surface area (TBSA), depth, mechanism, and inhalation injury were compared between the registry and administrative records. The sensitivity, specificity, and positive and negative predictive values were determined, and coding agreement was assessed with the kappa statistic. 1215 burn center patients were linked to administrative records. TBSA codes were highly sensitive and specific for ≥10 and ≥20% TBSA (89/93% sensitive and 95/97% specific), with excellent agreement (κ, 0.85/κ, 0.88). Codes were weakly sensitive (68%) in identifying ≥10% TBSA full-thickness burn, though highly specific (86%) with moderate agreement (κ, 0.46). Codes for inhalation injury had limited sensitivity (43%) but high specificity (99%) with moderate agreement (κ, 0.54). Burn mechanism had excellent coding agreement (κ, 0.84). Administrative data diagnosis codes accurately identify burn by burn size and mechanism, while identification of inhalation injury or full-thickness burns is less sensitive but highly specific. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Berneder, M.; Bublin, M.; Hoffmann-Sommergruber, K.; Hawranek, T.; Lang, R.
2016-01-01
Background Gly m 5 and Gly m 6 are known to induce severe reactions in soy-allergic patients. For birch pollen (BP)-allergic patients, the Bet v 1 homologous allergen Gly m 4 is also a potential trigger of generalized severe reactions upon soy consumption. Therefore, reliable component-resolved diagnosis of soy allergy is needed. Methods IgE reactivity from sera of 20 patients from a BP environment with reported soy allergy was assessed. Skin prick tests (SPT) with BP and soy drink were performed. Specific IgE for BP, soy, Bet v 1 and Gly m 4 was analyzed by ImmunoCAP. In addition, ISAC microarray profiling was performed. Results Nineteen of 20 patients were BP allergic (positive SPT and/or CAP results for BP extract and Bet v 1). Eighteen soy-allergic patients were tested positive with soy drink in SPT. Soy CAP results were negative in the majority of tests (15/20), whereas 19/20 sera had specific IgE to Gly m 4. In the microarray approach, 14/20 sera displayed Gly m 4-specific IgE, the additional 6 sera had IgE levels below 0.3 ISAC standardized units. The BP-negative serum had Gly m 5- and Gly m 6-specific IgE which correlated with positive soy ImmunoCAP. Conclusions Soy sensitization detected by SPT and Gly m 4 ImmunoCAP were in good qualitative agreement with ISAC results. Soy ImmunoCAP was only specific for Gly m 5 and Gly m 6 sensitization. Gly m 4 ImmunoCAP has a higher sensitivity than ImmunoCAP ISAC. In this patient cohort, Gly m 4 sensitization was linked to the development of severe and generalized allergic reactions upon soy consumption. PMID:23548307
Lim, T K; Gough, A; Chin, N K; Kumarasinghe, G
2000-09-01
The AMPLICOR assay (Roche; Branchburg, NJ), a rapid direct amplification test for Mycobacterium tuberculosis, has only been licensed for use in smear-positive respiratory specimens. However, many patients with pulmonary tuberculosis (PTB) have smear-negative disease. The clinical utility of this test in patients with smear-negative PTB is unknown. To evaluate the effect of pretest probability of PTB estimated by chest physicians on the accuracy of the AMPLICOR assay in patients with smear-negative PTB. A prospective study of consecutive patients suspected of having smear-negative PTB. Two chest physicians estimated the pretest probability of active disease (high, intermediate, and low categories). Respiratory specimens were examined with radiometric broth medium cultures and with the AMPLICOR assay for M tuberculosis. The decision on a final diagnosis of PTB was blinded to the AMPLICOR results. Active PTB was diagnosed in 25 of 441 patients (5.7%). The AMPLICOR assay had an overall sensitivity of 44% and a specificity of 99%. Results of the assay were negative in seven patients with culture-negative PTB. The proportions of patients in the high, intermediate, and low pretest groups were 4.5%, 19.7%, and 75.7%, respectively. The incidence of PTB for each group was 95%, 3.4%, and 0.9%, respectively. The sensitivities of the AMPLICOR assay in the three groups of patients were 47%, 33%, and 33%, respectively, while the specificities were 100%, 98%, and 99%, respectively. In patients suspected of having smear-negative PTB, the following conclusions were drawn: (1) the incidence of active PTB was low; (2) pretest estimates accurately discriminated between patients with high and low risk of PTB; (3) the risk of PTB was overestimated in the intermediate group; and (4) the utility of the AMPLICOR assay in the intermediate-risk group may be limited by the overestimation of disease prevalence and low test sensitivity. Further studies are needed on the role of the AMPLICOR assay in better selected patients with an intermediate risk of having smear-negative PTB.
Kobayashi, Naomi; Bauer, Thomas W; Togawa, Daisuke; Lieberman, Isador H; Sakai, Hiroshige; Fujishiro, Takaaki; Tuohy, Marion J; Procop, Gary W
2005-06-01
The bacteria associated with orthopaedic infections are usually common gram-positive and gram-negative bacteria. This fundamental grouping of bacteria is a necessary first step in the selection of appropriate antibiotics. Since polymerase chain reaction (PCR) is more rapid and may be more sensitive than culture, we developed a postamplification pyrosequencing method to subcategorize bacteria based on a few nucleotide polymorphisms in the 16S rRNA gene. We validated this method using well-characterized strains of bacteria and applied it to specimens from spinal surgery cases with suspected infections. Lysates of 114 bacteria including 75 species were created following standard cultivation to obtain DNA. The DNA was amplified by a broad-range real-time PCR. The amplicons were evaluated by pyrosequencing and were classified as gram-positive, gram-negative, or acid-fast bacilli based on the first three to five nucleotides sequenced. In addition, clinical cases of suspected infection were obtained from spinal surgery. The results of the "molecular Gram stain" were compared with the results of traditional Gram stain and culture. The lysates of 107 (93.9%) of the bacteria extracts tested were appropriately categorized as gram-positive and gram-negative or as acid-fast bacilli on the basis of this assay. The sensitivity and specificity of this assay were 100% and 97.4% for gram-positive and 88.3% and 100% for gram-negative isolates. All of the five clinical samples were appropriately categorized as containing gram-positive or gram-negative bacteria with this assay. This study demonstrates that high sensitivity and specificity of a molecular gram stain may be achieved using broad-range real-time PCR and pyrosequencing.
Chihara, Shingo; Hayden, Mary K.; Minogue-Corbett, Eileen; Singh, Kamaljit
2009-01-01
The ability to rapidly differentiate coagulase-negative staphylococcus (CoNS) from Staphylococcus aureus and to determine methicillin resistance is important as it affects the decision to treat empiric antibiotic selection. The objective of this study was to evaluate CHROMagar S. aureus and CHROMagar MRSA (Becton Dickinson) for rapid identification of Staphylococcus spp. directly from blood cultures. Consecutive blood culture bottles (BacT Alert 3D SA and SN, bioMérieux) growing gram-positive cocci in clusters were evaluated. An aliquot was plated onto CHROMagar MRSA (C-MRSA) and CHROMagar S. aureus (C-SA) plates, which were read at 12 to 16 hours. C-SA correctly identified 147/147 S. aureus (100% sensitivity); 2 CoNS were misidentified as S. aureus (98% specificity). C-MRSA correctly identified 74/77 MRSA (96% sensitivity). None of the MSSA isolates grew on C-MRSA (100% specificity). In conclusion, CHROMagar is a rapid and sensitive method to distinguish MRSA, MSSA, and coagulase-negative Staphylococcus and may decrease time of reporting positive results. PMID:20016679
NASA Astrophysics Data System (ADS)
de Siqueira e Oliveira, Fernanda S.; Giana, Hector E.; Silveira, Landulfo, Jr.
2012-03-01
It has been proposed a method based on Raman spectroscopy for identification of different microorganisms involved in bacterial urinary tract infections. Spectra were collected from different bacterial colonies (Gram negative: E. coli, K. pneumoniae, P. mirabilis, P. aeruginosa, E. cloacae and Gram positive: S. aureus and Enterococcus sp.), grown in culture medium (Agar), using a Raman spectrometer with a fiber Raman probe (830 nm). Colonies were scraped from Agar surface placed in an aluminum foil for Raman measurements. After pre-processing, spectra were submitted to a Principal Component Analysis and Mahalanobis distance (PCA/MD) discrimination algorithm. It has been found that the mean Raman spectra of different bacterial species show similar bands, being the S. aureus well characterized by strong bands related to carotenoids. PCA/MD could discriminate Gram positive bacteria with sensitivity and specificity of 100% and Gram negative bacteria with good sensitivity and high specificity.
Two-question depression-screeners - the solution to all problems?
Albani, Cornelia; Bailer, Harald; Blaser, Gerd; Brähler, Elmar; Geyer, Michael; Grulke, Norbert
2006-04-01
Depression constitutes a considerable issue in medicine and it is anticipated that the amount of people suffering from affective disorders will increase significantly. It would be useful to have a simple, fast screening procedure which would help detect depression. In four recently published articles a two-question depression-screener is recommended. Sensitivity, specificity, likelihood ratios, negative and positive predictive values were compared. For four different clinical samples and one sample that was representative of the German population the prevalence for depression ranged from 6.9 % to 18.1 %. Sensitivity and specificity reached values from 72.6 % to 96.6 % and from 56.9 % to 90.0 % respectively. All negative predictive values were high (< 97 %) opposed to positive predictive values (17.8 % to 38.5 %). Overall, it seems that the two-question screenings are well suited for the exclusion of a major depression. It is possible that regular screening could further lower the percentage of undiagnosed cases.
[Echocardiographic diagnosis of atrial thrombosis].
Pinto Tortolero, R; Vargas Barrón, J; Rodas, M A; Díaz de la Vega, V; Horwitz, S
1982-01-01
Seventy patients with rheumatic mitral disease were studied by M-Mode and 2D echocardiography in order to detect left atrial thrombosis before surgery. Thrombosis were suspected by the observation of abnormal echoes in the left atrium. During surgery 17 (24%) patients had atrial thrombosis. It had been suspected by echocardiography in 12 (sensitivity 70%). In 53 patients thrombosis were not found during surgery; in 46 the echo had been also negative (specificity 86%). There was a false positive detection of thrombosis by echo in 7 patients (14%) and false negativity in 5 (30%). Patients with atrial thrombosis had atrial fibrilation in 91% of cases; and the most frequent valvular disease was mitral stenosis. There was not a direct relationship among existence of left atrial thrombosis and the anteroposterior diameter of the left atrium as measured by echo. We conclude that echocardiography has good specificity to rule out atrial thrombosis and moderate sensitivity to detect it in rheumatic mitral disease.
Cartoni, A; Lincoln, N B
2005-03-01
The aim of the study was to assess the sensitivity and specificity of the MEAMS (Golding, 1989) for detecting cognitive impairment after stroke. Stroke patients admitted to hospital received a cognitive screening assessment, the MEAMS, and a detailed cognitive assessment. The information obtained from the detailed assessment was summarised in a structured written report. From the conclusions in these reports, patients were classified as "impaired" or "not impaired" in perception, memory, executive function and language. The sensitivity and specificity of the MEAMS subtests and the overall number of tests passed were determined in relation to the presence of impairment, as given in the overall conclusion of the written reports. There were 30 stroke patients, aged 58 to 92 (mean 75.80, SD 7.94) years. Of these, 17 were men and 13 were women. The sensitivity of the MEAMS subtests ranged from 11% to 100% and the specificity ranged from 69% to 100%. The sensitivity of the overall MEAMS score was 52% and the specificity was 100%, using a cut-off score of 3 or more fails to indicate impairment. Three subtests, Orientation, Naming and Unusual views had 81% sensitivity and 50% specificity for detecting problems in language, perception or memory. The MEAMS was not a sensitive screen for overall cognitive impairment or for memory, perceptual, language, or executive function problems after stroke, but it was specific. Although screening for cognitive impairment is important, the MEAMS is not recommended as the sole method, as it produces an unacceptably high false negative rate. Three subtests (Orientation, Naming and Unusual views) had 81% sensitivity and 50% specificity for detecting cognitive problems in language, perception or memory after stroke.
Manning, Laurens; Laman, Moses; Rosanas-Urgell, Anna; Turlach, Berwin; Aipit, Susan; Bona, Cathy; Warrell, Jonathan; Siba, Peter; Mueller, Ivo; Davis, Timothy M E
2012-01-01
Although rapid diagnostic tests (RDTs) have practical advantages over light microscopy (LM) and good sensitivity in severe falciparum malaria in Africa, their utility where severe non-falciparum malaria occurs is unknown. LM, RDTs and polymerase chain reaction (PCR)-based methods have limitations, and thus conventional comparative malaria diagnostic studies employ imperfect gold standards. We assessed whether, using Bayesian latent class models (LCMs) which do not require a reference method, RDTs could safely direct initial anti-infective therapy in severe ill children from an area of hyperendemic transmission of both Plasmodium falciparum and P. vivax. We studied 797 Papua New Guinean children hospitalized with well-characterized severe illness for whom LM, RDT and nested PCR (nPCR) results were available. For any severe malaria, the estimated prevalence was 47.5% with RDTs exhibiting similar sensitivity and negative predictive value (NPV) to nPCR (≥96.0%). LM was the least sensitive test (87.4%) and had the lowest NPV (89.7%), but had the highest specificity (99.1%) and positive predictive value (98.9%). For severe falciparum malaria (prevalence 42.9%), the findings were similar. For non-falciparum severe malaria (prevalence 6.9%), no test had the WHO-recommended sensitivity and specificity of >95% and >90%, respectively. RDTs were the least sensitive (69.6%) and had the lowest NPV (96.7%). RDTs appear a valuable point-of-care test that is at least equivalent to LM in diagnosing severe falciparum malaria in this epidemiologic situation. None of the tests had the required sensitivity/specificity for severe non-falciparum malaria but the number of false-negative RDTs in this group was small.
Cheng, Hong; Macaluso, Maurizio; Vermund, Sten H.; Hook, Edward W.
2001-01-01
Published estimates of the sensitivity and specificity of PCR and ligase chain reaction (LCR) for detecting Chlamydia trachomatis are potentially biased because of study design limitations (confirmation of test results was limited to subjects who were PCR or LCR positive but culture negative). Relative measures of test accuracy are less prone to bias in incomplete study designs. We estimated the relative sensitivity (RSN) and relative false-positive rate (RFP) for PCR and LCR versus cell culture among 1,138 asymptomatic men and evaluated the potential bias of RSN and RFP estimates. PCR and LCR testing in urine were compared to culture of urethral specimens. Discordant results (PCR or LCR positive, but culture negative) were confirmed by using a sequence including the other DNA amplification test, direct fluorescent antibody testing, and a DNA amplification test to detect chlamydial major outer membrane protein. The RSN estimates for PCR and LCR were 1.45 (95% confidence interval [CI] = 1.3 to 1.7) and 1.49 (95% CI = 1.3 to 1.7), respectively, indicating that both methods are more sensitive than culture. Very few false-positive results were found, indicating that the specificity levels of PCR, LCR, and culture are high. The potential bias in RSN and RFP estimates were <5 and <20%, respectively. The estimation of bias is based on the most likely and probably conservative parameter settings. If the sensitivity of culture is between 60 and 65%, then the true sensitivity of PCR and LCR is between 90 and 97%. Our findings indicate that PCR and LCR are significantly more sensitive than culture, while the three tests have similar specificities. PMID:11682509
Hvidhjelm, Jacob; Sestoft, Dorte; Skovgaard, Lene Theil; Bue Bjorner, Jakob
2014-11-01
Violence and aggressive behavior within psychiatric facilities are serious work environment problems, which have negative consequences for both patients and staff. It is therefore of great importance to reduce both the number and the severity of these violent incidents to improve quality of care. To evaluate the specificity and sensitivity of the Brøset Violence Checklist (BVC) as a predictor of violent incidents for Danish forensic psychiatry patients. A total of 156 patients were assessed three times daily with the BVC for 24 months. All aggressive or violent incidents were recorded using the Staff Observation Aggression Scale-Revised (SOAS-R). SOAS-R scores of 9 or more defined violent incidents. Data were analyzed using standard logistic regression models as well as models incorporating a random person effect. We used receiver operating curve (ROC) analysis to evaluate different BVC thresholds. Of a total of 139,579 BVC registrations we found 1999 scores above 0 and 419 violent incidents. The BVC score was a strong predictor of violence. For the standard cut-off point of 3, specificity was 0.997 and sensitivity was 0.656. For the general risk of violence seen in this study, the risk of violence given a BVC score > 3 (positive predictive value) was 37.2%, and the risk of violence given a BVC score < 3 (negative predictive value) was 0.1%. The BVC showed satisfactory specificity and sensitivity as a predictor of the short-term risk of violence against staff and others by patients in a forensic setting.
Garcia, Jessica; Forestier, Julien; Dusserre, Eric; Wozny, Anne-Sophie; Geiguer, Florence; Merle, Patrick; Tissot, Claire; Ferraro-Peyret, Carole; Jones, Frederick S; Edelstein, Daniel L; Cheynet, Valérie; Bardel, Claire; Vilchez, Gaelle; Xu, Zhenyu; Bringuier, Pierre Paul; Barritault, Marc; Brengle-Pesce, Karen; Guillet, Marielle; Chauvenet, Marion; Manship, Brigitte; Brevet, Marie; Rodriguez-Lafrasse, Claire; Hervieu, Valérie; Couraud, Sébastien; Walter, Thomas; Payen, Léa
2018-04-20
CfDNA samples from colon (mCRC) and non-small cell lung cancers (NSCLC) (CIRCAN cohort) were compared using three platforms: droplet digital PCR (ddPCR, Biorad); BEAMing/OncoBEAM™-RAS-CRC (Sysmex Inostics); next-generation sequencing (NGS, Illumina), utilizing the 56G oncology panel (Swift Biosciences). Tissue biopsy and time matched cfDNA samples were collected at diagnosis in the mCRC cohort and during 1st progression in the NSCLC cohort. Excellent matches between cfDNA/FFPE mutation profiles were observed. Detection thresholds were between 0.5-1% for cfDNA samples examined using ddPCR and NGS, and 0.03% with BEAMing. This high level of sensitivity enabled the detection of KRAS mutations in 5/19 CRC patients with negative FFPE profiles. In the mCRC cohort, comparison of mutation results obtained by testing FFPE to those obtained by testing cfDNA by ddPCR resulted in 47% sensitivity, 77% specificity, 70% positive predictive value (PPV) and 55% negative predictive value (NPV). For BEAMing, we observed 93% sensitivity, 69% specificity, 78% PPV and 90% NPV. Finally, sensitivity of NGS was 73%, specificity was 77%, PPV 79% and NPV 71%. Our study highlights the complementarity of different diagnostic approaches and variability of results between OncoBEAM™-RAS-CRC and NGS assays. While the NGS assay provided a larger breadth of coverage of the major targetable alterations of 56 genes in one run, its performance for specific alterations was frequently confirmed by ddPCR results.
Garcia, Jessica; Forestier, Julien; Dusserre, Eric; Wozny, Anne-Sophie; Geiguer, Florence; Merle, Patrick; Tissot, Claire; Ferraro-Peyret, Carole; Jones, Frederick S.; Edelstein, Daniel L.; Cheynet, Valérie; Bardel, Claire; Vilchez, Gaelle; Xu, Zhenyu; Bringuier, Pierre Paul; Barritault, Marc; Brengle-Pesce, Karen; Guillet, Marielle; Chauvenet, Marion; Manship, Brigitte; Brevet, Marie; Rodriguez-Lafrasse, Claire; Hervieu, Valérie; Couraud, Sébastien; Walter, Thomas; Payen, Léa
2018-01-01
CfDNA samples from colon (mCRC) and non-small cell lung cancers (NSCLC) (CIRCAN cohort) were compared using three platforms: droplet digital PCR (ddPCR, Biorad); BEAMing/OncoBEAM™-RAS-CRC (Sysmex Inostics); next-generation sequencing (NGS, Illumina), utilizing the 56G oncology panel (Swift Biosciences). Tissue biopsy and time matched cfDNA samples were collected at diagnosis in the mCRC cohort and during 1st progression in the NSCLC cohort. Excellent matches between cfDNA/FFPE mutation profiles were observed. Detection thresholds were between 0.5–1% for cfDNA samples examined using ddPCR and NGS, and 0.03% with BEAMing. This high level of sensitivity enabled the detection of KRAS mutations in 5/19 CRC patients with negative FFPE profiles. In the mCRC cohort, comparison of mutation results obtained by testing FFPE to those obtained by testing cfDNA by ddPCR resulted in 47% sensitivity, 77% specificity, 70% positive predictive value (PPV) and 55% negative predictive value (NPV). For BEAMing, we observed 93% sensitivity, 69% specificity, 78% PPV and 90% NPV. Finally, sensitivity of NGS was 73%, specificity was 77%, PPV 79% and NPV 71%. Our study highlights the complementarity of different diagnostic approaches and variability of results between OncoBEAM™-RAS-CRC and NGS assays. While the NGS assay provided a larger breadth of coverage of the major targetable alterations of 56 genes in one run, its performance for specific alterations was frequently confirmed by ddPCR results. PMID:29765524
Tang, Lin-Quan; Zhang, Hua; Li, Yan; Liu, Wan-Li; Zhong, Qian; Zeng, Mu-Sheng; Huang, Xiao-Ming
2016-01-01
To determine whether measuring antibodies against Epstein-Barr virus (EBV) glycoprotein gH/gL in serum could improve diagnostic accuracy in nasopharyngeal carcinoma (NPC) cases, gH/gL expressed in a recombinant baculovirus system was used in an enzyme-linked immunosorbent assay (ELISA) to detect antibodies in two independent cohorts. Binary logistic regression analyses were performed using results from a training cohort (n = 406) to establish diagnostic mathematical models, which were validated in a second independent cohort (n = 279). Levels of serum gH/gL antibodies were higher in NPC patients than in healthy controls (p < 0.001). In the training cohort, the IgA-gH/gL ELISA had a sensitivity of 83.7%, specificity of 82.3% and area under the curve (AUC) of 0.893 (95% CI, 0.862-0.924) for NPC diagnosis. Furthermore, gH/gL maintained diagnostic capacity in IgA-VCA negative NPC patients (sensitivity = 78.1%, specificity = 82.3%, AUC = 0.879 [95% CI, 0.820 - 0.937]). Combining gH/gL and viral capsid antigen (VCA) detection improved diagnostic capacity as compared to individual tests alone in both the training cohort (sensitivity = 88.5%, specificity = 97%, AUC = 0.98 [95% CI, 0.97 - 0.991]), and validation cohort (sensitivity = 91.2%, specificity = 96.5%, AUC = 0.97 [95% CI, 0.951-0.988]). These findings suggest that EBV gH/gL detection complements VCA detection in the diagnosis of NPC and aids in the identification of patients with VCA-negative NPC. PMID:27093005
Sensitivity and Specificity of Eustachian Tube Function Tests in Adults
Doyle, William J.; Swarts, J. Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M.
2013-01-01
Objective Determine if Eustachian Tube (ET) function (ETF) tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and define the inter-relatedness of ETF test parameters. Methods ETF was evaluated using the Forced-Response, Inflation-Deflation, Valsalva and Sniffing tests in 15 control ears of adult subjects after unilateral myringotomy (Group I) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (Group II). Data were analyzed using logistic regression including each parameter independently and then a step-down Discriminant Analysis including all ETF test parameters to predict group assignment. Factor Analysis operating over all parameters was used to explore relatedness. Results The Discriminant Analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency and % positive pressure equilibrated) that together correctly assigned ears to Group II at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters, the first had negative loadings of the ETF structural parameters, the second had positive loadings of the muscle-assisted ET opening parameters and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. Discussion These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories. PMID:23868429
Banal, Frédéric; Gandjbakhch, Frédérique; Foltz, Violaine; Goldcher, Alain; Etchepare, Fabien; Rozenberg, Sylvie; Koeger, Anne-Claude; Bourgeois, Pierre; Fautrel, Bruno
2009-08-01
To date, early diagnosis of stress fractures depends on magnetic resonance imaging (MRI) or bone scan scintigraphy, as radiographs are usually normal at onset of symptoms. These examinations are expensive or invasive, time-consuming, and poorly accessible. A recent report has shown the ability of ultrasonography (US) to detect early stress fractures. Our objective was to evaluate sensitivity and specificity of US versus dedicated MRI (0.2 Tesla), taken as the gold standard, in early diagnosis of metatarsal bone stress fractures. A case-control study from November 2006 to December 2007 was performed. All consecutive patients with mechanical pain and swelling of the metatarsal region for less than 3 months and with normal radiographs were included. US and dedicated MRI examinations of the metatarsal bones were performed the same day by experienced rheumatologists with expertise in US and MRI. Reading was undertaken blind to the clinical assessment and MRI/US results. Forty-one feet were analyzed on US and dedicated MRI from 37 patients (28 women, 9 men, mean age 52.7 +/- 14.1 yrs). MRI detected 13 fractures in 12 patients. Sensitivity of US was 83%, specificity 76%, positive predictive value 59%, and negative predictive value 92%. Positive likehood ratio was 3.45, negative likehood ratio 0.22. In cases of normal radiographs, US is indicated in the diagnosis of metatarsal bone stress fractures, as it is a low cost, noninvasive, rapid, and easy technique with good sensitivity and specificity. From these data, we propose a new imaging algorithm including US.
Tiet, Quyen Q; Leyva, Yani; Moos, Rudolf H; Smith, Brandy
2016-07-01
The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST) is a screening instrument to detect substance use in primary care (PC). To screen for illicit substances (excluding tobacco and alcohol), the ASSIST consists of 8-57 questions and requires complicated scoring. To improve the efficiency of screening of drug misuse in PC, this study constructed and validated a two-item screen for drug use from the ASSIST. Guided by previous reviews, the ASSIST was revised. Patients were recruited in VA primary care clinics (N=1283). Half of the sample was used to develop the ASSIST-Drug; the other half was used to validate it. The Mini International Neuropsychiatric Interview (MINI) and the Inventory of Drug Use Consequences were the criterion measures. A brief, two-item ASSIST-Drug was constructed. Based on the development sample, the ASSIST-Drug was 94.1% sensitive and 89.6% specific for drug use disorders. Based on the validation sample, it was 95.4% sensitive and 87.8% specific. The ASSIST-Drug also had comparable sensitivity and specificity to identify drug use negative consequences, as well as for diverse subgroups of patients in terms of gender, age, race/ethnicity, marital status, educational levels, and post traumatic stress disorder status. The ASSIST-Drug may be a useful screening tool for PC settings. It is reliable, brief, and easy to remember, administer and score. It is sensitive and specific for drug use disorders and drug use negative consequences, and the predictive properties are consistent across subgroup of patients. Published by Elsevier Ireland Ltd.
The PHQ-PD as a Screening Tool for Panic Disorder in the Primary Care Setting in Spain
Wood, Cristina Mae; Ruíz-Rodríguez, Paloma; Tomás-Tomás, Patricia; Gracia-Gracia, Irene; Dongil-Collado, Esperanza; Iruarrizaga, M. Iciar
2016-01-01
Introduction Panic disorder is a common anxiety disorder and is highly prevalent in Spanish primary care centres. The use of validated tools can improve the detection of panic disorder in primary care populations, thus enabling referral for specialized treatment. The aim of this study is to determine the accuracy of the Patient Health Questionnaire-Panic Disorder (PHQ-PD) as a screening and diagnostic tool for panic disorder in Spanish primary care centres. Method We compared the psychometric properties of the PHQ-PD to the reference standard, the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview. General practitioners referred 178 patients who completed the entire PHQ test, including the PHQ-PD, to undergo the SCID-I. The sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios of the PHQ-PD were assessed. Results The operating characteristics of the PHQ-PD are moderate. The best cut-off score was 5 (sensitivity .77, specificity .72). Modifications to the questionnaire's algorithms improved test characteristics (sensitivity .77, specificity .72) compared to the original algorithm. The screening question alone yielded the highest sensitivity score (.83). Conclusion Although the modified algorithm of the PHQ-PD only yielded moderate results as a diagnostic test for panic disorder, it was better than the original. Using only the first question of the PHQ-PD showed the best psychometric properties (sensitivity). Based on these findings, we suggest the use of the screening questions for screening purposes and the modified algorithm for diagnostic purposes. PMID:27525977
Meghdadi, Hossein; Khosravi, Azar D.; Ghadiri, Ata A.; Sina, Amir H.; Alami, Ameneh
2015-01-01
Present study was aimed to examine the diagnostic utility of polymerase chain reaction (PCR) and nested PCR techniques for the detection of Mycobacterium tuberculosis (MTB) DNA in samples from patients with extra pulmonary tuberculosis (EPTB). In total 80 formalin-fixed, paraffin-embedded (FFPE) samples comprising 70 samples with definite diagnosis of EPTB and 10 samples from known non- EPTB on the basis of histopathology examination, were included in the study. PCR amplification targeting IS6110, rpoB gene and nested PCR targeting the rpoB gene were performed on the extracted DNAs from 80 FFPE samples. The strong positive samples were directly sequenced. For negative samples and those with weak band in nested-rpoB PCR, TA cloning was performed by cloning the products into the plasmid vector with subsequent sequencing. The 95% confidence intervals (CI) for the estimates of sensitivity and specificity were calculated for each method. Fourteen (20%), 34 (48.6%), and 60 (85.7%) of the 70 positive samples confirmed by histopathology, were positive by rpoB-PCR, IS6110-PCR, and nested-rpoB PCR, respectively. By performing TA cloning on samples that yielded weak (n = 8) or negative results (n = 10) in the PCR methods, we were able to improve their quality for later sequencing. All samples with weak band and 7 out of 10 negative samples, showed strong positive results after cloning. So nested-rpoB PCR cloning revealed positivity in 67 out of 70 confirmed samples (95.7%). The sensitivity of these combination methods was calculated as 95.7% in comparison with histopathology examination. The CI for sensitivity of the PCR methods were calculated as 11.39–31.27% for rpoB-PCR, 36.44–60.83% for IS6110- PCR, 75.29–92.93% for nested-rpoB PCR, and 87.98–99.11% for nested-rpoB PCR cloning. The 10 true EPTB negative samples by histopathology, were negative by all tested methods including cloning and were used to calculate the specificity of the applied methods. The CI for 100% specificity of each PCR method were calculated as 69.15–100%. Our results indicated that nested-rpoB PCR combined with TA cloning and sequencing is a preferred method for the detection of MTB DNA in EPTB samples with high sensitivity and specificity which confirm the histopathology results. PMID:26191059
Meghdadi, Hossein; Khosravi, Azar D; Ghadiri, Ata A; Sina, Amir H; Alami, Ameneh
2015-01-01
Present study was aimed to examine the diagnostic utility of polymerase chain reaction (PCR) and nested PCR techniques for the detection of Mycobacterium tuberculosis (MTB) DNA in samples from patients with extra pulmonary tuberculosis (EPTB). In total 80 formalin-fixed, paraffin-embedded (FFPE) samples comprising 70 samples with definite diagnosis of EPTB and 10 samples from known non- EPTB on the basis of histopathology examination, were included in the study. PCR amplification targeting IS6110, rpoB gene and nested PCR targeting the rpoB gene were performed on the extracted DNAs from 80 FFPE samples. The strong positive samples were directly sequenced. For negative samples and those with weak band in nested-rpoB PCR, TA cloning was performed by cloning the products into the plasmid vector with subsequent sequencing. The 95% confidence intervals (CI) for the estimates of sensitivity and specificity were calculated for each method. Fourteen (20%), 34 (48.6%), and 60 (85.7%) of the 70 positive samples confirmed by histopathology, were positive by rpoB-PCR, IS6110-PCR, and nested-rpoB PCR, respectively. By performing TA cloning on samples that yielded weak (n = 8) or negative results (n = 10) in the PCR methods, we were able to improve their quality for later sequencing. All samples with weak band and 7 out of 10 negative samples, showed strong positive results after cloning. So nested-rpoB PCR cloning revealed positivity in 67 out of 70 confirmed samples (95.7%). The sensitivity of these combination methods was calculated as 95.7% in comparison with histopathology examination. The CI for sensitivity of the PCR methods were calculated as 11.39-31.27% for rpoB-PCR, 36.44-60.83% for IS6110- PCR, 75.29-92.93% for nested-rpoB PCR, and 87.98-99.11% for nested-rpoB PCR cloning. The 10 true EPTB negative samples by histopathology, were negative by all tested methods including cloning and were used to calculate the specificity of the applied methods. The CI for 100% specificity of each PCR method were calculated as 69.15-100%. Our results indicated that nested-rpoB PCR combined with TA cloning and sequencing is a preferred method for the detection of MTB DNA in EPTB samples with high sensitivity and specificity which confirm the histopathology results.
Del Negro, G M; Garcia, N M; Rodrigues, E G; Cano, M I; de Aguiar, M S; Lírio, V de S; Lacaz, C da S
1991-01-01
This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e., a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO. The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.
Tantisira, J G; Kowalski, R P; Gordon, Y J
1995-07-01
The Kodak Surecell Chlamydia test, a rapid enzyme immunoassay, has been reported to be highly sensitive (93%) and specific (96%) for detecting chlamydial lipopolysaccharide antigen in conjunctival specimens from infants, but has not been evaluated previously in adult conjunctival specimens. This study was designed to determine the efficacy of the Kodak Surecell Chlamydia test for the laboratory diagnosis of adult inclusion conjunctivitis. Twenty Chlamydia culture-positive conjunctival specimens from adults (true-positives) and 20 true-negative specimens were tested with the Kodak Surecell Chlamydia test. The Kodak Surecell Chlamydia test was 40% (8/20) sensitive, 100% (20/20) specific, and 70% (28/40) efficient. This study indicates that the Kodak Surecell Chlamydia test, though highly specific, is less sensitive in its ability to diagnose chlamydial conjunctivitis in adults than has been reported previously in infants.
Robinson, Tyler J W; Liu, Jeff C; Vizeacoumar, Frederick; Sun, Thomas; Maclean, Neil; Egan, Sean E; Schimmer, Aaron D; Datti, Alessandro; Zacksenhaus, Eldad
2013-01-01
Triple negative breast cancer (TNBC) includes basal-like and claudin-low subtypes for which only chemotherapy and radiation therapy are currently available. The retinoblastoma (RB1) tumor suppressor is frequently lost in human TNBC. Knockdown of RB1 in luminal BC cells was shown to affect response to endocrine, radiation and several antineoplastic drugs. However, the effect of RB1 status on radiation and chemo-sensitivity in TNBC cells and whether RB1 status affects response to divergent or specific treatment are unknown. Using multiple basal-like and claudin-low cell lines, we hereby demonstrate that RB-negative TNBC cell lines are highly sensitive to gamma-irradiation, and moderately more sensitive to doxorubicin and methotrexate compared to RB-positive TNBC cell lines. In contrast, RB1 status did not affect sensitivity of TNBC cells to multiple other drugs including cisplatin (CDDP), 5-fluorouracil, idarubicin, epirubicin, PRIMA-1(met), fludarabine and PD-0332991, some of which are used to treat TNBC patients. Moreover, a non-biased screen of ∼3400 compounds, including FDA-approved drugs, revealed similar sensitivity of RB-proficient and -deficient TNBC cells. Finally, ESA(+)/CD24(-/low)/CD44(+) cancer stem cells from RB-negative TNBC lines were consistently more sensitive to gamma-irradiation than RB-positive lines, whereas the effect of chemotherapy on the cancer stem cell fraction varied irrespective of RB1 expression. Our results suggest that patients carrying RB-deficient TNBCs would benefit from gamma-irradiation as well as doxorubicin and methotrexate therapy, but not necessarily from many other anti-neoplastic drugs.
Lee, DoKyung; Kim, Eun Jin; Kilgore, Paul E; Kim, Soon Ae; Takahashi, Hideyuki; Ohnishi, Makoto; Anh, Dang Duc; Dong, Bai Qing; Kim, Jung Soo; Tomono, Jun; Miyamoto, Shigehiko; Notomi, Tsugunori; Kim, Dong Wook; Seki, Mitsuko
2015-01-01
Neisseria meningitidis (Nm) is a leading causative agent of bacterial meningitis in humans. Traditionally, meningococcal meningitis has been diagnosed by bacterial culture. However, isolation of bacteria from patients' cerebrospinal fluid (CSF) is time consuming and sometimes yields negative results. Recently, polymerase chain reaction (PCR)-based diagnostic methods of detecting Nm have been considered the gold standard because of their superior sensitivity and specificity compared with culture. In this study, we developed a loop-mediated isothermal amplification (LAMP) method and evaluated its ability to detect Nm in cerebrospinal fluid (CSF). We developed a meningococcal LAMP assay (Nm LAMP) that targets the ctrA gene. The primer specificity was validated using 16 strains of N. meningitidis (serogroup A, B, C, D, 29-E, W-135, X, Y, and Z) and 19 non-N. meningitidis species. Within 60 min, the Nm LAMP detected down to ten copies per reaction with sensitivity 1000-fold more than that of conventional PCR. The LAMP assays were evaluated using a set of 1574 randomly selected CSF specimens from children with suspected meningitis collected between 1998 and 2002 in Vietnam, China, and Korea. The LAMP method was shown to be more sensitive than PCR methods for CSF samples (31 CSF samples were positive by LAMP vs. 25 by PCR). The detection rate of the LAMP method was substantially higher than that of the PCR method. In a comparative analysis of the PCR and LAMP assays, the clinical sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP assay were 100%, 99.6%, 80.6%, and 100%, respectively. Compared to PCR, LAMP detected Nm with higher analytical and clinical sensitivity. This sensitive and specific LAMP method offers significant advantages for screening patients on a population basis and for diagnosis in clinical settings.
Touré, Abdoulaye; Butel, Christelle; Keita, Alpha Kabinet; Binetruy, Florian; Sow, Mamadou S.; Foulongne, Vincent; Delaporte, Eric; Peeters, Martine
2016-01-01
ABSTRACT The recent Zaire Ebola virus (EBOV) outbreak in West Africa illustrates clearly the need for additional studies with humans and animals to elucidate the ecology of Ebola viruses (EBVs). In this study, we developed a serological assay based on the Luminex technology. Nine recombinant proteins representing different viral regions (nucleoprotein [NP], 40-kDa viral protein [VP40], and glycoprotein [GP]) from four of the five EBV lineages were used. Samples from 94 survivors of the EBOV outbreak in Guinea and negative samples from 108 patients in France were used to calculate test performance for EBOV detection and cross-reaction with other Ebola virus lineages. For EBOV antibody detection, sensitivities of 95.7%, 96.8%, and 92.5% and specificities of 94.4%, 95.4%, and 96.3% for NP, GP, and VP40, respectively, were observed. All EBOV-negative samples that presented a reaction, except for one, interacted with a single antigen, whereas almost all samples from EBOV survivors were simultaneously reactive with NP and GP (90/94) or with NP, GP, and VP40 (87/94). Considering as positive for past EBOV infection only samples that reacted with EBOV NP and GP, sensitivity was 95.7% and specificity increased to 99.1%. Comparing results with commercial EBOV NP and GP enzyme-linked immunosorbent assays (ELISAs; Alpha Diagnostic, San Antonio, TX), lower sensitivity (92.5%) and high specificity (100%) were observed with the same positivity criteria. Samples from EBOV survivors cross-reacted with GP from Sudan Ebola virus (GP-SUDV) (81.9%), GP from Bundibugyo Ebola virus (GP-BDBV) (51.1%), GP from Reston Ebola virus (GP-RESTV) (9.6%), VP40-SUDV (76.6%), and VP40-BDBV (38.3%). Overall, we developed a sensitive and specific high-throughput serological assay, and defined an algorithm, for epidemiological surveys with humans. PMID:27795350
Ayouba, Ahidjo; Touré, Abdoulaye; Butel, Christelle; Keita, Alpha Kabinet; Binetruy, Florian; Sow, Mamadou S; Foulongne, Vincent; Delaporte, Eric; Peeters, Martine
2017-01-01
The recent Zaire Ebola virus (EBOV) outbreak in West Africa illustrates clearly the need for additional studies with humans and animals to elucidate the ecology of Ebola viruses (EBVs). In this study, we developed a serological assay based on the Luminex technology. Nine recombinant proteins representing different viral regions (nucleoprotein [NP], 40-kDa viral protein [VP40], and glycoprotein [GP]) from four of the five EBV lineages were used. Samples from 94 survivors of the EBOV outbreak in Guinea and negative samples from 108 patients in France were used to calculate test performance for EBOV detection and cross-reaction with other Ebola virus lineages. For EBOV antibody detection, sensitivities of 95.7%, 96.8%, and 92.5% and specificities of 94.4%, 95.4%, and 96.3% for NP, GP, and VP40, respectively, were observed. All EBOV-negative samples that presented a reaction, except for one, interacted with a single antigen, whereas almost all samples from EBOV survivors were simultaneously reactive with NP and GP (90/94) or with NP, GP, and VP40 (87/94). Considering as positive for past EBOV infection only samples that reacted with EBOV NP and GP, sensitivity was 95.7% and specificity increased to 99.1%. Comparing results with commercial EBOV NP and GP enzyme-linked immunosorbent assays (ELISAs; Alpha Diagnostic, San Antonio, TX), lower sensitivity (92.5%) and high specificity (100%) were observed with the same positivity criteria. Samples from EBOV survivors cross-reacted with GP from Sudan Ebola virus (GP-SUDV) (81.9%), GP from Bundibugyo Ebola virus (GP-BDBV) (51.1%), GP from Reston Ebola virus (GP-RESTV) (9.6%), VP40-SUDV (76.6%), and VP40-BDBV (38.3%). Overall, we developed a sensitive and specific high-throughput serological assay, and defined an algorithm, for epidemiological surveys with humans. Copyright © 2016 American Society for Microbiology.
Garcia, L S; Shimizu, R Y
1997-01-01
It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of interpretation of results (color, intensity of fluorescence), equipment, available personnel, and number of tests ordered are also important considerations prior to kit selection. PMID:9163474
Quality control in molecular immunohistochemistry
2008-01-01
Immunoperoxidase histochemistry is a widespread method of assessing expression of biomolecules in tissue samples. Accurate assessment of the expression levels of genes is critical for the management of disease, particularly as therapy targeted to specific molecules becomes more widespread. Determining the quality of preservation of macromolecules in tissue is important to avoid false negative and false positive results. In this review we discuss (1) issues of sensitivity (false negativity) and specificity (false positivity) of immunohistochemical stains, (2) approaches to better understanding differences in immunostains done by different laboratories (including the recently proposed MISFISHIE specification for tissue localization studies), and (3) approaches to assessing the quality of preservation of macromolecules in tissue, particularly in small biopsy samples. PMID:18648842
Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya
2015-01-01
The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.
Alzeidan, Rasmieh Ayed; Mandil, Ahmed Amin; Fayed, Amel Ahmed; Wahabi, Hayfaa Abdulmajeed
2013-10-01
Exposure to environmental tobacco smoke (ETS) has harmful effects on the pregnancy outcomes similar to those observed in actively smoking pregnant women. The aim of this study was to estimate the sensitivity and specificity of the breath carbon monoxide (BCO) analysis in the assessment of smoking status among Saudi pregnant women, including ETS exposure compared to self-reported tobacco smoke exposure. A cross-sectional design was used during January 2012, 560 pregnant women, irrespective of their gestational age, agreed to undergo BCO testing and completed the data collection sheet for the study. Sensitivity, specificity, positive and negative predictive values were calculated to compare the BCO test with self-reported exposure to ETS. Of the study population 151 (27%) women self-reported ETS exposure during the index pregnancy, 409 (73%) self-reported non-exposure. Sensitivity of the test was 32.5% (95% CI; 25.2-40.3%), the Specificity was much higher at 69.2% (95% CI; 64.4-73.5%), the positive predictive value was 28% (95% CI, 21.9-35.1%), and the negative predictive value was 73.5% (95% CI; 68.9-77.7%). The BCO test is an ineffective tool to detect the level of ETS exposure among Saudi pregnant women.
Le Strat, Yann
2017-01-01
The objective of this paper is to evaluate a panel of statistical algorithms for temporal outbreak detection. Based on a large dataset of simulated weekly surveillance time series, we performed a systematic assessment of 21 statistical algorithms, 19 implemented in the R package surveillance and two other methods. We estimated false positive rate (FPR), probability of detection (POD), probability of detection during the first week, sensitivity, specificity, negative and positive predictive values and F1-measure for each detection method. Then, to identify the factors associated with these performance measures, we ran multivariate Poisson regression models adjusted for the characteristics of the simulated time series (trend, seasonality, dispersion, outbreak sizes, etc.). The FPR ranged from 0.7% to 59.9% and the POD from 43.3% to 88.7%. Some methods had a very high specificity, up to 99.4%, but a low sensitivity. Methods with a high sensitivity (up to 79.5%) had a low specificity. All methods had a high negative predictive value, over 94%, while positive predictive values ranged from 6.5% to 68.4%. Multivariate Poisson regression models showed that performance measures were strongly influenced by the characteristics of time series. Past or current outbreak size and duration strongly influenced detection performances. PMID:28715489
Li, Zhanzhan; Zhou, Qin; Li, Yanyan; Yan, Shipeng; Fu, Jun; Huang, Xinqiong; Shen, Liangfang
2017-02-28
We conducted a meta-analysis to evaluate the diagnostic values of mean cerebral blood volume for recurrent and radiation injury in glioma patients. We performed systematic electronic searches for eligible study up to August 8, 2016. Bivariate mixed effects models were used to estimate the combined sensitivity, specificity, positive likelihood ratios, negative likelihood ratios, diagnostic odds ratios and their 95% confidence intervals (CIs). Fifteen studies with a total number of 576 participants were enrolled. The pooled sensitivity and specificity of diagnostic were 0.88 (95%CI: 0.82-0.92) and 0.85 (95%CI: 0.68-0.93). The pooled positive likelihood ratio is 5.73 (95%CI: 2.56-12.81), negative likelihood ratio is 0.15 (95%CI: 0.10-0.22), and the diagnostic odds ratio is 39.34 (95%CI:13.96-110.84). The summary receiver operator characteristic is 0.91 (95%CI: 0.88-0.93). However, the Deek's plot suggested publication bias may exist (t=2.30, P=0.039). Mean cerebral blood volume measurement methods seems to be very sensitive and highly specific to differentiate recurrent and radiation injury in glioma patients. The results should be interpreted with caution because of the potential bias.
Queiroz Filho, José; de Oliveira Crispim Freitas, Janaina Cristiana; Caldas Pessoa, Daliana; Eleutério Júnior, José; Giraldo, Paulo César; Gonçalves, Ana Katherine
2017-01-01
The aim of this study was to evaluate the 100% rapid review (100%-RR) as an effective tool for internal quality control (IQC) in gynecological cytopathology services. A total of 8,677 swabs were analyzed; the negative results were submitted to 100%-RR. Divergent cases were discussed in a consensus meeting to reach a conclusion on the final diagnosis. The data were entered into SAS statistical software, and the agreement of the 100%-RR results with the final diagnosis was tested with the weighted kappa statistic. Of the 8,155 smears characterized as negative, 255 (3.13%) were abnormal smears, and 552 (6.77%) unsatisfactory smears were deemed negative. Regarding the results on the 8,155 smears subjected to 100%-RR when compared with the final diagnosis, there was agreement in 7,063 (86.60%) of them, and there were 1,092 (13.40%) discordant results (65.6%, unsatisfactory; 5.47%, atypical squamous cells of undetermined significance [ASC-US]). The κ index had an agreement of 0.867, with κ = 0.734 (p < 0.0001). Compared with the final diagnosis, the sensitivity of 100%-RR was 99.91% and its specificity was 99.4% for severe abnormalities. The sensitivity for high-grade squamous intraepithelial lesions was 88.2%, with a specificity of 100.00%. For abnormalities considered borderline, such as ASC-US, the sensitivity was 94.50% and the specificity was 99.5%. The 100%-RR was considered efficient when used as an IQC method. © 2017 S. Karger AG, Basel.
Döner, Rana Kaya; Sager, Sait; Görtan, Fatma Arzu; Topuz, Özge Vural; Akyel, Reşit; Vatankulu, Betül; Baran, Ahmet; Teksoz, Serkan; Sönmezoglu, Kerim
2016-01-01
This retrospective study aims to assess the cut-off value of thyroglobulin (Tg) levels in nux or metastatic well-differentiated thyroid cancers (DTCs) with normal anti-Tg levels using with fluorodeoxyglucose/positron emission tomography/computed tomography (FDG PET/CT). We reviewed FDG PET/CT images of 104 patients with well DTC (28 men, 76 women) whose: Iodine-131 (131 I) whole-body scanning was negative but had elevated Tg with normal anti-Tg levels. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of florine-18-FDG PET/CT findings were found to be 95.92%, 87.27%, 87.04%, 96.00%, and 91.35%, respectively. The best Tg cut-off value was found to be 10.4 ng/ml. In the Tg level <10.4 ng/ml group, the sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT were found to be 94.1%, 91.30%, 88.8%, 95.4%, and 92.5%, respectively. In the other group, which Tg level ≥10.4 ng/ml, sensitivity, specificity, PPV, NPV, and accuracy of FDG PET/CT exams were found to be 96.8%, 84.3%, 86.1%, 96.4%, and 90.6%, respectively. FDG PET/CT imaging is a valuable imaging method in the evaluation of patients with elevated serum Tg levels and normal anti-Tg levels. Furthermore, it has potential utility in the dedifferentiation of active foci that are present, and in assessing optimal decision making during follow-up.
Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon
2017-01-01
The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.
Hwang, Hamish; Marsh, Ian; Doyle, Jason
2014-01-01
Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607
Evaluation of brush cytology and DNA image cytometry for the detection of cancer of the oral cavity.
Kaur, Manveen; Handa, Uma; Mohan, Harsh; Dass, Arjun
2016-03-01
Cancer of the oral cavity is the sixth most common malignancy reported worldwide. This study was undertaken to evaluate the efficacy of brush cytology and the adjunctive role of DNA image cytometry (ICM) in the diagnosis of oral cancer. Oral brush smears and biopsy were obtained from 100 consecutive patients presenting with suspicious oral lesions. DNA-ICM was performed on 96 cytology smears which had adequate cellularity. On cytology, 54 cases were benign, 36 were malignant, 6 were suspicious for malignancy, and 4 were inadequate due to scanty cellularity. On histopathologic examination, 49 cases were diagnosed as squamous cell carcinoma and 51 cases as benign. The sensitivity of brush cytology for the detection of cancer was 83.3% and the specificity was 95.8%. The positive and negative predictive values were 95.2% and 85.2%, respectively, with a diagnostic accuracy of 86%. Out of 96 cases analyzed by image analysis to assess DNA ploidy, 33 cases were aneuploid and 63 were diploid. The sensitivity, specificity, positive predictive value, and negative predictive value of DNA-ICM were 68.7%, 100%, 100%, and 76.1%, respectively, giving a diagnostic accuracy of 81%. The combination of cytology and DNA cytometry increased the sensitivity to 92% and specificity to 100%. The study demonstrates the usefulness of DNA-ICM as an adjunct to brush cytology to diagnose oral cancer. It reduces the false negative cases on cytology and also adds to objectivity in cytologically doubtful cases. © 2016 Wiley Periodicals, Inc.
Is screening with digital imaging using one retinal view adequate?
Herbert, H M; Jordan, K; Flanagan, D W
2003-05-01
To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.
Sert Kuniyoshi, Fatima H.; Zellmer, Mark R.; Calvin, Andrew D.; Lopez-Jimenez, Francisco; Albuquerque, Felipe N.; van der Walt, Christelle; Trombetta, Ivani C; Caples, Sean M.; Shamsuzzaman, Abu S.; Bukartyk, Jan; Konecny, Tomas; Gami, Apoor S.; Kara, Tomas
2011-01-01
Background: The Berlin Questionnaire (BQ) has been used to identify patients at high risk for sleep-disordered breathing (SDB) in a variety of populations. However, there are no data regarding the validity of the BQ in detecting the presence of SDB in patients after myocardial infarction (MI). The aim of this study was to determine the performance of the BQ in patients after MI. Methods: We conducted a cross-sectional study of 99 patients who had an MI 1 to 3 months previously. The BQ was administered, scored using the published methods, and followed by completed overnight polysomnography as the “gold standard.” SDB was defined as an apnea-hypopnea index of ≥ 5 events/h. The sensitivity, specificity, and positive and negative predictive values of the BQ were calculated. Results: Of the 99 patients, the BQ identified 64 (65%) as being at high-risk for having SDB. Overnight polysomnography showed that 73 (73%) had SDB. The BQ sensitivity and specificity was 0.68 and 0.34, respectively, with a positive predictive value of 0.68 and a negative predictive value of 0.50. Positive and negative likelihood ratios were 1.27 and 0.68, respectively, and the BQ overall diagnostic accuracy was 63%. Using different apnea-hypopnea index cutoff values did not meaningfully alter these results. Conclusion: The BQ performed with modest sensitivity, but the specificity was poor, suggesting that the BQ is not ideal in identifying SDB in patients with a recent MI. PMID:21596794
Papadia, Andrea; Gasparri, Maria Luisa; Genoud, Sophie; Bernd, Klaeser; Mueller, Michael D
2017-11-01
The aim of the study was to evaluate the use of PET/CT and/or SLN mapping alone or in combination in cervical cancer patients. Data on stage IA1-IIA cervical cancer patients undergoing PET/CT and SLN mapping were retrospectively collected. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of PET/CT and SLN mapping, alone or in combination, in identifying cervical cancer patients with lymph node metastases were calculated. Sixty patients met the inclusion criteria. PET/CT showed a sensitivity of 68%, a specificity of 84%, a PPV of 61% and a NPV of 88% in detecting lymph nodal metastases. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 97%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 86%, a PPV of 72% and a NPV of 100%. For patients with tumors of >2 cm in diameter, the PET/CT showed a sensitivity of 68%, a specificity of 72%, a PPV of 61% and a NPV of 86%. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 95%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 76%, a PPV of 72% and a NPV of 100%. PET/CT represents a "safety net" that helps the surgeon in identifying metastatic lymph nodes, especially in patients with larger tumors.
Martinez, Fernando; Chandler, Laura J.; Reisner, Barbara S.; Woods, Gail L.
2001-01-01
The performance of Vitek cards GPS105 with software version VTK-R07.01 for detection of oxacillin resistance in coagulase-negative staphylococci (CoNS) was compared to disk diffusion and PCR detection for mecA. The sensitivity and specificity of the Vitek GPS105 method were 97.6 and 85.5%, respectively. PMID:11574604
Pan, Liping; Jia, Hongyan; Liu, Fei; Gao, Mengqiu; Sun, Huishan; Du, Boping; Sun, Qi; Xing, Aiying; Wei, Rongrong; Zhang, Zongde
2015-12-01
To evaluate the value of T-SPOT.TB assay in the diagnosis of pulmonary tuberculosis within different age groups. We analyzed 1 518 suspected pulmonary tuberculosis (PTB) patients who were admitted to the Beijing Chest Hospital from November 2012 to February 2014 and had valid T-SPOT.TB tests before anti-tuberculosis therapy. The 599 microbiologically and/or histopathologically-confirmed PTB patients (16-89 years old, 388 males and 211 females) and 235 non-TB patients (14-85 years old, 144 males and 91 females) were enrolled for the analysis of diagnostic performance of T-SPOT.TB, while patients with uncertain diagnosis or diagnosis based on clinical impression (n=684) were excluded from the analysis. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB were analyzed according to the final diagnosis. Furthermore, the diagnostic performance of T-SPOT.TB assay in the younger patients (14-59 years old) and elderly patients (60-89 years old) were also analyzed respectively. Categorical variables were compared by Pearson's Chi-square test, while continuous variables were compared by the Mann-Whitney U-test. The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the T-SPOT.TB in diagnosis of PTB were 90.1% (540/599), 65.5% (154/235), 86.9% (540/621), 72.3% (154/213), 2.61, and 0.15, respectively. The sensitivity and specificity of T-SPOT.TB assay were 92.6% (375/405) and 75.6% (99/131), respectively in the younger patients, and 85.0% (165/194), 52.9% (55/104) respectively in the elderly patients. The sensitivity and specificity of T-SPOT.TB assay in the younger patients were significantly higher than those in the elderly patients (P<0.01), and the spot forming cells in the younger PTB patients were significantly higher than in the elderly PTB patients [300 (126, 666)/10(6) PBMCs vs. 258 (79, 621)/10(6) PBMCs, P=0.037]. T-SPOT.TB is a promising test in the diagnosis of younger patients (14-59 years old) with suspected PTB, but the diagnostic performance in elderly patients (60-89 years old) is relatively reduced.
Raoofi, Z; Barchinegad, M; Haghighi, L
2013-01-01
To evaluate the value of Chlamydia trachomatis antibody testing in prediction of at least one normal tube in infertile women. Eighty infertile women without any history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis were recruited in this cross-sectional study from 2009 to 2010. The patients underwent hysterosalpingography, laparoscopy, and anti Chlamydia trachomatis IgG antibody (CAT) testing. We compared laparoscopy findings and CAT regarding sensitivity, specificity, accuracy, and predicting value of tubal conditions. The CAT was positive in 50 patients (62.5%) and laparoscopy was positive in 32 patients (40%). The CAT was significantly higher in women with tubal disease (1.88 +/- 0.34) versus in women with normal tubes (1.21 +/- 0.28) (p = 0.003). Five out of 30 sero-negative women had unilateral tubal abnormality and none of them had bilateral tubal obstruction or severe pelvic adhesion. The sensitivity, specificity, positive and negative predictive value, and accuracy of the CAT in prediction of one normal tube were 100%, 42.25%, 18%, 100%, and 48.75%, respectively. The negative predictive value of CAT to predict at least one normal tube in infertile women without history of abdominal or pelvic surgery, pelvic inflammatory disease, and endometriosis was 100%.
Lansu, Tessa A M; van Noorden, Tirza H J; Deutz, Marike H F
2017-02-01
This study examined whether victimization is associated with negatively distorted social cognition (bias), or with a specific increased sensitivity to social negative cues, by assessing the perception of social exclusion and the consequences for psychological well-being (moods and fundamental needs). Both self-reported and peer-reported victimization of 564 participants (M age =9.9years, SD=1.04; 49.1% girls) were measured, and social exclusion was manipulated through inclusion versus exclusion in a virtual ball-tossing game (Cyberball). Children's perceptions and psychological well-being were in general more negative after exclusion than after inclusion. Moreover, self-reported-but not peer-reported-victimization was associated with the perception of being excluded more and receiving the ball less, as well as more negative moods and less fulfillment of fundamental needs, regardless of being excluded or included during the Cyberball game. In contrast, peer-reported victimization was associated with more negative mood and lower need fulfillment in the exclusion condition only. Together, these results suggest that children who themselves indicate being victimized have negatively distorted social cognition, whereas children who are being victimized according to their peers experience increased sensitivity to negative social situations. The results stress the importance of distinguishing between self-reported and peer-reported victimization and have implications for interventions aimed at victimized children's social cognition. Copyright © 2016 Elsevier Inc. All rights reserved.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
Maekura, Ryoji; Okuda, Yoshinari; Nakagawa, Masaru; Hiraga, Touru; Yokota, Souichirou; Ito, Masami; Yano, Ikuya; Kohno, Hiroaki; Wada, Masako; Abe, Chiyoji; Toyoda, Takeo; Kishimoto, Toshio; Ogura, Takeshi
2001-01-01
Previously we reported the development of a highly sensitive enzyme-linked immunosorbent assay specific for anti-tuberculous glycolipid (anti-TBGL) for the rapid serodiagnosis of tuberculosis. In this study, the usefulness of an anti-TBGL antibody assay kit for rapid serodiagnosis was evaluated in a controlled multicenter study. Antibody titers in sera from 318 patients with active pulmonary tuberculosis (216 positive for Mycobacterium tuberculosis in smear and/or culture tests and 102 smear and culture negative and clinically diagnosed), 58 patients with old tuberculosis, 177 patients with other respiratory diseases, 156 patients with nonrespiratory diseases, and 454 healthy subjects were examined. Sera from 256 younger healthy subjects from among the 454 healthy subjects were examined as a control. When the cutoff point of anti-TBGL antibody titer was determined as 2.0 U/ml, the sensitivity for active tuberculosis patients was 81.1% and the specificity was 95.7%. Sensitivity in patients with smear-negative and culture-negative active pulmonary tuberculosis was 73.5%. Even in patients with noncavitary minimally advanced lesions, the positivity rate (60.0%) and the antibody titer (4.6 ± 9.4 U/ml) were significantly higher than those in the healthy group. These results indicate that this assay using anti-TBGL antibody is useful for the rapid serodiagnosis of active pulmonary tuberculosis. PMID:11574580
Kenttä, Tuomas; Porthan, Kimmo; Tikkanen, Jani T; Väänänen, Heikki; Oikarinen, Lasse; Viitasalo, Matti; Karanko, Hannu; Laaksonen, Maarit; Huikuri, Heikki V
2015-07-01
Early repolarization (ER) is defined as an elevation of the QRS-ST junction in at least two inferior or lateral leads of the standard 12-lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER. A total of 6,047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER-positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference. Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5,864 ER-negative recordings, the algorithm classified 5,281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases. As the automatic algorithm has high sensitivity, it could be used as a prescreening tool for ER; only the electrocardiograms graded positive by the algorithm would be reviewed manually. This would reduce the need for manual labor by 90%. © 2014 Wiley Periodicals, Inc.
Küçük, Oznur; Biçer, Suat; Giray, Tuba; Cöl, Defne; Erdağ, Gülay Ciler; Gürol, Yeşim; Kaspar, Ciğdem E; Vitrinel, Ayça
2014-02-01
To evaluate the utility of rapid antigen detection testing (RADT) for the diagnosis of group A beta-hemolytic streptococcal tonsillopharyngitis in children, and to detect the sensitivity and specificity of rapid antigen detection of group A beta-hemolytic streptococci from throat specimen compared with throat culture. Rapid antigen detection and throat culture results for group A beta-hemolytic streptococci from outpatients attending university hospital between 1st January 2011 and 31st of December 2011 were evaluated retrospectively. The antigen test negative-throat culture positive patients were investigated for streptococcal carriage. For this purpose, the throat culture results taken from these patients were reviewed after treatment. Eight hundred and ninetytwo children were included in the studywith a mean age of 5.34 y. There were 639 and 253 children in two groups with age of 0-6 and 7-17 y, RADT sensitivity and specificity were found to be 59.5 % and 97.2 %, respectively. The positive predictive value was 87.1 %, whereas negative predictive value was 88.4 %. After treatment of 74 patients with throat culture positive and antigen test negative. Group A beta-hemolytic streptococci were isolated in 12 of them (16.2 %) and accepted as a carrier. The low sensitivity of the RADT may be related to streptococcal carriage in some patients. The throat culture should be repeated after treatment to detect streptococcal carriage.
[An oral sensitization food allergy model in Brown-Norway rats].
Huang, Juan; Zhong, Yan; Cai, Wei; Zhang, Hongbo
2009-01-01
To develop an oral-sensitized animal model of food allergy using Brown-Norway (BN) rats and evaluate the sensitivity of ELISA and passive cutaneous anaphylaxis (PCA) in detecting ovalbumin-specific IgE antibody (OVA-IgE) level in sensitized animals. Sixteen 3-week old female BN rats were randomly divided into 3 groups: negative control group orally gavaged with saline, positive control group sensitized by intraperitoneal injection of 0. lmg/d OVA, and, study group sensitized by daily gavage of 1 mg/d ovalbumin (OVA). OVA-IgE was analyzed by ELISA and PCA method at week 4, 5, 6, 7, 8 and 9. At week 13, OVA-IgE level was analyzed after orally challenged by 1.0 ml of 100 mg/ml OVA. The ELISA result showed that the OVA-IgE level in study group was significantly increased at week 6, 7 and week 8 compared with negative control group (P < 0.05), and the highest level was found at week 6. There was no significant difference for the level of OVA-IgE between study group and positive control group. The sensitization rate in study group was 60%, 80% and 80% at week 6, 7 and 8 respectively, which was similar to positive control group. All PCA results in study group were negative, while in positive control group it was positive. Oral sensitization could be used as a suitable method to establish an animal model of food allergy, which is more comparable with the natural sensitization process in food allergy patients. ELISA method is more sensitive in detecting OVA-IgE level in oral sensitized animal model than PCA method.
Yan, Liping; Xiao, Heping; Zhang, Qing
2016-01-01
Technological advances in nucleic acid amplification have led to breakthroughs in the early detection of PTB compared to traditional sputum smear tests. The sensitivity and specificity of loop-mediated isothermal amplification (LAMP), simultaneous amplification testing (SAT), and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis were evaluated. A critical review of previous studies of LAMP, SAT, and Xpert MTB/RIF for the diagnosis of pulmonary tuberculosis that used laboratory culturing as the reference method was carried out together with a meta-analysis. In 25 previous studies, the pooled sensitivity and specificity of the diagnosis of tuberculosis were 93% and 94% for LAMP, 96% and 88% for SAT, and 89% and 98% for Xpert MTB/RIF. The I(2) values for the pooled data were >80%, indicating significant heterogeneity. In the smear-positive subgroup analysis of LAMP, the sensitivity increased from 93% to 98% (I(2) = 2.6%), and specificity was 68% (I(2) = 38.4%). In the HIV-infected subgroup analysis of Xpert MTB/RIF, the pooled sensitivity and specificity were 79% (I(2) = 72.9%) and 99% (I(2) = 64.4%). In the HIV-negative subgroup analysis for Xpert MTB/RIF, the pooled sensitivity and specificity were 72% (I(2) = 49.6%) and 99% (I(2) = 64.5%). LAMP, SAT and Xpert MTB/RIF had comparably high levels of sensitivity and specificity for the diagnosis of tuberculosis. The diagnostic sensitivity and specificity of three methods were similar, with LAMP being highly sensitive for the diagnosis of smear-positive PTB. The cost effectiveness of LAMP and SAT make them particularly suitable tests for diagnosing PTB in developing countries. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chin-Hong, Peter V; Berry, J Michael; Cheng, Su-Chun; Catania, Joseph A; Da Costa, Maria; Darragh, Teresa M; Fishman, Fred; Jay, Naomi; Pollack, Lance M; Palefsky, Joel M
2008-09-02
Human papillomavirus (HPV)-associated anal cancer is increasing in prevalence and is more common among men who have sex with men and HIV-positive individuals than cervical cancer is among women in the United States. Cytology screening can detect the anal cancer precursor, anal intraepithelial neoplasia (AIN). Little is known about self-collected samples for AIN screening, and few community-based AIN estimates exist. To compare the sensitivity of self-collected versus clinician-collected anal cytology specimens to detect biopsy-confirmed AIN and the prevalence estimate of AIN in a community sample. Cross-sectional study. Participants were mailed anal cytology self-collection kits with instructions. Clinicians repeated anal cytology and performed high-resolution anoscopy with biopsies as the diagnostic reference standard. San Francisco, California. Community-based sample of men who have sex with men. Prevalence of anal HPV and AIN. Sensitivity and specificity of self-collected and clinician-collected anal cytology specimens to diagnose AIN were calculated. Biopsy-proven AIN was diagnosed in 57% of HIV-positive and 35% of HIV-negative participants (P = 0.04), and 80% provided adequate self-collected specimens for interpretation. The sensitivity of cytology to detect AIN in HIV-positive men was 75% (95% CI, 51% to 93%) when self-collected and 90% (CI, 68% to 99%) when clinician-collected; respective values in HIV-negative men were 48% (CI, 26% to 70%) and 62% (CI, 38% to 82%). The specificity of cytology to detect AIN in HIV-positive men was 50% (CI, 22% to 78%) when self-collected and 64% (CI, 36% to 86%) when clinician-collected; respective values in HIV-negative men were 86% (CI, 71% to 94%) and 85% (CI, 72% to 93%). The study sample was from a narrowly defined geographical area. Participants self-reported HIV status. In a community-based sample, a high proportion of HIV-positive and HIV-negative men who have sex with men have AIN. The sensitivity of cytology to detect AIN is higher for clinician-collected versus self-collected specimens and for HIV-positive versus HIV-negative men. The specificity of cytology to detect AIN is higher in HIV-negative versus HIV-positive men. However, the probability of AIN in a patient with a negative cytology result may not be low enough (23% for HIV-negative men and 45% for HIV-positive men with a patient-collected specimen) for clinicians to be comfortable recommending no anoscopy for those with a negative cytology result if done as a one-time test. These data raise the question of whether the optimal population screening strategy is cytology screening with anoscopy only for those who test positive or whether anoscopy should be recommended for everyone in these risk groups. Given limited resources and the limited number of clinicians trained in anoscopy, cytology screening may be the best current approach to identifying disease in the at-risk population.
Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio
2018-01-31
To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.
Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R
1999-10-01
Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and =0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.
1999-01-01
Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results. PMID:10488183
Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.
Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K
2017-08-01
The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.
Piera, Kim A; Aziz, Ammar; William, Timothy; Bell, David; González, Iveth J; Barber, Bridget E; Anstey, Nicholas M; Grigg, Matthew J
2017-01-13
Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection. Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs. The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL. The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.
Silva, William P P; Stramandinoli-Zanicotti, Roberta T; Schussel, Juliana L; Ramos, Gyl H A; Ioshi, Sergio O; Sassi, Laurindo M
2016-11-01
Objective: This article concerns evaluation of the sensitivity, specificity and accuracy of FNAB for pre-surgical diagnosis of benign and malignant lesions of major and minor salivary glands of patients treated in the Department of Head and Neck Surgery of Erasto Gartner Hospital. Methods: This retrospective study analyzed medical records from January 2006 to December 2011 from patients with salivary gland lesions who underwent preoperative FNAB and, after surgical excision of the lesion, histopathological examination. Results: The study had a cohort of 130 cases, but 34 cases (26.2%) were considered unsatisfactory regarding cytology analyses. Based on the data, sensitivity was 66.7% (6/9), specificity was 81.6% (71/87), accuracy was 80.2% (77/96), the positive predictive value was 66,7% (6/9) and the negative predictive value was 81.6% (71/87). Conclusion: Despite the high rate of inadequate samples obtained in the FNAB in this study the technique offers high specificity, accuracy and acceptable sensitivity. Creative Commons Attribution License
Jamshidi Makiani, Mahin; Davoodian, Parivash; Baghershiroodi, Mahnaz; Nejatizadeh, Abdol Azim; Fakkhar, Farideh; Zangeneh, Mehrangiz; Jahangiri, Nadia
2016-08-01
While tuberculosis (TB) can be diagnosed by microscopy and culture, the sensitivity of Ziehl-Neelsen staining is variable and culture results require 4 - 8 weeks to be determined. Polymerase chain reaction (PCR) and its modifications, including nested PCR, might be promising methods for the rapid diagnosis of TB. This study aimed to evaluate the performance of nested PCR on urine samples of human immunodeficiency virus (HIV)-positive and -negative patients with different manifestations of clinical TB. In a prospective study, three early-morning urine samples from 100 patients with pulmonary TB (PTB) or extrapulmonary TB (EPTB) were evaluated using a molecular target with insertion element IS6110, specific to the Mycobacterium tuberculosis genome, and nested PCR was performed. The results were analyzed with SPSS version 22. A total of 100 patients, including 74 (74%) with PTB and 26 (26%) with EPTB, were enrolled. Positive smears were seen in 38 patients (38%). Lymph nodes were the most commonly involved organ in 14 of the 26 (53.8%) EPTB patients (13.5%). Seven (23.1%) of the EPTB patients were HIV-positive. Urine PCR was positive in only 28 patients (28%). Seven HIV-positive patients with PTB showed positive urine PCR results. Moreover, PCR results were positive in only one of the seven HIV-positive subjects with EPTB. Positive PCR results were found in 20 of the 73 HIV-negative patients (27.4%) and in 8 of the 27 HIV-positive patients (29.6%). Therefore, there was no significant difference between the HIV-negative and HIV-positive patients for urine PCR (sensitivity 29.6%, specificity 72.6%; positive and negative predictive values 28% and 72%, respectively; P = 0.138). Nested PCR showed the same sensitivity in HIV-positive and HIV-negative patients. It can be applied as a rapid technique for the diagnosis of TB.
Zandrino, Franco; La Paglia, Ernesto; Musante, Francesco
2010-01-01
To assess the diagnostic accuracy of magnetic resonance imaging in local staging of endometrial carcinoma, and to review the results and pitfalls described in the literature. Thirty women with a histological diagnosis of endometrial carcinoma underwent magnetic resonance imaging. Unenhanced T2-weighted and dynamic contrast-enhanced Ti-weighted sequences were obtained. Hysterectomy and salpingo-oophorectomy was performed in all patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the detection of deep myometrial and cervical infiltration. For deep myometrial infiltration T2-weighted sequences reached a sensitivity of 85%, specificity of 76%, PPV of 73%, NVP of 87%, and accuracy of 80%, while contrast-enhanced scans reached a sensitivity of 90%, specificity of 80%, PPV of 82%, NPV of 89%, and accuracy of 85%. For cervical infiltration T2-weighted sequences reached a sensitivity of 75%, specificity of 88%, PPV of 50%, NPV of 96%, and accuracy of 87%, while contrast-enhanced scans reached a sensitivity of 100%, specificity of 94%, PPV of 75%, NPV of 100%, and accuracy of 95%. Unenhanced and dynamic gadolinium-enhanced magnetic resonance allows accurate assessment of myometrial and cervical infiltration. Information provided by magnetic resonance imaging can define prognosis and management.
Chen, Qinghua; Raghavan, Prashant; Mukherjee, Sugoto; Jameson, Mark J; Patrie, James; Xin, Wenjun; Xian, Junfang; Wang, Zhenchang; Levine, Paul A; Wintermark, Max
2015-10-01
The aim of this study was to systematically compare a comprehensive array of magnetic resonance (MR) imaging features in terms of their sensitivity and specificity to diagnose cervical lymph node metastases in patients with thyroid cancer. The study included 41 patients with thyroid malignancy who underwent surgical excision of cervical lymph nodes and had preoperative MR imaging ≤4weeks prior to surgery. Three head and neck neuroradiologists independently evaluated all the MR images. Using the pathology results as reference, the sensitivity, specificity and interobserver agreement of each MR imaging characteristic were calculated. On multivariate analysis, no single imaging feature was significantly correlated with metastasis. In general, imaging features demonstrated high specificity, but poor sensitivity and moderate interobserver agreement at best. Commonly used MR imaging features have limited sensitivity at correctly identifying cervical lymph node metastases in patients with thyroid cancer. A negative neck MR scan should not dissuade a surgeon from performing a neck dissection in patients with thyroid carcinomas.
Seymer, A; Keinrath, P; Holzmannhofer, J; Pirich, C; Hergan, K; Meissnitzer, M W
2015-01-01
Objective: To prospectively analyse the diagnostic value of semi-quantitative breast-specific gamma imaging (BSGI) in the work-up of suspicious breast lesions compared with that of mammography (MG), breast ultrasound and MRI of the breast. Methods: Within a 15-month period, 67 patients with 92 breast lesions rated as Category IV or V according to the breast imaging reporting and data system detected with MG and/or ultrasound were included into the study. After the injection of 740–1110 MBq of Technetium-99m (99mTc) SestaMIBI intravenously, scintigrams were obtained in two projections comparable to MG. The BSGI was analysed visually and semi-quantitatively by calculating a relative uptake factor (X). With the exception of two patients with cardiac pacemakers, all patients underwent 3-T breast MRI. Biopsy results were obtained as the reference standard in all patients. Sensitivity, specificity, positive- and negative-predictive values, accuracy and area under the curve were calculated for each modality. Results: Among the 92 lesions, 67 (72.8%) were malignant. 60 of the 67 cancers of any size were detected by BSGI with an overall sensitivity of 90%, only exceeded by ultrasound with a sensitivity of 99%. The sensitivity of BSGI for lesions <1 cm declined significantly to 60%. Overall specificity of ultrasound was only 20%. Specificity, accuracy and positive-predictive value were the highest for BSGI (56%, 80% and 85%, respectively). X was significantly higher for malignant lesions (mean, 4.27) and differed significantly between ductal types (mean, 4.53) and the other histopathological entities (mean, 3.12). Conclusion: Semi-quantitative BSGI with calculation of the relative uptake factor (X) can help to characterize breast lesions. BSGI negativity may obviate the need for biopsy of breast lesions >1 cm with low or intermediate prevalence for malignancy. Advances in knowledge: Compared with morphological imaging modalities, specificity, positive-predictive value for malignancy and accuracy were the highest for BSGI in our study. BSGI negativity may support the decision not to biopsy in selected lesions with a low or low-to-moderate pre-test probability for malignancy. PMID:25882690
Buechel, Eva C.; Zhang, Jiao; Morewedge, Carey K.; Vosgerau, Joachim
2014-01-01
We propose that affective forecasters overestimate the extent to which experienced hedonic responses to an outcome are influenced by the probability of its occurrence. The experience of an outcome (e.g., winning a gamble) is typically more affectively intense than the simulation of that outcome (e.g., imagining winning a gamble) upon which the affective forecast for it is based. We suggest that, as a result, experiencers allocate a larger share of their attention toward the outcome (e.g., winning the gamble) and less to its probability specifications than do affective forecasters. Consequently, hedonic responses to an outcome are less sensitive to its probability specifications than are affective forecasts for that outcome. The results of 6 experiments provide support for our theory. Affective forecasters overestimated how sensitive experiencers would be to the probability of positive and negative outcomes (Experiments 1 and 2). Consistent with our attentional account, differences in sensitivity to probability specifications disappeared when the attention of forecasters was diverted from probability specifications (Experiment 3) or when the attention of experiencers was drawn toward probability specifications (Experiment 4). Finally, differences in sensitivity to probability specifications between forecasters and experiencers were diminished when the forecasted outcome was more affectively intense (Experiments 5 and 6). PMID:24128184
Buechel, Eva C; Zhang, Jiao; Morewedge, Carey K; Vosgerau, Joachim
2014-01-01
We propose that affective forecasters overestimate the extent to which experienced hedonic responses to an outcome are influenced by the probability of its occurrence. The experience of an outcome (e.g., winning a gamble) is typically more affectively intense than the simulation of that outcome (e.g., imagining winning a gamble) upon which the affective forecast for it is based. We suggest that, as a result, experiencers allocate a larger share of their attention toward the outcome (e.g., winning the gamble) and less to its probability specifications than do affective forecasters. Consequently, hedonic responses to an outcome are less sensitive to its probability specifications than are affective forecasts for that outcome. The results of 6 experiments provide support for our theory. Affective forecasters overestimated how sensitive experiencers would be to the probability of positive and negative outcomes (Experiments 1 and 2). Consistent with our attentional account, differences in sensitivity to probability specifications disappeared when the attention of forecasters was diverted from probability specifications (Experiment 3) or when the attention of experiencers was drawn toward probability specifications (Experiment 4). Finally, differences in sensitivity to probability specifications between forecasters and experiencers were diminished when the forecasted outcome was more affectively intense (Experiments 5 and 6).
López, Lissett; Venteo, Angel; Aguirre, Enara; García, Marga; Rodríguez, Majosé; Amusátegui, Inmaculada; Tesouro, Miguel A; Vela, Carmen; Sainz, Angel; Rueda, Paloma
2007-11-01
An indirect enzyme-linked immunosorbent assay (ELISA) based on baculovirus recombinant P30 protein of Ehrlichia canis and the 1BH4 anticanine IgG monoclonal antibody was developed and evaluated by examining a panel of 98 positive and 157 negative sera using the indirect fluorescent antibody (IFA) test as the reference technique. The P30-based ELISA appeared to be sensitive and specific (77.55% and 95.54%, respectively) when qualitative results (positive/negative) were compared with those of the IFA test; the coefficient of correlation (R) between the 2 tests was 0.833. Furthermore, it was possible to establish a mathematical formula for use in comparing the results of both techniques. These results indicate that recombinant P30 antigen-based ELISA is a suitable alternative of the IFA test for simple, consistent, and rapid serodiagnosis of canine ehrlichiosis. Moreover, the use of this recombinant protein as antigen offers a great advantage for antigen preparation in comparison with other techniques in which the whole E. canis organism is used as antigen.
Eco-friendly electron beam lithography using water-developable resist material derived from biomass
NASA Astrophysics Data System (ADS)
Takei, Satoshi; Oshima, Akihiro; Wakabayashi, Takanori; Kozawa, Takahiro; Tagawa, Seiichi
2012-07-01
We investigated the eco-friendly electron beam (EB) lithography using a high-sensitive negative type of water-developable resist material derived from biomass on hardmask layer for tri-layer processes. A water developable, non-chemically amplified, high sensitive, and negative tone resist material in EB lithography was developed for environmental affair, safety, easiness of handling, and health of the working people, instead of the common developable process of trimethylphenylammonium hydroxide. The images of 200 nm line and 800 nm space pattern with exposure dose of 7.0 μC/cm2 and CF4 etching selectivity of 2.2 with hardmask layer were provided by specific process conditions.
Sharma, Hemant P; Wood, Robert A; Bravo, Andrea R; Matsui, Elizabeth C
2008-04-01
Mouse sensitization is assessed by using skin testing and serum levels of mouse allergen-specific IgE (m-IgE). However, it is unknown whether a positive skin test response or m-IgE result accurately identifies those with clinically relevant mouse sensitization. We sought to compare skin testing and m-IgE measurement in the diagnosis of mouse allergy. Sixty-nine mouse laboratory workers underwent skin prick tests (SPTs), intradermal tests (IDTs), and serum IgE measurements to mouse allergen, followed by nasal challenge to increasing concentrations of mouse allergen. Challenge response was assessed by nasal symptom score. Thirty-eight women and 31 men with a mean age of 30 years were studied. Forty-nine workers reported mouse-related symptoms, of whom 10 had positive m-IgE results and 12 had positive SPT responses. Fifteen had negative SPT responses but positive IDT responses. Positive nasal challenges were observed in 70% of workers with positive m-IgE results, 83% of workers with positive SPT responses, 33% of workers with negative SPT responses/positive IDT responses, and 0% of workers with negative IDT responses. SPTs performed best, having the highest positive and negative predictive values. Among participants with a positive challenge result, those with a positive SPT response or m-IgE result had a significantly lower challenge threshold than those with a positive IDT response (P = .01). Workers with a positive challenge result were more likely to have an increase in nasal eosinophilia after the challenge compared with those with a negative challenge result (P = .03). SPTs perform best in discriminating patients with and without mouse allergy. Mouse-specific IgE and IDTs appear to be less useful than SPTs in the diagnosis of mouse allergy.
Clements, Michelle N; Donnelly, Christl A; Fenwick, Alan; Kabatereine, Narcis B; Knowles, Sarah C L; Meité, Aboulaye; N'Goran, Eliézer K; Nalule, Yolisa; Nogaro, Sarah; Phillips, Anna E; Tukahebwa, Edridah Muheki; Fleming, Fiona M
2017-12-01
The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous 'trace' result between 'positive' and 'negative', and much debate has focused on interpretation of traces results. We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d'Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence.
Swenson, David W; Pietryga, Jason A; Grand, David J; Chang, Kevin J; Murphy, Brian L; Egglin, Thomas K
2014-07-01
The purpose of this study was to compare the diagnostic performance of four radiographic signs of gastric band slippage: abnormal phi angle, the "O sign," inferior displacement of the superolateral gastric band margin, and presence of an air-fluid level above the gastric band. A search of the electronic medical record identified 21 patients with a surgically proven slipped gastric band and 63 randomly-selected asymptomatic gastric band patients who had undergone barium swallow studies. These studies were evaluated for the four signs of band slippage by two independent radiologists who were blinded to clinical data. Sensitivity, specificity, and positive and negative predictive values were calculated for each radiographic sign of band slippage. Interobserver agreement between radiologists was assessed using the Fleiss kappa statistic. In evaluating for gastric band slippage, an abnormal phi angle greater than 58° was 91-95% sensitive and 52-62% specific (κ = 0.78), the O sign was 33-48% sensitive but 97% specific (κ = 0.84), inferior displacement of the superolateral band margin by more than 2.4 cm from the diaphragm was 95% sensitive and 97-98% specific (κ = 0.97), and the presence of an air-fluid level was 95% sensitive and 100% specific (κ = 1.00). We report two previously undescribed radiographic signs of gastric band slippage that are both sensitive and specific for this important surgical complication and recommend that these signs should be incorporated into the imaging evaluation of gastric band patients.
Bozkurt, M; Yumru, A E; Aral, I
2013-01-01
The aim of this study was to investigate the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPPV) of the serum levels of CA-125, CA15-3, CA19-9, carcinoembryonic antigen (CEA), and alpha-fetoprotein (AFP) in the differentiation of benign and malignant ovarian tumors histopathologically diagnosed in patients and to determine the effects of the different test combinations on diagnostic accuracy. One-hundred sixty-eight patients that had their preoperative CA-125, CA15-3, CA19-9, CEA, AFP levels assessed and that were subsequently surgically treated for adnexal masses, were included in the study. For each tumor markers in these patients with histopathologically-confirmed diagnosis, the sensitivity, specificity, PPV and NPV, and diagnostic accuracy, and odds ratio were calculated. The sensitivity, specificity, PPV, NPV of CA125 with cut-off 35 U/ml, were found to be 78.9%, 86.9%, 63.8%, and 93.3%, respectively. The diagnostic odds ratio of CA-125 with cut-off of 35 U/ml, was found to be 25. With cut-off65 U/ml, the sensitivity, specificity, PPV, NPV values were 65.7%, 95.3%, 80.6%, and 90.5%, respectively. The sensitivity, specificity, PPV, and NPV of CEA were 16%, 93%, 37%, and 83%, respectively. For AFP, the sensitivity, specificity, PPV and NPV were to be 2.6%, 98%, 33.3%, and 77.5%, respectively. For CA 15-3, the sensitivity, specificity, PPV and NPV were found to be 26.3% 96.1%, 66.6%, and 81.6%, respectively. Likelihood ratio tests: positive (LR+) = 6.83 and negative (LR-) = 0.76, with an odds ratio: 8.9. The risk of malignancy for adnexal masses with higher CA15-3 increased by approximately nine times. For CA19-9, the sensitivity, specificity, PPV and NPV value were found to be 18.4%, 93%, 43.7%, and 79.6%, respectively. CA19-9 was not statistically significant in the differentiation of benign and malignant of adnexal masses. Even the combinations of CA125 + CEA + CA19-9 and CA125 + CEA + CA19-9 +AFP and CA125 + CA15-3 made a small contribution (one, two, and four cases, respectively), but was not statistically significant. The levels of CA-125 and CA15-3 were found to be significant in order to distinguish benign and malign; CA 19-9, CEA, and AFP were not found to be significant. The different test combinations did not have contribution for diagnostic accuracy.
Huang, Terry T-K; Nansel, Tonja R.; Belsheim, Allen R.; Morrison, John A.
2008-01-01
Objective To estimate the sensitivity, specificity, and predictive values of pediatric metabolic syndrome (MetS) components (obesity, fasting glucose, triglycerides, high-density lipoprotein, and blood pressure) at various cutoffs in relation to adult MetS. Study design Data from the NHLBI Lipid Research Clinics (LRC) Princeton Prevalence Study (1973–76) and the Princeton Follow-up Study (PFS, 2000-4) were used to calculate sensitivity, specificity, and positive and negative predictive values for each component at a given cutoff, as well as for aggregates of components. Results Individual pediatric components alone showed low to moderate sensitivity, high specificity, and moderate predictive values in relation to adult MetS. When all five pediatric MetS components were considered, the presence of at least one abnormality had higher sensitivity for adult MetS than individual components alone. When multiple abnormalities were mandatory for MetS, positive predictive value was high and sensitivity was low. Childhood body mass alone showed neither high sensitivity nor high positive predictive value for adult MetS. Conclusions Considering multiple metabolic variables in childhood can improve the predictive utility for adult MetS, compared to each component or body mass alone. MetS variables may be useful for identifying some at risk children for prevention interventions. PMID:18206687
A standardized model for predicting flap failure using indocyanine green dye
NASA Astrophysics Data System (ADS)
Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.
2016-03-01
Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.
Ben-Ishay, Offir; Daoud, Mai; Peled, Zvi; Brauner, Eran; Bahouth, Hany; Kluger, Yoram
2015-01-01
In pediatric care, the role of focused abdominal sonography in trauma (FAST) remains ill defined. The objective of this study was to assess the sensitivity and specificity of FAST for detecting free peritoneal fluid in children. The trauma registry of a single level I pediatric trauma center was queried for the results of FAST examination of consecutive pediatric (<18 years) blunt trauma patients over a period of 36 months, from January 2010 to December 2012. Demographics, type of injuries, FAST results, computerized tomography (CT) results, and operative findings were reviewed. During the study period, 543 injured pediatric patients (mean age 8.2 ± 5 years) underwent FAST examinations. In 95 (17.5 %) FAST was positive for free peritoneal fluid. CT examination was performed in 219 (40.3 %) children. Positive FAST examination was confirmed by CT scan in 61/73 (83.6 %). CT detected intra-peritoneal fluid in 62/448 (13.8 %) of the patients with negative FAST results. These findings correspond to a sensitivity of 50 %, specificity of 88 %, positive predictive value (PPV) of 84 %, and a negative predictive value (NPV) of 58 %. In patients who had negative FAST results and no CT examination (302), no missed abdominal injury was detected on clinical ground. FAST examination in the young age group (<2 years) yielded lower sensitivity and specificity (36 and 78 % respectively) with a PPV of only 50 %. This study shows that although a positive FAST evaluation does not necessarily correlate with an IAI, a negative one strongly suggests the absence of an IAI, with a high NPV. These findings are emphasized in the analysis of the subgroup of children less than 2 years of age. FAST examination tempered with sound clinical judgment seems to be an effective tool to discriminate injured children in need of further imaging evaluation.
Chan, E L; Brandt, K; Horsman, G
1995-11-01
Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.
Magnetic Resonance Enterography to Assess Multifocal and Multicentric Bowel Endometriosis.
Nyangoh Timoh, Krystel; Stewart, Zelda; Benjoar, Mikhael; Beldjord, Selma; Ballester, Marcos; Bazot, Marc; Thomassin-Naggara, Isabelle; Darai, Emile
To prospectively determine the accuracy of magnetic resonance enterography (MRE) compared with conventional magnetic resonance imaging (MRI) for multifocal (i.e., multiple lesions affecting the same digestive segment) and multicentric (i.e., multiple lesions affecting several digestive segments) bowel endometriosis. A prospective study (Canadian Task Force classification II-2). Tenon University Hospital, Paris, France. Patients with MRI-suspected colorectal endometriosis scheduled for colorectal resection from April 2014 to February 2016 were included. Patients underwent both 1.5-Tesla MRI and MRE as well as laparoscopically assisted and open colorectal resections. The diagnostic performance of MRI and MRE was evaluated for sensitivity, specificity, positive and negative predictive values, accuracy, and positive and negative likelihood ratios (LRs). The interobserver variability of the experienced and junior radiologists was quantified using weighted statistics. Forty-seven patients were included. Twenty-two (46.8%) patients had unifocal lesions, 14 (30%) had multifocal lesions, and 11 (23.4%) had multicentric lesions. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multifocal lesions were 0.29 (6/21), 1.00 (23/24), 15.36, and 0.71 for MRI and 0.57 (12/21), 0.89 (23/25), 4.95, and 0.58 for MRE. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multicentric lesions were 0.18 (1/11), 1.00 (1/1), 15, and 0.80 for MRI and 0.46 (5/11), 0.92 (33/36), 5.45, and 0.60 for MRE. Lower accuracies for MRI compared with MRE to diagnose multicentric (p = .01) and multifocal lesions (p = .004) were noted. The interobserver agreement for MRE was good for both multifocality (κ = 0.80) and multicentricity (κ = 0.61). MRE has better accuracy for diagnosing multifocal and multicentric bowel endometriosis than conventional MRI. Copyright © 2018. Published by Elsevier Inc.
Behera, B; Mathur, P; Gupta, B
2010-01-01
The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.
Egg hypersensitivity and measles-mumps-rubella vaccine administration.
Beck, S A; Williams, L W; Shirrell, M A; Burks, A W
1991-11-01
Because reports have described egg-sensitive individuals in whom anaphylaxis developed after measles vaccination, current recommendations include delaying administration of egg-derived vaccines until skin testing can be performed. Specifically, the 1988 Red Book recommends skin testing via scratch, prick, or puncture with 1:10 dilution of the vaccine and, if the result is negative, intradermal testing is suggested. The purpose of this study was to evaluate the likelihood of reaction to measles-mumps-rubella (MMR) vaccine in patients with documented egg sensitivity and to delineate the efficacy of skin-prick testing (SPT) to MMR as a predictor of hypersensitivity to the vaccine. Egg sensitivity was documented by initial SPT to egg and then, if possible, double-blind placebo-controlled food challenge (DBPCFC). Patients with a positive DBPCFC to egg or a history of anaphylactic egg sensitivity had a SPT with the MMR vaccine and then were given the MMR vaccine. Additionally, children with atopic dermatitis who had been previously proven egg sensitive via DBPCFCs were evaluated retrospectively for sensitivity to the MMR vaccine. Sixteen children with a history of egg sensitivity underwent SPT to egg, with a positive result 3 mm greater than the negative control found in 12 patients. Eight of these children had a positive DBPCFC to egg. The SPT to MMR vaccine was negative in all 16 children; vaccine administration followed with no resultant systemic problems. Three children had a local reaction at the site of injection. Twelve additional children with atopic dermatitis and egg sensitivity were reviewed. Each child had a positive SPT and DBPCFC to egg.(ABSTRACT TRUNCATED AT 250 WORDS)
Kirkland, Tabitha
2014-01-01
Although much is known about the neural dynamics of maladaptive affective styles, the mechanisms of happiness and well-being are less clear. One possibility is that the neural processes of trait happiness are the opposite of those involved in depression/anxiety: ‘rose-colored glasses’ cause happy people to focus on positive cues while remaining oblivious to threats. Specifically, because negative affective styles have been associated with increased amygdala activation to negative stimuli, it may be happy people will not show this enhanced response, and may even show reduced amygdala activation to negative stimuli. Alternatively, if well-being entails appropriate sensitivity to information, happy people may process any relevant cues—positive or negative—to facilitate appropriate responding. This would mean that happiness is associated with increased amygdala activation to both positive and negative stimuli. Forty-two participants viewed affective stimuli during functional magnetic resonance imaging scanning. Happier participants showed greater amygdala responses to positive stimuli. Moreover, no significant relationships were found between happiness and responses to negative stimuli. In other words, for happy people, a tuning toward positive did not come at the cost of losing sensitivity to negativity. This work suggests that trait happiness is associated with a balanced amygdala response to positivity and negativity. PMID:23563851
Evaluation of two real time PCR assays for the detection of bacterial DNA in amniotic fluid.
Girón de Velasco-Sada, Patricia; Falces-Romero, Iker; Quiles-Melero, Inmaculada; García-Perea, Adela; Mingorance, Jesús
2018-01-01
The aim of this study was to evaluate two non-commercial Real-Time PCR assays for the detection of microorganisms in amniotic fluid followed by identification by pyrosequencing. We collected 126 amniotic fluids from 2010 to 2015 for the evaluation of two Real-Time PCR assays for detection of bacterial DNA in amniotic fluid (16S Universal PCR and Ureaplasma spp. specific PCR). The method was developed in the Department of Microbiology of the University Hospital La Paz. Thirty-seven samples (29.3%) were positive by PCR/pyrosequencing and/or culture, 4 of them were mixed cultures with Ureaplasma urealyticum. The Universal 16S Real-Time PCR was compared with the standard culture (81.8% sensitivity, 97.4% specificity, 75% positive predictive value, 98% negative predictive value). The Ureaplasma spp. specific Real-Time PCR was compared with the Ureaplasma/Mycoplasma specific culture (92.3% sensitivity, 89.4% specificity, 50% positive predictive value, 99% negative predictive value) with statistically significant difference (p=0.005). Ureaplasma spp. PCR shows a rapid response time (5h from DNA extraction until pyrosequencing) when comparing with culture (48h). So, the response time of bacteriological diagnosis in suspected chorioamnionitis is reduced. Copyright © 2017 Elsevier B.V. All rights reserved.
Prediction of venous wound healing with laser speckle imaging.
van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha
2017-12-01
Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.
Enzymatic signal amplification for sensitive detection of intracellular antigens by flow cytometry.
Karkmann, U; Radbruch, A; Hölzel, V; Scheffold, A
1999-11-19
Flow cytometry is the method of choice for the analysis of single cells with respect to the expression of specific antigens. Antigens can be detected with specific antibodies either on the cell surface or within the cells, after fixation and permeabilization of the cell membrane. Using conventional fluorochrome-labeled antibodies several thousand antigens are required for clear-cut separation of positive and negative cells. More sensitive reagents, e.g., magnetofluorescent liposomes conjugated to specific antibodies permit the detection of less than 200 molecules per cell but cannot be used for the detection of intracellular antigens. Here, we describe an enzymatic amplification technique (intracellular tyramine-based signal amplification, ITSA) for the sensitive cytometric analysis of intracellular cytokines by immunofluorescence. This approach results in a 10 to 15-fold improvement of the signal-to-noise ratio compared to conventional fluorochrome labeled antibodies and permits the detection of as few as 300-400 intracellular antigens per cell.
Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas
2017-08-01
Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.
Comparison of serum specific IgE with skin prick test in the diagnosis of allergy in Malaysia.
Asha'ari, Z A; Suhaimi, Y; Yusof, R A; Rushdan, I; Maraina, C H C
2011-08-01
We compared a newer serum specific IgE (SSIgE) test with skin prick testing (SPT) in the diagnosis of allergy in Malaysia. Ninety newly diagnosed allergic patients were enrolled for both tests. Using SPT as a clinical gold standard, the sensitivity, specificity, positive, and negative predictive values (PPV, NPV) were calculated for SSIgE for each of the common allergens tested. The highest positive results for both SPT and SSIgE were for house dust mite and cat. Compared to SPT, SSIgE showed better sensitivity but poorer specificity, low PPV and good NPV in all the allergens tested. Significant positive correlation was seen between the diameter of wheal and flare of SPT and the SSIgE results.
McCloskey, Laura J; Christner, Paul; Jacobs-Kosmin, Dana; Jaskowski, Troy D; Hill, Harry R; Lakos, Gabriella; Teodorescu, Marius
2010-01-01
The myth persists that only the labor intensive Farr radioimmunoassay and Crithidia luciliae immunofluorescence (CL-IFA) are systemic lupus erythematosus (SLE)-specific tests. We compared them to ELISA with bacteriophage lambda DNA (EL-dsDNA) and denatured calf thymus DNA (EL-ssDNA). By percentile ranking, the specificity cut-off level was set both out of clinical context (SOCC) on 100 blood bank donors, and in clinical context (SICC) on 100 patients with either rheumatoid arthritis or scleroderma (50/50). Clinical sensitivity was calculated on 100 random SLE patients. At 95% SICC, the sensitivity of Farr, CL-IFA, EL-dsDNA, and EL-ssDNA was similar (95%CI): 76% (66-84), 76% (66-84), 63% (53-72), and 75% (65-83), respectively; 87% of the patients were positive by at least one method and 55%by all methods. At 99% SICC, the sensitivity was also similar (95% CI): 57% (47-67), 47% (37-57), 58% (47-67), and 43% (33-53), respectively. The areas under ROC curve were similar (95% CI) when patients were used as controls for specificity. At 99% SOCC, EL-ssDNA identified 89% positive, 2 negative but positive by another method at 95% SICC, and 9 negative (i.e. 89/2/9), followed by CL-IFA (80/6/14), Farr (76/12/12), and EL-dsDNA (64/23/13). Thus, at relatively low cost and easy automation, under the same conditions of specificity, the two ELISA tests combined were at least as good, if not superior, to CL-IFA or Farr: they showed similar clinical sensitivity and also identified more patients with anti-DNA antibodies. (c) 2010 Wiley-Liss, Inc.
Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao
2015-12-01
The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Mokhtarian, Kobra; Meamar, Ahmad Reza; Khoshmirsafa, Majid; Razmjou, Elham; Masoori, Leila; Khanmohammadi, Majid; Akhlaghi, Lame; Falak, Reza
2018-01-01
Laboratory diagnosis of sheep fasciolosis is commonly performed by coprological examinations; however, this method may lead to false negative results during the acute phase of the infection. Furthermore, the poor sensitivity of coprological methods is considered to be a paradox in the chronic phase of the infection. In this study, we compared the immunoreactivity of native and recombinant forms of Fasciola hepatica excretory/secretory antigens and determined their capabilities for the development of F. hepatica-specific immunoassays. Immunoreactivity and specificity of recombinant and native forms of F. hepatica antigens, including fatty acid binding protein (FABP), glutathione-S-transferase (GST), and cathepsin L-1 (CL1), in parallel with native forms of FABP and GST, were studied for serodiagnosis of the chronic form of sheep fasciolosis, individually or in combination with each other by enzyme-linked immunosorbent assays (ELISA). The correlation of the findings was assessed by receiver-operator characteristic (ROC); furthermore, the specificity and sensitivity were assessed by Youden's J. Serologic cross-reactivity was evaluated using samples from healthy sheep (n = 40), Fasciola-infected sheep (n = 30), and sheep with other parasitic infections (n = 43). The FABPs were determined to be greater than 95% sensitive for F. hepatica serodiagnosis. The most desirable diagnostic recombinant antigen was rCL1, which showed 100% sensitivity and 97% specificity in ELISA and was capable of discriminating the positive and negative samples by maximum Youden's J results. We conclude that rCL1 can be used for routine serodiagnosis of chronic fasciolosis. Thus, it could be advantageous in development of immunoassays for screening of ovine herds in fasciolosis-endemic areas and as a reliable agent for detection of fasciolosis in non-endemic regions.
Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus
2003-10-01
The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.
Al Saif, Amer; Alsenany, Samira
2015-01-01
[Purpose] To investigate the sensitivity and specificity of a newly developed diagnostic tool, the Amer Dizziness Diagnostic Scale (ADDS), to evaluate and differentially diagnose vestibular disorder and to identify the strengths and weaknesses of the scale and its usefulness in clinical practice. [Subjects and Methods] Two hundred subjects of both genders (72 males, 128 females) aged between 18 to 60 (49.5±7.8) who had a history of vertigo and/or dizziness symptoms for this previous two weeks or less were recruited for the study. All subjects were referred by otolaryngologists, neurologists or family physicians in and around Jeddah, Kingdom of Saudi Arabia. On the first clinic visit, all the patients were evaluated once using the ADDS, following which they underwent routine testing of clinical signs and symptoms, audiometry, and a neurological examination, coupled with tests of Vestibulo-Ocular Reflex function, which often serves as the "gold standard" for determining the probability of a vestibular deficit. [Results] The results show that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted and the results indicate that the ADDS was a significant predictor of "true-positive" and "true-negative" responses in vestibular disorders (R(2) =0.90). Approximately 90% of the variability in the vestibular gold standard test was explained by its relationship to the ADDS. Moreover, the ADDS was found to have a sensitivity of 96% and a specificity of 96%. [Conclusion] This study showed that the Amer Dizziness Diagnostic Scale has high sensitivity and specificity and that it can be used as a method of differential diagnosis for patients with vestibular disorders.
Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi
2008-07-01
To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.
Wu, Zheyang; Yang, Chun; Tang, Dalin
2011-06-01
It has been hypothesized that mechanical risk factors may be used to predict future atherosclerotic plaque rupture. Truly predictive methods for plaque rupture and methods to identify the best predictor(s) from all the candidates are lacking in the literature. A novel combination of computational and statistical models based on serial magnetic resonance imaging (MRI) was introduced to quantify sensitivity and specificity of mechanical predictors to identify the best candidate for plaque rupture site prediction. Serial in vivo MRI data of carotid plaque from one patient was acquired with follow-up scan showing ulceration. 3D computational fluid-structure interaction (FSI) models using both baseline and follow-up data were constructed and plaque wall stress (PWS) and strain (PWSn) and flow maximum shear stress (FSS) were extracted from all 600 matched nodal points (100 points per matched slice, baseline matching follow-up) on the lumen surface for analysis. Each of the 600 points was marked "ulcer" or "nonulcer" using follow-up scan. Predictive statistical models for each of the seven combinations of PWS, PWSn, and FSS were trained using the follow-up data and applied to the baseline data to assess their sensitivity and specificity using the 600 data points for ulcer predictions. Sensitivity of prediction is defined as the proportion of the true positive outcomes that are predicted to be positive. Specificity of prediction is defined as the proportion of the true negative outcomes that are correctly predicted to be negative. Using probability 0.3 as a threshold to infer ulcer occurrence at the prediction stage, the combination of PWS and PWSn provided the best predictive accuracy with (sensitivity, specificity) = (0.97, 0.958). Sensitivity and specificity given by PWS, PWSn, and FSS individually were (0.788, 0.968), (0.515, 0.968), and (0.758, 0.928), respectively. The proposed computational-statistical process provides a novel method and a framework to assess the sensitivity and specificity of various risk indicators and offers the potential to identify the optimized predictor for plaque rupture using serial MRI with follow-up scan showing ulceration as the gold standard for method validation. While serial MRI data with actual rupture are hard to acquire, this single-case study suggests that combination of multiple predictors may provide potential improvement to existing plaque assessment schemes. With large-scale patient studies, this predictive modeling process may provide more solid ground for rupture predictor selection strategies and methods for image-based plaque vulnerability assessment.
Chantratita, Narisara; Meumann, Ella; Thanwisai, Aunchalee; Limmathurotsakul, Direk; Wuthiekanun, Vanaporn; Wannapasni, Saran; Tumapa, Sarinna; Day, Nicholas P J; Peacock, Sharon J
2008-02-01
Melioidosis is a severe infection caused by Burkholderia pseudomallei. The timely implementation of effective antimicrobial treatment requires rapid diagnosis. Loop-mediated isothermal amplification (LAMP) targeting the TTS1 gene cluster was developed for the detection of B. pseudomallei. LAMP was sensitive and specific for the laboratory detection of this organism. The lower limit of detection was 38 genomic copies per reaction, and LAMP was positive for 10 clinical B. pseudomallei isolates but negative for 5 B. thailandensis and 5 B. mallei isolates. A clinical evaluation was conducted in northeast Thailand to compare LAMP to an established real-time PCR assay targeting the same TTS1 gene cluster. A total of 846 samples were obtained from 383 patients with suspected melioidosis, 77 of whom were subsequently diagnosed with culture-confirmed melioidosis. Of these 77 patients, a positive result was obtained from one or more specimens by PCR in 26 cases (sensitivity, 34%; 95% confidence interval [CI], 23.4 to 45.4%) and by LAMP in 34 cases (sensitivity, 44%; 95% CI, 32.8 to 55.9%) (P = 0.02). All samples from 306 patients that were culture negative for B. pseudomallei were negative by PCR (specificity, 100%; 95% CI, 98.8 to 100%), but 5 of 306 patients (1.6%) were positive by LAMP (specificity, 98.4%; 95% CI, 96.2 to 99.5%) (P = 0.03). The diagnostic accuracies of PCR and LAMP were 86.7% (95% CI, 82.9 to 89.9%) and 87.5% (95% CI, 83.7 to 90.6%), respectively (P = 0.47). Both assays were very insensitive when applied to blood samples; PCR and LAMP were positive for 0 and 1 of 44 positive blood cultures, respectively. The PCR and LAMP assays evaluated here are not sufficiently sensitive to replace culture in our clinical setting.
Relationship between milk cathelicidin abundance and microbiologic culture in clinical mastitis.
Addis, M F; Bronzo, V; Puggioni, G M G; Cacciotto, C; Tedde, V; Pagnozzi, D; Locatelli, C; Casula, A; Curone, G; Uzzau, S; Moroni, P
2017-04-01
The availability of reliable tools to enable the sensitive and specific detection of mastitis in dairy cows can assist in developing control strategies and promote the more rational use of antibiotics. We have developed a milk cathelicidin ELISA that shows high sensitivity and specificity for dairy cow mastitis, based on latent class analysis. In this study, we investigated the effect of microbial agents on cathelicidin abundance in the milk of cows with clinical mastitis. We subjected 535 quarter milk samples (435 from quarters showing signs of clinical mastitis and 100 from healthy quarters as a control) to milk cathelicidin ELISA, somatic cell count (SCC), and microbiologic culture. Of the 435 clinical mastitis samples, 431 (99.08%) were positive for cathelicidin, 424 (97.47%) had SCC >200,000 cells/mL, and 376 (86.44%) were culture-positive. Of the 59 culture-negative samples, 58 (98.30%) were positive for cathelicidin and 55 (93.22%) had SCC >200,000 cells/mL. The abundance of cathelicidin and the extent of SCC increase depended on the causative agent: Streptococcus agalactiae and coagulase-negative staphylococci showed the highest and lowest changes, respectively. We also observed differences in behavior between the 2 markers depending on the pathogen: Streptococcus agalactiae induced the highest cathelicidin abundance, and Serratia spp. induced the highest SCC. Nevertheless, the different ability of microorganisms to induce cathelicidin release in milk did not compromise its value as a mastitis marker, given its higher sensitivity compared to SCC or microbiologic culture. All 100 negative control samples (collected from healthy quarters with SCC <100,000 cells/mL and culture-negative) were also negative for cathelicidin, corresponding to 100% specificity in the evaluated sample cohort. This study confirmed the value of the milk cathelicidin ELISA for detecting bovine mastitis, and highlighted the influence of mastitis-causing microorganisms on cathelicidin abundance. This influence did not compromise diagnostic performance; instead, it may have better reflected disease severity and evolution than SCC. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen
2006-05-01
Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.
Moser, Dominik A.; Aue, Tatjana; Suardi, Francesca; Manini, Aurélia; Sancho Rossignol, Ana; Cordero, Maria I.; Merminod, Gaëlle; Ansermet, François; Rusconi Serpa, Sandra; Favez, Nicolas; Schechter, Daniel S.
2015-01-01
Socio-emotional information processing during everyday human interactions has been assumed to translate to social-emotional information processing when parenting a child. Yet, few studies have examined whether this is indeed the case. This study aimed to improve on this by connecting the functional neuroimaging data when seeing socio-emotional interactions that are not parenting specific to observed maternal sensitivity. The current study considered 45 mothers of small children (12–42 months of age). It included healthy controls (HC) and mothers with interpersonal violence-related posttraumatic stress disorder (IPV-PTSD), as well as mothers without PTSD, both with and without IPV exposure. We found that anterior cingulate cortex (ACC) and ventromedial prefrontal cortex (vmPFC) activity correlated negatively with observed maternal sensitivity when mothers watched videos of menacing vs. prosocial adult male–female interactions. This relationship was independent of whether mothers were HC or had IPV-PTSD. We also found dorsolateral prefrontal cortex (dlPFC) activity to be correlated negatively with maternal sensitivity when mothers watched any kind of arousing adult interactions. With regards to ACC and vmPFC activity, we interpret our results to mean that the ease of general emotional information integration translates to parenting-specific behavior. Our dlPFC activity findings support the idea that the efficiency of top-down control of socio-emotional processing in non-parenting specific contexts may be predictive of parenting behavior. PMID:26578996
Head-shaking nystagmus predicts greater disability in unilateral peripheral vestibulopathy.
Angeli, Simon I; Velandia, Sandra; Snapp, Hillary
2011-01-01
The objective of this study was to determine the association of the bedside test of head-shaking nystagmus (HSN) with patients' self-perceived dizziness handicap as well as this test's sensitivity and specificity in unilateral peripheral vestibular hypofunction. A retrospective case-control study was performed. The study was held at an academic, tertiary referral center. Fifty-three adult patients with unilateral peripheral hypofunction defined by the caloric test of the videonystagmography with documented bedside HSN and who had completed questionnaires of self-perceived dizziness handicap were included. The sensitivity and specificity of the bedside HSN in patients and 10 healthy controls in diagnosing unilateral vestibular hypofunction defined by videonystagmographic caloric testing and by abnormal gain and symmetry of the vestibular-ocular reflex by rotary chair testing were determined. Scores of the screening test of the Dizziness Handicap Index and Functional Level Scale questionnaires were taken. When using the caloric irrigation test as the reference standard for unilateral vestibular hypofunction, the sensitivity, specificity, and positive predictive value of the bedside HSN were 31%, 96%, and 97%, respectively. When comparing with results of rotational chair testing (vestibular-ocular reflex gain and symmetry), the sensitivity of the HSN test increases to 71%. Patients with positive bedside HSN had higher scores (greater self-perceived dizziness handicap) of the Dizziness Handicap Index (P = .049) and higher (worse) scores of the Functional Level Scale (P = .0377) than those with negative bedside HSN (Wilcoxon rank test). Greater perceived handicap was correlated with a positive bedside HSN in patients with unilateral peripheral vestibulopathy. The HSN has sufficient sensitivity to be used as screening test of uncompensated vestibulopathy in this series. However, a negative HSN alone does not rule out the diagnosis of peripheral vestibular dysfunction. Copyright © 2011 Elsevier Inc. All rights reserved.
Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.
2004-01-01
Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275
Van Limbergen, J; Kalima, P; Taheri, S; Beattie, T F
2006-01-01
Rapid streptococcal tests (RSTs) for streptococcal pharyngitis have made diagnosis at once simpler and more complicated. The American Academy of Pediatrics recommends that all RSTs be confirmed by a follow up throat culture unless local validation has proved the RST to be equally sensitive. To evaluate (a) RST as a single diagnostic tool, compared with RST with or without throat culture; (b) clinical diagnosis and the relative contribution of different symptoms. The study included 213 patients with clinical signs of pharyngitis. Throat swabs were analysed using Quickvue+ Strep A Test; negative RSTs were backed up by throat culture. Thirteen clinical features commonly associated with strep throat were analysed using backward stepwise logistic regression. Positive results (RST or throat culture) were obtained in 33 patients; RST correctly identified 21. Eleven samples were false negative on RST. At a strep throat prevalence of 15.9%, sensitivity of RST was 65.6% (95% CI 46.8% to 81.4%) and specificity 99.4% (96.7% to 99.9%). Sensitivity of clinical diagnosis alone was 57% (34% to 78%) and specificity 71% (61% to 80%). Clinically, only history of sore throat, rash, and pyrexia contributed to the diagnosis of strep throat (p<0.05). The high specificity of RST facilitates early diagnosis of strep throat. However, the low sensitivity of RST does not support its use as a single diagnostic tool. The sensitivity in the present study is markedly different from that reported by the manufacturer. Clinical examination is of limited value in the diagnosis of strep throat. It is important to audit the performance of new diagnostic tests, previously validated in different settings.
Van Limbergen, J; Kalima, P; Taheri, S; Beattie, T F
2006-01-01
Background Rapid streptococcal tests (RSTs) for streptococcal pharyngitis have made diagnosis at once simpler and more complicated. The American Academy of Pediatrics recommends that all RSTs be confirmed by a follow up throat culture unless local validation has proved the RST to be equally sensitive. Aims To evaluate (a) RST as a single diagnostic tool, compared with RST with or without throat culture; (b) clinical diagnosis and the relative contribution of different symptoms. Methods The study included 213 patients with clinical signs of pharyngitis. Throat swabs were analysed using Quickvue+ Strep A Test; negative RSTs were backed up by throat culture. Thirteen clinical features commonly associated with strep throat were analysed using backward stepwise logistic regression. Results Positive results (RST or throat culture) were obtained in 33 patients; RST correctly identified 21. Eleven samples were false negative on RST. At a strep throat prevalence of 15.9%, sensitivity of RST was 65.6% (95% CI 46.8% to 81.4%) and specificity 99.4% (96.7% to 99.9%). Sensitivity of clinical diagnosis alone was 57% (34% to 78%) and specificity 71% (61% to 80%). Clinically, only history of sore throat, rash, and pyrexia contributed to the diagnosis of strep throat (p<0.05). Conclusion The high specificity of RST facilitates early diagnosis of strep throat. However, the low sensitivity of RST does not support its use as a single diagnostic tool. The sensitivity in the present study is markedly different from that reported by the manufacturer. Clinical examination is of limited value in the diagnosis of strep throat. It is important to audit the performance of new diagnostic tests, previously validated in different settings. PMID:16373800
Phillips, Benjamin U; Dewan, Sigma; Nilsson, Simon R O; Robbins, Trevor W; Heath, Christopher J; Saksida, Lisa M; Bussey, Timothy J; Alsiö, Johan
2018-04-22
Dysregulation of the serotonin (5-HT) system is a pathophysiological component in major depressive disorder (MDD), a condition closely associated with abnormal emotional responsivity to positive and negative feedback. However, the precise mechanism through which 5-HT tone biases feedback responsivity remains unclear. 5-HT2C receptors (5-HT2CRs) are closely linked with aspects of depressive symptomatology, including abnormalities in reinforcement processes and response to stress. Thus, we aimed to determine the impact of 5-HT2CR function on response to feedback in biased reinforcement learning. We used two touchscreen assays designed to assess the impact of positive and negative feedback on probabilistic reinforcement in mice, including a novel valence-probe visual discrimination (VPVD) and a probabilistic reversal learning procedure (PRL). Systemic administration of a 5-HT2CR agonist and antagonist resulted in selective changes in the balance of feedback sensitivity bias on these tasks. Specifically, on VPVD, SB 242084, the 5-HT2CR antagonist, impaired acquisition of a discrimination dependent on appropriate integration of positive and negative feedback. On PRL, SB 242084 at 1 mg/kg resulted in changes in behaviour consistent with reduced sensitivity to positive feedback. In contrast, WAY 163909, the 5-HT2CR agonist, resulted in changes associated with increased sensitivity to positive feedback and decreased sensitivity to negative feedback. These results suggest that 5-HT2CRs tightly regulate feedback sensitivity bias in mice with consequent effects on learning and cognitive flexibility and specify a framework for the influence of 5-HT2CRs on sensitivity to reinforcement.
Lee, Chau Hung; Haaland, Benjamin; Earnest, Arul; Tan, Cher Heng
2013-09-01
To determine whether positive oral contrast agents improve accuracy of abdominopelvic CT compared with no, neutral or negative oral contrast agent. Literature was searched for studies evaluating the diagnostic performance of abdominopelvic CT with positive oral contrast agents against imaging with no, neutral or negative oral contrast agent. Meta-analysis reviewed studies correlating CT findings of blunt abdominal injury with positive and without oral contrast agents against surgical, autopsy or clinical outcome allowing derivation of pooled sensitivity and specificity. Systematic review was performed on studies with common design and reference standard. Thirty-two studies were divided into two groups. Group 1 comprised 15 studies comparing CT with positive and without oral contrast agents. Meta-analysis of five studies from group 1 provided no difference in sensitivity or specificity between CT with positive or without oral contrast agents. Group 2 comprised 17 studies comparing CT with positive and neutral or negative oral contrast agents. Systematic review of 12 studies from group 2 indicated that neutral or negative oral contrasts were as effective as positive oral contrast agents for bowel visualisation. There is no difference in accuracy between CT performed with positive oral contrast agents or with no, neutral or negative oral contrast agent. • There is no difference in the accuracy of CT with or without oral contrast agent. • There is no difference in the accuracy of CT with Gastrografin or water. • Omission of oral contrast, utilising neutral or negative oral contrast agent saves time, costs and decreases risk of aspiration.
McQueen, Margaret M; Duckworth, Andrew D; Aitken, Stuart A; Court-Brown, Charles M
2013-04-17
The aim of our study was to document the estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome. From our prospective trauma database, we identified all patients who had sustained a tibial diaphyseal fracture over a ten-year period. A retrospective analysis of 1184 patients was performed to record and analyze the documented use of continuous intracompartmental pressure monitoring and the use of fasciotomy. A diagnosis of acute compartment syndrome was made if there was escape of muscles at fasciotomy and/or color change in the muscles or muscle necrosis intraoperatively. A diagnosis of acute compartment syndrome was considered incorrect if it was possible to close the fasciotomy wounds primarily at forty-eight hours. The absence of acute compartment syndrome was confirmed by the absence of neurological abnormality or contracture at the time of the latest follow-up. Of 979 monitored patients identified, 850 fit the inclusion criteria with a mean age of thirty-eight years (range, twelve to ninety-four years), and 598 (70.4%) were male (p < 0.001). A total of 152 patients (17.9%) underwent fasciotomy for the treatment of acute compartment syndrome: 141 had acute compartment syndrome (true positives), six did not have it (false positives), and five underwent fasciotomy despite having a normal differential pressure reading, with subsequent operative findings consistent with acute compartment syndrome (false negatives). Of the 698 patients (82.1%) who did not undergo fasciotomy, 689 had no evidence of any late sequelae of acute compartment syndrome (true negatives) at a mean follow-up time of fifty-nine weeks. The estimated sensitivity of intracompartmental pressure monitoring for suspected acute compartment syndrome was 94%, with an estimated specificity of 98%, an estimated positive predictive value of 93%, and an estimated negative predictive value of 99%. The estimated sensitivity and specificity of continuous intracompartmental pressure monitoring for the diagnosis of acute compartment syndrome following tibial diaphyseal fracture are high; continuous intracompartmental pressure monitoring should be considered for patients at risk for acute compartment syndrome.
[Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].
Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian
2014-11-01
To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.
Rhee, H; Thomas, P; Shepherd, B; Gustafson, S; Vela, I; Russell, P J; Nelson, C; Chung, E; Wood, G; Malone, G; Wood, S; Heathcote, P
2016-10-01
Positron emission tomography using ligands targeting prostate specific membrane antigen has recently been introduced. Positron emission tomography imaging with (68)Ga-PSMA-HBED-CC has been shown to detect metastatic prostate cancer lesions at a high rate. In this study we compare multiparametric magnetic resonance imaging and prostate specific membrane antigen positron emission tomography of the prostate with whole mount ex vivo prostate histopathology to determine the true sensitivity and specificity of these imaging modalities for detecting and locating tumor foci within the prostate. In a prospective clinical trial setting 20 patients with localized prostate cancer and a planned radical prostatectomy were recruited. All patients underwent multiparametric magnetic resonance imaging and positron emission tomography before surgery, and whole mount histopathology slides were directly compared to the images. European Society of Urogenital Radiology guidelines for reporting magnetic resonance imaging were used as a template for regional units of analysis. The uropathologist and radiologists were blinded to individual components of the study, and the final correlation was performed by visual and deformable registration analysis. A total of 50 clinically significant lesions were identified from the whole mount histopathological analysis. Based on regional analysis the sensitivity, specificity, positive predictive value and negative predictive value for multiparametric magnetic resonance imaging were 44%, 94%, 81% and 76%, respectively. With prostate specific membrane antigen positron emission tomography the sensitivity, specificity, positive predictive value and negative predictive value were 49%, 95%, 85% and 88%, respectively. Prostate specific membrane antigen positron emission tomography yielded a higher specificity and positive predictive value. A significant proportion of cancers are potentially missed and underestimated by both imaging modalities. Prostate specific membrane antigen positron emission tomography may be used in addition to multiparametric magnetic resonance imaging to help improve local staging in those patients undergoing retropubic radical prostatectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Comparing diagnostic tests on benefit-risk.
Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott
2016-01-01
Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.
Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen
2016-10-01
To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.
Beynon, C M; Sumnall, H R; McVeigh, J; Cole, J C; Bellis, M A
2006-10-01
Assessment of the sensitivity and specificity of two commercially available 'drug-facilitated sexual assault' drug detector kits, Drink Guard and Drink Detective. Experimental. Laboratory. Gamma hydroxybutyrate (GHB) sodium salt, ketamine hydrochloride, temazepam, flunitrazepam and diazepam were dissolved (Tween added to benzodiazepine solutions) as separate stock solutions and added to 330 ml samples of cola (Pepsi Max), beer (Stella Artois), 'alcopop' (Bacardi Breezer) and placebo (distilled water). The doses used are reported to be common in cases of intoxication. Each kit was tested 10 times for each drink/drug combination. Two blind, independent observers scored each test (presence/absence of drug) in accordance with kit instructions; chi 2 was used to compare the proportion of times raters scored tests correctly and incorrectly. Sensitivity and specificity were calculated overall, for each drink, and sensitivity was calculated for each drug. Inter-observer agreement was evaluated using the kappa statistic. While both raters were able to score significantly more tests correctly than incorrectly using Drink Detective, and one rater scored similarly using Drink Guard, the overall sensitivity of Drink Detective and Drink Guard was 69.0% (95% CI 64.2-73.5%) and 37.5% (95% CI 30.1-45.5%), respectively. Sensitivity was drink-dependent. Drink Detective was unable to detect our dose of GHB in water, with all tests scored negatively by both raters for this drink/drug combination (n = 20 negative scores). Overall, specificity was 76.6% (95% CI 71.5-81.0%) and 87.9% (95% CI 83.0-91.6%) for Drink Guard and Drink Detective, respectively, but was affected by the beverage. Inter-rater agreement was poor for Drink Guard (kappa = 0.278 +/- 0.069) but excellent for Drink Detective (kappa = 0.894 +/- 0.245). Inter-observer agreement was drug-dependent. Use of drug detector kits by the public in the night-time environment needs further investigation and may create a false sense of security (false negatives) and undue concern (false positives) among kit users.
Zhang, Jian; Oueslati, Rania; Cheng, Cheng; Zhao, Ling; Chen, Jiangang; Almeida, Raul; Wu, Jayne
2018-07-30
Gram-negative bacteria are one of the most common microorganisms in the environment. Their differential detection and recognition from Gram-positive bacteria has been attracting much attention over the years. Using Escherichia coli (E. coli) as a model, we demonstrated on-site detection of Gram-negative bacteria by an AC electrokinetics-based capacitive sensing method using commercial microelectrodes functionalized with an aptamer specific to lipopolysaccharides. Dielectrophoresis effect was utilized to enrich viable bacteria to the microelectrodes rapidly, achieving a detection limit of 10 2 cells/mL within a 30 s' response time. The sensor showed a negligible response to Staphylococcus aureus (S. aureus), a Gram-positive species. The developed sensor showed significant advantages in sensitivity, selectivity, cost, operation simplicity, and response time. Therefore, this sensing method has shown great application potential for environmental monitoring, food safety, and real-time diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Causes of false-negative for high-grade urothelial carcinoma in urine cytology.
Lee, Paul J; Owens, Christopher L; Lithgow, Marie Y; Jiang, Zhong; Fischer, Andrew H
2016-12-01
The Paris System for classifying urine cytology emphasizes identification of high-grade urothelial carcinoma (HGUC). The causes of false-negative urine cytologies (UC) within this system are not well described. We identified 660 cases between 2005 and 2013 with both UC and subsequent cystoscopic biopsies. UC were classified as either Negative for HGUC or "Abnormal" ("Atypical", "Suspicious", and "Malignant"). Apparent false-negative cases were reviewed in a nonblinded fashion by two cytopathologists and two subspecialized genitourinary pathologists. A total of 199 of the 660 cases (30%) were histologically diagnosed as HGUC. The UC were "Abnormal" in 170/199 cases (sensitivity/specificity of 86%/71%). Twenty four apparent false negative cases were available for retrospective review. Five of 24 (21%) cystoscopic biopsies were found not to be HGUC on review (one false positive and four low-grade urothelial carcinoma (LGUC on review). Of the remaining 19 UC, 7 (29%) cytology samples were found to be truly negative on review, 11 (46%) were found to be Atypical, and 1 (4%) suspicious. Of the 12 UC that were at least "Atypical" with histologic HGUC on review: six misses (half) were attributed to obscuring inflammation/blood, four to poor preservation, eight to paucity of abnormal cells, and 1 case to interpretive error; many cases demonstrated overlapping reasons. About one fifth of apparent false negative diagnoses for HGUC can be because of overdiagnosis of HGUC by surgical pathologists. If poor preservation or obscured samples are called nondiagnostic, the sensitivity/specificity of UC for HGUC can be as high as 94%/71%. Diagn. Cytopathol. 2016;44:994-999. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Rhodes, Nathaniel J.; Richardson, Chad L.; Heraty, Ryan; Liu, Jiajun; Malczynski, Michael; Qi, Chao
2014-01-01
While a lack of concordance is known between gold standard MIC determinations and Vitek 2, the magnitude of the discrepancy and its impact on treatment decisions for extended-spectrum-β-lactamase (ESBL)-producing Escherichia coli are not. Clinical isolates of ESBL-producing E. coli were collected from blood, tissue, and body fluid samples from January 2003 to July 2009. Resistance genotypes were identified by PCR. Primary analyses evaluated the discordance between Vitek 2 and gold standard methods using cefepime susceptibility breakpoint cutoff values of 8, 4, and 2 μg/ml. The discrepancies in MICs between the methods were classified per convention as very major, major, and minor errors. Sensitivity, specificity, and positive and negative predictive values for susceptibility classifications were calculated. A total of 304 isolates were identified; 59% (179) of the isolates carried blaCTX-M, 47% (143) carried blaTEM, and 4% (12) carried blaSHV. At a breakpoint MIC of 8 μg/ml, Vitek 2 produced a categorical agreement of 66.8% and exhibited very major, major, and minor error rates of 23% (20/87 isolates), 5.1% (8/157 isolates), and 24% (73/304), respectively. The sensitivity, specificity, and positive and negative predictive values for a susceptibility breakpoint of 8 μg/ml were 94.9%, 61.2%, 72.3%, and 91.8%, respectively. The sensitivity, specificity, and positive and negative predictive values for a susceptibility breakpoint of 2 μg/ml were 83.8%, 65.3%, 41%, and 93.3%, respectively. Vitek 2 results in unacceptably high error rates for cefepime compared to those of agar dilution for ESBL-producing E. coli. Clinicians should be wary of making treatment decisions on the basis of Vitek 2 susceptibility results for ESBL-producing E. coli. PMID:24752253
Non-Culture Diagnostics for Invasive Candidiasis: Promise and Unintended Consequences
Clancy, Cornelius J.; Nguyen, M. Hong
2018-01-01
Blood cultures are positive for Candida species in < 50% and < 20% of hematogenously disseminated and intra-abdominal candidiasis, respectively. Non-culture tests such as mannan, anti-mannan antibody, Candida albicans germ tube antibody (CAGTA), 1,3-β-d-glucan (BDG), the T2Candida nanodiagnostic panel, and polymerase chain reaction (PCR) are available for clinical use, but their roles in patient care are uncertain. Sensitivity/specificity of combined mannan/anti-mannan, BDG, T2Candida and PCR for candidemia are ~80%/80%, ~80%/80%, ~90%/98%, and ~90%/90%, respectively. Limited data for intra-abdominal candidiasis suggest CAGTA, BDG sensitivity/specificity of ~65%/75% and PCR sensitivity of ~85–90%. PCR specificity has varied widely for intra-abdominal candidiasis (33–97%), and T2Candida data are lacking. Tests will be useful if restricted to cases in which positive and negative predictive values (PPVs, NPVs) differ in a clinically meaningful way from the pre-test likelihood of invasive candidiasis. In some patients, PPVs are sufficient to justify antifungal treatment, even if blood cultures are negative. In most patients, NPVs of each test are excellent, which may support decisions to withhold antifungal therapy. If test results are not interpreted judiciously, non-culture diagnostics may have unintended consequences for stewardship and infection prevention programs. In particular, discrepant non-culture test-positive/culture-negative results may promote inappropriate antifungal treatment of patients who are unlikely to have candidiasis, and lead to spurious reporting of hospital-acquired infections. In conclusion, non-culture Candida diagnostics have potential to advance patient care, but this promise will be realized only if users understand tests’ strengths and limitations, and plan proactively for how best to employ them at their hospitals. PMID:29463043
Wang, Lina; Li, Hao; Yang, Zhongyuan; Guo, Zhuming; Zhang, Quan
2015-07-01
This study was designed to assess the efficiency of the serum thyrotropin to thyroglobulin ratio for thyroid nodule evaluation in euthyroid patients. Cross-sectional study. Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China. Retrospective analysis was performed for 400 previously untreated cases presenting with thyroid nodules. Thyroid function was tested with commercially available radioimmunoassays. The receiver operating characteristic curves were constructed to determine cutoff values. The efficacy of the thyrotropin:thyroglobulin ratio and thyroid-stimulating hormone for thyroid nodule evaluation was evaluated in terms of sensitivity, specificity, positive predictive value, positive likelihood ratio, negative likelihood ratio, and odds ratio. In receiver operating characteristic curve analysis, the area under the curve was 0.746 for the thyrotropin:thyroglobulin ratio and 0.659 for thyroid-stimulating hormone. With a cutoff point value of 24.97 IU/g for the thyrotropin:thyroglobulin ratio, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 78.9%, 60.8%, 75.5%, 2.01, and 0.35, respectively. The odds ratio for the thyrotropin:thyroglobulin ratio indicating malignancy was 5.80. With a cutoff point value of 1.525 µIU/mL for thyroid-stimulating hormone, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 74.0%, 53.2%, 70.8%, 1.58, and 0.49, respectively. The odds ratio indicating malignancy for thyroid-stimulating hormone was 3.23. Increasing preoperative serum thyrotropin:thyroglobulin ratio is a risk factor for thyroid carcinoma, and the correlation of the thyrotropin:thyroglobulin ratio to malignancy is higher than that for serum thyroid-stimulating hormone. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio
2018-06-01
The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar
2015-01-01
Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055
Serrano-Gomez, Sergio; Burgos-Angulo, Gabriel; Niño-Vargas, Daniela Camila; Niño, María Eugenia; Cárdenas, María Eugenia; Chacón-Valenzuela, Estephania; McCosham, Diana Margarita; Peinado-Acevedo, Juan Sebastián; Lopez, M Marcos; Cunha, Fernando; Pazin-Filho, Antonio; Ilarraza, Ramses; Schulz, Richard; Torres-Dueñas, Diego
2017-01-01
Over 170 biomarkers are being investigated regarding their prognostic and diagnostic accuracy in sepsis in order to find new tools to reduce morbidity and mortality. Matrix metalloproteinases (MMPs) and their inhibitors have been recently studied as promising new prognostic biomarkers in patients with sepsis. This study is aimed at determining the utility of several cutoff points of these biomarkers to predict mortality in patients with sepsis. A multicenter, prospective, analytic cohort study was performed in the metropolitan area of Bucaramanga, Colombia. A total of 289 patients with sepsis and septic shock were included. MMP-9, MMP-2, tissue inhibitor of metalloproteinase 1 (TIMP-1), TIMP-2, TIMP-1/MMP-9 ratio, and TIMP-2/MMP-2 ratio were determined in blood samples. Value ranges were correlated with mortality to estimate sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiving operating characteristic curve. Sensitivity ranged from 33.3% (MMP-9/TIMP-1 ratio) to 60.6% (TIMP-1) and specificity varied from 38.8% (MMP-2/TIMP-2 ratio) to 58.5% (TIMP-1). As for predictive values, positive predictive value range was from 17.5% (MMP-9/TIMP-1 ratio) to 70.4% (MMP-2/TIMP-2 ratio), whereas negative predictive values were between 23.2% (MMP-2/TIMP-2 ratio) and 80.9% (TIMP-1). Finally, area under the curve scores ranged from 0.31 (MMP-9/TIMP-1 ratio) to 0.623 (TIMP-1). Although TIMP-1 showed higher sensitivity, specificity, and negative predictive value, with a representative population sample, we conclude that none of the evaluated biomarkers had significant predictive value for mortality.
Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K
2014-12-01
The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.
Kurokawa, T; Onuma, T; Shinagawa, A; Chino, Y; Kobayashi, M; Yoshida, Y
2018-05-16
The aims of the Fukui Cervical Cancer Screening (FCCS) study are to determine the frequency of women with high-risk HPV (hrHPV), whether HPV16 or HPV18 (HPV16/18), in the Japanese cancer screening population for the first time and to identify the best strategy for cervical cancer screening in Japan. This study enrolled 7,584 women ≥25 years of age who were undergoing routine screening. All women underwent liquid-based cytology and cobas HPV tests. Women with abnormal cytology, whether hrHPV positive or negative; women with hrHPV positivity with either normal or abnormal cytology; and women randomly selected from women with normal cytology and negative hrHPV negative were referred for colposcopy. The prevalences of hrHPV positivity and HPV16/18 positivity were 6.8% and 1.7%, respectively. The baseline data from the FCCS study showed that the combination of HPV tests and cytology was more sensitive than cytology with respect to the detection of intraepithelial neoplasia grade 2 or worse. However, the specificity (94.1%) of the co-testing strategy that required all women with abnormal cytology or hrHPV positivity to be referred for colposcopy was much lower than that (97.8%) of cytology. The sensitivity and specificity of the co-testing strategy that required only women with abnormal cytology or HPV16/18 positivity to undergo colposcopy were 85.5% and 97.0%, respectively. The baseline data from the FCCS study suggest that a cervical cancer screening strategy in which only women with abnormal cytology or HPV16/18 positivity undergo colposcopy offers a more balanced sensitivity and specificity than other strategies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Development and Validation of an Algorithm to Identify Planned Readmissions From Claims Data.
Horwitz, Leora I; Grady, Jacqueline N; Cohen, Dorothy B; Lin, Zhenqiu; Volpe, Mark; Ngo, Chi K; Masica, Andrew L; Long, Theodore; Wang, Jessica; Keenan, Megan; Montague, Julia; Suter, Lisa G; Ross, Joseph S; Drye, Elizabeth E; Krumholz, Harlan M; Bernheim, Susannah M
2015-10-01
It is desirable not to include planned readmissions in readmission measures because they represent deliberate, scheduled care. To develop an algorithm to identify planned readmissions, describe its performance characteristics, and identify improvements. Consensus-driven algorithm development and chart review validation study at 7 acute-care hospitals in 2 health systems. For development, all discharges qualifying for the publicly reported hospital-wide readmission measure. For validation, all qualifying same-hospital readmissions that were characterized by the algorithm as planned, and a random sampling of same-hospital readmissions that were characterized as unplanned. We calculated weighted sensitivity and specificity, and positive and negative predictive values of the algorithm (version 2.1), compared to gold standard chart review. In consultation with 27 experts, we developed an algorithm that characterizes 7.8% of readmissions as planned. For validation we reviewed 634 readmissions. The weighted sensitivity of the algorithm was 45.1% overall, 50.9% in large teaching centers and 40.2% in smaller community hospitals. The weighted specificity was 95.9%, positive predictive value was 51.6%, and negative predictive value was 94.7%. We identified 4 minor changes to improve algorithm performance. The revised algorithm had a weighted sensitivity 49.8% (57.1% at large hospitals), weighted specificity 96.5%, positive predictive value 58.7%, and negative predictive value 94.5%. Positive predictive value was poor for the 2 most common potentially planned procedures: diagnostic cardiac catheterization (25%) and procedures involving cardiac devices (33%). An administrative claims-based algorithm to identify planned readmissions is feasible and can facilitate public reporting of primarily unplanned readmissions. © 2015 Society of Hospital Medicine.
Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin
2010-06-01
Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.
Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui
2013-12-01
The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.
Sánchez-Rodríguez, Dolores; Annweiler, Cédric; Ronquillo-Moreno, Natalia; Tortosa-Rodríguez, Andrea; Guillén-Solà, Anna; Vázquez-Ibar, Olga; Escalada, Ferran; Muniesa, Josep M; Marco, Ester
Malnutrition is a prevalent condition related to adverse outcomes in older people. Our aim was to compare the diagnostic capacity of the malnutrition criteria of the European Society of Parenteral and Enteral Nutrition (ESPEN) with other classical diagnostic tools. Cohort study of 102 consecutive in-patients ≥70 years admitted for postacute rehabilitation. Patients were considered malnourished if their Mini-Nutritional Assessment-Short Form (MNA-SF) score was ≤11 and serum albumin <3 mg/dL or MNA-SF ≤ 11, serum albumin <3 mg/dL, and usual clinical signs and symptoms of malnutrition. Sensitivity, specificity, positive and negative predictive values, accuracy likelihood ratios, and kappa values were calculated for both methods: and compared with ESPEN consensus. Of 102 eligible in-patients, 88 fulfilled inclusion criteria and were identified as "at risk" by MNA-SF. Malnutrition diagnosis was confirmed in 11.6% and 10.5% of the patients using classical methods,whereas 19.3% were malnourished according to the ESPEN criteria. Combined with low albumin levels, the diagnosis showed 57.9% sensitivity, 64.5% specificity, 85.9% negative predictive value,0.63 accuracy (fair validity, low range), and kappa index of 0.163 (poor ESPEN agreement). The combination of MNA-SF, low albumin, and clinical malnutrition showed 52.6% sensitivity, 88.3% specificity, 88.3%negative predictive value, and 0.82 accuracy (fair validity, low range), and kappa index of 0.43 (fair ESPEN agreement). Malnutrition was almost twice as prevalent when diagnosed by the ESPEN consensus, compared to classical assessment methods: Classical methods: showed fair validity and poor agreement with the ESPEN consensus in assessing malnutrition in geriatric postacute care. Copyright © 2018 Elsevier B.V. All rights reserved.
Chang, Jung Wei; Kim, Jong Sung; Jung, Jin Gyu; Kim, Sung Soo; Yoon, Seok Joon; Jang, Hak Sun
2016-11-01
The Alcohol Use Disorder Identification Test (AUDIT) has been widely used to identify alcohol use disorder (AUD). This study evaluated the validity of the AUDIT-Korean revised version (AUDIT-KR) for screening AUD according to Diagnostic and Statistical Manual of Mental Disorders, fifth edition (DSM-5) criteria. This research was conducted with 443 subjects who visited the Chungnam National University Hospital for a comprehensive medical examination. All subjects completed the demographic questionnaire and AUDIT-KR without assistance. Subjects were divided into two groups according to DSM-5 criteria: an AUD group, which included patients that fit the criteria for AUD (120 males and 21 females), and a non-AUD group, which included 146 males and 156 females that did not meet AUD criteria. The appropriate cut-off values, sensitivity, specificity, and positive and negative predictive values of the AUDIT-KR were evaluated. The mean±standard deviation AUDIT-KR scores were 10.32±7.48 points in males and 3.23±4.42 points in females. The area under the receiver operating characteristic curve (95% confidence interval, CI) of the AUDIT-KR for identifying AUD was 0.884 (0.840-0.920) in males and 0.962 (0.923-0.985) in females. The optimal cut-off value of the AUDIT-KR was 10 points for males (sensitivity, 81.90%; specificity, 81.33%; positive predictive value, 77.2%; negative predictive value, 85.3%) and 5 points for females (sensitivity, 100.00%; specificity, 88.54%; positive predictive value, 52.6%; negative predictive value, 100.0%). The AUDIT-KR has high reliability and validity for identifying AUD according to DSM-5 criteria.
Ibrahim, Maryanne; Moyo, Sikhulile; Mohammed, Terence; Mupfumi, Lucy; Gaseitsiwe, Simani; Maswabi, Kenneth; Ajibola, Gbolahan; Gelman, Rebecca; Batlang, Oganne; Sakoi, Maureen; Auletta-Young, Chloe; Makhema, Joseph; Lockman, Shahin; Shapiro, Roger L
2017-08-15
HIV point-of-care (POC) testing allows for early infant HIV diagnosis and treatment, but POC accuracy at birth and in the setting of antiretroviral prophylaxis for the prevention of mother-to-child HIV transmission is unknown. We evaluated the Cepheid Xpert HIV-1 Qual POC test against the Roche Taqman HIV-1 DNA polymerase chain reaction (PCR) platform using dried blood spots from 15 HIV-infected and 75 HIV-exposed uninfected newborns. These infants were screened for HIV at <96 hours of life at 5 hospital maternity wards in Botswana; all infants received postexposure antiretroviral prophylaxis with single-dose nevirapine and zidovudine, and most mothers received 3-drug antiretroviral therapy in pregnancy and at delivery. Fourteen of the 15 PCR positive samples tested positive by Cepheid POC, yielding a sensitivity of 93.3% (95% confidence interval: 68.1 to 99.8). Baseline viral load among positive infants ranged from <40 to >10,000,000 copies/mL, with a median of 2403 copies/mL. The HIV RNA for the infant with false-negative POC testing was 1661 copies/mL. Of note, 2 infants with low HIV RNA (<40 and 272 copies/mL) were correctly identified as HIV positive by Cepheid POC. All the 75 PCR-negative samples tested negative by Cepheid POC, yielding a specificity of 100% (95% confidence interval: 96.1 to 100). Our study demonstrates high sensitivity and specificity for the Cepheid POC assay in the first week of life despite early infection and antiretroviral prophylaxis. This platform may be a useful approach for adding early infant HIV diagnosis to current testing programs.
Saito, Patricia Keiko; Yamakawa, Roger Haruki; Aparecida, Erica Pereira; da Silva Júnior, Waldir Verissimo; Borelli, Sueli Donizete
2014-01-01
Pre-transplant sensitization to human leukocyte antigens (HLA) is a risk factor for graft failure. Studies of the immunological profile related to anti-HLA antibodies in Brazilian renal transplant candidates are few. In this study, we evaluated the humoral immune response to HLA antigens in 269 renal transplant candidates, in Paraná State, Brazil. The HLA typing was performed by the polymerase chain reaction sequence-specific oligonucleotide method (PCR-SSO) combined with Luminex technology, using an SSO-LABType commercial kit (One Lambda, Inc., Canoga Park, CA, USA). The percentages of panel-reactive antibodies (PRA) and the specificity of anti-HLA antibodies were determined using the LS1PRA and LS2PRA commercial kits (One Lambda, Inc.). The PRA-positive group consisted of 182 (67.7%) patients, and the PRA-negative group of 87 (32.3%) patients. The two groups differed significantly only with respect to gender. Females were the most sensitized. Among the 182 patients with PRA- positive, 62 (34.1%) were positive for class I and negative for class II, 39 (21.4%) were negative for class I and positive for class II, and 81 (44.5%) were positive for both classes I and II. The HLA-A*02, A*24, A*01, B*44, B*35, B*15, DRB1*11, DRB1*04 and DRB1*03 allele groups were the most frequent. The specificities of anti-HLA antibodies were more frequent: A34, B57, Cw15, Cw16, DR51, DQ8 and DP14. This study documented the profile of anti-HLA antibodies in patients with chronic renal failure who were on waiting lists for an organ in Paraná, and found high sensitization to HLA antigens in the samples. PMID:24927116
Comparison of wheat and rye flour solutions for skin prick testing: a multi-centre study (Stad 1).
van Kampen, V; Merget, R; Rabstein, S; Sander, I; Bruening, T; Broding, H C; Keller, C; Muesken, H; Overlack, A; Schultze-Werninghaus, G; Walusiak, J; Raulf-Heimsoth, M
2009-12-01
Skin prick testing (SPT) is the basic method for diagnosing IgE-mediated allergies. However, skin reactivity is related to the quality of allergen extracts, which are often poorly defined for occupational allergens. To compare wheat and rye flour SPT solutions from different producers. Standardized SPTs were performed in seven allergy centres with wheat and rye flour solutions from four producers in 125 symptomatic bakers. Optimal cut-off levels for weal sizes were assessed with the Youden Index. Comparisons between SPT results of different solutions were made with flour-specific IgE (sIgE) as the gold standard. Sensitivities, specificities, positive and negative predictive values, and test efficiencies were calculated and compared with McNemar and chi(2)-tests. The influence of the choice of the gold standard (sIgE or challenge) test was examined for 95 subjects. Additionally, SPT solutions were analysed for protein and antigen content. The optimal cut-off level for all SPT solutions was a weal size of >or=1.5 mm. While differences between wheat and rye flours were small, differences between producers were important. Variability of sensitivities (0.31-0.96), negative predictive values (0.42-0.91), and test efficiencies (0.54-0.90) were higher than variations of specificities (0.74-1.00) and positive predictive values (0.88-1.00). Similar results were obtained when using challenge test results as the gold standard. Variability could be explained by the different antigen contents of the SPT solutions. There is a wide variability of SPT solutions for wheat and rye flour from different producers, mainly with respect to sensitivities, negative predictive values, and test efficiencies. Improvement and standardization of SPT solutions used for the diagnosis of baker's asthma are highly recommended.
Moreno Sánchez, T; Martín Hervás, C; Sola Martínez, E; Moreno Rodríguez, F
2014-01-01
The main objectives of this study were to evaluate the sensitivity and specificity of duplex Doppler ultrasonography in the study of hemodialysis peripheral vascular access dysfunction and to analyze the resistance index and flow in the afferent artery. We prospectively studied 178 patients with 178 peripheral vascular accesses that were dysfunctional in at least three consecutive hemodialysis sessions. Patients underwent duplex Doppler ultrasonography and clinical and laboratory follow-up for three months (provided angiography findings were negative). We calculated the sensitivity, specificity, predictive values, and coefficients of probability. We studied the morphology of the afferent artery, the arteriovenous anastomosis, and the efferent vein, and we measured the resistance index and the flow of the afferent artery, the diameter of the anastomosis, and the flow and peak systolic velocity in the efferent vein. The final sample consisted of 159 patients. The sensitivity, specificity, positive and negative predictive values, and positive and negative coefficients of probability were 0,98 (95% CI: 0,88-1.00), 0,74 (95% CI: 0,66-0,81), 0,96, 0,82, 3.7, and 0,03, respectively. The resistance index was less than 0,5 in 78.5% of the peripheral vascular accesses with normal function and greater than 0,5 in 86.1% of the dysfunctional peripheral vascular accesses. We found aneurysms in 19 of the native peripheral vascular accesses and pseudoaneurysms in 7 of the prosthetic grafts. Inverted flow was seen in 57 peripheral vascular accesses. Duplex Doppler ultrasonography is an efficacious method for detecting and characterizing stenosis and thrombosis in peripheral vascular accesses, and it provides information about the morphology and hemodynamics. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Quantitative relationship between the local lymph node assay and human skin sensitization assays.
Schneider, K; Akkan, Z
2004-06-01
The local lymph node assay (LLNA) is a new test method which allows for the quantitative assessment of sensitizing potency in the mouse. Here, we investigate the quantitative correlation between results from the LLNA and two human sensitization tests--specifically, human repeat insult patch tests (HRIPTs) and human maximization tests (HMTs). Data for 57 substances were evaluated, of which 46 showed skin sensitizing properties in human tests, whereas 11 yielded negative results in humans. For better comparability data from mouse and human tests were transformed to applied doses per skin area, which ranged over four orders of magnitude for the substances considered. Regression analysis for the 46 human sensitizing substances revealed a significant positive correlation between the LLNA and human tests. The correlation was better between LLNA and HRIPT data (n=23; r=0.77) than between LLNA and HMT data (n=38; r=0.65). The observed scattering of data points is related to various uncertainties, in part associated with insufficiencies of data from older HMT studies. Predominantly negative results in the LLNA for another 11 substances which showed no skin sensitizing activity in human maximization tests further corroborate the correspondence between LLNA and human tests. Based on this analysis, the LLNA can be considered a reliable basis for relative potency assessments for skin sensitizers. Proposals are made for the regulatory exploitation of the LLNA: four potency groups can be established, and assignment of substances to these groups according to the outcome of the LLNA can be used to characterize skin sensitizing potency in substance-specific assessments. Moreover, based on these potency groups, a more adequate consideration of sensitizing substances in preparations becomes possible. It is proposed to replace the current single concentration limit for skin sensitizers in preparations, which leads to an all or nothing classification of a preparation as sensitizing to skin ("R43") in the European Union, by differentiated concentration limits derived from the limits for the four potency groups.
Competitive Enzyme Immunoassay for Diagnosis of Human Brucellosis
Lucero, Nidia E.; Foglia, Luis; Ayala, Sandra M.; Gall, David; Nielsen, Klaus
1999-01-01
The methods commonly used for human brucellosis serological testing are agglutination tests and the complement fixation test (CFT). Among the newer serological tests, primary binding assays were developed to improve sensitivity and specificity. The competitive enzyme immunoassay (CELISA) for the detection of serum antibody to Brucella is a multispecies assay which appears to be capable of differentiating vaccinal and cross-reacting antibodies from antibodies elicited by field infection in cattle. The competing monoclonal antibody used in this assay is specific for a common epitope of smooth lipopolysaccharide (S-LPS). In this study, we compared the CELISA to the classical tests for the diagnosis of human brucellosis. The CELISA cutoff value was determined to calculate its diagnostic specificity and sensitivity. A survey was performed with 911 sera. Of the sera, 341 were from an asymptomatic population that tested negative with conventional serological tests (screening and confirmatory). Based on these samples, the CELISA specificities were determined to be 99.7 and 100% with cutoff values of 28 and 30% inhibition (%I), respectively. In a further study with 393 additional sera from an asymptomatic population found negative by the conventional screening tests, the CELISA specificities were calculated to be 96.5 and 98.8% with cutoff values of 28 and 30%I. The CELISA sensitivities were determined to be 98.3 and 94.8% with cutoff values of 28 and 30%I, respectively, for sera from 116 individuals found positive by the classical tests. For the 51 culture-positive patients, CELISA was positive for 100%, the CFT was positive for 92%, and the standard tube agglutination test (TAT) was positive for 100%. The CELISA specificity was 100% for 31 sera from patients found negative by conventional serological tests but with brucellosis-like symptoms. The CELISA is fairly rapid to perform, somewhat faster than TAT, and cross-reacts less with other antigens (or antibodies) than the conventional tests. Further, the CELISA is simpler to perform that the CFT and may readily be standardized by the use of purified S-LPS antigen and monoclonal antibody for competition. PMID:10488186
Lodh, Nilanjan; Mikita, Kei; Bosompem, Kwabena M; Anyan, William K; Quartey, Joseph K; Otchere, Joseph; Shiff, Clive J
2017-09-01
Schistosomes are easily transmitted and high chance of repeat infection, so if control strategies based on targeted mass drug administration (MDA) are to succeed it is essential to have a test that is sensitive, accurate and simple to use. It is known and regularly demonstrated that praziquantel does not always eliminate an infection so in spite of the successes of control programs a residual of the reservoir survives to re-infect snails. The issue of diagnostic sensitivity becomes more critical in the assessment of program effectiveness. While serology, such as antigen capture tests might improve sensitivity, it has been shown that the presence of species-specific DNA fragments will indicate, most effectively, the presence of active parasites. Polymerase chain reaction (PCR) can amplify and detect DNA from urine residue captured on Whatman No. 3 filter paper that is dried after filtration. Previously we have detected S. mansoni and S. haematobium parasite-specific small repeat DNA fragment from filtered urine on filter paper by PCR. In the current study, we assessed the efficacy of detection of 86 urine samples for either or both schistosome parasites by PCR and loop-mediated isothermal amplification (LAMP) that were collected from a low to moderate transmission area in Ghana. Two different DNA extraction methods, standard extraction kit and field usable LAMP-PURE kit were also evaluated by PCR and LAMP amplification. With S. haematobium LAMP amplification for both extractions showed similar sensitivity and specificity when compared with PCR amplification (100%) verified by gel electrophoresis. For S. mansoni sensitivity was highest for LAMP amplification (100%) for standard extraction than PCR and LAMP with LAMP-PURE (99% and 94%). The LAMP-PURE extraction produced false negatives, which require further investigation for this field usable extraction kit. Overall high positive and negative predictive values (90% - 100%) for both species demonstrated a highly robust approach. The LAMP approach is close to point of care use and equally sensitive and specific to detection of species-specific DNA by PCR. LAMP can be an effective means to detect low intensity infection due to its simplicity and minimal DNA extraction requirement. This will enhance the effectiveness of surveillance and MDA control programs of schistosomiasis. Copyright © 2017 Elsevier B.V. All rights reserved.
The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.
Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn
2015-12-01
To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95% CI, 67-93%) and 93% (95% CI, 89-96%). This meta-analysis shows considerable variation in techniques and reference standards for CT of myocardial blood supply. While CT seems sensitive and specific for evaluation of hemodynamically relevant CAD, studies so far are limited in size. Standardization of myocardial perfusion CT technique is essential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Slart, R; Jager, P; Poot, L; Piers, D; Cohen, T; Stegeman, C
2003-01-01
Background: Diagnosis of active pulmonary and paranasal involvement in patients with Wegener's granulomatosis (WG) can be difficult. The diagnostic value of gallium-67 scintigraphy in WG is unclear. Objective: To evaluate the added diagnostic value of gallium-67 scintigraphy in patients with WG with suspected granulomatous inflammation in the paranasal and chest regions. Methods: Retrospectively, the diagnostic contribution of chest and head planar gallium scans in 40 episodes of suspected vasculitis disease activity in 28 patients with WG was evaluated. Scans were grouped into normal or increased uptake for each region. Histological proof or response to treatment was the "gold standard" for the presence of WG activity. Results: WG activity was confirmed in 8 (20%) episodes, with pulmonary locations in three, paranasal in four, and both in one (n=7 patients); all these gallium scans showed increased gallium uptake (sensitivity 100%). Gallium scans were negative for the pulmonary area in 23/36 scans (specificity 64%), and negative for paranasal activity in 13/16 scans (specificity 81%) in episodes without WG activity. Positive predictive value of WG activity for lungs and paranasal region was 24% and 63%, respectively, negative predictive value was 100% for both regions. False positive findings were caused by bacterial or viral infections. Conclusion: Gallium scans are clinically helpful as a negative scan virtually excludes active WG. Gallium scintigraphy of chest and nasal region has a high sensitivity for the detection of disease activity in WG. However, because of positive scans in cases of bacterial or viral infections, specificity was lower. PMID:12810430
An intradermal skin test for determination of immunity to varicella
Somekh, E; Bujanover, Y; Tal, G; Dalal, I; Tanay, A; Lehman, D
2001-01-01
AIMS—To evaluate the usefulness of a diluted, inactivated solution of attenuated varicella vaccine in predicting susceptibility to varicella and its correlation with specific antibody titre to varicella. METHODS—In a prospective blinded study, 63 healthy subjects (aged 2-43 years) were studied. Skin test solution was prepared from vials of OKA strain virus which was inactivated by exposure of the vials to room temperature for 10 days; solution was diluted at 1/50 with normal saline and kept at 4°C until used for skin testing. The material was injected intradermally. Serum samples were drawn prior to skin testing and kept at −70°C until analysis for antibody assay by the indirect fluorescent antibody (IFA) method. RESULTS—Forty three patients were IFA antibody positive; 41 of them reacted to the skin test. One of the 20 IFA negative patients reacted to the skin test. Sixteen patients had two serological tests performed, one month apart. Four out of these 16 patients tested negative with the skin test. All four had negative serology on both samples. Six of the 12 IFA positive patients showed a boost in the antibody titre one month after application of the skin test. The specificity and sensitivity of the skin test compared to the IFA assay were both 95%, and the positive and negative predictive values were 97% and 90% respectively. CONCLUSIONS—Results suggest that a varicella skin test prepared using this simple and relatively cheap method is a safe, sensitive, and specific tool by which to assess immunity to varicella. PMID:11719333
Detection of lipoarabinomannan as a diagnostic test for tuberculosis.
Sada, E; Aguilar, D; Torres, M; Herrera, T
1992-01-01
A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favorable results were obtained for patients with AIDS and tuberculosis, with a sensitivity of 57%. The specificity in control patients with lung diseases different from tuberculosis and in healthy subjects was 100%. The positive predictive value was 100%, and the negative predictive value for patients with sputum-positive active pulmonary tuberculosis was 97%. The results of this study suggest that the detection of lipoarabinomannan is an accurate test for the diagnosis of pulmonary tuberculosis. PMID:1401008
Microarray-based IgE detection in tears of patients with vernal keratoconjunctivitis.
Leonardi, Andrea; Borghesan, Franco; Faggian, Diego; Plebani, Mario
2015-11-01
A specific allergen sensitization can be demonstrated in approximately half of the vernal keratoconjunctivitis (VKC) patients by conventional allergic tests. The measurement of specific IgE in tears using a multiplex allergen microarray may offer advantages to identify local sensitization to a specific allergen. In spring-summer 2011, serum and tears samples were collected from 10 active VKC patients (three females, seven males) and 10 age-matched normal subjects. Skin prick test, symptoms score and full ophthalmological examination were performed. Specific serum and tear IgE were assayed using ImmunoCAP ISAC, a microarray containing 103 components derived from 47 allergens. Normal subjects resulted negative for the presence of specific IgE both in serum and in tears. Of the 10 VKC patients, six resulted positive to specific IgE in serum and/or tears. In three of these six patients, specific IgE was found positive only in tears. Cross-reactivity between specific markers was found in three patients. Grass, tree, mites, animal but also food allergen-specific IgE were found in tears. Conjunctival provocation test performed out of season confirmed the specific local conjunctival reactivity. Multiple specific IgE measurements with single protein allergens using a microarray technique in tear samples are a useful, simple and non-invasive diagnostic tool. ImmunoCAP ISAC detects allergen sensitization at component level and adds important information by defining both cross- and co-sensitization to a large variety of allergen molecules. The presence of specific IgE only in tears of VKC patients reinforces the concept of possible local sensitization. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klech, H.; Kohn, H.; Kummer, F.
1982-12-01
The value of different factors are examined to assess activity in 60 patients with biopsy-proven sarcoidosis. In patients with active sarcoidosis (n . 35), /sup 67/Ga scans proved to be the most sensitive method (94 percent sensitivity), followed by serum angiotensin I converting enzyme (S-ACE) levels, chest x-ray films, and lymphocyte assays. In patients with peripheral pulmonary lesions, chest x-ray films failed in 32 percent of cases to document activity (68 percent sensitivity) whereas /sup 67/Ga scans and S-ACE levels remained to give reliable results. Despite poor specificity, negative /sup 67/Ga scans together with normal ACE levels have a highmore » predictive value for exclusion of active sarcoidosis. In patients with peripheral pulmonary lesions, chest roentgenography is of doubtful value for staging lung involvement and assessment of activity including monitoring and control of therapy.« less
Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin
2013-06-01
Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.
Nolan, Richard C; Richmond, Peter; Prescott, Susan L; Mallon, Dominic F; Gong, Grace; Franzmann, Annkathrin M; Naidoo, Rama; Loh, Richard K S
2007-05-01
Peanut allergy is transient in some children but it is not clear whether quantitating peanut-specific IgE by Skin Prick Test (SPT) adds additional information to fluorescent-enzyme immunoassay (FEIA) in discriminating between allergic and tolerant children. To investigate whether SPT with a commercial extract or fresh foods adds additional predictive information for peanut challenge in children with a low FEIA (<10 k UA/L) who were previously sensitized, or allergic to peanuts. Children from a hospital-based allergy service who were previously sensitized or allergic to peanuts were invited to undergo a peanut challenge unless they had a serum peanut-specific IgE>10 k UA/L, a previous severe reaction, or a recent reaction to peanuts (within two years). SPT with a commercial extract, raw and roasted saline soaked peanuts was performed immediately prior to open challenge in hospital with increasing quantity of peanuts until total of 26.7 g of peanut was consumed. A positive challenge consisted of an objective IgE mediated reaction occurring during the observation period. 54 children (median age of 6.3 years) were admitted for a challenge. Nineteen challenges were positive, 27 negative, five were indeterminate and three did not proceed after SPT. Commercial and fresh food extracts provided similar diagnostic information. A wheal diameter of >or=7 mm of the commercial extract predicted an allergic outcome with specificity 97%, positive predictive value 93% and sensitivity 83%. There was a tendency for an increase in SPT wheal since initial diagnosis in children who remained allergic to peanuts while it decreased in those with a negative challenge. The outcome of a peanut challenge in peanut sensitized or previously allergic children with a low FEIA can be predicted by SPT. In this cohort, not challenging children with a SPT wheal of >or=7 mm would have avoided 15 of 18 positive challenges and denied a challenge to one out of 27 tolerant children.
Hoferer, Marc; Braun, Anne; Skrypski, Julia; Bock, Sabine; Thalheim, Sabine; Sting, Reinhard
2017-09-01
Infectious pancreatic necrosis virus (IPNV) causes great losses in fish hatcheries world-wide. The detection of IPNV can be challenging in certain circumstances, particularly due to low viral load and the genetic variability of this RNA virus. For the first time, this project created a quantitative triplex real-time reverse transcription PCR (RT-qPCR), including an endogenous control system, for specific, sensitive and rapid detection of IPNV in routine diagnostics. Multiple sequence alignment of 46 nucleotide sequences of the segment A genome obtained from the NCBI database allowed the design of two RT-qPCR systems covering the IPNV genogroup 1 and genogroups 2-5, respectively. The completed triplex RT-qPCR including a salmonid-specific endogenous control showed high specificity and an analytical sensitivity of 20-40 oligonucleotide copies. Testing of dilution series of virus-loaded cell culture suspensions proved equality of the triplex RT-qPCR with virus detection in cell culture and a higher sensitivity than conventional RT-PCR in field samples. In comparative studies of a total of 77 field samples tested, 51 showed identical positive and 19 identical negative results in cell culture and the triplex RT-qPCR. However, seven other samples yielded positive results in the triplex RT-qPCR, but negative results in cell culture. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of a PCR Assay for the Detection of Spironucleus muris
Jackson, Glenn A; Livingston, Robert S; Riley, Lela K; Livingston, Beth A; Franklin, Craig L
2013-01-01
Spironucleus muris is a protozoan that can colonize the intestinal tract of many rodent species. Although its effects on animal health and research are debated, S. muris is often included on exclusion lists for rodent facilities. Common diagnostic tests for S. muris are insensitive and typically are performed at postmortem examination. We sought to develop a PCR-based diagnostic test with sufficient sensitivity and specificity for use on fecal samples from live rodents. We designed and optimized a PCR assay that targeted the 16S-like rRNA gene of S. muris. The assay was highly specific, given that samples from mice contaminated with S. muris were PCR positive, whereas samples from mice contaminated with other protozoa were negative. The assay also was highly sensitive, detecting as few as 5 template copies per microliter diluent. All mice positive for S. muris on postmortem exams also were positive by fecal PCR. Moreover, S. muris was detected by PCR in mice negative by postmortem examination but from colonies known to be contaminated as well as in rats and hamsters. To assess protozoal loads in mice of differing ages, the PCR assay was adapted to a quantitative format. Fecal loads of S. muris were highest in 4-wk-old mice and declined with age. The PCR assay developed promises to be a highly specific antemortem diagnostic assay with higher sensitivity than that of existing postmortem tests. PMID:23562099
Cho, Jin Seong; Kim, Ga-Eon; Lee, Ji Shin; Lee, Jae Hyuk; Nam, Jong Hee; Choi, Chan
2013-01-01
The aim of our study was to determine the diagnostic value of MUC1 and MUC4 for distinguishing between metastatic adenocarcinoma cells (MAC) and reactive mesothelial cells (RMC) in effusion fluids. A total of 237 cell block specimens from pleural and peritoneal effusions, including 196 malignant effusions with MAC and 41 benign effusions with RMC, were stained with antibodies against MUC1 and MUC4. Membranous staining with or without cytoplasmic staining was considered to be positive. MUC1 immunoreactivity was observed in 194 (99.0%) of 196 cases of MAC and in 20 (48.8%) of 41 cases of RMC. MUC4 immunoreactivity was observed in 174 (88.8%) of 196 cases of MAC and in 4 (9.8%) of 41 cases of RMC. For distinguishing MAC from RMC, the MUC1 reactivity was found to be 99.0% sensitive and 51.2% specific with a positive predictive value of 90.7% and a negative predictive value of 91.3%. The sensitivity of MUC4 for MAC was 88.8%, the specificity was 90.2%, the negative predictive value was 62.7%, and the positive predictive value was 97.8%. Our data suggest that MUC4 appears to be a sensitive and specific marker for differentiating between MAC and RMC. Copyright © 2013 S. Karger AG, Basel.
Rapid screening for inflammatory neuropathies by standardized clinical criteria
Tramontozzi, Louis A.
2016-01-01
Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273
Traynor, Damien; Duraipandian, Shiyamala; Martin, Cara M; O'Leary, John J; Lyng, Fiona M
2018-05-01
There is an unmet need for methods to help in the early detection of cervical precancer. Optical spectroscopy-based techniques, such as Raman spectroscopy, have shown great potential for diagnosis of different cancers, including cervical cancer. However, relatively few studies have been carried out on liquid-based cytology (LBC) pap test specimens and confounding factors, such as blood contamination, have been identified. Previous work reported a method to remove blood contamination before Raman spectroscopy by pretreatment of the slides with hydrogen peroxide. The aim of the present study was to extend this work to excessively bloody samples to see if these could be rendered suitable for Raman spectroscopy. LBC ThinPrep specimens were treated by adding hydrogen peroxide directly to the vial before slide preparation. Good quality Raman spectra were recorded from negative and high grade (HG) cytology samples with no blood contamination and with heavy blood contamination. Good classification between negative and HG cytology could be achieved for samples with no blood contamination (sensitivity 92%, specificity 93%) and heavy blood contamination (sensitivity 89%, specificity 88%) with poorer classification when samples were combined (sensitivity 82%, specificity 87%). This study demonstrates for the first time the improved potential of Raman spectroscopy for analysis of ThinPrep specimens regardless of blood contamination. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
2011-01-01
Background The botanical relation between grass and cereal grains may be relevant when diagnosing food allergy to cereals. The aim was to investigate the diagnostic specificity of skin prick test (SPT) and specific immunoglobulin E (sIgE) tests to cereals and peanut in grass pollen allergic subjects without history of, and clinically reactions to foods botanically related to grass. Methods 70 subjects (41 females; mean age 32 years) and 20 healthy controls (13 females; mean age 24 years) were tested by open food challenge (OFC) with cereals and peanut. SPT and sIgE both with Immulite® (Siemens) and ImmunoCAP® (Phadia) to grass and birch pollen, cereals, peanut and bromelain were performed. Results Of the 65 OFC-negative subjects 29-46% (SPT, depending on cut-off), 20% (Immulite) and 38% (ImmunoCAP) had positive results to one or more of the foods tested. Controls were negative in all tests. Cross-reactive carbohydrate determinants (CCD) as evidenced by reaction to bromelain could explain only a minority of the measured IgE-sensitizations. Conclusion Grass pollen allergic patients with documented food tolerance to cereals and peanut may express significant sensitization. False-positive cereal or peanut allergy diagnoses may be a quantitatively important problem both in routine clinical work and epidemiological studies. PMID:22409998
Cunningham, William A; Kirkland, Tabitha
2014-06-01
Although much is known about the neural dynamics of maladaptive affective styles, the mechanisms of happiness and well-being are less clear. One possibility is that the neural processes of trait happiness are the opposite of those involved in depression/anxiety: 'rose-colored glasses' cause happy people to focus on positive cues while remaining oblivious to threats. Specifically, because negative affective styles have been associated with increased amygdala activation to negative stimuli, it may be happy people will not show this enhanced response, and may even show reduced amygdala activation to negative stimuli. Alternatively, if well-being entails appropriate sensitivity to information, happy people may process any relevant cues-positive or negative-to facilitate appropriate responding. This would mean that happiness is associated with increased amygdala activation to both positive and negative stimuli. Forty-two participants viewed affective stimuli during functional magnetic resonance imaging scanning. Happier participants showed greater amygdala responses to positive stimuli. Moreover, no significant relationships were found between happiness and responses to negative stimuli. In other words, for happy people, a tuning toward positive did not come at the cost of losing sensitivity to negativity. This work suggests that trait happiness is associated with a balanced amygdala response to positivity and negativity. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Real, Ruben G. L.; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings. PMID:25309308
Real, Ruben G L; Kotchoubey, Boris; Kübler, Andrea
2014-01-01
This study aimed at evaluating the performance of the Studentized Continuous Wavelet Transform (t-CWT) as a method for the extraction and assessment of event-related brain potentials (ERP) in data from a single subject. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the t-CWT were assessed and compared to a variety of competing procedures using simulated EEG data at six low signal-to-noise ratios. Results show that the t-CWT combines high sensitivity and specificity with favorable PPV and NPV. Applying the t-CWT to authentic EEG data obtained from 14 healthy participants confirmed its high sensitivity. The t-CWT may thus be well suited for the assessment of weak ERPs in single-subject settings.
Evaluation of 5 different labeled polymer immunohistochemical detection systems.
Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A
2010-01-01
Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.
Soluble CD30 in patients with antibody-mediated rejection of the kidney allograft.
Slavcev, Antonij; Honsova, Eva; Lodererova, Alena; Pavlova, Yelena; Sajdlova, Helena; Vitko, Stefan; Skibova, Jelena; Striz, Ilja; Viklicky, Ondrej
2007-07-01
The aim of our retrospective study was to evaluate the clinical significance of measurement of the soluble CD30 (sCD30) molecule for the prediction of antibody-mediated (humoral) rejection (HR). Sixty-two kidney transplant recipients (thirty-one C4d-positive and thirty-one C4d-negative patients) were included into the study. Soluble CD30 levels were evaluated before transplantation and during periods of graft function deterioration. The median concentrations of the sCD30 molecule were identical in C4d-positive and C4d-negative patients before and after transplantation (65.5 vs. 65.0 and 28.2 vs. 36.0 U/ml, respectively). C4d+ patients who developed DSA de novo had a tendency to have higher sCD30 levels before transplantation (80.7+/-53.6 U/ml, n=8) compared with C4d-negative patients (65.0+/-33.4 U/ml, n=15). Soluble CD30 levels were evaluated as positive and negative (>or=100 U/ml and <100 U/ml respectively) and the sensitivity, specificity and accuracy of sCD30 estimation with regard to finding C4d deposits in peritubular capillaries were determined. The sensitivity of sCD30+ testing was generally below 40%, while the specificity of the test, i.e. the likelihood that if sCD30 testing is negative, C4d deposits would be absent, was 82%. C4d+ patients who developed DSA de novo were evaluated separately; the specificity of sCD30 testing for the incidence of HR in this cohort was 86%. We could not confirm in our study that high sCD30 levels (>or=100 U/ml) might be predictive for the incidence of HR. Negative sCD30 values might be however helpful for identifying patients with a low risk for development of DSA and antibody-mediated rejection.
Sensitivity, Specificity, PPV, and NPV for Predictive Biomarkers.
Simon, Richard
2015-08-01
Molecularly targeted cancer drugs are often developed with companion diagnostics that attempt to identify which patients will have better outcome on the new drug than the control regimen. Such predictive biomarkers are playing an increasingly important role in precision oncology. For diagnostic tests, sensitivity, specificity, positive predictive value, and negative predictive are usually used as performance measures. This paper discusses these indices for predictive biomarkers, provides methods for their calculation with survival or response endpoints, and describes assumptions involved in their use. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Colonic polyps: application value of computer-aided detection in computed tomographic colonography.
Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan
2011-02-01
Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.
LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.
Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel
2017-01-07
Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.
Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.
Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S
2016-02-01
Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.
Gomez, Jessie A; Carter, Alice S; Forbes, Danielle; Gray, Sarah A O
2018-06-01
Utilizing a two-dimensional model of parenting emphasizing both (1) proximity seeking and (2) exploration, consistent with a conceptual framework rooted in attachment theory, the relations between parental insightfulness, observed parenting, and child cognitive outcomes were investigated in a low-income sample of 64 of caregivers and their young 3-5-year-old children. Specifically, observed parental sensitivity (proximity seeking) and intrusiveness (exploration) and parental insightfulness assessed dimensionally to capture Positive Insight and Focus on Child were examined in relation to child cognitive outcomes. Parental intrusiveness was negatively correlated with cognitive performance; however, parental sensitivity was not associated with child cognitive outcomes. Parents' capacity to remain child-focused during the Insightfulness Assessment was negatively correlated with observed intrusiveness and was associated with child cognitive performance. These results suggest unique contributions of dimensions of parental insightfulness and parenting behaviors to child cognitive outcomes - specifically, parents' capacity to remain focused on children's experience during the Insightfulness Assessment and nonintrusive parenting behavior, which may reflect strategies to support children's exploration.
NASA Astrophysics Data System (ADS)
de Siqueira e Oliveira, Fernanda SantAna; Giana, Hector Enrique; Silveira, Landulfo
2012-10-01
A method, based on Raman spectroscopy, for identification of different microorganisms involved in bacterial urinary tract infections has been proposed. Spectra were collected from different bacterial colonies (Gram-negative: Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, Pseudomonas aeruginosa and Enterobacter cloacae, and Gram-positive: Staphylococcus aureus and Enterococcus spp.), grown on culture medium (agar), using a Raman spectrometer with a fiber Raman probe (830 nm). Colonies were scraped from the agar surface and placed on an aluminum foil for Raman measurements. After preprocessing, spectra were submitted to a principal component analysis and Mahalanobis distance (PCA/MD) discrimination algorithm. We found that the mean Raman spectra of different bacterial species show similar bands, and S. aureus was well characterized by strong bands related to carotenoids. PCA/MD could discriminate Gram-positive bacteria with sensitivity and specificity of 100% and Gram-negative bacteria with sensitivity ranging from 58 to 88% and specificity ranging from 87% to 99%.
European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W
2017-04-01
The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.
Snyder, James W.; Munier, Gina K.; Johnson, Charles L.
2010-01-01
This study compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay to culture by the use of BBL CHROMagar MRSA for the detection of MRSA in 627 nasal surveillance specimens collected from intensive care unit (ICU) patients. The PCR assay had a sensitivity, specificity, positive predictive value, and negative predictive value of 100%, 96.7%, 70.3%, and 100%, respectively. Nine of 19 false-positive PCR specimens grew methicillin-susceptible S. aureus (MSSA) from broth enrichment culture, of which two demonstrated evidence of mecA gene dropout. Compared to culture by the use of BBL CHROMagar MRSA, the BD GeneOhm MRSA PCR assay demonstrated sensitivity and specificity above 95% for the detection of MRSA nasal colonization and provided shorter turnaround time in generating positive and negative final results. PMID:20181916
Validation of the 4P's Plus screen for substance use in pregnancy validation of the 4P's Plus.
Chasnoff, I J; Wells, A M; McGourty, R F; Bailey, L K
2007-12-01
The purpose of this study is to validate the 4P's Plus screen for substance use in pregnancy. A total of 228 pregnant women enrolled in prenatal care underwent screening with the 4P's Plus and received a follow-up clinical assessment for substance use. Statistical analyses regarding reliability, sensitivity, specificity, and positive and negative predictive validity of the 4Ps Plus were conducted. The overall reliability for the five-item measure was 0.62. Seventy-four (32.5%) of the women had a positive screen. Sensitivity and specificity were very good, at 87 and 76%, respectively. Positive predictive validity was low (36%), but negative predictive validity was quite high (97%). Of the 31 women who had a positive clinical assessment, 45% were using less than 1 day per week. The 4P's Plus reliably and effectively screens pregnant women for risk of substance use, including those women typically missed by other perinatal screening methodologies.
Gil Montalbán, Elisa; Ortiz Marrón, Honorato; López-Gay Lucio-Villegas, Dulce; Zorrilla Torrás, Belén; Arrieta Blanco, Francisco; Nogales Aguado, Pedro
2014-01-01
To assess the validity and concordance of diabetes data in the electronic health records of primary care (Madrid-PC) by comparing with those from the PREDIMERC study. The sensitivity, specificity, positive predictive value, negative predictive value and kappa index of diabetes cases recorded in the health records of Madrid-PC were calculated by using data from PREDIMERC as the gold standard. The prevalence of diabetes was also determined according to each data source. The sensitivity of diabetes recorded in Madrid-PC was 74%, the specificity was 98.8%, the positive predictive value was 87.9%, the negative predictive value was 97.3%, and the kappa index was 0.78. The prevalence of diabetes recorded in Madrid-PC was 6.7% versus 8.1% by PREDIMERC, where known diabetes was 6.3%. The electronic health records of primary care are a valid source for epidemiological surveillance of diabetes in Madrid. Copyright © 2013 SESPAS. Published by Elsevier Espana. All rights reserved.
Biggs, Timothy C; Hayes, Stephen M; Bird, Jonathan H; Harries, Philip G; Salib, Rami J
2013-10-01
To evaluate the predictive diagnostic accuracy of the lymphocyte count in Epstein-Barr virus-related infectious mononucleosis (IM). Retrospective case note and blood results review within a university-affiliated teaching hospital. A retrospective review of 726 patients undergoing full blood count and Monospot testing was undertaken. Monospot testing outcomes were compared with the lymphocyte count, examining for significant statistical correlations. With a lymphocyte count of ≤4 × 10(9) /L, 99% of patients had an associated negative Monospot result (sensitivity of 84% and specificity of 94%). A group subanalysis of the population older than 18 years with a lymphocyte count ≤4 × 10(9) /L revealed that 100% were Monospot negative (sensitivity of 100% and specificity of 97%). A lymphocyte count of ≤4 × 10(9) /L correlated significantly with a negative Monospot result. A lymphocyte count of ≤4 × 10(9) /L appears to be a highly reliable predictor of a negative Monospot result, particularly in the population aged >18 years. Pediatric patients, and adults with strongly suggestive symptoms and signs of IM, should still undergo Monospot testing. However, in adults with more subtle symptoms and signs, representing the vast majority, Monospot testing should be restricted to those with a lymphocyte count >4 × 10(9) /L. NA Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B
2017-10-01
To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants. Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.
[Diagnostic accuracy of fine needle aspiration cytology in parotid tumours].
Zerpa Zerpa, Vanessa; Cuesta Gonzáles, Maria Teresa; Agostini Porras, Gabriela; Marcano Acuña, Martin; Estellés Ferriol, Enrique; Dalmau Galofre, José
2014-01-01
Fine needle aspiration cytology (FNAC) is a globally accepted technique in the preoperative evaluations of head and neck tumours; however, the effectiveness in the interpretation of salivary glands neoplastic lesions is still controversial. The objective of this study consisted of assessing the efficacy of FNAC in preoperative diagnosis of parotid tumours. This retrospective study was conducted using 93 patient samples with parotid gland tumoral pathology, treated at the Otorhinolaryngology Department in our institution during the 2007-2011 period. Preoperative FNAC was employed and the patients subsequently submitted to surgical excision with histopathological diagnosis of the specimen. Cytology results were classified as negative for malignancy, positive for malignancy or insufficient sample, and later compared with the definitive histological diagnosis. The mean age of the studied sample was 52.9 years (range: 11 to 88 years); 55.9% were men. The FNAC showed significant sensitivity of 57.1%, with a specificity of 95.1%, for detecting malignancy in parotid gland tumours. The positive and negative predictive values for malignancy were 50 and 96.3%, respectively. FNAC is considered a simple test but of limited use for diagnostic guidance in tumour pathology of the parotid gland in our environment, mainly because of its low sensitivity. However, the high specificity and high negative predictive value of FNAC makes it a more accurate test in benign or negative result cases. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Payne, Ann; Barry, Sandra; Creedon, Brian; Stone, Carol; Sweeney, Catherine; O' Brien, Tony; O' Sullivan, Kathleen
2007-04-01
The primary objective in this study is to determine the sensitivity and specificity of a two-item screening interview for depression versus the formal psychiatric interview, in the setting of a specialist palliative in-patient unit so that we may identify those individuals suffering from depressive disorder and therefore optimise their management in this often-complex population. A prospective sample of consecutive admissions (n = 167) consented to partake in the study, and the screening interview was asked separately to the formal psychiatric interview. The two-item questionnaire, achieved a sensitivity of 90.7% (95% CI 76.9-97.0) but a lower specificity of 67.7% (95% CI 58.7-75.7). The false positive rate was 32.3% (95% CI 24.3-41.3), but the false negative rate was found to be a low 9.3% (95% CI 3.0-23.1). A subgroup analysis of individuals with a past experience of depressive illness, (n = 95), revealed that a significant number screened positive for depression by the screening test, 55.2% (16/29) compared to those with no background history of depression, 33.3% (22/66) (P = 0.045). The high sensitivity and low false negative rate of the two-question screening tool will aid health professionals in identifying depression in the in-patient specialist palliative care unit. Individuals, who admit to a previous experience of depressive illness, are more likely to respond positively to the two-item questionnaire than those who report no prior history of depressive illness (P = 0.045).
Mahajan, Reena; Moorman, Anne C; Liu, Stephen J; Rupp, Loralee; Klevens, R Monina
2013-05-01
With increasing use electronic health records (EHR) in the USA, we looked at the predictive values of the International Classification of Diseases, 9th revision (ICD-9) coding system for surveillance of chronic hepatitis B virus (HBV) infection. The chronic HBV cohort from the Chronic Hepatitis Cohort Study was created based on electronic health records (EHR) of adult patients who accessed services from 2006 to 2008 from four healthcare systems in the USA. Using the gold standard of abstractor review to confirm HBV cases, we calculated the sensitivity, specificity, positive and negative predictive values using one qualifying ICD-9 code versus using two qualifying ICD-9 codes separated by 6 months or greater. Of 1 652 055 adult patients, 2202 (0.1%) were confirmed as having chronic HBV. Use of one ICD-9 code had a sensitivity of 83.9%, positive predictive value of 61.0%, and specificity and negative predictive values greater than 99%. Use of two hepatitis B-specific ICD-9 codes resulted in a sensitivity of 58.4% and a positive predictive value of 89.9%. Use of one or two hepatitis B ICD-9 codes can identify cases with chronic HBV infection with varying sensitivity and positive predictive values. As the USA increases the use of EHR, surveillance using ICD-9 codes may be reliable to determine the burden of chronic HBV infection and would be useful to improve reporting by state and local health departments.
Prenatal diagnosis using polymerase chain reaction on amniotic fluid for congenital toxoplasmosis.
Romand, S; Wallon, M; Franck, J; Thulliez, P; Peyron, F; Dumon, H
2001-02-01
To evaluate sensitivity, specificity, and predictive values of a prenatal amniotic fluid (AF) polymerase chain reaction (PCR) test for diagnosis of congenital toxoplasmosis. A multicenter prospective study was done on 271 women with proved primary Toxoplasma infection during pregnancy and who had amniocentesis for prenatal diagnosis by PCR. Live-born infants were eligible for analysis only if a serologic follow-up could assess a definitive infection status. Of the 270 evaluable cases, 75 were congenitally infected, 48 of whom had a positive PCR at prenatal diagnosis. Overall sensitivity of PCR on AF was estimated at 64% (95% confidence interval [CI] 53.1%, 74.9%), negative predictive value of 87.8% (95% CI 83.5%, 92.1%), whereas specificity and positive predictive value were 100% (95% CIs 98%, 100% and 92.3%, 100%, respectively). Among cases with congenital toxoplasmosis, there were no significant differences between those with positive or negative PCR with regard to median gestational age at maternal infection, interval between maternal infection and amniocentesis, or duration of treatment before amniocentesis. However, sensitivity of PCR was found to be significantly higher for maternal infections that occurred between 17 and 21 weeks' gestation (P <.02). A negative PCR of AF cannot rule out congenital infection. In this case, continuation of treatment with spiramycin combined with ultrasonographic follow-up and postnatal follow-up are warranted. Our results also suggest presumptive treatment combining pyrimethamine and sulfonamides in case of maternal infection occurring late in pregnancy.
Metrock, Laura K; Summers, Ryan J; Park, Sunita; Gillespie, Scott; Castellino, Sharon; Lew, Glen; Keller, Frank G
2017-10-01
Childhood acute leukemia is traditionally diagnosed from a bone marrow aspirate (BMA). New-onset acute leukemia patients do not always have visible circulating blasts in the peripheral blood (PB) at diagnosis. While the role of bone marrow flow cytometry for the diagnosis of acute leukemia is well established, the utility of PB flow cytometry (PBFC) is unknown. We performed a single-institution retrospective analysis to compare PBFC versus BMA in establishing or excluding a diagnosis of childhood acute leukemia. We retrospectively identified 485 PBFC samples with concurrent BMA from 2008 to 2013. Results of four-color flow cytometry for immunophenotypic characterization of leukemic versus nonclonal disease were characterized. Sensitivity and specificity were calculated among patients without a known diagnosis or prior therapy. Among 485 samples eligible for analysis, 120 had negative PBFC and BMA, 359 had positive PBFC and BMA, 3 had negative PBFC and positive BMA, and 3 had positive PBFC and negative BMA. There were small but significant differences in sensitivity (100 vs. 93.8%; P = 0.002) and positive predictive value (100 vs. 93.8%; P = 0.002) favoring BMA over PBFC among those demonstrating absence of circulating morphologic blasts. PBFC has high sensitivity and specificity for the diagnosis of childhood acute leukemia. The predictive value of PBFC remains high for patients without visible circulating blasts and may enhance the diagnostic process for determining the indications for marrow testing. © 2017 Wiley Periodicals, Inc.
The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.
Teppa, Roberto J; Roberts, James M
2005-01-01
Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.
Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz
2018-02-26
Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.
Armbrust, Laura J; Biller, David S; Bamford, Aubrey; Chun, Ruthanne; Garrett, Laura D; Sanderson, Michael W
2012-05-01
To compare the detection of pulmonary nodules by use of 3-view thoracic radiography and CT in dogs with confirmed neoplasia. Prospective case series. 33 dogs of various breeds. 3 interpreters independently evaluated 3-view thoracic radiography images. The location and size of pulmonary nodules were recorded. Computed tomographic scans of the thorax were obtained and evaluated by a single interpreter. The location, size, margin, internal architecture, and density of pulmonary nodules were recorded. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for thoracic radiography (with CT as the gold standard). 21 of 33 (64%) dogs had pulmonary nodules or masses detected on CT. Of the dogs that had positive CT findings, 17 of 21 (81%) had pulmonary nodules or masses detected on radiographs by at least 1 interpreter. Sensitivity of radiography ranged from 71% to 95%, and specificity ranged from 67% to 92%. Radiography had a positive predictive value of 83% to 94% and a negative predictive value of 65% to 89%. The 4 dogs that were negative for nodules on thoracic radiography but positive on CT were all large-breed to giant-breed dogs with osteosarcoma. CT was more sensitive than radiography for detection of pulmonary nodules. This was particularly evident in large-breed to giant-breed dogs. Thoracic CT is recommended in large-breed to giant-breed dogs with osteosarcoma if the detection of pulmonary nodules will change treatment.
Malama, Eleni; Hoffmann-Köhler, Peggy; Biedermann, Insa; Koopmann, Regine; Krücken, Jürgen; Molina, José Manuel; Moreno, Alvaro Martinez; von Samson-Himmelstjerna, Georg; Sotiraki, Smaragda; Demeler, Janina
2014-10-01
Teladorsagia circumcincta is among the most important gastrointestinal parasites in small ruminants and the predominant species in Southern European goats. Parasite control is largely based on metaphylactic/preventative treatments, which is often seen as non-sustainable anymore. The reasons are increased consumer demand to reduce chemicals in livestock production and anthelmintic resistance against the common drugs. This study aimed at the development of a T. circumcincta-enzyme-linked immunosorbent assay (ELISA) specifically for goats. Samples were obtained from goats raised parasite-free or infected experimentally. Sampling continued during the following pasture season and housing period. The sensitivity for the use in bulk milk samples as an indicator of T. circumcincta infection levels in grazing goats was examined. The ELISA enables clear differentiation of negative and positive animals. With a specificity of 100% negative cut-off values for serum and milk were 0.294 and 0.228 (sensitivity, 95%). Positive cut-off values (sensitivity, 90%) were 0.606 (serum) and 0.419 (milk), while a sensitivity of 95% resulted in 0.509 and 0.363, respectively. The grey-zone between negative/positive cut-offs was introduced to deal with animals in pre-patency and decreasing antibody levels after infection. There was no cross reactivity for Trichostrongylus colubriformis and Cooperia oncophora while for Haemonchus contortus and Fasciola hepatica it cannot be fully excluded currently. In bulk milk samples, 5% of the milk had to be contributed from animals infected with T. circumcincta to be detected as positive. The results derived from experimentally and naturally infected as well as parasite naïve animals indicate the potential of the ELISA to be used in targeted anthelmintic treatment regimes in goats.
Tiono, Alfred B; Ouédraogo, Alphonse; Diarra, Amidou; Coulibaly, Sam; Soulama, Issiaka; Konaté, Amadou T; Barry, Aïssata; Mukhopadhyay, Amitava; Sirima, Sodiomon B; Hamed, Kamal
2014-01-27
Rapid diagnostic tests (RDTs) are immune chromatographic tests targeting antigens of one or more Plasmodium species and offer the potential to extend accurate malaria diagnosis in endemic areas. In this study, the performance of Plasmodium falciparum-specific histidine-rich protein-2 (PfHRP-2) RDT in the detection of asymptomatic carriers from a hyperendemic region of Burkina Faso was compared with microscopy to gain further insight on its relevance in community-based interventions. The performance of HRP-2 test was evaluated in terms of sensitivity, specificity, positive and negative predictive values, discordant values, likelihood ratios, accuracy, and precision using microscopy as the 'gold standard'. This analysis was carried out in a controlled, parallel, cluster-randomized (18 clusters; 1:1) study in children and adults. The effect of systematic treatment of P. falciparum asymptomatic carriers during three consecutive monthly community screening campaigns on the incidence of symptomatic malaria episodes over a 12-month period was compared with no treatment of asymptomatic carriers. Sensitivity of HRP-2 test in asymptomatic carriers was higher in campaign 1 (92.4%) when compared to campaign 2 (84.0%) and campaign 3 (77.8%). The sensitivity of HRP-2 test increased as parasite density increased across all the age groups. Highest sensitivity (≥97.0%) was recorded at parasite densities of 1,000-4,999/μl, except for children aged 10 to 14 years. The specificity of HRP-2 test was comparable across age groups and highest in campaign 3 (95.9%). The negative predictive values were high across the three campaigns (≥92.7%) while the positive predictive values ranged from 23.2 to 73.8%. False-positive and false-negative rates were high in campaign 1 and campaign 3, respectively. The performance of HRP-2 test in detecting asymptomatic carriers of P. falciparum varied by age and parasite density. Although the use of HRP-2 test is beneficial for the diagnosis of acute malaria, its low sensitivity in screening asymptomatic carriers may limit its utility in pre-elimination interventional settings. The use of a practical and more sensitive test such as loop-mediated isothermal amplification in combination with a cost effective HRP-2 test may be worth exploring in such settings.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Eichenberger, Ramon Marc; Deplazes, Peter; Gabriël, Sarah
2017-09-15
Bovine cysticercosis (BCC), caused by the helminth Taenia saginata, is currently diagnosed solely by official meat inspection (MI) based on macroscopic detection of viable cysticerci or typical lesions of degenerated larvae. MI has a known low sensitivity (<16%), leading to a large proportion of infected cattle carcasses entering the human food chain and posing a risk to public health. Prevalence in Belgium based on MI results is estimated at around 0.22%. Due to the low sensitivity of MI, alternative techniques to detect BCC should be considered. This study evaluates MI, MI with additional incisions in the heart, specific antibody detection against excretory/secretory (E/S) in the Ab-ELISA and circulating antigens in the B158/B60 Ag-ELISA on 715 (101 MI-positive and 614 MI-negative) samples collected from carcasses at slaughterhouses in Belgium. Full dissection of the predilection sites was considered the reference test. During the study, mostly carcasses with (very) light infections were detected containing predominantly degenerated or calcified cysticerci and only few viable cysticerci. Dissection of the predilection sites detected 144 (23%) additional infections in the 614 MI-negative carcasses. When sequentially performing first the dissection of the predilection sites, followed by the Ag-ELISA and the Ab-ELISA, an additional 36% of MI-negative carcasses were found positive for BCC, resulting in a prevalence very much higher than the above mentioned 0.22%. The B158/B60 Ag-ELISA showed a sensitivity of 40% for the detection of carcasses containing viable cysticerci and a specificity of 100%, and detected 70 positive carcasses of which only 14 had been identified as positive during MI. If Ag-ELISA were implemented as a detection technique for BCC in the slaughterhouses, many infected carcasses would still not be detected due to the sensitivity of 40%. But as sensitivity increases with increasing number of cysticerci in the carcass, the infected carcasses passing inspection will be the ones containing only a few viable cysticerci and thus posing a smaller food safety problem. Ag-ELISA is preferred over the ES Ab-ELISA in this study, which had a sensitivity of 13.3% and a specificity of 91.7% in a population with overall low infection burdens. Copyright © 2017 Elsevier B.V. All rights reserved.
Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias
2016-05-20
To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.
Zavadovskaya, V D; Zorkal'tsev, M A; Udodov, V D; Zamyshevskaya, M A; Kilina, O Yu; Kurazhov, A P; Popov, K M
2015-01-01
To give the results of a software-based hybrid single photon emission computed tomography/magnetic resonance imaging (SPECT/MRI) in detecting osteomyelitis (OM) in patients with diabetic foot syndrome (DFS). Seventy-six patients (35 men and 41 women) (mean age, 59.4 +/- 7.1 years) with type 1 and 2 diabetes mellitus and suspected OM were examined. The investigation enrolled patients with neuropathic (n = 25), ischemic (n = 13), and mixed (n = 38) DFS. All the patients underwent (99m)Tc-HMPAO/ (99m)Tc-technefit labeled leukocyte scintigraphy; magnetic resonance imaging was performed in 30 patients. The results were combined using RView 9.06 software (Colin Studholme). Labeled leukocyte SPECT to Diagnose OM yielded 255 true positive (TP), 38 true negative (TN), 12 false negative (FP), and 1 false negative (FN) results. The accuracy of the technique was 82.9%. The FP results were due to the low resolution of the technique and to the small sizes of the object under study. One FN result was detected in a patient with ischemic DFS because of reduced blood flow. MRI to identify OM in patients with DFS provided 20 TP, 16 TN, 4 FP, and 2 FN results. Its diagnostic accuracy was 85.7%. The relative low specificity of MRI was associated with the presence of FP results due to the complexity of differential diagnosis of bone marrow edema and inflammatory infiltration. Assessing 42 hybrid SPECT/MR-images revealed 21 TP, 17 TN, 3 FP, and I FN results. The diagnostic accuracy was equal to 95.9%. Thus, comparing MRI (90.9% sensitivity and 80.0% specificity), labeled leukocyte scintigraphy (96.2% sensitivity and 76.0% specificity), and hybrid SPECT/MRI (95.5% sensitivity and 85.0% specificity) showed the high diagnostic efficiency of the latter.
Choe, Young June; Hu, Jae Kyung; Song, Kyung Min; Cho, Heeyeon; Yoon, Hee Sook; Kim, Seung Tae; Lee, Han Jung; Kim, Kisoon; Bae, Geun-Ryang; Lee, Jong-Koo
2012-01-01
In this study, we have described the clinical characteristics of vaccine-modified measles to assess the performance of an expanded case definition in a school outbreak that occurred in 2010. The sensitivity, specificity, and the positive and negative predictive values were evaluated. Among 74 cases of vaccine-modified measles, 47 (64%) met the original case definition. Fever and rash were observed in 73% (54/74); fever was the most common (96%, 71/74) presenting symptom, and rash was noted in 77% (57/74) of the cases. The original case definition showed an overall sensitivity of 63.5% and a specificity of 100.0%. The expanded case definition combining fever and rash showed a higher sensitivity (72.9%) but a lower specificity (88.2%) than the original. The presence of fever and one or more of cough, coryza, or conjunctivitis scored the highest sensitivity among the combinations of signs and symptoms (77.0%), but scored the lowest specificity (52.9%). The expanded case definition was sensitive in identifying suspected cases of vaccine-modified measles. We suggest using this expanded definition for outbreak investigation in a closed community, and consider further discussions on expanding the case definition of measles for routine surveillance in South Korea.
Detecting High Hyperopia: The Plus Lens Test and the Spot Vision Screener.
Feldman, Samuel; Peterseim, Mae Millicent W; Trivedi, Rupal H; Edward Wilson, M; Cheeseman, Edward W; Papa, Carrie E
2017-05-01
To evaluate the usefulness of the Plus Lens (Goodlite Company, Elgin, IL) test and the Spot Vision Screener (Welch Allyn, Skaneateles Falls, NY) in detecting high hyperopia in a pediatric population. Between June and August 2015, patients were screened with the Spot Vision Screener and the Plus Lens test prior to a scheduled pediatric ophthalmology visit. The following data were analyzed: demographic data, Plus Lens result, Spot Vision Screener result, cycloplegic refraction, and examination findings. Sensitivity/specificity and positive/negative predictive values were calculated for the Plus Lens test and Spot Vision Screener in detecting hyperopia as determined by the "gold-standard" cycloplegic refraction. A total of 109 children (average age: 82 months) were included. Compared to the ophthalmologist's cycloplegic refraction, the Spot Vision Screener sensitivity for +3.50 diopters (D) hyperopia was 31.25% and the specificity was 100%. The Plus Lens sensitivity for +3.50 D hyperopia was 43.75% and the specificity was 89.25%. Spot Vision Screener sensitivity increased with higher degrees of hyperopia. In this preliminary study, the Plus Lens test and the Spot Vision Screener demonstrated moderate sensitivity with good specificity in detecting high hyperopia. [J Pediatr Ophthalmol Strabismus. 2017;54(3):163-167.]. Copyright 2017, SLACK Incorporated.
Ojha, A R; Aryal, U R
2014-01-01
Urinary tract infection is a common problem in children and its early diagnosis and treatment is important to prevent long-term complications. Urine dipstick can be an important tool in this respect. The aim of this study is to look at the utility of urine dipstick as a diagnostic tool for UTI and will also see the clinical profile of children with UTI and sensitivity pattern of antibiotics among the isolates of urine culture. Urine samples of all children below 14 years of age who were suspected of urinary tract infection were sent for routine microscopic examination and dipstick testing. Urine culture and sensitivity were sent for those samples that were tested positive for nitrite, leucocyte esterase activity or both. For every fifth sample, which is dipstick negative, a culture and sensitivity testing was done. Among 110 children enrolled, 32(29%) cases had significant bacteriuria. Out of 32 culture positive cases 18(56%) were female. Fever was the main complaint (62.5%)). Escherichia Coli was isolated in 81.25% of cases. Amikacin was sensitive in 93% and amoxicillinwas resistant in 82%. The sensitivity, specificity, positive predictive value, negative predictive value of nitrite test was 65%, 80%, 58%, 85% respectively; those of leucocyte esterase are 84%, 55%, 43%, 89% respectively; those for significant microscopic pyuria >10/hpf were 65%, 74%, 51%, 84% respectively. E. Coli is the commonest uropathogen in children with UTI. Amikacin is the most sensitive antibiotic against all the isolates. A positive dipstick both for nitrite and leucocyte esterase is associated with high sensitivity and specificity for urinary tract infection as compared to either of them positive alone. In addition, urine WBC ≥10/hpf is associated with high probability of UTI.
Singh, Pramil N; Batech, Michael; Faed, Pegah; Jaceldo-Siegl, Karen; Martins, Marcia; Fraser, Gary E
2014-01-01
We studied Adventist Health Study 2 (AHS-2) cohort members to determine the reliability of long-term recall of adult dietary intake that occurred 33 years ago. Establishing the reliability of these measures supports studies of how dietary exposure across the life course affects risk of cancer and other noncommunicable disease outcomes. Among 1816 AHS-2 cohort members, we conducted a statistical comparison of long-term recall of meat, fish, dairy, and eggs at AHS-2 baseline with their report of current diet 33 years before AHS-2 baseline at an age of 30-60 years. Major findings are as follows: 1) a high correlation for frequency of red meat (R = 0.71), poultry (R = 0.67), and fish (R = 0.60); lower correlations for dairy (R = 0.19) and eggs (R = 0.28); 2) good concordance for dichotomous measures of red meat [sensitivity: 0.70; specificity: 0.92; positive predictive value (PPV): 0.91], poultry (sensitivity: 0.76; specificity: 0.87; PPV: 0.83), fish (sensitivity: 0.61; specificity: 0.93; PPV: 0.89), dairy (sensitivity: 0.95; specificity: 0.57; PPV: 0.99), and eggs (sensitivity: 0.95; specificity: 0.41; PPV: 0.96); negative predictive value for dairy and eggs was poor. Among older AHS-2 cohort members, we found good reliability of recall of red meat, poultry, and fish intake that occurred 33 years earlier.
Salotra, P; Sreenivas, G; Beena, K R; Mukherjee, A; Ramesh, V
2003-01-01
Aims: To evaluate the sensitivity and specificity of serological, immunohistochemical, and molecular methods in the diagnosis of post kala-azar dermal leishmaniasis (PKDL). Methods: Twenty five patients with confirmed PKDL and 25 controls were included in the study. G2D10, a monoclonal antibody against Leishmania, was used for the immunohistochemical (IHC) staining of lesion sections to visualise anti-Leishmania donovani antibodies. The diagnostic usefulness of IHC was compared with enzyme linked immunosorbent assay (ELISA) with a recombinant (rk39) antigen, and a species specific polymerase chain reaction (PCR) assay, amplifying a kinetoplast minicircle DNA sequence. Results: IHC detected 22 of 25 PKDL cases, giving a sensitivity of 88%. The diagnostic sensitivity of both the ELISA and PCR tests was higher (96%). All of the 25 controls examined were negative in PCR, indicating 100% specificity of the test, whereas ELISA showed 96% specificity. Conclusions: IHC with G2D10 significantly enhances the sensitivity of detection of PKDL over routine haematoxylin and eosin staining. ELISA with a recombinant antigen is an economical and practical assay. PCR is the most sensitive and specific diagnostic method for PKDL. The tests described would facilitate the recognition of patients with PKDL, enabling timely treatment, which would contribute greatly to the control of kala-azar. PMID:14600129
Delage Royle, Audrey; Balg, Frédéric; Bouliane, Martin J; Canet-Silvestri, Fanny; Garant-Saine, Laurianne; Sheps, David M; Lapner, Peter; Rouleau, Dominique M
2017-10-01
Quantifying glenohumeral bone loss is key in preoperative surgical planning for a successful Bankart repair. Simple radiographs can accurately measure bone defects in cases of recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A true anteroposterior (AP) view, alone and in combination with an axillary view, was used to evaluate the diagnostic properties of radiographs compared with computed tomography (CT) scan, the current gold standard, to predict significant bone defects in 70 patients. Sensitivity, specificity, and positive and negative predictive values were evaluated and compared. Detection of glenoid bone loss on plain film radiographs, with and without axillary view, had a sensitivity of 86% for both views and a specificity of 73% and 64% with and without the axillary view, respectively. For detection of humeral bone loss, the sensitivity was 8% and 17% and the specificity was 98% and 91% with and without the axillary view, respectively. Regular radiographs would have missed 1 instance of significant bone loss on the glenoid side and 20 on the humeral side. Interobserver reliabilities were moderate for glenoid detection (κ = 0.473-0.503) and poor for the humeral side (κ = 0.278-0.336). Regular radiographs showed suboptimal sensitivity, specificity, and reliability. Therefore, CT scan should be considered in the treatment algorithm for accurate quantification of bone loss to prevent high rates of recurrent instability.
Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.
Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A
2011-03-01
The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.
Nambi, S Gopal
2013-01-01
The most common instruments developed to assess the functional status of patients with Non specific low back pain is the Roland-Morris Disability Questionnaire (RMDQ). Clinical and epidemiological research related to low back pain in the Gujarati population would be facilitated by the availability of well-established outcome measures. To find the reliability, validity, sensitivity and specificity of the Gujarati version of the RMDQ for use in Non Specific Chronic low back pain. A reliability, validity, sensitivity and specificity study of Gujarati version of the Roland-Morris Disability Questionnaire (RMDQ). Thirty out patients with Non Specific Chronic low back pain were assessed by the RMDQ. Reliability is assessed by using internal consistency and the intra-class correlation coefficient (ICC). Internal construct validity is assessed by RASCH Analysis and external construct validity is assessed by association with pain and spinal movement. Clinical calculator was used to determine the sensitivity and specificity. Internal consistency of the RMDQ is found to be adequate (> 0.65) at both times, with high ICC's also at both time points. Internal construct validity of the scale is good, indicating a single underlying construct. Expected associations with pain and spinal movement confirm external construct validity. The Sensitivity and Specificity at cut off point of 0.5 was 80% and 84% with respectively positive predictive value (PPV) of 83.33% and negative predictive value (NPV) of 80.76%. The Questionnaire is at the ordinal level. The RMDQ is a one-dimensional, ordinal measure, which works well in the Gujarati population.
Humphreys, Kathryn L; Telzer, Eva H; Flannery, Jessica; Goff, Bonnie; Gabard-Durnam, Laurel; Gee, Dylan G; Lee, Steve S; Tottenham, Nim
2016-02-01
Decision making in the context of risk is a complex and dynamic process that changes across development. Here, we assessed the influence of sensitivity to negative feedback (e.g., loss) and learning on age-related changes in risky decision making, both of which show unique developmental trajectories. In the present study, we examined risky decision making in 216 individuals, ranging in age from 3-26 years, using the balloon emotional learning task (BELT), a computerized task in which participants pump up a series of virtual balloons to earn points, but risk balloon explosion on each trial, which results in no points. It is important to note that there were 3 balloon conditions, signified by different balloon colors, ranging from quick- to slow-to-explode, and participants could learn the color-condition pairings through task experience. Overall, we found age-related increases in pumps made and points earned. However, in the quick-to-explode condition, there was a nonlinear adolescent peak for points earned. Follow-up analyses indicated that this adolescent phenotype occurred at the developmental intersection of linear age-related increases in learning and decreases in sensitivity to negative feedback. Adolescence was marked by intermediate values on both these processes. These findings show that a combination of linearly changing processes can result in nonlinear changes in risky decision making, the adolescent-specific nature of which is associated with developmental improvements in learning and reduced sensitivity to negative feedback. (c) 2016 APA, all rights reserved).
Moore, William; Ripton-Snyder, Jennifer; Wu, George; Hendler, Craig
2011-06-01
The objective of this research was to determine the sensitivity and specificity of a commercially available computer-aided detection (CAD) system for detection of lung nodule on posterior-anterior (PA) chest radiograph in a varied patient population who are referred to computed tomographic angiogram (CTA) of the chest as a reference standard. Patients who had a PA chest radiograph with concomitant CTA of the chest were included in this retrospective study. The PA chest radiograph was analyzed by a CAD device, and results were recorded. A qualitative assessment of the CAD results was performed using a 5-point Likert scale. The CTA was then reviewed to determine if there were correlative nodules. The presence of a correlative nodule between 0.5 cm and 1.5 cm was considered a positive result. The baseline sensitivity of the system was determined to be 0.707 (95% CI = 0.52-0.86), with a specificity of 0.50 (95% CI = 0.38-0.76). Positive predictive value was 0.30 (95% CI = 0.24-0.49), with a negative predictive value of 0.858 (95% CI = 0.82-0.95), and accuracy of 0.555 (95% CI = 0.40-0.66). When excluding nodules that were qualitatively determined by a thoracic radiologist to be false positives, the specificity was 0.781 (95% CI = 0.764-0.839), the positive predictive value was 0.564 (95% CI = 0.491-0.654), the negative predictive value was 0.829 (95% CI = 0.819-0.878), and the accuracy was 0.737 (95% CI = 0.721-0.801). The use of CAD for lung nodule detection on chest radiograph, when used in conjunction with an experienced radiologist, has a very good sensitivity, specificity, and accuracy.
Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.
Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja
2016-11-01
High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.
[Functional endoscopic evaluation of swallowing in infants with deglutition disorders].
Partida-Justo, I; Israel Grijalva-Otero, J E; Ramírez-Figueroa, J L; Sepúlveda-Vildosola, A C; Zurita-Cruz, J N
2017-10-25
Functional endoscopic evaluation of swallowing (FEES) is a recognized method for Deglutition Disorders (DD) in adults, with anecdotal experience in children, obtaining not conclusive results. To compare the accuracy of test FEES in infants with high suspicion of altered DD seen in a third level hospital with the gold standard Videofluoroscopic (VF). The results and findings by FEES and VF of 66 children with clinical diagnosis of DD were compared. An estimate of the sensitivity and specificity of FEES was performed. As well as calculating positive predictive value (PPV), negative predictive value (NPV) and likelihood ratios. 60 patients enrolled, 4 and FEES showed high sensitivity to identify the presence of aspiration and penetration (9 98%) and high specificity for the arrest of spillage and waste (94% and 95%). Gastroesophageal reflux to make the diagnosis of DD with FEES had a sensitivity of 80% and specificity of 84%. Spill and penetration had the highest agreement with respect to the gold standard of 0.81. FEES in infants diagnosed with DD had a sensitivity of 80.8% and specificity 85.3%. 0696 concordance regarding to the VFD in the diagnosis of DD, and to identify suction stroke had a kappa of 0815.
Cavalcante, Danyelle Monteiro; de Oliveira, Maria Regina Fernandes; Rehem, Tânia Cristina Morais Santa Bárbara
2016-03-01
This study analyzes hospitalizations due to ambulatory care-sensitive conditions with a focus on infectious and parasitic diseases (IPDs) and validates the Hospital Information System, Brazilian Unified National Health System (SIH/SUS) for recording hospitalizations due to ambulatory care-sensitive conditions in a hospital in the Federal District, Brazil, in 2012. The study estimates the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the SIH for recording hospitalizations due to ambulatory care-sensitive conditions, with the patient's medical file as the gold standard. There were 1,604 hospitalizations for hospitalizations due to ambulatory care-sensitive conditions (19.6%, 95%CI: 18.7-20.5), and the leading IPDs were renal and urinary tract infection, infection of the skin and subcutaneous tissue, and infectious gastroenteritis. IPDs were the leading cause of hospitalization in the 20 to 29-year age bracket and caused 28 deaths. Sensitivity was 70.1% (95%CI: 60.5-79.7), specificity 88.4% (95%CI: 85.6-91.2), PPV = 51.7% (95%CI: 42.7-60.7), and NPV = 94.3% (95%CI: 92.2-96.4). The findings for admissions due to ACSCs in this hospital were similar to those of other studies, featuring admissions for IPDs. The SIH/SUS database was more specific than sensitive.
Yeo, Zhen Xuan; Wong, Joshua Chee Leong; Rozen, Steven G; Lee, Ann Siew Gek
2014-06-24
The Ion Torrent PGM is a popular benchtop sequencer that shows promise in replacing conventional Sanger sequencing as the gold standard for mutation detection. Despite the PGM's reported high accuracy in calling single nucleotide variations, it tends to generate many false positive calls in detecting insertions and deletions (indels), which may hinder its utility for clinical genetic testing. Recently, the proprietary analytical workflow for the Ion Torrent sequencer, Torrent Suite (TS), underwent a series of upgrades. We evaluated three major upgrades of TS by calling indels in the BRCA1 and BRCA2 genes. Our analysis revealed that false negative indels could be generated by TS under both default calling parameters and parameters adjusted for maximum sensitivity. However, indel calling with the same data using the open source variant callers, GATK and SAMtools showed that false negatives could be minimised with the use of appropriate bioinformatics analysis. Furthermore, we identified two variant calling measures, Quality-by-Depth (QD) and VARiation of the Width of gaps and inserts (VARW), which substantially reduced false positive indels, including non-homopolymer associated errors without compromising sensitivity. In our best case scenario that involved the TMAP aligner and SAMtools, we achieved 100% sensitivity, 99.99% specificity and 29% False Discovery Rate (FDR) in indel calling from all 23 samples, which is a good performance for mutation screening using PGM. New versions of TS, BWA and GATK have shown improvements in indel calling sensitivity and specificity over their older counterpart. However, the variant caller of TS exhibits a lower sensitivity than GATK and SAMtools. Our findings demonstrate that although indel calling from PGM sequences may appear to be noisy at first glance, proper computational indel calling analysis is able to maximize both the sensitivity and specificity at the single base level, paving the way for the usage of this technology for future clinical genetic testing.
Madžar, Zrinko; Kopljar, Mario; Madžar, Tomislav; Mesić, Marko; Mužina Mišić, Dubravka; Čiček, Slaven; Zovak, Mario
2016-12-01
The aim of the study was to assess diagnostic accuracy (sensitivity and specificity) of Fenyö-Lindberg and Teicher scores for distinguishing patients that need immediate surgical treatment from the others, in a female population from an urban setting. The study prospectively included 130 female patients admitted to the emergency department with abdominal pain indicating acute appendicitis. The scores and parameters of validity were calculated and compared to definitive diagnosis. For Fenyö-Lindberg score of -17 or less, 84.5% sensitivity, 55.6% specificity, 87.9% positive predictive value (PPV) and 48.4% negative predictive value (NPV) were recorded. For cut-off value greater or equal to -2, there was 59.2% sensitivity, 77.8% specificity, 91% PPV and 33.3% NPV. The Receiver Operating Characteristic (ROC) curve analysis of Fenyö-Lindberg score showed that the best single cut-off value for discriminating acute appendicitis in the study population was -15. For Teicher score, values greater than -3 yielded 89.3% sensitivity and 22.2% specificity, 81.4% PPV and 35.3% NPV. In conclusion, Fenyö-Lindberg score could be used as an additional tool to exclude appendicitis and avoid unnecessary appendectomies. Teicher score may help in recognizing patients with appendicitis. None of the two scores can indicate or decline appendectomy in all cases. Scoring systems may be useful for pointing to important clinical signs and symptoms in specific subpopulations.
Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J
2011-10-01
The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings that are missed on LD-PET/CT.
Kundnani, Vishal K; Zhu, Lisa; Tak, HH; Wong, HK
2010-01-01
Background: Multimodal intraoperative neuromonitoring is recommended during corrective spinal surgery, and has been widely used in surgery for spinal deformity with successful outcomes. Despite successful outcomes of corrective surgery due to increased safety of the patients with the usage of spinal cord monitoring in many large spine centers, this modality has not yet achieved widespread popularity. We report the analysis of prospectively collected intraoperative neurophysiological monitoring data of 354 consecutive patients undergoing corrective surgery for adolescent idiopathic scoliosis (AIS) to establish the efficacy of multimodal neuromonitoring and to evaluate comparative sensitivity and specificity. Materials and Methods: The study group consisted of 354 (female = 309; male = 45) patients undergoing spinal deformity corrective surgery between 2004 and 2008. Patients were monitored using electrophysiological methods including somatosensory-evoked potentials and motor-evoked potentials simultaneously. Results: Mean age of patients was 13.6 years (±2.3 years). The operative procedures involved were instrumented fusion of the thoracic/lumbar/both curves, Baseline somatosensory-evoked potentials (SSEP) and neurogenic motor-evoked potentials (NMEP) were recorded successfully in all cases. Thirteen cases expressed significant alert to prompt reversal of intervention. All these 13 cases with significant alert had detectable NMEP alerts, whereas significant SSEP alert was detected in 8 cases. Two patients awoke with new neurological deficit (0.56%) and had significant intraoperative SSEP + NMEP alerts. There were no false positives with SSEP (high specificity) but 5 patients with false negatives with SSEP (38%) reduced its sensitivity. There was no false negative with NMEP but 2 of 13 cases were false positive with NMEP (15%). The specificity of SSEP (100%) is higher than NMEP (96%); however, the sensitivity of NMEP (100%) is far better than SSEP (51%). Due to these results, the overall sensitivity, specificity and positive predictive value of combined multimodality neuromonitoring in this adult deformity series was 100, 98.5 and 85%, respectively. Conclusion: Neurogenic motor-evoked potential (NMEP) monitoring appears to be superior to conventional SSEP monitoring for identifying evolving spinal cord injury. Used in conjunction, the sensitivity and specificity of combined neuromonitoring may reach up to 100%. Multimodality monitoring with SSEP + NMEP should be the standard of care. PMID:20165679
Smith, M A; Dyson, S J; Murray, R C
2012-11-01
To determine the reliability of 2 magnetic resonance imaging (MRI) systems for detection of cartilage and bone lesions of the equine fetlock. To test the hypotheses that lesions in cartilage, subchondral and trabecular bone of the equine fetlock verified using histopathology can be detected on high- and low-field MR images with a low incidence of false positive or negative results; that low-field images are less reliable than high-field images for detection of cartilage lesions; and that combining results of interpretation from different pulse sequences increases detection of cartilage lesions. High- and low-field MRI was performed on 19 limbs from horses identified with fetlock lameness prior to euthanasia. Grading systems were used to score cartilage, subchondral and trabecular bone on MR images and histopathology. Sensitivity and specificity were calculated for images. High-field T2*-weighted gradient echo (T2*W-GRE) and low-field T2-weighted fast spin echo (T2W-FSE) images had high sensitivity but low specificity for detection of cartilage lesions. All pulse sequences had high sensitivity and low-moderate specificity for detection of subchondral bone lesions and moderate sensitivity and moderate-high specificity for detection of trabecular bone lesions (histopathology as gold standard). For detection of lesions of trabecular bone low-field T2*W-GRE images had higher sensitivity and specificity than T2W-FSE images. There is high likelihood of false positive results using high- or low-field MRI for detection of cartilage lesions and moderate-high likelihood of false positive results for detection of subchondral bone lesions compared with histopathology. Combining results of interpretation from different pulse sequences did not increase detection of cartilage lesions. MRI interpretation of trabecular bone was more reliable than cartilage or subchondral bone in both MR systems. Independent interpretation of a variety of pulse sequences may maximise detection of cartilage and bone lesions in the fetlock. Clinicians should be aware of potential false positive and negative results. © 2012 EVJ Ltd.
Moore, Erika M; Swerdlow, Steven H; Gibson, Sarah E
2017-10-01
Although most classical Hodgkin lymphomas (CHLs) are easily distinguished from nodular lymphocyte predominant Hodgkin lymphoma (NLPHL) and primary mediastinal large B-cell lymphoma (PMBL), cases with significant CD20 expression cause diagnostic confusion. Although the absence of OCT-2 and BOB.1 are useful in these circumstances, a variable proportion of CHLs are positive for these antigens. We investigated the utility of J chain and myocyte enhancer factor 2B (MEF2B) in the diagnosis of CHL; NLPHL; PMBL; T-cell/histiocyte-rich large B-cell lymphoma (TCRLBL); and B-cell lymphoma, unclassifiable, with features intermediate between diffuse large B-cell lymphoma and CHL, compared with OCT-2 and BOB.1. J chain and MEF2B highlighted lymphocyte predominant (LP) cells in 20/20 (100%) NLPHLs and were negative in 43/43 (100%) CHLs. Fourteen of 15 (93%) PMBLs and 4/4 (100%) TCRLBLs were MEF2B positive, whereas 67% of PMBLs and 50% of TCRLBLs were J chain positive. Three of 3 B-cell lymphomas, unclassifiable, with features intermediate between diffuse large B-cell lymphoma and CHL, were negative for J chain and MEF2B. J chain and MEF2B were 100% sensitive and specific for NLPHL versus CHL. MEF2B was 100% sensitive and 98% specific for PMBL versus CHL. Whereas loss of OCT-2 and/or BOB.1 expression had a sensitivity of only 86% and specificity of 100% for CHL versus NLPHL, PMBL, and TCRLBL, lack of both J chain and MEF2B expression was 100% sensitive and 97% specific. J chain and MEF2B are highly sensitive and specific markers of NLPHL versus CHL; are particularly useful in highlighting LP cells; and, with rare exception, are of greater utility than OCT-2 and BOB.1 in differentiating CHL from NLPHL and other large B-cell lymphomas. Copyright © 2017 Elsevier Inc. All rights reserved.
McCormick, Natalie; Lacaille, Diane; Bhole, Vidula; Avina-Zubieta, J. Antonio
2014-01-01
Objective Heart failure (HF) is an important covariate and outcome in studies of elderly populations and cardiovascular disease cohorts, among others. Administrative data is increasingly being used for long-term clinical research in these populations. We aimed to conduct the first systematic review and meta-analysis of studies reporting on the validity of diagnostic codes for identifying HF in administrative data. Methods MEDLINE and EMBASE were searched (inception to November 2010) for studies: (a) Using administrative data to identify HF; or (b) Evaluating the validity of HF codes in administrative data; and (c) Reporting validation statistics (sensitivity, specificity, positive predictive value [PPV], negative predictive value, or Kappa scores) for HF, or data sufficient for their calculation. Additional articles were located by hand search (up to February 2011) of original papers. Data were extracted by two independent reviewers; article quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. Using a random-effects model, pooled sensitivity and specificity values were produced, along with estimates of the positive (LR+) and negative (LR−) likelihood ratios, and diagnostic odds ratios (DOR = LR+/LR−) of HF codes. Results Nineteen studies published from1999–2009 were included in the qualitative review. Specificity was ≥95% in all studies and PPV was ≥87% in the majority, but sensitivity was lower (≥69% in ≥50% of studies). In a meta-analysis of the 11 studies reporting sensitivity and specificity values, the pooled sensitivity was 75.3% (95% CI: 74.7–75.9) and specificity was 96.8% (95% CI: 96.8–96.9). The pooled LR+ was 51.9 (20.5–131.6), the LR− was 0.27 (0.20–0.37), and the DOR was 186.5 (96.8–359.2). Conclusions While most HF diagnoses in administrative databases do correspond to true HF cases, about one-quarter of HF cases are not captured. The use of broader search parameters, along with laboratory and prescription medication data, may help identify more cases. PMID:25126761
Sum, Simon Siu-Man; Marcus, Andrea F; Blair, Debra; Olejnik, Laura A; Cao, Joyce; Parrott, J Scott; Peters, Emily N; Hand, Rosa K; Byham-Gray, Laura D
2017-09-01
To compare the 7-point subjective global assessment (SGA) and the protein energy wasting (PEW) score with nutrition evaluations conducted by registered dietitian nutritionists in identifying PEW risk in stage 5 chronic kidney disease patients on maintenance hemodialysis. This study is a secondary analysis of a cross-sectional study entitled "Development and Validation of a Predictive energy Equation in Hemodialysis". PEW risk identified by the 7-point SGA and the PEW score was compared against the nutrition evaluations conducted by registered dietitian nutritionists through data examination from the original study (reference standard). A total of 133 patients were included for the analysis. The sensitivity, specificity, positive and negative predictive value (PPV and NPV), positive and negative likelihood ratio (PLR and NLR) of both scoring tools were calculated when compared against the reference standard. The patients were predominately African American (n = 112, 84.2%), non-Hispanic (n = 101, 75.9%), and male (n = 80, 60.2%). Both the 7-point SGA (sensitivity = 78.6%, specificity = 59.1%, PPV = 33.9%, NPV = 91.2%, PLR = 1.9, and NLR = 0.4) and the PEW score (sensitivity = 100%, specificity = 28.6%, PPV = 27.2%, NPV = 100%, PLR = 1.4, and NLR = 0) were more sensitive than specific in identifying PEW risk. The 7-point SGA may miss 21.4% patients having PEW and falsely identify 40.9% of patients who do not have PEW. The PEW score can identify PEW risk in all patients, but 71.4% of patients identified may not have PEW risk. Both the 7-point SGA and the PEW score could identify PEW risk. The 7-point SGA was more specific, and the PEW score was more sensitive. Both scoring tools were found to be clinically confident in identifying patients who were actually not at PEW risk. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Malik, Muhammad Usman; Connelly, Tara M; Awan, Faisal; Pretorius, Frederik; Fiuza-Castineira, Constantino; El Faedy, Osama; Balfe, Paul
2017-04-01
The definitive diagnosis of acute appendicitis (AA) requires histopathological examination. Various clinical diagnostic scoring systems attempt to reduce negative appendectomy rates. The most commonly used in Western Europe and the USA is the Alvarado score. The Raja Isteri Pengiran Anak Saleha appendicitis (RIPASA) score achieves better sensitivity and specificity in Asian and Middle Eastern populations. We aimed to determine the diagnostic accuracy of the RIPASA score in Irish patients with AA. All patients who presented to our institution with right iliac fossa pain and clinically suspected AA between January 1 and December 31, 2015, were indentified from our hospital inpatient enquiry database and retrospectively studied. Operating theatre records and histology reports confirmed those who underwent a non-elective operative procedure and the presence or absence of AA. SPSS version 22 was used for statistical analysis. Standard deviation is provided where appropriate. Two hundred eight patients were included in the study (106/51% male, mean age 22.7 ± 9.2 years). One hundred thirty-five (64.9%) had histologically confirmed AA (mean symptom duration = 36.19 ± 15.90 h). At a score ≥7.5, the previously determined score most likely associated with AA in Eastern populations, the RIPASA scoring system demonstrated a sensitivity of 85.39%, specificity of 69.86%, positive predictive value of 84.06%, negative predictive value of 72.86% and diagnostic accuracy of 80% in our cohort. The RIPASA score is a useful tool to aid in the diagnosis of acute appendicitis in the Irish population. A score of ≥7.5 provides sensitivity and specificity exceeding that previously documented for the Alvarado score in Western populations. WHAT DOES THIS PAPER ADD TO THE LITERATURE?: This is the first study evaluating the utility of the RIPASA score in predicting acute appendicitis in a Western population. At a value of 7.5, a cut-off score suggestive of appendicitis in the Eastern population, RIPASA demonstrated a high-sensitivity, specificity, positive predictive value and diagnostic accuracy in our cohort and was more accurate than the commonly used Alvarado score.
Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection
Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.
2013-01-01
We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273
Machine Learning to Differentiate Between Positive and Negative Emotions Using Pupil Diameter
Babiker, Areej; Faye, Ibrahima; Prehn, Kristin; Malik, Aamir
2015-01-01
Pupil diameter (PD) has been suggested as a reliable parameter for identifying an individual’s emotional state. In this paper, we introduce a learning machine technique to detect and differentiate between positive and negative emotions. We presented 30 participants with positive and negative sound stimuli and recorded pupillary responses. The results showed a significant increase in pupil dilation during the processing of negative and positive sound stimuli with greater increase for negative stimuli. We also found a more sustained dilation for negative compared to positive stimuli at the end of the trial, which was utilized to differentiate between positive and negative emotions using a machine learning approach which gave an accuracy of 96.5% with sensitivity of 97.93% and specificity of 98%. The obtained results were validated using another dataset designed for a different study and which was recorded while 30 participants processed word pairs with positive and negative emotions. PMID:26733912
Brown, Teresa E; Crombie, Jane; Spurgin, Ann-Louise; Tripcony, Lee; Keller, Jacqui; Hughes, Brett G M; Dickie, Graeme; Kenny, Lizbeth Moira; Hodge, Robert A
2016-04-01
Swallowing and nutrition guidelines for patients with head and neck cancer are available for identification of proactive gastrostomy placement in patients with high nutritional risk. The purpose of this study was to investigate improvements to the validity of these guidelines. A multivariate analysis was fitted to the original dataset (n = 501) to examine the variables that may predict gastrostomy placement (eg, tumor site, treatment, sex, and age). Using these factors, the high risk category was modified and retrospectively validated in the same cohort to provide new measures of sensitivity and specificity. The following were positive predictors of gastrostomy placement: T3 (p = .01), T4 (p < .001), and chemoradiotherapy (p < .001). Laryngeal (p = .02) and skin cancer (p < .001) were negative predictors. Modification of the high risk definition improved sensitivity to 58% and maintained specificity at 92%. Minor modifications to the high risk definition in the guidelines have improved the guideline sensitivity for future use. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1163-E1171, 2016. © 2015 Wiley Periodicals, Inc.
Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.
Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu
2017-09-01
The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Guillot, Casey R; Pang, Raina D; Leventhal, Adam M
2014-01-01
Anxiety sensitivity--fear of anxiety symptoms--may increase motivation to smoke by influencing the development of cognitive expectations regarding smoking's negative reinforcing effects; yet, the nature and mechanisms of this pathway are unclear. We hypothesized that relations between anxiety sensitivity and negative reinforcement-related smoking expectancies would be mediated by negative urgency, that is, a trait tendency to act impulsively during negative affect. In a cross-sectional design, we administered self-report measures of anxiety sensitivity, negative urgency, and negative reinforcement-related smoking outcome and abstinence expectancies to 205 smokers (≥10 cigarettes/d, 34% female, M age = 44.4 years). Anxiety sensitivity was associated with stronger expectancies that smoking alleviates negative affect (β = 0.30; P < 0.0001) and smoking abstinence exacerbates aversive withdrawal symptoms (β = 0.24; P = 0.0004). Negative urgency partially mediated the relation between anxiety sensitivity and both types of negative reinforcement-related smoking expectancies (βs ≥ 0.057; Ps ≤ 0.007). Results remained significant after statistically controlling for anxiety and nicotine dependence symptoms. Smokers high in anxiety sensitivity tend to display negative urgency, which in turn is related to greater expectations of negative reinforcement consequences of smoking and smoking abstinence. Treatments that mitigate fear of anxiety symptoms and the tendency to act impulsively in response to negative affect (eg, interoceptive exposure, distress tolerance skills training, and mindfulness training) may be particularly useful in assisting with smoking cessation for high-anxiety sensitivity smokers.
Torlakovic, Emina E.; Francis, Glenn; Garratt, John; Gilks, Blake; Hyjek, Elizabeth; Ibrahim, Merdol; Miller, Rodney; Nielsen, Søren; Petcu, Eugen B.; Swanson, Paul E.; Taylor, Clive R.; Vyberg, Mogens
2014-01-01
Standardization of controls, both positive and negative controls, is needed for diagnostic immunohistochemistry (dIHC). The use of IHC-negative controls, irrespective of type, although well established, is not standardized. As such, the relevance and applicability of negative controls continues to challenge both pathologists and laboratory budgets. Despite the clear theoretical notion that appropriate controls serve to demonstrate the sensitivity and specificity of the dIHC test, it remains unclear which types of positive and negative controls are applicable and/or useful in day-to-day clinical practice. There is a perceived need to provide “best practice recommendations” for the use of negative controls. This perception is driven not only by logistics and cost issues, but also by increased pressure for accurate IHC testing, especially when IHC is performed for predictive markers, the number of which is rising as personalized medicine continues to develop. Herein, an international ad hoc expert panel reviews classification of negative controls relevant to clinical practice, proposes standard terminology for negative controls, considers the total evidence of IHC specificity that is available to pathologists, and develops a set of recommendations for the use of negative controls in dIHC based on “fit-for-use” principles. PMID:24714041
Hofmann-Thiel, Sabine; Molodtsov, Nikolay; Antonenka, Uladzimir; Hoffmann, Harald
2016-12-01
The Abbott RealTime MTB (RT MTB) assay is a new automated nucleic acid amplification test for the detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. In combination with the RealTime MTB INH/RIF (RT MTB INH/RIF) resistance assay, which can be applied to RT MTB-positive specimens as an add-on assay, the tests also indicate the genetic markers of resistance to isoniazid (INH) and rifampin (RIF). We aimed to evaluate the diagnostic sensitivity and specificity of RT MTB using different types of respiratory and extrapulmonary specimens and to compare performance characteristics directly with those of the FluoroType MTB assay. The resistance results obtained by RT MTB INH/RIF were compared to those from the GenoType MTBDRplus and from phenotypic drug susceptibility testing. A total of 715 clinical specimens were analyzed. Compared to culture, the overall sensitivity of RT MTB was 92.1%; the sensitivity rates for smear-positive and smear-negative samples were 100% and 76.2%, respectively. The sensitivities of smear-negative specimens were almost identical for respiratory (76.3%) and extrapulmonary (76%) specimens. Specificity rates were 100% and 95.8% for culture-negative specimens and those that grew nontuberculous mycobacteria, respectively. RT MTB INH/RIF was applied to 233 RT MTB-positive samples and identified resistance markers in 7.7% of samples. Agreement with phenotypic and genotypic drug susceptibility testing was 99.5%. In conclusion, RT MTB and RT MTB INH/RIF allow for the rapid and accurate diagnosis of tuberculosis (TB) in different types of specimens and reliably indicate resistance markers. The strengths of this system are the comparably high sensitivity with paucibacillary specimens, its ability to detect INH and RIF resistance, and its high-throughput capacities. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Splettstoesser, W.; Guglielmo-Viret, V.; Seibold, E.; Thullier, P.
2010-01-01
Tularemia is a highly contagious infectious zoonosis caused by the bacterial agent Francisella tularensis. Serology is still considered to be a cornerstone in tularemia diagnosis due to the low sensitivity of bacterial culture and the lack of standardization in PCR methodology for the direct identification of the pathogen. We developed a novel immunochromatographic test (ICT) to efficiently detect F. tularensis-specific antibodies in sera from humans and other mammalian species (nonhuman primate, pig, and rabbit). This new tool requires none or minimal laboratory equipment, and the results are obtained within 15 min. When compared to the method of microagglutination, which was shown to be more specific than the enzyme-linked immunosorbent assay, the ICT had a sensitivity of 98.3% (58 positive sera were tested) and a specificity of 96.5% (58 negative sera were tested) on human sera. On animal sera, the overall sensitivity was 100% (22 positive sera were tested) and specificity was also 100% (70 negative sera were tested). This rapid test preferentially detects IgG antibodies that may occur early in the course of human tularemia, but further evaluation with human sera is important to prove that the ICT can be a valuable field test to support a presumptive diagnosis of tularemia. The ICT can also be a useful tool to monitor successful vaccination with subunit vaccines or live vaccine strains containing lipopolysaccharide (e.g., LVS) and to detect seropositive individuals or animals in outbreak situations or in the context of epidemiologic surveillance programs in areas of endemicity as recently recommended by the World Health Organization. PMID:20220165
Ma, C; Wang, X; Shao, M; Zhao, L; Jiawei, X; Wu, Z; Wang, H
2015-06-01
Aim of the present study was to investigate the usefulness of 18F-FDG SPECT/CT in differentiated thyroid cancer (DTC) with elevated serum thyroglobulin (Tg) but negative iodine-131 scan. This retrospective review of patients with DTC recurrence who had 18F-FDG SPECT/CT and 18F-FDG PET/CT for elevated serum Tg but negative iodine-131 scan (March 2007-October 2012). After total thyroidectomy followed by radioiodine ablation, 86 consecutive patients with elevated Tg levels underwent 18F-FDG SPECT/CT or 18F-FDG PET/CT. Of these, 45 patients had 18F-FDG SPECT/CT, the other 41 patients had 18F-FDG PET/CT 3-4weeks after thyroid hormone withdrawal. The results of 18F-FDG PET/CT and SPECT/CT were correlated with patient follow-up information, which included the results from subsequent imaging modalities such as neck ultrasound, MRI and CT, Tg levels, and histologic examination of surgical specimens. The diagnostic accuracy of the two imaging modalities was evaluated. In 18F-FDG SPECT/CT scans, 24 (24/45) patients had positive findings, 22 true positive in 24 patients, false positive in 2 patients, true-negative and false-negative in 6, 15 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG SPECT/CT were 59.5%, 75% and 62.2%, respectively. Twenty six patients had positive findings on 18F-FDG PET/CT scans, 23 true positive in 26 (26/41) patients, false positive in 3 patients, true-negative and false-negative in 9, 6 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 79.3%, 81.8% and 78.1%, respectively. Clinical management changed for 13 (29%) of 45 patients by 18F-FDG SPECT/CT, 14 (34%) of 41 patients by 18F-FDG PET/CT including surgery, radiation therapy, or multikinase inhibitor. Based on the retrospective analysis of 86 patients, 18F-FDG SPECT/CT has lower sensitivity in the diagnosis of DTC recurrence with elevated Tg and negative iodine-131scan to 18F-FDG PET/CT. The clinical application of FDG SPECT/CT is then limited and cannot replace PET/CT.
2011-01-01
Introduction The objective of this study was to determine the ability of various parameters commonly used for the diagnosis of acute meningitis to differentiate between bacterial and viral meningitis, in adult patients with a negative direct cerebrospinal fluid (CSF) examination. Methods This was a prospective study, started in 1997, including all patients admitted to the emergency unit with acute meningitis and a negative direct CSF examination. Serum and CSF samples were taken immediately on admission. The patients were divided into two groups according to the type of meningitis: bacterial (BM; group I) or viral (VM; group II). The CSF parameters investigated were cytology, protein, glucose, and lactate; the serum parameters evaluated were C-reactive protein and procalcitonin. CSF/serum glucose and lactate ratios were also assessed. Results Of the 254 patients with meningitis with a negative direct CSF examination, 35 had BM and 181, VM. The most highly discriminative parameters for the differential diagnosis of BM proved to be CSF lactate, with a sensitivity of 94%, a specificity of 92%, a negative predictive value of 99%, a positive predictive value of 82% at a diagnostic cut-off level of 3.8 mmol/L (area under the curve (AUC), 0.96; 95% confidence interval (CI), 0.95 to 1), and serum procalcitonin, with a sensitivity of 95%, a specificity of 100%, a negative predictive value of 100%, and a positive predictive value of 97% at a diagnostic cut-off level of 0.28 ng/ml (AUC, 0.99; 95% CI, 0.99 to 1). Conclusions Serum procalcitonin and CSF lactate concentrations appear to be the most highly discriminative parameters for the differential diagnosis of BM and VM. PMID:21645387
2017-07-07
RESEARCH ARTICLE Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub...America * judith.harbertson.ctr@mail.mil Abstract HIV rapid diagnostic tests (RDTs) combined in an algorithm are the current standard for HIV diagnosis...in many sub-Saharan African countries, and extensive laboratory testing has con- firmed HIV RDTs have excellent sensitivity and specificity. However
Asimos, Andrew W; Ward, Shana; Brice, Jane H; Rosamond, Wayne D; Goldstein, Larry B; Studnek, Jonathan
2014-11-01
Emergency medical services (EMS) protocols, which route patients with suspected stroke to stroke centers, rely on the use of accurate stroke screening criteria. Our goal is to conduct a statewide EMS agency evaluation of the accuracies of the Cincinnati Prehospital Stroke Scale (CPSS) and the Los Angeles Prehospital Stroke Screen (LAPSS) for identifying acute stroke patients. We conducted a retrospective study in North Carolina by linking a statewide EMS database to a hospital database, using validated deterministic matching. We compared EMS CPSS or LAPSS results (positive or negative) to the emergency department diagnosis International Classification of Diseases, Ninth Revision codes. We calculated sensitivity, specificity, and positive and negative likelihood ratios for the EMS diagnosis of stroke, using each screening tool. We included 1,217 CPSS patients and 1,225 LAPSS patients evaluated by 117 EMS agencies from 94 North Carolina counties. Most EMS agencies contributing data had high annual patient volumes and were governmental agencies with nonvolunteer, emergency medical technician-paramedic service level providers. The CPSS had a sensitivity of 80% (95% confidence interval [CI] 77% to 83%) versus 74% (95% CI 71% to 77%) for the LAPSS. Each had a specificity of 48% (CPSS 95% CI 44% to 52%; LAPSS 95% CI 43% to 53%). The CPSS and LAPSS had similar test characteristics, with each having only limited specificity. Development of stroke screening scales that optimize both sensitivity and specificity is required if these are to be used to determine transport diversion to acute stroke centers. Copyright © 2014. Published by Elsevier Inc.
Kinori, Michael; Molina, Iliana; Hernandez, Eric O; Robbins, Shira L; Granet, David B; Coleman, Anne L; Brown, Stuart I
2018-05-01
To compare the performance of the PlusoptiX S12 mobile photoscreener and the Retinomax K+3 Autorefractor as screening devices in preschool children. Children ranging from 3 to 5 years of age from 11 San Diego County preschools underwent vision screening in their schools where ambient light could not always be controlled using both the Retinomax and the PlusoptiX. Cycloplegic refraction on the consented children was subsequently performed on the UCSD EyeMobile for children on-site at the school locations. A total of 321 children were screened with the PlusoptiX and Retinomax. The PlusoptiX referred 22% of children, of whom 70% of the referrals were read as "unable". The Retinomax referred 13% and there were no "unables". Similar results occurred in the cycloplegic-refracted 182 consented children-64% of the PlusoptiX referrals were read as "unable" . Only one third of these "unables" required glasses. Both devices referred the four children with amblyopia and one case of strabismus. However, PlusoptiX's 3 false negatives had amblyopia risk factors (ARFs) while the one Retinomax's false negative did not have ARFs. The Retinomax screening had 95% sensitivity and 94% specificity. The PlusoptiX screening had 86% sensitivity and 84% specificity. In this preschool population and environment, the PlusoptiX referred 63% more than the Retinomax in addition to a lower specificity and sensitivity. Adjusting PlusoptiX referral criteria might not substantially improve the specificity of the PlusoptiX due to the high numbers of "unables".
Child–Pugh Versus MELD Score for the Assessment of Prognosis in Liver Cirrhosis
Peng, Ying; Qi, Xingshun; Guo, Xiaozhong
2016-01-01
Abstract Child–Pugh and MELD scores have been widely used for the assessment of prognosis in liver cirrhosis. A systematic review and meta-analysis aimed to compare the discriminative ability of Child–Pugh versus MELD score to assess the prognosis of cirrhotic patients. PubMed and EMBASE databases were searched. The statistical results were summarized from every individual study. The summary areas under receiver operating characteristic curves, sensitivities, specificities, positive and negative likelihood ratios, and diagnostic odds ratios were also calculated. Of the 1095 papers initially identified, 119 were eligible for the systematic review. Study population was heterogeneous among studies. They included 269 comparisons, of which 44 favored MELD score, 16 favored Child–Pugh score, 99 did not find any significant difference between them, and 110 did not report the statistical significance. Forty-two papers were further included in the meta-analysis. In patients with acute-on-chronic liver failure, Child–Pugh score had a higher sensitivity and a lower specificity than MELD score. In patients admitted to ICU, MELD score had a smaller negative likelihood ratio and a higher sensitivity than Child–Pugh score. In patients undergoing surgery, Child–Pugh score had a higher specificity than MELD score. In other subgroup analyses, Child–Pugh and MELD scores had statistically similar discriminative abilities or could not be compared due to the presence of significant diagnostic threshold effects. Although Child–Pugh and MELD scores had similar prognostic values in most of cases, their benefits might be heterogeneous in some specific conditions. The indications for Child–Pugh and MELD scores should be further identified. PMID:26937922
Gram staining for the treatment of peritonsillar abscess.
Takenaka, Yukinori; Takeda, Kazuya; Yoshii, Tadashi; Hashimoto, Michiko; Inohara, Hidenori
2012-01-01
Objective. To examine whether Gram staining can influence the choice of antibiotic for the treatment of peritonsillar abscess. Methods. Between 2005 and 2009, a total of 57 cases of peritonsillar abscess were analyzed with regard to cultured bacteria and Gram staining. Results. Only aerobes were cultured in 16% of cases, and only anaerobes were cultured in 51% of cases. Mixed growth of aerobes and anaerobes was observed in 21% of cases. The cultured bacteria were mainly aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. Phagocytosis of bacteria on Gram staining was observed in 9 cases. The bacteria cultured from these cases were aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. The sensitivity of Gram staining for the Gram-positive cocci and Gram-negative rods was 90% and 64%, respectively. The specificity of Gram staining for the Gram-positive cocci and Gram-negative rods was 62% and 76%, respectively. Most of the Gram-positive cocci were sensitive to penicillin, but some of anaerobic Gram-negative rods were resistant to penicillin. Conclusion. When Gram staining shows only Gram-positive cocci, penicillin is the treatment of choice. In other cases, antibiotics effective for the penicillin-resistant organisms should be used.
Quirino, Isabel G; Silva, Jose Maria P; Diniz, Jose S; Lima, Eleonora M; Rocha, Ana Cristina S; Simões e Silva, Ana Cristina; Oliveira, Eduardo A
2011-01-01
The aim of this study was to evaluate the diagnostic accuracy of dimercapto-succinic acid renal scintigraphy and renal ultrasound in identifying high grade vesicoureteral reflux in children after a first episode of urinary tract infection. A total of 533 children following a first urinary tract infection were included in the analysis. Patients were assessed by 3 diagnostic imaging studies, renal ultrasound, dimercapto-succinic acid scan and voiding cystourethrography. The main event of interest was the presence of high grade (III to V) vesicoureteral reflux. The combined and separate diagnostic accuracy of screening methods was assessed by calculation of diagnostic OR, sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratio. A total of 246 patients had reflux, of whom 144 (27%) had high grade (III to V) disease. Sensitivity, negative predictive value and diagnostic OR of ultrasound for high grade reflux were 83.3%, 90.8% and 7.9, respectively. Dimercapto-succinic acid scan had the same sensitivity as ultrasound but a higher negative predictive value (91.7%) and diagnostic OR (10.9). If both tests were analyzed in parallel by using the OR rule, ie a negative diagnosis was established only when both test results were normal, sensitivity increased to 97%, negative predictive value to 97% and diagnostic OR to 25.3. Only 9 children (6.3%) with dilating reflux had an absence of alterations in both tests. Our findings support the idea that ultrasound and dimercapto-succinic acid scan used in combination are reliable predictors of dilating vesicoureteral reflux. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Usefulness of component resolved analysis of cat allergy in routine clinical practice.
Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz
2016-01-01
Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future studies may facilitate a better understanding of its use and subsequently may improve the clinical management of allergic patients.
Daft, Barbara M; Barr, Bradd C; Gardner, Ian A; Read, Deryck; Bell, William; Peyser, Karen G; Ardans, Alex; Kinde, Hailu; Morrow, Jennifer K
2002-10-01
To determine sensitivity and specificity of western blot testing (WBT) of CSF and serum for diagnosis of equine protozoal myeloencephalitis (EPM) in horses with and without neurologic abnormalities. Prospective investigation. 65 horses with and 169 horses without neurologic abnormalities. CSF and serum from horses submitted for necropsy were tested for Sarcocystis neurona-specific antibody with a WBT. Results of postmortem examination were used as the gold standard against which results of the WBT were compared. Sensitivity of WBT of CSF was 87% for horses with and 88% for horses without neurologic abnormalities. Specificity of WBT of CSF was 44% for horses with and 60% for horses without neurologic abnormalities. Regardless of whether horses did or did not have neurologic abnormalities, sensitivity and specificity of WBT of serum were not significantly different from values for WBT of CSF. Ninety-four horses without EPM had histologic evidence of slight CNS inflammation. The low specificity of WBT of CSF indicated that it is inappropriate to diagnose EPM on the basis of a positive test result alone because of the possibility of false-positive test results. The high sensitivity, however, means that a negative result is useful in ruling out EPM. There was no advantage in testing CSF versus serum in horses without neurologic abnormalities. Slight CNS inflammation was common in horses with and without S neurona-specific antibodies in the CSF and should not be considered an indication of CNS infection with S neurona.
[Comparison of the Arthroscopic Finding in the Knee Joint and the MRI - Retrospective Study].
Šimeček, K; Látal, P; Duda, J; Šimeček, M
2017-01-01
PURPOSE OF THE STUDY Our retrospective study presents the comparison of the preoperative magnetic resonance imaging of the knee joint - MRI - and the arthroscopic finding - ASC. Its aim is to find out how a positive or a negative finding of MRI corresponds with the operative finding and how much the experience of radiologist contributes to the conformity. MATERIAL AND METHODS The MRI findings of knee joints treated surgically at two departments in 2013 and 2014 were assessed. The MRI was performed in a total of 470 patients who subsequently underwent an arthroscopic surgery. A conformity or a non-conformity in anterior, posterior horn and complete rupture of both menisci and in partial or complete tear of anterior cruciate ligament - LCA was searched for. The sensitivity, specificity and accuracy of MRI were established. The difference between experienced and less experienced radiologists was evaluated. The analysis of the radiology report, surgical protocol of ASC and medical history in the documentation was performed. The cartilage was not subject to evaluation. The finding of Grade 1 meniscus tear on MRI was evaluated as negative. Grade 2 and Grade 3 were evaluated as positive. RESULTS Comparison of the preoperative MRI and the arthroscopic finding 1. The group with MRI reported 3 % of diagnostic arthroscopies. The control group without MRI (551 ASC) reported 15 % diagnostic arthroscopies. 2. Low sensitivity of MRI (0.67) in negative findings of ASC. It concerned 7 cases in which a pathological finding was identified on a MRI scan, but not by ASC. In two cases the repeated arthroscopy confirmed that a pathology inside the knee joint was overlooked by the arthroscopist. In the remaining five cases, the clinical finding improved without a repeated surgery. 3. High sensitivity of MRI is shown in the most frequent finding - posterior horn of medial meniscus (0.94). 4. Lower sensitivity (0.76) in partial and (0.83) in complete ACL tear. It increases to 0.93 if partial and complete tear are put together. Both MRI and ASC detect the pathology of ligament, but do not agree in terms of terminology. 5. Lower sensitivity (0.78) was seen in posterior horn of lateral meniscus, most likely due to its complicated anatomy. 6. Specificity of complete tear of medial meniscus tear is 0.99. Lower specificity in the posterior horn of medial meniscus (0.81) shows a higher number of positive MRI findings in negative ASC findings. Some posterior horn tear can be overlooked by an inexperienced surgeon. The MRD findings need to be studied. 7. High specificity (0.99) was described in negative findings. In three cases only, the surgeon discovered a pathological finding, not revealed by MRI scan. It always concerned a tear within the posterior horn of the medial meniscus. 8. Specificity (0.88, 0.93 or 0.86, respectively) in partial, complete and all ACL damages in total. 9. We concluded that contributing to the degree of agreement between MRI and ASC is also the experience of a radiologist. The most experienced radiologist evaluated 190 of 470 MRI scans, the remaining twelve radiologists assessed 280 scans. The posterior horn of the medial meniscus - sensitivity or specificity evaluated by an experienced radiologist (0.98 and 0.88, respectively) and inexperienced radiologist (0.91 and 0.79). The specificity and sensitivity in complete ACL tears - by experienced radiologist (0.91 and 0.94, respectively) and inexperienced radiologist (0.81 and 0.90, respectively). The test accuracy of the experienced radiologist in evaluating the most frequent injuries of soft knee structures was by 9-10 % higher than of the inexperienced radiologist. DISCUSSION The results obtained by the other authors show that the sensitivity and specificity range from 0.6 to 0.9. They agree that the MRI is unsuitable for assessing the cartilage. We confirm that the results are worse when evaluating the posterior horn of the lateral meniscus. We have also proven that the radiologist s experience does play an important role. It can be the reason for a high degree of difference between the results of various authors. Some of them give preference to a clinical examination or a diagnostic arthroscopy instead of the MRI. At our department, MRI is indicated if we are convinced it can help with the indication or where it will suggest what to focus on during the surgery. CONCLUSIONS A preoperative MRI scan can prevent an unnecessary arthroscopy. It displays structures to the surgeon which shall be reviewed in detail during the surgery. We recommend paying attention to Grade 2 MRI findings, positive MRI findings on the posterior horn of medial meniscus and to MRI findings on partial ACL tears. Such menisci and ligaments shall be carefully reviewed. Clinical preoperative examination and cooperation between the surgeon, the "arthroscopist", and the radiologist is essential. The experience of the radiologist also plays a role when evaluating the MRI scan. We have introduced MRI ward rounds. Key words: MRI, knee joint, knee arthroscopy, sensitivity, specificity, accuracy.
Evaluation of FASTPlaqueTB to diagnose smear-negative tuberculosis in a peripheral clinic in Kenya.
Bonnet, M; Gagnidze, L; Varaine, F; Ramsay, A; Githui, W; Guerin, P J
2009-09-01
To evaluate the performance and feasibility of FASTPlaqueTB in smear-negative tuberculosis (TB) suspects in a peripheral clinic after laboratory upgrading. Patients with cough > or=2 weeks, two sputum smear-negative results, no response to 1 week of amoxicillin and abnormal chest X-ray were defined as smear-negative suspects. One sputum sample was collected, decontaminated and divided into two: half was tested with FASTPlaqueTB in the clinic laboratory and the other half was cultured on Löwenstein-Jensen medium in the Kenyan Medical Research Institute. Test sensitivity and specificity were evaluated in all patients and in human immunodeficiency virus (HIV) infected patients. Feasibility was assessed by the contamination rate and the resources required to upgrade the laboratory. Of 208 patients included in the study, 56.2% were HIV-infected. Of 203 FASTPlaqueTB tests, 95 (46.8%) were contaminated, which interfered with result interpretation and led to the interruption of the study. Sensitivity and specificity were respectively 31.2% (95%CI 12.1-58.5) and 94.9% (95%CI 86.8-98.4) in all patients and 33.3% (95%CI 9.9-65.1) and 93.9% (95%CI 83.1-98.7) in HIV-infected patients. Upgrading the laboratory cost euro 20,000. FASTPlaqueTB did not perform satisfactorily in this setting. If contamination can be reduced, in addition to laboratory upgrading, its introduction in peripheral clinics would require further assessment in smear-negative and HIV co-infected patients and test adaptation for friendlier use.
Inequality across Consonantal Contrasts in Speech Perception: Evidence from Mismatch Negativity
ERIC Educational Resources Information Center
Cornell, Sonia A.; Lahiri, Aditi; Eulitz, Carsten
2013-01-01
The precise structure of speech sound representations is still a matter of debate. In the present neurobiological study, we compared predictions about differential sensitivity to speech contrasts between models that assume full specification of all phonological information in the mental lexicon with those assuming sparse representations (only…
An Unbiased Estimate of Global Interrater Agreement
ERIC Educational Resources Information Center
Cousineau, Denis; Laurencelle, Louis
2017-01-01
Assessing global interrater agreement is difficult as most published indices are affected by the presence of mixtures of agreements and disagreements. A previously proposed method was shown to be specifically sensitive to global agreement, excluding mixtures, but also negatively biased. Here, we propose two alternatives in an attempt to find what…
Data transformation methods for multiplexed assays
Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J
2013-07-23
Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.
Castro-Almarales, Raúl Lázaro; Álvarez-Castelló, Mirta; Ronquillo-Díaz, Mercedes; Rodríguez-Canosa, José S; González-León, Mayda; Navarro-Viltre, Bárbara I; Betancourt-Mesia, Daniel; Enríquez-Domínguez, Irene; Reyes-Zamora, Mary Carmen; Oliva-Díaz, Yunia; Mateo-Morejón, Maytee; Labrada-Rosado, Alexis
2016-01-01
Diagnostic options for immune reactions to mosquito bites are limited. In Cuba, IgE-mediated reactions are frequently related to Culex quinquefasciatus bite. To determine the sensitivity and specificity of skin prick test with two doses of standardized extract in nitrogen protein units (PNU of Culex quinquefasciatus (BIOCEN, Cuba). An analytical study was conducted on 100 children between 2 and 15 years old. Fifty atopic patients with a history of allergy to mosquito bite and positive specific serum IgE Culex quinquefasciatus and fifty atopic patients without a history of allergy to mosquito bite and negative specific serum IgE to Culex quinquefasciatus. Skin prick tests (SPT) were performed by duplicates on the forearms of the patients. Investigated doses were 100 PNU/mL and 10 PNU/mL. SPT with the highest concentration obtained a mean wheal size of 22.09 mm2 and for lower doses of 8.09 mm2, a statistically significant difference (p=0.001, Student's t test). Positive skin test correlated in 100% of patients with the presence of specific IgE. Testing with both doses showed a 94% of specificity and 88% of sensitivity. The diagnostic accuracy of SPT using both doses of standardized extract was similar, which justifies its use for diagnosis of sensitization to Culex quinquefasciatus in patients with symptoms of allergy to mosquito bite.
Tate, Jacqueline E; Patel, Manish M; Cortese, Margaret M; Payne, Daniel C; Lopman, Benjamin A; Yen, Catherine; Parashar, Umesh D
2016-05-01
Case-control studies are often performed to estimate postlicensure vaccine effectiveness (VE), but the enrollment of controls can be challenging, time-consuming, and costly. We evaluated whether children enrolled in the same hospital-based diarrheal surveillance used to identify rotavirus cases but who test negative for rotavirus (test-negative controls) can be considered a suitable alternative to nondiarrheal hospital or community-based control groups (traditional controls). We compared calculated VE estimates as a function of varying values of true VE, attack rates of rotavirus and nonrotavirus diarrhea in the population, and sensitivity and specificity of the rotavirus enzyme immunoasssay. We also searched the literature to identify rotavirus VE studies that used traditional and test-negative control groups and compared VE estimates obtained using the different control groups. Assuming a 1% attack rate for severe rotavirus diarrhea, a 3% attack rate for severe nonrotavirus diarrhea in the population, a test sensitivity of 96%, and a specificity of 100%, the calculated VE estimates using both the traditional and test-negative control groups closely approximated the true VE for all values from 30% to 100%. As true VE decreased, the traditional case-control approach slightly overestimated the true VE and the test-negative case-control approach slightly underestimated this estimate, but the absolute difference was only ±0.2 percentage points. Field VE estimates from 10 evaluations that used both traditional and test-negative control groups were similar regardless of control group used. The use of rotavirus test-negative controls offers an efficient and cost-effective approach to estimating rotavirus VE through case-control studies. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Wang, Karyn L; Groth, Markus
2014-03-01
The impact of emotional labor on customer outcomes is gaining considerable attention in the literature, with research suggesting that the authenticity of emotional displays may positively impact customer outcomes. However, research investigating the impact of more inauthentic emotions on service delivery outcomes is mixed (see Chi, Grandey, Diamond, & Krimmel, 2011). This study explores 2 potential reasons for why the service outcomes of inauthentic emotions are largely inconsistent: the impact of distinct surface acting strategies and the role of service delivery context. Drawing on social-functional theories of emotions, we surveyed 243 dyads of employees and customers from a wide variety of services to examine the links between employee surface acting and customer service satisfaction, and whether this relationship is moderated by relationship strength and service personalization. Our findings suggest that faking positive emotions has no bearing on service satisfaction, but suppressing negative emotions interacts with contextual factors to predict customers' service satisfaction, in line with social-functional theories of emotions. Specifically, customers who know the employee well are less sensitive to the negative effects of suppressed negative emotions, and customers in highly personalized service encounters are more sensitive to the negative effects of suppressed negative emotions. We conclude with a discussion of theoretical and practical implications.
Mason, Tyler B; Maduro, Ralitsa S; Derlega, Valerian J; Hacker, Desi S; Winstead, Barbara A; Haywood, Jacqueline E
2017-04-01
This research focused on how race-based rejection sensitivity (RS-Race) and components of racial identity intensify negative psychological reactions to an incident of vicarious racism. We examined how these individual difference variables directly and/or indirectly predicted African American students' reactions to the trial of George Zimmerman in the killing of the African American teenager, Trayvon Martin. In Study 1, 471 African American students completed measures of RS-Race, thought intrusions about the Zimmerman trial, and outcome variables (negative affect about the Zimmerman trial and forgiveness for Mr. Zimmerman). In Study 2, 304 African American students completed measures of racial identity (centrality, private regard, and public regard), thought intrusions about the Zimmerman trial, negative affect, and forgiveness. In Study 1, higher RS-Race was either directly and/or indirectly (via thought intrusions) related to more negative affect and lower forgiveness. In Study 2, high racial centrality and low public regard either directly and/or indirectly (via thought intrusions) predicted more negative affect and lower forgiveness. RS-Race and specific components of racial identity are likely to sensitize African Americans to incidents of racism that happen to other African Americans, leading to negative psychological reactions when these events occur. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Savilahti, Erkki
2008-01-01
The role of early infant nutrition in the development of allergic symptoms and allergic sensitization has been disputed for 70 years. Interaction between genetic factors and infant feeding has been limited to studies on parental heredity of allergy and length of breastfeeding, as well as the qualities of breast milk. In the 10 original studies comparing the development of allergic symptoms among children in whom breastfeeding duration was used as a risk factor separately among those with either positive or negative parental heredity for atopy, no definite answer could be found. The effect of early feeding was even changed in both heredity negative and positive groups when looking at symptoms at ages 2 and 5 years. Of 9 possible combinations, 6 were present in the studies, and none in more than 2 studies. For sensitization, long breastfeeding was a risk in 3 of 5 reports if the family history of allergy was positive, and in 2 if negative. Low levels of soluble CD14 and cow's milk-specific IgA antibodies in breast milk may increase an infant's risk of developing allergy.
Zimmer-Gembeck, Melanie J; Nesdale, Drew
2013-02-01
Rejection sensitivity (RS) is a tendency to expect, perceive, and overreact to rejection. Our objective was to examine whether anxious and angry RS have specific associations with negative social reactions, and whether responses are intensified in situations of high rejection ambiguity. In two studies, youth (N = 464 and N = 371) reported their RS and anticipated responses to social scenarios. In Study 1, all scenarios portrayed overt rejection events. In Study 2, participants were randomly assigned to conditions portraying overt or ambiguous rejection. Greater rejection expectation was associated with more negative reactions to rejection. Moreover, as expected, anxiety about rejection was uniquely associated with withdrawal, and anger about rejection was uniquely associated with retribution (i.e., reactive aggression). In the second study, RS persons responded more negatively than others to both overt and high ambiguous rejections, but retribution was intensified among participants high in rejection expectation when rejection was ambiguous, and withdrawal was intensified among participants high in anxious RS in overt rejection situations. Consistent with the revised RS model, there are different patterns of emotions, cognitions, and behaviors in response to high and low ambiguous rejection events, which are heightened in youth sensitive to rejection. © 2012, Wiley Periodicals, Inc.
Murata, Fernando Henrique Antunes; Ferreira, Marina Neves; Pereira-Chioccola, Vera Lucia; Spegiorin, Lígia Cosentino Junqueira Franco; Meira-Strejevitch, Cristina da Silva; Gava, Ricardo; Silveira-Carvalho, Aparecida Perpétuo; de Mattos, Luiz Carlos; Brandão de Mattos, Cinara Cássia
2017-09-01
Toxoplasmosis during pregnancy can have severe consequences. The use of sensitive and specific serological and molecular methods is extremely important for the correct diagnosis of the disease. We compared the ELISA and ELFA serological methods, conventional PCR (cPCR), Nested PCR and quantitative PCR (qPCR) in the diagnosis of Toxoplasma gondii infection in pregnant women without clinical suspicion of toxoplasmosis (G1=94) and with clinical suspicion of toxoplasmosis (G2=53). The results were compared using the Kappa index, and the sensitivity, specificity, positive predictive value and negative predictive value were calculated. The results of the serological methods showed concordance between the ELISA and ELFA methods even though ELFA identified more positive cases than ELISA. Molecular methods were discrepant with cPCR using B22/23 primers having greater sensitivity and lower specificity compared to the other molecular methods. Copyright © 2017 Elsevier Inc. All rights reserved.
Physical Employment Standards for UK Firefighters
Stevenson, Richard D.M.; Siddall, Andrew G.; Turner, Philip F.J.; Bilzon, James L.J.
2017-01-01
Objective: The aim of this study was to assess sensitivity and specificity of surrogate physical ability tests as predictors of criterion firefighting task performance and to identify corresponding minimum muscular strength and endurance standards. Methods: Fifty-one (26 male; 25 female) participants completed three criterion tasks (ladder lift, ladder lower, ladder extension) and three corresponding surrogate tests [one-repetition maximum (1RM) seated shoulder press; 1RM seated rope pull-down; repeated 28 kg seated rope pull-down]. Surrogate test standards were calculated that best identified individuals who passed (sensitivity; true positives) and failed (specificity; true negatives) criterion tasks. Results: Best sensitivity/specificity achieved were 1.00/1.00 for a 35 kg seated shoulder press, 0.79/0.92 for a 60 kg rope pull-down, and 0.83/0.93 for 23 repetitions of the 28 kg rope pull-down. Conclusions: These standards represent performance on surrogate tests commensurate with minimum acceptable performance of essential strength-based occupational tasks in UK firefighters. PMID:28045801