Sample records for sensitivity tests show

  1. Amoxicillin rash in patients with infectious mononucleosis: evidence of true drug sensitization.

    PubMed

    Ónodi-Nagy, Katinka; Kinyó, Ágnes; Meszes, Angéla; Garaczi, Edina; Kemény, Lajos; Bata-Csörgő, Zsuzsanna

    2015-01-01

    It hasn't been clearly understood yet whether sensitization to antibiotics, the virus itself or transient loss of drug tolerance due to the virus, is responsible for the development of maculopapular exanthems following amoxicillin intake in patients with infectious mononucleosis. We aimed to examine whether sensitization to penicillin developed among patients with skin rash following amoxicillin treatment within infectious mononucleosis. Ten patients were investigated for drug sensitization by lymphocyte transformation test and six patients were further tested by prick-, intradermal and patch tests employing the penicillin's main antigens. Lymphocyte transformation test showed negative results with amoxicillin, while one patient had positive reaction to cefixime. Six patients with suspected sensitization to amoxicillin were then investigated by in vivo tests. Prick tests were negative in all six patients, but the intradermal tests showed positive reactions in four patients. Our data demonstrate that in vitro testing is not sensitive enough in determining drug sensitization to penicillin. In vivo tests should be performed to detect sensitization and indeed with skin tests our results confirmed that sensitization to aminopenicillin may develop within infectious mononucleosis.

  2. Impact sensitivity of materials in contact with liquid and gaseous oxygen at high pressure

    NASA Technical Reports Server (NTRS)

    Schwinghamer, R. J.

    1972-01-01

    As a result of the Apollo 13 incident, increased emphasis is being placed on materials compatibility in a high pressure GOX environment. It is known that in addition to impact sensitivity of materials, approximately adiabatic compression conditions can contrive to induce materials reactivity. Test runs at high pressure using the ABMA tester indicate the following: (1) The materials used in the tests showed an inverse relationship between thickness and impact sensitivity. (2) Several materials tested exhibited greater impact sensitivity in GOX than in LOX. (3) The impact sensitivity of the materials tested in GOX, at the pressures tested, showed enhanced impact sensitivity with higher pressure. (4) The rank ordering of the materials tested in LOX up to 1000 psia is the same as the rank ordering resulting from tests in LOX at 14.7 psia.

  3. Accuracy of Rapid Fecal Calprotectin Test in Monitoring Inflammatory Bowel Diseases Under Treatment with TNFα Antagonists.

    PubMed

    Tursi, Antonio; Elisei, Walter; Picchio, Marcello; Giorgetti, GianMarco; Brandimarte, Giovanni

    2015-05-01

    Anti-TNFα antibodies are effective in treating inflammatory bowel diseases (IBDs) unresponsive to the standard treatments. Information about the role of rapid fecal calprotectin (FC) in monitoring ambulatory IBD patients under treatment with anti-TNFα is lacking. Our aim was to assess the accuracy of rapid FC in monitoring those patients. Seventy-two patients (38 males, 34 females, mean age 42.5 years, range 23-57 years), affected by ulcerative colitis (UC) (20 patients) or by Crohn's disease (CD) (52 patients) were treated with anti-TNFα antibodies. FC was assessed by a rapid semiquantitative test. With respect to the absence of clinical remission, FC test showed sensitivity of 71.8 %, specificity of 65.2 %, PPV of 41.8 %, and NPV of 86.9 %. In UC patients, FC test showed a sensitivity of 66.7 %, a specificity of 56.1 %, a PPV of 18.2 %, and a NPV of 92.0 %. In CD patients, FC test showed sensitivity of 70.6 %, specificity of 65.2 %, PPV of 50.0 %, and NPV of 81.8 %. With respect to the presence of endoscopic lesions, FC test showed sensitivity of 73.5 %, specificity of 96.0 %, PPV of 96.2 %, and NPV of 72.7 %. In UC patients, FC test showed sensitivity of 47.2 %, specificity of 84.6 %, PPV of 89.5 %, and NPV of 36.7 %. In CD patients, FC test showed sensitivity of 90.1 %, specificity of 79.7 %, PPV of 71.9 %, and NPV of 93.3 %. Diagnostic accuracy of rapid FC seems better in predicting persistence of endoscopic lesions than clinical remission in IBD patients under treatment with anti-TNFα.

  4. Spatial contrast sensitivity - Effects of age, test-retest, and psychophysical method

    NASA Technical Reports Server (NTRS)

    Higgins, Kent E.; Jaffe, Myles J.; Caruso, Rafael C.; Demonasterio, Francisco M.

    1988-01-01

    Two different psychophysical methods were used to test the spatial contrast sensitivity in normal subjects from five age groups. The method of adjustment showed a decline in sensitivity with increasing age at all spatial frequencies, while the forced-choice procedure showed an age-related decline predominantly at high spatial frequencies. It is suggested that a neural component is responsible for this decline.

  5. Evaluation of the bioNexia Legionella Test, Including Impact of Incubation Time Extension, for Detection of Legionella pneumophila Serogroup 1 Antigen in Urine.

    PubMed

    Badoux, Paul; Euser, Sjoerd M; Bruin, Jacob P; Mulder, Patrick P G; Yzerman, Ed P F

    2017-06-01

    In this study, we compared the bioNexia test (bioMérieux, Marcy-l'Étoile, France), a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 in urine, with the BinaxNOW urinary antigen test (Alere, Waltham, Massachusetts, USA). After 15 min of incubation (in accordance with the manufacturers' instructions), the sensitivities and specificities were, respectively, 76.5% and 97.2% for the bioNexia test and 87.1% and 100% for the BinaxNOW test. After a prolonged incubation time of 60 min, the sensitivities and specificities increased to, respectively, 89.4% and 97.2% for the bioNexia test and 91.8% and 100% for the BinaxNOW test. When the tests were read after 15 min, the concentration of discrepant urine samples increased the sensitivities to 94.1% for both tests. In conclusion, we found that although the bioNexia test showed lower sensitivity for the detection of L. pneumophila antigen in nonconcentrated urine compared to the BinaxNOW test, a prolonged incubation time as well as the use of concentrated samples showed comparable sensitivities for both tests. Copyright © 2017 American Society for Microbiology.

  6. Evaluation of phenotypic detection methods for metallo-β-lactamases (MBLs) in clinical isolates of Pseudomonas aeruginosa.

    PubMed

    Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M

    2014-07-01

    Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.

  7. The sensitivity and specificity of thermometry and plethysmography in the assessment of hand-arm vibration syndrome.

    PubMed

    Thompson, Aaron; House, Ron; Manno, Michael

    2008-05-01

    Finger plethysmography and thermometry are objective measures used to assess the vascular aspect of hand-arm vibration syndrome (HAVS). Research to date shows poor correlation between these tests and Stockholm Workshop Scale (SWS) vascular stage. Clinicians, researchers and compensation boards require objective means to diagnose and quantify HAVS. To define the specificity and sensitivity of thermometry and plethysmography using the SWS as the reference criterion. A secondary goal was to consider cut points for the tests optimizing sensitivity and specificity. A cross-sectional analysis was conducted on HAVS patients seen at an occupational medicine specialty clinic. Plethysmography and thermometry were analyzed using SWS vascular stage as the outcome variable. Logistic regression controlled for age, smoking and time since last vibration exposure and use of vasoactive medications. The sensitivity and specificity of the combined tests were calculated using varying cut points. A total of 139 patients consented to participate in the study. Plethysmography stage 1 or greater showed the highest sensitivity (sensitivity 94% and specificity 15%). Specificity was optimized combining plethysmography stage 3 and thermometry stage 3 (specificity 98% and sensitivity 23%). Maximal diagnostic accuracy was achieved by plethysmography alone setting the criteria for a positive test as being stage 1 or greater (70%). Neither plethysmography nor thermometry either alone or in combination demonstrated sufficient sensitivity and specificity to serve as an objective correlate for SWS vascular stage. All combinations of plethysmography and thermometry showed a lower specificity than sensitivity indicating that the SWS may be less sensitive in detecting vascular pathology than the objective tests.

  8. The role of oncogenic human papillomavirus determination for diagnosis of high-grade anal intraepithelial neoplasia in HIV-infected MSM.

    PubMed

    Burgos, Joaquin; Hernández-Losa, Javier; Landolfi, Stefania; Guelar, Ana; Dinares, MªCarmen; Villar, Judith; Navarro, Jordi; Ribera, Esteve; Falcó, Vicenç; Curran, Adria

    2017-10-23

    To assess the oncogenic human papillomavirus (HPV) determination and the cotesting HPV and anal cytology value to detect high-grade anal intraepithelial neoplasia (HGAIN) in a cohort of HIV-MSM. Prospective study of HIV-infected MSM who underwent screening for anal dysplasia. Screening program includes anal cytology, HPV testing, and high-resolution anoscopy (HRA) at each visit. Histological samples were obtained if suspicious lesions were revealed by HRA. Sensitivity and specificity of the different tests were calculated by using histological results of HRA-guided biopsy as the reference test for HGAIN diagnosis. From May 2009 to August 2016, 692 HIV-infected MSM underwent 1827 anal cytologies, 1841 HRA examinations, and 1607 HPV testing. At first screening visit, anal cytology results were abnormal in 418 (60.4%) of 692 patients, and oncogenic HPV genotypes were found in 482 (79.5%) of 606 patients. Anal cytology showed a sensitivity of 89.2% [95% confidence interval (CI); 80.7-94.2] and a specificity of 44.2% (95% CI; 40.2-48.2) to detect HGAIN. Oncogenic HPV testing had 90.4% sensitivity (95% CI; 82-86.8) and 24.4% specificity (95% CI; 20.8-28.3). Cotesting showed a 97.4% sensitivity (95% CI; 91-99.3) and 14% specificity (95% CI; 11.2-17.3). In patients with atypical squamous cells of uncertain significance on cytology, oncogenic HPV testing had 91.3% sensitivity and 28.3% specificity to detect HGAIN. Abnormal cytology and oncogenic HPV determination showed similar sensitivity for detecting HGAIN. The two tests used together improved the sensitivity but with lowered specificity. In our opinion, HPV testing does not improve HGAIN detection and should not replace anal cytology as a standard screening test for HIV-infected MSM.

  9. Data mining methods in the prediction of Dementia: A real-data comparison of the accuracy, sensitivity and specificity of linear discriminant analysis, logistic regression, neural networks, support vector machines, classification trees and random forests

    PubMed Central

    2011-01-01

    Background Dementia and cognitive impairment associated with aging are a major medical and social concern. Neuropsychological testing is a key element in the diagnostic procedures of Mild Cognitive Impairment (MCI), but has presently a limited value in the prediction of progression to dementia. We advance the hypothesis that newer statistical classification methods derived from data mining and machine learning methods like Neural Networks, Support Vector Machines and Random Forests can improve accuracy, sensitivity and specificity of predictions obtained from neuropsychological testing. Seven non parametric classifiers derived from data mining methods (Multilayer Perceptrons Neural Networks, Radial Basis Function Neural Networks, Support Vector Machines, CART, CHAID and QUEST Classification Trees and Random Forests) were compared to three traditional classifiers (Linear Discriminant Analysis, Quadratic Discriminant Analysis and Logistic Regression) in terms of overall classification accuracy, specificity, sensitivity, Area under the ROC curve and Press'Q. Model predictors were 10 neuropsychological tests currently used in the diagnosis of dementia. Statistical distributions of classification parameters obtained from a 5-fold cross-validation were compared using the Friedman's nonparametric test. Results Press' Q test showed that all classifiers performed better than chance alone (p < 0.05). Support Vector Machines showed the larger overall classification accuracy (Median (Me) = 0.76) an area under the ROC (Me = 0.90). However this method showed high specificity (Me = 1.0) but low sensitivity (Me = 0.3). Random Forest ranked second in overall accuracy (Me = 0.73) with high area under the ROC (Me = 0.73) specificity (Me = 0.73) and sensitivity (Me = 0.64). Linear Discriminant Analysis also showed acceptable overall accuracy (Me = 0.66), with acceptable area under the ROC (Me = 0.72) specificity (Me = 0.66) and sensitivity (Me = 0.64). The remaining classifiers showed overall classification accuracy above a median value of 0.63, but for most sensitivity was around or even lower than a median value of 0.5. Conclusions When taking into account sensitivity, specificity and overall classification accuracy Random Forests and Linear Discriminant analysis rank first among all the classifiers tested in prediction of dementia using several neuropsychological tests. These methods may be used to improve accuracy, sensitivity and specificity of Dementia predictions from neuropsychological testing. PMID:21849043

  10. Differential effects of context on psychomotor sensitization to ethanol and cocaine.

    PubMed

    Didone, Vincent; Quoilin, Caroline; Dieupart, Julie; Tirelli, Ezio; Quertemont, Etienne

    2016-04-01

    Repeated drug injections lead to sensitization of their stimulant effects in mice, a phenomenon sometimes referred to as drug psychomotor sensitization. Previous studies showed that sensitization to cocaine is context dependent as its expression is reduced in an environment that was not paired with cocaine administration. In contrast, the effects of the test context on ethanol sensitization remain unclear. In the present study, female OF1 mice were repeatedly injected with 1.5 g/kg ethanol to test for both the effects of context novelty/familiarity and association on ethanol sensitization. A first group of mice was extensively pre-exposed to the test context before ethanol sensitization and ethanol injections were paired with the test context (familiar and paired group). A second group was not pre-exposed to the test context, but ethanol injections were paired with the test context (nonfamiliar and paired group). Finally, a third group of mice was not pre-exposed to the test context and ethanol was repeatedly injected in the home cage (unpaired group). Control groups were similarly exposed to the test context, but were injected with saline. In a second experiment, cocaine was used as a positive control. The same behavioral procedure was used, except that mice were injected with 10 mg/kg cocaine instead of ethanol. The results show a differential involvement of the test context in the sensitization to ethanol and cocaine. Cocaine sensitization is strongly context dependent and is not expressed in the unpaired group. In contrast, the expression of ethanol sensitization is independent of the context in which it was administered, but is strongly affected by the relative novelty/familiarity of the environment. Extensive pre-exposure to the test context prevented the expression of ethanol sensitization. One possible explanation is that expression of ethanol sensitization requires an arousing environment.

  11. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  12. The sensitivity and reproducibility of the zebrafish (Danio rerio) embryo test for the screening of waste water quality and for testing the toxicity of chemicals.

    PubMed

    Lahnsteiner, Franz

    2008-07-01

    The sensitivity of the zebrafish embryo test, a test proposed for routine waste water control, was compared with the acute fish toxicity test, in the determination of six types of waste water and ten different chemicals. The waste water was sampled from the following industrial processes: paper and cardboard production, hide tanning, metal galvanisation, carcass treatment and utilisation, and sewage treatment. The chemicals tested were: dimethylacetamide, dimethylsulphoxide, cadmium chloride, cyclohexane, hydroquinone, mercuric chloride, nickel chloride, nonylphenol, resmethrin and sodium nitrite. For many of the test substances, the zebrafish embryo test and the acute fish toxicity test results showed high correlations. However, there were certain environmentally-relevant substances for which the results of the zebrafish embryo test and the acute fish toxicity test differed significantly, up to 10,000-fold (Hg(2+) > 150-fold difference; NO(2)(-) > 300-fold; Cd(2+) > 200-fold; resmethrin > 10,000-fold). For the investigated waste water samples and chemicals, the survival rate of the zebrafish embryos showed high variations between different egg samples, within the range of the EC50 concentration. Subsequently, 5-6 parallel assays were deemed to be the appropriate number necessary for the precise evaluation of the toxicity of the test substances. Also, it was found that the sensitivities of different ontogenetic stages to chemical exposure differed greatly. During the first 12 hours after fertilisation (4-cell stage to the 5-somite stage), the embryos reacted most sensitively to test substance exposure, whereas the later ontogenetic stages showed only slight or no response, indicating that the test is most sensitive during the first 24 hours post-fertilisation.

  13. Quantitative relationship between the local lymph node assay and human skin sensitization assays.

    PubMed

    Schneider, K; Akkan, Z

    2004-06-01

    The local lymph node assay (LLNA) is a new test method which allows for the quantitative assessment of sensitizing potency in the mouse. Here, we investigate the quantitative correlation between results from the LLNA and two human sensitization tests--specifically, human repeat insult patch tests (HRIPTs) and human maximization tests (HMTs). Data for 57 substances were evaluated, of which 46 showed skin sensitizing properties in human tests, whereas 11 yielded negative results in humans. For better comparability data from mouse and human tests were transformed to applied doses per skin area, which ranged over four orders of magnitude for the substances considered. Regression analysis for the 46 human sensitizing substances revealed a significant positive correlation between the LLNA and human tests. The correlation was better between LLNA and HRIPT data (n=23; r=0.77) than between LLNA and HMT data (n=38; r=0.65). The observed scattering of data points is related to various uncertainties, in part associated with insufficiencies of data from older HMT studies. Predominantly negative results in the LLNA for another 11 substances which showed no skin sensitizing activity in human maximization tests further corroborate the correspondence between LLNA and human tests. Based on this analysis, the LLNA can be considered a reliable basis for relative potency assessments for skin sensitizers. Proposals are made for the regulatory exploitation of the LLNA: four potency groups can be established, and assignment of substances to these groups according to the outcome of the LLNA can be used to characterize skin sensitizing potency in substance-specific assessments. Moreover, based on these potency groups, a more adequate consideration of sensitizing substances in preparations becomes possible. It is proposed to replace the current single concentration limit for skin sensitizers in preparations, which leads to an all or nothing classification of a preparation as sensitizing to skin ("R43") in the European Union, by differentiated concentration limits derived from the limits for the four potency groups.

  14. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    PubMed

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an estimate of the potency sub-category of a skin sensitizer as well, but these approaches need further independent evaluation with a new dataset of chemicals. To conclude, this update shows that the field of non-animal approaches for skin sensitization has evolved greatly in recent years and that it is possible to predict skin sensitization hazard without animal testing.

  15. [Neuropsychological modifications at high altitude: from Pamir to Karakorum].

    PubMed

    Nardi, Bernardo; Brandoni, Marco; Capecci, Ilaria; Castellani, Simona; Rupoli, Sara; Bellantuono, Cesario

    2009-01-01

    Neuropsychological modifications and acclimatization processes at over 8000 without auxiliary oxygen were investigated in two climbers, evaluating attentive abilities and matching their performances. During rest in base-camp (4800 m), at other three Resorts - Resort I (5800 m), Resort II (6400 m), Resort III (7200 m) -, and four months after the return at low altitude, were administered: Temporal Orientation Test (TOT), Trail Making Test (TMT), Animal Naming (AN), Verbal Fluency Test (VFT), Arithmetical Judgment Test (AJT), and Drawing Test (DT). Results. At TOT and at AJT, both the climbers demonstrated scores at higher normal levels (Eq = 4) in all the Resorts in which they were performed. They showed an impairment at AN test, especially at Resort III, showing sensitivity of animal naming to hypoxia. At the DT, human figures were reduced in their dimensions and details, as consequence of the tendency to self closure and introversion that occurs at higher altitudes. Neuropsychological functions concerning verbal fluency showed sensitivity to hypoxia, especially at higher altitudes. TMT demonstrated that attentive ability can be preserved if acclimatization is good. Sensitivity to hypoxia and acclimatization processes showed a significant subjective variability. The results of this study show that exposure to high altitude produces some significant neuropsychological changes.

  16. The Clinical Impact of Bet v 6 in Birch Pollen-Sensitized Patients.

    PubMed

    Gellrich, Donata; Eder, Katharina; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2017-01-01

    Bet v 6, a minor birch pollen allergen, is commercially available for allergen-specific IgE antibody testing. However, there is hardly any literature on the clinical impact of Bet v 6. The aim of the present study was to analyze if testing specific IgE against Bet v 6 can add valuable benefit to the standard diagnostics of birch pollen-sensitized patients, especially in patients with unknown sensitization-eliciting allergens. Birch pollen-sensitized patients with missing IgE reactivity against Bet v 1, 2, and 4 were tested for specific IgE antibodies against Bet v 6. For comparison, an equal number of randomly selected patients with birch pollen sensitization, regardless of their individual sensitization patterns, were tested for specific anti-Bet v 6. Of 57 cases with missing reactivity against the standard birch pollen allergens, 2 patients were positive for Bet v 6. In the representative sample, 3 patients showed specific IgE against Bet v 6 - resulting in a total prevalence of 5%. None of the Bet v 6-positive patients showed allergic symptoms after exposure to birch pollen or an oral allergy syndrome. An increased prevalence of asthma and a higher degree of sensitization were the only distinctive clinical features in Bet v 6-positive patients. Among birch pollen-sensitized patients, the prevalence of specific IgE against Bet v 6 is low. Further, sensitization to Bet v 6, which shows characteristics of a panallergen, remains clinically silent. Therefore, determination of anti-Bet v 6 is not considered useful in the clinical routine. © 2017 S. Karger AG, Basel.

  17. Assessment of methicillin resistant Staphylococcus Aureus detection methods: analytical comparative study.

    PubMed

    Ibrahim, Omer Mohammed Ali; Bilal, Naser Eldin; Osman, Omran Fadl; Magzoub, Magzoub Abbas

    2017-01-01

    The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains were isolated and identified by conventional methods, and then confirmed by PCR detection of coagulase gene. PCR detection of mecA gene was used as a gold standard to assess oxacillin resistance screen agar base (ORSAB), oxacillin disc, cefoxitin disc (at different temperatures and incubation periods) and MRSA-latex agglutination test. S.aureus ATCC 25923 was used as control. Sensitivity and specificity were calculated. MRSA- latex agglutination was the most accurate test; it showed 100% of both sensitivity and specificity, followed by cefoxitin disc with sensitivity of 98.48% and specificity of 100%. However, both of oxacillin disc and oxacillin resistance screen agar base showed less accurate results, and were affected by incubation periods. Oxacillin disc after 24 h incubation both at 30°C and 35°C showed sensitivity and specificity values of 87.88% and 96.23%, respectively. However, after 48h incubation the test at 30°C showed sensitivity and specificity values of 89.39%, and 94.34%, respectively. At 35°C (48h) it showed values of 89.39%, 92.45% respectively. Specificity of ORSAB was more than oxacillin disc at 35°C after 24h incubation 98.11% and 96.23%, respectively. MRSA- latex agglutination and cefoxitin disc diffusion tests are recommended for routine detection of MRSA.

  18. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  19. Test-retest reliability of infant event related potentials evoked by faces.

    PubMed

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Exploratory rearing: a context- and stress-sensitive behavior recorded in the open-field test.

    PubMed

    Sturman, Oliver; Germain, Pierre-Luc; Bohacek, Johannes

    2018-02-16

    Stressful experiences are linked to anxiety disorders in humans. Similar effects are observed in rodent models, where anxiety is often measured in classic conflict tests such as the open-field test. Spontaneous rearing behavior, in which rodents stand on their hind legs to explore, can also be observed in this test yet is often ignored. We define two forms of rearing, supported rearing (in which the animal rears against the walls of the arena) and unsupported rearing (in which the animal rears without contacting the walls of the arena). Using an automated open-field test, we show that both rearing behaviors appear to be strongly context dependent and show clear sex differences, with females rearing less than males. We show that unsupported rearing is sensitive to acute stress, and is reduced under more averse testing conditions. Repeated testing and handling procedures lead to changes in several parameters over varying test sessions, yet unsupported rearing appears to be rather stable within a given animal. Rearing behaviors could therefore provide an additional measure of anxiety in rodents relevant for behavioral studies, as they appear to be highly sensitive to context and may be used in repeated testing designs.

  1. ISOLATION OF RABBIT IGA ANTIHAPTEN ANTIBODY AND DEMONSTRATION OF SKIN-SENSITIZING ACTIVITY IN HOMOLOGOUS SKIN

    PubMed Central

    Onoue, Kaoru; Yagi, Yasuo; Pressman, David

    1966-01-01

    Multiple antibody components of rabbit antisera against p-azobenzenearsonate (Rp) were studied with respect to their globulin nature and skin-sensitizing activity. IgA antibody was characterized by isolating two IgA-rich fractions from a specifically purified antibody preparation. Examination of these fractions showed that IgA antibodies existed in two molecular forms, one with a sedimentation constant of 7S and the other 9S. Skin-sensitizing activity was examined by a P-K type test and a PCA test with Rp-rabbit serum albumin in homologous (rabbit) species. Only the 7S but not 9S IgA antibody sensitized rabbit skin. IgM antibody showed no activity and IgG antibody showed very low activity. In contrast, only IgG antibody was active in the P-K type test to sensitize a heterologous species (guinea pig). None of the antibodies of other classes showed sensitizing activity in heterologous skin. The 7S IgA antibody lost its sensitizing activity upon reduction and alkylation, although no change in its molecular size could be observed. The loss of sensitizing activity was not due to the destruction of antigen-binding activity since the treated 7S IgA antibody retained this activity as shown by radioimmunoelectrophoresis and by binding to the specific immunoadsorbent. The 9S IgA antibody was more resistant to these treatments than the IgM antibody and showed no indication of dissociation. The treated 9S IgA also retained antigen-binding activity. Both the P-K type and PCA reactions were considerably stronger when the interval between injections of antibody and antigen was 24 hr rather than 4 to 5 hr. PMID:4159250

  2. Assessment of the sensitizing potency of preservatives with chance of skin contact by the loose-fit coculture-based sensitization assay (LCSA).

    PubMed

    Sonnenburg, Anna; Schreiner, Maximilian; Stahlmann, Ralf

    2015-12-01

    Parabens, methylisothiazolinone (MI) and its derivative methylchloroisothiazolinone (MCI), are commonly used as preservatives in personal care products. They can cause hypersensitivity reactions of the human skin. We have tested a set of nine parabens, MI alone and in combination with MCI in the loose-fit coculture-based sensitization assay (LCSA). The coculture of primary human keratinocytes and allogenic dendritic cell-related cells (DC-rc) in this assay emulates the in vivo situation of the human skin. Sensitization potency of the test substances was assessed by flow cytometric analysis of the DC-rc maturation marker CD86. Determination of the concentration required to cause a half-maximal increase in CD86-expression (EC50sens) allowed a quantitative evaluation. The cytotoxicity of test substances as indicator for irritative potency was measured by 7-AAD (7-amino-actinomycin D) staining. Parabens exhibited weak (methyl-, ethyl-, propyl- and isopropylparaben) or strong (butyl-, isobutyl-, pentyl- and benzylparaben) effects, whereas phenylparaben was found to be a moderate sensitizer. Sensitization potencies of parabens correlated with side chain length. Due to a pronounced cytotoxicity, we could not estimate an EC50sens value for MI, whereas MI/MCI was classified as sensitizer and also showed cytotoxic effects. Parabens showed no (methyl- and ethylparaben) or weak irritative potencies (propyl-, isopropyl-, butyl-, isobutyl-, phenyl- and benzylparaben), only pentylparaben was rated to be irritative. Overall, we were able to demonstrate and compare the sensitizing potencies of parabens in this in vitro test. Furthermore, we showed an irritative potency for most of the preservatives. The data further support the usefulness of the LCSA for comparison of the sensitizing potencies of xenobiotics.

  3. Rapid quantification of color vision: the cone contrast test.

    PubMed

    Rabin, Jeff; Gooch, John; Ivan, Douglas

    2011-02-09

    To describe the design, specificity, and sensitivity of the cone contrast test (CCT), a computer-based, cone-specific (L, M, S) contrast sensitivity test for diagnosing type and severity of color vision deficiency (CVD). The CCT presents a randomized series of colored letters visible only to L, M or S cones in decreasing steps of cone contrast to determine L, M, and S letter-recognition thresholds. Sensitivity and specificity were determined by retrospective comparison of CCT scores to anomaloscope and pseudoisochromatic plate (PIP) results in 1446 applicants for pilot training. CVD was detected in 49 (3.4%) of 1446 applicants with hereditary red-green (protan or deutan) CVD detected in 47 (3.5%) of 1359 men and blue-yellow (tritan) in 2 of 1446. In agreement with the anomaloscope, the CCT showed 100% sensitivity for detection and categorization of CVD (40 deutan, 7 protan, 2 tritan). PIP testing showed lower sensitivity (80% detected; 20% missed) due in part to the applicant's prior experience and/or pretest preparation. CCT specificity for confirming normal color vision was 100% for L and M cone tests and 99.8% for S cones. The CCT has sensitivity and specificity comparable to anomaloscope testing and exceeds PIP sensitivity in practiced observers. The CCT provides a rapid (6 minutes), clinically expedient, measure of color vision for quantifying normal color performance, diagnosing type and severity of hereditary deficiency, and detection of acquired sensitivity loss due to ocular, neurologic, and/or systemic disease, as well as injury and physiological stressors, such as altitude and fatigue.

  4. Kinesthetic sensitivity and related measures of hand sensitivity in children with nonproficient handwriting.

    PubMed

    Brink, Anne O'Leary; Jacobs, Anne Burleigh

    2011-01-01

    This study compared measures of hand sensitivity and handwriting quality in children aged 10 to 12 years identified by their teachers as having nonproficient or proficient handwriting. We hypothesized that children with nonproficient handwriting have decreased kinesthetic sensitivity of the hands and digits. Sixteen subjects without documented motor or cognitive concerns were tested for kinesthetic sensitivity, discriminate tactile awareness, diadochokinesia, stereognosis, and graphesthesia. Eight children were considered to have nonproficient handwriting; 8 had proficient handwriting. Nonparametric Mann-Whitney U tests were used to identify differences between groups on sensory tests. The 2 groups showed a statistically significant difference in handwriting legibility (P = .018). No significant difference was found on tests of kinesthetic sensitivity or other measures of sensation. Children presenting with handwriting difficulty as the only complaint have similar sensitivity in hands and digits as those with proficient handwriting. Failure to detect differences may result from a small sample size.

  5. Empirical likelihood-based confidence intervals for the sensitivity of a continuous-scale diagnostic test at a fixed level of specificity.

    PubMed

    Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi

    2011-06-01

    For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.

  6. Comparative Evaluation of Four Phenotypic Tests for Detection of Carbapenemase-Producing Gram-Negative Bacteria

    PubMed Central

    Noël, Audrey; Berhin, Catherine; Hoebeke, Martin; Bouchahrouf, Warda; Yunus, Sami; Bogaerts, Pierre; Glupczynski, Youri

    2016-01-01

    ABSTRACT Four screening assays aimed for rapid detection of carbapenemase production from Gram-negative bacterial isolates, i.e., the Neo-Rapid Carb kit (Rosco Diagnostica A/S), the Rapidec Carba NP test (bioMérieux SA), the β Carba test (Bio-Rad Laboratories N.V.), and a homemade electrochemical assay (BYG Carba test) were evaluated against a panel comprising 328 clinical isolates (Enterobacteriaceae [n = 198] and nonfermentative Gram-negative bacilli [n = 130]) with previously characterized resistance mechanisms to carbapenems. Among Enterobacteriaceae isolates, the BYG Carba test and the β Carba test showed excellent sensitivities (respectively, 100% and 97.3%) and specificities (respectively, 98.9% and 97.7%). The two other assays yielded poorer performances with sensitivity and specificity of 91.9% and 83.9% for the Rapidec Carba NP test and of 89.2% and 89.7% for the Neo-Rapid Carb kit, respectively. Among Pseudomonas spp., sensitivities and specificities ranged, respectively, from 87.3% to 92.7% and from 88.2% to 94.1%. Finally, all tests performed poorly against Acinetobacter spp., with sensitivities and specificities, respectively, ranging from 27.3% to 75.8% and from 75 to 100%. Among commercially available assays, the β Carba test appeared to be the most convenient for routine use and showed the best overall performances, especially against OXA-48-like producers. The excellent performance of the BYG Carba test against Enterobacteriaceae was confirmed (100% sensitivity and 98.9% specificity). PMID:27927915

  7. The development and initial validation of a sensitive bedside cognitive screening test.

    PubMed

    Faust, D; Fogel, B S

    1989-01-01

    Brief bedside cognitive examinations such as the Mini-Mental State Examination are designed to detect delirium and dementia but not more subtle or delineated cognitive deficits. Formal neuropsychological evaluation provides greater sensitivity and detects a wider range of cognitive deficits but is too lengthy for efficient use at the bedside or in epidemiological studies. The authors developed the High Sensitivity Cognitive Screen (HSCS), a 20-minute interview-based test, to identify patients who show disorder on formal neuropsychological evaluation. An initial study demonstrated satisfactory test-retest and interrater reliability. The HSCS was then administered to 60 psychiatric and neurological patients with suspected cognitive deficits but without gross impairment, who also completed formal neuropsychological testing. Results of both tests were independently classified as either normal, borderline, or abnormal. The HSCS correctly classified 93% of patients across the normal-abnormal dichotomy and showed promise for characterizing the extent and severity of cognitive dysfunction.

  8. Computer-aided detection in musculoskeletal projection radiography: A systematic review.

    PubMed

    Gundry, M; Knapp, K; Meertens, R; Meakin, J R

    2018-05-01

    To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  9. In vitro sensitivities to antimicrobial drugs of ureaplasmas isolated from the bovine respiratory tract, genital tract and eye.

    PubMed

    Kishima, M; Hashimoto, K

    1979-09-01

    The sensitivity to 18 antimicrobial drugs was examined for 66 strains of Ureaplasma sp isolated from respiratory tracts of calves suffering from enzootic pneumonia, urinary tracts of bulls and eyes of cows suffering from infectious bovine kerato-conjunctivitis. Furamizole, tiamulin fumarate, erythromycin lactobionate, malidomycin C, doxycycline hydrochloride, kitasamycin tartrate, tylosin tartrate, T-2636C, tetracycline hydrochloride, oxytetracycline hydrochloride, chlortetracycline hydrochloride, oleandomycin phosphate, furazolidone, spiramycin adipate, chloramphenicol and thiophenicol showed strong inhibiting activity on all the test strains. Among them, furamizole, tiamulin fumarate and erythromycin lactobionate were most active. Kanamycin sulphate showed weak activity on all the strains tested. The differences in origin of the test strains did not affect their sensitivity to any of the drugs.

  10. Zebrafish embryotoxicity test for developmental (neuro)toxicity: Demo case of an integrated screening approach system using anti-epileptic drugs.

    PubMed

    Beker van Woudenberg, Anna; Snel, Cor; Rijkmans, Eke; de Groot, Didima; Bouma, Marga; Hermsen, Sanne; Piersma, Aldert; Menke, Aswin; Wolterbeek, André

    2014-11-01

    To improve the predictability of the zebrafish embryotoxicity test (ZET) for developmental (neuro)toxicity screening, we used a multiple-endpoints strategy, including morphology, motor activity (MA), histopathology and kinetics. The model compounds used were antiepileptic drugs (AEDs): valproic acid (VPA), carbamazepine (CBZ), ethosuximide (ETH) and levetiracetam (LEV). For VPA, histopathology was the most sensitive parameter, showing effects already at 60μM. For CBZ, morphology and MA were the most sensitive parameters, showing effects at 180μM. For ETH, all endpoints showed similar sensitivity (6.6mM), whereas MA was the most sensitive parameter for LEV (40mM). Inclusion of kinetics did not alter the absolute ranking of the compounds, but the relative potency was changed considerably. Taking all together, this demo-case study showed that inclusion of multiple-endpoints in ZET may increase the sensitivity of the assay, contribute to the elucidation of the mode of toxic action and to a better definition of the applicability domain of ZET. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Ecotoxicity of wastes in avoidance tests with Enchytraeus albidus, Enchytraeus crypticus and Eisenia fetida (Oligochaeta).

    PubMed

    Kobeticová, Klára; Hofman, Jakub; Holoubek, Ivan

    2010-04-01

    Contact bioassays are important for testing the ecotoxicity of solid materials. However, survival and reproduction tests are often not practical due to their duration which may last for several weeks. Avoidance tests with soil invertebrates may offer an alternative or extension to the classic test batteries due to their short duration (days rather than weeks) and due to a sensitive sub-acute endpoint (behavior). (a) to evaluate the effects of three solid industrial wastes (incineration ash, contaminated wood chips and contaminated soil) on three Oligochaeta species (enchytraeids Enchytraeusalbidus, Enchytraeus crypticus and earthworm Eisenia fetida) in avoidance tests; (b) to compare the sensitivity among the species and to compare results of avoidance test to reproduction tests; (c) to elucidate if measuring the weight in the earthworm avoidance test could be reasonable additional endpoint. Avoidance mostly increased with the increasing percent of waste in the mixture showing a dose-response curve. E. fetida was the most sensitive species and E. crypticus the least one. An additional endpoint, (changes in weight after two-day exposure) was not found to be more sensitive than avoidance reaction, but it confirmed that earthworms staying in the highest concentrations of the waste mixture were affected showing apparent weight reduction. Our results indicate that avoidance tests with earthworms and enchytraeids are feasible for waste testing. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. [Evaluation of ICT malaria immunochromatographic Binax NOW ICT P.f/P.v test for rapid diagnosis of malaria in a Colombian endemic area].

    PubMed

    Pabón, Adriana; Alvarez, Gonzalo; Yánez, Jorge; Céspedes, Carlos; Rodríguez, Yensa; Restrepo, Angela; Blair, Silvia

    2007-06-01

    One of the strategies to reduce malarial morbidity and mortality is to make an early diagnosis, using simple rapid tests which are highly sensitive and specific. Furthermore, the tests must be easy to perform and understand by local people in such a way that a suitable and prompt antimalarial treatment is guaranteed. The sensitivity and specificity was determined for the immuno-chromographic malaria dipstick (ICT Pf/Pv) test for the rapid diagnosis of malaria in Turbo, Antioquia. The sample consisted of 171 patients distributed into two groups: the first group was 118 patients with acute febrile syndrome compatible with malaria to which ICT Pf/Pv and thick smears were applied simultaneously; a second group was 53 patients with positive diagnosis by thick smear, with follow-up on the 4th and 7th days after beginning treatment. Sensitivity and specificity of the ICT Pf/Pv test for Plasmodium falciparum infections were 54.2% (95%CI: 52.0-53.4%) and 93.6% (95%CI: 93.1-94.2%), respectively. In addition, for Plasmodium vivax the sensitivity and specificity were 80% (95%CI: 77.9-82.1%) and 100% (95%CI: 99.5-100%); there was a 21.4% loss of sensitivity for P. falciparum 21.4% and a 33% loss for P. vivax malaria with parasitaemias under 500 parasites/ul. For the confirmatory test, ICT Pf/Pv showed a global sensitivity of 71.6% with 20.7% false positive and 5.6% false negative results. During follow-up, ICT showed 36% and 34% false positive results for day 4 and 7, respectively. The ICT Pf/Pv test has a poor sensitivity for P. falciparum malaria and its capacity to detect parasitemias under 500 parasites/ul is minimal. As a confirmatory test, the ICT Pf/Pv has a good sensitivity for P. falciparum. Its use for patient follow-up is not recommended.

  13. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    PubMed

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  14. In vitro fungicide sensitivity of Rhizoctonia isolates collected from turfgrasses

    USDA-ARS?s Scientific Manuscript database

    Different Rhizoctonia species and anastomosis groups (AGs) have been reported to show variable sensitivity to various commercial fungicides. Thirty–six isolates of Rhizoctonia collected from turfgrasses were tested in vitro for sensitivity to commercial formulations of iprodione, triticonazole, and ...

  15. Diagnostic accuracy of three monoclonal stool tests in a large series of untreated Helicobacter pylori infected patients.

    PubMed

    Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier

    2016-06-01

    Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Correlation of phenotypic tests with the presence of the blaZ gene for detection of beta-lactamase.

    PubMed

    Ferreira, Adriano Martison; Martins, Katheryne Benini; Silva, Vanessa Rocha da; Mondelli, Alessandro Lia; Cunha, Maria de Lourdes Ribeiro de Souza da

    Staphylococcus aureus and Staphylococcus saprophyticus are the most common and most important staphylococcal species associated with urinary tract infections. The objective of the present study was to compare and to evaluate the accuracy of four phenotypic methods for the detection of beta-lactamase production in Staphylococcus spp. Seventy-three strains produced a halo with a diameter ≤28mm (penicillin resistant) and all of them were positive for the blaZ gene. Among the 28 susceptible strain (halo ≥29mm), 23 carried the blaZ gene and five did not. The zone edge test was the most sensitive (90.3%), followed by MIC determination (85.5%), but the specificity of the former was low (40.0%). The nitrocefin test was the least sensitive (28.9%). However, the nitrocefin test together with the disk diffusion method showed the highest specificity (100%). The present results demonstrated that the zone edge test was the most sensitive phenotypic test for detection of beta-lactamase, although it is still not an ideal test to detect this type of resistance since its specificity was low. However, the inhibition halo diameter of the penicillin disk can be used together with the zone edge test since the same disk is employed in the two tests. Combined analysis of the two tests shows a sensitivity of 90.3% and specificity of 100%, proving better sensitivity, especially for S. saprophyticus. This is a low-cost test of easy application and interpretation that can be used in small and medium-sized laboratories where susceptibility testing is usually performed by the disk diffusion method. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  17. Diagnosis of Normal and Abnormal Color Vision with Cone-Specific VEPs.

    PubMed

    Rabin, Jeff C; Kryder, Andrew C; Lam, Dan

    2016-05-01

    Normal color vision depends on normal long wavelength (L), middle wavelength (M), and short wavelength sensitive (S) cones. Hereditary "red-green" color vision deficiency (CVD) is due to a shift in peak sensitivity or lack of L or M cones. Hereditary S cone CVD is rare but can be acquired as an early sign of disease. Current tests detect CVD but few diagnose type or severity, critical for linking performance to real-world demands. The anomaloscope and newer subjective tests quantify CVD but are not applicable to infants or cognitively impaired patients. Our purpose was to develop an objective test of CVD with sensitivity and specificity comparable to current tests. A calibrated visual-evoked potential (VEP) display and Food and Drug Administration-approved system was used to record L, M, and S cone-specific pattern-onset VEPs from 18 color vision normals (CVNs) and 13 hereditary CVDs. VEP amplitudes and latencies were compared between groups to establish VEP sensitivity and specificity. Cone VEPs show 100% sensitivity for diagnosis of CVD and 94% specificity for confirming CVN. L cone (protan) CVDs showed a significant increase in L cone latency (53.1 msec, P < 0.003) and decreased amplitude (10.8 uV, P < 0.0000005) but normal M and S cone VEPs ( P > 0.31). M cone (deutan) CVDs showed a significant increase in M cone latency (31.0 msec, P < 0.000004) and decreased amplitude (8.4 uV, P < 0.006) but normal L and S cone VEPs ( P > 0.29). Cone-specific VEPs offer a rapid, objective test to diagnose hereditary CVD and show potential for detecting acquired CVD in various diseases. This paper describes the efficacy of cone-specific color VEPs for quantification of normal and abnormal color vision. The rapid, objective nature of this approach makes it suitable for detecting color sensitivity loss in infants and the cognitively impaired.

  18. Contextual and behavioral control of antipsychotic sensitization induced by haloperidol and olanzapine.

    PubMed

    Zhang, Chen; Li, Ming

    2012-02-01

    Repeated administration of haloperidol (HAL) and olanzapine (OLZ) causes a progressively enhanced disruption of the conditioned avoidance response (CAR) and a progressively enhanced inhibition of phencyclidine (PCP)-induced hyperlocomotion in rats (termed antipsychotic sensitization). Both actions are thought to reflect intrinsic antipsychotic activity. The present study examined the extent to which antipsychotic-induced sensitization in one model (e.g. CAR) can be transferred or maintained in another (e.g. PCP hyperlocomotion) as a means of investigating the contextual and behavioral controls of antipsychotic sensitization. Well-trained male Sprague-Dawley rats were first repeatedly tested in the CAR or the PCP (3.2 mg/kg, subcutaneously) hyperlocomotion model under HAL or OLZ for 5 consecutive days. Then they were switched to the other model and tested for the expression of sensitization. Finally, all rats were switched back to the original model and retested for the expression of sensitization. Repeated HAL or OLZ treatment progressively disrupted avoidance responding and decreased PCP-induced hyperlocomotion, indicating a robust sensitization. When tested in a different model, rats previously treated with HAL or OLZ did not show a stronger inhibition of CAR-induced or PCP-induced hyperlocomotion than those treated with these drugs for the first time; however, they did show such an effect when tested in the original model in which they received repeated antipsychotic treatment. These findings suggest that the expression of antipsychotic sensitization is strongly influenced by the testing environment and/or selected behavioral response under certain experimental conditions. Distinct contextual cues and behavioral responses may develop an association with unconditional drug effects through a Pavlovian conditioning process. They may also serve as occasion setters to modulate the expression of sensitized responses. As antipsychotic sensitization mimics the clinical effects of antipsychotic treatment, understanding the neurobiological mechanisms of antipsychotic sensitization and its contextual control would greatly enhance our understanding of the psychological and neurochemical nature of antipsychotic treatment in the clinic.

  19. Contextual and behavioral control of antipsychotic sensitization induced by haloperidol and olanzapine

    PubMed Central

    Zhang, Chen; Li, Ming

    2011-01-01

    Repeated administration of haloperidol and olanzapine causes a progressively enhanced disruption of conditioned avoidance response (CAR) and a progressively enhanced inhibition of phencyclidine (PCP)-induced hyperlocomotion in rats (termed antipsychotic sensitization). Both actions are thought to reflect intrinsic antipsychotic activity. The present study examined to the extent to which antipsychotic-induced sensitization in one model (e.g. CAR) can be transferred or maintained in another (e.g. PCP hyperlocomotion) as a means of investigating the contextual and behavioral controls of antipsychotic sensitization. Well-trained male Sprague-Dawley rats were first repeatedly tested in the CAR or PCP (3.2 mg/kg, sc) hyperlocomotion model under haloperidol or olanzapine for five consecutive days. Then they were switched to the other model and tested for the expression of sensitization. Finally, all rats were switched back to the original model and retested for the expression of sensitization. Repeated haloperidol or olanzapine treatment progressively disrupted avoidance responding and decreased PCP-induced hyperlocomotion, indicating a robust sensitization. When tested in a different model, rats previously treated with haloperidol or olanzapine did not show a stronger inhibition of CAR or PCP-induced hyperlocomotion than those treated with these drugs for the first time; however, they did show such an effect when tested in the original model in which they received repeated antipsychotic treatment. These findings suggest that the expression of antipsychotic sensitization is strongly influenced by the testing environment and/or selected behavioral response under certain experimental conditions. Distinct contextual cues and behavioral responses may enter an association with unconditional drug effects via a Pavlovian conditioning process. They may also serve as occasion-setters to modulate the expression of sensitized responses. Because antipsychotic sensitization mimics clinical effects of antipsychotic treatment, understanding the neurobiological mechanisms of antipsychotic sensitization and its contextual control would greatly enhance our understanding of the psychological and neurochemical nature of antipsychotic treatment in the clinic. PMID:22157143

  20. A Novel Quantum Dots-Based Point of Care Test for Syphilis

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang

    2010-05-01

    One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.

  1. Correlation between the immunological condition and the results of immunoenzymatic tests in diagnosing infectious mononucleosis.

    PubMed

    Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio

    2009-04-01

    A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.

  2. Evaluation of a new reagent for anti-cytomegalovirus and anti-Epstein-Barr virus immunoglobulin G.

    PubMed Central

    Gutierrez, J; Maroto, M D; Piédrola, G

    1994-01-01

    The Enzygnost alpha method was tested against the complement fixation test and anti-VCA immunofluorescence to determine the respective titers of anti-cytomegalovirus and anti-Epstein-Barr virus immunoglobulin G antibodies. For cytomegalovirus, the Enzygnost results showed 97.99% agreement with the readings obtained by the alternative method, with 100% sensitivity and 93.7% specificity. For Epstein-Barr virus, Enzygnost showed 97.71% agreement, 100% sensitivity, and 91.11% specificity. PMID:7814510

  3. Application of artificial neural network to predict clay sensitivity in a high landslide prone area using CPTu data- A case study in Southwest of Sweden

    NASA Astrophysics Data System (ADS)

    Shahri, Abbas; Mousavinaseri, Mahsasadat; Naderi, Shima; Espersson, Maria

    2015-04-01

    Application of Artificial Neural Networks (ANNs) in many areas of engineering, in particular to geotechnical engineering problems such as site characterization has demonstrated some degree of success. The present paper aims to evaluate the feasibility of several various types of ANN models to predict the clay sensitivity of soft clays form piezocone penetration test data (CPTu). To get the aim, a research database of CPTu data of 70 test points around the Göta River near the Lilli Edet in the southwest of Sweden which is a high prone land slide area were collected and considered as input for ANNs. For training algorithms the quick propagation, conjugate gradient descent, quasi-Newton, limited memory quasi-Newton and Levenberg-Marquardt were developed tested and trained using the CPTu data to provide a comparison between the results of field investigation and ANN models to estimate the clay sensitivity. The reason of using the clay sensitivity parameter in this study is due to its relation to landslides in Sweden.A special high sensitive clay namely quick clay is considered as the main responsible for experienced landslides in Sweden which has high sensitivity and prone to slide. The training and testing program was started with 3-2-1 ANN architecture structure. By testing and trying several various architecture structures and changing the hidden layer in order to have a higher output resolution the 3-4-4-3-1 architecture structure for ANN in this study was confirmed. The tested algorithm showed that increasing the hidden layers up to 4 layers in ANN can improve the results and the 3-4-4-3-1 architecture structure ANNs for prediction of clay sensitivity represent reliable and reasonable response. The obtained results showed that the conjugate gradient descent algorithm with R2=0.897 has the best performance among the tested algorithms. Keywords: clay sensitivity, landslide, Artificial Neural Network

  4. Comparison of presumptive blood test kits including hexagon OBTI.

    PubMed

    Johnston, Emma; Ames, Carole E; Dagnall, Kathryn E; Foster, John; Daniel, Barbara E

    2008-05-01

    Four presumptive blood tests, Hexagon OBTI, Hemastix(R), Leucomalachite green (LMG), and Kastle-Meyer (KM) were compared for their sensitivity in the identification of dried bloodstains. Stains of varying blood dilutions were subjected to each presumptive test and the results compared. The Hexagon OBTI buffer volume was also reduced to ascertain whether this increased the sensitivity of the kit. The study found that Hemastix(R) was the most sensitive test for trace blood detection. Only with the reduced buffer volume was the Hexagon OBTI kit as sensitive as the LMG and KM tests. However, the Hexagon OBTI kit has the advantage of being a primate specific blood detection kit. This study also investigated whether the OBTI buffer within the kit could be utilized for DNA profiling after presumptive testing. The results show that DNA profiles can be obtained from the Hexagon OBTI kit buffer directly.

  5. Diagnostic Accuracy, Sensitivity, and Specificity of Executive Function Tests in Moderate Traumatic Brain Injury in Ghana.

    PubMed

    Adjorlolo, Samuel

    2018-06-01

    The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.

  6. Anaphylaxis to Gelofusine confirmed by in vitro basophil activation test: a case series.

    PubMed

    Apostolou, E; Deckert, K; Puy, R; Sandrini, A; de Leon, M P; Douglass, J A; Rolland, J M; O'hehir, R E

    2006-03-01

    The plasma expander Gelofusine (succinylated gelatin) is a recognised cause of peri-operative anaphylaxis. Current diagnosis of Gelofusine sensitivity is by skin testing, a procedure that itself carries a risk of allergic reaction. We evaluated the reliability of the in vitro basophil activation test as a diagnostic assay for Gelofusine sensitivity in subjects with a clinical history highly suggestive of Gelofusine allergy. Six patients with peri-operative anaphylaxis clinically attributed to Gelofusine were skin tested to confirm sensitivity. Control subjects included three healthy subjects and five subjects allergic to a neuromuscular blocking drug, all negative on Gelofusine skin testing. Whole blood basophil activation to Gelofusine was analysed by flow cytometry for CD63 surface expression. All of the Gelofusine sensitive patients and one of the control allergic subjects showed positive basophil activation to Gelofusine. In this series of subjects, the basophil activation test for Gelofusine allergy had a sensitivity of 100% and a specificity of 87.5%. Our findings suggest that basophil activation testing is a safe and reliable in vitro assay for prediction or confirmation of Gelofusine sensitivity in patients with high clinical suspicion of Gelofusine-induced anaphylaxis.

  7. Individual Test Point Fluctuations of Macular Sensitivity in Healthy Eyes and Eyes With Age-Related Macular Degeneration Measured With Microperimetry.

    PubMed

    Barboni, Mirella Telles Salgueiro; Szepessy, Zsuzsanna; Ventura, Dora Fix; Németh, János

    2018-04-01

    To establish fluctuation limits, it was considered that not only overall macular sensitivity but also fluctuations of individual test points in the macula might have clinical value. Three repeated measurements of microperimetry were performed using the Standard Expert test of Macular Integrity Assessment (MAIA) in healthy subjects ( N = 12, age = 23.8 ± 1.5 years old) and in patients with age-related macular degeneration (AMD) ( N = 11, age = 68.5 ± 7.4 years old). A total of 37 macular points arranged in four concentric rings and in four quadrants were analyzed individually and in groups. The data show low fluctuation of macular sensitivity of individual test points in healthy subjects (average = 1.38 ± 0.28 dB) and AMD patients (average = 2.12 ± 0.60 dB). Lower sensitivity points are more related to higher fluctuation than to the distance from the central point. Fixation stability showed no effect on the sensitivity fluctuation. The 95th percentile of the standard deviations of healthy subjects was, on average, 2.7 dB, ranging from 1.2 to 4 dB, depending on the point tested. Point analysis and regional analysis might be considered prior to evaluating macular sensitivity fluctuation in order to distinguish between normal variation and a clinical change. S tatistical methods were used to compare repeated microperimetry measurements and to establish fluctuation limits of the macular sensitivity. This analysis could add information regarding the integrity of different macular areas and provide new insights into fixation points prior to the biofeedback fixation training.

  8. [Tumor markers for bladder cancer: up-to-date study by the Kiel Tumor Bank].

    PubMed

    Hautmann, S; Eggers, J; Meyhoff, H; Melchior, D; Munk, A; Hamann, M; Naumann, M; Braun, P M; Jünemann, K P

    2007-11-01

    The number of noninvasive diagnostic tests for bladder cancer has increased tremendously over the last years with a large number of experimental and commercial tests. Comparative analyses of tests for diagnosis, follow-up, and recurrence detection of bladder cancer were performed retrospectively as well as prospectively, unicentrically, and multicentrically. An analysis of multicentric studies with large patient numbers compared with our own Kiel Tumor Bank data is presented. The Kiel Tumor Bank data looked prospectively at 106 consecutive bladder tumor patients from the year 2006. Special focus was put on urine cytology as a reference test, as well as the commercial NMP 22 Bladder Chek. The analysis of the NMP 22 Bladder Chek showed an overall sensitivity of 69% for all tumor grades and stages, with a specificity of 76%. Comparison to multicentric data with an overall sensitivity of 75% for all tumor grades and stages, with a specificity of 73%, showed results similar to those in the literature. Urine cytology showed a comparable overall sensitivity of 73% for all tumor grades and stages, with a specificity of 80%. A large number of noninvasive tests for bladder cancer follow-up with reasonable sensitivity and specificity can currently be used. Because of limited numbers of prospective randomized multicentric studies, no single particular marker for bladder cancer screening can be recommended at this point in time.

  9. Effects of blur and repeated testing on sensitivity estimates with frequency doubling perimetry.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; McCormick, Terry A; LeBlanc, Raymond P; Chauhan, Balwantray C

    2003-02-01

    To investigate the effect of blur and repeated testing on sensitivity with frequency doubling technology (FDT) perimetry. One eye of 12 patients with glaucoma (mean deviation [MD] mean, -2.5 dB, range +0.5 to -4.3 dB) and 11 normal control subjects underwent six consecutive tests with the FDT N30 threshold program in each of two sessions. In session 1, blur was induced by trial lenses (-6.00, -3.00, 0.00, +3.00, and +6.00 D, in random order). In session 2, only the effects of repeated testing were evaluated. The MD and pattern standard deviation (PSD) indices were evaluated as functions of blur and of test order. By correcting the data of session 1 for the reduction of sensitivity with repeated testing (session 2), the effect of blur on FDT sensitivities was established, and its clinical consequences evaluated on total- and pattern-deviation probability maps. FDT sensitivities decreased with blur (by <0.5 dB/D) and with repeated testing (by approximately 2 dB between the first and sixth tests). Blur and repeated testing independently led to larger numbers of locations with significant total and pattern deviation. Sensitivity reductions were similar in normal control subjects and patients with glaucoma, at central and peripheral test locations and at locations with high and low sensitivities. However, patients with glaucoma showed larger deterioration in the total-deviation-probability maps. To optimize the performance of the device, refractive errors should be corrected and immediate retesting avoided. Further research is needed to establish the cause of sensitivity loss with repeated FDT testing.

  10. Developmental toxicity, acute toxicity and mutagenicity testing in freshwater snails Biomphalaria glabrata (Mollusca: Gastropoda) exposed to chromium and water samples.

    PubMed

    Tallarico, Lenita de Freitas; Borrely, Sueli Ivone; Hamada, Natália; Grazeffe, Vanessa Siqueira; Ohlweiler, Fernanda Pires; Okazaki, Kayo; Granatelli, Amanda Tosatte; Pereira, Ivana Wuo; Pereira, Carlos Alberto de Bragança; Nakano, Eliana

    2014-12-01

    A protocol combining acute toxicity, developmental toxicity and mutagenicity analysis in freshwater snail Biomphalaria glabrata for application in ecotoxicological studies is described. For acute toxicity testing, LC50 and EC50 values were determined; dominant lethal mutations induction was the endpoint for mutagenicity analysis. Reference toxicant potassium dichromate (K2Cr2O7) was used to characterize B. glabrata sensitivity for toxicity and cyclophosphamide to mutagenicity testing purposes. Compared to other relevant freshwater species, B. glabrata showed high sensitivity: the lowest EC50 value was obtained with embryos at veliger stage (5.76mg/L). To assess the model applicability for environmental studies, influent and effluent water samples from a wastewater treatment plant were evaluated. Gastropod sensitivity was assessed in comparison to the standardized bioassay with Daphnia similis exposed to the same water samples. Sampling sites identified as toxic to daphnids were also detected by snails, showing a qualitatively similar sensitivity suggesting that B. glabrata is a suitable test species for freshwater monitoring. Holding procedures and protocols implemented for toxicity and developmental bioassays showed to be in compliance with international standards for intra-laboratory precision. Thereby, we are proposing this system for application in ecotoxicological studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Comparison of five methods of malaria detection in the outpatient setting.

    PubMed

    Lema, O E; Carter, J Y; Nagelkerke, N; Wangai, M W; Kitenge, P; Gikunda, S M; Arube, P A; Munafu, C G; Materu, S F; Adhiambo, C A; Mukunza, H K

    1999-02-01

    In eastern Africa where 90% of the malaria is due to Plasmodium falciparum, the accuracy of malaria diagnosis at the outpatient level is becoming increasingly important due to problems of drug resistance and use of alternative, costly antimalarial drugs. The quantitative buffy coat (QBC) technique, acridine orange staining with an interference filter system, and the ParaSight-F test have been introduced as alternative methods to conventional microscopy for the diagnosis of malaria. Two hundred thirteen outpatients were tested using these alternative methods and conventional microscopy by five experienced technologists; two were randomly allocated to read the results of each test. Paired results showed the highest level of agreement with the ParaSight-F test (99%), followed by Field stain (92%). The results of the QBC technique showed the least agreement (73%). Using conventional microscopy as the reference standard, the ParaSight-F test had a sensitivity range of 90-92% and a specificity of 99%, staining with acridine orange had a sensitivity range of 77-96% and a specificity range of 81-98% and the QBC technique had a sensitivity range of 88-98% and a specificity range of 58-90%. All microscopic tests showed lower sensitivities (as low as 20% using staining with acridine orange) in detecting low parasitemias (< or = 320/microl) than the ParaSight-F test (70%). Due to the high cost of the ParaSight-F test, Field-stained blood films remain the most appropriate method for diagnosis of P. falciparum in eastern Africa. The ParaSight-F test may be used in situations where no trained microscopists are available, or where malaria is strongly suspected and the results of microscopy are negative.

  12. Localized periorbital edema as a clinical manifestation of sulfite sensitivity.

    PubMed

    Park, H S; Nahm, D

    1996-08-01

    Sulfite is commonly used in pharmaceuticals as a preservative. We report a unique clinical presentation of localized periorbital edema on the left eye after administration of sulfite-containing dexamethasone. The patient's sulfite sensitivity was confirmed by sulfite oral provocation test: periorbital edema on the same site developed after ingestion of 200 mg sodium bisulfite. She was non-atopic and did not complain of any respiratory symptoms. Allergy skin prick test with 100 mg/ml sodium bisulfite showed a negative result. She also has aspirin-sensitive urticaria which was confirmed by oral provocation test. In conclusion, sulfite can induce a localized periorbital edema, an uncommon manifestation in sensitive patients. Further investigations are needed to clarify the pathogenetic mechanisms.

  13. Modulating influences of memory strength and sensitivity of the retrieval test on the detectability of the sleep consolidation effect.

    PubMed

    Schoch, Sarah F; Cordi, Maren J; Rasch, Björn

    2017-11-01

    Emotionality can increase recall probability of memories as emotional information is highly relevant for future adaptive behavior. It has been proposed that memory processes acting during sleep selectively promote the consolidation of emotional memories, so that neutral memories no longer profit from sleep consolidation after learning. This appears as a selective effect of sleep for emotional memories. However, other factors contribute to the appearance of a consolidation benefit and influence this interpretation. Here we show that the strength of the memory trace before sleep and the sensitivity of the retrieval test after sleep are critical factors contributing to the detection of the benefit of sleep on memory for emotional and neutral stimuli. 228 subjects learned emotional and neutral pictures and completed a free recall after a 12-h retention interval of either sleep or wakefulness. We manipulated memory strength by including an immediate retrieval test before the retention interval in half of the participants. In addition, we varied the sensitivity of the retrieval test by including an interference learning task before retrieval testing in half of the participants. We show that a "selective" benefit of sleep for emotional memories only occurs in the condition with high memory strength. Furthermore, this "selective" benefit disappeared when we controlled for the memory strength before the retention interval and used a highly sensitive retrieval test. Our results indicate that although sleep benefits are more robust for emotional memories, neutral memories similarly profit from sleep after learning when more sensitive indicators are used. We conclude that whether sleep benefits on memory appear depends on several factors, including emotion, memory strength and sensitivity of the retrieval test. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats.

    PubMed

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P M; Groschup, Martin H; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Van Keulen, Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-03-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity, with the IDEXX test significantly more sensitive than the 2 Bio-Rad tests. All tests detected 100% of samples from goats with clinical scrapie, but missed 8% (IDEXX) to 33% (Bio-Rad SG) of samples from preclinical goats. Importantly, only IDEXX picked up all samples from clinical bovine spongiform encephalopathy (BSE)-infected goats, whereas the other 2 rapid tests missed 15% (Bio-Rad SG) to 25% (Bio-Rad SAP). These results show that a fraction of preclinical scrapie infections are likely missed by EU surveillance, with sensitivity of detection strongly dependent on the choice of the rapid test. Moreover, a significant proportion of clinical BSE infections are underestimated by using either Bio-Rad test. Assuming that the same sensitivity on preclinical goats would also occur in BSE-infected goats, our data suggest that IDEXX is likely the most sensitive test for detecting preclinical field cases of BSE infection in goats, although with an 8% failure rate. These results raise some concerns about the reliability of current EU surveillance figures on BSE infection in goats.

  15. Does McNemar's test compare the sensitivities and specificities of two diagnostic tests?

    PubMed

    Kim, Soeun; Lee, Woojoo

    2017-02-01

    McNemar's test is often used in practice to compare the sensitivities and specificities for the evaluation of two diagnostic tests. For correct evaluation of accuracy, an intuitive recommendation is to test the diseased and the non-diseased groups separately so that the sensitivities can be compared among the diseased, and specificities can be compared among the healthy group of people. This paper provides a rigorous theoretical framework for this argument and study the validity of McNemar's test regardless of the conditional independence assumption. We derive McNemar's test statistic under the null hypothesis considering both assumptions of conditional independence and conditional dependence. We then perform power analyses to show how the result is affected by the amount of the conditional dependence under alternative hypothesis.

  16. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils.

    PubMed

    Lors, Christine; Ponge, Jean-François; Martínez Aldaya, Maite; Damidot, Denis

    2010-08-01

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.

    PubMed

    Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-07-01

    To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no relationship between variability and sensitivity with FDT2 (P = 0.46). In comparison with SAP, FDT2 exhibited narrower test-retest intervals at test locations with lower sensitivity (SAP thresholds <25 dB). A comparison of the total and pattern deviation maps between both techniques showed that the total deviation analyses of FDT2 may slightly underestimate the visual field loss apparent with SAP. However, the pattern-deviation maps of both instruments agreed well with each other. The test-retest variability of FDT2 is uniform over the measurement range of the instrument. These properties may provide advantages for the monitoring of patients with glaucoma that should be investigated in longitudinal studies.

  18. Genetic Variation in Taste Sensitivity to Sugars in Drosophila melanogaster.

    PubMed

    Uchizono, Shun; Tanimura, Teiichi

    2017-05-01

    Taste sensitivity plays a major role in controlling feeding behavior, and alterations in feeding habit induced by changes in taste sensitivity can drive speciation. We investigated variability in taste preferences in wild-derived inbred lines from the Drosophila melanogaster Genetic Reference Panel. Preferences for different sugars, which are essential nutrients for fruit flies, were assessed using two-choice preference tests that paired glucose with fructose, sucrose, or trehalose. The two-choice tests revealed that individual lines have differential and widely variable sugar preferences, and that sugar taste sensitivity is polygenic in the inbred population tested. We focused on 2 strains that exhibited opposing preferences for glucose and fructose, and performed proboscis extension reflex tests and electrophysiological recordings on taste sensilla upon exposure to fructose and glucose. The results indicated that taste sensitivity to fructose is dimorphic between the 2 lines. Genetic analysis showed that high sensitivity to fructose is autosomal dominant over low sensitivity, and that multiple loci on chromosomes 2 and 3 influence sensitivity. Further genetic complementation tests for fructose sensitivity on putative gustatory receptor (Gr) genes for sugars suggested that the Gr64a-Gr64f locus, not the fructose receptor gene Gr43a, might contribute to the dimorphic sensitivity to fructose between the 2 lines. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  20. Studies on strain sensitivity of Trichomonas vaginalis to metronidazole.

    PubMed Central

    Meingassner, J G; Havelec, L; Mieth, H

    1978-01-01

    Ninety-four strains of Trichomonas vaginalis isolated from unselected patients in Vienna during the period from November 1975 to November 1975 were subjected to sensitivity tests against metronidazole in vitro and in vivo. Nearly 90% of the isolates examined showed in vitro growth inhibition at concentrations of 0.4 to 1.6 microgram metronidazole/ml and only about 10% at concentrations of less than 0.4 microgram/ml. All isolates showed some inhibition of growth after incubation for 48 hours with 3.2 microgram metroidazole/ml. Tests on treatment carried out on experimentally infected mice revealed that all strains of T. vaginalis examined were sensitive to metronidazole (MDE: less than 3 x 35 mg/kg peroral). PMID:305807

  1. Spectral Sensitivity of the ctenid spider Cupiennius salei Keys

    PubMed Central

    Zopf, Lydia M.; Schmid, Axel; Fredman, David; Eriksson, Bo Joakim

    2014-01-01

    Summary The spectral sensitivity of adult male Cupiennius salei Keys, a nocturnal hunting spider, was studied in a behavioural test. As known from earlier behavioural tests, C. salei walks towards a black target presented in front of a white background. In this study a black target (size 42 × 70 cm) was presented in a white arena illuminated by monochromatic light in the range of 365 to 695 nm using 19 monochromatic filters (HW in the range of 6 – 10 nm). In the first trial, the transmission of the optical filters was between 40 % and 80%. In a second trial the transmission was reduced to 5%, using a neutral density filter. At the high intensity the spiders showed a spectral sensivity in the range from 380 to 670 nm. In the second trial the animals only showed directed walks if the illumination was in the range of 449 to 599 nm, indicating a lower sensitivity at the margins of the spectral sensitivity. In previous intracellular recordings, the measured spectral sensitivity was between 320 and 620 nm. Interestingly, these results do not completely match the behaviourally tested spectral sensitivity of the photoreceptors, where the sensitivity range is shifted to longer wavelengths. In order to investigate the molecular background of spectral sensitivity, we searched for opsin genes in C. salei. We found three visual opsins that correspond to UV and middle to long wavelength sensitive opsins as described for jumping spiders. PMID:23948480

  2. Trillium 360 Seismometer Initial Test Results

    NASA Astrophysics Data System (ADS)

    Bainbridge, Geoffrey; Devanney, Peter; Upadhyaya, Sarvesh

    2017-04-01

    Test results for Trillium 360 show this seismometer can resolve the Peterson New Low Noise Model down to 300 seconds period. This has been confirmed at multiple sites: Pinon Flat (California), Albuquerque Seismological Laboratory (New Mexico) and Nanometrics (Ottawa, Canada). The Pinon Flat deployment captured the March 2, 2016 Mw=7.9 Indonesian event and showed a response coherent with reference sensors including an STS-1 at periods down to 0.0015 Hz. At frequencies below 0.0015 Hz the reference sensors showed a noncoherent spurious response, i.e. noise in the presence of signal, whereas the Trillium 360 was relatively unaffected. Magnetic sensitivity has been measured to be 0.01 m/s^2/T in two independent tests at ASL and Nanometrics. Temperature sensitivity is 3*10^-4 m/s^2/T. This combination of low sensitivity to both magnetic field and temperature is achieved through magnetic shielding which resolves the side effect of magnetic sensitivity in temperature-compensated ferromagnetic spring alloys. The T360 seismometer components are sufficiently miniaturized for deployment in a borehole. This enables low-noise performance even in an urban environment with thick sediments (at Nanometrics, Ottawa) since the seismometer can be emplaced in bedrock below surface sediments and away from surface noise.

  3. Determination of ABO blood grouping and Rhesus factor from tooth material.

    PubMed

    Kumar, Pooja Vijay; Vanishree, M; Anila, K; Hunasgi, Santosh; Suryadevra, Sri Sujan; Kardalkar, Swetha

    2016-01-01

    The aim of the study was to determine blood groups and Rhesus factor from dentin and pulp using absorption-elution (AE) technique in different time periods at 0, 3, 6, 9 and 12 months, respectively. A total of 150 cases, 30 patients each at 0, 3, 6, 9 and 12 months were included in the study. The samples consisted of males and females with age ranging 13-60 years. Patient's blood group was checked and was considered as "control." The dentin and pulp of extracted teeth were tested for the presence of ABO/Rh antigen, at respective time periods by AE technique. Data were analyzed in proportion. For comparison, Chi-square test or Fisher's exact test was used for the small sample. Blood group antigens of ABO and Rh factor were detected in dentin and pulp up to 12 months. For both ABO and Rh factor, dentin and pulp showed 100% sensitivity for the samples tested at 0 month and showed a gradual decrease in the sensitivity as time period increased. The sensitivity of pulp was better than dentin for both the blood grouping systems and ABO blood group antigens were better detected than Rh antigens. In dentin and pulp, the antigens of ABO and Rh factor were detected up to 12 months but showed a progressive decrease in the antigenicity as the time period increased. When compared the results obtained of dentin and pulp in ABO and Rh factor grouping showed similar results with no statistical significance. The sensitivity of ABO blood grouping was better than Rh factor blood grouping and showed a statistically significant result.

  4. A dose-response study of separate and combined effects of the serotonin agonist 8-OH-DPAT and the dopamine agonist quinpirole on locomotor sensitization, cross-sensitization, and conditioned activity.

    PubMed

    Johnson, Eric F; Szechtman, Henry

    2016-08-01

    Chronic treatment with the dopamine D2/D3 agonist, quinpirole, or the serotonin 1A agonist, 8-hydroxy-2-(di-n-propylamino)-tetralin (8-OH-DPAT), induces behavioral sensitization. It is not known whether both drugs produce sensitization through a shared mechanism. Here, we examine whether quinpirole and 8-OH-DPAT show cross-sensitization and impact sensitization, as would be expected from shared mechanisms. Male rats (N=208) were assigned randomly to 16 groups formed by crossing four doses of quinpirole (0, 0.03125, 0.0625, or 0.125 mg/kg) with four doses of 8-OH-DPAT (0, 0.03125, 0.625, or 0.125 mg/kg). After a course of 10 drug treatments administered twice per week in locomotor activity chambers, all groups were challenged on separate tests with quinpirole (0.1 mg/kg), 8-OH-DPAT (0.1 mg/kg), or saline, and locomotor activity was evaluated. Challenge tests with quinpirole and 8-OHDPAT showed no cross-sensitization between the drugs. Chronic quinpirole (0.125 mg/kg) administration induced a sensitized quinpirole response that was attenuated dose-dependently by chronic 8-OH-DPAT cotreatment. Cotreatment with quinpirole (0.0625 mg/kg) and 8-OH-DPAT (all doses) induced quinpirole sensitization. Chronic 8-OH-DPAT (0.125 mg/kg) induced a sensitized 8-OHDPAT response that was prevented by chronic cotreatment with the lowest but not the highest dose of quinpirole. Cotreatment with 8-OHDPAT (0.0625) and quinpirole (0.125 mg/kg) induced sensitization to 8-OH-DPAT. The saline challenge test showed elevated locomotor activity in chronic quinpirole (0.125 mg/kg) and 8-OHDPAT (0.0625, 0.125 mg/kg) alone groups, and in seven of nine cotreated groups. The absence of cross-sensitization suggests separate mechanisms of sensitization to quinpirole and 8-OH-DPAT. Cotreatment effects suggest that induction of sensitization can be modulated by serotonin 1A and D2/D3 activity.

  5. Enhanced olfactory sensitivity in autism spectrum conditions.

    PubMed

    Ashwin, Chris; Chapman, Emma; Howells, Jessica; Rhydderch, Danielle; Walker, Ian; Baron-Cohen, Simon

    2014-01-01

    People with autism spectrum conditions (ASC) report heightened olfaction. Previous sensory experiments in people with ASC have reported hypersensitivity across visual, tactile, and auditory domains, but not olfaction. The aims of the present study were to investigate olfactory sensitivity in ASC, and to test the association of sensitivity to autistic traits. We recruited 17 adult males diagnosed with ASC and 17 typical adult male controls and tested their olfactory sensitivity using the Alcohol Sniff Test (AST), a standardised clinical evaluation of olfactory detection. The AST involves varying the distance between subject and stimulus until an odour is barely detected. Participants with ASC also completed the Autism Spectrum Quotient (AQ) as a measure of autism traits. The ASC group detected the odour at a mean distance of 24.1 cm (SD =11.5) from the nose, compared to the control group, who detected it at a significantly shorter mean distance of 14.4 cm (SD =5.9). Detection distance was independent of age and IQ for both groups, but showed a significant positive correlation with autistic traits in the ASC group (r =0.522). This is the first experimental demonstration, as far as the authors are aware, of superior olfactory perception in ASC and showing that greater olfactory sensitivity is correlated with a higher number of autistic traits. This is consistent with results from previous findings showing hypersensitivity in other sensory domains and may help explain anecdotal and questionnaire accounts of heightened olfactory sensitivity in ASC. Results are discussed in terms of possible underlying neurophysiology.

  6. Prevalence of pollen sensitization in younger children who have asthma.

    PubMed

    Ogershok, Paul R; Warner, Daniel J; Hogan, Mary Beth; Wilson, Nevin W

    2007-01-01

    It is commonly believed that young children are incapable of pollen sensitization; therefore, skin testing usually is not performed to these allergens. The purpose of this study was to identify the frequency of positive skin tests to outdoor allergens among younger children who have asthma. Patients who have asthma, aged 6 months to 10 years, were evaluated for pollen sensitization over a 10-year period. Skin-prick testing was performed to relevant individual aeroallergens including trees, grasses, and weeds. Testing for perennial indoor allergens such as dust mites, cats, dogs, cockroaches, and molds was performed also. A total of 687 children with asthma were evaluated. No child <12 months old was sensitized to pollens. Children between 12 and 24 months of age had a 29% incidence of pollen sensitization. Three-year-old children were as likely to be skin test positive to pollen as an indoor allergen. Notably, 49% of 3- and 4-year olds were sensitized to outdoor allergens. Primary sensitizing pollens in this age group were short ragweed, box elder, and June grass. In this population, pollen sensitization was not related to tobacco or wood smoke exposure. Although it is widely believed that young children with asthma are most commonly allergic to indoor allergens, almost 40% of our 1- to 3-year old children with asthma showed IgE-mediated sensitivity to outdoor allergens. Pediatric allergists should consider performing skin-prick testing to their local common aeroallergens in young children with asthma and seasonal symptoms.

  7. Localized periorbital edema as a clinical manifestation of sulfite sensitivity.

    PubMed Central

    Park, H. S.; Nahm, D.

    1996-01-01

    Sulfite is commonly used in pharmaceuticals as a preservative. We report a unique clinical presentation of localized periorbital edema on the left eye after administration of sulfite-containing dexamethasone. The patient's sulfite sensitivity was confirmed by sulfite oral provocation test: periorbital edema on the same site developed after ingestion of 200 mg sodium bisulfite. She was non-atopic and did not complain of any respiratory symptoms. Allergy skin prick test with 100 mg/ml sodium bisulfite showed a negative result. She also has aspirin-sensitive urticaria which was confirmed by oral provocation test. In conclusion, sulfite can induce a localized periorbital edema, an uncommon manifestation in sensitive patients. Further investigations are needed to clarify the pathogenetic mechanisms. PMID:8878807

  8. Antihyperglycemic effect of syringaldehyde in streptozotocin-induced diabetic rats.

    PubMed

    Huang, Chia-Hsin; Chen, Mei-Fen; Chung, Hsien-Hui; Cheng, Juei-Tang

    2012-08-24

    The antihyperglycemic effect of syringaldehyde (1), purified from the stems of Hibiscus taiwanensis, was investigated in streptozotocin-induced diabetic rats (STZ-diabetic rats) showing type-1 like diabetes mellitus. Bolus intravenous injection of 1 showed antihyperglycemic activity in a dose-dependent manner in STZ-diabetic rats. An effective dose of 7.2 mg/kg of 1 attenuated significantly the increase of plasma glucose induced by an intravenous glucose challenge test in normal rats. A glucose uptake test showed that 1 exhibits an increase of glucose uptake activity in a concentration-related manner. Moreover, an effect by 1 was shown for insulin sensitivity in STZ-diabetic rats. The compound was found to increase insulin sensitivity in STZ-diabetic rats. These results suggest that syringaldehyde (1) can increase glucose utilization and insulin sensitivity to lower plasma glucose in diabetic rats.

  9. Local lymph node assay (LLNA): comparison of different protocols by testing skin-sensitizing epoxy resin system components.

    PubMed

    Gamer, Armin O; Nies, Eberhard; Vohr, Hans-Werner

    2008-12-01

    Thirteen epoxy resin system components were tested in the LLNA with regard to their sensitizing potency. Lymph node stimulation was quantified not only by measuring the incorporation of [3H]-thymidine into the ear lymph nodes but also the counts of cells recovered from these organs. Equivalent figures were obtained with both endpoints used for the evaluation of lymph node cell proliferation if the reference stimulation indices were adjusted. When dissolved in acetone, all test substances showed skin-sensitizing potential, mainly on the boundary between "strong" and "moderate" according to common potency evaluation schemes. Replacing acetone with acetone/olive oil (4:1) as a vehicle for four selected test items, resulted in considerably lower estimated concentrations for sensitization induction. The challenges in comparing the results obtained by different LLNA variations are discussed.

  10. Sensitization and cross-reactivity patterns of contact allergy to diisocyanates and corresponding amines: investigation of diphenylmethane-4,4'-diisocyanate, diphenylmethane-4,4'-diamine, dicyclohexylmethane-4,4'-diisocyanate, and dicylohexylmethane-4,4'-diamine.

    PubMed

    Hamada, Haneen; Bruze, Magnus; Zimerson, Erik; Isaksson, Marléne; Engfeldt, Malin

    2017-10-01

    Isocyanates are used in polyurethane production. Dermal exposure to isocyanates can induce contact allergy. The most common isocyanate is diphenylmethane diisocyanate used for industrial purposes. The isomer diphenylmethane-4,4'-diisocyanate (4,4'-MDI) is used in patch testing. Diphenylmethane-4,4'-diamine (4,4'-MDA) is its corresponding amine. Concurrent reactions to 4,4'-MDI and 4,4'-MDA have been reported, as have concurrent reactions to 4,4'-MDI and dicyclohexylmethane-4,4'-diisocyanate (4,4'-DMDI). To investigate the sensitization capacities and the cross-reactivity of 4,4'-MDI, 4,4'-MDA, 4,4'-DMDI, and dicyclohexylmethane-4,4'-diamine (4,4'-DMDA). The guinea-pig maximization test (GPMT) was used. The GPMT showed sensitizing capacities for all investigated substances: 4,4'-MDI, 4,4'-MDA, 4,4'-DMDI, and 4,4'-DMDA (all p < 0.001). 4,4'-MDI-sensitized animals showed cross-reactivity to 4,4'-MDA (p < 0.001) and 4,4'-DMDI (all p < 0.05). 4,4'-MDA-sensitized animals showed cross-reactivity to 4,4'-DMDA (p = 0.008). All of the investigated substances were shown to be strong sensitizers. Animals sensitized to 4,4'-MDI showed cross-reactivity to 4,4'-MDA and 4,4'-DMDI, supporting previous findings in the literature. The aromatic amine 4,4'-MDA showed cross-reactivity to the aliphatic amine 4,4'-DMDA. © 2017 The Authors. Contact Dermatitis published by John Wiley & Sons Ltd.

  11. Clinical color vision testing and correlation with visual function.

    PubMed

    Zhao, Jiawei; Davé, Sarita B; Wang, Jiangxia; Subramanian, Prem S

    2015-09-01

    To determine if Hardy-Rand-Rittler (H-R-R) and Ishihara testing are accurate estimates of color vision in subjects with acquired visual dysfunction. Assessment of diagnostic tools. Twenty-two subjects with optic neuropathy (aged 18-65) and 18 control subjects were recruited prospectively from an outpatient clinic. Individuals with visual acuity (VA) <20/200 or with congenital color blindness were excluded. All subjects underwent a comprehensive eye examination including VA, color vision, and contrast sensitivity testing. Color vision was assessed using H-R-R and Ishihara plates and Farnsworth D-15 (D-15) discs. D-15 is the accepted standard for detecting and classifying color vision deficits. Contrast sensitivity was measured using Pelli-Robson contrast sensitivity charts. No relationship was found between H-R-R and D-15 scores (P = .477). H-R-R score and contrast sensitivity were positively correlated (P = .003). On multivariate analysis, contrast sensitivity (β = 8.61, P < .001) and VA (β = 2.01, P = .022) both showed association with H-R-R scores. Similar to H-R-R, Ishihara score did not correlate with D-15 score (P = .973), but on multivariate analysis was related to contrast sensitivity (β = 8.69, P < .001). H-R-R and Ishihara scores had an equivalent relationship with contrast sensitivity (P = .069). Neither H-R-R nor Ishihara testing appears to assess color identification in patients with optic neuropathy. Both H-R-R and Ishihara testing are correlated with contrast sensitivity, and these tests may be useful clinical surrogates for contrast sensitivity testing. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Absolute auditory thresholds in three Old World monkey species (Cercopithecus aethiops, C. neglectus, Macaca fuscata) and humans (Homo sapiens).

    PubMed

    Owren, M J; Hopp, S L; Sinnott, J M; Petersen, M R

    1988-06-01

    We investigated the absolute auditory sensitivities of three monkey species (Cercopithecus aethiops, C. neglectus, and Macaca fuscata) and humans (Homo sapiens). Results indicated that species-typical variation exists in these primates. Vervets, which have the smallest interaural distance of the species that we tested, exhibited the greatest high-frequency sensitivity. This result is consistent with Masterton, Heffner, and Ravizza's (1969) observations that head size and high-frequency acuity are inversely correlated in mammals. Vervets were also the most sensitive in the middle frequency range. Furthermore, we found that de Brazza's monkeys, though they produce a specialized, low-pitched boom call, did not show the enhanced low-frequency sensitivity that Brown and Waser (1984) showed for blue monkeys (C. mitis), a species with a similar sound. This discrepancy may be related to differences in the acoustics of the respective habitats of these animals or in the way their boom calls are used. The acuity of Japanese monkeys was found to closely resemble that of rhesus macaques (M. mulatta) that were tested in previous studies. Finally, humans tested in the same apparatus exhibited normative sensitivities. These subjects responded more readily to low frequencies than did the monkeys but rapidly became less sensitive in the high ranges.

  13. On the Piezoelectric Detection of Guided Ultrasonic Waves

    PubMed Central

    2017-01-01

    In order to quantify the wave motion of guided ultrasonic waves, the characteristics of piezoelectric detectors, or ultrasonic transducers and acoustic emission sensors, have been evaluated systematically. Such guided waves are widely used in structural health monitoring and nondestructive evaluation, but methods of calibrating piezoelectric detectors have been inadequate. This study relied on laser interferometry for the base displacement measurement of bar waves, from which eight different guided wave test set-ups are developed with known wave motion using piezoelectric transmitters. Both plates and bars of 12.7 and 6.4 mm thickness were used as wave propagation media. The upper frequency limit was 2 MHz. Output of guided wave detectors were obtained on the test set-ups and their receiving sensitivities were characterized and averaged. While each sensitivity spectrum was noisy for a detector, the averaged spectrum showed a good convergence to a unique receiving sensitivity. Twelve detectors were evaluated and their sensitivity spectra determined in absolute units. Generally, these showed rapidly dropping sensitivity with increasing frequency due to waveform cancellation on their sensing areas. This effect contributed to vastly different sensitivities to guided wave and to normally incident wave for each one of the 12 detectors tested. Various other effects are discussed and recommendations on methods of implementing the approach developed are provided. PMID:29156579

  14. Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.

    PubMed

    Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N

    2007-05-01

    This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.

  15. Differential housing and novelty response: Protection and risk from locomotor sensitization

    PubMed Central

    Garcia, Erik J.; Haddon, Tara N.; Saucier, Donald A.; Cain, Mary E.

    2017-01-01

    High novelty seeking increases the risk for drug experimentation and locomotor sensitization. Locomotor sensitization to psychostimulants is thought to reflect neurological adaptations that promote the transition to compulsive drug taking. Rats reared in enrichment (EC) show less locomotor sensitization when compared to rats reared in isolation (IC) or standard conditions (SC). The current research study was designed to test if novelty response contributed locomotor sensitization and more importantly, if the different housing environments could change the novelty response to protect against the development of locomotor sensitization in both adolescence and adulthood. Experiment 1: rats were tested for their response to novelty using the inescapable novelty test (IEN) and pseudorandomly assigned to enriched (EC), isolated (IC), or standard (SC) housing conditions for 30 days. After housing, they were tested with IEN. Rats were then administered amphetamine (0.5 mg/kg) or saline and locomotor activity was measured followed by a sensitization test 14 days later. Experiment 2: rats were tested in the IEN test early adulthood and given five administrations of amphetamine (0.3 mg/kg) or saline and then either stayed in or switched housing environments for 30 days. Rats were then re-tested in the IEN test in late adulthood and administered five more injections of their respective treatments and tested for locomotor sensitization. Results indicate that IC and SC increased the response to novelty. EC housing decreased locomotor response to amphetamine and saline, and SC housing increased the locomotor response to amphetamine. Mediation results indicated that the late adult novelty response fully mediates the locomotor response to amphetamine and saline, while the early adulthood novelty response did not. Conclusions Differential housing changes novelty and amphetamine locomotor response. Novelty response is altered into adulthood and provides evidence that enrichment can be used to reduce drug vulnerability. PMID:28108176

  16. Sensitivity of Ethiopian aquatic macroinvertebrates to the pesticides endosulfan and diazinon, compared to literature data.

    PubMed

    Teklu, Berhan M; Retta, Negussie; Van den Brink, Paul J

    2016-08-01

    The aims of the present study were to present a methodology for toxicity tests that can be used when analytical resources to verify the test concentrations are limited, and to evaluate whether the sensitivity of a limited number of Ethiopian species to pesticides differs from literature values for, mainly, temperate species. Acute toxicity tests were performed using three Ethiopian aquatic invertebrate species, one crustacean (Diaphanosoma brachyurum) and two insects (Anopheles pharoensis and Culex pipiens) and using the pesticides endosulfan and diazinon. All species-pesticide combinations were tested in duplicate to estimate the consistency, i.e. the intra-laboratory variation, in test results. Daphnia magna was tested as well to allow the test results to be compared directly with values from the literature. Results indicate that the differences between the EC50s obtained for D. magna in this study and those reported in the literature were less than a factor of 2. This indicates that the methodology used is able to provide credible toxicity values. The results of the duplicated tests showed intra-laboratory variation in EC50 values of up to a factor of 3, with one test showing a difference of a factor of 6 at 48 h. Comparison with available literature results for arthropod species using species sensitivity distributions indicated that the test results obtained in this study fit well in the log-normal distribution of the literature values. We conclude that the methodology of performing multiple tests to check for consistency of test results and performing tests with D. magna for comparison with literature values to check for accuracy is able to provide reliable effect threshold levels and that the tested Ethiopian species did not differ in sensitivity from the arthropod species reported on in the literature.

  17. Correlation of Radiological and Endoscopic Findings in Patients Presenting with Dysphagia.

    PubMed

    Sachdeva, Kavita; Kaul, Vineet

    2017-03-01

    Dysphagia is a common symptom with diverse etiology in otolaryngology. In the present study clinicopathological, radiological and endoscopic evaluation of patients was done in a tertiary care hospital in patients presenting with dysphagia. A prospective nonrandomized observational study was carried out on total of 80 cases having dysphagia during March 2015 to August 2016. In the present study, out of 80 patients, youngest case was a three years old child while oldest case was an 85 years old female. The mean age was 48.3 ± 20.3 years. The majority of cases were in age group 41-59 years (35%). Male to female ratio was 2.33:1. The mean duration of illness was 15.44 weeks. 15% of patients had absolute dysphagia. For detecting the lesion, Barium swallow study (BSS) showed a total sensitivity of 49.05% (n = 53), Computerised Tomography (CT) showed a total sensitivity of 85.70% (n = 49), plain skiagram neck & chest showed a total sensitivity of 88.88% (n = 9) and endoscopy was the most sensitive test overall as it showed a total sensitivity of 98.75% (n = 80). No complications were reported with either rigid or flexible endoscopy. Dysphagia is a common presenting complaint in otolaryngology with cases coming directly or being referred from other specialities. Males are more commonly affected than females and incidence of malignancy increases with age. Endoscopy can become the first screening test in dysphagia due to its high sensitivity and low risk of complications, with radiological tests being done in an adjunct manner.

  18. Evaluation of the Addenbrooke's Cognitive Examination's validity in a brain injury rehabilitation setting.

    PubMed

    Gaber, Tarek A-Z K

    2008-07-01

    Several reports have warned of the Mini Mental State Examination's (MMSE) inability to detect gross memory and high executive impairments. Addenbrooke's Cognitive Examination-Revised (ACE-R) has gained enormous popularity in dementia screening as it addresses the main shortcomings of MMSE. This study aimed at evaluating the use of ACE-R and to establish its sensitivity compared to MMSE in a cohort of brain injury patients. ACE-R was administered to a cohort of chronic brain injury patients. All patients had a cognitive impairment which was severe enough to prevent them working or studying. Patients with significant mental health, sensory, communication or physical impairments were excluded. Thirty-six patients were recruited, 31 males with a mean age of 37 years. For an upper cut-off value of 27/30 for MMSE and 88/100 for ACE-R, their sensitivities were 36% and 72%, respectively. For a lower cut-off value of 24/30 and 82/100 the tests sensitivities were 11% and 56%, respectively. Analysis of the ACE-R sub-tests indicated that memory and verbal fluency sub-tests showed the most dramatic impairment. MMSE is insensitive as a screening test in brain injury patients. The results show ACE-R to be a sensitive, easily administered test.

  19. Antimicrobial susceptibility pattern in nosocomial infections caused by Acinetobacter species in Asir Region, Saudi Arabia.

    PubMed

    Abdalla, Nazar M; Osman, Amani A; Haimour, Waleed O; Sarhan, Mohammed A A; Mohammed, Mohammed N; Zyad, Eyhab M; Al-Ghtani, Abdalla M

    2013-03-15

    This study aimed at evaluating the sensitivity of antibiotics towards nosocomial infections caused by Acinetobacter species. The study took place during the period Dec. 2011- Dec. 2012 at Assir Central Hospital in collaboration with the department of microbiology, college of medicine, King Khalid University, Abha. A prospective study involving 150 patients presented with nosocomial infections due to Acinetobacter species detected by bacteriological tests; direct microscopy, culture in blood agar media, fermentation test in MacConkey media and MIC (minimum inhibitory concentration) for antibiotics sensitivity using Muller Hinton media and Chemical test using API 20. A 150 nosocomial infections in this study showed gram-negative coccobacilli, non motile, glucose-negative fermentor and oxidase negative. All isolates showed 100% sensitivity to: Imipramine, Meropenem, Colistin. From the rest of tested antibiotics the higher resistant ones were; Nitrofurantoin 87% and Cefoxitin 85%. The least resistant antibiotics; Imipenem 3% and Ticarcillin 7%. While variable resistance in the rest of tested antimicrobials. A 47 patients (31.3%) have used antibiotics prior to this study. The high rate of usage occurred in elder patients. The frequency of Acinetobacter calcoaceticus baumannii complex multi-drugs resistance ABCMDR is rising including almost all commonly used antibiotics. Only few antibiotics exert 100% sensitivity towards these bacteria.

  20. Physical examination for lumbar radiculopathy due to disc herniation in patients with low-back pain.

    PubMed

    van der Windt, Daniëlle Awm; Simons, Emmanuel; Riphagen, Ingrid I; Ammendolia, Carlo; Verhagen, Arianne P; Laslett, Mark; Devillé, Walter; Deyo, Rick A; Bouter, Lex M; de Vet, Henrica Cw; Aertgeerts, Bert

    2010-02-17

    Low-back pain with leg pain (sciatica) may be caused by a herniated intervertebral disc exerting pressure on the nerve root. Most patients will respond to conservative treatment, but in carefully selected patients, surgical discectomy may provide faster relief of symptoms. Primary care clinicians use patient history and physical examination to evaluate the likelihood of disc herniation and select patients for further imaging and possible surgery. (1) To assess the performance of tests performed during physical examination (alone or in combination) to identify radiculopathy due to lower lumbar disc herniation in patients with low-back pain and sciatica;(2) To assess the influence of sources of heterogeneity on diagnostic performance. We searched electronic databases for primary studies: PubMed (includes MEDLINE), EMBASE, and CINAHL, and (systematic) reviews: PubMed and Medion (all from earliest until 30 April 2008), and checked references of retrieved articles. We considered studies if they compared the results of tests performed during physical examination on patients with back pain with those of diagnostic imaging (MRI, CT, myelography) or findings at surgery. Two review authors assessed the quality of each publication with the QUADAS tool, and extracted details on patient and study design characteristics, index tests and reference standard, and the diagnostic two-by-two table. We presented information on sensitivities and specificities with 95% confidence intervals (95% CI) for all aspects of physical examination. Pooled estimates of sensitivity and specificity were computed for subsets of studies showing sufficient clinical and statistical homogeneity. We included 16 cohort studies (median N = 126, range 71 to 2504) and three case control studies (38 to100 cases). Only one study was carried out in a primary care population. When used in isolation, diagnostic performance of most physical tests (scoliosis, paresis or muscle weakness, muscle wasting, impaired reflexes, sensory deficits) was poor. Some tests (forward flexion, hyper-extension test, and slump test) performed slightly better, but the number of studies was small. In the one primary care study, most tests showed higher specificity and lower sensitivity compared to other settings.Most studies assessed the Straight Leg Raising (SLR) test. In surgical populations, characterized by a high prevalence of disc herniation (58% to 98%), the SLR showed high sensitivity (pooled estimate 0.92, 95% CI: 0.87 to 0.95) with widely varying specificity (0.10 to 1.00, pooled estimate 0.28, 95% CI: 0.18 to 0.40). Results of studies using imaging showed more heterogeneity and poorer sensitivity. The crossed SLR showed high specificity (pooled estimate 0.90, 95% CI: 0.85 to 0.94) with consistently low sensitivity (pooled estimate 0.28, 95% CI: 0.22 to 0.35).Combining positive test results increased the specificity of physical tests, but few studies presented data on test combinations. When used in isolation, current evidence indicates poor diagnostic performance of most physical tests used to identify lumbar disc herniation. However, most findings arise from surgical populations and may not apply to primary care or non-selected populations. Better performance may be obtained when tests are combined.

  1. Amperometric Enzyme-based Gas Sensor for Formaldehyde: Impact of Possible Interferences

    PubMed Central

    Achmann, Sabine; Hämmerle, Martin; Moos, Ralf

    2008-01-01

    In this work, cross-sensitivities and environmental influences on the sensitivity and the functionality of an enzyme-based amperometric sensor system for the direct detection of formaldehyde from the gas phase are studied. The sensor shows a linear response curve for formaldehyde in the tested range (0 - 15 vppm) with a sensitivity of 1.9 μA/ppm and a detection limit of about 130 ppb. Cross-sensitivities by environmental gases like CO2, CO, NO, H2, and vapors of organic solvents like methanol and ethanol are evaluated as well as temperature and humidity influences on the sensor system. The sensor showed neither significant signal to CO, H2, methanol or ethanol nor to variations in the humidity of the test gas. As expected, temperature variations had the biggest influence on the sensor sensitivity with variations in the sensor signal of up to 10 % of the signal for 5 vppm CH2O in the range of 25 - 30 °C. PMID:27879770

  2. Randomized clinical trial of the effect of NovaMin and CPP-ACPF in combination with dental bleaching.

    PubMed

    Alexandrino, Larissa Dias; Alencar, Cristiane de Melo; Silveira, Ana Daniela Silva da; Alves, Eliane Bemerguy; Silva, Cecy Martins

    2017-01-01

    This randomized, controlled, double-blind clinical study evaluated the effect of calcium sodium phosphosilicate (NovaMin) and casein phosphopeptide-amorphous calcium phosphate with fluoride (CPP-ACPF) on the prevention of post-operative sensitivity and on the effects of clinical bleaching treatment. Sixty volunteers were selected according to inclusion and exclusion criteria and were randomly assigned into three groups (n=20): CG (control group) patients, who were treated with 35% hydrogen peroxide; NOVAG (NovaMin group) patients, who were treated with 35% hydrogen peroxide followed by the application of NovaMin; and CPPG (CPP group) patients, who were treated with 35% hydrogen peroxide followed by the application of CPP-ACPF. Both bioactive agents were applied for five minutes. An evaporative stimulus associated with a modified visual scale was used to analyze sensitivity 24 hours after each bleaching session. The color evaluation was performed on the maxillary central incisors using a spectrophotometer. Associations between the intervention group, bleaching session, and reported sensitivity were tested using Chi-square partitioning. Color change values (ΔE) were analyzed using analysis of variance (ANOVA). The significance level used for both tests was 5%. In the intragroup assessment, the Friedman test showed that only the CPP-ACPF group showed no statistically significant difference (p<0.05) between baseline and first bleaching session. In the intergroup assessment, the Kruskal-Wallis test showed that the CPPG had less postoperative sensitivity after the first session, when compared to the other groups (p<0.05). Color change analysis (ΔE) showed a significant difference between the means obtained in the different bleaching sessions in all groups (p<0.05). This study showed that the combination of CPP-ACPF with 35% hydrogen peroxide significantly reduced post-operative sensitivity in the first session, compared with the other evaluated treatments. The association of CPP-ACPF and NovaMin did not affect the color change induced by tooth bleaching.

  3. Diagnosis and Treatment of Typhoid Fever and Associated Prevailing Drug Resistance in Northern Ethiopia.

    PubMed

    Wasihun, Araya Gebreyesus; Wlekidan, Letemichael Negash; Gebremariam, Senay Aregawi; Welderufael, Abadi Luel; Muthupandian, Saravanan; Haile, Tadesse Dejenie; Dejene, Tsehaye Asmelash

    2015-06-01

    To determine diagnostic value of the Widal test, treatment pattern of febrile patients and antimicrobial drug susceptibility pattern of blood isolates. Using cross sectional methods, blood samples were collected for culture and Widal test from 502 febrile outpatients attending Mekelle hospital and Mekelle health center with similar symptoms to typhoid. Sensitivity, specificity for anti-TH and anti-TO titers using culture confirmed typhoid fever cases, and Kappa agreement between Titer and slide Widal tests were calculated. Treatment pattern of patients and antimicrobial susceptibility pattern of the blood isolates was assessed. From the 502 febrile patients, 8(1.6%) of them had culture-proven typhoid fever. However, patients who have results indicative of recent infection by O and H antigens of the Widal slide agglutination test were 343 (68.5%), with specificity and sensitivity of 33% and 100%, respectively. Over prescription of antibiotics was seen by Widal slide test for Ciprofloxacin 268 (76.1%), Amoxicillin- Clavulanic acid 9(2.6%), Amoxicillin 8(2.4%) and Chloranphenicol 8(2.4%). Tube titer positivity was seen in 23(5.3%) patients with 75% sensitivity and 95.8% specificity. Widal slide and Tube titer tests showed poor agreement for both antigens (kappa=0.02 for O) and (Kappa=0.09 for H). A single anti-TH titer of ≥ 1:160 and anti-TO titer ≥ 1:80 higher in our study showed an indication for typhoid fever infection. Drug resistance pattern of blood isolates ranges from 0-89.7% for gram positive and 0-100% for Gram negative, with an overall multi-drug resistance rate of 61.7%. Patients were wrongly diagnosed and treated for typhoid fever by Widal test. The tube titration method was relatively good but still had poor sensitivity. Blood isolates showed multi drug resistance, which may be due to the indiscriminate prescription as seen in this study. Based on our results, the slide Widal test is not helpful in the diagnosis of typhoid, hence other tests with rapid, feasible, better sensitivity and specificity are urgently needed in Ethiopia. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Grating test of contrast sensitivity in patients with Minamata disease.

    PubMed Central

    Mukuno, K; Ishikawa, S; Okamura, R

    1981-01-01

    Thirty cases of Minamata disease caused by methyl mercury poisoning with the lesion mainly at the occipital cortex were selected and their spatial contrast sensitivity of vision was examined by the Arden grating chart. At the same time their visual acuity, visual field, and visual evoked cortical potential (VECP) were also investigated. In all cases the results of the Arden test indicated abnormality. Poor results were obtained at higher frequencies of the gratings. VECP elicited by grating pattern reversal stimulus was undertaken in 12 cases out of the 30. The results revealed abnormality almost equal to that shown by the Arden test. Seven out of the 12 cases showed no VECP response. The other 5, giving a response, showed abnormality: when the size of the grating became smaller at higher frequencies, the VECP paused or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement or was not recorded, whereas at low frequencies it was recorded. This finding was in good agreement with the results of the Arden test. Visual acuity and visual field tests were less sensitive in detecting abnormality. The Arden chart is a sensitive clinical tool for patients with lesions at the cerebral cortex. Furthermore, the test can be used for screening patients who may have come in contrast with organic mercury. PMID:7236573

  5. Polyethylene glycol as marker for nitrofurazone allergy: 20 years of experience from Turkey.

    PubMed

    Özkaya, Esen; Kılıç, Sıla

    2018-03-01

    Polyethylene glycols (PEGs) and propylene glycol (PG) are used as vehicles in various medicinal and cosmetic products. They are potential contact sensitizers, including low molecular weight PEGs in nitrofurazone preparations that are still widely used in Turkey. To investigate the prevalence of allergic contact dermatitis caused by PEG and PG in a relatively large group of patients in Turkey. In this retrospective, cross-sectional, single-centre study, 836 patients patch tested with PEG and PG between 1996 and 2015 were reviewed. Thirty-five patients (4.2%) showed positive patch test reactions to PEG, and 7 (0.8%) showed positive patch test reactions to PG, partly as late positive reactions with PEG. PEG sensitivity was almost exclusively related to nitrofurazone allergy. Patch test reactions to PG were currently relevant mainly with regard to the use of minoxidil, and antiherpetic or corticosteroid creams. Ten patients (25%) had concomitant contact allergies to various topical drugs containing mainly PEGs. PEG sensitivity seems to be a marker for contact allergy to topical nitrofurazone in Turkey. Nitrofurazone allergy appears to favour concomitant sensitization to PEG. We would suggest the inclusion of PEG in an extended baseline patch test series in Turkey. Late patch test readings are important to diagnose delayed positive reactions to PEG. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Sensitivity and specificity of the 3-item memory test in the assessment of post traumatic amnesia.

    PubMed

    Andriessen, Teuntje M J C; de Jong, Ben; Jacobs, Bram; van der Werf, Sieberen P; Vos, Pieter E

    2009-04-01

    To investigate how the type of stimulus (pictures or words) and the method of reproduction (free recall or recognition after a short or a long delay) affect the sensitivity and specificity of a 3-item memory test in the assessment of post traumatic amnesia (PTA). Daily testing was performed in 64 consecutively admitted traumatic brain injured patients, 22 orthopedically injured patients and 26 healthy controls until criteria for resolution of PTA were reached. Subjects were randomly assigned to a test with visual or verbal stimuli. Short delay reproduction was tested after an interval of 3-5 minutes, long delay reproduction was tested after 24 hours. Sensitivity and specificity were calculated over the first 4 test days. The 3-word test showed higher sensitivity than the 3-picture test, while specificity of the two tests was equally high. Free recall was a more effortful task than recognition for both patients and controls. In patients, a longer delay between registration and recall resulted in a significant decrease in the number of items reproduced. Presence of PTA is best assessed with a memory test that incorporates the free recall of words after a long delay.

  7. Development of a standardized battery of performance tests for the assessment of noise stress effects

    NASA Technical Reports Server (NTRS)

    Theologus, G. C.; Wheaton, G. R.; Mirabella, A.; Brahlek, R. E.

    1973-01-01

    A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

  8. Sensitivity of different Trypanosoma vivax specific primers for the diagnosis of livestock trypanosomosis using different DNA extraction methods.

    PubMed

    Gonzales, J L; Loza, A; Chacon, E

    2006-03-15

    There are several T. vivax specific primers developed for PCR diagnosis. Most of these primers were validated under different DNA extraction methods and study designs leading to heterogeneity of results. The objective of the present study was to validate PCR as a diagnostic test for T. vivax trypanosomosis by means of determining the test sensitivity of different published specific primers with different sample preparations. Four different DNA extraction methods were used to test the sensitivity of PCR with four different primer sets. DNA was extracted directly from whole blood samples, blood dried on filter papers or blood dried on FTA cards. The results showed that the sensitivity of PCR with each primer set was highly dependant of the sample preparation and DNA extraction method. The highest sensitivities for all the primers tested were determined using DNA extracted from whole blood samples, while the lowest sensitivities were obtained when DNA was extracted from filter paper preparations. To conclude, the obtained results are discussed and a protocol for diagnosis and surveillance for T. vivax trypanosomosis is recommended.

  9. Development of animal models and sandwich-ELISA tests to detect the allergenicity and antigenicity of fining agent residues in wines.

    PubMed

    Lifrani, Awatif; Dos Santos, Jacinthe; Dubarry, Michel; Rautureau, Michelle; Blachier, Francois; Tome, Daniel

    2009-01-28

    Food allergy can cause food-related anaphylaxis. Food allergen labeling is the principal means of protecting sensitized individuals. This motivated European Directive 2003/89 on the labeling of ingredients or additives that could trigger adverse reactions, which has been in effect since 2005. During this study, we developed animal models with allergy to ovalbumin, caseinate, and isinglass in order to be able to detect fining agent residues that could induce anaphylactic reactions in sensitized mice. The second aim of the study was to design sandwich ELISA tests specific to each fining agent in order to detect their residue antigenicity, both during wine processing and in commercially available bottled wines. Sensitized mice and sandwich ELISA methods were established to test a vast panel of wines. The results showed that although they were positive to our highly sensitive sandwich-ELISA tests, some commercially available wines are not allergenic in sensitized mice. Commercially available bottled wines made using standardized processes, fining, maturation, and filtration, do not therefore represent any risk of anaphylactic reactions in sensitized mice.

  10. [Sensitization to chymopapain in patients treated with chemonucleolysis].

    PubMed

    García-Ortega, P; Ramírez Ferreiras, W; Sancho, A; Urías, S; Cisteró, A

    1991-03-23

    Chemonucleolysis (intradisk administration of chymopapain) is a procedure to treat intervertebral disk hernia. Recently, its use has been questioned due to the development of anaphylactic reactions in patients sensitized to chymopapain. The prevalence of sensitization to chymopapain has been evaluated before and after chemonucleolysis, and the possibility to establish risk groups through the allergy history has been assessed. 104 consecutive patients who were candidates to chemonucleolysis were evaluated with an allergy questionnaire, cutaneous tests to aeroallergens and to chymopapain, and chymopapain-specific IgE. The two latter tests were repeated one month after chemonucleolysis. Only 2 patients (1.9%) showed evidence of chymopapain sensitization before the procedure. Sixteen patients (16%) were sensitized after chemonucleolysis. None of the possible risk factors evaluated in the allergy questionnaire (atopy, drug allergy, papaya occupational exposure or use of additives, cosmetics or drugs containing papaine) were significantly related with the risk of sensitization to chymopapain. The prevalence of chymopapain sensitization in the study group was low. The allergy questionnaire (atopy, drug allergy, use of papaya, occupational history did not identify sensitized patients. Cutaneous tests and specific IgE are the best method to detect chymopapain sensitization. The remarkable rate of sensitization after chemonucleolysis may partially limit the usefulness of the procedure.

  11. Alternative methods for toxicity assessments in fish: comparison of the fish embryo toxicity and the larval growth and survival tests in zebrafish and fathead minnows.

    PubMed

    Jeffries, Marlo K Sellin; Stultz, Amy E; Smith, Austin W; Rawlings, Jane M; Belanger, Scott E; Oris, James T

    2014-11-01

    An increased demand for chemical toxicity evaluations has resulted in the need for alternative testing strategies that address animal welfare concerns. The fish embryo toxicity (FET) test developed for zebrafish (Danio rerio) is one such alternative, and the application of the FET test to other species such as the fathead minnow (Pimephales promelas) has been proposed. In the present study, the performances of the FET test and the larval growth and survival (LGS; a standard toxicity testing method) test in zebrafish and fathead minnows were evaluated. This required that testing methods for the fathead minnow FET and zebrafish LGS tests be harmonized with existing test methods and that the performance of these testing strategies be evaluated by comparing the median lethal concentrations of 2 reference toxicants, 3,4-dicholoraniline and ammonia, obtained via each of the test types. The results showed that procedures for the zebrafish FET test can be adapted and applied to the fathead minnow. Differences in test sensitivity were observed for 3,4-dicholoraniline but not ammonia; therefore, conclusions regarding which test types offer the least or most sensitivity could not be made. Overall, these results show that the fathead minnow FET test has potential as an alternative toxicity testing strategy and that further analysis with other toxicants is warranted in an effort to better characterize the sensitivity and feasibility of this testing strategy. © 2014 SETAC.

  12. Can currently available non-animal methods detect pre and pro-haptens relevant for skin sensitization?

    PubMed

    Patlewicz, Grace; Casati, Silvia; Basketter, David A; Asturiol, David; Roberts, David W; Lepoittevin, Jean-Pierre; Worth, Andrew P; Aschberger, Karin

    2016-12-01

    Predictive testing to characterize substances for their skin sensitization potential has historically been based on animal tests such as the Local Lymph Node Assay (LLNA). In recent years, regulations in the cosmetics and chemicals sectors have provided strong impetus to develop non-animal alternatives. Three test methods have undergone OECD validation: the direct peptide reactivity assay (DPRA), the KeratinoSens™ and the human Cell Line Activation Test (h-CLAT). Whilst these methods perform relatively well in predicting LLNA results, a concern raised is their ability to predict chemicals that need activation to be sensitizing (pre- or pro-haptens). This current study reviewed an EURL ECVAM dataset of 127 substances for which information was available in the LLNA and three non-animal test methods. Twenty eight of the sensitizers needed to be activated, with the majority being pre-haptens. These were correctly identified by 1 or more of the test methods. Six substances were categorized exclusively as pro-haptens, but were correctly identified by at least one of the cell-based assays. The analysis here showed that skin metabolism was not likely to be a major consideration for assessing sensitization potential and that sensitizers requiring activation could be identified correctly using one or more of the current non-animal methods. Published by Elsevier Inc.

  13. Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea

    PubMed Central

    Portero, José-Luis; Rubio-Yuste, Maria; Descalzo, Miguel Angel; Raso, Jose; Lwanga, Magdalena; Obono, Jaquelina; Nseng, Gloria; Benito, Agustin; Cano, Jorge

    2010-01-01

    Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children. PMID:22332024

  14. Evaluation of a monoclonal antibody-based latex agglutination test for diagnosis of cryptococcosis: comparison with two tests using polyclonal antibodies.

    PubMed Central

    Temstet, A; Roux, P; Poirot, J L; Ronin, O; Dromer, F

    1992-01-01

    Cryptococcal antigen detection has become a routine biological test performed for patients with AIDS. The poor prognosis of cryptococcosis explains the need for reliable tests. We evaluated the performances of a newly commercialized agglutination test that uses a monoclonal antibody specific for cryptococcal capsular polysaccharide (Pastorex Cryptococcus; Sanofi-Diagnostics Pasteur, Marnes-la-Coquette, France) and compared them with those of tests that use polyclonal immune sera (Cryptococcal Antigen Latex Agglutination System, Meridian Diagnostics, Inc., Cincinnati, Ohio; and Crypto-LA, International Biological Labs Inc., Cranbury, N.J.). The sensitivities and specificities of the tests were compared by using purified polysaccharides and yeast suspensions. Clinical specimens (131 serum samples, 41 cerebrospinal fluid samples, 34 urine samples, and 19 bronchoalveolar lavage samples) from 87 human immunodeficiency virus-positive subjects with (40 patients) and without (47 patients) culture-proven cryptococcosis were retrospectively tested during a blinded study. The effect of pronase treatment of samples was assessed for Pastorex Cryptococcus and the Cryptococcal Antigen Latex Agglutination System, and the antigen titers were compared. Our results show that (i) during the screening, concordance among the three tests was 97%; (ii) the use of pronase enhanced both the sensitivities and specificities of the Pastorex Cryptococcus test; (iii) titers agreed for 67% of the cerebrospinal fluid samples and 60% of the serum samples; and (iv) cryptococcosis was detected equally well with Pastorex Cryptococcus and with the other tests, whatever the infecting serotype (A, B, or D). The meaning of in vitro sensitivity and the relationship between titers and sensitivity are discussed. The results show that Pastorex Cryptococcus is a rapid and reliable test for the detection of cryptococcal antigen in body fluids and suggest that kits cannot be used interchangeably to monitor antigen titers in patients. PMID:1400951

  15. Determination of ABO blood grouping and Rhesus factor from tooth material

    PubMed Central

    Kumar, Pooja Vijay; Vanishree, M; Anila, K; Hunasgi, Santosh; Suryadevra, Sri Sujan; Kardalkar, Swetha

    2016-01-01

    Objective: The aim of the study was to determine blood groups and Rhesus factor from dentin and pulp using absorption-elution (AE) technique in different time periods at 0, 3, 6, 9 and 12 months, respectively. Materials and Methods: A total of 150 cases, 30 patients each at 0, 3, 6, 9 and 12 months were included in the study. The samples consisted of males and females with age ranging 13–60 years. Patient's blood group was checked and was considered as “control.” The dentin and pulp of extracted teeth were tested for the presence of ABO/Rh antigen, at respective time periods by AE technique. Statistical Analysis: Data were analyzed in proportion. For comparison, Chi-square test or Fisher's exact test was used for the small sample. Results: Blood group antigens of ABO and Rh factor were detected in dentin and pulp up to 12 months. For both ABO and Rh factor, dentin and pulp showed 100% sensitivity for the samples tested at 0 month and showed a gradual decrease in the sensitivity as time period increased. The sensitivity of pulp was better than dentin for both the blood grouping systems and ABO blood group antigens were better detected than Rh antigens. Conclusion: In dentin and pulp, the antigens of ABO and Rh factor were detected up to 12 months but showed a progressive decrease in the antigenicity as the time period increased. When compared the results obtained of dentin and pulp in ABO and Rh factor grouping showed similar results with no statistical significance. The sensitivity of ABO blood grouping was better than Rh factor blood grouping and showed a statistically significant result. PMID:27721625

  16. Two sensitizing oxidation products of p-phenylenediamine patch tested in patients allergic to p-phenylenediamine.

    PubMed

    Young, Ewa; Zimerson, Erik; Bruze, Magnus; Svedman, Cecilia

    2016-02-01

    The results from a previous study indicated the presence of several possible sensitizers formed during oxidation of the potent sensitizer p-phenylenediamine (PPD) to which PPD-sensitized patients might react, in various patterns. To extract and analyse a yellow spot from a thin-layer chromatogram with oxidized PPD, to which 6 of 14 (43%) PPD-positive patients had reacted in a previous study, in order to identify potential sensitizer(s) and to patch test this/these substance(s) in the 14 PPD-positive patients. The yellow spot was extracted from a thin-layer chromatogram of oxidized PPD, and two substances, suspected to be allergens, were identified by analysis with gas chromatography mass spectrometry (GCMS). The 14 PPD-positive patients, who had been previously tested with the thin-layer chromatogram of oxidized PPD, participated in the investigation, and were tested with dilutions of the two substances. GCMS analysis identified 4-nitroaniline and 4,4'-azodianiline in the yellow spot. Of the 14 PPD-positive test patients, 5 (36%) reacted to 4-nitroaniline and 9 (64%) reacted to 4,4'-azodianiline. The results show that 4-nitroaniline and 4,4'-azodianiline, formed during oxidation of PPD, are potent sensitizers. PPD-sensitized patients react to a high extent to concentrations equimolar to PPD of 4-nitroaniline and 4,4'-azodianiline. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. When does mass screening for open neural tube defects in low-risk pregnancies result in cost savings?

    PubMed Central

    Tosi, L L; Detsky, A S; Roye, D P; Morden, M L

    1987-01-01

    Using a decision analysis model, we estimated the savings that might be derived from a mass prenatal screening program aimed at detecting open neural tube defects (NTDs) in low-risk pregnancies. Our baseline analysis showed that screening v. no screening could be expected to save approximately $8 per pregnancy given a cost of $7.50 for the maternal serum alpha-feto-protein (MSAFP) test and a cost of $42,507 for hospital and rehabilitation services for the first 10 years of life for a child with spina bifida. When a more liberal estimate of the costs of caring for such a child was used, the savings with the screening program were more substantial. We performed extensive sensitivity analyses, which showed that the savings were somewhat sensitive to the cost of the MSAFP test and highly sensitive to the specificity (but not the sensitivity) of the test. A screening program for NTDs in low-risk pregnancies may result in substantial savings in direct health care costs if the screening protocol is followed rigorously and efficiently. PMID:2433011

  18. Increased risk of horse sensitization in southwestern Iranian horse riders.

    PubMed

    Moghtaderi, Mozhgan; Farjadian, Shirin; Hosseini, Zeynab; Raayat, Alireza

    2015-01-01

    The aim of this study has been to investigate the frequency of sensitization to horse allergens and clinical symptoms in horse riders. A total of 42 horse riders and 50 healthy individuals were examined by means of skin prick tests for a panel of horse and common animal allergens, and pulmonary function tests were done by spirometry. The rate of sensitization to horse allergens was 31% as proven by the skin prick test in horse riders whereas horse sensitization was not seen in the control group. Occupational allergy symptoms were reported by 19 horse riders. Two horse riders with no history of clinical symptoms showed positive skin reactions to horse allergens. To decrease the high risk of occupational sensitization among horse riders, workplace conditions should be improved to reduce the load of airborne horse allergens. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  19. Chamber Tests with Human Subjects XX. Hypersensitivity to H as Demonstrated by Patch Tests Before and After Chamber Exposure to H Vapor

    DTIC Science & Technology

    1946-05-15

    worn. In addition to erythema, edema and/or folliculitis were observed in only 2 of 230 men tested prior to exposure to H vapor. After exposure, 26% of...169 men manifested edema and/or folliculitis to patch tests. These men were arbitrarily considered "sensitized". This sensitized group also showed a...for edema or folliculitis , a value CONFIDENT-L.f, - 6 - C:7 Fx was calculated in which readings of 16 were assigned their erythema value of 8 and

  20. Oral rapid test: an alternative to traditional HIV screening in Chile

    PubMed Central

    Irarrazábal, Lisette Paola; Ferrer, Lilian; Cianelli, Rosina; Lara, Loreto; Reed, Reiley; Levy, Judith; Pérez, Carlos

    2016-01-01

    Objective To compare the sensitivity and specificity of an Oral Rapid Test (ORT) to that of the Enzyme-Linked Immunosorbent Assay (ELISA) for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants’ perceptions of the ORT compared to the ELISA. Methods A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. Results The ELISA reported 184 (37%) of the 497 participants as being “positive” for HIV antibodies; the ORT showed 181 (36.4%) as being “reactive” for HIV. The ORT showed a sensitivity of 98.4% (95.7%–99.9%, 95% Confidence Interval) and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001). Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. Conclusions The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. PMID:23939368

  1. Relationship of mechanical characteristics and microstructural features to the time-dependent edge notch sensitivity of inconel 718 sheet

    NASA Technical Reports Server (NTRS)

    Wilson, D. J.

    1971-01-01

    Time-dependent notch sensitivity of Inconel 718 sheet was observed at 900 F to 1200 F (482 - 649 C). It occurred when edge-notched specimens were loaded below the yield strength and smooth specimen tests showed that small amounts of creep consumed large rupture life fractions. The severity of the notch sensitivity was reduced by decreasing the solution temperature, increasing the time and/or temperature of aging and increasing the test temperature to 1400 F (760 C). Elimination of time-dependent notch sensitivity correlated with a change in dislocation motion mechanism from shearing to by-passing precipitate particles.

  2. A Dual Point-of-Care Test Shows Good Performance in Simultaneously Detecting Nontreponemal and Treponemal Antibodies in Patients With Syphilis: A Multisite Evaluation Study in China

    PubMed Central

    Yin, Yue-Ping; Chen, Xiang-Sheng; Wei, Wan-Hui; Gong, Kuang-Long; Cao, Wen-Ling; Yong, Gang; Feng, Liang; Huang, Shu-Jie; Wang, Dong-Mei; Han, Yan; Chen, Shao-Chun; Mabey, David; Peeling, Rosanna W.

    2013-01-01

    Background. Rapid point-of-care (POC) syphilis tests based on simultaneous detection of treponemal and nontreponemal antibodies (dual POC tests) offer the opportunity to increase coverage of syphilis screening and treatment. This study aimed to conduct a multisite performance evaluation of a dual POC syphilis test in China. Methods. Participants were recruited from patients at sexually transmitted infection clinics and high-risk groups in outreach settings in 6 sites in China. Three kinds of specimens (whole blood [WB], fingerprick blood [FB], and blood plasma [BP]) were used for evaluating sensitivity and specificity of the Dual Path Platform (DPP) Syphilis Screen and Confirm test using its treponemal and nontreponemal lines to compare Treponema pallidum particle agglutination (TPPA) assay and toluidine red unheated serum test (TRUST) as reference standards. Results. A total of 3134 specimens (WB 1323, FB 488, and BP 1323) from 1323 individuals were collected. The sensitivities as compared with TPPA were 96.7% for WB, 96.4% for FB, and 94.6% for BP, and the specificities were 99.3%, 99.1%, and 99.6%, respectively. The sensitivities as compared with TRUST were 87.2% for WB, 85.8% for FB, and 88.4% for BP, and the specificities were 94.4%, 96.1%, and 95.0%, respectively. For specimens with a TRUST titer of 1:4 or higher, the sensitivities were 100.0% for WB, 97.8% for FB, and 99.6% for BP. Conclusions. DPP test shows good sensitivity and specificity in detecting treponemal and nontreponemal antibodies in 3 kinds of specimens. It is hoped that this assay can be considered as an alternative in the diagnosis of syphilis, particularly in resource-limited areas. PMID:23132172

  3. [Penicillin allergy as a diagnostic problem. Overview and personal studies].

    PubMed

    Walker, T; Jung, E G; Bayerl, C

    2000-11-01

    Penicillin allergy is a common clinical problem. The distinction between penicillin and para-infectious exanthems is difficult. We investigated the reliability of the history, as well as the sensitivity and specificity of skin tests and specific IgE levels. 160 patients with a history of penicillin allergy were retrospectively evaluated in the outpatient department of a dermatological clinic. Nearly 50% were diagnosed as allergic to penicillin by detection of specific IgE or skin test. About 60% of the patients with immediate type reactions, and 72% with maculo-papular erythema showed positive reactions in skin tests. Significantly more patients were diagnosed as allergic to penicillin by intradermal testing than by prick testing (p < 0.05). The sensitivity of the specific IgE RAST was 17.9%; the specifity, 89.5%. For the prick test the sensitivity was 8.2%; the specificity 90.8%. For the intradermal test the sensitivity was 26%; the specifity 69.7%. We suggest a step by step procedure to detect penicillin allergy making the diagnostic results as valid as possible.

  4. Radiation prevulcanized natural rubber latex: Cytotoxicity and safety evaluation on animal

    NASA Astrophysics Data System (ADS)

    Keong, C. C.; Zin, W. M. Wan; Ibrahim, P.; Ibrahim, S.

    2010-05-01

    Radiation prevulcanized natural rubber latex (RVNRL) was claimed to be more user friendly than natural rubber latex prevulcanized by sulphur curing system. The absence of Type IV allergy inducing chemicals in RVNRL make it a suitable material for manufacturing of many kinds of latex products, especially those come into direct contact with users. This paper reveals and discusses the findings of cytotoxicity test and safety evaluation on animal for RVNRL. The test was done on RVNRL films prepared by coagulant dipping method and RVNRL dipped products produced by latex dipped product manufacturers. Cytotocixity test was carried out on mammalian cell culture American Type Culture Collection CCL 81, Vero. Results indicated that no cytotoxic effect from RVNRL films and products was found on the cell culture. Two animal studies, namely dermal sensitization study and primary skin irritation study, were done on gloves made from RVNRL. Albino white guinea pigs were used as test subjects in dermal sensitization study and results showed no sensitization induced by the application of test material in the guinea pigs. Primary skin irritation study was done on New Zealand white rabbits and results showed that the product tested was not corrosive and was not a primary irritant

  5. Gene expression profiles in auricle skin as a possible additional endpoint for determination of sensitizers: A multi-endpoint evaluation of the local lymph node assay.

    PubMed

    Tsuchiyama, Hiromi; Maeda, Akihisa; Nakajima, Mayumi; Kitsukawa, Mika; Takahashi, Kei; Miyoshi, Tomoya; Mutsuga, Mayu; Asaoka, Yoshiji; Miyamoto, Yohei; Oshida, Keiyu

    2017-10-05

    The murine local lymph node assay (LLNA) is widely used to test chemicals to induce skin sensitization. Exposure of mouse auricle skin to a sensitizer results in proliferation of local lymph node T cells, which has been measured by in vivo incorporation of H 3 -methyl thymidine or 5-bromo-2'-deoxyuridine (BrdU). The stimulation index (SI), the ratio of the mean proliferation in each treated group to that in the concurrent vehicle control group, is frequently used as a regulatory-authorized endpoint for LLNA. However, some non-sensitizing irritants, such as sodium dodecyl sulfate (SDS) or methyl salicylate (MS), have been reported as false-positives by this endpoint. In search of a potential endpoint to enhance the specificity of existing endpoints, we evaluated 3 contact sensitizers; (hexyl cinnamic aldehyde [HCA], oxazolone [OXA], and 2,4-dinitrochlorobenzene [DNCB]), 1 respiratory sensitizer (toluene 2,4-diisocyanate [TDI]), and 2 non-sensitizing irritants (MS and SDS) by several endpoints in LLNA. Each test substance was applied to both ears of female CBA/Ca mice daily for 3 consecutive days. The ears and auricle lymph node cells were analyzed on day 5 for endpoints including the SI value, lymph node cell count, cytokine release from lymph node cells, and histopathological changes and gene expression profiles in auricle skin. The SI values indicated that all the test substances induced significant proliferation of lymph node cells. The lymph node cell counts showed no significant changes by the non-sensitizers assessed. The inflammatory findings of histopathology were similar among the auricle skins treated by sensitizers and irritants. Gene expression profiles of cytokines IFN-γ, IL-4, and IL-17 in auricle skin were similar to the cytokine release profiles in draining lymph node cells. In addition, the gene expression of the chemokine CXCL1 and/or CXCL2 showed that it has the potential to discriminate sensitizers and non-sensitizing irritants. Our results suggest that multi-endpoint analysis in the LLNA leads to a better determination of the sensitizing potential of test substances. We also show that the gene expression of CXCL1 and/or CXCL2, which is involved in elicitation of contact hypersensitivity (CHS), can be a possible additional endpoint for discrimination of sensitizing compounds in LLNA. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Diagnostic value of the basophil activation test in evaluating Hymenoptera venom sensitization.

    PubMed

    Peternelj, Andreja; Silar, Mira; Bajrovic, Nissera; Adamic, Katja; Music, Ema; Kosnik, Mitja; Korosec, Peter

    2009-01-01

    Diagnosis of allergy to Hymenoptera venom is usually confirmed with skin testing and measurement of specific serum IgE antibody, tests which are sometimes inconclusive. In these cases, additional in vitro tests are necessary. The aim of this study was to show the applicability of the basophil activation test in detecting sensitization to Hymenoptera venom and to compare the test sensitivity and clinical positive-predictive value with skin prick tests and measurement of allergen-specific serum IgE. This prospective study was conducted between June 2004 and December 2007 and included a large group of 204 patients. All patients had a history of at least one systemic allergic reaction of Müller grades II-IV after a Hymenoptera sting. We compared results of the basophil activation test, specific serum IgE and skin prick tests with patients' clinical history and data on culprit insects. The overall clinical sensitivities of the basophil activation test, specific serum IgE and skin prick tests were 90%, 76% and 64%, respectively; the clinical positive-predictive values of the three tests were 79%, 73% and 78% for bee venom, 86%, 59% and 43% for wasp venom; and 84%, 77% and 22% for both venoms. Our results revealed a higher clinical sensitivity and comparable or better clinical positive-predictive value of basophil activation tests than skin prick tests and allergen-specific serum IgE in the detection of allergy to Hymenoptera venom.

  7. Special tinted contact lens on colour-defects.

    PubMed

    Mutilab, H A; Sharanjeet-Kaur; Keu, L K; Choo, P F

    2012-01-01

    The objective of this study was to determine the visual function of colour-deficient subjects when wearing special red tint contact lenses. A total of 17 subjects with congenital colour vision deficiency (14 deutans and 3 protans), voluntarily participated in this study. The average age for the subjects was 23.00 ± 4.06 years old. Visual functions tested were visual acuity (LogMAR), contrast sensitivity (FACT Chart) and stereopsis (TNO and Howard Dolman tests). Two types of special red tint lenses were used in this study; Type I (light red) and Type II (dark red). The protans and deutans showed no significant changes in visual acuity and contrast sensitivity when wearing either type of contact lens. Stereopsis testing using the Horward-Dolman test gave no significant changes but significant differences were seen using the TNO test. Stereopsis using the TNO test was significantly poorer with the red tinted contact lenses compared to without for both protons and deutans. Testing binocularly with Ishihara plates showed that 88% (n=15) of patients passed the test with Type I and Type II contact lenses. When D15 test was done, 3 patients (17.6%) were 'normal' when using the Type I contact lenses and 2 patients (11.8%) were 'normal' when using the Type II contact lenses. However, with FM100Hue test, most patients showed deutan responses. Total error scores (TES) were found to be higher with Type I and Type II contact lenses compared to without. The Type I and II special tinted contact lens used in this study did not cause a reduction of visual acuity and contrast sensitivity for the colour defects. Stereopsis was also not reduced with the Type I and Type II contact lenses for the colour defects except when tested with the TNO test. Colour vision defects became difficult to detect using the Ishihara plates but FM100Hue test did not show any improvement with the Type I and Type II contact lenses.

  8. The NOL Gap Test: Past, present, and future

    NASA Technical Reports Server (NTRS)

    Jacobs, S. J.; Price, D.

    1980-01-01

    A brief history of the development of the gap test is presented with emphasis on accumulated knowledge of how best to use it as a tool to assess relative shock sensitivity of explosives and propellants. Present information about the detonation process in build-up, steady state, and failure is used to show that failure diameter cannot give the desired shock sensitivity assessment. Suggestions are made for improving the test to an experiment. The use of spherical donors, water as attenuator, and camera instrumentation are briefly discussed.

  9. An evaporative and engine-cycle model for fuel octane sensitivity prediction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, D.P.; Taylor, A.B.

    The Motor Octane Number (MON) ranks fuels by their chemical resistance to knock. Evaporative cooling coupled with fuel chemistry determine Research Octane Number (RON) antiknock ratings. It is shown in this study that fuel Octane sensitivity (numerically RON minus MON) is liked to an important difference between the two test methods; the RON test allows each fuel`s evaporative cooling characteristics to affect gas temperature, while the MON test generally eliminates this effect by pre-evaporation. In order to establish RON test charge temperatures, a computer model of fuel evaporation was adapted to Octane Engine conditions, and simulations were compared with realmore » Octane Test Engine measurements including droplet and gas temperatures. A novel gas temperature probe yielded data that corresponded well with model predictions. Tests spanned single component fuels and blends of isomers, n-paraffins, aromatics and alcohols. Commercially available automotive and aviation gasolines were also tested. A good correlation was observed between the computer predictions and measured temperature data across the range of pure fuels and blends. A numerical method to estimate the effect of precombustion temperature differences on Octane sensitivity was developed and applied to analyze these data, and was found to predict the widely disparate sensitivities of the tested fuels with accuracy. Data are presented showing mixture temperature histories of various tested fuels, and consequent sensitivity predictions. It is concluded that a fuel`s thermal-evaporative behavior gives rise to fuel Octane sensitivity as measured by differences between the RON and MON tests. This is demonstrated by the success, over a wide range of fuels, of the sensitivity predictor method describes. Evaporative cooling, must therefore be regarded as an important parameter affecting the general road performance of automobiles.« less

  10. Basophil activation test discriminates between allergy and tolerance in peanut-sensitized children.

    PubMed

    Santos, Alexandra F; Douiri, Abdel; Bécares, Natalia; Wu, Shih-Ying; Stephens, Alick; Radulovic, Suzana; Chan, Susan M H; Fox, Adam T; Du Toit, George; Turcanu, Victor; Lack, Gideon

    2014-09-01

    Most of the peanut-sensitized children do not have clinical peanut allergy. In equivocal cases, oral food challenges (OFCs) are required. However, OFCs are laborious and not without risk; thus, a test that could accurately diagnose peanut allergy and reduce the need for OFCs is desirable. To assess the performance of basophil activation test (BAT) as a diagnostic marker for peanut allergy. Peanut-allergic (n = 43), peanut-sensitized but tolerant (n = 36) and non-peanut-sensitized nonallergic (n = 25) children underwent skin prick test (SPT) and specific IgE (sIgE) to peanut and its components. BAT was performed using flow cytometry, and its diagnostic performance was evaluated in relation to allergy versus tolerance to peanut and validated in an independent population (n = 65). BAT in peanut-allergic children showed a peanut dose-dependent upregulation of CD63 and CD203c while there was no significant response to peanut in peanut-sensitized but tolerant (P < .001) and non-peanut-sensitized nonallergic children (P < .001). BAT optimal diagnostic cutoffs showed 97% accuracy, 95% positive predictive value, and 98% negative predictive value. BAT allowed reducing the number of required OFCs by two-thirds. BAT proved particularly useful in cases in which specialists could not accurately diagnose peanut allergy with SPT and sIgE to peanut and to Arah2. Using a 2-step diagnostic approach in which BAT was performed only after equivocal SPT or Arah2-sIgE, BAT had a major effect (97% reduction) on the number of OFCs required. BAT proved to be superior to other diagnostic tests in discriminating between peanut allergy and tolerance, particularly in difficult cases, and reduced the need for OFCs. Copyright © 2014. Published by Elsevier Inc.

  11. Diagnostic power of laboratory tests for hereditary spherocytosis: a comparison study in 150 patients grouped according to molecular and clinical characteristics

    PubMed Central

    Bianchi, Paola; Fermo, Elisa; Vercellati, Cristina; Marcello, Anna P.; Porretti, Laura; Cortelezzi, Agostino; Barcellini, Wilma; Zanella, Alberto

    2012-01-01

    Background The laboratory diagnosis of hereditary spherocytosis commonly relies on NaCl-based or glycerol-based red cell osmotic fragility tests; more recently, an assay directly targeting the hereditary spherocytosis molecular defect (eosin-5′-maleimide-binding test) has been proposed. None of the available tests identifies all cases of hereditary spherocytosis. Design and Methods We compared the performances of the eosin-5′-maleimide-binding test, NaCl-osmotic fragility studies on fresh and incubated blood, the glycerol lysis test, the acidified glycerol lysis test, and the Pink test on a series of 150 patients with hereditary spherocytosis grouped according to clinical phenotype and the defective protein, with the final aim of finding the combination of tests associated with the highest diagnostic power, even in the mildest cases of hereditary spherocytosis. Results The eosin-5′-maleimide-binding test had a sensitivity of 93% and a specificity of 98% for detecting hereditary spherocytosis: the sensitivity was independent of the type and amount of molecular defect and of the clinical phenotype. The acidified glycerol lysis test and Pink test showed comparable sensitivity (95% and 91%). The sensitivity of NaCl osmotic fragility tests, commonly considered the gold standard for the diagnosis of hereditary spherocytosis, was 68% on fresh blood and 81% on incubated blood, and further decreased in compensated cases (53% and 64%, respectively). The combination of the eosin-5′-maleimide-binding test and acidified glycerol lysis test enabled all patients with hereditary spherocytosis to be identified. The eosin-5′-maleimide-binding test showed the greatest disease specificity. Conclusions Each type of test fails to diagnose some cases of hereditary spherocytosis. The association of an eosin-5′-maleimide-binding test and an acidified glycerol lysis test enabled identification of all patients with hereditary spherocytosis in this series and, therefore, represents a currently effective diagnostic strategy for hereditary spherocytosis including mild/compensated cases. PMID:22058213

  12. SFEMG in ocular myasthenia gravis diagnosis.

    PubMed

    Padua, L; Stalberg, E; LoMonaco, M; Evoli, A; Batocchi, A; Tonali, P

    2000-07-01

    In typical cases, the patient's history and clinical examination make it possible to diagnose ocular myasthenia gravis (OMG). But, in many cases a clear clinical picture is not present and OMG diagnosis is very difficult because gold diagnostic standard tests are not available. The diagnostic tests for OMG are usually unable to display a good sensitivity and specificity simultaneously. In this paper, we studied 86 cases submitted for suspected OMG. The patients were studied clinically and with various other tests used in OMG diagnosis (SFEMG, repetitive nerve stimulation, Ab anti AChR titration, tensilon test). SFEMG showed the highest sensitivity (100%) while Ab anti AChR showed the highest specificity (100%). To our knowledge this is the largest population of suspected OMG studied using most of the diagnostic parameters, reported in the literature.

  13. Sensitization to Food Additives in Patients with Allergy: A Study Based on Skin Test and Open Oral Challenge.

    PubMed

    Moghtaderi, Mozhgan; Hejrati, Zinatosadat; Dehghani, Zahra; Dehghani, Faranak; Kolahi, Niloofar

    2016-06-01

    There has been a great increase in the consumption of various food additives in recent years. The purpose of this study was to identify the incidence of sensitization to food additives by using skin prick test in patients with allergy and to determine the concordance rate between positive skin tests and oral challenge in hypersensitivity to additives. This cross-sectional study included 125 (female 71, male 54) patients aged 2-76 years with allergy and 100 healthy individuals. Skin tests were performed in both patient and control groups with 25 fresh food additives. Among patients with allergy, 22.4% showed positive skin test at least to one of the applied materials. Skin test was negative to all tested food additives in control group. Oral food challenge was done in 28 patients with positive skin test, in whom 9 patients showed reaction to culprit (Concordance rate=32.1%). The present study suggested that about one-third of allergic patients with positive reaction to food additives showed positive oral challenge; it may be considered the potential utility of skin test to identify the role of food additives in patients with allergy.

  14. Searching for the best real-time RT-PCRs to detect Zika virus infections: the importance of comparing several protocols.

    PubMed

    de Moraes, F M; Espósito, D L A; Klein, T M; da Fonseca, B A L

    2018-01-01

    Clinical manifestations of Zika, dengue, and chikungunya virus infections are very similar, making it difficult to reach a diagnosis based only on clinical grounds. In addition, there is an intense cross-reactivity between antibodies directed to Zika virus and other flaviviruses, and an accurate Zika diagnosis is best achieved by real-time RT-PCR. However, some real-time RT-PCR show better performance than others. To reach the best possible Zika diagnosis, the analytic sensitivity of some probe-based real-time RT-PCR amplifying Zika virus RNA was evaluated in spiked and clinical samples. We evaluated primers and probes to detect Zika virus, which had been published before, and tested sensitivity using serum spiked and patient samples by real-time RT-PCR. When tested against spiked samples, the previously described primers showed different sensitivity, with very similar results when samples from patients (serum and urine) were analyzed. Real-time RT-PCR designed to amplify Zika virus NS1 showed the best analytical sensitivity for all samples.

  15. Sensitivity and Specificity of Eustachian Tube Function Tests in Adults

    PubMed Central

    Doyle, William J.; Swarts, J. Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M.

    2013-01-01

    Objective Determine if Eustachian Tube (ET) function (ETF) tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and define the inter-relatedness of ETF test parameters. Methods ETF was evaluated using the Forced-Response, Inflation-Deflation, Valsalva and Sniffing tests in 15 control ears of adult subjects after unilateral myringotomy (Group I) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (Group II). Data were analyzed using logistic regression including each parameter independently and then a step-down Discriminant Analysis including all ETF test parameters to predict group assignment. Factor Analysis operating over all parameters was used to explore relatedness. Results The Discriminant Analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency and % positive pressure equilibrated) that together correctly assigned ears to Group II at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters, the first had negative loadings of the ETF structural parameters, the second had positive loadings of the muscle-assisted ET opening parameters and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. Discussion These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories. PMID:23868429

  16. Assessment of hypoallergenicity of ten skincare products.

    PubMed

    Brandt, Staci; Lio, Peter

    2014-03-01

    Sensitive skin is a common skin complaint frequently associated with skin diseases or adverse reactions to cosmetic products. Manufacturers have produced numerous products targeted for patients with sensitive skin and frequently label these products as being hypoallergenic. This term implies that the product may be less likely to cause an allergic reaction and be better suited for those with sensitive skin. However, there is no federal regulatory definition of this term and products may not have clinical support of their claim. Patch testing ingredients is frequently done to identify potential irritants; however, patch-testing product formulations may provide more realistic expectations about potential skin sensitivity and help support claims of hypoallergenicity. Ten skincare products were assessed for their sensitizing potential and hypoallergenicity in 14 repeat insult patch test clinical studies, involving over 2,000 subjects. In these studies, the products were deemed to be hypoallergenic if there was no evidence of sensitization or allergic reactions. The results from these trials demonstrated that all ten products were well tolerated, showed no sensitization or allergic reactions, and support claims of hypoallergenicity.

  17. Comparison of PanBio Dengue Duo Enzyme-Linked Immunosorbent Assay (ELISA) and MRL Dengue Fever Virus Immunoglobulin M Capture ELISA for Diagnosis of Dengue Virus Infections in Southeast Asia

    PubMed Central

    Cuzzubbo, Andrea J.; Vaughn, David W.; Nisalak, Ananda; Solomon, Tom; Kalayanarooj, Siripen; Aaskov, John; Dung, Nguyen Minh; Devine, Peter L.

    1999-01-01

    The performances of the MRL dengue fever virus immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) and the PanBio Dengue Duo IgM capture and IgG capture ELISA were compared. Eighty sera from patients with dengue virus infections, 24 sera from patients with Japanese encephalitis (JE), and 78 sera from patients with nonflavivirus infections, such as malaria, typhoid, leptospirosis, and scrub typhus, were used. The MRL test showed superior sensitivity for dengue virus infections (94 versus 89%), while the PanBio test showed superior specificity for JE (79 versus 25%) and other infections (100 versus 91%). The PanBio ELISA showed better overall performance, as assessed by the sum of sensitivity and specificity (F value). When dengue virus and nonflavivirus infections were compared, F values of 189 and 185 were obtained for the PanBio and MRL tests, respectively, while when dengue virus infections and JE were compared, F values of 168 and 119 were obtained. The results obtained with individual sera in the PanBio and MRL IgM ELISAs showed good correlation, but this analysis revealed that the cutoff value of the MRL test was set well below that of the PanBio test. Comparing the sensitivity and specificity of the tests at different cutoff values (receiver-operator analysis) revealed that the MRL and PanBio IgM ELISAs performed similarly in distinguishing dengue virus from nonflavivirus infections, although the PanBio IgM ELISA showed significantly better distinction between dengue virus infections and JE. The implications of these findings for the laboratory diagnosis of dengue are discussed. PMID:10473522

  18. Results with OECD recommended positive control sensitizers in the maximization, Buehler and local lymph node assays.

    PubMed

    Basketter, D A; Selbie, E; Scholes, E W; Lees, D; Kimber, I; Botham, P A

    1993-01-01

    The guinea pig maximization test and the Buehler occluded patch test are used widely to identify the sensitization potential of new chemicals. This information enables toxicologists and/or regulatory authorities to determine whether a chemical should be classified formally as a skin sensitizer. Both to improve and to harmonize these assessments internationally, the OECD has recommended recently that moderate rather than strong contact sensitizers are used as positive control substances. The purpose is to ensure an adequate level of sensitivity in sensitization assays performed at specific testing establishments. Results from two laboratories reported here show that the minimum acceptable standard laid down by the OECD can be achieved and indeed commonly exceeded by a substantial margin. Furthermore, results with these positive controls in a new method, the local lymph node assay, also appear to satisfy similar criteria, suggesting results from this assay, including negative data, should be acceptable for classification purposes. However, a review of the way in which results with new chemicals will be interpreted for regulatory purposes, in the context of positive control data, reveals that considerable inadequacies still exist. It is recommended that ultimately, sensitization data can only be interpreted meaningfully (i.e. to protect humans from sensitization hazards) by considering the potency of the contact allergen in the context of the sensitivity of the assay performed at the particular testing institution.

  19. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    PubMed

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  20. [Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].

    PubMed

    Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I

    2009-01-01

    The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.

  1. How Victim Sensitivity leads to Uncooperative Behavior via Expectancies of Injustice

    PubMed Central

    Maltese, Simona; Baumert, Anna; Schmitt, Manfred J.; MacLeod, Colin

    2016-01-01

    According to the Sensitivity-to-mean-intentions model, dispositional victim sensitivity involves a suspicious mindset that is activated by situational cues and guides subsequent information processing and behavior like a schema. Study 1 tested whether victim-sensitive persons are more prone to form expectancies of injustice in ambiguous situations and whether these expectancies mediate the relationship between victim sensitivity and cooperation behavior in a trust game. Results show an indirect effect of victim sensitivity on cooperation after unfair treatment (vs. control condition), mediated by expectancies of injustice. In Study 2 we directly manipulated the tendency to form expectancies of injustice in ambiguous situations to test for causality. Results confirmed that the readiness to expect unjust outcomes led to lower cooperation, compared to a control condition. These findings provide direct evidence that expectancy tendencies are implicated in elevated victim sensitivity and are of theoretical and practical relevance. PMID:26793163

  2. Lipopolysaccharide Specific Immunochromatography Based Lateral Flow Assay for Serogroup Specific Diagnosis of Leptospirosis in India

    PubMed Central

    Vanithamani, Shanmugam; Shanmughapriya, Santhanam; Narayanan, Ramasamy; Raja, Veerapandian; Kanagavel, Murugesan; Sivasankari, Karikalacholan; Natarajaseenivasan, Kalimuthusamy

    2015-01-01

    Background Leptospirosis is a re-emerging infectious disease that is under-recognized due to low-sensitivity and cumbersome serological tests. MAT is the gold standard test and it is the only serogroup specific test used till date. Rapid reliable alternative serogroup specific tests are needed for surveillance studies to identify locally circulating serogroups in the study area. Methods/Principal Findings In the present investigation the serological specificity of leptospiral lipopolysaccharides (LPS) was evaluated by enzyme linked immunosorbent assay (ELISA), dot blot assay and rapid immunochromatography based lateral flow assay (ICG-LFA). Sera samples from 120 MAT positive cases, 174 cases with febrile illness other than leptospirosis, and 121 seronegative healthy controls were evaluated for the diagnostic sensitivity and specificity of the developed assays. LPS was extracted from five locally predominant circulating serogroups including: Australis (27.5%), Autumnalis (11.7%), Ballum (25.8%), Grippotyphosa (12.5%), Pomona (10%) and were used as antigens in the diagnostics to detect IgM antibodies in patients’ sera. The sensitivity observed by IgM ELISA and dot blot assay using various leptospiral LPS was >90% for homologous sera. Except for Ballum LPS, no other LPS showed cross-reactivity to heterologous sera. An attempt was made to develop LPS based ICG-LFA for rapid and sensitive serogroup specific diagnostics of leptospirosis. The developed ICG-LFA showed sensitivity in the range between 93 and 100% for homologous sera. The Wilcoxon analysis showed LPS based ICG-LFA did not differ significantly from the gold standard MAT (P>0.05). Conclusion The application of single array of LPS for serogroup specific diagnosis is first of its kind. The developed assay could potentially be evaluated and employed for as MAT alternative. PMID:26340095

  3. The Ohio Contrast Cards: Visual Performance in a Pediatric Low-vision Site

    PubMed Central

    Hopkins, Gregory R.; Dougherty, Bradley E.; Brown, Angela M.

    2017-01-01

    SIGNIFICANCE This report describes the first clinical use of the Ohio Contrast Cards, a new test that measures the maximum spatial contrast sensitivity of low-vision patients who cannot recognize and identify optotypes and for whom the spatial frequency of maximum contrast sensitivity is unknown. PURPOSE To compare measurements of the Ohio Contrast Cards to measurements of three other vision tests and a vision-related quality-of-life questionnaire obtained on partially sighted students at Ohio State School for the Blind. METHODS The Ohio Contrast Cards show printed square-wave gratings at very low spatial frequency (0.15 cycle/degree). The patient looks to the left/right side of the card containing the grating. Twenty-five students (13 to 20 years old) provided four measures of visual performance: two grating card tests (the Ohio Contrast Cards and the Teller Acuity Cards) and two letter charts (the Pelli-Robson contrast chart and the Bailey-Lovie acuity chart). Spatial contrast sensitivity functions were modeled using constraints from the grating data. The Impact of Vision Impairment on Children questionnaire measured vision-related quality of life. RESULTS Ohio Contrast Card contrast sensitivity was always less than 0.19 log10 units below the maximum possible contrast sensitivity predicted by the model; average Pelli-Robson letter contrast sensitivity was near the model prediction, but 0.516 log10 units below the maximum. Letter acuity was 0.336 logMAR below the grating acuity results. The model estimated the best testing distance in meters for optimum Pelli-Robson contrast sensitivity from the Bailey-Lovie acuity as distance = 1.5 − logMAR for low-vision patients. Of the four vision tests, only Ohio Contrast Card contrast sensitivity was independently and statistically significantly correlated with students' quality of life. CONCLUSIONS The Ohio Contrast Cards combine a grating stimulus, a looking indicator behavior, and contrast sensitivity measurement. They show promise for the clinical objective of advising the patient and his/her caregivers about the success the patient is likely to enjoy in tasks of everyday life. PMID:28972542

  4. Detection of Delta9-tetrahydrocannabinol and amphetamine-type stimulants in oral fluid using the Rapid Stat point-of-collection drug-testing device.

    PubMed

    Röhrich, J; Zörntlein, S; Becker, J; Urban, R

    2010-04-01

    The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%. When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.

  5. Culture and drug sensitivity testing among patients with pulmonary tuberculosis in Mexico: national data for 2009-2013.

    PubMed

    Orejel, Ivonne; Castellanos, Martin; Marín, Diana; Mendoza, Alberto; Harries, Anthony D

    2016-01-01

    This study documented the number and results of mycobacterial culture and drug sensitivity testing (CDST) in Mexico from 2009-2013 and assessed whether states with a higher risk of multidrug-resistant tuberculosis (MDR-TB) performed more CDST and had more cultures showing MDR-TB. Data for this longitudinal, descriptive, operational research study came from the electronic records of 31 state public health laboratories in Mexico. The total number of CDSTs was 6 470, increasing from 2 143 in the first 2 years to 4 327 in the latter 3 years. There was a significant increase in the proportion of cultures showing sensitivity to all drugs, from 53.1% to 60.9% in 2011-2013 (P < 0.001) and a significant decrease in the proportion showing MDR-TB, from 28.2% in 2009 to 19.8% in 2013 (P < 0.001). Cases of extensively drug resistant tuberculosis were < 1% per year. In the 12 states with higher risk for MDR-TB, significantly more CDSTs (2 382 test) were done in 2011-2013 than in the other 19 states (1 945 tests). Also, for each year the proportion of cultures showing MDR-TB was significantly higher in high risk MDR-TB states than in lower risk ones (P < 0.001). During the 5-year study period, CDST was scaled up in Mexico, particularly in high-risk MDR-TB states where a higher proportion of cultures showed MDR-TB. Scale up and wider coverage of CDST should continue.

  6. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

    PubMed

    Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa

    2017-01-17

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.

  7. The influence of film-screen color sensitivity and type of measurement device on kVp measurements.

    PubMed

    Lam, R W; Price, S C

    1989-01-01

    Three methods for evaluating radiographic kVp were studied: the Wisconsin Test Cassette, the Noninvasive Evaluator of Radiation Outputs (NERO), and the Dynalyzer. The Dynalyzer kVp readings were the highest and were followed by NERO and cassette readings in descending order. By film type, the cassette readings ranged from Kodak OG (green sensitive), TMG (green sensitive), XK (blue sensitive), and XRP (blue sensitive) in descending order. The results show that there is significant variation between the methods.

  8. The Diagnostic Performance of Stool DNA Testing for Colorectal Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Zhai, Rong-Lin; Xu, Fei; Zhang, Pei; Zhang, Wan-Li; Wang, Hui; Wang, Ji-Liang; Cai, Kai-Lin; Long, Yue-Ping; Lu, Xiao-Ming; Tao, Kai-Xiong; Wang, Guo-Bin

    2016-02-01

    This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.

  9. Differential housing and novelty response: Protection and risk from locomotor sensitization.

    PubMed

    Garcia, Erik J; Haddon, Tara N; Saucier, Donald A; Cain, Mary E

    2017-03-01

    High novelty seeking increases the risk for drug experimentation and locomotor sensitization. Locomotor sensitization to psychostimulants is thought to reflect neurological adaptations that promote the transition to compulsive drug taking. Rats reared in enrichment (EC) show less locomotor sensitization when compared to rats reared in isolation (IC) or standard conditions (SC). The current research study was designed to test if novelty response contributed locomotor sensitization and more importantly, if the different housing environments could change the novelty response to protect against the development of locomotor sensitization in both adolescence and adulthood. Experiment 1: rats were tested for their response to novelty using the inescapable novelty test (IEN) and pseudorandomly assigned to enriched (EC), isolated (IC), or standard (SC) housing conditions for 30days. After housing, they were tested with IEN. Rats were then administered amphetamine (0.5mg/kg) or saline and locomotor activity was measured followed by a sensitization test 14days later. Experiment 2: rats were tested in the IEN test early adulthood and given five administrations of amphetamine (0.3mg/kg) or saline and then either stayed in or switched housing environments for 30days. Rats were then re-tested in the IEN test in late adulthood and administered five more injections of their respective treatments and tested for locomotor sensitization. Results indicate that IC and SC increased the response to novelty. EC housing decreased locomotor response to amphetamine and saline, and SC housing increased the locomotor response to amphetamine. Mediation results indicated that the late adult novelty response fully mediates the locomotor response to amphetamine and saline, while the early adulthood novelty response did not. Differential housing changes novelty and amphetamine locomotor response. Novelty response is altered into adulthood and provides evidence that enrichment can be used to reduce drug vulnerability. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study.

    PubMed

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan; Dirksen, Asger; Elberling, Jesper

    2011-06-01

    Multiple chemical sensitivity (MCS) is characterised by adverse effects due to exposure to low levels of chemical substances. The aetiology is unknown, but chemical related respiratory symptoms have been found associated with positive patch test. The purpose of this study was to investigate the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical sensitivity. Associations were controlled for the possible confounding effects of sex, age, asthma, eczema, atopic dermatitis, psychological and social factors, and smoking habits. In unadjusted analyses we found associations between allergic and non-allergic cutaneous reactions on patch testing and the two most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0.006). Our results suggest that individuals with self-reported chemical sensitivity show increased non-allergic cutaneous reactions based on day 2 readings of patch tests. Copyright © 2011 Elsevier GmbH. All rights reserved.

  11. Sensitivity of the activated partial thromboplastin time, the dilute Russell's viper venom time, and the kaolin clotting time for the detection of the lupus anticoagulant: a direct comparison using plasma dilutions.

    PubMed

    Martin, B A; Branch, D W; Rodgers, G M

    1996-01-01

    Increasing dilutions of lupus anticoagulant (LA) plasmas from twelve patients were used to directly compare the sensitivity of four tests for LA. The tests evaluated were the modified Bell and Alton activated partial thromboplastin time (APTT), an APTT using a commercially prepared partial thromboplastin (Platelin LS APTT), a modified dilute Russell's viper venom time (DRVVT), and a modified kaolin clotting time (KCT). LAs were detected in all twelve plasmas by each of three tests and eleven of twelve plasmas in a fourth test when undiluted patient plasma was used. Repeating the tests after diluting the LA plasmas with normal platelet-free plasma (PFP) showed that the KCT was the most sensitive test for LA, detecting eleven of twelve LAs at a dilution of 10% patient plasma and ten of twelve LAs at a dilution of 5% patient plasma. The modified Bell and Alton APTT and the modified DRVVT had similar sensitivities at a patient plasma concentration of 10%, detecting seven of twelve and eight of twelve LAs, respectively. The Platelin LS APTT detected only four of twelve LAs at a patient plasma concentration of 10%. Our results indicate that the modified KCT is a sensitive method for the detection of LAs. The modified Bell and Alton APTT and the DRVVT were less sensitive.

  12. The sensitizing capacity of multifunctional acrylates in the guinea pig.

    PubMed

    Björkner, B

    1984-10-01

    The multifunctional acrylates used in ultraviolet (UV) curable resins act as cross-linkers and "diluents". They are usually based on di(meth)acrylate esters of dialcohols or tri- and tetra-acrylate esters of polyalcohols. In UV-curable coatings, the most commonly used are pentaerythritol triacrylate (PETA), trimethylolpropane triacrylate (TMPTA) and 1,6-hexanediol diacrylate (HDDA). In other uses, such as dental composite resin materials, the dimethacrylic monomers based on n-ethylene glycol are the most useful. The sensitizing capacity of various multifunctional acrylates and their cross-reactivity pattern have been investigated with the guinea pig maximization test. The tests show that BUDA (1,4-butanediol diacrylate) and HDDA are moderate to strong sensitizers and that they probably cross-react with each other. The n-ethylene glycol diacrylates and methacrylates tested are weak or non-sensitizers. Tripropylene glycol diacrylate (TPGDA) is a moderate and neopentyl glycol diacrylate (NPGDA) a strong sensitizer, whereas neopentyl glycol dimethacrylate is a non-sensitizer. The commercial PETA is a mixture of pentaerythritol tri- and tetra-acrylate (PETA-3 and PETA-4). PETA-3 is a much stronger sensitizer than PETA-4. Simultaneous reactions were seen between PETA-3, PETA-4 and TMPTA. The oligotriacrylate OTA 480 is a moderate sensitizer, but no concomitant reactions were seen with PETA-3, PETA-4 or TMPTA. Of the multifunctional acrylates tested, the di- and triacrylic compounds should be regarded as potent sensitizers. The methacrylated multifunctional acrylic compounds are weak or non-sensitizers.

  13. Allergy to kiwi: is component-resolved diagnosis in routine clinical practice really impossible?

    PubMed

    Asero, R

    2012-04-01

    Kiwi allergy is frequent and can be the result of sensitization to a number of allergens showing different physicochemical characteristics. Component-resolved diagnosis of kiwi allergy is still unavailable in routine clinical practice. To investigate whether component resolved-diagnosis of kiwi allergy can be, at least in part, carried out by a proper combination of routinely available diagnostic tools. 63 adults with plant food allergy were studied 36 were kiwi-allergic while 27 were kiwi-tolerant and served as controls. Patients and controls underwent SPT with commercial peach and kiwi extracts, and with aprofilin-enriched date palm pollen extract (all by ALK-Abellò), and the measurement of IgE to birch, kiwi, and natural rubber latex. The in-vitro test showed poor sensitivity and specificity, as it scored positive in about 50% of patients and controls irrespective of clinical allergy to kiwi. The kiwi SPT showed overall poor sensitivity; however, it scored negative in all subjects with pollen food-allergy syndrome, was weakly positive in some lipid transfer protein-hypersensitive/kiwi tolerant subjects and in one latex-sensitized subject, and strongly positive in all subjects with primary kiwi sensitization. SPT with this commercial kiwi extract sensitively and specifically detects patients reacting to specific kiwi allergens. This can be useful to detect patients that are at risk of potentially severe reactions, particularly in case of co-sensitization to labile allergens, while we wait that the whole spectrum of kiwi allergens becomes available for routine in-vitro testing.

  14. Childhood Adversity and Pain Sensitization.

    PubMed

    You, Dokyoung Sophia; Meagher, Mary W

    Childhood adversity is a vulnerability factor for chronic pain. However, the underlying pain mechanisms influenced by childhood adversity remain unknown. The aim of the current study was to evaluate the impact of childhood adversity on dynamic pain sensitivity in young adults. After screening for childhood adverse events and health status, healthy individuals reporting low (below median; n = 75) or high levels of adversity (the top 5%; n = 51) were invited for pain testing. Both groups underwent heat pain threshold and temporal summation of second pain (TSSP) testing after reporting depressive symptoms. TSSP refers to a progressive increase in pain intensity with repetition of identical noxious stimuli and is attributed to central sensitization. Changes in pain ratings over time (slope) were computed for TSSP sensitization and decay of subsequent aftersensations. The high-adversity group showed greater TSSP sensitization (meanslope, 0.75; SDpositive slope, 1.78), and a trend toward a slower decay (meanslope, -11.9; SD, 3.4), whereas the low-adversity group showed minimal sensitization (meanslope, 0.07; SDnear-zero slope, 1.77), F(1,123) = 5.84, p = .017 and faster decay (meanslope, -13.1; SD, 3.4), F(1,123) = 3.79, p = .054. This group difference remained significant even after adjusting for adult depressive symptoms (p = .033). No group difference was found in heat pain threshold (p = .85). Lastly, the high-adversity group showed blunted cardiac and skin conductance responses. These findings suggest that enhancement of central sensitization may provide a mechanism underlying the pain hypersensitivity and chronicity linked to childhood adversity.

  15. Cost-effectiveness analysis of EGFR mutation testing in patients with non-small cell lung cancer (NSCLC) with gefitinib or carboplatin-paclitaxel.

    PubMed

    Arrieta, Oscar; Anaya, Pablo; Morales-Oyarvide, Vicente; Ramírez-Tirado, Laura Alejandra; Polanco, Ana C

    2016-09-01

    Assess the cost-effectiveness of an EGFR-mutation testing strategy for advanced NSCLC in first-line therapy with either gefitinib or carboplatin-paclitaxel in Mexican institutions. Cost-effectiveness analysis using a discrete event simulation (DES) model to simulate two therapeutic strategies in patients with advanced NSCLC. Strategy one included patients tested for EGFR-mutation and therapy given accordingly. Strategy two included chemotherapy for all patients without testing. All results are presented in 2014 US dollars. The analysis was made with data from the Mexican frequency of EGFR-mutation. A univariate sensitivity analysis was conducted on EGFR prevalence. Progression-free survival (PFS) transition probabilities were estimated on data from the IPASS and simulated with a Weibull distribution, run with parallel trials to calculate a probabilistic sensitivity analysis. PFS of patients in the testing strategy was 6.76 months (95 % CI 6.10-7.44) vs 5.85 months (95 % CI 5.43-6.29) in the non-testing group. The one-way sensitivity analysis showed that PFS has a direct relationship with EGFR-mutation prevalence, while the ICER and testing cost have an inverse relationship with EGFR-mutation prevalence. The probabilistic sensitivity analysis showed that all iterations had incremental costs and incremental PFS for strategy 1 in comparison with strategy 2. There is a direct relationship between the ICER and the cost of EGFR testing, with an inverse relationship with the prevalence of EGFR-mutation. When prevalence is >10 % ICER remains constant. This study could impact Mexican and Latin American health policies regarding mutation detection testing and treatment for advanced NSCLC.

  16. Individual modulation of pain sensitivity under stress.

    PubMed

    Reinhardt, Tatyana; Kleindienst, Nikolaus; Treede, Rolf-Detlef; Bohus, Martin; Schmahl, Christian

    2013-05-01

    Stress has a strong influence on pain sensitivity. However, the direction of this influence is unclear. Recent studies reported both decreased and increased pain sensitivities under stress, and one hypothesis is that interindividual differences account for these differences. The aim of our study was to investigate the effect of stress on individual pain sensitivity in a relatively large female sample. Eighty female participants were included. Pain thresholds and temporal summation of pain were tested before and after stress, which was induced by the Mannheim Multicomponent Stress Test. In an independent sample of 20 women, correlation coefficients between 0.45 and 0.89 indicated relatively high test-retest reliability for pain measurements. On average, there were significant differences between pain thresholds under non-stress and stress conditions, indicating an increased sensitivity to pain under stress. No significant differences between non-stress and stress conditions were found for temporal summation of pain. On an individual basis, both decreased and increased pain sensitivities under stress conditions based on Jacobson's criteria for reliable change were observed. Furthermore, we found significant negative associations between pain sensitivity under non-stress conditions and individual change of pain sensitivity under stress. Participants with relatively high pain sensitivity under non-stress conditions became less sensitive under stress and vice versa. These findings support the view that pain sensitivity under stress shows large interindividual variability, and point to a possible dichotomy of altered pain sensitivity under stress. Wiley Periodicals, Inc.

  17. Sensitivity of the Endogeic Tropical Earthworm Pontoscolex corethrurus to the Presence of Heavy Crude Oil.

    PubMed

    Del Carmen Cuevas-Díaz, María; Vázquez-Luna, Dinora; Martínez-Hernández, Sergio; Guzmán-López, Oswaldo; Ortíz-Ceballos, Angel I

    2017-08-01

    Contamination of soil with petroleum is common in oil-producing areas across the tropical regions of the world. There is limited knowledge on the sensitivity of endogeic tropical earthworms to the contamination of soil with total petroleum hydrocarbons (TPH) present in crude oil. Pontoscolex corethrurus is a dominant species in tropical agroecosystems around oil-processing facilities. The sensitivity of P. corethrurus to soil artificially contaminated with "Maya" Mexican heavy crude oil was investigated through avoidance and acute ecotoxicity tests, using the following measured concentrations: 0 (reference soil), 551, 969, 4845, 9991 and 14,869 mg/kg. The avoidance test showed that P. corethrurus displayed a significant avoidance behavior to heavy crude oil at a concentration of 9991 mg/kg or higher. In contrast, acute toxicity tests indicate that the median lethal concentration (LC 50 ) was 3067.32 mg/kg; however, growth (weight loss) was more sensitive than mortality. Our study revealed that P. corethrurus is sensitive to TPH, thus highlighting the importance of P. corethrurus for petroleum ecotoxicological tests.

  18. Biodegradable Polymers Induce CD54 on THP-1 Cells in Skin Sensitization Test.

    PubMed

    Jung, Yeon Suk; Kato, Reiko; Tsuchiya, Toshie

    2011-01-01

    Currently, nonanimal methods of skin sensitization testing for various chemicals, biodegradable polymers, and biomaterials are being developed in the hope of eliminating the use of animals. The human cell line activation test (h-CLAT) is a skin sensitization assessment that mimics the functions of dendritic cells (DCs). DCs are specialized antigen-presenting cells, and they interact with T cells and B cells to initiate immune responses. Phenotypic changes in DCs, such as the production of CD86 and CD54 and internalization of MHC class II molecules, have become focal points of the skin sensitization test. In this study, we used h-CLAT to assess the effects of biodegradable polymers. The results showed that several biodegradable polymers increased the expression of CD54, and the relative skin sensitizing abilities of biodegradable polymers were PLLG (75 : 25) < PLLC (40 : 60) < PLGA (50 : 50) < PCG (50 : 50). These results may contribute to the creation of new guidelines for the use of biodegradable polymers in scaffolds or allergenic hazards.

  19. The Collagen Gel Droplet-embedded Culture Drug Sensitivity Test in Relapsed Hepatoblastoma.

    PubMed

    Goto, Hiroaki; Kitagawa, Norihiko; Sekiguchi, Hironobu; Miyagi, Yohei; Keino, Dai; Sugiyama, Masanaka; Sarashina, Takeo; Miyagawa, Naoyuki; Yokosuka, Tomoko; Hamanoue, Satoshi; Iwasaki, Fuminori; Shiomi, Masae; Goto, Shoko; Tanaka, Yukichi

    2017-07-01

    There are few treatment options for patients with unresectable or refractory hepatoblastoma which has failed to respond to the standard treatment. The rarity of the disease and lack of experimental materials have hampered the development of new treatments. In this study, the collagen gel droplet-embedded culture drug sensitivity test was used to evaluate the effectiveness of the multikinase inhibitors sorafenib and sunitinib, and other drugs, in relapsed hepatoblastoma tumor tissues. Tumor samples from 6 patients with relapsed hepatoblastoma were tested for drug sensitivity by the collagen gel droplet-embedded culture drug sensitivity test; evaluable results were obtained from 5 of them. All samples were judged to be sensitive to sorafenib with a 50% growth inhibitory concentration (IC50) of 0.5 to 3.1 μg/mL. Sunitinib did not achieve IC50 in 2 of 3 samples within the tested concentration range based on clinically observed serum concentrations. In the drug combination assay using a hepatoblastoma cell line, sorafenib showed synergistic effects with SN-38, an active metabolite of irinotecan. Our results provide the basic science background warranting future clinical trials of a combination of sorafenib and irinotecan for relapsed or refractory hepatoblastoma.

  20. Monochromatic Measurements of the JPSS-1 VIIRS Polarization Sensitivity

    NASA Technical Reports Server (NTRS)

    McIntire, Jeff; Moyer, David; Brown, Steven W.; Lykke, Keith R.; Waluschka, Eugene; Oudrari, Hassan; Xiong, Xiaoxiong

    2016-01-01

    Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technologies Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about0.4 and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

  1. Differential Effects of Intermittent versus Continuous Haloperidol Treatment throughout Adolescence on Haloperidol Sensitization and Social Behavior in Adulthood

    PubMed Central

    Gao, Jun; Li, Ming

    2014-01-01

    Animal work on the behavioral effects of antipsychotic treatment suggests that different dosing regimens could affect drug sensitivity differently, with an intermittent treatment regimen tending to cause a sensitization effect, while a continuous treatment causing a tolerance. In this study, we explored how haloperidol (HAL) sensitization induced throughout adolescence and tested in adulthood was differentially impacted by these two dosing regimens in the conditioned avoidance response (CAR) test. We also examined how these two dosing regiments affected social interaction and social memory in adulthood. Male adolescent Sprague-Dawley rats were treated with HAL via either osmotic minipump (HAL-0.25 CONT; 0.25 mg/kg/day, n = 14) or daily injection (HAL-0.05 INT; 0.05 mg/kg/injection/day, sc, n = 14), or sterile water (n = 14) from postnatal days (PND) 44 to 71. HAL sensitization was assessed in a challenge test in which all rats were injected with HAL (0.025 and 0.05 mg/kg, sc) on PND 80 and PND 82. Two days later, half of the rats from each group (n = 7/group) were assayed in two 4-trial social interaction tests in which a subject rat was given four 5-min social encounters with a familiar or novel juvenile rat (PND 35–40) at 10 min intervals. Another half were tested in a quinpirole-induced hyperlocomotion assay to assess the potential HAL-induced change in D2-mediated function. Results show that only the intermittent dosing group under the HAL 0.05 mg/kg challenge showed a robust sensitization effect as rats in this group made significantly fewer avoidance responses than those in the vehicle and HAL-0.25 CONT groups. Adolescent HAL treatment did not affect social behavior and social memory, as rats from all 3 groups exhibited a similar level of social interaction and showed a similar level of sensitivity to the change of social stimuli. Similarly, adolescent HAL treatment also did not produce a long-lasting change in D2 function, as all 3 groups exhibited a similar level of increase in motor activity under quinpirole challenge. These findings suggest that HAL sensitization is a dosing-specific phenomenon. It is more likely to be seen under an intermittent dosing regimen than under a continuous dosing one. The findings that the intermittent HAL treatment did not impair social functioning and did not alter D2 function suggest a dissociation between drug-induced alterations in drug sensitivity and those in social function and neuroreceptors. PMID:24942467

  2. Usefulness of component resolved analysis of cat allergy in routine clinical practice.

    PubMed

    Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future studies may facilitate a better understanding of its use and subsequently may improve the clinical management of allergic patients.

  3. Sensitivity to Morphosyntactic Information in 3-Year-Old Children with Typical Language Development: A Feasibility Study

    ERIC Educational Resources Information Center

    Deevy, Patricia; Leonard, Laurence B.; Marchman, Virginia A.

    2017-01-01

    Purpose: This study tested the feasibility of a method designed to assess children's sensitivity to tense/agreement information in fronted auxiliaries during online comprehension of questions (e.g., "Are the nice little dogs running?"). We expected that a group of children who were proficient in auxiliary use would show this sensitivity,…

  4. Pooled analysis of the accuracy of five cervical cancer screening tests assessed in eleven studies in Africa and India.

    PubMed

    Arbyn, Marc; Sankaranarayanan, Rengaswamy; Muwonge, Richard; Keita, Namory; Dolo, Amadou; Mbalawa, Charles Gombe; Nouhou, Hassan; Sakande, Boblewende; Wesley, Ramani; Somanathan, Thara; Sharma, Anjali; Shastri, Surendra; Basu, Parthasarathy

    2008-07-01

    Cervical cancer is the main cancer among women in sub-Saharan Africa, India and other parts of the developing world. Evaluation of screening performance of effective, feasible and affordable early detection and management methods is a public health priority. Five screening methods, naked eye visual inspection of the cervix uteri after application of diluted acetic acid (VIA), or Lugol's iodine (VILI) or with a magnifying device (VIAM), the Pap smear and human papillomavirus testing with the high-risk probe of the Hybrid Capture-2 assay (HC2), were evaluated in 11 studies in India and Africa. More than 58,000 women, aged 25-64 years, were tested with 2-5 screening tests and outcome verification was done on all women independent of the screen test results. The outcome was presence or absence of cervical intraepithelial neoplasia (CIN) of different degrees or invasive cervical cancer. Verification was based on colposcopy and histological interpretation of colposcopy-directed biopsies. Negative colposcopy was accepted as a truly negative outcome. VIA showed a sensitivity of 79% (95% CI 73-85%) and 83% (95% CI 77-89%), and a specificity of 85% (95% CI 81-89%) and 84% (95% CI 80-88%) for the outcomes CIN2+ or CIN3+, respectively. VILI was on average 10% more sensitive and equally specific. VIAM showed similar results as VIA. The Pap smear showed lowest sensitivity, even at the lowest cutoff of atypical squamous cells of undetermined significance (57%; 95% CI 38-76%) for CIN2+ but the specificity was rather high (93%; 95% CI 89-97%). The HC2-assay showed a sensitivity for CIN2+ of 62% (95% CI 56-68%) and a specificity of 94% (95% CI 92-95%). Substantial interstudy variation was observed in the accuracy of the visual screening methods. Accuracy of visual methods and cytology increased over time, whereas performance of HC2 was constant. Results of visual tests and colposcopy were highly correlated. This study was the largest ever done that evaluates the cross-sectional accuracy of screening tests for cervical cancer precursors in developing countries. The merit of the study was that all screened subjects were submitted to confirmatory investigations avoiding to verification bias. A major finding was the consistently higher sensitivity but equal specificity of VILI compared with VIA. Nevertheless, some caution is warranted in the interpretation of observed accuracy measures, since a certain degree of gold standard misclassification cannot be excluded. Because of the correlation between visual screening tests and colposcopy and a certain degree of over-diagnosis of apparent CIN2+ by study pathologists, it is possible that both sensitivity and specificity of VIA and VILI were overestimated. Gold standard verification error could also explain the surprisingly low sensitivity of HC2, which contrasts with findings from other studies. (c) 2008 Wiley-Liss, Inc.

  5. Lepidoglyphus destructor acarus in the urban house environment.

    PubMed

    Juliá, J C; Martorell, A; Ventas, P; Cerdá, J C; Torró, I; Carreira, J; Guinot, E; Sanz, J; Alvarez, V

    1995-01-01

    To assess the presence of Lepidoglyphus destructor in the household environment of sensitized children living in an urban environment, samples of house dust were collected at the homes where two groups of patients were living, as well as in two bakeries in the city of Valencia, which were taken as a reference. Patients were divided into two groups. Group A included atopic children suffering from rhinitis and/or asthma, who were sensitized to L. destructor, as proven by prick test and specific IgE (CAP). Group B included children with the same features as those included in Group A, who were sensitized to Dermatophagoides pteronyssinus, with prick and CAP tests showing no significant sensitization to L. destructor. The samples of dust were analyzed, and the amounts of Der p I, Der f I, Der II and Lep d I per gram of dust were assessed through a solid-phase ELISA with monoclonal antibodies. In Group A, all patients but two showed a sensitization to D. pteronyssinus by prick test and serum IgE. At the homes of the patients from both groups, significant levels of Dermatophagoides were found. In Group A, only three houses showed levels of L. destructor which were comparable to those found in bakeries. Lep d I was not found in the houses of Group B patients. This means that a sensitization to L. destructor, as assessed with full extracts, is not always an indicator of its presence at the patient's house environment; it may rather refer to cross-reactivity to Dermatophagoides. Thus, availability of the main antigen Lep d I seems necessary to increase the specificity of the allergologic study.

  6. Validation of antibiotic residue tests for dairy goats.

    PubMed

    Zeng, S S; Hart, S; Escobar, E N; Tesfai, K

    1998-03-01

    The SNAP test, LacTek test (B-L and CEF), Charm Bacillus sterothermophilus var. calidolactis disk assay (BsDA), and Charm II Tablet Beta-lactam sequential test were validated using antibiotic-fortified and -incurred goat milk following the protocol for test kit validations of the U.S. Food and Drug Administration Center for Veterinary Medicine. SNAP, Charm BsDA, and Charm II Tablet Sequential tests were sensitive and reliable in detecting antibiotic residues in goat milk. All three assays showed greater than 90% sensitivity and specificity at tolerance and detection levels. However, caution should be taken in interpreting test results at detection levels. Because of the high sensitivity of these three tests, false-violative results could be obtained in goat milk containing antibiotic residues below the tolerance level. Goat milk testing positive by these tests must be confirmed using a more sophisticated methodology, such as high-performance liquid chromatography, before the milk is condemned. LacTek B-L test did not detect several antibiotics, including penicillin G, in goat milk at tolerance levels. However, LacTek CEF was excellent in detecting ceftiofur residue in goat milk.

  7. Relative sensitivity of Arctic species to physically and chemically dispersed oil determined from three hydrocarbon measures of aquatic toxicity.

    PubMed

    Bejarano, Adriana C; Gardiner, William W; Barron, Mace G; Word, Jack Q

    2017-09-15

    The risks to Arctic species from oil releases is a global concern, but their sensitivity to chemically dispersed oil has not been assessed using a curated and standardized dataset from spiked declining tests. Species sensitivity to dispersed oil was determined by their position within species sensitivity distributions (SSDs) using three measures of hydrocarbon toxicity: total petroleum hydrocarbons (TPH), polycyclic aromatic hydrocarbon (PAHs), and naphthalenes. Comparisons of SSDs with Arctic/sub-Arctic versus non-Arctic species, and across SSDs of compositionally similar oils, showed that Arctic and non-Arctic species have comparable sensitivities even with the variability introduced by combining data across studies and oils. Regardless of hydrocarbon measure, hazard concentrations across SSDs were protective of sensitive Arctic species. While the sensitivities of Arctic species to oil exposures resemble those of commonly tested species, PAH-based toxicity data are needed for a greater species diversity including sensitive Arctic species. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Allergenicity of orange juice and orange seeds: a clinical study.

    PubMed

    Zhu, S L; Ye, S T; Yu, Y

    1989-06-01

    Oranges are considered to be common allergenic fruits in China. They may induce severe food allergy in sensitive individuals. Allergic histories were analyzed in 26 orange-sensitive patients. Intradermal tests with extracts of orange juice and seeds were performed in 16 out of the 26 patients. P-K test was performed in one patient. The allergic history analysis suggested that clinical symptoms of some orange-allergic subjects were different from other fruit allergies but similar to nut and other oil plant seed allergies. The skin test and P-K test showed that the major allergenic components of orange reside in orange seeds instead of orange juice. Systemic reactions developed in 5 patients after intradermal tests with 1:20-200 (w/v) orange seed extracts. We considered that orange seed contains high potent allergens which may induce orange sensitivity due to careless chewing of orange seeds.

  9. Effects of symbiotic bacteria on chemical sensitivity of Daphnia magna.

    PubMed

    Manakul, Patcharaporn; Peerakietkhajorn, Saranya; Matsuura, Tomoaki; Kato, Yasuhiko; Watanabe, Hajime

    2017-07-01

    The crustacean zooplankton Daphnia magna has been widely used for chemical toxicity tests. Although abiotic factors have been well documented in ecotoxicological test protocols, biotic factors that may affect the sensitivity to chemical compounds remain limited. Recently, we identified symbiotic bacteria that are critical for the growth and reproduction of D. magna. The presence of symbiotic bacteria on Daphnia raised the question as to whether these bacteria have a positive or negative effect on toxicity tests. In order to evaluate the effects of symbiotic bacteria on toxicity tests, bacteria-free Daphnia were prepared, and their chemical sensitivities were compared with that of Daphnia with symbiotic bacteria based on an acute immobilization test. The Daphnia with symbiotic bacteria showed higher chemical resistance to nonylphenol, fenoxycarb, and pentachlorophenol than bacteria-free Daphnia. These results suggested potential roles of symbiotic bacteria in the chemical resistance of its host Daphnia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A one-dimensional interactive soil-atmosphere model for testing formulations of surface hydrology

    NASA Technical Reports Server (NTRS)

    Koster, Randal D.; Eagleson, Peter S.

    1990-01-01

    A model representing a soil-atmosphere column in a GCM is developed for off-line testing of GCM soil hydrology parameterizations. Repeating three representative GCM sensitivity experiments with this one-dimensional model demonstrates that, to first order, the model reproduces a GCM's sensitivity to imposed changes in parameterization and therefore captures the essential physics of the GCM. The experiments also show that by allowing feedback between the soil and atmosphere, the model improves on off-line tests that rely on prescribed precipitation, radiation, and other surface forcing.

  11. [How good are clinical investigative procedures for diagnosing meniscus lesions?].

    PubMed

    Jerosch, J; Riemer, S

    2004-06-01

    The purpose of this study was to evaluate different clinical meniscus tests. During 13 months we evaluated 64 patients with a suspected meniscus lesion in a prospective study. The age ranged from 16 to 76 years (average: 38.5 years). 66 % were male patients. Between the clinical examination and the arthroscopy there was no additional trauma to the knee. All patients were clinically examined in a standard manner by two independent orthopaedic surgeons. Clinical findings of the menisci were documented according to 12 well-described and commonly used meniscus tests. The arthroscopy was performed by a single surgeon who was not aware of the results of the clinical examination. This surgeon documented the intraarticular findings in a standardized operating report. A meniscus lesion/degeneration was documented when this was evident either by inspection or by palpation. The results showed either clinical meniscus tests with a high specificity and a low sensitivity or tests with a high sensitivity, but only a low specificity. We were not able to identify meniscus tests which showed both a high sensitivity and a high specificity. Even with access to MRI the clinical findings in knee joint with injured menisci still have a high diagnostic value. However, it seems to be necessary to combine different tests.

  12. Heightened Olfactory Sensitivity in Young Females with Recent-Onset Anorexia Nervosa and Recovered Individuals

    PubMed Central

    Bentz, Mette; Guldberg, Johanne; Vangkilde, Signe; Pedersen, Tine; Plessen, Kerstin Jessica; Jepsen, Jens Richardt Moellegaard

    2017-01-01

    Introduction Olfaction may be related to food restriction and weight loss. However, reports regarding olfactory function in individuals with anorexia nervosa (AN) have been inconclusive. Objective Characterize olfactory sensitivity and identification in female adolescents and young adults with first-episode AN and young females recovered from AN. Methods We used the Sniffin’ Sticks Odor Threshold Test and Odor Identification Test to assess 43 participants with first-episode AN, 27 recovered participants, and 39 control participants. Participants completed the Importance of Olfaction questionnaire, the Beck Youth Inventory and the Eating Disorder Inventory. We also conducted a psychiatric diagnostic interview and the Autism Diagnostic Observation Schedule with participants. Results Both clinical groups showed heightened olfactory sensitivity. After excluding participants with depression, participants with first-episode AN identified more odors than recovered participants. Conclusion Heightened olfactory sensitivity in AN may be independent of clinical status, whereas only individuals with current AN and without depression show more accurate odor identification. PMID:28060877

  13. The noninvasive mouse ear swelling assay. II. Testing the contact sensitizing potency of fragrances.

    PubMed

    Thorne, P S; Hawk, C; Kaliszewski, S D; Guiney, P D

    1991-11-01

    The noninvasive mouse ear swelling assay (MESA) for contact allergy testing was evaluated using fragrance components and complex fragrance mixtures. The test materials represented weak sensitizers and nonsensitizers. Two versions of the MESA were investigated. Both were noninvasive and utilized only topical abdominal dosing and ear challenge with single applications in BALB/cBy mice. The vit A MESA differed from the regular MESA only in that mice were maintained on a diet with 17-fold higher levels of vitamin A (vit A) acetate beginning 3 weeks prior to induction. Sensitization reactions were determined by measuring the mean increase in ear swelling over baseline at 24, 48 and 72 hr postexposure. Irritation dose-response curves facilitated choosing a high nonirritating challenge dose. Sensitization dose-response curves were developed for cinnamaldehyde (CINN) and a complex fragrance mixture, F-16. From these curves, the SD50 was determined. This value represents the dose which sensitized half the animals and serves to rank the potency of compounds for allergic contact dermatitis and to compare values among different assays. The SD50 for CINN was 21.6% while the SD50vit A for F-16 was 26.6%. The other fragrance, isoeugenol (ISOE), and fragrance mixtures, F-07 and F-22, were also found to be weak sensitizers in the MESA and vit A MESA. The results in the MESA for CINN and ISOE were in the range observed with guinea pig test protocols but showed that the MESA was more sensitive than human test protocols. Two of the fragrance mixtures tested in the MESA gave comparable results in the Buehler guinea pig assay. However, the third (F-22) was negative in the Buehler assay and the MESA, but positive in the vit A MESA. The results of this work with weak sensitizers and the companion study (Thorne et al., 1991) with potent sensitizers at low doses illustrate that the noninvasive MESA is as sensitive as many standard guinea pig assays. In addition, it is easier and much less expensive to perform. The vit A MESA has the sensitivity and predictive power needed to test compounds and mixtures for contact sensitizing potency.

  14. Colour preference and light sensitivity in trilobite larvae of mangrove horseshoe crab, Carcinoscopius rotundicauda (Latreille, 1802).

    PubMed

    Srijayat, T C; Pradeep, P J; Hassan, A; Chatterji, A; Shaharom, F; Jeffs, Andrew

    2014-03-01

    The trilobite larvae of C. rotundicauda were tested to determine their colour preference and light sensitivity until their first moulting (25 days post hatching) under laboratory conditions. Maximum congregation size of the trilobite larvae was found in the white zone respectively where (n = 12) followed by yellow (n = 8) and orange (n = 8), which showed the larval preference for lighter zones. Morisita's index calculation showed a clumped/aggregated distribution (yellow, blue, orange and white) and uniform/hyper dispersed distribution (green, red and black) for various colours tested. Trilobite larvae showed least preference for brighter regions while tested in the experiment [black; (n = 4) and red; (n = 5)]. Experiments done to determine the light sensitivity of trilobite larvae showed that the larvae had more preference towards ultraviolet lights. The maximum congregation size of 38.8 and 40.7% of the larvae was encountered under ultraviolet light, when the light sources were kept horizontal and vertical, respectively. Overall, results suggested that the trilobite larvae of C. rotundicauda, preferred light source of shorter wavelengths (UV light) and colours of lighter zone (white, yellow, orange), which might be due to their adaptation to their natural habitat for predator avoidance, prey selection and water quality.

  15. Basophil degranulation induced by oral poison ivy antigen.

    PubMed

    Shelley, W B; Resnik, S S

    1965-08-01

    Seven subjects shown by patch test to be sensitive to poison ivy oleoresin were challenged with graded oral doses of ivy extract. In each instance the circulating basophil leukocytes showed significant degranulation within one hour of challenge. This finding was interpreted as evidence of the presence of immediate-type circulating antibody to ivy antigen in these subjects. No drop in the absolute basophil count was noted, but with higher oral doses the degranulation persisted for several days. Thirteen control subjects showed no change in the basophil morphology or count, indicating that the resin at these levels was not toxic to this cell. All but one of the sensitive subjects showed objective patch test evidence of hyposensitization following the intensive three-week course of oral poison ivy antigen.

  16. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    PubMed

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  17. Single-tier testing with the C6 peptide ELISA kit compared with two-tier testing for Lyme disease.

    PubMed

    Wormser, Gary P; Schriefer, Martin; Aguero-Rosenfeld, Maria E; Levin, Andrew; Steere, Allen C; Nadelman, Robert B; Nowakowski, John; Marques, Adriana; Johnson, Barbara J B; Dumler, J Stephen

    2013-01-01

    For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7-71.1) and 35.2% (95% CI 30.6-40.1), respectively (P < 0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to 2-tier testing in sera from Lyme disease patients with early neurologic manifestations (88.6% versus 77.3%, P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (P < 0.05, 95% CI surrounding the 0.6 percentage point difference of 0.04 to 1.15). In conclusion, using a reference standard of 2-tier testing, the C6 ELISA as a single-step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with 2-tier testing in routine clinical practice. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. The effects of amphetamine exposure on outcome-selective Pavlovian-instrumental transfer in rats

    PubMed Central

    Shiflett, Michael W.

    2012-01-01

    Rationale Repeated exposure to psychostimulants alters behavioral responses to reward-related cues; however, the motivational underpinnings of this effect have not been fully characterized. Objectives The following study was designed to examine how amphetamine sensitization affects performance in rats on a series of Pavlovian and operant tasks that distinguish between general-incentive and outcome-selective forms of conditioned responses. Methods Adult male rats underwent Pavlovian and instrumental training for food pellet rewards. Following training, rats were sensitized to d-amphetamine (2 mg/kg for 7 days). Rats were subsequently tested on an outcome-selective Pavlovian-instrumental transfer (PIT) task, an outcome-reinstatement task, and an outcome devaluation task. Additionally, in a separate experiment PIT was assessed in amphetamine-sensitized and control rats using a Pavlovian backward-conditioned stimulus. Results Repeated amphetamine exposure sensitized locomotor activity to acute amphetamine challenge. Amphetamine altered responses to CS presentations by increasing conditioned approach. During tests of PIT amphetamine-treated rats showed no outcome-selectivity in their responding, responding to a CS whether or not it shared a common outcome with the instrumental response. No effect of amphetamine sensitization was observed on tests of outcome-selective reinstatement by outcome delivery, or action selection based on outcome value. Amphetamine-sensitized rats showed impaired outcome-selective PIT to a backward CS but were unaltered in conditioned approach. Conclusions Amphetamine sensitization prevents outcome-selective responding during PIT, which is dissociable from amphetamine’s effects on conditioned approach. These data suggest fundamental alterations in how stimuli motivate action in addiction. PMID:22562522

  19. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak P.; Gump, Jared C.

    2006-07-01

    Explosive formulations with reduced-sensitivity RDX showed reduced shock sensitivity using Naval Ordnance Laboratory (NOL) Large Scale Gap Test, compared with similar formulations using standard RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light on the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. I-RDX®, a form of reduced- sensitivity RDX was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transform IR (FTIR). The pressure dependence of the Raman mode frequencies of I-RDX® was determined and compared with that of standard RDX. The behavior of I-RDX® near the pressure at which standard RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph is presented.

  20. Study of positive and negative feedback sensitivity in psychosis using the Wisconsin Card Sorting Test.

    PubMed

    Farreny, Aida; Del Rey-Mejías, Ángel; Escartin, Gemma; Usall, Judith; Tous, Núria; Haro, Josep Maria; Ochoa, Susana

    2016-07-01

    Schizophrenia involves marked motivational and learning deficits that may reflect abnormalities in reward processing. The purpose of this study was to examine positive and negative feedback sensitivity in schizophrenia using computational modeling derived from the Wisconsin Card Sorting Test (WCST). We also aimed to explore feedback sensitivity in a sample with bipolar disorder. Eighty-three individuals with schizophrenia and 27 with bipolar disorder were included. Demographic, clinical and cognitive outcomes, together with the WCST, were considered in both samples. Computational modeling was performed using the R syntax to calculate 3 parameters based on trial-by-trial execution on the WCST: reward sensitivity (R), punishment sensitivity (P), and choice consistency (D). The associations between outcome variables and the parameters were investigated. Positive and negative sensitivity showed deficits, but P parameter was clearly diminished in schizophrenia. Cognitive variables, age, and symptoms were associated with R, P, and D parameters in schizophrenia. The sample with bipolar disorder would show cognitive deficits and feedback abnormalities to a lesser extent than individuals with schizophrenia. Negative feedback sensitivity demonstrated greater deficit in both samples. Idiosyncratic cognitive requirements in the WCST might introduce confusion when supposing model-free reinforcement learning. Negative symptoms of schizophrenia were related to lower feedback sensitivity and less goal-directed patterns of choice. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Octylisothiazolinone, an additional cause of allergic contact dermatitis caused by leather: case series and potential implications for the study of cross-reactivity with methylisothiazolinone.

    PubMed

    Aerts, Olivier; Meert, Hans; Romaen, Elien; Leysen, Julie; Matthieu, Lucretia; Apers, Sandra; Lambert, Julien; Goossens, An

    2016-11-01

    Octylisothiazolinone (OIT) is used as an antifungal agent by the leather industry. To show sensitization to OIT from leather, and to highlight the potential implications when cross-reactivity between OIT and methylisothiazolinone (MI) is studied. Two patients with allergic contact dermatitis caused by a leather belt and shoes, respectively, were patch tested with methylchloroisothiazolinone (MCI)/MI, MI, MCI, OIT, and benzisothiazolinone (BIT). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to detect isothiazolinone derivatives in leather goods. Additionally, files of OIT-sensitized patients, observed at the KU Leuven department during the period 1990-2015, were retrospectively analysed. Both patients had been primarily sensitized to OIT, but the diagnosis in one of them could be achieved only when a higher patch test concentration of OIT (1000 ppm pet.) was used. HPLC-UV confirmed the presence of OIT in their leather goods. Non-relevant sensitization to MI was noted in both cases. Four additional cases of OIT sensitization from leather could be retrieved from the KU Leuven database. Non-occupational sensitization to OIT from leather may occur. Patch test concentrations of >250 ppm pet. may be necessary for diagnosis, and to show cross-reactivity with MI. Safer use limits for OIT in the leather industry may be needed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    PubMed

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of <34, which accounted for 95.59% of the samples, was 100%. Discordant samples positive by RT-PCR but negative by EBOV-RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  3. The skin sensitization potential of four alkylalkanolamines.

    PubMed

    Leung, H W; Blaszcak, D L

    1998-04-01

    The skin sensitization potential of 4 alkylalkanolamines (N-methylethanolamine, N,N-dimethylethanolamine, N-methyldiethanolamine and N,N-diethylethanolamine), was evaluated in a guinea pig maximation procedure by the method of Magnusson and Kligman. While all 4 alkylalkanolamines tested were irritating to the guinea pig skin, only N-methylethanolamine showed potential to induce allergic contact dermatitis. None of the remaining 3 alkylalkanolamines exhibited clear skin responses suggestive of sensitization.

  4. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    PubMed Central

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  5. Evaluation of gamma interferon and antibody tuberculosis tests in alpacas.

    PubMed

    Rhodes, Shelley; Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-10-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a "test package," although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations.

  6. Cross-borehole slug test analysis in a fractured limestone aquifer

    NASA Astrophysics Data System (ADS)

    Audouin, Olivier; Bodin, Jacques

    2008-01-01

    SummaryThis work proposes new semi-analytical solutions for the interpretation of cross-borehole slug tests in fractured media. Our model is an extension of a previous work by Barker [Barker, J.A., 1988. A generalized radial flow model for hydraulic tests in fractured rock. Water Resources Research 24 (10), 1796-1804; Butler Jr., J.J., Zhan X., 2004. Hydraulic tests in highly permeable aquifers. Water Resources Research 40, W12402. doi:10.1029/2003/WR002998]. It includes inertial effects at both test and observation wells and a fractional flow dimension in the aquifer. The model has five fitting parameters: flow dimension n, hydraulic conductivity K, specific storage coefficient Ss, and effective lengths of test well Le and of observation well Leo. The results of a sensitivity analysis show that the most sensitive parameter is the flow dimension n. The model sensitivity to other parameters may be ranked as follows: K > Le ˜ Leo > Ss. The sensitivity to aquifer storage remains one or two orders of magnitude lower than that to other parameters. The model has been coupled to an automatic inversion algorithm for facilitating the interpretation of real field data. This inversion algorithm is based on a Gauss-Newton optimization procedure conditioned by re-scaled sensitivities. It has been used to interpret successfully cross-borehole slug test data from the Hydrogeological Experimental Site (HES) of Poitiers, France, consisting of fractured and karstic limestones. HES data provide flow dimension values ranging between 1.6 and 2.5, and hydraulic conductivity values ranging between 4.4 × 10 -5 and 7.7 × 10 -4 m s -1. These values are consistent with previous interpretations of single-well slug tests. The results of the sensitivity analysis are confirmed by calculations of relative errors on parameter estimates, which show that accuracy on n and K is below 20% and that on Ss is about one order of magnitude. The K-values interpreted from cross-borehole slug tests are one order of magnitude higher than those previously interpreted from interference pumping tests. These findings suggest that cross-borehole slug tests focus on preferential flowpath networks made by fractures and karstic channels, i.e. the head perturbation induced by a slug test propagates only through those flowpaths with the lowest hydraulic resistance. As a result, cross-borehole slug tests are expected to identify the hydrodynamic properties of karstic-channels and fracture flowpaths, and may be considered as complementary to pumping tests which more likely provide bulk properties of the whole fracture/karstic-channel/matrix system.

  7. Unsaturated fatty acids show clear elicitation responses in a modified local lymph node assay with an elicitation phase, and test positive in the direct peptide reactivity assay.

    PubMed

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Miyazaki, Hiroshi; Itagaki, Hiroshi

    2015-12-01

    The Organisation for Economic Co-operation and Development (OECD) Test Guidelines (TG) adopted the murine local lymph node assay (LLNA) and guinea pig maximization test (GPMT) as stand-alone skin sensitization test methods. However, unsaturated carbon-carbon double-bond and/or lipid acids afforded false-positive results more frequently in the LLNA compared to those in the GPMT and/or in human subjects. In the current study, oleic, linoleic, linolenic, undecylenic, fumaric, maleic, and succinic acid and squalene were tested in a modified LLNA with an elicitation phase (LLNA:DAE), and in a direct peptide reactivity assay (DPRA) to evaluate their skin-sensitizing potential. Oleic, linoleic, linolenic, undecylenic and maleic acid were positive in the LLNA:DAE, of which three, linoleic, linolenic, and maleic acid were positive in the DPRA. Furthermore, the results of the cross-sensitizing tests using four LLNA:DAE-positive chemicals were negative, indicating a chemical-specific elicitation response. In a previous report, the estimated concentration needed to produce a stimulation index of 3 (EC3) of linolenic acid, squalene, and maleic acid in the LLNA was < 10%. Therefore, these chemicals were classified as moderate skin sensitizers in the LLNA. However, the skin-sensitizing potential of all LLNA:DAE-positive chemicals was estimated as weak. These results suggested that oleic, linoleic, linolenic, undecylenic, and maleic acid had skin-sensitizing potential, and that the LLNA overestimated the skin-sensitizing potential compared to that estimated by the LLNA:DAE.

  8. Evaluation of Seegene Allplex Respiratory Panel 1 kit for the detection of influenza virus and human respiratory syncytial virus.

    PubMed

    Gimferrer, Laura; Andrés, Cristina; Rando, Ariadna; Piñana, Maria; Codina, Maria Gema; Martin, Maria Del Carmen; Fuentes, Francisco; Rubio, Susana; Alcubilla, Pilar; Pumarola, Tomàs; Antón, Andrés

    2018-05-25

    Influenza (FLUV) and human respiratory syncytial (HRSV) viruses are etiological agents of respiratory infections that cause a significant morbidity and mortality worldwide. A rapid and accurate diagnosis of these respiratory viruses is essential for an appropriate patient management. Molecular tests are the best detection option due to their high sensitivity and specificity. Seegene's Allplex™ Respiratory Panel 1 (Allplex RP1) is a real-time one-step RT-PCR assay for the simultaneous detection of FLUAV, FLUBV, HRSV-A and HRSV-B. In addition, it allows the determination of FLUAV subtype (H1, H3 and H1pdm09). This study aims to evaluate Allplex RP1 as a rapid molecular test for the detection of FLUAV, FLUBV, HRSV-A and HRSV-B viruses. The Allplex RP1 assay will be compared with other two commercial molecular assays, Prodesse ProFlu+ and ProFAST+ (Hologic, Madison, WI, USA), and GeneXpert Flu/RSV XC (Cepheid, USA). Allplex RP1, ProFlu+ and GeneXpert tests showed 95%, 91% and 96% of accuracy; and 94%, 88% and 95% of sensitivity, respectively. Moreover, Allplex RP1 showed a FLUAV subtype sensitivity of 91% and 88% for FLUAV-H1pdm09 and FLUAV-H3 respectively, and ProFAST+ assay showed sensitivities of 100% for both targets. The three assays showed a 100% of specificity and PPV, while the NPV were 84%, 73% and 86% for Allplex RP1, Prodesse and GeneXpert, respectively. In this study, Seegene's Allplex RP1 assay showed to be highly sensitive, specific, and suitable for detection of FLUV and HRSV, including FLUAV subtyping. In addition, it is also a hands-on-time saving assay due to the automated nucleic acid extraction and PCR setup. Copyright © 2018. Published by Elsevier B.V.

  9. Dermal safety assessment of Arm & Hammer laundry products formulated for sensitive skin.

    PubMed

    Frederick, Douglas M; Vorwerk, Linda; Gupta, Archana; Ghassemi, Annahita

    2017-09-01

    The prevalence of sensitive skin among the general population in industrialized countries is reported to be over 50%. Sensitive skin subjects often report significant reactions to contact with cosmetics, soaps and other consumer products. This paper describes the overall skin compatibility and mildness program for a newly developed, lightly fragranced, colorant free laundry product (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent), specially formulated for individuals with sensitive skin. The skin mildness of the product was compared to Arm & Hammer™ Free & Clear liquid laundry detergent with no fragrance or colorant, and an established history of safe use by sensitive skin consumers. The test material was a liquid laundry product with a light scent formulated for sensitive skin consumers (Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent). The product was compared to commercially marketed products for sensitive skin with a history of skin safety in the marketplace, including: a very similar product formulation (Arm & Hammer™ Free & Clear with no fragrance), and several selected competitors' products. Studies were conducted among individuals with self-assessed sensitive skin (based on a questionnaire) using standard protocols for the Human Repeat Insult Patch Test (HRIPT), 10-Day Cumulative Irritation, the Wrist Band Wear test, and the Safety In-Use testing. Responses in all protocols were evaluated by visual scoring of potential dermatologic reactions, and recording any sensory effects at the time of the examination. In addition, sensory effects collected from panelists' daily diaries were also evaluated. The HRIPT confirmed that neither the fragrance alone, nor the product formulation with fragrance, induced contact sensitization in sensitive skin subjects. The 10-Day cumulative irritation study conducted using sensitive skin subjects showed highly favorable skin compatibility, and the test product was comparable to the control product (Arm & Hammer Free & Clear) and other nonirritant controls. In the Wrist Band Wear test, exposure to laundered fabrics under exaggerated conditions gave similar results for the test and control products, with no objective signs of skin irritation, and no self-reported persistent adverse sensory effects. Very mild, transient and isolated sensory effects were noted in daily diaries by a small proportion of subjects, and were similar for the test and control products. The Safety In-Use tests evaluated 4-week exposure to product and laundered fabrics under realistic use conditions. There were no clinically objective signs of skin irritation, and reports of transitory, mild sensory effects were minimal and similar for the test and controls. A comprehensive skin safety program on a lightly scented sensitive skin laundry formulation (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent) conducted among panels of self-assessed sensitive skin subjects demonstrated that the presence of a light fragrance did not adversely impact skin compatibility in any of the testing protocols when the product was compared to a similar product with no fragrance. The lightly fragranced product demonstrated overall skin compatibility and mildness when tested in a self-assessed sensitive skin population, and compared favorably to currently marketed sensitive skin products.

  10. Increase in sensitization to oil of turpentine: recent data from a multicenter study on 45,005 patients from the German-Austrian Information Network of Departments of Dermatology (IVDK).

    PubMed

    Treudler, R; Richter, G; Geier, J; Schnuch, A; Orfanos, C E; Tebbe, B

    2000-02-01

    Contact allergy to oil of turpentine was reported to have become rare. However, the evaluation of standardized data of 45,005 patients tested 1992-1997 in 30 Dermatological Centers associated with the German-Austrian Information Network of Departments of Dermatology (IVDK) showed an increase in positive patch test reactions to turpentine from 0.5% during the years 1992-1995, up to 1.7% in 1996 and 3.1% in 1997. In particular, 17,347 patients tested in 1996-1997 were evaluated in detail by comparing 431 individuals with positive patch test reactions with the rest of the group found negative to turpentine. Using the so-called MOAHLFA index, the following characteristics were shown. Turpentine allergy (a) was found to be significantly less frequent in men and in patients with occupational dermatitis, (b) showed no difference in its association with atopic dermatitis, (c) patients with turpentine allergy had significantly less symptoms of the hands, more symptoms of the legs or in the face and (d) were significantly more often aged over 60 years. Also, patients sensitized to turpentine had increased rates of additional sensitizations. The definite reason for the increase in turpentine sensitization in the population tested here is not clear. Therefore, a detailed exposure analysis is necessary; the new increase in turpentine allergies may be due to popular topical remedies or household chemicals.

  11. Revisiting the role of language in spatial cognition: Categorical perception of spatial relations in English and Korean speakers.

    PubMed

    Holmes, Kevin J; Moty, Kelsey; Regier, Terry

    2017-12-01

    The spatial relation of support has been regarded as universally privileged in nonlinguistic cognition and immune to the influence of language. English, but not Korean, obligatorily distinguishes support from nonsupport via basic spatial terms. Despite this linguistic difference, previous research suggests that English and Korean speakers show comparable nonlinguistic sensitivity to the support/nonsupport distinction. Here, using a paradigm previously found to elicit cross-language differences in color discrimination, we provide evidence for a difference in sensitivity to support/nonsupport between native English speakers and native Korean speakers who were late English learners and tested in a context that privileged Korean. Whereas the former group showed categorical perception (CP) when discriminating spatial scenes capturing the support/nonsupport distinction, the latter did not. An additional group of native Korean speakers-relatively early English learners tested in an English-salient context-patterned with the native English speakers in showing CP for support/nonsupport. These findings suggest that obligatory marking of support/nonsupport in one's native language can affect nonlinguistic sensitivity to this distinction, contra earlier findings, but that such sensitivity may also depend on aspects of language background and the immediate linguistic context.

  12. Can Anxiety Tested in the Elevated Plus-maze Be Related to Nociception Sensitivity in Adult Male Rats?

    PubMed

    Pometlová, Marie; Yamamotová, Anna; Nohejlová, Kateryna; Šlamberová, Romana

    Methamphetamine (MA) is one of the most addictive psychostimulant drugs with a high potential for abuse. Our previous studies demonstrated that MA administered to pregnant rats increases pain sensitivity and anxiety in their adult offspring and makes them more sensitive to acute administration of the same drug in adulthood. Because individuals can differ considerably in terms of behaviour and physiology, such as rats that do not belong in some characteristics (e.g. anxiety) to average, can be described as low-responders or high-responders, are then more or less sensitive to pain. Therefore, prenatally MA-exposed adult male rats treated in adulthood with a single dose of MA (1 mg/ml/kg) or saline (1 ml/kg) were tested in the present study. We examined the effect of acute MA treatment on: (1) the anxiety in the Elevated plus-maze (EPM) test and memory in EPM re-test; (2) nociception sensitivity in the Plantar test; (3) the correlation between the anxiety, memory and the nociception. Our results demonstrate that: (1) MA has an anxiogenic effect on animals prenatally exposed to the same drug in the EPM; (2) all the differences induced by acute MA treatment disappeared within the time of 48 hours; (3) there was no effect of MA on nociception per se, but MA induced higher anxiety in individuals less sensitive to pain than in animals more sensitive to pain. In conclusion, the present study demonstrates unique data showing association between anxiety and nociceptive sensitivity of prenatally MA-exposed rats that is induced by acute drug administration.

  13. Comparison of cow-side diagnostic tests for subclinical mastitis of dairy cows in Musanze district, Rwanda.

    PubMed

    Iraguha, Blaise; Hamudikuwanda, Humphrey; Mushonga, Borden; Kandiwa, Erick; Mpatswenumugabo, Jean P

    2017-06-21

    Four subclinical mastitis diagnostic tests (the UdderCheck® test [a lactate dehydrogenasebased test], the California Mastitis Test [CMT], the Draminski® test [a conductivity-based test] and the PortaSCC® test [a portable somatic cell count-based test]) were compared in a study comprising crossbreed dairy cows (n = 30) during September and October 2015. Sensitivity and specificity of the CMT, Draminski® and UdderCheck® tests were compared with the PortaSCC® as reference. The CMT, Draminski® and UdderCheck® test results were compared with the results of the PortaSCC® test using kappa statistics. Duplicate quarter milk samples (n = 120) were concurrently subjected to the four tests. Sensitivity and specificity were 88.46% and 86.17% (CMT), 78.5% and 81.4% (Draminski®) and 64.00% and 78.95% (UdderCheck®). The CMT showed substantial agreement (k = 0.66), the Draminski® test showed moderate agreement (k = 0.48) and the UdderCheck® test showed fair agreement (k = 0.37) with the PortaSCC® test and positive likelihood ratios were 6.40, 4.15 and 3.04, respectively. The cow-level subclinical mastitis prevalence was 70%, 60%, 60% and 56.7% for PortaSCC®, CMT, Draminski® and UdderCheck® tests, respectively. At udder quarter level, subclinical mastitis prevalence was 20%, 21.67% and 20.83% for PortaSCC®, CMT and UdderCheck®, respectively. A correlation (P < 0.05) and moderate strength of association were found between the four tests used. The study showed that compared to the PortaSCC® test, the CMT was the most preferable option, followed by the Draminski® test, while the UdderCheck® test was the least preferable option for subclinical mastitis screening.

  14. Critical processes and parameters in the development of accident tolerant fuels drop-in capsule irradiation tests

    DOE PAGES

    Barrett, K. E.; Ellis, K. D.; Glass, C. R.; ...

    2015-12-01

    The goal of the Accident Tolerant Fuel (ATF) program is to develop the next generation of Light Water Reactor (LWR) fuels with improved performance, reliability, and safety characteristics during normal operations and accident conditions and with reduced waste generation. An irradiation test series has been defined to assess the performance of proposed ATF concepts under normal LWR operating conditions. The Phase I ATF irradiation test series is planned to be performed as a series of drop-in capsule tests to be irradiated in the Advanced Test Reactor (ATR) operated by the Idaho National Laboratory (INL). Design, analysis, and fabrication processes formore » ATR drop-in capsule experiment preparation are presented in this paper to demonstrate the importance of special design considerations, parameter sensitivity analysis, and precise fabrication and inspection techniques for figure innovative materials used in ATF experiment assemblies. A Taylor Series Method sensitivity analysis approach was used to identify the most critical variables in cladding and rodlet stress, temperature, and pressure calculations for design analyses. The results showed that internal rodlet pressure calculations are most sensitive to the fission gas release rate uncertainty while temperature calculations are most sensitive to cladding I.D. and O.D. dimensional uncertainty. The analysis showed that stress calculations are most sensitive to rodlet internal pressure uncertainties, however the results also indicated that the inside radius, outside radius, and internal pressure were all magnified as they propagate through the stress equation. This study demonstrates the importance for ATF concept development teams to provide the fabricators as much information as possible about the material properties and behavior observed in prototype testing, mock-up fabrication and assembly, and chemical and mechanical testing of the materials that may have been performed in the concept development phase. Special handling, machining, welding, and inspection of materials, if known, should also be communicated to the experiment fabrication and inspection team.« less

  15. Integration of an optical CMOS sensor with a microfluidic channel allows a sensitive readout for biological assays in point-of-care tests.

    PubMed

    Van Dorst, Bieke; Brivio, Monica; Van Der Sar, Elfried; Blom, Marko; Reuvekamp, Simon; Tanzi, Simone; Groenhuis, Roelf; Adojutelegan, Adewole; Lous, Erik-Jan; Frederix, Filip; Stuyver, Lieven J

    2016-04-15

    In this manuscript, a microfluidic detection module, which allows a sensitive readout of biological assays in point-of-care (POC) tests, is presented. The proposed detection module consists of a microfluidic flow cell with an integrated Complementary Metal-Oxide-Semiconductor (CMOS)-based single photon counting optical sensor. Due to the integrated sensor-based readout, the detection module could be implemented as the core technology in stand-alone POC tests, for use in mobile or rural settings. The performance of the detection module was demonstrated in three assays: a peptide, a protein and an antibody detection assay. The antibody detection assay with readout in the detection module proved to be 7-fold more sensitive that the traditional colorimetric plate-based ELISA. The protein and peptide assay showed a lower limit of detection (LLOD) of 200 fM and 460 fM respectively. Results demonstrate that the sensitivity of the immunoassays is comparable with lab-based immunoassays and at least equal or better than current mainstream POC devices. This sensitive readout holds the potential to develop POC tests, which are able to detect low concentrations of biomarkers. This will broaden the diagnostic capabilities at the clinician's office and at patient's home, where currently only the less sensitive lateral flow and dipstick POC tests are implemented. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. The tactile motion aftereffect suggests an intensive code for speed in neurons sensitive to both speed and direction of motion

    PubMed Central

    Birznieks, I.; Vickery, R. M.; Holcombe, A. O.; Seizova-Cajic, T.

    2016-01-01

    Neurophysiological studies in primates have found that direction-sensitive neurons in the primary somatosensory cortex (SI) generally increase their response rate with increasing speed of object motion across the skin and show little evidence of speed tuning. We employed psychophysics to determine whether human perception of motion direction could be explained by features of such neurons and whether evidence can be found for a speed-tuned process. After adaptation to motion across the skin, a subsequently presented dynamic test stimulus yields an impression of motion in the opposite direction. We measured the strength of this tactile motion aftereffect (tMAE) induced with different combinations of adapting and test speeds. Distal-to-proximal or proximal-to-distal adapting motion was applied to participants' index fingers using a tactile array, after which participants reported the perceived direction of a bidirectional test stimulus. An intensive code for speed, like that observed in SI neurons, predicts greater adaptation (and a stronger tMAE) the faster the adapting speed, regardless of the test speed. In contrast, speed tuning of direction-sensitive neurons predicts the greatest tMAE when the adapting and test stimuli have matching speeds. We found that the strength of the tMAE increased monotonically with adapting speed, regardless of the test speed, showing no evidence of speed tuning. Our data are consistent with neurophysiological findings that suggest an intensive code for speed along the motion processing pathways comprising neurons sensitive both to speed and direction of motion. PMID:26823511

  17. Remineralization of early enamel caries lesions using different bioactive elements containing toothpastes: An in vitro study.

    PubMed

    Wang, Yu; Mei, Li; Gong, Lin; Li, Jialing; He, Shaowei; Ji, Yan; Sun, Weibin

    2016-09-14

    Demineralization can be arrested or reversed when remineralization agents are applied to incipient carious or non-cavitated carious lesions. A large number of therapeutic agents including non-fluoridated products have been developed to promote enamel remineralization. This study aims to evaluate the efficacy of different bioactive elements containing toothpastes in remineralization of artificial enamel lesions. Artificial carious lesions were created on 40 human enamel slabs, and were randomly divided into four groups: (1) control group (no treatment), (2) casein phosphopeptide-amorphous calcium phosphate group (CPP-ACP, GC Tooth Mousse), (3) 8% arginine and calcium carbonate group (ACC, Colgate Sensitive Pro-Relief), (4) calcium sodium phosphosilicate group (CSP, NovaMin®). All samples were subjected to 15 days of pH-cycling. Subsequently, a one-hour acid resistance test was carried out. Surface hardness of the samples was assessed using the Knoop hardness test, and surface morphology and roughness were assessed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Data were analyzed using one-way ANOVA, Tukey's test and paired t test. The three tested toothpastes exhibited a significantly higher remineralization efficacy compared with the control group (P< 0.05 for all). After pH-cycling, the specimens treated with Colgate Sensitive Pro-Relief and NovaMin® showed a significant higher surface hardness (P< 0.001 and P= 0.03, respectively) and lower surface roughness (P< 0.05 for both) compared those treated with GC Tooth Mousse. While after the acid resistance test, all groups showed a significant loss of surface hardness (P< 0.001 for all) and significant increase of surface roughness (P< 0.05). The specimens treated with Colgate Sensitive Pro-Relief and NovaMin® still showed a significant higher surface hardness and lower surface roughness in comparison with those treated with GC Tooth Mousse (P< 0.05 for all). No significant difference was found in surface hardness and roughness between Colgate Sensitive Pro-Relief and NovaMin® during the pH-cycling test and acid resistance test (P= 0.45 and P= 0.83, respectively). Colgate Sensitive Pro-Relief and NovaMin® present an advantage in enhancing remineralization and inhibiting demineralization for early enamel carious lesions in comparison with GC Tooth Mousse.

  18. [Performance of cognitive brief test in elderly patients with dementia in advanced stage living in an urban community of Lima, Peru].

    PubMed

    Custodio, Nilton; Alva-Diaz, Carlos; Becerra-Becerra, Yahaira; Montesinos, Rosa; Lira, David; Herrera-Pérez, Eder; Castro-Suárez, Sheila; Cuenca-Alfaro, José; Valeriano-Lorenzo, Elizabeth

    2016-01-01

    Evaluate the performance of clock drawing test- Manos versión (PDR-M) and Mini Mental State Examination -Peruvian version (MMSE) to detect dementia in a sample based on urban community of Lima, Peru. This study is a secondary analysis database, observational, analytical and cross-sectional, the gold standard was the clinical and the neuropsychological evaluations together. Performance testing individually and in combination were evaluated.. Data were obtained from prevalence study conducted in 2008 in Cercado de Lima. MMSE performance for evaluation of patients with dementia of any kind showed sensitivity of 64,1%, specificity of 84,1%, PPV of 24.4%, NPV of 96.7%, PLR of 4,03 and NLR of 0,43. PDR-M showed sensitivity of 89,3%, specificity of 98,1%, PPV of 79.3%, NPV of 99.1%, PLR of 47,79 and NLR of 0,11. When both tests were applied, and at least one of them was positive, they showed sensitivity 98.1%, specificity 84.1%, PPV of 33.1%, NPV of 99.8%, PLR of 6,17 and NLR of 0,02. When performing separate analysis of Alzheimer-type dementia and non- Alzheimer dementia, the values of the parameters do not differ substantially from those obtained for dementia of any kind. The combination of MMSE and PDR-M show good discriminative ability to detect moderate and severe dementia in population living in urban community in Lima.

  19. Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

    PubMed Central

    Al-Saleh, Ayman; Alazzoni, Ashraf; Al Shalash, Saleh; Ye, Chenglin; Mbuagbaw, Lawrence; Thabane, Lehana; Jolly, Sanjit S.

    2014-01-01

    Background High-sensitivity cardiac troponin assays have been adopted by many clinical centres worldwide; however, clinicians are uncertain how to interpret the results. We sought to assess the utility of these assays in diagnosing acute myocardial infarction (MI). Methods We carried out a systematic review and meta-analysis of studies comparing high-sensitivity with conventional assays of cardiac troponin levels among adults with suspected acute MI in the emergency department. We searched MEDLINE, EMBASE and Cochrane databases up to April 2013 and used bivariable random-effects modelling to obtain summary parameters for diagnostic accuracy. Results We identified 9 studies that assessed the use of high-sensitivity troponin T assays (n = 9186 patients). The summary sensitivity of these tests in diagnosing acute MI at presentation to the emergency department was estimated to be 0.94 (95% confidence interval [CI] 0.89–0.97); for conventional tests, it was 0.72 (95% CI 0.63–0.79). The summary specificity was 0.73 (95% CI 0.64–0.81) for the high-sensitivity assay compared with 0.95 (95% CI 0.93–0.97) for the conventional assay. The differences in estimates of the summary sensitivity and specificity between the high-sensitivity and conventional assays were statistically significant (p < 0.01). The area under the curve was similar for both tests carried out 3–6 hours after presentation. Three studies assessed the use of high-sensitivity troponin I assays and showed similar results. Interpretation Used at presentation to the emergency department, the high-sensitivity cardiac troponin assay has improved sensitivity, but reduced specificity, compared with the conventional troponin assay. With repeated measurements over 6 hours, the area under the curve is similar for both tests, indicating that the major advantage of the high-sensitivity test is early diagnosis. PMID:25295240

  20. Measuring hearing in the harbor seal (Phoca vitulina): Comparison of behavioral and auditory brainstem response techniques

    NASA Astrophysics Data System (ADS)

    Wolski, Lawrence F.; Anderson, Rindy C.; Bowles, Ann E.; Yochem, Pamela K.

    2003-01-01

    Auditory brainstem response (ABR) and standard behavioral methods were compared by measuring in-air audiograms for an adult female harbor seal (Phoca vitulina). Behavioral audiograms were obtained using two techniques: the method of constant stimuli and the staircase method. Sensitivity was tested from 0.250 to 30 kHz. The seal showed good sensitivity from 6 to 12 kHz [best sensitivity 8.1 dB (re 20 μPa2.s) RMS at 8 kHz]. The staircase method yielded thresholds that were lower by 10 dB on average than the method of constant stimuli. ABRs were recorded at 2, 4, 8, 16, and 22 kHz and showed a similar best range (8-16 kHz). ABR thresholds averaged 5.7 dB higher than behavioral thresholds at 2, 4, and 8 kHz. ABRs were at least 7 dB lower at 16 kHz, and approximately 3 dB higher at 22 kHz. The better sensitivity of ABRs at higher frequencies could have reflected differences in the seal's behavior during ABR testing and/or bandwidth characteristics of test stimuli. These results agree with comparisons of ABR and behavioral methods performed in other recent studies and indicate that ABR methods represent a good alternative for estimating hearing range and sensitivity in pinnipeds, particularly when time is a critical factor and animals are untrained.

  1. Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome.

    PubMed

    Wang, Zhixue; Zou, Yuanyuan; Li, Wenying; Wang, Xueyan; Zhang, Min; Wang, Wenying

    2015-11-01

    This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests.Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal-Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance.The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P < 0.01). Besides, OCT manifestations were associated with CS at each spacial frequency including 1.5, 3, 6, 12, and 18 frequency (P < 0.01). And patients with abnormal manifestations of OCT showed lower CS at each spacial frequency than those without abnormal OCT manifestations. What's more the OCT manifestation 1 showed the greatest impact on CS at each spacial frequency.The results showed that abnormal OCT manifestations were correlated with CS in PIHS. OCT and CS tests might be valuable methods in observing fundus changes for PIHS patients.

  2. Hair dye dermatitis and p-phenylenediamine contact sensitivity: A preliminary report

    PubMed Central

    Gupta, Mrinal; Mahajan, Vikram K.; Mehta, Karaninder S.; Chauhan, Pushpinder S.

    2015-01-01

    Background: The contact allergic reactions from p-phenylenediamine (PPD) in hair dyes vary from mild contact dermatitis to severe life- threatening events (angioedema, bronchospasm, asthma, renal impairment). Objectives: To study the clinical patterns and PPD contact sensitivity in patients with hair-dye dermatitis. Materials and Methods: Eighty (M:F 47:33) consecutive patients aged between 18 and 74 years suspected to have contact allergy from hair dye were studied by patch testing with Indian Standard Series including p-phenylenediamine (PPD, 1.0% pet). Results: 54 Fifty-four (M:F 21:33) patients showed positive patch tests from PPD. Eight of these patients also showed positive patch test reaction from fragrance mix, thiuram mix, paraben mix, or colophony. Fifty-seven (71%) patients affected were aged older than 40 years. The duration of dermatitis varied from < 1 month to > 1 year with exacerbation following hair coloring. Forty-nine patients had dermatitis of scalp and/or scalp margins and 23 patients had face and neck dermatitis. Periorbital dermatitis, chronic actinic dermatitis, and erythema multiforme-like lesions were seen in 4, 2, and 1 patients, respectively. Conclusions: Hair dyes and PPD constitute a significant cause of contact dermatitis. There is an urgent need for creating consumer awareness regarding hair-dyes contact sensitivity and the significance of performing sensitivity testing prior to actual use. PMID:26225326

  3. The sensitivity of laboratory tests assessing driving related skills to dose-related impairment of alcohol: A literature review.

    PubMed

    Jongen, S; Vuurman, E F P M; Ramaekers, J G; Vermeeren, A

    2016-04-01

    Laboratory tests assessing driving related skills can be useful as initial screening tools to assess potential drug induced impairment as part of a standardized behavioural assessment. Unfortunately, consensus about which laboratory tests should be included to reliably assess drug induced impairment has not yet been reached. The aim of the present review was to evaluate the sensitivity of laboratory tests to the dose dependent effects of alcohol, as a benchmark, on performance parameters. In total, 179 experimental studies were included. Results show that a cued go/no-go task and a divided attention test with primary tracking and secondary visual search were consistently sensitive to the impairing effects at medium and high blood alcohol concentrations. Driving performance assessed in a simulator was less sensitive to the effects of alcohol as compared to naturalistic, on-the-road driving. In conclusion, replicating results of several potentially useful tests and their predictive validity of actual driving impairment should deserve further research. In addition, driving simulators should be validated and compared head to head to naturalistic driving in order to increase construct validity. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Skin testing of guinea pigs and footpad testing of mice with a new antigen for detecting delayed hypersensitivity to Cryptococcus neoformans.

    PubMed

    Murphy, J W; Gregory, J A; Larsh, H W

    1974-02-01

    This study was undertaken to evaluate the potential of a cryptococcal culture filtrate antigen, cryptococcin C184, for detecting delayed hypersensitivity in Cryptococcus neoformans-injected animals. The antigen was tested on guinea pigs which had received saline or C. neoformans and on animals sensitized to Histoplasma capsulatum, Blastomyces dermatitidis, Candida albicans, or Sporothrix schenckii. A delayed-type hypersensitivity response was elicited by cryptococcin C184 in C. neoformans-injected guinea pigs, whereas no indurations or erythemas were seen at 48 h after skin testing of saline controls or heterologously sensitized guinea pigs. Besides being specific for Cryptococcus, the antigen showed a high degree of sensitivity and was reproducible. Footpad tests were conducted with the antigen on mice which had previously received either 10(5) viable C. neoformans cells or saline. Delayed hypersensitivity was indicated in the C. neoformans-injected mice by the increase in thickness of antigen-injected footpads when compared with the saline-injected footpads. In control mice, antigen- and saline-injected footpads were comparable in thickness 24 h after injection. Mice sensitized to B. dermatitidis were footpad tested with C184, and no cross-reactivity was demonstrated.

  5. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    PubMed

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  6. Is the European standard series suitable for patch testing in Riyadh, Saudi Arabia?

    PubMed

    el-Rab, M O; al-Sheikh, O A

    1995-11-01

    Due to the lack of a regional patch test series in our geographical area, the suitability of the European standard series was evaluated by patch testing dermatitis patients in Riyadh, Saudi Arabia. Of 240 consecutive patients with various forms of dermatitis, 136 (57%) showed 1 or more positive patch tests, women, 74 (54%), slightly outnumbering men, 62 (46%). Positive reactions were found to 21 of the 22 items in the test series. Sensitization was most common to nickel sulfate (51 = 37.5%), potassium dichromate (48 = 35%) and cobalt chloride (43 = 32%) The frequency of sensitization to nickel was higher in women (41 = 30%) while that to dichromate was higher in men (39 = 29%). Less reactions were found to fragrance mix (21 = 15%), formaldehyde (15 = 11%) and neomycin sulfate (15 = 11%). Sensitization to other allergens ranged between 10 and 1%. Less than 1% of patients (0.7%) reacted to benzocaine and none to primin. The frequency of occurrence of multiple sensitivities is also presented. We conclude that the European standard series is suitable for patch testing dermatitis patients in our region, with the exception of benzocaine and primin. The addition of 3 allergens that could be of local relevance is discussed.

  7. Evaluation of anti-microbial activity of spore powder of Ganoderma lucidum on clinical isolates of Prevotella intermedia: A pilot study.

    PubMed

    Nayak, Ranganath N; Dixitraj, P T; Nayak, Aarati; Bhat, Kishore

    2015-09-01

    This study aimed at evaluating the anti-microbial activity of spore powder of Ganoderma lucidum on Prevotella intermedia isolated from subgingival plaque from chronic periodontitis patients. Written informed consent was obtained from each subject enrolled in the study. The Institutional Ethics Committee granted the ethical clearance for the study. This study included 20 patients diagnosed with chronic periodontitis. Pooled subgingival plaque samples were collected using sterile curettes from the deepest sites of periodontal pockets. The collected samples were then transported in 1 mL of reduced transport fluid. The organisms were cultured and confirmed. These organisms were then used for minimum inhibitory concentration (MIC) procedure. Mean of the MIC value obtained was calculated. Thirteen out of the 20 clinical samples were tested that showed sensitivity at various concentrations. Five samples showed sensitivity at all concentrations. Twelve samples showed sensitivity at 8 mcg/ml. Eleven samples showed sensitivity at 4 mcg/ml, 8 samples showed sensitivity at 2 mcg/ml, and 5 samples showed sensitivity even at 1 mcg/ml. Mean MIC value of G. lucidum spore powder for P. intermedia obtained was 3.62 mcg/ml. G. lucidum with its multipotential bioactivity could be used as an anti-microbial, in conjunction with conventional therapy in periodontal disease.

  8. Sensitivity and specificity of eustachian tube function tests in adults.

    PubMed

    Doyle, William J; Swarts, J Douglas; Banks, Julianne; Casselbrant, Margaretha L; Mandel, Ellen M; Alper, Cuneyt M

    2013-07-01

    The study demonstrates the utility of eustachian tube (ET) function (ETF) test results for accurately assigning ears to disease state. To determine if ETF tests can identify ears with physician-diagnosed ET dysfunction (ETD) in a mixed population at high sensitivity and specificity and to define the interrelatedness of ETF test parameters. Through use of the forced-response, inflation-deflation, Valsalva, and sniffing tests, ETF was evaluated in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). Data were analyzed using logistic regression including each parameter independently and then a step-down discriminant analysis including all ETF test parameters to predict group assignment. Factor analysis operating over all parameters was used to explore relatedness. ETF testing. ETF parameters for the forced response, inflation-deflation, Valsalva, and sniffing tests measured in 15 control ears of adult subjects after unilateral myringotomy (group 1) and in 23 ears of 19 adult subjects with ventilation tubes inserted for ETD (group 2). The discriminant analysis identified 4 ETF test parameters (Valsalva, ET opening pressure, dilatory efficiency, and percentage of positive pressure equilibrated) that together correctly assigned ears to group 2 at a sensitivity of 95% and a specificity of 83%. Individual parameters representing the efficiency of ET opening during swallowing showed moderately accurate assignments of ears to their respective groups. Three factors captured approximately 98% of the variance among parameters: the first had negative loadings of the ETF structural parameters; the second had positive loadings of the muscle-assisted ET opening parameters; and the third had negative loadings of the muscle-assisted ET opening parameters and positive loadings of the structural parameters. These results show that ETF tests can correctly assign individual ears to physician-diagnosed ETD with high sensitivity and specificity and that ETF test parameters can be grouped into structural-functional categories.

  9. Developmental programming: insulin sensitizer treatment improves reproductive function in prenatal testosterone-treated female sheep.

    PubMed

    Veiga-Lopez, Almudena; Lee, James S; Padmanabhan, Vasantha

    2010-08-01

    Prenatal testosterone (T) excess causes reproductive and metabolic disruptions including insulin resistance, attributes of women with polycystic ovary syndrome. This study tested the hypothesis that insulin resistance contributes toward severity of reproductive disruptions in prenatally T-treated females. Pregnant sheep were injected im with 100 mg of T-propionate semiweekly from d 30-90 of gestation. Immediately after the first breeding season, a subset of controls and prenatal T-treated (TR) sheep were administered an insulin sensitizer (rosiglitazone; 8 mg/d) orally for 8 months. Untreated control and prenatal T-treated females (T group) were studied in parallel. Biochemical analyses revealed rosiglitazone to be safe for use in sheep. Glucose tolerance tests performed before and after the insulin sensitizer treatment found that insulin sensitizer decreased cumulative insulin, cumulative insulin/glucose ratio, and insulin area under the curve by about 50% and increased the insulin sensitivity index by about 70% in the TR compared with the T group. Twenty percent of TR females showed a reduced number of cycles in the second relative to first breeding season as opposed to 80% of T group females showing such deterioration. Insulin sensitizer treatment also decreased the number of aberrant cycles (>/=18 d) during the second breeding season in the TR group relative to the first as opposed to the T group females showing an increase in the second breeding season relative to the first. These findings provide evidence that insulin sensitizer treatment prevents further deterioration of the reproductive axis in prenatal T-treated sheep, a finding of translational relevance to women with polycystic ovary syndrome.

  10. Vibrational Spectroscopic Studies of Reduced-Sensitivity RDX under Static Compression

    NASA Astrophysics Data System (ADS)

    Wong, Chak

    2005-07-01

    Explosives formulations with Reduced- Sensitivity RDX showed reduced shock sensitivity using NOL Large Scale Gap Test, compared with similar formulations using normal RDX. Molecular processes responsible for the reduction of sensitivity are unknown and are crucial for formulation development. Vibrational spectroscopy at static high pressure may shed light to the mechanisms responsible for the reduced shock sensitivity as shown by the NOL Large Scale Gap Test. SIRDX, a form of Reduced- Sensitivity RDX, was subjected to static compression at ambient temperature in a Merrill-Bassett sapphire cell from ambient to about 6 GPa. The spectroscopic techniques used were Raman and Fourier-Transformed IR (FTIR). The pressure dependence of the Raman mode frequencies of SIRDX was determined and compared with that of normal RDX. The behavior of SIRDX near the pressure at which normal RDX, at ambient temperature, undergoes a phase transition from the α to the γ polymorph will be presented. Implications to the reduction in sensitivity will be discussed.

  11. Sensitivity to disinfection of bacterial indicator organisms for monitoring the Salmonella Enteritidis status of layer farms after cleaning and disinfection.

    PubMed

    Dewaele, I; Ducatelle, R; Herman, L; Heyndrickx, M; De Reu, K

    2011-06-01

    The present study evaluated Escherichia coli, Enterococcus faecalis, and Enterococcus hirae as potential indicator organisms for the possible Salmonella Enteritidis (SE) presence in layer farms after cleaning and disinfection by comparing their susceptibility to disinfection. A quantitative suspension disinfection test according to European Standard EN1656 was performed using disinfection products CID20 and Virocid (both from CID Lines, Ieper, Belgium). In a preliminary test, the sensitivity to both disinfection products was compared between ATCC strains of SE, E. coli, En. faecalis, and En. hirae. The sensitivity of SE to disinfection was most comparable to that of E. coli. A second disinfection test compared the elimination of E. coli to SE ATCC strains as well as field strains. Results showed no significant effect regarding the strain (P > 0.05 for CID20 and Virocid), meaning that no difference was detected in sensitivity toward disinfection. When comparing the sensitivity in general at species level for all concentrations of disinfectant used, no significant difference was found between E. coli and SE in sensitivity to Virocid (P > 0.05). In conclusion, because of its similar response to disinfection in a suspension disinfection test, E. coli could be used as an indicator for possible Salmonella presence after cleaning and disinfection.

  12. Is High Resolution Melting Analysis (HRMA) Accurate for Detection of Human Disease-Associated Mutations? A Meta Analysis

    PubMed Central

    Ma, Feng-Li; Jiang, Bo; Song, Xiao-Xiao; Xu, An-Gao

    2011-01-01

    Background High Resolution Melting Analysis (HRMA) is becoming the preferred method for mutation detection. However, its accuracy in the individual clinical diagnostic setting is variable. To assess the diagnostic accuracy of HRMA for human mutations in comparison to DNA sequencing in different routine clinical settings, we have conducted a meta-analysis of published reports. Methodology/Principal Findings Out of 195 publications obtained from the initial search criteria, thirty-four studies assessing the accuracy of HRMA were included in the meta-analysis. We found that HRMA was a highly sensitive test for detecting disease-associated mutations in humans. Overall, the summary sensitivity was 97.5% (95% confidence interval (CI): 96.8–98.5; I2 = 27.0%). Subgroup analysis showed even higher sensitivity for non-HR-1 instruments (sensitivity 98.7% (95%CI: 97.7–99.3; I2 = 0.0%)) and an eligible sample size subgroup (sensitivity 99.3% (95%CI: 98.1–99.8; I2 = 0.0%)). HRMA specificity showed considerable heterogeneity between studies. Sensitivity of the techniques was influenced by sample size and instrument type but by not sample source or dye type. Conclusions/Significance These findings show that HRMA is a highly sensitive, simple and low-cost test to detect human disease-associated mutations, especially for samples with mutations of low incidence. The burden on DNA sequencing could be significantly reduced by the implementation of HRMA, but it should be recognized that its sensitivity varies according to the number of samples with/without mutations, and positive results require DNA sequencing for confirmation. PMID:22194806

  13. Aerobic microbiology and culture sensitivity of head and neck space infection of odontogenic origin

    PubMed Central

    Shah, Amit; Ramola, Vikas; Nautiyal, Vijay

    2016-01-01

    Context: Head and neck space infections source, age, gender, tooth involved, fascial spaces involved, microbiological study of aerobic flora, and antibiotic susceptibilities. Aims: The aim of the present study is to identify causative aerobic microorganisms responsible for deep fascial spaces of head and neck infections and evaluate the resistance of antibiotics used in the treatment of such. Settings and Design: Prospective study in 100 patients. Materials and Methods: This prospective study was conducted on 100 patients who reported in the outpatient department and fulfilled the inclusion criteria to study aerobic microbiology and antibiotic sensitivity in head and neck space infection of odontogenic origin. Pus sample was obtained either by aspiration or by swab stick from the involved spaces, and culture and sensitivity tests were performed. Statistical Analysis Used: Chi-square test and level of significance. Results: Result showed aerobic Gram-positive isolates were 73% and aerobic Gram-negative isolates were 18%. Nine percent cases showed no growth. Streptococcus viridans was the highest isolate in 47% cases among Gram-positive bacteria, and in Gram-negative, Klebsiella pneumoniae was the highest isolate of total cases 11%. Amoxicillin showed resistance (48.4%) as compared to other antibiotics such as ceftriaxone, carbenicillin, amikacin, and imipenem had significantly higher sensitivity. Conclusions: Amoxicillin with clavulanic acid showed (64.8%) efficacy for all organisms isolated, whereas ceftriaxone showed (82.4%) efficacy and could be used in odontogenic infections for both Gram-positive and Gram-negative microorganisms. Substitution of third generation cephalosporin for amoxicillin in the empirical management of deep fascial space infections can also be used. Carbenicillin, amikacin, and imipenem showed (93.4%) sensitivity against all microorganisms and should be reserved for more severe infection. Newer and broad-spectrum antibiotics are more effective in vitro than older narrow spectrum antibiotics. PMID:28163480

  14. Paraneoplastic autoantibody panels: sensitivity and specificity, a retrospective cohort.

    PubMed

    Albadareen, Rawan; Gronseth, Gary; Goeden, Marcie; Sharrock, Matthew; Lechtenberg, Colleen; Wang, Yunxia

    2017-06-01

    Experts in the autoimmune paraneoplastic field recommend autoantibody testing as "panels" to improve the poor sensitivity of individual autoantibodies in detecting paraneoplastic neurological syndromes (PNS). The sensitivity of those panels was not reported to date in a fashion devoid of incorporation bias. We aimed to assess the collective sensitivity and specificity of one of the commonly used panels in detecting PNS. A single-centered retrospective cohort of all patients tested for paraneoplastic evaluation panel (PAVAL; test ID: 83380) over one year for the suspicion of PNS. Case adjudication was based on newly proposed diagnostic criteria in line with previously published literature, but modified to exclude serological status to avoid incorporation bias. Measures of diagnostic accuracy were subsequently calculated. Cases that failed to show association with malignancy within the follow-up time studied, reflecting a possibly pure autoimmune process was considered paraneoplastic-like syndromes. Out of 321 patients tested, 51 patients tested positive. Thirty-two patients met diagnostic criteria for paraneoplastic/paraneoplastic-like syndromes. The calculated collective sensitivity was 34% (95% CI: 17-53), specificity was 86% (95% CI: 81-90), Youden's index 0.2 and a positive clinical utility index 0.07 suggesting poor utility for case-detection. This is the first reported diagnostic accuracy measures of paraneoplastic panels without incorporation bias. Despite recommended panel testing to improve detection of PNS, sensitivity remains low with poor utility for case-detection. The high-calculated specificity suggests a possible role in confirming the condition in difficult cases suspicious for PNS, when enough supportive evidence is lacking on ancillary testing.

  15. A user-operated test of suprathreshold acuity in noise for adult hearing screening: The SUN (Speech Understanding in Noise) test.

    PubMed

    Paglialonga, Alessia; Tognola, Gabriella; Grandori, Ferdinando

    2014-09-01

    A novel, user-operated test of suprathreshold acuity in noise for use in adult hearing screening (AHS) was developed. The Speech Understanding in Noise test (SUN) is a speech-in-noise test that makes use of a list of vowel-consonant-vowel (VCV) stimuli in background noise presented in a three-alternative forced choice (3AFC) paradigm by means of a touch sensitive screen. The test is automated, easy-to-use, and provides self-explanatory results (i.e., 'no hearing difficulties', or 'a hearing check would be advisable', or 'a hearing check is recommended'). The test was developed from its building blocks (VCVs and speech-shaped noise) through two main steps: (i) development of the test list through equalization of the intelligibility of test stimuli across the set and (ii) optimization of the test results through maximization of the test sensitivity and specificity. The test had 82.9% sensitivity and 85.9% specificity compared to conventional pure-tone screening, and 83.8% sensitivity and 83.9% specificity to identify individuals with disabling hearing impairment. Results obtained so far showed that the test could be easily performed by adults and older adults in less than one minute per ear and that its results were not influenced by ambient noise (up to 65dBA), suggesting that the test might be a viable method for AHS in clinical as well as non-clinical settings. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Alcohol consumption promotes mammary tumor growth and insulin sensitivity

    PubMed Central

    Hong, Jina; Holcomb, Valerie B.; Tekle, Samrawit A.; Fan, Betty; Núñez, Nomelí P.

    2010-01-01

    Epidemiological data show that in women, alcohol has a beneficial effect by increasing insulin sensitivity but also a deleterious effect by increasing breast cancer risk. These effects have not been shown concurrently in an animal model of breast cancer. Our objective is to identify a mouse model of breast cancer whereby alcohol increases insulin sensitivity and promotes mammary tumorigenesis. Our results from the glucose tolerance test and the homeostasis model assessment show that alcohol consumption improved insulin sensitivity. However, alcohol-consuming mice developed larger mammary tumors and developed them earlier than water-consuming mice. In vitro results showed that alcohol exposure increased the invasiveness of breast cancer cells in a dose-dependent manner. Thus, this animal model, an in vitro model of breast cancer, may be used to elucidate the mechanism(s) by which alcohol affects breast cancer. PMID:20202743

  17. A new specific ageusia: some humans cannot taste L-glutamate.

    PubMed

    Lugaz, O; Pillias, A-M; Faurion, A

    2002-02-01

    A new specific ageusia was found in human subjects for monosodium L-glutamate (MSG). Four tests were successively applied to discriminate non-tasters and hypotasters from tasters. (i) NaCl and MSG thresholds, and (ii) suprathreshold sensitivity were evaluated using the up-and-down procedure. Only 73% of 109 subjects common to both tests demonstrated a sensitivity for MSG significantly higher than their sensitivity to NaCl, and hence a specific sensitivity to L-glutamate. The remaining 27% who showed no significant difference in sensitivity to MSG and NaCl solutions were considered as putative hypotasters. (iii) Perception profiles (time-intensity) for MSG and NaCl were tested in 58 subjects and appeared significantly different in 47 tasters (81%). This technique helped in identifying among putative hypotasters of tests 1 and 2 a few tasters who perceived equal intensity for isoconcentration of NaCl and MSG but who could discriminate isomolar solutions on other cues. Thus, 19% of subjects, for whom no significant differences were found between MSG and NaCl time-intensity profiles, remained in the hypotaster group. (iv) A discrimination task including 24 triangular presentations per subject of NaCl and MSG 29 mM applied to the eight most severe hypotasters showed that two subjects at least (two of 58; 3.5%) could not discriminate between both stimuli. Moreover, these subjects probably perceived identical sensations for MSG and NaCl solutions. The six other hypotasters (10.3%) could discriminate both stimuli at the limit of significance. None of these eight subjects were able to identify the typical umami taste in 29 mM MSG.

  18. Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods

    NASA Astrophysics Data System (ADS)

    Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab

    2017-10-01

    The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.

  19. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Mai, J.; Tolson, B.

    2017-12-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method's independency of the convergence testing method, we applied it to two widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991) and the variance-based Sobol' method (Solbol' 1993). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an efficient way. The appealing feature of this new technique is the necessity of no further model evaluation and therefore enables checking of already processed sensitivity results. This is one step towards reliable and transferable, published sensitivity results.

  20. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Mai, Juliane; Tolson, Bryan

    2017-04-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters or model processes. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method independency of the convergence testing method, we applied it to three widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991, Campolongo et al., 2000), the variance-based Sobol' method (Solbol' 1993, Saltelli et al. 2010) and a derivative-based method known as Parameter Importance index (Goehler et al. 2013). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. Subsequently, we focus on the model-independency by testing the frugal method using the hydrologic model mHM (www.ufz.de/mhm) with about 50 model parameters. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an efficient way. The appealing feature of this new technique is the necessity of no further model evaluation and therefore enables checking of already processed (and published) sensitivity results. This is one step towards reliable and transferable, published sensitivity results.

  1. Development and evaluation of a truncated recombinant NS3 antigen-based indirect ELISA for detection of pestivirus antibodies in sheep and goats.

    PubMed

    Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya

    2015-01-01

    The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.

  2. Motor and cognitive testing of bone marrow transplant patients after chemoradiotherapy

    NASA Technical Reports Server (NTRS)

    Parth, P.; Dunlap, W. P.; Kennedy, R. S.; Ordy, J. M.; Lane, N. E.

    1989-01-01

    Assessment of cognitive and motor performance of bone marrow transplant patients prior to, during, and following intensive toxic chemoradiotherapy may provide an important adjunct to measures of physiological and medical status. The present study is an attempt to assess whether, as side-effects, these aggressive treatments result in cognitive performance deficits, and if so, whether such changes recover posttreatment. Measurement of cognitive ability in this situation presents special problems not encountered with one-time tests intended for healthy adults. Such tests must be sensitive to changes within a single individual, which emphasizes the crucial importance of high reliability, stability across repeated-measures, and resistance to confounding factors such as motivation and fatigue. The present research makes use of a microbased portable test battery developed to have reliable and sensitive tests which were adapted to study the special requirements of transplant patients who may suffer cognitive deficits as a result of treatment. The results showed slight but significant changes in neuropsychological capacity when compared to baseline levels and controls, particularly near the beginning of treatment. The sensitivity of the battery in detecting such subtle temporary changes is discussed in terms of past research showing effects of other stressors, such as stimulated high altitude and ingestion of alcohol, on these measures.

  3. 11. BUILDING NO. 620B. INTERIOR VIEW LOOKING NORTH, SHOWING PENDULUM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. BUILDING NO. 620-B. INTERIOR VIEW LOOKING NORTH, SHOWING PENDULUM AND FRAME IN FOREGROUND, SHIELD FOR OPERATORS IN BACKGROUND. FRICTION TEST IS OBSERVED FROM BEHIND BLAST SHIELD BY A SERIES OF MIRRORS. ANVIL IN CENTER OF PENDULUM FRAME HOLDS EXPLOSIVE WHOSE SENSITIVITY TO FRICTION IS TO BE TESTED. PANS ON EITHER SIDE CATCH ANY UNBURNT EXPLOSIVE SLUNG FROM ANVIL DURING TEST TO PREVENT EXPLOSIVE HAZARD. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ

  4. Cross-sensitization to Artemisia and Ambrosia pollen allergens in an area located outside of the current distribution range of Ambrosia.

    PubMed

    Grewling, Łukasz; Jenerowicz, Dorota; Bogawski, Paweł; Smith, Matt; Nowak, Małgorzata; Frątczak, Agata; Czarnecka-Operacz, Magdalena

    2018-02-01

    The role of long-distance transported (LDT) Ambrosia pollen in inducing new sensitization and affecting sensitization rates in Artemisia -sensitized patients is unclear. The aim of this study was to estimate the degree of cross-sensitization to Ambrosia/Artemisi a allergens in citizens of Poznan (Western Poland). This area is covered by extensive Artemisia populations but does not currently have local Ambrosia populations. Sera of 119 patients were tested by fluoroenzyme immunoassay (CAP-FEIA system) against pollen allergen extracts of Artemisia vulgaris and Ambrosia artemisiifolia , an allergenic component of A. vulgaris ( nArt v 1 ), and an allergenic component of A. artemisiifolia ( nAmb a 1 ). Skin prick tests (SPTs, n = 86) were performed with pollen allergen extracts of A. vulgaris and A. artemisiifolia . Artemisia and Ambrosia pollen in ambient air was collected (1996-2013) by a Hirst type volumetric trap sited at roof level (33 m). The SPT showed that the prevalence of sensitization to Ambrosia and Artemisia pollen exceeded 3.5%, and 10.5%, respectively. The measurements of IgE in blood serum (CAP-FEIA) revealed that among Ambrosia -sensitized patients 90.1% (20/22 patients) were concomitantly sensitized to Artemisia . 59.1% (13/22) of these patients reacted to nArt v 1 , suggesting primary sensitization to Artemisia pollen. Only 2 (9.1%) patients were mono-sensitized to Ambrosia pollen extract, but surprisingly not to nAmb a 1 . The LDT Ambrosia pollen had a negligible effect on the rate of sensitization to Ambrosia allergens in Poznan and did not increase the prevalence of sensitization to Artemisia pollen in this region. However, the majority of patients showing hypersensitization to Artemisia pollen might also present symptoms during elevated episodes of LDT of Ambrosia pollen.

  5. Limonene hydroperoxide analogues show specific patch test reactions.

    PubMed

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. [Value of desmopressin stimulation test and high dose dexamethasone suppression testin the etiologic diagnosis of ACTH dependent Cushing's syndrome].

    PubMed

    Zhang, Weiwei; Yu, Yerong; Tan, Huiwen; Wang, Chun; Li, Jianwei; An, Zhenmei; Liu, Yuping

    2016-03-22

    To investigate the value of desmopressin (DDAVP) stimulation test and high dose dexamethasone suppression test (HDDST) in establishing the cause of ACTH dependent Cushing's syndrome. The clinical data of patients with ACTH dependent Cushing's syndrome at West China Hospital from January 1, 2010 to September 30, 2015 was analyzed. The sensitivity and specificity of DDAVP stimulation test, HDDST, and the diagnostic accordance rate when the two tests were combined, were evaluated based on the diagnostic gold standard. A total of 85 patients with Cushing's disease and 10 patients with ectopic ACTH syndrome were included. The sensitivity and specificity of DDAVP stimulation test were 87% and 5/5, respectively, whereas those of HDDST were 79% and 8/10, respectively. The standard high dose dexamethasone suppression test showed a higher sensitivity than overnight 8 mg dexamethasone suppression test. When the two tests had consistent results, the diagnostic accordance rate was 100%. DDAVP stimulation test and HDDST are both efficient modalities for the diagnosis of Cushing's Disease and ectopic ACTH syndrome. The accuracy of diagnosis can be further improved by combining the two tests.

  7. Use of genotoxicity information in the development of integrated testing strategies (ITS) for skin sensitization.

    PubMed

    Mekenyan, Ovanes; Patlewicz, Grace; Dimitrova, Gergana; Kuseva, Chanita; Todorov, Milen; Stoeva, Stoyanka; Kotov, Stefan; Donner, E Maria

    2010-10-18

    Skin sensitization is an end point of concern for various legislation in the EU, including the seventh Amendment to the Cosmetics Directive and Registration Evaluation, Authorisation and Restriction of Chemicals (REACH). Since animal testing is a last resort for REACH or banned (from 2013 onward) for the Cosmetics Directive, the use of intelligent/integrated testing strategies (ITS) as an efficient means of gathering necessary information from alternative sources (e.g., in vitro, (Q)SARs, etc.) is gaining widespread interest. Previous studies have explored correlations between mutagenicity data and skin sensitization data as a means of exploiting information from surrogate end points. The work here compares the underlying chemical mechanisms for mutagenicity and skin sensitization in an effort to evaluate the role mutagenicity information can play as a predictor of skin sensitization potential. The Tissue Metabolism Simulator (TIMES) hybrid expert system was used to compare chemical mechanisms of both end points since it houses a comprehensive set of established structure-activity relationships for both skin sensitization and mutagenicity. The evaluation demonstrated that there is a great deal of overlap between skin sensitization and mutagenicity structural alerts and their underlying chemical mechanisms. The similarities and differences in chemical mechanisms are discussed in light of available experimental data. A number of new alerts for mutagenicity were also postulated for inclusion into TIMES. The results presented show that mutagenicity information can provide useful insights on skin sensitization potential as part of an ITS and should be considered prior to any in vivo skin sensitization testing being initiated.

  8. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    PubMed

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  9. Evaluation of mysids and sea urchins exposed to saxitoxins.

    PubMed

    Bernardi Bif, Mariana; Yunes, João Sarkis; Resgalla, Charrid

    2013-11-01

    Saxitoxins are neurotoxins produced by dinoflagellates and cyanobacteria that form toxic blooms in waters. The impact of saxitoxins to the most vulnerable taxa and environment are not well understood. The experimental model was based on the use of toxic cell extracts containing saxitoxins. This extract was utilized for acute and chronic tests with Mysidopsis juniae. Chronic tests were also done with Lytechinus variegatus and Arbacia lixula larvae. Acute test with mysids had a LC₅₀=2.34 μg/L. The chronic test with sea urchins showed morphological abnormalities resulting in malformation of larval appendices at low concentrations of the toxin (EC₅₀=2.96 μg/L for L. variegatus and 2.06 μg/L for A. lixula). Although saxitoxins are considered neurotoxins, both species of sea urchins showed symptoms not related to nerve cells. A. lixula was more sensitive than L. variegatus, proving that its sensitivity should be taken in consideration to be another option to toxicological tests. Copyright © 2013. Published by Elsevier B.V.

  10. A goodness-of-fit test for capture-recapture model M(t) under closure

    USGS Publications Warehouse

    Stanley, T.R.; Burnham, K.P.

    1999-01-01

    A new, fully efficient goodness-of-fit test for the time-specific closed-population capture-recapture model M(t) is presented. This test is based on the residual distribution of the capture history data given the maximum likelihood parameter estimates under model M(t), is partitioned into informative components, and is based on chi-square statistics. Comparison of this test with Leslie's test (Leslie, 1958, Journal of Animal Ecology 27, 84- 86) for model M(t), using Monte Carlo simulations, shows the new test generally outperforms Leslie's test. The new test is frequently computable when Leslie's test is not, has Type I error rates that are closer to nominal error rates than Leslie's test, and is sensitive to behavioral variation and heterogeneity in capture probabilities. Leslie's test is not sensitive to behavioral variation in capture probabilities but, when computable, has greater power to detect heterogeneity than the new test.

  11. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia.

    PubMed

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-09-01

    Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.

  12. Sensitivity and specificity of the Eating Assessment Tool and the Volume-Viscosity Swallow Test for clinical evaluation of oropharyngeal dysphagia

    PubMed Central

    Rofes, L; Arreola, V; Mukherjee, R; Clavé, P

    2014-01-01

    Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661

  13. Performance of a HRP-2/pLDH based rapid diagnostic test at the Bangladesh-India-Myanmar border areas for diagnosis of clinical malaria.

    PubMed

    Elahi, Rubayet; Mohon, Abu Naser; Khan, Wasif A; Haque, Rashidul; Alam, Mohammad Shafiul

    2013-10-30

    The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Parascreen® Pan/Pf) in a laboratory setting utilizing clinical samples obtained from the field. Whole blood samples were obtained from febrile patients referred for malaria diagnosis by clinicians from two different Upazila Health Complexes (UHCs) located near the Bangladesh-India and Bangladesh-Myanmar border where malaria is endemic. RDT was performed on archived samples and sensitivity and specificity evaluated with expert microscopy (EM) and quantitative PCR (qPCR). A total of 327 clinical samples were made available for the study, of which 153 were Plasmodium falciparum-positive and 54 were Plasmodium vivax-positive. In comparison with EM, for P. falciparum malaria, the RDT had sensitivity: 96.0% (95% CI, 91.2-98.3) and specificity: 98.2% (95% CI, 94.6-99.5) and for P. vivax, sensitivity: 90.7% (95% CI, 78.9-96.5) and specificity: 98.9% (95% CI, 96.5-99.7). Comparison with qPCR showed, for P. falciparum malaria, sensitivity: 95.4% (95% CI, 90.5-98.0) and specificity: 98.8% (95% CI, 95.4-99.7) and for P. vivax malaria, sensitivity: 89.0% (95% CI,77.0-95.4) and specificity: 98.8% (95% CI, 96.5-99.7). Sensitivity varied according to different parasitaemia for falciparum and vivax malaria diagnosis. Parascreen® Pan/Pf Rapid test for malaria showed acceptable sensitivity and specificity in border belt endemic areas of Bangladesh when compared with EM and qPCR.

  14. Digital Rectal Examination and Balloon Expulsion Test in the Study of Defecatory Disorders: Are They Suitable as Screening or Excluding Tests?

    PubMed

    Caetano, Ana C; Santa-Cruz, André; Rolanda, Carla

    2016-01-01

    Background . Rome III criteria add physiological criteria to symptom-based criteria of chronic constipation (CC) for the diagnosis of defecatory disorders (DD). However, a gold-standard test is still lacking and physiological examination is expensive and time-consuming. Aim . Evaluate the usefulness of two low-cost tests-digital rectal examination (DRE) and balloon expulsion test (BET)-as screening or excluding tests of DD. Methods . We performed a systematic search in PUBMED and MEDLINE. We selected studies where constipated patients were evaluated by DRE or BET. Heterogeneity was assessed and random effect models were used to calculate the sensitivity, specificity, and negative predictive value (NPV) of the DRE and the BET. Results . Thirteen studies evaluating BET and four studies evaluating DRE (2329 patients) were selected. High heterogeneity ( I 2 > 80%) among studies was demonstrated. The studies evaluating the BET showed a sensitivity and specificity of 67% and 80%, respectively. Regarding the DRE, a sensitivity of 80% and specificity of 84% were calculated. NPV of 72% for the BET and NPV of 64% for the DRE were estimated. The sensitivity and specificity were similar when we restrict the analysis to studies using Rome criteria to define CC. The BET seems to perform better when a cut-off time of 2 minutes is used and when it is compared with a combination of physiological tests. Considering the DRE, strict criteria seem to improve the sensitivity but not the specificity of the test. Conclusion . Neither of the low-cost tests seems suitable for screening or excluding DD.

  15. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    PubMed

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Effect of chitosan on hyphal growth and spore germination of plant pathogenic and biocontrol fungi.

    PubMed

    Palma-Guerrero, J; Jansson, H-B; Salinas, J; Lopez-Llorca, L V

    2008-02-01

    To investigate the toxic effect of chitosan on important root pathogenic and biocontrol fungi (nematophagous, entomopathogenic and mycoparasitic). We have used standard bioassays to investigate the effect of chitosan on colony growth and developed bioassays to test spore germination. The results showed that the root pathogenic and mycoparasitic fungi tested were more sensitive to chitosan than nematophagous and entomopathogenic fungi. Chitosanases (and perhaps related enzymes) are involved in the resistance to chitosan. Two fungi, one sensitive to chitosan, Fusarium oxysporum f. sp. radicis-lycopersici, and one less sensitive, Pochonia chlamydosporia, were selected for ultrastructural investigations. Transmission electron microscopy revealed differences in the ultrastructural alterations caused by chitosan in the spores of the plant pathogenic fungus and in those of the nematophagous fungus. Confocal laser microscopy showed that Rhodamine-labelled chitosan enters rapidly into conidia of both fungi, in an energy-dependent process. Nematophagous and entomopathogenic fungi are rather resistant to the toxic effect of chitosan. Resistance of nematophagous and entomopathogenic fungi to chitosan could be associated with their high extracellular chitosanolytic activity. Furthermore, ultrastructural damage is much more severe in the chitosan sensitive fungus. The results of this paper suggest that biocontrol fungi tested could be combined with chitosan for biological control of plant pathogens and pests.

  17. Equal Opportunity in the Classroom: Test Construction in a Diversity-Sensitive Environment.

    ERIC Educational Resources Information Center

    Ghorpade, Jai; Lackritz, James R.

    1998-01-01

    Two multiple-choice tests and one essay test were taken by 231 students (50/50 male/female, 192 White, 39 East Asian, Black, Mexican American, or Middle Eastern). Multiple-choice tests showed no significant differences in equal employment opportunity terms; women and men scored about the same on essays, but minority students had significantly…

  18. Obesity-resistant S5B rats showed great cocaine conditioned place preference than the obesity-prone OM rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thanos, P.K.; Wang, G.; Thanos, P.K..

    Dopamine (DA) and the DA D2 receptor (D2R) are involved in the rewarding and conditioned responses to food and drug rewards. Osborne-Mendel (OM) rats are genetically prone and S5B/P rats are genetically resistant to obesity when fed a high-fat diet. We hypothesized that the differential sensitivity of these two rat strains to natural rewards may also be reflected in sensitivity to drugs of abuse. Therefore, we tested whether OM and S5B/P rats showed a differential preference to cocaine using conditioned place preference (CPP). To also evaluate whether there is specific involvement of the D2R in this differential conditioning sensitivity, wemore » then tested whether the D2R agonist bromocriptine (BC) would differentially affect the effects of cocaine in the two strains. OM and S5B/P rats were conditioned with cocaine (5 or 10 mg/kg) in one chamber and saline in another for 8 days. Rats were then tested for cocaine preference. The effects of BC (0.5, 1, 5, 10, 20 mg/kg) on cocaine preference were then assessed in subsequent test sessions. OM rats did not show a significant preference for the cocaine-paired chamber on test day. Only the S5B/P rats showed cocaine CPP. Later treatment with only the highest dose of BC resulted in reduced cocaine CPP in S5B/P rats when treated with 5 mg/kg cocaine and in OM rats treated with 10 mg/kg cocaine. Our results indicated that obesity-resistant S5B rats showed greater cocaine CPP than the obesity-prone OM rats. These findings do not support a theory of common vulnerability for reinforcer preferences (food and cocaine). However, they show that BC reduced cocaine conditioning effects supporting at least a partial regulatory role of D2R in conditioned responses to drugs.« less

  19. Direct detection of Leishmania from clinical samples.

    PubMed

    Waitumbi, John N; Bast, Joshua; Nyakoe, Nancy; Magiri, Charles; Quintana, Miguel; Takhampunya, Ratree; Schuster, Anthony L; Van de Wyngaerde, Marshall T; McAvin, James C; Coleman, Russell E

    2017-01-01

    The ability to rapidly and accurately diagnose leishmaniasis is a military priority. Testing was conducted to evaluate diagnostic sensitivity and specificity of field-expedient Leishmania genus and visceral Leishmania specific dual-fluorogenic, hydrolysis probe (TaqMan), polymerase chain reaction assays previously established for use in vector surveillance. Blood samples of patients with confirmed visceral leishmaniasis and controls without the disease from Baringo District, Kenya, were tested. Leishmania genus assay sensitivity was 100% (14/14) and specificity was 84% (16/19). Visceral Leishmania assay sensitivity was 93% (13/14) and specificity 80% (4/5). Cutaneous leishmaniasis (CL) skin scrapes of patients from Honduras were also evaluated. Leishmania genus assay sensitivity was 100% (10/10). Visceral Leishmania assay specificity was 100% (10/10) from cutaneous leishmaniasis samples; no fluorescence above background was reported. These results show promise in a rapid, sensitive, and specific method for Leishmania direct detection from clinical samples.

  20. Accuracy of prospective memory tests in mild Alzheimer's disease.

    PubMed

    Martins, Sergilaine Pereira; Damasceno, Benito Pereira

    2012-01-01

    To verify the accuracy of prospective memory (ProM) tests in Alzheimer's disease (AD). Twenty mild AD patients (CDR 1), and 20 controls underwent Digit Span (DS), Trail Making (TM) A and B, visual perception, Rey Auditory-Verbal Learning tests, and Cornell Scale for Depression. AD diagnosis was based on DSM-IV and NINCDS-ADRDA criteria. ProM was assessed with the appointment and belonging subtests of Rivermead Behavioral Memory Test (RBMT); and with two new tests (the clock and animal tests). AD patients had a worse performance than controls on the majority of tests, except DS forward and TM-A. There was no correlation between RBMT and the new ProM tests. As for accuracy, the only significant difference concerned the higher sensitivity of our animal test versus the RBMT belonging test. The clock and the animal tests showed similar specificity, but higher sensitivity than the RBMT subtests.

  1. Development of reverse transcription-PCR assays specific for detection of equine encephalitis viruses.

    PubMed

    Linssen, B; Kinney, R M; Aguilar, P; Russell, K L; Watts, D M; Kaaden, O R; Pfeffer, M

    2000-04-01

    Specific and sensitive reverse transcription-PCR (RT-PCR) assays were developed for the detection of eastern, western, and Venezuelan equine encephalitis viruses (EEE, WEE, and VEE, respectively). Tests for specificity included all known alphavirus species. The EEE-specific RT-PCR amplified a 464-bp region of the E2 gene exclusively from 10 different EEE strains from South and North America with a sensitivity of about 3,000 RNA molecules. In a subsequent nested PCR, the specificity was confirmed by the amplification of a 262-bp fragment, increasing the sensitivity of this assay to approximately 30 RNA molecules. The RT-PCR for WEE amplified a fragment of 354 bp from as few as 2,000 RNA molecules. Babanki virus, as well as Mucambo and Pixuna viruses (VEE subtypes IIIA and IV), were also amplified. However, the latter viruses showed slightly smaller fragments of about 290 and 310 bp, respectively. A subsequent seminested PCR amplified a 195-bp fragment only from the 10 tested strains of WEE from North and South America, rendering this assay virus specific and increasing its sensitivity to approximately 20 RNA molecules. Because the 12 VEE subtypes showed too much divergence in their 26S RNA nucleotide sequences to detect all of them by the use of nondegenerate primers, this assay was confined to the medically important and closely related VEE subtypes IAB, IC, ID, IE, and II. The RT-PCR-seminested PCR combination specifically amplified 342- and 194-bp fragments of the region covering the 6K gene in VEE. The sensitivity was 20 RNA molecules for subtype IAB virus and 70 RNA molecules for subtype IE virus. In addition to the subtypes mentioned above, three of the enzootic VEE (subtypes IIIB, IIIC, and IV) showed the specific amplicon in the seminested PCR. The practicability of the latter assay was tested with human sera gathered as part of the febrile illness surveillance in the Amazon River Basin of Peru near the city of Iquitos. All of the nine tested VEE-positive sera showed the expected 194-bp amplicon of the VEE-specific RT-PCR-seminested PCR.

  2. Simulator study of conventional general aviation instrument displays in path-following tasks with emphasis on pilot-induced oscillations

    NASA Technical Reports Server (NTRS)

    Adams, J. J.

    1980-01-01

    A study of the use of conventional general aviation instruments by general aviation pilots in a six degree of freedom, fixed base simulator was conducted. The tasks performed were tracking a VOR radial and making an ILS approach to landing. A special feature of the tests was that the sensitivity of the displacement indicating instruments (the RMI, CDI, and HSI) was kept constant at values corresponding to 5 n. mi. and 1.25 n. mi. from the station. Both statistical and pilot model analyses of the data were made. The results show that performance in path following improved with increases in display sensitivity up to the highest sensitivity tested. At this maximum test sensitivity, which corresponds to the sensitivity existing at 1.25 n. mi. for the ILS glide slope transmitter, tracking accuracy was no better than it was at 5 n. mi. from the station and the pilot aircraft system exhibited a marked reduction in damping. In some cases, a pilot induced, long period unstable oscillation occurred.

  3. Left gastric vein-based noninvasive test for esophageal varices: a same-day comparison of portal hemodynamic assessment with endoscopic appearance.

    PubMed

    Maruyama, Hitoshi; Kobayashi, Kazufumi; Kiyono, Soichiro; Ogasawara, Sadahisa; Ooka, Yoshihiko; Suzuki, Eiichiro; Chiba, Tetsuhiro; Kato, Naoya

    2018-05-25

    To examine the effect of hemodynamic assessment of the left gastric vein (LGV) as a noninvasive test to diagnose esophageal varices (EV) in cirrhosis patients. This cross-sectional study consisted of 229 cirrhosis patients (62.7 ± 11.8 years; Child-Pugh score 5-14). One hundred fifty-four patients had EV (67.2%; small, 53; medium, 71; large, 30). All patients underwent a blood test and Doppler ultrasound followed by upper gastrointestinal endoscopy on the same day. The diagnostic ability for EV was compared between LGV-related findings and the platelet count/spleen diameter ratio (Plt/Spl). The detectability of the LGV was higher in patients with EV (129/144, 89.6%) than in those without (35/75, 46.7%; p < 0.0001), and was higher in those with large EV (30/30, 100%) than in those without (134/199, 67.3%; p = 0.0002). The positive detection of the LGV showed 100% sensitivity and negative predictive value (NPV) to identify large EV in the whole cohort and compensated group (n = 127). The best cutoff value in the LGV diameter was 5.35 mm to identify large EV, showing 0.753 area under the receiver operating characteristic curve (AUROC) with 90% sensitivity and 96.5% NPV. The Plt/Spl showed 62.1% sensitivity and 87.1% NPV, and the best cutoff value was 442.9 to identify large EV with 0.658 AUROC, which was comparable to LGV-based assessment (p = 0.162). This same-day comparison study demonstrated the value of LGV-based noninvasive test to identify large EV with high sensitivity and NPV in cirrhosis patients at a lower cost.

  4. Continuous coaxial cable sensors for monitoring of RC structures with electrical time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Chen, Genda; Mu, Huimin; Pommerenke, David; Drewniak, James L.

    2003-08-01

    This study was aimed at developing and validating a new type of coaxial cable sensors that can be used to detect cracks or measure strains in reinforced concrete (RC) structures. The new sensors were designed based on the change in outer conductor configuration under strain effects in contrast to the geometry-based design in conventional coaxial cable sensors. Both numerical simulations and calibration tests with strain gauges of a specific design of the proposed cables were conducted to study the cables' sensitivity. Four designs of the proposed type of sensors were then respectively mounted near the surface of six 3-foot-long RC beams. They were tested in bending to further validate the cables' sensitivity in concrete members. The calibration test results generally agree with the numerical simulations. They showed that the proposed sensors are over 10~50 times more sensitive than conventional cable sensors. The test results of the beams not only validate the sensitivity of the new sensors but also indicate a good correlation with the measured crack width.

  5. Urchin-like gold nanoparticle-based immunochromatographic strip test for rapid detection of fumonisin B1 in grains.

    PubMed

    Ren, Wenjie; Huang, Zhibing; Xu, Yang; Li, Yanping; Ji, Yanwei; Su, Baowei

    2015-09-01

    An immunochromatographic strip (ICS) using urchin-like gold nanoparticles (UGNs) for sensitive detection of fumonisin B1 (FB1) was developed to meet the requirement for rapidly monitoring FB1 in grain samples. The sensitivity of the ICS was 5.0 ng/mL, which represents a fourfold increase in sensitivity over conventional strip preparation using colloidal gold as the antibody-labeled probe. Analysis of FB1 in grain samples showed that data obtained from the strip tests were in a good agreement with those obtained from HPLC and enzyme-linked immunosorbent assays (ELISAs). This qualitative test did not require any specialized equipment, and the detection time was less than 5 min, which is suitable for on-site testing of FB1 in grain samples. Overall, to our knowledge, this is the first report of using a UGN as the antibody-labeled probe for sensitive detection of FB1 in grains using an ICS. Graphical Abstract Preparation of ICS using conventional colloidal gold and urchin-like gold nanoparticle, respectively.

  6. 76 FR 12873 - Potassium Benzoate; Exemption From the Requirement of a Tolerance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... (preservative) in pesticide formulations applied pre- and post-harvest. In the Federal Register of June 4, 2008... the relationship of the results of the studies to human risk. EPA has also considered available... were non-sensitizing in animal tests but showed a very low incidence of sensitization in humans patch...

  7. Method Matters: Systematic Effects of Testing Procedure on Visual Working Memory Sensitivity

    ERIC Educational Resources Information Center

    Makovski, Tal; Watson, Leah M.; Koutstaal, Wilma; Jiang, Yuhong V.

    2010-01-01

    Visual working memory (WM) is traditionally considered a robust form of visual representation that survives changes in object motion, observer's position, and other visual transients. This article presents data that are inconsistent with the traditional view. We show that memory sensitivity is dramatically influenced by small variations in the…

  8. The Major Soybean Allergen Gly m Bd 28K Induces Hypersensitivity Reactions in Mice Sensitized to Cow's Milk Proteins.

    PubMed

    Candreva, Ángela María; Smaldini, Paola Lorena; Curciarello, Renata; Fossati, Carlos Alberto; Docena, Guillermo Horacio; Petruccelli, Silvana

    2016-02-24

    Reactions to soy have been reported in a proportion of patients with IgE-mediated cow's milk allergy (CMA). In this work, we analyzed if Gly m Bd 28K/P28, one of the major soybean allergens, is a cross-reactive allergen with cow milk proteins (CMP). We showed that P28 was recognized by IgE sera from CMA patients and activated human peripheral basophils degranulation. Moreover, IgE sera of mice exclusively sensitized to CMP recognized P28. Splenocytes from sensitized animals secreted IL-5 and IL-13 when incubated with CMP or soy proteins, but only IL-13 when treated with P28. In addition, a skin test was strongly positive for CMP and weakly positive for P28. Remarkably, milk-sensitized mice showed hypersensitivity symptoms following sublingual challenge with P28 or CMP. With the use of bioinformatics' tools seven putative cross-reactive epitopes were identified. In conclusion, using in vitro and in vivo tests we demonstrated that P28 is a novel cross-reactive allergen with CMP.

  9. Towards more accurate HIV testing in sub-Saharan Africa: a multi-site evaluation of HIV RDTs and risk factors for false positives

    PubMed Central

    Kosack, Cara S; Page, Anne-Laure; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Shanks, Leslie; Fransen, Katrien

    2017-01-01

    Abstract Introduction: Although individual HIV rapid diagnostic tests (RDTs) show good performance in evaluations conducted by WHO, reports from several African countries highlight potentially significant performance issues. Despite widespread use of RDTs for HIV diagnosis in resource-constrained settings, there has been no systematic, head-to-head evaluation of their accuracy with specimens from diverse settings across sub-Saharan Africa. We conducted a standardized, centralized evaluation of eight HIV RDTs and two simple confirmatory assays at a WHO collaborating centre for evaluation of HIV diagnostics using specimens from six sites in five sub-Saharan African countries. Methods: Specimens were transported to the Institute of Tropical Medicine (ITM), Antwerp, Belgium for testing. The tests were evaluated by comparing their results to a state-of-the-art reference algorithm to estimate sensitivity, specificity and predictive values. Results: 2785 samples collected from August 2011 to January 2015 were tested at ITM. All RDTs showed very high sensitivity, from 98.8% for First Response HIV Card Test 1–2.0 to 100% for Determine HIV 1/2, Genie Fast, SD Bioline HIV 1/2 3.0 and INSTI HIV-1/HIV-2 Antibody Test kit. Specificity ranged from 90.4% for First Response to 99.7% for HIV 1/2 STAT-PAK with wide variation based on the geographical origin of specimens. Multivariate analysis showed several factors were associated with false-positive results, including gender, provider-initiated testing and the geographical origin of specimens. For simple confirmatory assays, the total sensitivity and specificity was 100% and 98.8% for ImmunoComb II HIV 12 CombFirm (ImmunoComb) and 99.7% and 98.4% for Geenius HIV 1/2 with indeterminate rates of 8.9% and 9.4%. Conclusions: In this first systematic head-to-head evaluation of the most widely used RDTs, individual RDTs performed more poorly than in the WHO evaluations: only one test met the recommended thresholds for RDTs of ≥99% sensitivity and ≥98% specificity. By performing all tests in a centralized setting, we show that these differences in performance cannot be attributed to study procedure, end-user variation, storage conditions, or other methodological factors. These results highlight the existence of geographical and population differences in individual HIV RDT performance and underscore the challenges of designing locally validated algorithms that meet the latest WHO-recommended thresholds. PMID:28364560

  10. Sensitivity of Amoxicillin-Resistant Helicobacter pylori to Other Penicillins

    PubMed Central

    Dore, Maria P.; Graham, David Y.; Sepulveda, Antonia R.; Realdi, Giuseppe; Osato, Michael S.

    1999-01-01

    The sensitivities to penicillins and to a penicillin and β-lactamase inhibitor combination agent were determined for Helicobacter pylori strains that were sensitive, moderately resistant, or highly resistant to amoxicillin. All strains were resistant to nafcillin and oxacillin. Moderately resistant strains showed an intermediate zone of inhibition to ticarcillin, mezlocillin, piperacillin, and amoxicillin-clavulanic acid. High-level resistance was associated with the smallest zone size for all penicillins tested. PMID:10390249

  11. Sensitivity and specificity of the Streptococcus pneumoniae urinary antigen test for unconcentrated urine from adult patients with pneumonia: a meta-analysis.

    PubMed

    Horita, Nobuyuki; Miyazawa, Naoki; Kojima, Ryota; Kimura, Naoko; Inoue, Miyo; Ishigatsubo, Yoshiaki; Kaneko, Takeshi

    2013-11-01

    Studies on the sensitivity and specificity of the Binax Now Streptococcus pneumonia urinary antigen test (index test) show considerable variance of results. Those written in English provided sufficient original data to evaluate the sensitivity and specificity of the index test using unconcentrated urine to identify S. pneumoniae infection in adults with pneumonia. Reference tests were conducted with at least one culture and/or smear. We estimated sensitivity and two specificities. One was the specificity evaluated using only patients with pneumonia of identified other aetiologies ('specificity (other)'). The other was the specificity evaluated based on both patients with pneumonia of unknown aetiology and those with pneumonia of other aetiologies ('specificity (unknown and other)') using a fixed model for meta-analysis. We found 10 articles involving 2315 patients. The analysis of 10 studies involving 399 patients yielded a pooled sensitivity of 0.75 (95% confidence interval: 0.71-0.79) without heterogeneity or publication bias. The analysis of six studies involving 258 patients yielded a pooled specificity (other) of 0.95 (95% confidence interval: 0.92-0.98) without no heterogeneity or publication bias. We attempted to conduct a meta-analysis with the 10 studies involving 1916 patients to estimate specificity (unknown and other), but it remained unclear due to moderate heterogeneity and possible publication bias. In our meta-analysis, sensitivity of the index test was moderate and specificity (other) was high; however, the specificity (unknown and other) remained unclear. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  12. Sibship size, sibling cognitive sensitivity, and children's receptive vocabulary.

    PubMed

    Prime, Heather; Pauker, Sharon; Plamondon, André; Perlman, Michal; Jenkins, Jennifer

    2014-02-01

    The aim of the current study was to examine the relationship between sibship size and children's vocabulary as a function of quality of sibling interactions. It was hypothesized that coming from a larger sibship (ie, 3+ children) would be related to lower receptive vocabulary in children. However, we expected this association to be moderated by the level of cognitive sensitivity shown by children's next-in-age older siblings. Data on 385 children (mean age = 3.15 years) and their next-in-age older siblings (mean age = 5.57 years) were collected and included demographic questionnaires, direct testing of children's receptive vocabulary, and videos of mother-child and sibling interactions. Sibling dyads were taped engaging in a cooperative building task and tapes were coded for the amount of cognitive sensitivity the older sibling exhibited toward the younger sibling. Hierarchical regression analyses were conducted and showed an interaction between sibship size and sibling cognitive sensitivity in the prediction of children's receptive vocabulary; children exposed to large sibships whose next-in-age older sibling exhibited higher levels of cognitive sensitivity were less likely to show low vocabulary skills when compared with those children exposed to large sibships whose siblings showed lower levels of cognitive sensitivity. Children who show sensitivity to the cognitive needs of their younger siblings provide a rich environment for language development. The negative impact of large sibships on language development is moderated by the presence of an older sibling who shows high cognitive sensitivity.

  13. PCR Inhibition of a Quantitative PCR for Detection of Mycobacterium avium Subspecies Paratuberculosis DNA in Feces: Diagnostic Implications and Potential Solutions

    PubMed Central

    Acharya, Kamal R.; Dhand, Navneet K.; Whittington, Richard J.; Plain, Karren M.

    2017-01-01

    Molecular tests such as polymerase chain reaction (PCR) are increasingly being applied for the diagnosis of Johne’s disease, a chronic intestinal infection of ruminants caused by Mycobacterium avium subspecies paratuberculosis (MAP). Feces, as the primary test sample, presents challenges in terms of effective DNA isolation, with potential for PCR inhibition and ultimately for reduced analytical and diagnostic sensitivity. However, limited evidence is available regarding the magnitude and diagnostic implications of PCR inhibition for the detection of MAP in feces. This study aimed to investigate the presence and diagnostic implications of PCR inhibition in a quantitative PCR assay for MAP (High-throughput Johne’s test) to investigate the characteristics of samples prone to inhibition and to identify measures that can be taken to overcome this. In a study of fecal samples derived from a high prevalence, endemically infected cattle herd, 19.94% of fecal DNA extracts showed some evidence of inhibition. Relief of inhibition by a five-fold dilution of the DNA extract led to an average increase in quantification of DNA by 3.3-fold that consequently increased test sensitivity of the qPCR from 55 to 80% compared to fecal culture. DNA extracts with higher DNA and protein content had 19.33 and 10.94 times higher odds of showing inhibition, respectively. The results suggest that the current test protocol is sensitive for herd level diagnosis of Johne’s disease but that test sensitivity and individual level diagnosis could be enhanced by relief of PCR inhibition, achieved by five-fold dilution of the DNA extract. Furthermore, qualitative and quantitative parameters derived from absorbance measures of DNA extracts could be useful for prediction of inhibitory fecal samples. PMID:28210245

  14. Accuracy of parasitological and immunological tests for the screening of human schistosomiasis in immigrants and refugees from African countries: An approach with Latent Class Analysis

    PubMed Central

    Beltrame, Anna; Guerriero, Massimo; Angheben, Andrea; Gobbi, Federico; Requena-Mendez, Ana; Zammarchi, Lorenzo; Formenti, Fabio; Perandin, Francesca; Bisoffi, Zeno

    2017-01-01

    Background Schistosomiasis is a neglected infection affecting millions of people, mostly living in sub-Saharan Africa. Morbidity and mortality due to chronic infection are relevant, although schistosomiasis is often clinically silent. Different diagnostic tests have been implemented in order to improve screening and diagnosis, that traditionally rely on parasitological tests with low sensitivity. Aim of this study was to evaluate the accuracy of different tests for the screening of schistosomiasis in African migrants, in a non endemic setting. Methodology/Principal findings A retrospective study was conducted on 373 patients screened at the Centre for Tropical Diseases (CTD) in Negrar, Verona, Italy. Biological samples were tested with: stool/urine microscopy, Circulating Cathodic Antigen (CCA) dipstick test, ELISA, Western blot, immune-chromatographic test (ICT). Test accuracy and predictive values of the immunological tests were assessed primarily on the basis of the results of microscopy (primary reference standard): ICT and WB resulted the test with highest sensitivity (94% and 92%, respectively), with a high NPV (98%). CCA showed the highest specificity (93%), but low sensitivity (48%). The analysis was conducted also using a composite reference standard, CRS (patients classified as infected in case of positive microscopy and/or at least 2 concordant positive immunological tests) and Latent Class Analysis (LCA). The latter two models demonstrated excellent agreement (Cohen’s kappa: 0.92) for the classification of the results. In fact, they both confirmed ICT as the test with the highest sensitivity (96%) and NPV (97%), moreover PPV was reasonably good (78% and 72% according to CRS and LCA, respectively). ELISA resulted the most specific immunological test (over 99%). The ICT appears to be a suitable screening test, even when used alone. Conclusions The rapid test ICT was the most sensitive test, with the potential of being used as a single screening test for African migrants. PMID:28582412

  15. Comparative Evaluation of Bivalent Malaria Rapid Diagnostic Tests versus Traditional Methods in Field with Special Reference to Heat Stability Testing in Central India

    PubMed Central

    Singh, Neeru; Bharti, Praveen K.; Singh, Mrigendra P.; Mishra, Sweta; Shukla, Man M.; Sharma, Ravendra K.; Singh, Rajesh K.

    2013-01-01

    Background Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs) showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability. Methodology/Principal Findings This study was undertaken in four forested districts of central India (July, 2011– March, 2012). All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9–98.8) and lowest sensitivity was 76% (95% CI; 71.7–79.6). For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9) and 20% (95% CI; 15.6–24.5) respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6–0.9). Conclusion This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely. PMID:23472135

  16. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    PubMed

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  17. Comparison of serum specific IgE with skin prick test in the diagnosis of allergy in Malaysia.

    PubMed

    Asha'ari, Z A; Suhaimi, Y; Yusof, R A; Rushdan, I; Maraina, C H C

    2011-08-01

    We compared a newer serum specific IgE (SSIgE) test with skin prick testing (SPT) in the diagnosis of allergy in Malaysia. Ninety newly diagnosed allergic patients were enrolled for both tests. Using SPT as a clinical gold standard, the sensitivity, specificity, positive, and negative predictive values (PPV, NPV) were calculated for SSIgE for each of the common allergens tested. The highest positive results for both SPT and SSIgE were for house dust mite and cat. Compared to SPT, SSIgE showed better sensitivity but poorer specificity, low PPV and good NPV in all the allergens tested. Significant positive correlation was seen between the diameter of wheal and flare of SPT and the SSIgE results.

  18. Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome

    PubMed Central

    Wang, Zhixue; Zou, Yuanyuan; Li, Wenying; Wang, Xueyan; Zhang, Min; Wang, Wenying

    2015-01-01

    Abstract This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests. Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal–Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance. The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P < 0.01). Besides, OCT manifestations were associated with CS at each spacial frequency including 1.5, 3, 6, 12, and 18 frequency (P < 0.01). And patients with abnormal manifestations of OCT showed lower CS at each spacial frequency than those without abnormal OCT manifestations. What's more the OCT manifestation 1 showed the greatest impact on CS at each spacial frequency. The results showed that abnormal OCT manifestations were correlated with CS in PIHS. OCT and CS tests might be valuable methods in observing fundus changes for PIHS patients. PMID:26554764

  19. A novel in chemico method to detect skin sensitizers in highly diluted reaction conditions.

    PubMed

    Yamamoto, Yusuke; Tahara, Haruna; Usami, Ryota; Kasahara, Toshihiko; Jimbo, Yoshihiro; Hioki, Takanori; Fujita, Masaharu

    2015-11-01

    The direct peptide reactivity assay (DPRA) is a simple and versatile alternative method for the evaluation of skin sensitization that involves the reaction of test chemicals with two peptides. However, this method requires concentrated solutions of test chemicals, and hydrophobic substances may not dissolve at the concentrations required. Furthermore, hydrophobic test chemicals may precipitate when added to the reaction solution. We previously established a high-sensitivity method, the amino acid derivative reactivity assay (ADRA). This method uses novel cysteine (NAC) and novel lysine derivatives (NAL), which were synthesized by introducing a naphthalene ring to the amine group of cysteine and lysine residues. In this study, we modified the ADRA method by reducing the concentration of the test chemicals 100-fold. We investigated the accuracy of skin sensitization predictions made using the modified method, which was designated the ADRA-dilutional method (ADRA-DM). The predictive accuracy of the ADRA-DM for skin sensitization was 90% for 82 test chemicals which were also evaluated via the ADRA, and the predictive accuracy in the ADRA-DM was higher than that in the ADRA and DPRA. Furthermore, no precipitation of test compounds was observed at the initiation of the ADRA-DM reaction. These results show that the ADRA-DM allowed the use of test chemicals at concentrations two orders of magnitude lower than that possible with the ADRA. In addition, ADRA-DM does not have the restrictions on test compound solubility that were a major problem with the DPRA. Therefore, the ADRA-DM is a versatile and useful method. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Improving the analysis of slug tests

    USGS Publications Warehouse

    McElwee, C.D.

    2002-01-01

    This paper examines several techniques that have the potential to improve the quality of slug test analysis. These techniques are applicable in the range from low hydraulic conductivities with overdamped responses to high hydraulic conductivities with nonlinear oscillatory responses. Four techniques for improving slug test analysis will be discussed: use of an extended capability nonlinear model, sensitivity analysis, correction for acceleration and velocity effects, and use of multiple slug tests. The four-parameter nonlinear slug test model used in this work is shown to allow accurate analysis of slug tests with widely differing character. The parameter ?? represents a correction to the water column length caused primarily by radius variations in the wellbore and is most useful in matching the oscillation frequency and amplitude. The water column velocity at slug initiation (V0) is an additional model parameter, which would ideally be zero but may not be due to the initiation mechanism. The remaining two model parameters are A (parameter for nonlinear effects) and K (hydraulic conductivity). Sensitivity analysis shows that in general ?? and V0 have the lowest sensitivity and K usually has the highest. However, for very high K values the sensitivity to A may surpass the sensitivity to K. Oscillatory slug tests involve higher accelerations and velocities of the water column; thus, the pressure transducer responses are affected by these factors and the model response must be corrected to allow maximum accuracy for the analysis. The performance of multiple slug tests will allow some statistical measure of the experimental accuracy and of the reliability of the resulting aquifer parameters. ?? 2002 Elsevier Science B.V. All rights reserved.

  1. Development of an artificial neural network model for risk assessment of skin sensitization using human cell line activation test, direct peptide reactivity assay, KeratinoSens™ and in silico structure alert parameter.

    PubMed

    Hirota, Morihiko; Ashikaga, Takao; Kouzuki, Hirokazu

    2018-04-01

    It is important to predict the potential of cosmetic ingredients to cause skin sensitization, and in accordance with the European Union cosmetic directive for the replacement of animal tests, several in vitro tests based on the adverse outcome pathway have been developed for hazard identification, such as the direct peptide reactivity assay, KeratinoSens™ and the human cell line activation test. Here, we describe the development of an artificial neural network (ANN) prediction model for skin sensitization risk assessment based on the integrated testing strategy concept, using direct peptide reactivity assay, KeratinoSens™, human cell line activation test and an in silico or structure alert parameter. We first investigated the relationship between published murine local lymph node assay EC3 values, which represent skin sensitization potency, and in vitro test results using a panel of about 134 chemicals for which all the required data were available. Predictions based on ANN analysis using combinations of parameters from all three in vitro tests showed a good correlation with local lymph node assay EC3 values. However, when the ANN model was applied to a testing set of 28 chemicals that had not been included in the training set, predicted EC3s were overestimated for some chemicals. Incorporation of an additional in silico or structure alert descriptor (obtained with TIMES-M or Toxtree software) in the ANN model improved the results. Our findings suggest that the ANN model based on the integrated testing strategy concept could be useful for evaluating the skin sensitization potential. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Screening for alcohol use disorders and at-risk drinking in the general population: psychometric performance of three questionnaires.

    PubMed

    Rumpf, Hans-Jürgen; Hapke, Ulfert; Meyer, Christian; John, Ulrich

    2002-01-01

    Most screening questionnaires are developed in clinical settings and there are few data on their performance in the general population. This study provides data on the area under the receiver-operating characteristic (ROC) curve, sensitivity, specificity, and internal consistency of the Alcohol Use Disorders Identification Test (AUDIT), the consumption questions of the AUDIT (AUDIT-C) and the Lübeck Alcohol Dependence and Abuse Screening Test (LAST) among current drinkers (n = 3551) of a general population sample in northern Germany. Alcohol dependence and misuse according to DSM-IV and at-risk drinking served as gold standards to assess sensitivity and specificity and were assessed with the Munich-Composite Diagnostic Interview (M-CIDI). AUDIT and LAST showed insufficient sensitivity for at-risk drinking and alcohol misuse using standard cut-off scores, but satisfactory detection rates for alcohol dependence. The AUDIT-C showed low specificity in all criterion groups with standard cut-off. Adjusted cut-points are recommended. Among a subsample of individuals with previous general hospital admission in the last year, all questionnaires showed higher internal consistency suggesting lower reliability in non-clinical samples. In logistic regression analyses, having had a hospital admission increased the sensitivity in detecting any criterion group of the LAST, and the number of recent general practice visits increased the sensitivity of the AUDIT in detecting alcohol misuse. Women showed lower scores and larger areas under the ROC curves. It is concluded that setting specific instruments (e.g. primary care or general population) or adjusted cut-offs should be used.

  3. Particle swarm optimization of the sensitivity of a cryogenic gravitational wave detector

    NASA Astrophysics Data System (ADS)

    Michimura, Yuta; Komori, Kentaro; Nishizawa, Atsushi; Takeda, Hiroki; Nagano, Koji; Enomoto, Yutaro; Hayama, Kazuhiro; Somiya, Kentaro; Ando, Masaki

    2018-06-01

    Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of shaping the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Therefore, careful tuning of multiple parameters is necessary in designing the sensitivity of cryogenic gravitational wave detectors. Here, we propose the use of particle swarm optimization to optimize the parameters of these detectors. We apply it for designing the sensitivity of the KAGRA detector, and show that binary neutron star inspiral range can be improved by 10%, just by retuning seven parameters of existing components. We also show that the sky localization of GW170817-like binaries can be further improved by a factor of 1.6 averaged across the sky. Our results show that particle swarm optimization is useful for designing future gravitational wave detectors with higher dimensionality in the parameter space.

  4. A comparison of experimental and theoretical results for leakage, pressure distribution, and rotordynamic coefficients for annular gas seals

    NASA Technical Reports Server (NTRS)

    Nicks, C. O.; Childs, D. W.

    1984-01-01

    The importance of seal behavior in rotordynamics is discussed and current annular seal theory is reviewed. A Nelson's analytical-computational method for determining rotordynamic coefficients for this type of compressible-flow seal is outlined. Various means for the experimental identification of the dynamic coefficients are given, and the method employed at the Texas A and M University (TAMU) test facility is explained. The TAMU test apparatus is described, and the test procedures are discussed. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and rotordynamic coefficients for a smooth and a honeycomb constant-clearance seal are presented and compared to theoretical results from Nelson's analysis. The results for both seals show little sensitivity to the running speed over the test range. Agreement between test results and theory for leakage through the seal is satisfactory. Test results for direct stiffness show a greater sensitivity to fluid pre-rotation than predicted. Results also indicate that the deliberately roughened surface of the honeycomb seal provides improved stability versus the smooth seal.

  5. Sensitivity to Morphosyntactic Information in 3-Year-Old Children With Typical Language Development: A Feasibility Study.

    PubMed

    Deevy, Patricia; Leonard, Laurence B; Marchman, Virginia A

    2017-03-01

    This study tested the feasibility of a method designed to assess children's sensitivity to tense/agreement information in fronted auxiliaries during online comprehension of questions (e.g., Are the nice little dogs running?). We expected that a group of children who were proficient in auxiliary use would show this sensitivity, indicating an awareness of the relation between the subject-verb sequence (e.g., dogs running) and preceding information (e.g., are). Failure to grasp this relation is proposed to play a role in the protracted inconsistency in auxiliary use in children with specific language impairment (SLI). Fifteen 3-year-old typically developing children who demonstrated proficiency in auxiliary use viewed pairs of pictures showing a single agent and multiple agents while hearing questions with or without an agreeing fronted auxiliary. Proportion looking to the target was measured. Children showed anticipatory looking on the basis of the number information contained in the auxiliary (is or are). The children tested in this study represent a group that frequently serves as a comparison for older children with SLI. Because the method successfully demonstrated their sensitivity to tense/agreement information in questions, future research that involves direct comparisons of these 2 groups is warranted.

  6. Validation of the shake test for detecting freeze damage to adsorbed vaccines.

    PubMed

    Kartoglu, Umit; Ozgüler, Nejat Kenan; Wolfson, Lara J; Kurzatkowski, Wiesław

    2010-08-01

    To determine the validity of the shake test for detecting freeze damage in aluminium-based, adsorbed, freeze-sensitive vaccines. A double-blind crossover design was used to compare the performance of the shake test conducted by trained health-care workers (HCWs) with that of phase contrast microscopy as a "gold standard". A total of 475 vials of 8 different types of World Health Organization prequalified freeze-sensitive vaccines from 10 different manufacturers were used. Vaccines were kept at 5 degrees C. Selected numbers of vials from each type were then exposed to -25 degrees C and -2 degrees C for 24-hour periods. There was complete concordance between HCWs and phase-contrast microscopy in identifying freeze-damaged vials and non-frozen samples. Non-frozen samples showed a fine-grain structure under phase contrast microscopy, but freeze-damaged samples showed large conglomerates of massed precipitates with amorphous, crystalline, solid and needle-like structures. Particles in the non-frozen samples measured from 1 microm (vaccines against diphtheria-tetanus-pertussis; Haemophilus influenzae type b; hepatitis B; diphtheria-tetanus-pertussis-hepatitis B) to 20 microm (diphtheria and tetanus vaccines, alone or in combination). By contrast, aggregates in the freeze-damaged samples measured up to 700 microm (diphtheria-tetanus-pertussis) and 350 microm on average. The shake test had 100% sensitivity, 100% specificity and 100% positive predictive value in this study, which confirms its validity for detecting freeze damage to aluminium-based freeze-sensitive vaccines.

  7. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    PubMed

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  8. Effects of prevalence on visual search and decision making in fracture detection

    NASA Astrophysics Data System (ADS)

    Ethell, Susan C.; Manning, David

    2001-06-01

    Research concerning disease prevalence has inferred that indices of observer performance become, in part, a function of predetermined prevalence. The cause of this modified performance and decision-making is not fully understood, although the alteration of the criterion level of the observer may be a feature. Novice radiography students were randomly assigned to one of three digitised test banks of 72 wrist images. Test bank A, B and C represented a fracture prevalence of 50%, 83% and 22% respectively. Half of the observers from each group were made aware of the prevalence of their respective test bank. Observers recorded their decisions on an operator rating scale. Results showed significant differences in overall Az between the 50% and 83% prevalence sets (p equals 0.04) and the 50% and 22% prevalence sets (p equals 0.005). Knowledge of the prevalence influenced both sensitivity and specificity values at the 83% prevalence level (p equals 0.03 and 0.02) but not at the lower levels. For test bank A sensitivity was 87%; specificity 53%; Az 0.80, test bank B sensitivity 81%; specificity 48%; Az 0.71 and test bank C sensitivity 85%; specificity 43%; Az 0.68. Analysis of the eye movement patterns of observers under conditions of varying prevalence is in progress.

  9. The relevance of basophil allergen sensitivity testing to distinguish between severe and mild peanut-allergic children.

    PubMed

    Homšak, Matjaž; Silar, Mira; Berce, Vojko; Tomazin, Maja; Skerbinjek-Kavalar, Maja; Celesnik, Nina; Košnik, Mitja; Korošec, Peter

    2013-01-01

    Peanut sensitization is common in children. However, it is difficult to assess which children will react mildly and which severely. This study evaluated the relevance of basophil allergen sensitivity testing to distinguish the severity of peanut allergy in children. Twenty-seven peanut-sensitized children with symptoms varying from mild symptoms to severe anaphylaxis underwent peanut CD63 dose-response curve analysis with the inclusion of basophil allergen sensitivity calculation (CD-sens) and peanut component immunoglobulin E (IgE) testing. Eleven children who had experienced anaphylaxis to peanuts showed a markedly higher peanut CD63 response at submaximal allergen concentrations and CD-sens (median 1,667 vs. 0.5; p < 0.0001) than 16 children who experienced a milder reaction. Furthermore, a negative or low CD-sens to peanuts unambiguously excluded anaphylactic peanut allergy. Children with anaphylaxis have higher levels of Ara h 1, 2, 3 and 9 IgE, but comparable levels of IgE to Ara h 8 and whole-peanut extract. The diagnostic specificity calculated with a receiver operating characteristic analysis reached 100% for CD-sens and 73% for Ara h 2. We demonstrated that severe peanut allergy is significantly associated with higher basophil allergen sensitivity. This cellular test should facilitate a more accurate diagnosis of peanut allergy. © 2013 S. Karger AG, Basel.

  10. Impact of test sensitivity and specificity on pig producer incentives to control Mycobacterium avium infections in finishing pigs.

    PubMed

    van Wagenberg, Coen P A; Backus, Gé B C; Wisselink, Henk J; van der Vorst, Jack G A J; Urlings, Bert A P

    2013-09-01

    In this paper we analyze the impact of the sensitivity and specificity of a Mycobacterium avium (Ma) test on pig producer incentives to control Ma in finishing pigs. A possible Ma control system which includes a serodiagnostic test and a penalty on finishing pigs in herds detected with Ma infection was modelled. Using a dynamic optimization model and a grid search of deliveries of herds from pig producers to slaughterhouse, optimal control measures for pig producers and optimal penalty values for deliveries with increased Ma risk were identified for different sensitivity and specificity values. Results showed that higher sensitivity and lower specificity induced use of more intense control measures and resulted in higher pig producer costs and lower Ma seroprevalence. The minimal penalty value needed to comply with a threshold for Ma seroprevalence in finishing pigs at slaughter was lower at higher sensitivity and lower specificity. With imperfect specificity a larger sample size decreased pig producer incentives to control Ma seroprevalence, because the higher number of false positives resulted in an increased probability of rejecting a batch of finishing pigs irrespective of whether the pig producer applied control measures. We conclude that test sensitivity and specificity must be considered in incentive system design to induce pig producers to control Ma in finishing pigs with minimum negative effects. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Prevalence of sensitization to the predatory mite Amblyseius cucumeris as a new occupational allergen in horticulture.

    PubMed

    Groenewoud, G C M; de Graaf in 't Veld, C; vVan Oorschot-van Nes, A J; de Jong, N W; Vermeulen, A M; van Toorenenbergen, A W; Burdorf, A; de Groot, H; Gerth van Wijk, R

    2002-07-01

    Protection against thrips, a common pest in bell pepper horticulture is effectively possible without pesticides by using the commercially available predatory mite Amblyzeius cucumeris (Ac). The prevalence of sensitization to Ac among exposed greenhouse employees and its clinical relevance was studied. Four hundred and seventytwo employees were asked to fill in a questionnaire and were tested on location. Next to RAST, skin prick tests (SPTs) were performed with common inhalant allergens, the storage mite Tyrophagus putrescentiae (Tp) which serves as a temporary food source during the cultivation process and Ac. Furthermore, nasal challenge tests with Ac were carried out in 23 sensitized employees. SPTs positive to Ac were found in 109 employees (23%). Work-related symptoms were reported by 76.1%. Sensitization to Tp was found in 62 employees of whom 48 were also sensitized to Ac. Immunoglobulin (Ig)E-mediated allergy to inhalant allergens appeared to be an important risk factor for sensitization to Ac. Employees with rhinitis symptoms showed a significantly higher response to all Ac doses during the nasal challenge test compared with employees without rhinitis symptoms. The predatory mite Ac is a new occupational allergen in horticulture which can cause an IgE-mediated allergy in exposed employees. It is biologically active on the mucous membranes of the nose and therefore clinically relevant for the development of work-related symptoms.

  12. Toward earlier detection of choroidal neovascularization secondary to age-related macular degeneration: multicenter evaluation of a preferential hyperacuity perimeter designed as a home device.

    PubMed

    Loewenstein, Anat; Ferencz, Joseph R; Lang, Yaron; Yeshurun, Itamar; Pollack, Ayala; Siegal, Ruth; Lifshitz, Tova; Karp, Joseph; Roth, Daniel; Bronner, Guri; Brown, Justin; Mansour, Sam; Friedman, Scott; Michels, Mark; Johnston, Richards; Rapp, Moshe; Havilio, Moshe; Rafaeli, Omer; Manor, Yair

    2010-01-01

    The primary purpose of this study was to evaluate the ability of a home device preferential hyperacuity perimeter to discriminate between patients with choroidal neovascularization (CNV) and intermediate age-related macular degeneration (AMD), and the secondary purpose was to investigate the dependence of sensitivity on lesion characteristics. All participants were tested with the home device in an unsupervised mode. The first part of this work was retrospective using tests performed by patients with intermediate AMD and newly diagnosed CNV. In the second part, the classifier was prospectively challenged with tests performed by patients with intermediate AMD and newly diagnosed CNV. The dependence of sensitivity on lesion characteristics was estimated with tests performed by patients with CNV of both parts. In 66 eyes with CNV and 65 eyes with intermediate AMD, both sensitivity and specificity were 0.85. In the retrospective part (34 CNV and 43 intermediate AMD), sensitivity and specificity were 0.85 +/- 0.12 (95% confidence interval) and 0.84 +/- 0.11 (95% confidence interval), respectively. In the prospective part (32 CNV and 22 intermediate AMD), sensitivity and specificity were 0.84 +/- 0.13 (95% confidence interval) and 0.86 +/- 0.14 (95% confidence interval), respectively. Chi-square analysis showed no dependence of sensitivity on type (P = 0.44), location (P = 0.243), or size (P = 0.73) of the CNV lesions. A home device preferential hyperacuity perimeter has good sensitivity and specificity in discriminating between patients with newly diagnosed CNV and intermediate AMD. Sensitivity is not dependent on lesion characteristics.

  13. 49 CFR 227.5 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this part. Exchange rate means the change in sound level, in decibels, which would require halving or... audiometric testing, showing the thresholds of hearing sensitivity measured at discrete frequencies, as well... discrete frequencies. Audiometry can also be referred to as audiometric testing. Baseline audiogram means...

  14. [Comparison of Dengue viral nonstructural protein 1 antigen testing kits].

    PubMed

    Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F

    2018-02-06

    Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.

  15. Using Pressure- and Temperature-Sensitive Paint for Global Surface Pressure and Temperature Measurements on the Aft-Body of a Capsule Reentry Vehicle

    NASA Technical Reports Server (NTRS)

    Watkins, A. Neal; Buck, Gregory M.; Leighty, Bradley D.; Lipford, William E.; Oglesby, Donald M.

    2008-01-01

    Pressure Sensitive Paint (PSP) and Temperature Sensitive Paint (TSP) were used to visualize and quantify the surface interactions of reaction control system (RCS) jets on the aft body of capsule reentry vehicle shapes. The first model tested was an Apollo-like configuration and was used to focus primarily on the effects of the forward facing roll and yaw jets. The second model tested was an early Orion Crew Module configuration blowing only out of its forward-most yaw jet, which was expected to have the most intense aerodynamic heating augmentation on the model surface. This paper will present the results from the experiments, which show that with proper system design, both PSP and TSP are effective tools for studying these types of interaction in hypersonic testing environments.

  16. The sensitivity, specificity and efficiency values of some serological tests used in the diagnosis of paracoccidioidomycosis.

    PubMed

    Del Negro, G M; Garcia, N M; Rodrigues, E G; Cano, M I; de Aguiar, M S; Lírio, V de S; Lacaz, C da S

    1991-01-01

    This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e., a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO. The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

  17. Underwater audiogram of a tucuxi (Sotalia fluviatilis guianensis).

    PubMed

    Sauerland, M; Dehnhardt, G

    1998-02-01

    Using a go/no go response paradigm, a tucuxi (Sotalia fluviatilis guianensis) was trained to respond to pure-tone signals for an underwater hearing test. Auditory thresholds were obtained from 4 to 135 kHz. The audiogram curve shows that this Sotalia had an upper limit of hearing at 135 kHz; from 125 to 135 kHz sensitivity decreased by 475 dB/oct. This coincides with results from electrophysiological threshold measurements. The range of best hearing (defined as 10 dB from maximum sensitivity) was between 64 and 105 kHz. This range appears to be narrower and more restricted to higher frequencies in Sotalia fluviatilis guianensis than in other odontocete species that had been tested before. Peak frequencies of echolocation pulses reported from free-ranging Sotalia correspond with the range of most sensitive hearing of this test subject.

  18. Sensitivity and specificity of different methods for cystic fibrosis-related diabetes screening: is the oral glucose tolerance test still the standard?

    PubMed

    Mainguy, Catherine; Bellon, Gabriel; Delaup, Véronique; Ginoux, Tiphanie; Kassai-Koupai, Behrouz; Mazur, Stéphane; Rabilloud, Muriel; Remontet, Laurent; Reix, Philippe

    2017-01-01

    Cystic fibrosis-related diabetes (CFRD) is a late cystic fibrosis (CF)-associated comorbidity whose prevalence is increasing sharply lifelong. Guidelines for glucose metabolism (GM) monitoring rely on the oral glucose tolerance test (OGTT). However, this test is neither sensitive nor specific. The aim of this study was to compare sensitivity and specificity of different methods for GM monitoring in children and adolescents with CF. Continuous glucose monitoring system (CGMS), used as the reference method, was compared with the OGTT, intravenous glucose tolerance test (IGTT), homeostasis model assessment index of insulin resistance (HOMA-IR), homeostasis model assessment index of β-cell function (HOMA-%B) and glycated haemoglobin A1C. Patients were classified into three groups according to CGMS: normal glucose tolerance (NGT), impaired glucose tolerance (IGT) and diabetes mellitus (DM). Twenty-nine patients (median age: 13.1 years) were recruited. According to CGMS, 11 had DM, 12 IGT and six NGT, whereas OGTT identified three patients with DM and five with IGT. While 13 of 27 had insulin deficiency according to IGTT, there was 19 of 28 according to HOMA-%B. According to HOMA-IR, 12 of 28 had insulin resistance. HOMA-%B was the most sensitive method for CFRD screening [sensitivity 91% (95% CI), specificity 47% (95% CI) and negative predictive value 89% (95% CI)]. OGTT showed the weak capacity to diagnose DM in CF and should no longer be considered as the reference method for CFRD screening in patients with CF. In our study, HOMA-%B showed promising metrics for CFRD screening. Finally, CGMS revealed that pathological glucose excursions were frequent even early in life.

  19. Diagnostic value of serum Golgi protein 73 for HBV-related primary hepatic carcinoma

    PubMed Central

    Gao, Guosheng; Dong, Feibo; Xu, Xiaozhen; Hu, Airong; Hu, Yaoren

    2015-01-01

    Background: Alpha-fetoprotein (AFP) levels are routinely used for diagnosis and monitoring of hepatic diseases, but it has a limited value. Golgi protein 73 (GP73) has been suggested as a new marker for hepatic diseases. Objective: To explore the clinical value of serum GP73 in different diseases associated with hepatitis B virus (HBV) infection. Method: Between January 2010 and August 2014, serum samples from 88 patients with chronic hepatitis B (CHB), 78 patients with HBV-related liver cirrhosis (LC), and 194 patients with HBV-related primary hepatic cancer (PHC) were collected. Serum samples from 30 healthy volunteers were used as controls. ELISA and microparticle enzyme immunoassay were used to measure serum GP73 and AFP levels. Receiver operating characteristic (ROC) curves were used to analyze the diagnostic value of serum GP73 and AFP for PHC. Results: For the diagnosis of PHC, GP73 showed a sensitivity of 65.5% and specificity of 66.3%, while AFP levels showed sensitivity of 64.4% and specificity of 76.5%. Serial testing (both tests are positive) could increase the specificity (sensitivity of 45.9% and specificity of 85.5%) while parallel testing (any single positive test result) could increase the sensitivity (sensitivity of 84.0% and specificity of 57.2%). Serum GP73 and AFP levels were significantly different between Child-Pugh grades (P<0.001 for GP73 and P=0.044 for AFP). Significant differences in serum GP73 and AFP were found between TNM stages (all P<0.001). Conclusion: Serum GP73 had limited diagnostic value for HBV-related PHC. The combined use of serum GP73 and AFP levels improved the diagnostic efficacy. PMID:26617863

  20.  The product of triglycerides and glucose as biomarker for screening simple steatosis and NASH in asymptomatic women.

    PubMed

    Simental-Mendía, Luis E; Simental-Mendía, Esteban; Rodríguez-Hernández, Heriberto; Rodríguez-Morán, Martha; Guerrero-Romero, Fernando

    2016-01-01

     Introduction and aim. Given that early identification of non-alcoholic fatty liver disease (NAFLD) is an important issue for primary prevention of hepatic disease, the objectives of this study were to evaluate the efficacy of the product of triglyceride and glucose levels (TyG) for screening simple steatosis and non-alcoholic steatohepatitis (NASH) in asymptomatic women, and to compare its efficacy vs. other biomarkers for recognizing NAFLD. Asymptomatic women aged 20 to 65 years were enrolled into a cross-sectional study. The optimal values of TyG, for screening simple steatosis and NASH were established on a Receiver Operating Characteristic scatter plot; the sensitivity, specificity, and likelihood ratios of TyG index were estimated versus liver biopsy. According sensitivity and specificity, the efficacy of TyG was compared versus the well-known clinical biomarkers for recognizing NAFLD. A total of 50 asymptomatic women were enrolled. The best cutoff point of TyG for screening simple steatosis was 4.58 (sensitivity 0.94, specificity 0.69); in addition, the best cutoff point of TyG index for screening NASH was 4.59 (sensitivity 0.87, specificity 0.69). The positive and negative likelihood ratios were 3.03 and 0.08 for simple steatosis, and 2.80 and 0.18 for NASH. As compared versus SteatoTest, NashTest, Fatty liver index, and Algorithm, the TyG showed to be the best test for screening. TyG has high sensitivity and low negative likelihood ratio; as compared with other clinical biomarkers, the TyG showed to be the best test for screening simple steatosis and NASH.

  1. Comparative Evaluation of Tubex TF (Inhibition Magnetic Binding Immunoassay) for Typhoid Fever in Endemic Area.

    PubMed

    Khanna, Ashish; Khanna, Menka; Gill, Karamjit Singh

    2015-11-01

    Typhoid fever remains a significant health problem in endemic countries like India. Various serological tests for the diagnosis of typhoid fever are available commercially. We assessed the usefulness of rapid test based on magnetic particle separation to detect Immunoglobulin against Salmonella typhi O9 lipopolysaccharide. Aim of this study was to compare the sensitivity and specificity of widal test, typhidot and tubex TF test for the diagnosis of typhoid fever in an endemic country like India. Serum samples collected from 50 patients of typhoid fever, 50 patients of non typhoid fever and 100 normal healthy individuals residing in Amritsar were subjected to widal test, typhidot test and tubex TF test as per manufacturer's instructions. Data collected was assessed to find sensitivity and specificity of these tests in an endemic area. Significant widal test results were found positive in 68% of patients of typhoid fever and only 4% of non typhoid fever patients. Typhidot (IgM or IgG) was positive in 72% of typhoid fever patients and 10% and 6% in non typhoid fever and normal healthy individuals respectively. Tubex TF showed higher sensitivity of 76% and specificity of 96-99% which was higher than typhidot and comparable to widal test. This was the first evaluation of rapid tubex TF test in northern India. In countries which can afford high cost of test, tubex TF should be recommended for the diagnosis in acute stage of the disease in clinical setting. However, there is urgent need for a highly specific and sensitive test for the diagnosis of typhoid fever in clinical settings in endemic areas.

  2. Phytotoxicity of floodplain soils contaminated with trace metals along the clark fork river, Grant-Kohrs Ranch National Historic Site, Deer Lodge, Montana, United States

    USGS Publications Warehouse

    Rader, B.R.; Nimmo, D.W.R.; Chapman, P.L.

    1997-01-01

    Concentrations of metals in sediments and soils deposited along the floodplain of the Clark Fork River, within the Grant-Kohrs Ranch National Historic Site, Deer Lodge, Montana, USA, have exceeded maximum background concentrations in the United States for most metals tested. As a result of mining and smelting activities, portions of the Deer Lodge Valley, including the Grant-Kohrs Ranch, have received National Priority List Designation under the Comprehensive Environmental Response, Compensation and Liability Act. Using a series of plant germination tests, pH measurements, and metal analyses, this study investigated the toxicity of soils from floodplain 'slicken' areas, bare spots devoid of vegetation, along the Clark Fork River. The slicken soils collected from the Grant-Kohrs Ranch were toxic to all four plant species tested. The most sensitive endpoint in the germination tests was root length and the least sensitive was emergence. Considering emergence, the most sensitive species was the resident grass species Agrostis gigantea. The sensitivities were reversed when root lengths were examined, with Echinochloa crusgalli showing the greatest sensitivity. Both elevated concentrations of metals and low pH were necessary to produce an acutely phytotoxic response in laboratory seed germination tests using slicken soils. Moreover, pH values on the Grant-Kohrs Ranch appear to be a better predictor of acutely phytotoxic conditions than total metal levels.

  3. Test characteristics of the SD FK80 Plasmodium falciparum/Plasmodium vivax malaria rapid diagnostic test in a non-endemic setting

    PubMed Central

    2009-01-01

    Background The SD FK80 P.f/P.v Malaria Antigen Rapid Test (Standard Diagnostics, Korea) (FK80) is a three-band malaria rapid diagnostic test detecting Plasmodium falciparum histidine-rich protein-2 (HRP-2) and Plasmodium vivax-specific lactate dehydrogenase (Pv-pLDH). The present study assessed its performance in a non-endemic setting. Methods Stored blood samples (n = 416) from international travellers suspected of malaria were used, with microscopy corrected by PCR as the reference method. Samples infected by Plasmodium falciparum (n = 178), Plasmodium vivax (n = 99), Plasmodium ovale (n = 75) and Plasmodium malariae (n = 24) were included, as well as 40 malaria negative samples. Results Overall sensitivities for the diagnosis of P. falciparum and P. vivax were 91.6% (95% confidence interval (CI): 86.2% - 95.0%) and 75.8% (65.9% - 83.6%). For P. falciparum, sensitivity at parasite densities ≥ 100/μl was 94.6% (88.8% - 97.6%); for P. vivax, sensitivity at parasite densities ≥ 500/μl was 86.8% (75.4% - 93.4%). Four P. falciparum samples showed a Pv-pLDH line, three of them had parasite densities exceeding 50.000/μl. Two P. vivax samples, one P. ovale and one P. malariae sample showed a HRP-2 line. For the HRP-2 and Pv-pLDH lines, respectively 81.4% (136/167) and 55.8% (43/77) of the true positive results were read as medium or strong line intensities. The FK80 showed good reproducibility and reliability for test results and line intensities (kappa values for both exceeding 0.80). Conclusion The FK80 test performed satisfactorily in diagnosing P. falciparum and P. vivax infections in a non-endemic setting. PMID:19930609

  4. High prevalence of sensitization to aeroallergens in children 4 yrs of age or younger with symptoms of allergic disease.

    PubMed

    Baatenburg de Jong, Adriana; Dikkeschei, Lambert D; Brand, Paul L P

    2009-12-01

    The assumption that sensitization to aeroallergens is rare in preschool children is based on population studies in which most subjects have little or no symptoms of atopic disease. We assessed the prevalence of atopic sensitization in children 0 to 4 yr of age presenting with symptoms of allergic disease by reviewing results of all specific immunoglobulin (IgE) tests performed in our hospital laboratory in children 4 yr of age or younger between 1985 and 2003. Tests were ordered by general practitioners or hospital-based pediatricians in children presenting with symptoms of allergic disease. Specific IgE tests to a panel of common food and inhalant allergens were performed in 2946 children; a specific IgE concentration >0.35 kU/l was considered positive. Overall, 505 (17%) tests were positive to aeroallergens: 346 (12%) for house dust mite, 257 (9%) for dog dander, 240 (8%) for cat dander, and 197 (7%) for grass pollen. Positive tests were more common in boys (19.2%) than in girls (14.2%, p < 0.01), irrespective of age. Although sensitization to food allergens was more common in 0-<3 yr olds, aeroallergen and food allergen showed comparable prevalence rates in 3-<5 yr olds. Sensitization to aeroallergens is common in preschool children with symptoms of allergic disease, and more common in boys than in girls. Screening tests for allergy in infants and toddlers should include inhalant allergens.

  5. Combined in vivo and in vitro approach for the characterization of penicillin-specific polyclonal lymphocyte reactivity: tolerance tests with safe penicillins instead of challenge with culprit drugs.

    PubMed

    Sachs, B; Al Masaoudi, T; Merk, H F; Erdmann, S

    2004-10-01

    Amino-penicillins are a major cause of delayed-type reactions to penicillins. The aim of this study was to establish a diagnostic approach for the characterization of the individual penicillin-specific polyclonal lymphocyte reactivity in order to detect side chain-specific sensitization to amino-penicillins. Patients can then be advised to undergo a tolerance test with safe penicillins instead of provocation with culprit penicillins for confirmation of penicillin allergy. We investigated penicillin-specific polyclonal lymphocyte reactivity in nine patients with delayed-type reactions to amino-penicillins by a combined in vivo (patch, prick and intracutaneous tests with delayed readings) and in vitro (lymphocyte transformation test, LTT) approach. A combination of LTT and skin tests improved the sensitivity for the characterization of penicillin-specific polyclonal lymphocyte reactivity and allowed the detection of three different patterns of lymphocyte reactivity. Four patients showed a side chain-specific sensitization to amino-penicillins in vivo and in vitro and were advised to undergo tolerance tests with safe penicillins. Two patients agreed and were exposed to parenteral benzyl-penicillin and oral phenoxymethyl-penicillin which they tolerated without complications. These data suggest that a combined in vivo and in vitro approach is helpful for the detection of side chain-specific sensitization to amino-penicillins. Patients with such sensitization are very likely to tolerate safe penicillins, thereby expanding their therapeutic options when antibiotic treatment is required.

  6. Test battery with the human cell line activation test, direct peptide reactivity assay and DEREK based on a 139 chemical data set for predicting skin sensitizing potential and potency of chemicals.

    PubMed

    Takenouchi, Osamu; Fukui, Shiho; Okamoto, Kenji; Kurotani, Satoru; Imai, Noriyasu; Fujishiro, Miyuki; Kyotani, Daiki; Kato, Yoshinao; Kasahara, Toshihiko; Fujita, Masaharu; Toyoda, Akemi; Sekiya, Daisuke; Watanabe, Shinichi; Seto, Hirokazu; Hirota, Morihiko; Ashikaga, Takao; Miyazawa, Masaaki

    2015-11-01

    To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Discordance between Aeroallergen Specific Serum IgE and Skin Testing in Children < 4 years of age

    PubMed Central

    de Vos, Gabriele; Nazari, Ramin; Ferastraoaru, Denisa; Parikh, Purvi; Geliebter, Rebecca; Pichardo, Yikania; Wiznia, Andrew; Rosenstreich, David

    2015-01-01

    Background Atopic sensitization to aeroallergens in early life has been shown to be a strong risk factor for developing persisting asthma in young children with recurrent wheeze. Objective The aim of this study was to assess the yield of skin prick test (SPT) compared to allergen specific serum IgE testing (sIgE) at identifying aeroallergen sensitization in atopic children < 4 years of age. Methods Concordance between SPT (Greer Laboratories, ComforTen™) and allergen specific sIgE (Immulite 2000™) for 7 common aeroallergens was analyzed in forty atopic inner-city children, 18–48 months of age (mean 36 +/− 9 months) with recurrent wheezing, family history of asthma and/or eczema. Results In 80% of children one or more allergen sensitizations would have been missed if only SPT had been performed, and in 38% of children one or more sensitizations would have been missed if only serum IgE testing had been performed. Agreement and between SPT and sIgE test was fair for most allergens (kappa between −0.04 and 0.50), as was correlation between sIgE levels and SPT grade (rho between 0.21 and 0.55). Children with high total sIgE (≥300 kU/l) were more likely to have sIgE positive tests with negative corresponding skin test (p=0.025). Conclusions Our study showed significant discordance between allergen specific SPT and sIgE testing results for common aeroallergens, suggesting that both SPT and sIgE testing should be done when diagnosing allergic sensitization in young children at high risk of asthma. PMID:23706713

  8. Skin sensitization potency of isoeugenol and its dimers evaluated by a non-radioisotopic modification of the local lymph node assay and guinea pig maximization test.

    PubMed

    Takeyoshi, Masahiro; Iida, Kenji; Suzuki, Keiko; Yamazaki, Shunsuke

    2008-05-01

    Allergic contact dermatitis is the serious unwanted effect arising from the use of consumer products such as cosmetics. Isoeugenol is a fragrance chemical with spicy, carnation-like scent, is used in many kinds of cosmetics and is a well-known moderate human sensitizer. It was previously reported that the dimerization of eugenol yielded two types of dimer possessing different sensitization potencies. This study reports the differences in skin sensitization potencies for isoeugenol and two types of dimer, beta-O-4-dilignol and dehydrodiisoeugenol (DIEG), as evaluated by the non-radioisotopic local lymph node assay (non-RI LLNA) and guinea pig maximization test. In the guinea pig maximization test, isoeugenol, beta-O-4-dilignol and DIEG were classified as extreme, weak and moderate sensitizers, respectively. As for the results of non-RI LLNA, the EC3 for isoeugenol, beta-O-4-dilignol and DIEG were calculated as 12.7%, >30% and 9.4%, respectively. The two types of isoeugenol dimer showed different sensitizing activities similar to the case for eugenol dimers. A reduction of sensitization potency achieved by dimerization may lead to developing safer cosmetic ingredients. Isoeugenol dimers are not currently used for fragrance chemicals. However, the dimerization of isoeugenol may yield a promising candidate as a cosmetic ingredient with low sensitization risk. The data may also provide useful information for the structure-activity relationship (SAR) in skin sensitization. Copyright (c) 2007 John Wiley & Sons, Ltd.

  9. Negativization rates of IgE radioimmunoassay and basophil activation test in immediate reactions to penicillins.

    PubMed

    Fernández, T D; Torres, M J; Blanca-López, N; Rodríguez-Bada, J L; Gomez, E; Canto, G; Mayorga, C; Blanca, M

    2009-02-01

    Skin test sensitivity in patients with immediate allergy to penicillins tends to decrease over time, but no information is available concerning in vitro tests. We analysed the negativization rates of two in vitro methods that determine specific immunoglobulin E (IgE) antibodies, the basophil activation test using flow cytometry (BAT) and the radioallergosorbent test (RAST), in immediate allergic reactions to penicillins. Forty-one patients with immediate allergic reactions to amoxicillin were followed up over a 4-year period. BAT and RAST were performed at 6-month intervals. Patients were randomized into groups: Group I, skin tests carried out at regular intervals; Group II, skin tests made only at the beginning of the study. Differences were observed between RAST and BAT (P < 0.01), the latter showing earlier negativization. Considering different haptens, significant differences for the rate of negativization were only found for amoxicillin (P < 0.05). Comparisons between Groups I (n = 10) and II (n = 31) showed a tendency to become negative later in Group I with RAST. Levels of specific IgE antibodies tended to decrease over time in patients with immediate allergic reactions to amoxicillin. Conversion to negative took longer for the RAST assay, although the differences were only detected with the amoxicillin hapten. Skin testing influenced the rate of negativization of the RAST assay, contributing to maintenance of in vitro sensitivity. Because of the loss of sensitivity over time, the determination of specific IgE antibodies to penicillins in patients with immediate allergic reactions must be done as soon as possible after the reaction.

  10. A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context

    PubMed Central

    Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio

    2016-01-01

    The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266

  11. Evaluation of the rapid diagnostic test CareStart pLDH Malaria (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a reference setting.

    PubMed

    Heutmekers, Marloes; Gillet, Philippe; Maltha, Jessica; Scheirlinck, Annelies; Cnops, Lieselotte; Bottieau, Emmanuel; Van Esbroeck, Marjan; Jacobs, Jan

    2012-06-18

    The present study evaluated CareStart pLDH Malaria, a three-band rapid diagnostic test detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH) in a reference setting. CareStart pLDH was retrospectively and prospectively assessed with a panel of stored (n=498) and fresh (n=77) blood samples obtained in international travelers suspected of malaria. Both panels comprised all four Plasmodium species; the retrospective panel comprised also Plasmodium negative samples. The reference method was microscopy corrected by PCR. The prospective panel was run side-to-side with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). In the retrospective evaluation, overall sensitivity for P. falciparum samples (n=247) was 94.7%, reaching 98.7% for parasite densities>1,000/μl. Most false negative results occurred among samples with pure gametocytaemia (2/12, 16.7%) and at parasite densities ≤ 100/μl (7/12, 58.3%). None of the Plasmodium negative samples (n=96) showed visible test lines. Sensitivities for Plasmodium vivax (n=70), Plasmodium ovale (n=69) and Plasmodium malariae (n=16) were 74.3%, 31.9% and 25.0% respectively. Wrong species identification occurred in 10 (2.5%) samples and was mainly due to P. vivax samples reacting with the Pf-pLDH test line. Overall, Pf-pLDH test lines showed higher line intensities compared to the pan-pLDH lines (67.9% and 23.0% medium and strong line intensities for P. falciparum). In the prospective panel (77 Plasmodium-positive samples), CareStart pLDH showed higher sensitivities for P. falciparum compared to OptiMAL (p=0.008), lower sensitivities for P. falciparum as compare to SDFK60 (although not reaching statistical significance, p=0.08) and higher sensitivities for P. ovale compared to both OptiMAL (p=0.03) and SDFK60 (p=0.01). Inter-observer and test reproducibility were good to excellent. CareStart pLDH performed excellent for the detection of P. falciparum, well for P. vivax, but poor for P. ovale and P. malariae.

  12. Evaluation of an Automated Reader and Color Interpretation-Based Immunoassays for Multiplexed Drug-of-Abuse Testing in Urine.

    PubMed

    Kim, Seon Young; Kim, Hyunjin; Park, Yeongchun; Lim, Jinsook; Kim, Jimyung; Koo, Sun Hoe; Kwon, Gye Cheol

    2017-06-01

    On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. [Comparison of conventional and non-conventional serological tests for the diagnosis of imported Chagas disease in Spain].

    PubMed

    Flores-Chávez, María; Cruz, Israel; Rodríguez, Mercedes; Nieto, Javier; Franco, Elena; Gárate, Teresa; Cañavate, Carmen

    2010-05-01

    Trypanosoma cruzi infection is a major imported parasitic disease in Spain, because of the increase of immigrants from endemic areas. Since the laboratory diagnosis during the chronic phase is based on detection of anti-T. cruzi IgG antibodies, our aims were to compare 10 tests for determining anti-T. cruzi antibodies, to assess their cross-reactivity with related diseases, and to evaluate the rk39-ELISA and IFAT-Leishmania tests as tools for the differential diagnosis of leishmaniasis due to Leishmania infantum. A total of 223 sera were tested: 40 had been previously characterized by Qpanel, and 183 were obtained from the serum library of the Parasitology Department, Centro Nacional de Microbiología (66 chagasic, 97 healthy, 30 visceral leishmaniasis, and 30 malaria). Samples were examined using in-house IFAT and ELISA, 5 commercial ELISAs (Certest/Abbot Laboratories/BiosChile; Ortho Clinical Diagnostics; BLK Diagnostic; bioMérieux; and Biokit), particle gel agglutination (ID-PaGIA), and two immunochromatographic assays (Operon and CTK Biotech). The last 4 tests are based in recombinant antigens (non-conventional tests). The IFAT and ELISAs showed a sensitivity of 97% to 100%. The immunochromatographic tests had somewhat lower sensitivity (92%-96%). All non-conventional tests presented a smaller number of cross-reactions. Leishmania-Rk39-ELISA did not show cross-reactivity with chagasic sera. In general, our results confirm the data obtained by other authors. The sensitivity of ELISA is higher than other tests; therefore, these techniques would be the most appropriate for screening of T. cruzi infection. A suitable approach is the combination of a test using total antigen with another based on either recombinant antigens or synthetic peptides. (c) 2009 Elsevier España, S.L. All rights reserved.

  14. Vestibular (dys)function in children with sensorineural hearing loss: a systematic review.

    PubMed

    Verbecque, Evi; Marijnissen, Tessa; De Belder, Niels; Van Rompaey, Vincent; Boudewyns, An; Van de Heyning, Paul; Vereeck, Luc; Hallemans, Ann

    2017-06-01

    The objective of this study is to provide an overview of the prevalence of vestibular dysfunction in children with SNHL classified according to the applied test and its corresponding sensitivity and specificity. Data were gathered using a systematic search query including reference screening. Pubmed, Web of Science and Embase were searched. Strategy and reporting of this review was based on the Meta-analysis of Observational Studies in Epidemiology (MOOSE) guidelines. Methodological quality was assessed with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. All studies, regardless the applied vestibular test, showed that vestibular function differs significantly between children with hearing loss and normal hearing (p < 0.05). Compared with caloric testing, the sensitivity of the Rotational Chair Test (RCT) varies between 61 and 80% and specificity between 21 and 80%, whereas this was, respectively, 71-100% and 30-100% for collic Vestibular Evoked Myogenic Potentials (cVEMP). Compared with RCT, the sensitivity was 88-100% and the specificity was 69-100% for the Dynamic Visual Acuity test, respectively, 67-100% and 71-100% for the (video) Head Impulse Test and 83% and 86% for the ocular VEMP. Currently, due to methodological shortcoming, evidence on sensitivity and specificity of vestibular tests is unknown to moderate. Future research should focus on adequate sample sizes (subgroups >30).

  15. Triton Hodge Test: Improved Protocol for Modified Hodge Test for Enhanced Detection of NDM and Other Carbapenemase Producers

    PubMed Central

    Pasteran, Fernando; Gonzalez, Lisandro J.; Albornoz, Ezequiel; Bahr, Guillermo; Vila, Alejandro J.

    2015-01-01

    Accurate detection of carbapenemase-producing Gram-negative bacilli is of utmost importance for the control of nosocomial spread and the initiation of appropriate antimicrobial therapy. The modified Hodge test (MHT), a carbapenem inactivation assay, has shown poor sensitivity in detecting the worldwide spread of New Delhi metallo-β-lactamase (NDM). Recent studies demonstrated that NDM is a lipoprotein anchored to the outer membrane in Gram-negative bacteria, unlike all other known carbapenemases. Here we report that membrane anchoring of β-lactamases precludes detection of carbapenemase activity by the MHT. We also show that this limitation can be overcome by the addition of Triton X-100 during the test, which allows detection of NDM. We propose an improved version of the assay, called the Triton Hodge test (THT), which allows detection of membrane-bound carbapenemases with the addition of this nonionic surfactant. This test was challenged with a panel of 185 clinical isolates (145 carrying known carbapenemase-encoding genes and 40 carbapenemase nonproducers). The THT displayed test sensitivity of >90% against NDM-producing clinical isolates, while improving performance against other carbapenemases. Ertapenem provided the highest sensitivity (97 to 100%, depending on the type of carbapenemase), followed by meropenem (92.5 to 100%). Test specificity was not affected by the addition of Triton (87.5% and 92.5% with ertapenem and meropenem, respectively). This simple inexpensive test confers a large improvement to the sensitivity of the MHT for the detection of NDM and other carbapenemases. PMID:26719442

  16. MPT64 antigen detection test improves routine diagnosis of extrapulmonary tuberculosis in a low-resource setting: A study from the tertiary care hospital in Zanzibar.

    PubMed

    Jørstad, Melissa Davidsen; Marijani, Msafiri; Dyrhol-Riise, Anne Ma; Sviland, Lisbet; Mustafa, Tehmina

    2018-01-01

    Extrapulmonary tuberculosis (EPTB) is a diagnostic challenge. An immunochemistry-based MPT64 antigen detection test (MPT64 test) has reported higher sensitivity in the diagnosis of EPTB compared with conventional methods. The objective of this study was to implement and evaluate the MPT64 test in routine diagnostics in a low-resource setting. Patients with presumptive EPTB were prospectively enrolled at Mnazi Mmoja Hospital, Zanzibar, and followed to the end of treatment. Specimens collected were subjected to routine diagnostics, GeneXpert® MTB/RIF assay and the MPT64 test. The performance of the MPT64 test was assessed using a composite reference standard, defining the patients as tuberculosis (TB) cases or non-TB cases. Patients (n = 132) were classified as confirmed TB (n = 12), probable TB (n = 34), possible TB (n = 18), non-TB (n = 62) and uncategorized (n = 6) cases. Overall, in comparison to the composite reference standard for diagnosis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the MPT64 test was 69%, 95%, 94%, 75% and 82%, respectively. The MPT64 test performance was best in TB lymphadenitis cases (n = 67, sensitivity 79%, specificity 97%) and in paediatric TB (n = 41, sensitivity 100%, specificity 96%). We show that the MPT64 test can be implemented in routine diagnostics in a low-resource setting and improves the diagnosis of EPTB, especially in TB lymphadenitis and in children.

  17. Interpreting ambiguous 'trace' results in Schistosoma mansoni CCA Tests: Estimating sensitivity and specificity of ambiguous results with no gold standard.

    PubMed

    Clements, Michelle N; Donnelly, Christl A; Fenwick, Alan; Kabatereine, Narcis B; Knowles, Sarah C L; Meité, Aboulaye; N'Goran, Eliézer K; Nalule, Yolisa; Nogaro, Sarah; Phillips, Anna E; Tukahebwa, Edridah Muheki; Fleming, Fiona M

    2017-12-01

    The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous 'trace' result between 'positive' and 'negative', and much debate has focused on interpretation of traces results. We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d'Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence.

  18. Interpreting ambiguous ‘trace’ results in Schistosoma mansoni CCA Tests: Estimating sensitivity and specificity of ambiguous results with no gold standard

    PubMed Central

    Donnelly, Christl A.; Fenwick, Alan; Kabatereine, Narcis B.; Knowles, Sarah C. L.; Meité, Aboulaye; N'Goran, Eliézer K.; Nalule, Yolisa; Nogaro, Sarah; Phillips, Anna E.; Tukahebwa, Edridah Muheki; Fleming, Fiona M.

    2017-01-01

    Background The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous ‘trace’ result between ‘positive’ and ‘negative’, and much debate has focused on interpretation of traces results. Methodology/Principle findings We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d’Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. Conclusions Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence. PMID:29220354

  19. Transpalpebral electrotherapy for dry age-related macular degeneration (AMD): an exploratory trial.

    PubMed

    Anastassiou, Gerasimos; Schneegans, Anna-Lena; Selbach, Michael; Kremmer, Stephan

    2013-01-01

    To evaluate the effect of transpalpebral electrotherapy on patients with dry age-related macular degeneration (AMD). 22 patients were randomized in two groups to either receive therapy (n = 12) or placebo (n = 10). There was no statistically significant difference for age and initial visual acuity (VA) between the two groups (p = 0.6; ANOVA). Treatment was performed on 5 consecutive days. On each day two sessions were applied. Every session included 8 spots (40 sec/spot) around the eye globe. The current applied (changing frequency 5-80 Hz) varied individually between 150 and 220 μA. Patients were examined before treatment, at the end of the 5-day treatment period, after 4 weeks and at 6 months. Examinations included a standardized VA testing, using ETDRS letters, contrast sensitivity, macular sensitivity and fixation stability using microperimetry and measurements with SD-OCT. At the end of week 1, mean VA improved markedly (p = 0.001; T test), with 7 out of 12 patients showing an improvement of more than 5 letters. After 4 weeks, there was an improvement of more than 10 letters in 3 patients (mean + 5.7 letters; p = 0.001; T test) whereas at 6 months a loss of 1.6 letters was observed. Only 4 (33%) of our patients did not show any improvement at all. Contrast sensitivity displayed a similar pattern. Within one week after treatment, there was a rapid improvement (+4.4 optotypes; p = 0.006; T test). After 6 months, contrast sensitivity declined again (+1.5 optotypes; p = 0.2; T test). Compared to the placebo group changes on VA failed statistical significance (p = 0.1 at 4 week; T test) whereas changes on contrast sensitivity were statistically significant (p = 0.01 at week 4; T test). No adverse events were seen or reported during the study period. To the best of our knowledge, this is the first report of a transpalpebral electrostimulation in patients with dry AMD that demonstrates a temporary increase in visual function in some of these patients; results that seem to justify further research on this potential treatment option for dry AMD.

  20. Hunger state affects both olfactory abilities and gustatory sensitivity.

    PubMed

    Hanci, Deniz; Altun, Huseyin

    2016-07-01

    Chemical senses such as odor, taste and appearance are directly related with appetite. Understanding the relation between appetite and flavor is getting more important due to increasing number of obese patients worldwide. The literature on the studies investigating the change in olfactory abilities and gustatory sensitivity mostly performed using food-related odors and tastes rather than standardized tests were developed to study olfaction and gustation. Therefore, results are inconsistent and the relationship between olfactory and gustatory sensitivity with respect to the actual state of human satiety is still not completely understood. Here, for the first time in literature, we investigated the change in both olfactory abilities and gustatory sensitivity in hunger and in satiety using 123 subjects (37 men, 86 women; mean age 31.4 years, age range 21-41 years). The standardized Sniffin' Sticks Extended Test and Taste Strips were used for olfactory testing and gustatory sensitivity, respectively. TDI score (range 1-48) was calculated as the collective scores of odor threshold (T), odor discrimination (D) and odor identification (I). The evaluation was performed in two successive days where the hunger state of test subjects was confirmed by blood glucose test strips (mean blood glucose level 90.0 ± 5.6 mg/dl in hunger and 131.4 ± 8.1 mg/dl in satiety). The results indicated statistically significant decrease in olfaction in satiety compared to hunger (mean TDI 39.3 ± 1.1 in hunger, 37.4 ± 1.1 in satiety, p < 0.001). The comparison of gustatory sensitivity indicated significantly higher sensitivity to sweet, sour and salty in hunger (p < 0.001), but significantly higher sensitivity to bitter tastant in satiety (p < 0.001). With this prospective study, we were able to show that both olfactory abilities and gustatory sensitivity were affected by hunger state.

  1. Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.

    PubMed

    De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil

    2015-12-01

    This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.

  2. Simple and robust resistive dual-axis accelerometer using a liquid metal droplet

    NASA Astrophysics Data System (ADS)

    Huh, Myoung; Won, Dong-Joon; Kim, Joong Gil; Kim, Joonwon

    2017-12-01

    This paper presents a novel dual-axis accelerometer that consists of a liquid metal droplet in a cone-shaped channel and an electrode layer with four Nichrome electrodes. The sensor uses the advantages of the liquid metal droplet (i.e., high surface tension, electrical conductivity, high density, and deformability). The cone-shaped channel imposes a restoring force on the liquid metal droplet. We conducted simulation tests to determine the appropriate design specifications of the cone-shaped channel. Surface modifications to the channel enhanced the nonwetting performance of the liquid metal droplet. The performances of the sensor were analyzed by a tilting test. When the acceleration was applied along the axial direction, the device showed 6 kΩ/g of sensitivity and negligible crosstalk between the X- and Y-axes. In a diagonal direction test, the device showed 4 kΩ/g of sensitivity.

  3. Predicting individual contrast sensitivity functions from acuity and letter contrast sensitivity measurements

    PubMed Central

    Thurman, Steven M.; Davey, Pinakin Gunvant; McCray, Kaydee Lynn; Paronian, Violeta; Seitz, Aaron R.

    2016-01-01

    Contrast sensitivity (CS) is widely used as a measure of visual function in both basic research and clinical evaluation. There is conflicting evidence on the extent to which measuring the full contrast sensitivity function (CSF) offers more functionally relevant information than a single measurement from an optotype CS test, such as the Pelli–Robson chart. Here we examine the relationship between functional CSF parameters and other measures of visual function, and establish a framework for predicting individual CSFs with effectively a zero-parameter model that shifts a standard-shaped template CSF horizontally and vertically according to independent measurements of high contrast acuity and letter CS, respectively. This method was evaluated for three different CSF tests: a chart test (CSV-1000), a computerized sine-wave test (M&S Sine Test), and a recently developed adaptive test (quick CSF). Subjects were 43 individuals with healthy vision or impairment too mild to be considered low vision (acuity range of −0.3 to 0.34 logMAR). While each test demands a slightly different normative template, results show that individual subject CSFs can be predicted with roughly the same precision as test–retest repeatability, confirming that individuals predominantly differ in terms of peak CS and peak spatial frequency. In fact, these parameters were sufficiently related to empirical measurements of acuity and letter CS to permit accurate estimation of the entire CSF of any individual with a deterministic model (zero free parameters). These results demonstrate that in many cases, measuring the full CSF may provide little additional information beyond letter acuity and contrast sensitivity. PMID:28006065

  4. Prevalence of allergic sensitization in the U.S.: Results from the National Health and Nutrition Examination Survey (NHANES) 2005–2006

    PubMed Central

    Salo, Päivi M.; Arbes, Samuel J.; Jaramillo, Renee; Calatroni, Agustin; Weir, Charles H.; Sever, Michelle L.; Hoppin, Jane A.; Rose, Kathryn M.; Liu, Andrew H.; Gergen, Peter J.; Mitchell, Herman E.; Zeldin, Darryl C.

    2014-01-01

    Background Allergic sensitization is an important risk factor for the development of atopic disease. The National Health and Nutrition Examination Survey (NHANES) 2005–2006 provides the most comprehensive information on IgE-mediated sensitization in the general US population. Objective We investigated clustering, sociodemographic and regional patterns of allergic sensitization and examined risk factors associated with IgE-mediated sensitization. Methods Data for this cross-sectional analysis were obtained from NHANES 2005–2006. Participants aged ≥1 year (N=9440) were tested for sIgEs to inhalant and food allergens; participants ≥6 years were tested for 19 sIgEs, and children aged 1–5 years for 9 sIgEs. Serum samples were analyzed using the ImmunoCAP System. Information on demographics and participant characteristics was collected by questionnaire. Results Of the study population aged 6 and older, 44.6% had detectable sIgEs, while 36.2% of children aged 1–5 years were sensitized to ≥1 allergen. Allergen-specific IgEs clustered into 7 groups that might have largely reflected biological cross-reactivity. Although sensitization to individual allergens and allergen types showed regional variation, the overall prevalence of sensitization did not differ across census regions, except in early childhood. In multivariate modeling, young age, male gender, non-Hispanic black race/ethnicity, geographic location (census region), and reported pet avoidance measures were most consistently associated with IgE-mediated sensitization. Conclusions The overall prevalence of allergic sensitization does not vary across US census regions, except in early life, although allergen-specific sensitization differs by sociodemographic and regional factors. Biological cross-reactivity may be an important, but not a sole, contributor to the clustering of allergen-specific IgEs. Clinical implications IgE-mediated sensitization shows clustering patterns and differs by sociodemographic and regional factors, but the overall prevalence of sensitization may not vary across US census regions. PMID:24522093

  5. Test-Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease.

    PubMed

    Palkovits, Stefan; Hirnschall, Nino; Georgiev, Stefan; Leisser, Christoph; Findl, Oliver

    2018-02-01

    To evaluate the test-retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test-retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] -1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR -1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. The microperimeter MP3 shows an adequate test-retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.

  6. In Vitro Sensitivity and Resistance of 46 Leptospira Strains Isolated from Rats in the Philippines to 14 Antimicrobial Agents▿ †

    PubMed Central

    Chakraborty, Antara; Miyahara, Satoshi; Villanueva, Sharon Y. A. M.; Gloriani, Nina G.; Yoshida, Shin-ichi

    2010-01-01

    The in vitro susceptibilities of 46 Leptospira isolates from rats to 14 antimicrobial agents were tested. All of the strains were found to be sensitive to ampicillin, cefotaxime, ciprofloxacin, norfloxacin, doxycycline, erythromycin, and streptomycin. In contrast, the tested isolates showed resistance to amphotericin B, 5-fluorouracil, fosfomycin, trimethoprim, sulfamethoxazole, neomycin, and vancomycin. These findings will help in selecting effective and ineffective antimicrobials for treatment of leptospirosis and for the development of new selective media, respectively. PMID:20855741

  7. Normative values for a tablet computer-based application to assess chromatic contrast sensitivity.

    PubMed

    Bodduluri, Lakshmi; Boon, Mei Ying; Ryan, Malcolm; Dain, Stephen J

    2018-04-01

    Tablet computer displays are amenable for the development of vision tests in a portable form. Assessing color vision using an easily accessible and portable test may help in the self-monitoring of vision-related changes in ocular/systemic conditions and assist in the early detection of disease processes. Tablet computer-based games were developed with different levels of gamification as a more portable option to assess chromatic contrast sensitivity. Game 1 was designed as a clinical version with no gaming elements. Game 2 was a gamified version of game 1 (added fun elements: feedback, scores, and sounds) and game 3 was a complete game with vision task nested within. The current study aimed to determine the normative values and evaluate repeatability of the tablet computer-based games in comparison with an established test, the Cambridge Colour Test (CCT) Trivector test. Normally sighted individuals [N = 100, median (range) age 19.0 years (18-56 years)] had their chromatic contrast sensitivity evaluated binocularly using the three games and the CCT. Games 1 and 2 and the CCT showed similar absolute thresholds and tolerance intervals, and game 3 had significantly lower values than games 1, 2, and the CCT, due to visual task differences. With the exception of game 3 for blue-yellow, the CCT and tablet computer-based games showed similar repeatability with comparable 95% limits of agreement. The custom-designed games are portable, rapid, and may find application in routine clinical practice, especially for testing younger populations.

  8. Pressure-Sensitive Paint: Effect of Substrate

    PubMed Central

    Quinn, Mark Kenneth; Yang, Leichao; Kontis, Konstantinos

    2011-01-01

    There are numerous ways in which pressure-sensitive paint can be applied to a surface. The choice of substrate and application method can greatly affect the results obtained. The current study examines the different methods of applying pressure-sensitive paint to a surface. One polymer-based and two porous substrates (anodized aluminum and thin-layer chromatography plates) are investigated and compared for luminescent output, pressure sensitivity, temperature sensitivity and photodegradation. Two luminophores [tris-Bathophenanthroline Ruthenium(II) Perchlorate and Platinum-tetrakis (pentafluorophenyl) Porphyrin] will also be compared in all three of the substrates. The results show the applicability of the different substrates and luminophores to different testing environments. PMID:22247685

  9. [Effect of genotype and day or night time of testing on mice behavior in the light-dark box and the open-field tests].

    PubMed

    Morozova, M V; Kulikov, A V

    2010-01-01

    The light-dark box (LDB) and the open-field (OF) tests are widespread experimental models for studying locomotion and anxiety in laboratory rats and mice. The fact that rodents are nocturnal animals and more active at night raises a critical question of whether behavioral experiments carried out in the light phase are methodologically correct. Parameters of behavior of four mouse strains (C57BL/6J, DBA2/J, AKR/J and CBA/LacJ) in the light-dark box and open-field tests in the light and dark phases were compared. No significant influence of the phase of testing on anxiety in LDB and OF tests was revealed. In the OF test CBA mice showed increased locomotor activity, whereas AKR and C57BL/6 mice showed increased defecation in the dark phase. It was concluded that: 1) the phase of testing is not crucial for the expression of anxiety in LDB and OF; 2) the sensitivity to the phase of testing depends on the genotype; 3) the indices of behavior in the genotypes sensitive to the phase of testing (locomotion in the CBA and defecation in the AKR and C57BL/6 mouse strains) are increased in the dark phase.

  10. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    NASA Astrophysics Data System (ADS)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c

  11. Screening for colon cancer: A test for occult blood.

    PubMed

    Khakimov, N; Khasanova, G; Ershova, K; Gibadullina, L; Vetkina, T; Lobisheva, G; Chumakova, A

    2015-01-01

    The relevance of the problem of colorectal cancer (CRC) is evident because of extremely high morbidity and mortality rates, associated with this disease. CRC is mostly diagnosed only at very advanced stages. The reduction of mortality can be achieved by the popularization of screening-methods for early identification of CRC and adenomatous polyps of the colon, which are proved to be precancerous condition. Fecal occult blood test is a well-known method of screening for CRC. The advantages of this method when compared, for example, with colonoscopy are its simplicity and cost-effectiveness.Two techniques are usually used for detection of occult blood in the stool: Hemoccult (Guaiac) test and immunochemical test for hemoglobin. There is no consensus among researchers regarding the validity of these tests for the diagnosis of colorectal cancer. For example, J.S. Mandel (1996) notes 60% sensitivity of Guaiac-test for the detection of the early forms of colorectal cancer, while O.I. Kit (2014) suggets that it is not higher than 30%. There are also various opinions about specificity of these two tests. To review the literature on the validity of the fecal occult blood tests for the diagnosis of CRC. We looked for articles (electronic versions) available for free in the full-text versions, published from June 1, 1990 to December 31, 2014 in Russian or English. The following databases were used for search: E-LIBRARY; Cochrane; MEDLINE; EMBASE; Google search. Only original research papers were analyzed. Literature reviews or systematic reviews were not taken for analyses. 1) use of Guaiac and/or immunochemical fecal occult blood test as screening-tests for the detection of colorectal cancer and/or colon polyps (1 cm or more in diameter) in people older than 45 years; 2) comparing of results with the results of colonoscopy (colonoscopy is counted by majority of the authors as a "gold standard" for the diagnosis of CRC and adenomatous polyps). Initial keyword search returned 803 000 results, of which 449 sources were selected. After reading the abstracts, 29 articles that met inclusion criteria were kept. 10 other articles were excluded after that because they did not contain enough data for extraction or did not contain a control group. At the final step 19 articles were used for meta-analysis.Forest plot and Rock curve, which were developed with inclusion of the data from all studies, showed heterogeneity of the data. Additional analyzes were performed in subgroups with different diagnoses and various tests.The sensitivity of the Guaiac test for the diagnosis of colorectal cancer varied from 0.13 to 1.00, and specificity - from 0.69 to 0.99. The sensitivity of the immunochemical test for the diagnosis of CRC ranged from 0.42 to 0.94 with specificity ranging from 0.40 to 1.00.The sensitivity of the Guaiac test for the diagnosis of the colon polyps was between 0.05 and 0.69, and its specificity - from 0.67 to 0.98. The sensitivity of the immunochemical test for the diagnosis of polyps was from 0.24 to 0.75, and its specificity - from 0.40 to 0.97.Bivariate analysis of the validity of Guaiac test and immunochemical method for the diagnosis of colorectal cancer showed better results for the immunochemical test compared to Guaiac test. The tests showed very similar results when used for the diagnosis of polyposis. Bivariate analysis, comparing the validity of tests for the diagnosis of colorectal cancer versus polyposis demonstrated better results for CRC.Multivariate analysis of the validity of the Guaiac and immunochemical tests for the diagnosis of colorectal cancer and polyps also showed better results for detection of colorectal cancer compared with the polyps for both tests. At the same time the highest validity for the diagnosis of CRC was demonstrated for immunochemical analysis. 1. The sensitivity of the Guaiac test for occult blood in stool is lower than its specificity.2. Broad dispersion of the validity characteristics of the fecal occult blood tests was observed.3. The validity of tests for occult blood was higher when they were used for detection of colorectal cancer than of colon polyposis.4. The highest validity rate has been demonstrated for the immunochemical test when it was used for colon cancer screening.

  12. Integrated Computational Solution for Predicting Skin Sensitization Potential of Molecules

    PubMed Central

    Desai, Aarti; Singh, Vivek K.; Jere, Abhay

    2016-01-01

    Introduction Skin sensitization forms a major toxicological endpoint for dermatology and cosmetic products. Recent ban on animal testing for cosmetics demands for alternative methods. We developed an integrated computational solution (SkinSense) that offers a robust solution and addresses the limitations of existing computational tools i.e. high false positive rate and/or limited coverage. Results The key components of our solution include: QSAR models selected from a combinatorial set, similarity information and literature-derived sub-structure patterns of known skin protein reactive groups. Its prediction performance on a challenge set of molecules showed accuracy = 75.32%, CCR = 74.36%, sensitivity = 70.00% and specificity = 78.72%, which is better than several existing tools including VEGA (accuracy = 45.00% and CCR = 54.17% with ‘High’ reliability scoring), DEREK (accuracy = 72.73% and CCR = 71.44%) and TOPKAT (accuracy = 60.00% and CCR = 61.67%). Although, TIMES-SS showed higher predictive power (accuracy = 90.00% and CCR = 92.86%), the coverage was very low (only 10 out of 77 molecules were predicted reliably). Conclusions Owing to improved prediction performance and coverage, our solution can serve as a useful expert system towards Integrated Approaches to Testing and Assessment for skin sensitization. It would be invaluable to cosmetic/ dermatology industry for pre-screening their molecules, and reducing time, cost and animal testing. PMID:27271321

  13. Identification of precision treatment strategies for relapsed/refractory multiple myeloma by functional drug sensitivity testing.

    PubMed

    Majumder, Muntasir Mamun; Silvennoinen, Raija; Anttila, Pekka; Tamborero, David; Eldfors, Samuli; Yadav, Bhagwan; Karjalainen, Riikka; Kuusanmäki, Heikki; Lievonen, Juha; Parsons, Alun; Suvela, Minna; Jantunen, Esa; Porkka, Kimmo; Heckman, Caroline A

    2017-08-22

    Novel agents have increased survival of multiple myeloma (MM) patients, however high-risk and relapsed/refractory patients remain challenging to treat and their outcome is poor. To identify novel therapies and aid treatment selection for MM, we assessed the ex vivo sensitivity of 50 MM patient samples to 308 approved and investigational drugs. With the results we i) classified patients based on their ex vivo drug response profile; ii) identified and matched potential drug candidates to recurrent cytogenetic alterations; and iii) correlated ex vivo drug sensitivity to patient outcome. Based on their drug sensitivity profiles, MM patients were stratified into four distinct subgroups with varied survival outcomes. Patients with progressive disease and poor survival clustered in a drug response group exhibiting high sensitivity to signal transduction inhibitors. Del(17p) positive samples were resistant to most drugs tested with the exception of histone deacetylase and BCL2 inhibitors. Samples positive for t(4;14) were highly sensitive to immunomodulatory drugs, proteasome inhibitors and several targeted drugs. Three patients treated based on the ex vivo results showed good response to the selected treatments. Our results demonstrate that ex vivo drug testing may potentially be applied to optimize treatment selection and achieve therapeutic benefit for relapsed/refractory MM.

  14. Vibration Sensitivity of a Wide-Temperature Electronically Scanned Pressure Measurement (ESP) Module

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J.; Garza, Frederico R.

    2001-01-01

    A vibration sensitivity test was conducted on a Wide-Temperature ESP module. The test object was Module "M4," a 16-channel, 4 psi unit scheduled for installation in the Arc Sector of NTF. The module was installed on a vibration exciter and loaded to positive then negative full-scale pressures (+/-2.5 psid). Test variables were the following: Vibration frequencies: 20, 55, 75 Hz. Vibration level: 1 g. Vibration axes: X, Y, Z. The pressure response was measured on each channel, first without and then with the vibration turned on, and the difference analyzed by means of the statistical t-test. The results show that the vibration sensitivity does not exceed 0.01% Full Scale Output per g (with the exception of one channel on one axis) to a 95 percent confidence level. This specification, limited by the resolution of the pressure source, lies well below the total uncertainty specification of 0.1 percent Full Scale Output.

  15. Accurate Detection of Streptococcus pyogenes at the Point of Care Using the cobas Liat Strep A Nucleic Acid Test.

    PubMed

    Wang, Fangnian; Tian, Yu; Chen, Lingjun; Luo, Robert; Sickler, Joanna; Liesenfeld, Oliver; Chen, Shuqi

    2017-10-01

    The performance of a polymerase chain reaction-based point-of-care assay, the cobas Strep A Nucleic Acid Test for use on the cobas Liat System (cobas Liat Strep A assay), for the detection of group A Streptococcus bacteria was evaluated in primary care settings. Throat swab specimens from 427 patients were tested with the cobas Liat Strep A assay and a rapid antigen detection test (RADT) by existing medical staff at 5 primary care clinics, and results were compared with bacterial culture. The cobas Liat Strep A assay demonstrated equivalent sensitivity (97.7%) and specificity (93.3%) to reference culture with a 15-minute turnaround time. In comparison to RADTs, the cobas Liat Strep A assay showed improved sensitivity (97.7% Liat vs 84.5% RADT). The Clinical Laboratory Improvement Amendments-waived cobas Liat Strep A assay demonstrated the ease of use and improved turnaround time of RADTs along with the sensitivity of culture.

  16. Low sensitivity of malaria rapid diagnostic tests stored at room temperature in the Brazilian Amazon Region.

    PubMed

    Gomes, Luciano T; Tada, Mauro S; Katsuragawa, Tony H; Povoa, Marinete M; Viana, Giselle Mr; Alecrim, Maria das Gracas C; De Santana-Filho, Frankllin S; Arcanjo, Ana Ruth L; Couto, Alvaro A R A; Calvosa, Vanja S P; Nery, Andreia F; Fontes, Cor J F

    2013-03-14

    In remote areas of the Amazon Region, diagnosis of malaria by microscopy is practically impossible. This study aimed to evaluate the performance of two rapid diagnostic tests (RDTs) targeting different malaria antigens stored at room temperature in the Brazilian Amazon Region. Performance of the OptiMal Pf/Pan test and ICT-Now Pf/Pan test was analyzed retrospectively in 1,627 and 1,602 blood samples, respectively. Tests were performed over a 15-month period. Kits were stored at room temperature in five community health centres located in the Brazilian Amazon Region. RDT results were compared with thick blood smear (TBS) results to determine sensitivity, specificity, and accuracy of the RDT. The sensitivities of the OptiMal Pf/Pan test were 79.7% for Plasmodium falciparum malaria diagnosis and 85.7% for non-P. falciparum infections. The results showed a crude agreement of 88.5% for P. falciparum, and 88.3% for non-P. falciparum infections (Kappa index = 0.74 and 0.75, respectively). For the ICT-Now Pf/Pan test (CI 95%), the sensitivities were 87.9% for P. falciparum malaria diagnosis and 72.5% for non-P. falciparum infection. Crude agreement between the ICT-Now Pf/Pan test and TBS was 91.4% for P. falciparum and 79.7% for non-P. falciparum infection. The Kappa index was 0.81 and 0.59 for the final diagnosis of P. falciparum and non-P. falciparum, respectively. Higher levels of parasitaemia were associated with higher crude agreement between RDT and TBS. The sensitivities of RDTs stored at room temperature over a 15-month period and performed in field conditions were lower than those previously reported.

  17. Prevalence of gestational diabetes mellitus based on various screening strategies in western Kenya: a prospective comparison of point of care diagnostic methods.

    PubMed

    Pastakia, Sonak D; Njuguna, Benson; Onyango, Beryl Ajwang'; Washington, Sierra; Christoffersen-Deb, Astrid; Kosgei, Wycliffe K; Saravanan, Ponnusamy

    2017-07-14

    Early diagnosis of gestational diabetes mellitus (GDM) is crucial to prevent short term delivery risks and long term effects such as cardiovascular and metabolic diseases in the mother and infant. Diagnosing GDM in Sub-Saharan Africa (SSA) however, remains sub-optimal due to associated logistical and cost barriers for resource-constrained populations. A cost-effective strategy to screen for GDM in such settings are therefore urgently required. We conducted this study to determine the prevalence of gestational diabetes mellitus (GDM) and assess utility of various GDM point of care (POC) screening strategies in a resource-constrained setting. Eligible women aged ≥18 years, and between 24 and 32 weeks of a singleton pregnancy, prospectively underwent testing over two days. On day 1, a POC 1-h 50 g glucose challenge test (GCT) and a POC glycated hemoglobin (HbA1c) was assessed. On day 2, fasting blood glucose, 1-h and 2-h 75 g oral glucose tolerance test (OGTT) were determined using both venous and POC tests, along with a venous HbA1c. The International Association of Diabetes in Pregnancy Study Group (IADPSG) criteria was used to diagnose GDM. GDM prevalence was reported with 95% confidence interval (CI). Specificity, sensitivity, positive predictive value, and negative predictive value of the various POC testing strategies were determined using IADPSG testing as the standard reference. Six hundred-sixteen eligible women completed testing procedures. GDM was diagnosed in 18 women, a prevalence of 2.9% (95% CI, 1.57% - 4.23%). Compared to IADPSG testing, POC IADPSG had a sensitivity and specificity of 55.6% and 90.6% respectively while that of POC 1-h 50 g GCT (using a diagnostic cut-off of ≥7.2 mmol/L [129.6 mg/dL]) was 55.6% and 63.9%. All other POC tests assessed showed poor sensitivity. POC screening strategies though feasible, showed poor sensitivity for GDM detection in our resource-constrained population of low GDM prevalence. Studies to identify sensitive and specific POC GDM screening strategies using adverse pregnancy outcomes as end points are required. Clinical trials.gov : NCT02978807 , Registered 29 November 2016.

  18. Development of an in vitro skin sensitization test based on ROS production in THP-1 cells.

    PubMed

    Saito, Kazutoshi; Miyazawa, Masaaki; Nukada, Yuko; Sakaguchi, Hitoshi; Nishiyama, Naohiro

    2013-03-01

    Recently, it has been reported that reactive oxygen species (ROS) produced by contact allergens can affect dendritic cell migration and contact hypersensitivity. The aim of the present study was to develop a new in vitro assay that could predict the skin sensitizing potential of chemicals by measuring ROS production in THP-1 (human monocytic leukemia cell line) cells. THP-1 cells were pre-loaded with a ROS sensitive fluorescent dye, 5-(and 6-)-chloromethyl-2', 7'-dichlorodihydrofluorescein diacetate, acetyl ester (CM-H2DCFDA), for 15min, then incubated with test chemicals for 30min. The fluorescence intensity was measured by flow cytometry. For the skin sensitizers, 25 out of 30 induced over a 2-fold ROS production at more than 90% of cell viability. In contrast, increases were only seen in 4 out of 20 non-sensitizers. The overall accuracy for the local lymph node assay (LLNA) was 82% for 50 chemicals tested. A correlation was found between the estimated concentration showing 2-fold ROS production in the ROS assay and the EC3 values (estimated concentration required to induce positive response) of the LLNA. These results indicated that the THP-1 cell-based ROS assay was a rapid and highly sensitive detection system able to predict skin sensitizing potentials and potency of chemicals. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Longitudinal Effects of Embryonic Exposure to Cocaine on Morphology, Cardiovascular Physiology, and Behavior in Zebrafish.

    PubMed

    Mersereau, Eric J; Boyle, Cody A; Poitra, Shelby; Espinoza, Ana; Seiler, Joclyn; Longie, Robert; Delvo, Lisa; Szarkowski, Megan; Maliske, Joshua; Chalmers, Sarah; Darland, Diane C; Darland, Tristan

    2016-05-31

    A sizeable portion of the societal drain from cocaine abuse results from the complications of in utero drug exposure. Because of challenges in using humans and mammalian model organisms as test subjects, much debate remains about the impact of in utero cocaine exposure. Zebrafish offer a number of advantages as a model in longitudinal toxicology studies and are quite sensitive physiologically and behaviorally to cocaine. In this study, we have used zebrafish to model the effects of embryonic pre-exposure to cocaine on development and on subsequent cardiovascular physiology and cocaine-induced conditioned place preference (CPP) in longitudinal adults. Larval fish showed a progressive decrease in telencephalic size with increased doses of cocaine. These treated larvae also showed a dose dependent response in heart rate that persisted 24 h after drug cessation. Embryonic cocaine exposure had little effect on overall health of longitudinal adults, but subtle changes in cardiovascular physiology were seen including decreased sensitivity to isoproterenol and increased sensitivity to cocaine. These longitudinal adult fish also showed an embryonic dose-dependent change in CPP behavior, suggesting an increased sensitivity. These studies clearly show that pre-exposure during embryonic development affects subsequent cocaine sensitivity in longitudinal adults.

  20. A principled approach to setting optimal diagnostic thresholds: where ROC and indifference curves meet.

    PubMed

    Irwin, R John; Irwin, Timothy C

    2011-06-01

    Making clinical decisions on the basis of diagnostic tests is an essential feature of medical practice and the choice of the decision threshold is therefore crucial. A test's optimal diagnostic threshold is the threshold that maximizes expected utility. It is given by the product of the prior odds of a disease and a measure of the importance of the diagnostic test's sensitivity relative to its specificity. Choosing this threshold is the same as choosing the point on the Receiver Operating Characteristic (ROC) curve whose slope equals this product. We contend that a test's likelihood ratio is the canonical decision variable and contrast diagnostic thresholds based on likelihood ratio with two popular rules of thumb for choosing a threshold. The two rules are appealing because they have clear graphical interpretations, but they yield optimal thresholds only in special cases. The optimal rule can be given similar appeal by presenting indifference curves, each of which shows a set of equally good combinations of sensitivity and specificity. The indifference curve is tangent to the ROC curve at the optimal threshold. Whereas ROC curves show what is feasible, indifference curves show what is desirable. Together they show what should be chosen. Copyright © 2010 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  1. Methicillin-Resistant Staphylococcus aureus: Comparison of Susceptibility Testing Methods and Analysis of mecA-Positive Susceptible Strains

    PubMed Central

    Sakoulas, George; Gold, Howard S.; Venkataraman, Lata; DeGirolami, Paola C.; Eliopoulos, George M.; Qian, Qinfang

    2001-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is responsible for an increasing number of serious nosocomial and community-acquired infections. Phenotypic heterogeneous drug resistance (heteroresistance) to antistaphylococcal beta-lactams affects the results of susceptibility testing. The present study compared the MRSA-Screen latex agglutination test (Denka Seiken Co., Ltd., Tokyo, Japan) for detection of PBP 2a with agar dilution, the VITEK-1 and VITEK-2 systems (bioMérieux, St. Louis, Mo.), and the oxacillin agar screen test for detection of MRSA, with PCR for the mecA gene used as the “gold standard” assay. Analysis of 107 methicillin-susceptible S. aureus (MSSA) isolates and 203 MRSA isolates revealed that the MRSA-Screen latex agglutination test is superior to any single phenotype-based susceptibility testing method, with a sensitivity of 100% and a specificity of 99.1%. Only one isolate that lacked mecA was weakly positive by the MRSA-Screen latex agglutination test. This isolate was phenotypically susceptible to oxacillin and did not contain the mecA gene by Southern blot hybridization. The oxacillin agar screen test, the VITEK-1 system, the VITEK-2 system, and agar dilution showed sensitivities of 99.0, 99.0, 99.5, and 99%, respectively, and specificities of 98.1, 100, 97.2, and 100%, respectively. The differences in sensitivity or specificity were not statistically significant. Oxacillin bactericidal assays showed that mecA- and PBP 2a-positive S. aureus isolates that are susceptible to antistaphylococcal beta-lactams by conventional methods are functionally resistant to oxacillin. We conclude that the accuracy of the MRSA-Screen latex agglutination method for detection of PBP 2a approaches the accuracy of PCR and is more accurate than any susceptibility testing method used alone for the detection of MRSA. PMID:11682512

  2. Improved Gustatory Sensitivity in Morbidly Obese Patients After Laparoscopic Sleeve Gastrectomy.

    PubMed

    Altun, Huseyin; Hanci, Deniz; Altun, Hasan; Batman, Burcin; Serin, Rahmi Kursat; Karip, Aziz Bora; Akyuz, Umit

    2016-07-01

    The reduction in the preferences for sweet and fat containing tastes in obese patients who underwent bariatric surgery was relatively well shown; however, there are only limited data on the changes in the sensitivity of other tastes like sour, salty, and bitter. We investigated the changes in gustatory sensitivity of 52 morbidly obese patients (M/F, 22/30; age range, 19-60 years; BMI range, 32.5-63.0 kg/m(2)) after laparoscopic sleeve gastrectomy. The surgery was performed by the same surgeon using 5 ports technique. Gustatory sensitivity was tested preoperatively and 1 and 3 months after the surgery using standardized Taste Strips test. There was a statistically significant improvement in the taste acuity to sweet, sour, salty, and bitter tastants in morbidly obese patients after the laparoscopic sleeve gastrectomy during the follow-up period of 3 months. Median whole test scores of the patients were increased from 11.5 preoperatively to 14 in the first and third months. In this study, we were able to show the significant improvement in gustatory sensitivity of morbidly obese patients after laparoscopic sleeve gastrectomy for the first time in literature. © The Author(s) 2016.

  3. p16/ki-67 dual-stain cytology in the triage of ASCUS and LSIL papanicolaou cytology: results from the European equivocal or mildly abnormal Papanicolaou cytology study.

    PubMed

    Schmidt, Dietmar; Bergeron, Christine; Denton, Karin J; Ridder, Ruediger

    2011-06-25

    The objective of this study was to analyze the diagnostic performance of a newly established immunocytochemical dual-stain protocol, which simultaneously detects p16(INK4a) and Ki-67 expression in cervical cytology samples, for identifying high-grade cervical intraepithelial neoplasia (CIN2+) in women with Papanicolaou (Pap) cytology results categorized as atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesions (LSIL). Residual liquid-based cytology material from 776 retrospectively collected ASCUS/LSIL cases that were available from a recent study evaluating p16 cytology and HPV testing were subjected to p16/Ki-67 dual staining. The presence of 1 or more double-immunoreactive cell(s) was regarded as a positive test outcome, irrespective of morphology. Test results were correlated to histology follow-up. Sensitivity of p16/Ki-67 dual-stain cytology for biopsy-confirmed CIN2+ was 92.2% (ASCUS) and 94.2% (LSIL), while specificity rates were 80.6% (ASCUS) and 68.0% (LSIL), respectively. Similar sensitivity/specificity profiles were found for both age groups of women aged <30 years versus women aged ≥30 years. Dual-stain cytology showed comparable sensitivity, but significantly higher specificity, when compared with human papillomavirus (HPV) testing. The results of this study show that p16/Ki-67 dual-stain cytology provided a high sensitivity for the detection of underlying CIN2+ in women with ASCUS or LSIL Pap cytology results, comparable to the rates previously reported for HPV testing and p16 single-stain cytology. However, the specificity of this morphology-independent interpretation of p16/Ki-67 dual-stain cytology testing was further improved compared with the earlier p16 single-stain cytology approach, which required morphology interpretation, and it is significantly higher when compared with HPV testing. Copyright © 2011 American Cancer Society.

  4. Glyceria maxima as new test species for the EU risk assessment for herbicides: a microcosm study.

    PubMed

    Mohr, S; Schott, J; Hoenemann, L; Feibicke, M

    2015-03-01

    In its recent guidance document on tiered risk assessment for plant protection products for aquatic organisms, the European Food Safety Authority (EFSA) proposed to use Glyceria maxima as monocotyledonous grass species for the testing of special herbicide groups. However, published toxicity data for this species is very limited and there is no test guideline for Glyceria sp. For this reason a microcosm study was conducted in order to gain experience on the degree of sensitivity of G. maxima to the herbicidal substances clodinafop-propargyl (grass herbicide) and fluroxypyr (auxin) in comparison to the already established test organism water milfoil Myriophyllum spicatum and the duckweed species Landoltia punctata. Five concentrations without replicates were tested for each test substance using 10 microcosms and three microcosms served as controls. The experiment was run for 8 weeks. Morphological endpoints were used to determine growth and EC50 values. The results show that M. spicatum was most sensitive to fluroxypyr (37 days EC50 for roots: 62 µg/L) and G. maxima most sensitive to clodinafop-propargyl (22 days EC50 for total shoot length: 48 µg/L) whereas the duckweed species was considerable less sensitive. Hence, G. maxima turns out to be a good candidate for testing grass specific herbicides, supporting its inclusion as an additional macrophyte test for the risk assessment of herbicides as proposed by the EFSA.

  5. A framework for comparing structural and functional measures of glaucomatous damage

    PubMed Central

    Hood, Donald C.; Kardon, Randy H.

    2007-01-01

    While it is often said that structural damage due to glaucoma precedes functional damage, it is not always clear what this statement means. This review has two purposes: first, to show that a simple linear relationship describes the data relating a particular functional test (standard automated perimetry (SAP)) to a particular structural test (optical coherence tomography (OCT)); and, second, to propose a general framework for relating structural and functional damage, and for evaluating if one precedes the other. The specific functional and structural tests employed are described in Section 2. To compare SAP sensitivity loss to loss of the retinal nerve fiber layer (RNFL) requires a map that relates local field regions to local regions of the optic disc as described in Section 3. When RNFL thickness in the superior and inferior arcuate sectors of the disc are plotted against SAP sensitivity loss (dB units) in the corresponding arcuate regions of the visual field, RNFL thickness becomes asymptotic for sensitivity losses greater than about 10 dB. These data are well described by a simple linear model presented in Section 4. The model assumes that the RNFL thickness measured with OCT has two components. One component is the axons of the retinal ganglion cells and the other, the residual, is everything else (e.g. glial cells, blood vessels). The axon portion is assumed to decrease in a linear fashion with losses in SAP sensitivity (in linear units); the residual portion is assumed to remain constant. Based upon severe SAP losses in anterior ischemic optic neuropathy (AION), the residual RNFL thickness in the arcuate regions is, on average, about one-third of the premorbid (normal) thickness of that region. The model also predicts that, to a first approximation, SAP sensitivity in control subjects does not depend upon RNFL thickness. The data (Section 6) are, in general, consistent with this prediction showing a very weak correlation between RNFL thickness and SAP sensitivity. In Section 7, the model is used to estimate the proportion of patients showing statistical abnormalities (worse than the 5th percentile) on the OCT RNFL test before they show abnormalities on the 24-2 SAP field test. Ignoring measurement error, the patients with a relatively thick RNFL, when healthy, will be more likely to show significant SAP sensitivity loss before statistically significant OCT RNFL loss, while the reverse will be true for those who start with an average or a relatively thin RNFL when healthy. Thus, it is important to understand the implications of the wide variation in RNFL thickness among control subjects. Section 8 describes two of the factors contributing to this variation, variations in the position of blood vessels and variations in the mapping of field regions to disc sectors. Finally, in Sections 7 and 9, the findings are related to the general debate in the literature about the relationship between structural and functional glaucomatous damage and a framework is proposed for understanding what is meant by the question, ‘Does structural damage precede functional damage in glaucoma?’ An emphasis is placed upon the need to distinguish between “statistical” and “relational” meanings of this question. PMID:17889587

  6. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function.

    PubMed

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A; Lu, Zhong-Lin; Myung, Jay I

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias.

  7. A hierarchical Bayesian approach to adaptive vision testing: A case study with the contrast sensitivity function

    PubMed Central

    Gu, Hairong; Kim, Woojae; Hou, Fang; Lesmes, Luis Andres; Pitt, Mark A.; Lu, Zhong-Lin; Myung, Jay I.

    2016-01-01

    Measurement efficiency is of concern when a large number of observations are required to obtain reliable estimates for parametric models of vision. The standard entropy-based Bayesian adaptive testing procedures addressed the issue by selecting the most informative stimulus in sequential experimental trials. Noninformative, diffuse priors were commonly used in those tests. Hierarchical adaptive design optimization (HADO; Kim, Pitt, Lu, Steyvers, & Myung, 2014) further improves the efficiency of the standard Bayesian adaptive testing procedures by constructing an informative prior using data from observers who have already participated in the experiment. The present study represents an empirical validation of HADO in estimating the human contrast sensitivity function. The results show that HADO significantly improves the accuracy and precision of parameter estimates, and therefore requires many fewer observations to obtain reliable inference about contrast sensitivity, compared to the method of quick contrast sensitivity function (Lesmes, Lu, Baek, & Albright, 2010), which uses the standard Bayesian procedure. The improvement with HADO was maintained even when the prior was constructed from heterogeneous populations or a relatively small number of observers. These results of this case study support the conclusion that HADO can be used in Bayesian adaptive testing by replacing noninformative, diffuse priors with statistically justified informative priors without introducing unwanted bias. PMID:27105061

  8. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    PubMed

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  9. Laboratory and Field Evaluation of a New Rapid Test for Detecting Wuchereria bancrofti Antigen in Human Blood

    PubMed Central

    Weil, Gary J.; Curtis, Kurt C.; Fakoli, Lawrence; Fischer, Kerstin; Gankpala, Lincoln; Lammie, Patrick J.; Majewski, Andrew C.; Pelletreau, Sonia; Won, Kimberly Y.; Bolay, Fatorma K.; Fischer, Peter U.

    2013-01-01

    Global Program to Eliminate Lymphatic Filariasis (GPELF) guidelines call for using filarial antigen testing to identify endemic areas that require mass drug administration (MDA) and for post-MDA surveillance. We compared a new filarial antigen test (the Alere Filariasis Test Strip) with the reference BinaxNOW Filariasis card test that has been used by the GPELF for more than 10 years. Laboratory testing of 227 archived serum or plasma samples showed that the two tests had similar high rates of sensitivity and specificity and > 99% agreement. However, the test strip detected 26.5% more people with filarial antigenemia (124/503 versus 98/503) and had better test result stability than the card test in a field study conducted in a filariasis-endemic area in Liberia. Based on its increased sensitivity and other practical advantages, we believe that the test strip represents a major step forward that will be welcomed by the GPELF and the filariasis research community. PMID:23690552

  10. The protective effects of free wheel-running against cocaine psychomotor sensitization persist after exercise cessation in C57BL/6J mice.

    PubMed

    Lespine, L-F; Tirelli, E

    2015-12-03

    Previous literature suggests that free access to a running wheel can attenuate the behavioral responsiveness to addictive drugs in rodents. In a few studies, wheel-running cessation accentuated drug responsiveness. Here, we tested whether free wheel-running cessation is followed by (1) an accentuation or (2) an attenuation of cocaine psychomotor sensitization, knowing that no cessation of (continuous) wheel-running is associated with an attenuation of cocaine responsiveness. Male C57BL/6J mice, aged 35 days, were housed singly either with (exercising mice) or without (non-exercising mice) a running wheel. At the end of a period of 36 days, half of the exercising mice were deprived of their wheel whereas the other half of exercising mice kept their wheel until the end of experimentation (which lasted 85 days). The non-exercising mice were housed without wheel throughout experimentation. Testing took place 3 days after exercise cessation. After 2 once-daily drug-free test sessions, mice were tested for initiation of psychomotor sensitization over 13 once-daily injections of 8 mg/kg cocaine. Post-sensitization conditioned activation (saline challenge) and long-term expression of sensitization were assessed 2 or 30 days after the last sensitizing injection (same treatments as for initiation of sensitization), respectively. Exercising mice and mice undergoing wheel-running cessation exhibited comparable degrees of attenuation of all cocaine effects in comparison with the continuously non-exercising mice, which showed the greatest effects. Thus, the efficaciousness of wheel-running at attenuating cocaine sensitization not only resisted to exercise cessation but was also unambiguously persistent (an important effect rarely reported in previous literature). Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  11. Nasal carriage of Methicillin- and Mupirocin-resistant S. aureus among health care workers in a tertiary care hospital.

    PubMed

    Agarwal, Loveleena; Singh, Amit Kumar; Sengupta, Chandrim; Agarwal, Amitabh

    2015-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) ranks top among the nosocomial pathogens. Nasal formulation of mupirocin is found to eradicate MRSA from colonized individuals, but the emergence of resistant strains is a matter of concern. Nasal swabs were collected from 200 health care workers (HCWs) who were screened for MRSA. Kirby-Bauer disc diffusion method was used to perform antibiotic susceptibility test. MRSA detection was done using a cefoxitin 30 µg disc and interpreted according to the Clinical and Laboratory Standards Institute guidelines. Determination of mupirocin resistance was performed using Epsilometer test (E-test). About 14% of HCWs showed nasal carriage of MRSA. Nursing orderlies were the predominant carriers. E-test showed four mupirocin resistant isolates. The antibiogram of the MRSA isolates revealed the higher resistance to antibiotics as compared to methicillin-sensitive Staphylococcus aureus. All the MRSA isolates were sensitive to linezolid. HCWs in our hospital showed high nasal carriage rate of MRSA, particularly the nursing orderlies which is statistically significant. It is advisable to detect mupirocin resistance among the isolates obtained from the HCWs so that in case of resistance, alternative treatment should be sought.

  12. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    PubMed Central

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Background Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. Objective To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. Methods In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). Results The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m2. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Conclusion Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction. PMID:24061685

  13. Enhanced Area of Secondary Hyperalgesia in Women with Multiple Stressful Life Events: A Pilot Study.

    PubMed

    You, Dokyoung S; Creech, Suzannah K; Meagher, Mary W

    2016-10-01

    Stressful life events are associated with increased pain severity and chronicity. However, the mechanism underlying this association remains disputed. Recent animal studies suggest that chronic stress increases pain sensitivity and persistence by enhancing peripheral and central sensitization mechanisms. To test this hypothesis in humans, the authors examined whether sensitization is enhanced in healthy women reporting more stressful life events using the topical capsaicin test. Thirty-two healthy young women reporting varying levels of stressful life events were invited for laboratory pain testing. Capsaicin was applied topically to the volar forearm. Measurements included capsaicin-induced spontaneous pain and area of secondary hyperalgesia in the region surrounding capsaicin application. Physiological (heart rate and skin conductance) and self-reported affective (emotional valence and arousal) states were also measured. The results indicate that more stressful life events predicted a linear increase in the area of secondary hyperalgesia (β = 0.40, p = 0.023, R 2 = 0.16), but not the intensity of secondary hyperalgesia nor capsaicin-induced spontaneous pain. These findings suggest that life stressors may be associated with heightened central sensitization manifested by an increased area of secondary hyperalgesia. Additionally, life stressors were related to greater sympathetic cardiac, but not to affective responses to capsaicin-induced pain. This study shows that women reporting more stressful life events show a larger area of secondary mechanical hyperalgesia. These preliminary findings suggest that life stressors may facilitate pain processing by enhancing central sensitization. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Time-dependent edge notch sensitivity of Inconel 718 sheet in the temperature range 900 to 1400 F (482 to 760 C)

    NASA Technical Reports Server (NTRS)

    Wilson, D. J.

    1972-01-01

    Time-dependent notch sensitivity of Inconel 718 sheet occurred at 900 to 1200 F when notched specimens were loaded below the yield strength, and tests on smooth specimens showed that small amounts of creep consumed large fractions of creep-rupture life. The severity of the notch sensitivity decreased with decreasing solution treatment temperature and increasing time and/or temperature of the aging treatment. Elimination of the notch sensitivity was correlated with a change in the dislocation mechanism from shearing to by-passing precipitate particles.

  15. Sensitivity Study of Ice Crystal Optical Properties in the 874 GHz Submillimeter Band

    NASA Technical Reports Server (NTRS)

    Tang, Guanglin; Yang, Ping; Wu, Dong L.

    2015-01-01

    Testing of an 874 GHz submillimeter radiometer on meteorological satellites is being planned to improve ice water content retrievals. In this paper we study the optical properties of ice cloud particles in the 874 GHz band. The results show that the bulk scattering and absorption coefficients of an ensemble of ice cloud particles are sensitive to the particle shape and effective diameter, whereas the latter is also sensitive to temperature. The co-polar back scattering cross-section is not sensitive to particle shape, temperature, and the effective diameter in the range of 50200 m.

  16. [A new assessment for episodic memory. Episodic memory test and caregiver's episodic memory test].

    PubMed

    Ojea Ortega, T; González Álvarez de Sotomayor, M M; Pérez González, O; Fernández Fernández, O

    2013-10-01

    The purpose of the episodic memory test and the caregiver's episodic memory test is to evaluate episodic memory according to its definition in a way that is feasible for families and achieves high degrees of sensitivity and specificity. We administered a test consisting of 10 questions about episodic events to 332 subjects, of whom 65 had Alzheimer's disease (AD), 115 had amnestic MCI (aMCI) and 152 showed no cognitive impairment according to Reisberg's global deterioration scale (GDS). We calculated the test's sensitivity and specificity to distinguish AD from episodic aMCI and from normal ageing. The area under the ROC curve for the diagnosis of aMCI was 0.94 and the best cut-off value was 20; for that value, sensitivity was 89% and specificity was 82%. For a diagnosis of AD, the area under the ROC curve was 0.99 and the best cut-off point was 17, with a sensitivity of 98% and a specificity of 91%. A subsequent study using similar methodology yielded similar results when the test was administered directly by the caregiver. The episodic memory test and the caregiver's episodic memory test are useful as brief screening tools for identifying patients with early-stage AD. It is suitable for use by primary care medical staff and in the home, since it can be administered by a caregiver. The test's limitations are that it must be administered by a reliable caregiver and the fact that it measures episodic memory only. Copyright © 2012 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  17. Direct detection of falciparum and non-falciparum malaria DNA from a drop of blood with high sensitivity by the dried-LAMP system.

    PubMed

    Hayashida, Kyoko; Kajino, Kiichi; Simukoko, Humphrey; Simuunza, Martin; Ndebe, Joseph; Chota, Amos; Namangala, Boniface; Sugimoto, Chihiro

    2017-01-13

    Because of the low sensitivity of conventional rapid diagnostic tests (RDTs) for malaria infections, the actual prevalence of the diseases, especially those caused by non-Plasmodium falciparum (non-Pf) species, in asymptomatic populations remain less defined in countries lacking in well-equipped facilities for accurate diagnoses. Our direct blood dry LAMP system (CZC-LAMP) was applied to the diagnosis of malaria as simple, rapid and highly sensitive method as an alternative for conventional RDTs in malaria endemic areas where laboratory resources are limited. LAMP primer sets for mitochondria DNAs of Plasmodium falciparum (Pf) and human-infective species other than Pf (non-Pf; P. vivax, P. ovale, P. malariae) were designed and tested by using human blood DNA samples from 74 residents from a malaria endemic area in eastern Zambia. These malaria dry-LAMPs were optimized for field or point-of-care operations, and evaluated in the field at a malaria endemic area in Zambia with 96 human blood samples. To determine the sensitivities and specificities, results obtained by the on-site LAMP diagnosis were compared with those by the nested PCR and nucleotide sequencing of its product. The dry LAMPs showed the sensitivities of 89.7% for Pf and 85.7% for non-Pf, and the specificities of 97.2% for Pf and 100% for non-Pf, with purified blood DNA samples. The direct blood LAMP diagnostic methods, in which 1 μl of anticoagulated blood were used as the template, showed the sensitivities of 98.1% for Pf, 92.1% for non-Pf, and the specificities of 98.1% for Pf, 100% for non-Pf. The prevalences of P. falciparum, P. malariae and P. ovale in the surveyed area were 52.4, 25.3 and 10.6%, respectively, indicating high prevalence of asymptomatic carriers in endemic areas in Zambia. We have developed new field-applicable malaria diagnostic tests. The malaria CZC-LAMPs showed high sensitivity and specificity to both P. falciparum and non-P. falciparum. These malaria CZC-LAMPs provide new means for rapid, sensitive and reliable point-of-care diagnosis for low-density malaria infections, and are expected to help update current knowledge of malaria epidemiology, and can contribute to the elimination of malaria from endemic areas.

  18. Evaluation of twenty-two rapid antigen detection tests in the diagnosis of Equine Influenza caused by viruses of H3N8 subtype.

    PubMed

    Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Gildea, Sarah; Cullinane, Ann

    2016-03-01

    Equine influenza (EI) is a highly contagious disease caused by viruses of the H3N8 subtype. The rapid diagnosis of EI is essential to reduce the disease spread. Many rapid antigen detection (RAD) tests for diagnosing human influenza are available, but their ability to diagnose EI has not been systematically evaluated. The aim of this study was to compare the performance of 22 RAD tests in the diagnosis of EI. The 22 RAD tests were performed on fivefold serial dilutions of EI virus to determine their detection limits. The four most sensitive RAD tests (ImmunoAce Flu, BD Flu examan, Quick chaser Flu A, B and ESPLINE Influenza A&B-N) were further evaluated using nasopharyngeal samples collected from experimentally infected and naturally infected horses. The results were compared to those obtained using molecular tests. The detection limits of the 22 RAD tests varied hugely. Even the four RAD tests showing the best sensitivity were 125-fold less sensitive than the molecular techniques. The duration of virus detection in the experimentally infected horses was shorter using the RAD tests than using the molecular techniques. The RAD tests detected between 27% and 73% of real-time RT-PCR-positive samples from naturally infected horses. The study demonstrated the importance of choosing the right RAD tests as only three of 22 were fit for diagnosing EI. It was also indicated that even RAD tests with the highest sensitivity serve only as an adjunct to molecular tests because of the potential for false-negative results. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  19. [What is hidden behind the Baking Tray Task? Study of sensibility and specificity in right-hemispheric stroke patients].

    PubMed

    Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa

    2015-12-16

    Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.

  20. Modulation of network pacemaker neurons by oxygen at the anaerobic threshold.

    PubMed

    Hill, Andrew A V; Simmers, John; Meyrand, Pierre; Massabuau, Jean-Charles

    2012-07-01

    Previous in vitro and in vivo studies showed that the frequency of rhythmic pyloric network activity in the lobster is modulated directly by oxygen partial pressure (PO(2)). We have extended these results by (1) increasing the period of exposure to low PO(2) and by (2) testing the sensitivity of the pyloric network to changes in PO(2) that are within the narrow range normally experienced by the lobster (1 to 6 kPa). We found that the pyloric network rhythm was indeed altered by changes in PO(2) within the range typically observed in vivo. Furthermore, a previous study showed that the lateral pyloric constrictor motor neuron (LP) contributes to the O(2) sensitivity of the pyloric network. Here, we expanded on this idea by testing the hypothesis that pyloric pacemaker neurons also contribute to pyloric O(2) sensitivity. A 2-h exposure to 1 kPa PO(2), which was twice the period used previously, decreased the frequency of an isolated group of pacemaker neurons, suggesting that changes in the rhythmogenic properties of these cells contribute to pyloric O(2) sensitivity during long-term near-anaerobic (anaerobic threshold, 0.7-1.2 kPa) conditions.

  1. Development of a highly sensitive lateral immunochromatographic assay for rapid detection of Vibrio parahaemolyticus.

    PubMed

    Liu, Xinfeng; Guan, Yuyao; Cheng, Shiliang; Huang, Yidan; Yan, Qin; Zhang, Jun; Huang, Guanjun; Zheng, Jian; Liu, Tianqiang

    2016-12-01

    Vibrio parahaemolyticus is widely present in brackish water all over the world, causing infections in certain aquatic animals. It is also a foodborne pathogen that causes diarrhea in humans. The aim of this study is to develop an immunochromatographic lateral flow assay (LFA) for rapid detection of V. parahaemolyticus in both aquatic products and human feces of diarrheal patients. Two monoclonal antibody (MAb) pairs, GA1a-IC9 and IC9-KB4c, were developed and proven to be highly specific and sensitive to V. parahaemolyticus. Based on the two MAb pairs, two types of LFA strips were prepared. Their testing limits for V. parahaemolyticus culture were both 1.2×10 3 CFU/ml. The diagnostic sensitivities and specificities were both 100% for the 32 tested microbial species, including 6 Vibrio species. Subsequently, the LFA strips were used to test Whiteleg shrimps and human feces. The type II strip showed a higher diagnostic sensitivity. Its sensitivity and specificity for hepatopancreas and fecal samples from 13 Whiteleg shrimps and fecal samples from 146 human diarrheal patients were all 100%. In conclusion, our homemade type II LFA is a very promising testing device for rapid and convenient detection of V. parahaemolyticus infection not only in aquatic animals, but also in human diarrheal patients. This sensitive immunochromtographic LFA allows rapid detection of V. parahaemolyticus without requirement of culture enrichment. Copyright © 2016. Published by Elsevier B.V.

  2. Angle performance on optima MDxt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David, Jonathan; Kamenitsa, Dennis

    2012-11-06

    Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightlymore » tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).« less

  3. Differential Expression of Ethanol-Induced Hypothermia in Adolescent and Adult Rats Induced by Pretest Familiarization to the Handling/Injection Procedure

    PubMed Central

    Ristuccia, Robert C.; Hernandez, Michael; Wilmouth, Carrie E.; Spear, Linda P.

    2007-01-01

    Background Previous work examining ethanol’s autonomic effects has found contrasting patterns of age-related differences in ethanol-induced hypothermia between adolescent and adult rats. Most studies have found adolescents to be less sensitive than adults to this effect, although other work has indicated that adolescents may be more sensitive than adults under certain testing conditions. To test the hypothesis that adolescents show more ethanol hypothermia than adults when the amount of disruption induced by the test procedures is low, but less hypothermia when the experimental perturbation is greater, the present study examined the consequences of manipulating the amount of perturbation at the time of testing on ethanol-induced hypothermia in adolescent and adult rats. Methods The amount of test disruption was manipulated by administering ethanol through a chronically indwelling gastric cannula (low perturbation) versus via intragastric intubation (higher perturbation) in Experiment 1 or by either familiarizing animals to the handling and injection procedure for several days pretest or leaving them unmanipulated before testing in Experiment 2. Results The results showed that the handling manipulation, but not the use of gastric cannulae, altered the expression of ethanol-induced hypothermia differentially across age. When using a familiarization protocol sufficient to reduce the corticosterone response to the handling and injection procedure associated with testing, adolescents showed greater hypothermia than adults. In contrast, the opposite pattern of age differences in hypothermia was evident in animals that were not manipulated before the test day. Surprisingly, however, this difference across testing circumstances was driven by a marked reduction in hypothermia among adults who had been handled before testing, with handling having relatively little impact on ethanol hypothermia among adolescents. Conclusions Observed differences between adolescents and adults in the autonomic consequences of ethanol were dramatically influenced by whether animals were familiarized with the handling/injection process before testing. Under these circumstances, adolescents were less susceptible than adults to the impact of experimental perturbation on ethanol-induced hypothermia. These findings suggest that seemingly innocuous aspects of experimental design can influence conclusions reached on ontogenetic differences in sensitivity to ethanol, at least when indexed by ethanol-induced hypothermia. PMID:17374036

  4. Differential expression of ethanol-induced hypothermia in adolescent and adult rats induced by pretest familiarization to the handling/injection procedure.

    PubMed

    Ristuccia, Robert C; Hernandez, Michael; Wilmouth, Carrie E; Spear, Linda P

    2007-04-01

    Previous work examining ethanol's autonomic effects has found contrasting patterns of age-related differences in ethanol-induced hypothermia between adolescent and adult rats. Most studies have found adolescents to be less sensitive than adults to this effect, although other work has indicated that adolescents may be more sensitive than adults under certain testing conditions. To test the hypothesis that adolescents show more ethanol hypothermia than adults when the amount of disruption induced by the test procedures is low, but less hypothermia when the experimental perturbation is greater, the present study examined the consequences of manipulating the amount of perturbation at the time of testing on ethanol-induced hypothermia in adolescent and adult rats. The amount of test disruption was manipulated by administering ethanol through a chronically indwelling gastric cannula (low perturbation) versus via intragastric intubation (higher perturbation) in Experiment 1 or by either familiarizing animals to the handling and injection procedure for several days pretest or leaving them unmanipulated before testing in Experiment 2. The results showed that the handling manipulation, but not the use of gastric cannulae, altered the expression of ethanol-induced hypothermia differentially across age. When using a familiarization protocol sufficient to reduce the corticosterone response to the handling and injection procedure associated with testing, adolescents showed greater hypothermia than adults. In contrast, the opposite pattern of age differences in hypothermia was evident in animals that were not manipulated before the test day. Surprisingly, however, this difference across testing circumstances was driven by a marked reduction in hypothermia among adults who had been handled before testing, with handling having relatively little impact on ethanol hypothermia among adolescents. Observed differences between adolescents and adults in the autonomic consequences of ethanol were dramatically influenced by whether animals were familiarized with the handling/injection process before testing. Under these circumstances, adolescents were less susceptible than adults to the impact of experimental perturbation on ethanol-induced hypothermia. These findings suggest that seemingly innocuous aspects of experimental design can influence conclusions reached on ontogenetic differences in sensitivity to ethanol, at least when indexed by ethanol-induced hypothermia.

  5. Multicenter clinical trial on a permanent hair dye containing paratoluenediamine.

    PubMed

    Foti, Caterina; Balato, Nicola; Cristaudo, Antonio; Patruno, Cataldo; Pigatto, Paolo; Ambrifi, Marina; Bufano, Tamara; Damiani, Giovanni; De Rocco, Mariagrazia; Diani, Marco; Napolitano, Maddalena; Romita, Paolo

    2018-08-01

    Adverse reactions to hair dyes are frequent and usually caused by sensitization to paraphenylenediamine (PPD). The aim of the study was to evaluate the tolerability of a PPD-free permanent hair dye (Shine On, BioNike, Milan, Italy) containing paratoluenediamine (PTD) in a group of subjects sensitized to PPD. The trial, which carried out at four dermatology centers, included subjects sensitized to PPD that turned out negative to patch testing to PTD. The subjects underwent to an open test consisting in the application of two hair dye colors of the product under examination. Finally, subjects who were negative upon the open test were offered to undergo the usage test with the dye, with dermatological evaluations carried out 48 and 96 hours after product application. Sixty subjects were enrolled. They underwent the open test with two shades of dyes: "color 1 - black," the dye color with the highest concentration of color intermediates, and "color 7.3 - golden blonde," the dye color with the highest number of chemically different color intermediates. No reactions occurred with "color 7.3 - golden blonde," while 3 cases (3 out of 60) showed erythema and edema reactions to color 1. The hair dye usage test was negative for all the 21 subjects that were enrolled. The hair dye evaluated in this study (Shine On, BioNike) can be a valid alternative for subjects sensitized to PPD.

  6. A 3-Year Study of Predictive Factors for Positive and Negative Appendicectomies.

    PubMed

    Chang, Dwayne T S; Maluda, Melissa; Lee, Lisa; Premaratne, Chandrasiri; Khamhing, Srisongham

    2018-03-06

    Early and accurate identification or exclusion of acute appendicitis is the key to avoid the morbidity of delayed treatment for true appendicitis or unnecessary appendicectomy, respectively. We aim (i) to identify potential predictive factors for positive and negative appendicectomies; and (ii) to analyse the use of ultrasound scans (US) and computed tomography (CT) scans for acute appendicitis. All appendicectomies that took place at our hospital from the 1st of January 2013 to the 31st of December 2015 were retrospectively recorded. Test results of potential predictive factors of acute appendicitis were recorded. Statistical analysis was performed using Fisher exact test, logistic regression analysis, sensitivity, specificity, and positive and negative predictive values calculation. 208 patients were included in this study. 184 patients had histologically proven acute appendicitis. The other 24 patients had either nonappendicitis pathology or normal appendix. Logistic regression analysis showed statistically significant associations between appendicitis and white cell count, neutrophil count, C-reactive protein, and bilirubin. Neutrophil count was the test with the highest sensitivity and negative predictive values, whereas bilirubin was the test with the highest specificity and positive predictive values (PPV). US and CT scans had high sensitivity and PPV for diagnosing appendicitis. No single test was sufficient to diagnose or exclude acute appendicitis by itself. Combining tests with high sensitivity (abnormal neutrophil count, and US and CT scans) and high specificity (raised bilirubin) may predict acute appendicitis more accurately.

  7. [Sensitivity and specificity of prick skin test with two concentrations of standardized extract of Culex quinquefasciatus in allergic children].

    PubMed

    Castro-Almarales, Raúl Lázaro; Álvarez-Castelló, Mirta; Ronquillo-Díaz, Mercedes; Rodríguez-Canosa, José S; González-León, Mayda; Navarro-Viltre, Bárbara I; Betancourt-Mesia, Daniel; Enríquez-Domínguez, Irene; Reyes-Zamora, Mary Carmen; Oliva-Díaz, Yunia; Mateo-Morejón, Maytee; Labrada-Rosado, Alexis

    2016-01-01

    Diagnostic options for immune reactions to mosquito bites are limited. In Cuba, IgE-mediated reactions are frequently related to Culex quinquefasciatus bite. To determine the sensitivity and specificity of skin prick test with two doses of standardized extract in nitrogen protein units (PNU of Culex quinquefasciatus (BIOCEN, Cuba). An analytical study was conducted on 100 children between 2 and 15 years old. Fifty atopic patients with a history of allergy to mosquito bite and positive specific serum IgE Culex quinquefasciatus and fifty atopic patients without a history of allergy to mosquito bite and negative specific serum IgE to Culex quinquefasciatus. Skin prick tests (SPT) were performed by duplicates on the forearms of the patients. Investigated doses were 100 PNU/mL and 10 PNU/mL. SPT with the highest concentration obtained a mean wheal size of 22.09 mm2 and for lower doses of 8.09 mm2, a statistically significant difference (p=0.001, Student's t test). Positive skin test correlated in 100% of patients with the presence of specific IgE. Testing with both doses showed a 94% of specificity and 88% of sensitivity. The diagnostic accuracy of SPT using both doses of standardized extract was similar, which justifies its use for diagnosis of sensitization to Culex quinquefasciatus in patients with symptoms of allergy to mosquito bite.

  8. High sensitive detection of copper II ions using D-penicillamine-coated gold nanorods based on localized surface plasmon resonance

    NASA Astrophysics Data System (ADS)

    Hong, Yoochan; Jo, Seongjae; Park, Joohyung; Park, Jinsung; Yang, Jaemoon

    2018-05-01

    In this paper, we describe the development of a nanoplasmonic biosensor based on the localized surface plasmon resonance (LSPR) effect that enables a sensitive and selective recognition of copper II ions. First, we fabricated the nanoplasmonics as LSPR substrates using gold nanorods (GNR) and the nano-adsorption method. The LSPR sensitivity of the nanoplasmonics was evaluated using various solvents with different refractive indexes. Subsequently, D-penicillamine (DPA)—a chelating agent of copper II ions—was conjugated to the surface of the GNR. The limit of detection (LOD) for the DPA-conjugated nanoplasmonics was 100 pM. Furthermore, selectivity tests were conducted using various divalent cations, and sensitivity tests were conducted on the nanoplasmonics under blood-like environments. Finally, the developed nanoplasmonic biosensor based on GNR shows great potential for the effective recognition of copper II ions, even in human blood conditions.

  9. High sensitive detection of copper II ions using D-penicillamine-coated gold nanorods based on localized surface plasmon resonance.

    PubMed

    Hong, Yoochan; Jo, Seongjae; Park, Joohyung; Park, Jinsung; Yang, Jaemoon

    2018-05-25

    In this paper, we describe the development of a nanoplasmonic biosensor based on the localized surface plasmon resonance (LSPR) effect that enables a sensitive and selective recognition of copper II ions. First, we fabricated the nanoplasmonics as LSPR substrates using gold nanorods (GNR) and the nano-adsorption method. The LSPR sensitivity of the nanoplasmonics was evaluated using various solvents with different refractive indexes. Subsequently, D-penicillamine (DPA)-a chelating agent of copper II ions-was conjugated to the surface of the GNR. The limit of detection (LOD) for the DPA-conjugated nanoplasmonics was 100 pM. Furthermore, selectivity tests were conducted using various divalent cations, and sensitivity tests were conducted on the nanoplasmonics under blood-like environments. Finally, the developed nanoplasmonic biosensor based on GNR shows great potential for the effective recognition of copper II ions, even in human blood conditions.

  10. Sensitivity analysis of a sound absorption model with correlated inputs

    NASA Astrophysics Data System (ADS)

    Chai, W.; Christen, J.-L.; Zine, A.-M.; Ichchou, M.

    2017-04-01

    Sound absorption in porous media is a complex phenomenon, which is usually addressed with homogenized models, depending on macroscopic parameters. Since these parameters emerge from the structure at microscopic scale, they may be correlated. This paper deals with sensitivity analysis methods of a sound absorption model with correlated inputs. Specifically, the Johnson-Champoux-Allard model (JCA) is chosen as the objective model with correlation effects generated by a secondary micro-macro semi-empirical model. To deal with this case, a relatively new sensitivity analysis method Fourier Amplitude Sensitivity Test with Correlation design (FASTC), based on Iman's transform, is taken into application. This method requires a priori information such as variables' marginal distribution functions and their correlation matrix. The results are compared to the Correlation Ratio Method (CRM) for reference and validation. The distribution of the macroscopic variables arising from the microstructure, as well as their correlation matrix are studied. Finally the results of tests shows that the correlation has a very important impact on the results of sensitivity analysis. Assessment of correlation strength among input variables on the sensitivity analysis is also achieved.

  11. Antimicrobial Sensitivity of Avibacterium paragallinarum Isolates from Four Latin American Countries.

    PubMed

    Luna-Galaz, G A; Morales-Erasto, V; Peñuelas-Rivas, C G; Blackall, P J; Soriano-Vargas, E

    2016-09-01

    The antimicrobial sensitivity of 11 reference strains and 66 Avibacterium paragallinarum isolates from four Latin American countries was investigated. All 11 reference strains were sensitive to amoxicillin-clavulanic acid, ampicillin, fosfomycin, gentamicin, kanamycin, neomycin, penicillin, tetracycline, and trimethoprim-sulfamethoxazole. The 11 reference strains were all resistant to lincomycin. All isolates (100%) from Mexico, Panama, and Peru were sensitive to amoxicillin-clavulanic acid, ampicillin, and fosfomycin. The Ecuadorian isolates showed some level of resistance to all 16 agents tested. The Ecuadorian isolates were significantly more sensitive to erythromycin, lincomycin, and streptomycin, and significantly more resistant to gentamicin, kanamycin, penicillin, and tetracycline, than the Mexican isolates. A total of 57.5% (38/66) of tested isolates were multi-drug resistant (MDR), with 16 MDR patterns detected in 88.4% (23/26) of the antimicrobial-resistant isolates from Ecuador, and 8 MDR patterns detected in 42.8% (15/35) of the antimicrobial-resistant isolates from Mexico. In conclusion, the variation in antimicrobial sensitivity patterns between isolates from Ecuador and Mexico emphasizes the importance of active, ongoing monitoring of A. paragallinarum isolates.

  12. Testing of stack-unit/aquifer sensitivity analysis using contaminant plume distribution in the subsurface of Savannah River Site, South Carolina, USA

    USGS Publications Warehouse

    Rine, J.M.; Shafer, J.M.; Covington, E.; Berg, R.C.

    2006-01-01

    Published information on the correlation and field-testing of the technique of stack-unit/aquifer sensitivity mapping with documented subsurface contaminant plumes is rare. The inherent characteristic of stack-unit mapping, which makes it a superior technique to other analyses that amalgamate data, is the ability to deconstruct the sensitivity analysis on a unit-by-unit basis. An aquifer sensitivity map, delineating the relative sensitivity of the Crouch Branch aquifer of the Administrative/Manufacturing Area (A/M) at the Savannah River Site (SRS) in South Carolina, USA, incorporates six hydrostratigraphic units, surface soil units, and relevant hydrologic data. When this sensitivity map is compared with the distribution of the contaminant tetrachloroethylene (PCE), PCE is present within the Crouch Branch aquifer within an area classified as highly sensitive, even though the PCE was primarily released on the ground surface within areas classified with low aquifer sensitivity. This phenomenon is explained through analysis of the aquifer sensitivity map, the groundwater potentiometric surface maps, and the plume distributions within the area on a unit-by- unit basis. The results of this correlation show how the paths of the PCE plume are influenced by both the geology and the groundwater flow. ?? Springer-Verlag 2006.

  13. Species-specific diagnostic assays for Bonamia ostreae and B. exitiosa in European flat oyster Ostrea edulis: conventional, real-time and multiplex PCR.

    PubMed

    Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira

    2013-05-27

    Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.

  14. Age and sex differences in the taste sensitivity of young adult, young-old and old-old Japanese.

    PubMed

    Yoshinaka, Masaki; Ikebe, Kazunori; Uota, Masahiro; Ogawa, Taiji; Okada, Tadashi; Inomata, Chisato; Takeshita, Hajime; Mihara, Yusuke; Gondo, Yasuyuki; Masui, Yukie; Kamide, Kei; Arai, Yasumichi; Takahashi, Ryutaro; Maeda, Yoshinobu

    2016-12-01

    The present study examined sex and age differences in taste sensitivity among young adult, young-old and old-old Japanese. Participants were divided into three groups comprising 477 men and 519 women in the young-old group (aged 69-71 years), 449 men and 500 women in the old-old group (aged 79-81 years), and 35 men and 35 women in the young adult group (aged 24-32 years). Recognition thresholds for the four basic tastes were measured using the 1-mL whole mouth gustatory test, in which taste solutions of the four basic tastes were tested in five concentrations. Young adults showed significantly lower recognition thresholds than the young-old group, and the young-old group showed significantly lower recognition thresholds than the old-old group. Among the young-old and old-old groups, women showed significantly lower recognition thresholds than males for sour, salty and bitter tastes, but there was no sex difference in the sweet taste threshold between the two groups. The present study confirmed that there are age and sex differences in taste sensitivity for the four basic tastes among young adult, young-old, and old-old Japanese, and that the sensitivity of sweet taste is more robust than the other tastes. Geriatr Gerontol Int 2016; 16: 1281-1288. © 2015 Japan Geriatrics Society.

  15. Field evaluation of a malaria rapid diagnostic test (ICT Pf).

    PubMed

    Moonasar, Devanand; Goga, Ameena E; Kruger, Philip S; La Cock, Christine; Maharaj, Rajendra; Frean, John; Chandramohan, Daniel

    2009-11-01

    Malaria rapid diagnostic tests (MRDTs) are quick and easy to perform and useful for diagnosing malaria in primary health care settings. In South Africa most malaria infections are due to Plasmodium falciparurrm, and HRPII-based MRDTs have been used since 2001. Previous studies in Africa showed variability in sensitivity and specificity of HRPII-based MRDTs; hence, we conducted a field evaluation in Limpopo province to determine the accuracy of the MRDT currently used in public sector clinics and hospitals. A cross-sectional observational study was conducted to determine the sensitivity and specificity of an ICT Pf MRDT. We tested 405 patients with fever with ICT Pf MRDT and compared the results with blood film microscopy (the gold standard). RESULTS. The overall sensitivity of the ICT Pf MRDT was 99.48% (95% confidence interval (CI) 96.17-100%), while specificity was 96.26% (95% CI 94.7-100%). The positive predictive value of the test was 98.48 (99% CI 98.41-100%), and the negative predictive value was 99.52% (95% CI 96.47-100%). The ICT Pf MRDT is an appropriate test to use in the field in South Africa where laboratory facilities are not available. It has a high degree of sensitivity and acceptable level of specificity in accordance with the World Health Organization criteria. However, sensitivity of MRDT at low levels of parasitaemia (<100 parasites/microl of blood) in field conditions must still be established.

  16. Phytotoxicity of floodplain soils contaminated with trace metals along the Clark Fork River, Grant-Kohrs Ranch National Historic Site, Deer Lodge, Montana, USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rader, B.R.; Nimmo, D.W.R.; Chapman, P.L.

    1997-07-01

    Concentrations of metals in sediments and soils deposited along the floodplain of the Clark Fork River, within the Grant-Kohrs Ranch National Historic Site, Deer Lodge, Montana, USA, have exceeded maximum background concentrations in the United States for most metals tested. As a result of mining and smelting activities, portions of the Deer Lodge Valley, including the Grant-Kohrs Ranch, have received National Priority List Designation under the Comprehensive Environmental Response, Compensation and Liability Act. Using a series of plant germination tests, pH measurements, and metal analyses, this study investigated the toxicity of soils from floodplain slicken areas, bare spots devoid ofmore » vegetation, along the Clark Fork River. The slicken soils collected from the Grant-Kohrs Ranch were toxic to all four plant species tested. The most sensitive endpoint in the germination tests was root length and the least sensitive was emergence. Considering emergence, the most sensitive species was the resident grass species Agrostis gigantea. The sensitivities were reversed when root lengths were examined, with Echinochloa crusgalli showing the greatest sensitivity. Both elevated concentrations of metals and low pH were necessary to produce an acutely phytotoxic response in laboratory seed germination tests using slicken soils. Moreover, pH values on the Grant-Kohrs Ranch appear to be a better predictor of acutely phytotoxic conditions than total metal levels.« less

  17. Effects of postnatal growth restriction and subsequent catch-up growth on neurodevelopment and glucose homeostasis in rats.

    PubMed

    Alexeev, Erica E; Lönnerdal, Bo; Griffin, Ian J

    2015-06-05

    There is increasing evidence that poor growth of preterm infants is a risk factor for poor long-term development, while the effects of early postnatal growth restriction are not well known. We utilized a rat model to examine the consequences of different patterns of postnatal growth and hypothesized that early growth failure leads to impaired development and insulin resistance. Rat pups were separated at birth into normal (N, n = 10) or restricted intake (R, n = 16) litters. At d11, R pups were re-randomized into litters of 6 (R-6), 10 (R-10) or 16 (R-16) pups/dam. N pups remained in litters of 10 pups/dam (N-10). Memory and learning were examined through T-maze test. Insulin sensitivity was measured by i.p. insulin tolerance test and glucose tolerance test. By d10, N pups weighed 20% more than R pups (p < 0.001). By d15, the R-6 group caught up to the N-10 group in weight, the R-10 group showed partial catch-up growth and the R-16 group showed no catch-up growth. All R groups showed poorer scores in developmental testing when compared with the N-10 group during T-Maze test (p < 0.05). Although R-16 were more insulin sensitive than R-6 and R-10, all R groups were more glucose tolerant than N-10. In rats, differences in postnatal growth restriction leads to changes in development and in insulin sensitivity. These results may contribute to better elucidating the causes of poor developmental outcomes in human preterm infants.

  18. Assessment of Protective Effect of Some Modern Agrochemicals against Ozone-Induced Stress in Sensitive Clover and Tobacco Cultivars.

    PubMed

    Blum, Oleg; Didyk, Nataliya; Pavluchenko, Nataliya; Godzik, Barbara

    2011-01-01

    Some modern agrochemicals with antioxidant potential were tested for their protective effect against ozone injury using clover and tobacco ozone-sensitive cultivars as model plants subjected to ambient ozone at two sites (Kyiv city in Ukraine and Szarów village in Poland). All used agrochemicals showed partial protective effects against ozone injury on clover and tobacco. Conducted studies confirmed the effectiveness of modern fungicides belonging to strobilurin group as protectants of sensitive crops against ozone damage. The effectiveness of new growth regulators "Emistym C" and "Agrostymulin" was showed for the first time. Out of the studied agrochemicals, fungicide "Strobi" and natural growth regulator "Emistym C" demonstrated the best protective effects. These agrochemicals present promise for further studies of their possible utilization for enhancement of ozone tolerance of sensitive crops.

  19. Behavioral metabolomics analysis identifies novel neurochemical signatures in methamphetamine sensitization

    PubMed Central

    Adkins, Daniel E.; McClay, Joseph L.; Vunck, Sarah A.; Batman, Angela M.; Vann, Robert E.; Clark, Shaunna L.; Souza, Renan P.; Crowley, James J.; Sullivan, Patrick F.; van den Oord, Edwin J.C.G.; Beardsley, Patrick M.

    2014-01-01

    Behavioral sensitization has been widely studied in animal models and is theorized to reflect neural modifications associated with human psychostimulant addiction. While the mesolimbic dopaminergic pathway is known to play a role, the neurochemical mechanisms underlying behavioral sensitization remain incompletely understood. In the present study, we conducted the first metabolomics analysis to globally characterize neurochemical differences associated with behavioral sensitization. Methamphetamine-induced sensitization measures were generated by statistically modeling longitudinal activity data for eight inbred strains of mice. Subsequent to behavioral testing, nontargeted liquid and gas chromatography-mass spectrometry profiling was performed on 48 brain samples, yielding 301 metabolite levels per sample after quality control. Association testing between metabolite levels and three primary dimensions of behavioral sensitization (total distance, stereotypy and margin time) showed four robust, significant associations at a stringent metabolome-wide significance threshold (false discovery rate < 0.05). Results implicated homocarnosine, a dipeptide of GABA and histidine, in total distance sensitization, GABA metabolite 4-guanidinobutanoate and pantothenate in stereotypy sensitization, and myo-inositol in margin time sensitization. Secondary analyses indicated that these associations were independent of concurrent methamphetamine levels and, with the exception of the myo-inositol association, suggest a mechanism whereby strain-based genetic variation produces specific baseline neurochemical differences that substantially influence the magnitude of MA-induced sensitization. These findings demonstrate the utility of mouse metabolomics for identifying novel biomarkers, and developing more comprehensive neurochemical models, of psychostimulant sensitization. PMID:24034544

  20. [Laboratory diagnosis of auto-immune hemolytic anemia: characteristics of the manual direct test of Polybrene].

    PubMed

    Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A

    1998-01-01

    The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.

  1. Oxidative tryptophan modification by terpene- and squalene-hydroperoxides and a possible link to cross-reactions in diagnostic tests.

    PubMed

    Natsch, Andreas; Emter, Roger; Badertscher, Remo P; Brunner, Gerhard; Granier, Thierry; Kern, Susanne; Ellis, Graham

    2015-06-15

    Hydroperoxides can act as specific haptens and oxidatively modify proteins. Terpene hydroperoxides trigger unusually high frequencies of positive skin reactions in human patients if tested at high concentrations. It is unknown whether this is due to specific hapten formation. Here, we show that both terpene hydroperoxides and the endogenous hydroperoxide formed from squalene can oxidatively modify tryptophan. Oxidative modifications of Trp were recently postulated to explain cross-sensitization between unrelated photosensitizers. Current observations may extend this hypothesis: Oxidative events triggered by endogenous hydroperoxides and hydroperoxides/oxidants derived from xenobiotics might lead to a sensitized state detected by patch tests with high concentrations of hydroperoxides.

  2. Design and fabrication of highly sensitive and stable biochip for glucose biosensing

    NASA Astrophysics Data System (ADS)

    Lu, Shi-Yu; Lu, Yao; Jin, Meng; Bao, Shu-Juan; Li, Wan-Yun; Yu, Ling

    2017-11-01

    Common producing steps for test strips is complex and fussy. In this work, we proposed a feasible binder-free test strips fabrication method to directly grow enzyme/manganese phosphate nanosheets hybrids on the screen-print electrodes (SPE). Combined with microfluidic packaging technology, the ready-made portable electrochemical biochip shows a wider linear range (1-40 mM, R2 = 0.9998) and excellent stability (maintained 98% response current after 20 days store and retained 75% response current after continuous 30 days determination) for the detection of glucose. Compared with commercial test strips, the biochip exhibits excellent sensitivity, stability and accuracy, which is indicative of its potential application in real samples.

  3. The fish embryo toxicity test as a replacement for the larval growth and survival test: A comparison of test sensitivity and identification of alternative endpoints in zebrafish and fathead minnows.

    PubMed

    Jeffries, Marlo K Sellin; Stultz, Amy E; Smith, Austin W; Stephens, Dane A; Rawlings, Jane M; Belanger, Scott E; Oris, James T

    2015-06-01

    The fish embryo toxicity (FET) test has been proposed as an alternative to the larval growth and survival (LGS) test. The objectives of the present study were to evaluate the sensitivity of the FET and LGS tests in fathead minnows (Pimephales promelas) and zebrafish (Danio rerio) and to determine if the inclusion of sublethal metrics as test endpoints could enhance test utility. In both species, LGS and FET tests were conducted using 2 simulated effluents. A comparison of median lethal concentrations determined via each test revealed significant differences between test types; however, it could not be determined which test was the least and/or most sensitive. At the conclusion of each test, developmental abnormalities and the expression of genes related to growth and toxicity were evaluated. Fathead minnows and zebrafish exposed to mock municipal wastewater-treatment plant effluent in a FET test experienced an increased incidence of pericardial edema and significant alterations in the expression of genes including insulin-like growth factors 1 and 2, heat shock protein 70, and cytochrome P4501A, suggesting that the inclusion of these endpoints could enhance test utility. The results not only show the utility of the fathead minnow FET test as a replacement for the LGS test but also provide evidence that inclusion of additional endpoints could improve the predictive power of the FET test. © 2015 SETAC.

  4. Discussions On Worst-Case Test Condition For Single Event Burnout

    NASA Astrophysics Data System (ADS)

    Liu, Sandra; Zafrani, Max; Sherman, Phillip

    2011-10-01

    This paper discusses the failure characteristics of single- event burnout (SEB) on power MOSFETs based on analyzing the quasi-stationary avalanche simulation curves. The analyses show the worst-case test condition for SEB would be using the ion that has the highest mass that would result in the highest transient current due to charge deposition and displacement damage. The analyses also show it is possible to build power MOSFETs that will not exhibit SEB even when tested with the heaviest ion, which have been verified by heavy ion test data on SEB sensitive and SEB immune devices.

  5. Verbal priming and taste sensitivity make moral transgressions gross.

    PubMed

    Herz, Rachel S

    2014-02-01

    The aims of the present study were to assess whether: (a) visceral and moral disgust share a common oral origin (taste); (b) moral transgressions that are also viscerally involving are evaluated accordingly as a function of individual differences in taste sensitivity; (c) verbal priming interacts with taste sensitivity to alter how disgust is experienced in moral transgressions; and (d) whether gender moderates these effects. Standard tests of disgust sensitivity, a questionnaire developed for this research assessing different types of moral transgressions (nonvisceral, implied-visceral, visceral) with the terms "angry" and "grossed-out," and a taste sensitivity test of 6-n-propylthiouracil (PROP) were administered to 102 participants. Results confirmed past findings that the more sensitive to PROP a participant was the more disgusted they were by visceral, but not moral, disgust elicitors. Importantly, the findings newly revealed that taste sensitivity had no bearing on evaluations of moral transgressions, regardless of their visceral nature, when "angry" was the emotion primed. However, when "grossed-out" was primed for evaluating moral violations, the more intense PROP tasted to a participant the more "grossed-out" they were by all transgressions. Women were generally more disgust sensitive and morally condemning than men, but disgust test, transgression type, and priming scale modulated these effects. The present findings support the proposition that moral and visceral disgust do not share a common oral origin, but show that linguistic priming can transform a moral transgression into a viscerally repulsive event and that susceptibility to this priming varies as a function of an individual's sensitivity to the origins of visceral disgust-bitter taste.

  6. Age-related changes in perception of movement in driving scenes.

    PubMed

    Lacherez, Philippe; Turner, Laura; Lester, Robert; Burns, Zoe; Wood, Joanne M

    2014-07-01

    Age-related changes in motion sensitivity have been found to relate to reductions in various indices of driving performance and safety. The aim of this study was to investigate the basis of this relationship in terms of determining which aspects of motion perception are most relevant to driving. Participants included 61 regular drivers (age range 22-87 years). Visual performance was measured binocularly. Measures included visual acuity, contrast sensitivity and motion sensitivity assessed using four different approaches: (1) threshold minimum drift rate for a drifting Gabor patch, (2) Dmin from a random dot display, (3) threshold coherence from a random dot display, and (4) threshold drift rate for a second-order (contrast modulated) sinusoidal grating. Participants then completed the Hazard Perception Test (HPT) in which they were required to identify moving hazards in videos of real driving scenes, and also a Direction of Heading task (DOH) in which they identified deviations from normal lane keeping in brief videos of driving filmed from the interior of a vehicle. In bivariate correlation analyses, all motion sensitivity measures significantly declined with age. Motion coherence thresholds, and minimum drift rate threshold for the first-order stimulus (Gabor patch) both significantly predicted HPT performance even after controlling for age, visual acuity and contrast sensitivity. Bootstrap mediation analysis showed that individual differences in DOH accuracy partly explained these relationships, where those individuals with poorer motion sensitivity on the coherence and Gabor tests showed decreased ability to perceive deviations in motion in the driving videos, which related in turn to their ability to detect the moving hazards. The ability to detect subtle movements in the driving environment (as determined by the DOH task) may be an important contributor to effective hazard perception, and is associated with age, and an individuals' performance on tests of motion sensitivity. The locus of the processing deficits appears to lie in first-order, rather than second-order motion pathways. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  7. Performance of a HRP-2/pLDH based rapid diagnostic test at the Bangladesh-India-Myanmar border areas for diagnosis of clinical malaria

    PubMed Central

    2013-01-01

    Background The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Parascreen® Pan/Pf) in a laboratory setting utilizing clinical samples obtained from the field. Methods Whole blood samples were obtained from febrile patients referred for malaria diagnosis by clinicians from two different Upazila Health Complexes (UHCs) located near the Bangladesh-India and Bangladesh-Myanmar border where malaria is endemic. RDT was performed on archived samples and sensitivity and specificity evaluated with expert microscopy (EM) and quantitative PCR (qPCR). Results A total of 327 clinical samples were made available for the study, of which 153 were Plasmodium falciparum-positive and 54 were Plasmodium vivax-positive. In comparison with EM, for P. falciparum malaria, the RDT had sensitivity: 96.0% (95% CI, 91.2-98.3) and specificity: 98.2% (95% CI, 94.6-99.5) and for P. vivax, sensitivity: 90.7% (95% CI, 78.9-96.5) and specificity: 98.9% (95% CI, 96.5-99.7). Comparison with qPCR showed, for P. falciparum malaria, sensitivity: 95.4% (95% CI, 90.5-98.0) and specificity: 98.8% (95% CI, 95.4-99.7) and for P. vivax malaria, sensitivity: 89.0% (95% CI,77.0-95.4) and specificity: 98.8% (95% CI, 96.5-99.7). Sensitivity varied according to different parasitaemia for falciparum and vivax malaria diagnosis. Conclusion Parascreen® Pan/Pf Rapid test for malaria showed acceptable sensitivity and specificity in border belt endemic areas of Bangladesh when compared with EM and qPCR. PMID:24172045

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrows, T.A.; Thoma, P.J.

    Two types of ion-mobility detectors were evaluated in both laboratory and field tests. Laboratory test results show that these detectors are highly sensitive to dynamite and pistol powder and have good false-alarm agent rejection. Field tests of these two detectors revealed that they would detect dynamite and Ball-C-Propellent in free air. However, neither of the ion-mobility detectors would detect these explosives if the explosives were concealed.

  9. Serpentine End Matching: A Test of Visual Perception

    Treesearch

    Bruce G. Hansen; Charles J. Gatchell

    1978-01-01

    In tests of gross perception of Serpentine end matched (Sem) joints in oak and cherry display panels, there were no significant differences between the number of times the non-Sem panels were chosen and the number of these selections that could be attributed to chance. Results of separate tests of sensitivity of perception of Sem joints showed that the most conspicuous...

  10. Stress Corrosion Cracking Behavior of Hardening-Treated 13Cr Stainless Steel

    NASA Astrophysics Data System (ADS)

    Niu, Li-Bin; Ishitake, Hisamitsu; Izumi, Sakae; Shiokawa, Kunio; Yamashita, Mitsuo; Sakai, Yoshihiro

    2018-03-01

    Stress corrosion cracking (SCC) behavior of the hardening-treated materials of 13Cr stainless steel was examined with SSRT tests and constant load tests. In the simulated geothermal water and even in the test water without addition of impurities, the hardening-treated materials showed a brittle intergranular fracture due to the sensitization, which was caused by the present hardening-treatments.

  11. Establishment of a nested-ASP-PCR method to determine the clarithromycin resistance of Helicobacter pylori.

    PubMed

    Luo, Xiao-Feng; Jiao, Jian-Hua; Zhang, Wen-Yue; Pu, Han-Ming; Qu, Bao-Jin; Yang, Bing-Ya; Hou, Min; Ji, Min-Jun

    2016-07-07

    To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23SrRNA gene in Helicobacter pylori (H. pylori) by nested-allele specific primer-polymerase chain reaction (nested-ASP-PCR). The gastric tissue and saliva samples from 99 patients with positive results of the rapid urease test (RUT) were collected. The nested-ASP-PCR method was carried out with the external primers and inner allele-specific primers corresponding to the reference strain and clinical strains. Thirty gastric tissue and saliva samples were tested to determine the sensitivity of nested-ASP-PCR and ASP-PCR methods. Then, clarithromycin resistance was detected for 99 clinical samples by using different methods, including nested-ASP-PCR, bacterial culture and disk diffusion. The nested-ASP-PCR method was successfully established to test the resistance mutation points 2142, 2143 and 2144 of the 23SrRNA gene of H. pylori. Among 30 samples of gastric tissue and saliva, the H. pylori detection rate of nested-ASP-PCR was 90% and 83.33%, while the detection rate of ASP-PCR was just 63% and 56.67%. Especially in the saliva samples, nested-ASP-PCR showed much higher sensitivity in H. pylori detection and resistance mutation rates than ASP-PCR. In the 99 RUT-positive gastric tissue and saliva samples, the H. pylori-positive detection rate by nested-ASP-PCR was 87 (87.88%) and 67 (67.68%), in which there were 30 wild-type and 57 mutated strains in gastric tissue and 22 wild-type and 45 mutated strains in saliva. Genotype analysis showed that three-points mixed mutations were quite common, but different resistant strains were present in gastric mucosa and saliva. Compared to the high sensitivity shown by nested-ASP-PCR, the positive detection of bacterial culture with gastric tissue samples was 50 cases, in which only 26 drug-resistant strains were found through analyzing minimum inhibitory zone of clarithromycin. The nested-ASP-PCR assay showed higher detection sensitivity than ASP-PCR and drug sensitivity testing, which could be performed to evaluate clarithromycin resistance of H. pylori.

  12. Establishment of a nested-ASP-PCR method to determine the clarithromycin resistance of Helicobacter pylori

    PubMed Central

    Luo, Xiao-Feng; Jiao, Jian-Hua; Zhang, Wen-Yue; Pu, Han-Ming; Qu, Bao-Jin; Yang, Bing-Ya; Hou, Min; Ji, Min-Jun

    2016-01-01

    AIM: To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23SrRNA gene in Helicobacter pylori (H. pylori) by nested-allele specific primer-polymerase chain reaction (nested-ASP-PCR). METHODS: The gastric tissue and saliva samples from 99 patients with positive results of the rapid urease test (RUT) were collected. The nested-ASP-PCR method was carried out with the external primers and inner allele-specific primers corresponding to the reference strain and clinical strains. Thirty gastric tissue and saliva samples were tested to determine the sensitivity of nested-ASP-PCR and ASP-PCR methods. Then, clarithromycin resistance was detected for 99 clinical samples by using different methods, including nested-ASP-PCR, bacterial culture and disk diffusion. RESULTS: The nested-ASP-PCR method was successfully established to test the resistance mutation points 2142, 2143 and 2144 of the 23SrRNA gene of H. pylori. Among 30 samples of gastric tissue and saliva, the H. pylori detection rate of nested-ASP-PCR was 90% and 83.33%, while the detection rate of ASP-PCR was just 63% and 56.67%. Especially in the saliva samples, nested-ASP-PCR showed much higher sensitivity in H. pylori detection and resistance mutation rates than ASP-PCR. In the 99 RUT-positive gastric tissue and saliva samples, the H. pylori-positive detection rate by nested-ASP-PCR was 87 (87.88%) and 67 (67.68%), in which there were 30 wild-type and 57 mutated strains in gastric tissue and 22 wild-type and 45 mutated strains in saliva. Genotype analysis showed that three-points mixed mutations were quite common, but different resistant strains were present in gastric mucosa and saliva. Compared to the high sensitivity shown by nested-ASP-PCR, the positive detection of bacterial culture with gastric tissue samples was 50 cases, in which only 26 drug-resistant strains were found through analyzing minimum inhibitory zone of clarithromycin. CONCLUSION: The nested-ASP-PCR assay showed higher detection sensitivity than ASP-PCR and drug sensitivity testing, which could be performed to evaluate clarithromycin resistance of H. pylori. PMID:27433095

  13. DESIGN OF MEDICAL RADIOMETER FRONT-END FOR IMPROVED PERFORMANCE

    PubMed Central

    Klemetsen, Ø.; Birkelund, Y.; Jacobsen, S. K.; Maccarini, P. F.; Stauffer, P. R.

    2011-01-01

    We have investigated the possibility of building a singleband Dicke radiometer that is inexpensive, small-sized, stable, highly sensitive, and which consists of readily available microwave components. The selected frequency band is at 3.25–3.75 GHz which provides a reasonable compromise between spatial resolution (antenna size) and sensing depth for radiometry applications in lossy tissue. Foreseen applications of the instrument are non-invasive temperature monitoring for breast cancer detection and temperature monitoring during heating. We have found off-the-shelf microwave components that are sufficiently small (< 5 mm × 5 mm) and which offer satisfactory overall sensitivity. Two different Dicke radiometers have been realized: one is a conventional design with the Dicke switch at the front-end to select either the antenna or noise reference channels for amplification. The second design places a matched pair of low noise amplifiers in front of the Dicke switch to reduce system noise figure. Numerical simulations were performed to test the design concepts before building prototype PCB front-end layouts of the radiometer. Both designs provide an overall power gain of approximately 50 dB over a 500 MHz bandwidth centered at 3.5 GHz. No stability problems were observed despite using triple-cascaded amplifier configurations to boost the thermal signals. The prototypes were tested for sensitivity after calibration in two different water baths. Experiments showed superior sensitivity (36% higher) when implementing the low noise amplifier before the Dicke switch (close to the antenna) compared to the other design with the Dicke switch in front. Radiometer performance was also tested in a multilayered phantom during alternating heating and radiometric reading. Empirical tests showed that for the configuration with Dicke switch first, the switch had to be locked in the reference position during application of microwave heating to avoid damage to the active components (amplifiers and power meter). For the configuration with a low noise amplifier up front, damage would occur to the active components of the radiometer if used in presence of the microwave heating antenna. Nevertheless, this design showed significantly improved sensitivity of measured temperatures and merits further investigation to determine methods of protecting the radiometer for amplifier first front ends. PMID:21779411

  14. Aging properties of Kodak type 101 emulsions

    NASA Technical Reports Server (NTRS)

    Dohne, B.; Feldman, U.; Neupert, W.

    1984-01-01

    Aging tests for several batches of Kodak type 101 emulsion show that storage conditions significantly influence how well the film will maintain its sensitometric properties, with sensitivity and density increasing to a maximum during this period. Any further aging may result in higher fog levels and sensitivity loss. It is noted that storage in an environment free of photographically active compounds allows film property optimization, and that film batches with different sensitivities age differently. Emulsions with maximum 1700-A sensitivity are 2.5 times faster than those at the low end of the sensitivity scale. These sensitive emulsions exhibit significantly accelerated changes in aging properties. Their use in space applications requires careful consideration of time and temperature profiles, encouraging the use of less sensitive emulsions when the controllability of these factors is limited.

  15. Patch testing with thin-layer chromatograms of chamomile tea in patients allergic to sesquiterpene lactones.

    PubMed

    Lundh, Kerstin; Gruvberger, Birgitta; Möller, Halvor; Persson, Lena; Hindsén, Monica; Zimerson, Erik; Svensson, Ake; Bruze, Magnus

    2007-10-01

    Patients with contact allergy to sesquiterpene lactones (SLs) are usually hypersensitive to Asteraceae plant products such as herbal teas. The objective of this study was to show sensitizers in chamomile tea by patch testing with thin-layer chromatograms. Tea made from German chamomile was separated by thin-layer chromatography. Strips of the thin-layer chromatograms were used for patch testing SL-positive patients. 15 (43%) of 35 patients tested positively to 1 or more spots on the thin-layer chromatogram, with many individual reaction patterns. Patch testing with thin-layer chromatograms of German chamomile tea showed the presence of several allergens.

  16. A sandwich-type optical immunosensor based on the alkaline phosphatase enzyme for Salmonella thypimurium detection

    NASA Astrophysics Data System (ADS)

    Widyastuti, E.; Puspitasari Schonherr, M. F.; Masruroh, A.; Anggraeni, R. A.; Nisak, Y. K.; Mursidah, S.

    2018-03-01

    Salmonella is pathogenic bacteria that caused foodborne diseases which being called Salmonellosis. Prevalence of Salmonellosis that being caused by Salmonella thypimurium in Indonesia is quite high. However, detection of Salmonella bacteria in food still limited, complicated, and required a lot time. Sensitive optical assay for Salmonella thypimurium paper based detection has been developed by integrating sandwich assay between antibody-antigen complex and alkaline phosphatase enzyme that produce visible bluish-purple colour with presence of NBT-BCIP substrate. The results showed that Limit of Quantitation of detection is 105 CFU mL-1 with detection time 15 minutes. Linearity test between Colour intensity that produced from Salmonella concentration presence on samples showed that detection has good linearity. Selectivity test exhibited excellent sensitivity with good discrimination against Escherichia coli.

  17. INRA, a new high-frequency antigen in the INDIAN (IN023) blood group system.

    PubMed

    Joshi, Sanmukh R; Sheladiya, Ankita; Mendapara-Dobariya, Kinjal V

    2017-01-01

    The INDIAN blood group system comprises 4 antigens sensitive to enzymes and 2-aminoethyl isothiouronium bromide (AET). The patient's antibody was investigated for its specificity to the high-frequency antigens (HFA) of this system. Low ionic strength solution (LISS)-tube/LISS-indirect antiglobulin test (IAT) methods were used. The patient's red blood cells (RBCs) were tested with antisera to HFA. Her antibody was tested with RBCs lacking the HFA. Furthermore, it was tested with RBCs as untreated or treated with enzyme or AET. The genetic sequence was studied for mutation in CD44 gene that encodes INDIAN antigens. The patient was grouped A1B, RhD+, antibody screening test positive, direct antiglobulin test negative. A negative autocontrol test had suggested to the alloantibody being present. Antibody had agglutinated RBCs in LISS-tube at RT and by LISS-IAT at 37°C. The RBCs of the 11-cell panel, those lacking HFA and from 50 random donors, were agglutinated by her antibody indicating its specificity to the HFA, though the RBCs of Lu (a-b-)/In (Lu) type showed a weaker reaction. The patient's RBCs were agglutinated by antisera to a number of the enzyme-sensitive HFA, including those of INDIAN blood groups. The antibody showed reduced reactivity with the RBCs treated with papain, chymotrypsin, and AET but resistant to trypsin and dithiothreitol. The patient's genetic sequence revealed a novel homozygous mutation 449G>A in exon 5 of CD44 . The antibody to enzyme sensitive HFA was tested for serological and molecular genetics studies and found to be directed to the novel HFA, named as INRA of the INDIAN blood group system and was assigned a numerical symbol IN: 005 by the International Society of Blood Transfusion (ISBT).

  18. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis.

    PubMed

    Wang, Du; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2016-07-14

    Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.

  19. A new screening test for toxicity testing of dental materials.

    PubMed

    Pelka, M; Danzl, C; Distler, W; Petschelt, A

    2000-07-01

    The development of a micro plate assay for cytotoxicity testing of dental materials based on a bioassay using brine shrimp larvae (artemia salina) as sensitive organisms. Brine shrimp larvae are commonly used for cytotoxicity assays in pharmacology. These larvae are sensitive to toxic substances. The ratio between dead larvae (no motility) and living larvae (high motility) in comparison to a control without any toxic substances is used to estimate the toxicity of the test solutions. The test materials (Arabesk((R)), Solitaire((R)), Pertac((R)) II, Tetric((R)), Herculite((R)) and the compomer materials Dyract((R)), Hytac((R)), Compoglass((R))) were polymerized and consecutively milled. After incubation of 1g in 4ml distilled water at 37 degrees C for 48h, the solid materials were separated by centrifugation. The solutions were equibrilated with NaCl to a salt content of 25g/l. Aliquots of 200microl were distributed in eight micro wells and 50microl of a artemia salina containing (n=8-14) solution were added to each well. As controls eight wells with 250microl salt solution containing a comparable number of brine shrimp were used. At baseline, after 2, 5, 24 and 48h, the dead shrimp were counted using a stereo microscope. Finally all shrimps were sacrificed using Na-acid (5%) and counted to get the number of shrimps per well. All compomers and Solitaire caused 100% brine shrimp lethality after 24h and showed significantly (p<0.01, signed rank test) higher toxicities than the remaining composites. With the exception of Pertac II, all composites showed significantly higher toxic values than the control. Pertac II did not show any differences from the controls used. This new technique has some advantages for toxicity testing of restorative materials, because it can quickly be carried out at low costs. The disadvantage is the high quantity of material used and the low sensitivity.

  20. Point-of-care testing system enabling 30 min detection of influenza genes.

    PubMed

    Abe, Tomoteru; Segawa, Yuji; Watanabe, Hidetoshi; Yotoriyama, Tasuku; Kai, Shinichi; Yasuda, Akio; Shimizu, Norio; Tojo, Naoko

    2011-03-21

    We developed a portable and easy-to-use nucleic acid amplification test (NAT) system for use in point-of-care testing (POCT). The system shows sensitivity that is sufficiently higher than that of the currently available rapid diagnostic kit and is comparable to that of real-time reverse transcription polymerase chain reaction (RT-PCR) for influenza testing. This journal is © The Royal Society of Chemistry 2011

  1. Evaluation of Four Diagnostic Tests for Insulin Dysregulation in Adult Light-Breed Horses.

    PubMed

    Dunbar, L K; Mielnicki, K A; Dembek, K A; Toribio, R E; Burns, T A

    2016-05-01

    Several tests have been evaluated in horses for quantifying insulin dysregulation to support a diagnosis of equine metabolic syndrome. Comparing the performance of these tests in the same horses will provide clarification of their accuracy in the diagnosis of equine insulin dysregulation. The aim of this study was to evaluate the agreement between basal serum insulin concentrations (BIC), the oral sugar test (OST), the combined glucose-insulin test (CGIT), and the frequently sampled insulin-modified intravenous glucose tolerance test (FSIGTT). Twelve healthy, light-breed horses. Randomized, prospective study. Each of the above tests was performed on 12 horses. Minimal model analysis of the FSIGTT was considered the reference standard and classified 7 horses as insulin resistant (IR) and 5 as insulin sensitive (IS). In contrast, BIC and OST assessment using conventional cut-off values classified all horses as IS. Kappa coefficients, measuring agreement among BIC, OST, CGIT, and FSIGTT were poor to fair. Sensitivity of the CGIT (positive phase duration of the glucose curve >45 minutes) was 85.7% and specificity was 40%, whereas CGIT ([insulin]45 >100 μIU/mL) sensitivity and specificity were 28.5% and 100%, respectively. Area under the glucose curve (AUCg0-120 ) was significantly correlated among the OST, CGIT, and FSIGTT, but Bland-Altman method and Lin's concordance coefficient showed a lack of agreement. Current criteria for diagnosis of insulin resistance using BIC and the OST are highly specific but lack sensitivity. The CGIT displayed better sensitivity and specificity, but modifications may be necessary to improve agreement with minimal model analysis. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  2. The relationship of speech intelligibility with hearing sensitivity, cognition, and perceived hearing difficulties varies for different speech perception tests

    PubMed Central

    Heinrich, Antje; Henshaw, Helen; Ferguson, Melanie A.

    2015-01-01

    Listeners vary in their ability to understand speech in noisy environments. Hearing sensitivity, as measured by pure-tone audiometry, can only partly explain these results, and cognition has emerged as another key concept. Although cognition relates to speech perception, the exact nature of the relationship remains to be fully understood. This study investigates how different aspects of cognition, particularly working memory and attention, relate to speech intelligibility for various tests. Perceptual accuracy of speech perception represents just one aspect of functioning in a listening environment. Activity and participation limits imposed by hearing loss, in addition to the demands of a listening environment, are also important and may be better captured by self-report questionnaires. Understanding how speech perception relates to self-reported aspects of listening forms the second focus of the study. Forty-four listeners aged between 50 and 74 years with mild sensorineural hearing loss were tested on speech perception tests differing in complexity from low (phoneme discrimination in quiet), to medium (digit triplet perception in speech-shaped noise) to high (sentence perception in modulated noise); cognitive tests of attention, memory, and non-verbal intelligence quotient; and self-report questionnaires of general health-related and hearing-specific quality of life. Hearing sensitivity and cognition related to intelligibility differently depending on the speech test: neither was important for phoneme discrimination, hearing sensitivity alone was important for digit triplet perception, and hearing and cognition together played a role in sentence perception. Self-reported aspects of auditory functioning were correlated with speech intelligibility to different degrees, with digit triplets in noise showing the richest pattern. The results suggest that intelligibility tests can vary in their auditory and cognitive demands and their sensitivity to the challenges that auditory environments pose on functioning. PMID:26136699

  3. Triton Hodge Test: Improved Protocol for Modified Hodge Test for Enhanced Detection of NDM and Other Carbapenemase Producers.

    PubMed

    Pasteran, Fernando; Gonzalez, Lisandro J; Albornoz, Ezequiel; Bahr, Guillermo; Vila, Alejandro J; Corso, Alejandra

    2016-03-01

    Accurate detection of carbapenemase-producing Gram-negative bacilli is of utmost importance for the control of nosocomial spread and the initiation of appropriate antimicrobial therapy. The modified Hodge test (MHT), a carbapenem inactivation assay, has shown poor sensitivity in detecting the worldwide spread of New Delhi metallo-β-lactamase (NDM). Recent studies demonstrated that NDM is a lipoprotein anchored to the outer membrane in Gram-negative bacteria, unlike all other known carbapenemases. Here we report that membrane anchoring of β-lactamases precludes detection of carbapenemase activity by the MHT. We also show that this limitation can be overcome by the addition of Triton X-100 during the test, which allows detection of NDM. We propose an improved version of the assay, called the Triton Hodge test (THT), which allows detection of membrane-bound carbapenemases with the addition of this nonionic surfactant. This test was challenged with a panel of 185 clinical isolates (145 carrying known carbapenemase-encoding genes and 40 carbapenemase nonproducers). The THT displayed test sensitivity of >90% against NDM-producing clinical isolates, while improving performance against other carbapenemases. Ertapenem provided the highest sensitivity (97 to 100%, depending on the type of carbapenemase), followed by meropenem (92.5 to 100%). Test specificity was not affected by the addition of Triton (87.5% and 92.5% with ertapenem and meropenem, respectively). This simple inexpensive test confers a large improvement to the sensitivity of the MHT for the detection of NDM and other carbapenemases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Non-animal sensitization testing: state-of-the-art.

    PubMed

    Vandebriel, Rob J; van Loveren, Henk

    2010-05-01

    Predictive tests to identify the sensitizing properties of chemicals are carried out using animals. In the European Union timelines for phasing out many standard animal tests were established for cosmetics. Following this policy, the new European Chemicals Legislation (REACH) favors alternative methods, if validated and appropriate. In this review the authors aim to provide a state-of-the art overview of alternative methods (in silico, in chemico, and in vitro) to identify contact and respiratory sensitizing capacity and in some occasions give a measure of potency. The past few years have seen major advances in QSAR (quantitative structure-activity relationship) models where especially mechanism-based models have great potential, peptide reactivity assays where multiple parameters can be measured simultaneously, providing a more complete reactivity profile, and cell-based assays. Several cell-based assays are in development, not only using different cell types, but also several specifically developed assays such as three-dimenionally (3D)-reconstituted skin models, an antioxidant response reporter assay, determination of signaling pathways, and gene profiling. Some of these assays show relatively high sensitivity and specificity for a large number of sensitizers and should enter validation (or are indeed entering this process). Integrating multiple assays in a decision tree or integrated testing system is a next step, but has yet to be developed. Adequate risk assessment, however, is likely to require significantly more time and efforts.

  5. Sensitive skin and stratum corneum reactivity to household cleaning products.

    PubMed

    Goffin, V; Piérard-Franchimont, C; Piérard, G E

    1996-02-01

    Products intended for individuals with sensitive skin are being increasingly developed by formulators of household cleaning products. However, there is currently no consensus about the definition and recognition of the biological basis of sensitive skin. We sought to determine the relation between the nature of environmental threat perceived as aggressive by panelists, and the stratum corneum reactivity to household cleaning products as measured by the corneosurfametry test. Results indicate substantial differences in irritancy potential between proprietary products. Corneosurfametry data show significant differences in stratum corneum reactivity between, on the one hand, individuals with either non-sensitive skin or skin sensitive to climate/fabrics, and, on the other hand, individuals with detergent-sensitive skin. It is concluded that sensitive skin is not one single condition. Sound information in rating detergent-sensitive skin may be gained by corneosurfametry.

  6. Integrating heterogeneous drug sensitivity data from cancer pharmacogenomic studies.

    PubMed

    Pozdeyev, Nikita; Yoo, Minjae; Mackie, Ryan; Schweppe, Rebecca E; Tan, Aik Choon; Haugen, Bryan R

    2016-08-09

    The consistency of in vitro drug sensitivity data is of key importance for cancer pharmacogenomics. Previous attempts to correlate drug sensitivities from the large pharmacogenomics databases, such as the Cancer Cell Line Encyclopedia (CCLE) and the Genomics of Drug Sensitivity in Cancer (GDSC), have produced discordant results. We developed a new drug sensitivity metric, the area under the dose response curve adjusted for the range of tested drug concentrations, which allows integration of heterogeneous drug sensitivity data from the CCLE, the GDSC, and the Cancer Therapeutics Response Portal (CTRP). We show that there is moderate to good agreement of drug sensitivity data for many targeted therapies, particularly kinase inhibitors. The results of this largest cancer cell line drug sensitivity data analysis to date are accessible through the online portal, which serves as a platform for high power pharmacogenomics analysis.

  7. Modification of COMT-dependent pain sensitivity by psychological stress and sex.

    PubMed

    Meloto, Carolina B; Bortsov, Andrey V; Bair, Eric; Helgeson, Erika; Ostrom, Cara; Smith, Shad B; Dubner, Ronald; Slade, Gary D; Fillingim, Roger B; Greenspan, Joel D; Ohrbach, Richard; Maixner, William; McLean, Samuel A; Diatchenko, Luda

    2016-04-01

    Catecholamine-O-methyltransferase (COMT) is a polymorphic gene whose variants affect enzymatic activity and pain sensitivity via adrenergic pathways. Although COMT represents one of the most studied genes in human pain genetics, findings regarding its association with pain phenotypes are not always replicated. Here, we investigated if interactions among functional COMT haplotypes, stress, and sex can modify the effect of COMT genetic variants on pain sensitivity. We tested these interactions in a cross-sectional study, including 2 cohorts, one of 2972 subjects tested for thermal pain sensitivity (Orofacial Pain: Prospective Evaluation and Risk Assessment) and one of 948 subjects with clinical acute pain after motor vehicle collision (post-motor vehicle collision). In both cohorts, the COMT high-pain sensitivity (HPS) haplotype showed robust interaction with stress and number of copies of the HPS haplotype was positively associated with pain sensitivity in nonstressed individuals, but not in stressed individuals. In the post-motor vehicle collision cohort, there was additional modification by sex: the HPS-stress interaction was apparent in males, but not in females. In summary, our findings indicate that stress and sex should be evaluated in association studies aiming to investigate the effect of COMT genetic variants on pain sensitivity.

  8. [Application of Fourier amplitude sensitivity test in Chinese healthy volunteer population pharmacokinetic model of tacrolimus].

    PubMed

    Guan, Zheng; Zhang, Guan-min; Ma, Ping; Liu, Li-hong; Zhou, Tian-yan; Lu, Wei

    2010-07-01

    In this study, we evaluated the influence of different variance from each of the parameters on the output of tacrolimus population pharmacokinetic (PopPK) model in Chinese healthy volunteers, using Fourier amplitude sensitivity test (FAST). Besides, we estimated the index of sensitivity within whole course of blood sampling, designed different sampling times, and evaluated the quality of parameters' and the efficiency of prediction. It was observed that besides CL1/F, the index of sensitivity for all of the other four parameters (V1/F, V2/F, CL2/F and k(a)) in tacrolimus PopPK model showed relatively high level and changed fast with the time passing. With the increase of the variance of k(a), its indices of sensitivity increased obviously, associated with significant decrease in sensitivity index for the other parameters, and obvious change in peak time as well. According to the simulation of NONMEM and the comparison among different fitting results, we found that the sampling time points designed according to FAST surpassed the other time points. It suggests that FAST can access the sensitivities of model parameters effectively, and assist the design of clinical sampling times and the construction of PopPK model.

  9. The role of punishment and reward sensitivity in the emotional labor process: a within-person perspective.

    PubMed

    Schreurs, Bert; Guenter, Hannes; Hülsheger, Ute; van Emmerik, Hetty

    2014-01-01

    In this diary study, we tested the possibility that dispositional reward and punishment sensitivity, two central constructs of reinforcement sensitivity theory, would modify the relationship between emotional labor and job-related well-being (i.e., work engagement, emotional exhaustion, depersonalization). Specifically, based on a social functional account of emotion, we hypothesized that surface acting entails the risk of social disapproval and therefore may be more detrimental for high than for low punishment-sensitive individuals. In contrast, deep acting is hypothesized to hold the promise of social approval and therefore may be more beneficial for high than for low reward-sensitive individuals. Hypotheses were tested in a sample of 237 service workers (N = 1,584 daily reports) who completed a general survey and daily surveys over the course of 10 working days. Multilevel analyses showed that surface acting was detrimental to well-being, and more strongly so for high than for low punishment-sensitive individuals. The results are consistent with the idea that heightened sensitivity to social disapproval aggravates the negative effects of surface acting. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  10. Gene expression analysis in zebrafish embryos: a potential approach to predict effect concentrations in the fish early life stage test.

    PubMed

    Weil, Mirco; Scholz, Stefan; Zimmer, Michaela; Sacher, Frank; Duis, Karen

    2009-09-01

    Based on the hypothesis that analysis of gene expression could be used to predict chronic fish toxicity, the zebrafish (Danio rerio) embryo test (DarT), developed as a replacement method for the acute fish test, was expanded to a gene expression D. rerio embryo test (Gene-DarT). The effects of 14 substances on lethal and sublethal endpoints of the DarT and on expression of potential marker genes were investigated: the aryl hydrocarbon receptor 2, cytochrome P450 1A (cypla), heat shock protein 70, fizzy-related protein 1, the transcription factors v-maf musculoaponeurotic fibrosarcoma oncogene family protein g (avian) 1 and NF-E2-p45-related factor, and heme oxygenase 1 (hmox1). After exposure of zebrafish embryos for 48 h, differential gene expression was evaluated using reverse transcriptase-polymerase chain reaction, gel electrophoresis, and densitometric analysis of the gels. All tested compounds significantly affected the expression of at least one potential marker gene, with cyp1a and hmox1 being most sensitive. Lowest-observed-effect concentrations (LOECs) for gene expression were below concentrations resulting in 10% lethal effects in the DarT. For 10 (3,4- and 3,5-dichloroaniline, 1,4-dichlorobenzene, 2,4-dinitrophenol, atrazine, parathion-ethyl, chlorotoluron, genistein, 4-nitroquinoline-1-oxide, and cadmium) out of the 14 tested substances, LOEC values derived with the Gene-DarT differ by a factor of less than 10 from LOEC values of fish early life stage tests with zebrafish. For pentachloroaniline and pentachlorobenzene, the Gene-DarT showed a 23- and 153-fold higher sensitivity, respectively, while for lindane, it showed a 13-fold lower sensitivity. For ivermectin, the Gene-DarT was by a factor of more than 1,000 less sensitive than the acute fish test. The results of the present study indicate that gene expression analysis in zebrafish embryos could principally be used to predict effect concentrations in the fish early life stage test.

  11. Reliability of the anterior drawer test, the pivot shift test, and the Lachman test.

    PubMed

    Kim, S J; Kim, H K

    1995-08-01

    In 147 patients with arthroscopically proved chronic injuries of the anterior cruciate ligament, the anterior drawer test, the Lachman test, and the pivot shift test were done before operation under general or spinal anesthesia. Results of the anterior drawer test were positive in 79.6% of the patients, in 98.6% patients having the Lachman test, and in 89.8% of patients having the pivot shift test. In 19 cases (12.9%), arthroscopic examination showed reattachment of the proximally torn end of the anterior cruciate ligament to the posterior cruciate ligament. In these cases, results of the anterior drawer test were positive in 13 patients (68.4%), in 17 (89.5%) patients having the Lachman test, and in 12 patients (63.2%) having the pivot shift test. In 15 cases with a false negative pivot shift test, arthroscopy showed blockage of anterior subluxation of the lateral tibial condyle by a partially functioning portion of the anterior cruciate ligament, which was reattached to the posterior cruciate ligament in 7 cases. In 2 cases with a false negative Lachman test, there was firm reattachment of the torn end of the anterior cruciate ligament to the proximal portion of the posterior cruciate ligament combined with a bucket handle tear of the medial meniscus. The Lachman test was most sensitive in diagnosing chronic injuries of the anterior cruciate ligament. The pivot shift test was also sensitive but was influenced by many factors.

  12. Development of a rapid, sensitive TaqMan real-time RT-PCR assay for the detection of Rose rosette virus using multiple gene targets.

    PubMed

    Babu, Binoy; Jeyaprakash, Ayyamperumal; Jones, Debra; Schubert, Timothy S; Baker, Carlye; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L

    2016-09-01

    Rose rosette virus (RRV), belonging to the genus Emaravirus, is a highly destructive pathogen that causes rose rosette disease. The disease is a major concern for the rose industry in the U.S. due to the lack of highly sensitive methods for early detection of RRV. This is critical, as early identification of the infected plants and eradication is necessary in minimizing the risks associated with the spread of the disease. A highly reliable, specific and sensitive detection assay is thus required to test and confirm the presence of RRV in suspected plant samples. In this study a TaqMan real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was developed for the detection of RRV from infected roses, utilizing multiple gene targets. Four pairs of primers and probes; two of them (RRV_2-1 and RRV_2-2) based on the consensus sequences of the glycoprotein gene (RNA2) and the other two (RRV_3-2 and RRV_3-5) based on the nucleocapsid gene (RNA3) were designed. The specificity of the primers and probes was evaluated against other representative viruses infecting roses, belonging to the genera Alfamovirus, Cucumovirus, Ilarvirus, Nepovirus, Tobamovirus, and Tospovirus and one Emaravirus (Wheat mosaic virus). Dilution assays using the in vitro transcripts (spiked with total RNA from healthy plants, and non-spiked) showed that all the primers and probes are highly sensitive in consistently detecting RRV with a detection limit of 1 fg. Testing of the infected plants over a period of time (three times in monthly intervals) indicated high reproducibility, with the primer/probe RRV_3-5 showing 100% positive detection, while RRV_2-1, RRV_2-2 and RRV_3-2 showed 90% positive detection. The developed real-time RT-PCR assay is reliable, highly sensitive, and can be easily used in diagnostic laboratories for testing and confirmation of RRV. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A novel double recognition enzyme-linked immunosorbent assay based on the nucleocapsid protein for early detection of European porcine reproductive and respiratory syndrome virus infection.

    PubMed

    Venteo, A; Rebollo, B; Sarraseca, J; Rodriguez, M J; Sanz, A

    2012-04-01

    Precise and rapid detection of porcine reproductive respiratory syndrome virus (PRRSV) infection in swine farms is critical. Improvement of control procedures, such as testing incoming gilt and surveillance of seronegative herds requires more rapid and sensitive methods. However, standard serological techniques detect mainly IgG antibodies. A double recognition enzyme-linked immunosorbent assay (DR-ELISA) was developed for detection of antibodies specific to European PRRSV. This new assay can recognize both IgM and IgG antibodies to PRSSV which might be useful for detecting in routine surveillance assays pigs that are in the very early stages of infection and missed by conventional assays detecting only IgG antibodies. DR-ELISA is based on the double recognition of antigen by antibody. In this study, the recombinant nucleocapsid protein (N) of PRRSV was used both as the coating and the enzyme-conjugated antigen. To evaluate the sensitivity of the assay at early stages of the infection, sera from 69 pigs infected with PRRSV were collected during successive days post infection (pi) and tested. While standard methods showed low sensitivity rates before day 14 pi, DR-ELISA detected 88.4% seropositive samples at day 7 showing greater sensitivity at early stages of the infection. Further studies were carried out to assess the efficiency of the new assay, and the results showed DR-ELISA to be a sensitive and accurate method for early diagnosis of EU-PRRSV infection. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Evaluation of different methods to detect methicillin resistance in Staphylococcus aureus (MRSA).

    PubMed

    Alipour, Farzad; Ahmadi, Malahat; Javadi, Shahram

    2014-01-01

    The studies suggest that dogs living with human are potential risk of becoming MRSA carrier and increased risk of infections caused by MRSA. Phenotypic methods to detect methicillin resistance in Staphylococcus aureus (MRSA) are inadequate. The objective of the present study was to determine methicillin resistance in S. aureus by phenotypic susceptibility test (oxacillin disk diffusion, cefoxitin disk diffusion, oxacillin screen agar) and molecular methods (PCR as a gold standard) and the latex agglutination test for the detection of PBP2a and to evaluate the results of these tests for its sensitivity and specificity. A total of 100 swab samples were taken from muzzle site, in more contact with human, of dogs and MRSA were isolated. Oxacillin (1 μg), cefoxitin (30 μg) disk diffusion and oxacillin screen agar method were used. The isolates were also subjected to latex agglutination test for detection of PBP2a and PCR to detect mecA gene. By PCR 37% of isolates show the presence of mecA. Latex agglutination was found to be the most sensitive (97.29%) and cefoxitin disk diffusion to be the most specific (96.82%) tests for detection of MRSA. Our finding showed that combining oxacillin screen agar or cefoxitin disk diffusion with latex agglutination improves sensitivity and specificity to detect methicillin resistance S. aureus (MRSA) isolates. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  15. [Test and programme sensitivities of screening for colorectal cancer in Reggio Emilia].

    PubMed

    Campari, Cinzia; Sassatelli, Romano; Paterlini, Luisa; Camellini, Lorenzo; Menozzi, Patrizia; Cattani, Antonella

    2011-01-01

    to estimate the sensitivity of the immunochemical test for faecal occult blood (FOBT) and the sensitivity of the colorectal tumour screening programme in the province of Reggio Emilia. retrospective cohort study, including a sample of 80,357 people of both genders, aged 50-69, who underwent FOBT, during the first round of the screening programme in the province of Reggio Emilia, from April 2005 to December 2007. incidence of interval cancer. The proportional incidence method was used to estimate the sensitivity of FOBT and of the screening programme. Data were stratified according to gender, age and year of interval. the overall sensitivity of FOBT was 73.2% (95%IC 63.8-80.7). The sensitivity of FOBT was lower in females (70.5% vs 75.1%), higher in the 50-59 age group (78.6% vs 70.2%) and higher in the colon than rectum (75.1% vs 68.9%). The test had a significantly higher sensitivity in the 1st year of interval than in the 2nd (84.4% vs 60.5%; RR=0.39, 95%IC 0.22-0.70), a difference which was confirmed, also when data were stratified according to gender. The overall sensitivity of the programme is 70.9% (95%IC 61.5-78.5). No statistically significant differences were shown, if data were stratified according to gender, age or site. Again the sensitivity in the 1st year was significantly higher than in the 2nd year of interval (83.2% vs 57.0%; RR=0.41, 95%IC 0.24-0.69). Overall our data confirmed the findings of similar Italian studies, despite subgroup analysis showed some differences in sensitivity in our study.

  16. Effects of ayahuasca on the development of ethanol-induced behavioral sensitization and on a post-sensitization treatment in mice.

    PubMed

    Oliveira-Lima, A J; Santos, R; Hollais, A W; Gerardi-Junior, C A; Baldaia, M A; Wuo-Silva, R; Yokoyama, T S; Costa, J L; Malpezzi-Marinho, E L A; Ribeiro-Barbosa, P C; Berro, L F; Frussa-Filho, R; Marinho, E A V

    2015-04-01

    Hallucinogenic drugs were used to treat alcoholic patients in the past, and recent developments in the study of hallucinogens led to a renewal of interest regarding the application of these drugs in the treatment of addiction. In this scenario, accumulating evidence suggests that the hallucinogenic brew ayahuasca (Aya) may have therapeutic effects on substance abuse problems. We investigated the effects of Aya on spontaneous locomotor activity and ethanol(Eth)-induced hyperlocomotion and subsequent locomotor sensitization by a two-injection protocol. Additionally, we tested the effect of Aya on an 8-day counter-sensitization protocol to modify sensitized responses induced by a repeated treatment with Eth (1.8g/kg) for 8 alternate days. Aya showed high sensitivity in preventing the development of Eth-induced behavioral sensitization, attenuating it at all doses (30, 100, 200, 300 or 500 mg/kg) without modifying spontaneous locomotor activity. At the highest doses (300 and 500 mg/kg), Aya also showed selectivity to both acute and sensitized Eth responses. Finally, a counter-sensitization strategy with 100 or 300 mg/kg of Aya for 8 consecutive days after the establishment of Eth-induced behavioral sensitization was effective in blocking its subsequent expression on an Eth challenge. We demonstrated that Aya not only inhibits early behaviors associated with the initiation and development of Eth addiction, but also showed effectiveness in reversing long-term drug effects expression, inhibiting the reinstatement of Eth-induced behavioral sensitization when administered in the Eth-associated environment. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Behavioral cross-sensitization between DOCA-induced sodium appetite and cocaine-induced locomotor behavior

    PubMed Central

    Acerbo, Martin J.; Johnson, Alan Kim

    2011-01-01

    Behavioral sensitization involves increases in the magnitude of a response to a stimulus after repeated exposures to the same response initiator. Administration of psychomotor stimulants and the induction of appetitive motivational states associated with natural reinforcers like sugar and salt are among experimental manipulations producing behavioral sensitization. In rats, repeated administration of the mineralocorticoid agonist deoxycorticosterone acetate (DOCA) initially induces incremental increases in daily hypertonic saline consumption (i.e., sensitization of sodium appetite) in spite of the retention of sodium. The present studies investigated whether sodium appetite sensitization induced by DOCA shares mechanisms similar to those of psychomotor stimulant-induced sensitization, and whether there is evidence for reciprocal cross-sensitization. In Experiments 1 and 3, rats received control or cocaine treatments to induce locomotor sensitization. A week later DOCA (or vehicle) was administered to generate a sodium appetite. Animals pretreated with cocaine showed a greater sodium appetite. In Experiment 2, the order of the putative sensitizing treatments was reversed. Rats first received either a series of DOCA or vehicle treatments either with or without access to saline and were later tested for sensitization of the locomotor response to cocaine. Animals pretreated with DOCA without access to saline showed greater locomotor responses to cocaine than animals receiving vehicle treatments. Together these experiments indicate that treatments generating a sustained salt appetite and producing cocaine-induced psychomotor responses show reciprocal behavioral cross-sensitization. The underlying mechanisms accounting for this relationship may be the fact that psychostimulants and an unresolved craving for sodium can act as potent stressors. PMID:21352848

  18. Comparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression

    PubMed Central

    Hu, Rongrong; Wang, Chenkun; Gu, Yangshun; Racette, Lyne

    2016-01-01

    Abstract Detection of progression is paramount to the clinical management of glaucoma. Our goal is to compare the performance of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry in monitoring glaucoma progression. Longitudinal data of paired SAP, SWAP, and FDT from 113 eyes with primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Data from all tests were expressed in comparable units by converting the sensitivity from decibels to unitless contrast sensitivity and by expressing sensitivity values in percent of mean normal based on an independent dataset of 207 healthy eyes with aging deterioration taken into consideration. Pointwise linear regression analysis was performed and 3 criteria (conservative, moderate, and liberal) were used to define progression and improvement. Global mean sensitivity (MS) was fitted with linear mixed models. No statistically significant difference in the proportion of progressing and improving eyes was observed across tests using the conservative criterion. Fewer eyes showed improvement on SAP compared to SWAP and FDT using the moderate criterion; and FDT detected less progressing eyes than SAP and SWAP using the liberal criterion. The agreement between these test types was poor. The linear mixed model showed a progressing trend of global MS overtime for SAP and SWAP, but not for FDT. The baseline estimate of SWAP MS was significantly lower than SAP MS by 21.59% of mean normal. FDT showed comparable estimation of baseline MS with SAP. SWAP and FDT do not appear to have significant benefits over SAP in monitoring glaucoma progression. SAP, SWAP, and FDT may, however, detect progression in different glaucoma eyes. PMID:26886602

  19. Sensitivity and Specificity of Self-Reported Olfactory Function in a Home-Based Study of Independent-Living, Healthy Older Women

    PubMed Central

    Rawal, Shristi; Hoffman, Howard J.; Chapo, Audrey K.

    2015-01-01

    Introduction The 2011–14 US National Health and Nutrition Examination Survey chemosensory protocol asks adults to self-rate their orthonasal (via nostrils) and retronasal (via mouth) smell abilities for subsequent odor identification testing. From data collected with a similar protocol, we aimed to identify a self-reported olfactory index that showed the best sensitivity (correctly identifying dysfunction) and specificity (correctly indentifying normosmia) with measured olfaction. Methods In home-based testing, 121 independent-living older women (age 73±7 years) reported their olfactory function by interviewer-administered survey. Olfactory function was measured orthonasally via composite (odor threshold, identification task) or identification task alone. Results Only 16 % of women self-rated “below average” smell function. More women perceived loss of smell (38 %) or flavor (30 %) with aging. The rate of measured dysfunction was 30 % by composite (threshold and identification) and 21.5 % by identification task, the latter misclassifying some mild dysfunction as normosmia. An index of self-rated smell function and perceived loss yielded the most favorable sensitivity (65 %) and specificity (77 %) to measured function. Self-rated olfaction showed better agreement with severe measured dysfunction; mild dysfunction was less noticed. Conclusions Self-reported indices that query about current and perceived changes in smell and flavor with aging showed better sensitivity estimates than those previously reported. Specificity was somewhat lower—some older adults may correctly perceive loss unidentified in a single assessment, or have a retronasal impairment that was undetected by an orthonasal measure. Implications Our findings should inform self-rated measures that screen for severe olfactory dysfunction in clinical/community settings where testing is not routine. PMID:25866597

  20. Detection of Leishmania DNA in saliva among patients with HIV/AIDS in Trang Province, southern Thailand.

    PubMed

    Pandey, Netranapha; Siripattanapipong, Suradej; Leelayoova, Saovanee; Manomat, Jipada; Mungthin, Mathirut; Tan-Ariya, Peerapan; Bualert, Lertwut; Naaglor, Tawee; Siriyasatien, Padet; Phumee, Atchara; Piyaraj, Phunlerd

    2018-06-08

    Leishmaniasis is a neglected tropical disease causing opportunistic infection among patients with HIV/AIDS. The fatal form of this disease is visceral leishmaniasis (VL). DNA of Leishmania can be detected in saliva, for which the collection is noninvasive and requires little expertise. This study aimed to evaluate the sensitivity and specificity of a nested-PCR to amplify the Internal Transcribed Spacer 1 (ITS1) to detect Leishmania DNA in paired saliva and buffy coat samples of 305 Thai patients with HIV/AIDS in Trang Hospital, Trang Province, southern Thailand. For asymptomatic Leishmania infection among Thai patients with HIV/AIDS, the sensitivity and specificity of the nested-PCR-ITS1 in buffy coat were 73.9 and 100%, respectively. However, the sensitivity in saliva was 26.1% and specificity was 100%. Using the nested-PCR-ITS1, saliva and buffy coat samples showed positive agreement in only 52.0% of patients. Saliva tested results with the nested-PCR-ITS1 showed positive agreement with the Direct Agglutination Test (DAT) in 46.5% of patients. Only 12.1% of the samples showed positive agreement for Leishmania infection among all the three tests: saliva, buffy coat and DAT results. Using nucleotide sequencing, at least three species of Leishmania infection were identified in saliva, i.e., L. siamensis (n = 28), L. martiniquensis (n = 9), and L. donovani complex (n = 1). As a result, buffy coat still appears to be a better specimen to diagnose asymptomatic VL infection among individuals with HIV. However, the use of both buffy coat and saliva together as clinical specimens would increase the sensitivity of Leishmania detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  2. Is the risk for soil arthropods covered by new data requirements under the EU PPP Regulation No. 1107/2009?

    PubMed

    Kohlschmid, E; Ruf, D

    2016-12-01

    Testing of effects on earthworms and non-target foliar arthropods is an integral part of the ecotoxicological risk assessment for the authorization of plant protection products. According to the new data requirements, which came into force in 2014 for active substances and in 2016 for plant protection products, the chronic earthworm toxicity test with Eisenia fetida based on reproductive, growth, and behavioral effects instead of the acute earthworm toxicity test based on mortality, has to be conducted routinely. Additional testing of effects on soil arthropods (Folsomia candida, Hyposaspis aculeifer) is required if the risk assessment of foliar applications raises concerns regarding non-target foliar arthropods (Aphidius rhopalosiphi, Typhlodromus pyri) or if the product is applied directly on or into the soil. Thus, it was investigated whether the sublethal earthworm endpoint is more sensitive than the sublethal soil arthropod endpoint for different types of pesticides and whether the risk assessment for non-target arthropods would trigger the testing of effects on soil arthropods in the cases where soil arthropods are more sensitive than earthworms. Toxicity data were obtained from Swiss ecotoxicological database, EFSA Conclusions and scientific literature. For insecticides and herbicides, no general conclusion regarding differences in sensitivity of either earthworms or soil arthropods based on sublethal endpoints were possible. For fungicides, the data indicated that in general, earthworms seemed to be more sensitive than soil arthropods. In total, the sublethal F. candida or H. aculeifer endpoint was lower than the sublethal E. fetida endpoint for 23 (34 %) out of 68 active substances. For 26 % of these 23 active substances, testing of soil arthropods would not have been triggered due to the new data requirement. These results based on sublethal endpoints show that earthworms and soil arthropods differ in sensitivity toward certain active substances and that the risk assessment for non-target foliar arthropods did not always trigger soil arthropod testing in the cases where soil arthropods were more sensitive than earthworms.

  3. Diagnostic Performance of a Molecular Test versus Clinician Assessment of Vaginitis

    PubMed Central

    Gaydos, Charlotte A.; Nyirjesy, Paul; Paradis, Sonia; Kodsi, Salma; Cooper, Charles K.

    2018-01-01

    ABSTRACT Vaginitis is a common complaint, diagnosed either empirically or using Amsel's criteria and wet mount microscopy. This study sought to determine characteristics of an investigational test (a molecular test for vaginitis), compared to reference, for detection of bacterial vaginosis, Candida spp., and Trichomonas vaginalis. Vaginal specimens from a cross-sectional study were obtained from 1,740 women (≥18 years old), with vaginitis symptoms, during routine clinic visits (across 10 sites in the United States). Specimens were analyzed using a commercial PCR/fluorogenic probe-based investigational test that detects bacterial vaginosis, Candida spp., and Trichomonas vaginalis. Clinician diagnosis and in-clinic testing (Amsel's test, potassium hydroxide preparation, and wet mount) were also employed to detect the three vaginitis causes. All testing methods were compared to the respective reference methods (Nugent Gram stain for bacterial vaginosis, detection of the Candida gene its2, and Trichomonas vaginalis culture). The investigational test, clinician diagnosis, and in-clinic testing were compared to reference methods for bacterial vaginosis, Candida spp., and Trichomonas vaginalis. The investigational test resulted in significantly higher sensitivity and negative predictive value than clinician diagnosis or in-clinic testing. In addition, the investigational test showed a statistically higher overall percent agreement with each of the three reference methods than did clinician diagnosis or in-clinic testing. The investigational test showed significantly higher sensitivity for detecting vaginitis, involving more than one cause, than did clinician diagnosis. Taken together, these results suggest that a molecular investigational test can facilitate accurate detection of vaginitis. PMID:29643195

  4. Suprathreshold Contrast Sensitivity Vision Test Chart

    DTIC Science & Technology

    1991-07-14

    with data collected on patients having amblyopia , glaucoma and macular degeneration showed that the SCTS may be effectively used as an initial...dramatically in certain cases of abnormal vision, such as amblyopia (Ginsburg, 1978, 1981; Hess, Bradley and Piotrowski, 1983; Loshin and Levi, 1983). The...combination of frequencies. Amblyopia results in marked losses of contrast sensitivity particularly at high spatial frequencies, but may also result in

  5. A modified haemagglutination inhibition test for rubella antibodies, using standardized, freeze-dried reagents. Report of a comparative multi-centre trial.

    PubMed Central

    van Weemen, B.; Kacaki, J.

    1976-01-01

    A modified haemagglutination inhibition test for rubella antibodies, using standardized freeze-dried reagents, was developed and compared with haemagglutination inhibition tests using fresh erythrocytes. This comparison was made in collaboration with six European laboratories. A total of 4205 serum samples were tested. The results show that: (1) Sensitivity and reliability of the modified test are good; (2) the modified test can be performed in polystyrene microtitration plates. PMID:789763

  6. Study of the pH-sensitive mechanism of tumor-targeting liposomes.

    PubMed

    Fan, Yang; Chen, Cong; Huang, Yiheng; Zhang, Fang; Lin, Guimei

    2017-03-01

    Currently, the phosphatidylethanolamine-based, pH-sensitive, liposome drug-delivery system has been widely developed for efficient, targeted cancer therapy. However, the mechanism of pH sensitivity was unclear; it is a main obstacle in controlling the preparation of pH-sensitive liposomes (PSLs).Therefore, our research is aimed at clarifying the pH-response mechanism of the various molecules that compose liposomes. We chose the small pH-sensitive molecules oleic acid (OA), linoleic acid (LA) and cholesteryl hemisuccinate (CHEMS) and the fundamental lipids cholesterol and phosphatidylethanolamine (PE) as test molecules. The PSLs were prepared using the thin-film hydration method and characterized in detail at various pH values (pH 5.0, 6.0 and 7.4), including particle size, ζ-potential, drug encapsulation efficiency and drug loading. The surface structure was observed by transmission electron microscopy (TEM), and the electrical conductivity of the liposome dispersion was also tested. The calorimetric analysis was conducted by Nano-differential scanning calorimetry (Nano-DSC). The in vitro drug release profile showed that PSLs exhibit good pH sensitivity. At neutral pH, the particle size was approximately 150nm, and it dramatically increased at pH 5.0. The ζ-potential increased as the pH decreased. The Nano-DSC results showed that cholesterol and CHEMS can both increase the stability and phase transfer temperature of PSLs. Conductivity increased to a maximum at pH 5.0 and was rather low at pH 7.4. In conclusion, results show that the three kinds of liposomes have pH responsive release characteristics in acidic pH. The OA-PSLs have a pH sensitive point of 5. Since CHEMS has a cholesterol-like structure, it can stabilizes the phospholipid bilayer under neutral conditions as shown in the Nano-DSC data, and because it has a special steroidal rigid structure, it exhibits better pH response characteristics under acidic conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Self-rating inventory for posttraumatic stress disorder: review of the psychometric properties of a new brief Dutch screening instrument.

    PubMed

    Hovens, J E; Bramsen, I; van der Ploeg, H M

    2002-06-01

    The Self-rating Inventory for Posttraumatic Stress Disorder of 22 items was developed for use with populations without identified traumatic experiences. The inventory has been used extensively in survey research in The Netherlands. This paper examines the psychometric properties. In four different groups (trauma and psychiatric patients, elderly Dutch subjects, former peacekeepers, and medical students) internal consistency, test-retest reliability, concurrent and discriminant validity, and sensitivity and specificity are analyzed. The inventory showed good internal consistency, test-retest reliability, concurrent and discriminant validity, and high sensitivity and specificity. It appears to be valuable for survey research on posttraumatic stress in nonselected populations. As a screening device, high sensitivity for PTSD symptoms is evident even when the traumatic event has not been defined.

  8. The association of noise sensitivity with music listening, training, and aptitude.

    PubMed

    Kliuchko, Marina; Heinonen-Guzejev, Marja; Monacis, Lucia; Gold, Benjamin P; Heikkilä, Kauko V; Spinosa, Vittoria; Tervaniemi, Mari; Brattico, Elvira

    2015-01-01

    After intensive, long-term musical training, the auditory system of a musician is specifically tuned to perceive musical sounds. We wished to find out whether a musician's auditory system also develops increased sensitivity to any sound of everyday life, experiencing them as noise. For this purpose, an online survey, including questionnaires on noise sensitivity, musical background, and listening tests for assessing musical aptitude, was administered to 197 participants in Finland and Italy. Subjective noise sensitivity (assessed with the Weinstein's Noise Sensitivity Scale) was analyzed for associations with musicianship, musical aptitude, weekly time spent listening to music, and the importance of music in each person's life (or music importance). Subjects were divided into three groups according to their musical expertise: Nonmusicians (N = 103), amateur musicians (N = 44), and professional musicians (N = 50). The results showed that noise sensitivity did not depend on musical expertise or performance on musicality tests or the amount of active (attentive) listening to music. In contrast, it was associated with daily passive listening to music, so that individuals with higher noise sensitivity spent less time in passive (background) listening to music than those with lower sensitivity to noise. Furthermore, noise-sensitive respondents rated music as less important in their life than did individuals with lower sensitivity to noise. The results demonstrate that the special sensitivity of the auditory system derived from musical training does not lead to increased irritability from unwanted sounds. However, the disposition to tolerate contingent musical backgrounds in everyday life depends on the individual's noise sensitivity.

  9. Resting spontaneous baroreflex sensitivity and cardiac autonomic control in anabolic androgenic steroid users

    PubMed Central

    dos Santos, Marcelo R.; Sayegh, Ana L.C.; Armani, Rafael; Costa-Hong, Valéria; de Souza, Francis R.; Toschi-Dias, Edgar; Bortolotto, Luiz A.; Yonamine, Mauricio; Negrão, Carlos E.; Alves, Maria-Janieire N.N.

    2018-01-01

    OBJECTIVES: Misuse of anabolic androgenic steroids in athletes is a strategy used to enhance strength and skeletal muscle hypertrophy. However, its abuse leads to an imbalance in muscle sympathetic nerve activity, increased vascular resistance, and increased blood pressure. However, the mechanisms underlying these alterations are still unknown. Therefore, we tested whether anabolic androgenic steroids could impair resting baroreflex sensitivity and cardiac sympathovagal control. In addition, we evaluate pulse wave velocity to ascertain the arterial stiffness of large vessels. METHODS: Fourteen male anabolic androgenic steroid users and 12 nonusers were studied. Heart rate, blood pressure, and respiratory rate were recorded. Baroreflex sensitivity was estimated by the sequence method, and cardiac autonomic control by analysis of the R-R interval. Pulse wave velocity was measured using a noninvasive automatic device. RESULTS: Mean spontaneous baroreflex sensitivity, baroreflex sensitivity to activation of the baroreceptors, and baroreflex sensitivity to deactivation of the baroreceptors were significantly lower in users than in nonusers. In the spectral analysis of heart rate variability, high frequency activity was lower, while low frequency activity was higher in users than in nonusers. Moreover, the sympathovagal balance was higher in users. Users showed higher pulse wave velocity than nonusers showing arterial stiffness of large vessels. Single linear regression analysis showed significant correlations between mean blood pressure and baroreflex sensitivity and pulse wave velocity. CONCLUSIONS: Our results provide evidence for lower baroreflex sensitivity and sympathovagal imbalance in anabolic androgenic steroid users. Moreover, anabolic androgenic steroid users showed arterial stiffness. Together, these alterations might be the mechanisms triggering the increased blood pressure in this population. PMID:29791601

  10. Resting spontaneous baroreflex sensitivity and cardiac autonomic control in anabolic androgenic steroid users.

    PubMed

    Santos, Marcelo R Dos; Sayegh, Ana L C; Armani, Rafael; Costa-Hong, Valéria; Souza, Francis R de; Toschi-Dias, Edgar; Bortolotto, Luiz A; Yonamine, Mauricio; Negrão, Carlos E; Alves, Maria-Janieire N N

    2018-05-21

    Misuse of anabolic androgenic steroids in athletes is a strategy used to enhance strength and skeletal muscle hypertrophy. However, its abuse leads to an imbalance in muscle sympathetic nerve activity, increased vascular resistance, and increased blood pressure. However, the mechanisms underlying these alterations are still unknown. Therefore, we tested whether anabolic androgenic steroids could impair resting baroreflex sensitivity and cardiac sympathovagal control. In addition, we evaluate pulse wave velocity to ascertain the arterial stiffness of large vessels. Fourteen male anabolic androgenic steroid users and 12 nonusers were studied. Heart rate, blood pressure, and respiratory rate were recorded. Baroreflex sensitivity was estimated by the sequence method, and cardiac autonomic control by analysis of the R-R interval. Pulse wave velocity was measured using a noninvasive automatic device. Mean spontaneous baroreflex sensitivity, baroreflex sensitivity to activation of the baroreceptors, and baroreflex sensitivity to deactivation of the baroreceptors were significantly lower in users than in nonusers. In the spectral analysis of heart rate variability, high frequency activity was lower, while low frequency activity was higher in users than in nonusers. Moreover, the sympathovagal balance was higher in users. Users showed higher pulse wave velocity than nonusers showing arterial stiffness of large vessels. Single linear regression analysis showed significant correlations between mean blood pressure and baroreflex sensitivity and pulse wave velocity. Our results provide evidence for lower baroreflex sensitivity and sympathovagal imbalance in anabolic androgenic steroid users. Moreover, anabolic androgenic steroid users showed arterial stiffness. Together, these alterations might be the mechanisms triggering the increased blood pressure in this population.

  11. Novel approach based on one-tube nested PCR and a lateral flow strip for highly sensitive diagnosis of tuberculous meningitis.

    PubMed

    Sun, Yajuan; Chen, Jiajun; Li, Jia; Xu, Yawei; Jin, Hui; Xu, Na; Yin, Rui; Hu, Guohua

    2017-01-01

    Rapid and sensitive detection of Mycobacterium tuberculosis (M. Tb) in cerebrospinal fluid is crucial in the diagnosis of tuberculous meningitis (TBM), but conventional diagnostic technologies have limited sensitivity and specificity or are time-consuming. In this work, a novel, highly sensitive molecular diagnostic method, one-tube nested PCR-lateral flow strip test (OTNPCR-LFST), was developed for detecting M. tuberculosis. This one-tube nested PCR maintains the sensitivity of conventional two-step nested PCR and reduces both the chance of cross-contamination and the time required for analysis. The PCR product was detected by a lateral flow strip assay, which provided a basis for migration of the test to a point-of-care (POC) microfluidic format. The developed assay had an improved sensitivity compared with traditional PCR, and the limit of detection was up to 1 fg DNA isolated from M. tuberculosis. The assay was also specific for M. tuberculosis, and no cross-reactions were found in other non-target bacteria. The application of this technique to clinical samples was successfully evaluated, and OTNPCR-LFST showed 89% overall sensitivity and 100% specificity for TBM patients. This one-tube nested PCR-lateral flow strip assay is useful for detecting M. tuberculosis in TBM due to its rapidity, high sensitivity and simple manipulation.

  12. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    PubMed

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most effective test in MCI detection, especially for the population with symptoms of memory deterioration. They can be potentially used as the triage screening test for MCI in primary care setting. But when a patient shows cognitive impairments beyond memory deterioration, a more comprehensive test such as the MoCA should be used. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  13. Accuracy of the volume-viscosity swallow test for clinical screening of oropharyngeal dysphagia and aspiration.

    PubMed

    Clavé, Pere; Arreola, Viridiana; Romea, Maise; Medina, Lucía; Palomera, Elisabet; Serra-Prat, Mateu

    2008-12-01

    To determine the accuracy of the bedside volume-viscosity swallow test (V-VST) for clinical screening of impaired safety and efficacy of deglutition. We studied 85 patients with dysphagia and 12 healthy subjects. Series of 5-20 mL nectar (295.02 mPa.s), liquid (21.61 mPa.s) and pudding (3682.21 mPa.s) bolus were administered during the V-VST and videofluoroscopy. Cough, fall in oxygen saturation > or =3%, and voice changes were considered signs of impaired safety, and piecemeal deglutition and oropharyngeal residue, signs of impaired efficacy. Videofluoroscopy showed patients had prolonged swallow response (> or =1064 ms); 52.1% had safe swallow at nectar, 32.9%, at liquid (p<0.05), and 80.6% at pudding viscosity (p<0.05); 29.4% had aspirations, and 45.8% oropharyngeal residue. The V-VST showed 83.7% sensitivity and 64.7% specificity for bolus penetration into the larynx and 100% sensitivity and 28.8% specificity for aspiration. Sensitivity of V-VST was 69.2% for residue, 88.4% for piecemeal deglutition, and 84.6% for identifying patients whose deglutition improved by enhancing bolus viscosity. Specificity was 80.6%, 87.5%, and 73.7%, respectively. The V-VST is a sensitive clinical method to identify patients with dysphagia at risk for respiratory and nutritional complications, and patients whose deglutition could be improved by enhancing bolus viscosity. Patients with a positive test should undergo videofluoroscopy.

  14. The noninvasive mouse ear swelling assay. I. Refinements for detecting weak contact sensitizers.

    PubMed

    Thorne, P S; Hawk, C; Kaliszewski, S D; Guiney, P D

    1991-11-01

    The noninvasive mouse ear swelling assay (MESA) is a model for delayed-type hypersensitivity that holds promise as a testing protocol for allergic contact dermatitis (ACD). The MESA employs only topical sensitization on the abdomen and does not use injections, adjuvants, anesthesia, occlusion, or disruption of the stratum corneum. Five days after induction, the ears are challenged topically and ear swelling measurements taken at 24, 48, and 72 hr indicate the extent of ACD. In this study, refinements of the assay were explored in BALB/cBy mice using dinitrofluorobenzene (DNFB) and dinitrochlorobenzene (DNCB). A complete dose-response curve was developed for DNFB and the dose which sensitized half the mice in a group (SD50, 0.001%, w/v) was used to test noninvasive enhancement protocols. Several triple-dose protocols tested produced no increase in responsiveness and daily dosing showed a trend toward tolerance induction yielding 20% positive responses. Dietary vitamin A supplementation produced a dramatic enhancement of the responses: ear thickness increase was doubled and the SD50 sensitized 94 to 100% of the mice in the vitamin A groups. We conclude that the MESA allowed identification of ACD potency for known sensitizers at very low concentrations which do not produce ACD with other techniques. The importance of dose-response studies for avoiding the high-dose reduced-response region was also shown. Based on the observation that the vitamin A-augmented MESA was considerably more sensitive than with regular feed, a companion study (P.S. Thorne. C. Hawk, S.D. Kaliszewski, P.D. Guiney, Fundam. Appl. Tox. 17, 807-820, 1991) presents tests of the enhancements to the MESA developed in this work, using weak sensitizers and complex mixtures.

  15. Increased sensitivity of prolonged P-wave during exercise stress test in detection of angiographically documented coronary artery disease.

    PubMed

    Wsol, Agnieszka; Wydra, Wioletta; Chmielewski, Marek; Swiatowiec, Andrzej; Kuch, Marek

    2017-01-01

    A retrospective study was designed to investigate P-wave duration changes in exercise stress test (EST) for the prediction of angiographically documented substantial coronary artery disease (CAD). We analyzed 265 cases of patients, who underwent EST and subsequently coronary angiography. Analysis of P-wave duration was performed in leads II, V5 at rest, and in the recovery period. The sensitivity and specificity for the isolated ST-segment depression were only 31% and 76%, respectively. The combination of ST-depression with other exercise-induced clinical and electrocardio-graphic abnormalities (chest pain, ventricular arrhythmia, hypotension, left bundle branch block) was characterized by 41% sensitivity and 69% specificity. The combination of abnormal recovery P-wave duration (≥ 120 ms) with ST-depression and other exercise-induced abnormalities had 83% sensitivity but only 20% specificity. Combined analysis of increased delta P-wave duration, ST-depression and other exercise-induced abnormalities had 69% sensitivity and 42% specificity. Sensitivity and specificity of the increase in delta P-wave duration for left CAD was 69% and 47%, respectively, and for 3-vessel CAD 70% and 50%, respectively. The presence of arterial hypertension negatively influenced the prog-nostic value of P-wave changes in the stress test. The results of the study show that an addition of P-wave duration changes assessment to ST-depression analysis and other exercise-induced abnormalities increase sensitivity of EST, especially for left CAD and 3-vessel coronary disease. We have also provided evidence for the negative influence of the presence of arterial hypertension on the predictive value of P-wave changes in the stress test. (Cardiol J 2017; 24, 2: 159-166).

  16. Comparing the performance of circulating cathodic antigen and Kato-Katz techniques in evaluating Schistosoma mansoni infection in areas with low prevalence in selected counties of Kenya: a cross-sectional study.

    PubMed

    Okoyo, Collins; Simiyu, Elses; Njenga, Sammy M; Mwandawiro, Charles

    2018-04-11

    Kato-Katz technique has been the mainstay test in Schistosoma mansoni diagnosis in endemic areas. However, recent studies have documented its poor sensitivity in evaluating Schistosoma mansoni infection especially in areas with lower rates of transmission. It's the primary diagnostic tool in monitoring impact of the Kenya national school based deworming program on infection transmission, but there is need to consider a more sensitive technique as the prevalence reduces. Therefore, this study explored the relationship between results of the stool-based Kato-Katz technique with urine-based point-of-care circulating cathodic antigen (POC-CCA) test in view to inform decision-making by the program in changing from Kato-Katz to POC-CCA test. We used two cross-sectional surveys conducted pre- and post- mass drug administration (MDA) using praziquantel in a representative random sample of children from 18 schools across 11 counties. A total of 1944 children were randomly sampled for the study. Stool and urine samples were tested for S. mansoni infection using Kato-Katz and POC-CCA methods, respectively. S. mansoni prevalence using each technique was calculated and 95% confidence intervals obtained using binomial regression model. Specificity (Sp) and sensitivity (Sn) were determined using 2 × 2 contingency tables and compared using the McNemar's chi-square test. A total of 1899 and 1878 children were surveyed at pre- and post-treatment respectively. S. mansoni infection prevalence was 26.5 and 21.4% during pre- and post-treatment respectively using POC-CCA test, and 4.9 and 1.5% for pre- and post-treatment respectively using Kato-Katz technique. Taking POC-CCA as the gold standard, Kato-Katz was found to have significantly lower sensitivity both at pre- and post-treatment, Sn = 12.5% and Sn = 5.2% respectively, McNemar test χ 2 m  = 782.0, p < 0.001. In overall, the results showed a slight/poor agreement between the two methods, kappa index (k) = 0.11, p < 0.001, inter-rater agreement = 77.1%. Results showed POC-CCA technique as an effective, sensitive and accurate screening tool for Schistosoma mansoni infection in areas of low prevalence. It was up to 14-fold accurate than Kato-Katz which had extremely inadequate sensitivity. We recommend usage of POC-CCA alongside Kato-Katz examinations by Schistosomiasis control programs in low prevalence areas.

  17. Comparative performance of aldolase and lactate dehydrogenase rapid diagnostic tests in Plasmodium vivax detection

    PubMed Central

    2014-01-01

    Background Misdiagnosis of malaria by commercial rapid diagnostic tests (RDTs) is a major cause of concern in the diagnosis of malaria. This retrospective study was aimed at assessing the relative performance of four RDTs with emphasis on the detection of two Plasmodium vivax antigens: aldolase and lactate dehydrogenase (LDH). Methods Three commercially available Plasmodium LDH or aldolase antigen detection kits (One Step Malaria P.f/P.v, ParaHit Total ver. 1.0, SD Bioline Malaria) and an anti-P. vivax aldolase-specific monoclonal antibody (mAb) pair 1C3-12 F10 were evaluated with P. vivax positive as well as non-P. vivax samples and healthy samples using blood smear examination as standard. Each test was read according to the manufacturer’s instructions. Results MAb 1C3-12 F10 pair targeting P. vivax-specific aldolase exhibited very good specificity and sensitivity of 100 and 97.4%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) of 100 and 99.5%, respectively, were also observed. The anti-P. vivax LDH in the One-Step Malaria P.f/P.v test showed sensitivity, specificity, PPV and NPV of 93.5, 98.0, 88.9 and 98.8%, respectively. ParaHit Total ver. 1.0 targeting the pan-aldolase antigen showed sensitivity, specificity of 97.4 and 99.6%, respectively. PPV and NPV were both 99.5%. SD Bioline had sensitivity, specificity, PPV and NPV of 93.5, 100, 100 and 98.8%, respectively. The overall sensitivity and specificity of all four RDTs were acceptable, especially for the aldolase detection tests. Five (6.5%) of the P. vivax-positive samples (n = 77) that were confirmed by microscopic examination as well as the two aldolase detection RDTs (mAb 1C3-12 F10 and ParaHit Total ver.1.0) were undetected by the two LDH detection RDTs (One Step Malaria P.f/P.v and SD Bioline). Similarly, two positive samples (2.6%) that were positively confirmed by the LDH detection RDTs were also undetected by the aldolase detection test kits. Conclusion Aldolase and LDH antigens perform differently in different P. vivax samples; hence there is a high risk of misdiagnosis when monoclonal antibodies are used against only one particular antigen in the test. A combination of both aldolase and LDH in RDTs for the rapid diagnosis of P. vivax will enhance the sensitivity of the assay and reduce misdiagnosis. PMID:25015737

  18. Study on validity of a rapid diagnostic test kit versus light microscopy for malaria diagnosis in Ahmedabad city, India.

    PubMed

    Vyas, S; Puwar, B; Patel, V; Bhatt, G; Kulkarni, S; Fancy, M

    2014-05-01

    Light microscopy of blood smears for diagnosis of malaria in the field has several limitations, notably delays in diagnosis. This study in Ahmedabad in Gujarat State, India, evaluated the diagnostic performance of a rapid diagnostic test for malaria (SD Bioline Malaria Ag P.f/Pan) versus blood smear examination as the gold standard. All fever cases presenting at 13 urban health centres were subjected to rapid diagnostic testing and thick and thin blood smears. A total of 677 cases with fever were examined; 135 (20.0%) tested positive by rapid diagnostic test and 86 (12.7%) by blood smear. The sensitivity of the rapid diagnostic test for malaria was 98.8%, specificity was 91.5%, positive predictive value 63.0% and negative predictive value 99.8%. For detection of Plasmodium falciparum the sensitivity of rapid diagnostic test was 100% and specificity was 97.3%. The results show the acceptability of the rapid test as an alternative to light microscopy in the field setting.

  19. Assessing neglect dyslexia with compound words.

    PubMed

    Reinhart, Stefan; Schunck, Alexander; Schaadt, Anna Katharina; Adams, Michaela; Simon, Alexandra; Kerkhoff, Georg

    2016-10-01

    The neglect syndrome is frequently associated with neglect dyslexia (ND), which is characterized by omissions or misread initial letters of single words. ND is usually assessed with standardized reading texts in clinical settings. However, particularly in the chronic phase of ND, patients often report reading deficits in everyday situations but show (nearly) normal performances in test situations that are commonly well-structured. To date, sensitive and standardized tests to assess the severity and characteristics of ND are lacking, although reading is of high relevance for daily life and vocational settings. Several studies found modulating effects of different word features on ND. We combined those features in a novel test to enhance test sensitivity in the assessment of ND. Low-frequency words of different length that contain residual pronounceable words when the initial letter strings are neglected were selected. We compared these words in a group of 12 ND-patients suffering from right-hemispheric first-ever stroke with word stimuli containing no existing residual words. Finally, we tested whether the serially presented words are more sensitive for the diagnosis of ND than text reading. The severity of ND was modulated strongly by the ND-test words and error frequencies in single word reading of ND words were on average more than 10 times higher than in a standardized text reading test (19.8% vs. 1.8%). The novel ND-test maximizes the frequency of specific ND-errors and is therefore more sensitive for the assessment of ND than conventional text reading tasks. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  20. [Profile of sensitization to allergens in children with atopic dermatitis assisting to Allergology Service of University Hospital, Nuevo Leon, Mexico].

    PubMed

    Yong-Rodríguez, Adrián; Macías-Weinmann, Alejandra; Palma-Gómez, Samuel; Arias-Cruz, Alfredo; Pérez-Vanzzini, Rafael; Gutiérrez-Mujica, José Julio; González-Díaz, Sandra Nora

    2015-01-01

    Sensitization to allergens in atopic dermatitis patients is a risk factor for developing asthma and allergic rhinitis in the future,as well as an aggravating factor in the course of the disease. Recent studies have attributed the activity of the proteases of some antigens to cause a grater defect in the epithelial barrier and a more severe disease. To know the sensitization to allergens pattern in children with atopic dermatitis attended at Allergology Service of University Hospital of UANL, Mexico, and to know if these children have higher sensitization to antigens with proteolytic activity. A retrospective study was done reviewing the skin prick test reports done in our service to children ranging from 5 months to 16 years old, diagnosed with atopic dermatitis during a period of 2 years, from January 2012 to January 2014. The frequency of sensitization to aeroallergens and food were analyzed as well as the weal size (≥6mm) on the skin in response to each particular allergen in the case of food skin prick test. Reports of skin tests of 66 children, 30 boys and 36 girls, were included; 37 of children were sensitized to more than one allergen,18/66 had asthma and/or allergic rhinitis, 40/66 60% skin prick tests were positive to high activity protease aeroallergens (Dermatophagoides pteronyssinus/Dermatophagoides farinae). Regarding food, sensitization was seen in 38 children; fruits and vegetables were the two most common foods. Only seven children had skin prick weal bigger than 6 mm, mainly to egg, fish and cow's milk. Children with atopic dermatitis are often sensitized to high protease activity aeroallergens, polysensitization is very common and the association with airway allergy is seen early in life. Sensitization to food is also common in these patients, but only a small percentage showed a response large enough to be associated with disease severity.

  1. External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil.

    PubMed

    Fischer, Carlo; Pedroso, Celia; Mendrone, Alfredo; Bispo de Filippis, Ana Maria; Vallinoto, Antonio Carlos Rosário; Ribeiro, Bergmann Morais; Durigon, Edison Luiz; Marques, Ernesto T A; Campos, Gubio S; Viana, Isabelle F T; Levi, José Eduardo; Scarpelli, Luciano Cesar; Nogueira, Mauricio Lacerda; Bastos, Michele de Souza; Souza, Nathalia C Santiago; Khouri, Ricardo; Lira, Sanny; Komninakis, Shirley Vasconcelos; Baronti, Cécile; Charrel, Rémi N; Kümmerer, Beate M; Drosten, Christian; Brites, Carlos; de Lamballerie, Xavier; Niedrig, Matthias; Netto, Eduardo Martins; Drexler, Jan Felix

    2018-05-01

    We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is needed to adequately estimate risk for Zika virus-associated disease and determine patient care.

  2. Aspartame sensitivity? A double blind randomised crossover study.

    PubMed

    Sathyapalan, Thozhukat; Thatcher, Natalie J; Hammersley, Richard; Rigby, Alan S; Courts, Fraser L; Pechlivanis, Alexandros; Gooderham, Nigel J; Holmes, Elaine; le Roux, Carel W; Atkin, Stephen L

    2015-01-01

    Aspartame is a commonly used intense artificial sweetener, being approximately 200 times sweeter than sucrose. There have been concerns over aspartame since approval in the 1980s including a large anecdotal database reporting severe symptoms. The objective of this study was to compare the acute symptom effects of aspartame to a control preparation. This was a double-blind randomized cross over study conducted in a clinical research unit in United Kingdom. Forty-eight individual who has self reported sensitivity to aspartame were compared to 48 age and gender matched aspartame non-sensitive individuals. They were given aspartame (100mg)-containing or control snack bars randomly at least 7 days apart. The main outcome measures were acute effects of aspartame measured using repeated ratings of 14 symptoms, biochemistry and metabonomics. Aspartame sensitive and non-sensitive participants differed psychologically at baseline in handling feelings and perceived stress. Sensitive participants had higher triglycerides (2.05 ± 1.44 vs. 1.26 ± 0.84mmol/L; p value 0.008) and lower HDL-C (1.16 ± 0.34 vs. 1.35 ± 0.54 mmol/L; p value 0.04), reflected in 1H NMR serum analysis that showed differences in the baseline lipid content between the two groups. Urine metabonomic studies showed no significant differences. None of the rated symptoms differed between aspartame and control bars, or between sensitive and control participants. However, aspartame sensitive participants rated more symptoms particularly in the first test session, whether this was placebo or control. Aspartame and control bars affected GLP-1, GIP, tyrosine and phenylalanine levels equally in both aspartame sensitive and non-sensitive subjects. Using a comprehensive battery of psychological tests, biochemistry and state of the art metabonomics there was no evidence of any acute adverse responses to aspartame. This independent study gives reassurance to both regulatory bodies and the public that acute ingestion of aspartame does not have any detectable psychological or metabolic effects in humans. ISRCTN Registry ISRCTN39650237.

  3. The "3 in 1" Study: Pooling Self-Taken Pharyngeal, Urethral, and Rectal Samples into a Single Sample for Analysis for Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in Men Who Have Sex with Men.

    PubMed

    Sultan, B; White, J A; Fish, R; Carrick, G; Brima, N; Copas, A; Robinson, A; Gilson, R; Mercey, D; Benn, P

    2016-03-01

    Triple-site testing (using pharyngeal, rectal, and urethral/first-void urine samples) for Neisseria gonorrhoeae and Chlamydia trachomatis using nucleic acid amplification tests detects greater numbers of infections among men who have sex with men (MSM). However, triple-site testing represents a cost pressure for services. MSM over 18 years of age were eligible if they requested testing for sexually transmitted infections (STIs), reported recent sexual contact with either C. trachomatis or N. gonorrhoeae, or had symptoms of an STI. Each patient underwent standard-of-care (SOC) triple-site testing, and swabs were taken to form a pooled sample (PS) (pharyngeal, rectal, and urine specimens). The PS was created using two methods during different periods at one clinic, but we analyzed the data in combination because the sensitivity of the two methods did not differ significantly for C. trachomatis (P = 0.774) or N. gonorrhoeae (P = 0.163). The sensitivity of PS testing (92%) was slightly lower than that of SOC testing (96%) for detecting C. trachomatis (P = 0.167). For N. gonorrhoeae, the sensitivity of PS testing (90%) was significantly lower than that of SOC testing (99%) (P < 0.001). When pharynx-only infections were excluded, the sensitivity of PS testing to detect N. gonorrhoeae infections increased to 94%. Our findings show that pooling of self-taken samples could be an effective and cost-saving method, with high negative predictive values. (Interim results of this study were presented at the BASHH 2013 summer meeting.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  4. Reveal Listeria 2.0 test for detection of Listeria spp. in foods and environmental samples.

    PubMed

    Alles, Susan; Curry, Stephanie; Almy, David; Jagadeesan, Balamurugan; Rice, Jennifer; Mozola, Mark

    2012-01-01

    A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.

  5. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    NASA Technical Reports Server (NTRS)

    Trout, Dawn; Burford, Janessa

    2012-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite . a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  6. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Burford, Janessa

    2013-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  7. Overview of biomarkers for diagnosis and monitoring of celiac disease.

    PubMed

    Brusca, Ignazio

    2015-01-01

    Among the adverse reactions caused by wheat, celiac disease (CD) is the longest studied and best-known pathology. The more recently defined non-celiac gluten sensitivity (NCGS) presents with symptoms which are often indistinguishable from CD. Diagnosis of CD is based on serologic, molecular, and bioptic testing. The IgA anti-transglutaminase (tTG) test is considered highly important, as it shows high sensitivity and specificity and its levels correlate to the degree of intestinal damage. Small bowel biopsy can be avoided in symptomatic patients with IgA anti-tTG levels above 10× the manufacturer's cut-off. Recently, tests of anti-deamidated peptides of gliadin (DGP) have replaced classic anti-native gliadin (AGA) tests. DGP assays have a considerably higher diagnostic accuracy than AGA assays, especially in the IgG class, and can replace anti-tTG tests in patients with selective IgA deficiency. The combination of IgG anti-DGP plus IgA anti-tTG assays show greater sensitivity than a single test, with very high specificity. EMA tests have great diagnostic accuracy but are not recommended by all the latest guidelines because they are observer dependent. Biopsy must still be considered the gold standard for CD diagnosis. HLA-DQ genotyping can be used to screen asymptomatic children and in cases of histology/serology disagreement. About half of NCGS patients are DQ2 positive and have IgG AGA. To diagnose NCGS, first CD and wheat allergy must be excluded; then the wheat dependence of symptoms must be verified by a gluten-free diet and subsequent gluten challenge. © 2015 Elsevier Inc. All rights reserved.

  8. Analytic and Clinical Performance of cobas HPV Testing in Anal Specimens from HIV-Positive Men Who Have Sex with Men

    PubMed Central

    Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V.; Chen, Jie; Lorey, Thomas S.; Gage, Julia C.; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M.; Castle, Philip E.

    2014-01-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (Ptrend < 0.001), HPV18 (Ptrend = 0.07), and other carcinogenic types (Ptrend < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. PMID:24899025

  9. Different sensitization to storage mites depending on the co-exposure to house dust mites.

    PubMed

    Morales, María; Iraola, Victor; Leonor, José Ramón; Bartra, Joan; Rodríguez, Fernando; Boquete, Manuel; Huertas, Ángel Julio; Paniagua, María Josefa; Pinto, Helder; Carnés, Jerónimo

    2015-01-01

    Co-sensitization to house dust mites (HDMs) and storage mites (SMs) is very frequent, although the clinical relevance is not well established. To describe the pattern of sensitization and immunologic characterization of patients with positive skin prick test reactions to HDMs and SMs in 4 areas of Spain, selected according to high exposure to HDMs and variable exposure to SMs. One hundred sixty-nine individuals with positive skin prick test reactions to HDMs and SMs were included. Specific IgE levels to different mite species and to Der p 1, Der p 2, and Der p 10 were determined. Immunoblots to Dermatophagoides pteronyssinus, Lepidoglyphus destructor, and Tyrophagus putrescentiae extracts were carried out, and allergograms were obtained. Results of different areas were compared. A high rate of polysensitization to SMs was observed, although 12% of participants did not have specific IgE to any SM species. Sensitization to Dermatophagoides species, Der p 2, and L destructor were predominant, although significant differences were observed among areas depending on the grade of exposure to SMs. In areas with high exposure, the SM allergogram showed greater recognition of group 2 allergen. Sensitization patterns to SMs in patients sensitized to HDMs and SMs differ depending on the exposure to SMs. Sensitization, mainly to L destructor, seems to exist in areas with high exposure, possibly with group 2 allergens mainly involved. However, in areas with low SM populations, sensitizations observed by skin prick testing appear to be related to HDM exposure. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  10. Development of LLNA:DAE: a new local lymph node assay that includes the elicitation phase, discriminates borderline-positive chemicals, and is useful for cross-sensitization testing.

    PubMed

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2014-02-01

    We developed a new local lymph node assay (LLNA) that includes the elicitation phase termed LLNA:DAE for discrimination of borderline-positive chemicals as classified by the LLNA modified by Daicel based on ATP content (LLNA:DA) and for cross-sensitization testing. Although the LLNA:DA method could help identify skin sensitizers, some skin irritants classified as non-sensitizers by the LLNA were classified as borderline positive. In addition, the evaluation for the cross-sensitization potential between chemicals was impossible. In the LLNA:DAE procedure, test group of mice received four applications of chemicals on the dorsum of the right ear for induction and one application on the dorsum of the left ear for elicitation. Control group of mice received one chemical application on the dorsum of the left ear. We evaluated the sensitizing potential by comparing the weights of the lymph nodes from the left ears between the two groups. The results of using the LLNA:DAE method to examine 24 chemicals, which contained borderline-positive chemicals, were consistent with those from the LLNA method, except for nickel chloride (NiCl2). Two chemical pairs, 2,4-dinitrochlorobenzene (DNCB) with 2,4-dinitrofluorobenzene (DNFB) and hydroquinone (HQ) with p-benzoquinone (p-BQ), showed clear cross-sensitization with each other, while another chemical pair, DNFB with hexylcinnamic aldehyde (HCA) did not. Taken together, our results suggest that the LLNA:DAE method is useful for discriminating borderline-positive chemicals and for determining chemical cross-sensitization.

  11. Expression of surface markers on the human monocytic leukaemia cell line, THP-1, as indicators for the sensitizing potential of chemicals.

    PubMed

    An, Susun; Kim, Seoyoung; Huh, Yong; Lee, Tae Ryong; Kim, Han-Kon; Park, Kui-Lea; Eun, Hee Chul

    2009-04-01

    Evaluation of skin sensitization potential is an important part of the safety assessment of cosmetic ingredients and topical drugs. Recently, evaluation of changes in surface marker expression induced in dendritic cells (DC) or DC surrogate cell lines following exposure to chemicals represents one approach for in vitro test methods. The study aimed to test the change of expression patterns of surface markers on THP-1 cells by chemicals as a predictive in vitro method for contact sensitization. We investigated the expression of CD54, CD86, CD83, CD80, and CD40 after a 1-day exposure to sensitizers (1-chloro-2,4-dinitrobenzene; 2,4-dinitrofluorobenzene; benzocaine; 5-chloro-2-methyl-4-isothiazolin-3-one; hexyl cinnamic aldehyde; eugenol; nickel sulfate hexahydrate; potassium dichromate; cobalt sulfate; 2-mercaptobenzothiazole; and ammonium tetrachloroplatinate) and non-sensitizers (sodium lauryl sulfate, benzalkonium chloride, lactic acid, salicylic acid, isopropanol, and dimethyl sulphoxide). The test concentrations were 0.1x, 0.5x, and 1x of the 50% inhibitory concentration, and the relative fluorescence intensity was used as an expression indicator. By evaluating the expression patterns of CD54, CD86, and CD40, we could classify the chemicals as sensitizers or non-sensitizers, but CD80 and CD83 showed non-specific patterns of expression. These data suggest that the THP-1 cells are good model for screening contact sensitizers and CD40 could be a useful marker complementary to CD54 and CD86.

  12. GTA weld cracking-alloy 625 to 304L

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, R.A.; Milewski, J.O.

    1985-08-01

    Autogenous gas tungsten arc welds joining alloy 625 and 304L stainless steel were found to be susceptible to weld solidification cracking. Utilization of pulsed current GTA welding produced a higher sensitivity to solidification cracks than continuous current welding. Spot Varestraint tests show that the sensitivity of this dissimilar metal combination to cracking exists over the entire range of dilutions while the greatest sensitivity is in 304L stainless steel rich compositions. Auger electron spectroscopy indicates that segregation of sulfur and phosphorous to the interdendritic phase promotes the hot cracking.

  13. Primary screening for cervical cancer based on high-risk human papillomavirus (HPV) detection and HPV 16 and HPV 18 genotyping, in comparison to cytology.

    PubMed

    Agorastos, Theodoros; Chatzistamatiou, Kimon; Katsamagkas, Taxiarchis; Koliopoulos, George; Daponte, Alexandros; Constantinidis, Theocharis; Constantinidis, Theodoros C

    2015-01-01

    The objective of the present study is to assess the performance of a high-risk human papillomavirus (HR-HPV) DNA test with individual HPV-16/HPV-18 genotyping as a method for primary cervical cancer screening compared with liquid-based cytology (LBC) in a population of Greek women taking part in routine cervical cancer screening. The study, conducted by the "HEllenic Real life Multicentric cErvical Screening" (HERMES) study group, involved the recruitment of 4,009 women, aged 25-55, who took part in routine cervical screening at nine Gynecology Departments in Greece. At first visit cervical specimens were collected for LBC and HPV testing using the Roche Cobas 4800 system. Women found positive for either cytology or HPV were referred for colposcopy, whereas women negative for both tests will be retested after three years. The study is ongoing and the results of the first screening round are reported herein. Valid results for cytology and HPV testing were obtained for 3,993 women. The overall prevalence of HR-HPV was 12.7%, of HPV-16 2.7% and of HPV-18 1.4%. Of those referred for colposcopy, cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was detected in 41 women (1.07%). At the threshold of CIN2+, cytology [atypical squamous cells of undetermined significance (ASC-US) or worse] and HPV testing showed a sensitivity of 53.7% and 100% respectively, without change between age groups. Cytology and HPV testing showed specificity of 96.8% and 90.3% respectively, which was increased in older women (≥30) in comparison to younger ones (25-29). Genotyping for HPV16/18 had similar accuracy to cytology for the detection of CIN2+ (sensitivity: 58.5%; specificity 97.5%) as well as for triage to colposcopy (sensitivity: 58.5% vs 53.7% for cytology). HPV testing has much better sensitivity than cytology to identify high-grade cervical lesions with slightly lower specificity. HPV testing with individual HPV-16/HPV-18 genotyping could represent a more accurate methodology for primary cervical cancer screening in comparison to liquid-based cytology, especially in older women.

  14. Learning effect and test-retest variability of pulsar perimetry.

    PubMed

    Salvetat, Maria Letizia; Zeppieri, Marco; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Brusini, Paolo

    2013-03-01

    To assess Pulsar Perimetry learning effect and test-retest variability (TRV) in normal (NORM), ocular hypertension (OHT), glaucomatous optic neuropathy (GON), and primary open-angle glaucoma (POAG) eyes. This multicenter prospective study included 43 NORM, 38 OHT, 33 GON, and 36 POAG patients. All patients underwent standard automated perimetry and Pulsar Contrast Perimetry using white stimuli modulated in phase and counterphase at 30 Hz (CP-T30W test). The learning effect and TRV for Pulsar Perimetry were assessed for 3 consecutive visual fields (VFs). The learning effect were evaluated by comparing results from the first session with the other 2. TRV was assessed by calculating the mean of the differences (in absolute value) between retests for each combination of single tests. TRV was calculated for Mean Sensitivity, Mean Defect, and single Mean Sensitivity for each 66 test locations. Influence of age, VF eccentricity, and loss severity on TRV were assessed using linear regression analysis and analysis of variance. The learning effect was not significant in any group (analysis of variance, P>0.05). TRV for Mean Sensitivity and Mean Defect was significantly lower in NORM and OHT (0.6 ± 0.5 spatial resolution contrast units) than in GON and POAG (0.9 ± 0.5 and 1.0 ± 0.8 spatial resolution contrast units, respectively) (Kruskal-Wallis test, P=0.04); however, the differences in NORM among age groups was not significant (Kruskal-Wallis test, P>0.05). Slight significant differences were found for the single Mean Sensitivity TRV among single locations (Duncan test, P<0.05). For POAG, TRV significantly increased with decreasing Mean Sensitivity and increasing Mean Defect (linear regression analysis, P<0.01). The Pulsar Perimetry CP-T30W test did not show significant learning effect in patients with standard automated perimetry experience. TRV for global indices was generally low, and was not related to patient age; it was only slightly affected by VF defect eccentricity, and significantly influenced by VF loss severity.

  15. ISFET pH Sensitivity: Counter-Ions Play a Key Role.

    PubMed

    Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip

    2017-02-02

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.

  16. ISFET pH Sensitivity: Counter-Ions Play a Key Role

    PubMed Central

    Parizi, Kokab B.; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H. S. Philip

    2017-01-01

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor. PMID:28150700

  17. NP-59 test for preoperative localization of primary hyperaldosteronism.

    PubMed

    Di Martino, Marcello; García Sanz, Iñigo; Muñoz de Nova, Jose Luis; Marín Campos, Cristina; Martínez Martín, Miguel; Domínguez Gadea, Luis

    2017-03-01

    Adrenal venous sampling is generally considered the gold standard to identify unilateral hormone production in cases of primary hyperaldosteronism. The aim of this study is to evaluate whether the iodine-131-6-β-iodomethyl-19-norcholesterol (NP-59) test may represent an alternative in selected cases. Patients submitted to laparoscopic adrenalectomy for suspected primary hyperaldosteronism (n = 27) were retrospectively reviewed. When nuclear medicine tests were preoperatively performed, their results were compared with the histopathologic findings and clinical improvement. Nuclear medicine tests were realized in 13 patients. In 11 (84.6%), a planar anterior and posterior NP-59 scintigraphy was performed and a SPECT/TC in two (15.4%). Scintigraphy indicated a preoperative lateralization in 12 out of 13 patients (92.3%). When the value of NP-59 tests was based on pathologic results, it showed a sensitivity of 90.9% and a positive predictive value of 83.3%. When the nuclear medicine test's performance was based on postoperative blood pressure control, both sensitivity and positive predictive value were 91.6%. Nuclear medicine tests represent a useful tool in the preoperative localisation of primary hyperaldosteronism with a high sensitivity and positive predictive value. In patients with contraindications to adrenal venous sampling like contrast allergies, or when it is inconclusive, scintigraphy can represent a useful and non-invasive alternative.

  18. Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China

    PubMed Central

    Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan

    2015-01-01

    Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582

  19. Nested polymerase chain reaction on blood clots for gene encoding 56 kDa antigen and serology for the diagnosis of scrub typhus.

    PubMed

    Prakash, J A J; Kavitha, M L; Mathai, E

    2011-01-01

    Scrub typhus is a zoonotic illness endemic in the Asia-Pacific region. Early diagnosis and appropriate management contribute significantly to preventing adverse outcomes including mortality. Serology is widely used for diagnosing scrub typhus. Recent reports suggest that polymerase chain reaction (PCR) could be a rapid and reliable alternative. This study assessed the utility of these tests for scrub typhus diagnosis. Nested PCR to detect the 56 kDa antigen gene of O. tsutsugamushi was performed on blood clots from 87 individuals with clinically suspected scrub typhus. Weil-Felix test and scrub typhus IgM ELISA were performed on serum samples from the same patients. As a gold standard reference test was not available, latent class analysis (LCA) was used to assess the performance of the three tests. The LCA analysis showed the sensitivity of Weil-Felix test, IgM ELISA and PCR to be 59%, 100% and 58% respectively. The specificity of ELISA was only 73%, whereas those of the Weil-Felix test and PCR were 94% and 100% respectively. Nested PCR using blood clots while specific, lacked sensitivity as compared to IgM ELISA. In resource-poor settings Weil-Felix test still remains valuable despite its moderate sensitivity.

  20. Comparison of an Ampelisca abdita growth rate test with other standard amphipod sediment toxicity tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafer, K.; Weston, D.P.

    1995-12-31

    Amphipod crustaceans are often used to measure the toxicity of bulk sediments. Acute lethal bioassays are commonly employed, but this study investigated the potential for using a chronic growth bioassay with Ampelisca abdita. A potential advantage of this method is that the growth rate could be a more sensitive measure of contamination than mortality. Growth rates for A. abdita in sediments spiked with cadmium and crude oil were compared to mortality rates in A. abdita, Eohaustorius estuaries, and Rhepoxynius abronius in sediments with the same concentrations of contaminants. A. abdita was more sensitive to cadmium than the other two species.more » For crude oil, there was a significant shift in size distribution from the control even at concentrations as low as 150 mg/kg of oil. The standard acute lethal tests for all species, on the other hand, did not show significant mortality until at least 1,600 mg/kg. The results confirm that growth rates are a more sensitive indicator of toxicity, and to at least the three contaminants tested, A. abdita is as sensitive as E. estuarius and R. abronius. This study also confirmed the reported high mortality rates of E. estuaries in San Francisco Bay sediments. The causes of this high mortality are unknown but give further reason for using A. abdita for toxicity tests in this region.« less

  1. Brain imaging of pain sensitization in patients with knee osteoarthritis.

    PubMed

    Pujol, Jesus; Martínez-Vilavella, Gerard; Llorente-Onaindia, Jone; Harrison, Ben J; López-Solà, Marina; López-Ruiz, Marina; Blanco-Hinojo, Laura; Benito, Pere; Deus, Joan; Monfort, Jordi

    2017-09-01

    A relevant aspect in osteoarthritic pain is neural sensitization. This phenomenon involves augmented responsiveness to painful stimulation and may entail a clinically worse prognosis. We used functional magnetic resonance imaging (fMRI) to study pain sensitization in patients with knee osteoarthritis. Sixty patients were recruited and pain sensitization was clinically defined on the basis of regional spreading of pain (spreading sensitization) and increased pain response to repeated stimulation (temporal summation). Functional magnetic resonance imaging testing involved assessing brain responses to both pressure and heat stimulation. Thirty-three patients (55%) showed regional pain spreading (simple sensitization) and 19 patients (32%) showed both regional spreading and temporal summation. Sensitized patients were more commonly women. Direct painful pressure stimulation of the joint (articular interline) robustly activated all of the neural elements typically involved in pain perception, but did not differentiate sensitized and nonsensitized patients. Painful pressure stimulation on the anterior tibial surface (sensitized site) evoked greater activation in sensitized patients in regions typically involved in pain and also beyond these regions, extending to the auditory, visual, and ventral sensorimotor cortices. Painful heat stimulation of the volar forearm did not discriminate the sensitization phenomenon. Results confirm the high prevalence of pain sensitization secondary to knee osteoarthritis. Relevantly, the sensitization phenomenon was associated with neural changes extending beyond strict pain-processing regions with enhancement of activity in general sensory, nonnociceptive brain areas. This effect is in contrast to the changes previously identified in primary pain sensitization in fibromyalgia patients presenting with a weakening of the general sensory integration.

  2. A comparison of bivariate, multivariate random-effects, and Poisson correlated gamma-frailty models to meta-analyze individual patient data of ordinal scale diagnostic tests.

    PubMed

    Simoneau, Gabrielle; Levis, Brooke; Cuijpers, Pim; Ioannidis, John P A; Patten, Scott B; Shrier, Ian; Bombardier, Charles H; de Lima Osório, Flavia; Fann, Jesse R; Gjerdingen, Dwenda; Lamers, Femke; Lotrakul, Manote; Löwe, Bernd; Shaaban, Juwita; Stafford, Lesley; van Weert, Henk C P M; Whooley, Mary A; Wittkampf, Karin A; Yeung, Albert S; Thombs, Brett D; Benedetti, Andrea

    2017-11-01

    Individual patient data (IPD) meta-analyses are increasingly common in the literature. In the context of estimating the diagnostic accuracy of ordinal or semi-continuous scale tests, sensitivity and specificity are often reported for a given threshold or a small set of thresholds, and a meta-analysis is conducted via a bivariate approach to account for their correlation. When IPD are available, sensitivity and specificity can be pooled for every possible threshold. Our objective was to compare the bivariate approach, which can be applied separately at every threshold, to two multivariate methods: the ordinal multivariate random-effects model and the Poisson correlated gamma-frailty model. Our comparison was empirical, using IPD from 13 studies that evaluated the diagnostic accuracy of the 9-item Patient Health Questionnaire depression screening tool, and included simulations. The empirical comparison showed that the implementation of the two multivariate methods is more laborious in terms of computational time and sensitivity to user-supplied values compared to the bivariate approach. Simulations showed that ignoring the within-study correlation of sensitivity and specificity across thresholds did not worsen inferences with the bivariate approach compared to the Poisson model. The ordinal approach was not suitable for simulations because the model was highly sensitive to user-supplied starting values. We tentatively recommend the bivariate approach rather than more complex multivariate methods for IPD diagnostic accuracy meta-analyses of ordinal scale tests, although the limited type of diagnostic data considered in the simulation study restricts the generalization of our findings. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Distributed Evaluation of Local Sensitivity Analysis (DELSA), with application to hydrologic models

    USGS Publications Warehouse

    Rakovec, O.; Hill, Mary C.; Clark, M.P.; Weerts, A. H.; Teuling, A. J.; Uijlenhoet, R.

    2014-01-01

    This paper presents a hybrid local-global sensitivity analysis method termed the Distributed Evaluation of Local Sensitivity Analysis (DELSA), which is used here to identify important and unimportant parameters and evaluate how model parameter importance changes as parameter values change. DELSA uses derivative-based “local” methods to obtain the distribution of parameter sensitivity across the parameter space, which promotes consideration of sensitivity analysis results in the context of simulated dynamics. This work presents DELSA, discusses how it relates to existing methods, and uses two hydrologic test cases to compare its performance with the popular global, variance-based Sobol' method. The first test case is a simple nonlinear reservoir model with two parameters. The second test case involves five alternative “bucket-style” hydrologic models with up to 14 parameters applied to a medium-sized catchment (200 km2) in the Belgian Ardennes. Results show that in both examples, Sobol' and DELSA identify similar important and unimportant parameters, with DELSA enabling more detailed insight at much lower computational cost. For example, in the real-world problem the time delay in runoff is the most important parameter in all models, but DELSA shows that for about 20% of parameter sets it is not important at all and alternative mechanisms and parameters dominate. Moreover, the time delay was identified as important in regions producing poor model fits, whereas other parameters were identified as more important in regions of the parameter space producing better model fits. The ability to understand how parameter importance varies through parameter space is critical to inform decisions about, for example, additional data collection and model development. The ability to perform such analyses with modest computational requirements provides exciting opportunities to evaluate complicated models as well as many alternative models.

  4. The relationship of ethics education to moral sensitivity and moral reasoning skills of nursing students.

    PubMed

    Park, Mihyun; Kjervik, Diane; Crandell, Jamie; Oermann, Marilyn H

    2012-07-01

    This study described the relationships between academic class and student moral sensitivity and reasoning and between curriculum design components for ethics education and student moral sensitivity and reasoning. The data were collected from freshman (n = 506) and senior students (n = 440) in eight baccalaureate nursing programs in South Korea by survey; the survey consisted of the Korean Moral Sensitivity Questionnaire and the Korean Defining Issues Test. The results showed that moral sensitivity scores in patient-oriented care and conflict were higher in senior students than in freshman students. Furthermore, more hours of ethics content were associated with higher principled thinking scores of senior students. Nursing education in South Korea may have an impact on developing student moral sensitivity. Planned ethics content in nursing curricula is necessary to improve moral sensitivity and moral reasoning of students.

  5. Setup for testing cameras for image guided surgery using a controlled NIR fluorescence mimicking light source and tissue phantom

    NASA Astrophysics Data System (ADS)

    Georgiou, Giota; Verdaasdonk, Rudolf M.; van der Veen, Albert; Klaessens, John H.

    2017-02-01

    In the development of new near-infrared (NIR) fluorescence dyes for image guided surgery, there is a need for new NIR sensitive camera systems that can easily be adjusted to specific wavelength ranges in contrast the present clinical systems that are only optimized for ICG. To test alternative camera systems, a setup was developed to mimic the fluorescence light in a tissue phantom to measure the sensitivity and resolution. Selected narrow band NIR LED's were used to illuminate a 6mm diameter circular diffuse plate to create uniform intensity controllable light spot (μW-mW) as target/source for NIR camera's. Layers of (artificial) tissue with controlled thickness could be placed on the spot to mimic a fluorescent `cancer' embedded in tissue. This setup was used to compare a range of NIR sensitive consumer's cameras for potential use in image guided surgery. The image of the spot obtained with the cameras was captured and analyzed using ImageJ software. Enhanced CCD night vision cameras were the most sensitive capable of showing intensities < 1 μW through 5 mm of tissue. However, there was no control over the automatic gain and hence noise level. NIR sensitive DSLR cameras proved relative less sensitive but could be fully manually controlled as to gain (ISO 25600) and exposure time and are therefore preferred for a clinical setting in combination with Wi-Fi remote control. The NIR fluorescence testing setup proved to be useful for camera testing and can be used for development and quality control of new NIR fluorescence guided surgery equipment.

  6. Diagnostic Value of Facial Nerve Antidromic Evoked Potential in Patients With Bell's Palsy: A Preliminary Study

    PubMed Central

    Lee, Ji Hoon; Kim, Sun Mi; Yang, Hea Eun; Lee, Jang Woo

    2014-01-01

    Objective To assess the practical diagnostic value of facial nerve antidromic evoked potential (FNAEP), we compared it with the diagnostic value of the electroneurography (ENoG) test in Bell's palsy. Methods In total, 20 patients with unilateral Bell's palsy were recruited. Between the 1st and 17th days after the onset of facial palsy, FNAEP and ENoG tests were conducted. The degeneration ratio and FNAEP latency difference between the affected and unaffected sides were calculated in all subjects. Results In all patients, FNAEP showed prolonged latencies on the affected side versus the unaffected side. The difference was statistically significant. In contrast, there was no significant difference between sides in the normal control group. In 8 of 20 patients, ENoG revealed a degeneration ratio less than 50%, but FNAEP show a difference of more than 0.295±0.599 ms, the average value of normal control group. This shows FNAEP could be a more sensitive test for Bell's palsy diagnosis than ENoG. In particular, in 10 patients tested within 7 days after onset, an abnormal ENoG finding was noted in only four of them, but FNAEP showed a significant latency difference in all patients at this early stage. Thus, FANEP was more sensitive in detecting facial nerve injury than the ENoG test (p=0.031). Conclusion FNAEP has some clinical value in the diagnosis of facial nerve degeneration. It is important that FNAEP be considered in patients with facial palsy at an early stage and integrated with other relevant tests. PMID:25024963

  7. Development of aquatic life criteria for triclosan and comparison of the sensitivity between native and non-native species.

    PubMed

    Wang, Xiao-Nan; Liu, Zheng-Tao; Yan, Zhen-Guang; Zhang, Cong; Wang, Wei-Li; Zhou, Jun-Li; Pei, Shu-Wei

    2013-09-15

    Triclosan (TCS) is an antimicrobial agent which is used as a broad-spectrum bacteriostatic and found in personal care products, and due to this it is widely spread in the aquatic environment. However, there is no paper dealing with the aquatic life criteria of TCS, mainly result from the shortage of toxicity data of different taxonomic levels. In the present study, toxicity data were obtained from 9 acute toxicity tests and 3 chronic toxicity tests using 9 Chinese native aquatic species from different taxonomic levels, and the aquatic life criteria was derived using 3 methods. Furthermore, differences of species sensitivity distributions (SSD) between native and non-native species were compared. Among the tested species, demersal fish Misgurnus anguillicaudatus was the most sensitive species, and the fishes were more sensitive than the aquatic invertebrates of Annelid and insect, and the insect was the least sensitive species. The comparison showed that there was no significant difference between SSDs constructed from native and non-native taxa. Finally, a criterion maximum concentration of 0.009 mg/L and a criterion continuous concentration of 0.002 mg/L were developed based on different taxa, according to the U.S. Environmental Protection Agency guidelines. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development and evaluation of flow through assay for detection of antibodies against porcine cysticercosis.

    PubMed

    Sreedevi, C; Hafeez, Md; Subramanyam, K V; Anand Kumar, P; Chengalva Rayulu, V

    2011-04-01

    A flow through assay (FTA) was developed on cellulose acetate membrane for the serodiagnosis of porcine cysticercosis using cyst fluid (CFA) and whole cyst antigens (WCA) of Taenia solium metacestode. The assay consisted of antigen of T. solium metacestode coated onto membrane, mounted on a flow-through test device to provide assay capture matrix. The optimum concentration of coating antigen was 250 ng. The protein A colloidal gold conjugate served as antigen-antibody detecting reagent. A total of 225 serum samples were tested using two antigens. Results were better with CFA (96.0% sensitivity; 96.0% specificity) compared to WCA (92.0% sensitivity; 96.0% specificity). The test was also compared with enzyme-linked immunosorbent assay. The ELISA showed 96 per cent sensitivity with both the antigens whereas; the specificity was 96 and 92 per cent with CFA and WCA respectively. The sensitivity and specificity of flow through assay agrees closely with those of the ELISA. The cross-reaction was observed in one out of eight hydatidosis positive pigs (12.5%) with CFA by both the assays. The highest diagnostic accuracy (96%) was obtained with CFA-FTA and CFA-ELISA. For its high sensitivity and sporadic cross-reactions, CFA-FTA appears to be suitable for practical use at field level without instrumentation.

  9. Identification of small-scale low and high permeability layers using single well forced-gradient tracer tests: fluorescent dye imaging and modelling at the laboratory-scale.

    PubMed

    Barns, Gareth L; Thornton, Steven F; Wilson, Ryan D

    2015-01-01

    Heterogeneity in aquifer permeability, which creates paths of varying mass flux and spatially complex contaminant plumes, can complicate the interpretation of contaminant fate and transport in groundwater. Identifying the location of high mass flux paths is critical for the reliable estimation of solute transport parameters and design of groundwater remediation schemes. Dipole flow tracer tests (DFTTs) and push-pull tests (PPTs) are single well forced-gradient tests which have been used at field-scale to estimate aquifer hydraulic and transport properties. In this study, the potential for PPTs and DFTTs to resolve the location of layered high- and low-permeability layers in granular porous media was investigated with a pseudo 2-D bench-scale aquifer model. Finite element fate and transport modelling was also undertaken to identify appropriate set-ups for in situ tests to determine the type, magnitude, location and extent of such layered permeability contrasts at the field-scale. The characteristics of flow patterns created during experiments were evaluated using fluorescent dye imaging and compared with the breakthrough behaviour of an inorganic conservative tracer. The experimental results show that tracer breakthrough during PPTs is not sensitive to minor permeability contrasts for conditions where there is no hydraulic gradient. In contrast, DFTTs are sensitive to the type and location of permeability contrasts in the host media and could potentially be used to establish the presence and location of high or low mass flux paths. Numerical modelling shows that the tracer peak breakthrough time and concentration in a DFTT is sensitive to the magnitude of the permeability contrast (defined as the permeability of the layer over the permeability of the bulk media) between values of 0.01-20. DFTTs are shown to be more sensitive to deducing variations in the contrast, location and size of aquifer layered permeability contrasts when a shorter central packer is used. However, larger packer sizes are more likely to be practical for field-scale applications, with fewer tests required to characterise a given aquifer section. The sensitivity of DFTTs to identify layered permeability contrasts was not affected by test flow rate. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

    PubMed

    Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick M M; Leeflang, Mariska M G

    2015-03-11

    Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.

  11. FY17 Status Report on Testing Supporting the Inclusion of Grade 91 Steel as an Acceptable Material for Application of the EPP Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Messner, Mark C.; Sham, Sam; Wang, Yanli

    This report summarizes the experiments performed in FY17 on Gr. 91 steels. The testing of Gr. 91 has technical significance because, currently, it is the only approved material for Class A construction that is strongly cyclic softening. Specific FY17 testing includes the following activities for Gr. 91 steel. First, two types of key feature testing have been initiated, including two-bar thermal ratcheting and Simplified Model Testing (SMT). The goal is to qualify the Elastic – Perfectly Plastic (EPP) design methodologies and to support incorporation of these rules for Gr. 91 into the ASME Division 5 Code. The preliminary SMT testmore » results show that Gr. 91 is most damaging when tested with compression hold mode under the SMT creep fatigue testing condition. Two-bar thermal ratcheting test results at a temperature range between 350 to 650o C were compared with the EPP strain limits code case evaluation, and the results show that the EPP strain limits code case is conservative. The material information obtained from these key feature tests can also be used to verify its material model. Second, to provide experimental data in support of the viscoplastic material model development at Argonne National Laboratory, selective tests were performed to evaluate the effect of cyclic softening on strain rate sensitivity and creep rates. The results show the prior cyclic loading history decreases the strain rate sensitivity and increases creep rates. In addition, isothermal cyclic stress-strain curves were generated at six different temperatures, and a nonisothermal thermomechanical testing was also performed to provide data to calibrate the viscoplastic material model.« less

  12. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy

    PubMed Central

    Devillé, Walter LJM; Yzermans, Joris C; van Duijn, Nico P; Bezemer, P Dick; van der Windt, Daniëlle AWM; Bouter, Lex M

    2004-01-01

    Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165) and elderly people (DOR = 108). Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276). Sensitivities were highest in family medicine (86%). Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52), in children (DOR = 46), and if clinical information was present (DOR = 28). Sensitivity was highest in studies carried out in family medicine (90%). Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary between 68 and 88% in different patient groups, but positive test results have to be confirmed. Although the combination of positive test results is very sensitive in family practice, the usefulness of the dipstick test alone to rule in infection remains doubtful, even with high pre-test probabilities. PMID:15175113

  13. Embedded performance validity tests within the Hopkins Verbal Learning Test - Revised and the Brief Visuospatial Memory Test - Revised.

    PubMed

    Sawyer, R John; Testa, S Marc; Dux, Moira

    2017-01-01

    Various research studies and neuropsychology practice organizations have reiterated the importance of developing embedded performance validity tests (PVTs) to detect potentially invalid neurocognitive test data. This study investigated whether measures within the Hopkins Verbal Learning Test - Revised (HVLT-R) and the Brief Visuospatial Memory Test - Revised (BVMT-R) could accurately classify individuals who fail two or more PVTs during routine clinical assessment. The present sample of 109 United States military veterans (Mean age = 52.4, SD = 13.3), all consisted of clinically referred patients and received a battery of neuropsychological tests. Based on performance validity findings, veterans were assigned to valid (n = 86) or invalid (n = 23) groups. Of the 109 patients in the overall sample, 77 were administered the HLVT-R and 75 were administered the BVMT-R, which were examined for classification accuracy. The HVLT-R Recognition Discrimination Index and the BVMT-R Retention Percentage showed good to adequate discrimination with an area under the curve of .78 and .70, respectively. The HVLT-R Recognition Discrimination Index showed sensitivity of .53 with specificity of .93. The BVMT-R Retention Percentage demonstrated sensitivity of .31 with specificity of .92. When used in conjunction with other PVTs, these new embedded PVTs may be effective in the detection of invalid test data, although they are not intended for use in patients with dementia.

  14. Recombinase Polymerase Amplification Compared to Real-Time Polymerase Chain Reaction Test for the Detection of Fasciola hepatica in Human Stool

    PubMed Central

    Cabada, Miguel M.; Malaga, Jose L.; Castellanos-Gonzalez, Alejandro; Bagwell, Kelli A.; Naeger, Patrick A.; Rogers, Hayley K.; Maharsi, Safa; Mbaka, Maryann; White, A. Clinton

    2017-01-01

    Fasciola hepatica is the most widely distributed trematode infection in the world. Control efforts may be hindered by the lack of diagnostic capacity especially in remote endemic areas. Polymerase chain reaction (PCR)–based methods offer high sensitivity and specificity but require expensive technology. However, the recombinase polymerase amplification (RPA) is an efficient isothermal method that eliminates the need for a thermal cycler and has a high deployment potential to resource-limited settings. We report on the characterization of RPA and PCR tests to detect Fasciola infection in clinical stool samples with low egg burdens. The sensitivity of the RPA and PCR were 87% and 66%, respectively. Both tests were 100% specific showing no cross-reactivity with trematode, cestode, or nematode parasites. In addition, RPA and PCR were able to detect 47% and 26% of infections not detected by microscopy, respectively. The RPA adapted to a lateral flow platform was more sensitive than gel-based detection of the reaction products. In conclusion, the Fasciola RPA is a highly sensitive and specific test to diagnose chronic infection using stool samples. The Fasciola RPA lateral flow has the potential for deployment to endemic areas after further characterization. PMID:27821691

  15. Intergranular Corrosion Behavior of 304LN Stainless Steel Heat Treated at 623 K (350 °C)

    NASA Astrophysics Data System (ADS)

    Singh, Raghuvir; Kumar, Mukesh; Ghosh, Mainak; Das, Gautam; Singh, P. K.; Chattoraj, I.

    2013-01-01

    Low temperature sensitization of 304LN stainless steel from the two pipes, differing slightly in chemical composition, has been investigated; specimens were aged at 623 K (350 °C) for 20,000 hours and evaluated for intergranular corrosion and degree of sensitization. The base and heat-affected zone (HAZ) of the 304LN-1 appear resistant to sensitization, while 304LN-2 revealed a "dual" type microstructure at the transverse section and HAZ. The microstructure at 5.0-mm distance from the fusion line indicates qualitatively less sensitization as compared to that at 2.0 mm. The 304LN-2 base alloy shows overall lower degree of sensitization values as compared to the 304LN-1. A similar trend of degree of sensitization was observed in the HAZ where it was higher in the 304LN-1 as compared to the 304LN-2. The weld zone of both the stainless steels suffered from cracking during ASTM A262 practice E, while the parent metals and HAZs did not show such fissures. A mottled image within the ferrite lamella showed spinodal decomposition. The practice E test and transmission electron microscopy results indicate that the interdendritic regions may suffer from failure due to carbide precipitation and due to the evolution of brittle phase from spinodal decomposition.

  16. Orthostatic Intolerance and Postural Orthostatic Tachycardia Syndrome in Joint Hypermobility Syndrome/Ehlers-Danlos Syndrome, Hypermobility Type: Neurovegetative Dysregulation or Autonomic Failure?

    PubMed

    Celletti, Claudia; Camerota, Filippo; Castori, Marco; Censi, Federica; Gioffrè, Laura; Calcagnini, Giovanni; Strano, Stefano

    2017-01-01

    Background . Joint hypermobility syndrome/Ehlers-Danlos syndrome, hypermobility type (JHS/EDS-HT), is a hereditary connective tissue disorder mainly characterized by generalized joint hypermobility, skin texture abnormalities, and visceral and vascular dysfunctions, also comprising symptoms of autonomic dysfunction. This study aims to further evaluate cardiovascular autonomic involvement in JHS/EDS-HT by a battery of functional tests. Methods . The response to cardiovascular reflex tests comprising deep breathing, Valsalva maneuver, 30/15 ratio, handgrip test, and head-up tilt test was studied in 35 JHS/EDS-HT adults. Heart rate and blood pressure variability was also investigated by spectral analysis in comparison to age and sex healthy matched group. Results . Valsalva ratio was normal in all patients, but 37.2% of them were not able to finish the test. At tilt, 48.6% patients showed postural orthostatic tachycardia, 31.4% orthostatic intolerance, 20% normal results. Only one patient had orthostatic hypotension. Spectral analysis showed significant higher baroreflex sensitivity values at rest compared to controls. Conclusions. This study confirms the abnormal cardiovascular autonomic profile in adults with JHS/EDS-HT and found the higher baroreflex sensitivity as a potential disease marker and clue for future research.

  17. Health effects from the inhalation of oxidant air pollutants as related to the immune system. Final report. Research report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osebold, J.W.; Zee, Y.C.

    1985-07-01

    The investigations dealt with links between ozone inhalation and lung diseases. Mice exposed to ozone both continuously and intermittently in four-day cycles showed allergic sensitization to the test antigen (ovalbumin) when compaired to mice maintained in ambeint air. An adjuvant (inactivated Bordetella pertussis cells) administered to mice augmented the immunological response to the test antigen with periodic exposure to ozone. Guinea pigs were tested for allergic sensitization from ozone exposure similar to human asthma, but this trial was not definitive. Ozone inhalation reduced the severity of pneumonia in mice from influenza virus infection, even when ozone and virus exposures weremore » timed to produce maximal edema in the lung.« less

  18. Direct observation of phase-sensitive Hong-Ou-Mandel interference

    NASA Astrophysics Data System (ADS)

    Marek, Petr; Zapletal, Petr; Filip, Radim; Hashimoto, Yosuke; Toyama, Takeshi; Yoshikawa, Jun-ichi; Makino, Kenzo; Furusawa, Akira

    2017-09-01

    The quality of individual photons and their ability to interfere are traditionally tested by measuring the Hong-Ou-Mandel photon bunching effect. However, this phase-insensitive measurement only tests the particle aspect of the quantum interference, leaving out the phase-sensitive aspects relevant for continuous-variable processing. To overcome these limitations we formulate a witness capable of recognizing both the indistinguishability of the single photons and their quality with regard to their continuous-variable utilization. We exploit the conditional nonclassical squeezing and show that it can reveal both the particle and the wave aspects of the quantum interference in a single set of direct measurements. We experimentally test the witness by applying it to a pair of independent single photons retrieved on demand.

  19. Sugar-sensitive neurone responses and sugar feeding preferences influence lifespan and biting behaviours of the Afrotropical malaria mosquito, Anopheles gambiae.

    PubMed

    Kessler, Sébastien; Vlimant, Michèle; Guerin, Patrick M

    2015-03-01

    Floral nectar is the main source of carbohydrates for many insects including mosquitoes. Nonetheless, the physiological mechanisms underlying feeding on carbohydrates by the Afrotropical malaria mosquito Anopheles gambiae remain poorly understood. Here, we tested whether sugar sensitivity and sugar feeding preferences correlate with longevity in A. gambiae. We also tested whether feeding females on different sugar diets influences their biting behaviours. Electrophysiological recordings show that sugar neurones on the labella of females are most sensitive to sucrose, mixtures of glucose and fructose, and to melezitose; other sugars tested, including glucose and fructose presented alone, only weakly activate these taste neurones. Mosquitoes survive longest on sucrose, the most preferred sugar. Whereas feeding on a mixture of glucose and fructose is preferred over fructose or glucose alone, fructose supports higher longevity than either glucose or the mixture of the two hexoses. Females that had previously fed on glucose show a stronger biting response than those fed on sucrose, perhaps in an effort to compensate for their lower energetic state. These findings contribute to our understanding of the physiological basis of sugar feeding in A. gambiae and indicate how the sugar diet can affect laboratory-reared A. gambiae biting behaviours.

  20. Comprehensive genetic testing for female and male infertility using next-generation sequencing.

    PubMed

    Patel, Bonny; Parets, Sasha; Akana, Matthew; Kellogg, Gregory; Jansen, Michael; Chang, Chihyu; Cai, Ying; Fox, Rebecca; Niknazar, Mohammad; Shraga, Roman; Hunter, Colby; Pollock, Andrew; Wisotzkey, Robert; Jaremko, Malgorzata; Bisignano, Alex; Puig, Oscar

    2018-05-19

    To develop a comprehensive genetic test for female and male infertility in support of medical decisions during assisted reproductive technology (ART) protocols. We developed a next-generation sequencing (NGS) gene panel consisting of 87 genes including promoters, 5' and 3' untranslated regions, exons, and selected introns. In addition, sex chromosome aneuploidies and Y chromosome microdeletions were analyzed concomitantly using the same panel. The NGS panel was analytically validated by retrospective analysis of 118 genomic DNA samples with known variants in loci representative of female and male infertility. Our results showed analytical accuracy of > 99%, with > 98% sensitivity for single-nucleotide variants (SNVs) and > 91% sensitivity for insertions/deletions (indels). Clinical sensitivity was assessed with samples containing variants representative of male and female infertility, and it was 100% for SNVs/indels, CFTR IVS8-5T variants, sex chromosome aneuploidies, and copy number variants (CNVs) and > 93% for Y chromosome microdeletions. Cost analysis shows potential savings when comparing this single NGS assay with the standard approach, which includes multiple assays. A single, comprehensive, NGS panel can simplify the ordering process for healthcare providers, reduce turnaround time, and lower the overall cost of testing for genetic assessment of infertility in females and males, while maintaining accuracy.

  1. Expanded Circulating Tumor Cells from a Patient with ALK-Positive Lung Cancer Present with EML4-ALK Rearrangement Along with Resistance Mutation and Enable Drug Sensitivity Testing: A Case Study.

    PubMed

    Zhang, Zhuo; Shiratsuchi, Hiroe; Palanisamy, Nallasivam; Nagrath, Sunitha; Ramnath, Nithya

    2017-02-01

    The emergence of liquid biopsy using circulating tumor cells (CTCs) as a resource to identify genomic alterations in cancer presents new opportunities for diagnosis, therapy, and surveillance. We identified EML4-ALK gene rearrangement in expanded CTCs from a patient with ALK-positive lung adenocarcinoma. At the time of radiographic progression, CTCs obtained from the patient revealed a drug resistance mutation (i.e., L1196M on the ALK gene). CTCs were expanded ex vivo and drug sensitivity testing was performed using two ALK inhibitors, crizotinib and ceritinib. The half maximal inhibitory concentration of ceritinib was 1664 nM compared with crizotinib (2268 nM), showing that ceritinib was a more potent ALK inhibitor. We show that it is feasible to detect serial genetic alterations in expanded CTCs and perform in vitro drug screening. These findings support the clinical utility of CTCs not only for diagnosis, but also a potential tool for drug sensitivity testing in distinct subsets of lung cancer and for personalized precision medicine. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  2. Contribution of a new electrophysiologic test to Morton's neuroma diagnosis.

    PubMed

    Pardal-Fernández, José Manuel; Palazón-García, Elena; Hernández-Fernández, Francisco; de Cabo, Carlos

    2014-06-01

    Morton's neuroma causes metatarsalgia due to the interdigital neuropathy. The small nerve diameter compromises their evaluation in image studies. To overcome this problem we propose a new electrophysiological test. We conducted a prospective case-control study performing a orthodromic electroneurography using subdermal electrodes in controls and patients to assess the validity. Additionally all patients were tested with magnetic resonance. Some patients required surgery and subsequent histological evaluation. The new ENG procedure showed higher sensitivity and specificity. Methodological standardization was easy and the test was well tolerated by the subjects. Our test demonstrated remarkable diagnostic efficiency, and also was able to identify symptomatic patients undetected by magnetic resonance, which underlines the lack of correlation between the size and intensity of the lesion. This new electrophysiological method appears to be a highly sensitivity, well-tolerated, simple and low-cost for Morton's neuroma diagnosis. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  3. Contact sensitivities in palmar plantar pustulosis (acropustulosis).

    PubMed

    Yiannias, J A; Winkelmann, R K; Connolly, S M

    1998-09-01

    Acropustulosis, or chronic palmar plantar pustulosis (PPP), is a phenomenon of recurrent sterile pustules, erythema, and scaling affecting the palms and soles. Its pathogenesis is unclear, and it is difficult to treat. The purpose of this study was to elucidate further the factors involved in causing PPP, thereby enhancing the ability to manage this disease. All cases of PPP seen at Mayo Clinic Scottsdale from 1987 to 1993 were reviewed. 21 patients with PPP were identified, 15 of whom had been patch tested. 9 of the 15 patients (60%) showed positive patch test results. Fragrance was the most common sensitivity, but nickel, formaldehyde, para-phenylenediamine, thiuram, neomycin, mercury, balsam of Peru, and cinnamic aldehyde sensitivities were demonstrated. Less important factors included atopy, fungal and bacterial infections, and irritation. Although the mechanism of this sterile pustulosis response does not depend solely on delayed hypersensitivity mechanisms, we believe that we have demonstrated such a large number of positive patch tests in this chronic pustular dermatosis that patch testing should be considered in the routine work-up of these patients.

  4. A short-term swimming speed alteration test with nauplii of Artemia franciscana.

    PubMed

    Morgana, Silvia; Estévez-Calvar, Noelia; Gambardella, Chiara; Faimali, Marco; Garaventa, Francesca

    2018-01-01

    The presence of toxicant needs to be assessed within short time in order to effectively protect the aquatic environment from serious threat. Based on the observation that at high temperatures aquatic organisms become more vulnerable to stressors than those maintained at room temperature, a new test was developed. The proposed bioassay consisted in the evaluation of the swimming speed alteration (SSA) of nauplii of Artemia franciscana incubated at 39°C (± 1) for 6h, using a Swimming Behavior Recorder system (SBR). A comparative ecotoxicological study between the 6h SSA test and the 24h mortality test was carried out in order to validate the new method in terms of sensitivity by means of EC 50 values. The bioassay was applied to screen different toxicants: K 2 Cr 2 O 7 , Cu(SO 4 ) 2 , NaClO, SDS and Sertraline hydrochloride. The EC 50s calculated for the short-term SSA test and those of the mortality test showed comparable values. For all toxicants, the 6h SSA test was proved to be as sensitive as the 24h mortality test. The method developed in this study is the first temperature-based toxicity test with nauplii of Artemia franciscana and it represents an attractive assay in ecotoxicology because of its convenience in terms of time and costs, feasibility and sensitivity. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Response to novelty as a predictor of cocaine sensitization and conditioning in rats: a correlational analysis.

    PubMed

    Carey, Robert J; DePalma, Gail; Damianopoulos, Ernest

    2003-07-01

    An animal's response to novelty has been suggested to be a predictor of its response to drugs of abuse. The possible relationship between an individual's behavioral response to novelty and its subsequent behavioral response to cocaine has not been subjected to a detailed correlational analysis. To use a repeated cocaine treatment protocol to induce cocaine sensitization and conditioned cocaine locomotor stimulant effects and to assess the relationship of these effects to pre-cocaine locomotor behavior in a novel environment. In two separate experiments, rats were given a 20-min test in a novel open-field environment. Subsequently, the rats were given a series of additional tests in conjunction with either saline or cocaine (10 mg/kg) treatments to induce cocaine sensitization and conditioned effects. The repeated cocaine treatments induced cocaine behavioral sensitization and conditioned effects. Correlational analyses showed that the initial 20-min novel environment test proved to be a strong predictor of an animal's subsequent saline activity level but did not predict the rats' behavioral acute and sensitized response to cocaine. When change in activity was used as the dependent variable, initial activity level was reliably negatively correlated with activity changes on cocaine tests as well as cocaine conditioning tests. The negative correlation between initial activity in a novel environment and the change in activity induced by cocaine indicates that low responders to environmental novelty tend to have the strongest response to cocaine. These results appear consistent with the classic initial value and response rate dependent analyses of stimulant drug effects.

  6. Body piercing and metal allergic contact sensitivity: North American contact dermatitis group data from 2007 to 2010.

    PubMed

    Warshaw, Erin M; Kingsley-Loso, Jaime L; DeKoven, Joel G; Belsito, Donald V; Zug, Kathryn A; Zirwas, Matthew J; Maibach, Howard I; Taylor, James S; Sasseville, Denis; Fowler, Joseph F; Mathias, Charles Gordon Toby; DeLeo, Vincent A; Pratt, Melanie D; Marks, James G; Fransway, Anthony F

    2014-01-01

    This study aimed to examine the association between piercing and patch test sensitivity to metals (nickel, cobalt, and chromium) in North America. A retrospective analysis of 9334 patients tested by the North American Contact Dermatitis Group from 2007 to 2010 was conducted. Nickel sensitivity was statistically associated with at least 1 piercing (risk ratio [RR], 2.52; 95% confidence interval [CI], 2.26-2.81; P < 0.0001) and nickel sensitivity rates increased with the number of piercings (16% for 1 piercing to 32% for ≥ 5 piercings). Prevalence of nickel sensitivity was higher in females (23.2%) than in males (7.1%), but the association with piercing was stronger in males (RR, 2.38; 95% CI, 1.72-3.30; P < 0.0001) than in females (RR, 1.30; CI, 1.13-1.49; P = 0.0002). Crude analysis indicated that cobalt sensitivity was statistically associated with piercing (RR, 1.63; 95% CI, 1.40-1.91; P < 0.0001); however, stratified analysis showed that this relationship was confounded by nickel. After adjusting for nickel sensitivity, the adjusted risk ratio for piercing and cobalt was 0.78 (not significant). Chromium sensitivity was negatively associated with piercing (RR, 0.60; 95% CI, 0.48-0.75; P < 0.0001). Piercing was statistically associated with sensitivity to nickel. This relationship was dose dependent and stronger in males. Cobalt sensitivity was not associated with piercing when adjusted for nickel. Chromium sensitivity was negatively associated with piercing.

  7. Extending the Administration Time of the Letter Fluency Test Increases Sensitivity to Cognitive Status in Aging

    PubMed Central

    Holtzer, R.; Goldin, Y.; Donovick, P.J.

    2010-01-01

    We examined whether extending the administration time of letter fluency from one minute per letter trial (standard administration) to two minutes increased the sensitivity of this test to cognitive status in aging. Participants (mean age = 84.6) were assigned to cognitive impairment (n=20) and control (n=40) groups. Pearson correlations and scatter plot analyses showed that associations between the Dementia Rating Scale scores and letter fluency were higher and less variable when performance on the latter was extended to two minutes. ANOVA showed that the cognitive impairment group generated fewer words in the second minute of the letter fluency task compared to the control group. Finally, discriminant function analyses revealed that extending the letter fluency trials to two minutes increased discrimination between the control and cognitive impairment groups. PMID:19449244

  8. Withdrawal, tolerance, and sensitization to dopamine mediated interoceptive cues in rats trained on a three-lever drug-discrimination task.

    PubMed

    Barrett, Robert J; Caul, William F; Smith, Randy

    2005-05-01

    In the present experiment rats were trained on a three-lever, drug-discrimination task to discriminate the cues associated with 0.30 mg/kg of the indirect dopamine (DA) agonist, amphetamine (AMPH), saline (SAL), and 0.03 mg/kg of the DA, D2 receptor antagonist, haloperidol (HAL). Choice behavior determined from tests on 0.30 and 0.15 mg/kg AMPH, SAL 0.03 and 0.015 mg/kg HAL provided a behavioral baseline presumed to represent changes along a continuum of DA mediated, interoceptive cues. Results from separate groups tested on 0.30 and 0.15 mg/kg AMPH, SAL, 0.03 and 0.015 mg/kg HAL, 24 h post-treatment with an acute 7.5 mg/kg dose of AMPH, showed rapid tolerance and withdrawal to the AMPH cue and sensitization to the HAL cue. The same tests 24 h following treatment with 1.0 mg/kg HAL showed rapid tolerance to the HAL cue, sensitization to the AMPH cue, but not AMPH-like withdrawal cues. Analysis of the results showed that tolerance to the AMPH and HAL cues reflected neuroadaptive baseline shifts and not weaker cue properties. These findings are consistent with predictions from opponent process theory of motivation and provide an animal model to study the motivational consequences that aversive symptoms of AMPH withdrawal such as dysphoria and anhedonia can have on drug-taking behavior.

  9. Pavlovian second-order conditioned analgesia.

    PubMed

    Ross, R T

    1986-01-01

    Three experiments with rat subjects assessed conditioned analgesia in a Pavlovian second-order conditioning procedure by using inhibition of responding to thermal stimulation as an index of pain sensitivity. In Experiment 1, rats receiving second-order conditioning showed longer response latencies during a test of pain sensitivity in the presence of the second-order conditioned stimulus (CS) than rats receiving appropriate control procedures. Experiment 2 found that extinction of the first-order CS had no effect on established second-order conditioned analgesia. Experiment 3 evaluated the effects of post second-order conditioning pairings of morphine and the shock unconditioned stimulus (US). Rats receiving paired morphine-shock presentations showed significantly shorter response latencies during a hot-plate test of pain sensitivity in the presence of the second-order CS than did groups of rats receiving various control procedures; second-order analgesia was attenuated. These data extend the associative account of conditioned analgesia to second-order conditioning situations and are discussed in terms of the mediation of both first- and second-order analgesia by an association between the CS and a representation or expectancy of the US, which may directly activate endogenous pain inhibition systems.

  10. In vitro activity of flomoxef and cefazolin in combination with vancomycin.

    PubMed

    Simon, C; Simon, M

    1991-01-01

    207 clinical isolates from strains of patients from the University Children's Hospital of Kiel were investigated for their in vitro activity with the agar dilution method against flomoxef and cefazolin (alone and partially in combination with vancomycin). Staphylococci were also tested with other cephalosporins (cefoxitin, cefamandole, cefotaxime, cefotetan and latamoxef). Flomoxef and cefazolin always acted more vigorously on staphylococci than the other cephalosporins. Resistance of Staphylococcus aureus strains against flomoxef and cefazolin did not occur but was found in 15 and 5 of 98 Staphylococcus epidermidis strains, respectively. Enterococcus faecalis strains were always resistant against both drugs; Streptococcus faecium strains were only moderately sensitive. Combined testing of flomoxef or cefazolin with vancomycin showed synergism in almost all staphylococcal strains. Synergism was stronger when S. epidermidis strains were only weakly sensitive to or resistant against flomoxef and cefazolin in comparison to highly sensitive strains. Flomoxef (or cefazolin) acted synergistically in combination with vancomycin on E. faecalis and S. faecium with the exception of two strains of E. faecalis which showed an additive effect of both drugs.

  11. Value of the intravenous and oral glucose tolerance tests for detecting subtle impairments in insulin sensitivity and beta-cell function in former gestational diabetes.

    PubMed

    Tura, A; Mari, A; Prikoszovich, T; Pacini, G; Kautzky-Willer, A

    2008-08-01

    Women with former gestational diabetes mellitus (fGDM) often show defects in both insulin sensitivity and beta-cell function but it is not clear which defect plays the major role or which appears first. This might be because fGDM women are often studied as a unique group and not divided according to their glucose tolerance. Different findings might also be the result of using different tests. Our aim was to study insulin sensitivity and beta-cell function with two independent glucose tolerance tests in fGDM women divided according to their glucose tolerance. A total of 108 fGDM women divided into normal glucose tolerance (IGT; N = 82), impaired glucose metabolism (IGM; N = 20) and overt type 2 diabetes (T2DM; N = 6) groups, and 38 healthy control women (CNT) underwent intravenous (IVGTT) and oral glucose tolerance tests (OGTT). Measurements Insulin sensitivity and beta-cell function were assessed by both the IVGTT and the OGTT. Both tests revealed impaired insulin sensitivity in the normotolerant group compared to controls (IVGTT: 4.2 +/- 0.3 vs. 5.4 +/- 0.4 10(-4) min(-1) (microU/ml)(-1); OGTT: 440 +/- 7 vs. 472 +/- 9 ml min(-1) m(-2)). Conversely, no difference was found in beta-cell function from the IVGTT. However, some parameters of beta-cell function by OGTT modelling analysis were found to be impaired: glucose sensitivity (106 +/- 5 vs. 124 +/- 7 pmol min(-1) m(-2) mm(-1), P = 0.0407) and insulin secretion at 5 mm glucose (168 +/- 9 vs. 206 +/- 10 pmol min(-1) m(-2), P = 0.003). Both insulin sensitivity and beta-cell function are impaired in normotolerant fGDM but the subtle defect in beta-cell function is disclosed only by OGTT modelling analysis.

  12. The sensitivity of direct faecal examination, direct faecal flotation, modified centrifugal faecal flotation and centrifugal sedimentation/flotation in the diagnosis of canine spirocercosis.

    PubMed

    Christie, J; Schwan, E V; Bodenstein, L L; Sommerville, J E M; van der Merwe, L L

    2011-06-01

    Several faecal examination techniques have shown variable sensitivity in demonstrating Spirocerca lupi (S. lupi) eggs. The objective of this study was to determine which faecal examination technique, including a novel modified centrifugal flotation technique, was most sensitive to diagnose spirocercosis. Ten coproscopic examinations were performed on faeces collected from 33 dogs confirmed endoscopically to have spirocercosis. The tests included a direct faecal examination, a faecal sedimentation/flotation test, 4 direct faecal flotations and 4 modified faecal centrifugal flotations. These latter 2 flotation tests utilised 4 different faecal flotation solutions: NaNO3 (SG 1.22), MgSO4 (SG 1.29), ZnSO4 (SG 1.30) and sugar (SG 1.27). The sensitivity of the tests ranged between 42% and 67%, with the NaNO3 solution showing the highest sensitivity in both the direct and modified-centrifugal flotations. The modified NaNO3 centrifugal method ranked 1st with the highest mean egg count (45.24 +/- 83), and was superior (i.e. higher egg count) and significantly different (P < 0.05) compared with the routine saturated sugar, ZnSO4 and MgSO4 flotation methods. The routine NaNO3 flotation method was also superior and significantly different (P < 0.05) compared with the routine ZnSO4 and MgSO4 flotation methods. Fifteen per cent (n = 5) of dogs had neoplastic oesophageal nodules and a further 18% (n = 6) had both neoplastic and non-neoplastic nodules. S. lupi eggs were demonstrated in 40% of dogs with neoplastic nodules only and 72.9% of the dogs with non-neoplastic nodules. The mean egg count in the non-neoplastic group (61) was statistically greater (P = 0.02) than that of the neoplastic group (1). The results show that faecal examination using a NaNO3 solution is the most sensitive in the diagnosis of spirocercosis. The modified centrifugal flotation faecal method using this solution has the highest egg count. The study also found that dogs with neoplastic nodules shed significantly fewer eggs than dogs with non-neoplastic nodules.

  13. Diagnostic accuracy of shear wave elastography for prediction of breast malignancy in patients with pathological nipple discharge

    PubMed Central

    Guo, Xiaobo; Liu, Ying; Li, Wanhu

    2016-01-01

    Objectives Pathological nipple discharge (PND) may indicate malignant breast lesions. As the role of shear wave elastography (SWE) in predicting these malignant lesions has not yet been evaluated, we aim to evaluate the diagnostic value of SWE for this condition. Design Prospective diagnostic accuracy study comparing a combination of qualitative and quantitative measurements of SWE (index test) to a ductoscopy and microdochectomy for histological diagnosis (reference test). Setting Fuzhou General Hospital of Nanjing military command. Participants A total of 379 patients with PND were finally included from January, 2011 to March 2014, after we screened 1084 possible candidates. All participants were evaluated through SWE, with qualitative parameters generated by Virtual Touch tissue imaging (VTI) and quantitative parameters generated by Virtual Touch tissue quantification (VTQ). All the patients were consented to receive a ductoscopy and microdochectomy for histological diagnosis, and the results were set as a reference test. Outcome measures Sensitivity and specificity of the combined VTI and VTQ of the SWE for detection of malignancy in patients with PND. Results The 379 participants presented with 404 lesions. The results of pathological examination showed that 326 (80.7%) of the 404 lesions were benign and the other 78 (19.3%) were malignant. An area under the curve of elasticity score, VTQm and VTQc, were 0.872, 0.825 and 0.857, respectively, with the corresponding cut-off point as 2.50, 2.860 m/s and 3.015 m/s, respectively. After a combination of these measurements, the sensitivity, specificity, and positive and negative predictive value (PPV and NPV), were 89.7%, 72.1%, 43.5% and 96.7%, respectively. The sensitivity analysis showed 82% of the sensitivity and 96.8% of the specificity, in which patients with no pathological findings in ductoscopy were excluded. Conclusions Ultrasonographic elastography is sensitive for patients with PND and could be used as a triage test before ductoscopy examination. Studies for further improvement of diagnostic sensitivity are warranted. PMID:26801462

  14. High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO2 Microparticles

    PubMed Central

    Liu, Ming-Qing; Wang, Cong; Kim, Nam-Young

    2017-01-01

    In this study, a high-sensitivity and low-hysteresis porous metal–insulator–metal-type capacitive humidity sensor is investigated using a functional polymer mixed with TiO2 microparticles. The humidity sensor consists of an optimally designed porous top electrode, a functional polymer humidity sensitive layer, a bottom electrode, and a glass substrate. The porous top electrode is designed to increase the contact area between the sensing layer and water vapor, leading to high sensitivity and quick response time. The functional polymer mixed with TiO2 microparticles shows excellent hysteresis under a wide humidity-sensing range with good long-term stability. The results show that as the relative humidity ranges from 10% RH to 90% RH, the proposed humidity sensor achieves a high sensitivity of 0.85 pF/% RH and a fast response time of less than 35 s. Furthermore, the sensor shows an ultra-low hysteresis of 0.95% RH at 60% RH, a good temperature dependence, and a stable capacitance value with a maximum of 0.17% RH drift during 120 h of continuous test. PMID:28157167

  15. The Effects of Allicin, a Reactive Sulfur Species from Garlic, on a Selection of Mammalian Cell Lines

    PubMed Central

    Gruhlke, Martin C. H.; Nicco, Carole; Batteux, Frederic; Slusarenko, Alan J.

    2016-01-01

    Garlic (Allium sativum L.) has been used as a spice and medicinal plant since ancient times. Garlic produces the thiol-reactive defence substance, allicin, upon wounding. The effects of allicin on human lung epithelium carcinoma (A549), mouse fibroblast (3T3), human umbilical vein endothelial cell (HUVEC), human colon carcinoma (HT29) and human breast cancer (MCF7) cell lines were tested. To estimate toxic effects of allicin, we used a standard MTT-test (methylthiazoltetrazolium) for cell viability and 3H-thymidine incorporation for cell proliferation. The glutathione pool was measured using monobromobimane and the formation of reactive species was identified using 2′,7′-dichlorofluoresceine-diacetate. The YO-PRO-1 iodide staining procedure was used to estimate apoptosis. Allicin reduced cell viability and cell proliferation in a concentration dependent manner. In the bimane test, it was observed that cells treated with allicin showed reduced fluorescence, suggesting glutathione oxidation. The cell lines tested differed in sensitivity to allicin in regard to viability, cell proliferation and glutathione oxidation. The 3T3 and MCF-7 cells showed a higher proportion of apoptosis compared to the other cell types. These data show that mammalian cell lines differ in their sensitivity and responses to allicin. PMID:28035949

  16. Genetic variability and resistance of cultivars of cowpea [Vigna unguiculata (L.) Walp] to cowpea weevil (Callosobruchus maculatus Fabr.).

    PubMed

    Vila Nova, M X; Leite, N G A; Houllou, L M; Medeiros, L V; Lira Neto, A C; Hsie, B S; Borges-Paluch, L R; Santos, B S; Araujo, C S F; Rocha, A A; Costa, A F

    2014-03-31

    The cowpea weevil (Callosobruchus maculatus Fabr.) is the most destructive pest of the cowpea bean; it reduces seed quality. To control this pest, resistance testing combined with genetic analysis using molecular markers has been widely applied in research. Among the markers that show reliable results, the inter-simple sequence repeats (ISSRs) (microsatellites) are noteworthy. This study was performed to evaluate the resistance of 27 cultivars of cowpea bean to cowpea weevil. We tested the resistance related to the genetic variability of these cultivars using ISSR markers. To analyze the resistance of cultivars to weevil, a completely randomized test design with 4 replicates and 27 treatments was adopted. Five pairs of the insect were placed in 30 grains per replicate. Analysis of variance showed that the number of eggs and emerged insects were significantly different in the treatments, and the means were compared by statistical tests. The analysis of the large genetic variability in all cultivars resulted in the formation of different groups. The test of resistance showed that the cultivar Inhuma was the most sensitive to both number of eggs and number of emerged adults, while the TE96-290-12-G and MNC99-537-F4 (BRS Tumucumaque) cultivars were the least sensitive to the number of eggs and the number of emerged insects, respectively.

  17. Full-Scale Hollow Fiber Spacesuit Water Membrane Evaporator Prototype Development and Testing for Advanced Spacesuits

    NASA Technical Reports Server (NTRS)

    Bue, Grant; Trevino, Luis; Tsioulos, Gus; Mitchell, Keith; Dillon, Paul; Weaver, Gregg

    2009-01-01

    The spacesuit water membrane evaporator (SWME) is being developed to perform the thermal control function for advanced spacesuits to take advantage of recent advances in micropore membrane technology in providing a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. Principles of a sheet membrane SWME design were demonstrated using a prototypic test article that was tested in a vacuum chamber at JSC in July 1999. The Membrana Celgard X50-215 microporous hollow fiber (HoFi) membrane was selected after recent contamination tests as the superior candidate among commercial alternatives for HoFi SWME prototype development. Although a number of design variants were considered, one that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was deemed best for further development. An analysis of test data showed that eight layer stacks of the HoFi sheets that had good exposure on each side of the stack would evaporate water with high efficiency. A design that has 15,000 tubes, with 18 cm of exposed tubes between headers has been built and tested that meets the size, weight, and performance requirements of the SWME. This full-scale prototype consists of 30 stacks, each of which are formed into a chevron shape and separated by spacers and organized into three sectors of ten nested stacks. Testing has been performed to show contamination resistance to the constituents expected to be found in potable water produced by the distillation processes. Other tests showed the sensitivity to surfactants.

  18. A method for identifying color vision deficiency malingering.

    PubMed

    Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo

    2017-03-01

    To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.

  19. Sensitive detection of influenza viruses with Europium nanoparticles on an epoxy silica sol-gel functionalized polycarbonate-polydimethylsiloxane hybrid microchip.

    PubMed

    Liu, Jikun; Zhao, Jiangqin; Petrochenko, Peter; Zheng, Jiwen; Hewlett, Indira

    2016-12-15

    In an effort to develop new tools for diagnosing influenza in resource-limited settings, we fabricated a polycarbonate (PC)-polydimethylsiloxane (PDMS) hybrid microchip using a simple epoxy silica sol-gel coating/bonding method and employed it in sensitive detection of influenza virus with Europium nanoparticles (EuNPs). The incorporation of sol-gel material in device fabrication provided functionalized channel surfaces ready for covalent immobilization of primary antibodies and a strong bonding between PDMS substrates and PC supports without increasing background fluorescence. In microchip EuNP immunoassay (µENIA) of inactivated influenza viruses, replacing native PDMS microchips with hybrid microchips allowed the achievement of a 6-fold increase in signal-to-background ratio, a 12-fold and a 6-fold decreases in limit-of-detection (LOD) in influenza A and B tests respectively. Using influenza A samples with known titers, the LOD of influenza µENIA on hybrid microchips was determined to be ~10(4) TCID50 titer/mL and 10(3)-10(4) EID50 titer/mL. A comparison test indicated that the sensitivity of influenza µENIA enhanced using the hybrid microchips even surpassed that of a commercial laboratory influenza ELISA test. In addition to the sensitivity improvement, assay variation was clearly reduced when hybrid microchips instead of native PDMS microchips were used in the µENIA tests. Finally, infectious reference viruses and nasopharyngeal swab patient specimens were successfully tested using μENIA on hybrid microchip platforms, demonstrating the potential of this unique microchip nanoparticle assay in clinical diagnosis of influenza. Meanwhile, the tests showed the necessity of using nucleic acid confirmatory tests to clarify ambiguous test results obtained from prototype or developed point-of-care testing devices for influenza diagnosis. Published by Elsevier B.V.

  20. Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.

    PubMed

    Hot, Aliya; Dul, Mitchell W; Swanson, William H

    2008-07-01

    To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4 degrees circular region. Threshold was estimated by a staircase method: Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24-2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test-retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area. Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001). The implementation of CSP was successful in reducing test-retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area.

  1. Diagnostic performance of serological tests for swine brucellosis in the presence of false positive serological reactions.

    PubMed

    Dieste-Pérez, L; Blasco, J M; de Miguel, M J; Moriyón, I; Muñoz, P M

    2015-04-01

    Swine brucellosis caused by Brucella suis biovar 2 is an emerging disease in Europe. Currently used diagnostic tests for swine brucellosis detect antibodies to the O-polysaccharide (O-PS) of Brucella smooth lipopolysaccharide (S-LPS) but their specificity is compromised by false-positive serological reactions (FPSRs) when bacteria carrying cross-reacting O-PS infect pigs. FPSRs occur throughout Europe, and the only tool available for a specific B. suis diagnosis is the intradermal test with Brucella protein extracts free of O-PS or S-LPS. Using sera of 162 sows naturally infected by B. suis biovar 2, 406 brucellosis-free sows, and 218 pigs of brucellosis-free farms affected by FPSR, we assessed the diagnostic performance of an indirect ELISA with rough LPS (thus devoid of O-PS) and of gel immunodiffusion, counterimmunoelectrophoresis, latex agglutination and indirect ELISA with O-PS free proteins in comparison with several S-LPS tests (Rose Bengal, complement fixation, gel immunodiffusion and indirect ELISA). When adjusted to 100% specificity, the sensitivity of the rough LPS ELISA was very low (30%), and adoption of other cut-offs resulted in poor specificity/sensitivity ratios. Although their specificity was 100%, the sensitivity of protein tests (ELISA, latex agglutination, counterimmunoelectrophoresis, and gel immunodiffusion) was only moderate (45, 58, 61 and 63%, respectively). Among S-LPS tests, gel immunodiffusion was the only test showing acceptable sensitivity/specificity (68 and 100%, respectively). Despite these shortcomings, and when the purpose is to screen out FPSR at herd level, gel immunodiffusion tests may offer a technically simple and practical alternative to intradermal testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. High Sensitivity, One-Sided X-Ray Inspection System.

    DTIC Science & Technology

    1985-07-01

    8217. X-Ray Imaging Quantitative NDT One-Sided Inspection Backs cat ter De laminat ions .. Nondestructive Testing (NDT) Rocket Motor Case NDT ’j 20...epoxy composites and other low atomic number materials have been detected. Wall thick nesses up to 7 cm thick have been interrogated. The results show...fiber composite rocket motor pressure vessels, the anticipated backscatter x-ray instrument will offer high sensitivity (contact delaminations have

  3. New directions in diagnostic evaluation of insect allergy.

    PubMed

    Golden, David B K

    2014-08-01

    Diagnosis of insect sting allergy and prediction of risk of sting anaphylaxis are often difficult because tests for venom-specific IgE antibodies have a limited positive predictive value and do not reliably predict the severity of sting reactions. Component-resolved diagnosis using recombinant venom allergens has shown promise in improving the specificity of diagnostic testing for insect sting allergy. Basophil activation tests have been explored as more sensitive assays for identification of patients with insect allergy and for prediction of clinical outcomes. Measurement of mast cell mediators reflects the underlying risk for more severe reactions and limited clinical response to treatment. Measurement of IgE to recombinant venom allergens can distinguish cross-sensitization from dual sensitization to honeybee and vespid venoms, thus helping to limit venom immunotherapy to a single venom instead of multiple venoms in many patients. Basophil activation tests can detect venom allergy in patients who show no detectable venom-specific IgE in standard diagnostic tests and can predict increased risk of systemic reactions to venom immunotherapy, and to stings during and after stopping venom immunotherapy. The risk of severe or fatal anaphylaxis to stings can also be predicted by measurement of baseline serum tryptase or other mast cell mediators.

  4. Residual fMRI sensitivity for identity changes in acquired prosopagnosia.

    PubMed

    Fox, Christopher J; Iaria, Giuseppe; Duchaine, Bradley C; Barton, Jason J S

    2013-01-01

    While a network of cortical regions contribute to face processing, the lesions in acquired prosopagnosia are highly variable, and likely result in different combinations of spared and affected regions of this network. To assess the residual functional sensitivities of spared regions in prosopagnosia, we designed a rapid event-related functional magnetic resonance imaging (fMRI) experiment that included pairs of faces with same or different identities and same or different expressions. By measuring the release from adaptation to these facial changes we determined the residual sensitivity of face-selective regions-of-interest. We tested three patients with acquired prosopagnosia, and all three of these patients demonstrated residual sensitivity for facial identity changes in surviving fusiform and occipital face areas of either the right or left hemisphere, but not in the right posterior superior temporal sulcus. The patients also showed some residual capabilities for facial discrimination with normal performance on the Benton Facial Recognition Test, but impaired performance on more complex tasks of facial discrimination. We conclude that fMRI can demonstrate residual processing of facial identity in acquired prosopagnosia, that this adaptation can occur in the same structures that show similar processing in healthy subjects, and further, that this adaptation may be related to behavioral indices of face perception.

  5. Residual fMRI sensitivity for identity changes in acquired prosopagnosia

    PubMed Central

    Fox, Christopher J.; Iaria, Giuseppe; Duchaine, Bradley C.; Barton, Jason J. S.

    2013-01-01

    While a network of cortical regions contribute to face processing, the lesions in acquired prosopagnosia are highly variable, and likely result in different combinations of spared and affected regions of this network. To assess the residual functional sensitivities of spared regions in prosopagnosia, we designed a rapid event-related functional magnetic resonance imaging (fMRI) experiment that included pairs of faces with same or different identities and same or different expressions. By measuring the release from adaptation to these facial changes we determined the residual sensitivity of face-selective regions-of-interest. We tested three patients with acquired prosopagnosia, and all three of these patients demonstrated residual sensitivity for facial identity changes in surviving fusiform and occipital face areas of either the right or left hemisphere, but not in the right posterior superior temporal sulcus. The patients also showed some residual capabilities for facial discrimination with normal performance on the Benton Facial Recognition Test, but impaired performance on more complex tasks of facial discrimination. We conclude that fMRI can demonstrate residual processing of facial identity in acquired prosopagnosia, that this adaptation can occur in the same structures that show similar processing in healthy subjects, and further, that this adaptation may be related to behavioral indices of face perception. PMID:24151479

  6. Chemical crosslinking of acrylic acid to form biocompatible pH sensitive hydrogel reinforced with cellulose nanocrystals (CNC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Lim Sze; Ahmad, Ishak; Lazim, Mohd Azwani Shah Mat

    2014-09-03

    The purpose of this study is to produce a novel pH and temperature sensitive hydrogel, composed of poly(acrylic acid) (PAA) and cellulose nanocrystal (CNC). CNC was extracted from kenaf fiber through a series of alkali and bleaching treatments followed by acid hydrolysis. The PAA was then subjected to chemical cross-linking using the cross-linking agent (N,N-methylenebisacrylamide) with CNC entrapped in PAA matrix. The mixture was casted onto petri dish to obtain disc shape hydrogel. The effects of reaction conditions such as the ratio of PAA and CNC on the swelling behavior of the hydrogel obtained towards pH and temperature were studied.more » The obtained hydrogel was further subjected to different tests such swelling test for swelling behaviour at different pH and temperature along with scanning electron microscopy (SEM) for morphology analysis. The hydrogel obtained showed excellent pH sensitivity and obtained maximum swelling at pH 7. Besides that, hydrogel obtained showed significant increase in swelling ratio when temperature of swelling medium was increased from 25°C to 37°C. SEM micrograph showed that the pore size of the hydrogel decreases with increase of CNC content proving that the hydrogel structure became more rigid with addition of CNC. The PAA/CNC hydrogel with such excellent sensitivity towards pH and temperature can be developed further as drug carrier.« less

  7. The relationship between CD86/CD54 expression and THP-1 cell viability in an in vitro skin sensitization test--human cell line activation test (h-CLAT).

    PubMed

    Sakaguchi, Hitoshi; Ashikaga, Takao; Miyazawa, Masaaki; Kosaka, Nanae; Ito, Yuichi; Yoneyama, Katsurako; Sono, Sakiko; Itagaki, Hiroshi; Toyoda, Hidekazu; Suzuki, Hiroyuki

    2009-04-01

    Recent regulations for cosmetics in Europe prohibit animal testing for evaluating the sensitization potential of chemicals to improve animal welfare. Yet, there is not an acceptable Organization for Economic Co-operation and Development non-animal skin sensitization test method. Several in vitro skin sensitization methods that focus on the activation of Langerhans cells, including human cell lines, are being evaluated as possible alternatives. In our previous study, we optimized our human cell line activation test (h-CLAT) using THP-1 cells (monocytic leukemia cell line) and conducted an inter-laboratory study. We found that measuring CD86/CD54 expression may be useful for predicting skin sensitization. The aim of this study was to confirm the relationship between CD86/CD54 expression and THP-1 cell viability in the h-CLAT. In this study, 21 allergens (e.g., dinitrochlorobenzene, p-phenylenediamine, Ni) and 8 non-allergens (e.g., SLS, lactic acid) were evaluated. For each chemical, more than 10 concentrations that gave a predicted cell viability range of 20-95% were used. The data showed that expression patterns of CD86/CD54 differed depending on chemical. For most allergens, cytotoxicity (65-90% cell viability) was needed for enhancement of CD86/CD54 expression. The criteria of "CD86 > or = 150 or CD54 > or = 200" resulted in an accuracy of 93%, which confirms appropriate cut-off criteria for h-CLAT. Furthermore, a good correlation was observed between EC3 of local lymph node assay and EC150(CD86) or EC200(CD54) of h-CLAT (12 or 16 chemicals, respectively), which would provide a useful estimate of allergic potency. These findings suggest that h-CLAT would be a good robust in vitro skin sensitization test.

  8. Detection of Echinococcus multilocularis by MC-PCR: evaluation of diagnostic sensitivity and specificity without gold standard.

    PubMed

    Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter

    2016-01-01

    A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).

  9. Olfactory Sensitivity for Six Predator Odorants in CD-1 Mice, Human Subjects, and Spider Monkeys

    PubMed Central

    Sarrafchi, Amir; Odhammer, Anna M. E.; Hernandez Salazar, Laura Teresa; Laska, Matthias

    2013-01-01

    Using a conditioning paradigm, we assessed the olfactory sensitivity of six CD-1 mice (Mus musculus) for six sulfur-containing odorants known to be components of the odors of natural predators of the mouse. With all six odorants, the mice discriminated concentrations <0.1 ppm (parts per million) from the solvent, and with five of the six odorants the best-scoring animals were even able to detect concentrations <1 ppt (parts per trillion). Four female spider monkeys (Ateles geoffroyi) and twelve human subjects (Homo sapiens) tested in parallel were found to detect the same six odorants at concentrations <0.01 ppm, and with four of the six odorants the best-scoring animals and subjects even detected concentrations <10 ppt. With all three species, the threshold values obtained here are generally lower than (or in the lower range of) those reported for other chemical classes tested previously, suggesting that sulfur-containing odorants may play a special role in olfaction. Across-species comparisons showed that the mice were significantly more sensitive than the human subjects and the spider monkeys with four of the six predator odorants. However, the human subjects were significantly more sensitive than the mice with the remaining two odorants. Human subjects and spider monkeys significantly differed in their sensitivity with only two of the six odorants. These comparisons lend further support to the notion that the number of functional olfactory receptor genes or the relative or absolute size of the olfactory bulbs are poor predictors of a species’ olfactory sensitivity. Analysis of odor structure–activity relationships showed that in both mice and human subjects the type of alkyl rest attached to a thietane and the type of oxygen moiety attached to a thiol significantly affected olfactory sensitivity. PMID:24278296

  10. Improvement of a PCR test to diagnose infection by Mansonella ozzardi.

    PubMed

    Vera, Luana Janaína Souza; Basano, Sergio de Almeida; Camargo, Juliana de Souza Almeida Aranha; França, Andonai Krauze de; Ferreira, Ricardo de Godoi Mattos; Casseb, Almeida Andrade; Medeiros, Jansen Fernandes; Fontes, Gilberto; Camargo, Luís Marcelo Aranha

    2011-01-01

    Mansonelliasis is caused by Mansonella ozzardi. It is widespread in the Amazon region, with a high prevalence. The common exam of thick blood smears stained with Giemsa shows low efficacy levels and has been an obstacle to diagnosing individuals with low blood parasitemia. In order to increase diagnosis efficacy, the PCR technique was improved. PCR demonstrated the best performance, with sensitivity and negative predictive values (NPV) of 100%, followed by blood filtration through membrane filters, which showed a sensitivity of 88.9% and a NPV of 84.6%, when compared to thick blood smears.

  11. [Comparison of eight screening tests for ant-HCV antibody].

    PubMed

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  12. Diagnosis of Caprine Arthritis Encephalitis Virus infection in dairy goats by ELISA, PCR and Viral Culture.

    PubMed

    Panneum, S; Rukkwamsuk, T

    2017-03-01

    For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.

  13. Comparison of TB-LAMP, GeneXpert MTB/RIF and culture for diagnosis of pulmonary tuberculosis in The Gambia.

    PubMed

    Bojang, Adama L; Mendy, Francis S; Tientcheu, Leopold D; Otu, Jacob; Antonio, Martin; Kampmann, Beate; Agbla, Schadrac; Sutherland, Jayne S

    2016-03-01

    Diagnosis of tuberculosis (TB) remains difficult, particularly in resource-limited settings. The development of nucleic acid-based tests for detection of Mycobacterium tuberculosis complex (MTBC) has significantly increased sensitivity compared to conventional smear microscopy and provides results within a matter of hours compared to weeks for the current gold-standard, liquid culture. In this study we performed side-by-side comparison of mycobacterial detection assays on sputum samples from 285 subjects presenting with symptoms suggestive of TB in The Gambia and a cross-sectional cohort of 156 confirmed TB patients with a median of 2 months of treatment. A novel assay, Loop-Mediated Amplification test for TB (TB-LAMP), was compared to smear microscopy, MGIT culture and GeneXpert MTB/RIF for all samples. When culture was used as the reference standard, we found an overall sensitivity for TB-LAMP of 99% (95% CI: 94.5-99.8) and specificity of 94% (95% CI: 89.3-96.7). When latent class analysis was performed, TB-LAMP had 98.6% (95% CI: 95.9-100) sensitivity and 99% (95% CI: 98.2-100) specificity compared to 91.1% (95% CI: 86.1-96) sensitivity and 100% (95% CI: 98.2-100) specificity for MGIT culture. GeneXpert had the highest sensitivity 99.1% (95% CI: 97.1-100) but the lowest specificity 96% (95% CI: 92.6-98.3). Both TB-LAMP and GeneXpert showed high sensitivity and specificity regardless of age or strain of infection. Our findings show the diagnostic utility of both GeneXpert and TB-LAMP in The Gambia. Whilst TB-LAMP requires less infrastructure, it is unable to detect drug-resistant patterns and therefore would be most suitable as a screening test for new TB cases in peripheral health clinics. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  14. Pandemic preparedness in Hawaii: a multicenter verification of real-time RT-PCR for the direct detection of influenza virus types A and B.

    PubMed

    Whelen, A Christian; Bankowski, Matthew J; Furuya, Glenn; Honda, Stacey; Ueki, Robert; Chan, Amelia; Higa, Karen; Kumashiro, Diane; Moore, Nathaniel; Lee, Roland; Koyamatsu, Terrie; Effler, Paul V

    2010-01-01

    We integrated multicenter, real-time (RTi) reverse transcription polymerase chain reaction (RT-PCR) screening into a statewide laboratory algorithm for influenza surveillance and response. Each of three sites developed its own testing strategy and was challenged with one randomized and blinded panel of 50 specimens previously tested for respiratory viruses. Following testing, each participating laboratory reported its results to the Hawaii State Department of Health, State Laboratories Division for evaluation and possible discrepant analysis. Two of three laboratories reported a 100% sensitivity and specificity, resulting in a 100% positive predictive value and a 100% negative predictive value (NPV) for influenza type A. The third laboratory showed a 71% sensitivity for influenza type A (83% NPV) with 100% specificity. All three laboratories were 100% sensitive and specific for the detection of influenza type B. Discrepant analysis indicated that the lack of sensitivity experienced by the third laboratory may have been due to the analyte-specific reagent probe used by that laboratory. Use of a newer version of the product with a secondary panel of 20 specimens resulted in a sensitivity and specificity of 100%. All three laboratories successfully verified their ability to conduct clinical testing for influenza using diverse nucleic acid extraction and RTi RT-PCR platforms. Successful completion of the verification by all collaborating laboratories paved the way for the integration of those facilities into a statewide laboratory algorithm for influenza surveillance and response.

  15. Performance of Polymerase Chain Reaction Analysis of the Amniotic Fluid of Pregnant Women for Diagnosis of Congenital Toxoplasmosis: A Systematic Review and Meta-Analysis.

    PubMed

    de Oliveira Azevedo, Christianne Terra; do Brasil, Pedro Emmanuel A A; Guida, Letícia; Lopes Moreira, Maria Elizabeth

    2016-01-01

    Congenital infection caused by Toxoplasma gondii can cause serious damage that can be diagnosed in utero or at birth, although most infants are asymptomatic at birth. Prenatal diagnosis of congenital toxoplasmosis considerably improves the prognosis and outcome for infected infants. For this reason, an assay for the quick, sensitive, and safe diagnosis of fetal toxoplasmosis is desirable. To systematically review the performance of polymerase chain reaction (PCR) analysis of the amniotic fluid of pregnant women with recent serological toxoplasmosis diagnoses for the diagnosis of fetal toxoplasmosis. A systematic literature review was conducted via a search of electronic databases; the literature included primary studies of the diagnostic accuracy of PCR analysis of amniotic fluid from pregnant women who seroconverted during pregnancy. The PCR test was compared to a gold standard for diagnosis. A total of 1.269 summaries were obtained from the electronic database and reviewed, and 20 studies, comprising 4.171 samples, met the established inclusion criteria and were included in the review. The following results were obtained: studies about PCR assays for fetal toxoplasmosis are generally susceptible to bias; reports of the tests' use lack critical information; the protocols varied among studies; the heterogeneity among studies was concentrated in the tests' sensitivity; there was evidence that the sensitivity of the tests increases with time, as represented by the trimester; and there was more heterogeneity among studies in which there was more time between maternal diagnosis and fetal testing. The sensitivity of the method, if performed up to five weeks after maternal diagnosis, was 87% and specificity was 99%. The global sensitivity heterogeneity of the PCR test in this review was 66.5% (I(2)). The tests show low evidence of heterogeneity with a sensitivity of 87% and specificity of 99% when performed up to five weeks after maternal diagnosis. The test has a known performance and could be recommended for use up to five weeks after maternal diagnosis, when there is suspicion of fetal toxoplasmosis.

  16. Comparison of the diagnostic ability of Moorfield’s regression analysis and glaucoma probability score using Heidelberg retinal tomograph III in eyes with primary open angle glaucoma

    PubMed Central

    Jindal, Shveta; Dada, Tanuj; Sreenivas, V; Gupta, Viney; Sihota, Ramanjit; Panda, Anita

    2010-01-01

    Purpose: To compare the diagnostic performance of the Heidelberg retinal tomograph (HRT) glaucoma probability score (GPS) with that of Moorfield’s regression analysis (MRA). Materials and Methods: The study included 50 eyes of normal subjects and 50 eyes of subjects with early-to-moderate primary open angle glaucoma. Images were obtained by using HRT version 3.0. Results: The agreement coefficient (weighted k) for the overall MRA and GPS classification was 0.216 (95% CI: 0.119 – 0.315). The sensitivity and specificity were evaluated using the most specific (borderline results included as test negatives) and least specific criteria (borderline results included as test positives). The MRA sensitivity and specificity were 30.61 and 98% (most specific) and 57.14 and 98% (least specific). The GPS sensitivity and specificity were 81.63 and 73.47% (most specific) and 95.92 and 34.69% (least specific). The MRA gave a higher positive likelihood ratio (28.57 vs. 3.08) and the GPS gave a higher negative likelihood ratio (0.25 vs. 0.44).The sensitivity increased with increasing disc size for both MRA and GPS. Conclusions: There was a poor agreement between the overall MRA and GPS classifications. GPS tended to have higher sensitivities, lower specificities, and lower likelihood ratios than the MRA. The disc size should be taken into consideration when interpreting the results of HRT, as both the GPS and MRA showed decreased sensitivity for smaller discs and the GPS showed decreased specificity for larger discs. PMID:20952832

  17. Heavy Ion and Proton-Induced Single Event Upset Characteristics of a 3D NAND Flash Memory

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Wilcox, Edward; Ladbury, Raymond; Seidleck, Christina; Kim, Hak; Phan, Anthony; Label, Kenneth

    2017-01-01

    We evaluated the effects of heavy ion and proton irradiation for a 3D NAND flash. The 3D NAND showed similar single-event upset (SEU) sensitivity to a planar NAND of identical density in the multiple-cell level (MLC) storage mode. The 3D NAND showed significantly reduced SEU susceptibility in single-level-cell (SLC) storage mode. Additionally, the 3D NAND showed less multiple-bit upset susceptibility than the planar NAND, with fewer number of upset bits per byte and smaller cross sections overall. However, the 3D architecture exhibited angular sensitivities for both base and face angles, reflecting the anisotropic nature of the SEU vulnerability in space. Furthermore, the SEU cross section decreased with increasing fluence for both the 3D NAND and the Micron 16 nm planar NAND, which suggests that typical heavy ion test fluences will underestimate the upset rate during a space mission. These unique characteristics introduce complexity to traditional ground irradiation test procedures.

  18. Application of the pressure sensitive paint technique to steady and unsteady flow

    NASA Technical Reports Server (NTRS)

    Shimbo, Y.; Mehta, R.; Cantwell, B.

    1996-01-01

    Pressure sensitive paint is a newly-developed optical measurement technique with which one can get a continuous pressure distribution in much shorter time and lower cost than a conventional pressure tap measurement. However, most of the current pressure sensitive paint applications are restricted to steady pressure measurement at high speeds because of the small signal-to-noise ratio at low speed and a slow response to pressure changes. In the present study, three phases of work have been completed to extend the application of the pressure sensitive paint technique to low-speed testing and to investigate the applicability of the paint technique to unsteady flow. First the measurement system using a commercially available PtOEP/GP-197 pressure sensitive paint was established and applied to impinging jet measurements. An in-situ calibration using only five pressure tap data points was applied and the results showed good repeatability and good agreement with conventional pressure tap measurements on the whole painted area. The overall measurement accuracy in these experiments was found to be within 0.1 psi. The pressure sensitive paint technique was then applied to low-speed wind tunnel tests using a 60 deg delta wing model with leading edge blowing slots. The technical problems encountered in low-speed testing were resolved by using a high grade CCD camera and applying corrections to improve the measurement accuracy. Even at 35 m/s, the paint data not only agreed well with conventional pressure tap measurements but also clearly showed the suction region generated by the leading edge vortices. The vortex breakdown was also detected at alpha=30 deg. It was found that a pressure difference of 0.2 psi was required for a quantitative pressure measurement in this experiment and that temperature control or a parallel temperature measurement is necessary if thermal uniformity does not hold on the model. Finally, the pressure sensitive paint was applied to a periodically changing pressure field with a 12.8s time period. A simple first-order pole model was applied to deal with the phase lag of the paint. The unsteady pressure estimated from the time-changing pressure sensitive paint data agreed well with the pressure transducer data in regions of higher pressure and showed the possibility of extending the technique to unsteady pressure measurements. However, the model still needs further refinement based on the physics of the oxygen diffusion into the paint layer and the oxygen quenching on the paint luminescence.

  19. Usefulness of Two Aspergillus PCR Assays and Aspergillus Galactomannan and β-d-Glucan Testing of Bronchoalveolar Lavage Fluid for Diagnosis of Chronic Pulmonary Aspergillosis

    PubMed Central

    Urabe, Naohisa; Sano, Go; Suzuki, Junko; Hebisawa, Akira; Nakamura, Yasuhiko; Koyama, Kazuya; Ishii, Yoshikazu; Tateda, Kazuhiro; Homma, Sakae

    2017-01-01

    ABSTRACT We evaluated the usefulness of an Aspergillus galactomannan (GM) test, a β-d-glucan (βDG) test, and two different Aspergillus PCR assays of bronchoalveolar lavage fluid (BALF) samples for the diagnosis of chronic pulmonary aspergillosis (CPA). BALF samples from 30 patients with and 120 patients without CPA were collected. We calculated the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each test individually and in combination with other tests. The optical density index values, as determined by receiver operating characteristic analysis, for the diagnosis of CPA were 0.5 and 100 for GM and βDG testing of BALF, respectively. The sensitivity and specificity of the GM test, βDG test, and PCR assays 1 and 2 were 77.8% and 90.0%, 77.8% and 72.5%, 86.7% and 84.2%, and 66.7% and 94.2%, respectively. A comparison of the PCR assays showed that PCR assay 1 had a better sensitivity, a better negative predictive value, and a better negative likelihood ratio and PCR assay 2 had a better specificity, a better positive predictive value, and a better positive likelihood ratio. The combination of the GM and βDG tests had the highest diagnostic odds ratio. The combination of the GM and βDG tests on BALF was more useful than any single test for diagnosing CPA. PMID:28330887

  20. Comparison of commercial ELISA tests for the detection of Toxoplasma antibodies in the meat juice of naturally infected pigs.

    PubMed

    Felin, Elina; Näreaho, Anu; Fredriksson-Ahomaa, Maria

    2017-04-30

    Toxoplasmosis is a globally distributed protozoal zoonosis. Pigs are considered an important reservoir of Toxoplasma gondii and pork a major infection source of human toxoplasmosis. ELISA methods are commonly used diagnostic tools for detecting Toxoplasma infections. They are also used for slaughterhouse-based serological monitoring of toxoplasmosis in pigs to identify positive farms. The methods used are non-standardised with varying sensitivity and specificity. In our study, four commercial ELISA tests for the detection of Toxoplasma antibodies in the meat juice of slaughter pigs were compared with a modified agglutination test (MAT) as a reference. The cut-off values of the ELISA tests provided by the manufacturer varied between 0.20 and 0.50, and clearly influenced prevalence. The sensitivity of tests I, II and III varied between 96.4 and 78.6. Sensitivity was unacceptably low (3.6) for test IV (cut-off=0.30). Tests I, II and III had the highest accuracy and the best agreement with the reference test when a cut-off of 0.30 was used. Test II and III showed very good agreement (K=0.92 and 0.84, respectively) with the MAT. A very strong correlation (Pearson correlation >0.89) was observed between the S/P values of tests I, II and III. Our results demonstrate that the test and cut-off value used influence the results of the apparent seroprevalence studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Evaluation of the toxicity of two soils from Jales Mine (Portugal) using aquatic bioassays.

    PubMed

    Loureiro, Susana; Ferreira, Abel L G; Soares, Amadeu M V M; Nogueira, António J A

    2005-10-01

    Soil contamination can be one path for streams and groundwater contamination. As a complement of chemical analysis and total contaminants determination, bioassays can provide information on the bioavailable fraction of chemical compounds, focusing on the retention and habitat function of soils. In this study the evaluation of the toxicity of two soils from the abandoned Jales Mine (Portugal) regarded both functions. The buffer capacity of soils was tested with bioassays carried out using the cladoceran Daphnia magna and the marine bacteria Vibrio fischeri. The habitat function of soils was evaluated with the reproduction bioassay with the collembolan Folsomia candida. The Microtox solid-phase test was performed with V. fischeri using soil as test medium, and soil elutriates were extracted to perform the Microtox basic test, and an immobilization and reproduction bioassay with D. magna. The marine bacteria showed high sensitivity to the soil with low heavy metal content (JNC soil) and to JNC soil elutriates, while the soil with highest heavy metal content (JC soil) or soil elutriates exposure did not cause any toxic effect. In the bioassays with D. magna, organisms showed sensitivity to JNC and also to JC soil elutriates. Both mobilization and reproduction features were inhibited. The bioassay with F. candida did not reflect any influence of the contaminants on their reproduction. Although JNC soil presented lower heavy metal contents, elutriates showed different patterns of contamination when compared to JC soil and elutriates, which indicates different retention and buffer capacities between soils. Results obtained in this study underlined the sensitivity and importance of soil elutriate bioassays with aquatic organisms in the evaluation strategy in soil ERA processes.

  2. Oxidative status in different settings and with different methodological approaches compared by Receiver Operating Characteristic curve analysis.

    PubMed

    Cighetti, Giuliana; Bamonti, Fabrizia; Aman, Caroline S; Gregori, Dario; De Giuseppe, Rachele; Novembrino, Cristina; de Liso, Federica; Maiavacca, Rita; Paroni, Rita

    2015-01-01

    To test the performance of different analytical approaches in highlighting the occurrence of deregulated redox status in various physio-pathological situations. 35 light and 61 heavy smokers, 19 chronic renal failure, 59 kidney transplanted patients, and 87 healthy controls were retrospectively considered for the study. Serum oxidative stress and antioxidant status, assessed by spectrophotometric Reactive Oxygen Metabolites (d-ROMs) and Total Antioxidant Capacity (TAC) tests, respectively, were compared with plasma free (F-MDA) and total (T-MDA) malondialdehyde, both quantified by isotope-dilution-gas chromatography-mass spectrometry (ID-GC-MS). Sensitivity, specificity and cut-off points of T-MDA, F-MDA, d-ROMs and TAC were evaluated by both Receiver Operating Characteristic (ROC) analyses and area under the ROC curve (AUC). Only T-MDA assay showed a clear absence of oxidative stress in controls and significant increase in all patients (AUC 1.00, sensitivity and specificity 100%). Accuracy was good for d-ROMs (AUC 0.87, sensitivity 72.8%, specificity 100%) and F-MDA (AUC 0.82, sensitivity 74.7%, specificity 83.9%), but not high enough for TAC to show in patients impaired antioxidant defense (AUC 0.66, sensitivity 52.0%, specificity 92.9%). This study reveals T-MDA as the best marker to detect oxidative stress, shows the ability of d-ROMs to identify modified oxidative status particularly in the presence of high damages, and evidences the poor TAC performance. d-ROMs and TAC assays could be useful for routine purposes; however, for an accurate clinical data evaluation, their comparison versus a "gold standard method" is required. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Clinical usefulness of the clock drawing test applying rasch analysis in predicting of cognitive impairment.

    PubMed

    Yoo, Doo Han; Lee, Jae Shin

    2016-07-01

    [Purpose] This study examined the clinical usefulness of the clock drawing test applying Rasch analysis for predicting the level of cognitive impairment. [Subjects and Methods] A total of 187 stroke patients with cognitive impairment were enrolled in this study. The 187 patients were evaluated by the clock drawing test developed through Rasch analysis along with the mini-mental state examination of cognitive evaluation tool. An analysis of the variance was performed to examine the significance of the mini-mental state examination and the clock drawing test according to the general characteristics of the subjects. Receiver operating characteristic analysis was performed to determine the cutoff point for cognitive impairment and to calculate the sensitivity and specificity values. [Results] The results of comparison of the clock drawing test with the mini-mental state showed significant differences in according to gender, age, education, and affected side. A total CDT of 10.5, which was selected as the cutoff point to identify cognitive impairement, showed a sensitivity, specificity, Youden index, positive predictive, and negative predicive values of 86.4%, 91.5%, 0.8, 95%, and 88.2%. [Conclusion] The clock drawing test is believed to be useful in assessments and interventions based on its excellent ability to identify cognitive disorders.

  4. Extending the Constant Power Speed Range of the Brushless DC Motor through Dual Mode Inverter Control -- Part II: Laboratory Proof-of-Principle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawler, J.S.

    2001-10-29

    Previous theoretical work has shown that when all loss mechanisms are neglected the constant power speed range (CPSR) of a brushless dc motor (BDCM) is infinite when the motor is driven by the dual-mode inverter control (DMIC) [1,2]. In a physical drive, losses, particularly speed-sensitive losses, will limit the CPSR to a finite value. In this paper we report the results of laboratory testing of a low-inductance, 7.5-hp BDCM driven by the DMIC. The speed rating of the test motor rotor limited the upper speed of the testing, and the results show that the CPSR of the test machine ismore » greater than 6:1 when driven by the DMIC. Current wave shape, peak, and rms values remained controlled and within rating over the entire speed range. The laboratory measurements allowed the speed-sensitive losses to be quantified and incorporated into computer simulation models, which then accurately reproduce the results of lab testing. The simulator shows that the limiting CPSR of the test motor is 8:1. These results confirm that the DMIC is capable of driving low-inductance BDCMs over the wide CPSR that would be required in electric vehicle applications.« less

  5. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    PubMed

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. 13C-Mixed Triglyceride Breath Test and Fecal Elastase as an Indirect Pancreatic Function Test in Cystic Fibrosis Infants.

    PubMed

    Kent, Dorothea Stark; Remer, Thomas; Blumenthal, Caron; Hunt, Sharon; Simonds, Sharon; Egert, Sarah; Gaskin, Kevin J

    2018-05-01

    The 'gold standard' test for the indirect determination of pancreatic function status in infants with cystic fibrosis (CF), the 72-hour fecal fat excretion test, is likely to become obsolete in the near future. Alternative indirect pancreatic function tests with sufficient sensitivity and specificity to determine pancreatic phenotype need further evaluation in CF infants. Evaluation of the clinical utility of both the noninvasive, nonradioactive C-mixed triglyceride (MTG) breath test and fecal elastase-1 (FE1) in comparison with the 72-hour fecal fat assessment in infants with CF. C-MTG breath test and the monoclonal and polyclonal FE1 assessment in stool was compared with the 72-hour fecal fat assessment in 24 infants with CF. Oral pancreatic enzyme substitution (PERT; if already commenced) was stopped before the tests. Sensitivity rates between 82% and 100% for CF patients with pancreatic insufficiency assessed by both the C-MTG breath test and the FE1 tests proved to be high and promising. The C-MTG breath test (31%-38%) as well as both FE1 tests assessed by the monoclonal (46%-54%) and the polyclonal (45%) ELISA kits, however, showed unacceptably low-sensitivity rates for the detection of pancreatic-sufficient CF patients in the present study. The C-MTG breath test with nondispersive infrared spectroscopy (NDIRS) technique, as well as both FE1 tests, are not alternatives to the fecal fat balance test for the evaluation of pancreatic function in CF infants during the first year of life.

  7. An experimental study of the sensitivity of helicopter rotor blade tracking to root pitch adjustment in hover

    NASA Technical Reports Server (NTRS)

    Wilkie, W. Keats; Langston, Chester W.; Mirick, Paul H.; Singleton, Jeffrey D.; Wilbur, Matthew L.; Yeager, William T., Jr.

    1991-01-01

    The sensitivity of blade tracking in hover to variations in root pitch was examined for two rotor configurations. Tests were conducted using a four bladed articulated rotor mounted on the NASA-Army aeroelastic rotor experimental system (ARES). Two rotor configurations were tested: one consisting of a blade set with flexible fiberglass spars and one with stiffer (by a factor of five in flapwise and torsional stiffnesses) aluminum spars. Both blade sets were identical in planform and airfoil distribution and were untwisted. The two configurations were ballasted to the same Lock number so that a direct comparison of the tracking sensitivity to a gross change in blade stiffness could be made. Experimental results show no large differences between the two sets of blades in the sensitivity of the blade tracking to root pitch adjustments. However, a measurable reduction in intrack coning of the fiberglass spar blades with respect to the aluminum blades is noted at higher rotor thrust conditions.

  8. Parameter regionalization of a monthly water balance model for the conterminous United States

    USGS Publications Warehouse

    Bock, Andrew R.; Hay, Lauren E.; McCabe, Gregory J.; Markstrom, Steven L.; Atkinson, R. Dwight

    2016-01-01

    A parameter regionalization scheme to transfer parameter values from gaged to ungaged areas for a monthly water balance model (MWBM) was developed and tested for the conterminous United States (CONUS). The Fourier Amplitude Sensitivity Test, a global-sensitivity algorithm, was implemented on a MWBM to generate parameter sensitivities on a set of 109 951 hydrologic response units (HRUs) across the CONUS. The HRUs were grouped into 110 calibration regions based on similar parameter sensitivities. Subsequently, measured runoff from 1575 streamgages within the calibration regions were used to calibrate the MWBM parameters to produce parameter sets for each calibration region. Measured and simulated runoff at the 1575 streamgages showed good correspondence for the majority of the CONUS, with a median computed Nash–Sutcliffe efficiency coefficient of 0.76 over all streamgages. These methods maximize the use of available runoff information, resulting in a calibrated CONUS-wide application of the MWBM suitable for providing estimates of water availability at the HRU resolution for both gaged and ungaged areas of the CONUS.

  9. Parameter regionalization of a monthly water balance model for the conterminous United States

    NASA Astrophysics Data System (ADS)

    Bock, Andrew R.; Hay, Lauren E.; McCabe, Gregory J.; Markstrom, Steven L.; Atkinson, R. Dwight

    2016-07-01

    A parameter regionalization scheme to transfer parameter values from gaged to ungaged areas for a monthly water balance model (MWBM) was developed and tested for the conterminous United States (CONUS). The Fourier Amplitude Sensitivity Test, a global-sensitivity algorithm, was implemented on a MWBM to generate parameter sensitivities on a set of 109 951 hydrologic response units (HRUs) across the CONUS. The HRUs were grouped into 110 calibration regions based on similar parameter sensitivities. Subsequently, measured runoff from 1575 streamgages within the calibration regions were used to calibrate the MWBM parameters to produce parameter sets for each calibration region. Measured and simulated runoff at the 1575 streamgages showed good correspondence for the majority of the CONUS, with a median computed Nash-Sutcliffe efficiency coefficient of 0.76 over all streamgages. These methods maximize the use of available runoff information, resulting in a calibrated CONUS-wide application of the MWBM suitable for providing estimates of water availability at the HRU resolution for both gaged and ungaged areas of the CONUS.

  10. Stability and delay sensitivity of neutral fractional-delay systems.

    PubMed

    Xu, Qi; Shi, Min; Wang, Zaihua

    2016-08-01

    This paper generalizes the stability test method via integral estimation for integer-order neutral time-delay systems to neutral fractional-delay systems. The key step in stability test is the calculation of the number of unstable characteristic roots that is described by a definite integral over an interval from zero to a sufficient large upper limit. Algorithms for correctly estimating the upper limits of the integral are given in two concise ways, parameter dependent or independent. A special feature of the proposed method is that it judges the stability of fractional-delay systems simply by using rough integral estimation. Meanwhile, the paper shows that for some neutral fractional-delay systems, the stability is extremely sensitive to the change of time delays. Examples are given for demonstrating the proposed method as well as the delay sensitivity.

  11. [Visual function evaluation in human immunodeficiency virus carriers].

    PubMed

    Solís-Castillo, A; Ramírez-Ponce, L A; Valdez-González, T; Seijo, E; Voorduin-Ramos, S; López-Star, E M

    2011-04-01

    To determine whether there are changes in the peripapillary nerve fibre layer, in colour vision, contrast sensitivity, dark adaptation and electroretinography changes in these patients who do not have infectious retinitis. We studied 52 patients without ocular pathology; the mean age was 35.88 years old. We observed less thickness in all quadrants, except the nasal. The colour vision was altered in 27.77% of the patients. The contrast sensitivity test showed high frequency alterations. There was no statistically significant difference in the electroretinography test or in dark adaptation. There are changes in the peripapillary nerve fibre layer thickness; also we found changes in colour vision, contrast sensitivity and a decreasing trend of the B wave in the electroreninogram. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  12. In Vitro Sensitivity of Cutaneous Leishmania Promastigote Isolates Circulating in French Guiana to a Set of Drugs

    PubMed Central

    Ginouvès, Marine; Simon, Stéphane; Nacher, Mathieu; Demar, Magalie; Carme, Bernard; Couppié, Pierre; Prévot, Ghislaine

    2017-01-01

    Anti-leishmaniasis drug resistance is a common problem worldwide. The aim of this study was to inventory the general in vitro level of sensitivity of Leishmania isolates circulating in French Guiana and to highlight potential in vitro pentamidine-resistant isolates. This sensitivity study was conducted on 36 patient-promastigote isolates for seven drugs (amphotericin B, azithromycin, fluconazole, meglumine antimoniate, miltefosine, paromomycin, and pentamidine) using the Cell Counting Kit-8 viability test. The IC50 values obtained were heterogeneous. One isolate exhibited high IC50 values for almost all drugs tested. Pentamidine, which is the first-line treatment in French Guiana, showed efficacy at very low doses (mean of 0.0038 μg/mL). The concordance of the in vitro pentamidine results with the patients' clinical outcomes was 94% (K = 0.82). PMID:28167598

  13. Sensitivity and specificity of modified 100-g oral glucose tolerance tests for diagnosis of gestational diabetes mellitus.

    PubMed

    Hansarikit, Jarunee; Manotaya, Saknan

    2011-05-01

    To study the sensitivity and specificity of the modified 100-g oral glucose tolerance test for diagnosis of gestational diabetes mellitus (GDM). Medical records of pregnant women attending the antenatal clinic of King Chulalongkorn Memorial Hospital, Thailand, who underwent a 100-g oral glucose tolerance test (OGTT) during March 2004 to September 2009, were retrospectively reviewed. Three modified criteria were proposed for diagnosis of GDM. The screening efficacy of the modified criteria were assessed, using the National Diabetes Data Group (NDDG) criterion as gold standard. A total of 729 records were reviewed, 511 were included for analysis. Using the NDDG criterion as the gold standard, the modified II criterion has the highest sensitivity of 96.8%, and the highest accuracy of 90.8%. The modified II criterion can detect the same proportion of maternal and neonatal complications, compared to the NDDG criterion. The modified II criterion, using the fasting plasma glucose and 2-hour plasma glucose measurements, showed high sensitivity and accuracy, with moderate specificity for diagnosis of GDM. Its potential use as an alternative to standard 100-g OGTT should be evaluated in the prospective study.

  14. Sensitized Liquid Hydrazine Detonation Studies

    NASA Technical Reports Server (NTRS)

    Rathgeber, K. A.; Keddy, C. P.; Bunker, R. L.

    1999-01-01

    Vapor-phase hydrazine (N2H4) is known to be very sensitive to detonation while liquid hydrazine is very insensitive to detonation, theoretically requiring extremely high pressures to induce initiation. A review of literature on solid and liquid explosives shows that when pure explosive substances are infiltrated with gas cavities, voids, and/or different phase contaminants, the energy or shock pressure necessary to induce detonation can decrease by an order of magnitude. Tests were conducted with liquid hydrazine in a modified card-gap configuration. Sensitization was attempted by bubbling helium gas through and/or suspending ceramic microspheres in the liquid. The hydrazine was subjected to the shock pressure from a 2 lb (0.9 kg) Composition C-4 explosive charge. The hydrazine was contained in a 4 in. (10.2 cm) diameter stainless steel cylinder with a 122 in(sup 3) (2 L) volume and sealed with a polyethylene cap. Blast pressures from the events were recorded by 63 high speed pressure transducers located on three radial legs extending from 4 to 115 ft (1.2 to 35.1 in) from ground zero. Comparison of the neat hydrazine and water baseline tests with the "sensitized" hydrazine tests indicates the liquid hydrazine did not detonate under these conditions.

  15. Effects of an educational programme on shared decision-making among Korean nurses.

    PubMed

    Jo, Kae-Hwa; An, Gyeong-Ju

    2015-12-01

    This study was conducted to examine the effects of an educational programme on shared decision-making on end-of-life care performance, moral sensitivity and attitude towards shared decision-making among Korean nurses. A quasi-experimental study with a non-equivalent control group pretest-posttest design was used. Forty-one clinical nurses were recruited as participants from two different university hospitals located in Daegu, Korea. Twenty nurses in the control group received no intervention, and 21 nurses in the experimental group received the educational programme on shared decision-making. Data were collected with a questionnaire covering end-of-life care performance, moral sensitivity and attitude towards shared decision-making. Analysis of the data was done with the chi-square test, t-test and Fisher's exact test using SPSS/Win 17.0 (SPSS, Inc., Chicago, IL, USA). The experimental group showed significantly higher scores in moral sensitivity and attitude towards shared decision-making after the intervention compared with the control group. This study suggests that the educational programme on shared decision-making was effective in increasing the moral sensitivity and attitude towards shared decision-making among Korean nurses. © 2014 Wiley Publishing Asia Pty Ltd.

  16. Overcoming pain thresholds with multilevel models-an example using quantitative sensory testing (QST) data.

    PubMed

    Hirschfeld, Gerrit; Blankenburg, Markus R; Süß, Moritz; Zernikow, Boris

    2015-01-01

    The assessment of somatosensory function is a cornerstone of research and clinical practice in neurology. Recent initiatives have developed novel protocols for quantitative sensory testing (QST). Application of these methods led to intriguing findings, such as the presence lower pain-thresholds in healthy children compared to healthy adolescents. In this article, we (re-) introduce the basic concepts of signal detection theory (SDT) as a method to investigate such differences in somatosensory function in detail. SDT describes participants' responses according to two parameters, sensitivity and response-bias. Sensitivity refers to individuals' ability to discriminate between painful and non-painful stimulations. Response-bias refers to individuals' criterion for giving a "painful" response. We describe how multilevel models can be used to estimate these parameters and to overcome central critiques of these methods. To provide an example we apply these methods to data from the mechanical pain sensitivity test of the QST protocol. The results show that adolescents are more sensitive to mechanical pain and contradict the idea that younger children simply use more lenient criteria to report pain. Overall, we hope that the wider use of multilevel modeling to describe somatosensory functioning may advance neurology research and practice.

  17. Semi-continuous ultrasonic sounding and changes of ultrasonic signal characteristics as a sensitive tool for the evaluation of ongoing microstructural changes of experimental mortar bars tested for their ASR potential.

    PubMed

    Lokajíček, T; Kuchařová, A; Petružálek, M; Šachlová, Š; Svitek, T; Přikryl, R

    2016-09-01

    Semi-continuous ultrasonic sounding of experimental mortar bars used in the accelerated alkali silica reactivity laboratory test (ASTM C1260) is proposed as a supplementary measurement technique providing data that are highly sensitive to minor changes in the microstructure of hardening/deteriorating concrete mixture. A newly designed, patent pending, heating chamber was constructed allowing ultrasonic sounding of mortar bars, stored in accelerating solution without necessity to remove the test specimens from the bath during the measurement. Subsequent automatic data analysis of recorded ultrasonic signals proved their high correlation to the measured length changes (expansion) and their high sensitivity to microstructural changes. The changes of P-wave velocity, and of the energy, amplitude, and frequency of ultrasonic signal, were in the range of 10-80%, compared to 0.51% change of the length. Results presented in this study thus show that ultrasonic sounding seems to be more sensitive to microstructural changes due to ongoing deterioration of concrete microstructure by alkali-silica reaction than the dimensional changes. Copyright © 2016. Published by Elsevier B.V.

  18. Inhibitory masking controls the threshold sensitivity of retinal ganglion cells

    PubMed Central

    Pan, Feng; Toychiev, Abduqodir; Zhang, Yi; Atlasz, Tamas; Ramakrishnan, Hariharasubramanian; Roy, Kaushambi; Völgyi, Béla; Akopian, Abram

    2016-01-01

    Key points Retinal ganglion cells (RGCs) in dark‐adapted retinas show a range of threshold sensitivities spanning ∼3 log units of illuminance.Here, we show that the different threshold sensitivities of RGCs reflect an inhibitory mechanism that masks inputs from certain rod pathways.The masking inhibition is subserved by GABAC receptors, probably on bipolar cell axon terminals.The GABAergic masking inhibition appears independent of dopaminergic circuitry that has been shown also to affect RGC sensitivity.The results indicate a novel mechanism whereby inhibition controls the sensitivity of different cohorts of RGCs. This can limit and thereby ensure that appropriate signals are carried centrally in scotopic conditions when sensitivity rather than acuity is crucial. Abstract The responses of rod photoreceptors, which subserve dim light vision, are carried through the retina by three independent pathways. These pathways carry signals with largely different sensitivities. Retinal ganglion cells (RGCs), the output neurons of the retina, show a wide range of sensitivities in the same dark‐adapted conditions, suggesting a divergence of the rod pathways. However, this organization is not supported by the known synaptic morphology of the retina. Here, we tested an alternative idea that the rod pathways converge onto single RGCs, but inhibitory circuits selectively mask signals so that one pathway predominates. Indeed, we found that application of GABA receptor blockers increased the sensitivity of most RGCs by unmasking rod signals, which were suppressed. Our results indicate that inhibition controls the threshold responses of RGCs under dim ambient light. This mechanism can ensure that appropriate signals cross the bottleneck of the optic nerve in changing stimulus conditions. PMID:27350405

  19. The Abbott RealTime High Risk HPV test is a clinically validated human papillomavirus assay for triage in the referral population and use in primary cervical cancer screening in women 30 years and older: a review of validation studies.

    PubMed

    Poljak, Mario; Oštrbenk, Anja

    2013-01-01

    Human papillomavirus (HPV) testing has become an essential part of current clinical practice in the management of cervical cancer and precancerous lesions. We reviewed the most important validation studies of a next-generation real-time polymerase chain reaction-based assay, the RealTime High Risk HPV test (RealTime)(Abbott Molecular, Des Plaines, IL, USA), for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older published in peer-reviewed journals from 2009 to 2013. RealTime is designed to detect 14 high-risk HPV genotypes with concurrent distinction of HPV-16 and HPV-18 from 12 other HPV genotypes. The test was launched on the European market in January 2009 and is currently used in many laboratories worldwide for routine detection of HPV. We concisely reviewed validation studies of a next-generation real-time polymerase chain reaction (PCR)-based assay: the Abbott RealTime High Risk HPV test. Eight validation studies of RealTime in referral settings showed its consistently high absolute clinical sensitivity for both CIN2+ (range 88.3-100%) and CIN3+ (range 93.0-100%), as well as comparative clinical sensitivity relative to the currently most widely used HPV test: the Qiagen/Digene Hybrid Capture 2 HPV DNA Test (HC2). Due to the significantly different composition of the referral populations, RealTime absolute clinical specificity for CIN2+ and CIN3+ varied greatly across studies, but was comparable relative to HC2. Four validation studies of RealTime performance in cervical cancer screening settings showed its consistently high absolute clinical sensitivity for both CIN2+ and CIN3+, as well as comparative clinical sensitivity and specificity relative to HC2 and GP5+/6+ PCR. RealTime has been extensively evaluated in the last 4 years. RealTime can be considered clinically validated for triage in referral population settings and for use in primary cervical cancer screening in women 30 years and older.

  20. Diagnostic Performance of a Molecular Test versus Clinician Assessment of Vaginitis.

    PubMed

    Schwebke, Jane R; Gaydos, Charlotte A; Nyirjesy, Paul; Paradis, Sonia; Kodsi, Salma; Cooper, Charles K

    2018-06-01

    Vaginitis is a common complaint, diagnosed either empirically or using Amsel's criteria and wet mount microscopy. This study sought to determine characteristics of an investigational test (a molecular test for vaginitis), compared to reference, for detection of bacterial vaginosis, Candida spp., and Trichomonas vaginalis Vaginal specimens from a cross-sectional study were obtained from 1,740 women (≥18 years old), with vaginitis symptoms, during routine clinic visits (across 10 sites in the United States). Specimens were analyzed using a commercial PCR/fluorogenic probe-based investigational test that detects bacterial vaginosis, Candida spp., and Trichomonas vaginalis Clinician diagnosis and in-clinic testing (Amsel's test, potassium hydroxide preparation, and wet mount) were also employed to detect the three vaginitis causes. All testing methods were compared to the respective reference methods (Nugent Gram stain for bacterial vaginosis, detection of the Candida gene its2 , and Trichomonas vaginalis culture). The investigational test, clinician diagnosis, and in-clinic testing were compared to reference methods for bacterial vaginosis, Candida spp., and Trichomonas vaginalis The investigational test resulted in significantly higher sensitivity and negative predictive value than clinician diagnosis or in-clinic testing. In addition, the investigational test showed a statistically higher overall percent agreement with each of the three reference methods than did clinician diagnosis or in-clinic testing. The investigational test showed significantly higher sensitivity for detecting vaginitis, involving more than one cause, than did clinician diagnosis. Taken together, these results suggest that a molecular investigational test can facilitate accurate detection of vaginitis. Copyright © 2018 Schwebke et al.

Top